Tagsys MEDIOP101WIFI RFID Tag Reader User Manual Manual

Tagsys S.A. RFID Tag Reader Manual

Contents

Manual

Download: Tagsys MEDIOP101WIFI RFID Tag Reader User Manual Manual
Mirror Download [FCC.gov]Tagsys MEDIOP101WIFI RFID Tag Reader User Manual Manual
Document ID645955
Application IDSZ9KQP7Fi/6f+qFOoJTRwQ==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize127.88kB (1598487 bits)
Date Submitted2006-04-11 00:00:00
Date Available2006-04-11 00:00:00
Creation Date2006-03-03 17:04:49
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2006-03-03 17:04:49
Document TitleMicrosoft Word - Medio P101-WIFI User Guide_1.0.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: plecire

Medio P101-WIFI
User's Guide
Revision 1.0
February 2006
Medio P101-WIFI
Publishing Information
Disclaimer and Limitation of Liability
All information herein is either public information or is the property of and owned solely by TAGSYS who shall have and
keep the sole right to file patent applications or any other kind of intellectual property protection in connection with such
information.
Nothing herein shall be construed as implying or granting to you any rights, by license, grant or otherwise, under any
intellectual and/or industrial property rights of or concerning any of TAGSYS’ information.
This document can be used for informational, non-commercial, internal and personal use only provided that:
ƒ
the copyright notice below, the confidentiality and proprietary legend and this full warning notice appear in all copies.
ƒ
this document shall not be posted on any network computer or broadcast in any media and no modification of any
part of this document shall be made.
Use for any other purpose is expressly prohibited and may result in severe civil and criminal liabilities.
The information contained in this document is provided “AS IS” without any warranty of any kind. Unless otherwise
expressly agreed in writing, TAGSYS makes no warranty as to the value or accuracy of information contained herein.
The document could include technical inaccuracies or typographical errors. Changes are periodically added to the
information herein. Furthermore, TAGSYS reserves the right to make any change or improvement in the specifications
data, information, and the like described herein, at any time.
Therefore TAGSYS assumes no liability and is not responsible for customer applications or product or software which
include TAGSYS products.
TAGSYS HEREBY DISCLAIMS ALL WARRANTIES AND CONDITIONS WITH REGARD TO THE INFORMATION
CONTAINED HEREIN, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT. IN NO EVENT SHALL TAGSYS BE LIABLE, WHETHER
IN CONTRACT, TORT OR OTHERWISE, FOR ANY INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES OR ANY
DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO DAMAGES RESULTING FROM LOSS OF USE,
DATA, PROFITS, REVENUES, OR CUSTOMERS, ARISING OUT OF OR IN CONNECTION WITH THE USE OR
PERFORMANCE OF INFORMATION CONTAINED IN THIS DOCUMENT.
TAGSYS does not and shall not warrant that this product/system/equipment will be resistant to all possible attacks, and
shall not incur, and disclaims, any liability in this respect. Even if each product is compliant with current security
standards in force on the date of their design, security mechanisms' resistance necessarily evolves according to the
state-of-the-art in security and notably under the emergence of new attacks. Under no circumstances shall TAGSYS be
held liable for any third party actions, and in particular in case of any successful attack against systems or equipment
incorporating TAGSYS products.
TAGSYS disclaims any liability with respect to security for direct, indirect, incidental or consequential damages that result
from any use of its products. It is further stressed that independent testing and verification by the person using the
product is particularly encouraged, especially in any application in which defective, incorrect, or insecure functioning
could result in damage to persons or property, denial of service, or loss of privacy.
© 2000-2006 TAGSYS. All rights reserved.
Microsoft, Visual C++, Windows, and Windows NT are either registered trademarks or trademarks of Microsoft
Corporation in the U.S.A. and/or other countries.
I-Code is a registered trademark of Philips.
Tag-It is a registered trademark of Texas Instruments.
Printed in France.
TAGSYS – 180 Chemin de St Lambert, 13821 LA PENNE SUR HUVEAUNE, France.
Tel: +33 (0)4.91.27.57.00 / Fax: +33 (0)4.91.27.57.01
Document Reference: DOC12070A0
2/42
Revision 1.0
February 2006
Read This First
Read This First
Welcome to the TAGSYS range of products operating at the 13.56 MHz frequency. This range of
products is used to implement high-quality RFID systems for demanding applications.
This document provides information about how to install and use the Medio P101-WIFI reader.
Audience
This document requires familiarity with RFID technology. It is intended for people in charge of
installing and using the product.
Conventions
Symbol
Meaning
CAUTION: A note that advises users that a specific action could result in the loss of data or
damage the hardware.
WARNING: A note that advises users that a specific action may result in physical harm.
A note that provides additional information that helps the user perform a task or obtain the
best performance from the product.
Abbreviations and Acronyms
AFI
Application Family Identifier
AON
All Or None
API
Application Programming Interface
ASK
Amplitude Shift Keying
CPU
Central Processing Unit
CRC
Cyclic Redundancy Check
DLL
Dynamic-Link Library
DPU
Digital Processing Unit
DSFID
Data Storage Format Identifier
DSP
Digital Signal Processor
EAS
Electronic Article Surveillance
ETX
End of Text
HPI
Host Port Interface
I/O
Input/Output
IFD
Interface Device
LED
Light Emitting Diode
Medio P101-WIFI
LSB
Least Significant Bit
MSB
Most Significant Bit
OS
Operating System
PC
Personal Computer
PCB
Printed Circuit Board
RAM
Random Access Memory
RF
Radio Frequency
RFID
Radio Frequency IDentification
RFU
Reserved for Future Use
RPU
Radio Processing Unit
RTC
Real Time Clock
RTF
Reader Talks First
SAM
Security Access Module
STX
Start of Text
TTF
Tag Talks First
TTL
Transistor-Transistor Logic
TTY
TeleTYpe
UID
Unique Identifier
Glossary
Anti-Collision Tag capability making it readable while other tags are present in the RF field.
Antenna An aerial that receives and/or transmits radio frequency signals. Aerials are
manufactured in a variety of forms, shapes and sizes.
Baud A unit of measure of data transmission speed representing the number of signal changes per
second.
BNC Connector Cylindrical metal connector with a copper core that is located at the tip of a
coaxial cable, and is used to connect cables together. It attaches by pushing and twisting the outer
cylinder on to two locking pins.
Coupler See Reader.
Data Storage Format Identifier Identifies the structure of the data stored in the tag.
Digital Signal Processor This part of the Radio Processing Unit (RPU) performs real-time tag
decoding and manages the Medio L200 configuration.
Dynamic-Link Library Executable routines that are stored as separate files with DLL extensions
and executed only when needed by the program.
Host Port Interface Interface used to access the DSP memory.
