TRANE Package Units(both Units Combined) Manual L0905299
User Manual: TRANE TRANE Package Units(both units combined) Manual TRANE Package Units(both units combined) Owner's Manual, TRANE Package Units(both units combined) installation guides
Open the PDF directly: View PDF .
Page Count: 20
Download | |
Open PDF In Browser | View PDF |
WCX-IOM-1D 18-BB33D7-5 I TALLATIO OPERATION INT CE ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES WCX048G1,3,4 WCX060G1,3,4 Single Package Heat Pump 12 SEER Convertible BAYLIFT002AA LIFTING LUG KIT 2 Model: WCX024G1 WCX030GI WCX036G 1,3,4 WCX042G 1,3 IMPORTANT--This Document is customer propertyand " 5 TOn is to remain with this unit. Please return to service information pack upon completion of work. NOTICE Warnings and Cautions appear at appropriate locations throughout this manual. Read these carefully. _WARNING: Indicates a potentially ardous situation which, if not avoided, SAVINGTHEEARTH. SAVINGYOURMONEY. Since The Trane Companyhas a policy of continuous product and product data improvement, it reserves the right to change design and specification without notice. © 2002 American Standard Inc. All rights reserved could result in death or serious injury. ,_CAUTION" All phases d this installation must comply with the NATIONAL, STATE & LOCAL CODES, In the absence of local codes, the installation must conform with National Electric Code -- ANSI/ NFPA 70 or "LATEST REVISION." haz- Indicates a potentially ardous situation which, if not avoided, hazmay result in minor or moderate injury. It may also be used to alert against unsafe practices and where property=damage=only accidents could occur. o7/o2 GENERAL IMPORTANT: Read this entire manual before beginning lation procedures. INFORMATION instal- SAFETY NOTICE• THIS INFORMATION IS INTENDED FOR USE BY INDIVIDUALS POSSESSING ADEQUATE BACKGROUNDS OF ELECTRICAL AND MECHANICAL EXPERIENCE. ANY ATTEMPT TO REPAIR A CENTRAL AIR CONDITIONING PRODUCT MAY RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE. THE MANUFACTURER OR SELLER CANNOT BE RESPONSIBLE FOR THE INTERPRETATION OF THIS INFORMATION, NOR CAN IT ASSUME LIABILITY IN CONNECTION WITH ITS USE• Read this manual carefully before attempting to install, operate, or perform maintenance on this unit. Installation and maintenance should be performed by qualified service technicians only. NOTE: "Warnings" and "Cautions" appear at appropriate places in this manual Your personal safety and the proper operation of this air conditioning product require that you follow them carefully. The manufacturer assumes no liability for installations or servicing performed by unqualified personnel. INSPECTION 1. Check for damage after the unit is unloaded. Report promptly, to the carrier, any damage found to the unit. Do not drop the unit. IMPORTANT: RECONNECT ALL GROUNDING DEVICES• ALL PARTS OF THIS PRODUCT CAPABLE OF CONDUCTING ELECTICAL CURRENT ARE GROUNDED. IF GROUNDING WIRES, SCREWS, STRAPS, CLIPS NUTS OR WASHERS USED TO COMPLETE A PATH TO GROUND ARE REMOVED FOR SERVICE. THEY MUST BE RETURNED TO THIER ORIGINAL POSITION AND PROPERLY FASTENED. IMPORTANT: ALL POWER LEGS MAY NOT BE BROKEN BY CONTACTORS. SEE WIRING DIAGRAM ON UNIT CONTROL BOX COVER. BEFORE STARTING THE COMPRESSOR, THE CRANKCASE HEATER SHOULD BE ENERGIZED FOR EIGHT HOURS © TYPICAL ROOFTOP INSTALLATION (WCX024=060G 3 IMPORTANT: The( to useprevent of"spreader bars" is required when hoisting the unit damage to sides and top ). 2. Check the unit's nameplate to determine if the unit is correct for the intended application. The power supply must be adequate for both the unit and all accessories. 3. Check to be sure the refrigerant charge has been retained during shipment. Access to 1/4" flare pressure taps may be gained by removing the furnace compartment access panel. WITH FULL PERIMETER CURBS Models) FIELD SUPPLIED SUPPORTS AT EACH END OF CURB FIELD SUPPLIED CANT STRIP ROOF FIELD SUPPLIED RIGIDINBULATION ROOF SUPPLY AIR DUCT Page 2 i | RETURN AIR DUCT MOUNTING CURB @ TYPICAL ROOFTOP SEE NOTE iNSTALLATiON (WCX024-060G WiTH BAYCURB030A,038A IVlodels) 1 SEE NOTE2 FIELD SUPPLIED SUPPORTS ATEACH END OFCURB ROOFING ._ROOFINSULATION FIELD SUPPLIED CANTSTRIP ROOF FIELD SUPPLIED NOTE 1: The WCX036-042 Models extend out ROOF past this end of the curb only. ) SUPPLY AIR DUCT NOTE 2: Only the WCX048, 060G Models extend past both the end and the side of the curb as illustrated ® CONVERTING HORIZONTAL MOUNTING CURB RETURN AiR DUCT TO DOWNFLOW o NOTE SUPPLY SHEET METAL SCREWS HORIZONTAL SUPPLY AIR COVER HORIZONTAL RETURN AIR COVER OPENING 1. REMOVE THE SCREW NEAREST TO THE OPENING AND PULL THE PANEL FIRMLY TOWARD THE OUTSIDE OF THE UNIT TO DISENGAGE THE BACK ATTACHMENT RETURN OPENING 2. REMOVE RIGHT HAND SCREW AND MOVE PANEL TO THE RIGHT OR REMOVE BOTH SCREWS Page 3 DiMENSiONAL @ _ W_X024-060G DATA OUTLINE _r_ = BACK A EVAPORA[OR CO I L & _owER _ANE_ SUPPLY \\ 1 ......... APP/ ARANC_ [! .52} _r_ (}ROSS S]CIION CORNER WEIGHT W1 W2 W3 r_ / I RETURN PER METER FLANGES (LBS) W4 UNIT WEIGHT WCX024G 79 74 74 104 331 WCX030G 82 64 86 110 342 WCX036G 110 82 88 118 398 WCX042G 110 82 88 118 398 WCX048G 149 104 117 134 504 WCX060G 149 104 117 134 504 A B C D E F G H 56-1/2 36 29-3/16 18-9/16 11-1/16 6-9/16 6-13/16 17 64 Page 4 "_'_'-.'.,,,. / ..................................................... ....... I __ YPICA[ MODEL < <_- 65-1/4 36 45 29-1/16 33-3/8 18-9/16 21-1/16 11-1/16 15-1/16 6-9/16 4-15/16 11-1/8 9-1/8 J K 21 25-3/8 21 24-3/8 19-1/4 27-1/2 19-1/4 27-1/2 24-1/4 28-1/2 24-1/4 28-1/2 17 21-15/1_ L M N P 17-1/2 10 3 4-7/16 17-1/2 10 3 8-3/4 20 14 3-1/2 8-5/16 DiMENSiONAL WCX024=060G CONTRO. ACC SS DATA OUTLINE = FRONT BOX _AN£L _C©NDENSER & \ ELECTRIC ACCESS COIL GUARD HEAIER PANEL D66Y982 RECOMMENDED CLEARANCE TO COMBUSTIBLE MATERIAL BOTTOM 0.0" SERVICE CLEARANCE BACK * 6.0" LEFT SIDE 30.0" BACK 1.0" RIGHT SIDE 24.0" LEFT SIDE 6.0" FRONT SIDE 30.0" RIGHT SIDE 6.0" 18" WITH FRESHAIR ACCESSORY 30" WITH ECONOMIZER FRONT SIDE 12.0" TOP 36.0" MODEL A B C WCX024G WCX030G 56-1/2 36 29-3/16 WCX036G WCX042G 64 36 29-3/16 WCX048G WCX060G 65-1/8 45 33-3/8 Page 5 REQUIRED CLEARANCE FOR UNiT iNSTALLATiON AND ROOF PENETRATION HOLE SiZE REQUIRED SERVOE SERVOE woo SIDE RAIL / ' "//._ I MODEL NO. A B C D E I E I I E E I E E E _ I I F SERVICE CLEARANCE & PENETRATION DIMENSIONS WCX024-30G 42" 30" "12" 24" 36" 25" WCX036-04G 42" 30" "12" 30" 44" 