TAKAYA TR3-C202-A0-1 RFID Reader/Writer User Manual 09 UserManual
TAKAYA Corporation RFID Reader/Writer 09 UserManual
TAKAYA >
09.UserManual
User’s Manual TR3-C202-A0-1 Manual No.TDR-MNL-C202-A0-1-EN-100 Introduction Thank you for purchasing a TR3-C202-A0-1 RFID READER/WRITER. Be sure to read this manual before using the product. After reading it, store the manual in a convenient place for future reference. Manual No.TDR-MNL-C202-A0-1-EN-100 TAKAYA RFID TR3 Series Regulations and Standards FCC This product is conform to the FCC standards. FCC Rules (Federal Communications Commission) This product complies with Part 15 Subpart C of the FCC Rules. FCC ID : MK4TR3-C202-A0-1 FCC NOTICE This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The following sentence has to be displayed on the outside of the device in which the transmitter module is installed : “Contains FCC ID: MK4TR3-C202-A0-1” Japan Radio Law Equipment using high frequencies: Inductive Reading/Writing Communications Equipment Conforming standards: Inductive Reading/Writing Communications Equipment; Standard: ARIB STD-T82 Tags This product can communicate the standard tags of ISO/IEC15693 and ISO/IEC18000-3(Mode1). Supports Manufacturer Tag-it HF-I Texas Instruments my-d Infineon Technologies NXP Semiconductors I・CODE SLI MB89R118 FUJITSU Japan RoHS is support Restriction of Hazardous Substances Waste Dispose of the Products as industrial waste. Manual No.TDR-MNL-C202-A0-1-EN-100 TAKAYA RFID TR3 Series Safety Precautions The following symbols are used in this manual to indicate precautions that must be observed to ensure safe use of this product. The precautions provided here contain important safety information. Be sure to observe these precautions. The following signal words are used in this manual. Failure to comply with a WARNING may result in serious injury or death. Failure to comply with a CAUTION may result in injury to the operator, or damage to the items involved. Be sure to observe the following precautions to ensure safe use of the Products. Decomposition of this product and cable, repair, remodeling, please strictly prohibited. There is the possibility of fire or electric shock injuries. This product is using the RFID reader writer radio equipment. Therefore, depending on where the applications you use may affect medical equipment. To minimize the impact of medical equipment for use, please observe the following countermeasure. The Japan Automatic Identification Systems Association (JAISA) guidelines are as follows: RFID antennas from implanted cardiac pacemakers or other medical devices please 22cm apart. We recommend that you paste "RFID sticker" at equipment. ← RFID Sticker Be sure to observe the following precautions to ensure safe use of the Products. Installation and storage environment 1. Do not use the Products in sunlight. 2. Do not use the Products in environment of spray of water, oil or chemicals. 3. Do not use the Products in environments with flammable, explosive, or corrosive gasses. 4. Do not use the Products in environment of hot humid. 5. Do not use the Products in environment of vibration or shock. 6. Do not use the Products in environment of condensation. 7. Do not use the Products in environment of around the metal is covered. 8. Do not use the Products in environment of high temperature. 9. Do not use the Products in environment that has a device that generates magnetic field and shock voltage. 10. Do not use the Products in unstable place. 11. If there is failure, discontinue use immediately, please contact us or the distributor. Installation 1. Turn off the power before installation or removing. 2. The following effects may not work correctly. ・ Near 13.56MHz radio device ・ Near speakers , Inverter, motor and Plasma Display 3. The communication range may vary due to environment and conditions. Manual No.TDR-MNL-C202-A0-1-EN-100 TAKAYA RFID TR3 Series Contents Product Overview ................................................................................................... 1 1.1 Features ........................................................................................................................................ 1 Names of Parts and Functions .................................................................................. 2 2.1 TR3-C202-A0-1.............................................................................................................................. 2 2.2 Antenna......................................................................................................................................... 3 2.2.1 TR3-A202................................................................................................................................... 3 2.2.2 TR3-A302................................................................................................................................... 4 2.2.3 TR3-A401................................................................................................................................... 4 Installation and connection ...................................................................................... 5 3.1 Installation into a host device.......................................................................................................... 5 3.1.1 Installation from the Front............................................................................................................. 5 3.1.2 Installation from the Back ............................................................................................................. 5 3.2 Antenna installation into a host device............................................................................................. 6 3.2.1 Screw holes................................................................................................................................. 6 3.2.2 Guide ......................................................................................................................................... 6 3.3 Connection .................................................................................................................................... 7 3.3.1 Attaching the Cable and Antenna.................................................................................................... 7 3.3.2 Direct connection to the Host Device Interface................................................................................. 7 3.3.3 Using the interface board to connect to the Host Device Interface ....................................................... 8 Specifications ......................................................................................................... 9 4.1 TR3-C202-A0-1.............................................................................................................................. 9 4.2 Antenna........................................................................................................................................14 4.2.1 TR3-A202..................................................................................................................................14 4.2.2 TR3-A302..................................................................................................................................15 4.2.3 TR3-A401..................................................................................................................................16 4.3 Cable............................................................................................................................................17 4.3.1 TR3-AC-1A-***.........................................................................................................................17 4.3.2 TR3-AC-2A-***.........................................................................................................................17 Maintenance ........................................................................................................ 18 Revision History ......................................................................................................... 19 Manual No.TDR-MNL-C202-A0-1-EN-100 TAKAYA RFID TR3 Series 1 Product Overview 1.1 Features 1 Product Overview 1.1 Features This product uses the 13.56MHz frequency. This product is the electromagnetic induction type non-contact IC can read and write RFID tag data. This Product is designed to be embedded and integrated within OEM devices and finished products such as label printers, cashless payment terminals or any other device that can benefit from integrated RFID capabilities. Host Device Interface RS-232C、LAN(TCP/IP)、USB Interface UART(CMOS Level) READER/WRITER Load Settings CPU Memory Save Settings Communications Antenna RF-ASIC Tags ■ Conform to international standards ISO/IEC15693 and ISO/IEC18000-3(Mode1) is supports. ■ Rich Products Various interface RS-232C, USB, TCP/IP. Antennas of various sizes ■ Software TR3-series common communication protocol Software Development Kit ■ Useful Continuous inventory mode UID of the tag automatically sends Host Device. RDLoop mode UID or User Data of the tag automatically sends Host Device. For more information please refer to the TR3-PROTOCOL manual. ■ Environmentally EU RoHS(2002/95/EC) Support Manual No.TDR-MNL-C202-A0-1-EN-100 TAKAYA RFID TR3 Series 2 Names of Parts and Functions 2.1 TR3-C202-A0-1 2 Names of Parts and Functions 2.1 TR3-C202-A0-1 ① ② ③ ④ ⑤ No ① ② Name CN1 FCC ID stickers Description This connector is for connection to the host. Production numbers, will be 8-digit serial number. Model Name Serial number:********(F) ③ ④ ⑤ LED1 CN2 Screw holes Displays the status of this product. Connect the antenna cable. M3 holes Manual No.TDR-MNL-C202-A0-1-EN-100 TAKAYA RFID TR3 Series 2 Names of Parts and Functions 2.2 Antenna 2.2 Antenna 2.2.1 TR3-A202 ① ② ③ ④ No ① ② Name CN1 Nameplate Description Connect the antenna cable. Production numbers, will be 8-digit serial number. Model Name Serial number:********(F) ③ ④ Inspection mark Screw holes M3 holes Manual No.TDR-MNL-C202-A0-1-EN-100 TAKAYA RFID TR3 Series 2 Names of Parts and Functions 2.2 Antenna 2.2.2 TR3-A302 ① ② ④ ③ No ① ② ③ Name Inspection mark Screw holes Nameplate Description M3 holes Production numbers, will be 8-digit serial number. Model Name Serial number:********(F) ④ 2.2.3 CN1 TR3-A401 ① No ① ② Connect the antenna cable. Name CN1 Nameplate ② ③ Description Connect the antenna cable. Production numbers, will be 8-digit serial number. Model Name Serial number:********(F) ③ Inspection mark Manual No.TDR-MNL-C202-A0-1-EN-100 TAKAYA RFID TR3 Series 3.1 3 Installation and connection Installation into a host device 3 Installation and connection 3.1 Installation into a host device 3.1.1 Installation from the Front Four, M3 holes M3 Screw Host Device 3.1.2 Installation from the Back Four, M3 holes Screw hole depth : 3mm Host Device M3 Screw Manual No.TDR-MNL-C202-A0-1-EN-100 TAKAYA RFID TR3 Series 3.2 3 Installation and connection Antenna installation into a host device 3.2 Antenna installation into a host device 3.2.1 Screw holes M3 Screw 3.2.2 Guide TR3-A401 is recommended that you set up a guide on fixed-like the figure below. Host Device TR3-A401 Manual No.TDR-MNL-C202-A0-1-EN-100 TAKAYA RFID TR3 Series 3 Installation and connection 3.3 Connection 3.3 Connection This product will connect with the antenna and antenna cables. This product connects with Host Device that direct connection or connect using our interface. 3.3.1 Attaching the Cable and Antenna Host Device TR3-C202-A0-1 Antenna Antenna Cable 3.3.2 Direct connection to the Host Device Interface Please prepare to the interface harness. Host Device TR3-C202-A0-1 Host Device Interface Interface harness Manual No.TDR-MNL-C202-A0-1-EN-100 TAKAYA RFID TR3 Series 3 Installation and connection 3.3 Connection 3.3.3 Using the interface board to connect to the Host Device Interface Interface board, please contact us. Host Device TR3-C202-A0-1 Interface Cable Host Device Interface Interface board Interface harness Manual No.TDR-MNL-C202-A0-1-EN-100 TAKAYA RFID TR3 Series 4 Specifications 4.1 TR3-C202-A0-1 4 Specifications 4.1 TR3-C202-A0-1 ■ Specifications Specifications Item Applicable Japan Radio Law Standards FCC Radio Frequency Parameter ARIB STD-T82 FCC Part 15 Subpart C FCC ID : MK4TR3-C202-A0-1 RoHS EU RoHS(2002/95/EC) Supports Carrier frequency 13.56MHz ±50ppm(Ta=25℃) or less Transmit power or 10∼100mW ± 20%(Ta=25℃, VCC=5.0V) power range Standards ISO/IEC 15693、ISO/IEC18000-3(Mode1) Tags Tag-it HF-I, my-d, I・CODE SLI, MB89R118(※1) Data rate Speed Data rate 1/4 26.48kbps Reader/Writer⇒Tag 1/256 1.65kbps 26.69kbps Tag⇒Reader/Writer Modulation Reader/Writer⇒Tag Tag⇒Reader/Writer Parameter ASK 10%(※2) ASK, FSK / ASK 100% Anti-collision Support ※1:Tag-it HF-I is a registered trademark of Texas Instruments Incorporated. my-d is a registered trademark of Infineon Technologies AG. I・CODE SLI is a registered trademark of NXP Semiconductors. MB89R118 is a registered trademark of FUJITSU Japan. ※2:initialization Manual No.TDR-MNL-C202-A0-1-EN-100 TAKAYA RFID TR3 Series 4 Specifications 4.1 TR3-C202-A0-1 Specifications Item Controll Command Host Interface Connector LED1 CN1 Parameter Please refer to the TR3-Protocol-Manual. UART(CMOS) Item Parameter Speed 9600bps 19200bps(※2) 38400bps Data bits Parity None Stop bit Flow control None 1pc (3 colors, red/green/orange) Connector : JST S10B-PH-SM4-TB(LF)(SN) Housing : JST PHR-10 Contact : JST SPH-002T-P0.5S Pin assignment Pin No. CN2 Symbol VCC VCC GND GND Rx Tx VCC2 IO1 IO2 10 IO3 Function Power Power GND GND Received data signal Transmitted data signal Power output Input/Output or Detection signal output H : Detection Input/Output or Trigger input L : Trigger ON Input/Output Connector : JST S2B-PH-SM4-TB(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S Pin assignment Pin No. Symbol RF GND Function Analog signal GND ※2:initialization Manual No.TDR-MNL-C202-A0-1-EN-100 10 TAKAYA RFID TR3 Series 4 Specifications 4.1 TR3-C202-A0-1 Specifications Item Mechanical Dimensions data (W x D x H) Weight Installation Electrical data Power Ambient Conditions Temperature Operating range Humidity Operating range Temperature Storage range Humidity Storage range Accessories Other Manual No.TDR-MNL-C202-A0-1-EN-100 Parameter 63.8 x 61 x 14.3mm approx. 80g M3 Screw Screw is not included. Supply Voltage Current consumption Carrier off Power down mode Consumption 0 to 55 degree :5V±10% :approx. 120mA :approx. 35mA :approx. 24mA :max 1.0W 30 to 80%RH 0 to 55 degree 30 to 80%RH None 11 TAKAYA RFID TR3 Series 4 Specifications 4.1 TR3-C202-A0-1 ■ Dimensions Unit:mm Tolerance:±0.3mm ( )is Recommended Dimension Screw hole depth:3mm Manual No.TDR-MNL-C202-A0-1-EN-100 12 TAKAYA RFID TR3 Series 4 Specifications 4.1 TR3-C202-A0-1 ■ Connections Names Antenna Cable Model Notes TR3-A202 TR3-A302 TR3-A401 TR3-AC-1A-*** *** puts the cable length. 9cm ~ 50cm cable are available. *** puts the cable length. 10cm ~ 3m cable are available. RS232C interface TCP/IP interface USB interface TR3-AC-2A-*** Interface board TR3-IF-1C TR3-IF-N1 TR3-IF-U1 ■ Electrical Characteristics(CN1) Item Condition MIN TYP H input voltage RX,IO1,IO2,IO3 2.5 L input voltage RX,IO1,IO2,IO3 H output voltage IOH=-5mA,-20mA 3.0 L output voltage IOL=5mA,20mA Pull-up resistor 25.0 50.0 ・TX, RX, IO1, IO2 and IO3 is, Pull-up resistor has been connected. ・TX, RX, IO1, IO2 and IO3 is, 100 ohm resistor has been connected. Output port, LED is not driven. If the LED drive, please use the digital transistors. Manual No.TDR-MNL-C202-A0-1-EN-100 13 MAX 5.0 1.0 2.0 100.0 Unit kΩ TAKAYA RFID TR3 Series 4 Specifications 4.2 Antenna 4.2 Antenna 4.2.1 TR3-A202 ■ Specifications Specifications Item Applicable RoHS Standards Antenna Resonant frequency Communication distance Connector CN1 Parameter EU RoHS(2002/95/EC) Support 13.56MHz ±40kHz(Ta=25℃) Max 10cm (Communication distance depends on the environment.) Connector : JST S2B-PH-SM4-TB(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S Pin assignment Pin No. Mechanical data Ambient Conditions Other Dimensions (W x D x H) Weight Installation Temperature Operating range Humidity Operating range Temperature Storage range Humidity Storage range Accessories Symbol RF GND Function Analog signal GND 60 x 65 x 9.1 mm approx. 11g M3 Screw Screw is not included. 0 to 55 degree 30 to 80%RH 0 to 55 degree 30 to 80%RH RFID Sticker 1 sheet Model Name : SEL41400L ■ Dimensions Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm Manual No.TDR-MNL-C202-A0-1-EN-100 14 TAKAYA RFID TR3 Series 4 Specifications 4.2 Antenna 4.2.2 TR3-A302 ■ Specifications Specifications Item Applicable RoHS Standards Antenna Resonant frequency Communication distance Connector CN1 Parameter EU RoHS(2002/95/EC) Support 13.56MHz ±40kHz(Ta=25℃) Max 7cm (Communication distance depends on the environment.) Connector : JST S2B-PH-SM4-TB(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S Pin assignment Pin No. Mechanical data Ambient Conditions Other Dimensions (W x D x H) Weight Installation Temperature Operating range Humidity Operating range Temperature Storage range Humidity Storage range Accessories Symbol RF GND Function Analog signal GND 15 x 52.5 x 9.1 mm approx. 3g M3 Screw Screw is not included. 0 to 55 degree 30 to 80%RH 0 to 55 degree 30 to 80%RH RFID Sticker 1 sheet Model Name : SEL41400L ■ Dimensions Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm Manual No.TDR-MNL-C202-A0-1-EN-100 15 TAKAYA RFID TR3 Series 4 Specifications 4.2 Antenna 4.2.3 TR3-A401 ■ Specifications Specifications Item Applicable RoHS Standards Antenna Resonant frequency Communication distance Connector CN1 Parameter EU RoHS(2002/95/EC) Support 13.56MHz ±40kHz(Ta=25℃) Max 5cm (Communication distance depends on the environment.) Connector : JST S2B-PH-K-S(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S Pin assignment Pin No. Mechanical data Ambient Conditions Other Dimensions (W x D x H) Weight Installation Temperature Operating range Humidity Operating range Temperature Storage range Humidity Storage range Accessories Symbol RF GND Function Analog signal GND 15 x 30 x 9.1 mm approx. 2g M3 Screw Screw is not included. 0 to 55 degree 30 to 80%RH 0 to 55 degree 30 to 80%RH RFID Sticker 1 sheet Model Name : SEL41400L ■ Dimensions Unit:mm Tolerance:±1mm Substrate thickness : 1.0mm Manual No.TDR-MNL-C202-A0-1-EN-100 16 TAKAYA RFID TR3 Series 4 Specifications 4.3 Cable 4.3 Cable 4.3.1 TR3-AC-1A-*** ■ Model Name TR3-AC-1A-*** Enter the cable length(Unit:mm) 090∼500 ■ Specifications Item RoHS Linetype Connector Cable loss Parameter EU RoHS(2002/95/EC) Support Twisted pair cable PH-PH 9cm : approx. 0.061dB 50cm : approx. 0.337dB ■ Dimensions (Cable length) 4.3.2 )is Recommended Dimension TR3-AC-2A-*** ■ Model Name TR3-AC-2A-*** Enter the cable length(Unit:mm) 100∼3M ■ Specifications Item RoHS Linetype Connector Cable loss Parameter EU RoHS(2002/95/EC) Support Coaxial cable 1.5D-2V PH-PH 10cm : approx. 0.043dB 3m : approx. 0.255dB ■ Dimensions (Cable length) Manual No.TDR-MNL-C202-A0-1-EN-100 17 )is Recommended Dimension TAKAYA RFID TR3 Series 5 Maintenance This product is mainly used in electronic components and semiconductors. Therefore, the long-term stable operation, the environment and conditions are expected to defect, as shown below. • Device degradation due to overvoltage and overcurrent. • Device degradation due to high temperature and long-term stress. • Poor contact of the connector and cause deterioration of insulation by moisture or dust. • Connector corrosion by corrosive gases. In order to use this product at its best, please conduct routine or periodic inspections. Item Maintenance Criteria Temperature Temperature Operating range 0 to 55 degree Humidity Humidity Operating range 30 to 80%RH Ambient Enclosure conditions Check the dusty None rating Corrosive Check the corrosion None Input Check the voltage Power Input Voltage : DC5V±10% Voltage Check the Voltage fluctuation fluctuation Check the Screw Product Checking and verifying Attachment Check the Connector Cable Check the Cable break None Performance Check the Performance Work Manual No.TDR-MNL-C202-A0-1-EN-100 18 TAKAYA RFID TR3 Series Revision History Revision code 1.00 Date 2010/10/28 Revised contents Original production Manual No.TDR-MNL-C202-A0-1-EN-100 19 TAKAYA RFID TR3 Series [URL] [Mail] http://www.takaya.co.jp/ rfid@takaya.co.jp 20
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2010:11:04 20:19:02+09:00 Creator : Xelo PDFLibrary Modify Date : 2010:11:04 20:19:02+09:00 Producer : クセロPDF2 v2.10 Page Count : 25EXIF Metadata provided by EXIF.tools