User manual
AG-300 Plus2 Gateway Operation Manual Copyright Š 2017, All Rights Reserved. Ver: R01 D/C: 106-1121 Federal Communications Commission (FCC) Statement Statement shall be listed in the label (if the product is smaller than palm size, it could be listed in user manual for instead.) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference and 2) this device must accept any interference received, including interference that may cause undesired operation of the device. Statement shall be listed in the manual 15.21 You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the userâs authority to operate the equipment. 15.105(b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference and 2) this device must accept any interference received, including interference that may cause undesired operation of the device. FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters from your body. USB Port only connection Vibration gauge (VB-200STU) Tecom AG-300 Plus2 IoT Gateway Operation Manual Table of contents Overview ............................................................................................................................................ 3 AG-300 Plus2 Configuration ........................................................................................................ 5 1. System structure .............................................................................................................. 5 2. Equipment wiring ............................................................................................................ 5 3. RS485 wiring ..................................................................................................................... 7 4. Power bank wiring........................................................................................................... 8 5. Equipment dimension .................................................................................................... 8 6. AG-300 Plus2 view........................................................................................................... 9 Equipment setup............................................................................................................................10 1. Network setup................................................................................................................10 2. Account setup.................................................................................................................12 3. VB200 setup ....................................................................................................................14 4. Wireless setup ................................................................................................................17 4.1 The wireless AP mode configuration (WiFi mode setup) .........................17 4.2 WiFi mode setting................................................................................................22 5. Hardware setup..............................................................................................................26 APP software operation...............................................................................................................27 Tecom AG-300 Plus2 IoT Gateway Operation Manual Overview Tecom smart portable vibration diagnosis instrument is one of the most innovative mobile maintenance products in the world. By making the most of IoT, sensor, and management software technology it is designed to measure vibration of running E&M equipment without extra power cord or network cable. With fully PnP based convenience, it is ideal for small and medium size manufacturers and enterprises in pursuing productivity 4.0. Featuring IoT WiFi gateway (AG-300 Plus2), integrated vibration gauge VB-200STU, IR temperature sensor, power bank, and iOS and Android platform available diversified smartphone APP (which can be downloaded, installed, and used immediately), Tecom smart portable vibration diagnosis instrument system is ideal for equipment installation or maintenance engineers for measuring temperature and vibration at equipment power contact, E&M, rotary machinery, and motor on the spot. In addition, it combines measurements made on site with interactive analysis and diagnosis of the system to provide instant, helpful, and effective target E&M equipment health analysis which, in turn, not only enable easy manufacturing E&M equipment management and upkeep in healthy status but also prevent hazardous system shutdown from happening. Tecom smart portable vibration diagnosis instrument may connect up to 4 vibration gauges for multiple diagnosis at the same time. With a breakthrough in vibration measurement concept, it integrates vibration measurement, analysis, and diagnosis operation in one portable device to save working hours and reduce onsite maintenance and repair time significantly. Tecom smart portable vibration diagnosis instrument system may help acquiring full first commissioning operation data that is critical for later maintenance and big data analysis for manufacturer in future product release. Tecom AG-300 Plus2 IoT Gateway Operation Manual In situ and instant vibration diagnosis information Productivity 4.0 Tecom AG-300 Plus2 IoT Gateway Operation Manual AG-300 Plus2 Configuration 1. System structure Target E&M Tecom smart portable Vibration Mobile communication gateway AG-300 Plus 2 Motor Fan VB-200STU Compressor (Built-in WiFi) VB-200STU Pump Power bank Generator Installation 2. IR temperature sensor Measurement Analysis Diagnosis Report Equipment wiring Open portable vibration diagnosis instrument carrying case and belt, and connect them according to wiring diagram shown below. A. Connect AG-300 Plus2 to VB-200STU with RS485(1/2) B. Connect AG-300 Plus2 DC Jack to power bank to the power cord C. WiFi connect smartphone to built-in WiFi router of AG-300 Plus2 D. Mount (magnetic) vibration gauge to target equipment according to its installation guidelines Tecom AG-300 Plus2 IoT Gateway Operation Manual AG-300 Plus2 e-Gateway B RS485 Power bank RS485#4 RS485#3 RS485#2 RS485#1 B-1 Vibration gauge VB-200STU B-2 Vibration gauge VB-200STU B-3 Vibration gauge VB-200STU Optional B-4 Vibration gauge IR Temp. Sensor VB-200STU accessories, Once wired according to aforementioned diagram, your smartphone is now ready to execute test, analysis, and diagnosis over target equipment with the "vibration diagnosis" APP; follow the following diagram and steps E~F for computer and the Internet connection as required. E. Connect AG-300 Plus2 WAN port (blue) and LAN port of ADSL modem with network cable F. Connect AG-300 Plus2 LAN port (yellow) and PC with network cable (for system setup only) Tecom AG-300 Plus2 IoT Gateway Operation Manual AG-300 Plus2 The Internet e-Gateway B RS485 Comput 3. ADSL modem RS485 wiring (1) AG-300 Plus2 E-gateway AG-300 Plus2 supports up to 4 vibration gauge with RS485 (USB) connection as shown in figure below: RS485 (USB) set 1 RS485 (USB) set 2 RS485 (USB) set 3 RS485 (USB) set 4 VB-200STU VB-200STU Reserved Reserved (2) VB-200STU This portable vibration diagnosis instrument comes with 2 built-in vibration gauges VB-200STU; featuring integrated RS485 cable and USB connector the latter may direct connect to e-gateway AG-300 Plus2 as shown inthe figure below: Tecom AG-300 Plus2 IoT Gateway Operation Manual Magnetic vibration gauge RS485(USB) VB-200STU Target E&M AG-300 Plus2 equipment (motor) 4. VB-200STU vibration gauge Power bank wiring This portable vibration diagnosis instrument comes with power bank power cord, please connect DC Plug to DC jack of AG-300 Plus2 and USB connector to USB port in power bank as shown in figure below: e-gateway AG-300 Plus2 DC power plug Power bank power cord 5. Power bank USB Equipment dimension AG-300 Plus2 dimension: 130mm (length) x 90mm (width) x 36 mm (height) Tecom AG-300 Plus2 IoT Gateway Operation Manual 6. AG-300 Plus2 view Tecom AG-300 Plus2 IoT Gateway Operation Manual Equipment setup 1. Network setup Step 1 - Keep your PC / NB and e-gateway AG-300 Plus2 in the same LAN segment (better have DHCP enabled on your PC / NB) - Connect PC/NB and AG-300 Plus2 (LAN port) with Ethernet cable - Connect power adaptor to AG-300 Plus2 - Open a browser on the connection, input AG-300 Plus2 setup page address http://192.168.168.10 - Input user name: admin - Input password: IP585xAdmin - Click OK Tecom AG-300 Plus2 IoT Gateway Operation Manual Step 2 (Skip this step for DHCP PnP network) - In main menu on the left, click [Settings] [WAN]. - In WAN connection type dropdown menu, select [STATIC (Fixed IP)] - IP address: input IP data. - Subnet mask: input subnet mask data. - Default gateway: input default gateway data. - Primary DNS server: input main DNS server data. - Secondary DNS serverinput secondary DNS server. - Click the [Apply] button at bottom of page once all settings were made successfully. Try connecting to popular web sites (e.g., edition.cnn.com and www.yahoo.com.tw to validate external networking function Set smartphone APP communication port to TCP 53100 ~53199 in case firewall management service is in existence. Tecom AG-300 Plus2 IoT Gateway Operation Manual 2. Account setup Step 1 In main menu on the left, click [Settings] [Unit pairing] before selecting [Add] button. Step 2 Check the [Select] column before selecting the [Edit] button Tecom AG-300 Plus2 IoT Gateway Operation Manual - Name : input user name. - Account : e.g. 103 (you can have 20 account with number in range of 100-119). - Password: input password (better the same as account ID). - Click [Save] button at bottom of page to keep settings you have made. - Click [Start pairing] button. Tecom AG-300 Plus2 IoT Gateway Operation Manual - To edit user account: check the [Select] column; click the [Edit] button, and the existing settings of the account displays for you to change. - To delete user account: when the user was disconnected check the [Select] column, click the [Delete] button to remove the account. 3. VB200 setup This portable vibration diagnosis instrument supports up to 4 magnetic VB- 200ST(U)/VB-200SC for concurrent measurement, analysis, and diagnosis; see section "RS485 wiring" for its installation. The VB-200 series vibration gauge comes with default value of RS485 ID at 15; one RS485 cable may connect one VB-200 series vibration gauge only; factory default of this portable vibration diagnosis instrument may connect two VB-200 series vibration gauge; please connect the latter to the 1st and 2nd RS485 port of AG- 300 Plus2; the 3rd and 4th RS485 ports are reserved for expansion in the future; to connect 3 or more VB-200 series vibration gauge you need to add RS485 device in the management page first. Connect only one VB-200 series vibration gauge in a RS485 port, otherwise the system may fail to identify individual gauge as each of them bears the same RS485 ID value of 15; please make sure only one VB-200 series vibration gauge is connected to one RS485 port to prevent setup confusion. Please follow steps below to add the 3rd VB-200 series vibration gauge: In main menu on the left, click [Settings] [RS485]. The VB200 page displays and click [Add] option in it. Tecom AG-300 Plus2 IoT Gateway Operation Manual - Name: "VB-200" or any name you like. - Line: select line 3 ~ 4 (line 1~2 added by factory default). - RS485 ID: please fill in a value compliant with your RS485 configuration (this system support RS485 ID in range of 0-15). - Click [Save] button at bottom of page. Tecom AG-300 Plus2 IoT Gateway Operation Manual - To edit the settings of VB-200: check the [Select] column, click the [Edit] button, and the existing settings display for you to change. - To delete settings of VB-200: check the [Select] column, click the [Delete] button to remove the VB-200 vibration gauge. - To add VB-200 vibration gauge: click the [Add] button to add new VB-200 setup. Tecom AG-300 Plus2 IoT Gateway Operation Manual 4. Wireless setup Designed for e-gateway AG-300 Plus2 hardware, the "wireless setup" page contains options of WiFi mode, "Basic", "Advanced", "Security", and "Station list". You may set WiFi mode into "Wireless AP mode" and "Wireless client mode". The wireless AP mode is an AP with gateway serving as WiFi access point. The wireless client mode set the gateway as a client to connect to other WiFi AP. 4.1 The wireless AP mode configuration (WiFi mode setup) Tecom AG-300 Plus2 IoT Gateway Operation Manual 4.1.1 Basic wireless settings This option enables user to set up basic wireless communication parameters including network name and mode with WiFi function default to Enable. WiFi [Enable] page: see figure below: WiFi [Disable] page: see figure below: Tecom AG-300 Plus2 IoT Gateway Operation Manual 4.1.2 Advanced wireless settings This option is aimed at setting up country/region and support channel with page as shown in figure below: 4.1.3 Wireless security/encryption settings This option is aimed at setting up wireless security and encryption to prevent equipment access and monitoring without certification; available security modes are WPASKWPA2PSK and Disable with factory default set to the latter. See figure below for page of this option: Tecom AG-300 Plus2 IoT Gateway Operation Manual Set up WPA algorithm, pass phrase, and key renewal interval; once set up and saved successfully users are required to input pass phrase set up here to connect to WiFi. Tecom AG-300 Plus2 IoT Gateway Operation Manual The client end is required to log in WiFi router of e-gateway AG-300 Plus2 with his/her smartphone: Tecom AG-300 Plus2 IoT Gateway Operation Manual 4.1.4 Station list Users of this solution may monitor clients connected to AP. 4.2 WiFi mode setting Select STA mode and click [Apply] in the WiFi mode setting. Tecom AG-300 Plus2 IoT Gateway Operation Manual 4.2.1 Station profile Having a gateway as an ordinary client, this page displays information of APs saved in the gateway; you may add, delete, and edit information of desired AP; select an AP and click "Open", the gateway will then auto connect to the AP; even after gateway restart connection to pre-set AP will be established automatically. Click the "Add" or "Edit" button and the AP data edit page displays. Tecom AG-300 Plus2 IoT Gateway Operation Manual 4.2.2 Edit station profile In most cases, users may change parameters of "Name", "SSID", "BSSID" and "Security policy" and leave default value of the others intact in the station profile edit page. "Name": name of the profile "SSID": name of AP "BSSID": MAC address of AP "Security policy": encryption mechanism of given AP Tecom AG-300 Plus2 IoT Gateway Operation Manual 4.2.3 Station link status Link information after gateway connected to AP is shown here. 4.2.4 Scan near AP Tecom AG-300 Plus2 IoT Gateway Operation Manual Scan gateway neighboring APs for information Click "Connect" to connect the AP; data of the latter are not saved (data lost after gateway restarted). Click "Rescan to scan" neighboring APs once again. Scanning may fail to identify all APs when there are many available nearby; rescan couple of times may be needed in case like this. Click the "Add profile" button to save AP data in station profile file. 5. Hardware setup AG-300 Plus2 pins definition diagram Vibration gauge RS485 USB Vibration gauge RS485 USB WAN port Reserved LAN port Power Tecom AG-300 Plus2 IoT Gateway Operation Manual APP software operation By following steps set in homepage of [Pro-3200 installation and measurement quick guide 1-2-3] users of this vibration diagnosis instrument may auto connect to it for instant operation data query and vibration diagnosis analysis and report without account setup and login. Follow steps below to set up your vibration diagnosis instrument for user account and server IP address. 1. Open the [Vibration Diagnosis] APP on your smartphone 2. This vibration diagnosis instrument provides PnP quick online diagnosis; log in account 100~119 without other parameter settings as shown in figure below: 100 100 192.168.168.10 100 3. Input Account: 100, Password: 100, Address: 192.168.168.10, Name: 100 or custom values defined earlier; initial values of account, password, and name are set to be the same; the system comes with 20 accounts (100~119) for equipment pairing use. - Account: 100 (there are 20 accounts available with ID in range of 100-119). - Password: your personal password (better the same as account ID). - Server IP: the IP address or server ID set by AG-300 Plus2. - Server name: name of AG-300 Plus2 server. Tecom AG-300 Plus2 IoT Gateway Operation Manual 4. Check [Remember account], press [Log in], and the vibration diagnosis instrument page displays. 5. Please follow APP wizard to execute the following vibration diagnosis operation: (1) Vibration measures: select this option to monitor vibration readings of target E&M equipment; note that this is a pure monitoring function and without data saving. (2) Diagnosis: Select this option for vibration measurement, analysis, and diagnosis with steps: [Input equipment data] [Vibration measurement] [Analysis diagnosis]; please follow APP wizard to get complete vibration analysis and diagnosis report. (3) Report management: Access and manage reports provided by the system; distribute them to relevant personnel by email or communication software anywhere anytime. 6. If you have checked the [Remember Account] option, you may click the "V" icon on the right of account direct and fast login as shown in figure below: Quick login step 1-2-3 Click the Click Press 7. Please check steps below if you failed to login: (1) Is networking function of your smartphone enabled? (2) Is network signal of smartphone in good conditions? (3) Is AG-300 Plus2 powered on? (4) AG-300 Plus2 equipment pairing set up? (5) Is AG-300 Plus2 networking function in normal conditions? (6) Is smartphone and AG-300 Plus2 WiFi [connected]? Tecom AG-300 Plus2 IoT Gateway Operation Manual Note: you may get Host ID on the AG-300 setup page once it is connected to external network. In the main menu on the left, click [Device Info] [Status Overview] option, to get Host ID in the System Info window. TECOM Corp., Ltd No.23, R & D Rd. II, Hsinchu Science-based Industrial Park, Hsinchu, Taiwan, 300 TEL: +886-3-5775141 FAX: +886-3-5776855 http://www.tecom.com.tw Distributor Ver: 02 2017.11 This manual may be modified when necessary because of improvement of the product, modification, or change in specifications. This manual is subject to change without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1-701 Create Date : 2017:11:21 12:04:30Z Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2018:01:04 14:47:18+08:00 Metadata Date : 2018:01:04 14:47:18+08:00 Format : application/pdf Creator : tw4972 Title : (Microsoft Word - \252F\260T\245\376\264\274\274zAG-300 Plus2\250\317\245\316\244\342\245U_EN_ R01_20171121.doc) Producer : GPL Ghostscript 8.15 Document ID : uuid:8fb83567-9743-4dca-8bd9-c3466205ea34 Instance ID : uuid:b7401683-f136-449c-9992-901f63bb758d Has XFA : No Page Count : 30 Author : tw4972EXIF Metadata provided by EXIF.tools