TAKAYA TR3-C202-A0-1 RFID Reader/Writer User Manual 09 UserManual

TAKAYA Corporation RFID Reader/Writer 09 UserManual

09.UserManual

                                                        User’s Manual TR3-C202-A0-1 Manual  No.TDR-MNL-C202-A0-1-EN-100
Manual No.TDR-MNL-C202-A0-1-EN-100    TAKAYA RFID TR3 Series  Introduction  Thank you for purchasing a TR3-C202-A0-1 RFID READER/WRITER.  Be sure to read this manual before using the product. After reading it, store the manual in a convenient place for future reference.
Manual No.TDR-MNL-C202-A0-1-EN-100    TAKAYA RFID TR3 Series  Regulations and Standards  FCC  This product is conform to the FCC standards. FCC Rules (Federal Communications Commission) This product complies with Part 15 Subpart C of the FCC Rules. FCC ID : MK4TR3-C202-A0-1  FCC NOTICE This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.  FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  The following sentence has to be displayed on the outside of the device in which the transmitter module is installed : “Contains FCC ID: MK4TR3-C202-A0-1”  Japan Radio Law  Equipment using high frequencies: Inductive Reading/Writing Communications Equipment Conforming standards: Inductive Reading/Writing Communications Equipment;   Standard: ARIB STD-T82 Tags  This product can communicate the standard tags of ISO/IEC15693 and ISO/IEC18000-3(Mode1). Supports  Manufacturer Tag-it HF-I  Texas Instruments my-d  Infineon Technologies I・CODE SLI  NXP Semiconductors MB89R118  FUJITSU Japan   RoHS is support  Restriction of Hazardous Substances Waste  Dispose of the Products as industrial waste.
Manual No.TDR-MNL-C202-A0-1-EN-100    TAKAYA RFID TR3 Series  Safety Precautions  The following symbols are used in this manual to indicate precautions that must be observed to ensure safe use of this product. The precautions provided here contain important safety information. Be sure to observe these precautions.    The following signal words are used in this manual.  Failure to comply with a WARNING may result in serious injury or death.  Failure  to  comply  with  a  CAUTION  may  result  in  injury  to  the operator, or damage to the items involved.       Be sure to observe the following precautions to ensure safe use of the Products. Decomposition of this product and cable, repair, remodeling, please strictly prohibited. There is the possibility of fire or electric shock injuries.  This product is using the RFID reader writer radio equipment. Therefore, depending on where the applications you use may affect medical equipment. To minimize the impact of medical equipment for use, please observe the following countermeasure. The Japan Automatic Identification Systems Association (JAISA) guidelines are as follows: RFID antennas from implanted cardiac pacemakers or other medical devices please 22cm apart. We recommend that you paste "RFID sticker" at equipment.          Be sure to observe the following precautions to ensure safe use of the Products. Installation and storage environment 1. Do not use the Products in sunlight. 2. Do not use the Products in environment of spray of water, oil or chemicals. 3. Do not use the Products in environments with flammable, explosive, or corrosive gasses. 4. Do not use the Products in environment of hot humid. 5. Do not use the Products in environment of vibration or shock. 6. Do not use the Products in environment of condensation. 7. Do not use the Products in environment of around the metal is covered. 8. Do not use the Products in environment of high temperature. 9. Do not use the Products in environment that has a device that generates magnetic field and shock voltage. 10. Do not use the Products in unstable place. 11. If there is failure, discontinue use immediately, please contact us or the distributor.  Installation 1. Turn off the power before installation or removing. 2. The following effects may not work correctly.   ・  Near 13.56MHz radio device   ・  Near speakers , Inverter, motor and Plasma Display 3. The communication range may vary due to environment and conditions.   ← RFID Sticker