IEC Connector Three-pin connector used on sockets that carry mains electricity to the computer.
All PCs use a male IEC connector and mains lead with a female IEC connector.
Interrogation Pulse A signal transmitted by the coupler to activate the tag’s transponder.
4/42
Revision 1.0
February 2006
Read This First
Monitoring Port Parallel Port granting access to the HPI. It communicates directly with the Radio
Processing Unit
Multi-Read See Anti-Collision
Nibble Half a byte (4 bits)
Packaged Reader A reader in its casing.
Phase Shift Difference of phase between the 13.56 MHz field emitted by two antennas. This
feature is dedicated to rotating field applications and three-dimensional volume tag detection.
Protocol A set of rules governing a particular function, such as the flow of data/information in a
communication system (communication between a tag and a reader or a reader and a PC or host
computer).
Radio Frequency Identification System (RFID) An automatic identification and data capture
system comprising one or more readers and one or more tags in which data transfer is achieved by
means of suitable modulated inductive or radiating electromagnetic carriers.
Radio Processing Unit This unit controls the main features of the Medio L200, such as the RF
channels, the multiplexer and the tag decoding.
Reader Electronic system for the communication between tags and host computers.
Reader Talks First Chip protocol for exchanges between the reader and the chip, whereby the
chip waits for a command from the reader to which it responds.
RS-232 Electronic Industries Association (EIA) standard for serial interfaces between computers
and peripherals which defines the function, the electrical characteristics and the timing of signals.
RS-485 Electronic Industries Association (EIA) standard for multipoint, differential data
transmission. It allows multiple nodes to communicate bi-directionally over 1 or 2 twisted pairs.
Smart Label See Tag
Tag Small, flexible label from the 13.56 MHz TAGSYS product line. A tag is made of a chip
connected to an etched antenna.
Tag Talks First Chip protocol for exchanges between the reader and the chip, whereby the tag
sends information continuously, without waiting for a specific command from the reader.
Transceiver A combined transmitter and receiver.
Transponder A combined receiver/transmitter that automatically transmits a signal when a ‘trigger’
is received by it. The trigger is often a pulse, called an interrogation pulse.
Wi-Fi (or Wi-fi, WiFi, Wifi, wifi) is a set of product compatibility standards for wireless local area
networks (WLAN) based on the IEEE 802.11 specifications. New standards beyond the 802.11
specifications, such as 802.16(WiMAX), are currently in the works and offer many enhancements,
anywhere from longer range to greater transfer speeds.
February 2006
Revision 1.0
5/42
Medio P101-WIFI
If you need assistance
Please contact your nearest TAGSYS sales representative or the TAGSYS welcome desk at:
Telephone:
+33 (0)4 91 27 57 00
Fax:
+33 (0)4 91 27 57 01
E-Mail:
info@tagsys.net
Website:
http://www.tagsysrfid.com/
Contact for Comments
We welcome your feedback to help us provide high quality documentation.
For technical comments, please contact our welcome desk:
Telephone:
Fax:
E-Mail:
+33 (0)4 91 27 57 00
+33 (0)4 91 27 57 01
info@tagsysrfid.com
Please remember to quote the Document Reference Number DOC12070A0, your job title and your
company.
Quality Issues
TAGSYS implements stringent quality controls at all stages of its manufacturing process. However,
should you find a defect with this product, please notify your TAGSYS Quality Service
representative using the dedicated Product Return Form.
Telephone:
Fax:
6/42
+33 (0)4 91 27 57 36
+33 (0)4 91 27 57 02
Revision 1.0
February 2006
Read This First
Table of Contents
Publishing Information________________________________________________________________ 2
Disclaimer and Limitation of Liability _________________________________________________________ 2
Read This First _______________________________________________________________________ 3
Audience___________________________________________________________________________________ 3
Conventions _______________________________________________________________________________ 3
Abbreviations and Acronyms ________________________________________________________________ 3
Glossary ___________________________________________________________________________________ 4
If you need assistance ______________________________________________________________________ 6
Contact for Comments ______________________________________________________________________ 6
Quality Issues ______________________________________________________________________________ 6
For Your Safety ___________________________________________________________________ 9
1.1
General Use___________________________________________________________________________ 9
1.2
Care and Maintenance _________________________________________________________________ 9
1.3
Important Safety Information __________________________________________________________ 10
1.3.1
Certification _____________________________________________________________________ 11
2.1
Occupational Health __________________________________________________________________ 11
2.2
Regulatory Notices ___________________________________________________________________ 11
2.2.1
2.2.2
2.2.3
3.1
Product Description __________________________________________________________________ 13
3.2
Medio P101-WIFI Key Features ________________________________________________________ 13
3.3
Delivery _____________________________________________________________________________ 14
Installing the Reader _____________________________________________________________ 15
Reader Connections __________________________________________________________________ 15
4.1.1
4.1.2
4.2
4.3
Front Panel__________________________________________________________________________________ 15
Rear Panel __________________________________________________________________________________ 17
Communicate with WIFI Interface ______________________________________________________ 18
4.2.1
4.2.2
4.2.3
WIFI Module Description ______________________________________________________________________ 19
Default Reader Network Settings _______________________________________________________________ 21
ADDP procedure (Advanced DigiConnect Discovery Device)_______________________________________ 22
Communicate with the USB Interface __________________________________________________ 24
4.3.1
4.3.2
Window 98® USB Drivers Installation ___________________________________________________________ 24
Windows XP USB Drivers Installation ___________________________________________________________ 25
Px Explorer ______________________________________________________________________ 26
5.1
Installing Px Explorer _________________________________________________________________ 26
5.2
Running Px Explorer _________________________________________________________________ 28
5.2.1
5.2.2
In Europe (EC and RTTE Directives)____________________________________________________________ 11
In USA (FCC Directive) _______________________________________________________________________ 12
In Canada___________________________________________________________________________________ 12
Introduction _____________________________________________________________________ 13
4.1
Operating Environment _______________________________________________________________________ 10
USB Communication _________________________________________________________________________ 28
WIFI Communication _________________________________________________________________________ 28
5.3
Reading and Writing a Tag ____________________________________________________________ 29
5.4
Downloading a firmware ______________________________________________________________ 30
Stand-alone Mode ________________________________________________________________ 32
February 2006
Revision 1.0
7/42
Medio P101-WIFI
6.1
Stand-alone Mode Features ___________________________________________________________ 32
6.1.1
6.1.2
6.1.3
6.1.4
6.2
Stand-alone Mode Settings____________________________________________________________ 34
6.2.1
6.3
Customized ASCII Message Format ____________________________________________________________ 33
Repetition Option ____________________________________________________________________________ 33
Trigger Input_________________________________________________________________________________ 34
Output Settings ______________________________________________________________________________ 34
Using Px Explorer ____________________________________________________________________________ 35
Disabling Stand-alone Mode___________________________________________________________ 35
Connecting Peripheral Devices____________________________________________________ 36
7.1
Using the Universal Input pin__________________________________________________________ 36
7.2
Using the Universal Output pin ________________________________________________________ 36
7.2.1
7.3
Output Wiring________________________________________________________________________________ 36
I/O Electrical Signal Requirements _____________________________________________________ 37
Technical Specifications __________________________________________________________ 38
Electrical Characteristics _________________________________________________________ 39
9.1
Absolute Maximum Ratings ___________________________________________________________ 39
9.2
DC Characteristics ___________________________________________________________________ 39
10
Warranty Conditions ____________________________________________________________ 40
10.1
Warranty ___________________________________________________________________________ 40
10.2
Warranty Exclusions________________________________________________________________ 40
10.2.1
10.2.2
8/42
General Provisions ___________________________________________________________________________ 41
How to Return Defective Products ______________________________________________________________ 41
Revision 1.0
February 2006
For Your Safety
1 For Your Safety
1.1 General Use
The Medio P101-WIFI is designed to be reliable and to provide years of trouble-free service.
