TI PROPRIETARY  T E X A S   I N S T R U M E N T S  Originator : INFORMATION -           C. BohrenINTERNAL DATA  R F I D  SYSTEMS     S P E C I F I C A T I O N     Revision: 00  User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 1 of 15  XX-XX-XX-XXX            Subco/Mfg Spec.  User Guide Test Control Software  S4110 MFR Evaluation Kit       PRINTED COPIES OF THIS SPECIFICATION ARE NOT CONTROLLED DOCUMENTS.  VERIFY THEIR CORRECT REVISION BEFORE USE.
TI PROPRIETARY  T E X A S   I N S T R U M E N T S   INFORMATION -    Revision: INTERNAL DATA  R F I D  SYSTEMS  00   S P E C I F I C A T I O N     User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 2 of 15  XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TABLE OF CONTENTS  PAGE  1. Purpose..............................................................................................................3 2. Hardware Set up...............................................................................................3 2.1  S4110 MFR Evaluation Kit Hardware supplied...........................................3 2.2  Hardware Set Up.........................................................................................4 3. Test Software ....................................................................................................5 3.1  Initial Start Screen ......................................................................................5 3.2  Connection to RS232 Communications (Com) Port.....................................5 3.2.1 Communications Port Choices.............................................................5 3.3  Turn On HF Transmitter .............................................................................6 3.4  Turn On LF Transmitter..............................................................................8 3.5  Turn Off HF Transmitter...........................................................................10 3.6  Turn Off LF Transmitter ...........................................................................11 3.7  Close Com Port.........................................................................................12 3.8 Close Application .....................................................................................13 4. Installation Guide S4110R MFR Evaluation Kits as shipped from factory .13 4.1  Box Unit S4110 MFR Evaluation Kit as shipped from factory ..................14 4.1.1  Placement of FCC Label on Box Unit ...............................................14 4.2  SDK Unit S4110 MFR Evaluation Kit as shipped from factory.................14 4.2.1  Placement of FCC Label on Box Unit ...............................................14 5. Revision History..............................................................................................15  LIST OF FIGURES  Figure 1: Back Panel MFR Evaluation Kit Black Box Reader.............................. 3 Figure 2: Software Development Kit (SDK)........................................................... 3 Figure 3: Globtek Power Supply Model Number: GT-21089-1509-T3................. 4 Figure 4: Hardware Set Up MFR Evaluation Kit.................................................. 4 Figure 5: Initial Start Screen .................................................................................. 5 Figure 6: Com Port Choices supported.................................................................. 6 Figure 7: Successful “Com” Port Connection........................................................ 7 Figure 8: Turn On HF Transmitter........................................................................ 7 Figure 9: Successful "Turn On " of HF Transmitter ............................................ 8 Figure 10: Turn On LF Transmitter ...................................................................... 9 Figure 11: Successful “Turn On” of LF Transmitter ............................................ 9 Figure 12: Turn Off HF Transmitter ....................................................................10 Figure 13:  Turn Off LF Transmitter....................................................................11 Figure 14: Com Port Closure.................................................................................12 Figure 15: Successful Com Port Closure...............................................................13 Figure 16: FCC Label for S4110R MFR Evaluation Kit......................................13 Figure 17: Placement of FCC Label on S4110R Evaluation Kit Box Unit...........14 Figure 18: Placement of FCC Label on S4110R Evaluation Kit SDK Unit .........14
TI PROPRIETARY  T E X A S   I N S T R U M E N T S   INFORMATION -    Revision: INTERNAL DATA  R F I D  SYSTEMS  00   S P E C I F I C A T I O N     User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 3 of 15  XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. 1. Purpose The purpose of this document is to demonstrate the Test Control software for the S4110 MFR Evaluation Kit.. 2. Hardware Set up 2.1  S4110 MFR Evaluation Kit Hardware supplied 1)  S4110 MFR Evaluation Kit Black Box Reader 2)  S4110 MFR Evaluation Kit Software Development Kit (SDK) Reader 3)  Power Supply, 9.0 Vdc 1.0 A, Globtek Part Number: TR9CD1700LCP-Y Globtek Model Number: GT-21089-1509-T3       Figure 1: Back Panel MFR Evaluation Kit Black Box Reader  Figure 2: Software Development Kit (SDK) DC Power connector +9 Vdc is center pin  RS485 Connector RS232 Connector
TI PROPRIETARY  T E X A S   I N S T R U M E N T S   INFORMATION -    Revision: INTERNAL DATA  R F I D  SYSTEMS  00   S P E C I F I C A T I O N     User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 4 of 15  XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use.  Figure 3: Globtek Power Supply Model Number: GT-21089-1509-T3 Globtek Part Number: TR9CD1700CP-Y 2.2 Hardware Set Up RS232RS485+9 VoltsDCPower Communicationsboard  ConnectorJ232  RS232J485RS485J12  PowerConnector, DB9MPC withMFR EvalKitTestSoftwarePC Com 1Serial RS232PortNo ConnectionPower Supply9V DC 1.0 AmpGlobtek  PN: TR9CD1700CP-YModel Number: GT-21089-1509-T3ConnectorCircularDINS4100 MFR LiteMFR Evaluation KitHF/LF AntennaBoardTAGD = Distance form Tag to Reader "D" Figure 4: Hardware Set Up MFR Evaluation Kit
TI PROPRIETARY  T E X A S   I N S T R U M E N T S   INFORMATION -    Revision: INTERNAL DATA  R F I D  SYSTEMS  00   S P E C I F I C A T I O N     User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 5 of 15  XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. 3. Test Software 3.1  Initial Start Screen 1)  After double clicking the MFR Demo software icon the software screen below will appear. 2)  Double click desired application folder tab to select application.   Figure 5: Initial Start Screen 3.2  Connection to RS232 Communications (Com) Port 1)  Click on ‘Connect’ button to open the COM port. You’ll see the red indicator box with ‘COM Closed’ text change color to GREEN and read ‘COM Opened’ for successful connection. 2)  If red indicator box stays red and reads ‘Com Closed’, the COM port did not open successfully. 3.2.1 Communications Port Choices 1)  If the default Com Port of Com1 is not the desired Com Port, use Com Port selection arrow to select desired Com Port; from the following choices 1) Com1, 2) Com2, 3) Com3, 4) Com4.  Press to Open “Com” Port Selects desired ‘Com’ port When Status Box is Green ‘Com’ port is open
TI PROPRIETARY  T E X A S   I N S T R U M E N T S   INFORMATION -    Revision: INTERNAL DATA  R F I D  SYSTEMS  00   S P E C I F I C A T I O N     User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 6 of 15  XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. 2)  Click on ‘Connect’ button to open the COM port. You’ll see the red indicator box with ‘COM Closed’ text change color to GREEN and read ‘COM Opened’ for successful connection. 3)  If red indicator box stays red and reads ‘Com Closed’, the COM port did not open successfully.         Figure 6: Com Port Choices supported 3.3  Turn On HF Transmitter To Turn on the HF Transmitter: 1)  Select 14443A Library folder Tab 2)  Under 14443A Library folder Tab select Transmitter On 3)  Click on ‘Execute’ button to issue a HF- Transmitter ON Command. 4)  If successful, you would see the Green indicator with ‘TRANSMITTER ON – 14443A’ text.  Use Com Port SelectArrow to select desired Com Port
TI PROPRIETARY  T E X A S   I N S T R U M E N T S   INFORMATION -    Revision: INTERNAL DATA  R F I D  SYSTEMS  00   S P E C I F I C A T I O N     User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 7 of 15  XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use.  Figure 7: Successful “Com” Port Connection   Figure 8: Turn On HF Transmitter  When Status Box is Green ‘Com’ port is open Select Folder for  14443-A Library to start HF transmitter turn on procedure HF Transmitter On Folder TabPress to turn on HF  (13.56 MHz) Transmitter
TI PROPRIETARY  T E X A S   I N S T R U M E N T S   INFORMATION -    Revision: INTERNAL DATA  R F I D  SYSTEMS  00   S P E C I F I C A T I O N     User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 8 of 15  XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use.    Figure 9: Successful "Turn On " of HF Transmitter 3.4 Turn On LF Transmitter To Turn on the LF Transmitter: 1)  Select LF-DST Library folder Tab 2)  Under LF-DST Library folder Tab select Transmitter On 3)  Click on ‘Execute’ button to issue a LF- Transmitter ON Command. 4)  If successful, you would see the Green indicator with ‘TRANSMITTER ON – LF-DST’ text.              HF (13.56 MHz) Transmitter On Select Folder for  LF-DST Library to start LF transmitter turn on procedure
TI PROPRIETARY  T E X A S   I N S T R U M E N T S   INFORMATION -    Revision: INTERNAL DATA  R F I D  SYSTEMS  00   S P E C I F I C A T I O N     User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 9 of 15  XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use.    Figure 10: Turn On LF Transmitter  Figure 11: Successful “Turn On” of LF Transmitter  LF Transmitter    On Folder Tab Press to turn on LF  (134 kHz) TransmitterLF (134 kHz) Transmitter On Select Folder for  LF-DST Library to start LF transmitter turn on procedure
TI PROPRIETARY  T E X A S   I N S T R U M E N T S   INFORMATION -    Revision: INTERNAL DATA  R F I D  SYSTEMS  00   S P E C I F I C A T I O N     User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 10 of 15  XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. 3.5  Turn Off HF Transmitter To Turn Off the HF Transmitter: 1)  Select 14443A Library folder Tab 2)  Under 14443A Library folder Tab select Transmitter Off 3)  Click on ‘Execute’ button to issue a HF- Transmitter Off Command. 4)  If successful, you would see the Green indicator with ‘TRANSMITTER OFF – 14443A’ text.         Figure 12: Turn Off HF Transmitter      HF Transmitter  Off Folder Tab Press to turn off HF    (13.56 MHz) TransmitterSelect Folder for 14443-A Library to start HF transmitter turn  off procedure
TI PROPRIETARY  T E X A S   I N S T R U M E N T S   INFORMATION -    Revision: INTERNAL DATA  R F I D  SYSTEMS  00   S P E C I F I C A T I O N     User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 11 of 15  XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. 3.6  Turn Off LF Transmitter To Turn off the LF Transmitter: 1)  Select LF-DST Library folder Tab 2)  Under LF-DST Library folder Tab select Transmitter OFF 3)  Click on ‘Execute’ button to issue a LF- Transmitter OFF Command. 4)  If successful, you would see the Green indicator with ‘TRANSMITTER OFF – LF-DST’ text.        Figure 13:  Turn Off LF Transmitter        Select Folder for  LF-DST Library to start LF transmitter turn off procedure LF Transmitter  Off Folder Tab
TI PROPRIETARY  T E X A S   I N S T R U M E N T S   INFORMATION -    Revision: INTERNAL DATA  R F I D  SYSTEMS  00   S P E C I F I C A T I O N     User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 12 of 15  XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. 3.7  Close Com Port 1)  Close the COM port by clicking on ‘Disconnect’ button.  2)  You will see the Green Status Indicator with ‘COM Open’ text, change color to RED with a text change to ‘Com Closed to indicate successful closure of the COM port.        Figure 14: Com Port Closure    Press “Disconnect” Button to Close ‘Com Port’
TI PROPRIETARY  T E X A S   I N S T R U M E N T S   INFORMATION -    Revision: INTERNAL DATA  R F I D  SYSTEMS  00   S P E C I F I C A T I O N     User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 13 of 15  XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use.  Figure 15: Successful Com Port Closure 3.8 Close Application 1)  Click EXIT button to close the application. 4.  Installation Guide S4110R MFR Evaluation Kits as shipped from factory The Box unit and SDK unit configurations of the S4110 MFR Evaluation Kit as shipped from the factory are compliant with FCC Part 15 Rules.           Figure 16: FCC Label for S4110R MFR Evaluation Kit      FCC ID:  A92S4110R         Made in USA  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)  This device may not cause harmful interference, and (2)  This device must accept any interference received, including interference that may cause undesired operation.
TI PROPRIETARY  T E X A S   I N S T R U M E N T S   INFORMATION -    Revision: INTERNAL DATA  R F I D  SYSTEMS  00   S P E C I F I C A T I O N     User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 14 of 15  XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. 4.1  Box Unit S4110 MFR Evaluation Kit as shipped from factory 4.1.1  Placement of FCC Label on Box Unit  Figure 17: Placement of FCC Label on S4110R Evaluation Kit Box Unit 4.2  SDK Unit S4110 MFR Evaluation Kit as shipped from factory 4.2.1  Placement of FCC Label on Box Unit Figure 18: Placement of FCC Label on S4110R Evaluation Kit SDK Unit
TI PROPRIETARY  T E X A S   I N S T R U M E N T S   INFORMATION -    Revision: INTERNAL DATA  R F I D  SYSTEMS  00   S P E C I F I C A T I O N     User Guide Test Control Software  S4110 MFR Evaluation Kit  Page 15 of 15  XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. 5. Revision History  Rev. SCN Description of Change Date submitted By 0  New Issue  04/20/2004 C.Bohren