TAKAYA TR3-L4D01-24 RFID READER/WRITER User Manual Rev 2
TAKAYA Corporation RFID READER/WRITER Users Manual Rev 2
TAKAYA >
Users Manual Rev 2
User’s Manual TR3-L4D01-24 Manual No.TDR-MNL-L4D01-24-EN-100 Introduction Thank you for purchasing a TR3-L4D01-24 RFID READER/WRITER. Be sure to read this manual before using the product. After reading it, store the manual in a convenient place for future reference. Manual No.TDR-MNL-L4D01-24-EN-090 TAKAYA RFID TR3 Series Regulations and Standards FCC This product is conform to the FCC standards. FCC Rules (Federal Communications Commission) This product complies with Part 15 Subpart B and C of the FCC Rules. FCC ID : MK4TR3-L4D01-24 FCC NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment must be professionally installed to ensure compliance with Part 15. Antennas not allowed are strictly prohibited for use with This equipment. This equipment is to be professionally installed by professional service trained personnel only. SMB sockets are provided in the equipment for connecting the external antenna. The following sentence has to be displayed on the outside of the device in which the transmitter module is installed : “Contains FCC ID: MK4TR3-L4D01-24” This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter within a host device, except in accordance with FCC multi-transmitter product procedures. The final system integrator must ensure there is no instruction provided in the user manual or customer documentation indicating how to install or remove the transmitter module except such device has implemented two-ways authentication between module and the host system. FCC §15.27 b) - Special Accessories – If a device requiring special accessories is installed by or under the supervision of the party marketing the device, it is the responsibility of that party to install the equipm ent using the special accessories. For equipment requiring professional installation, it is not necessary for the responsible party to market the special accessories with the equipment. However, the need to use the special accessories m ust be detailed in the instruction manual, and it is the responsibility of the installer to provide and to install the required accessories. Manual No.TDR-MNL-L4D01-24-EN-090 TAKAYA RFID TR3 Series Japan Radio Law Equipment using high frequencies: Inductive Reading/Writing Communications Equipment Conforming standards: Inductive Reading/Writing Communications Equipment; Standard: ARIB STD-T82 RoHS is support Restriction of Hazardous Substances Waste Dispose of the Products as industrial waste. Manual No.TDR-MNL-L4D01-24-EN-090 TAKAYA RFID TR3 Series Safety Precautions The following symbols are used in this manual to indicate precautions that must be observed to ensure safe use of this product. The precautions provided here contain important safety information. Be sure to observe these precautions. The following signal words are used in this manual. Failure to comply with a WARNING may result in serious injury or death. Failure to comply with a CAUTION may result in injury to the operator, or damage to the items involved. Be sure to observe the following precautions to ensure safe use of the Products. Decomposition of this product and cable, repair, remodeling, please strictly prohibited. There is the possibility of fire or electric shock injuries. This product is using the RFID reader writer radio equipment. Therefore, depending on where the applications you use may affect medical equipment. To minimize the impact of medical equipment for use, please observe the following countermeasure. The Japan Automatic Identification Systems Association (JAISA) guidelines are as follows: RFID antennas from implanted cardiac pacemakers or other medical devices please 22cm apart. We recommend that you paste "RFID sticker" at equipment. ← RFID Sticker Be sure to observe the following precautions to ensure safe use of the Products. Installation and storage environment 1. Do not use the Products in sunlight. 