Manual No.TDR-MNL-C202-A0-1-EN-100    TAKAYA RFID TR3 Series  Contents 1 Product Overview ...................................................................................................1 1.1 Features ........................................................................................................................................ 1 2 Names of Parts and Functions ..................................................................................2 2.1 TR3-C202-A0-1.............................................................................................................................. 2 2.2 Antenna......................................................................................................................................... 3 2.2.1 TR3-A202................................................................................................................................... 3 2.2.2 TR3-A302................................................................................................................................... 4 2.2.3 TR3-A401................................................................................................................................... 4 3 Installation and connection ......................................................................................5 3.1 Installation into a host device.......................................................................................................... 5 3.1.1 Installation from the Front............................................................................................................. 5 3.1.2 Installation from the Back ............................................................................................................. 5 3.2 Antenna installation into a host device............................................................................................. 6 3.2.1 Screw holes................................................................................................................................. 6 3.2.2 Guide ......................................................................................................................................... 6 3.3 Connection .................................................................................................................................... 7 3.3.1 Attaching the Cable and Antenna.................................................................................................... 7 3.3.2 Direct connection to the Host Device Interface................................................................................. 7 3.3.3 Using the interface board to connect to the Host Device Interface ....................................................... 8 4 Specifications .........................................................................................................9 4.1 TR3-C202-A0-1.............................................................................................................................. 9 4.2 Antenna........................................................................................................................................14 4.2.1 TR3-A202..................................................................................................................................14 4.2.2 TR3-A302..................................................................................................................................15 4.2.3 TR3-A401..................................................................................................................................16 4.3 Cable............................................................................................................................................17 4.3.1 TR3-AC-1A-***.........................................................................................................................17 4.3.2 TR3-AC-2A-***.........................................................................................................................17 5 Maintenance ........................................................................................................ 18 Revision History......................................................................................................... 19
