TAIYO YUDEN EYTMECS Complete Class 2 Bluetooth Module User Manual Manual
Taiyo Yuden Co., Ltd. Complete Class 2 Bluetooth Module Manual
Manual
6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Bluetooth® Module EYTMECS User Manual In case you adopt this module and design some appliance, please ask for the latest specifications from the local sales office. We wish the customer to request the Specification Report when the design for the mass production begins because the content of this Data Report might change without a previous notice to the customer. The Bluetooth® word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks by TAIYO YUDEN CO., LTD. is under license. TAIYO YUDEN 1/39 6-Dec.-2008 Ver.0.5 EYTMECS Document constituent list Control name General Items Absolute maximum ratings Electrical characteristics Electrical characteristics Electrical characteristics Electrical characteristics Circuit schematic Outline / Appearance Outline / Appearance Pin Layout TAIYO YUDEN Confidential & Tentative Control No. HD-AG-A080137 HD-AM-A080137 HD-AE-A080137 HD-AE-B080137 HD-AE-C080137 HD-AE-D080137 HD-MC-A080137 HD-AD-A080137 HD-AD-B080137 HD-BA-A080137 Document Page 1/3 - 3/3 1/1 1/3 - 3/3 1/2 - 2/2 1/11 - 11/11 1/11 - 11/11 1/1 1/1 1/1 1/1 Rev. record 6-Dec.-2008> Ver.0.5 Draft TAIYO YUDEN 2/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. Control name HD-AG-A080137 (1/3) General Items Scope This specification (“Specification”) applies to the hybrid IC “EYTMECS” for use Bluetooth® module (“Product”) manufacture by TAIYO YUDEN Co., Ltd. (“TAIYO YUDEN”) 1. User’s Code: EYTMECS(USB I/F Support) Digit3: Customer Code ex) S: TAIYO YUDEN Standard Digit8: Software Code ex) X: TAIYO YUDEN Standard Digit9: Hardware Code ex) X: TAIYO YUDEN Standard * User’s Code may be modified for mass production or other cases. Please see “m” for more information. Type: EYTMECS 2. Function: Radio frequency transfer Module (power class 2). Bluetooth® standard Ver 2.1+EDR conformity 3. Application: Laptop PC, PC peripheral, Handy terminal 4. Structure: Hybrid IC loaded with silicon monolithic semiconductor 5. Outline: Cable Connector Type 6. Marking: TBD 7. Features: -Bluetooth® 2.1+EDR conformity -QD ID: ****** (Controller Subsystem) -USB Interface -Hold, Sniff and Park Mode -Supported Link Type: ACL links (Piconet<7>), (e)SCO links (Piconet<3>) -AFH (Adaptive Frequency Hopping) -Faster Inquiry & Connection -EDR(Enhanced Data Rate) -SSP (Secure Simple Pairing), SSR (Sniff Subrating), EIR (Extended Inquiry Response) and EPR (Encryption Pause/Resume) 8. Packing:TBD 9. Terminal: Data input-output (10pin Cable Connector) “J.S.T.Mfg.Co.,Ltd. : SM10B-SSR-H-TB(LF)(SN)” RF input-output (Antenna) 10. Mount: TBD 11. Notes: a. Any question arising from this Specification shall be solved through mutual discussion by the parties hereof. b. This Product is not designed for radiation durable and should not be used under the circumstance of radiation. c. The operating conditions of this Product are as shown in this Specification. Please note that TAIYO YUDEN shall not be liable for a failure and/or abnormality which is caused by use under the conditions other than the operating conditions hereof. TAIYO YUDEN 3/39 6-Dec.-2008 Ver.0.5 EYTMECS Control No. HD-AG-A080137 TAIYO YUDEN Confidential & Tentative (2/3) Control name General Items d. This Product mentioned in this Specification is manufactured for use in Laptop PC, PC peripheral and Handy terminal. Before using this Product in any special equipment (such as medical equipment, space equipment, air craft, disaster prevention equipment), where higher safety and reliability are duly required, the applicability and suitability of this Product must be fully evaluated by the customer at its sole risk to ensure correct and safety operation of those special equipments. Also, evaluation of the safety function of this Product even for use in general electronics equipment shall be thoroughly made and when necessary, a protective circuit shall be added in design stage, all at the customer’s sole risk. e. TAIYO YUDEN warrants only that this Product is in conformity with this Specification for one year after purchase and shall in no event give any other warranty. f. The warranty period shall be one year. g. Communication between this Product and others might not be established nor maintained depending upon radio environment or operating conditions of this Product and other Bluetooth® products. h. This Product is designed for use in products which comply with Bluetooth® Specifications (Ver 2.1+EDR) (“Bluetooth Specifications”). TAIYO YUDEN disclaims and is not responsible for any liability concerning infringement by this Product under any intellectual property right owned by third party in case the customer uses this Product in any product which does not comply with Bluetooth Specifications (the “non-complying products”). Furthermore, TAIYO YUDEN warrants only that this Product complies with this Specification and does not grant any other warranty including warranty for application of the non-complying products. i. TAIYO YUDEN dose not render updating or upgrading service for the firmware in the Module. j. In order to take tests for getting the certification of each country’s Radio Law with a device incorporating this module, it is necessary to make the software in Host to put the module into test condition. Please contact TAIYO YUDEN for farther details. k. Please evaluate adequately our module incorporated to your products before mass production. l. This Product operates in the unlicensed ISM band at 2.4GHz. In case this Product is used around the other wireless devices which operate in same frequency band of this Product, there is a possibility that interference occurs between this Product and such other devices. If such interference occurs, please stop the operation of other devices or relocate this Product before using this Product or do not use this Product around the other wireless devices. m. User’s Code Modification Notice (Bluetooth® Modules) User’s Code may be modified based on mass production stage, Bluetooth® logo Qualification stage, or other related stages. Please contact TAIYO YUDEN to confirm whether your User’s Code needs to be modified. Please see the following examples for cases that User’s Code are modified: - for specific firmware version (our standard item firmware will be upgraded occasionally) - for specific BD address (our standard item BD address is owned by TAIYO YUDEN ) - for specific PnP (Plug and Play) IDs (our standard item PnP IDs are owned by TAIYO YUDEN or chip manufacture) EYTMECS Setting: USB Product ID : 0x0508, USB Vendor ID : 0x0930 - for other related cases (specific or different setting, form, sizes, or display etc..) In case you have applied for Bluetooth® Qualification with our standard User’s Code without previous notice to TAIYO YUDEN, we shall not be responsible for any expense that will be required to change its name/number. TAIYO YUDEN 4/39 6-Dec.