THALES DIS AlS Deutschland ELS31-US LTE Module User Manual hid elsx1 us
Gemalto M2M GmbH LTE Module hid elsx1 us
User Manual
Cinterion® ELS31-US/ELS51-US Hardware Interface Overview Version: DocId: 01.000a ELS31-US_ELS51-US_HIO_v01.000a M2M.GEMALTO.COM Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 2 of 46 Document Name: Cinterion® ELS31-/ELS51-US Hardware Interface Overview Version: 01.000a Date: 2016-12-28 DocId: ELS31-US_ELS51-US_HIO_v01.000a Status: Confidential / Preliminary GENERAL NOTE THE USE OF THE PRODUCT INCLUDING THE SOFTWARE AND DOCUMENTATION (THE "PRODUCT") IS SUBJECT TO THE RELEASE NOTE PROVIDED TOGETHER WITH PRODUCT. IN ANY EVENT THE PROVISIONS OF THE RELEASE NOTE SHALL PREVAIL. THIS DOCUMENT CONTAINS INFORMATION ON GEMALTO M2M PRODUCTS. THE SPECIFICATIONS IN THIS DOCUMENT ARE SUBJECT TO CHANGE AT GEMALTO M2M'S DISCRETION. GEMALTO M2M GMBH GRANTS A NONEXCLUSIVE RIGHT TO USE THE PRODUCT. THE RECIPIENT SHALL NOT TRANSFER, COPY, MODIFY, TRANSLATE, REVERSE ENGINEER, CREATE DERIVATIVE WORKS; DISASSEMBLE OR DECOMPILE THE PRODUCT OR OTHERWISE USE THE PRODUCT EXCEPT AS SPECIFICALLY AUTHORIZED. THE PRODUCT AND THIS DOCUMENT ARE PROVIDED ON AN "AS IS" BASIS ONLY AND MAY CONTAIN DEFICIENCIES OR INADEQUACIES. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, GEMALTO M2M GMBH DISCLAIMS ALL WARRANTIES AND LIABILITIES. THE RECIPIENT UNDERTAKES FOR AN UNLIMITED PERIOD OF TIME TO OBSERVE SECRECY REGARDING ANY INFORMATION AND DATA PROVIDED TO HIM IN THE CONTEXT OF THE DELIVERY OF THE PRODUCT. THIS GENERAL NOTE SHALL BE GOVERNED AND CONSTRUED ACCORDING TO GERMAN LAW. Copyright Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved. Copyright © 2016, Gemalto M2M GmbH, a Gemalto Company Trademark Notice Gemalto, the Gemalto logo, are trademarks and service marks of Gemalto and are registered in certain countries. Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. All other registered trademarks or trademarks mentioned in this document are property of their respective owners. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 3 of 46 Contents 46 Contents Introduction ................................................................................................................. 7 1.1 Key Features at a Glance .................................................................................. 7 1.2 ELS31-US/ELS51-US System Overview ......................................................... 10 Interface Characteristics .......................................................................................... 11 2.1 Application Interface ........................................................................................ 11 2.1.1 USB Interface...................................................................................... 11 2.1.2 Serial Interface ASC0 ......................................................................... 12 2.1.3 Serial Interface ASC1 ......................................................................... 13 2.1.4 UICC/SIM/USIM Interface................................................................... 14 2.1.5 GPIO Interface .................................................................................... 16 2.1.6 I2C Interface ........................................................................................ 17 2.1.7 SPI Interface ....................................................................................... 17 2.1.8 Pulse Counter ..................................................................................... 17 2.1.9 HSIC Interface (ELS51-US Only)........................................................ 17 2.1.10 SDIO Interface (ELS51-US Only) ....................................................... 18 2.1.11 Control Signals.................................................................................... 19 2.1.11.1 Status LED .......................................................................... 19 2.1.11.2 Fast Shutdown .................................................................... 19 2.2 RF Antenna Interface....................................................................................... 20 2.2.1 Antenna Installation ............................................................................ 21 2.2.2 RF Line Routing Design...................................................................... 22 2.2.2.1 RF Interface Signals Circuit Diagram Example ................... 22 2.2.2.2 Line Arrangement Examples ............................................... 23 2.3 Sample Application .......................................................................................... 28 Operating Characteristics ........................................................................................ 30 3.1 Operating Modes ............................................................................................. 30 3.2 Power Supply................................................................................................... 30 Mechanical Dimensions, Mounting and Packaging............................................... 31 4.1 Mechanical Dimensions of ELS31-US/ELS51-US ........................................... 31 Regulatory and Type Approval Information ........................................................... 33 5.1 Directives and Standards................................................................................. 33 5.2 SAR requirements specific to portable mobiles ............................................... 35 5.3 Reference Equipment for Type Approval ......................................................... 36 5.4 Compliance with FCC and IC Rules and Regulations ..................................... 37 ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 4 of 46 Contents 46 Document Information.............................................................................................. 39 6.1 Revision History ............................................................................................... 39 6.2 Related Documents ......................................................................................... 39 6.3 Terms and Abbreviations ................................................................................. 39 6.4 Safety Precaution Notes .................................................................................. 43 Appendix.................................................................................................................... 44 7.1 List of Parts and Accessories........................................................................... 44 ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 5 of 46 Tables 46 Tables Table 1: Table 2: Table 3: Table 4: Table 5: Table 6: Table 7: Table 8: Table 9: Table 10: Table 11: Table 12: Table 13: Table 14: Table 15: Signals of the SIM interface (SMT application interface) ............................... GPIO lines and possible alternative assignment............................................ SDIO interface features.................................................................................. SDIO interface lines ....................................................................................... Return loss in the active band........................................................................ Overview of operating modes ........................................................................ Directives ....................................................................................................... Standards of North American type approval .................................................. Standards of GCF type approval.................................................................... Requirements of quality ................................................................................. Standards of the Ministry of Information Industry of the People’s Republic of China ............................................................................ Toxic or hazardous substances or elements with defined concentration limits ............................................................................................................... Antenna gain limits for FCC and IC (TBD) ..................................................... List of parts and accessories.......................................................................... Molex sales contacts (subject to change) ...................................................... ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 14 16 18 18 20 30 33 33 33 33 34 34 37 44 45 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 6 of 46 Figures 46 Figures Figure 1: Figure 2: Figure 3: Figure 4: Figure 5: Figure 6: Figure 7: Figure 8: Figure 9: Figure 10: Figure 11: Figure 12: Figure 13: Figure 14: Figure 15: Figure 16: ELS31-US/ELS51-US system overview......................................................... USB circuit ..................................................................................................... Serial interface ASC0..................................................................................... Serial interface ASC1..................................................................................... External UICC/SIM/USIM card holder circuit ................................................. RF interface signals example......................................................................... Embedded Stripline with 65µm prepreg (1080) and 710µm core .................. Micro-Stripline on 1.0mm standard FR4 2-layer PCB - example 1 ................ Micro-Stripline on 1.0mm Standard FR4 PCB - example 2............................ Micro-Stripline on 1.5mm Standard FR4 PCB - example 1............................ Micro-Stripline on 1.5mm Standard FR4 PCB - example 2............................ Schematic diagram of ELS31-US/ELS51-US sample application.................. ELS31-US/ELS51-US– top and bottom view ................................................. Dimensions of ELS31-US/ELS51-US (all dimensions in mm) ....................... Dimensions of ELS31-US/ELS51-US (all dimensions in mm) - bottom view . Reference equipment for Type Approval ....................................................... ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 10 11 12 13 15 22 23 24 25 26 27 29 31 32 32 36 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 7 of 46 1 Introduction 10 Introduction This document1 describes the hardware of the Cinterion® ELS31-US and ELS51-US modules. It helps you quickly retrieve interface specifications, electrical and mechanical details and information on the requirements to be considered for integrating further components. The ELS31-US and ELS51-US modules include a baseband, a complete dual band RF frontend, memory and required circuitry to meet 3GPP E-UTRA (Long Term Evolution - LTE, Release 10 set of specifications). The module variants differentiate a follows: - ELS31-US provides LTE connectivity with IP Services - ELS51-US adds a Linux execution environment available for customer applications 1.1 Key Features at a Glance Feature Implementation General Frequency bands LTE Triband: B2, B4, B12 Output power Class 3 (+23dBm +-2dB) for LTE 1900, LTE FDD B2 Class 3 (+23dBm +-2dB) for LTE AWS, LTE B4 Class 3 (+23dBm +-2dB) for LTE 700, LTE FDD B12 Power supply 3.3V to 4.5V Operating temperature (board temperature) Normal operation: -30°C to +80°C Extended operation: -40°C to +90°C Physical Dimensions: 27.60mm x 18.80mm x 2.05mm Weight: approx. 3g RoHS All hardware components fully compliant with EU RoHS Directive LTE features 3GPP Release 9 DL 10Mbps, UL 5Mbps LTE Cat. 1 data rates SMS Point-to-point MT and MO Text mode Storage in mobile equipment Software AT commands Hayes, 3GPP TS 27.007, TS 27.005, product specific SIM Application Toolkit SAT Release 99 Firmware update Generic update from host application over ASC0 or USB modem OTA over ASC0 and over USB 1. The document is effective only if listed in the appropriate Release Notes as part of the technical documentation delivered with your Gemalto M2M product. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 8 of 46 1.1 Key Features at a Glance 10 Feature Implementation Interfaces Module interface Surface mount device with solderable connection pads (SMT application interface). Land grid array (LGA) technology ensures high solder joint reliability and allows the use of an optional module mounting socket. For more information on how to integrate SMT modules see also [4]. This application note comprises chapters on module mounting and application layout issues as well as on SMT application development equipment. USB USB 2.0 High Speed (480Mbit/s) device interface, Full Speed (12Mbit/s) compliant 2 serial interfaces ASC0: • 8-wire modem interface with status and control lines, unbalanced, asynchronous • Default baud rate: 115,200 baud • Adjustable baud rates: 4,800 to 921,600, no autobauding support • Supports RTS0/CTS0 hardware flow control. • Indication of incoming data/SMS on RING0 (can be used to wake up host from power down modes) ASC1 (shared with GPIO lines): • 4-wire, unbalanced asynchronous interface • Default baud rate: 115,200 baud • Adjustable baud rates: 4,800bps to 921,600bps • Supports RTS1/CTS1 hardware flow control UICC interface Supported SIM/USIM cards: 3V, 1.8V Embedded UICC Module is prepared for an embedded UICC GPIO interface 20 pads of the application interface programmable as GPIO pads (17) or GPO pads (3): GP(I)Os can be configured as COUNTER, FST_SHDN, ASC0, ASC1, and SPI signal lines Programming is done via AT commands I2C interface Supports I2C serial interface SPI interface Supports SPI interface SDIO ELS51-US only: 4 wire interface. HSIC ELS51-US only: High Speed Interchip Communication interface. ADC Analog-to-Digital Converter with one unbalanced analog input. Digitial audio interface Hardware prepared for future use. Antenna interface pads 50Ω LTE main antenna, 50LTE diversity antenna ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 9 of 46 1.1 Key Features at a Glance 10 Feature Implementation Power on/off, Reset Power on/off Switch-on by hardware signal ON Switch-off by AT command Switch off by hardware signal GPIO4/FST_SHDN instead of AT command Automatic switch-off in case of critical temperature and voltage conditions Reset Orderly shutdown and reset by AT command Emergency reset by hardware signal EMERG_RST Evaluation kit Evaluation module ELS31-US/ELS51-US module soldered onto a dedicated PCB that can be connected to an adapter in order to be mounted onto the DSB75. DSB75 DSB75 Development Support Board designed to test and type approve Gemalto M2M modules and provide a sample configuration for application engineering. A special adapter is required to connect the ELS31-US/ELS51US evaluation module to the DSB75. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 10 of 46 1.2 ELS31-US/ELS51-US System Overview 10 ELS31-US/ELS51-US System Overview Application Serial modem interface I2C SPI USB HSIC SDIO ADC POWER ANTENNA (LTE dual band) ON Emergency reset ADC Power supply CONTROL SIM card (with SIM detection) SIM interface SPI SDIO HSIC USB SPI I2C ASC0 SPI Pulse counter COUNTER GP(I)Os GPIOs Serial interface ASC1 Serial modem interface ASC0 Fast shutdown FST_SHDN LED Status GPIO interface Module Antenna / div. Antenna 1.2 Figure 1: ELS31-US/ELS51-US system overview ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 11 of 46 2 Interface Characteristics 29 Interface Characteristics ELS31-US/ELS51-US is equipped with an SMT application interface that connects to the external application. The SMT application interface incorporates the various application interfaces as well as the RF antenna interfaces. 