Texas Instruments S4110R S4110 MFR Based Reader Evaluation Kit User Manual
Texas Instruments Inc S4110 MFR Based Reader Evaluation Kit Users Manual
Users Manual
TI PROPRIETARY Originator C. Bohren TEXAS INSTRUMENTS INFORMATION INTERNAL DATA R F I D SYSTEMS SPECIFICATION Subco/Mfg Spec. User Guide Test Control Software S4110 MFR Evaluation Kit PRINTED COPIES OF THIS SPECIFICATION ARE NOT CONTROLLED DOCUMENTS. VERIFY THEIR CORRECT REVISION BEFORE USE. Revision: 00 User Guide Test Control Software S4110 MFR Evaluation Kit Page 1 of 15 XX-XX-XX-XXX TI PROPRIETARY INFORMATION INTERNAL DATA TEXAS INSTRUMENTS R F I D SYSTEMS SPECIFICATION TABLE OF CONTENTS Revision: 00 PAGE 1. Purpose..............................................................................................................3 2. Hardware Set up...............................................................................................3 2.1 S4110 MFR Evaluation Kit Hardware supplied...........................................3 2.2 Hardware Set Up.........................................................................................4 3. Test Software ....................................................................................................5 3.1 Initial Start Screen ......................................................................................5 3.2 Connection to RS232 Communications (Com) Port.....................................5 3.2.1 Communications Port Choices.............................................................5 3.3 Turn On HF Transmitter .............................................................................6 3.4 Turn On LF Transmitter..............................................................................8 3.5 Turn Off HF Transmitter...........................................................................10 3.6 Turn Off LF Transmitter ...........................................................................11 3.7 Close Com Port.........................................................................................12 3.8 Close Application .....................................................................................13 4. Installation Guide S4110R MFR Evaluation Kits as shipped from factory .13 4.1 Box Unit S4110 MFR Evaluation Kit as shipped from factory ..................14 4.1.1 Placement of FCC Label on Box Unit ...............................................14 4.2 SDK Unit S4110 MFR Evaluation Kit as shipped from factory .................14 4.2.1 Placement of FCC Label on Box Unit ...............................................14 5. Revision History..............................................................................................15 LIST OF FIGURES Figure 1: Back Panel MFR Evaluation Kit Black Box Reader.............................. 3 Figure 2: Software Development Kit (SDK)........................................................... 3 Figure 3: Globtek Power Supply Model Number: GT-21089-1509-T3 ................. 4 Figure 4: Hardware Set Up MFR Evaluation Kit.................................................. 4 Figure 5: Initial Start Screen .................................................................................. 5 Figure 6: Com Port Choices supported .................................................................. 6 Figure 7: Successful “Com” Port Connection ........................................................ 7 Figure 8: Turn On HF Transmitter........................................................................ 7 Figure 9: Successful "Turn On " of HF Transmitter ............................................ 8 Figure 10: Turn On LF Transmitter ...................................................................... 9 Figure 11: Successful “Turn On” of LF Transmitter ............................................ 9 Figure 12: Turn Off HF Transmitter ....................................................................10 Figure 13: Turn Off LF Transmitter....................................................................11 Figure 14: Com Port Closure.................................................................................12 Figure 15: Successful Com Port Closure ...............................................................13 Figure 16: FCC Label for S4110R MFR Evaluation Kit ......................................13 Figure 17: Placement of FCC Label on S4110R Evaluation Kit Box Unit...........14 Figure 18: Placement of FCC Label on S4110R Evaluation Kit SDK Unit .........14 User Guide Test Control Software S4110 MFR Evaluation Kit Page 2 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION INTERNAL DATA 1. TEXAS INSTRUMENTS R F I D SYSTEMS SPECIFICATION Revision: 00 Purpose The purpose of this document is to demonstrate the Test Control software for the S4110 MFR Evaluation Kit.. 2. 2.1 Hardware Set up S4110 MFR Evaluation Kit Hardware supplied 1) S4110 MFR Evaluation Kit Black Box Reader 2) S4110 MFR Evaluation Kit Software Development Kit (SDK) Reader 3) Power Supply, 9.0 Vdc 1.0 A, Globtek Part Number: TR9CD1700LCP-Y Globtek Model Number: GT-21089-1509-T3 DC Power connector +9 Vdc is center pin RS485 Connector RS232 Connector Figure 1: Back Panel MFR Evaluation Kit Black Box Reader Figure 2: Software Development Kit (SDK) User Guide Test Control Software S4110 MFR Evaluation Kit Page 3 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION INTERNAL DATA TEXAS INSTRUMENTS Revision: 00 R F I D SYSTEMS SPECIFICATION Figure 3: Globtek Power Supply Model Number: GT-21089-1509-T3 Globtek Part Number: TR9CD1700CP-Y 2.2 Hardware Set Up PC with MFR Eval Kit Test Software PC Com 1 Serial RS232 Port Communications board Connector J232 RS232 RS232 Connector, DB9M J485 RS485 No Connection Power Supply 9V DC 1.0 Amp Globtek PN: TR9CD1700CP-Y Model Number: GT-21089-1509T3 Connector Circular DIN J12 Power S4100 MFR Lite RS485 HF/LF Antenna Board +9 Volts DC Power MFR Evaluation Kit D = Distance form Tag to Reader "D TAG Figure 4: Hardware Set Up MFR Evaluation Kit User Guide Test Control Software S4110 MFR Evaluation Kit Page 4 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION INTERNAL DATA 3. 3.1 TEXAS INSTRUMENTS R F I D SYSTEMS SPECIFICATION Revision: 00 Test Software Initial Start Screen 1) After double clicking the MFR Demo software icon the software screen below will appear. 2) Double click desired application folder tab to select application. Selects desired ‘Com’ port Press to Open “Com” Port When Status Box is Green ‘Com’ port is open Figure 5: Initial Start Screen 3.2 Connection to RS232 Communications (Com) Port 1) Click on ‘Connect’ button to open the COM port. You’ll see the red indicator box with ‘COM Closed’ text change color to GREEN and read ‘COM Opened’ for successful connection. 2) If red indicator box stays red and reads ‘Com Closed’, the COM port did not open successfully. 3.2.1 Communications Port Choices 1) If the default Com Port of Com1 is not the desired Com Port, use Com Port selection arrow to select desired Com Port; from the following choices 1) Com1, 2) Com2, 3) Com3, 4) Com4. User Guide Test Control Software S4110 MFR Evaluation Kit Page 5 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION INTERNAL DATA TEXAS INSTRUMENTS R F I D SYSTEMS SPECIFICATION Revision: 00 2) Click on ‘Connect’ button to open the COM port. You’ll see the red indicator box with ‘COM Closed’ text change color to GREEN and read ‘COM Opened’ for successful connection. 3) If red indicator box stays red and reads ‘Com Closed’, the COM port did not open successfully. Use Com Port Select Arrow to select desired Com Port Figure 6: Com Port Choices supported 3.3 Turn On HF Transmitter To Turn on the HF Transmitter: 1) Select 14443A Library folder Tab 2) Under 14443A Library folder Tab select Transmitter On 3) Click on ‘Execute’ button to issue a HF- Transmitter ON Command. 4) If successful, you would see the Green indicator with ‘TRANSMITTER ON – 14443A’ text. User Guide Test Control Software S4110 MFR Evaluation Kit Page 6 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION INTERNAL DATA TEXAS INSTRUMENTS R F I D SYSTEMS SPECIFICATION Revision: 00 Select Folder for 14443-A Library to start HF transmitter turn on procedure When Status Box is Green ‘Com’ port is open Figure 7: Successful “Com” Port Connection HF Transmitter On Folder Tab Press to turn on HF (13.56 MHz) Transmitter Figure 8: Turn On HF Transmitter User Guide Test Control Software S4110 MFR Evaluation Kit Page 7 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION INTERNAL DATA TEXAS INSTRUMENTS R F I D SYSTEMS SPECIFICATION Revision: 00 Select Folder for LF-DST Library to start LF transmitter turn on procedure HF (13.56 MHz) Transmitter On Figure 9: Successful "Turn On " of HF Transmitter 3.4 Turn On LF Transmitter To Turn on the LF Transmitter: 1) Select LF-DST Library folder Tab 2) Under LF-DST Library folder Tab select Transmitter On 3) Click on ‘Execute’ button to issue a LF- Transmitter ON Command. 4) If successful, you would see the Green indicator with ‘TRANSMITTER ON – LF-DST’ text. User Guide Test Control Software S4110 MFR Evaluation Kit Page 8 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION INTERNAL DATA TEXAS INSTRUMENTS R F I D SYSTEMS SPECIFICATION Revision: 00 Select Folder for LF-DST Library to start LF transmitter turn on procedure LF Transmitter On Folder Tab Press to turn on LF (134 kHz) Transmitter Figure 10: Turn On LF Transmitter LF (134 kHz) Transmitter On Figure 11: Successful “Turn On” of LF Transmitter User Guide Test Control Software S4110 MFR Evaluation Kit Page 9 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION INTERNAL DATA 3.5 TEXAS INSTRUMENTS R F I D SYSTEMS SPECIFICATION Revision: 00 Turn Off HF Transmitter To Turn Off the HF Transmitter: 1) Select 14443A Library folder Tab 2) Under 14443A Library folder Tab select Transmitter Off 3) Click on ‘Execute’ button to issue a HF- Transmitter Off Command. 4) If successful, you would see the Green indicator with ‘TRANSMITTER OFF – 14443A’ text. Select Folder for 14443-A Library to start HF transmitter turn off procedure HF Transmitter Off Folder Tab Press to turn off HF (13.56 MHz) Transmitter Figure 12: Turn Off HF Transmitter User Guide Test Control Software S4110 MFR Evaluation Kit Page 10 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION INTERNAL DATA 3.6 TEXAS INSTRUMENTS R F I D SYSTEMS SPECIFICATION Revision: 00 Turn Off LF Transmitter To Turn off the LF Transmitter: 1) Select LF-DST Library folder Tab 2) Under LF-DST Library folder Tab select Transmitter OFF 3) Click on ‘Execute’ button to issue a LF- Transmitter OFF Command. 4) If successful, you would see the Green indicator with ‘TRANSMITTER OFF – LF-DST’ text. Select Folder for LF-DST Library to LF Transmitter start LF transmitter Off Folder Tab turn off procedure Figure 13: Turn Off LF Transmitter User Guide Test Control Software S4110 MFR Evaluation Kit Page 11 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION INTERNAL DATA 3.7 TEXAS INSTRUMENTS R F I D SYSTEMS SPECIFICATION Revision: 00 Close Com Port 1) Close the COM port by clicking on ‘Disconnect’ button. 2) You will see the Green Status Indicator with ‘COM Open’ text, change color to RED with a text change to ‘Com Closed to indicate successful closure of the COM port. Press “Disconnect” Button to Close ‘Com Port’ Figure 14: Com Port Closure User Guide Test Control Software S4110 MFR Evaluation Kit Page 12 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION INTERNAL DATA TEXAS INSTRUMENTS R F I D SYSTEMS SPECIFICATION Revision: 00 Figure 15: Successful Com Port Closure 3.8 Close Application 1) Click EXIT button to close the application. 4. Installation Guide S4110R MFR Evaluation Kits as shipped from factory The Box unit and SDK unit configurations of the S4110 MFR Evaluation Kit as shipped from the factory are compliant with FCC Part 15 Rules. FCC ID: A92S4110R Made in USA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Figure 16: FCC Label for S4110R MFR Evaluation Kit User Guide Test Control Software S4110 MFR Evaluation Kit Page 13 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION INTERNAL DATA 4.1 TEXAS INSTRUMENTS Revision: 00 R F I D SYSTEMS SPECIFICATION Box Unit S4110 MFR Evaluation Kit as shipped from factory 4.1.1 Placement of FCC Label on Box Unit Figure 17: Placement of FCC Label on S4110R Evaluation Kit Box Unit 4.2 SDK Unit S4110 MFR Evaluation Kit as shipped from factory 4.2.1 Placement of FCC Label on Box Unit Figure 18: Placement of FCC Label on S4110R Evaluation Kit SDK Unit User Guide Test Control Software S4110 MFR Evaluation Kit Page 14 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION INTERNAL DATA TEXAS INSTRUMENTS R F I D SYSTEMS SPECIFICATION Revision: 00 NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. 5. Revision History Rev. SCN Description of Change New Issue User Guide Test Control Software S4110 MFR Evaluation Kit Date submitted 04/20/2004 Page 15 of 15 By C.Bohren XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Create Date : 2004:05:17 08:56:47Z Modify Date : 2004:05:17 10:05:33-05:00 Page Count : 15 Creation Date : 2004:05:17 08:56:47Z Producer : Acrobat Distiller 4.05 for Windows Mod Date : 2004:05:17 10:05:33-05:00 Metadata Date : 2004:05:17 10:05:33-05:00EXIF Metadata provided by EXIF.tools