-2008 Ver.0.5 EYTMECS Control No. HD-AG-A080137 TAIYO YUDEN Confidential & Tentative (3/3) Control name General Items n. Containment of hazardous substance in this Product *Pb (Lead) : Non use * This product conforms to RoHS Directive(2002/95/EC). p. In addition when this Product is used under environmental conditions such as over voltage which are not guaranteed ,it may be destroyed in short mode. To ensure the security of customer’s product, please add an extra fuse or/and a protection circuit for over voltage. q. In some cases, TAIYO YUDEN may use replacements as component parts of Products. Such replacement shall apply only to component part of Products, which TAIYO YUDEN deems it possible to replace or substitute according to (i) Scope provided in this Specification (e.g. Official Standard (Type Approvals, Bluetooth LOGO etc.)) and (ii) Quality of Products. TAIYO YUDEN also ensures traceability of such replacement on production lot basis. r. Do not alter Hardware and/or Software of this Product. Please note that TAIYO YUDEN shall not be liable for any problem if it is caused by customer's alteration of Hardware or/and Software without Taiyo Yuden's prior approvals. This module is still under development, thus specifications do not guarantee both the quality and reliability at the time of shipment. Since the specifications and mass production of the module are not confirmed either, the contents of the technical notes are subject to change without any prior notice. TAIYO YUDEN 5/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AM-A 080137 Control name Absolute maximum ratings (1/1) Absolute maximum ratings Item Supply voltage Symbol Min. Typ. Rating Max. VDD_3.3V -0.3 3.6 Vin -0.3 VDD_3.3V +0.3 Input voltage Recommendation operating range Item Symbol Supply voltage Supply voltage ripple and spike noise Operation temperature range VDD_3.3V Storage temperature range Unit Min. 3.15 Typ. 3.3 VDD_rn Rating Max. 3.45 Remark Ta=25 degrees C, GND reference I/O terminals except USB interface Unit (30) mVp-p Topr -25 25 75 Degrees C Tstg -30 25 85 Degrees C Remark Note 1 Humidity=40%RH Note 2 Humidity=40%RH Note 3 Notes: 1. To fill the standard of “Supply voltage ripple and spike noise”, the capacitor, which has the capacity of 2.2uF or more , should be put in the terminal VDD_3.3V outside as a bypass capacitor . 2. Operating temperature range is set to satisfy products electrical characteristics in the short term. In terms of product life cycle when it is used in condition of varying from TYP standard in the long term, please refer to the reliability condition. 3. Storage temperature range is the condition for transportation and storage in temporary. TAIYO YUDEN 6/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AE-A080137 Electrical characteristic (1/3) Control name Electrical characteristics DC Specifications The Specification applies for Topr.= 25 degrees C, VDD_3.3V=3.3V No. Parameter Condition 1 Normal supply voltage Symbol VDD_3.3 VIL1 Min. Typ. Max. Unit 3.15 3.3 3.45 -0.3 0.8 0.8 VDD_3.3V +0.3 2 Input Low Voltage1 /RESET, PIOX 3 Input Low Voltage2 USB_D+, USB_D- VIL2 4 Input High Voltage1 /RESET, PIOX VIH1 5 Input High Voltage2 USB_D+, USB_D- VIH2 0.7xVDD _3.3V 2.0 6 Output Low Voltage1 PIOX VOL1 0.4 7 Output Low Voltage2 USB_D+, USB_D- VOL2 0.3 8 Output High Voltage1 PIOX VOH1 9 Output High voltage2 USB_D+, USB_D- VOH2 VDD_3.3V -0.4 2.8 10 Peak current Continuous Rx Iccp1 (42) (120) 11 Average current1 Sniff mode (Slave only) Icca1 (13) 12 Average current2 Standby mode Icca2 (9) 13 Average current3 Send DM1packet (Master) Icca3 (44) 14 Average current4 15 Average current5 16 Average current6 Receive DM1packet (Slave) Hold mode (Slave only) Park mode (Slave only) Icca4 Icca5 Icca6 (45) (10) (11) Remark IOL=4mA IOH =-4mA mA Notes 3, 4 mA Notes 1, 3, 4 mA Notes 3, 4 mA Notes 3, 4 mA Notes 3, 4 mA Notes 3, 4 mA Notes 2, 3, 4 Notes: 1. Sniff mode parameter. Max interval 0050h Min interval 0010h Attempt 0005h Timeout 0005h 2. Park mode parameter. Max interval 0100h Min interval 0010h 3. The consumption current might fluctuate with the condition of radio communication, host performance and test circuit. 4. The value may fluctuate several (mA) depending on Firmware version. TAIYO YUDEN 7/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. Control name HD-AE-A080137 (2/3) Electrical characteristics AC Specifications The Specification applies for Topr.= 25 degrees C, VDD_3.3V=3.3V No. Parameter VDD_3.3V Rise Time from 0V to 3.15V Condition Symbol Min t1 10 Typ Max Unit ms Note 1 ms Note 2 ms Notes 3, 4 VDD_3.3V=3.15V to /RESET High t2 /RESET High to Module Ready t3 /RESET pulse width t4 DETACH High to USB I/F High-Z t5 DETACH Low to USB I/F Active t6 /RESET High to /RESET Low t7 3000 /RESET Low to USB_I/F High-Z t8 Module Active to /RESET Low t9 ms 10 /RESET Low to VDD_3.3V Off t10 ms ( 300 ) 3000 Remark ms 130 ms 10 ms ms 10 Note 5 ms Note 5 Notes: 1. This module has an internal EEPROM and a function to erase/sort unnecessary data if certain HCI commands are issued and consume more than a certain level of free space in the EEPROM. This operation occurs at every module initialization (power-on). If supply voltage becomes non-defined states during initialization or writing in EEPROM, data in EEPROM might be destroyed. If the data in EEPROM is destroyed, module will not work correctly. Therefore please be sure to stabilize power source before /RESET release. In addition please design module peripheral circuits to avoid temporary blackout of power source during operation. Please refer HD-AE-C 080137 for HCI command which rewrites flash memory data. 2. Input /RESET signal of 10ms and more in condition of VDD_3.3V at over 3.15V. 3. When the module is ready to accept the command, its module outputs the “0F 04 00 01 00 00” (Hex) to the USB Data Line. After that, please access to the module. 4. The Typ. is a reference value. The value may change depending on the firmware version, conditions of use. 5. You don’t need to wait t6 if you confirm that this module has output “0F 04 00 01 00 00” (Hex). TAIYO YUDEN 8/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AE-A080137 Control name Electrical characteristics (3/3) VDD_3.3V t2 t7 t1 /RESET t4 USB_DETACH t3 t9 t8 t5 Active USB_I/F Active t6 Active Timing Diagram for Power Up Sequence VDD_3.3V t10 /RESET USB_DETACH USB_I/F Active Timing Diagram for Power Down Sequence TAIYO YUDEN 9/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AE-B080137 (1/2) Control name Electrical characteristics RF Specifications at Basic Rate The Specification applies for Ta=25 degrees C, VDD_3.3V=3.3V No. Parameter Condition Symbol Min Typ Max Unit FREQ PO 2400 -6 2483.5 MHz +4 dBm dF1: F0(11110000) M1 140 dF2: AA(10101010) M4 115 dF2/dF1 MC 0.8 2MHz(|M-N|=2) ISE1 -20 dBm 3MHz or greater (|M-N|>=3) ISE2 -40 dBm Remark 10 11 12 13 14 15 Frequency band Tx power Modulation characteristics 1 Modulation characteristics 2 Modulation characteristics 3 In-band spurious emission 2 In-band spurious emission 3 Initial Carrier Frequency Frequency Drift 1 Frequency Drift 2 Drift rate C/I co-channel C/I 1MHz C/I 2MHz C/I >= 3MHz 16 C/I Image CI4 -9 dB 17 C/I Image +/- 1MHz Out-of-Band Blocking 1 Out-of-Band Blocking 2 Out-of-Band Blocking 3 CI5 -20 dB OBB1 -10 dBm OBB2 -27 dBm OBB3 -27 dBm OBB4 -10 dBm BER<=0.1 dBm BER<=0.1 18 19 20 21 Out-of-Band Blocking 4 23 Maximum Input Level 20dB Bandwidth 24 Sensitivity-single 25 Sensitivity-multi 22 DH1 DH3,DH5 DH1,DH3,DH5 30MHz to 2000MHz f=2460MHz 2000 to 2399MHz f=2460MHz 2484 to 3000MHz f=2460MHz 3000MHz to 12.75GHz f=2460MHz 175 kHz kHz ICF -75 +75 kHz FD1 FD2 DR CIC CI1 CI2 CI3 -25 -40 +25 +40 400 11 -30 -40 kHz kHz Hz/us dB dB dB dB MAXP -20 B20 MHz DH1 SEN1 -70 dBm DH3,DH5 SEN2 -70 dBm TAIYO YUDEN -60dBm -60dBm -60dBm -67dBm -3MHz offset -67dBm -67dBm BER<=0.1 BER<=0.1 BER<=0.1 BER<=0.1 BER<=0.1 10/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AE-B080137 (2/2) Control name Electrical characteristics RF Specifications at EDR The Specification applies for Ta=25 degrees C, VDD_3.3V =3.3V No. Parameter Condition 15 16 17 18 RMS DEVM 1 RMS DEVM 2 Peak DEVM 1 Peak DEVM 2 99% DEVM 1 99% DEVM 2 EDR In-band spurious emission 1 EDR In-band spurious emission 2 EDR In-band spurious emission 3 EDR Initial Carrier Frequency EDR Drift Relative transmit power Actual Sensitivity Level BER Floor Performance C/I co-channel C/I 1MHz C/I 2MHz C/I >= 3MHz 2-DH5(3-DH5) 16000000bit 2-DH5(3-DH5) 160000000bit 2-DH5 2-DH5 2-DH5 2-DH5 19 C/I Image 20 21 22 23 24 10 11 12 Symbol Min Typ Max Unit Pai/4DQPSK 8DPSK Pai/4DQPSK 8DPSK Pai/4DQPSK 8DPSK RDE1 RDE2 PDE1 PDE2 D991 D992 |M-N|=1 EISE1 |M-N|=2 EISE2 -20 dBm |M-N|=3 EISE3 -40 dBm -75 +75 kHz -10 PGFSK -4 +10 PGFSK +1 kHz EICF ED PDPSK RTP Remark 0.20 0.13 0.35 0.25 0.30 0.20 26 dB dB ESEN -70 dBm BER= 10-4 FSEN -60 dBm BER= 10-5 2CIC 2CI1 2CI2 2CI3 13 -30 -40 dB dB dB dB 2-DH5 2CI4 -7 dB C/I Image +/- 1MHz C/I co-channel C/I 1MHz C/I 2MHz C/I >= 3MHz 2-DH5 3-DH5 3-DH5 3-DH5 3-DH5 2CI5 3CIC 3CI1 3CI2 