Please observe the following general tips:
ƒ
Take care not to scratch the device. Keep the device clean. When working with the device,
use only TAGSYS-approved accessories.
ƒ
This device is not waterproof and should not be exposed to rain or moisture. Under extreme
conditions, water may enter the circuitry.
ƒ
Protect the device from extreme temperatures. For example, do not place the device in a
windowed area where the sun may cause extreme temperatures, and keep it away from
heaters and other heat sources.
ƒ
Do not store or use the device in any location that is extremely dusty, damp, or wet.
ƒ
Use a soft, damp cloth to clean the device. If the surface of the device becomes soiled,
clean it with a soft cloth moistened with a diluted window-cleaning solution.
1.2 Care and Maintenance
This device is a product of superior design and should be handled with care. The suggestions
below will further increase the lifetime of this device.
•
Keep the device and all parts and accessories out of the reach of small children.
•
Keep the device dry. Precipitation, humidity and liquids contain minerals that will corrode
electronic circuits.
•
Do not use or store the device in dusty, dirty areas. Its moving parts can be damaged.
•
Do not store in hot areas. High temperatures can shorten the life of electronic devices,
damage batteries and warp or melt certain plastics.
•
Do not store in cold areas. When the device warms up (to its normal temperature), moisture
can form inside the device, which may damage electronic circuit boards.
•
Do not attempt to open the device. Non-professional handling of the device may damage it.
•
Handle the device with care. Shocks may break internal circuit boards.
•
Do not clean the device with harsh chemicals, cleaning solvents or strong detergents.
Gently wipe the device with a soft cloth slightly dampened in a mild soap-and-water
solution.
•
Do not paint the device. Paint may clog the device’s moving parts and prevent proper
operation. Paint with metallic contents may limit device performances.
•
If the device or any accessory are not working properly, take it to your nearest qualified
TAGSYS representative.
February 2006
Revision 1.0
9/42
Medio P101-WIFI
1.3 Important Safety Information
1.3.1 Operating Environment
When connecting the device or any accessory to another device, read its user’s guide for detailed
safety instructions. Do not connect incompatible products.
As with all RF equipment, users are advised that the equipment should only be used in its normal
operating position.
10/42
Revision 1.0
February 2006
Certification
2 Certification
2.1 Occupational Health
TAGSYS Medio P101-WIFI reader has been designed and tested to be in conformity with the
European Standard EN 50364 “Limitation of human exposure to electromagnetic fields from
devices used in Electronic Article Surveillance (EAS), Radio Frequency Identification (RFID) and
similar applications” in conjunction with the European Standard EN 50357 describing how to
evaluate the exposure level.
2.2 Regulatory Notices
An RFID system typically composed of an RF emission device such as the Medio P101-WIFI
connected to an antenna is subject to national regulations that may differ by country.
One important item to consider is the maximum permissible magnetic field intensity at a distance of
10 meters from the antenna that must not exceed 42 dBµA/m in Europe and 38 dBµA/m in US.
The Medio P101-WIFI meets these limits.
2.2.1 In Europe (CE and RTTE Directives)
The Medio P101-WIFI (connected to L-W1 or TR-HA1or LSA3 or Aero LI antenna) complies with
the European EMC directive. (CE Declaration of Conformity granted)
The Medio P101-WIFI (connected to L-W1 or TR-HA1or LSA3 or Aero LI antenna) complies with
the requirements of the Telecommunication Terminal Equipment Act (FTEG) and the RTTE
Directive 1995/5/CE.
It is the responsibility of the TAGSYS Reseller to install the Medio P101-WIFI as described in this
User’s Guide or TAGSYS Documentation.
Any modification of the Medio P101-WIFI is prohibited without the written consent of TAGSYS.
Unauthorized modification may void the conformity of the equipment to CE and RTTE Directives
and will void the TAGSYS warranty.
It is the responsibility of the CIT (Certified Integrators by TAGSYS) to install the Medio P101WIFI as described in this User’s Guide or in TAGSYS Documentation.
If the Medio P101-WIFI is further integrated in a different product, it is the responsibility of
the manufacturer of this complementary product to obtain the required approvals for this
product.
February 2006
Revision 1.0
11/42
Medio P101-WIFI
2.2.2 In USA (FCC Directive)
Medio P101-WIFI
WARNING TO USERS IN THE UNITED STATES
FEDERAL COMMUNICATIONS COMMISSION (FCC) RADIO
INTERFERENCE STATEMENT 47 CFR Section 15.105(b)
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and if not installed and used in accordance with the instructions
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
▪
Reorient or relocate the receiving antenna.
▪
Increase the separation between the equipment and receiver.
▪
Connect the equipment into an outlet on a circuit different to that to which the receiver is
connected.
▪
Consult the dealer or an experienced radio/TV technician for help.
NO UNAUTHORIZED MODIFICATIONS
47 CFR Section 15.21
CAUTION: This equipment may not be modified, altered, or changed in any way without signed
written permission from TAGSYS SA. Unauthorized modification may void the equipment
authorization from the FCC and will void the TAGSYS warranty.
ANTENNA REQUIREMENT
47 CFR Section 15.203
CAUTION: This equipment must be professionally installed. The installer shall be responsible for
ensuring that the proper antenna is employed so that the limits in this part are not exceeded. Nonprofessional installation or installation of the equipment with an improper antenna may void the
equipment authorization from the FCC and will void the TAGSYS warranty.
The Medio P101-WIFI (equipped with L-W1 and TR-HA1 antennas) has been designed to comply
with FCC 47 CFR Part 15 Rules.
Operation is subject to the following two conditions: (1) The system devices may not cause harmful
interference, and (2) The library system devices must accept any interference received, including
interference that may cause undesired operation.
2.2.3 In Canada
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel
brouilleur du Canada.
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations
12/42
Revision 1.0
February 2006
Introduction
3 Introduction
3.1 Product Description
The Medio P101-WIFI is a Medium Range 13.56 MHz RFID reader designed for Library, Textile
Rental and I&L applications. The Medio P101-WIFI has been designed to be used in combination
with L-W1 and TR-HA1 antennas that comply with FCC and CE rules and L-SA3 and Aero-LI
antennas that comply with CE rules. The Medio P101-WIFI can decode C210, C220, C240, C320,
C370(ISO 15693), C270(I-Code1)and I-Code ePC and I-Code UID tags.
Due to its small size, the Medio P101-WIFI can be used either in desktop configuration or easily
integrated in self check stations.
The Medio P101-WIFI is equipped with the following communication interfaces:
•
•
USB 1.1 communication link (prioritary)
WIFI (Raw TCP serial communication)
3.2 Medio P101-WIFI Key Features
Table 1: Medio P101-WIFI Key Features
Description
Medio P101-WIFI
Operating Frequency
Compatibility
(depends on application
firmware)
Serial Link
13.56 MHz
Firmware
Chips
Library
C220, C320, C370(ISO 15693)
Textile
rental
C210, C240, C270(Philips I
Code1), C370(ISO15693)
I&L
C270 (Philips I-Code1), C370
(ISO15693), I-Code EPC/ICode UID
USB 1.1 or WIFI raw TCP serial
communication
Firmware Downloadable
February 2006
Yes
Revision 1.0
13/42
Medio P101-WIFI
3.3 Delivery
The Medio P101-WIFI Tag Reader kit contains the following items:
Table 2: Package Contents
Quantity
Item
Medio P101-WIFI reader
WIFI antenna
SMA/BNC adaptor
Set of rubber feet
USB cable
I/O connector
Wall fixing accessory
12 V power supply
CD-ROM including:
14/42
•
Medio P101-WIFI User’s Guide, Command Set
•
USB drivers for Win32 X86 platforms
•
User-friendly Px Explorer software provided for test and debug operations on
Windows® 9x, NT®, 2000 and XP platforms
•
TAGSYS Software Development Kits including
o Medio STX Dll package
o Library SDK including Dlls and ActiveX control
o Java Package
•
Digiconnect WIFI module integration kit
•
Adobe Acrobat reader version 6&7
Welcome Letter / Product Return Form
Revision 1.0
February 2006
Installing the Reader
4 Installing the Reader
This section describes how to install the Medio P101-WIFI reader.
4.1 Reader Connections
4.1.1 Front Panel
The front panel is dedicated to RF and I/O connectors:
Red Led
Figure 1: Front panel
RF antenna
connector
I/O
connector
•
Green Led
RF antenna connector:
Any of the following antennas can be connected to the standard SMA connector:
Antennas that apply to FCC&CE rules
Antennas that apply to CE rules
•
L-W1
•
Aero LI
•
TR-HA1
•
L-SA3
WIFI antenna cannot be plugged to RF connector (plugs don’t match)
February 2006
Revision 1.0
15/42
Medio P101-WIFI
•
Leds
The red LED lights on or blinks when the reader is ready to communicate with the host system and
acts as follow:
Power supply
voltage
Value
RF capability
< 5.20 V
5.2 V < x < 6.9 V
7 V < x < 8.9 V
9.0 V < x < 10.2 V
> 10.3 V
Insufficient
Low
Medium
High
No
Degraded
Correct
Red LED status
off
Fast blinking
Fast blinking
Slow blinking
On
During firmware downloading the red Led is blinking.
Operating voltage range fits with a correct RF capability.
The green Led is turned on when the output I/O connector is active.
•
I/O connector
#1
#3
#5
#2
#4
Table 2: J3 Wiring
Pin number
16/42
Signals
Output
Supply output (12V with 470 Ω serial resistor)
Universal input
Ground
Ground
Revision 1.0
February 2006
Installing the Reader
4.1.2 Rear Panel
The rear panel is dedicated to power supply and communication connectors.
Figure 3: Rear panel
WIFI antenna
WIFI module
12V DC
Power supply
USB
connector
connector
Reset button for
WIFI module
•
Power Supply Connector J2
2.5mm Jack type (positive connection on the center pin)
•
WIFI module connector
Reverse polarity SMA connector for WIFI antenna (Please see Chapter 4.2, for more details)
•
Reset button
Reset button only used for WIFI module (Please see Chapter 4.2 for more details)
•
USB connector
USB connector type B
February 2006
Revision 1.0
17/42
Medio P101-WIFI
Before you power the reader up you must plug the WIFI antenna provided with the Medio
P101-WIFI product
This FCC Part 15 radio device operates on a non-interference basis with other devices
operating at this frequency when using the supplied antenna. Any changes or modification to
this product not expressly approved by TAGSYS could void the user’s authority to operate
the device.
When USB communication link is active (plugged and powered) the WIFI module is turned
off.
You cannot connect any RF antennas to this connector (plugs don’t match)
4.2 Communicate with WIFI Interface
Preliminary checking:
USB cable must be unplugged to ensure that the WiFi Module is turned on
WiFi antenna must be correctly connected to the rear panel
The embedded WiFi module is the DigiConnect Wi-ME. Any information on this module is available
on the CDROM in the directory “\DigiConnect IntegrationKit\Documentation” or on the DigiConnect
WEB pages at “www.digi.com”.
Please read the DigiConnect User’s Guide to have an overview of the module characteristics.
The following explanations will give you the first steps to run the reader. Advanced functionalities
can be found in the DigiConnect User’s Guide.
18/42
Revision 1.0
February 2006
Installing the Reader
4.2.1 WIFI Module Description
•
Characteristics
Parameter
Value
Standard
IEEE 802.11b
Frequency
2.4 GHz
Data Rate
Up to 11 Mbps with automatic fallback
Modulation
CCK (11/5 Mbps), DQPSK (2 Mbps), DBPSK (1 Mbps)
Transmit Power
16 dBm typical
Receive sensitivity
-82 dBm for 11 Mbps, -92 dBm for 1Mbps
Network Activity LED
Network Link LED
Reset Button
•
LED description
LED
Color
Description
This LED stays on continuously when a WIFI access point is
engaged.
Network Link
Yellow
It blinks when no access point is available after device start
up.
Note that this LED is turned off during device starting up.
Network Activity
February 2006
Green
This LED monitors the network traffic. It turns on when any
traffic is detected.
Revision 1.0
19/42
Medio P101-WIFI
•
Reset Procedure
To reset the WIFI module 2 procedures are available:
Reboot the device: it is used to reinitialize the communication with the access point.
Reset the device to TAGSYS default factory settings: it is used when you can no more
communicate with the reader due to wrong WIFI settings.
Both reset procedures are available by software via the WEB or TELNET interface.
Reset
Reboot
Description
While the reader is supplied, push the reset button with a thin object and
release it. Wait for the reader start up.
This procedure reset the entire device configuration (including network
settings) to the TAGSYS factory defaults.
Reset To
TAGSYS Factory
defaults
20/42
Unplug the reader power supply
Push the reset button
Plug the reader power supply
Keep the reset button pressed until the yellow LED blinks once and
3 times.
Release the reset button
Unplug the power supply and plug it again
Wait for reader start up.
Revision 1.0
February 2006
Installing the Reader
•
RF Exposure Statement
The Medio P101-WIFI module complies with the RF exposure limits for humans as called out
in RSS-102. It exempt from RF evaluation based on its operating frequency of 2.4 GHz, and
effective radiated power less than the 3 watt requirement for a mobile device (>20 cm
separation) operating at 2.4 GHz.
•
Safety Statements
Do not touch or move the WIFI antenna while the unit is transmitting or receiving
Do not hold the reader such that the antenna is very close to or touching the head
(especially face or eyes), while transmitting.
Do not operate a portable transmitter near unshielded blasting caps or in an explosive
environment unless it is a type especially qualified for such use.
4.2.2 Default Reader Network Settings
You will not be able to configure any network setting before the reader is not engaged with your
access point.
It depends to you to engage the reader with your access point correctly first. You should use a
specific network to initialize the reader network accordingly your final network.
The mandatory information you need are the following:
the reader is compliant with IEEE 802.11b. Please check your access point is able to
support this standard (access point configuration “b or g” or “b only”)
SSID of the reader is TAGSYSRFID and the access point must be set accordingly
No encryption is used to communicate with the reader
The SSID and the Encryption status can be changed afterward.
Additionally, the default settings for the reader network configuration are :
DHCP : Off
Static IP Address : 192.168.0.2
Subnet Mask : 255.255.255.0
Default Gateway : 0.0.0.0
SSID : TAGSYSRFID
Available to any wireless network
Country : United States
Channel : Auto-scan
Network Authentication : Open System
Data Encryption : Open System
You can now configure your access point to engage the reader or follow the ADDP procedure to
change the basic network IP settings.
February 2006
Revision 1.0
21/42
Medio P101-WIFI
If you decide to configure your access point to meet the default settings of the reader, you can
check your system is operational by pinging the reader using then “ping 192.168.0.2” MSDOS
command prompt.
4.2.3 ADDP procedure (Advanced DigiConnect Discovery Device)
Firewalls may block ADDP broadcast protocol. Please turn your firewall off for initialization to
avoid issues (This includes Windows XP firewall)
Run “\DigiConnect Integration Kit\dgdiscvr.exe” program available on the product CDROM. The
following window pops up:
If no reader appears in the Discovery windows, check that:
no firewall program is running
the reader is properly engaged with its access point
the access point is properly linked to your PC
If the reader is not properly configured, double-click on the device. The following window pops up:
22/42
Revision 1.0
February 2006
Installing the Reader
Select the correct Static IP, Subnet mask and Default Gateway or check the automatic setting in
case a DHCP protocol is available on your network.
Then, click Save. The reader starts to rebooting and the window closes.
Back to the main window, double-click once again on the device. The WEB interface opens in the
Internet Explorer browser (caution to the proxy settings of your internet browser connection, it must
be set to allow access to this device).
Log on to the configuration WEB page device:
username : root
password : tagsysrfid
Follow DigiConnect WI-ME user’s guide to configure the device.
February 2006
Revision 1.0
23/42
Medio P101-WIFI
4.3 Communicate with the USB Interface
At first connection to the PC USB port, Windows® will detect the TAGSYS Medio P101-WIFI
reader and will ask you for drivers installation. USB drivers are located into the USB Drivers folder
on the product CD-Rom.
Two drivers must be installed:
The first one is the direct driver, which provides direct access to USB device via a dynamic
link library (DLL).
The second one is the virtual COM port (VCP) driver. The VCP driver emulates a standard
PC COM port.
4.3.1 Window 98® USB Drivers Installation
Power up and connect your Medio P101-WIFI to a spare USB port on your PC. This should bring
up a “Building Driver Information Database” followed by the Windows Add New Hardware Wizard.
Click “Next” to proceed with the installation
ƒ
Select “Search for the best driver for your device” and then click “Next”
ƒ
Select “Specify a location” and click the Browse button to select the USB Drivers folder on
the Product CR-Rom. Once the files have been located, click “Next” to proceed with the
installation
ƒ
Click “Next” to install the device
ƒ
Windows® should then display a message indicating that the installation was successful.
Click “Finish” to complete the installation.
To confirm that the installation has completed successfully, open the Device Manager and select
“View devices by type”. The TAGSYS Medio P101 appears as a USB device connected to a USB
port
The next step is to install the VCP drivers.
Power up and connect your Medio P101-WIFI to a spare USB port on your PC. This should bring
up a “Building Driver Information Database” followed by the Windows Add New Hardware Wizard.
24/42
Revision 1.0
February 2006
Installing the Reader
ƒ
Select “Search for the best driver for your device” and then click “Next”
ƒ
Select “Specify a location” and click the Browse button to select the USB Drivers folder on
the Product CR-Rom. Once the files have been located, click “Next” to proceed with the
installation
ƒ
Click “Next” to install the device
ƒ
Windows® should then display a message that the installation of the serial converter driver
was successful. The COM port emulation driver must now be installed. Click “Finish” to
complete the installation.
To confirm that the installation has completed successfully, open the Device Manager and select
“View > devices by type”. The TAGSYS Medio P101 appears as an additional COM port.
4.3.2 Windows XP USB Drivers Installation
Power up and connect your Medio P101-WIFI to a spare USB port on your PC. This will launch the
Windows Found New hardware Wizard
ƒ
Select “No, not this time” and click next to proceed with the installation
ƒ
Select “Install from a list or specific location (Advanced)” and then click “Next”
ƒ
Select “Search for the best driver in these locations” and click the Browse button to select
the TAGSYS USB Drivers folder on the Product CR-Rom. Then click “Next” to proceed.
ƒ
Windows should then display a message indicating that the installation was successful.
Click Finish to complete the installation
To confirm that the installation has completed successfully, open the Device Manager and select
“View > Devices by type”. The TAGSYS Medio P101 appears as a USB device connected to a
USB port.
The next step is to install the VCP drivers.
Power up and connect your Medio P101-WIFI to a spare USB port on your PC. This will launch the
Windows Found New Hardware Wizard
ƒ
Select “No, not this time” and click next to proceed with the installation
ƒ
Select “Install from a list or specific location (Advanced)” and then click “Next”
ƒ
Select “Search for the best driver in these locations” and click the Browse button to select
the USB Drivers folder on the Product CR-Rom. Then click “Next” to proceed.
ƒ
Windows should then display a message indicating that the installation was successful.
Click Finish to complete the installation. This has installed the serial converter. The COM
port emulation driver must be installed after this has completed.
ƒ
After clicking “Finish”, the Found New Hardware Wizard will continue by installing the COM
port emulation driver.
To confirm that the installation has completed successfully, open the Device Manager and select
“View > Devices by type”. The TAGSYS Medio P101 appears as an additional COM port.
When the USB cable is plugged and communication is active, the WIFI module is turned off.
February 2006
Revision 1.0
25/42
Medio P101-WIFI
5 Px Explorer
The Medio P101-WIFI reader is delivered with the Px Explorer software tool intended to easily
setup the reader, test it and perform reading and writing operations according to the antenna and
type of tag to be used. In addition, Px Explorer can display additional information such as the
Product Reference and Firmware version and revision. This section describes how to start with Px
Explorer.
5.1 Installing Px Explorer
To install Px Explorer software, insert the product CD-ROM into the disk drive on your PC and run
the Setup from the Medio P101 - Software Suite\Tools\Px Explorer 1-5-7 folder and click “Next”
Click the “Browse” button if you want to choose a specific installation folder.
26/42
Revision 1.0
February 2006
Px Explorer
Once the correct folder is selected, click “Next”
Click “Next” to start the installation process. A shortcut will be created on your desktop and a
program group will be created in the start menu.
February 2006
Revision 1.0
27/42
Medio P101-WIFI
5.2 Running Px Explorer
5.2.1 USB Communication
Before launching Px Explorer be sure which COM port number is assigned to the TAGSYS Medio
P101-WIFI reader. Open the Device Manager and select “View > Devices by type”.
The COM port number is assigned to the Medio P101.
Power up the Medio P101-WIFI and connect the USB cable to both your PC and the Medio P101WIFI. Run Px Explorer. If the following window is displayed click yes.
Open the Communication Settings window (CTRL+C) and check the type of the media, the COM
port number and the communication speed. The default communication speed for the Medio P101WIFI is 115200 Bauds.
Set the STX setting mode to Fast to increase performances and click OK. Now Px Explorer is
ready to communicate with your Medio P101-WIFI.
5.2.2 WIFI Communication
Before running Px Explorer, be sure that the Medio P101-WIFI module is power up and correctly
engaged with the WIFI access point (or router) connected to the host system network.
Open the communication setting window (CRTL+C) and check that the media type is selected to
Ethernet/WIFI as shown below.
28/42
Revision 1.0
February 2006
Px Explorer
Enter the correct reader IP address.
Check the port number value and change it to the correct value in case the default raw TCP port
value of the Medio P101-WIFI reader has been modified.
Set the STX setting mode to Fast to increase performances and click OK.
5.3 Reading and Writing a Tag
Px Explorer includes a Wizard function used to guide you each step of how to read or program a
tag. We recommend using the Wizard function for users who are not familiar with all Px Explorer
capabilities and features.
Click on the Wizard icon (magic wand) to open the Px Explorer Wizard dialog box.
Select the type of chip from the drop–down menu or place the tag on the antenna and click the
“Detect “ button to automatically detect the tag type.
Select the desired operation (Read or Write) and then click OK. All the necessary windows to
perform the desired action will be automatically displayed on the screen.
February 2006
Revision 1.0
29/42
Medio P101-WIFI
For more details concerning Px Explorer select the info menu and click Help (CTRL+H) to display
the Px Explorer User’s Guide.
5.4 Downloading a firmware
Use Px Explorer to download a new firmware. When a communication is established with the
reader, click on the upgrade firmware button
By default Library firmware is already loaded.
The firmware upgrade can be done either using the USB or WIFI communication interface.
The flasher window pops up. Click on select file and go to the directory “\Medio P101 - Standard
Firmware” on the CDROM or to any other directory containing Medio P101 compatible firmware
(.bin files)
30/42
Revision 1.0
February 2006
Px Explorer
Select the firmware you want to download.
Standard firmwares are:
Firmware
File Name
Key
Library
LF12039xx.bin
Medio P101
Industry and Logistics
(I&L)
LF12040xx.bin
Medio P101
Textile Rental
LF12041xx.bin
Medio P101
Compatible chips
C220
C320
C370 (ISO 15693)
C270 (ICode 1)
C370 (ISO 15693)
EPc
UID
C210
C240
C270 (ICode 1)
C370 (ISO 15693)
Verify the Key of the firmware to be able to download it. Key for standard firmware is “Medio P101”
(with a space character between Medio and P101). For non standard firmware, a key will be
supplied with.
Click on Download button and wait until the download is complete.
February 2006
Revision 1.0
31/42
Medio P101-WIFI
6 Stand-alone Mode
Stand-alone Mode is designed to use the reader without using any command set. While in this
mode, the reader is limited to tag reading.
The reader sends the tag ID to the Host System using ASCII protocol via the Reader-to-Host
interface.
ASCII protocol is used in order to provide hexadecimal data that can be read by a variety of
terminal programs (e.g. Microsoft® HyperTerminal).
6.1 Stand-alone Mode Features
Table 3 lists the available Stand-alone mode features.
Table 3: Available Features in Stand-alone Mode
Features
TR-P101
Customized tag type reading
compatibility
(depending on downloaded
application firmware)
C210
C240
C220
C270 (ICode1)
C320
C370 (ISO15693)
I-Code ePC/I-Code UID
Serial Communication Type
USB 1.1
WIFI (Raw TCP serial communication)
Repetition Option
Available
Customized ASCII message format
STX/ETX Characters
Header String
Chip Description String
ID String (variable length)
End of Message String
Input Trigger
Available
Output for active trigger information
Available
Output for tag reading information
Available
32/42
Revision 1.0
February 2006
Stand-alone Mode
6.1.1 Customized ASCII Message Format
When a tag is read, its data are transmitted to the host in the form of an ASCII character frame.
Optional
Optional
C240
2 to 16 characters
C220
2 to 10 characters
C270
2 to 16 characters
C320
2 to 16 characters
C370 (ISO
2 to 16 characters
15693)
ePC
2 to 24 characters
UID
2 to 10 characters
Optional
Required
End of
Message
String
End of Text
ID
Chip
Description
String
2 to 16 characters

(0x03)
character
TR-P101
C210

(Default)
0 to 16
characters
Size
0 to 16
characters
“TAGSYS-“
Chip name
(Default)
0 to 16
characters

(0x02)
character
Description
Header
String
Start of Text
Table 4: Customized ASCII Message Format (TAGSYS RFID Tag is read)
Optional
Optional
Medio P101-WIFI reader can decode all chips in Stand-alone mode. Only the ID field is retrieved in
the return ASCII message. All other fields are optional. The ID field length is programmable; the
default lengths are given in Table 5.
Table 5: Default ID Field Lengths
Chip Type
Default ID Field Length
C210 chip
16 (Total memory)
C240 chip
16 (Block 0 Page 0)
C220 chip
10 (Lockable memory)
C270 chip
16 (Block 0 and Block 1)
C320 chip
16 (Block 0)
C370 chip (ISO 15693)
16 (UID)
ePC
24 (Block 0 to 11)
UID
10 (UID block 14 to 18)
6.1.2 Repetition Option
The reader constantly attempts to read any chips present in the field. When a chip ID is detected,
the reader can send the information to the host in one of 2 modes:
1. In “Repeated Read” mode, the reader returns a chip’s ID to the host with each successful
read operation.
February 2006
Revision 1.0
33/42
Medio P101-WIFI
2. In “Read Once” mode, the reader only returns the ID of a chip if the previous read
corresponds to a different chip, or if all reading attempts have failed 4 times (this feature
makes it possible to detect a chip’s potential exit out of the field).
6.1.3 Trigger Input
When the trigger capability is enabled, a trigger state is used to start and stop the RF scanning.
The trigger is connected to the input of the reader.
Depending on the reply settings of the trigger, the ASCII message can be sent during the trigger
activity (Repeated Read mode and Read Once mode are available) or at the end of the trigger. In
this last case, a message is always sent to the host system:
ƒ
if a tag has been read, the message contains its ID,
ƒ
if a tag has not been read, the message contains a No Message string (that can be defined)
as shown in Table 6.
Table 6: Customized ASCII Message Format (TAGSYS RFID Tag is not read)
Start of Text
Header String
No Tag Found
String
End of Message
String
End of Text
Description

(0x02)
“TAGSYS-“
(Default)
“????????“
(Default)

(Default)

(0x03)
Size
character
0 to 16
characters
0 to 16
characters
0 to 16
characters
character
Status
Optional
Optional
Required
Optional
Optional
6.1.4 Output Settings
The output of the reader can be used to monitor the trigger activity or the successful reads.
6.2 Stand-alone Mode Settings
Stand-alone Mode can be set in one of two ways while the reader is in Normal Operating mode
•
By using the Px Explorer software provided with the reader
•
By using “Set Stand-alone Mode” command followed by a “Reset Reader” command. For
more information, refer to the Medio P101-WIFI Command Set document.
34/42
Revision 1.0
February 2006
Stand-alone Mode
6.2.1 Using Px Explorer
Run the Px Explorer software. In the Settings menu, select General Reader Settings
Enable
Standalone
mode at next
power on
6.3 Disabling Stand-alone Mode
The Medio P101-WIFI can be reset in Standard mode in one of two ways as described below:
•
Use the Px Explorer software provided with the reader and click Yes when the following
window is displayed
•
Send the 'S' character using a console interface (for example, HyperTerminal).
February 2006
Revision 1.0
35/42
Medio P101-WIFI
7 Connecting Peripheral Devices
7.1 Using the Universal Input pin
The reader input can be driven by a voltage source from 0V up to 25V referring to the input ground.
A relay (open chain transistor, switch…) can also be used to connect the input pin and its ground.
Low level input voltage is defined to be in the range of 0 to 1.5V
High level input voltage is defined to be in the range of 3 to 25V
7.2 Using the Universal Output pin
The output pin is an open drain power transistor that can drive a current up to 6A. When activated,
the power transistor connects the output pin and its ground.
The output transistor is protected against heating and current overload. If an overload happens, the
output stops driving current automatically. The output must be turned off to be re-activated.
7.2.1 Output Wiring
Example: Connecting a LED to the Output
+12V (Input voltage)
Pin 2
Pin 1
36/42
470 Ohms
The LED’s cathode is connected to the
Output pin and its anode to the Output Supply
Pin. Note that the Output supply selector is
configured to deliver 5V to supply the LED.
The internal serial resistor limits the current
delivered to the LED.
Revision 1.0
February 2006
Connecting Peripheral Devices
Example: Connecting a load using an external power
The external power must be less than 25V
Pin 1
Pin 4
7.3 I/O Electrical Signal Requirements
Table 7 provides the electrical DC characteristics.
Table 7: I/O Interface Pins - Electrical Characteristics
Parameters
Conditions
Min.
Typ.
Max.
Unit
Input Voltage Low
Input Voltage High
25
Output Current
February 2006
Revision 1.0
Note
37/42
Medio P101-WIFI
8 Technical Specifications
Table 8: Medio P101-WiFi Technical Specifications
Reference
Size (L x W x H)
Weight
DC power
Medio L-P101
154 x 84 x 38 mm (TOPTEC 154F)
250 g (with WiFi Antenna)
12 VDC +/- 10% Typical
C210
C240
C220 (Folio 20)
C320 (Folio 320)
ISO 15693 (Folio 370)
I-Code ePC
I-Code UID
Chip compatibility (depending on
downloaded firmware type)
USB 1.1
WIFI (IEEE 802.11b)
Communication interface
RF Output Power
1.2 W Typical
Power consumption
4.5 W
Operating temperature
0° to +55°C
Storage temperature
-20° to +70°C
Mechanical fixation
Accessories for TOPTEC 154F boxes (Manufacturer : OKW)
Conformity
ETSI 300-330 European Radio compliance
EN 50364
FCC part 15 in combination with TR-HA1 and L-W1 antennas
Communication protocol
38/42
TAGSYS-specific STXE-2
Revision 1.0
February 2006
Electrical Characteristics
9 Electrical Characteristics
This chapter provides information about AC and DC characteristics for all pins. It also gives timing
characteristics for the different interfaces.
9.1 Absolute Maximum Ratings
Parameter
Value
Ambient Operating Temperature
0°C to +55°C
Storage Temperature
-20°C to +70°C
Supply Voltage with respect to GND
25 V
Total Power Dissipation
4.5 W
Total Power Dissipation on Antenna
1.2 W
9.2 DC Characteristics
Value
Description
Max. Typ. Min. Unit
VSupply
Supply Voltage
IRFOff
Supply Current – RFOff – USB Plugged (VSupply =
12V)
IRFOn
Supply Current ( RFOn, Dummy Load
50Ohm, VSupply = 12V)
Supply Current
IRFOn
(RFOn, VSupply = 12V, Antenna connected,
WIFI Communication)
13.2
12
10.8
50
45
40
mA
USB
273
WIFI
383
TR-HA1
383
mA
L-W1
393
mA
LSA-3
384
mA
352
mA
mA
Supply Current
IOpen
(RFOn, No connection on RF Connector, WiFi
Communication)
TOp
Operating Tempature
VUSB
Supply Voltage on USB cable
5.25
IUsb
Supply Current on USB cable
UVOH
D+/D- Static Output high
UVOL
55
°C
4.35
340
µA
3.6
2.8
D+/D- Static Output low
0.3
UVSE
Single Ended Rx Threshold
2.0
0.8
UVCOM
Differential Common Mode
2.5
0.8
UVDIF
Differential Input sensitivity
0.2
ZDRV
Driver Output impedance
44
29
Ohm
Input Voltage Low
Input Voltage High
25
Output Current
February 2006
Revision 1.0
39/42
Medio P101-WIFI
10 Warranty Conditions
10.1 Warranty
TAGSYS warrants that this Product shall comply with the functional specifications set forth herein
for a period of one year from the date of delivery to the Buyer.
This warranty is valid for the original Buyer of the Product and is not assignable or transferable to
any other party.
TAGSYS cannot be responsible in any way for, and disclaims any liability in connection with the
operation or performance of:
ƒ
any product in which the Product is incorporated;
ƒ
any equipment not supplied by TAGSYS which is attached to or used in connection with the
Product; or
ƒ
the Product with any equipment
This warranty does only cover the Product to the exclusion of any such other equipment.
Optimal operation and performance of the Product are obtained by using TAGSYS’ readers, by
applying TAGSYS installation guidelines and by having your installation reviewed by a TAGSYS’
technical consultant.
TAGSYS warranty does not cover the installation, maintenance or service of the Product and is
strictly limited to the replacement of Products considered as defective by TAGSYS and returned
according to the return procedure defined below; in such case, TAGSYS will, at TAGSYS’ option,
either replace every defective Product by one new Product or refund the purchase price paid by
Buyer to TAGSYS for the defective Product.
10.2 Warranty Exclusions
ƒ
Defects or damages resulting from storage of the Product under conditions which do not
comply with TAGSYS specifications or normal usage
ƒ
Defects or damages resulting from use of the Product in abnormal conditions (abnormal
conditions being defined as any conditions exceeding the ones stated in the product
specifications).
ƒ
Defects or damages from misuse, accident or neglect.
ƒ
Defects from improper testing, operation, maintenance or installation.
ƒ
Defects from alteration, modification except modifications or adjustments specifically described
in this Product reference guide, adjustment or repair, or any attempt to do any of the foregoing,
by anyone other than TAGSYS.
ƒ
Any action on Product that prevents TAGSYS from performing an inspection and test of the
Product in case of a warranty claim.
ƒ
Tampering with or abuse of the Product.
ƒ
Any use or incorporation by the Buyer or a third party of TAGSYS' Product into life saving or life
support devices or systems, or any related products, TAGSYS expressly excludes any liability
for such use.
40/42
Revision 1.0
February 2006
Warranty Conditions
10.2.1 General Provisions
This warranty sets forth the full extent of TAGSYS responsibility regarding the Product.
In any event, TAGSYS warranty is strictly limited to (at TAGSYS’ sole option) the replacement or
refund of the Products purchase price to TAGSYS, of Products considered as defective by
TAGSYS.
The remedy provided above is in lieu and to the exclusion of all other remedies, obligations or
liabilities on the part of TAGSYS for damages, whether in contract, tort or otherwise, and including
but not limited to, damages for any defects in the Products or for any injury, damage, or loss
resulting from such defects or from any work done in connection therewith or for consequential
loss, whether based upon lost goodwill, lost resale profits, impairment of other goods or arising
from claims by third parties or otherwise.
TAGSYS disclaims any explicit warranty not provided herein and any implied warranty, guaranty or
representation as to performance, quality and absence of hidden defects, and any remedy for
breach of contract, which but for this provision, might arise by implication, operation of law, custom
of trade or course of dealing, including implied warranties of merchantability and fitness for a
particular purpose.
10.2.2 How to Return Defective Products
The Buyer shall notify TAGSYS of the defects within 15 working days after the defects are
discovered.
Defective Products must be returned to TAGSYS after assignment by a TAGSYS Quality
Department representative of an RMA (Return Material Authorization) number. No Products shall
be returned without their proof of purchase and without the acceptance number relating to the
return procedure.
All Products shall be returned with a report from the Buyer stating the complete details of the
alleged defect.
Call +33 4 91 27 57 36 for return authorization and shipping address.
If returned Products prove to be non-defective, a charge will be applied to cover TAGSYS’ analysis
cost and shipping costs.
If the warranty does not apply for returned Products (due to age, or application of a warranty
exclusion clause), a quote for replacement will be issued, and no replacement will be granted until
a valid purchase order is received. If no purchase order is received within 30 days after the date of
TAGSYS quote, TAGSYS will return the products and charge the analysis cost and shipping costs.
All replaced Products shall become the property of TAGSYS.
The Product Return Form is included on the following page. This form should accompany any
product you need to return to TAGSYS for analysis in the event of a problem.
February 2006
Revision 1.0
41/42
Medio P101-WIFI
Product Return Form
Customer Profile:
Company: ................................................................
Address:...................................................................
.................................................................................
.................................................................................
City & State:.............................................................
Zip Code: .................................................................
Country: ...................................................................
Contact Name: .......................................................
Contact e-mail: ......................................................
Contact Phone: ......................................................
Contact Fax:...........................................................
Order identification:
Product Name:.........................................................
Order Number (OEF):..............................................
Invoice Number: .....................................................
Return Quantity: ....................................................
Order identification:
Product Name:.........................................................
Order Number (OEF):..............................................
Reason for return:
……………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………
To inform TAGSYS of this return, please email it to
RMA@tagsys.net
Address to ship the product with this document attached:
TAGSYS
QUALITY DEPARTMENT
180, chemin de Saint Lambert
13821 La Penne sur Huveaune France
To inform TAGSYS of this return, please also fax it to your Customer Service Representative
+33 4-9127-5701
Return Procedure
The product returned will go through stringent quality controls.
A final analysis report will be sent to you as soon as possible.
Please contact your Quality Service representative for further details at
+33 (0) 4 91 27 57 36
42/42
Revision 1.0
February 2006

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 42
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:dda3536c-e690-42c8-8c19-72718338865c
Producer                        : Acrobat Distiller 6.0 (Windows)
Create Date                     : 2006:03:03 17:04:49+01:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2006:03:03 17:04:49+01:00
Document ID                     : uuid:4c2bb508-35d0-49d4-ad69-cff4d31e9abe
Format                          : application/pdf
Creator                         : plecire
Title                           : Microsoft Word - Medio P101-WIFI User Guide_1.0.doc
Author                          : plecire
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QHKMEDIOP101WIFI

Navigation menu