25" WCX048-06G 42" 30" "12" 36" 50" 25" HOLE IN ROOF __ J_ _ _ Ii _i_ E * 18" WITH FRESH AIR ACCESSORY * 30" WITH ECONOMIZER _ LOCATIONS AND RECOMMENDATIONS These units are designed for outdoor installation. For proper installation, the following recommendations must be considered. NOTE: Unit shipped for horizontal downflow per instruction. installation. Convert to The discharge air from the condenser fans must be unrestricted for a minimum of 3 feet above the unit. Roof Mounting Curb (field assembled BAYCURB030A,038A and BAYCU RB033A, BAYCU RB034A) or a field fabricated curb must be in place before unit is hoisted to the roof. Roof Mounting Curb (frame) must be installed on a flat, level section of the roof(max, of 1/4" per foot pitch), providing a level mounting surface for the unit. In addition, provide sufficient height above the roof to prevent water from entering unit. In locations where deep snows are encountered,RAiSE THE UNIT A MINIMUM OF 12" OFF THE ROOF, DECK OR SLAB--the chance of the coil being blocked with snow wilt be reduced. The water that occurs during the defrost has a better chance of flowing from the vicinity of the unit. Roof Mounting Curb used with WCY--F models is approximately 14" high. This is normally sufficient height to prevent snow blockage and additional clearance is not necessary. Page 6 AVOID LOCATING THE UNIT WHERE SNOW TENDS TO DRIFT. This will reduce the times when it is necessary for the customer to remove the snow from around the unit. MAKE CERTAIN THE CUSTOMER KNOWS THAT SNOW ACCUMULATIONS SHOULD BE REMOVED FROM THE SIDES OF THE UNIT FOR BEST EFFICIENCY. A snow drift barrier may be installed around the unit to prevent a build up of snow on the sides of the unit. The barrier should be of sufficient distance from the unit to prevent restriction of airflow to and from unit. LOCATE THE UNIT SO THAT THE WATER VAPOR THAT DISCHARGES UPWARD DURING DEFROST DOES NOT CONDENSE ON WINDOWS AND FOG THEM OR CAUSE ICICLES TO FORM ON OVERHANGS. 1. Be sure the mounting curb spans structural members (trusses) of the roof, thereby providing sufficient support for weight of the unit, curb and duct(s) plus any accessories (factory or field installed). See Figures 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11 and 12. NOTE. If any internal accessories are to be added to the unit it should be done at the shop if at all practical. 2. Unit should be positioned so Roof-Run-Off water does not pour directly on unit. 3. For"RoofTop Application," unit must be elevated above roof with a mounting Curb or Frame. 4. Exhaust vents or other sources of contaminated air should not be near unit air inlet if outside air is to be introduced as a make-up air or the economizer ventilation feature is to be used. 5. Check the handling facilities to insure the safety of personnel and the unit(s). 6. CAUTION MUST BE TAKEN AT ALL TIMES TO AVOID PERSONAL INJURIES AND/OR DAMAGE TO EQUIPMENT. 7. The unit must be mounted level for proper drainage of defrost water through the holes in the base pan. 8. Flexible duct connectors must be of a flame retardant material. All duct work outside of the structure must be insulated and weatherproofed in accordance with local codes. 9. Roof flashing must be installed to seal the roof curb cavity and must conform to local building codes. 11. Access and service clearances for the unit must be given careful consideration when locating the duct entrance openings. Figures 6 and 8 provide unit dimensions. 12. All fabricated outdoor ducts should be as short as possible. 13. Be sure the hole in the structure for the ducts is large enough to accommodate the fabricated ducts and the insulation surrounding them. (See Figure 6.) CLEARANCES 1. The recommended clearances for single-unit installations are illustrated in Figures 5 and 6. These minimum requirements are not only an important consideration when determining unit placement, but they are also essential to ensure adequate serviceability, maximum capacity, and peak operating efficiency. 2. Any reduction of the unit clearances indicated in this illustration may result in condenser coil starvation, or the recirculation of warm condenser air. Actual clearances which appear to be inadequate should be reviewed with a local sales engineer. IMPORTANT!: To convert to downflow remove covers from the downflow supply and return air openings and place them over the horizontal supply and return air openings (painted side out) and secure with sheet metal screws. 10. Holes through exterior walls must be sealed in accordance with local codes. INSTALLATION UNIT SUPPORT If unit is to be roof mounted, check building codes for weight distribution requirements. Refer to accessory roof curb mounting instructions. Check unit nameplate for supply voltage required. Determine if adequate electrical power is available. Refer to specification sheet. LOCATION AND CLEARANCES Installation of the unit should conform to local building codes or, in the absence of local codes, to the ANSI/N FPA No. 70-1987 National Electrical Code or "Latest Revision." Canadian installations must conform to CSA and local codes. Select a location that will permit unobstructed airflow into the condenser coil and away from the fan discharge and permit unobstructed service access into the compressor compartment. Suggested airflow clearances and service clearances are given in Figure 5. PLACING IMPORTANT!: DO NOT LIFT THE UNIT WITHOUT TESTLIFTING FOR BALANCE AND RIGGING.DO NOT LIFT THE UNIT IN WINDY CONDITIONS OR ABOVE PERSONNEL. DO NOT LIFT THE UNIT BY ATTACHING A CLEVIS, HOOKS, PINS OR BOLTS TO THE UNIT CASING, CASING HARDWARE, ANGLES, TABS OR FLANGES. FAILURE TO OB= SERVE THESE WARNINGS MAY RESULT IN EQUIPMENT DAMAGE. AND RiGGiNG 1. Before preparing the unit for lifting, check the outline drawing for center of gravity for lifting safety. Because of placement of internal components, the unit weight may be unevenly distributed. Approximate unit weights are given in outline drawing on page 3. 4. When the curb and air ducts have been properly installed, the unit is ready to be hoisted to the roof and set in position. I hoisting MPORTANT!: unit. 2. Insert the four lifting tugs in openings provided in drip lip on perimeter of unit. See Figure 7 insert "B". 