3CI3 -20 21 -25 -33 dB dB dB dB dB 25 C/I Image 3-DH5 3CI4 dB 26 C/I Image +/- 1MHz 3-DH5 -13 dB 27 Maximum Input Level 2-DH5(3-DH5) 3CI5 EMAX 13 14 -20 -60dBm -60dBm -60dBm -67dBm -67dBm -3MHz offset -67dBm -60dBm -60dBm -60dBm -67dBm -67dBm -3MHz offset -67dBm dBm Note: Bluetooth® standard Ver 2.1+EDR conformity TAIYO YUDEN 11/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. Control name HD-AE-C080137 (1/11) Electrical characteristics Supported HCI Commands / HCI Events The Bluetooth® functions of this module is as written in the attached PICS. Depending on firmware version Upgrade, the Bluetooth® functions are subject to change without notice. Firmware Version 23E (Build5276) HCI COMMAND LIST Command Description Device Setup HCI _Reset OpCode Group Command Parameters 0x0C03 States Yes Status HC ACL Data Packet Length HC Synchronous Data Packet Length HC Total Num ACL Data Packets HC Total Num Synchronous Data Packets Yes Controller Flow Control HCI _Read _Buffer _Size 0x1005 Controller Information HCI _Read _Local _Version _ Information 0x1001 0x1002 0x1003 HCI _Read _Local _Extended _Features 0x1004 HCI _Read _BD _ADDR 0x1009 HCI _Read _Local _Name HCI _Write _Local _Name 0x0C14 0x0C13 14 13 HCI _Read _Class _of _Device 0x0C23 23 HCI _Write _Class _of _Device HCI _Read _Number _Of _Support _IAC 0x0C24 24 0x0C38 38 HCI _Read _Current _IAC _LAP 0x0C39 39 HCI _Write _Current _IAC _LAP 0x0C3A 3A HCI _Read _Scan _Enable 0x0C19 19 HCI _Write _Scan _Enable 0x0C1A 1A HCI _Read _Local _Supported _Commands HCI _Read _Local _Supported _Features Controller Configuration Page number Local Name Class of Device Num Current IAC IAC LAP [I] Scan Enable TAIYO YUDEN Returns Status HCI Version HCI Revision LMP Version Manufacturer Name LMP Subversion Status Supported Commands Status LMP Features Status Page number Maximum Page Number Extended LMP Features Status BD ADDR Status Yes Yes Yes Yes Yes States States States Class of Device States States Num Support IAC States Num Current IAC IAC LAP [I] Yes States Yes States Scan Enable States Notes Yes Yes Yes Yes Yes Yes Yes 12/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AE-C080137 Device Discovery Control name Electrical characteristics (2/11) HCI _Inquiry 0x0401 HCI _ Inquiry_ Cancel 0x0402 HCI_ Periodic_ Inquiry _Mode 0x0403 HCI _Exit _Periodic _Inquiry _Mode 0x0404 HCI _Read _Inquiry _Scan _Activity 0x0C1D 1D HCI _Write _Inquiry _Scan _Activity 0x0C1E 1E HCI _Read _Inquiry _Scan _Type 0x0C42 42 HCI _Write _Inquiry _Scan _Type 0x0C43 43 HCI _Read _Inquiry _Mode 0x0C44 44 HCI _Write _Inquiry _Mode HCI_Read_Inquiry_Response _Transmit_Power_Level HCI_Write_Inquiry_Transmit_Powe r _Level 0x0C45 45 0x0C58 58 0x0C59 59 HCI_Read_Extended_Inquiry_ Response 0x0C51 51 HCI_Write_Extended_Inquiry_ Response 0x0C52 52 Connection Setup LAP Inquiry Length Num Responses Max Period Length Min Period Length LAP Inquiry Length Num Responses Inquiry Scan Interval Inquiry Scan Window Scan Type Inquiry Mode TX_Power FEC_Required Extended_Inquiry_ Response Yes Status Yes Status Yes Status States Inquiry Scan Interval Inquiry Scan Window Yes States Yes Status Scan Type Status Status Inquiry Mode Status Status TX_Power 0x0405 HCI _Accept _Connection _Request 0x0409 HCI _Reject _Connection _Request 0x040A HCI _Create _Connection _Cancel 0x0408 BD ADDR HCI _Disconnect 0x0406 Connection Handle Reason Packet Type HCI _Read _Page _Timeout 0x0C17 17 HCI _Write _Page _Timeout 0x0C18 18 HCI _Read _Page _Scan _Activity 0x0C1B 1B HCI _Write _Page _Scan _Activity 0x0C1C 1C Page Timeout Page Scan Interval Page Scan Window TAIYO YUDEN Yes Yes Yes Yes Yes Status Yes Status FEC_Required Extended_Inquiry_ Response Yes Status Yes BD ADDR Packet Type Page Scan Repetition Mode Reserved Clock Offset Allow Role Switch BD ADDR Role BD ADDR Reason HCI _Create_ Connection Yes Yes Yes Yes Status BD ADDR Yes Yes States Page Timeout States States Page Scan Interval Page Scan Window States Yes Yes Yes Yes 13/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AE-C080137 Control name Electrical characteristics (3/11) HCI _Read _Page _Scan _Type 0x0C46 46 HCI _Write _Page _Scan_Type HCI_Read_Connection_ Accept_Timeout HCI_Write_Connection_ Accept_Timeout 0x0C47 47 0x0C15 15 0x0C16 16 Conn_Accept_Timeout Remote Information HCI _Remote _Name_ Request HCI _Remote _Name _Request _Cancel HCI _Read _Remote _Supported _Features HCI _Read _Remote _Extended _Features HCI _Read _Remote _Version _Information Yes Status Yes Yes Yes 0x0419 19 BD ADDR Page Scan Repetition Mode Page Scan Mode Clock Offset 0x041A 1A BD_ADDR 0x041B 1B Connection Handle Yes Yes Yes 0x041C 1C Connection Handle Page_Number 0x041D 1D Connection Handle Synchronous Connections HCI _Setup _Synchronous _Connection 0x0428 28 HCI _Accept _Synchronous _Connection _Request 0x0429 29 HCI _Reject _Synchronous _Connection _Request 0x042A 2A HCI _Read _Voice _Setting 0x0C25 25 HCI _Write _Voice _Setting HCI_Write_Default_Erroneous_Dat a_Reporting 0x0C26 26 0x0C5B 5B 0x0C5A 5A HCI_Read_Default_Erroneous_Dat a_Reporting Page_Scan_Type States Page_Scan_Type States Status Conn_Accept_Timeout Yes Status BD_ADDR Connection Handle Transmit Bandwidth Receive Bandwidth Max Latency Voice Setting Retransmission Effort Packet Type BD ADDR Transmit Bandwidth Receive Bandwidth Max Latency Content Format Retransmission Effort Packet Type Yes Yes BD ADDR Voice setting Erroneous_Data_Reporti ng TAIYO YUDEN Yes Yes States Voice Setting States Yes Status No Status Erroneous_Data_ Reporting No Yes 14/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AE-C080137 Connection State HCI _Hold _Mode (4/11) 0x0801 Control name Electrical characteristics Connection Handle Yes Hold Mode Max Interval Hold Mode Min Internal Connection Handle Sniff Max Interval Sniff Min Interval Sniff Attempt Sniff Timeout Connection Handle Connection Handle Beacon Max Interval Beacon Min Interval Connection Handle Connection Handle HCI _Sniff _Mode 0x0803 HCI _Exit _Sniff _Mode 0x0804 HCI _Park _State 0x0805 HCI _Exit _Park _State 0x0806 HCI _Read _Link _Policy _Settings 0x080C HCI _Write _Link _Policy _Settings 0x080D HCI _Read _Default _Link _Policy _Settings 0x080E HCI _Write _Default _Link _Policy_Settings 0x080F HCI _Read _Hold _Mode _Activity 0x0C2B 2B HCI _Write _Hold _Mode _Activity 0x0C2C 2C HCI _Role _Discovery 0x0809 Connection Handle HCI _Switch _Role 0x080B BD ADDR Role Connection Handle Link Policy settings Default Link Policy Settings Quality Service 0x0810 10 0x0807 0x0C08 HCI _QoS _Setup HCI _Flush Yes Yes States Connection Handle Link Policy Settings States Connection Handle Status Default Link Policy Settings Status States Hold Mode Activity Hold Mode Activity Piconet Structure HCI _Flow _Specification Yes Connection Handle Flags Flow direction Service Type Token Rate Token Bucket Size Peak Bandwidth Access Latency Connection Handle Flags Service Type Token Rate Peak Bandwidth Latency Delay Variation Connection Handle TAIYO YUDEN Yes Yes Yes Yes Yes Yes States Yes Status Connection Handle Current Role Yes Yes Yes Yes States Connection Handle Yes 15/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AE-C080137 (5/11) Control name Electrical characteristics HCI _Read _Automatic _Flush _Timeout 0x0C27 27 Connection Handle HCI _Write _Automatic _Flush_ Timeout 0x0C28 28 Connection Handle Flash Timeout HCI _Read _Failed _Contact _Counter 0x1401 Connection Handle 0x1402 Connection Handle 0x0C29 29 0x0C2A 2A 0x0C5F 5F HCI _Reset _Failed _Contact _Counter HCI _Read _Num _Broadcast_ Retransmission HCI _Write _Num _Broadcast_ Retransmission HCI_Enhanced_Flush HCI_Sniff_Subrating 0x0811 11 Num Broadcast Retransmission Connection_Handle Packet_Type Connection_Handle Maximum_Latency Minimum_Remote_ Timeout Minimum_Local_Timeo ut Physical Links HCI _Read _Link _Supervision _Timeout 0x0C36 36 Connection Handle HCI _Write _Link _Supervision _Timeout 0x0C37 37 Connection Handle Link Supervision Timeout HCI Read _AFH _Channel _Assessment _Mode 0x0C48 48 0x0C49 49 0x0C3F 3F 0x040F HCI Write _AFH _Channel _Assessment _Mode HCI _Set _AFH _Host _Channel _Classification HCI _Change _Connection _Packet_Type Host Flow Control HCI _Host _Buffer _Size 0x0C33 33 HCI _Set _Event _Mask 0x0C01 HCI _Set _Event _Filter 0x0C05 HCI _Set _Controller _To _Host _Flow _Control 0x0C31 31 AFH Channel Assessment Mode AH Host Channel Classification Connection Handle Packet Type Host ACL Data Packet Length Host SCO Data Packet Length Host Total Num ACL Data Packets Host Total Num SCO Data Packets Event Mask Filter Type Filter Condition Type Condition Flow Control Enable TAIYO YUDEN States Connection Handle Flush Timeout States Connection Handle Status Connection Handle Failed Contact Counter Status Connection Handle Yes Yes Yes Yes States Yes States Yes Yes Status Connection_Handle Yes States Connection Handle Link Supervision Timeout States Connection Handle Yes Yes Status AFH Channel Assessment Mode Yes Status Yes Status Yes Yes States Yes States Yes States Yes States Yes 16/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AE-C080137 (6/11) HCI _Host _Number _Of _Completed _Packets 0x0C35 35 HCI _Read _Synchronous _Flow _Control _Enable 0x0C2E 2E HCI _Write _ Synchronous _Flow _Control _Enable 0x0C2F 2F Control name Electrical characteristics Number of Handles Connection handle [I] Host Num of Completed Packets [I] Synchronous Flow Control Enable Link Information HCI _Read _LMP _Handle 0x0420 20 Connection Handle HCI _Read _Transmit _Power _Level 0x0C2D 2D HCI _Read _Link _Quality 0x1403 Connection Handle HCI _Read _RSSI 0x1405 Connection Handle HCI _Read _Clock _Offset 0x041F 1F Connection Handle HCI _Read _Clock 0x1407 Connection Handle Type Connection Handle Which Clock HCI _Read _AFH _Channel _Map 0x1406 Connection Handle 0x0C1F 1F 0x0C20 20 HCI _Read _Encryption _Mode 0x0C21 21 HCI _Write _Encryption _Mode 0x0C22 22 HCI _Link _Key _Request _Reply 0x040B HCI _Link _Key _Request _Negative _Reply 0x040C BD ADDR HCI _PIN _Code _Request _Reply 0x040D BD ADDR PIN Code Length PIN Code Yes States Synchronous Flow Control Enable Yes States Yes Status Connection Handle LMP_Handle Reseved States Connection Handle Power Level Status Connection Handle Link Quality Status Connection Handle RSSI Status Connection Handle Clock Accuracy Status Connection Handle AFH Mode AFH Channel Map Yes Yes Yes Yes Yes Yes Yes Authentication and Encryption HCI _Read _Authentication _Enable HCI _Write _Authentication _Enable Authentication Enable Encryption Mode BD ADDR Link Key States Authentication Enable Yes States Yes States Encryption Mode States Status BD ADDR Status BD ADDR Status BD ADDR Status BD ADDR Yes Yes Yes Yes Yes HCI _PIN _Code _Request _Negative _Reply HCI _Authentication _Requested 0x040E BD ADDR 0x0411 11 Yes HCI _Set _Connection _Encryption 0x0413 13 Connection Handle Connection Handle Encryption Enable 0x0415 15 Connection Handle Yes 0x0417 17 Key Flag Yes HCI _Change _Connection _Link _Key HCI _Master _Link _Key TAIYO YUDEN Yes Yes 17/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AE-C080137 Control name Electrical characteristics (7/11) States PIN Type States States Max Num Keys Num Keys Read States HCI _Read _PIN _Type 0x0C09 HCI _Write _PIN _Type 0x0C0A HCI _Read _Stored _Link _Key 0x0C0D HCI _Write _Stored _Link _Key 0x0C11 11 HCI _Delete _Stored _Link _Key 0x0C12 12 HCI _Create _New _Unit _Key HCI_User_Confirmation_Request_ Reply HCI_User_Confirmation_Request_ Negative_Reply 0x0C0B 0x042C 2C BD ADDR 0x042D 2D BD ADDR HCI_User_Passkey_Request_Reply 0x042E 2E BD ADDR Numeric_Value HCI_User_Passkey_Request_ Negative_Reply 0x042F 2F BD ADDR HCI_Remote_OOB_Data_Request _Reply 0x0430 30 BD ADDR C (Hash C) R (Randomizer R) HCI_Remote_OOB_Data_Request _Negative_Reply 0x0433 33 BD ADDR Status HCI_Read_Local_OOB_Data 0x0C57 57 HCI_Write_Simple_Pairing_mode 0x0C56 56 Simple_Pairing_Mode HCI_Read_Simple_Pairing_mode 0x0C55 55 HCI_Refresh_Encryption_Key 0x0C53 53 Status C (Hash C) R (Randomizer R) Status Status Simple_Pairing_Mode Status HCI _Read _Loopback _Mode 0x1801 HCI _Write _Loopback _Mode 0x1802 0x1803 0x1804 PIN Type BD ADDR Read All Flag Num Keys To Write BD ADDR [I] Link Key [I] BD ADDR Delete All Flag Connection_Handle Num Keys Written States Num Keys Deleted Local Name States Status BD ADDR Status BD ADDR Status BD ADDR Status BD ADDR Status BD ADDR Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Testing HCI _Enable _Device _Under _Test_Mode HCI_Write_Simple_Pairing_ Debug_mode Loopback Mode Simple_Pairing_Debug_ Mode TAIYO YUDEN States Loopback Mode Yes Status Yes Status Yes Status Yes 18/39 6-Dec.-2008 Ver.0.5 EYTMECS Control No. HD-AE-C080137 TAIYO YUDEN Confidential & Tentative Control name Electrical characteristics (8/11) HCI EVENT LIST Event Description OpCode Parameters Status Inquiry _Complete 0x01 Yes Inquiry _Result 0x02 Connection _Complete 0x03 Connection _Request 0x04 Disconnection _Complete 0x05 Authentication _Complete 0x06 Remote _Name _Request _Complete 0x07 Encryption _Change 0x08 Change _Connection _Link _Key _Complete 0x09 Master _Link _Key _Complete 0x0A Read _Remote _Supported _Features _Complete 0x0B Read _Remote _Version _Information _Complete 0x0C QoS _Setup _Complete 0x0D Command _Complete 0x0E Status Num Responses BD ADDR [I] Page Scan Repetition Mode [I] Page Scan Period Mode [I] Page Scan Mode [I] Class of Device [I] Clock Offset [I] Status Connection Handle BD ADDR Link Type Encryption Mode BD ADDR Class of Device Link Type Status Connection Handle Reason Status Connection Handle Status BD ADDR Remote Name Status Connection Handle Encryption Enable Status Connection Handle Status Connection Handle Key Flag Status Connection Handle LMP Features Status Connection Handle LMP Version Manufacture Name LMP Subversion Status Connection Handle Flags Service Type Token Rate Peak Bandwidth Latency Delay Variation Num HCI Command Packets Command Opcode Return Parameters TAIYO YUDEN Notes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 19/39 6-Dec.-2008 Ver.0.5 EYTMECS Control No. HD-AE-C080137 TAIYO YUDEN Confidential & Tentative Control name Electrical characteristics (9/11) Command _Status 0x0F Hardware _Error Flush _Occurred 0x10 0x11 Role _Change 0x12 Number _Of _Completed _Packets 0x13 Mode _Change 0x14 Return _Link _Keys 0x15 PIN _Code _Request Link _Key _Request 0x16 0x17 Link _Key _Notification 0x18 Loopback _Command Data _Buffer _Overflow 0x19 0x1A Max _Slots _Change 0x1B Read _Clock _Offset _Complete 0x1C Connection _Packet _Type _Change 0x1D QoS _Violation 0x1E Page _Scan _Repetition _Mode _Change 0x20 Flow _Specification _Complete 0x21 Inquiry _Result _with _RSSI 0x22 Read _Remote _Extended _Features _Complete 0x23 Status Num HCI Command Packets Command Opcode Hardware Code Connection Handle Status BD ADDR New Role Number of Handles Connection Handle [I] HC Num HCI Data Packets [I] Status Connection Handle Current Mode Interval Num Keys BD ADDR [I] Link Key [I] BD ADDR BD ADDR BD ADDR Link Key HCI Command Packet Link Type Connection Handle LMP Max Slots Status Connection Handle Clock Offset Status Connection Handle Packet Type Connection Handle BD ADDR Page Scan Repetition Mode Status Connection Handle Flags Flow direction Service Type Token Rate Token Bucket Size Peak Bandwidth Access Latency Num Responses BD ADDR [I] Page Scan Repetition Mode [I] Page Scan Period Mode [I] Page Scan Mode [I] Class of Device [I] Clock Offset [I] RSSI [I] Status Connection Handle Page Number Maximum page number Extended LMP Features TAIYO YUDEN Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes No Yes Yes Yes Yes 20/39 6-Dec.