Manual No.TDR-MNL-C202-A0-1-EN-100 1  Product Overview 1.1  Features 1 TAKAYA RFID TR3 Series  1 Product Overview    1.1 Features This product uses the 13.56MHz frequency. This product is the electromagnetic induction type non-contact IC can read and write RFID tag data. This Product is designed to be embedded and integrated within OEM devices and finished products such as label printers, cashless payment terminals or any other device that can benefit from integrated RFID capabilities.                           ■ Conform to international standards ISO/IEC15693 and ISO/IEC18000-3(Mode1) is supports.  ■ Rich Products  Various interface RS-232C, USB, TCP/IP.  Antennas of various sizes  ■ Software  TR3-series common communication protocol  Software Development Kit  ■ Useful  Continuous inventory mode UID of the tag automatically sends Host Device.  RDLoop mode UID or User Data of the tag automatically sends Host Device.         For more information please refer to the TR3-PROTOCOL manual.  ■ Environmentally EU RoHS(2002/95/EC) Support  Antenna CPU  Memory RF-ASIC READER/WRITER Load Settings Save Settings Interface Tags   Host Device Interface RS-232C、LAN(TCP/IP)、USB Communications UART(CMOS Level)
Manual No.TDR-MNL-C202-A0-1-EN-100 2  Names of Parts and Functions 2.1  TR3-C202-A0-1 2 TAKAYA RFID TR3 Series  2 Names of Parts and Functions    2.1 TR3-C202-A0-1                                No  Name  Description ① CN1  This connector is for connection to the host. ② FCC ID stickers  Production numbers, will be 8-digit serial number.        ③ LED1  Displays the status of this product. ④ CN2  Connect the antenna cable. ⑤ Screw holes  M3 holes  ⑤ ① ② ③ ④ Model Name Serial number:********(F)
Manual No.TDR-MNL-C202-A0-1-EN-100 2  Names of Parts and Functions 2.2  Antenna 3 TAKAYA RFID TR3 Series  2.2 Antenna 2.2.1 TR3-A202                      No  Name  Description ① CN1  Connect the antenna cable. ② Nameplate  Production numbers, will be 8-digit serial number.     ③ Inspection mark   ④ Screw holes  M3 holes  ④ ① ② ③ Model Name Serial number:********(F)
Manual No.TDR-MNL-C202-A0-1-EN-100 2  Names of Parts and Functions 2.2  Antenna 4 TAKAYA RFID TR3 Series  2.2.2 TR3-A302                   No  Name  Description ① Inspection mark   ② Screw holes  M3 holes ③ Nameplate  Production numbers, will be 8-digit serial number.     ④ CN1  Connect the antenna cable.  2.2.3 TR3-A401             No  Name  Description ① CN1  Connect the antenna cable. ② Nameplate  Production numbers, will be 8-digit serial number.     ③ Inspection mark     ② ③ ④ ① Model Name Serial number:********(F) ① ② ③ Model Name Serial number:********(F)
Manual No.TDR-MNL-C202-A0-1-EN-100 3  Installation and connection 3.1  Installation into a host device 5 TAKAYA RFID TR3 Series  3 Installation and connection   3.1 Installation into a host device  3.1.1 Installation from the Front                             3.1.2 Installation from the Back                     Host Device M3 Screw Four, M3 holes Four, M3 holes M3 Screw Screw hole depth : 3mm Host Device
Manual No.TDR-MNL-C202-A0-1-EN-100 3  Installation and connection 3.2  Antenna installation into a host device 6 TAKAYA RFID TR3 Series  3.2 Antenna installation into a host device  3.2.1 Screw holes                     3.2.2 Guide TR3-A401 is recommended that you set up a guide on fixed-like the figure below.                TR3-A401 M3 Screw Host Device
Manual No.TDR-MNL-C202-A0-1-EN-100 3  Installation and connection 3.3  Connection 7 TAKAYA RFID TR3 Series  3.3 Connection This product will connect with the antenna and antenna cables.   This product connects with Host Device that direct connection or connect using our interface.  3.3.1 Attaching the Cable and Antenna                       3.3.2 Direct connection to the Host Device Interface     Please prepare to the interface harness.                     Host Device Interface harness TR3-C202-A0-1  TR3-C202-A0-1  Antenna Antenna Cable Host Device Interface Host Device
Manual No.TDR-MNL-C202-A0-1-EN-100 3  Installation and connection 3.3  Connection 8 TAKAYA RFID TR3 Series Host Device  3.3.3 Using the interface board to connect to the Host Device Interface     Interface board, please contact us.                                      TR3-C202-A0-1  Interface Cable Interface board Interface harness Host Device Interface