3. Before hoisting the unit, be sure that the proper method of rigging is used, with straps or slings and spreader bars for protection during lifting. Bars" must be used when 5. IMPORTANT: The unit must be lowered into position P.V.C. rubber tape on the curb flange permits the unit to be repositioned if required without destroying the P.V.C. rubber seals affixed to mounting curb. 6. PLACING UNIT ON MOUNTING CURB--The unit is designed with a perimeter drip lip that is lower than the unit base ban, see Figure 7 insert "A". 7, NOTE. Accessory BA YLIFTOO2M Four (A) lifting lugs are recommended for rigging the unit for hoisting. See Figure 7 insert "B". "Spreader Position the unit drip tip down over and in contact with the outside corner of the curb, as illustrated in Figure 7 insert "A". Continue to lower unit on top of curb, with the unit drip tip astraddle and in contact with both the end and side rail of curb, the unit is now resting on top of curb. 8. Take the two (2) hold down brackets shipped with curb and secure unit to curb with hold down brackets as illustrated in Figure 8 insert "A". Page 7 © SPREADER BARS OUTDOORCOIL END OFUNIT BASE OF UNIT REST ON TOP OF CURB RAILS DRIP LIP ON PERIMETER OF UNIT I P_ BAYLIFT002A DIMPLE LIFTING LUGS CURB CORNER J GASKET NOTE: The inner perimeter of the Drip Lip units should be flush with the outer of the curb on the two sides shown Figure 2 for the location of the unit on the WCX036-060G Models with BAYCU RB030A,038A. SEAL' on all perimeter here. See overhang ® EXISTING SHEET METAL I SCREW HOLD-DOWN WITH CURB FLANGE OF CURB Page 8 iNSTALLATiON ROOFTOP ==UNITS For roof top applications using a field fabricated frame and ducts, use the following procedure: 4. Place the unit on the frame or roof curb. 10. 1. The frame must be located and secured by bolting or welding to the roof. Flashing is required. 5. Secure the unit to the frame or roof curb. 2. The hole in the roof must be prepared in advance of installing the unit. ® TYPICAL ROOFTOP APPLICATIONS RETURN AIR SUP 9 or 6. Insulate any ductwork outside of the structure with at least two (2) inches of insulation and then weatherproof. There must be a weatherproof seal where the duct enters the structure. 7. Complete the installation according following sections of this manual. 3. Secure the ducts to the roof. Refer to Figures to the instructions in the WITH FRAME lwcxo24-O6OG) ,. _ • WEATHER-PROOF DUCT ROOF FLASHING ANGLEIRON FRAME ® TYPICAL ROOFTOP APPLICATION (WCX024=060G WITH FRAME MODELS) / ROOF DUCT SUPPLY ROOF FLASHING AIR FLASHING RETURN AIR FRAME Page 9 iNSTALLATiON GROUND LEVEL ==HORIZONTAL UNITS For ground level installations, the unit should be positioned on a pad the size of the unit or larger• The unit must be level on the pad. The pad must not come in contact with the structure (See Figure 11 .) Be sure the outdoor portion of the supply and return air ducts are as short as possible• 2. Attach the supply and return air ducts to the unit• Proceed with the installation as follows: 4. Complete the installation according following sections of this manual• 1. Place the unit on the pad and the provided• ® 3. Insulate any ductwork outside of the structure with at least 2 inches of insulation and weatherproof• There must be a weatherproof seal where the duct enters the structure• to the instructions in the five (5) rubber isolators TYPICAL GROUND LEVEL APPLICATION (WCX024-060G MODELS) OUTDOOR AIR DISCHARGE I 'l RETURN AIR SUPPLY AIR DUCT I ' DUCT SIDING I_P" OUTDOOR INTAKE AIR SUPPORT PAD FOUNDATION EXTERIOR WALL INSULATE WEATHERPROOF OR RAIN SHIELD FLEXIBLE DUCT CONNECTORS ISOLATORS (1 PER CORNER AND 1 UNDER UNIT CONTROL BOX) 2046eps DUCTWORK ATTACHING DOWNFLOW DUCTWORKTO ROOF CURB Supply and return air flanges are provided on the roof curb for easy duct installation• All ductwork must be run and attached to the curb before the unit is set into place• ATTACHING HORIZONTAL DUCTWORK TO UNiT All conditioned ing and cooling insulation with weatherproofed air ductwork should be insulated to minimize heatduct losses• Use a minimum of two (2) inches of a vapor barrier• The outside ductwork must be between the unit and the building• Follow these guidelines for ductwork construction: Connections to the unit should be made with three-inch canvas connectors to minimize noise and vibration transmission• Elbows with turning vanes or splitters are recommended to minimize air noise and resistance• The first elbow in the ductwork leaving the unit should be no closer than two feet from the unit, to minimize noise and resistance• Page 10 When attaching ductwork to a horizontal unit, provide a flexible watertight connection to prevent noise transmission from the unit to the ducts• The flexible connection must be indoors and made out of heavy canvas• NOTE: Do not draw the canvas taut between the solid ducts. } ® DUCT ATTACHMENT METHODS AIR PROOF \ THIS SEAM / AIR PROOF _THIS SEAM BASE FIELD DUCT,ql X U FLANGE _ FIELD DUCT FIELDDUCT 4L 'UNIT DUCT FLANGE _TBASE Lt UNIT DUCT I FLANGE UNIT BASE / AIR PROOF UNIT DUCT FLANGE UNITFLANGEDUCT_ UNIT " FIELD BASE NOT RECOMMENDED DUCT WITH BUTYL SILICONE OR FIELD DUCT DOWNFLOW The following UNIT DUCT FLANGE / I_,. u _ warning complies with State of California AWARNING: THIS SEAM FIELD DUCT law, Proposition 65. This product contains fiberglass wool insulation! Fiberglass dust and ceramic fibers are believed by the State of California to cause cancer through inhalation. Glasswool fibers may also cause respiratory, skin, or eye irritation. HORIZONTAL CONDENSATE A 3/4-inch female NPT condensate drain connection is provided on the evaporator access panel end of the unit. See Figure 4. Provide a trap and fill it with water before starting the unit to avoid air from being drawn through. Follow local codes and standard piping practices when running the drain line. Pitch the line downward away from the unit, Avoid long horizontal runs, See Figure 13. DRAIN PiPiNG TYPICAL CONDENSATE DRAIN PiPiNG 3/4" PVC OR COPPER TUBING AND F NOTE: Do not use reducing fittings in the drain lines. The condensate drain must be: • Made of 3/4" pipe size. • Pitched 1/4" per foot to provide free drainage to convenient drain system, 1-1/2" MIN. • Trapped. • Must not be connected to closed drain system. Page 11 FILTER INSTALLATION TABLE 1 Filters are to be used with the WCX024-060G heating/cooling units. The basic unit does not have filters in it. However, a filter frame accessory is offered that will allow filters to be