Trane H V Wshp 5 To 25 Tons Installation And Maintenance Manual Axiom Horizontal/Vertical Water Source Comfort System S GEH GEV; SVX01N EN September 2014
2015-04-02
: Trane Trane-H-V-Wshp-5-To-25-Tons-Installation-And-Maintenance-Manual-684244 trane-h-v-wshp-5-to-25-tons-installation-and-maintenance-manual-684244 trane pdf
Open the PDF directly: View PDF .
Page Count: 132
Download | |
Open PDF In Browser | View PDF |
Installation, Operation, and Maintenance Water Source Heat Pump Axiom™ Horizontal/Vertical GEHE/GEVE, EXHF/EXVF ½ to 25Tons, 50/60 Hz Model Numbers GEHE 006-060 - 50/60 Hz GEHE 072-120 - 50/60 Hz EXHF 006-070 - 60 Hz GEVE 006-060 - 50/60 Hz GEVE 072-300 - 50/60 Hz EXVF 006-070 - 60 Hz SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. September 2014 WSHP-SVX01N-EN Introduction Read this manual thoroughly before operating or servicing this unit. Warnings, Cautions, and Notices Safety advisories appear throughout this manual as required.Your personal safety and the proper operation of this machine depend upon the strict observance of these precautions. The three types of advisories are defined as follows: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous CAUTIONs situation which, if not avoided, could result in minor or moderate injury. It could also be used to alert against unsafe practices. WARNING NOTICE WARNING Proper Field Wiring and Grounding Required! Failure to follow code could result in death or serious injury. All field wiring MUST be performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field wiring installation and grounding as described in NEC and your local/state electrical codes. WARNING Personal Protective Equipment (PPE) Required! Installing/servicing this unit could result in exposure to electrical, mechanical and chemical hazards. • Before installing/servicing this unit, technicians MUST put on all PPE required for the work being undertaken (Examples; cut resistant gloves/sleeves, butyl gloves, safety glasses, hard hat/bump cap, fall protection, electrical PPE and arc flash clothing). ALWAYS refer to appropriate Material Safety Data Sheets (MSDS)/Safety Data Sheets (SDS) and OSHA guidelines for proper PPE. • When working with or around hazardous chemicals, ALWAYS refer to the appropriate MSDS/SDS and OSHA/GHS (Global Harmonized System of Classification and Labelling of Chemicals) guidelines for information on allowable personal exposure levels, proper respiratory protection and handling instructions. • If there is a risk of energized electrical contact, arc, or flash, technicians MUST put on all PPE in accordance with OSHA, NFPA 70E, or other country-specific requirements for arc flash protection, PRIOR to servicing the unit. NEVER PERFORM ANY SWITCHING, DISCONNECTING, OR VOLTAGE TESTING WITHOUT PROPER ELECTRICAL PPE AND ARC FLASH CLOTHING. ENSURE ELECTRICAL METERS AND EQUIPMENT ARE PROPERLY RATED FOR INTENDED VOLTAGE. Indicates a situation that could result in equipment or property-damage only accidents. Important Environmental Concerns Scientific research has shown that certain man-made chemicals can affect the earth’s naturally occurring stratospheric ozone layer when released to the atmosphere. In particular, several of the identified chemicals that may affect the ozone layer are refrigerants that contain Chlorine, Fluorine and Carbon (CFCs) and those containing Hydrogen, Chlorine, Fluorine and Carbon (HCFCs). Not all refrigerants containing these compounds have the same potential impact to the environment.Trane advocates the responsible handling of all refrigerants-including industry replacements for CFCs such as HCFCs and HFCs. Important Responsible Refrigerant Practices Trane believes that responsible refrigerant practices are important to the environment, our customers, and the air conditioning industry. All technicians who handle refrigerants