THALES DIS AlS Deutschland MC55I-W Quadband GSM/GPRS Module User Manual hio
Gemalto M2M GmbH Quadband GSM/GPRS Module hio
08 user guide
MC55i-W Version: DocId: 01.301 MC55i-W_HIO_v01.301 Hardware Interface Overview MC55-W Hardware Interface Overview Document Name: MC55-W Hardware Interface Overview Version: 01.301 Date: 2011-3-8 DocId: MC55i-W_HIO_v01.301 Status Confidential / Released Supported Products: MC55i-W GENERAL NOTE THE USE OF THE PRODUCT INCLUDING THE SOFTWARE AND DOCUMENTATION (THE "PRODUCT") IS SUBJECT TO THE RELEASE NOTE PROVIDED TOGETHER WITH PRODUCT. IN ANY EVENT THE PROVISIONS OF THE RELEASE NOTE SHALL PREVAIL. THIS DOCUMENT CONTAINS INFORMATION ON CINTERION PRODUCTS. THE SPECIFICATIONS IN THIS DOCUMENT ARE SUBJECT TO CHANGE AT CINTERION'S DISCRETION. CINTERION WIRELESS MODULES GMBH GRANTS A NON-EXCLUSIVE RIGHT TO USE THE PRODUCT. THE RECIPIENT SHALL NOT TRANSFER, COPY, MODIFY, TRANSLATE, REVERSE ENGINEER, CREATE DERIVATIVE WORKS; DISASSEMBLE OR DECOMPILE THE PRODUCT OR OTHERWISE USE THE PRODUCT EXCEPT AS SPECIFICALLY AUTHORIZED. THE PRODUCT AND THIS DOCUMENT ARE PROVIDED ON AN "AS IS" BASIS ONLY AND MAY CONTAIN DEFICIENCIES OR INADEQUACIES. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, CINTERION WIRELESS MODULES GMBH DISCLAIMS ALL WARRANTIES AND LIABILITIES. THE RECIPIENT UNDERTAKES FOR AN UNLIMITED PERIOD OF TIME TO OBSERVE SECRECY REGARDING ANY INFORMATION AND DATA PROVIDED TO HIM IN THE CONTEXT OF THE DELIVERY OF THE PRODUCT. THIS GENERAL NOTE SHALL BE GOVERNED AND CONSTRUED ACCORDING TO GERMAN LAW. Copyright Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved. Copyright © 2011, Cinterion Wireless Modules GmbH Trademark Notice Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. All other registered trademarks or trademarks mentioned in this document are property of their respective owners. MC55i-W_HIO_v01.301 Confidential / Released Page 2 of 30 2011-3-8 MC55i-W Hardware Interface Overview Contents 30 Contents Introduction ................................................................................................................. 6 1.1 Related documents ............................................................................................ 6 1.2 Terms and Abbreviations ................................................................................... 7 1.3 Regulatory and Type Approval Information ..................................................... 10 1.3.1 Directives and Standards.................................................................... 10 1.3.2 SAR Requirements Specific to Portable Mobiles................................ 13 1.3.3 Safety Precautions.............................................................................. 14 Product Concept ....................................................................................................... 15 2.1 MC55i-W Key Features at a Glance ................................................................ 15 Application Interface................................................................................................. 17 3.1 Operating Modes ............................................................................................. 18 Antenna Interface...................................................................................................... 19 Electrical, Reliability and Radio Characteristics.................................................... 20 5.1 Absolute Maximum Ratings ............................................................................. 20 5.2 Operating Temperatures.................................................................................. 21 5.3 Storage Conditions .......................................................................................... 22 5.4 Reliability Characteristics ................................................................................. 23 5.5 Electrical Specifications of the Application Interface........................................ 24 5.6 Power Supply Ratings...................................................................................... 25 Mechanics.................................................................................................................. 26 6.1 Mechanical Dimensions of MC55i-W ............................................................... 26 6.2 Board-to-Board Connector............................................................................... 27 6.2.1 Mechanical Dimensions of the Hirose DF12 Connector ..................... 28 Reference Approval .................................................................................................. 29 7.1 Reference Equipment for Type Approval ......................................................... 29 7.2 Compliance with FCC Rules and Regulations ................................................. 30 MC55i-W_HIO_v01.301 Confidential / Released Page 3 of 30 2011-3-8 MC55i-W Hardware Interface Overview Tables 92 Tables Table 1: Table 2: Table 3: Table 4: Table 5: Table 6: Table 7: Table 8: Table 9: Table 10: Table 11: Table 12: Table 13: Table 14: Table 15: Table 16: Table 17: Directives ....................................................................................................... Standards of North American type approval .................................................. Standards of European type approval............................................................ Requirements of quality ................................................................................. Standards of the Ministry of Information Industry of the People’s Republic of China ............................................................................ Toxic or hazardous substances or elements with defined concentration limits Overview of operating modes ........................................................................ Return loss ..................................................................................................... Absolute maximum ratings............................................................................. Board temperature ......................................................................................... Ambient temperature according to IEC 60068-2 (w/o forced air circulation).. Ambient temperature with forced air circulation (air speed 0.9m/s) ............... Storage conditions ......................................................................................... Summary of reliability test conditions............................................................. Power supply ratings...................................................................................... Ordering information DF12 series .................................................................. Electrical and mechanical characteristics of the Hirose DF12C connector.... MC55i-W_HIO_v01.301 Confidential / Released Page 4 of 92 10 10 10 11 11 12 18 19 20 21 21 21 22 23 25 27 27 2011-3-8 MC55i-W Hardware Interface Overview Figures 92 Figures Figure 1: Figure 2: Figure 3: Figure 4: Figure 5: Figure 6: Pin assignment .............................................................................................. MC55i-W – top view ....................................................................................... Hirose DF12C receptacle on MC55i-W.......................................................... Header Hirose DF12 series............................................................................ Mechanical dimensions of Hirose DF12 connector........................................ Reference equipment for approval................................................................. MC55i-W_HIO_v01.301 Confidential / Released Page 5 of 92 24 26 27 27 28 29 2011-3-8 MC55i-W Hardware Interface Overview 1 Introduction 14 Introduction This document1 describes the hardware of the MC55i-W module that connects to the cellular device application and the air interface. It helps you quickly retrieve interface specifications, electrical and mechanical details and information on the requirements to be considered for integrating further components. 1.1 [1] [2] Related documents MC55i-W AT Command Set MC55i-W Release Notes Prior to using the MC55i-W modules or upgrading to a new firmware release, please carefully read the latest product information. For further information visit the Cinterion Wireless Modules Website: http://www.cinterion.com 1. The document is effective only if listed in the appropriate Release Notes as part of the technical documentation delivered with your Cinterion Wireless Modules product. MC55i-W_HIO_v01.301 Confidential / Released Page 6 of 30 2011-3-8 MC55i-W Hardware Interface Overview 1.2 Terms and Abbreviations 14 1.2 Terms and Abbreviations Abbreviation Description ADC Analog-to-Digital Converter AFC Automatic Frequency Control AGC Automatic Gain Control ANSI American National Standards Institute ARFCN Absolute Radio Frequency Channel Number ARP Antenna Reference Point ASC0 / ASC1 Asynchronous Serial Controller. Abbreviations used for first and second serial interface of MC55i-W ASIC Application Specific Integrated Circuit Thermistor Constant B2B Board-to-board connector BER Bit Error Rate BTS Base Transceiver Station CB or CBM Cell Broadcast Message CE Conformité Européene (European Conformity) CHAP Challenge Handshake Authentication Protocol CPU Central Processing Unit CS Coding Scheme CSD Circuit Switched Data CTS Clear to Send DAC Digital-to-Analog Converter DAI Digital Audio Interface dBm0 Digital level, 3.14dBm0 corresponds to full scale, see ITU G.711, A-law DCE Data Communication Equipment (typically modems, e.g. GSM module) DCS 1800 Digital Cellular System, also referred to as PCN DRX Discontinuous Reception DSB Development Support Box DSP Digital Signal Processor DSR Data Set Ready DTE Data Terminal Equipment (typically computer, terminal, printer or, for example, GSM application) DTR Data Terminal Ready DTX Discontinuous Transmission EFR Enhanced Full Rate EGSM Enhanced GSM MC55i-W_HIO_v01.301 Confidential / Released Page 7 of 30 2011-3-8 MC55i-W Hardware Interface Overview 1.2 Terms and Abbreviations 14 Abbreviation Description EMC Electromagnetic Compatibility ESD Electrostatic Discharge ETS European Telecommunication Standard FCC Federal Communications