installed within the unit. WCX024G NOMINAL CFM 800 WCX030G 1000 3.33 0.05 WCX036G 1200 4.00 0.05 WCX042G 1400 4.67 0.05 Otherwise a filter rack must be installed by the installer in the duct work. WCX048G 1600 5.33 0.05 WCX060G 2000 6.67 0.05 AiR FILTERS UNIT Affix the filter label supplied with the unit adjacent to the filter area. ELECTRICAL CONNECTIONS and grounding must be installed in accordance with in the absence of local codes, with the National ANSI/NFPA 70, Latest Revision. POWER It is important that proper electrical power be available for the unit. Voltage variation should remain within the limits stamped on the unit nameplate. DISCONNECT Provide an approved weather-proof disconnect either on the side of the unit or within close proximity and within sight of the unit. OVER CURRENT PROTECTION The branch circuit feeding the unit must be protected as shown on the unit rating plate. POWER CONTROL WIRING (CLASS II) Low voltage control wiring should not be run in conduit with power wiring unless Class 1 wire of proper voltage rating is used. Route the thermostat cable or equivalent single leads of No. 18 AWG colored wire from the thermostat subbase terminals through the rubber gromment on the unit. See Figure 5 for the control entry location. Make connections as shown on the unit wiring diagram and in Figure 14. TABLE Provide flexible conduit supports whenever vibration transmission may cause a noise problem within the building structure. Be sure all connections wires since this will damage the control Recommended wire sizes and lengths for installing the unit thermostat are provided in Table 2. The total resistance d these low voltage wires must not exceed one (1) ohm. Any resistance in excess of 1 ohm may cause the control to malfunction because of the excessive voltage drop WIRING The power supply lines must be run in weathertight conduit to the disconnect and into the bottom of the unit control box. Provide strain relief for all conduit with suitable connectors. 2 THERMOSTAT WIRE SIZE AND MAXIMUM LENGTH WIRE SIZE 18 16 14 MAXIMUM LENTGH (Ft) 75 125 200 are made tight. See Figure 14. NOTES: For branch circuit wiring (main power supply to unit disconnect), wire size for the length of run should be determined using the circuit ampacity found on the unit nameplate and the N.E.C. For more than 3 conductors in a raceway or cable, see the N.E.C. for derating the ampacity of each conductor. GROUNDING: THE UNiT MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR THE NATIONAL ELECTRIC CODE. NOTE: Ground the unit diagram for location. Page 12 WIRING Do not short thermostat transformer. SWITCH FILTER RESISTANCE 0.05 *Filters must be installed in the return air system. The above square footages are based on 300 F.P.M. face velocity. If permanent filters are used, size per mfg. recommendation with clear resistance of 0.05"WC. ELECTRICAL ELECTRICAL Electrical wiring local codes or, Electrical Code FILTER* (Sq Ft) SIZE 2.67 internally as provided. See wiring THERMOSTAT HEAT ANTICIPATOR The thermostat heat anticipators should be set to equal the amperage draw of the Wl thermostat circuit. IMPORTANT: Upon completion of wiring check all electrical connections, including factorywiringwithinthe unit. Make sure all connections are tight. Replace and secure all electrical box covers and access doors before leaving the unit or turning on the power to the unit. Afterallelectrical wiringiscomplete, setthethermostat system Thermostat System Switch until power has been applied long enough to evaporate any liquid R-22 in the compressor. It is recommended that the sump heater be energized for eight (8) hours prior to starting. switch in the OFF position so that the compressor will not run and then apply power by closing the system main disconnect switch. This will activate the compressor sump heat. Do not change the ® WCX=G FIELD WIRING P/,,CKA( ) ii#' ] PUvIP T CO TRCI N DIAGRAM I UQX I I i I " I 1 o Io e F I i .......................................................................... _L , 56B(BL) [ ':OM_,< '\ /,N I (}O'qF>FR i SSOR 1S] I' C(BR) S /,©E [li(IR (1 II A 'A2 DEFROST ¢ONTRO_ j I UN T i{ v pl _OwE n O_ '/OI T/,GE 0:, R 24 T S_GN_i VOt TS #RE,", .......... NOTES: ai,}E _i 5p c,4:R ;/,[ 1 FUSED DISCONNECT SIZE, POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH CODES [ Rb05? a; I , _,,,, R UN}T I EATER CTE F IC 35A( -_ i Y' < /[ 1,6 2 BE SURE POWER SUPPLY EQUIPMENT AND HEATER I 3 LOW VOLTAGE CONDUCTOR. SINCLE PO,VEF_ AC C E S S C)R Y BOX -uNI_ CO_RCL ENiRY F I O C C)N N E:C [ I 0 N S UNiT HEATER AREA _ [) _ NS]A ,,,<1 NO 2 ECONOMI ZER CONNEC (NOT APP ACCES ! ONS C,SY 4 CAB E TO TItE wc_/ F rODE S I) _2_ I 111 ............ 177 II II II................................................ J I _' 'R ] £_'• OA 01,:, ,_ !,£ ,2_,, ....... I I TYP C# I,dxq{I,I I 10 2 S _GE NTRY C,t DC}OR A,CCESSQRY .... ,r,q _ , 3ONN ,3T 'ONS WIRE IS 9 WHEN THE BAYECON054A OR -055A ECONOMIZER IS INSTALLED THE BAYRLAY003 RELAY ACCESSORY KIT IS REQUIRED TO INTERFACE THE ECONOMIZER TO THE HEAT PUMP FOR PROPER SYSTEM OPERATION, WHEN THE BAYECON054B OR -055B OR 073A ECONOMIZER IS INSTALLED, THE BAYRLAY004A RELAY ACCESSORY KIT IS REQUIRED TO INTERFACE THE ECONOMIZER TO THE HEAT PUMP FOR PROPER SYSTEM OPERATION ...... 4:!-........... y , { RATING ACCESSORY IS NOT ELECTRIC HEATER, WIRES AND THE 'W' AND 'X2' HAS TWO HEATING STAGES THE 41C(BR) SECOND STAGE ELECTRIC HEAT, L (" FOR CURRENT 8 THE 41A(BR) WIRE IS FIRST STAGE ELECTRIC HEAT IF THE ELECTRIC HEATER ACCESSORY 44: ..... vOL A©E AkEA 5 Pii PO'¢4R MINIMUM 7 FIG 3 DEMONSTRATES CONNECTION OF THE OUTDOOR THERMOSTAT ACCESSORY ONLY, FOR FURTHER UNIT CONNECTION DETAILS REFER TO THE OTHER FIGURES I [ ,?RE GIOUND SEE HEATER NAMEPLATE OF HEATER USED. 6 IF ELECTRIC HEATER INSTALLED OMIT THE ASSOCIATED POWER THERMOSTAT WIRES liil ....... AGREES WITH NAMEPLATE TO BE 18 AWG 5 SEE UNIT AND HEATER DIAGRAM FOR ELECTRICAL CONNECTION DETAILS, liil I I WIRING THE BAYSTAT033A OUTDOOR THERMOSTAT ACCESSORY KIT CONTAINS A THERMOSTAT AND A RELAY THE RELAY IS NOT REQUIRED TO BE USED IN THIS APPLICATION, iN ER COM OqE N i f ; Ix( ....... 24¸','¸ I iNE _ FACTORY v',' R i NG __ 24v' _ L NE " ;/ [ iEI D ?_ R NO W I I_r COl ()R ' J)E S SNA 1 i ON o JTDOOR ACCE SSO_Y BAY IA I O53A NOIE 10 BK _ BI BR OR ,'_CK j PR I:LJRI:_ _1 LJL J RD RF[ E BROWN ©RF N i WH Y WHI IF YI I [ OW (DR o _ANCFi P c_ liER',O Ai Page 13 START - UP PRE-START QUICK CHECKLIST • Is the unit properly located and level with the proper clearance? See Figure 5. • Is the duct work correctly sized, run, taped, insulated, and weatherproofed with proper unit arrangement. See Ductwork Installation section. To start the unit in the cooling mode, set the thermostat system switch to COOL and move the thermostat COOL indicator to a setting below room temperature. The condenser (outdoor) fan motor compressor and evaporator (indoor) fan motor will operate automatically. OPERATING • Is the condensate line properly sized, run, trapped, and pitched? • Isthe filter of the correct size and number? Is it clean and in place? • Is the wiring properly sized and run according to the unit wiring diagram? • Are all the wiring connections, including those in the unit, tight? • Has the unit been properly grounded and fused with the recommended fuse size? See Wiring Data. PRESSURES After the unit has operated in the cooling mode for a short period of time, install pressure gauges on the gauge ports of the discharge and suction line valves. Check the suction and discharge pressures and compare them to the normal operating pressures provided in the unit's SERVICE FACTS. NOTE: Do not use the pressures from the unff's SERVICE FACTS to determh_e the unit refrigerant charge. The correct charge is shown on the unit nameplate. To charge the system accurately, weigh in tlhe charge according to the unit nameplate. VO LTAG E • Isthe thermostat level, correctly wired, welt located, and set for the proper heat anticipation? • Have the air conditioning systems been checked at the service ports for charge and leak tested if necessary? • Do the condenser fan and indoor blower turn free without rubbing, and are they tight on the shafts? • Has the indoor blower speed been determined and the proper speed been set? See the Unit Wiring Diagram. • Has all work been done in accordance with applicable local and national codes? • Are all covers and access panels in place to prevent air loss and safety hazards? STARTING THE UNIT IN THE COOLING MODE CAUTION: Before starting the system on the cooling cycle, turn the thermostat switch to OFF and close the unit disconnect switch. This procedure energizes the compressor crankcase heater, vaporizing any liquid refrigerant in the crankcase. This is a precaution against foaming at startup which could damage the compressor bearings. Allow the heater to operate a minimum of eight (8) hours. NOTE: See the section on "Sequence of Operation" for a description of the cooling operating sequence. WARNING: DO NOT OPERATE THE UNIT WITHOUT THE EVAPORATOR FAN ACCESS PANEL IN PLACE. REINSTALL THE ACCESS PANEL AFTER PERFORMING ANY MAINTENANCE PROCEDURES ON THE FAN. OPERATING THE UNIT WITHOUT THE ACCESS PANEL PROPERLY INSTALLED MAY RESULT IN SEVERE PERSONAL INJURY OR DEATH. Page 14 With the compressor operating, check the line voltage at the unit. The voltage should be within the range shown on the unit nameplate. If low voltage is encountered, check the size and length of the supply line from the main disconnect to the unit. The line may be undersized for the length of the run. COOLING SHUT DOWN Place the system selector in the OFF position or reset thermostat at a setting above room temperature. Do not de-energize the main power disconnect except when unit it to be serviced. Power is required to keep the heat pump compressor warm and boil off refrigerant in the compressor. STARTING THE UNIT IN THE HEATING MODE NOTE: See the section on "Sequence of Operation" for a description of the heat pump heating operating sequence. Check to make sure all grilles an registers are open an all unit access doors are closed before start-up. Slowly set the thermostat above rom temperature until achieving a first stage call for heat and place the fan switch in the AUTO or ON position. HEATING SHUT-DOWN Place the system selector switch at OFF or place the heating selector lever at a setting below room temperature. SEQUENCE OF OPERATION GENERAL Operation of the unit heating and cooling cycles is automatic for HEAT and COOL functions. (The optional automatic changeover thermostat, when in the AUTO position, automatically changes to heat or cool with sufficient room temperature change.) The fan switch can be placed in either the ON position, causing continuous evaporator (indoor) fan operation, or the AUTO position causing fan operation to coincide with heating or cooling run cycles. COOLING MODE (NOTE: TSH & TSC are contacts internal to the indoor thermostat.) With the disconnect switch in the ON position, current is supplied to the compressor crankcase heater and control transformer. (The outdoor fan relay (ODF) relay is energized through normally closed contacts on the defrost timer control (DFC) on the 460V and 600V units only.) The cooling cycle is enabled through the low voltage side of the control transformer to the "R" terminal on the indoor thermostat. With the system switch in the AUTO position and TSC1 contacts closed, power is supplied to the "O" terminal on the indoor thermostat to the switchover valve coil (SOV). This energizes the switch-over valve (SOV) and places it in the cooling position (it is in the heating position when de-energized). When the indoor temperature rises 1-1/2 degrees, TSC-2 contacts close, supplying power to the "Y" terminal on the indoor thermostat, and to the compressor contactor (CC). This starts the outdoor fan motor and compressor. The TSC-2 contacts also provide power to the "G" terminal which provides power to the fan relay (F) starting the indoor fan motor. HEATING MODE With the disconnect switch in the "ON" position, current is supplied to the compressor crankcase heater and control transformer. (The outdoor fan relay (ODF) is energized through normally closed contacts on the defrost timer control (DFC) on the 460V and 600V units.) Starting at the "R" terminal on the indoor thermostat, current goes through the system switch (which is in "AUTO" position) to the TSH=I contacts. When closed, these contacts supply power to terminal "Y" on the indoor thermostat as well as to the heating anticipator. The switch-over valve will not energize because of the high resistance of the heating anticipator in the thermostat. Power is provided from "Y" to the compressor contactor (CC) which starts the compressor and outdoor fan motor. The indoor thermostat contact TSH=I also provides power to "G" terminal on the indoor thermostat energizing the fan relay (F), which starts the indoor fan motor. thermostat. When placed in the emergency heat position, it will disable the compressor, bypass the outdoor thermostats, if provided, and engage the supplementary electric heaters and indoor fan. DEMAND DEFROST OPERATION During the heating cycle, the outdoor coil may require a defrost cycle which is determined by the demand defrost control (DFC). This control continuously measures the outdoor coil temperature (CBS) and the outdoor ambient temperature (ODS-B) and calculates the difference or detta-T measurement. When the calculated detta-T is met, the demand defrost control (DFC) opens the circuit to the outdoor fan motor (ODM) and energizes the switch-over valve (SOV), placing the unit in the cooling mode to defrost the outdoor coil. The outdoor coil temperature sensor (CBS) terminates the defrost cycle, or times off after twelve minutes in defrost, the (DFC) energizes the outdoor fan motor (ODM) and twelve seconds later de-energizes the (SOV), which returns the unit to the heating mode. Supplementary electric heat, if provided, is brought on to control indoor temperature during the defrost cycle. ICM FAN MOTOR ADJUSTMENTS (WCX060G ONLY) If the airflow needs to be increased or decreased, see the Airflow Table in the Service Facts. Information on changing the speed of the blower motor for the WCY060F is in the Blower Performance Table. Blower speed changes are made on the ICM Fan Control mounted in the control box. The ICM Fan Control controls the variable speed motor. There is a bank of 8 dip switches, (See Figure 15), located at the lower right side of the board. The dip switches work in pairs to match the cooling/heat pump airflow (CFM/TON), Fan off-delay options, and electric heat airflow adjustment. The switches appear as shown in Figure 15. ® ICM FAN CONTROL CFM SELECTION . < LIG_ DIP _/ .SWITCHES CNT03600 _qz 21C800796P01_ CFM FAN Y Y LO < SUPPLEMENTARY NEAT The supplementary electric heat is brought on when the indoor temperature drops 1-1/2 degrees below the thermostat setting. TSN=2 contacts close providing power to the "W" terminal on the indoor thermostat and to the supplementary heater control circuit. NOTE. The fan relay (F) must have been energized. An outdoor thermostat may have been added to disallow the second stage (if provided) of electric heat above a selected outdoor temperature. If the outdoor temperature falls below the setting on the outdoor thermostat, this additional heater stage will come on. When the outdoor air temperature rises, and the outdoor T-stat setpoint is reached, the system will revert back to first stage electric heating. When the indoor ambient is satisfied, TSH=2 contacts will open and the unit will revert back to the compressor only heating mode and then off. For emergency heat (use of supplementary electric heat only), an emergency (EMERG) heat switch is provided within the R W3 W2 Wl 12345678 DIP SWITCHES (TYPICAL SETTINGS) Page 15 DEMAND DEFROST SYSTEM DEFROST CONTROL PiN IDENTIFICATION The demand defrost control measures heat pump outdoor ambient temperature with a sensor located outside the outdoor coil. A second sensor located on the outdoor coil is used to measure the coil temperature. The difference between the ambient and the colder coil temperature is the difference or detta-T measurement. This detta-T measurement is representative of the operating state and relative capacity of the heat pump system. By measuring the change in delta-T, we can determine the need for defrost. The coil sensor also serves to sense outdoor coil temperature for termination of the defrost cycle. FAULT DETECTION A fault condition is indicated by the flashing control inside the heat pump control box. light on the defrost PIN IDENTIFICATION (See Figure) 1. TEST_COMMON (Shorting any of the other pins to this pin causes the function of the other pin to be executed. Leaving this pin open results in the normal mode of operation.) to this pin speeds up 3. FRC_DFT = Forced Defrost (Short TEST_COMMON to this pin for two (2) seconds to initiate a forced defrost. Remove the short after defrost initiates.) PROCEDURE FORTESTING DFT [] D S TEST COMMON D TST In normal operation, the defrost control light wilt flash once each second. If the light is flashing more than once per second or not-atall, refer to the service manual for that unit. 2. TST = Test (Shorting TEST_COMMON all defrost board timings.) FRC DEFROST CONTROL b. 24V AC between R & B c. 24V AC between Y & B with unit operating d. Defrost initiation when TEST_COMMON pin. WARNING: Unplug the sensor and measure the resistance with a good quality ohmmeter (Simpson 260 or equiv.). Read the value as quickly as possible to prevent the meter current from changing the resistance reading. Using the chart on the right, locate (as close as possible) the actual sensor temperature. The measured resistance should be relatively close to the resistance value shown in the chart. Example: = 19°F. = 46K ohms pin is shorted This sensor is good since the measured value is relatively close to the chart value. TEMP °F 86 81 75 70 65 59 55 50 45 41 36 32 25 19 14 10 5 0 RESISTANCE 7.85K 8.85K 10.24K 11.59K 13.14K 15.32K 16.93K 19.41K 22.20K 24.76K 28.45K 31.84K 37.50K 46.44K 53.94K 57.64K 67.06K 78.05K FLASH RATE INDICATIONS: I -- Flash/Second = Normal operation. 2-- Flashes/Second = Fault A (Low AT) i.e.: Inoperative compressor, toss of charge, open ambient sensor, shorted coil sensor. 3-- Flashes/Second = Fault B (20 defrosts terminated on time) Fault C (High AT) i.e.: SOV stuck in heating, shorted ambient sensor, open coil sensor, closed TXV, OD motor failure, OD fan on in defrost, undercharged 4--Flashes/Second to DONOT connect 24VAC tT oI (ODS-A) terminal. ODS-A thermistor WILL BE BLOWN. Measure the temperature the subject sensor is exposed to. If the sensor is mounted on a tube, place the lead on an Annie A-8 (or equiv.) temperature tester on the same tube near the sensor and insulate the bulb. Measured Resistance FRC_DFT If a defrost control problem is suspected, proceed to DEMAND DEFROST CONTROL CHECKOUT in this Service Facts. SENSORS Sensor temp. CHECKOUT Normal operation requires: a. LED on board flashing 1 time/second. unit. = FaultA&CorA&B For additional information consult Pub. No. 34-1001 Heat Pump Defrost Controls. Page 16 DEMAND DEFROST CONTROL CHECKOUT SYMPTOMS CHECKS YES/NO 1. LED off. 1.24V R-B & Y-B at board, with unit running? 2.Short FRC_DFT pin to TEST_COMMON Is defrost cycle initiated? 2. LED flashing very rapidly (greater than 4 times/sec) or appears to be on continuously. 3. Control does not initiate a normal defrost. TEST_COMMON pin. Repair low voltage wiring. Y Complete N Replace defrost control. Y LED is bad but control will still function. Y Remove short. N Replace defrost control. N Check refrigerant circuits for balanced distribution of refrigerant if OD coil is frosting and delta T is not increasing N Refer to SYMPTOM #1. Y Complete N Repair low voltage wiring. Y Complete OD Temp. below 49°E OD Coil temp. below 35°F.? "Delta" T increasing? 2. Check for 24V Y-B at board with unit running. 3. Check sensors for correct mounting (connection) and resistance. Check #2. Check #3. Remount or replace sensor if necessary. 4. Short FRC_DFT pin to TEST_COMMON Is defrost cycle initiated? pin. N Replace defrost control. Y Y-B signal or control may be intermittent N Repair low voltage wiring. Y Replace defrost control. 24V R-B & Y-B at board with unit running? 5. Defrost initiates manually but terminates 6. Defrost initiates manually but terminates on time. Check #2. pin shorted to TST pin? 1. LED flashing? 4. Control does not initiate a forced defrost. ACTIONS N in less than 10 seconds. Replace defrost control. 1. Coil sensor circuit open or reading at a very high resistance? Y Replace coil sensor. 2. Does OD fan cycle off in defrost? N Replace defrost control. Be sure OD coil is clean. N Complete 1. Coil sensor open or reading a very high resistance? Y Replace coil sensor. N Complete Y Replace ambient sensor. 3. OD fan off in defrost? N Replace defrost control. 1.TEST_COMMON Y 3. Windy weather preventing normal termination? 7. Defrost initiates on approximately 15/25 minute intervals. 2. Ambient sensor reading less than normal? 8. Defrost initiates on approximately 30/45 minute intervals. pin shorted to TST pin? Y Complete less than N Replace defrost control. 5. OD fan motor off in defrost. See SYMPTOM #9. 6. Verify proper SOV operation. Replace if necessary. Has J1 been cut? Replace defrost control. The soft-switch time is defeated when J1 is cut. Y 11. ODS-A burned out. 1. B to T greater than 10 volts? 13. On SCROLL bearing units, no 30 second off delay at defrost initiation. SYMPTOM #3. Adjust as needed. 9. OD fan runs during defrost. 12. On SCROLL bearing units, compressor does not operate. Remove short. Replace defective sensor (Clear coil and reset Emergency heat light). 3. Verify correct system charge. 10. No SOV delay on defrost termination. Check #3. N 2. Do both sensors check OK? 4. Verify a "forced defrost" terminates 15 minutes. Check #2. 1.24V R-B at board & 24V Y-B at board? 2. Check protective devices in YO circuit. 24V YO-B present after 30 seconds. Check voltage between control terminals 2 and 7,force a defrost cycle. Is 24V present for 30 seconds and 0V thereafter? N Replace defrost control. Y Check low voltage wiring for miswire. N Check for short in low voltage wiring. N Repair low voltage wiring. N Y-B signal or control may be intermittent N Replace defrost control. Page MAINTENANCE ROUTINE MAINTENANCE BY OWNER You can do some of the periodic maintenance functions for your WCX-G unit yourself; this includes replacing the disposable or cleaning the permanent air filters, cleaning the unit cabinet, clearing the condenser coil, and conducting a general unit inspection on a regular basis. Be sure to inspect them at least once each month when the system is in constant operation. (In new homes, check the filters every week for the first four (4) weeks.) If you have disposable-type filters, replace them with new filters of the same type and size. Do not attempt to clean disposable filters. Permanent-type filters can be cleaned by washing them with a mild detergent and water. Make sure that the filters are thoroughly dry before re-installing them in the unit (or duct system). NOTE: It may be necessary to replace permanent filters annually if washing fails to clean the filter or if the filter shows signs of deterioration. Be sure to use the same type and size as was originally installed. CONDENSER COIL Unfiltered air circulates through the unit's condenser coil and can cause the coil's surface to become clogged with dust, dirt, etc. To clean the coil, vertically (i.e., with the fins) stroke the coil surface with a soft-bristled brush. Be sure to keep all vegetation away from the condenser coil area. MAINTENANCE PERFORMED BY SERVICEMAN-HEATING SEASON Complete the unit inspections and service routines described below at the beginning of each heating season. • Visually inspect the unit to ensure that the airflow required for condenser coil is not obstructed from the unit. • Inspect the control panel wiring to verify that all electrical connections are tight and that the wire insulation is intact. WARNING: TO PREVENT INJURY OR DEATH DUE TO ELECTRICAL SHOCK OR CONTACT WITH MOVING PARTS. LOCK UNIT DISCONNECT SWITCH IN OPEN POSITION BEFORE SERVICING UNIT. WARNING: TO AND PREVENT AN EXPLOS,ON OR POSSIBLE INJURY, DEATH EQUIPMENT DAMAGE, I DO NOT STORE COMBUSTIBLE MATERIALS, GASOLINEI OR OTHER FLAMMABLE VAPORS OR LIQUIDS NEAR THE I UNIT. l I The following warning complies WARNING: with State of California law, Proposition This product 65. contains fiberglass wool insulation! Fiberglass dust and ceramic fibers are believed by the State of California to cause cancer through inhalation. Glasswool fibers may also cause respiratory, skin, or eye irritation. PRECAUTIONARY MEASURES • Avoid breathing fiberglass dust. MAINTENANCE PERFORMED BY SERVICEMAN-COOLING SEASON To keep your unit operating safely and efficiently, the manufacturer recommends that a qualified serviceman check the entire system at least once each year and any other time that you feel one is needed. Your serviceman should examine these areas of your WCY-F unit: • filters (for cleaning or replacement) • motors and drive system components • gaskets (for possible replacement) • safety controls (for mechanical cleaning) • electrical components and wiring (for possible replacement and connection tightness) • Use a NIOSH approved dust/mist respirator. • Avoid contact with the skin or eyes. Wear longsleeved, loose-fitting clothing, gloves, and eye protection. • Wash clothes separately from other clothing: rinse washer thoroughly. Operations such as sawing, blowing, tear-out, and spraying may generate fiber concentrations requiring additional respiratory protection. Use the appropriate NIOSH approved respirator in these situations. FIRST AID MEASURES Eye Contact • condensate drain (for cleaning) • unit duct connections (to see that they are physically sound and sealed to the unit casing) • unit mounting support (for structural integrity) • the unit (for obvious unit deterioration) Page 18 Skin Contact Flush eyes with water to remove dust. If symptoms persist, seek medical attention. Wash affected areas gently with soap and warm water after handling. LiMiTED WARRANTY HiGH EFFiCiENCY HEAT PUMP WCZ, WCY AND WCX Models Less Than 20 Tons for Residential Use* (Parts Only) This limited warranty is extended by American Standard Inc., to the original purchaser and to any succeeding owner of the real property to which the Heat Pump is originally affixed, and applies to 3roducts purchased and retained for use within the U.S.A. and Canada. If any part of your Heat Pump fails because of a manufacturing defect within five years from the date of the original purchase, Warrantor will furnish without charge the required replacement part. Any local transportation, related service labor, diagnosis calls, refrigerant and related items are not included. In addition, if the sealed motor-compressor(s) fail(s) or the outdoor or both events occurring because of a manufacturing defect within date of original purchase, Warrantor will furnish without charge the and/or outdoor coil. Any local transportation, related service labor, related items are not included. coil* should become defective, either the sixth through tenth year from the required replacement compressor diagnosis calls, refrigerant and *NOTE: If your Heat Pump is installed within one mile of salt water, including but not limited to seacoasts and inland waterways, your outdoor coil warranty as stated above is limited to five years from the date of original purchase. This limited warranty does not cover failure of your Heat Pump if it is damaged while in your 3ossession, damage caused by unreasonable use of the Heat Pump and/or damage from failure properly maintain the Heat Pump as set forth in the Use and Care manual (see Proper Maintenance section). to This limited warranty applies to product installed on or after 10/1/2001 where product is manufactured after 1/1/2000.This limited warranty is not retroactive to any installations prior to 10/1/2001 or on product 3roduced prior to 2000. THE LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES, WHETHER IN CONTRACT OR IN NEGLIGENCE, EXPRESS IMPLIED, IN LAW OR IN FACT, INCLUDING BUT NOT SPECIFICALLY LIMITEDTO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR USE, AND IN NO EVENT SHALL WARRANTOR BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states exclusion or not apply to rights which OR do not allow limitations on how long an implied limited warranty lasts or do not allow the limitation of incidental or consequential damages, so the above limitation or exclusion may you.This limited warranty gives you specific legal rights, and you may also have other vary from state to state. Parts will be provided by our factory organization through an authorized service organization in your area listed in the yellow pages. If you wish further help or information concerning this limited warranty, contact: American Standard Inc. GW-624-1802 Troup Highway Tyler, TX 75711-9010 Attention: Manager, After Sales Support Page 19 equipment is used for a commercial application. A commercial use is any application purchaser uses the product for other than personal, family or household purposes. where the end LiMiTED WARRANTY HiGH EFFiCiENCY HEAT PUMP WCZ, WCY, WCX, WCC, WCD, WCH, WCM AND WSC Models Less Than 20 Tons for Commercial Use* (Parts Only) This warranty is extended by American Standard Inc., to the original purchaser and to any succeeding owner of the real property to which the Heat Pump is originally affixed, and applies products purchased and retained for use within the U.S.A. and Canada. There is no warranty against corrosion, erosion or deterioration. to If any part of your Heat Pump fails because of a manufacturing defect within one year from the date of the original purchase, Warrantor will furnish without charge the required replacement part. In addition, if the sealed motor-compressor fails because of a manufacturing defect within the second through fifth year from the date of original purchase, Warrantor will furnish without charge the required replacement compressor. Warrantor's obligations and liabilities under this warranty are limited to furnishing EO.B. Warrantor factory or warehouse replacement parts for Warrantor's products covered under this warranty. Warrantor shall not be obligated to pay for the cost of lost refrigerant. No liability shall attach to Warrantor until products have been paid for and then liability shall be limited solely to the purchase price of the equipment under warranty shown to be defective. THE WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES, WHETHER IN CONTRACT OR IN NEGLIGENCE, EXPRESS OR IMPLIED, IN LAW OR IN FACT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR USE, AND IN NO EVENT SHALL WARRANTOR BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. American Standard Inc. GW-604-4800 Troup Highway Tyler, TX 75711-9010 Attention: Manager, After Sales Support * This warranty is for commercial usage of said equipment and not applicable when the equipment is used for a residential application. Commercial use is any application where the end purchaser uses the product for other than personal, family or household purposes. Since The Trane Company has a policy of continuous product and product data improvement, it reserves the right to change design and specification without notice, The Trane Company Unitary Products Group 6200 Troup Highway Tyler, TX 75707-9010 An American-Standard Page 20 Company o( )os Technical Literature - Printed in U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 20 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Thu Jun 04 04:13:44 2009 Author : Title : Subject :EXIF Metadata provided by EXIF.tools