-2008 Ver.0.5 EYTMECS Control No. HD-AE-C080137 TAIYO YUDEN Confidential & Tentative Control name Electrical characteristics (10/11) Synchronous _Connection _Complete 0x2C Synchronous _Connection _Changed 0x2D Sniff Subrating 0x2E Extended Inquiry Result 0x2F Encryption Key Refresh Complete 0x30 IO Capability Request 0x31 IO Capability Response 0x32 User Confirmation Request 0x33 User Passkey Request Remote OOB Data Request 0x34 0x35 Simple Pairing Complete 0x36 Link Supervision Timeout Changed 0x38 Enhanced Flush Complete 0x39 User Passkey Notification 0x3B Keypress Notification 0x3C Remote Host Supported Features Notification 0x3D Status Connection Handle BD ADDR Link Type Transmission Interval Retransmission Window Rx Packet Length Tx Packet Length Air Mode Status Connection Handle Transmission Interval Retransmission Window Rx Packet Length Tx Packet Length Status Connection_Handle Maximum_Transmit_Latency Maximum_Receive_Latency Minimum_Remote_Timeout Minimum_Local_Timeout Num_Responses BD_ADDR Page_Scan_Repetition_Mode Reserved Class_of_Device Clock_Offset RSSI Extended_Inquiry_Response Status Connection_Handle BD_ADDR BD_ADDR IO_Capability OOB_Data_Present Authentication_ Requirements BD_ADDR Numeric_Value BD_ADDR BD_ADDR Status BD_ADDR Connection_Handle Link_Supervision_Timeout Connection_Handle BD_ADDR Passkey BD_ADDR Notification_Type BD_ADDR Host_Supported_Features TAIYO YUDEN Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 21/39 6-Dec.-2008 Ver.0.5 EYTMECS Control No. HD-AE-C080137 TAIYO YUDEN Confidential & Tentative (11/11) Control name Electrical characteristics Module Stack USB I/F HOST USB HCI Host Transport HCI Implementation Link Manager Link Controller Base Band Radio Note: The protocol stack in the module is compliant with the Specification of the Bluetooth® System V2.1+EDR Bluetooth® Module TAIYO YUDEN 22/39 6-Dec.-2008 Ver.0.5 EYTMECS Control No. HD-AE-D080137 TAIYO YUDEN Confidential & Tentative (1/11) Control name Electrical characteristics PICS for Firmware Version 23E (Build5276) The Bluetooth® functions of this module are as below. Depending on firmware version upgrade, the Bluetooth® functions are subject to change without notice. Summary ICS: Table 21: Controller Core Specification Item Capability Core Spec Version 2.1 Core Spec Version 2.1 + EDR (Ver. 2.1 + EDR) M.1: Mandatory to choose at least one version from Table 21. Status M.1 M.1 Support No Yes Table 22: EDR Features Capability Status Support Item EDR for asynchronous transports (single slot) C.1 Yes EDR for asynchronous transports (multi slot) C.1 Yes EDR for asynchronous transports C.1 Yes C.1: For implementations supporting Ver. 2.1+EDR, the Supplier shall indicate support for one or more Enhanced Data Rate features (per specification Volume 0, Part B) in Table 22. RF Capabilities (based on PICS proforma for Radio): Table 1: RF Capabilities Item Capability Power Class =1 Power Class =2 Power Class=3 Power Control 1-slot packets supported 3-slot packets supported 5-slot packets supported 79 Channels Support for GFSK modulation 10 Support for π/4-DQPSK modulation 11 Support for 8DPSK modulation M.1: Must choose One and only One Power Class Status M.1 M.1 M.1 C.1 C.2 C.3 Support No Yes No Yes Yes Yes Yes Yes Yes Yes Yes C.1: Mandatory to support IF Power Class 1 is supported, ELSE Optional C.2: Mandatory IF SUM (21/4) OR SUM (21/6) is claimed, Optional IF SUM (21/3) OR SUM (21/5) is claimed, Excluded otherwise. C.3: Mandatory IF SUM (21/4) OR SUM (21/6) is claimed, Optional IF RF(1/8) AND ( SUM (21/3) OR SUM (21/5) ) are claimed TAIYO YUDEN 23/39 6-Dec.-2008 Ver.0.5 EYTMECS Control No. HD-AE-D080137 TAIYO YUDEN Confidential & Tentative (2/11) Control name Electrical characteristics Baseband Capabilities (based on PICS proforma for Baseband) Table 1: Physical Channel Item Capability Support frequency band and 79 RF channels Adaptive Frequency Hopping Kernel Item Capability Basic Data Rate, 1 Mbps payload data rate Enhanced Data Rate, 2 Mbps payload data rate Enhanced Data Rate, 3 Mbps payload data rate Table 1a: Modulation schemes Status Support Yes Yes Status C.1 C.2 Support Yes Yes Yes C.1 Mandatory IF SUMMARY(21/6) is claimed, Optional IF SUMMARY(21/5) is claimed C.2 Mandatory IF SUMMARY(21/6) is claimed, Optional IF BB(1a/2) AND SUMMARY(21/5) are claimed Table 2: Link Types Item Capability Status Support Support of ACL link Yes Support of SCO link Yes Support of eSCO link Yes Support of Enhanced Data Rate ACL links C.1 Yes Support of Enhanced Data Rate eSCO links C.2 Yes C.1 Mandatory IF SUMMARY(22/1) OR SUMMARY(22/2) is claimed, Optional IF SUMMARY(21/5) OR SUMMARY(21/6) is claimed C.2 Mandatory IF SUMMARY(22/3) is claimed, Optional IF SUMMARY(21/5) OR SUMMARY(21/6) is claimed Table 3: SCO Link support Prerequisite for Items (3/5-8):(2/3) (Support of eSCO link) Prerequisite for Items (3/1-4):(2/2) (Support of SCO link) Item Capability SCO links to same Slave SCO links to different Slaves SCO links from same Master SCO links from different Masters eSCO links to same Slave eSCO links to different Slaves eSCO links from same Master eSCO links from different Masters C.1: Mandatory to support at least One link (3/1 3/3) Status C.1 C.1 C.2 C.2 Support Yes Yes Yes No Yes Yes Yes No Status Support Yes Yes Yes Yes Yes C.2: Mandatory to support at least One link (3/5 or 3/7) Item Table 4: Common packet types Support of ID packet type Support of NULL packet type Support of POLL packet type Support of FHS packet type Support of DM1 packet type Capability TAIYO YUDEN 24/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AE-D080137 Item (3/11) Control name Electrical characteristics Table 5: ACL packet types Support of DH1 packet type Support of DM3 packet type Support of DH3 packet type Support of DM5 packet type Support of DH5 packet type Support of AUX1 packet type Capability Status Support Yes Yes Yes Yes Yes Yes Table 5a: Enhanced Data Rate ACL Packet Types Prerequisite: 2/4 (Support of Enhanced Data Rate ACL links) Item Capability Status Support 2-DH1 packet type C.1 Support 2-DH3 packet type C.2 Support 2-DH5 packet type C.2 Support 3-DH1 packet type C.3 Support 3-DH3 packet type C.4 Support 3-DH5 packet type C.5 C.1 Mandatory IF SUMMARY(22/1) OR SUMMARY(22/2) is claimed, Optional IF BB(1a/2) is claimed Support Yes Yes Yes Yes Yes Yes C.2 Mandatory IF SUMMARY(22/2) is claimed, Optional IF BB(1a/2) is claimed C.3 Mandatory IF SUMMARY(22/1) OR SUMMARY(22/2) is claimed, Optional IF BB(1a/3) is claimed C.4 Mandatory IF SUMMARY(22/2) is claimed, Optional IF BB(5a/2) AND BB(5a/4) are claimed C.5 Mandatory IF SUMMARY(22/2) is claimed, Optional IF BB(5a/3) AND BB(5a/4) are claimed Table 6: SCO and eSCO packet types Prerequisite for Items (6/1-4):(2/2) (Support of SCO link) Prerequisite for Items (6/5-7):(2/3) (Support of eSCO link) Item Capability Support of HV1 packet type Support of HV2 packet type Support of HV3 packet type Support of DV packet type Support of EV3 packet type Support of EV4 packet type Support of EV5 packet type C.1 Mandatory IF only (2/2) SCO link is supported Status C.1 C.1 C.2 Support Yes Yes Yes Yes Yes Yes Yes C.2 Mandatory IF only (2/3) eSCO link is supported Table 6a: Enhanced Data Rate eSCO packet types Prerequisite: 2/5 (Support Enhanced Data Rate eSCO links) Capability Item Support 2 –EV3 packet type Support 2 –EV5 packet type Support 3 –EV3 packet type Support 3 –EV5 packet type C.1 Mandatory IF SUMMARY(22/3) is claimed, Optional IF BB(1a/2) is claimed Status C.1 C.2 C.3 C.4 Support Yes Yes Yes Yes C.2 Optional IF BB(1a/2) is claimed C.3 Mandatory IF SUMMARY(22/3) is claimed Optional IF BB(1a/3) is claimed C.4 Optional IF BB(1a/3) is claimed TAIYO YUDEN 25/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AE-D080137 Item (4/11) Control name Electrical characteristics Table 7: Page procedures Support Yes Yes No No Yes Status Support Yes Status C.1 C.1 C.1 Support Yes Yes Yes Item Capability Status Supports Npage >= 1 Supports Npage >= 128 Supports Npage >= 256 Note: The master should use Npage >= 256 unless it knows what SR mode the slave uses. Support Yes Yes Yes Item Capability Support paging Support page scan (Intentionally left blank) (Intentionally left blank) Supports Interlaced Scan during page scan Table 8: Paging schemes Capability Supports mandatory scan mode Table 9: Paging modes Capability Item Supports paging mode R0 Supports paging mode R1 Supports paging mode R2 C.1: At least one of the paging scan modes