TAKAYA TR3-L4D01-24 RFID READER/WRITER User Manual Rev 2

TAKAYA Corporation RFID READER/WRITER Users Manual Rev 2

Users Manual Rev 2

Download: TAKAYA TR3-L4D01-24 RFID READER/WRITER User Manual Rev 2
Mirror Download [FCC.gov]TAKAYA TR3-L4D01-24 RFID READER/WRITER User Manual Rev 2
Document ID2619071
Application IDop6+5avy4HE7ejvQeV6Qnw==
Document DescriptionUsers Manual Rev 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize130.81kB (1635124 bits)
Date Submitted2015-05-19 00:00:00
Date Available2015-05-20 00:00:00
Creation Date2015-05-08 20:11:43
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2015-05-08 20:11:43
Document TitleUsers Manual Rev 2
Document CreatorMicrosoft® Word 2010
Document Author: RF事業推進部 嶋津

User’s Manual
TR3-L4D01-24
Manual No.TDR-MNL-L4D01-24-EN-100
Introduction
Thank you for purchasing a TR3-L4D01-24 RFID READER/WRITER.
Be sure to read this manual before using the product.
After reading it, store the manual in a convenient place for future reference.
Manual No.TDR-MNL-L4D01-24-EN-090
TAKAYA RFID TR3 Series
Regulations and Standards
FCC
This product is conform to the FCC standards.
FCC Rules (Federal Communications Commission)
This product complies with Part 15 Subpart B and C of the FCC Rules.
FCC ID : MK4TR3-L4D01-24
FCC NOTICE
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC WARNING
Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
This equipment must be professionally installed to ensure compliance with Part 15.
Antennas not allowed are strictly prohibited for use with This equipment.
This equipment is to be professionally installed by professional service trained personnel only.
SMB sockets are provided in the equipment for connecting the external antenna.
The following sentence has to be displayed on the outside of the device in which the transmitter module
is installed : “Contains FCC ID: MK4TR3-L4D01-24”
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any
other antenna or transmitter within a host device,
except in accordance with FCC multi-transmitter product procedures.
The final system integrator must ensure there is no instruction provided in the user manual or customer
documentation indicating how to install or remove the transmitter module except such device has
implemented two-ways authentication between module and the host system.
FCC §15.27 b) - Special Accessories –
If a device requiring special accessories is installed by or under the supervision of the party marketing
the device, it is the responsibility of that party to install the equipm ent using the special accessories.
For equipment requiring professional installation, it is not necessary for the responsible party to market
the special accessories with the equipment.
However, the need to use the special accessories m ust be detailed in the instruction manual, and it is
the responsibility of the installer to provide and to install the required accessories.
Manual No.TDR-MNL-L4D01-24-EN-090
TAKAYA RFID TR3 Series
Japan Radio Law
Equipment using high frequencies: Inductive Reading/Writing Communications Equipment
Conforming standards: Inductive Reading/Writing Communications Equipment;
Standard: ARIB STD-T82
RoHS is support
Restriction of Hazardous Substances
Waste
Dispose of the Products as industrial waste.
Manual No.TDR-MNL-L4D01-24-EN-090
TAKAYA RFID TR3 Series
Safety Precautions
The following symbols are used in this manual to indicate precautions that must be observed to ensure safe use of
this product. The precautions provided here contain important safety information. Be sure to observe these
precautions.
The following signal words are used in this manual.
Failure to comply with a WARNING may result in serious injury or
death.
Failure to comply with a CAUTION may result in injury to the
operator, or damage to the items involved.
Be sure to observe the following precautions to ensure safe use of the Products.
Decomposition of this product and cable, repair, remodeling, please strictly prohibited. There is the
possibility of fire or electric shock injuries.
This product is using the RFID reader writer radio equipment. Therefore, depending on where the
applications you use may affect medical equipment. To minimize the impact of medical equipment for use,
please observe the following countermeasure. The Japan Automatic Identification Systems Association
(JAISA) guidelines are as follows: RFID antennas from implanted cardiac pacemakers or other medical
devices please 22cm apart. We recommend that you paste "RFID sticker" at equipment.
← RFID Sticker
Be sure to observe the following precautions to ensure safe use of the Products.
Installation and storage environment
1. Do not use the Products in sunlight.
2. Do not use the Products in environment of spray of water, oil or chemicals.
3. Do not use the Products in environments with flammable, explosive, or corrosive gasses.
4. Do not use the Products in environment of hot humid.
5. Do not use the Products in environment of vibration or shock.
6. Do not use the Products in environment of condensation.
7. Do not use the Products in environment of around the metal is covered.
8. Do not use the Products in environment of high temperature.
9. Do not use the Products in environment that has a device that generates magnetic field and shock voltage.
10. Do not use the Products in unstable place.
11. If there is failure, discontinue use immediately, please contact us or the distributor.
Installation
1. Turn off the power before installation or removing.
2. The following effects may not work correctly.
・ Near 13.56MHz radio device
・ Near speakers , Inverter, motor and Plasma Display
3. The communication range may vary due to environment and conditions.
Manual No.TDR-MNL-L4D01-24-EN-090
TAKAYA RFID TR3 Series
Contents
Product Overview ...................................................................................................... 1
1.1
Names of Parts and Functions ..................................................................................... 2
2.1
2.2
Features .............................................................................................................................................. 1
TR3-L4D01-24 .................................................................................................................................... 2
Antenna .............................................................................................................................................. 4
Setting and connection ................................................................................................ 8
3.1
Setting ................................................................................................................................................. 8
3.1.1 DeskTop ........................................................................................................................................... 8
3.1.2 Wall Mounting .................................................................................................................................. 8
3.2
Antenna installation into a host device ................................................................................................. 9
3.2.1 Installation example by Screw holes ................................................................................................... 9
3.3
Connection ......................................................................................................................................... 11
3.3.1 Attaching the Cable and Antenna ....................................................................................................... 11
3.3.2 Direct connection to the Host Device Interface. .................................................................................. 11
Specifications ........................................................................................................... 12
4.1
TR3-L4D01-24 .................................................................................................................................. 12
4.2
Antenna ............................................................................................................................................ 16
4.2.1 TR3-CA033 .................................................................................................................................... 16
4.2.2 TR3-CA034 .................................................................................................................................... 18
4.2.3 TR3-CA044 .................................................................................................................................... 20
4.2.4 TR3-CA045 .................................................................................................................................... 22
4.3
Coupler Cable ................................................................................................................................... 24
4.4
Antenna Cable................................................................................................................................... 25
4.4.1 WIR42696 ...................................................................................................................................... 25
4.4.2 WIR42763 ...................................................................................................................................... 25
4.4.3 09019M16 ...................................................................................................................................... 26
Accessories .............................................................................................................. 27
5.1
5.2
AC Adapter(TR3-PWR-19V-2) .......................................................................................................... 27
RS232C Cross-cable(CB-232C-3) ...................................................................................................... 28
Maintenance ............................................................................................................ 29
Revision History ............................................................................................................. 30
Manual No.TDR-MNL-L4D01-24-EN-090
TAKAYA RFID TR3 Series
1
Product Overview
1.1 Features
1 Product Overview
1.1 Features
This product uses the 13.56MHz frequency. This product is the electromagnetic induction type non-contact
IC can read and write RFID tag data.
This Product is designed to be embedded and integrated within OEM devices and finished products such as label
printers, cashless payment terminals or any other device that can benefit from integrated RFID capabilities.
Host Device Interface
RS-232C
LED/BUZZER
Interface Module
UART(CMOS Level)
CPU
Communications
RF-ASIC
Antenna
Multiplexer
Tags
Antenna
Antenna
TR3-L201W4(READER/WRITER)
Module)
TR3-L4D01-24
Block Diagram
■ Conform to international standards
ISO/IEC15693 and ISO/IEC18000-3(Mode1) is supports.
■ Software
 TR3-series common communication protocol
 Software Development Kit
■ Multiplexer
Select the RF output.
■ Useful
 Continuous inventory mode
UID of the tag automatically sends Host Device.
 RDLoop mode
UID or User Data of the tag automatically sends Host Device.
For more information please refer to the TR3-PROTOCOL manual.
■ Environmentally
EU RoHS(2002/95/EC) Support
Manual No.TDR-MNL-L4D01-24-EN-100
TAKAYA RFID TR3 Series
2
Names of Parts and Functions
2.1 TR3-L4D01-24
2 Names of Parts and Functions
2.1 TR3-L4D01-24
③
⑨
①
②
④
⑤ ⑥
⑦
⑨
Manual No.TDR-MNL-L4D01-24-EN-100
TAKAYA RFID TR3 Series
2
No
①
②
③
Name
LED
Nameplate
RFID sticker
ANT1 to ANT24
④
⑤
⑥
⑦
Power Button
DC Jack
Connector
FCC ID sticker
Names of Parts and Functions
2.1 TR3-L4D01-24
Description
Displays the status of this product.
Production numbers.
Specify that the RFID radio waves are radiated.
Connect the Antenna cable.
Please connect from ANT1.
Power ON/OFF.
DC +19V input.
Connect the RS-232C cable.
Production numbers, will be 8-digit serial number.
Model Name
Serial number:********
⑧
⑨
TÜV mark
Screw holes
TÜV certification mark
6.5mm×13mm mounting holes.
Manual No.TDR-MNL-L4D01-24-EN-100
TAKAYA RFID TR3 Series
2
Names of Parts and Functions
2.2 Antenna
2.2 Antenna
2.2.1 TR3-CA033
CA033 is combined by 2 loop sub antennas and a coupler board.
④
Sub Antenna 1
TR3-CA033-1
Sub Antenna 2
TR3-CA033-2
Coupler Board
09019P04
①
②
⑤
⑤
①
①
②
②
⑥
⑥
⑥
③
⑤
①
No
①
②
③
④
⑤
Name
Screw holes
CN (PH)
CN (SMA)
ferrite sheet
Nameplate
Description
M3 holes.
Connect the coupler board.
Connect the antenna cable.
Paste on TR3-CA033-1 reverse side.
Production numbers, will be 8-digit serial number.
Model Name
Serial number:********
⑥
Inspection mark
Manual No.TDR-MNL-L4D01-24-EN-100
TAKAYA RFID TR3 Series
2
Names of Parts and Functions
2.2 Antenna
2.2.2 TR3-CA034
TR3-CA034 is combined by loop antenna and a coupler board.
Antenna
TR3-CA034
Coupler board
09019P05
①
②
⑥
①
⑤
①
④
⑥
Antenna
TR3-CA034
③
⑤
②
①
Reverse side
No
①
②
③
④
⑤
Name
Screw holes
CN (PH)
CN (SMA)
ferrite sheet
Nameplate
Description
M3 holes.
Connect the coupler board.
Connect the antenna cable.
Paste on TR3-CA034 surface side.
Production numbers, will be 8-digit serial number.
Model Name
Serial number:********
⑥
Inspection mark
Manual No.TDR-MNL-L4D01-24-EN-100
TAKAYA RFID TR3 Series
2
Names of Parts and Functions
2.2 Antenna
2.2.3 TR3-CA044
TR3-CA044 is combined by loop antenna and a coupler board.
Antenna
TR3-CA044
Coupler board
09019P16
①
②
①
①
②
⑤
Antenna
TR3-CA044
④
③
⑤
④
①
Reverse side
No
①
②
③
④
Name
Screw holes
CN (PH)
CN (SMA)
Nameplate
Description
M3 holes.
Connect the coupler board.
Connect the antenna cable.
Production numbers, will be 8-digit serial number.
Model Name
Serial number:********
⑤
Inspection mark
Manual No.TDR-MNL-L4D01-24-EN-100
TAKAYA RFID TR3 Series
2
Names of Parts and Functions
2.2 Antenna
2.2.4 TR3-CA045
TR3-CA045 is combined by loop antenna and a coupler board.
Antenna
TR3-CA045
Coupler board
09019P14
①
②
①
②
①
⑤
⑤
④
Antenna
TR3-CA045
③
④
①
Reverse side
No
①
②
③
④
Name
Screw holes
CN (PH)
CN (SMA)
Nameplate
Description
M3 holes.
Connect the coupler board.
Connect the antenna cable.
Production numbers, will be 8-digit serial number.
Model Name
Serial number:********
⑤
Inspection mark
Manual No.TDR-MNL-L4D01-24-EN-100
TAKAYA RFID TR3 Series
3
Setting and connection
3.1 Setting
3 Setting and connection
This RFID Reader/Writer product is to be professionally installed by authorized,
qualified and service-trained installation personnel only.
3.1 Setting
3.1.1
DeskTop
Don’t drop the product. . Injury may result if the product falls or is dropped.
3.1.2
Wall Mounting
Must be fastened securely the product with the screws.
Don’t install to the high place. Injury may result if the product falls or is dropped.
Screw
Manual No.TDR-MNL-L4D01-24-EN-100
TAKAYA RFID TR3 Series
3.2
3 Setting and connection
Antenna installation into a host device
3.2 Antenna installation into a host device
Incorporate the antenna in enclosure by all means.
3.2.1
Installation example by Screw holes
・TR3-CA033
M3 Screw
M3 Screw
・TR3-CA034
Manual No.TDR-MNL-L4D01-24-EN-100
TAKAYA RFID TR3 Series
3.2
3 Setting and connection
Antenna installation into a host device
・TR3-CA044
M3 Screw
M3 Screw
・TR3-CA045
Manual No.TDR-MNL-L4D01-24-EN-100
10
TAKAYA RFID TR3 Series
3
Setting and connection
3.3 Connection
3.3 Connection
This product will connect with the antenna and antenna cables.
This product connects with Host Device with the cable.
Type of ferrite core and number of turns are specified by compliance for FCC.
When providing this product, ferrite cores are already installed in cables.
Don’t change the type of ferrite core and number of turns of the cables (Power supply cable, RS-232C
cable, Antenna cables).
Don’t connect the combination of other than indicated in the table below.
3.3.1
Attaching the Cable and Antenna
Host Device
TR3-L4D01-24
Antenna
Antenna Cable
Antenna
TR3-CA033
WIR42696 and ferrite core
TR3-CA034
WIR42696 and ferrite core
TR3-CA044
WIR42763 and ferrite core
TR3-CA045
WIR42763 and ferrite core
3.3.2
Antenna Cable
09019M16
(Ferrite core around the wire.)
09019M16
(Ferrite core around the wire.)
09019M16
(Ferrite core around the wire.)
09019M16
(Ferrite core around the wire.)
Direct connection to the Host Device Interface.
TR3-L4D01-24
Host Device
Host Device
Interface
Interface harness
Manual No.TDR-MNL-L4D01-24-EN-100
11
TAKAYA RFID TR3 Series
4 Specifications
4.1 TR3-L4D01-24
4 Specifications
4.1 TR3-L4D01-24
Specifications
Item
Applicable
Japan Radio Law
Standards
FCC
Radio
Frequency
Parameter
ARIB STD-T82
FCC Part 15 Subpart B,C
FCC ID : MK4TR3-L4D01-24
RoHS
EU RoHS(2002/95/EC) Supports
Safety standard
EN60950-1(TÜV)
Carrier frequency
13.56MHz ±50ppm(Ta=25℃) or less
Transmit power or 4W ± 10%(Ta=25℃, VCC=19V)
power range
Standards
ISO/IEC 15693、ISO/IEC18000-3(Mode1)
Tags
Tag-it HF-I, my-d, I・CODE SLI
Data rate
・ISO/IEC 15693,ISO/IEC18000-3(Mode1)
Speed
Data rate
1/4
26.48kbps
Product⇒Tag
1/256
1.65kbps
26.69kbps
Tag⇒Product
Modulation
・ISO/IEC 15693,ISO/IEC18000-3(Mode1)
Parameter
ASK 10%
Product⇒Tag
FSK
Tag⇒Product
※1:Tag-it HF-I is a registered trademark of Texas Instruments Incorporated.
my-d is a registered trademark of Infineon Technologies AG.
I・CODE SLI is a registered trademark of NXP Semiconductors.
Manual No.TDR-MNL-L4D01-24-EN-100
12
TAKAYA RFID TR3 Series
4 Specifications
4.1 TR3-L4D01-24
Specifications
Item
Anti-collision
Parameter
Standards
ISO/IEC 15693
ISO/ISC 18000-3
(Mode1)
Host Interface
RS-232C
Item
Speed
Parameter
9600bps
19200bps
38400bps(※2)
None
None
Data bits
Parity
Stop bit
Flow control
Control
LED
BUZZER
Antenna
Connector
Anti-collision
YES
1 LED (green)
1 BUZZER
Connector
SMB(J)×24
Symbol
RF
GND
Center Contact
Shell
Connector
RS-232C
Connector
D-SUB 9Pin
Pin assignment
Pin No.
DC JACK
Function
RF output
GND
Symbol
NC
Rx
Tx
NC
GND
NC
NC
NC
NC
Function
Not Connected
Received data signal
Transmitted data signal
Not Connected
GND
Not Connected
Not Connected
Not Connected
Not Connected
Connector
9.5×external diameterφ5.5 internal diameterφ2.1
Pin assignment
Center electrode
External electrode
Symbol
GND
VCC
Function
GND
Power Input
※2:initialization
Manual No.TDR-MNL-L4D01-24-EN-100
13
TAKAYA RFID TR3 Series
4 Specifications
4.1 TR3-L4D01-24
Specifications
Item
Mechanical
Dimensions
data
(W x D x H)
Weight
Electrical
Power
data
Ambient
Conditions
Accessories
Temperature
Operating range
Humidity Operating
range
Temperature
Storage range
Humidity
Storage range
AC Adaptor
RS232C
Cross-cable
Manual No.TDR-MNL-L4D01-24-EN-100
Parameter
260 x 336 x 88.6mm
(Protrusions except)
approx. 4.5kg
Supply Voltage
Current consumption
Carrier off
Consumption
0 to 40 degree
:DC+19V±10%
:approx. 1.2mA
:approx. 520mA
:max 24W
30 to 80%RH
0 to 55 degree
30 to 80%RH
TR3-PWR-19V-2
CB-232C-3
14
TAKAYA RFID TR3 Series
4 Specifications
4.1 TR3-L4D01-24
■ Dimensions
Unit:mm
Tolerance:±1.0mm
( )is Recommended Dimension
Manual No.TDR-MNL-L4D01-24-EN-100
15
TAKAYA RFID TR3 Series
4
Specifications
4.2 Antenna
4.2 Antenna
4.2.1
TR3-CA033
■ Specifications
Specifications
Item
Applicable
RoHS
Standards
Antenna
Resonant
frequency
Antenna Type
Connector
CN1
Parameter
EU RoHS(2002/95/EC) Support
13.56MHz(Ta=25℃)
LOOP ANTENNA
Connector : SMA(J)
Pin assignment
Center Contact
Shell
Mechanical
data
Dimensions
(W x D x H)
Weight
Ambient
Conditions
Other
Temperature
Operating range
Humidity Operating
range
Temperature
Storage range
Humidity
Storage range
Accessories
Symbol
RF
GND
Function
RF input
GND
TR3-CA033-1:64 (W)×80(D)×7.7(H)mm
TR3-CA033-2:64 (W)×80(D)×7.1(H)mm
09019P04:55 (W)×80(D)×15.6(H)mm
TR3-CA033-1:25g
TR3-CA033-2:17g
09019P04:47g
0 to 40 degree
30 to 80%RH
0 to 55 degree
30 to 80%RH
Two Twisted pare cables
Model Name : TR3-AC-1A-120
①1.5D-2V SMA(P)-SMB(J) + Ferrite core
Model Name : WIR42696 + ZCAT13250530A(1 turn)
②1.5D-2V SMB(P)-SMB(P) + Ferrite core
Model Name : 09019M16 ( E04SR0200935A (3 turn))
②
①
Manual No.TDR-MNL-L4D01-24-EN-100
16
TAKAYA RFID TR3 Series
4
Specifications
4.2 Antenna
■ Dimensions
○TR3-CA033-1
Unit:mm
Tolerance:±1mm
Substrate thickness : 1.6mm
○TR3-CA033-2
Unit:mm
Tolerance:±1mm
Substrate thickness : 1.6mm
○09019P04
Unit:mm
Tolerance:±1mm
Substrate thickness : 1.6mm
Manual No.TDR-MNL-L4D01-24-EN-100
17
TAKAYA RFID TR3 Series
4
4.2.2
TR3-CA034
■ Specifications
Specifications
Item
Applicable
RoHS
Standards
Antenna
Resonant
frequency
Antenna Type
Connector
CN1
Specifications
4.2 Antenna
Parameter
EU RoHS(2002/95/EC) Support
13.56MHz(Ta=25℃)
LOOP ANTENNA
Connector : SMA(J)
Pin assignment
Center Contact
Shell
Mechanical
data
Dimensions
(W x D x H)
Weight
Ambient
Conditions
Temperature
Operating range
Humidity Operating
range
Temperature
Storage range
Humidity
Storage range
Accessories
Other
Symbol
RF
GND
Function
RF input
GND
TR3-CA034:238 (W)×68(D)×7.7(H)mm
09019P05:55 (W)×80(D)×15.6(H)mm
TR3-CA034:65g
09019P05:47g
0 to 40 degree
30 to 80%RH
0 to 55 degree
30 to 80%RH
Two Twisted pare cables
Model Name : TR3-AC-1A-120
①1.5D-2V SMA(P)-SMB(J) + Ferrite core
Model Name : WIR42696 + ZCAT13250530A(1 turn)
②1.5D-2V SMB(P)-SMB(P) + Ferrite core
Model Name : 09019M16 ( E04SR0200935A (3 turn))
②
①
Manual No.TDR-MNL-L4D01-24-EN-100
18
TAKAYA RFID TR3 Series
4
Specifications
4.2 Antenna
■ Dimensions
○TR3-CA034
Unit:mm
Tolerance:±1mm
Substrate thickness : 1.6mm
○09019P05
Unit:mm
Tolerance:±1mm
Substrate thickness : 1.6mm
Manual No.TDR-MNL-L4D01-24-EN-100
19
TAKAYA RFID TR3 Series
4
4.2.3
TR3-CA044
■ Specifications
Specifications
Item
Applicable
RoHS
Standards
Antenna
Resonant
frequency
Antenna Type
Connector
CN1
Specifications
4.2 Antenna
Parameter
EU RoHS(2002/95/EC) Support
13.56MHz(Ta=25℃)
LOOP ANTENNA
Connector : SMA(J)
Pin assignment
Center Contact
Shell
Mechanical
data
Dimensions
(W x D x H)
Weight
Ambient
Conditions
Temperature
Operating range
Humidity Operating
range
Temperature
Storage range
Humidity
Storage range
Accessories
Other
Symbol
RF
GND
Function
RF input
GND
TR3-CA044:433.2 (W)×91.1(D)×7.1(H)mm
09019P16:55 (W)×80(D)×15.6(H)mm
TR3-CA044:96g
09019P16:47g
0 to 40 degree
30 to 80%RH
0 to 55 degree
30 to 80%RH
Twisted pare cables
Model Name : TR3-AC-1A-090
①1.5D-2V SMA(P)-SMB(J) + Ferrite core
Model Name : WIR42763 + E04SR241336A(3 turn)
②1.5D-2V SMB(P)-SMB(P) + Ferrite core
Model Name : 09019M16 ( E04SR0200935A (3 turn))
②
①
Manual No.TDR-MNL-L4D01-24-EN-100
20
TAKAYA RFID TR3 Series
4
Specifications
4.2 Antenna
■ Dimensions
○TR3-CA044
433.23
11-Φ3.2
91.11
200
4-R5
5.5
(7.1)
Unit:mm
Tolerance:±1mm
Substrate thickness : 1.6mm
○09019P16
Unit:mm
Tolerance:±1mm
Substrate thickness : 1.6mm
Manual No.TDR-MNL-L4D01-24-EN-100
21
TAKAYA RFID TR3 Series
4
4.2.4
TR3-CA045
■ Specifications
Specifications
Item
Applicable
RoHS
Standards
Antenna
Resonant
frequency
Antenna Type
Connector
CN1
Specifications
4.2 Antenna
Parameter
EU RoHS(2002/95/EC) Support
13.56MHz(Ta=25℃)
LOOP ANTENNA
Connector : SMA(J)
Pin assignment
Center Contact
Shell
Mechanical
data
Dimensions
(W x D x H)
Weight
Ambient
Conditions
Temperature
Operating range
Humidity Operating
range
Temperature
Storage range
Humidity
Storage range
Accessories
Other
Symbol
RF
GND
Function
RF input
GND
TR3-CA045:424 (W)×84(D)×8.2(H)mm
09019P14:55 (W)×80(D)×15.6(H)mm
TR3-CA045:108g
09019P14:47g
0 to 40 degree
30 to 80%RH
0 to 55 degree
30 to 80%RH
Twisted pare cables
Model Name : TR3-AC-1A-090
①1.5D-2V SMA(P)-SMB(J) + Ferrite core
Model Name : WIR42763 + E04SR200935A(2 turn)
②1.5D-2V SMB(P)-SMB(P) + Ferrite core
Model Name : 09019M16 ( E04SR0200935A (3 turn))
②
①
Manual No.TDR-MNL-L4D01-24-EN-100
22
TAKAYA RFID TR3 Series
4
Specifications
4.2 Antenna
■ Dimensions
○TR3-CA045
424
4-R3
84
6.6
(8.2)
Unit:mm
Tolerance:±1mm
Substrate thickness : 1.6mm
○09019P14
Unit:mm
Tolerance:±1mm
Substrate thickness : 1.6 mm
Manual No.TDR-MNL-L4D01-24-EN-100
23
TAKAYA RFID TR3 Series
4 Specifications
4.3 Coupler Cable
4.3 Coupler Cable
Coupler Cable (between Antenna to coupler board)
TR3-AC-1A-***
Enter the cable length
90mm : 090
120mm : 120
■ Specifications
item
RoHS
Linetype
Connector
Cable loss
Parameter
EU RoHS(2002/95/EC) Support
AWG26
PH-PH
90mm : approx. 0.061dB
120mm : approx. 0.081dB
■ Dimensions
(Cable Length)
( )is Recommended Dimension
Manual No.TDR-MNL-L4D01-24-EN-100
24
TAKAYA RFID TR3 Series
4 Specifications
4.4 Antenna Cable
4.4 Antenna Cable
4.4.1
WIR42696
■ Specifications
item
RoHS
Linetype
Connector
Cable loss
Parameter
EU RoHS(2002/95/EC) Support
Coaxial cable 1.5D-2V
SMA(P)-SMB(J)
approx. 0.043dB
■ Dimensions
500
Unit:mm
4.4.2
WIR42763
■ Specifications
Item
RoHS
Linetype
Connector
Cable loss
Parameter
EU RoHS(2002/95/EC) Support
Coaxial cable 1.5D-2V
SMA(P)-SMB(J)
approx. 0.051dB
■ Dimensions
600
Unit:mm
Manual No.TDR-MNL-L4D01-24-EN-100
25
TAKAYA RFID TR3 Series
4 Specifications
4.4 Antenna Cable
4.4.3
09019M16
■ Specifications
Item
RoHS
Linetype
Connector
Cable loss
Ferrite core
Parameter
EU RoHS(2002/95/EC) Support
Coaxial cable 1.5D-2V
SMB(P)-SMB(P)
approx. 0.16dB
E04SR0200935A(3 turn)
■ Dimensions
WIR42696 or
WIR42763 Side
TR3-L4D01-24 Side
(1730)
Unit:mm
( )is Recommended Dimension
Manual No.TDR-MNL-L4D01-24-EN-100
26
TAKAYA RFID TR3 Series
5.1
5 Accessories
AC Adapter(TR3-PWR-19V-2)
5 Accessories
5.1 AC Adapter(TR3-PWR-19V-2)
■ Specifications
Specifications
Item
Applicable
EMI
Standards
COMPLY SAFETY
STANDARDS
RoHS
AC INPUT
VOLTAGE
FREQUENCY
DC OUTPUT
DC OUTPUT
VOLTAGE RANGE
LOAD CURRENT
OUTPUT
PLUG TYPE
Mechanical
data
Wight
Dimensions
Cable length
Ambient
Conditions
Temperature
Operating range
Humidity Operating
range
Temperature
Storage range
Humidity
Storage range
Ferrite core
Parameter
FCC class B, CISPR 22 class B
UL60950, IEC60950, CSA22.2 No.60950,
LPS:Limited Power Source, PSE
EU RoHS(2002/95/EC) Support
AC100V to AC240V
50 to 60Hz
DC19.0V±5%
3.15A
CENTER MINUS
9.5×external diameterφ5.5
internal diameterφ2.1
approx. 500g
53(W) x 118.4(D) x 33.5(H)mm
(Cords are not included)
DC Plug side:approx. 1170mm
AC Plug side:approx. 1700mm
0 to 40 degree
10 to 85%RH
-25 to 60 degree
10 to 95%RH
MSFC 13K(4 turn) 2pcs
■ Dimension
Ferrite Core
Unit:mm
)is Recommended Dimension
Manual No.TDR-MNL-L4D01-24-EN-100
27
TAKAYA RFID TR3 Series
5.2
5 Accessories
RS232C Cross-cable(CB-232C-3)
5.2 RS232C Cross-cable(CB-232C-3)
Type of ferrite core and number of turns are specified by compliance for FCC.
Don’t change and remove the ferrite core.
Don’t uses except the bundled RS232C Cross-cable.
■ Specifications
Specifications
RoHS
Connector
screw
Cable length
Ferrite core
Connection
Parameter
EU RoHS(2002/95/EC) Support
D-sub 9Pin
Inch screw
approx. 4.5m
ZCAT17300730A(1 turn)
Cross-cable
■ Dimension
(4500)
Host Device ( ex.PC ) Side
TR3-L4D01-24 Side
Unit:mm
)is Recommended Dimension
Manual No.TDR-MNL-L4D01-24-EN-100
28
TAKAYA RFID TR3 Series
6 Maintenance
This product is mainly used in electronic components and semiconductors.
Therefore, the long-term stable operation, the environment and conditions are expected to defect, as
shown below.
• Device degradation due to overvoltage and overcurrent.
• Device degradation due to high temperature and long-term stress.
• Poor contact of the connector and cause deterioration of insulation by moisture
or dust.
• Connector corrosion by corrosive gases.
In order to use this product at its best, please conduct routine or periodic inspections.
Item
Maintenance
Criteria
Temperature
Temperature Operating range 0 to 40 degree
Humidity
Humidity Operating range
30 to 80%RH
Ambient
Enclosure
conditions
Check the dusty
None
rating
Corrosive
Check the corrosion
None
Input
Check the voltage
Power
Input Voltage : DC19V±10%
Voltage
Check the Voltage fluctuation
fluctuation
Check the Screw
Product
Checking and verifying
Attachment
Check the Connector
Cable
Check the Cable break
None
Performance
Check the Performance
Work
Manual No.TDR-MNL-L4D01-24-EN-100
29
TAKAYA RFID TR3 Series
Revision History
Revision code
1.00
Date
2015/05/08
Revised contents
Original production
Manual No.TDR-MNL-L4D01-24-EN-100
30
TAKAYA RFID TR3 Series
[URL]
[Mail]
http://www.takaya.co.jp/
rfid@takaya.co.jp
31

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 37
Language                        : ja-JP
Tagged PDF                      : Yes
Author                          : RF事業推進部 嶋津
Creator                         : Microsoft® Word 2010
Create Date                     : 2015:05:08 20:11:43+09:00
Modify Date                     : 2015:05:08 20:11:43+09:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MK4TR3-L4D01-24

Navigation menu