PRU Installation - ClassicUse this method if you are going to use the standard installation technique.1. Plug in the PRU+: Plug one end of the AC Adapter into a 110 Volt AC Outlet and the otherend into the PRU+.  The PRU+ will turn on, displaying the title screen.  It will then display thedate and time screen.  The power and charge LED will be lit.  The charge LED will go out whenthe unit is fully charged.2. Clear Stored Events: Press and hold the         PRU+ button on the LOCK until the PRU+prompts “Please Wait....”.  When the display prompts “B=Function Mode” press B button once.The display will prompt “B=Clear Events”. Press B to clear all stored events.  The display willread “Events cleared”.3. Test for RF Signal Strength:  Press “A” button twice.  When the display prompts “B=TestMode”, press the “B” button to enter Test Mode.  Look at the top line marked “RFStr”. Thedisplay will have a value on the top line that indicates thesignal strength of the last transmission of the PIDdisplayed.  Thevalue is arepresentationof the distancethe PID islocated awayfrom the PRU+.To reduce therange the PRU+will monitor theparticipant set the RSSI setting in Extended Special Function Mode to this value minus 15%(approx 30 points).  Note: setting this value higher will reduce the size of the area ofconfinement..PID Installation5. Install the Battery:  Remove the PID , baseplate, one strap, one locking bar, one locking pinand the battery from the case.  Simply place the battery into the PID battery well so that thealignment mark on the battery lines up with the alignment mark on the PID. Rotate the batterycounterclockwise until the tabs on the battery slide under the two lock down posts. (See Figure3 : installing the battery in the PID).Figure 3: Installing the battery in the PID6. Size the Strap:  Attach the wide end of the strap to the PID baseplate.  With the baseplate onthe outside of the leg, wrap the strap around the participants leg, just above the ankle. Size the
strap so that it fits comfortably around the participant’s leg.  Cut off any access strap that isabove the two hole positions that will fit into the other side of the strap (See Figure 4 : Strapinstallation)Figure 4 : Strap Installation7. Install Strap and PID:Replace the baseplate and straparound the leg, and attach the narrow end that has been cut tolength to the baseplate.  Push the PID onto the baseplate at thestrap end. The PID is now hinged to the baseplate.  Firmly close the PID and baseplatetogether by pushing down on the open end.Figure 5 : Attach the PID to the baseplate8. Install Locking Mechanism: Insert the slider bar under the strap into the hole in the side ofthe PID (See Figure 6 : Slider Bar) so the end ofthe  slider  bar  is flush with the strap.  Press apin through the hole in the strap and into the sliderbar.  This locks the PID together.Figure 6 : Slider Bar
9. Check Strap Tightness: Check the strap tightness on the side opposite the PID.  Thereshould not be a space of more than ½ inch or 1.4 centimetres between the strap and the skin.Installation Completion10. Test the PID Signal:  Watch the PRU+ in test mode, to ensure that the signal from the  PID isbeing received.  The PID code number will be displayed and the PRU+ will beep to indicate ithas received the signal from the assigned PID.  Note: during the first 5 seconds after the PRU+receives the signal there will be a “+” immediately in front of the PID number. This willdisappear after 5 seconds.  If the PID signal is not received within 1 minute, remove the PIDand check that the battery is properly installed.11. Reset the PID:  When a signal has been received by the PRU+, use the LOCK’s         PIDbutton to reset the alarms on the PID.  Wait until the next signal from the PID.  If the alarms hasbeen properly reset, the PID number will be displayed, with no icons following it.12. Complete the Installation: On the PRU+, press the A button until “B=Exit” is displayed.  Pressbutton B to exit.  Connect the phone line to the wall and to the “LINE” jack on the PRU+.  ThePRU+ will call the Central Computer.  When “Call Successful” is displayed, remove thetelephone cable from the PRU+.  Leave the AC Power adapter attached to the PRU+ butunplug it from the wall outlet.  The PRU+ can now be placed inside the participant’s home.13. Position the PRU+: Remove the PRU+ and AC Adapter.  Place the PRU+ in a centrallocation, preferably closer to the participant’s bedroom than their living area, elevated at leastthree feet / ninety centimetres from the floor.  Assure that the PRU+ is plugged into AC powerwhen it reaches the participant’s home (be careful that the AC outlet that the PRU+ is pluggedinto cannot be switched off with a light switch).Downloading Information inside the PRU+1. Connect AC:  The information inside the PRU+ should be regularly downloaded (ie once perweek / once every two weeks).  Connect the AC adapter to a wall outlet.2. Connect Telephone:  Connect the telephone cable to the telephone outlet.  The PRU+ shouldimmediately start to call the central computer.3. Wait for “Call Successful”:  The PRU+ should indicate “Call Successful” when the PRU+ hastransferred all of the stored information.  If the PRU+ does not indicate “Call Successful” thePRU+ needs to call into the CC again.  This can most easily be accomplished by removing theAC plug from the wall until the PRU+ indicates “Starting Call..”.  Once the PRU+ indicates“Telephone In Use” plug the AC adapter back into the wall outlet.De-Installation / RemovalA.  If your equipment is monitored by our Monitoring Center:-- Fax the Inactivation Form to the Monitoring Center on the same day that the unit is to beremoved from the participant’s residence.B. If you monitor your own equipment:-- Assure the participant ‘s sentence ends on the same day that the unit is removed from theparticipant’s residence.