must be supported. Status Table 9b: Paging train repetition Item Item Item Table 10: Inquiry procedures Support inquiry Inquiry scan with first FHS Capability (Intentionally left blank) (Intentionally left blank) Supports the dedicated inquiry access code Supports Interlaced Scan during inquiry scan Extended Inquiry Response Table 11: Piconet capabilities Capability Broadcast messages Point-to-multipoint connections Table 12: Scatternet capabilities Capability Act as Master in one piconet and as Slave in another piconet Act as Slave in more than one piconet Status Support Yes Yes No No Yes Yes Yes Status Support Yes Yes Status Support Yes Yes Status Support Yes Yes Yes Yes Table 13: Synchronous Coding Schemes Prerequisite: 2/2 (SCO link support) Item Capability A-law u-law CVSD Transparent Synchronous Data TAIYO YUDEN 26/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AE-D080137 Item (5/11) Control name Electrical characteristics Table 14: Erroneous Data Reporting Capability Erroneous Data Reporting for SCO Erroneous Data Reporting for eSCO Status C.1 C.2 Support Yes Yes C.1: Optional IF ((SUM ICS: 21/5 OR SUM ICS: 21/6) AND HCI: 9/6) is supported, ELSE excluded. C.2: Optional IF ((SUM ICS: 21/5 OR SUM ICS: 21/6) AND HCI: 9/7) is supported, ELSE excluded. Item Item Table 15: This table is intentionally left blank: DO NOT USE Capability (Intentionally left blank) Table 16: Non-flushable Packet Boundary Flag Capability Support Non-flushable Packet Boundary Flag Status Support No Status C.1 Support Yes C.1 MANDATORY IF ((SUM ICS: 21/5 OR SUM ICS 21/6) AND HCI: 12/10) is supported, ELSE OPTIONAL IF (SUM ICS: 21/5 OR SUM ICS: 21/6) is supported, ELSE excluded. Item Table 17: Connection States Sniff Subrating Mode Capability Status C.1 Support Yes C.1 MANDATORY IF ((SUM ICS: 21/5 OR SUM ICS 21/6) AND LMP: 2/8) is supported, ELSE OPTIONAL IF (SUM ICS: 21/5 OR SUM ICS: 21/6) is supported, ELSE excluded. TAIYO YUDEN 27/39 6-Dec.-2008 Ver.0.5 EYTMECS Control No. HD-AE-D080137 TAIYO YUDEN Confidential & Tentative Control name Electrical characteristics (6/11) Link Manager Capabilities (based on PICS proforma for Link Manager) Item Table 1: Response Messages Accept message Reject message Capability Status Support Yes Yes Status C.5 C.1 C.2 C.3 C.4 Support Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Table 2: Supported Features Item Capability 3-slot packets 5-slot packets Encryption Slot offset Timing accuracy Role switch (Master/Slave) Hold mode Sniff mode Park mode 10 Power Control 11 Channel quality driven data rate 12 SCO link 13 RSSI 14 Broadcast encryption 15 eSCO link 16 Adaptive frequency hopping 17 Enhanced Data Rate ACL 18 Enhanced Data Rate eSCO 19 Simple Pairing C.1: Mandatory IF (RF:1/1) supported, ELSE Optional C.2 Mandatory IF (SUMMARY:22/1) OR (SUMMARY:22/2) is claimed, Optional IF (SUMMARY:21/5) OR (SUMMARY:21/6) is claimed C.3 Mandatory IF (SUMMARY:22/3) is claimed, Optional IF (SUMMARY:21/5) OR (SUMMARY:21/6) is claimed C.4 Mandatory IF (SUMMARY 2-1/5 OR SUMMARY 2-1/6) is claimed, ELSE Excluded. C.5 Optional IF (SUMMARY 2-1/1 OR SUMMARY 2-1/2 OR SUMMARY 2-1/3 OR SUMMARY 2-1/4) ELSE Mandatory. Item Table 3: Authentication Capability Initiate authentication before connection completed Initiate authentication after connection completed Respond to authentication request Table 4: Pairing Item Capability Initiate pairing before connection completed Initiate pairing after connection completed Respond to pairing request Use fixed PIN and request responder to initiator switch Use variable PIN Accept initiator to responder switch C.1: Mandatory to support at least One, (LMP:4/4) OR (LMP:4/5) OR both Status Support Yes Yes Yes Status C.1 C.1 C.2 Support Yes Yes Yes Yes Yes Yes C.2: Mandatory IF (LMP: 4/5) AND (LMP:4/1), OR (LMP: 4/5) AND (LMP:4/2) ) is supported. TAIYO YUDEN 28/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AE-D080137 (7/11) Control name Electrical characteristics Table 5: Link Keys Item Capability Creation of link key - Unit Key Creation of link key - Combination Key Initiate change of link key Accept change of link key (Intentionally left blank) (Intentionally left blank) Accept pairing with Unit Key C.1: Mandatory to support at least One - either (LMP:5/1) OR (LMP:5/2). Prerequisite: 2/3(Encryption supported) Status C.1 C.1 Support Yes Yes Yes Yes No No Yes Table 6: Encryption Item Capability Initiate encryption Accept encryption requests (Intentionally left blank) (Intentionally left blank) Key size negotiation Start encryption, as master Accept start of encryption Stop encryption, as master Accept stop of encryption 10 Encryption Pause/Resume M.1: Mandatory IF (LMP:2/3) - (Encryption) is supported. Status C.1 M.1 M.1 M.1 M.1 M.1 M.1 M.1 Support Yes Yes No No Yes Yes Yes Yes Yes Yes Status Support Yes Yes Status C.1 Support Yes Status M.1 Support Yes Yes Status Support Yes Yes C.1: Mandatory IF (SUMMARY 2-1/5 OR SUMMARY 2-1/6) is claimed, ELSE Optional. Table 7: Clock offset information Item Capability Request clock offset information Respond to clock offset requests Table 8: Slot offset information Prerequisite: 2/4 (Slot offset) Item Capability Send slot offset information C.1: Mandatory IF (LMP:13/1) - (Master/Slave switch) supported, ELSE Optional. Table 9: Timing accuracy information Prerequisite: 2/5 (Timing accuracy) Item Capability Request timing accuracy information Respond to timing accuracy information requests M.1: Mandatory IF (LMP:2/5) - (Timing Accuracy) supported Item Table 10: LM version information Capability Request LM version information Respond to LM version information requests TAIYO YUDEN 29/39 6-Dec.-2008 Ver.0.5 EYTMECS Control No. HD-AE-D080137 TAIYO YUDEN Confidential & Tentative Control name Electrical characteristics (8/11) Table 11: Feature support Item Capability Status Support Request supported features C.1 Yes Respond to supported features requests Yes Request extended features mask C.2 Yes Respond to extended features Request C.2 Yes C.1: Mandatory IF any of the Optional features in (LMP:2/1-3), (LMP:2/5), (LMP:2/7-12), (LMP:2/14-16), (LMP:26/1) is requested by the IUT, ELSE Optional. C.2 Mandatory IF a feature requiring another features page is supported, ELSE Optional. Item Table 12: Name information Request name information Respond to name requests Prerequisite: 2/6(Role switch) Capability Table 14: Detach Detach connection Support Yes Yes Status M.1 Support Yes Yes Status Support Yes Table 13: Role Switch Item Capability Request Master Slave switch Accept Master Slave switch requests M.1 Mandatory IF LMP:(2/6) - (Role Switch) supported Item Status Capability Table 14a: Setting up and Removing Enhanced Data Rate ACL Connection Item Capability Enter Enhanced Data Rate Exit Enhanced Data Rate C.1 Mandatory IF (LMP:2/17) supported, ELSE Excluded. Status C.1 C.1 Table 14b: Setting up and Removing Enhanced Data Rate eSCO Connection Item Capability Enter and exit eSCO using Enhanced Data Rate Packets C.1 Mandatory IF (LMP:2/18) supported, ELSE Excluded. Prerequisite: 2/7 (Hold mode) Support Yes Yes Status C.1 Support Yes Status C.1 Support Yes Yes Yes Yes Table 15: Hold mode Item Capability Force hold mode Request hold mode Respond to hold mode requests Accept forced hold mode C.1: Mandatory IF (LMP:15/1) - (Force hold mode) is supported, ELSE Optional. TAIYO YUDEN 30/39 6-Dec.