2.1 Application Interface 2.1.1 USB Interface ELS31-US/ELS51-US supports a USB 2.0 High Speed (480Mbit/s) device interface that is Full Speed (12Mbit/s) compliant. The USB interface is primarily intended for use as command and data interface and for downloading firmware. The VUSB line is used for cable detection only, this is to be supplied by the external device. The USB circuitry in the ELS31-US/ELS51-US is designed to meet the USB 2.0 specification for self-power.2.0”1. Module SMT VREG (3V075) lin. reg. BATT+ GND USB part1) VBUS Detection only VUSB_IN USB_DP2) USB_DN2) DP DN Host wakeup RING0 1) It is recommended to add EMI suppression filter (see section 2.1.3.1) If the USB interface is operated in High Speed mode (480MHz), it is recommended to take special care routing the data lines USB_DP and USB_DN. Application layout should in this case implement a differential impedance of 90Ohm for proper signal integrity. 2) Figure 2: USB circuit To properly connect the module's USB interface to the external application, a USB 2.0 compatible connector and cable or hardware design is required. Furthermore, the USB modem driver distributed with ELS31-US/ELS51-US needs to be installed. 1. The specification is ready for download on http://www.usb.org/developers/docs/ ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 12 of 46 2.1 Application Interface 29 2.1.2 Serial Interface ASC0 ELS31-US/ELS51-US offers an 8-wire unbalanced, asynchronous modem interface ASC0 conforming to ITU-T V.24 protocol DCE signalling. The electrical characteristics do not comply with ITU-T V.28. The significant levels are 0V (for low data bit or active state) and 1.8V (for high data bit or inactive state). ELS31-US/ELS51-US is designed for use as a DCE. Based on the conventions for DCE-DTE connections it communicates with the customer application (DTE) using the following signals: • Port TXD @ application sends data to the module’s TXD0 signal line • Port RXD @ application receives data from the module’s RXD0 signal line Figure 3: Serial interface ASC0 Features: • Includes the data lines TXD0 and RXD0, the status lines RTS0 and CTS0 and, in addition, the modem control lines DTR0, DSR0, DCD0 and RING0. • Configured for 8 data bits, no parity and 1 stop bit. • ASC0 can be operated at fixed bit rates from 4800bps up to 921600bps. • Supports RTS0/CTS0 hardware flow control. Communication is possible by using only RXD and TXD lines, if RTS0 is pulled low. • Wake up from SLEEP mode by RTS0 activation. The ASC0 interface is dedicated to signaling via AT commands (3GPP standard 27.007 + module specific AT commands). ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 13 of 46 2.1 Application Interface 29 2.1.3 Serial Interface ASC1 ELS31-US/ELS51-US provides a 4-wire unbalanced, asynchronous modem interface ASC1 conforming to ITU-T V.24 protocol DCE signaling. The electrical characteristics do not comply with ITU-T V.28. The significant levels are 0V (for low data bit or active state) and 1.8V (for high data bit or inactive state). The ASC1 interface lines are originally available as GPIO lines. If configured as ASC1 lines, the GPIO lines are assigned as follows: GPIO16 --> RXD1, GPIO17 --> TXD1, GPIO18 --> RTS1 and GPIO19 --> CTS1. Configuration is done by AT command (see [1]: AT^SCFG). The configuration is non-volatile and becomes active after a module restart. ELS51-US is designed for use as a DCE. Based on the conventions for DCE-DTE connections it communicates with the customer application (DTE) using the following signals: • Port TXD @ application sends data to module’s TXD1 signal line • Port RXD @ application receives data from the module’s RXD1 signal line Figure 4: Serial interface ASC1 Features • Includes only the data lines TXD1 and RXD1 plus RTS1 and CTS1 for hardware handshake. • On ASC1 no RING line is available. • Configured for 8 data bits, no parity and 1 or 2 stop bits. • ASC1 can be operated at fixed bit rates from 4800 bps to 921600 bps. • Supports RTS1/CTS1 hardware flow control. Communication is possible by using only RXD and TXD lines, if RTS1 is pulled low. • Wake up from SLEEP mode by RTS0 activation. AT commands for signaling are not supported on ASC1 interface. ASC1 is intended only for data transfer in a Linux environment. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 14 of 46 2.1 Application Interface 29 2.1.4 UICC/SIM/USIM Interface ELS31-US/ELS51-US has an integrated UICC/SIM/USIM interface compatible with the 3GPP 31.102 and ETSI 102 221. This is wired to the host interface in order to be connected to an external SIM card holder. Five pads on the SMT application interface are reserved for the SIM interface. The UICC/SIM/USIM interface supports 3V and 1.8V SIM cards. The CCIN signal serves to detect whether a tray (with SIM card) is present in the card holder. The CCIN signal must be connected to V180 for the detection to work on the module. Otherwise the SIM card can never be detected by the module. Using the CCIN signal is mandatory for compliance with the GSM 11.11 recommendation if the mechanical design of the host application allows the user to remove the SIM card during operation. To take advantage of this feature, an appropriate SIM card detect switch is required on the card holder. For example, this is true for the model supplied by Molex, which has been tested to operate with ELS31-US/ELS51-US and is part of the Gemalto M2M reference equipment submitted for type approval. See Section 7.1 for Molex ordering numbers. Table 1: Signals of the SIM interface (SMT application interface) Signal Description GND Separate ground connection for SIM card to improve EMC. CCCLK Chipcard clock CCVCC SIM supply voltage. CCIO Serial data line, input and output. CCRST Chipcard reset CCIN Input on the baseband processor for detecting a SIM card tray in the holder. If the SIM is removed during operation the SIM interface is shut down immediately to prevent destruction of the SIM. The CCIN signal is by default low and will change to high level if a SIM card is inserted. The CCIN signal is mandatory for applications that allow the user to remove the SIM card during operation. The CCIN signal is solely intended for use with a SIM card. It must not be used for any other purposes. Failure to comply with this requirement may invalidate the type approval of ELS31-US/ELS51-US. Note: No guarantee can be given, nor any liability accepted, if loss of data is encountered after removing the SIM card during operation. Also, no guarantee can be given for properly initializing any SIM card that the user inserts after having removed the SIM card during operation. In this case, the application must restart ELS31-US/ELS51-US. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 15 of 46 2.1 Application Interface 29 The figure below shows a circuit to connect an external SIM card holder. V180 CCIN CCVCC SIM 220nF 1nF CCRST CCIO CCCLK Figure 5: External UICC/SIM/USIM card holder circuit The total cable length between the SMT application interface pads on ELS31-US/ELS51-US and the pads of the external SIM card holder must not exceed 100mm in order to meet the specifications of 3GPP TS 51.010-1 and to satisfy the requirements of EMC compliance. To avoid possible cross-talk from the CCCLK signal to the CCIO signal be careful that both lines are not placed closely next to each other. A useful approach is using a GND line to shield the CCIO line from the CCCLK line. The ELS31-US/ELS51-US includes embedded ESD protection for the SIM interface that complies to ETSI EN 301 489-1/7: Contact discharge: ± 4kV, air discharge: ± 8kV. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 16 of 46 2.1 Application Interface 29 2.1.5 GPIO Interface ELS31-US/ELS51-US offers a GPIO interface with 17 GPIO and 3 GPO lines. The lines are shared with other interfaces or functions: Fast shutdown (see Section 2.1.11.2), status LED (see Section 2.1.11.1), a pulse counter (see Section 2.1.8), ASC0 (see Section 2.1.2), ASC1 (see Section 2.1.3), SPI (see Section 2.1.7), and HSIC (see Section 2.1.9). The following table shows the configuration variants for the GPIO pads. All variants are mutually exclusive, i.e. a pad configured for instance as Status LED is locked for alternative usage. Table 2: GPIO lines and possible alternative assignment GPIO Fast Shutdown Status LED Pulse Counter ASC0 GPIO1 DTR0 GPIO2 DCD0 GPIO3 DSR0 GPIO4 GPO5 ASC1 SPI HSIC FST_SHDN LED GPIO6 GPIO7 GPIO8 COUNTER GPIO16 RXD1 AP_WAKEUP GPIO17 TXD1 HOST_ACTIVE GPIO18 RTS1 CP_WAKEUP GPIO19 CTS1 SUSPEND GPIO20 GPIO21 GPIO22 GPO23 GPIO24 RING0 GPIO25 GPO26 SPI_CS1 GPIO27 SPI_CS2 After startup, the above mentioned alternative GPIO line assignments can be configured using AT commands (see [1]). The configuration is non-volatile and available after module restart. Notes: • GPO5, GPO23 and GPO26 are GPOs only. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 17 of 46 2.1 Application Interface 29 2.1.6 I2C Interface I2C is a serial, 8-bit oriented data transfer bus for bit rates up to 100kbps. It consists of two lines, the serial data line I2CDAT and the serial clock line I2CCLK. The module acts as a single master device, e.g. the clock I2CCLK is driven by the module. I2CDAT is a bi-directional line. Each device connected to the bus is software addressable by a unique 7-bit address, and simple master/slave relationships exist at all times. The module operates as master-transmitter or as master-receiver. The customer application transmits or receives data only on request of the module. The I2C interface can be powered via the V180 line of ELS31-US/ELS51-US. If connected to the V180 line, the I2C interface will properly shut down when the module enters the Power Down mode. Note: Good care should be taken when creating the PCB layout of the host application: The traces of I2CCLK and I2CDAT should be equal in length and as short as possible. 2.1.7 SPI Interface The ELS31-US/ELS51-US GPIO interface lines can be configured as Serial Peripheral Interface (SPI). The SPI is a synchronous serial interface for control and data transfer between ELS31-US/ELS51-US and the external application. Only one application can be connected to the SPI and the interface supports only master mode. The transmission rates are up to 6.5Mbit/ s. The SPI interface comprises the two data lines SPI_MOSI and SPI_MISO, the clock line SPI_CLK a well as the chip select lines SPI_CS1 and SPI_CS2. 2.1.8 Pulse Counter The GPIO8 line can be configured as pulse counter line COUNTER (for GPIOs see Section 2.1.5). The pulse counter interface can be used, for example, as a clock - it is designed to measure signals from 0 to 1000 pulses per second. Note that the pulse counter works in batches of 8 pulses, i.e., the URC indicates the number of pulses counted in batches of 8 pulses. For more information on how to use this feature see [1]. 2.1.9 HSIC Interface (ELS51-US Only) The (USB) High Speed Inter Chip (HSIC) interface can be used between the module and an external application processor, and is compliant to the High Speed USB 2.0 interface with 480Mbit/s. The maximum distance between module processor and external application processor should not exceed 100mm. The HSIC interface comprises two signal lines (strobe - HSIC_STRB - and data - HSIC_DATA) used in a source synchronous serial interface with a 240MHz clock to provide a 480Mbps USB interface. The HSIC_STRB and HSIC_DATA lines are high-speed signals and should be routed as 50Ohm impedance traces. The trace length of these signals should be balanced to minimize timing skew and be no longer than 100mm. The HSIC interface implementation complies with the USB HSIC standard “High-Speed InterChip USB Electrical Specification”, Version 1, September 23, 20071. 1. The USB specifications are ready for download on http://www.usb.org/developers/docs/usb20_docs/ ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 18 of 46 2.1 Application Interface 29 2.1.10 SDIO Interface (ELS51-US Only) The Secure Digital Input Output (SDIO) interface can be used to for instance connect an SD card. The SDIO interface has the following features: Table 3: SDIO interface features Feature Description/Value Interface Type SDIO/SD1 (1 data line), SDIO/SD4 (4 data lines), MMC4 (4 data lines) Voltage 1.8 V DMA Mode SDMA / ADMA1 / ADMA2 Number of SLOTs Implement DDR mode Yes Card inserted status Yes SDIOCLK frequency Default Mode: 23 MHz maximum High Speed Mode: 46 MHz maximum UHS-I Mode: 92 MHz Max block length 2048 bytes SDIO interrupt support Yes, support SDIO/SD1, SDIO/SD4 mode interrupts Table 4 lists the six SDIO interface lines: Table 4: SDIO interface lines Signal Direction Description SDIOCLK Out SD master clock output to SD/MMC/SDIO device. SDIOCMD I/O Command line. SDIO0 I/O SDIO1 I/O Data lines. Only SDIO0 carries data in 1-bit SD mode, SDIO0..3 carry data in 4-bits mode. SDIO interrupt is multiplexed with SDIO1. SDIO2 I/O SDIO3 I/O ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 19 of 46 2.1 Application Interface 29 2.1.11 2.1.11.1 Control Signals Status LED The LED line can also be configured as GPO5 line, and can be used to drive a status LED that indicates different operating modes of the module (for GPOs see Section 2.1.5). LED and GPO functionality are mutually exclusive. 2.1.11.2 Fast Shutdown The GPIO4 interface line can be configured as fast shutdown signal line FST_SHDN. The configured FST_SHDN line is an active low control signal. If enabled, a low impulse of 10 milliseconds on the FST_SHDN line starts the fast shutdown procedure.The fast shutdown procedure still finishes any data activities on the module‘s flash file system, thus ensuring data integrity, but the module will no longer deregister gracefully from the network. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 20 of 46 2.2 RF Antenna Interface 29 2.2 RF Antenna Interface The RF interface has an impedance of 50Ω. ELS31-US/ELS51-US is capable of sustaining a total mismatch at the antenna line without any damage, even when transmitting at maximum RF power. The external antenna must be matched properly to achieve best performance regarding radiated power, modulation accuracy and harmonic suppression. Antenna matching networks are not included on the ELS31-US/ELS51-US module and should be placed in the host application if the antenna does not have an impedance of 50Ω. Regarding the return loss ELS31-US/ELS51-US provides the following values in the active band: Table 5: Return loss in the active band State of module Return loss of module Recommended return loss of application Receive > 8dB > 12dB Transmit not applicable > 12dB ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 21 of 46 2.2 RF Antenna Interface 29 2.2.1 Antenna Installation The antenna is connected by soldering the antenna pads (RF_OUT, pad #59 and DIV_ANT, pad 56) its neighboring ground pads (GND, i.e., pads #55, #57, #58 and #60) directly to the application’s PCB. The antenna pad is the antenna reference point (ARP) for ELS31-US/ELS51US. All RF data specified throughout this document is related to the ARP. The distance between the antenna RF pads and its neighboring GND pads has been optimized for best possible impedance. On the application PCB, special attention should be paid to these 3 pads, in order to prevent mismatch. The wiring of the antenna connection line, starting from the antenna pad to the application antenna should result in a 50Ω line impedance. Line width and distance to the GND plane needs to be optimized with regard to the PCB’s layer stack. Some examples are given in Section 2.2.2. To prevent receiver desensitization due to interferences generated by fast transients like high speed clocks on the application PCB, it is recommended to realize the antenna connection line using embedded Stripline rather than Micro-Stripline technology. Please see Section 2.2.2.2 for an example. For type approval purposes, the use of a 50Ω coaxial antenna connector (U.FL-R-SMT) might be necessary. In this case the U.FL-R-SMT connector should be placed as close as possible to ELS31-US/ELS51-US‘s antenna pad. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 22 of 46 2.2 RF Antenna Interface 29 2.2.2 2.2.2.1 RF Line Routing Design RF Interface Signals Circuit Diagram Example Figure 6 is a topology reference, and it is recommended not to deviate from this circuit for your external application. The RF inter-connects called RF Port 1 and RF Port 2 are examples only. Depending on the RF antenna, the interfacing system will dictate the RF inter-connects. Figure 6: RF interface signals example Please be also aware of ESD protection required on the RF interface lines. ESD protection might be utilized through the above pi-network (primarily intended for managing any additional RF optimization needs), or by additional components in series with the pi-network illustrated above. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 23 of 46 2.2 RF Antenna Interface 29 2.2.2.2 Line Arrangement Examples Several dedicated tools are available to calculate line arrangements for specific applications and PCB materials - for example from http://www.polarinstruments.com/ (commercial software) or from http://web.awrcorp.com/Usa/Products/Optional-Products/TX-Line/ (free software). Embedded Stripline This figure below shows a line arrangement example for embedded stripline with 65µm FR4 prepreg (type: 1080) and 710µm FR4 core (4-layer PCB). Figure 7: Embedded Stripline with 65µm prepreg (1080) and 710µm core ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 24 of 46 2.2 RF Antenna Interface 29 Micro-Stripline This section gives two line arrangement examples for micro-stripline. • Micro-Stripline on 1.0mm Standard FR4 2-Layer PCB The following two figures show examples with different values for D1 (ground strip separation). Application board Ground line Antenna line Ground line Figure 8: Micro-Stripline on 1.0mm standard FR4 2-layer PCB - example 1 ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 25 of 46 2.2 RF Antenna Interface 29 Application board Ground line Antenna line Ground line Figure 9: Micro-Stripline on 1.0mm Standard FR4 PCB - example 2 ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 26 of 46 2.2 RF Antenna Interface 29 • Micro-Stripline on 1.5mm Standard FR4 2-Layer PCB The following two figures show examples with different values for D1 (ground strip separation). Application board Ground line Antenna line Ground line Figure 10: Micro-Stripline on 1.5mm Standard FR4 PCB - example 1 ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 27 of 46 2.2 RF Antenna Interface 29 Application board Ground line Antenna line Ground line Figure 11: Micro-Stripline on 1.5mm Standard FR4 PCB - example 2 ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 28 of 46 2.3 Sample Application 29 2.3 Sample Application Figure 12 shows a typical example of how to integrate a ELS31-US/ELS51-US module with an application. Usage of the various host interfaces depends on the desired features of the application. Because of the high RF field density inside the module, it cannot be guaranteed that no self interference might occur, depending on frequency and the applications grounding concept. The potential interferers may be minimized by placing small capacitors (47pF) at suspected lines (e.g. RXD0, or ON). While developing SMT applications it is strongly recommended to provide test points for certain signals, i.e., lines to and from the module - for debug and/or test purposes. The SMT application should allow for an easy access to these signals. For details on how to implement test points see [4]. The EMC measures are best practice recommendations. In fact, an adequate EMC strategy for an individual application is very much determined by the overall layout and, especially, the position of components. For example, mounting the internal acoustic transducers directly on the PCB eliminates the need to use the ferrite beads shown in the sample schematic. Note: ELS31-US/ELS51-US is not intended for use with cables longer than 3m. Disclaimer No warranty, either stated or implied, is provided on the sample schematic diagram shown in Figure 12 and the information detailed in this section. As functionality and compliance with national regulations depend to a great amount on the used electronic components and the individual application layout manufacturers are required to ensure adequate design and operating safeguards for their products using ELS31-US/ELS51-US modules. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 29 of 46 2.3 Sample Application 29 ELS31/ELS51 Main Antenna SDIO WiFi Div. Antenna HSIC USB BATT+RF ON Power Supply BATT+BB 33pF FST_SHUTDOWN 33pF + 150µF Low ESR! ASC0 µC ASC1 USB Blocking GPIOs LED COUNTER V180 2k2 V180 CCIN CCVCC CCIO CCRST CCCLK SIM 220nF 10pF 1nF 10pF 2k2 I2CCLK I2CDAT GND Interfaces available only on ELS51 Figure 12: Schematic diagram of ELS31-US/ELS51-US sample application ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 30 of 46 3 Operating Characteristics 30 Operating Characteristics 3.1 Operating Modes The table below briefly summarizes the various operating modes referred to throughout the document. Table 6: Overview of operating modes Mode Function Normal operation LTE IDLE No data transfer is in progress and the USB connection is suspended by host (or is not present) and no active communication via ASC0/ ASC1. In IDLE mode, the software can be active or in SLEEP state. LTE DATA LTE data transfer in progress. Power consumption depends on network settings and data transfer rate. Power Down Normal shutdown after sending the power down command. Software is not active. Interfaces are not accessible. Operating voltage remains applied. Airplane mode Airplane mode shuts down the radio part of the module, causes the module to log off from the LTE network and disables all AT commands whose execution requires a radio connection. Airplane mode can be controlled by AT command (see [1]). In Airplane mode, the software can be active or in SLEEP state. 3.2 Power Supply ELS31-US/ELS51-US needs to be connected to a power supply at the SMT application interface - 2 BATT lines and GND. There are two separate voltage domains for BATT: • BATT_BB with a line mainly for the baseband power supply. • BATT_RF with a line for the RF power amplifier supply. Please note that throughout the document BATT refers to both voltage domains and power supply lines - BATT_BB and BATT_RF. The power supply of ELS31-US/ELS51-US has to be a single voltage source at BATT_BB and BATT_RF. It must be able to provide the current for all operation modes of the module. All the key functions for supplying power to the device are handled by the power management section of the analog controller. This IC provides the following features: • • • Stabilizes the supply voltages for the baseband using low drop linear voltage regulators and a DC-DC step down switching regulator. Switches the module's power voltages for the power-up and -down procedures. SIM switch to provide SIM power supply. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 31 of 46 4 Mechanical Dimensions, Mounting and Packaging 32 Mechanical Dimensions, Mounting and Packaging The following sections describe the mechanical dimensions of ELS31-US/ELS51-US and give recommendations for integrating ELS31-US/ELS51-US into the host application. 4.1 Mechanical Dimensions of ELS31-US/ELS51-US Figure 13 shows the top and bottom view of ELS31-US/ELS51-US and provides an overview of the board's mechanical dimensions. For further details see Figure 14. Product label Top view Bottom view Figure 13: ELS31-US/ELS51-US– top and bottom view ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 32 of 46 4.1 Mechanical Dimensions of ELS31-US/ELS51-US 32 0.1 0.1(TOTAL) 0.31 0.04(PCB) 27.6 0.1 18.8 2.05 TOP VIEW Figure 14: Dimensions of ELS31-US/ELS51-US (all dimensions in mm) 18.8 1.64 0.16 2.6 1.45 0.4 1.2 0.8 0.4 1.05 27.6 0.9 1.1 1.1 0.15 1.05 0.4 0.55 0.55 #0550.7*&8 Figure 15: Dimensions of ELS31-US/ELS51-US (all dimensions in mm) - bottom view ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 33 of 46 5 Regulatory and Type Approval Information 38 Regulatory and Type Approval Information 5.1 Directives and Standards ELS31-US/ELS51-US is designed to comply with the directives and standards listed below. It is the responsibility of the application manufacturer to ensure compliance of the final product with all provisions of the applicable directives and standards as well as with the technical specifications provided in the "ELS31-US/ELS51-US Hardware Interface Description". Table 7: Directives 2002/95/EC (RoHS 1) 2011/65/EC (RoHS 2) Directive of the European Parliament and of the Council of 27 January 2003 (and revised on 8 June 2011) on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) Table 8: Standards of North American type approval CFR Title 47 Code of Federal Regulations, Part 22 and Part 24 (Telecommunications, PCS); US Equipment Authorization FCC OET Bulletin 65 (Edition 97-01) Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields UL 60 950-1 Product Safety Certification (Safety requirements) California Leadfree Mandate Covered by European RoHS requirements RSS132 (Issue2) RSS133 (Issue5) Canadian Standard Table 9: Standards of GCF type approval 3GPP TS 51.010-1 Digital cellular telecommunications system (Release 10); Mobile Station (MS) conformance specification; GCF-CC V3.58 Global Certification Forum - Certification Criteria Table 10: Requirements of quality IEC 60068 Environmental testing DIN EN 60529 IP codes ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 34 of 46 5.1 Directives and Standards 38 Table 11: Standards of the Ministry of Information Industry of the People’s Republic of China SJ/T 11363-2006 “Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products” (2006-06). SJ/T 11364-2006 “Marking for Control of Pollution Caused by Electronic Information Products” (2006-06). According to the “Chinese Administration on the Control of Pollution caused by Electronic Information Products” (ACPEIP) the EPUP, i.e., Environmental Protection Use Period, of this product is 20 years as per the symbol shown here, unless otherwise marked. The EPUP is valid only as long as the product is operated within the operating limits described in the Gemalto M2M Hardware Interface Description. Please see Table 12 for an overview of toxic or hazardous substances or elements that might be contained in product parts in concentrations above the limits defined by SJ/T 11363-2006. Table 12: Toxic or hazardous substances or elements with defined concentration limits ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 35 of 46 5.2 SAR requirements specific to portable mobiles 38 5.2 SAR requirements specific to portable mobiles Mobile phones, PDAs or other portable transmitters and receivers incorporating a GSM module must be in accordance with the guidelines for human exposure to radio frequency energy. This requires the Specific Absorption Rate (SAR) of portable ELS31-US/ELS51-US based applications to be evaluated and approved for compliance with national and/or international regulations. Since the SAR value varies significantly with the individual product design manufacturers are advised to submit their product for approval if designed for portable use. For US markets the relevant directives are mentioned below. It is the responsibility of the manufacturer of the final product to verify whether or not further standards, recommendations or directives are in force outside these areas. Products intended for sale on US markets ES 59005/ANSI C95.1 Considerations for evaluation of human exposure to Electromagnetic Fields (EMFs) from Mobile Telecommunication Equipment (MTE) in the frequency range 30MHz - 6GHz Please note that SAR requirements are specific only for portable devices and not for mobile devices as defined below: • • Portable device: A portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Mobile device: A mobile device is defined as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structure(s) and the body of the user or nearby persons. In this context, the term ''fixed location'' means that the device is physically secured at one location and is not able to be easily moved to another location. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 36 of 46 5.3 Reference Equipment for Type Approval 38 5.3 Reference Equipment for Type Approval The Gemalto M2M reference setup submitted to type approve ELS31-US/ELS51-US (including a special approval adapter for the DSB75) is shown in the following figure1: Antenna LTE Base station GSM/ GPRS / UMTS Antenna with 1mcable USB PC ASC0 ASC1 Approval adapter for DSB75 SIMcard Power supply DSB75 SMA USB Evaluation module Evaluation module ELS31 ELS51 ELS31 ELS51 Top view Bottomview Figure 16: Reference equipment for Type Approval 1. For RF performance tests a mini-SMT/U.FL to SMA adapter with attached 6dB coaxial attenuator is chosen to connect the evaluation module directly to the GSM/UMTS test equipment instead of employing the SMA antenna connectors on the ELS31-US/ELS51-US-DSB75 adapter as shown in Figure 16. The following products are recommended: Hirose SMA-Jack/U.FL-Plug conversion adapter HRMJ-U.FLP(40) (for details see see http://www.hirose-connectors.com/ or http://www.farnell.com/ Aeroflex Weinschel Fixed Coaxial Attenuator Model 3T/4T (for details see http://www.aeroflex.com/ams/weinschel/pdfiles/wmod3&4T.pdf) ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 37 of 46 5.4 Compliance with FCC and IC Rules and Regulations 38 5.4 Compliance with FCC and IC Rules and Regulations The Equipment Authorization Certification for the Gemalto M2M reference application described in Section 5.3 will be registered under the following identifiers: • ELS31-US: FCC Identifier: QIPELS31-US Industry Canada Certification Number: 7830A-ELS31US Granted to Gemalto M2M GmbH • ELS51-US: FCC Identifier: QIPELS51-US (not yet granted) Industry Canada Certification Number: 7830A-ELS51US (not yet granted) Granted to Gemalto M2M GmbH Manufacturers of mobile or fixed devices incorporating ELS31-US/ELS51-US modules are authorized to use the FCC Grants and Industry Canada Certificates of the ELS31-US/ELS51-US modules for their own final products according to the conditions referenced in these documents. In this case, an FCC/ IC label of the module shall be visible from the outside, or the host device shall bear a second label stating "Contains FCC ID: QIPELS31-US" / "Contains FCC ID: QIPELS51-US", and accordingly “Contains IC: 7830A-ELS31US“ / “Contains IC: 7830AELS51US“. The integration is limited to fixed or mobile categorized host devices, where a separation distance between the antenna and any person of min. 20cm can be assured during normal operating conditions. For mobile and fixed operation configurations the antenna gain, including cable loss, must not exceed the limits in the following Table 9 for FCC and IC. Table 13: Antenna gain limits for FCC and IC (TBD) Operating band FCC limit IC limit Unit Maximum gain in lower operating bands with f< 1GHz (LTE Bd12) 8.72 6.10 dBi Maximum gain in higher operating bands with f=1700MHz (LTE Bd4) 5.00 5.00 dBi Maximum gain in higher operating bands with f=1900MHz (LTE Bd2) 8.01 8.01 dBi IMPORTANT: Manufacturers of portable applications incorporating ELS31-US/ELS51-US modules are required to have their final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable mobile. This is mandatory to meet the SAR requirements for portable mobiles (see Section 5.2 for detail). Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio fre- ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 38 of 46 5.4 Compliance with FCC and IC Rules and Regulations 38 quency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This Class B digital apparatus complies with Canadian ICES-003. If Canadian approval is requested for devices incorporating ELS31US / ELS51-US modules the above note will have to be provided in the English and French language in the final user documentation. Manufacturers/OEM Integrators must ensure that the final user documentation does not contain any information on how to install or remove the module from the final product. Notes (IC): (EN) This Class B digital apparatus complies with Canadian ICES-003 and RSS-210. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. (FR) Cet appareil numérique de classe B est conforme aux normes canadiennes ICES-003 et RSS-210. Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas causer d'interférence et (2) cet appareil doit accepter toute interférence, notamment les interférences qui peuvent affecter son fonctionnement. (EN) Radio frequency (RF) Exposure Information The radiated output power of the Wireless Device is below the Industry Canada (IC) radio frequency exposure limits. The Wireless Device should be used in such a manner such that the potential for human contact during normal operation is minimized. This device has also been evaluated and shown compliant with the IC RF Exposure limits under mobile exposure conditions (antennas at least 20cm from a person‘s body). (FR) Informations concernant l'exposltion aux fréquences radio (RF) La puissance de sortie émise par l'appareil de sans fiI est inférieure à la limite d'exposition aux fréquences radio d‘Industry Canada (IC). Utilisez l'appareil de sans fil de façon à minimiser les contacts humains lors du fonctionnement normal. Ce périphérique a également été évalué et démontré conforme aux limites d'exposition aux RF d'IC dans des conditions d'exposition à des appareils mobiles (les antennes se situent à moins de 20cm du corps d'une personne). ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 39 of 46 6 Document Information 43 Document Information 6.1 Revision History New document: "Cinterion® ELS31-/ELS51-US Hardware Interface Overview" v01.000a Chapter What is new -- Initial document setup. 6.2 [1] [2] [3] [4] [5] Related Documents ELS31-US/ELS51-US AT Command Set ELS31-US/ELS51-US Release Note Application Note 40: Thermal Solutions Application Note 48: SMT Module Integration Universal Serial Bus Specification Revision 2.0, April 27, 2000 6.3 Terms and Abbreviations Abbreviation Description ADC Analog-to-digital converter AGC Automatic Gain Control ANSI American National Standards Institute ARFCN Absolute Radio Frequency Channel Number ARP Antenna Reference Point ASC0/ASC1 Asynchronous Controller. Abbreviations used for first and second serial interface of the module Thermistor Constant BER Bit Error Rate BTS Base Transceiver Station CB or CBM Cell Broadcast Message CE Conformité Européene (European Conformity) CHAP Challenge Handshake Authentication Protocol CPU Central Processing Unit CS Coding Scheme CSD Circuit Switched Data CTS Clear to Send DAC Digital-to-Analog Converter DAI Digital Audio Interface ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 40 of 46 6.3 Terms and Abbreviations 43 Abbreviation Description dBm0 Digital level, 3.14dBm0 corresponds to full scale, see ITU G.711, A-law DCE Data Communication Equipment (typically modems, e.g. Gemalto M2M module) DCS 1800 Digital Cellular System, also referred to as PCN DRX Discontinuous Reception DSB Development Support Box DSP Digital Signal Processor DSR Data Set Ready DTE Data Terminal Equipment (typically computer, terminal, printer or, for example, GSM application) DTR Data Terminal Ready DTX Discontinuous Transmission EFR Enhanced Full Rate EGSM Enhanced GSM EIRP Equivalent Isotropic Radiated Power EMC Electromagnetic Compatibility ERP Effective Radiated Power ESD Electrostatic Discharge ETS European Telecommunication Standard FCC Federal Communications Commission (U.S.) FDMA Frequency Division Multiple Access FR Full Rate GMSK Gaussian Minimum Shift Keying GPIO General Purpose Input/Output GPRS General Packet Radio Service GSM Global Standard for Mobile Communications HiZ High Impedance HR Half Rate HSIC High-Speed Inter-Chip I/O Input/Output IC Integrated Circuit IMEI International Mobile Equipment Identity ISO International Standards Organization ITU International Telecommunications Union kbps kbits per second LED Light Emitting Diode Li-Ion/Li+ Lithium-Ion Li battery Rechargeable Lithium Ion or Lithium Polymer battery LTE Long Term Evolution ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 41 of 46 6.3 Terms and Abbreviations 43 Abbreviation Description Mbps Mbits per second MMI Man Machine Interface MO Mobile Originated MS Mobile Station (GSM module), also referred to as TE MSISDN Mobile Station International ISDN number MT Mobile Terminated NTC Negative Temperature Coefficient OEM Original Equipment Manufacturer PA Power Amplifier PAP Password Authentication Protocol PBCCH Packet Switched Broadcast Control Channel PCB Printed Circuit Board PCL Power Control Level PCM Pulse Code Modulation PCN Personal Communications Network, also referred to as DCS 1800 PCS Personal Communication System, also referred to as GSM 1900 PLL Phase Locked Loop PPP Point-to-point protocol PSK Phase Shift Keying PSU Power Supply Unit R&TTE Radio and Telecommunication Terminal Equipment RAM Random Access Memory RF Radio Frequency RLS Radio Link Stability RoHS Restriction of the use of certain hazardous substances in electrical and electronic equipment. RTS Request to Send Rx Receive Direction SAR Specific Absorption Rate SAW Surface Acoustic Wave SDIO Secure Digital Input Output SELV Safety Extra Low Voltage SIM Subscriber Identification Module SMD Surface Mount Device SMS Short Message Service SMT Surface Mount Technology SRAM Static Random Access Memory TA Terminal adapter (e.g. GSM module) ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 42 of 46 6.3 Terms and Abbreviations 43 Abbreviation Description TDMA Time Division Multiple Access TE Terminal Equipment, also referred to as DTE TLS Transport Layer Security Tx Transmit Direction UART Universal asynchronous receiver-transmitter URC Unsolicited Result Code USSD Unstructured Supplementary Service Data VSWR Voltage Standing Wave Ratio ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 43 of 46 6.4 Safety Precaution Notes 43 6.4 Safety Precaution Notes The following safety precautions must be observed during all phases of the operation, usage, service or repair of any cellular terminal or mobile incorporating ELS31-US/ELS51-US. Manufacturers of the cellular terminal are advised to convey the following safety information to users and operating personnel and to incorporate these guidelines into all manuals supplied with the product. Failure to comply with these precautions violates safety standards of design, manufacture and intended use of the product. Gemalto M2M assumes no liability for customer’s failure to comply with these precautions. When in a hospital or other health care facility, observe the restrictions on the use of mobiles. Switch the cellular terminal or mobile off, if instructed to do so by the guidelines posted in sensitive areas. Medical equipment may be sensitive to RF energy. The operation of cardiac pacemakers, other implanted medical equipment and hearing aids can be affected by interference from cellular terminals or mobiles placed close to the device. If in doubt about potential danger, contact the physician or the manufacturer of the device to verify that the equipment is properly shielded. Pacemaker patients are advised to keep their hand-held mobile away from the pacemaker, while it is on. Switch off the cellular terminal or mobile before boarding an aircraft. Make sure it cannot be switched on inadvertently. The operation of wireless appliances in an aircraft is forbidden to prevent interference with communications systems. Failure to observe these instructions may lead to the suspension or denial of cellular services to the offender, legal action, or both. Do not operate the cellular terminal or mobile in the presence of flammable gases or fumes. Switch off the cellular terminal when you are near petrol stations, fuel depots, chemical plants or where blasting operations are in progress. Operation of any electrical equipment in potentially explosive atmospheres can constitute a safety hazard. Your cellular terminal or mobile receives and transmits radio frequency energy while switched on. Remember that interference can occur if it is used close to TV sets, radios, computers or inadequately shielded equipment. Follow any special regulations and always switch off the cellular terminal or mobile wherever forbidden, or when you suspect that it may cause interference or danger. Road safety comes first! Do not use a hand-held cellular terminal or mobile when driving a vehicle, unless it is securely mounted in a holder for speakerphone operation. Before making a call with a hand-held terminal or mobile, park the vehicle. Speakerphones must be installed by qualified personnel. Faulty installation or operation can constitute a safety hazard. IMPORTANT! Cellular terminals or mobiles operate using radio signals and cellular networks. Because of this, connection cannot be guaranteed at all times under all conditions. Therefore, you should never rely solely upon any wireless device for essential communications, for example emergency calls. Remember, in order to make or receive calls, the cellular terminal or mobile must be switched on and in a service area with adequate cellular signal strength. Some networks do not allow for emergency calls if certain network services or phone features are in use (e.g. lock functions, fixed dialing etc.). You may need to deactivate those features before you can make an emergency call. Some networks require that a valid SIM card be properly inserted in the cellular terminal or mobile. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 44 of 46 7 Appendix 45 Appendix 7.1 List of Parts and Accessories Table 14: List of parts and accessories Description Supplier Ordering information ELS31-US Gemalto M2M Standard module Gemalto M2M IMEI: Packaging unit (ordering) number: L30960-N4520-A200 Module label number: S30960-S4520-A200-11 Customer IMEI module Packaging unit (ordering) number: L30960-N4525-A200 Module label number: S30960-S4520-A200-11 ELS51-US Gemalto M2M Standard module Gemalto M2M IMEI: Packaging unit (ordering) number: L30960-N4550-A200 Module label number: S30960-S4550-A200-11 Customer IMEI module Packaging unit (ordering) number: L30960-N4555-A200 Module label number: S30960-S4555-A200-11 ELS31-US Evaluation Module Gemalto M2M Ordering number: L30960-N4521-A200 ELS51-US Evaluation Module Gemalto M2M Ordering number: L30960-N4551-A200 DSB75 Evaluation Kit Gemalto M2M Ordering number: L36880-N8811-A100 DSB Mini Compact Evaluation Board Gemalto M2M Ordering number: L30960-N0030-A100 Starter Kit B80 Gemalto M2M Ordering Number L30960-N0040-A100 Multi-Adapter R1 for mounting ELS31-US/ELS51-US evaluation modules onto DSB75 Gemalto M2M Ordering number: L30960-N0010-A100 Approval adapter for mounting ELS31-US/ELS51-US evaluation modules onto DSB75 Gemalto M2M Ordering number: L30960-N2301-A100 SIM card holder incl. push button ejector and slide-in tray Molex Ordering numbers: 91228 91236 Sales contacts are listed in Table 15. 1. Note: At the discretion of Gemalto M2M, module label information can either be laser engraved on the module’s shielding or be printed on a label adhered to the module’s shielding. ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 Cinterion® ELS31-/ELS51-US Hardware Interface Overview Page 45 of 46 7.1 List of Parts and Accessories 45 Table 15: Molex sales contacts (subject to change) Molex For further information please click: http://www.molex.com Molex Deutschland GmbH Otto-Hahn-Str. 1b 69190 Walldorf Germany Phone: +49-6227-3091-0 Fax: +49-6227-3091-8100 Email: mxgermany@molex.com American Headquarters Lisle, Illinois 60532 U.S.A. Phone: +1-800-78MOLEX Fax: +1-630-969-1352 Molex China Distributors Beijing, Room 1311, Tower B, COFCO Plaza No. 8, Jian Guo Men Nei Street, 100005 Beijing P.R. China Phone: +86-10-6526-9628 Fax: +86-10-6526-9730 Molex Singapore Pte. Ltd. 110, International Road Jurong Town, Singapore 629174 Molex Japan Co. Ltd. 1-5-4 Fukami-Higashi, Yamato-City, Kanagawa, 242-8585 Japan Phone: +65-6-268-6868 Fax: +65-6-265-6044 Phone: +81-46-265-2325 Fax: +81-46-265-2365 ELS31-US_ELS51-US_HIO_v01.000a Confidential / Preliminary 2016-12-28 46 About Gemalto Gemalto (Euronext NL0000400653 GTO) is the world leader in digital security with 2015 annual revenues of €3.1 billion and blue-chip customers in over 180 countries. Our 14,000+ employees operate out of 118 offices, 45 personalization and data centers, and 27 research and software development centers located in 49 countries. Gemalto develops secure embedded software and secure products which we design and personalize. Our platforms and services manage these secure products, the confidential data they contain and the trusted end-user services they enable. Our innovations enable our clients to offer trusted and convenient digital services to billions of individuals. Gemalto thrives with the growing number of people using its solutions to interact with the digital and wireless world. For more information please visit m2m.gemalto.com, www.facebook.com/gemalto, or Follow@gemaltom2m on twitter. Gemalto M2M GmbH Werinherstrasse 81 81541 Munich Germany M2M.GEMALTO.COM © Gemalto 2016. All rights reserved. Gemalto, the Gemalto logo, are trademarks and service marks of Gemalto and are registered in certain countries. April 2013 We are at the heart of the rapidly evolving digital society. Billions of people worldwide increasingly want the freedom to communicate, travel, shop, bank, entertain and work - anytime, everywhere - in ways that are enjoyable and safe. Gemalto delivers on their expanding needs for personal mobile services, payment security, authenticated cloud access, identity and privacy protection, eHealthcare and eGovernment efficiency, convenient ticketing and dependable machine-tomachine (M2M) applications.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : chinrich Create Date : 2016:12:28 11:02:11Z Modify Date : 2016:12:28 11:26:21+01:00 Language : en XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Producer : Acrobat Distiller 11.0 (Windows) Creator Tool : FrameMaker 2015.0.5 Metadata Date : 2016:12:28 11:26:21+01:00 Format : application/pdf Title : hid_elsx1-us.book Creator : chinrich Document ID : uuid:d7a8e2a5-3f3f-4029-9c48-635d19fb5899 Instance ID : uuid:3e783096-f35a-4c74-a0b6-c3704e372305 Page Mode : UseOutlines Page Count : 46EXIF Metadata provided by EXIF.tools