Manual No.TDR-MNL-C202-A0-1-EN-100 4  Specifications 4.1  TR3-C202-A0-1 9 TAKAYA RFID TR3 Series  4 Specifications    4.1 TR3-C202-A0-1 ■  Specifications Specifications Item  Parameter Japan Radio Law  ARIB STD-T82 FCC  FCC Part 15 Subpart C FCC ID : MK4TR3-C202-A0-1 Applicable Standards RoHS  EU RoHS(2002/95/EC) Supports Carrier frequency  13.56MHz ±50ppm(Ta=25℃) or less Transmit  power  or power range  10∼100mW ± 20%(Ta=25℃, VCC=5.0V) Standards  ISO/IEC 15693、ISO/IEC18000-3(Mode1) Tags  Tag-it HF-I, my-d, I・CODE SLI, MB89R118(※1) Data rate    Speed  Data rate 1/4  26.48kbps Reader/Writer⇒Tag  1/256  1.65kbps Tag⇒Reader/Writer  26.69kbps   Modulation      Parameter Reader/Writer⇒Tag  ASK 10%(※2) / ASK 100% Tag⇒Reader/Writer  ASK, FSK   Radio Frequency Anti-collision  Support     ※1:Tag-it HF-I is a registered trademark of Texas Instruments Incorporated.                   my-d is a registered trademark of Infineon Technologies AG.          I・CODE SLI is a registered trademark of NXP Semiconductors.                   MB89R118 is a registered trademark of FUJITSU Japan.   ※2:initialization
Manual No.TDR-MNL-C202-A0-1-EN-100 4  Specifications 4.1  TR3-C202-A0-1 10 TAKAYA RFID TR3 Series  Specifications Item  Parameter Command  Please refer to the TR3-Protocol-Manual. Host Interface  UART(CMOS) Item  Parameter Speed  9600bps 19200bps(※2) 38400bps Data bits  8 Parity  None Stop bit  1 Flow control  None   Controll LED1  1pc (3 colors, red/green/orange) CN1  Connector : JST S10B-PH-SM4-TB(LF)(SN) Housing : JST PHR-10 Contact : JST SPH-002T-P0.5S  Pin assignment Pin No.  Symbol  Function 1  VCC  Power 2  VCC  Power 3  GND  GND 4  GND  GND 5  Rx  Received data signal 6  Tx  Transmitted data signal 7  VCC2  Power output 8  IO1  Input/Output  or  Detection  signal output H : Detection 9  IO2  Input/Output or Trigger input L : Trigger ON 10  IO3  Input/Output   Connector CN2  Connector : JST S2B-PH-SM4-TB(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S  Pin assignment Pin No.  Symbol  Function 1  RF  Analog signal 2  GND  GND     ※2:initialization
Manual No.TDR-MNL-C202-A0-1-EN-100 4  Specifications 4.1  TR3-C202-A0-1 11 TAKAYA RFID TR3 Series  Specifications Item  Parameter Dimensions (W x D x H)  63.8 x 61 x 14.3mm Weight  approx. 80g Mechanical data Installation  M3 Screw   Screw is not included. Electrical data  Power  Supply Voltage  :5V±10% Current consumption  :approx. 120mA Carrier off  :approx. 35mA Power down mode  :approx. 24mA Consumption  :max 1.0W  Temperature Operating range  0 to 55 degree Humidity  Operating range  30 to 80%RH Temperature Storage range  0 to 55 degree Ambient Conditions Humidity Storage range  30 to 80%RH Other  Accessories  None
Manual No.TDR-MNL-C202-A0-1-EN-100 4  Specifications 4.1  TR3-C202-A0-1 12 TAKAYA RFID TR3 Series  ■  Dimensions                                                        Unit:mm Tolerance:±0.3mm ( )is Recommended Dimension Screw hole depth:3mm
Manual No.TDR-MNL-C202-A0-1-EN-100 4  Specifications 4.1  TR3-C202-A0-1 13 TAKAYA RFID TR3 Series  ■  Connections Names  Model  Notes TR3-A202 TR3-A302 Antenna TR3-A401  TR3-AC-1A-***  *** puts the cable length. 9cm ~ 50cm cable are available. Cable TR3-AC-2A-***  *** puts the cable length. 10cm ~ 3m cable are available. TR3-IF-1C  RS232C interface TR3-IF-N1  TCP/IP interface Interface board TR3-IF-U1  USB interface  ■  Electrical Characteristics(CN1) Item  Condition  MIN  TYP  MAX  Unit H input voltage  RX,IO1,IO2,IO3  2.5    5.0  V L input voltage  RX,IO1,IO2,IO3  0    1.0  V H output voltage  IOH=-5mA,-20mA  3.0      V L output voltage  IOL=5mA,20mA      2.0  V Pull-up resistor    25.0  50.0  100.0  kΩ ・TX, RX, IO1, IO2 and IO3 is, Pull-up resistor has been connected. ・TX, RX, IO1, IO2 and IO3 is, 100 ohm resistor has been connected.         Output port, LED is not driven. If the LED drive, please use the digital transistors.
Manual No.TDR-MNL-C202-A0-1-EN-100 4  Specifications 4.2  Antenna 14 TAKAYA RFID TR3 Series  4.2 Antenna 4.2.1 TR3-A202 ■  Specifications Specifications Item  Parameter Applicable Standards  RoHS  EU RoHS(2002/95/EC) Support Resonant frequency  13.56MHz ±40kHz(Ta=25℃) Antenna Communication distance  Max 10cm (Communication distance depends on the environment.) Connector  CN1  Connector : JST S2B-PH-SM4-TB(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S  Pin assignment Pin No.  Symbol  Function 1  RF  Analog signal 2  GND  GND    Dimensions (W x D x H)  60 x 65 x 9.1 mm Weight  approx. 11g Mechanical data Installation  M3 Screw   Screw is not included. Temperature Operating range  0 to 55 degree Humidity Operating range  30 to 80%RH Temperature Storage range  0 to 55 degree Ambient Conditions Humidity Storage range  30 to 80%RH Other  Accessories  RFID Sticker 1 sheet   Model Name : SEL41400L  ■  Dimensions   Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm
Manual No.TDR-MNL-C202-A0-1-EN-100 4  Specifications 4.2  Antenna 15 TAKAYA RFID TR3 Series  4.2.2 TR3-A302 ■  Specifications Specifications Item  Parameter Applicable Standards  RoHS  EU RoHS(2002/95/EC) Support Resonant frequency  13.56MHz ±40kHz(Ta=25℃) Antenna Communication distance  Max 7cm (Communication distance depends on the environment.) Connector  CN1  Connector : JST S2B-PH-SM4-TB(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S  Pin assignment Pin No.  Symbol  Function 1  RF  Analog signal 2  GND  GND    Dimensions (W x D x H)  15 x 52.5 x 9.1 mm Weight  approx. 3g Mechanical data Installation  M3 Screw   Screw is not included. Temperature Operating range  0 to 55 degree Humidity Operating range  30 to 80%RH Temperature Storage range  0 to 55 degree Ambient Conditions Humidity Storage range  30 to 80%RH Other  Accessories  RFID Sticker 1 sheet   Model Name : SEL41400L  ■  Dimensions                    Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm
Manual No.TDR-MNL-C202-A0-1-EN-100 4  Specifications 4.2  Antenna 16 TAKAYA RFID TR3 Series  4.2.3 TR3-A401 ■  Specifications Specifications Item  Parameter Applicable Standards  RoHS  EU RoHS(2002/95/EC) Support Resonant frequency  13.56MHz ±40kHz(Ta=25℃) Antenna Communication distance  Max 5cm (Communication distance depends on the environment.) Connector  CN1  Connector : JST S2B-PH-K-S(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S  Pin assignment Pin No.  Symbol  Function 1  RF  Analog signal 2  GND  GND    Dimensions (W x D x H)  15 x 30 x 9.1 mm Weight  approx. 2g Mechanical data Installation  M3 Screw   Screw is not included. Temperature Operating range  0 to 55 degree Humidity Operating range  30 to 80%RH Temperature Storage range  0 to 55 degree Ambient Conditions Humidity Storage range  30 to 80%RH Other  Accessories  RFID Sticker 1 sheet   Model Name : SEL41400L  ■  Dimensions                      Unit:mm Tolerance:±1mm Substrate thickness : 1.0mm
Manual No.TDR-MNL-C202-A0-1-EN-100 4  Specifications 4.3  Cable 17 TAKAYA RFID TR3 Series  4.3 Cable  4.3.1 TR3-AC-1A-***  ■  Model Name      ■  Specifications Item  Parameter RoHS  EU RoHS(2002/95/EC) Support Linetype  Twisted pair cable Connector  PH-PH Cable loss  9cm : approx. 0.061dB 50cm : approx. 0.337dB  ■  Dimensions             4.3.2 TR3-AC-2A-***  ■  Model Name      ■  Specifications Item  Parameter RoHS  EU RoHS(2002/95/EC) Support Linetype  Coaxial cable 1.5D-2V Connector  PH-PH Cable loss  10cm : approx. 0.043dB 3m    : approx. 0.255dB  ■  Dimensions            ( )is Recommended Dimension (Cable length)  TR3-AC-2A-*** Enter the cable length(Unit:mm) 100∼3M ( )is Recommended Dimension (Cable length)  TR3-AC-1A-*** Enter the cable length(Unit:mm) 090∼500
Manual No.TDR-MNL-C202-A0-1-EN-100  18 TAKAYA RFID TR3 Series  5 Maintenance    This product is mainly used in electronic components and semiconductors.     Therefore,  the  long-term stable operation,  the  environment  and  conditions  are expected  to  defect,  as shown below.  • Device degradation due to overvoltage and overcurrent. • Device degradation due to high temperature and long-term stress. • Poor contact of the connector and cause deterioration of insulation by moisture or dust. • Connector corrosion by corrosive gases.   In order to use this product at its best, please conduct routine or periodic inspections. Item  Maintenance  Criteria Temperature  Temperature Operating range 0 to 55 degree Humidity  Humidity Operating range  30 to 80%RH Enclosure rating  Check the dusty  None Ambient conditions Corrosive  Check the corrosion  None Input  Check the voltage Power  Voltage fluctuation  Check the Voltage fluctuation Input Voltage : DC5V±10% Check the Screw Product  Check the Connector  Checking and verifying Attachment Cable  Check the Cable break  None Performance  Check the Performance  Work
Manual No.TDR-MNL-C202-A0-1-EN-100  19 TAKAYA RFID TR3 Series  Revision History  Revision code Date  Revised contents 1.00  2010/10/28 Original production
 20                                                        [URL]  http://www.takaya.co.jp/ [Mail]  rfid@takaya.co.jp