Commission (U.S.) FDMA Frequency Division Multiple Access FR Full Rate GMSK Gaussian Minimum Shift Keying GPRS General Packet Radio Service GSM Global Standard for Mobile Communications HiZ High Impedance HR Half Rate I/O Input/Output IC Integrated Circuit IMEI International Mobile Equipment Identity ISO International Standards Organization ITU International Telecommunications Union kbps kbits per second LED Light Emitting Diode Li-Ion Lithium-Ion Mbps Mbits per second MMI Man Machine Interface MO Mobile Originated MS Mobile Station (GSM module), also referred to as TE MSISDN Mobile Station International ISDN number MT Mobile Terminated MTTF Mean time to failure NTC Negative Temperature Coefficient OEM Original Equipment Manufacturer PA Power Amplifier PAP Password Authentication Protocol PBCCH Packet Switched Broadcast Control Channel PCB Printed Circuit Board PCL Power Control Level PCM Pulse Code Modulation PCN Personal Communications Network, also referred to as DCS 1800 PCS Personal Communication System, also referred to as GSM 1900 MC55i-W_HIO_v01.301 Confidential / Released Page 8 of 30 2011-3-8 MC55i-W Hardware Interface Overview 1.2 Terms and Abbreviations 14 Abbreviation Description PDU Protocol Data Unit PLL Phase Locked Loop PPP Point-to-point protocol PSU Power Supply Unit R&TTE Radio and Telecommunication Terminal Equipment RAM Random Access Memory RF Radio Frequency RMS Root Mean Square (value) ROM Read-only Memory RTC Real Time Clock Rx Receive Direction SAR Specific Absorption Rate SELV Safety Extra Low Voltage SIM card Subscriber Identification Module card; specifies a UICC with SIM application SMS Short Message Service SRAM Static Random Access Memory TA Terminal adapter (e.g. GSM module) TDMA Time Division Multiple Access TE Terminal Equipment, also referred to as DTE Tx Transmit Direction UART Universal asynchronous receiver-transmitter UICC USIM Integrated Circuit Card UMTS Universal Mobile Telecommunications System URC Unsolicited Result Code USIM UMTS Subscriber Identification Module USSD Unstructured Supplementary Service Data VSWR Voltage Standing Wave Ratio Phonebook abbreviations FD SIM fixdialing phonebook LD SIM last dialling phonebook (list of numbers most recently dialled) MC Mobile Equipment list of unanswered MT calls (missed calls) ME Mobile Equipment phonebook ON Own numbers (MSISDNs) stored on SIM or ME RC Mobile Equipment list of received calls SM SIM phonebook MC55i-W_HIO_v01.301 Confidential / Released Page 9 of 30 2011-3-8 MC55i-W Hardware Interface Overview 1.3 Regulatory and Type Approval Information 14 1.3 Regulatory and Type Approval Information 1.3.1 Directives and Standards MC55i-W has been designed to comply with the directives and standards listed below. It is the responsibility of the application manufacturer to ensure compliance of the final product with all provisions of the applicable directives and standards as well as with the technical specifications provided in the "MC55i-W Hardware Interface Description".2 Table 1: Directives 99/05/EC Directive of the European Parliament and of the council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (in short referred to as R&TTE Directive 1999/5/EC). The product is labeled with the CE conformity mark 2002/95/EC Directive of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) Table 2: Standards of North American type approval CFR Title 47 Code of Federal Regulations, Part 22 and Part 24 (Telecommunications, PCS); US Equipment Authorization FCC UL 60 950 Product Safety Certification (Safety requirements) NAPRD.03 V5.4 Overview of PCS Type certification review board Mobile Equipment Type Certification and IMEI control PCS Type Certification Review board (PTCRB) RSS132 (Issue2) RSS133 (Issue5) Canadian Standard Table 3: Standards of European type approval 3GPP TS 51.010-1 Digital cellular telecommunications system (Phase 2); Mobile Station (MS) conformance specification ETSI EN 301 511 V9.0.2 Candidate Harmonized European Standard (Telecommunications series) Global System for Mobile communications (GSM); Harmonized standard for mobile stations in the GSM 900 and DCS 1800 bands covering essential requirements under article 3.2 of the R&TTE directive (1999/5/EC) (GSM 13.11 version 7.0.1 Release 1998) GCF-CC V3.40 Global Certification Forum - Certification Criteria ETSI EN 301 489-1 V1.8.1 Candidate Harmonized European Standard (Telecommunications series) Electro Magnetic Compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common Technical Requirements 2. Manufacturers of applications which can be used in the US shall ensure that their applications have a PTCRB approval. For this purpose they can refer to the PTCRB approval of the respective module. MC55i-W_HIO_v01.301 Confidential / Released Page 10 of 30 2011-3-8 MC55i-W Hardware Interface Overview 1.3 Regulatory and Type Approval Information 14 Table 3: Standards of European type approval ETSI EN 301 489-7 V1.3.1 Candidate Harmonized European Standard (Telecommunications series) Electro Magnetic Compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS) EN 60950-1:2006 Safety of information technology equipment Table 4: Requirements of quality IEC 60068 Environmental testing DIN EN 60529 IP codes Table 5: Standards of the Ministry of Information Industry of the People’s Republic of China SJ/T 11363-2006 “Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products” (2006-06). SJ/T 11364-2006 “Marking for Control of Pollution Caused by Electronic Information Products” (2006-06). According to the “Chinese Administration on the Control of Pollution caused by Electronic Information Products” (ACPEIP) the EPUP, i.e., Environmental Protection Use Period, of this product is 20 years as per the symbol shown here, unless otherwise marked. The EPUP is valid only as long as the product is operated within the operating limits described in the Cinterion Wireless Modules Hardware Interface Description. Please see Table 6 for an overview of toxic or hazardous substances or elements that might be contained in product parts in concentrations above the limits defined by SJ/T 11363-2006. MC55i-W_HIO_v01.301 Confidential / Released Page 11 of 30 2011-3-8 MC55i-W Hardware Interface Overview 1.3 Regulatory and Type Approval Information 14 Table 6: Toxic or hazardous substances or elements with defined concentration limits MC55i-W_HIO_v01.301 Confidential / Released Page 12 of 30 2011-3-8 MC55i-W Hardware Interface Overview 1.3 Regulatory and Type Approval Information 14 1.3.2 SAR Requirements Specific to Portable Mobiles Mobile phones, PDAs or other portable transmitters and receivers incorporating a GSM module must be in accordance with the guidelines for human exposure to radio frequency energy. This requires the Specific Absorption Rate (SAR) of portable MC55i-W based applications to be evaluated and approved for compliance with national and/or international regulations. Since the SAR value varies significantly with the individual product design manufacturers are advised to submit their product for approval if designed for portable use. For European and US markets the relevant directives are mentioned below. It is the responsibility of the manufacturer of the final product to verify whether or not further standards, recommendations or directives are in force outside these areas. Products intended for sale on US markets ES 59005/ANSI C95.1 Considerations for evaluation of human exposure to Electromagnetic Fields (EMFs) from Mobile Telecommunication Equipment (MTE) in the frequency range 30MHz - 6GHz Products intended for sale on European markets EN 50360: MC55i-W_HIO_v01.301 Confidential / Released Product standard to demonstrate the compliance of mobile phones with the basic restrictions related to human exposure to electromagnetic fields (300MHz - 3GHz) Page 13 of 30 2011-3-8 MC55i-W Hardware Interface Overview 1.3 Regulatory and Type Approval Information 14 1.3.3 Safety Precautions The following safety precautions must be observed during all phases of the operation, usage, service or repair of any cellular terminal or mobile incorporating MC55i-W. Manufacturers of the cellular terminal are advised to convey the following safety information to users and operating personnel and to incorporate these guidelines into all manuals supplied with the product. Failure to comply with these precautions violates safety standards of design, manufacture and intended use of the product. Cinterion Wireless Modules GmbH assumes no liability for customer failure to comply with these precautions. When in a hospital or other health care facility, observe the restrictions on the use of mobiles. Switch the cellular terminal or mobile off, if instructed to do so by the guidelines posted in sensitive areas. Medical equipment may be sensitive to RF energy. The operation of cardiac pacemakers, other implanted medical equipment and hearing aids can be affected by interference from cellular terminals or mobiles placed close to the device. If in doubt about potential danger, contact the physician or the manufacturer of the device to verify that the equipment is properly shielded. Pacemaker patients are advised to keep their hand-held mobile away from the pacemaker, while it is on. Switch off the cellular terminal or mobile before boarding an aircraft. Make sure it cannot be switched on inadvertently. The operation of wireless appliances in an aircraft is forbidden to prevent interference with communications systems. Failure to observe these instructions may lead to the suspension or denial of cellular services to the offender, legal action, or both. Do not operate the cellular terminal or mobile in the presence of flammable gases or fumes. Switch off the cellular terminal when you are near petrol stations, fuel depots, chemical plants or where blasting operations are in progress. Operation of any electrical equipment in potentially explosive atmospheres can constitute a safety hazard. Your cellular terminal or mobile receives and transmits radio frequency energy while switched on. Remember that interference can occur if it is used close to TV sets, radios, computers or inadequately shielded equipment. Follow any special regulations and always switch off the cellular terminal or mobile wherever forbidden, or when you suspect that it may cause interference or danger. Road safety comes first! Do not use a hand-held cellular terminal or mobile when driving a vehicle, unless it is securely mounted in a holder for handsfree operation. Before making a call with a hand-held terminal or mobile, park the vehicle. Handsfree devices must be installed by qualified personnel. Faulty installation or operation can constitute a safety hazard. SOS IMPORTANT! Cellular terminals or mobiles operate using radio signals and cellular networks. Because of this, connection cannot be guaranteed at all times under all conditions. Therefore, you should never rely solely upon any wireless device for essential communications, for example emergency calls. Remember, in order to make or receive calls, the cellular terminal or mobile must be switched on and in a service area with adequate cellular signal strength. Some networks do not allow for emergency calls if certain network services or phone features are in use (e.g. lock functions, fixed dialling etc.). You may need to deactivate those features before you can make an emergency call. Some networks require that a valid SIM card be properly inserted in the cellular terminal or mobile. MC55i-W_HIO_v01.301 Confidential / Released Page 14 of 30 2011-3-8 MC55i-W Hardware Interface Overview 2 Product Concept 16 Product Concept 2.1 MC55i-W Key Features at a Glance Feature Implementation General Frequency bands Quad band: GSM 850/900/1800/1900MHz GSM class Small MS Output power (according to Release 99, V5) Class 4 (+33dBm ±2dB) for EGSM850 Class 4 (+33dBm ±2dB) for EGSM900 Class 1 (+30dBm ±2dB) for GSM1800 Class 1 (+30dBm ±2dB) for GSM1900 Power supply 3.3V < VBATT+ < 4.8V Operating temperature (board temperature) Normal operation: -30°C to +85°C Restricted operation: -40°C to -30°C and +85°C to +90°C Physical Dimensions: 32.5mm x 35mm x max. 3.1mm Weight: approx. 6g RoHS All hardware components fully compliant with EU RoHS Directive GSM / GPRS features Data transfer GPRS: • Multislot Class 10 • Full PBCCH support • Mobile Station Class B • Coding Scheme 1 – 4 CSD: • V.110, RLP, non-transparent • 2.4, 4.8, 9.6, 14.4kbps • USSD PPP-stack for GPRS data transfer SMS Point-to-point MT and MO Cell broadcast Text and PDU mode Storage: SIM card plus 25 SMS locations in mobile equipment Transmission of SMS alternatively over CSD or GPRS. Preferred mode can be user defined. Fax Group 3; Class 2 Audio Speech codecs: • Half Rate (ETS 06.20) • Full Rate (ETS 06.10) • Enhanced Full Rate (ETS 06.50 / 06.60 / 06.80) • Adaptive Multi Rate AMR Handsfree operation, echo cancellation, noise reduction, 7 different ringing tones / melodies MC55i-W_HIO_v01.301 Confidential / Released Page 15 of 30 2011-3-8 MC55i-W Hardware Interface Overview 2.1 MC55i-W Key Features at a Glance 16 Feature Implementation Software AT commands Hayes 3GPP TS 27.007, TS 27.005, Cinterion Wireless Modules AT commands for RIL compatibility SIM Application Toolkit Supports SAT class 3, GSM 11.14 Release 99, support of letter class “c” TCP/IP stack Protocols: TCP, UDP, HTTP, FTP, SMTP, POP3 Access by AT commands Firmware update Windows executable for update over serial interface ASC0 Interfaces 2 serial interfaces ASC0: • 8-wire modem interface with status and control lines, unbalanced, asynchronous • Fixed bit rates: 300bps to 230,000bps • Autobauding: 1,200bps to 230,000bps • Supports RTS0/CTS0 hardware handshake and software XON/XOFF flow control. • Multiplex ability according to GSM 07.10 Multiplexer Protocol. ASC1: • 4-wire, unbalanced asynchronous interface • Fixed bit rates: 300bps to 230,000bps • Supports RTS1/CTS1 hardware handshake and software XON/XOFF flow control Audio 1 analog interface 1 digital interface (PCM) SIM interface Supported SIM cards: 3V, 1.8V External SIM card reader has to be connected via interface connector (note that card reader is not part of MC55i-W) Antenna 50. External antenna can be connected via antenna connector or solderable pad. Module interface 50-pin board-to-board connector Power on/off, Reset Power on/off Switch-on by hardware pin IGT Switch-off by AT command (AT^SMSO) Automatic switch-off in case of critical temperature and voltage conditions Reset Orderly shutdown and reset by AT command Special features Real time clock Timer functions via AT commands Phonebook SIM and phone TTY/CTM support Integrated CTM modem Evaluation kit DSB75 MC55i-W_HIO_v01.301 Confidential / Released DSB75 Evaluation board designed to test and type approve Cinterion Wireless Module and provide a sample configuration for application engineering. A special adapter is required to connect the module to the DSB75. Page 16 of 30 2011-3-8 MC55i-W Hardware Interface Overview 3 Application Interface 18 Application Interface MC55i-W is equipped with a 50-pin board-to-board connector that connects to the external application. The host interface incorporates several sub-interfaces: power supply, SIM interface, serial interface ASC0, serial interface ASC1, analog audio interface, and DAI/PCM interface (for details see Chapter 2 and Section 5.5). MC55i-W_HIO_v01.301 Confidential / Released Page 17 of 30 2011-3-8 MC55i-W Hardware Interface Overview 3.1 Operating Modes 18 3.1 Operating Modes The table below briefly summarizes the various operating modes referred to in the following sections. Table 7: Overview of operating modes Mode Function Normal operation GSM / GPRS SLEEP Various powersave modes set with AT+CFUN command. Software is active to minimum extent. If the module was registered to the GSM network in IDLE mode, it is registered and paging with the BTS in SLEEP mode, too. Power saving can be chosen at different levels: The NON-CYCLIC SLEEP mode (AT+CFUN=0) disables the AT interface. The CYCLIC SLEEP modes AT+CFUN= 7 and 9 alternatingly activate and deactivate the AT interfaces to allow permanent access to all AT commands. GSM IDLE Software is active. Once registered to the GSM network, paging with BTS is carried out. The module is ready to send and receive. GSM TALK Connection between two subscribers is in progress. Power consumption depends on network coverage individual settings, such as DTX off/on, FR/EFR/HR, hopping sequences, antenna. GPRS IDLE Module is ready for GPRS data transfer, but no data is currently sent or received. Power consumption depends on network settings and GPRS configuration (e.g. multislot settings). GPRS DATA GPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates and GPRS configuration (e.g. used multislot settings). Power Down Normal shutdown after sending the AT^SMSO command. Only a voltage regulator is active for powering the RTC. Software is not active. Interfaces are not accessible. Operating voltage (connected to BATT+) remains applied. Alarm mode Restricted operation launched by RTC alert function while the module is in Power Down mode. Module will not be registered to GSM network. Limited number of AT commands is accessible. MC55i-W_HIO_v01.301 Confidential / Released Page 18 of 30 2011-3-8 MC55i-W Hardware Interface Overview 4 Antenna Interface 19 Antenna Interface The RF interface has an impedance of 50. MC55i-W is capable of sustaining a total mismatch at the antenna connector or pad without any damage, even when transmitting at maximum RF power. The external antenna must be matched properly to achieve best performance regarding radiated power, DC-power consumption and harmonic suppression. Matching networks are not included on the MC55i-W PCB and should be placed in the host application. Regarding the return loss MC55i-W provides the following values: Table 8: Return loss State of module Return loss of module Recommended return loss of application Receive > 8dB > 12dB Transmit not applicable > 12dB Idle < 5dB not applicable The connection of the antenna or other equipment must be decoupled from DC voltage. This is necessary because the antenna connector is DC coupled to ground via an inductor for ESD protection. MC55i-W_HIO_v01.301 Confidential / Released Page 19 of 30 2011-3-8 MC55i-W Hardware Interface Overview 5 Electrical, Reliability and Radio Characteristics 25 Electrical, Reliability and Radio Characteristics 5.1 Absolute Maximum Ratings Absolute maximum ratings for supply voltage and voltages on digital and analog pins of MC55iW are listed in Table 9. Exceeding these values will cause permanent damage to MC55i-W. Table 9: Absolute maximum ratings Parameter Min Max Unit Supply voltage BATT+ -0.3 +6.0 Voltage at digital pins in normal operation -0.3 +3.3 Voltage at all digital pins in Power Down mode -0.3 +0.3 Voltage at SIM interface, CCVCC 1.8V in normal Operation -0.3 +2.2 Voltage at SIM interface, CCVCC 2.85V in normal Operation -0.3 +3.3 Voltage at analogue pins in normal operation -0.3 +3.0 Voltage at analogue pins in Power Down mode -0.3 +0.3 VDDLP -0.3 +2.5 MC55i-W_HIO_v01.301 Confidential / Released Page 20 of 30 2011-3-8 MC55i-W Hardware Interface Overview 5.2 Operating Temperatures 25 5.2 Operating Temperatures Please note that the module’s lifetime, i.e., the MTTF (mean time to failure) may be reduced, if operated outside the restriced temperature range. A special URC reports whether the module enters or leaves the restriced temperature range (see [1]; AT^SCTM). Table 10: Board temperature Parameter Min Typ Max Unit Normal operation -30 +25 +85 °C Restricted operation -40 to -30 +85 to +90 °C Automatic shutdown Temperature measured on MC55i-W board 1. <-40 --- >+90 °C Due to temperature measurement uncertainty, a tolerance of ±3°C on the thresholds may occur. Table 11: Ambient temperature according to IEC 60068-2 (w/o forced air circulation) Parameter Min GSM Call @ max. RF-Power Typ Max Unit -40 +75 °C GPRS Class 8 @ max. RF-Power -40 +75 °C GPRS Class 10 @ max. RF-Power (quad band only) -40 +60 °C Max Unit Table 12: Ambient temperature with forced air circulation (air speed 0.9m/s) Parameter Min Typ GSM Call @ max. RF-Power -40 +80 °C GPRS Class 8 @ max. RF-Power -40 +80 °C GPRS Class 10 @ max. RF-Power (quad band only) -40 +70 °C Note that within the specified operating temperature ranges the board temperature may vary to a great extent depending on operating mode, used frequency band, radio output power and current supply voltage. When data are transmitted over GPRS the quad band module variant automatically reverts to a lower Multislot Class if the temperature rises to the limit specified for normal operation and, vice versa, returns to the higher Multislot Class if the temperature is back to normal. MC55i-W_HIO_v01.301 Confidential / Released Page 21 of 30 2011-3-8 MC55i-W Hardware Interface Overview 5.3 Storage Conditions 25 5.3 Storage Conditions The conditions stated below are only valid for modules in their original packed state in weather protected, non-temperature-controlled storage locations. Normal storage time under these conditions is 12 months maximum. Table 13: Storage conditions Type Condition Unit Reference Air temperature: Low High -40 +85 °C ETS 300 019-2-1: T1.2, IEC 60068-2-1 Ab ETS 300 019-2-1: T1.2, IEC 60068-2-2 Bb Humidity relative: Low High Condens. 10 90 at 30°C 90-100 at 30°C Air pressure: Low High 70 106 kPa IEC TR 60271-3-1: 1K4 IEC TR 60271-3-1: 1K4 Movement of surrounding air 1.0 m/s IEC TR 60271-3-1: 1K4 Water: rain, dripping, icing and frosting Not allowed --- --- Radiation: Solar Heat W/m2 ETS 300 019-2-1: T1.2, IEC 60068-2-2 Bb ETS 300 019-2-1: T1.2, IEC 60068-2-2 Bb Chemically active substances 1120 600 Not recommended IEC TR 60271-3-1: 1C1L Mechanically active substances Not recommended IEC TR 60271-3-1: 1S1 Vibration sinusoidal: Displacement Acceleration Frequency range 1.5 2-9 9-200 mm m/s2 Hz Shocks: Shock spectrum Duration Acceleration semi-sinusoidal 50 ms m/s2 MC55i-W_HIO_v01.301 Confidential / Released --ETS 300 019-2-1: T1.2, IEC 60068-2-56 Cb ETS 300 019-2-1: T1.2, IEC 60068-2-30 Db IEC TR 60271-3-1: 1M2 IEC 60068-2-27 Ea Page 22 of 30 2011-3-8 MC55i-W Hardware Interface Overview 5.4 Reliability Characteristics 25 5.4 Reliability Characteristics The test conditions stated below are an extract of the complete test specifications. Table 14: Summary of reliability test conditions Type of test Conditions Standard Vibration Frequency range: 10-20 Hz; acceleration: 3.1mm amplitude Frequency range: 20-500 Hz; acceleration: 5g Duration: 2h per axis = 10 cycles; 3 axes DIN IEC 60068-2-6 Shock half-sinus Acceleration: 500g Shock duration: 1msec 1 shock per axis 6 positions (± x, y and z) DIN IEC 60068-2-27 Dry heat Temperature: +70 ±2°C Test duration: 16 h Humidity in the test chamber: < 50% EN 60068-2-2 Bb ETS 300019-2-7 Temperature change (shock) Low temperature: -40°C ±2°C High temperature: +85°C ±2°C Changeover time: < 30s (dual chamber system) Test duration: 1 h Number of repetitions: 100 DIN IEC 60068-2-14 Na High temperature: +55°C ±2°C Low temperature: +25°C ±2°C Humidity: 93% ±3% Number of repetitions: 6 Test duration: 12h + 12h DIN IEC 60068-2-30 Db Temperature: -40 ±2°C Test duration: 16 h DIN IEC 60068-2-1 Damp heat cyclic Cold (constant exposure) MC55i-W_HIO_v01.301 Confidential / Released Page 23 of 30 ETS 300019-2-7 ETS 300019-2-5 2011-3-8 MC55i-W Hardware Interface Overview 5.5 Electrical Specifications of the Application Interface 25 5.5 Electrical Specifications of the Application Interface The Hirose DF12C board-to-board connector on MC55i-W is a 50-pin double-row receptacle. The names and the positions of the pins can be seen from Figure 2 which shows the top view of MC55i-W. CCCLK Not connected 50 CCVCC Not connected 49 CCIO EPP 48 CCRST EPN 47 CCIN VMICN 46 CCGND VMICP 45 RXDDAI MICP 44 TFSDAI MICN 43 SCLK AGND 42 10 TXDDAI IGT 41 11 RFSDAI EMERG_RST 40 12 Do not use DCD0 39 13 STATUS CTS1 38 14 RXD1 CTS0 37 15 RXD0 RTS1 36 16 TXD1 DTR0 35 17 TXD0 RTS0 34 18 VDDLP DSR0 33 19 Not connected RING0 32 20 Not connected VDD 31 21 GND BATT+ 30 22 GND BATT+ 29 23 GND BATT+ 28 24 GND BATT+ 27 25 GND BATT+ 26 Figure 1: Pin assignment MC55i-W_HIO_v01.301 Confidential / Released Page 24 of 30 2011-3-8 MC55i-W Hardware Interface Overview 5.6 Power Supply Ratings 25 5.6 Power Supply Ratings Table 15: Power supply ratings BATT+ Description Conditions Min Typ Max Unit Supply voltage Directly measured at module. Voltage must stay within the min/ max values, including voltage drop, ripple and spikes. 3.3 4.0 4.8 Maximum allowed voltage drop during transmit burst Normal condition, power control level for Pout max 400 mV Voltage ripple Normal condition, power control level for Pout max @ f<250kHz @ f>250kHz mVpp 105 30 IVDDLP OFF state supply current RTC backup @ BATT+ = 0V 6.0 µA IBATT+1 OFF state supply current POWER DOWN mode 45 µA Average supply current SLEEP mode2 @ DRX = 9 1.3 mA 1.6 mA 2.2 mA IDLE mode @ DRX = 2 9.5 mA Voice call GSM850/900, PCL=5 180 mA GPRS data transfer GSM850/900 PCL=5, (1Tx/ 4Rx) 170 mA GPRS data transfer GSM850/900 PCL=5, (2Tx/ 3Rx) 310 mA Voice call GSM1800/1900, PCL=0 135 mA GPRS data transfer GSM1800/1900 PCL=0, (1Tx/ 4Rx) 130 mA GPRS data transfer GSM1800/1900 PCL=0, (2Tx/ 3Rx) 230 mA Voice call GSM850, PCL=5 1.35 1.383 SLEEP mode @ DRX = 5 SLEEP mode @ DRX = 2 1. 2. 3. Peak current during Voice call GSM900, PCL=5 GSM transmission Voice call GSM1800, PCL=0 burst 1.30 1.353 0.95 0.98 Voice call GSM1900, PCL=0 0.89 0.923 With an impedance of ZLOAD=50Ohm at the antenna connector. ASC0, ASC1 inactive Measurements start 6 minutes after switching on the module, Averaging times: SLEEP mode - 3 minutes; transfer modes - 1.5 minutes, Communication tester settings: no neighbour cells, no cell reselection etc., RMC (Reference Measurement Channel) At total mismatch. MC55i-W_HIO_v01.301 Confidential / Released Page 25 of 30 2011-3-8 MC55i-W Hardware Interface Overview 6 Mechanics 28 Mechanics The following sections describe the mechanical dimensions of MC55i-W and give recommendations for integrating MC55i-W into the host application. 6.1 Mechanical Dimensions of MC55i-W Figure 2 shows the top view on MC55i-W and provides an overview of the mechanical dimensions of the board. Length: Width: Height: 35mm 32.5mm 3.1mm (including board-to-board connector), 2.9mm (excluding connector) Weight: 6g Pin 1 Pin 50 Figure 2: MC55i-W – top view MC55i-W_HIO_v01.301 Confidential / Released Page 26 of 30 2011-3-8 MC55i-W Hardware Interface Overview 6.2 Board-to-Board Connector 28 6.2 Board-to-Board Connector This section provides specifications for the 50-pin board-to-board connector which serves as physical interface to the host application. The receptacle assembled on the MC55i-W PCB is type Hirose DF12C. Mating headers from Hirose are available in different stacking heights. Figure 3: Hirose DF12C receptacle on MC55i-W Figure 4: Header Hirose DF12 series Table 16: Ordering information DF12 series Item Part number Stacking height (mm) HRS number Receptacle on MC55i-W DF12C(3.0)-50DS-0.5V(81) 3-5 537-0694-9-81 Headers DF12 series DF12E(3.0)-50DP-0.5V(81) DF12E(3.5)-50DP-0.5V(81) DF12E(4.0)-50DP-0.5V(81) DF12E(5.0)-50DP-0.5V(81) 3.0 3.5 4.0 5.0 537-0834-6-** 537-0534-2-** 537-0559-3-** 537-0584-0-** Note: The headers listed above are without boss and metal fitting. Please contact Hirose for details on other types of mating headers. Asterixed HRS numbers denote different types of packaging. Table 17: Electrical and mechanical characteristics of the Hirose DF12C connector Parameter Specification (50 pin board-to-board connector) Number of contacts 50 Quantity delivered 2000 connectors per tape & reel Voltage 50V Rated current 0.3A max per contact Resistance 0.05 per contact Dielectric withstanding voltage 500V RMS min Operating temperature -45°C...+125°C Contact material phosphor bronze (surface: gold plated) Insulator material PA , beige natural Stacking height 3.0 mm ; 3.5 mm ; 4.0 mm ; 5.0 mm Insertion force 21.8N Withdrawal force 1st Withdrawal force 50 10N th Maximum connection cycles MC55i-W_HIO_v01.301 Confidential / Released 10N 50 Page 27 of 30 2011-3-8 MC55i-W Hardware Interface Overview 6.2 Board-to-Board Connector 28 6.2.1 Mechanical Dimensions of the Hirose DF12 Connector Figure 5: Mechanical dimensions of Hirose DF12 connector MC55i-W_HIO_v01.301 Confidential / Released Page 28 of 30 2011-3-8 MC55i-W Hardware Interface Overview 7 Reference Approval 30 Reference Approval 7.1 Reference Equipment for Type Approval The Cinterion Wireless Modules reference setup submitted to type approve MC55i-W consists of the following components: Antenna GSM / GPRS / UMTS Base Station GSM Antenna with 1m cable ASC0 PC ASC1 SMA Module DSB75 Power supply SIM Card Audio Module Module extern with flexible cable and 50-to-80 adapter to DSB75 Handset Audio Test System Figure 6: Reference equipment for approval MC55i-W_HIO_v01.301 Confidential / Released Page 29 of 30 2011-3-8 MC55i-W Hardware Interface Overview 7.2 Compliance with FCC Rules and Regulations 30 7.2 Compliance with FCC Rules and Regulations The Equipment Authorization Certification for the Cinterion Wireless Modules reference application described in Section 7.1 will be registered under the following identifiers: FCC Identifier: QIPMC55I-W Industry Canada Certification Number: 7830A-MC55IW Granted to Cinterion Wireless Modules GmbH Manufacturers of mobile or fixed devices incorporating MC55i-W modules are authorized to use the FCC Grants and Industry Canada Certificates of the MC55i-W modules for their own final products according to the conditions referenced in these documents. In this case, the FCC label of the module shall be visible from the outside, or the host device shall bear a second label stating "Contains FCC ID QIPMC55I-W", and accordingly "Contains IC 7830A-MC55IW". IMPORTANT: Manufacturers of portable applications incorporating MC55i-W modules are required to have their final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable mobile. This is mandatory to meet the SAR requirements for portable mobiles (see Section 1.3.2 for detail). Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. MC55i-W_HIO_v01.301 Confidential / Released Page 30 of 30 2011-3-8
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : ctna0151 Create Date : 2011:03:08 11:22:19Z Modify Date : 2011:03:08 12:07:15+01:00 XMP Toolkit : Adobe XMP Core 4.2.2-c063 53.352624, 2008/07/30-18:12:18 Creator Tool : FrameMaker 9.0 Metadata Date : 2011:03:08 12:07:15+01:00 Format : application/pdf Title : hio.book Creator : ctna0151 Producer : Acrobat Distiller 9.4.2 (Windows) Document ID : uuid:c4eccd30-508b-4051-85d0-b4d7baec3b34 Instance ID : uuid:a36b7f7e-fa57-48c0-a28b-8e04fbf2ea6a Page Mode : UseOutlines Page Count : 30EXIF Metadata provided by EXIF.tools