Tokyo Hy Power Labs HL-2500FX HF 50 MHz LINEAR POWER AMPLIFIER User Manual
Tokyo Hy-Power Labs, Inc. HF 50 MHz LINEAR POWER AMPLIFIER
User Manual
INSTRUCTION MANUAL HF ・50MHz LINEAR POWER AMPLIFIER ON AIR FAN ID Pf/kW Pr/VD/ID/ALC PROT HF SOLID STATE LINEAR AMPLIFIER HL-2500FX POWER OPER. OUTPUT HI VD METER ID ALC ANT BAND AUTO Pr OFF STBY LO -0- MAN’L 10 MAN’L 14 18/21 3.5 24/28 1.8 50 1.Introduction Thank you for purchasing the HL-2500FX. This compact and lightweight desktop HF linear power amplifier has a maximum input power of 2.9 kW. Our solid-state broadband power amp technology makes it the smallest and lightest in the industry. Typical output power is 1.5 kW PEP/SSB on HF (1kW on 50MHz) with the drive power of 85-90 W. The built-in band decoder will let you forget about the band setting when the amplifier is connected to your modern radio through such band data cables as ICOM CI-V, DC voltage (Yaesu and Elecraft K3), and RS-232C (Kenwood). These data cables are optional parts. The one that matches your radio should be purchased separately. 2. Cautions 2-1 Unpack the amplifier, check the fan guard at the rear panel fan to see if there is any damage caused by the physical shock during the transportation. Fan blades must be free to rotate when powered. The amplifier is cooled by forced airflow. Several inches of clearance on the top and the rear wall are necessary to allow for smooth air intake into the fan. Do not block the air vents on the top cover. 2-2 Keep the amplifier out of direct sunlight, in a cool dry environment. 2-3 Internal high voltages, (AC, DC and RF), are present at all times, ON AIR or OFF. Internal access should be limited to avoid injury. 2-4 Turn off the AC main power immediately upon any unusual sounds, sights or odors. Check the multimeter readings of Vd and Id, the fuses and all cable connections around the amplifier. Please notify the dealer or the factory of any problems. 2-5 For your safety, do not operate the amplifier without adequate grounding. A proper ground connection will result in peak performance and stability, in addition to reduced RF strays or noises. 2-6 To eliminate the RF interference to such home appliances as TV, FM radio, telephone sets, etc., -1- it is recommended that clamp-on ferrite cores be inserted at both ends of the remote control cable, ALC cable, coaxial jumper cable, and antenna cables, as needed. Also, a common mode AC line filter (near the AC outlet), and in-line low pass filters on the antenna coaxial cable, (as necessary), are recommended. 2-7 The amplifier has fast acting sophisticated protection circuits controlled by the latest microprocessor technology. Please note, however, any such actions that cause the same fault to occur repeatedly, will lead to failure of the valuable final power FET transistors. Also note that the full power CW (or carrier) drive under the erroneous MANUAL BAND SET leads to the failure of the final power FET’s (See page 14, Section 10. Trial). In this sense, it is highly recommended that the amplifier is connected to the radio with Band Data Cable. 2-8 Before checking inside the amplifier, be sure to wait a few minutes for the high DC voltage to discharge (monitor Vd meter reading). The internal potentiometers for RF power detector, protection circuits, FET bias voltage circuit, etc., are precisely adjusted at the factory, and should not be altered. Doing so, would require readjustment with precision measuring instruments. 2-9 DC power supply selection is designed with wide AC line voltage technology and works with any voltage of 200V to 250V as well as 100V to 125V. 200V to 250V line, however, is recommended for the best stability and performance. Note that maximum output power is 1kW only, when 100V to 125V is connected. Prepare appropriate AC power cord plug that fits the outlet at your location. 2-10 Before powering on the amplifier, be sure to connect a dummy load (50 ohms, 1.5 kW min.) or a well-adjusted antenna to the output terminal. Operating without any load will cause extreme stress to the RF power FET’s, although protection circuits should work under critical conditions. 2-11 Required drive power is slightly less than 100 W to obtain the full 1.5 kW output. Do not attempt to operate with excessive drive from a high power transceiver. Transmitting high drive RF (over 100 W) into the amplifier will void the warranty. -2- 2-12 Keep the aluminum heat sink and air openings free from dust and blockages. Periodic cleaning will prevent degraded cooling efficiency. 2-13 For long continuous operation in RTTY/FM modes, it is recommended you reduce the RF drive levels by 20% to 30% lower output than CW/SSB modes. 2-14 To prevent damage to the precision electronic components, avoid extreme physical shock to the amplifier. If factory service is required, the amplifier MUST be shipped using the original box and packaging materials. 3. Features 3-1 Our solid-state broadband design engineers worked to make the HL-2500KFX, the lightest and most compact 1.5 kW amplifier in the industry. This world-class compact 1.5 kW amplifier is the easiest to handle and operate. 3-2 The amplifier is equipped with a newly developed band decoder. The amplifier’s decoder changes bands automatically as the data signal is received from the associated HF transceiver’s frequency bands. 3-3The amplifier’s main PA section includes 6 high power MOS FET THP2933’s by Microsemi, resulting in 1.5 kW PEP (SSB max.). The amplifier’s broadband characteristics require no further tuning once the operating band is selected. 