must be certified.The Federal Clean Air Act (Section 608) sets forth the requirements for handling, reclaiming, recovering and recycling of certain refrigerants and the equipment that is used in these service procedures. In addition, some states or municipalities may have additional requirements that must also be adhered to for responsible management of refrigerants. Know the applicable laws and follow them. © 2014Trane All rights reserved Failure to follow instructions could result in death or serious injury. WSHP-SVX01N-EN Introduction Copyright This document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part without written permission.Trane reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or change. Trademarks All trademarks referenced in this document are the trademarks of their respective owners. Axiom, ReliaTel,TOPSS,Tracer,Trane, and theTrane logo are trademarks or registered trademarks ofTrane in the United States and other countries.Trane is a business of Ingersoll Rand. All trademarks referenced in this document are the trademarks of their respective owners. LonTalk is a registered trademark of Echelon Corporation. BACnet is a registered trademark of ASHRAE. Revision History WSHP-SVX01N-EN (12 Sep 2014) • Edited Model Number, Electrical Data, Fan Performance - 2 speed motor change WSHP-SVX01N-EN 3 Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Warnings, Cautions, and Notices . . . . . . . . 2 Supply/Return Pipe Connections . . . . . . .60 Important Environmental Concerns . . . . . 2 Cleaning and Flushing the Water Loop . .61 Important Responsible Refrigerant Practices 2 Field Installed Power Wiring . . . . . . . . . . .61 Types of Hose Connections . . . . . . . . . . . .60 Main Unit Power Wiring . . . . . . . . . . . . . .61 Copyright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Control Power Transformer . . . . . . . . . . .62 Model Number Description . . . . . . . . . . . . . . . 5 ½ to 5 Ton . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Thermostat Location . . . . . . . . . . . . . . . . .62 Controls Using 24 VAC . . . . . . . . . . . . . . .62 Model Number Description . . . . . . . . . . . . . . . 6 6 to 25 Ton . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Blower Motor Speed-Tap Retrofit . . . . . . .63 Model Number Description . . . . . . . . . . . . . . . 7 ½ to 6 Ton . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Air Flow Adjustment . . . . . . . . . . . . . . . . .64 Overview of Manual . . . . . . . . . . . . . . . . . . . . . 8 Unit Nameplate . . . . . . . . . . . . . . . . . . . . . 8 Waterside Economizer Installation for GEH and GEV 6 to 25 Ton Models . . . . . . . . . . .68 Compressor Nameplate . . . . . . . . . . . . . . . 8 Waterside Economizer Start-Up Sequence .70 Model Number Description . . . . . . . . . . . . 8 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . .72 General Information . . . . . . . . . . . . . . . . . . . . . 9 Pre-Start Checklist . . . . . . . . . . . . . . . . . . . . . . .92 Pre-Installation . . . . . . . . . . . . . . . . . . . . . . . . . 13 Unit Inspection Checklist . . . . . . . . . . . . . 13 Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93 Initial Unit Start-up . . . . . . . . . . . . . . . . . . . .93 Jobsite Inspection Checklist . . . . . . . . . . 13 Start-Up Checklist and Log . . . . . . . . . . . .93 Jobsite Storage . . . . . . . . . . . . . . . . . . . . 13 Operating Pressures . . . . . . . . . . . . . . . . .93 Unit Dimensions and Weights . . . . . . . . . . . 14 Water Pressure Drop . . . . . . . . . . . . . . . .115 GEH and EXH Clearance Dimensions . . . 14 Water Volume . . . . . . . . . . . . . . . . . . . . . .117 GEV ½ to 5 tons and EXV ½ to 6 tons clearance dimensions . . . . . . . . . . . . . . . . . . . 