-2008 Ver.0.5 EYTMECS Control No. HD-AE-D080137 TAIYO YUDEN Confidential & Tentative (9/11) Control name Electrical characteristics Table 16: Sniff mode Item Capability (Intentionally left blank) Request sniff mode Respond to sniff mode requests (rengotiate or reject) (Intentionally left blank) Request un-sniff Accept un-sniff requests Sniff Subrating Mode C.1: Mandatory IF (LMP:16/2) - (Request sniff mode) is supported, ELSE Optional. Status M.1 C.1 M.1 C2 Support No Yes Yes No Yes Yes Yes M.1: Mandatory IF (LMP:2/8) - (Sniff Mode) is supported. C.2 Mandatory IF (SUMMARY 2-1/5 OR SUMMARY 2-1/6) is claimed, ELSE Excluded Table 17: Park mode Item Capability (Intentionally left blank) Request park mode Respond to park mode requests (Intentionally left blank) Set up broadcast scan window Accept changes to the broadcast scan window Modify beacon parameters Accept modification of beacon parameters Request Unpark using PM_ADDR 10 Request Unpark using BD_ADDR 11 Slave requested Unpark 12 Accept Unpark using PM_ADDR 13 Accept Unpark using BD_ADDR M.1: Mandatory IF (LMP:2/9) - (Park Mode) is supported Status M.1 M.1 M.1 C.1 C.1 M.1 M.1 Support No Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes C.1: IF (LMP:17/3) - (Respond to park mode requests) is supported, THEN at least One of (LMP:17/9) - (Unpark using PM_ADDR) OR (LMP:17/10) - (Unpark using BD_ADDR) is Mandatory, ELSE Optional. Prerequisite: 2/13 (RSSI) Prerequisite: 2/10(Power contorol) Table 18: Power Control Item Capability Request to increase power Request to decrease power Respond when max power reached Respond when min power reached M.1: Mandatory IF (LMP:2/13) - (RSSI) is supported M.2: Mandatory IF (LMP:2/10) - (Power Control) is supported Item Table 19: Link supervision timeout Capability Set link supervision timeout value Accept link supervision timeout setting TAIYO YUDEN Status M.1 M.1 M.2 M.2 Support Yes Yes Yes Yes Status Support Yes Yes 31/39 6-Dec.-2008 Ver.0.5 EYTMECS Control No. HD-AE-D080137 Item TAIYO YUDEN Confidential & Tentative (10/11) Control name Electrical characteristics Table 20: Quality of Service Capability Channel quality driven change between DM and DH packet types Force/Request change of Quality of Service Request change of Quality of Service C.1: Mandatory IF support of (LMP:2/11) is stated in the feature request, ELSE Optional. Prerequisite: 2/12 (SCO links) Status Support C.1 Yes Yes Yes Table 21: SCO Links Item Capability Status Initiate SCO links, as Master Initiate SCO links, as Slave Accept SCO links Remove SCO links, as Master C.1 Remove SCO links, as Slave C.2 Negotiate SCO link parameters, as Master C.3 Negotiate SCO link parameters, as Slave C.4 C.1: Mandatory IF (LMP:21/1) - (Initiating SCO links, as Master) is supported, ELSE Optional. Support Yes Yes Yes Yes Yes Yes Yes C.2: Mandatory IF (LMP:21/2) - (Initiating SCO links, as Slave) is supported, ELSE Optional. C.3: Mandatory IF (LMP:21/1) - (Initiating SCO links, as Master) OR (LMP:21/3) - (Accept SCO links) is supported, ELSE Optional. C.4: Mandatory IF (LMP:21/2) - (Initiating SCO links, as Slave) OR (LMP:21/3) - (Accept SCO links) is supported, ELSE Optional. Table 22: Multi-Slot packages Item Capability Status Accept maximum allowed number of slots to be used C.1 Request maximum number of slots to be used C.1 Accept request of maximum number of slots to be used C.1 C.1: Mandatory IF (LMP:2/1) AND/OR (LMP:2/2) is supported in the feature request, ELSE Optional. Item Item Item Table 23: Paging scheme Capability Request page mode to use Accept suggested page mode Request page scan mode to use Accept suggested page scan mode Table 24: Connection Establishment Capability Create connection for higher layers Respond to requests to establish connections for higher layers Indicate that link set-up is completed Table 25: Test Mode Capability Activate test mode Ability to reject activation of test mode if test mode is disabled Control test mode Ability to reject test mode control commands if test mode is disabled. TAIYO YUDEN Support Yes Yes Yes Status Support Yes Yes Yes Yes Status Support Yes Yes Yes Status Support Yes Yes Yes Yes 32/39 6-Dec.-2008 Ver.0.5 EYTMECS Control No. HD-AE-D080137 TAIYO YUDEN Confidential & Tentative (11/11) Control name Electrical characteristics Table 26: Adaptive Frequency Hopping Prerequisite: 2/20(AFH) Item Capability Support of AFH switch as master Support of AFH switch as slave Support of Channel Classification reporting as master Support of Channel Classification reporting as slave Support channel classification from host Support of Channel Classification C.1: Optional IF (LMP:26/6) is supported, ELSE Excluded. Status C.1 C.2 C.3 Support Yes Yes Yes Yes Yes Yes Status Support No No No No C.2: Mandatory IF (LMP:26/6) is supported, ELSE Excluded. C.3: Mandatory IF (LMP:26/1) OR (LMP:26/4) is supported, ELSE Optional. M.1: Mandatory IF (LMP:2/20) - (AFH) supported Item Table 27: This Table is intentionally left blank Capability This line is intentionally blank. This line is intentionally blank. N/A N/A TAIYO YUDEN 33/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-MC-A080137 Control name Circuit Schematic (1/1) Block Diagram CRYSTAL 26 MHz 16KB EEPROM Antenna Baseband Balun filter RF Bluetooth Device Micro controller Connector GND USB D+ USB DPIO4/ BT_PRIORITY /CH_CLK GND(DETECT) /RESET PIO6/ WLAN_ACTIVE /CH_DATA VDD_3.3V PIO1/USB_DETACH 0 GND LDO TAIYO YUDEN 34/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AD-A080137 (1/1) Control name Outline/Appearance Unit: mm, Tolerances unless otherwise specified: +/-0.2mm max0.5 18.2+/-0.1 max5.4 R1.0+/-0.1 2.0+/-0.1 3.5 2.5 15.2+/-0.3 15.0 6.0+/-0.35 3.7+/-0.35 10.0+/-0. 3 7.5 +/-0.3 10 13.0+/-0.1 Shielding case 4.0+/-0.3 28.0+/-0.35 31.0 3.0 Indication label Note: Outline/Appearance data is PRELIMINARY, not guaranteed and subject to change without notice. Please contact Taiyo Yuden for the details of module mountings. TAIYO YUDEN 35/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-AD-B080137 (1/1) Control name Outline/Appearance Indication label Unit: mm 5.45 5.2 R2.9 13.8 TBD 29.0 Material: PET ( UL969 ) / Label color : White TAIYO YUDEN 36/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Control No. HD-BA-A080137 Control name Pin Layout (1/1) Pin Descriptions Terminal No. Terminal name Input/Output Description GND USB_D+ Input/Output USB data (Positive) input-output USB_D- Input/Output USB data (Negative) input-output PIO4/ (BT_PRIORITY/ CH_CLK) Output GND(DETECT) /RESET Input PIO6/ (WLAN_ACTIVE/ CH_DATA) Active low RESET signal with internal weak pull-up Input WLAN_Active/CH_Data input for Co-existence signaling VDD_3.3V Input DC3.3V Power supply PIO1/USB_DETA CH Input DETACH signal input Low USB connect High USB disconnect 10 GND Remark Ground BT_Priority/CH_CLK output for Co-existence signaling Note 2 DETECT Note 3 Note 2 Note 1 Note 2 Ground Notes: 1. Pin8 (VDD_3.3V) is used for power supply of BT module. (MAX 200mA). To fill the standard of “Supply voltage ripple and spike noise”, the capacitor, which has the capacity of 2.2uF or more , should be put in the terminal VDD_3.3V outside as a bypass capacitor . 2. Strength pull-downs (pull-ups) are equivalent to a few kOhms resistance, but are more accurately modeled as a 40uA current drain (source) 3. Weak pull-ups can be thought of 1M Ohm connections to VDD, but are more accurately modeled as a -1uA current source. TAIYO YUDEN 37/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative FCC Regulatory Information CAUTION: To maintain compliance with FCC’s RF exposure guidelines, use only the supplied antenna. Unauthorized antenna, modification, or attachments could damage the transmitter and may violate FCC regulations. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may Cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Canada Regulatory Information Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. L'utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et (2) l'utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. R&TTE Directive Information Hereby Taiyo Yuden Co., Ltd., declares that this Complete Class2 Bluetooth Module (Model No.: EYTMECS) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC The declaration of Conformity may be obtained at; Taiyo Yuden Co., Ltd. 8-1 Sakae-Cho, Takasaki-Shi Gunma, JAPAN 370-8522 Telephone No.) 81-27-324-2313; Fax No.)81-27-324-2314. TAIYO YUDEN 38/39 6-Dec.-2008 Ver.0.5 EYTMECS TAIYO YUDEN Confidential & Tentative Caution Please note that this users manual should not be provided to end-users. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the requirement. Notice - At the installation of our Complete Class2 Bluetooth Module (Model No.: EYTMECS) into the device, following information should be provided with end-user under the responsibility of the manufacture who integrates it into their device. The following sentence has to be displayed on the outside of the device in which the module is installed: "Contains Transmitter Module FCC ID: RYYEYTMECS / IC ID: 4389B-EYTMECS", or "Contains FCC ID: RYYEYTMECS / IC ID: 4389B-EYTMECS " FCC Regulatory information CAUTION: To maintain compliance with FCC’s RF exposure guidelines, use only the supplied antenna. Unauthorized antenna, modification, or attachments could damage the transmitter and may violate FCC regulations. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may Cause undesired operation. Canada Regulatory information Operation is subject to the following two conditions: (3) this device may not cause interference, and (4) this device must accept any interference, including interference that may cause undesired operation of the device. L'utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (3) il ne doit pas produire de brouillage et l'utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. R&TTE Directive information Hereby [Name of manufacture(*)], declares that this [type of equipment(*)] is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC (*) Note: Please write in your company name and type of equipment into [ ]. TAIYO YUDEN 39/39 U.S. Regulatory Wireless Notice Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IMPORTANT NOTE: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2006/8/16 v1.0 This device is intended only for OEM integrators under the following conditions: The transmitter module may not be co-located with any other transmitter or antenna, As long as above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed. IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. End Product Labeling The final end product must be labeled in a visible area with the following: “Contains FCC ID: RYYEYTMECS”. Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual. Canadian Regulatory Wireless Notice This device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the following two conditions: 1) this device may not cause interference and 2) this device must accept any interference, including interference that may cause undesired operation of the device 2006/8/16 v1.0 IMPORTANT NOTE: IC Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. Europe – EU Declaration of Conformity This device complies with the essential requirements of the R&TTE Directive 1999/5/EC. The following test methods have been applied in order to prove presumption of conformity with the essential requirements of the R&TTE Directive 1999/5/EC: EN60950-1:2006 Safety of Information Technology Equipment EN50371 : 2002 Generic standard to demonstrate the compliance of low power electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (10 MHz - 300 GHz) -General public EN 300 328 V1.7.1: (2006-10) Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband Transmission systems; Data transmission equipment operating in the 2,4 GHz ISM band and using spread spectrum modulation techniques; Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive EN 301 489-1 V1.8.1: Electromagnetic compatibility and Radio Spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements EN 301 489-17 V1.2.1 (2002-08) Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for 2,4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment This device is a 2.4 GHz wideband transmission system (transceiver), intended for use in all EU member states and EFTA countries, except in France and Italy where restrictive use applies. 2006/8/16 v1.0 In Italy the end-user should apply for a license at the national spectrum authorities in order to obtain authorization to use the device for setting up outdoor radio links and/or for supplying public access to telecommunications and/or network services. This device may not be used for setting up outdoor radio links in France and in some areas the RF output power may be limited to 10 mW EIRP in the frequency range of 2454 – 2483.5 MHz. For detailed information the end-user should contact the national spectrum authority in France. 0560 Česky [Czech] Dansk [Danish] Deutsch [German] Eesti [Estonian] English Español [Spanish] Ελληνική [Greek] Français [French] Italiano [Italian] Latviski [Latvian] Lietuvių [Lithuanian] Nederlands [Dutch] Malti [Maltese] 2006/8/16 [Jméno výrobce] tímto prohlašuje, že tento [typ zařízení] je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES. Undertegnede [fabrikantens navn] erklærer herved, at følgende udstyr [udstyrets typebetegnelse] overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. Hiermit erklärt [Name des Herstellers], dass sich das Gerät [Gerätetyp] in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet. Käesolevaga kinnitab [tootja nimi = name of manufacturer] seadme [seadme tüüp = type of equipment] vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. Hereby, [name of manufacturer], declares that this [type of equipment] is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Por medio de la presente [nombre del fabricante] declara que el [clase de equipo] cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ [name of manufacturer] ΗΛ ΝΕΙ ΟΤΙ [type of equipment] ΣΥΜΜΟΡΦ ΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙ ΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΙΑΤΑΞΕΙΣ ΤΗΣ Ο ΗΓΙΑΣ 1999/5/ΕΚ. Par la présente [nom du fabricant] déclare que l'appareil [type d'appareil] est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Con la presente [nome del costruttore] dichiara che questo [tipo di apparecchio] è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Ar šo [name of manufacturer / izgatavotāja nosaukums] deklarē, ka [type of equipment / iekārtas tips] atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiem. Šiuo [manufacturer name] deklaruoja, kad šis [equipment type] atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Hierbij verklaart [naam van de fabrikant] dat het toestel [type van toestel] in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Hawnhekk, [isem tal-manifattur], jiddikjara li dan [il-mudel tal-prodott] jikkonforma mal-ħtiāijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 1999/5/EC. v1.0 Magyar [Hungarian] Polski [Polish] Português [Portuguese] Slovensko [Slovenian] Slovensky [Slovak] Suomi [Finnish] Svenska [Swedish] Alulírott, [gyártó neve] nyilatkozom, hogy a [... típus] megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak. Niniejszym [nazwa producenta] oświadcza, Ŝe [nazwa wyrobu] jest zgodny z zasadniczymi wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999/5/EC. [Nome do fabricante] declara que este [tipo de equipamento] está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. [Ime proizvajalca] izjavlja, da je ta [tip opreme] v skladu z bistvenimi zahtevami in ostalimi relevantnimi določili direktive 1999/5/ES. [Meno výrobcu] týmto vyhlasuje, že [typ zariadenia] spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES. [Valmistaja = manufacturer] vakuuttaa täten että [type of equipment = laitteen tyyppimerkintä] tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. Härmed intygar [företag] att denna [utrustningstyp] står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. 經型式認證合格之低功率射頻電機,非經許可,公司 加大功率或變更原設計之特性及功能 商號或使用者均不得擅自變更頻率 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停 用,並改善至無干擾時方得繼續使用 前項合法通信,指依電信法規定作業之無線電通信 低功率射頻電機須忍受合法通信或工業 科學及醫療用電波輻射性電機設備之干擾 2006/8/16 v1.0
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Print high-res Create Date : 2008:12:08 13:28:13+09:00 Modify Date : 2009:01:21 04:30:55-08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2009:01:21 04:30:55-08:00 Producer : Antenna House PDF Driver V3.2MR4 (3.2.5) sn-pro Format : application/pdf Document ID : uuid:efab5ef3-5629-441e-b260-61c9b14a9a8b Instance ID : uuid:a29ce35b-be6a-4c67-97d4-277f1b78781e Page Count : 44EXIF Metadata provided by EXIF.tools