3-4 The amplifier allows operation in full break-in CW mode due to the use of the amplifier’s high- speed antenna relays (made by Panasonic). 3-5With the unique duct structure design and the powerful blower fan, the aluminum heat sink block for RF PA module (and other components), are effectively cooled. The fan’s quiet operation allows for even the weakest DX signals to be heard. -3- 3-6 The amp utilizes an advanced 16 bit MPU (microprocessor) to run the various high speed protection circuits such as overdrive, high antenna SWR, DC overvoltage, band mis-set etc. 3-7 This amplifier is compatible with AC 200 V and 250 V as well as AC 100V to 125V. 3-8 For the safety of the operator, an Interlock system is employed. The AC power is shut down if the top cover is removed, and the automated safety interlock is activated. 3-9 An analog multimeter allows the operator to monitor Pr (Reflected power), Vd (Drain voltage of power FET), Id (Drain current) and ALC voltage. 3-10 For future expansion, the amplifier rear panel is equipped with a control cable connection socket TUNER, this is for the upcoming model HC-1500AT, auto antenna tuner by Tokyo Hy-Power Labs. in 2013. -4- 4. Specifications Frequency Mode RF Drive Output Power Matching Transceivers for Auto Band Decoder : Drain Voltage Drain Current Input Impedance Output Impedance Final Transistor Circuit Cooling Method MPU Multi-Meter Input/Output Connectors AC Power AC Consumption Dimension Weight Accessories Optional Items 1.8 ~ 50 MHz all amateur bands including WARC bands SSB, CW, RTTY 85W typ. (100W max.) 1.5 kW PEP/CW (typ.) (1 kW on 50 MHz band) Most ICOM, Yaesu, Kenwood, Elecraft K3, Ten-Tec 50 V (when no RF drive) 60 A max. 50Ω (unbalanced) 50Ω (unbalanced) THP2933 x 6 (MOS FET by Microsemi) Class AB push-pull Forced Air Cooling PIC 18F8722 Output Power Pf 2.5 kW Reflected Power Pr 250W Drain Voltage Vd 60V Drain Current Id 80A UHF SO-239 with low loss Teflon insulator AC 100V ~250V (wide range) 3 kVA max. when TX 370 x 145 x 422 mm (W x H x D) 14.6 x 5.7 x 16.6 inches Approx. 18 kgs. or 41 lbs. AC Power Cord x 1 RCA Plug (Stereo Type Pair Cable) x 1 Spare Fuse 20 A (for AC 200V~250V line) x2 Spare Fuse 20A (In yellow plastic) (DC58V, for FET drain) x3 Spare Fuse 1.6 A (Black) (Miniature Fuse for RF Absolute Over-drive) x1 Spare Fuse 3.2 A (Black) (Miniature Fuse for + 12V Control Circuit Supply and External AUX, Supply)) x2 Instruction Manual x1 Warranty Card x1 Band data cable to radios -5- 5. AC Line Voltage 5-1 The amplifier is designed to work with any AC voltage world wide, (200- 250 V and 100-125V). When connected to 100-125V line, maximum available output power is 1kW on HF and 500W on 6m band. 5-2 The correct AC plug (not included in the package), must be obtained locally due to the AC plug variations worldwide. 5-3 For the best performance and stability, it is strongly recommended that you will connect to AC 230V line (200V~250V). 6.Front Panel Description 10 11 ON AIR FAN ID Pr/VD/ID/ALC Pf/kW PROT HF SOLID STATE LINEAR AMPLIFIER HL-2500FX POWER OPER. OUTPUT HI VD METER ID ALC BAND ANT AUTO Pr OFF STBY LO MAN’L 10 14 18/21 3.5 24/28 1.8 50 MAN’L ①POWER Main power switch. At OPERATE, the amplifier is ready to go into ON AIR (TX) mode and at STBY, it is on STAND-BY mode. ③OUTPUT To select High or Low Output levels. At LO, output is approximately 60% of HI. ④METER To change the multimeter scales. Meter reads Pr, Vd, Id and ALC. ⑤ANT-A/B To Select antenna “A” or “B”. When main power switch is turned off, it is switched to A. -6- ⑥BAND-AUTO/MANUAL To select band switching methods AUTO or MANUAL. When using AUTO, the manufacturer for the transceiver in use should be selected. When the band data cable is not used, MANUAL should be selected. (See page 19, 10 Operation / Setting) ⑦BAND-MANUAL Rotary switch for band change in the manual mode. While the transceiver is on Receive (RX) mode, turn to select the desired frequency band operate. The switches will not work when the transceiver and the amplifier are in Transmit (TX) mode. ⑧METER (PF) Meter to read forward output power, PF. Full scale is 2.5 kW, and it reads average power. ⑨MULTIMETER Pr (Reflected power from antenna), VD (FET drain voltage), ID (FET drain current) and ALC voltage are shown on the scale as selected by ④MANUAL select switch. Full scales are; PR: 250W, VD: 60V, Id: 80A, ALC: -10V. ⑩ONAIR, FAN, ID, PROT (LED) ON AIR : Lights when the amplifier is in transmit (TX) mode. FAN : Lights when cooling fan is running at high speed. When the heat sink temperature reaches 35℃, cooling fan speed will continuously increase to enhance cooling capacity. ID : Excessive ID Indicator (55A). Depending on the band and antenna situation, high drain currency may flow into FET’s. If 55A is exceeded, this LED lights to indicate that high ID is being drawn (This light does not necessarily mean a failure of the amplifier. However, if it lights too often, or too long, it is possible the drive power should be reduced and the antenna should be checked for SWR, to avoid stress to the FET’s) PROT : Lights when protection circuit shuts down the amplifier. Various protection circuits are built in such as Over-drive, Band mis-set, high Ant-SWR, Over-temperature etc. Detailed explanations will follow. ⑪LCD PANEL Displays modes of operation and protection circuit. Detailed explanation will follow. -7- 7 Rear Panel Description ANT B ANT A REMOTE SELECT DC OUT 12V2A TUNER FUSE FUSE CONT INPUT SERIAL ALC ADJ ALC SEND FUSE FUSE AC IN USB 10 11 12 13 14 15 16 17 ①ANT-B RF Output Connector. Connect coax cable to