15 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . .118 Weight Distribution for Hanging the GEH and EXH Model . . . . . . . . . . . . . . . . . . . . . . . . 55 Condensate Trap . . . . . . . . . . . . . . . . . . .118 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 General Installation Checks . . . . . . . . . . . 56 Main Electrical . . . . . . . . . . . . . . . . . . . . . 56 Supply-Air Ductwork . . . . . . . . . . . . . . . . 57 Return-Air Ductwork . . . . . . . . . . . . . . . . . 57 Hole Plug Installation . . . . . . . . . . . . . . . . .64 Waterside Economizer Installation . . . . . .65 Preventive Maintenance . . . . . . . . . . . . .118 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . .119 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . .121 Warranty Information . . . . . . . . . . . . . . . . . . .131 Standard Warranty . . . . . . . . . . . . . . . . . .131 Extended Warranty . . . . . . . . . . . . . . . . .131 Ducted Panel . . . . . . . . . . . . . . . . . . . . . . . 57 Ducted Filter Rack . . . . . . . . . . . . . . . . . . . 58 Dual Filtration (GEH ½-5 ton and EXH ½-6 ton) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Sound Attenuation Pad . . . . . . . . . . . . . . 59 Hanging the Horizontal Unit . . . . . . . . . . 59 Condensate Drain Connection . . . . . . . . . 59 4 WSHP-SVX01N-EN Model Number Description ½ to 5 Ton G E H E 0 0 6 1 1 * 0 1 B 0 B R D 0 1 0 0 0 0 1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26-36 Digits 1-3 — Unit Configuration GEH = Standard Efficiency Horizontal GEV = Standard Efficiency Vertical Digit 16 — Return-Air Arrangement Digit 4 — Development Sequence L = Left Return-Air Arrangement R = Right Return-Air Arrangement E = R-410A Digit 17 — Control Types Digits 5-7 — Nominal Capacity 0 = Basic 24V Controls D = Deluxe 24V Controls B =Tracer ZN524 Controls F = UC400 G = UC400 w/ Wireless Comm 006 = ½Ton 009 = ¾Ton 012 = 1Ton 015 = 1¼Ton 018 = 1½Ton 024 = 2Ton 030 = 2½Ton 036 = 3Ton 042 = 3½Ton 048 = 4Ton 060= 5Ton 0 = Wall Mounted Location Digit 8 — Voltage (Volts/Hz/ Phase) 0 = 115/60/1 1 = 208/60/1 2 = 230/60/1 3 = 208/60/3 4 = 460/60/3 Digit 18 — Tstat/Sensor Location 5 = 575/60/3 6 = 220-240/50/1 7 = 265/60/1 8 = 230/60/3 9 = 380-415/50/3 Digit 9 — Heat Exchanger 1 = Copper-Water Coil 2 = Cupro-Nickel Water Coil 7 = Insulated Copper-Water Coil 8 = Insulated Cupro-Nickel Water Coil Digit 10 — Current Design Sequence Digit 11 — Refrigeration Circuit Digit 19 — Fault Sensors 1 = Condensate Overflow Sensor 3 = Condensate Overflow and Filter MaintenanceTimer 6 = Condensate Overflow and Fan Status J = Fan Status, Filter MaintenanceTimer and Condensate Overflow Sensor Digit 20 — Temperature Sensor 0 = None 1 = Entering Water Sensor Digit 21 — Open Digit 22 — Electric Heat 0 = No Electric Heat 1 = Internal Boilerless Electric Heat 4 = External Boilerless Electric Heat Digit 23 — Open 0 = Heating and Cooling Circuit 2 = Heating and Cooling Circuit with Hot Gas Reheat 3 = Heating and Cooling Circuit with Waterside Economizer Digit 24 — Filter Type Digit 12 — Blower Configuration Digit 25 — Acoustic Arrangement 1 = Standard Blower Motor 2 = High Static Blower Motor Digit 13 — Freeze Protection A= 20°F Freezestat (extended range geothermal) B= 35°F Freezestat Digit 14 —Open Digit = 0 1 = 1"Throwaway Filter 2 = 2"Throwaway Filter 4 = MERV 8 5 = MERV 13 0 = Enhanced Sound Attenuation 1 = Deluxe Sound Attenuation Digits 26-36 — Does Not Apply to GEH or GEV 00000000000 = Digits 26-36 are not applicable to the GEH or GEV products Digit 15 — Supply-Air Arrangement B = Back Supply-Air Arrangement F = Front Supply-Air Arrangement L = Left Supply-Air Arrangement R = Right Supply-Air Arrangement T =Top Supply-Air Arrangement WSHP-SVX01N-EN 5 Model Number Description 6 to 25 Ton G E H E 0 7 2 1 1 * 0 A 0 0 A B D 0 0 0 0 0 0 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25-36 Digits 1-3 - Unit Configuration Digit 