1. Connect AC Power & Telephone: Connect AC Power to the PRU+ by plugging the ACadapter into a wall outlet.  Connect the telephone into the telephone outlet.  The PRU+ shouldimmediately start to call into the central computer.2. Wait for “Call Successful”: When the PRU+ indicates “Call Successful” the PRU+ hastransferred all of the stored information.  If the PRU+ does not indicate “Call Successful” thePRU+ needs to call into the CC again.  This can most easily be accomplished by removing theAC plug from the wall until the PRU+ indicates “Starting Call..”.  Once the PRU+ indicates“Telephone In Use” plug the AC adapter back into the wall outlet.3. Turn the PRU+ Off: Press and hold the         PRU+ button on the LOCK until “Please Wait...”Is displayed on the PRU+.  When “A=Turn PRU+ Off” is displayed, press button A on the PRU.Disconnect the AC adapter from the wall.  The PRU+ will turn off in approximately five (5)seconds.4. Disconnect the PRU+: Disconnect the AC adapter from the back of the PRU+.  Disconnectthe telephone cord from the PRU+ and wall jack.  Place the PRU+, AC Adapter and telephonecord into the carry / storage case.5. Remove the Pin and Slider Bar:  Using a tool such as a small screwdriver, rotate the lockingpin on the PID all the way around two times (in both directions). This will break the locking pinand will enable the slider bar to be removed.6. Remove the PID from the Baseplate:  Remove the locking pin and slider bar.  At the sliderbar end, lift the PID away from the baseplate (like opening a clam shell).7. Remove the Battery: Remove the battery from the PID by pulling it out of the battery well andplace it in the plastic container in the carry / storage case.  DO NOT TRY TO TURN THEBATTERY.8. Remove the Strap:  Remove the strap from the baseplate.  Replace the baseplate back ontothe PID and return the PID to the carry / storage case.
STRATEGIC Technologies Inc. Domestic ViolenceDomestic ViolenceUnfortunately, issuing restraining orders does not assure safety to domestic violence victims.Courts and law enforcement agencies enforcing  stalking and domestic violence restraining ordersrequire assistance which the Platinum Plus 400 Series can supply.  The offender, wearing atransmitter, can continue to function in the community while complying to the restraining order. ThePersonal Identification Device (transmitter) will act as a deterrent to the offender by enforcing therealization they cannot approach the victim without activating an alarm.  The victim is offered ameasure of security in that if the offender comes too close to their residence a priority alarm will besounded and there is a link to authority for immediate help.The victim is given a Panic Alarm Pendant, and a PRU+ is installed in their place of residence.  ThePersonal Identification Device is worn by the offender.  Another PRU+ should be installed at theoffender’s residence to enforce compliance with a curfew schedule and ensure that the offenderhas not tampered or removed the transmitter. The information is entered into the central computer,and is flagged as a priority domestic violence case.The Panic Alarm Pendant transmitter code is programmed into the spousal code in the PRU+ andthe offenders PID code is programmed into the regular PID code (See Extended Special FunctionMode on page 38 For more information about programming these numbers).  This will enable thePRU+ to differentiate between a transmission sent by the pendant and the PID worn by theoffender.
STRATEGIC Technologies Inc. Domestic Violence InstallationDomestic Violence InstallationVictims InstallationPre-InstallationA. If your equipment is monitored by our Monitoring Center:-- Fax the Enrollment Form to the Monitoring Center, giving as much time as possible (½hour minimum) before the unit is to be hooked up inside the victims home.  The MonitoringCenter  must be notified before the unit calls in. The form should be clearly markedindicating this unit is a domestic violence unit and is located in the victims home.B.  If you monitor your own equipment:-- Assure you have entered the victims data on your system before you install the unit in theoffenders home. The curfew schedule should be entered with AWAY time all day. SeePage 50 For a complete listing of all events generated by the PRU+.PRU+ Installation1.  Position the PRU+:  Remove the PRU+ and AC power adapter from the case.  Place thePRU+ in a central location, preferably closer to the participant’s bedroom than their living area,elevated at least three feet / ninety centimetres from the floor.2. Plug in the PRU+:  Plug one end of the AC power adapter into a standard 110 Volt electricaloutlet and the other end into the PRU+.  Note : Do not connect the telephone line. ThePRU+ will turn on, displaying the title screen.  It will then display the date and time screen.  Thepower and charge LED will be lit.  The charge LED will go out when the PRU+ internal batteryis fully charged.3. Clear Stored Events:  Press and hold the         PRU+ button on the LOCK until the PRU+prompts  “Please Wait....”.    When the display prompts “B=Function Mode” press “B” buttononce.   The display will prompt  “B=Clear Events”.  Press “B”, the display will now prompt “A=**Clear ** / B=Cancel”.  Press “A”  to clear all events.Transmission ChecksCheck the Participant’s PIDAt this time, the PID that will monitor the offender should also be checked.  This will verify that thesystem operates correctly.5. Install the Battery:  Remove the PID , baseplate, one strap, one locking bar, one locking pinand the battery from the case.  Simply place the battery into the PID battery well so that thealignment mark on the battery lines up with the alignment mark on the PID. Rotate the batterycounterclockwise until the tabs on the battery slide under the two lock down posts. (See Figure3 : installing the battery in the PID).
STRATEGIC Technologies Inc. Domestic Violence InstallationFigure 3: Installing the battery in the PID6.  Check PID Transmission: Press A twice then hit B to go into Test Mode.  Hold the PID andwatch the PRU+ Test Mode Screen for a transmission from the PID.  When the signal isreceived it should indicate strap sever        symbol.  The PRU+ should also beep to indicatethe PID has the correct code.  When the transmission is received remove the battery by liftingthe battery out of the battery recess in the PID and place it in the plastic container in theoffenders carry / storage case.Check the Pendant7.  Check the Pendant Transmission: Push both pendant buttons.  The Test Mode screen shouldindicate a new transmission (with the code matching the pendant) by placing a + to the left ofthe code.Installation Completion8. Complete the Installation: On the PRU+, press the A button until “B=Exit” is displayed.  Pressbutton B to exit.  Connect the phone line to the wall and to the “LINE” jack on the PRU+.  ThePRU+ will call the Central Computer.  When “Call Successful” is displayed, installation iscomplete.9. Install the offender’s unit: Follow the PRU+ Active Mode Installation instructions (Page 17,44) for installing the PRU+ / PID set on the offender.
STRATEGIC Technologies Inc. Domestic Violence InstallationDe-Installation / RemovalA.  If your equipment is monitored by our Monitoring Center:-- Fax the Inactivation Form to the Monitoring Center on the same day that the unit is to beremoved from the offender’s residence.B.  If you monitor your own equipment:-- Assure the offender ‘s sentence ends on the same day that the unit is removed from thevictim’s residence.1. Disconnect the PRU+: Disconnect the telephone cord from the PRU+ and wall jack.Disconnect the AC adapter from the back of the PRU+2. Turn the PRU+ Off: Press and hold the         PRU+ button on the LOCK until “Please Wait...”Is displayed on the PRU+.  When “A=Turn PRU+ Off” is displayed, press button A on thePRU+.  Disconnect the AC adapter from the wall.  The PRU+ will turn off in approximately fiveseconds.3.  Place in storage case: Place the PRU+, Pendant, AC adapter and telephone cord into the carry /storage case.
STRATEGIC Technologies Inc. Special Function ModeSpecial Function ModeThe PRU+'s Special Function Mode allows the installer to change various configuration settings,clear the stored events, and enter a test / diagnostic mode. To enter the Special Function Mode,you use the LOCK.  Simply press the           PRU+ button on the LOCK, while holding the LOCKwithin three feet (1 metre) of the PRU+.  The front panel display will show the message "PleaseWait....", and will then display two choices: "A=Turn PRU+ Off" and "B=Function Mode", as shownbelow.The PRU+ can be turned off by pressing the “A” button on the front display of the PRU+.  Pressingthe "B" button will enter function mode.  The first function mode screen is displayed, as shownbelow.Press the "B" button to clear all stored events in the PRU+'s memory. The display will prompt “A=**Clear **”; press “A”  to clear events.  The message "Events Cleared!" will be displayed briefly.Press the "A" button to move to the next screen.Press “B” to enter the Quick Install function.  Please refer to Quick Install on Page 44 for moreinformation.  Press “A” to move to the next screenPress the "B" button to enter Test Mode. Please refer to the section titled "Test Mode" on page 42.Press the "A" button to move to the next screen.This screen concludes the first set of program options. At this point, pressing the "B" button causesthe PRU+ to exit Special Function Mode and begin normal operation.  Pressing the "A" buttonreturns the installer to the first screen (A=Turn PRU+ Off / B=Function Mode).A-Turn PRU+ OffB-Function ModeA=Next FunctionB=Clear EventsA=Next FunctionB=Quick InstallA=Next FunctionB=Test ModeA=Next FunctionB=EXIT
STRATEGIC Technologies Inc. Extended Special Function ModeExtended Special Function ModeExtended Special Function Mode is used to change the internal settings inside the PRU+.  Theability to change the internal settings gives the PRU+ great flexibility.  The installer can now changeimportant settings depending upon their needs.Extended Special Function Mode can be accessed by moving to the screen “B=Exit” as shown onpages 36 and 37.  To access the extended configuration settings, hold down the         PRU buttonon the LOCK. Once a small dot begins to flash in the right top corner of the display press the "A"button.  This will cause the PRU+ to display the configuration screen, as shown in the next diagram.This screen allow the installer to change the way the PRU+ dials.  The PRU+ can dial both pulseand tone.  Select the mode that is appropriate for your telephone network.  Press the “B” button tochange the dial mode between “T” (tone dialling) and “P” (pulse dialling).  Press the “A” button tomove to the next screen.If the PRU+ is installed in an office or a hotel,  the telephone system may require an additional digitto be dialled to access an outside line.  Pressing the “B” button changes the prefix between “N”which indicates “No Prefix” required to a “digit” from  0 to 9.   Stop pressing the “B” button when theprefix required is reached.   Press “A” button to proceed to the next function.This screen allows the installer to change the telephone number that the PRU+ will dial to call theCentral Computer.  When this screen is displayed, pressing the "A" button will move to the nextscreen. If the "B" button is pressed, a flashing cursor is displayed over the first character of thetelephone number. This indicates that the display is now in "edit mode". While in edit mode,pressing the "B" button will change the character under the cursor. Pressing the "B" buttonrepeatedly will cycle through the valid characters (0-9, a # symbol, a * symbol, a comma - used toinsert a two-second pause into the dialling sequence; or a space - to erase unnecessarycharacters). While in the edit mode, pressing the "A" button steps through the character positionsfrom left to right, until the last (fourteenth) character is reached. At this point, pressing the "A" buttonwill cause the screen to exit “edit mode” and move to the next option.A=Next FunctionB=Dial Mode        TA=Next FunctionB=Dial Prefix: NA=Next FunctionB#1,8001231234
STRATEGIC Technologies Inc. Extended Special Function ModeThis screen enables the installer to limit the range the PRU+ will detect the presence of the PID. Iftransmissions are received from the PID with a signal strength less than the value set thetransmission will be ignored.  The value may be set between 0 - 255.  A value of 0 indicates alltransmissions will be valid.  To set the value press B and a cursor will appear under the first digit ofthe setting.  Press B to increment the current digit and press A to move to the next digit.This screen allows the installer to change the number of the PID installed on the participant. This isuseful for cases where the supplied PID has been lost or broken, and a replacement PID with adifferent code must be used. This screen operates similarly to the telephone number screen. Whenthis screen is displayed, pressing the "A" button will move to the next screen. If the "B" button ispressed, a flashing cursor is displayed over the first character of the PID code. This indicates thatthe display is now in "edit mode". While in “edit mode”, pressing the "B" button will change thenumber under the cursor. Pressing the "B" button repeatedly will cycle the digit under the cursorfrom 0 to 9. NOTE: code numbers such as "68" must be entered as "068". While in the edit mode,pressing the "A" button steps through the digits from left to right, until the third digit is reached. Atthis point, pressing the "A" button causes the screen to exit “edit mode” and move to the nextoption.This screen allows the installer to change the leave window for the PRU+.  The leave window is theperiod of time which the PRU+ allows to elapse without receipt of any transmissions from the PIDbefore a "Leave" message (ie ..info leave or ALARM AWAY) is registered.  Pressing the "B" buttonrepeatedly steps through the possible values (3-30). Pressing the "A" button causes the next screento be displayed.This screen allows the installer to change the code of the Domestic Violence Deterrent pendant (ifapplicable) This setting allows the PRU+ to differentiate between the transmitter worn by theoffender and the pendant used by the victim.  Different Alarm indications will be reported by thePRU+ dependant on which code is received.  See Individual Status Log Reports on Page 50 fordetailed explanations on these events.A=Next FunctionB=Set RSSI   100A=Next FunctionB=Set PID# 30431A=Next FunctionB=Set Leave 03A=Next FunctionB=SpsCode# 30253A=Next FunctionB=DateFormat YMD
STRATEGIC Technologies Inc. Extended Special Function ModeThis screen allows the installer to change the format of the date displayed by the unit during normaloperation. Pressing the "B" button repeatedly will cycle through the available options: YMD(year/month/day),  MDY (month/day/year), or DMY (day/month/year).  Press the "A" button to moveto the next screen.This screen allows the installer to change the year setting on the internal clock. Pressing the "B"button changes the year number. Pressing the "A" button causes the next screen to be displayed.NOTE: The clock is automatically updated by the Central Computer during a PRU+ call-in, to keepthe PRU+ and central computer clocks synchronized.This screen allows the installer to change the month setting on the internal clock. Pressing the "B"button changes the month number. Pressing the "A" button causes the next screen to be displayed.This screen allows the installer to change the day setting on the internal clock. Pressing the "B"button changes the day number. Pressing the "A" button causes the next screen to be displayed.This screen allows the installer to change the hour setting on the internal clock. (This is based on a24 hour clock.)  Pressing the "B" button changes the hour number. Pressing the "A" button causesthe next screen to be displayed.This screen allows the installer to change the minute setting on the internal clock. Pressing the "B"button changes the minute number. Pressing the "A" button causes the next screen to be displayed.A=Next FunctionB=Set Year   98A=Next FunctionB=Set Month 10A=Next FunctionB=Set Day    08A=Next FunctionB=Set Hour   12A=Next FunctionB=Set Min    30
STRATEGIC Technologies Inc. Extended Special Function ModeThis final screen allows the installer to exit extended special function mode. Pressing the "A" buttonreturns the installer to the very first screen (“A=Turn PRU+ Off / B=Function Mode”). Pressing the"B" button causes the PRU+ to exit Special Function Mode and resume normal mode.  All settingsare automatically saved at the time they are entered.A=Next FunctionB=EXIT
STRATEGIC Technologies Inc. Test ModeTest ModeTest Mode which is accessed from the Special Function Mode screens is useful for many diagnostictests. Selecting test mode causes the screen shown below to be displayed.Figure 1 : Test Mode DisplayThe top line of the display is the signal strength of the last transmission received from the PID alongwith the channel received.The left half of the bottom line provides PRU+ status information. The two symbols at the left edgeof the display are status indications:AC Power - indicates the AC power adapter has been properly connected andplugged into a standard functioning 110 volt AC electrical outlet.  Telephone Line  - indicates that the PRU+ has been connected to a properly functioningtelephone line.The two symbols to the right of the AC power and telephone indications represent the followingalarm conditions:PRU+ Tamper - indicates the PRU+ case is open or has been seriouslydamaged.PRU+ Motion - indicates the PRU+ is moving or tilted.Low PRU+ Battery- indicates that the PRU+'s internal battery is approaching thelimits of  sustained operation (applicable only when AC power is notconnected).The right half of the bottom line provides information on transmissions received from PIDs. The five-digit number shown is the PID code of the last received transmission (see Note below). If a '+' isshown next to the PID serial number, this indicates that the transmission was received within thelast 5 seconds.  After the + symbol expires, the position on the display will indicate if the serialnumber is assigned to either the PID monitored by the PRU+ (a ‘T’ will be displayed) or thedomestic violence pendant (an ‘S’ will be displayed).  If the        PRU+ button is pressed on theLOCK the serial number will change to display “LOCK”.
STRATEGIC Technologies Inc. Test ModeThe symbols to the right of the code number provide the following information:          PID Case Open -  indicates the last received transmission showed a case open alarm.Strap Sever - indicates the last received transmission showed a strap cut alarm.               PID Tamper - indicates the last received transmission showed a strap tamper alarm(the strap has been damaged other than being cut all the waythrough)Low PID Battery - indicates the battery installed in the PID which sent the lasttransmission is approaching the limits of its lifetime or is improperlyinstalled.NOTE: The test mode will receive and display transmissions from ALL PID's within range of thePRU+. If a transmission is received from the PID which is assigned to the PRU+, the PRU+ willbeep.
STRATEGIC Technologies Inc. Test Mode