the antenna B. ②ANT-A RF Output Connector. Connect coax cable to the antenna A. ③TUNER DIN Socket. Connect the control cable from External Auto Antenna Tuner, HC-1500AT and or HC-1.5KAT. ④SELECT Switch to select the transceiver (i.e. “CI-V” for ICOM CI-V, “I” for ICOM DC Voltage, “Y” for Yaesu, “K” for Kenwood, “Aux1-3” for three auxiliary positions of N.C./no connection.). ⑤DC OUT 12V 2A, Auxiliary DC power supply terminal. ⑥REMOTE Connector to switch the amp ON and OFF in the remote location. ⑦ALC ADJ. Potentiometer to adjust ALC voltage level. Minus 10 V is available at maximum, when turned fully clockwise. Factory setting is 0 volts, with the pot turned fully counter-clockwise. -8- ⑧ALC RCA Jack for ALC Voltage Output. Negative DC voltage appears at the center pin, which is fed back to the ALC terminal of the transceiver. ALC is used to keep the amplifier output power at certain limits. Also it is useful when the transceiver output power is higher than 100W (Seen page 18, Section 9-C. 7 ALC Adjustment). Also consult with your HF transceiver’s user manual. ⑨SEND RCA Jack. Connect the control cable from the ACC terminal (or SEND, TX GND etc.) of the transceiver. Electrical conditions are 12V DC of open voltage at receive mode (RX), and short current of 35mA at transmit mode (TX). ⑩INPUT RF input connector. Connect the coax jumper cable from the transceiver. ⑪CONT D-Sub (15pin) Socket. Connect the band data cable to the transceiver/ ⑫SERIAL Serial connector for control. (D-Sub 9pin) To access to CPU controller board through serial data bus. ⑬USB USB Connector. To access to CPU board. This socket in connected to serial connector ⑫. ⑭GND Ground terminal. ⑮AC IN 230V AC Main Socket. Socket for the AC power cord. (Socket is EMI filtered.) ⑯⑰Fuse A pair of fuses for AC Mains. 250V/20A glass fuse. -9- 7 LCD Panel Description LCD displays the status of the amp in various situations. Capacity is 24 characters in two rows. Basic Signs Following s are the common signs to appear while amp is in operation. *21MHz *28MHz 1.8MHz 3.5MHz 7MHz 10MHz 14MHz 18MHz 21MHz 24MHz 28MHz 50MHz EXCD BAND Manual AUT-CIV AUT-YAE AUT-KEN AUT-TEN AUT-ICM AUT-FLX AUT-ELC AUT-FRQ ANT-A ANT-B BAND SET MODE ANTENNA SELECT 1.8MHz AUT-CIV ANT-A STBY Temp35C OUT_Hi OPERATION STATUS STBY OPER ONAR TRCK TEMPERATURE (℃) OUTPUT SETTING Temp00C | Temp99C OUT_Hi OUT_Lo OUT_LoLIM Other Signs Initial Messages TOKYO HY-POWER HL-2500FX V1.00 PLEASE WAIT CHECKING CONDITIONS Protection Shutdown Message 24 MHz AUT-CIV ANT-A PROT BAND MISSET Detailed explanation will follow. ACV is 198V Complete Initial Set-Up - 10 - 8-A Basic Connection Following is a basic example of connection with the transceiver without using Band Data Cable. Antenna Caox. Cable HL-2500FX Transceiver AN TB ANT AN A REMOTE TUNER DC OUT 12V1A TB FUSE GN UT ALC SEND ALC ADJ FUSE SERIAL A SE L ND white 200VL 200VN GND black green Note ■SEND SEND socket is named “RELAY”, “TX GND”, “SEND” etc depending on radio models. (Refer to user manual of the transceiver.) ■ALC ALC cable must be connected especially when driving the amp with high power transceiver. Otherwise shut-down will frequently occur. - 11 - FUSE AC AC IN IN USB AC200V RCA plug cable FUSE CONT INPUT INP ANT SELECT 8-B Connection with Auto Tuner HC-1500AT Following illustration shows a connection example with ICOM radio(CI-V) and Tokyo Hy-Power HC1500AT, auto antenna tuner. HC-1500AT is equipped with such an advanced function as receiving various data (ex. Band data, SEND command etc.) from the radio and then passing them to the linear amp. Example below utilizes this feature. (Refer to the HC-1500AT manual for the details.) Rower cable Coax cable Antenna Coax cable HL-2500FX Transceiver ANT B ALC RELAY REMOTE TUNER DC OUT 12V1A FUSE FUSE FUSE FUSE ANT 3 ANT 2 CONT INPUT ANT REMOTE ANT ANT A SELECT GND SERIAL ALC ADJ ALC SEND AC ACININ USB ANT 1 HC-1500AT STBY OUT I N CIV OUTI N RCA plug cable RCA plug cable RCA plug cable Option : ICOM cable CI-V connection cable Note HL-2500FX can be combined with our HC-1.5AT, auto tuner as well. Connect TUNER socket of HL-2500FX to CONT’L socket of HC-1.5KAT. Interface technology of our original design enables the joint frequency band setting. DC power for HC-1.5KAT can also be fed from auxiliary DC supply (DC OUT 12V/2A) terminal of HL-2500FX. However, tuner will get “THRU (By-pass) mode when 50MHz is band set, as HC1.5KAT has no 50MHz position. - 12 - TRX KENWOOD IN OUT YAESUCONT DC12V 9 Operation 9-A Quick Learning / About Status Modes There are four operation status modes of STBY, OPER, ONAIR, and PROT. 1) STBY (Stand-by) Mode 1.8MHz AUT-CIV ANT-A STBY Temp35C OUT_Hi This is a status when POWER switch is only turned on. RF path is in THRU (or by-pass), and DC supply to FET drain is shut down. You may change BAND and other settings at this state. ON AIR FAN ID Pf/kW Pr/VD/ID/A LC OPER. OUTPUT HI POWER OFF STBY Pr PROT HF SOLID STATE LINEAR AMPLIFIER HL2500FX BAND ANT MAN’L AUTO 10 METER VD ID ALC LO 14 18/21 3.5 24/28 1.8 50 MAN’L 2) OPER (Operate) Mode This is a status when POWER switch is turned on, and OPER/STBY switch is tuned to OPER. RF path is in THRU, and amp is turned into ON-AIR, as the radio’s PTT is switched on. You may change BAND setting at this state. 1.8MHz AUT-CIV ANT-A OPER Temp35C OUT_Hi ON AIR FAN ID Pf/kW POWER Pr/VD/ID/A LC HF SOLID STATE LINEAR AMPLIFIER HL2500FX BAND ANT MAN’L AUTO 10 Pr OFF STBY CAUTION PROT METER VD ID ALC OPER. OUTPUT HI LO For your safety, the amp can not start up, if POWER switch is at OPER.Display below will appear. 14 18/21 3.5 24/28 1.8 50 MAN’L PSE STBY OPERSW! Turn to STBY once and turn to OPER again for reset. 3) ON-AIR(On-Air) Mode This is a status when transceiver’s PTT is switched on, while POWER is turned on and OPER/STBY switch is turned to OPER. The amp is ready to amplify the driving signal from the transceiver. You may not change BAND and other setting at this state. 1.8MHz AUT-CIV ANT-A ONAR Temp35C OUT_Hi ON AIR FAN ID Pf/kW Pr/VD/ID/A LC 送信 POWER METER ID VD OPER. OUTPUT HI PROT HF SOLID STATE LINEAR AMPLIFIER HL2500FX BAND ANT MAN’L AUTO 10 ALC Pr OFF STBY LO 14 18/21 3.5 24/28 1.8 50 MAN’L 4) PROT (Protection) Mode 1.8MHz AUT-CIV ANT-A PROT Over Heat This is a status when PROTECTION circuit has tripped to shut off the amplifier. RF path becomes THRU, and internal circuitry may be shut down according to kinds of protections. Detailed explanation will follow. ON AIR FAN ID Pf/kW Pr/VD/ID/A LC 送信 POWER METER VD ID ALC OPER. OUTPUT HI Pr OFF STBY LO PROT HF SOLID STATE LINEAR AMPLIFIER HL2500FX BAND ANT MAN’L AUTO 10 14 18/21 3.5 24/28 1.8 50 MAN’L - 13 - 9-B Quick Learning / About Basic Signs On LCD and LED Lamps 1) CB Band Inhibit The amp will shut down the transmission when driving signal of 26,000 through 27,999 (CB band) is detected due to FCC rule. When combining with ICOM and Kenwood radios, frequency data of operation is passed to CPU, even at RX state, to prohibit the transmission. EXCDMHz Is signed on LCD. (Freq. exceeded) With YAESU, Manual Band Set, Frequency Count Band Set With ICOM, KENWOOD EXCDMHz AUT-CIV ANT-A STBY Temp35C OUT_Hi When with Yaesu Radio, and with manual band set and freq. count band set methods, the amp transmission will be shut down when at TX 28 MHz AUT-YAE ANT-A PROT INHIBIT FREQ EEE FREQ PROT INHIBIT will appear on LCD. 2) OPER. MODE Switch The amp will be shut down, if POWER switch is turned on, while OPER/STBY is set at OPER. PSE STBYEOPERSW! To reset, switch OPER. off and on. This is to avoid unintended sudden transmission, for your safety LCD message PSE STBY OPERSW! 3) TRACK Sign TRACK (Tracking) sign will appear, when the BAND changes , for a short period of 0.2 sec. This indicates that band frequency data is being sent over to combined auto tuner. 3.5 MHz AUT-CIV ANT-A TRCK Temp35C OUT_Hi 4) ID Lamp ID lamp lights when FET drain currents exceeds 55A, and is a kind of peak current indicator. It is not a problem, if it lights only at a voice peak (SSB). ON AIR FAN ID PROT 5) FAN Lamp The cooling speed changes in proportion to the variation of internal temperature. As the ONAIR time gets longer , It is normal if fan noise sounds louder and FAN lamp to light brighter. ON AIR FAN ID PROT - 14 - 9-C Quick Learning / About TX Trial We recommend for you to run a trial operation, at first, under the Manual Band Set mode (without band data cable connected to radio). With this trial, you can check if antenna, cables, and AC power line are in a proper condition. In case you encounter any trouble under Auto Band Set connection, later, you could return to this trial mode to see where the cause of trouble is. 1) Setting Before Power ON Transceiver Front Panel ・POWER=OFF ・ OPER=OFF (STBY) ・Mode=CW (or RTTY) ・RF POWER LEVEL=Minimal ・ OUTPUT=HI ・ BAND=MANU‘L ・(Others=Any as needed) Rear Panel ・ALC=C.C.W (Fully counter clock-wise) ・Select=Any position REMOTE SELECT ANT A DC OUT 12V1A TUNER ANT B FUSE FUSE CONT INPUT ALC ADJ ALC GND FUSE FUSE SERIAL SEND AC IN USB ON AIR FAN ID Pf/kW PROT Pr/VD/ID/ALC HF SOLID STATE LINEAR AMPLIFIER HL-2500FX POWER OPER. OUTPUT VD HI METER ID ANT ALC BAND AUTO Pr OFF STBY LO MAN’L 10 14 18/21 3.5 24/28 1.8 50 MAN’L Any position 2) Powering ON Turn the POWER on and the amp will start to execute initial self-check, Following messages will appear on LCD until status reaches normal operation mode. ON AIR FAN ID Pf/kW PROT Pr/VD/ID/ALC HF SOLID STATE LINEAR AMPLIFIER HL-2500FX POWER OPER. OUTPUT VD HI METER ID ANT ALC BAND AUTO Pr OFF Signs Initial Sign PLEASE WAIT CHECKING CONDITIONS Checking 14 18/21 3.5 24/28 1.8 50 MAN’L ACV is 198V Normal MODE Complete Initial Set-Up Checking Over After turning POWER switch on, MPU chip will check to see if AC line voltage is usable for the amplifier. 1sec 1.8MHz Manual ANT-A STBY Temp35C OUT Hi LO MAN’L NOTE TOKYO HY-POWER HL-2500FX V1.00 1sec 1sec STBY 10 Operation Ready - 15 - 9-C Quick Learning / About TX Trial 3)Band Setting Set the freq. BAND as desired for both transceiver and HL-2500FX. (Ex.: 14MHz) ON AIR 14MHz FAN ID Pf/kW PROT Pr/VD/ID/ALC HF SOLID STATE LINEAR AMPLIFIER HL-2500FX POWER OPER. OUTPUT VD HI METER ID ANT ALC BAND AUTO Pr OFF STBY LO 10 MAN’L 24/28 1.8 50 MAN’L NOTICE When the BAND switch is turned under Man’l Set mode, selected BAND will shift as follows: ・If turned clock-wise, BAND will shift in the order of 14⇒21⇒28⇒50MHz. ・And if BAND is turned back, counter clock-wise, BAND will shift in the order of 50⇒24⇒18⇒14MHz. BAND MAN’L 10 3.5 1.8 1.8MHz ↓ 3.5MHz ↓ 7MHz ↓ 10MHz ↓ 14MHz ↓ 21MHz ↓ 28MHz ↓ 50MHz Example C.C.W. 14 18/21 24/28 50 BAND MAN’L 10 3.5 1.8 50MHz ↓ 24MHz ↓ 18MHz ↓ 14MHz ↓ 10MHz ↓ 7MHz ↓ 3.5MHz ↓ 1.8MHz - 16 - 14 18/21 24/28 50 14 18/21 3.5 14 MHz Manual ANT-A STBY Temp35C OUT Hi C.W. 設定 If you are shifting up from 14 to 18, you have to turn to 24/28 once, and then turn back to 18/21. BAND MAN’L 10 3.5 1.8 14 18/21 24/28 50 BAND MAN’L 10 3.5 1.8 14 18/21 24/28 50 BAND MAN’L 10 3.5 1.8 14 18/21 24/28 50 9-C Quick Learning / About TX Trial 4) Switching to OPER At OPER. (Operate Mode) status, the amp is ready to run together with combined transceiver. ON AIR FAN ID Pf/kW PROT Pr/VD/ID/ALC HF SOLID STATE LINEAR AMPLIFIER HL-2500FX POWER OPER. OUTPUT VD HI METER ID ANT ALC BAND AUTO Pr OFF STBY LO 10 MAN’L 14 18/21 3.5 24/28 1.8 50 MAN’L 14 MHz Manual ANT-A OPER Temp35C OUT Hi 5) Transmitting Key (RTT) the transceiver with CW (or RTTY) carrier. The amp is driven to transmit. CW (or RTTY) ON AIR FAN ID Pf/kW PROT Pr/VD/ID/ALC HF SOLID STATE LINEAR AMPLIFIER HL-2500FX POWER OPER. OUTPUT VD HI METER ID ANT ALC BAND AUTO Pr OFF STBY LO 10 MAN’L 14 18/21 3.5 24/28 1.8 50 MAN’L 14 MHz Manual ANT-A ONAR Temp35C OUT Hi 6) Increasing Output Adjusting the knob of transceiver ‘s RF LEVEL, increase output level to desired value. (1,500W is maximum limit on HF, and 1,000W on 50MHz. Observe reflection from antenna and RFI (interference) to nearby home appliance. Insert multiple number of clamp-on ferrite cores respectively to every coax cable s as well as various control and grounding cables around the amp and the transceiver. ON AIR FAN CW (or RTTY) ID Pf/kW PROT Pr/VD/ID/ALC HF SOLID STATE LINEAR AMPLIFIER HL-2500FX POWER Output Level OPER. OUTPUT VD HI METER ID ANT ALC BAND AUTO Pr OFF STBY LO 10 MAN’L 24/28 1.8 50 MAN’L 14 MHz Manual ANT-A ONAR Temp35C OUT Hi - 17 - 14 18/21 3.5 9-C Quick Learning / About ALC Adjustment 7) ALC Adjustment ALC helps the amp keep its output power at desired level. ALC is effective to avoid overdriving of the amp, especially when high power transceiver is combined. When adjusting ALC, use a dummy load of 2kW capacity, and /or a good antenna with SWR of 1:1 or less. ① “ALC ADJ” pot should be, at first, turned fully counter clock-wise. ② Select desired freq. band and CW (or RTTY) mode. ③ Increase the driving power from the radio so that required output power is achieved from the amp. ④ Carefully increase further the drive until five to ten percent increase is obtained for output. ⑤ Turn “ALC ADJ” pot clock-wise carefully so that output gradually decreases, to reach desired level. (For more details, see “Hints and Tips of ALC, www.tokyohypower.com) REMOTE SELECT DC OUT 12V1A TUNER ANT A ANT B FUSE FUSE CONT INPUT GND FUSE FUSE ALC ADJ SERIAL ALC SEND AC IN USB - 18 - 10 Operation / Setting 10-A With ICOM (CI-V) Connect twin RCA plug cable (included in the package), and optional ICOM band data cable as shown in the figure below. Set AUTO/MAN’L switch to AUTO position and select ICOM with SELECT switch located on the rear panel. AUTO-CIV will be displayed on LCD panel. Set the CI-V menu of ICOM radio as shown below, and HL-2500FX will follow the band of ICOM radio. To Antenna Connection Coax Cable HL-2500FX SELECT REMOTE ANT ANT A TUNER DC OUT 12V1A INPUT INPUT CONT ICOM Transceiver ANT A FUSE ANT ALC RELAY REMOTE GND FUSE SERIAL ALC ADJ ALCSEND FUSE FUSE AC AC IN IN USB AC200V Single Phase RCS plug cable White Black Green 200V-L 200V-N GND (Option) ICOM Band Cable Switch Setting REMOTE SELECT ANT A 14 MHz AUT-CIV ANT-A STBY Temp35C OUT Hi DC OUT 12V1A TUNER ANT B FUSE FUSE CONT INPUT ALC ADJ ALC GND FUSE FUSE SERIAL SEND AC IN USB ON AIR FAN ID Pf/kW PROT Pr/VD/ID/ALC HF SOLID STATE LINEAR AMPLIFIER HL-2500FX ICOM POWER OPER. OUTPUT VD HI METER ID ANT ALC BAND AUTO Pr OFF STBY LO Setting of ICOM CI-V Menu CI-V BAUD RATE: 9600 [bps] CI-V ADDRESS: 5Ch CI-V Transceiver: ON CI-V with IC-731: OFF ※Refer to ICOM’s instruction manual for CI-V details. - 19 - MAN’L 10 MAN’L 14 18/21 3.5 24/28 1.8 50 10 Operation / Setting 10-B With YAESU Connect twin RCA plug cable (included in the package) and optional YAESU band data cable as shown in the figure below. Set AUTO/MAN’L switch to AUTO position and select YAESU with SELECT switch located on the rear panel. AUT-YAE will be displayed on LCD panel , and HL-2500FX will follow the band of Yaesu radio. Connection To Antenna Coax Cable HL-2500FX YAESU ANT ANT A ANT B SELECT REMOTE TUNER DC OUT 12V1A FUSE BAND DATA ANT EXT_ALC FUSE CONT INPUT INPUT GND FUSE FUSE SERIAL ALC ADJ ALCSEND TXGND AC IN AC IN USB AC200V Single Phase RCA plug cable White Black Green 200V-L 200V-N GND YAESU Band Data Cable Switch Setting REMOTE SELECT ANT A 14 MHz AUT-YAE ANT-A STBY Temp35C OUT Hi DC OUT 12V1A TUNER ANT B FUSE FUSE CONT INPUT ALC ADJ ALC GND FUSE FUSE SERIAL SEND AC IN USB ON AIR FAN ID Pf/kW PROT Pr/VD/ID/ALC YAESU HF SOLID STATE LINEAR AMPLIFIER HL-2500FX POWER OPER. OUTPUT VD HI METER ID ANT ALC BAND AUTO Pr OFF STBY LO 10 14 18/21 24/28 1.8 50 MAN’L Setting of Transceiver Some Yaesu models require initial settings for maximum output and T/R relay (TX GND) output. Refer to the user manual for details. - 20 - MAN’L 3.5 10 Operation / Setting 10-C With KENWOOD Prepare a control cable for PTT(SEND) and ALC. One end should be DIN plug for REMOTE of Kenwood radio. The other end should be two RCA jacks of the amp. (Refer to Kenwood manual for REMOTE socket pin assignment.) Set AUTO/MAN’L switch to AUTO position and select KENWOOD with SELECT switch located on the rear panel. AUT-KEN will be displayed on the LCD panel, and HL-2500FX will follow the band of Kenwood radio. Band Data Cable Connection To Antenna Coax Cable HL-2500FX トランシーバ COM REMOTE TUNER DC OUT 12V1A FUSE REMOTE ANT EXT_ALC ANT ANT A ANT B SELECT FUSE CONT INPUT INPUT GND FUSE FUSE SERIAL ALC ADJ ALC SEND TXGND AC AC IN IN USB AC200V Single Phase 200V-L 200V-N GND RCA Plug Cable (ALC/SEND) (Not included) White Black Green Switch Setting REMOTE SELECT ANT A 14 MHz AUT-KEN ANT-A STBY Temp35C OUT Hi FUSE FUSE ON AIR CONT INPUT GND FAN ALC ADJ Pf/kW ALC ID FUSE FUSE SERIAL SEND PROT Pr/VD/ID/ALC KENWOOD DC OUT 12V1A TUNER ANT B AC IN USB HF SOLID STATE LINEAR AMPLIFIER HL-2500FX POWER OPER. OUTPUT VD HI METER ID ANT ALC BAND AUTO Pr OFF Setting of Transceiver Baud Rate :9600[bps] Stop Bit :1bit ※Refer to Kenwood manual for details. - 21 - STBY LO MAN’L 10 MAN’L 14 18/21 3.5 24/28 1.8 50 10 Operation / Setting 10-D With ELECRAFT(K3) Connect included twin RCA plug cable and optional Elecraft band data cable as shown in the figure below. Set AUTO/MAN’L switch to AUTO position and select ELECRAFT with SELECT switch located on the rear panel. AUT-ELC will be displayed on LCD panel and HL-2500FX will follow the band of K3 radio. Band Data Cable Connection EBC-2.4K/K3 To Antenna Coax Cable HL-2500FX ELECRAFT(K3) ANT B SELECT REMOTE ANT ANT A TUNER DC OUT 12V1A INPUT INPUT CONT FUSE ACC KEY OUT GND FUSE FUSE FUSE SERIAL ALC ADJ ALC SEND AC AC IN IN USB SEND ALC AC200V Single Phase ALC White Black Green 200V-L 200V-N GND Switch Setting RCA Plug Cable REMOTE SELECT ANT A 14 MHz AUT-ELC ANT-A STBY Temp35C OUT Hi DC OUT 12V1A TUNER ANT B FUSE FUSE CONT INPUT ALC ADJ ALC GND FUSE FUSE SERIAL SEND AC IN USB ON AIR FAN ID Pf/kW PROT Pr/VD/ID/ALC HF SOLID STATE LINEAR AMPLIFIER HL-2500FX ELECRAFT(K3) POWER OPER. OUTPUT VD HI METER ID ANT ALC BAND AUTO Pr OFF STBY LO Setting of Transceiver Setting of “DONFIG menu” is required for K3transceiver. (Refer to K3 manual for details). - 22 - MAN’L 10 MAN’L 14 18/21 3.5 24/28 1.8 50 10 Operation / Setting 10-E Frequency Count Method When there is no way of auto band-set connection between the transceiver and the amplifier and or when it is desired to make mutual band connection simple, auto band-set-operation is feasible utilizing the frequency counting feature built in this amplifier. Set AUTO/MAN’L switch to AUT-FRQ with SELECT switch located on the rear panel. AUT-FRQ will be displayed on LCD panel and the amp will set the band automatically reading the frequency of driving signal . If the transceiver is keyed, the amplifier will set the operating band automatically by reading the frequency of driving signal. CAUTION There is a time delay of 20 milli-sec from RX to TX state change under this method. Full break-in CW is not available with this method, for this reason. To Antenna Connection Coax Cable HL-2500FX Transceiver ANT ANA AN TB SELECT REMOTE TUNER DC OUT 12V1A TA FUSE INPUT INP ANT GN UT ALC SEND ALC ADJ FUSE CONT FUSE FUSE SERIAL A SE L ND AC AC IN IN USB AC200V RCA Plug Cable White Black Green 200V-L 200V-N GND REMOTE SELECT Switch Setting ANT A ANT B 14 MHz AUT-FRQ ANT-A STBY Temp35C OUT Hi DC OUT 12V1A TUNER FUSE FUSE CONT INPUT ALC ADJ ALC GND FUSE FUSE SERIAL SEND AC IN USB ON AIR FAN ID Pf/kW PROT Pr/VD/ID/ALC ICOM HF SOLID STATE LINEAR AMPLIFIER HL-2500FX POWER OPER. OUTPUT VD HI METER ID ANT ALC BAND AUTO Pr OFF Setting of Transceiver There is nothing required in particular. - 23 - STBY LO MAN’L 10 MAN’L 14 18/21 3.5 24/28 1.8 50 11 Protection Circuit 11-A Interlock Protection ★ “Interlock” is built in for the safety of operator, avoiding the unexpected accidents from electric and thermal shocks. All power shut down. No sign. Sign Status Main DC P. Supply (Vdd) AC Magnet Relay RF path Fan Control ON AIR FAN ID Pf/kW PROT Pr/VD/ID/ALC Shut down Shut down Shut down Shut down HF SOLID STATE LINEAR AMPLIFIER HL-2500FX POWER OPER. METER ID OUTPUT HI VD ALC ANT BAND AUTO Pr OFF STBY LO 10 MAN’L Reset 14 18/21 3.5 24/28 1.8 50 ①Fix top cover securely ②Cool off the amplifier sufficiently MAN’L 1) Cover Interlock When the top cover is removed, cover switch is activated to shut down AC power line. (POWER Lamp, LCD panel, cooling fan are all turned off.) 2) Temperature Interlock When the internal temperature of the amp reaches 90℃, AC power line is shut down. (POWER Lamp, LCD panel, cooling fan are all turned off.) In case all the lamps go off suddenly while transmitting , stop the transmission, unplug AC cord, and wait for five minutes. Check if AC main fuses are blown, or if the temp. inter-lock has been activated. REMARKS Location of Interlock Switch Interlock Switch Power Supply Front Side Rear Side The amp temperature is normally checked by thermal sensor and microprocessor. “FAULT” temp protection is usually switched on in prior to Temp. Interlock to turn on, the amp may have been heated by other heat source and or microprocessor is in failure. - 24 - 11-B Fault Protection FAULT PROTECTION Fault Protection is built in to avoid the damage to the amp due to the severe cause of fault within the amplifier or on the AC power line. PROT lamp glows. Message is displayed Sign Status Main DC P. Supply AC Magnet Relay RF Path Fan Control 1.8MHz AUT-CIV ANT-A PROT OVER TEMP Shut Down Shut Down Thru ON Protection Sign Reset ON AIR FAN ID Pf/kW POWER Pr/VD/ID/A LC PROT HF SOLID STATE LINEAR AMPLIFIER HL2500FX BAND ANT MAN’L AUTO 10 14 18/21 METER VD ID ALC OPER. OUTPUT HI Pr OFF STBY LO 3.5 24/28 1.8 50 Set OPER/STBY switch to STAND-BY position, and turn POWER switch off and on. MAN’L List of Fault Protection Prot. LCD Sign Description Remedy Over Heat FAULT OVER TEMP Heat sink temp reached 95℃ Cool off to reset Fan Faulty FAULT FAN FAIL FAN faulty or speed too low Repair at factory AC Line High FAULT OVER LINE VOLT AC line exceeded 250V Check AC line AC Line Low FAULT UNDER LINE VOLT AC line fell to 85V or lower Check AC line Fuse Blown FAULT FUSE BLOW Internal fuse blown Refer to Pxxx Main P.S. Faulty FAULT DC SUPPLY OUT Output of main DC P.S. (Vdd) faulty Repair at factory Main P.S. Faulty FAULT DC SUPPLY Primary side of main DC P.S. faulty Repair at factory - 25 - 11 Protection Circuit 11-C Protection / Slight Fault Another group of protection circuits are provided to shut down the transmission when the other faults occur within the amp. PROT lamp glows. Message is displayed Sign Status Main DC P. Supply (Vdd)) AC Magnet Relay RF Path FAN・Control Circuit 1.8MHz AUT-CIV ANT-A PROT CROWBAR On ON Thru ON Protection Sign Reset ON AIR FAN ID Pf/kW POWER Pr/VD/ID/A LC METER ID VD ALC OPER. OUTPUT HI Pr OFF STBY PROT HF SOLID STATE LINEAR AMPLIFIER HL2500FX BAND ANT MAN’L AUTO 14 10 18/21 LO 3.5 24/28 1.8 50 Switch “OPERATE/STBY” off and on. MAN’L List of PROT Prot. LCD Sign Description Re-adjust ALC Over Out put Power PROT OVER POWER RF output power exceeded 1,500W Re-adjust ALC Inhibit Freq. PROT INHIBIT FREQ CB band freq.(26,000~27,999MHz) detected Check x-ceiver Reflected Power PROT OVER Pr Power reflection from antenna exceeded 150W Check antenna Over Current PROT OVER CURRENT FET drain current (Id) exceeded 70A Check antenna Re-adjust ALC Over Dissipation PROT OVER Ploss FET drain dissipation (Pd) exceeded 2,000W Tj Over PROT OVER Tj FET junction temperature exceeded 190℃ Over Drive PROT OVER DRIVE RF drive power exceeded 150W Readjust ALC, decrease RF drive from X-ceiverf Unbalance PROT COMB HEAT PA combiner temperature exceeded 70℃ Check antenna SWR Contact factory *Crowbar PROT CROWBAR Crowbar prot. Circuit switched on See below Band Misset PROT BAND MIS-SET Band set incorrect., PA failed Check band setting Contact factory - 26 - 11 Protection Circuit 11-C Protection / Slight Fault Crowbar When the FET drain current and reflected power from antenna significantly exceed the limit, crowbar circuit trips instantly to protect valuable FET finals, without waiting for the response from the microprocessor. It blanks the RF drive for 100ms. During this time period, microprocessor detects the abnormal states to issue shut down command under “PROT CROWBER”. - 27 - 11 Protection Circuit 11-D Protection / Reduced Power Operation If slight failure occur such as “over current”, for example, while working under OUT=Hi mode (High output mode), the amp is not necessarily shut down, but enters into reduced power operation mode Sign Status Following message displayed Main DC P. Supply (Vdd)) AC Magnet Relay RF path Output Setting) FAN, control circuit 1.8MHz AUT-CIV ANT-A ONAR Temp35C OUT_LoLIM Low Voltage Applied ON ON (Amplifying) Lo(Low Vd) ON Reset ON AIR FAN ID Pf/kW POWER Pr/VD/ID/A LC METER VD ID ALC OPER. OUTPUT HI Pr OFF STBY LO PROT HF SOLID STATE LINEAR AMPLIFIER HL2500FX BAND ANT MAN’L AUTO 10 14 18/21 3.5 24/28 1.8 50 Release PTT (to RX) once, and key (to TX) again. MAN’L List of Protection Protection LCD Sign Description Remarks Sight Over Current Drain current (Id) exceeded 55A for 60sec When exceeding 70A, PROT shuts down immediately Slight Over Heat Heat sink temp. exceeded 75℃ When exceeding 95℃,FAULT PROT shuts down Total FET drain dissipation exceeded 2,000W If 2,000W exceeded, even reduced power mode, PROT shuts down FET junction temp (Tj) exceeded 190℃ If Tj keeps 90℃, even with reduced power mode, PROT shuts down Over Dissipation Over Tj OUT: LoLim 12 Technical Information about Various Connectors 12-A CONT Connector (Control) Various control signals are concentrated in this connector. (D-SUB 15pin Connector, Female) Pin Assignment Pin # Signal Description Remarks +12V Auxiliary DC P. Supply +12V0.1A Never short +5V Auxiliary DC P. Supply +5V0.1A Never short RXD Serial Comm. Port (RX) For EIA232_TRX 10 TXD Serial Comm. Port (TX) For EIA232_TRX BDY0 YAESU Band Data Input 0bit With pull-up resistor 11 BDY1 YAESU Band Data Input 1bit With pull-up resistor BDY2 YAESU Band Data Input 2bit With pull-up resistor 12 BDY3 YAESU Band Data Input 3 bit With pull-up resistor GND Signal Ground 13 AN-IC ICOM Analog Freq. Info. IN AN-IC-G ICOM Analog Freq. Info. Gnd 14 T/R T/R(SEND) IN GND Signal Ground 15 CIV-T ICOMCI-V TX Port CIV-R ICOMCI-V RX Port Connector in parallel with “SEND” 12-B TUNER Connector For connector to THP HC-1.5KAT, and HC-1500AT tuners. (DIN 7pin Connector, Female, Hoshiden TCS4470-0140577) Pin # Signal Description GND Signal Ground EVENT Event IN (FREQ request signal) FREQ Freq. Information OUT 1・3・5・6 No Connection - 29 - Remarks FREQOUT=MHz/1000 12 Technical Information About Various Connectors 12-C CONT Connect (Control) Serial connector for utility use (D-SUB 9pin Connector, Female) Pin Assignment Pin # Signal Description Remarks RD RX Signal For straight cable TD TX Signal For straight cable GND Signal Ground Others No Connection Note This connector is for utility use, and can not be connected to the transceiver. It is a different one from TD/RD of CONT connector. 12-D DC12V Connector Auxiliary DC power supply of DC12V2A capacity. Suitable for feeding auto tuner. (Type SMPo3V by Nichiatsu) Pin Assignment Pin # Signal DC12V Description Auxiliary DC P.S.12V2A No connection GND Return - 30 - Remarks 12 Technical Information About Various Connectors 12-E REMOTE Connector For controlling the amplifier from the remote location. (Type SMP04V by Nichiatsu) Pin Assignment Pin # Signal Description WAKE-UP+ Start up voltage IN+ WAKE-UP- Start up voltage IN- OPER_EXT External OPER Input GND Signal GND Note Note : Please refer to “Remote Controlled Operation” Section. - 31 - Remarks Start up when DC12V applied. (DC12V100mA) To enter “Operate” when pin 3 grounded (15mA). 5V, when Open 12 Technical Information about Various Connectors 12-F About SEND Interface Circuit +12V 1kΩ To relay Relay To control circuit TX/RX switch terminal (SEND socket) is controlled through photo-MOS relay rather than thru direct relay switching. Open voltage is +12V, and draws 10ma when grounded. When PROTECTION trips, photo-MOA relay for TX Inhibit becomes open and TX is shut down From TX inhibit SEND(RCA) CONT14pin 12-G ALC Interface Circuit When the sum of forward output power (voltage) and reflected output power (voltage) exceeds the programmed ALC level, negative voltage is produced at ALC terminal. ALC circuit consists of an Ope-amp, and it is preferable that input port of the transceiver for the external ALC voltage has an input impedance of 10K Ω minimum. Maximum ALC output of -10V is usually produced. Some of old fashioned radio may require higher voltage. Built-in gain switch needs switched in that case. 12-H About ICOM CI-V Interface Circuit 10 11 12 13 14 15 CI-V signal lines are connected to pins 7, 8 and 15 of CONT Connector. CONT 3.5mmPHON O PULG - 32 - 12 Technical Information about Various Connectors 12-I About YAESU and K3 Interface Circuit Four bits of band data (A to D) are connected to CONT connector as illustrated. CONT 10 BAND A BAND B BAND C BAND D GND 11 12 13 This interface is used for Elecraft K3 as well. 14 15 12-J About KENWOOD Interface Circuit CONT 10 11 12 13 Kenwood uses TD/RD pins of CONT connector for EIA232C based serial communication. Loop back wiring for pin 7 and 8 is required at Kenwood connector side. 14 15 12-H ICOM(BAND VOLTAGE)Interface Circuit 10 11 12 14 15 ICOM ACC2 Connector 13 CONT BAND GND - 33 - 13 Maintenance 13-A How to remove the top cover To remove the top cover, unscrew nine M3 bolts and eight M4 bolts on the upper surface, as well as six each M3 bolts at right and left surfaces of the cover. Inter-Lock Upper Surface M3x6 9(Black) M4x8 8(Red) Left surface Right surface M3x6 6 M3x6 6 Lift the cover carefully. CAUTION Inter-Lock switch is located. ON AIR FAN Widen ID Pf/kW PROT Pr/VD/ID/ALC HF SOLID STATE LINEAR AMPLIFIER HL-2500FX Widen POWER OPER. BAND METER OUTPUT VD HI ID ANT ALC AUTO 10 Pr OFF STBY LO - 34 - MAN’L MAN’L 14 18/21 3.5 24/28 1.8 50 13 Maintenance 13-B How to replace Fuses Variety of fuses are built in the amplifier. Fuses are consumption item, and may melt to blow, as time passes by even if there is no failure in the circuit. Q’ty Fuse Name and Location Specs/Rating Problem when blown Possible Cause AC Fuse AC Primary Line 250CF6.3x32 250V20A (Fast attack) Do not power on Over output Power supply failure PA DC Fuse PA drain #1197(Low Profile) Fuse, 58V20A “FAULT FUSE BLOW” Over current PA Failure DC Fuse Control circuit LM3.2 30V3.2A by Daito Micro Fuse Do not power on CONT terminal short Control circuit failure DC Fuse Auxiliary DC P.S. LM3.2 30V3.2A Daito Micro Fuse No12V output (External tuner not work) DC output terminal short RF Input Prot. Fuse RF Input LM1.6 30V1.6A by Daito Micro Fuse No RF output from amp Over drive REMOTE SELECT DC OUT 12V1A ANT A ANT B TUNER FUSE AC Fuse FUSE CONT INPUT GND FUSE ALC ADJ FUSE SERIAL ALC SEND AC IN USB - 35 - 13 Maintenance 13-C Fuse Location DC Fuse /PA FET Drain DC58V20A(Yellow) x3 T/R Relay Box L.P.F. RF Power Combiner Drain Vdd P.S. 1 Control DC P.S. DC Fuse (Control circuit DC 3.2A (Black) and12V DC P.S. Drain Vdd P.S. PA Control Circuit Board RF Power Splitter - 36 - RF Input Prot Fuse 1.6A (Black) 14 Block Diagram and Explanation of Major Circuitry 14-A RF Amp Driving RF signal transmitted from the transceiver is lead to the ATT/ Limitter board via T/R-Assy unit, where there is 3dB attenuator as well as RF limiter. These circuitry properly levels the magnitude of RF signal and also instantly shuts down the input to protect the amplifier. There is a three port splitter located in this board that sprits a driving signal equally into three components, which are then fed to final PA module. Operating status of three PA’s are strictly monitored in the combiner stage with regard to heat balancing of respective amps. Finally 1,500W of RF output is lead to LPF (low pass filter) unit, where harmonics and spurious signals are reduced to FCC rules. Filtered output signal is sent to T/R ASSY unit again and is lead to antenna terminal by way of antenna relay. PA module consists of three sets of wide band class AB1 linear amp. using THP2933 FET’s in the push-pull form. 500W is achieved per one basic amp. board. Then the three outputs from the PA module is sent to the combiner unit, where three 500W components are combined to become 1,500W. - 37 - 14 Block Diagram and Explanation of Major Circuitry 14-B DC Power Supply 14-C Control Circuit AC power is received at the IEC socket intake and passes the line filter. There are safety fuses on both lines. There are control power supply and FET drain power supply . Start up is usually made by turning on and off of control power supply. DC 12V, 24V and 100V are available when control power supply is turned on, and are always outputted once the POWER is turned on. Control circuit performs various control using micro-processor PIC18F8722 chip. Also, basic interface meet the necessary rules and conditions using the specialized semiconductor devices. There are a magnet relay at primary side and DC ON/OFF function at secondary side. Depending on the operating condition, this power supply is turned on and off through the control circuit, and is provided in this power supply to meet IEC61000-3-2 harmonics regulation. - 38 -
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 39 Author : Creator : PScript5.dll Version 5.2 Producer : Justsystem PDF Creator v3.1.1543 Create Date : 2013:06:18 09:31:54-09:00 Title :EXIF Metadata provided by EXIF.tools