13 - Freeze Protection GEH = High Efficiency Horizontal GEV = High Efficiency Vertical A = 20°F Freezestat B = 35°F Freezestat Digit 4 - Development Sequence Digit 14 - Open Digit = 0 E = R-410A Digits 5-7 - Nominal Capacity Digit 15 - Supply-Air Arrangement 072 = 6Ton 090 = 7½Ton 120 = 10Ton 150 = 12½Ton B = Back Supply-Air Arrangement F = Front Supply-Air Arrangement L = Left Supply-Air Arrangement R = Right Supply-Air Arrangement T =Top Supply-Air Arrangement 180 = 15Ton 240 = 20Ton 300 = 25Ton Digit 8 - Voltage (Volts/Hz/ Phase) 1 = 208/60/1 2 = 230/60/1 3 = 208/60/3 4 = 460/60/3 5 = 575/60/3 6 = 220-240/50/1 7 = 265/60/1 8 = 230/60/3 9 = 380-415/50/3 B = Back Return-Air Arrangement F = Front Return-Air Arrangement L = Left Return-Air Arrangement R = Right Return-Air Arrangement Digit 17 - Control Types D = Deluxe 24V Controls B = Tracer ZN524 Controls F = UC400 G = UC400 w/ Wireless Comm Digit 18 - Open 1 = Copper-Water Coil 2 = Cupro-Nickel Water Coil 7 = Insulated Copper-Water Coil 8 = Insulated Cupro-Nickel Water Coil 0 = Wall Mounted Location Digit 19 - Fault Sensors 0 = Heating and Cooling Circuit 2 = Heating and Cooling Circuit with Hot Gas Reheat 3 = Heating and Cooling Circuit with Waterside Economizer 4 = Heating and Cooling Circuit with HGR and WSE 0 = No Fault Sensor 1 = Condensate Overflow Sensor 2 = Filter MaintenanceTimer 3 = Condensate Overflow and Filter MaintenanceTimer 4 = Fan Status Sensor 6 = Condensate Overflow and Fan Status H = Fan Status and Filter MaintenanceTimer J = Fan Status, Filter Maintenance Timer and Condensate Overflow Sensor Digit 12 - Blower Configuration Digit 20 - Open A = Drive Package A (GEH/GEV) B = Drive Package B (GEH/GEV) C = Drive Package C (GEH/GEV) D = Drive Package D (GEH/GEV) E = Drive Package E (GEH/GEV) F = Drive Package F (GEH/GEV) G = Drive Package G (GEH/GEV) H = Drive Package H (GEH/GEV) J = Drive Package J (GEH/GEV) 1 = 2 Speed Drive Package A (GEH/GEV) 2 = 2 Speed Drive Package B (GEH/GEV) 3 = 2 Speed Drive Package C (GEH/GEV) 4 = 2 Speed Drive Package D (GEH/GEV) 5 = 2 Speed Drive Package E (GEH/GEV) 6 = 2 Speed Drive Package F (GEH/GEV) 7 = 2 Speed Drive Package G (GEH/GEV) 8 = 2 Speed Drive Package H (GEH/GEV) 9= 2 Speed Drive Package J (GEH/GEV) 0 = No AdditionalTemperature Sensor Digit 11 - Refrigeration Circuit 6 00000000000 = Digits 25-36 are not applicable to the GEH or GEV products Digit 16 - Return-Air Arrangement Digit 9 - Heat Exchanger Digit 10 - Current Design Sequence Digit 25-36 - Does Not Apply to GEH or GEV Digit 21 - Open Digit 22 - Electric Heat 0 = No Electric Heat 4 = External Boilerless Electric Heat 5 = External Supplemental Electric Heat Digit 23 - Open Digit 24 - Filter Type 1 = 1 in.Throwaway Filter 2 = 2 in.Throwaway Filter WSHP-SVX01N-EN Model Number Description ½ to 6 Ton E X H F 0 0 6 1 1 * 0 3 B 0 B R D 0 1 0 0 0 0 1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26-36 Digits 1-3 — Unit Configuration EXH = High Efficiency Horizontal EXV = High Efficiency Vertical Digit 16 — Return-Air Arrangement Digit 4 — Development Sequence L = Left Return-Air Arrangement R = Right Return-Air Arrangement F Digit 17 — Control Types Digits 5-7 — Nominal Capacity 006 - 1/2 ton 009 - 3/4 ton 012 - 1 ton 015 - 1 ¼ ton 018 = 1½Ton 024 = 2Ton 030 = 2½Ton 036 = 3Ton 042 = 3½Ton 048 = 4Ton 060= 5Ton 070= 6Ton Digit 8 — Voltage (Volts/Hz/ Phase) 1 = 208/60/1 2 = 230/60/1 3 = 208/60/3 4 = 460/60/3 7 = 265/60/1 8 = 230/60/3 D = Deluxe 24V Controls B = Tracer™ ZN524 Controls F = UC400 G = UC400 w/ Wireless Comm Digit 18 — Tstat/Sensor Location 0 = Wall Mounted Location Digit 19 — Fault Sensors 1 = Condensate Overflow Sensor 3 = Condensate Overflow and Filter MaintenanceTimer 6 = Condensate Overflow and Fan Status J = Fan Status, Filter MaintenanceTimer and Condensate Overflow Sensor Digit 9 — Heat Exchanger Digit 20 — Temperature