2. Do not use the Products in environment of spray of water, oil or chemicals. 3. Do not use the Products in environments with flammable, explosive, or corrosive gasses. 4. Do not use the Products in environment of hot humid. 5. Do not use the Products in environment of vibration or shock. 6. Do not use the Products in environment of condensation. 7. Do not use the Products in environment of around the metal is covered. 8. Do not use the Products in environment of high temperature. 9. Do not use the Products in environment that has a device that generates magnetic field and shock voltage. 10. Do not use the Products in unstable place. 11. If there is failure, discontinue use immediately, please contact us or the distributor. Installation 1. Turn off the power before installation or removing. 2. The following effects may not work correctly. ・ Near 13.56MHz radio device ・ Near speakers , Inverter, motor and Plasma Display 3. The communication range may vary due to environment and conditions. Manual No.TDR-MNL-L4D01-24-EN-090 TAKAYA RFID TR3 Series Contents Product Overview ...................................................................................................... 1 1.1 Names of Parts and Functions ..................................................................................... 2 2.1 2.2 Features .............................................................................................................................................. 1 TR3-L4D01-24 .................................................................................................................................... 2 Antenna .............................................................................................................................................. 4 Setting and connection ................................................................................................ 8 3.1 Setting ................................................................................................................................................. 8 3.1.1 DeskTop ........................................................................................................................................... 8 3.1.2 Wall Mounting .................................................................................................................................. 8 3.2 Antenna installation into a host device ................................................................................................. 9 3.2.1 Installation example by Screw holes ................................................................................................... 9 3.3 Connection ......................................................................................................................................... 11 3.3.1 Attaching the Cable and Antenna ....................................................................................................... 11 3.3.2 Direct connection to the Host Device Interface. .................................................................................. 11 Specifications ........................................................................................................... 12 4.1 TR3-L4D01-24 .................................................................................................................................. 12 4.2 Antenna ............................................................................................................................................ 16 4.2.1 TR3-CA033 .................................................................................................................................... 16 4.2.2 TR3-CA034 .................................................................................................................................... 18 4.2.3 TR3-CA044 .................................................................................................................................... 20 4.2.4 TR3-CA045 .................................................................................................................................... 22 4.3 Coupler Cable ................................................................................................................................... 24 4.4 Antenna Cable................................................................................................................................... 25 4.4.1 WIR42696 ...................................................................................................................................... 25 4.4.2 WIR42763 ...................................................................................................................................... 25 4.4.3 09019M16 ...................................................................................................................................... 26 Accessories .............................................................................................................. 27 5.1 5.2 AC Adapter(TR3-PWR-19V-2) .......................................................................................................... 27 RS232C Cross-cable(CB-232C-3) ...................................................................................................... 28 Maintenance ............................................................................................................ 29 Revision History ............................................................................................................. 30 Manual No.TDR-MNL-L4D01-24-EN-090 TAKAYA RFID TR3 Series 1 Product Overview 1.1 Features 1 Product Overview 1.1 Features This product uses the 13.56MHz frequency. This product is the electromagnetic induction type non-contact IC can read and write RFID tag data. This Product is designed to be embedded and integrated within OEM devices and finished products such as label printers, cashless payment terminals or any other device that can benefit from integrated RFID capabilities. Host Device Interface RS-232C LED/BUZZER Interface Module UART(CMOS Level) CPU Communications RF-ASIC Antenna Multiplexer Tags Antenna Antenna TR3-L201W4(READER/WRITER) Module) TR3-L4D01-24 Block Diagram ■ Conform to international standards ISO/IEC15693 and ISO/IEC18000-3(Mode1) is supports. ■ Software TR3-series common communication protocol Software Development Kit ■ Multiplexer Select the RF output. ■ Useful Continuous inventory mode UID of the tag automatically sends Host Device. RDLoop mode UID or User Data of the tag automatically sends Host Device. For more information please refer to the TR3-PROTOCOL manual. ■ Environmentally EU RoHS(2002/95/EC) Support Manual No.TDR-MNL-L4D01-24-EN-100 TAKAYA RFID TR3 Series 2 Names of Parts and Functions 2.1 TR3-L4D01-24 2 Names of Parts and Functions 2.1 TR3-L4D01-24 ③ ⑨ ① ② ④ ⑤ ⑥ ⑦ ⑨ Manual No.TDR-MNL-L4D01-24-EN-100 TAKAYA RFID TR3 Series 2 No ① ② ③ Name LED Nameplate RFID sticker ANT1 to ANT24 ④ ⑤ ⑥ ⑦ Power Button DC Jack Connector FCC ID sticker Names of Parts and Functions 2.1 TR3-L4D01-24 Description Displays the status of this product. Production numbers. Specify that the RFID radio waves are radiated. Connect the Antenna cable. Please connect from ANT1. Power ON/OFF. DC +19V input. Connect the RS-232C cable. Production numbers, will be 8-digit serial number. Model Name Serial number:******** ⑧ ⑨ TÜV mark Screw holes TÜV certification mark 6.5mm×13mm mounting holes. Manual No.TDR-MNL-L4D01-24-EN-100 TAKAYA RFID TR3 Series 2 Names of Parts and Functions 2.2 Antenna 2.2 Antenna 2.2.1 TR3-CA033 CA033 is combined by 2 loop sub antennas and a coupler board. ④ Sub Antenna 1 TR3-CA033-1 Sub Antenna 2 TR3-CA033-2 Coupler Board 09019P04 ① ② ⑤ ⑤ ① ① ② ② ⑥ ⑥ ⑥ ③ ⑤ ① No ① ② ③ ④ ⑤ Name Screw holes CN (PH) CN (SMA) ferrite sheet Nameplate Description M3 holes. Connect the coupler board. Connect the antenna cable. Paste on TR3-CA033-1 reverse side. Production numbers, will be 8-digit serial number. Model Name Serial number:******** ⑥ Inspection mark Manual No.TDR-MNL-L4D01-24-EN-100 TAKAYA RFID TR3 Series 2 Names of Parts and Functions 2.2 Antenna 2.2.2 TR3-CA034 TR3-CA034 is combined by loop antenna and a coupler board. Antenna TR3-CA034 Coupler board 09019P05 ① ② ⑥ ① ⑤ ① ④ ⑥ Antenna TR3-CA034 ③ ⑤ ② ① Reverse side No ① ② ③ ④ ⑤ Name Screw holes CN (PH) CN (SMA) ferrite sheet Nameplate Description M3 holes. Connect the coupler board. Connect the antenna cable. Paste on TR3-CA034 surface side. Production numbers, will be 8-digit serial number. Model Name Serial number:******** ⑥ Inspection mark Manual No.TDR-MNL-L4D01-24-EN-100 TAKAYA RFID TR3 Series 2 Names of Parts and Functions 2.2 Antenna 2.2.3 TR3-CA044 TR3-CA044 is combined by loop antenna and a coupler board. Antenna TR3-CA044 Coupler board 09019P16 ① ② ① ① ② ⑤ Antenna TR3-CA044 ④ ③ ⑤ ④ ① Reverse side No ① ② ③ ④ Name Screw holes CN (PH) CN (SMA) Nameplate Description M3 holes. Connect the coupler board. Connect the antenna cable. Production numbers, will be 8-digit serial number. Model Name Serial number:******** ⑤ Inspection mark Manual No.TDR-MNL-L4D01-24-EN-100 TAKAYA RFID TR3 Series 2 Names of Parts and Functions 2.2 Antenna 2.2.4 TR3-CA045 TR3-CA045 is combined by loop antenna and a coupler board. Antenna TR3-CA045 Coupler board 09019P14 ① ② ① ② ① ⑤ ⑤ ④ Antenna TR3-CA045 ③ ④ ① Reverse side No ① ② ③ ④ Name Screw holes CN (PH) CN (SMA) Nameplate Description M3 holes. Connect the coupler board. Connect the antenna cable. Production numbers, will be 8-digit serial number. Model Name Serial number:******** ⑤ Inspection mark Manual No.TDR-MNL-L4D01-24-EN-100 TAKAYA RFID TR3 Series 3 Setting and connection 3.1 Setting 3 Setting and connection This RFID Reader/Writer product is to be professionally installed by authorized, qualified and service-trained installation personnel only. 3.1 Setting 3.1.1 DeskTop Don’t drop the product. . Injury may result if the product falls or is dropped. 3.1.2 Wall Mounting Must be fastened securely the product with the screws. Don’t install to the high place. Injury may result if the product falls or is dropped. Screw Manual No.TDR-MNL-L4D01-24-EN-100 TAKAYA RFID TR3 Series 3.2 3 Setting and connection Antenna installation into a host device 3.2 Antenna installation into a host device Incorporate the antenna in enclosure by all means. 3.2.1 Installation example by Screw holes ・TR3-CA033 M3 Screw M3 Screw ・TR3-CA034 Manual No.TDR-MNL-L4D01-24-EN-100 TAKAYA RFID TR3 Series 3.2 3 Setting and connection Antenna installation into a host device ・TR3-CA044 M3 Screw M3 Screw ・TR3-CA045 Manual No.TDR-MNL-L4D01-24-EN-100 10 TAKAYA RFID TR3 Series 3 Setting and connection 3.3 Connection 3.3 Connection This product will connect with the antenna and antenna cables. This product connects with Host Device with the cable. Type of ferrite core and number of turns are specified by compliance for FCC. When providing this product, ferrite cores are already installed in cables. Don’t change the type of ferrite core and number of turns of the cables (Power supply cable, RS-232C cable, Antenna cables). Don’t connect the combination of other than indicated in the table below. 3.3.1 Attaching the Cable and Antenna Host Device TR3-L4D01-24 Antenna Antenna Cable Antenna TR3-CA033 WIR42696 and ferrite core TR3-CA034 WIR42696 and ferrite core TR3-CA044 WIR42763 and ferrite core TR3-CA045 WIR42763 and ferrite core 3.3.2 Antenna Cable 09019M16 (Ferrite core around the wire.) 09019M16 (Ferrite core around the wire.) 09019M16 (Ferrite core around the wire.) 09019M16 (Ferrite core around the wire.) Direct connection to the Host Device Interface. TR3-L4D01-24 Host Device Host Device Interface Interface harness Manual No.TDR-MNL-L4D01-24-EN-100 11 TAKAYA RFID TR3 Series 4 Specifications 4.1 TR3-L4D01-24 4 Specifications 4.1 TR3-L4D01-24 Specifications Item Applicable Japan Radio Law Standards FCC Radio Frequency Parameter ARIB STD-T82 FCC Part 15 Subpart B,C FCC ID : MK4TR3-L4D01-24 RoHS EU RoHS(2002/95/EC) Supports Safety standard EN60950-1(TÜV) Carrier frequency 13.56MHz ±50ppm(Ta=25℃) or less Transmit power or 4W ± 10%(Ta=25℃, VCC=19V) power range Standards ISO/IEC 15693、ISO/IEC18000-3(Mode1) Tags Tag-it HF-I, my-d, I・CODE SLI Data rate ・ISO/IEC 15693,ISO/IEC18000-3(Mode1) Speed Data rate 1/4 26.48kbps Product⇒Tag 1/256 1.65kbps 26.69kbps Tag⇒Product Modulation ・ISO/IEC 15693,ISO/IEC18000-3(Mode1) Parameter ASK 10% Product⇒Tag FSK Tag⇒Product ※1:Tag-it HF-I is a registered trademark of Texas Instruments Incorporated. my-d is a registered trademark of Infineon Technologies AG. I・CODE SLI is a registered trademark of NXP Semiconductors. Manual No.TDR-MNL-L4D01-24-EN-100 12 TAKAYA RFID TR3 Series 4 Specifications 4.1 TR3-L4D01-24 Specifications Item Anti-collision Parameter Standards ISO/IEC 15693 ISO/ISC 18000-3 (Mode1) Host Interface RS-232C Item Speed Parameter 9600bps 19200bps 38400bps(※2) None None Data bits Parity Stop bit Flow control Control LED BUZZER Antenna Connector Anti-collision YES 1 LED (green) 1 BUZZER Connector SMB(J)×24 Symbol RF GND Center Contact Shell Connector RS-232C Connector D-SUB 9Pin Pin assignment Pin No. DC JACK Function RF output GND Symbol NC Rx Tx NC GND NC NC NC NC Function Not Connected Received data signal Transmitted data signal Not Connected GND Not Connected Not Connected Not Connected Not Connected Connector 9.5×external diameterφ5.5 internal diameterφ2.1 Pin assignment Center electrode External electrode Symbol GND VCC Function GND Power Input ※2:initialization Manual No.TDR-MNL-L4D01-24-EN-100 13 TAKAYA RFID TR3 Series 4 Specifications 4.1 TR3-L4D01-24 Specifications Item Mechanical Dimensions data (W x D x H) Weight Electrical Power data Ambient Conditions Accessories Temperature Operating range Humidity Operating range Temperature Storage range Humidity Storage range AC Adaptor RS232C Cross-cable Manual No.TDR-MNL-L4D01-24-EN-100 Parameter 260 x 336 x 88.6mm (Protrusions except) approx. 4.5kg Supply Voltage Current consumption Carrier off Consumption 0 to 40 degree :DC+19V±10% :approx. 1.2mA :approx. 520mA :max 24W 30 to 80%RH 0 to 55 degree 30 to 80%RH TR3-PWR-19V-2 CB-232C-3 14 TAKAYA RFID TR3 Series 4 Specifications 4.1 TR3-L4D01-24 ■ Dimensions Unit:mm Tolerance:±1.0mm ( )is Recommended Dimension Manual No.TDR-MNL-L4D01-24-EN-100 15 TAKAYA RFID TR3 Series 4 Specifications 4.2 Antenna 4.2 Antenna 4.2.1 TR3-CA033 ■ Specifications Specifications Item Applicable RoHS Standards Antenna Resonant frequency Antenna Type Connector CN1 Parameter EU RoHS(2002/95/EC) Support 13.56MHz(Ta=25℃) LOOP ANTENNA Connector : SMA(J) Pin assignment Center Contact Shell Mechanical data Dimensions (W x D x H) Weight Ambient Conditions Other Temperature Operating range Humidity Operating range Temperature Storage range Humidity Storage range Accessories Symbol RF GND Function RF input GND TR3-CA033-1:64 (W)×80(D)×7.7(H)mm TR3-CA033-2:64 (W)×80(D)×7.1(H)mm 09019P04:55 (W)×80(D)×15.6(H)mm TR3-CA033-1:25g TR3-CA033-2:17g 09019P04:47g 0 to 40 degree 30 to 80%RH 0 to 55 degree 30 to 80%RH Two Twisted pare cables Model Name : TR3-AC-1A-120 ①1.5D-2V SMA(P)-SMB(J) + Ferrite core Model Name : WIR42696 + ZCAT13250530A(1 turn) ②1.5D-2V SMB(P)-SMB(P) + Ferrite core Model Name : 09019M16 ( E04SR0200935A (3 turn)) ② ① Manual No.TDR-MNL-L4D01-24-EN-100 16 TAKAYA RFID TR3 Series 4 Specifications 4.2 Antenna ■ Dimensions ○TR3-CA033-1 Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm ○TR3-CA033-2 Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm ○09019P04 Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm Manual No.TDR-MNL-L4D01-24-EN-100 17 TAKAYA RFID TR3 Series 4 4.2.2 TR3-CA034 ■ Specifications Specifications Item Applicable RoHS Standards Antenna Resonant frequency Antenna Type Connector CN1 Specifications 4.2 Antenna Parameter EU RoHS(2002/95/EC) Support 13.56MHz(Ta=25℃) LOOP ANTENNA Connector : SMA(J) Pin assignment Center Contact Shell Mechanical data Dimensions (W x D x H) Weight Ambient Conditions Temperature Operating range Humidity Operating range Temperature Storage range Humidity Storage range Accessories Other Symbol RF GND Function RF input GND TR3-CA034:238 (W)×68(D)×7.7(H)mm 09019P05:55 (W)×80(D)×15.6(H)mm TR3-CA034:65g 09019P05:47g 0 to 40 degree 30 to 80%RH 0 to 55 degree 30 to 80%RH Two Twisted pare cables Model Name : TR3-AC-1A-120 ①1.5D-2V SMA(P)-SMB(J) + Ferrite core Model Name : WIR42696 + ZCAT13250530A(1 turn) ②1.5D-2V SMB(P)-SMB(P) + Ferrite core Model Name : 09019M16 ( E04SR0200935A (3 turn)) ② ① Manual No.TDR-MNL-L4D01-24-EN-100 18 TAKAYA RFID TR3 Series 4 Specifications 4.2 Antenna ■ Dimensions ○TR3-CA034 Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm ○09019P05 Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm Manual No.TDR-MNL-L4D01-24-EN-100 19 TAKAYA RFID TR3 Series 4 4.2.3 TR3-CA044 ■ Specifications Specifications Item Applicable RoHS Standards Antenna Resonant frequency Antenna Type Connector CN1 Specifications 4.2 Antenna Parameter EU RoHS(2002/95/EC) Support 13.56MHz(Ta=25℃) LOOP ANTENNA Connector : SMA(J) Pin assignment Center Contact Shell Mechanical data Dimensions (W x D x H) Weight Ambient Conditions Temperature Operating range Humidity Operating range Temperature Storage range Humidity Storage range Accessories Other Symbol RF GND Function RF input GND TR3-CA044:433.2 (W)×91.1(D)×7.1(H)mm 09019P16:55 (W)×80(D)×15.6(H)mm TR3-CA044:96g 09019P16:47g 0 to 40 degree 30 to 80%RH 0 to 55 degree 30 to 80%RH Twisted pare cables Model Name : TR3-AC-1A-090 ①1.5D-2V SMA(P)-SMB(J) + Ferrite core Model Name : WIR42763 + E04SR241336A(3 turn) ②1.5D-2V SMB(P)-SMB(P) + Ferrite core Model Name : 09019M16 ( E04SR0200935A (3 turn)) ② ① Manual No.TDR-MNL-L4D01-24-EN-100 20 TAKAYA RFID TR3 Series 4 Specifications 4.2 Antenna ■ Dimensions ○TR3-CA044 433.23 11-Φ3.2 91.11 200 4-R5 5.5 (7.1) Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm ○09019P16 Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm Manual No.TDR-MNL-L4D01-24-EN-100 21 TAKAYA RFID TR3 Series 4 4.2.4 TR3-CA045 ■ Specifications Specifications Item Applicable RoHS Standards Antenna Resonant frequency Antenna Type Connector CN1 Specifications 4.2 Antenna Parameter EU RoHS(2002/95/EC) Support 13.56MHz(Ta=25℃) LOOP ANTENNA Connector : SMA(J) Pin assignment Center Contact Shell Mechanical data Dimensions (W x D x H) Weight Ambient Conditions Temperature Operating range Humidity Operating range Temperature Storage range Humidity Storage range Accessories Other Symbol RF GND Function RF input GND TR3-CA045:424 (W)×84(D)×8.2(H)mm 09019P14:55 (W)×80(D)×15.6(H)mm TR3-CA045:108g 09019P14:47g 0 to 40 degree 30 to 80%RH 0 to 55 degree 30 to 80%RH Twisted pare cables Model Name : TR3-AC-1A-090 ①1.5D-2V SMA(P)-SMB(J) + Ferrite core Model Name : WIR42763 + E04SR200935A(2 turn) ②1.5D-2V SMB(P)-SMB(P) + Ferrite core Model Name : 09019M16 ( E04SR0200935A (3 turn)) ② ① Manual No.TDR-MNL-L4D01-24-EN-100 22 TAKAYA RFID TR3 Series 4 Specifications 4.2 Antenna ■ Dimensions ○TR3-CA045 424 4-R3 84 6.6 (8.2) Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm ○09019P14 Unit:mm Tolerance:±1mm Substrate thickness : 1.6 mm Manual No.TDR-MNL-L4D01-24-EN-100 23 TAKAYA RFID TR3 Series 4 Specifications 4.3 Coupler Cable 4.3 Coupler Cable Coupler Cable (between Antenna to coupler board) TR3-AC-1A-*** Enter the cable length 90mm : 090 120mm : 120 ■ Specifications item RoHS Linetype Connector Cable loss Parameter EU RoHS(2002/95/EC) Support AWG26 PH-PH 90mm : approx. 0.061dB 120mm : approx. 0.081dB ■ Dimensions (Cable Length) ( )is Recommended Dimension Manual No.TDR-MNL-L4D01-24-EN-100 24 TAKAYA RFID TR3 Series 4 Specifications 4.4 Antenna Cable 4.4 Antenna Cable 4.4.1 WIR42696 ■ Specifications item RoHS Linetype Connector Cable loss Parameter EU RoHS(2002/95/EC) Support Coaxial cable 1.5D-2V SMA(P)-SMB(J) approx. 0.043dB ■ Dimensions 500 Unit:mm 4.4.2 WIR42763 ■ Specifications Item RoHS Linetype Connector Cable loss Parameter EU RoHS(2002/95/EC) Support Coaxial cable 1.5D-2V SMA(P)-SMB(J) approx. 0.051dB ■ Dimensions 600 Unit:mm Manual No.TDR-MNL-L4D01-24-EN-100 25 TAKAYA RFID TR3 Series 4 Specifications 4.4 Antenna Cable 4.4.3 09019M16 ■ Specifications Item RoHS Linetype Connector Cable loss Ferrite core Parameter EU RoHS(2002/95/EC) Support Coaxial cable 1.5D-2V SMB(P)-SMB(P) approx. 0.16dB E04SR0200935A(3 turn) ■ Dimensions WIR42696 or WIR42763 Side TR3-L4D01-24 Side (1730) Unit:mm ( )is Recommended Dimension Manual No.TDR-MNL-L4D01-24-EN-100 26 TAKAYA RFID TR3 Series 5.1 5 Accessories AC Adapter(TR3-PWR-19V-2) 5 Accessories 5.1 AC Adapter(TR3-PWR-19V-2) ■ Specifications Specifications Item Applicable EMI Standards COMPLY SAFETY STANDARDS RoHS AC INPUT VOLTAGE FREQUENCY DC OUTPUT DC OUTPUT VOLTAGE RANGE LOAD CURRENT OUTPUT PLUG TYPE Mechanical data Wight Dimensions Cable length Ambient Conditions Temperature Operating range Humidity Operating range Temperature Storage range Humidity Storage range Ferrite core Parameter FCC class B, CISPR 22 class B UL60950, IEC60950, CSA22.2 No.60950, LPS:Limited Power Source, PSE EU RoHS(2002/95/EC) Support AC100V to AC240V 50 to 60Hz DC19.0V±5% 3.15A CENTER MINUS 9.5×external diameterφ5.5 internal diameterφ2.1 approx. 500g 53(W) x 118.4(D) x 33.5(H)mm (Cords are not included) DC Plug side:approx. 1170mm AC Plug side:approx. 1700mm 0 to 40 degree 10 to 85%RH -25 to 60 degree 10 to 95%RH MSFC 13K(4 turn) 2pcs ■ Dimension Ferrite Core Unit:mm )is Recommended Dimension Manual No.TDR-MNL-L4D01-24-EN-100 27 TAKAYA RFID TR3 Series 5.2 5 Accessories RS232C Cross-cable(CB-232C-3) 5.2 RS232C Cross-cable(CB-232C-3) Type of ferrite core and number of turns are specified by compliance for FCC. Don’t change and remove the ferrite core. Don’t uses except the bundled RS232C Cross-cable. ■ Specifications Specifications RoHS Connector screw Cable length Ferrite core Connection Parameter EU RoHS(2002/95/EC) Support D-sub 9Pin Inch screw approx. 4.5m ZCAT17300730A(1 turn) Cross-cable ■ Dimension (4500) Host Device ( ex.PC ) Side TR3-L4D01-24 Side Unit:mm )is Recommended Dimension Manual No.TDR-MNL-L4D01-24-EN-100 28 TAKAYA RFID TR3 Series 6 Maintenance This product is mainly used in electronic components and semiconductors. Therefore, the long-term stable operation, the environment and conditions are expected to defect, as shown below. • Device degradation due to overvoltage and overcurrent. • Device degradation due to high temperature and long-term stress. • Poor contact of the connector and cause deterioration of insulation by moisture or dust. • Connector corrosion by corrosive gases. In order to use this product at its best, please conduct routine or periodic inspections. Item Maintenance Criteria Temperature Temperature Operating range 0 to 40 degree Humidity Humidity Operating range 30 to 80%RH Ambient Enclosure conditions Check the dusty None rating Corrosive Check the corrosion None Input Check the voltage Power Input Voltage : DC19V±10% Voltage Check the Voltage fluctuation fluctuation Check the Screw Product Checking and verifying Attachment Check the Connector Cable Check the Cable break None Performance Check the Performance Work Manual No.TDR-MNL-L4D01-24-EN-100 29 TAKAYA RFID TR3 Series Revision History Revision code 1.00 Date 2015/05/08 Revised contents Original production Manual No.TDR-MNL-L4D01-24-EN-100 30 TAKAYA RFID TR3 Series [URL] [Mail] http://www.takaya.co.jp/ rfid@takaya.co.jp 31
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 37 Language : ja-JP Tagged PDF : Yes Author : RF事業推進部 嶋津 Creator : Microsoft® Word 2010 Create Date : 2015:05:08 20:11:43+09:00 Modify Date : 2015:05:08 20:11:43+09:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools