THALES DIS AlS Deutschland HMS1 Quadband GSM/GPRS/UMTS/HSDPA Module User Manual HMS1 Hardware Interface Description

Gemalto M2M GmbH Quadband GSM/GPRS/UMTS/HSDPA Module HMS1 Hardware Interface Description

Integration Manual

Download: THALES DIS AlS Deutschland HMS1 Quadband GSM/GPRS/UMTS/HSDPA Module User Manual HMS1   Hardware Interface Description
Mirror Download [FCC.gov]THALES DIS AlS Deutschland HMS1 Quadband GSM/GPRS/UMTS/HSDPA Module User Manual HMS1   Hardware Interface Description
Document ID716482
Application IDOFEeHzuqmIMWInzCA4LCug==
Document DescriptionIntegration Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize94.58kB (1182191 bits)
Date Submitted2006-10-17 00:00:00
Date Available2006-10-17 00:00:00
Creation Date2006-08-21 09:11:13
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2006-08-21 09:17:55
Document TitleHMS1 - Hardware Interface Description
Document CreatorAcrobat PDFMaker 7.0.7 für Word
Document Author: pd36718

Version:
DocID:
01.62
HMS1_HD_V01.62
Hardware Interface Description
HMS1
Siemens Cellular Engine
HMS1 Hardware Interface Description
Confidential / Preliminary
Document Name:
HMS1 Hardware Interface Description
Version:
01.62
Date:
August 21, 2006
DocId:
HMS1_HD_V01.62
Status:
Confidential / Preliminary
General note
Product is deemed accepted by Recipient and is provided without interface to Recipient´s products.
The Product constitutes pre-release version and code and may be changed substantially before
commercial release. The Product is provided on an “as is” basis only and may contain deficiencies or
inadequacies. The Product is provided without warranty of any kind, express or implied. To the
maximum extent permitted by applicable law, Siemens further disclaims all warranties, including
without limitation any implied warranties of merchantability, fitness for a particular purpose and
noninfringement of third-party rights. The entire risk arising out of the use or performance of the
Product and documentation remains with Recipient. This Product is not intended for use in life support
appliances, devices or systems where a malfunction of the product can reasonably be expected to
result in personal injury. Applications incorporating the described product must be designed to be in
accordance with the technical specifications provided in these guidelines. Failure to comply with any of
the required procedures can result in malfunctions or serious discrepancies in results. Furthermore, all
safety instructions regarding the use of mobile technical systems, including GSM products, which also
apply to cellular phones must be followed. Siemens AG customers using or selling this product for use
in any applications do so at their own risk and agree to fully indemnify Siemens for any damages
resulting from illegal use or resale. To the maximum extent permitted by applicable law, in no event
shall Siemens or its suppliers be liable for any consequential, incidental, direct, indirect, punitive or
other damages whatsoever (including, without limitation, damages for loss of business profits,
business interruption, loss of business information or data, or other pecuniary loss) arising out the use
of or inability to use the Product, even if Siemens has been advised of the possibility of such damages.
Subject to change without notice at any time.
Copyright
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its
contents and communication thereof to others without express authorization are prohibited. Offenders
will be held liable for payment of damages. All rights created by patent grant or registration of a utility
model or design patent are reserved.
Copyright © Siemens AG 2006
HMS1_HD_V01.62
Page 2 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
Contents
0.
Document History ...................................................................................................... 5
1.
Introduction ................................................................................................................ 6
1.1. Related Documents............................................................................................. 6
1.2. Terms and Abbreviations .................................................................................... 6
1.3. Type Approval ..................................................................................................... 9
1.4. Safety Precautions ............................................................................................ 11
2.
Product Concept ...................................................................................................... 13
2.1. Key Features at a Glance.................................................................................. 13
2.2. HMS1 System Overview ................................................................................... 15
2.3. Circuit Concept.................................................................................................. 16
3.
Application Interface................................................................................................ 17
3.1. Operating Modes............................................................................................... 18
3.2. Power Supply .................................................................................................... 19
3.2.1. Minimizing Power Losses .................................................................... 19
3.3. Power-Up / Power-Down Scenarios .................................................................. 20
3.3.1. Turn on HMS1 ..................................................................................... 20
3.3.2. Turn off HMS1 ..................................................................................... 20
3.4. Power Saving .................................................................................................... 21
3.5. RTC Backup...................................................................................................... 21
3.6. USIM Interface .................................................................................................. 21
3.7. USB Interface.................................................................................................... 21
3.8. Control Signals.................................................................................................. 22
3.8.1. PWR_IND Signal ................................................................................. 22
3.8.2. Status Signals ..................................................................................... 22
4.
Antenna Interface ..................................................................................................... 23
4.1. Antenna Installation........................................................................................... 23
4.1.1. Test Antenna ....................................................................................... 23
5.
Electrical, Reliability and Radio Characteristics .................................................... 24
5.1. Absolute Maximum Ratings............................................................................... 24
5.2. Operating Temperatures ................................................................................... 24
5.3. Storage Conditions............................................................................................ 25
5.4. Reliability Characteristics .................................................................................. 26
5.5. Pin Assignment and Signal Description ............................................................. 27
5.6. Power Supply Ratings ....................................................................................... 31
5.7. Air Interface....................................................................................................... 32
5.8. Electrostatic Discharge...................................................................................... 34
6.
Mechanics................................................................................................................. 35
6.1. Mechanical Dimensions HMS1.......................................................................... 35
7.
Board-to-Board Application Connector.................................................................. 37
8.
Reference Approval ................................................................................................. 38
8.1. Reference Equipment for Type Approval........................................................... 38
8.2. Compliance with FCC Rules and Regulations ................................................... 39
HMS1_HD_V01.62
Page 3 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
Tables
Table 1: Directives..................................................................................................................9
Table 2: Standards of North American type approval..............................................................9
Table 2: Standards of European type approval.......................................................................9
Table 3: Requirements of quality ..........................................................................................10
Table 4: Overview of operating modes .................................................................................18
Table 5: Absolute maximum ratings......................................................................................24
Table 6: Ambient temperature according to IEC 60068-2 (without forced air circulation) ......24
Table 7: Storage conditions ..................................................................................................25
Table 8: Summary of reliability test conditions......................................................................26
Table 9: Signal description ...................................................................................................28
Table 10: Power supply ratings ............................................................................................31
Table 11: Air Interface GSM .................................................................................................32
Table 12: Air Interface UMTS ...............................................................................................33
Table 13: Measured electrostatic values...............................................................................34
Table 14: Electrical and mechanical characteristics of the 80 pin board-to-board connector.37
Figures
Figure 1: HSM system overview ...........................................................................................15
Figure 2: HMS1 schematic overview ....................................................................................16
Figure 3: Power supply limits during transmit burst...............................................................20
Figure 5: Internal antenna for HMS.......................................................................................23
Figure 6: Pin assignments on board-to-board connector ......................................................27
Figure 7: HMS1 Top View (prelim.).......................................................................................35
Figure 8: HMS1 Dimensions (prelim.)...................................................................................36
Figure 9: Mechanical dimensions of 80 pin board-to-board connector ..................................37
Figure 10: Reference equipment for Type Approval .............................................................38
HMS1_HD_V01.62
Page 4 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
0.
Document History
New document: "HMS1 Hardware Interface Description" Version 01.62
Chapter
What is new
All
Initial document setup.
HMS1_HD_V01.62
Page 5 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
1.
Introduction
This document describes the hardware of the Siemens HMS1 module that connects to a
cellular device application and the air interface. It helps you quickly retrieve interface
specifications, electrical and mechanical details and information on the requirements to be
considered for integrating further components.
The HMS1 module is a single band WCDMA, quad band GSM/GPRS data modem and
features high downlink speeds using HSDPA. It can be connected to a standard PC via USB
interface for high speed data communication, such as email, web browsing, data base
retrieval, server access, as well as audio and video streaming.
1.1. Related Documents
[1]
[2]
HMS1 AT Command Set, Version 01.62
DSB75 Support Box - Evaluation Kit for Siemens Cellular Engines
1.2. Terms and Abbreviations
Abbreviation Description
A/D
Analog-to-Digital Converter
AF
Audio Frequency
AFC
Automatic Frequency Control
AGC
Automatic Gain Control
AMR
Adaptive Multi Rate
ARP
Antenna Reference Point
ASIC
Application Specific Integrated Circuit
BB
Baseband
CPU
Central Processing Unit
CR
Change Request
CTR
Common Technical Regulation
DAI
Digital Audio Interface
/DCD
Data Carrier Detect
DFC
Digital Frequency Centering
DSB
Development Support Board
DSP
Digital Signal Processor
/DSR
Data Set Ready
/DTR
Data Terminal Ready
DTX
Discontinuous transmission
HMS1_HD_V01.62
Page 6 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
EFR
Enhanced Full Rate
EMC
Electro Magnetic Compatibility
EGSM
Enhanced GSM
ESD
Electrostatic Discharge
ESR
Equivalent Serial Resistance
ETS
European Telecommunication Standard
FE
Front-End
FFC
Flat Flexible Cable
FR
Full Rate
GMSK
Gaussian Minimum Shift Keying
GSC
(Type of antenna connector)
GSM
Global Standard for Mobile Communications
HR
Half Rate
HSDPA
High Speed Downlink Packet Access
HW
Hardware
IC
Integrated Circuit
IF
Intermediate Frequency
IMEI
International Mobile Equipment Identity
I/O
Input/Output
ISO
International Standards Organization
ITU
International Telecommunications Union
LDO
Low Drop Out
LFBGA
Low-Profile Fine-Pitch Ball Grid Array
Li-Ion
Lithium-Ion
LNA
Low Noise Amplifier
LO
Local Oscillator
Mbps
Mbit per second
MMI
Man Machine Interface
MTBF
Mean Time Between Failures
NTC
Negative Temperature Coefficient
OC
Offset Compensation
OTP
One Time Programmable
PA(C)
Power Amplifier (Control)
PCB
Printed Circuit Board
PCM
Pulse Code Modulation
PD
Power Down
PGC
Programmable Gain-Controlled Amplifier
HMS1_HD_V01.62
Page 7 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
PLL
Phase Locked Loop
PSU
Power Supply Unit
RAM
Random Access Memory
RF
Radio Frequency
/RING
Ring Indication
ROM
Read-Only Memory
RTC
Real Time Clock
/RXD
Receive direction
Rx
Receive direction
SAW
Surface Acoustical Wave Filter
SELV
Safety Extra Low Voltage
SIM
Subscriber Identification Module
SMS
Short Message Service
SRAM
Static Random Access Memory
SW
Software
TBR
Technical Based Regulation
TBD
To Be Defined
TBI
To Be Inserted
TDD
Time Division Duplex
TDMA
Time Division Multiple Access
/TXD
Transmit direction
Tx
Transmit direction
UART
Universal Asynchronous Receiver Transmitter
VCO
Voltage Controlled Oscillator
VCXO
Voltage Controlled Quartz Oscillator
VSWR
Voltage Standing Wave Ratio
HMS1_HD_V01.62
Page 8 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
1.3. Type Approval
HMS1 has been approved to comply with the directives and standards listed below.
Table 1: Directives
99/05/EC
Directive of the European Parliament and of the council of 9
March 1999 on radio equipment and telecommunications terminal
equipment and the mutual recognition of their conformity (in short
referred to as R&TTE Directive 1999/5/EC).
The product is labeled with the CE conformity mark
89/336/EC
Directive on electromagnetic compatibility
73/23/EC
Directive on electrical equipment designed for use within certain
voltage limits (Low Voltage Directive)
2002/95/EC
Directive of the European Parliament and of the
Council of 27 January 2003 on the restriction of the
use of certain hazardous substances in electrical
and electronic equipment (RoHS)
Table 2: Standards of North American type approval
CFR Title 47
Code of Federal Regulations, Part 22 and Part 24
(Telecommunications, PCS); US Equipment Authorization FCC
NAPRD.03 V3.5.1
Overview of PCS Type certification review board Mobile
Equipment Type Certification and IMEI control
PCS Type Certification Review board (PTCRB)
RSS133 (Issue2)
Canadian Standard
Table 3: Standards of European type approval
3GPP TS 51.010-1
Digital cellular telecommunications system (Phase 2); Mobile
Station (MS) conformance specification
ETSI EN 301 511
V9.0.2
Candidate Harmonized European Standard (Telecommunications
series) Global System for Mobile communications (GSM);
Harmonized standard for mobile stations in the GSM 900 and
DCS 1800 bands covering essential requirements under article
3.2 of the R&TTE directive (1999/5/EC) (GSM 13.11 version 7.0.1
Release 1998)
GCF-CC V3.xx.0
Global Certification Forum - Certification Criteria
ETSI EN 301 489-1
V1.4.1
Candidate Harmonized European Standard (Telecommunications
series) Electro Magnetic Compatibility and Radio spectrum Matters
(ERM); Electro Magnetic Compatibility (EMC) standard for radio
equipment and services; Part 1: Common Technical Requirements
HMS1_HD_V01.62
Page 9 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
ETSI EN 301 489-7
V1.2.1 (2000-09)
Candidate Harmonized European Standard (Telecommunications
series) Electro Magnetic Compatibility and Radio spectrum
Matters (ERM); Electro Magnetic Compatibility (EMC) standard for
radio equipment and services; Part 7: Specific conditions for
mobile and portable radio and ancillary equipment of digital
cellular radio telecommunications systems (GSM and DCS)
IEC/EN 60950-1
(2001)
Safety of information technology equipment (2000)
Table 4: Requirements of quality
IEC 60068
Environmental testing
DIN EN 60529
IP codes
SAR requirements specific to portable mobiles
Mobile phones, PDAs or other portable transmitters and receivers incorporating a GSM
module must be in accordance with the guidelines for human exposure to radio frequency
energy. This requires the Specific Absorption Rate (SAR) of portable HMS1 based
applications to be evaluated and approved for compliance with national and/or international
regulations.
Since the SAR value varies significantly with the individual product design manufacturers are
advised to submit their product for approval if designed for portable use. For European and
US markets the relevant directives are mentioned below. It is the responsibility of the
manufacturer of the final product to verify whether or not further standards, recommendations
or directives are in force outside these areas.
Products intended for sale on US markets
ES 59005/ANSI C95.1 Considerations for evaluation of
human exposure to
Electromagnetic Fields (EMFs) from Mobile Telecommunication
Equipment (MTE) in the frequency range 30MHz - 6GHz
Products intended for sale on European markets
EN 50360
Product standard to demonstrate the compliance of mobile phones
with the basic restrictions related to human exposure to
electromagnetic fields (300MHz - 3GHz)
HMS1_HD_V01.62
Page 10 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
1.4. Safety Precautions
The following safety precautions must be observed during all phases of the operation, usage,
service or repair of any cellular terminal or mobile incorporating HMS1. Manufacturers of the
cellular terminal are advised to convey the following safety information to users and
operating personnel and to incorporate these guidelines into all manuals supplied with the
product. Failure to comply with these precautions violates safety standards of design,
manufacture and intended use of the product. Siemens AG assumes no liability for
customer’s failure to comply with these precautions.
When in a hospital or other health care facility, observe the restrictions on the
use of mobiles. Switch the cellular terminal or mobile off, if instructed to do so
by the guidelines posted in sensitive areas. Medical equipment may be
sensitive to RF energy.
The operation of cardiac pacemakers, other implanted medical equipment
and hearing aids can be affected by interference from cellular terminals or
mobiles placed close to the device. If in doubt about potential danger, contact
the physician or the manufacturer of the device to verify that the equipment is
properly shielded. Pacemaker patients are advised to keep their hand-held
mobile away from the pacemaker, while it is on.
Switch off the cellular terminal or mobile before boarding an aircraft. Make
sure it cannot be switched on inadvertently. The operation of wireless
appliances in an aircraft is forbidden to prevent interference with
communications systems. Failure to observe these instructions may lead to
the suspension or denial of cellular services to the offender, legal action, or
both.
Do not operate the cellular terminal or mobile in the presence of flammable
gases or fumes. Switch off the cellular terminal when you are near petrol
stations, fuel depots, chemical plants or where blasting operations are in
progress. Operation of any electrical equipment in potentially explosive
atmospheres can constitute a safety hazard.
Your cellular terminal or mobile receives and transmits radio frequency
energy while switched on. Remember that interference can occur if it is used
close to TV sets, radios, computers or inadequately shielded equipment.
Follow any special regulations and always switch off the cellular terminal or
mobile wherever forbidden, or when you suspect that it may cause
interference or danger.
Road safety comes first! Do not use a hand-held cellular terminal or mobile
when driving a vehicle, unless it is securely mounted in a holder for
speakerphone operation. Before making a call with a hand-held terminal or
mobile, park the vehicle.
Speakerphones must be installed by qualified personnel. Faulty installation or
operation can constitute a safety hazard.
HMS1_HD_V01.62
Page 11 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
SOS
IMPORTANT!
Cellular terminals or mobiles operate using radio signals and cellular
networks. Because of this, connection cannot be guaranteed at all times
under all conditions. Therefore, you should never rely solely upon any
wireless device for essential communications, for example emergency calls.
Remember, in order to make or receive calls, the cellular terminal or mobile
must be switched on and in a service area with adequate cellular signal
strength.
Some networks do not allow for emergency calls if certain network services or
phone features are in use (e.g. lock functions, fixed dialing etc.). You may
need to deactivate those features before you can make an emergency call.
Some networks require that a valid SIM card be properly inserted in the
cellular terminal or mobile.
HMS1_HD_V01.62
Page 12 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
2.
Product Concept
2.1. Key Features at a Glance
Feature
Implementation
General
Frequency bands
Quad band: GSM 850/900/1800/1900MHz
Single band: WCDMA 2100
GSM class
Small MS
Output power
(according to
Release 99, V5)
Class 4 (+33dBm ±2dB) for EGSM850
Class 4 (+33dBm ±2dB) for EGSM900
Class 1 (+30dBm ±2dB) for GSM1800
Class 1 (+30dBm ±2dB) for GSM1900
Class E2 (+27dBm ± 3dB) for GSM 850 8-PSK
Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1900 8-PSK
Class 3 (+24dBm +1/-3dB) for UMTS 2100, WCDMA FDD BdI
The values stated above are maximum limits. According to
Release 99, Version 5, the maximum output power in a multislot
configuration may be lower. The nominal reduction of maximum
output power varies with the number of uplink timeslots used and
amounts to 3.0dB for 2Tx.
Power supply
3.6V, supplied by limited power source
Ambient operating
temperature according
to IEC 60068-2
Normal operation
0°C to 55°C
Physical
Dimensions: 70mm x 49.7mm x 5mm
Weight: approx. 17g
RoHS
All hardware components fully compliant with EU RoHS Directive
GSM / GPRS / EGPRS / UMTS features
Data transfer
UMTS
• FDD Mode
• HSDPA Mode Cat. 11.12
•
GPRS
• Multislot Class 10
• Full PBCCH support
• Mobile Station Class B
• Coding Scheme 1 – 4
HMS1_HD_V01.62
Page 13 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
Feature
Implementation
EGPRS
• Multislot Class 10
• Mobile Station Class B
• Modulation and Coding Scheme MCS 1 – 9
CSD
• V.110, RLP, non-transparent
• GSM: 2.4, 4.8, 9.6, 14.4kbps
• UMTS: 57.6kbps
SMS
•
•
•
Fax
Group 3; Class 1, Class 2
Point-to-point MT and MO
Cell broadcast
Text and PDU mode
Software
AT commands
AT-Hayes GSM 07.05 and 07.07, Qualcomm
AT command Set
Firmware update
Generic update from host application over USB.
Interfaces
USB
Supports a USB 1.1 Full Speed (12Mbit/s) device interface.
SIM
SIM card reader on board
Antenna
External antenna can be connected via antenna pads. For test
purposes a 50Ohm antenna can be connected via coaxial switch
(Hirose MS-156NB).
Module interface
80 pin board-to-board connector
Power on/off, Reset
Power on/off
•
•
Switch-on by hardware pin IGT
Switch-off by AT command
Reset
•
•
Orderly shutdown and reset by AT command
Emergency reset by hardware pins EMERG_RST
Evaluation kit
DSB
HMS1_HD_V01.62
DSB Evaluation Board designed to test and type approve
Siemens cellular engines and provide a sample configuration for
application engineering.
Page 14 of 39
2006-08-21
s
HMS1 Hardware Interface Description
Confidential / Preliminary
2.2. HMS1 System Overview
Antenna
Interface
Sim card
holder
Power
Supply
USB
Figure 1: HSM system overview
HMS1_HD_V01.62
Page 15 of 39
2006-08-21
s
HMS1 Hardware Interface Description
Confidential / Preliminary
2.3. Circuit Concept
Figure 2 shows a block diagram of the HMS module and illustrates the major functional
components:
Base band block:
•
WCDMA/GSM Baseband Controller
•
Power supply unit
•
Flash/SDRAM memory
•
External Interface, 80 pin board-to-board connector
RF section:
•
RF WCDMA Receiver
•
RF WCDMA Transmitter
•
RF Power Amplifiers
•
EPCOS receive SAWs (according to variant – see below)
•
Antenna Connector
SDRAM
NAND
Flash
SIM
Card
Holder
B2B
Connector
Frontend
GSM
PA
Transceiver
WCDMA
PA
Processor
Power
Management
Receiver
USB
Green
Blue
PWR_IND
EMERG_RST
CONTROL
IGT
VDDLP
TCTCXO
19.2MHz
48MHz
VEXT
BATT+
32. 786kHz
Figure 2: HMS1 schematic overview
HMS1_HD_V01.62
Page 16 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
3.
Application Interface
HMS1 is equipped with an 80 pin board-to-board connector that connects to the external
application. The host interface incorporates several sub-interfaces described in the following
chapters:
•
•
•
•
•
Operation Modes - see Section 3.1
Power supply - see Section 3.2
SIM interface - see Section 3.6
Serial interface USB - see Section 3.7.
Status and control lines: IGT, EMERG_RST, PWR_IND, STATUS1/2 – see Table 10
HMS1_HD_V01.62
Page 17 of 39
2006-08-21
s
HMS1 Hardware Interface Description
Confidential / Preliminary
3.1. Operating Modes
The table below briefly summarizes the various operating modes referred to in the following
chapters.
Table 5: Overview of operating modes
Normal operation GSM / GPRS
SLEEP
POWER DOWN
HMS1_HD_V01.62
Tbd.
GSM IDLE
Software is active. Once registered to the GSM
network, paging with BTS is carried out. The
module is ready to send and receive.
GSM DATA
Connection between two subscribers is in
progress. Power consumption depends on network
coverage individual settings.
GPRS IDLE
EGPRS IDLE
Module is ready for GPRS/EGPRS data transfer,
but no data is currently sent or received. Power
consumption depends on network settings and
GPRS/EGPRS
configuration
(e.g.
multislot
settings).
GPRS DATA
EGPRS DATA
GPRS/EGPRS data transfer in progress. Power
consumption depends on network settings (e.g.
power control level), uplink / downlink data rates,
GPRS/EGPRS configuration (e.g. used multislot
settings) and reduction of maximum output power.
UMTS IDLE
Software is active. Once registered to the UMTS
network, paging with BTS is carried out. The
module is ready to send and receive.
UMTS DATA
UMTS Data Transfer in progress.
HSDPA
HSDPA High Speed Data connection in Downlink
Direction.
Normal shutdown after sending the AT command.
Operating voltage (connected to BATT+) remains applied.
Page 18 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
3.2. Power Supply
HMS1 needs to be connected to a power supply at the B2B connector (5 pins each BATT+
and GND).
The power supply of HMS1 has to be a single voltage source at BATT+. It must be able to
provide the peak current during the GSM uplink transmission.
All the key functions for supplying power to the device are handled by the power
management section of the analog controller. This IC provides the following features:
•
Stabilizes the supply voltages for the GSM / UMTS baseband using low drop linear
voltage regulators.
•
Switches the module's power voltages for the power-up and -down procedures.
•
Delivers, across the VEXT pin, a regulated voltage for an external application. This
voltage is not available in Power-down mode.
•
SIM switch to provide SIM power supply.
3.2.1.Minimizing Power Losses
When designing the power supply for your application please pay specific attention to power
losses. Ensure that the input voltage VBATT+ never drops below 3.3V on the HMS1 board, not
even in a GSM transmit burst where current consumption can rise to typical peaks of 2A. It
should be noted that HMS1 switches off when exceeding these limits. Any voltage drops that
may occur in a transmit burst should not exceed 400mV.
In IDLE and SLEEP mode, the module switches off if the minimum battery voltage (Vbattmin)
is reached.
Example:
VImin = 3.3V
Dmax = 0.4V
Vbattmin = VImin + Dmax
Vbattmin = 3.3V + 0.4V = 3.7V
The best approach to reducing voltage drops is to use a board-to-board connection as
recommended, and a low impedance power source. The resistance of the power supply lines
on the host board and of a battery pack should also be considered.
Note:
If the application design requires an adapter cable between both board-to-board
connectors, use a flex cable as short as possible in order to minimize power
losses.
HMS1_HD_V01.62
Page 19 of 39
2006-08-21
s
HMS1 Hardware Interface Description
Confidential / Preliminary
Example: If the length of the flex cable reaches the maximum length of 100mm, this
connection may cause, for example, a resistance of 30mΩ in the BATT+ line and
30mΩ in the GND line. As a result, a 2A transmit burst would add up to a total
voltage drop of 120mV. Plus, if a battery pack is involved, further losses may
occur due to the resistance across the battery lines and the internal resistance of
the battery including its protection circuit.
Transmit
burst 2A
Transmit
burst 2A
BATT+
Drop
min. 3.3V
Rippl
Figure 3: Power supply limits during transmit burst
3.3. Power-Up / Power-Down Scenarios
In general, be sure not to turn on HMS1 while it is beyond the safety limits of voltage and
temperature. HMS1 would immediately switch off after having started and detected these
inappropriate conditions. In extreme cases this can cause permanent damage to the module.
3.3.1.Turn on HMS1
When the HMS1 module is in Power-down mode, it can be started to Normal mode or
Airplane mode by driving the IGT (ignition) line to ground. This must be accomplished with an
open drain/collector driver to avoid current flowing into this pin.
3.3.1.1.
Reset or Turn off HMS1 in Case of Emergency
Caution: Use the EMERG_RST pin only when, due to serious problems, the software is not
responding for more than 5 seconds. Pulling the EMERG_RST pin causes the loss of all
information stored in the volatile memory. Therefore, this procedure is intended only for use
in case of emergency, e.g. if HMS1 does not respond, if reset or shutdown via AT command
fails.
The EMERG_RST signal is available on the application interface.
3.3.2. Turn off HMS1
HMS1 can be turned off by Normal shutdown: Software controlled by AT command.
Be sure not to disconnect the supply voltage VBATT+. Otherwise you run the risk of losing
data.
HMS1_HD_V01.62
Page 20 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
3.4. Power Saving
Intended for power saving, SLEEP mode reduces the functionality of the HMS1 to a
minimum and thus minimizes the current consumption.
The different sleep modes will be specified later.
3.5. RTC Backup
The internal Real Time Clock of HMS1 is supplied from a separate voltage regulator in the
analog controller which is also active when HMS1 is in POWER DOWN status.
In addition, you can use the VDDLP pin on the board-to-board connector to backup the RTC
from an external capacitor or a battery (rechargeable or non-chargeable). The capacitor or
battery is charged by the power management controller of HMS1. If the voltage supply at
BATT+ is disconnected, the RTC can be powered by the capacitor or battery. The size of the
capacitor determines the duration of buffering when no voltage is applied to HMS1, i.e. the
larger the capacitor the longer HMS1 will save the date and time.
3.6. USIM Interface
The base band processor has an integrated SIM interface compatible with the 34.121 USIM
Testing IC Card standard. This is wired to an integrated SIM card holder. The USIM interface
supports 3V and 1.8V USIM cards.
Note: No guarantee can be given, nor any liability accepted, if loss of data is encountered
after removing the SIM card during operation.
Also, no guarantee can be given for properly initializing any SIM card that the user
inserts after having removed a SIM card during operation.
3.7. USB Interface
HMS1 supports a USB 1.1 Full Speed (12Mbit/s) device interface. The USB interface is the
recommended communication interface for high speed data transmission.
To properly connect the module’s USB interface to the host a USB 2.0 full speed compatible
connector is required. The HMS1 distribution contains the suitable USB driver to operate
HMS1 over USB. It is recommended to use this drive.
The USB host is responsible for supplying, across the VUSB_IN line, power to the module’s
USB interface, but not to other HMS1 interfaces. This is because HMS1 is designed as a
self-powered device compliant with the “Universal Serial Bus Specification Revision 1.1” (The
specification is ready for download on http://www.usb.org/developers/docs/).
HMS1_HD_V01.62
Page 21 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
3.8. Control Signals
Several control lines are signaling the states of the HMS1 module or control the module.
These states are power down, stand by, paging, GSM voice call, GSM data call, UMTS voice
call, UMTS data call or HSDPA connection.
3.8.1.PWR_IND Signal
PWR_IND notifies the on/off state of the module. High state of PWR_IND indicates that the
module is switched off. The state of PWR_IND immediately changes to low when IGT is
pulled low. For state detection an external pull-up resistor is required.
3.8.2.Status Signals
Two status signals (GREEN, BLUE) are provided for signaling the module’s connectivity
status:
•
•
•
When searching for a network the signal 1 (GREEN) alternates at 2Hz
When registered with a GSM network signal 1 is active
When registered with a WCDMA network signal 2 (BLUE) goes active, signal 1 inactive
HMS1_HD_V01.62
Page 22 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
4.
Antenna Interface
The RF interface has an impedance of 50Ω. HMS1 is capable of sustaining a total mismatch
at the antenna connector or pad without any damage, even when transmitting at maximum
RF power.
The external antenna must be matched properly to achieve best performance regarding
radiated power, DC-power consumption, modulation accuracy and harmonic suppression.
Antenna matching networks are not included on the HMS1 PCB and should be placed in the
host application.
The connection of the antenna or other equipment must be decoupled from DC voltage. This
is necessary because the antenna connector is DC coupled to ground via an inductor for
ESD protection.
4.1. Antenna Installation
To suit application requirements the HMS1 module adapts an internal antenna from Skycross
that is connected to the two antenna pads:
Figure 4: Internal antenna for HMS
4.1.1.Test Antenna
For production and type approval test the HMS1 module also provides a subminiature
coaxial switch from Hirose Ltd. The product name is:
MS-156NB
For detailed specifications and latest product information please contact your Hirose dealer
or visit the Hirose home page, for example http://www.hirose.com.
HMS1_HD_V01.62
Page 23 of 39
2006-08-21
s
HMS1 Hardware Interface Description
Confidential / Preliminary
5.
Electrical, Reliability and Radio Characteristics
5.1. Absolute Maximum Ratings
The absolute maximum ratings stated in Table 6 are stress ratings under any conditions.
Stresses beyond any of these limits will cause permanent damage to HMS1. The power
supply shall be compliant with the SELV safety standard defined in EN60950. The supply
current must be limited according to Table 6.
Table 6: Absolute maximum ratings
Parameter
Min
Max
Unit
Supply voltage BATT+
-0.3
+3.7
Voltage at digital pins in POWER DOWN mode
-0.3
+0.3
Voltage at digital pins in normal operation
-0.3
+3.0
Voltage at analog pins in POWER DOWN mode
-0.3
+0.3
Voltage at analog pins in normal operation
-0.3
+3.0
VUSB_IN
-0.3
+3.5
USB_DP, USB_DN
-0.3
+5.5
VDDLP
-0.3
+3.25
5.2. Operating Temperatures
Table 7: Ambient temperature according to IEC 60068-2 (without forced air circulation)
Parameter
Min
Typ
Max
Unit
Normal operation
+25
+55
°C
HMS1_HD_V01.62
Page 24 of 39
2006-08-21
s
HMS1 Hardware Interface Description
Confidential / Preliminary
5.3. Storage Conditions
The conditions stated below are only valid for modules in their original packed state in
weather protected, non-temperature-controlled storage locations. Normal storage time under
these conditions is 12 months maximum.
Table 8: Storage conditions
Type
Condition
Unit
Reference
Air temperature:
Low
High
-40
+85
°C
ETS 300 019-2-1: T1.2, IEC 68-2-1 Ab
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
Humidity relative:
Low
High
Condens.
10
90 at 30°C
90-100 at 30°C
--ETS 300 019-2-1: T1.2, IEC 68-2-56 Cb
ETS 300 019-2-1: T1.2, IEC 68-2-30 Db
Air pressure:
Low
High
70
106
kPa
IEC TR 60271-3-1: 1K4
IEC TR 60271-3-1: 1K4
Movement of surrounding air
1.0
m/s
IEC TR 60271-3-1: 1K4
Water: rain, dripping, icing and
frosting
Not allowed
---
---
Radiation:
1120
600
W/m
Solar
Heat
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
Chemically active substances
Not
recommended
IEC TR 60271-3-1: 1C1L
Mechanically active substances
Not
recommended
IEC TR 60271-3-1: 1S1
Vibration sinusoidal:
Displacement
Acceleration
Frequency range
IEC TR 60271-3-1: 1M2
1.5
2-9 9-200
mm
m/s
Hz
Shocks:
IEC 68-2-27 Ea
Shock spectrum
Duration
Acceleration
HMS1_HD_V01.62
semi-sinusoidal
ms
50
m/s
Page 25 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
5.4. Reliability Characteristics
Table 9: Summary of reliability test conditions
Type of test
Conditions
Standard
Vibration
Frequency range: 10-20Hz; acceleration:
3.1mm amplitude
Frequency range: 20-500Hz; acceleration:
5g
Duration: 2h per axis = 10 cycles; 3 axes
DIN IEC 68-2-6
Shock half-sinus
Acceleration: 500g
Shock duration: 1msec
1 shock per axis
6 positions (± x, y and z)
DIN IEC 68-2-27
Dry heat
Temperature: +70 ±2°C
Test duration: 16h
Humidity in the test chamber: < 50%
EN 60068-2-2 Bb
ETS 300 019-2-7
Temperature
change (shock)
Low temperature: -40°C ±2°C
High temperature: +85°C ±2°C
Changeover time: < 30s (dual chamber
system)
Test duration: 1h
Number of repetitions: 100
DIN IEC 68-2-14 Na
ETS 300 019-2-7
Damp heat cyclic High temperature: +55°C ±2°C
Low temperature: +25°C ±2°C
Humidity: 93% ±3%
Number of repetitions: 6
Test duration: 12h + 12h
DIN IEC 68-2-30 Db
Cold (constant
exposure)
DIN IEC 68-2-1
HMS1_HD_V01.62
Temperature: -40 ±2°C
Test duration: 16h
Page 26 of 39
ETS 300 019-2-5
2006-08-21
s
HMS1 Hardware Interface Description
Confidential / Preliminary
5.5. Pin Assignment and Signal Description
The board-to-board connector on HMS1 is an 80-pin double-row receptacle.
GND
GND
80
n.c.
n.c.
79
n.c.
PWR_IND
78
GND
n.c.
77
n.c.
n.c.
76
n.c.
n.c.
75
n.c.
GREEN
74
n.c.
BLUE
73
n.c.
n.c.
72
10
n.c.
n.c.
71
11
n.c.
n.c.
70
12
VUSB_IN
USB_DP
69
13
n.c.
n.c.
USB_DN
n.c.
68
14
15
n.c.
do not use
66
16
n.c.
n.c.
65
17
n.c.
n.c.
64
18
n.c.
n.c.
63
19
n.c.
n.c.
62
20
n.c.
n.c.
61
21
n.c.
60
22
GND
n.c.
n.c.
59
23
n.c.
n.c.
58
24
n.c.
do not use
57
67
25
n.c.
IGT
56
26
n.c.
EMERG_RST
55
27
n.c.
n.c.
54
28
n.c.
n.c.
53
29
n.c.
n.c.
52
30
n.c.
n.c.
51
31
n.c.
n.c.
50
32
n.c.
n.c.
49
33
VDDLP
n.c.
n.c.
48
n.c.
47
34
35
n.c.
VEXT
46
36
GND
BATT+
45
37
GND
BATT+
44
38
GND
BATT+
43
39
GND
BATT+
42
40
GND
BATT+
41
Figure 5: Pin assignments on board-to-board connector
HMS1_HD_V01.62
Page 27 of 39
2006-08-21
s
HMS1 Hardware Interface Description
Confidential / Preliminary
Table 10: Signal description
Function
Signal name
Power
supply
BATT+
IO
Signal form and level
Comment
VBATT = 3.6V±5%
Five pins of BATT+ and GND
must be connected in parallel
for supply purposes because
higher peak currents may
occur.
Minimum voltage must not fall
below 3.3V including drop,
ripple, spikes.
I ≈ 2A, during Tx burst (GSM)
n Tx = n x 577µs peak current every
4.616ms
Power
supply
GND
External
supply
voltage
VEXT
Ground
Application Ground
Normal mode:
VEXT may be used for
application circuits, for
example to supply power for
an SD card.
VOmin = 2.70V
VOtyp = 2.85V
VOmax = 3.00V
IOmax = Tbd.
If unused keep pin open.
The external digital logic must
not cause any spikes or
glitches on voltage VEXT.
Power
indicator
PWR_IND
VIHmax = Tbd.
VOLmax = Tbd. at Imax = Tbd.
PWR_IND (Power Indicator)
notifies the module’s on/off
state.
PWR_IND is an open
collector that needs to be
connected to an external pullup resistor. Low state of the
open collector indicates that
the module is on. Vice versa,
high level notifies the Powerdown mode.
Therefore, the pin may be
used to enable external
voltage regulators which
supply an external logic for
communication with the
module, e.g. level converters.
Ignition
IGT
Internal pull-up: RI ≈ 200kΩ
VILmax = Tbd. at Imax = Tbd.
VOHmax = Tbd.
~~~
~~~
ON
|____|
Active Low ≥ 400ms
(to be verified)
This signal switches on the
module.
This line must be driven low
by an open drain or open
collector driver.
Emergency
reset
EMERG_RST
Internal pull-up.
VILmax = 0.2V at Imax = -0.2mA
Reset in case of emergency.
Signal
HMS1_HD_V01.62
~~~
|______|
~~~
Pull down ≥ Tbd.
Page 28 of 39
This line must be driven low
by open drain or open
collector.
If unused keep pin open.
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
Function
Signal name
RTC backup
VDDLP
IO
Signal form and level
Comment
RI ≈ 1kΩ
If unused keep pin open.
VBATT+ = 0V:
VI = 1.5V…3.25V at Imax= Tbd.
USB
VUSB_IN
USB_DP
USB_DN
I/O
VINmin = 3.2V
VINmax = 3.5V
Differential Output Crossover voltage
Range
VCRSmin = 1.3V, VCRSmax = 2.0V
All electrical characteristics
according to USB
Implementers’ Forum, USB
1.1 Full Speed Specification.
Pullup at USB_DP Rtyp=1.5kOhm
HMS1_HD_V01.62
Page 29 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
Function
Signal name
IO
Signal form and level
Comment
Status
Indication
BLUE
GREEN
VOHmin = BATT+ - 0.2V
VOLmax = Tbd.
IOmax = Tbd.
Signals can be used to
control LEDs via driving
transistors.
BLUE: “0” = module has been
registered to an UMTS cell.
GREEN: “0” = module has
been registered to a GSM
cell.
Constantly changing between
“0” and “1” = module is in
“network search” state.
SIM
interface
specified for
use with 3V
SIM card
CCRST
RO ≈ 50Ω
VOLmax = 0.2V at I = 1mA
VOHmin = 2.7V at I = -1mA
VOHmax = 3.1V
All signals of SIM interface
are protected against ESD
with a special diode array.
CCIO
I/O
RI ≈ 10kΩ
VILmax = 1V
VILmin = -0.3V
VIHmin = 1.9V
VIHmax = 3.2V
VOLmax = 0.2V at I = 1mA
VOHmin = 2.7V at I = -1mA
VOHmax = 3.1V
SIM
interface
specified for
use with
1.8V SIM
card
CCCLK
RO ≈ 100Ω
VOLmax = 0.25V at I = 1mA
VOHmin = 2.65V at I = -1mA
VOHmax = 3.1V
CCVCC
VOmin = 2.9V
VOtyp = 3V
VOmax = 3.1V
IOmax = -50mA
CCRST
RO ≈ 50Ω
VOLmax = 0.2V at I = 1mA
VOHmin = 1.55V at I = -1mA
VOHmax = 1.85V
CCIO
I/O
RI ≈ 10kΩ
VILmax = 0.6V
VILmin = -0.3V
VIHmin = 1.15V
VIHmax = 1.85V
All signals of SIM interface
are protected against ESD
with a special diode array.
VOLmax = 0.2V at I = 1mA
VOHmin = 1.5V at I = -1mA
VOHmax = 1.85V
CCCLK
RO ≈ 100Ω
VOLmax = 0.25V at I = 1mA
VOHmin = 1.5V at I = -1mA
VOHmax = 1.85V
CCVCC
VOmin = 1.74V
VOtyp = 1.8V
VOmax = 1.86V
IOmax = -50mA
HMS1_HD_V01.62
Page 30 of 39
2006-08-21
s
HMS1 Hardware Interface Description
Confidential / Preliminary
5.6. Power Supply Ratings
Table 11: Power supply ratings
Parameter
Description
Conditions
Min
BATT+
Supply voltage
Directly measured at reference points
Tbd. BATT+ and GND.
Voltage must stay within the min/max
values, including voltage drop, ripple,
spikes.
-5%
Voltage drop during
transmit burst
Normal condition, power control level
for Pout max
Voltage ripple
Normal condition, power control level
for Pout max
@ f<200kHz
@ f>200kHz
IVDDLP
IBATT+
OFF State
supply current
Average standby
2)
supply current
HMS1_HD_V01.62
RTC Backup
@ BATT+ = 0V
Typ
3.6
Max
Unit
+5%
400
mV
50
mV
mV
Tbd.
µA
POWER DOWN mode
Tbd.
SLEEP mode
@ DRX = 9
Tbd.
mA
SLEEP mode
@ DRX = 5
Tbd.
mA
SLEEP mode
@ DRX = 2
Tbd.
mA
IDLE mode
@ DRX = 2
Tbd.
mA
Page 31 of 39
Tbd.
µA
2006-08-21
s
HMS1 Hardware Interface Description
Confidential / Preliminary
5.7. Air Interface
Test conditions: All measurements have been performed at Tamb= 25°C, VBATT+
reference points used on HMS1 are the BATT+ and GND contacts.
nom
= . The
Table 12: Air Interface GSM
Parameter
Min
Typ
Max
Unit
Frequency range
GSM 850
824
849
MHz
Uplink (MS → BTS)
E-GSM 900
880
915
MHz
GSM 1800
1710
1785
MHz
GSM 1900
1850
1910
MHz
Frequency range
GSM 850
869
894
MHz
Downlink (BTS → MS)
E-GSM 900
925
960
MHz
GSM 1800
1805
1880
MHz
GSM 1900
1930
1990
MHz
RF power @ ARP with 50Ω load
GSM 850
E-GSM 900
GSM 1800
GSM 1900
Number of channels
Duplex spacing
31
33
35
dBm
31
33
35
dBm
28
30
32
dBm
28
30
32
dBm
GSM 850
124
E-GSM 900
174
GSM 1800
374
GSM 1900
299
GSM 850
45
MHz
E-GSM 900
45
MHz
GSM 1800
95
MHz
GSM 1900
80
MHz
200
kHz
Carrier spacing
Multiplex, Duplex
TDMA / FDMA, FDD
Time slots per TDMA frame
Frame duration
4.615
ms
Time slot duration
577
µs
Modulation
Receiver input sensitivity @ ARP
BER Class II < 2.4% (static input level)
GMSK
GSM 850
-102
-105.5
dBm
E-GSM 900
-102
-105.5
dBm
GSM 1800
-102
-105.5
dBm
GSM 1900
-102
-105.5
dBm
Power control level PCL 5
Power control level PCL 0
HMS1_HD_V01.62
Page 32 of 39
2006-08-21
s
HMS1 Hardware Interface Description
Confidential / Preliminary
Table 13: Air Interface UMTS
Parameter
Frequency range
Min
Typ
Max
Unit
UMTS Band I
1920
1980
MHz
UMTS Band I
2110
2170
MHz
Max RF power @ ARP with 50Ω load
Power Class 3
UMTS Band I
21
25
dBm
Duplex spacing
UMTS Band I
Uplink (MS → BTS)
Frequency range
Downlink (BTS → MS)
Channel raster
Duplex
FDD
Receiver input sensitivity @ ARP
UMTS Band I
BER < 0,001 (static input level) DPCH_Ec
with 12,2 kbps reference channel
-117
HMS1_HD_V01.62
Page 33 of 39
24
190
MHz
200
kHz
dBm/3,84 Mhz
2006-08-21
s
HMS1 Hardware Interface Description
Confidential / Preliminary
5.8. Electrostatic Discharge
The HSDPA engine is not protected against Electrostatic Discharge (ESD) in general.
Consequently, it is subject to ESD handling precautions that typically apply to ESD sensitive
components. Proper ESD handling and packaging procedures must be applied throughout
the processing, handling and operation of any application that incorporates a HMS1 module.
Special ESD protection provided on HMS1:
•
Antenna interface: one discharge circuit
•
SIM interface: serial resistor, clamp diodes for protection against over voltage.
•
The remaining parts of HMS1 are not accessible to the user of the final product (since
they are installed within the device) and therefore, are only protected according to the
“Human Body Model” requirements.
HMS1 has been tested according to the EN 61000-4-2 standard. The measured values can
be gathered from the following table.
Table 14: Measured electrostatic values
Specification / Requirements
Contact discharge
Air discharge
ESD at SIM port
± 4kV
± 8kV
ESD at antenna port
± 4kV
± 8kV
ESD at 3.6V in, GND
± 4kV
± 8kV
CE ETS 300342-1 (June 1997)
Human Body Model (Test conditions: 1.5kΩ, 100pF)
ESD at SIM port
± 8kV
± 15kV
ESD at antenna port
± 8kV
± 15kV
ESD at 3.6V in, GND
± 8kV
± 15kV
Note: Please note that the values may vary with the individual application design. For
example, it matters whether or not the application platform is grounded over external
devices like a computer or other equipment, such as the Siemens reference
application described in Chapter 7.
HMS1_HD_V01.62
Page 34 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
6.
Mechanics
6.1. Mechanical Dimensions HMS1
The below figure shows the top view of HMS1 and provides an overview of the board's
mechanical dimensions.
Figure 6: HMS1 Top View (prelim.)
HMS1_HD_V01.62
Page 35 of 39
2006-08-21
s
HMS1 Hardware Interface Description
Confidential / Preliminary
Figure 7: HMS1 Dimensions (prelim.)
HMS1_HD_V01.62
Page 36 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
7.
Board-to-Board Application Connector
This chapter provides specifications and handling instructions for the 80 pin board-to-board
application interface connector used to connect the HMS1 module to the host device.
Table 15: Electrical and mechanical characteristics of the 80 pin board-to-board connector
Parameter
Specification (80-way connector)
Number of Contacts
80
Voltage
50V
Current Rating
0.5A max per contact
Resistance
0.05 Ohm per contact
Dielectric Withstanding Voltage
150V RMS AC for 1min
Operating Temperature
-40°C...+125°C
Contact Material
brass (CuZn)
Insulator Material
LCP (= Liquid Crystal Polymer), glass-filled, white
Maximum connection cycles
20 (@ 50mOhm max)
The mechanical dimensions of the 80 pin board-to-board connector are shown below (as an
extract from the datasheet):
Figure 8: Mechanical dimensions of 80 pin board-to-board connector
HMS1_HD_V01.62
Page 37 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
8.
Reference Approval
8.1. Reference Equipment for Type Approval
The Siemens reference setup submitted to type approve HMS1 consists of the following
components:
•
Siemens HMS1 cellular engine
•
Development Support Box DSB
•
SIM card reader integrated on the module
•
U.FL-R-SMT antenna connector and U.FL-LP antenna cable
•
PC as MMI
Figure 9: Reference equipment for Type Approval
HMS1_HD_V01.62
Page 38 of 39
2006-08-21
HMS1 Hardware Interface Description
Confidential / Preliminary
8.2. Compliance with FCC Rules and Regulations
The FCC Equipment Authorization Certification for the HMS1 reference application described
in Section 8.1 is listed under the
FCC identifier QIPHMS1
IC: 267W-HMS1
granted to Siemens AG.
The HMS1 reference application registered under the above identifier is certified to be in
accordance with the following Rules and Regulations of the Federal Communications
Commission (FCC).
Power listed is ERP for Part 22 and EIRP for Part 24
“This device contains GSM, GPRS Class10 and EGPRS Class 10 functions in the 900
and 1800MHz Band and the WCDMA function in the FDD1 Band (2100MHz) which are
not operational in U.S. Territories.
This device is to be used only for mobile and fixed applications. The antenna(s) used
for this transmitter must be installed to provide a separation distance of at least 20 cm
from all persons and must not be co-located or operating in conjunction with any other
antenna or transmitter. Users and installers must be provided with antenna installation
instructions and transmitter operating conditions for satisfying RF exposure compliance. Antennas used for this OEM module must not exceed 8.4dBi gain (GSM 1900)
and 2.9dBi (GSM 850) for mobile and fixed operating configurations. This device is
approved as a module to be installed in other devices.”
The FCC label of the module must be visible from the outside. If not, the host device is
required to bear a second label stating, “Contains FCC ID QIPHMS1”.
Manufacturers of mobile or fixed devices incorporating HMS1 modules are advised to include
instructions according to above mentioned RF exposure statements in their end product user
manual.
Please note that changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
If the final product is not approved for use in U.S. territories the application manufacturer
shall take care that the 850 MHz and 1900 MHz frequency bands be deactivated and that
band settings be inaccessible to end users. If these demands are not met (e.g. if the AT
interface is accessible to end users), it is the responsibility of the application manufacturer to
always ensure that the application be FCC approved regardless of the country it is marketed
in.
HMS1_HD_V01.62
Page 39 of 39
2006-08-21

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Mode                       : UseOutlines
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2006:08:21 09:11:13+02:00
Creator Tool                    : Acrobat PDFMaker 7.0.7 für Word
Modify Date                     : 2006:08:21 09:17:55+02:00
Metadata Date                   : 2006:08:21 09:17:55+02:00
Format                          : application/pdf
Title                           : HMS1 - Hardware Interface Description
Creator                         : pd36718
Document ID                     : uuid:ea11599a-5ed9-491e-a85f-05d660f53c14
Instance ID                     : uuid:36856d85-39ce-42eb-910d-8dea1e041b07
Tag Email Subject               : hms1_hw_interface_description-.doc
Tag Author Email Display Name   : Pfitzmann, Dieter
Tag Author Email                : dieter.pfitzmann@siemens.com
Tag Ad Hoc Review Cycle ID      : 385545700
Company                         : CNS Berlin, Siemens AG
Page Count                      : 39
Page Layout                     : OneColumn
Author                          : pd36718
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QIPHMS1

Navigation menu