Sensor 1 = Copper-Water Coil 2 = Cupro-Nickel Water Coil 7 = Insulated Copper Water Coil/Suction Line 8 = Insulated Cupro-Nickel Water Coil/Suction Line 0 = No AdditionalTemperature Sensor 1 = Entering Water Sensor Digit 10 — Current Design Sequence Digit 11 — Refrigeration Circuit Digit 21 — Open Digit Digit 22 — Electric Heat 0 = No Electric Heat 1 = Internal Boilerless Electric Heat 4 = External Boilerless Electric Heat Digit 23 — Open Digit 0 = Heating and Cooling Circuit 2 = Heating and Cooling Circuit with Hot Gas Reheat 3 = Heating and Cooling Circuit with Waterside Economizer Digit 24 — Filter Type Digit 12 — Blower Configuration Digit 25 — Acoustic Arrangement 3 = ECM Motor Digit 13 - Freeze Protection A = 20°F freezestat B = 35°F freezestat Digit 14 — Open Digit = 0 Digit 15 — Supply-Air Arrangement 1= 2= 4= 5= 1"Throwaway Filter 2"Throwaway Filter MERV 8 MERV13 0 = Enhanced Sound Attenuation 1 = Deluxe Sound Attenuation Digits 26-36 — Does not Apply to EXH or EXV 00000000000 Digits 26-36 are not applicable to the EXH or EXV products B = Back Supply-Air Arrangement L = Left Supply-Air Arrangement R = Right Supply-Air Arrangement T =Top Supply-Air Arrangement WSHP-SVX01N-EN 7 Overview of Manual Note: One copy of this document ships with each unit and is customer property. It must be retained by the unit’s maintenance personnel. This booklet describes proper installation, operation, and maintenance procedures for HVAC systems. By carefully reviewing the information within this manual and following the instructions, the risk of improper operation and/or component damage will be minimized. Service and maintenance work should be performed by a qualified technician and all electrical service and maintenance work should be performed by a qualified licensed electrician. Unit Nameplate Compressor Nameplate The nameplate for the compressors are located on the compressor shell. Model Number Description All products are identified by a multiple-character model number that precisely identifies a particular type of unit. Its use will enable the owner/operator, installing contractors, and service engineers to define the operation, specific components, and other options for any specific unit. When ordering replacement parts or requesting service, be sure to refer to the specific model number and serial number printed on the unit nameplate. The unit nameplate is located on the outside of the control box access panel at the front of the unit. It includes the unit model number, serial number, electrical characteristics, refrigerant charge, and other pertinent unit data. 8 WSHP-SVX01N-EN General Information Unit Description Basic 24V Controls Before shipment, each unit is leak tested, dehydrated, charged with refrigerant and run tested for proper control operation. Safety devices for equipment containing the basic 24V control option include a low-pressure switch to prevent compressor operation during low temperature or low suction activity.The switch is set to activate at refrigerant pressure of 40 psig to fit most applications. Air-to-Refrigerant Coil The air-to-refrigerant coil is aluminum fin, mechanically bonded to the copper tubing. Water-to-Refrigerant Coil The water-to-refrigerant coil is a copper or cupro-nickel (option) and steel tube (tube-within-a-tube) design, leak tested to assure there is no cross leakage between the water tube (copper/cupro-nickel) and refrigerant gas (steel tube). Table 1. High/Low pressure switch Trip Recover Unit LP 40 +/-4 56 +/-4 psig HP 650 +/-10 550 +/-10 psig A high pressure switch prevents compressor operation during high or excessive discharge pressures exceeding 650 psig. The lockout relay will disable the compressor on a high or low pressure condition. For units that contain a condensate overflow switch option, a condensate overflow condition will also disable the compressor through the lockout relay.The relay may be reset at the thermostat, or by cycling power to the unit. General alarm is accomplished through the lockout relay. This feature will drive dry contacts only, and cannot be used to drive field installed control inputs.Trane provides a 3½-minute time delay for compressor control. Deluxe 24V Controls (option) Controls Basic 24V control is available for the GEH/V ½ -5 ton models and the Deluxe 24V control option is available for all unit sizes.Tracer™ ZN524, LonTalk® certified control option is available for all unit sizes. UC400 and UC400 with wireless comm BACnet is available in all unit sizes. All power wiring to the equipment is made at the unit contactor for ½- 5 ton, 1-phase units. For 3-phase units all power wiring to the equipment is made to the contactor or power block. For EXH/V070 units all power wiring to the equipment is made to the power block. For the GEH/V 6-25 tons units all power wiring is made to the high voltage terminal block. All low-voltage wiring is made at the unit’s low voltage terminal board. EXH and EXV 460V units require a neutral wire. System Input Devices and Functions A thermostat, zone sensor, or building automation system is required to operate the water-source heat pump.The flexibility of having several mode capabilities depends upon the type of sensor and/or remote panel selected. Troubleshooting and connection diagrams for the 24V control systems may be located in the back of this manual. All digital control troubleshooting tips and connection diagrams are located in WSHP-PRB002-EN (ZN524). Units containing the Deluxe 24V control design will incorporate a microprocessor-based control board.The Trane® microprocessor board is factory wired to a terminal strip to provide all necessary terminals for field connection.The deluxe board is equipped with a random start relay, anti-short cycle timer, brown out protection, compressor disable, condensate overflow, unit safety control, diagnostics, and a generic relay (which may be available for field use). See Table 65, p. 119 for diagnostic information and Figure 59, p. 62 and Figure 60, p. 63 for thermostat connections. Tracer™ UC400 TheTracer™ UC400 is a BTL Listed BACnet® controller that can operate stand- alone or within a Building Automations system such asTracer™ SC. Tracer ZN524 Controls (option) The digital ZN524 controller is designed to support the ½ to 25 ton water-source heat pumps in either a standalone, peer-to-peer with aTracer Loop Controller, or as a full building automation (open protocol) system. For installation, operation and diagnostics see WSHPPRB002-EN (ZN524). Pump Module (field installed accessory) The pump module shall consist of either a single or dual 1/ 6 HP bronze pump and a brass three-way shut-off valve. Cast iron pumps are also acceptable.The pump module kits shall contain the necessary components for the installation, operation and maintenance of the water circuit of a closed-loop distributed pumping application. WSHP-SVX01N-EN 9 General Information Waterside Economizer (Option) Hot Gas Reheat (option) Instructions for mechanical connection of the waterside economizer to the water-source heat pump may be found in the dimensional section of this manual. With the reheat option, the return-air from the space is conditioned by the air-to-refrigerant coil, then reheated by the reheat coil to control not only the space temperature, but to also reduce the relative humidity of the space.When operating in the reheat mode (meaning the sensible temperature has been met in the space), the humidistat signals the reheat relay coil to energize, allowing the high pressure refrigerant gas to flow from the compressor through the reheat valve, into the reversing valve, or reheat coil. The waterside economizer is designed to begin economizing mode when water temperatures fall below the field adjustable temperature of 25, 35, 45, 55 or 60°F (for the Deluxe control option), or below the programmed set-point (for the ZN524 control option). When the temperature is less than the setpoint, fluid will flow into the economizing coil, while simultaneously halting mechanical operation of the compressor. Mechanical cooling will continue on a call for a second stage from the thermostat or system control. Entering water temperature sensor is factory provided for field installation on the entering water side of the coil. Boilerless Control/Electric Heat (Option) Systems that do not contain a boiler may contain a boilerless control with electric heat.Trane® offers both a factory mounted electric heat option, and a field mounted duct heater option. If the ½-5 ton GEH, GEV and EXH/V070 unit incorporates the factory mounted option, the unit will ship from the factory with an internally mounted nichrome open wire heating element, designed to start-up electric heat as the systems primary heat in the event entering water temperature falls below 55°F. Once the entering water temperature rises above 60°F, the boilerless controller returns the unit to normal compressor heating operation, and locks out the electric heater. For units comprised of the field installed duct heater option, the unit will ship from the factory with controls available to interface with the field provided electric heat selection. Note: For geothermal applications, the boilerless controller has an adjustable setting of 25, 35, 45, 55, and 60 degrees. Supplemental or Boilerless Electric Heat (option) The GEH/V 6-25 ton models which contain boilerless control electric heat or supplemental electric heat will contain the controls interface ONLY for field provided electric heat selection.The heater for this model shall be external to the equipment by the contractor for ease of installation. All power connections for the electric heater will be completely separate from the unit for field supplied electric heat. A switching relay has been provided for the reheat application to adjust the blower motor from normal operation to low speed when the hot gas reheat is energized (for ½ -5 ton and EXH/V070 equipment only). Note: A high static blower motor is required to support the hot gas reheat option for the GEH/V ½ -5 ton. Note: Units containing the hot gas reheat option should not be used as a make-up air unit. 2 Speed Blower Motor (option) The 6-25 ton GEH/V models have indoor blowers that are available with 2 speed motors, selectable in the model number (Digit 12, drive packages one to nine). High speed airflow matches the single speed motor airflow, referenced in the Fan Performance tables. Low fan speed airflow is approximately 50% of high fan speed airflow. The 6-25 ton GEH/V two-speed blower motors are available with the following options: Deluxe 24V or UC400 controls, Heat Pump (HP) or HP w/Hot Gas Reheat or HP w/ Waterside Economizer. Not available with Boilerless or Supplemental Electric Heat. Table 2. 6 to 25 ton GEH/V fan speed for two-speed drive packages one to nine Compresso Compresso r1 r2 Fan Speed RV State Fan Heat OFF OFF OFF OFF Heat ON OFF OFF HIGH Heat ON ON OFF HIGH Heat ON ON ON HIGH Cool OFF OFF OFF OFF Cool ON OFF OFF LOW Cool ON ON OFF LOW Cool ON ON ON HIGH Note: When the unit has boilerless control, the electric heat is not used as supplemental electric heat, but as a primary heat. 10 WSHP-SVX01N-EN General Information Table 3. Refrigerant charge Model (60 Hz) Heat Pump (oz)/(Kg) Heat Pump w/HGR (oz)/(Kg) Circuit 1 Circuit 2 Circuit 1 GEHE006 25.3 / .717 ----- 26.8 / .760 Circuit 2 ----- GEHE009 26.0 / .737 ----- 27.5 / .780 ----- GEHE012 28.5 / .808 ----- 30.5 / .865 ----- GEHE015 29.0 / .822 ----- 30.5 / .865 ----- GEHE018 36.5 / 1.035 ----- 39.5 / 1.120 ----- GEHE024 39.0 / 1.106 ----- 42.0 / 1.191 ----- GEHE030 44.0 / 1.247 ----- 46.5 / 1.318 ----- GEHE036 50.0 / 1.417 ----- 53.5 / 1.517 ----- GEHE042 57.0 / 1.616 ----- 60.5 / 1.715 ----- GEHE048 61.0 / 1.729 ----- 65.5 / 1.857 ----- GEHE060 73.0 / 2.070 ----- 77.5 / 2.197 ----- GEVE006 25.7 / .789 ----- 27.2 / .771 ----- GEVE009 26.5 / .751 ----- 28.0 / .794 ----- GEVE012 29.5 / .836 ----- 31.5 / .893 ----- GEVE015 27.5 / .780 ----- 29.5 / .836 ----- GEVE018 37.0 / 1.049 ----- 40.0 / 1/134 ----- GEVE024 39.0 / 1.106 ----- 41.5 / 1.177 ----- GEVE030 44.5 / 1.262 ----- 47.0 / 1.332 ----- GEVE036 51.0 / 1.446 ----- 54.5 / 1.545 ----- GEVE042 54.0 / 1.531 ----- 57.5 / 1.630 ----- GEVE048 61.0 / 1.729 ----- 66.0 / 1.871 ----- GEVE060 74.0 / 2.098 ----- 79.5 / 2.254 ----- GEHE072 55 / 1.559 55 / 1.559 59 / 1.673 55 / 1.559 GEHE090 64 / 1.814 54 / 1.531 68 / 1.928 54 / 1.531 GEHE120 86 / 2.438 86 / 2.438 90 / 2.551 86 / 2.438 GEHE150 136 / 3.856 136 / 3.856 144 / 4.082 136 / 3.856 GEHE180 126 / 3.572 126 / 3.572 134 / 3.799 126 / 3.572 GEVE072 58 / 1.644 58 / 1.644 62 / 1.758 58 / 1.644 GEVE090 83 / 2.353 75 / 2.126 87 / 2.466 75 / 2.126 GEVE120 88 / 2.495 88 / 2.495 92 / 2.608 88 / 2.495 GEVE150 122 / 3.459 122 / 3.459 130 / 3.685 122 / 3.459 GEVE180 128 / 3.629 128 / 3.629 136 / 3.856 128 / 3.629 GEVE240 284 / 8.051 284 / 8.051 292 / 8.278 284 / 8.051 GEVE300 260 / 7.371 260 / 7.371 267 / 7.569 260 / 7.371 EXHF006 25.3 / 0.717 ----- 26.8 / 0.760 ----- EXHF009 26.0 / 0.737 ----- 27.5 / 0.780 ----- EXHF012 28.5 / 0.808 ----- 30.5 / 0.865 ----- EXHF015 29.0 / 0.822 ----- 30.5 / 0.865 ----- EXHF018 45.0 / 1.276 ----- 48.0 / 1.361 ----- EXHF024 50.5 / 1.432 ----- 53.0 / 1.503 ----- EXHF030 53.0 / 1.503 ----- 56.0 / 1.588 ----- EXHF036 70.0 / 1.984 ----- 73.0 / 2.070 ----- EXHF042 81.0 / 2.296 ----- 85.5 / 2.424 ----- EXHF048 83.0 / 2.353 ----- 87.5 / 2.481 ----- continued on next page WSHP-SVX01N-EN 11 General Information Table 3. Refrigerant charge (continued) Model (60 Hz) 12 Heat Pump (oz)/(Kg) Heat Pump w/HGR (oz)/(Kg) EXHF060 114.0 / 3.232 ----- 118.5 / 3.359 ----- EXHF070 122.0 / 3.459 ----- 127.0 / 3.600 ----- EXVF006 25.7 / 0.729 ----- 27.2 / 0.771 ----- EXVF009 26.5 / 0.751 ----- 28.0 / 0.794 ----- EXVF012 29.5 / 0.836 ----- 31.5 / 0.893 ----- EXVF015 30.0 / 0.850 ----- 32.0 / 0.907 ----- EXVF018 45.0 / 1.276 ----- 48.0 / 1.361 ----- EXVF024 52.0 / 1.474 ----- 54.5 / 1.545 ----- EXVF030 53.0 / 1.503 ----- 56.0 / 1.588 ----- EXVF036 70.0 / 1.984 ----- 73.0 / 2.070 ----- EXVF042 81.0 / 2.296 ----- 86.0 / 2.438 ----- EXVF048 83.0 / 2.353 ----- 88.5 / 2.509 ----- EXVF060 114.0 / 3.232 ----- 119.5 / 3.388 ----- EXVF070 122.0 / 3.459 ----- 128.0 / 3.629 ----- WSHP-SVX01N-EN Pre-Installation Jobsite Storage WARNING Fiberglass Wool! Product contains fiberglass wool. Disturbing the insulation in this product during installation, maintenance or repair will expose you to airborne particles of glass wool fibers and ceramic fibers known to the state of California to cause cancer through inhalation. Glass wool fibers may also cause respiratory, skin or eye irritation. Unit Inspection Checklist • Unpack all components of the kit. • Check carefully for any shipping damage. If any damage is found it must be reported immediately and a claim made against the transportation company. Important: Equipment is shipped FOB (Free on Board) at the manufacturer.Therefore, freight claims for damages against the carrier must be initiated by the receiver. • Visually inspect the components for shipping damage as soon as possible after delivery, before it is stored. Concealed damage must be reported within 15 days. • If concealed damage is discovered, stop unpacking the shipment. • Do not remove damaged material from the receiving location.Take photos of the damage, if possible.The owner must provide reasonable evidence that the damage did not occur after delivery. • