Suprema XPS2M XPASS S2 User Manual Fingerprint Solutions of Suprema

Suprema Inc. XPASS S2 Fingerprint Solutions of Suprema

User Manual

Download: Suprema XPS2M XPASS S2 User Manual Fingerprint Solutions of Suprema
Mirror Download [FCC.gov]Suprema XPS2M XPASS S2 User Manual Fingerprint Solutions of Suprema
Document ID2324819
Application IDzB2kLsCkpIEa95IQLYKkcw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize119.79kB (1497369 bits)
Date Submitted2014-07-14 00:00:00
Date Available2014-07-14 00:00:00
Creation Date2014-07-02 11:22:15
Producing SoftwareMicrosoft® PowerPoint® 2013
Document Lastmod2014-07-09 14:29:20
Document TitleFingerprint Solutions of Suprema
Document CreatorMicrosoft® PowerPoint® 2013
Document Author: Karl

FCC TEST REPORT
Report No.: EMC-FCC-R0170
http://www.emc2000.co.kr
User Manual
EMC compliance Ltd.
65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 443-390, Korea
82-31-336-9919 (Main) 82-505-299-8311 (Fax)
This test report shall not be reproduced, except in full, Without the written approval.
Xpass S2
Intelligent IP Access Control Reader
Installation Guide
EN 101.00.XPS2 V1.00
www.supremainc.com
Xpass S2
Important Safety Information
Carefully review the information within the user manual before installing or operating the device.
Pay careful attention to the warning and cautions below as they are here to prevent any risk or damage
to any person(s) or property associated with the device.
Warning
Failure to heed these warnings may lead to serious
injury or even death!
Installation
 Do not install the device near heat sources such as radiators,
heat registers, and stoves.
 Do not install the device near areas of large electromagnetic
interference.
Usage
 Do not disassemble, repair or reconstruct the device.
Disassembling the device will void the warranty.
 Only use the device its intended use.
Contact your nearest Suprema dealer for technical support.
Caution
Failure to heed these cautions may lead to minor injury
or damage the device.
Installation
 Do not leave cables (especially power cables) exposed to
the outer environment.
 Do not install the device near objects with a strong magnetic
field such as magnets, computer monitors (especially CRT),
TV screens and speakers.
Usage
 Do not drop or apply any physical shock/impact to the device.
 Regularly clean the product with a soft dry cloth; avoid
benzene or alcohol.
ⒸCopyright 2007 Suprema Inc.
Xpass S2
Contents
Product Components
Optional Accessories
Name of Each Part
LED Status
Reset Network Settings
Product Dimension
Cables and Connectors
10
Power Connection
11
LAN Connection
12
RS485 Connection
14
Relay Connection
16
Digital Input Connection
19
Wiegand Input/Output
21
Installation of Wall-mount Bracket
22
Installation of Extended Bracket
23
Installation Reference
24
Specification
27
Electrical Specification
28
FCC Rules
29
ⒸCopyright 2007 Suprema Inc.
‹#›
Xpass S2
Product Components

Basic Components
Xpass S2
Wall Mounting Screws
(2 ea)
Wall Bracket
Screw Anchors
(2 ea)
Shrinkable Tubes
Software CD
Diode
(1 ea)
The components used above may differ depending on the installation environment.
ⒸCopyright 2007 Suprema Inc.
Xpass S2
Optional Accessories
Extended Bracket
Secure I/O
12VDC Adaptor
Plastic Stand
ⒸCopyright 2007 Suprema Inc.
Xpass S2
Name of Each Part
ⒸCopyright 2007 Suprema Inc.
Xpass S2
LED Status
LED Status by Color
Color
Sound
Description
Green
Beep x 3
Authorization Success
Red
Long Beep
Authorization Fail
Pink
Short Beep
On Processing
Flicker Blue/Skyblue Color per 2 sec
N/A
Normal
Flicker Red/Pink Color per 2 sec
N/A
Locked
Flicker Blue/Red Color per 2 sec
N/A
Initialized Time due to the
Internal Battery Discharge
Flicker Blue/Yellow Color per 2 sec
N/A
IP address is not assigned when
terminal is set as Use in the
DHCP of TCP/IP setting
For first operation, red LED is blinking
by every 2 seconds.
N/A
Failed. Please contact to your
distributor or Suprema
For normal operation, red LED is
blinking by every 2 seconds.
N/A
Security Status
N/A
Terminal is used or received a
packet to get IP address when
terminal is set as Use in the Idle
status or TCP/IP Setting
Yellow LED is blinking shortly.
ⒸCopyright 2007 Suprema Inc.
Xpass S2
Reset Network Settings
When you install the Xpass S2 or forget the network setting’s value of Xpass S2 in use, can initial the
network setting’s value (TCP/IP address, RS-485 setting) in the switch of Xpass S2’s back side as follows;
Reset Network Settings
1.
Press the Reset button located on the rear of the Xpass S2 for 3 seconds or more.
2.
Use the BioStar (Ver. 1.8 or higher) to connect to the Xpass S2 using the default
settings.
Default Network Settings:
- IP Address (Static): 192.168.0.1
- Use Server: Disabled
- RS485: PC Connection, 115200bps
3.
Enter the desired IP address or RS485 settings and save the new settings.
4.
Remove the Xpass S2 from the device list and reconnect to the device using the new network
settings.
TCP/IP Status LED


Green LED blinks shortly: Displaying connection status by TCP/IP
Red LED blinks shortly: Displaying data transfer stauts by TCP/IP
ⒸCopyright 2007 Suprema Inc.
Xpass S2
Product Dimension
< Front View >
(unit: mm)
< Side View >
< Wall Bracket >
< Extended bracket >
ⒸCopyright 2007 Suprema Inc.
Xpass S2
Cables and Connectors
1 23 4 5 6 7 8 9
Pin
Pin Name
WGD GND
SW GND
RS485 GND
WGD D0
WGD D1
SW IN0
SW IN1
RS485 TRXP
RS485 TRXN
Description
Wiegand Ground
Switch Ground
RS485 Ground
Wiegand Data 0
Wiegand Data 1
Switch Input 0
Switch Input 1
RS485 TRX+
RS485 TRX-
Color
Pin
10
11
12
13
14
15
16
17
18
Pin Name
ETH TXN
ETH TXP
ETH RXN
ETH RXP
PWR GND
RLY NO
RLY COM
RLY NC
PWR IN
Description
ETH TXN (LAN)
ETH TXP (LAN)
ETH RXN (LAN)
ETH RXP (LAN)
Power Ground
Relay Normal Open
Relay Common
Relay Normal Close
Power In
Color
1011121314 15 161718
ⒸCopyright 2007 Suprema Inc.
10
Xpass S2
Power Connection
Pin
Pin Name
Color
18
PWR IN
Red
14
PWR GND
Black (White Stripe)
18
14
Xpass S2
Recommended power supply
12VDC ± 10%, at least 300mA.
Comply with standard IEC/EN 60950-1.
To share the power with other devices, use a power supply with a higher current rating.
ⒸCopyright 2007 Suprema Inc.
11
Xpass S2
LAN Connection

Ethernet Connection (Connection with HUB)
The device can be connected to a network using a regular Ethernet hub.
ⒸCopyright 2007 Suprema Inc.
12
Xpass S2
LAN Connection (Direct connection with PC)

Ethernet Connection (Direct connection with PC)
Use a standard CAT-5 cable to connect the device directly to a PC.
ⒸCopyright 2007 Suprema Inc.
13
Xpass S2
RS485 Connection for Host Communication
Pin
Pin Name
Color
RS485 TRXP
Blue (White Stripe)
RS485 TRXN
Yellow (Black Stripe)
RS485 GND
White (Black Stripe)
Xpass S2
Xpass S2
Notes
−
−
−
Only the devices at the both ends of the bus should be terminated. To enable termination on the RS232-485 converter,
refer to the converter’s manual.
Adjust the communication speed as needed. The signal quality vary depending on wiring conditions, and it may be
necessary to lower the Baud rate.
The GND signal may be omitted if and only if the GND potential difference is less than ±5V.
ⒸCopyright 2007 Suprema Inc.
14
Xpass S2
RS485 Connection for Secure I/O
Pin
Pin Name
Color
RS485 TRXP
Blue (White Stripe)
RS485 TRXN
Yellow (Black Stripe)
RS485 GND
White (Black Stripe)
Max number of devices
Maximum eight (8) devices (including Master) interworks in an RS485 loop.
ⒸCopyright 2007 Suprema Inc.
15
Xpass S2
Relay Connection – Fail safe lock
Pin
Pin Name
Color
16
RLY COM
Green (White Stripe)
17
RLY NC
Orange (White Stripe)
16
17
Xpass S2
Take care of the direction of the diode.
Make sure to install the diode near to the door lock.
Make sure to use different power supplies for the Xpass S2 and the door lock.
Make sure to install the diode at both ends of the circuit as shown in the figure left in order
to protect the relay contact from the reverse current that occurs when the door lock works.
ⒸCopyright 2007 Suprema Inc.
16
Xpass S2
Relay Connection – Fail secure lock
Pin
Pin Name
Color
15
RLY NO
Gray (White Stripe)
16
RLY COM
Green (White Stripe)
15
16
Xpass S2
Take care of the direction of the diode.
Make sure to install the diode near to the door lock.
Make sure to use different power supplies for the Xpass S2 and the door lock.
Make sure to install the diode at both ends of the circuit as shown in the figure left in order
to protect the relay contact from the reverse current that occurs when the door lock works.
ⒸCopyright 2007 Suprema Inc.
17
Xpass S2
Relay Connection – Automatic Door
Pin
Pin Name
Color
15
RLY NO
Gray (White Stripe)
16
RLY COM
Green (White Stripe)
15
16
Xpass S2
ⒸCopyright 2007 Suprema Inc.
18
Xpass S2
Digital Input Connection (Alarm, Emergency S/W)
Pin
Pin Name
Color
SW IN1
Brown
SW GND
Gray
SW IN0
Purple
Xpass S2
ⒸCopyright 2007 Suprema Inc.
19
Xpass S2
Digital Input Connection (RTE, Door Sensor)
Pin
Pin Name
Color
SW IN1
Brown
SW GND
Gray
SW IN0
Purple
Xpass S2
ⒸCopyright 2007 Suprema Inc.
20
Xpass S2
Wiegand Input/Output

Wiegand Input
Pin
Pin Name
Color
WGD D0
Green
WGD D1
White
WGD GND
Black
Xpass S2

Wiegand Output
Pin
Pin Name
Color
WGD D0
Green
WGD D1
White
WGD GND
Black
Xpass S2
ⒸCopyright 2007 Suprema Inc.
21
Xpass S2
Installation of Wall-mount Bracket


Fix wall mount bracket on a wall
using wall mounting screws

Hook Xpass S2 on the wall mount bracket
Fix Xpass S2 to the wall mounting bracket
using a wall mounting screw
ⒸCopyright 2007 Suprema Inc.
22
Xpass S2
Installation of Extended Bracket


Assemble the extended bracket
using screws
Fix Xpass S2 and the extended
bracket using screws


Mount the extended bracket to the
desired location using screws
Hook Xpass S2 on the extended bracket
ⒸCopyright 2007 Suprema Inc.
23
Xpass S2
Installation Reference 1 - Standalone
Xpass S2
ⒸCopyright 2007 Suprema Inc.
24
Xpass S2
Installation Reference 2 – Standalone (Secure)
Xpass S2
ⒸCopyright 2007 Suprema Inc.
25
Xpass S2
Installation Reference 3 – Network
ⒸCopyright 2007 Suprema Inc.
26
Xpass S2
Specification
CPU
32-bit Microprocessor (533Mhz)
Memory
16MB Flash + 16MB SDRAM
RF Card
13.56MHz ISO14443A/B, ISO15693, Mifare, Desfire (CSN), Felica
User Capacity
50,000 users
Log Capacity
100,000 events
Interfaces
TCP/IP, RS485, Wiegand In or Out
IP Rate
IP65 dust and water protection
Sound
Multi-tone buzzer
LED
Multi-color LED
Input & Output
Relay x 1
Switch input x 2
Power
12VDC
Operating Temperature
Dimensions
Xpass S2
-35°C to 65°C
80 x 120 x 11.4mm (W x H x D)
Wall Bracket 68.4 x 110.4mm (W x H)
Certificates
CE, FCC, MSIP (KCC), IP65, RoHS, REACH, WEEE
ⒸCopyright 2007 Suprema Inc.
27
Xpass S2
Electrical Specification
Min.
Avg.
Max.
10
12
13
Notes
Power
Voltage (V)
Current (mA)
Use regulated DC power adaptor only
300
Switch Input
VIH (V)
Variable
VIL (V)
Variable
Pull-up resistance (Ω)
1K
VOH (V)
VOL (V)
0.8
Pull-up resistance (Ω)
1K
Switching capacity (A)
0.3
Switching power
(resistive)
30W
37.5VA
DC
AC
Switching voltage (V)
110
125
DC
AC
The input ports are pulled up with 1K resistors
TTL/Wiegand Output
The outputs ports are open drain type, pulled up with
1K resistors internally
Relay
30V DC
125V AC
ⒸCopyright 2007 Suprema Inc.
28
Xpass S2
FCC Rules
Caution
Warning
Information to User
Changes or modifications not expressly approved by the manufacturer
responsible for compliance could void the user’s authority to operate the
equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interface, and
(2) this device must accept any interface received, including interference that
may cause undesired operation.
This equipment has been tested and found to comply with the limit of a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, user and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation; if this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more
the following measures:
1. Reorient / Relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit difference from that to
which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for help
ⒸCopyright 2007 Suprema Inc.
29
㈜슈프리마
경기도 성남시 분당구 정자동 파크뷰 오피스타워 16층
Tel : 031-783-4510
Fax : 031-783-4503
온라인고객지원 : sales@suprema.co.kr
회사홈페이지 : www.suprema.co.kr
제품홈페이지 : www.biostation.co.kr
BioEntry Plus의 기능 및 사양은 제품의 품질 향상이나 기능 수정 등으로 인해 예고 없이 변경될 수 있습니다.
제품에 대한 자세한 사항은 ㈜슈프리마로 문의 바랍니다.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : Karl
Create Date                     : 2014:07:02 11:22:15+09:00
Modify Date                     : 2014:07:09 14:29:20+09:00
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : Karl
Title                           : Fingerprint Solutions of Suprema
Creator Tool                    : Microsoft® PowerPoint® 2013
Metadata Date                   : 2014:07:09 14:29:20+09:00
Producer                        : Microsoft® PowerPoint® 2013
Document ID                     : uuid:0aa7e100-52b0-4b0d-a98b-a0a1b5be6393
Instance ID                     : uuid:1760eeb6-50eb-4b9e-828f-06b8f1621037
Page Count                      : 31
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TKWXPS2M

Navigation menu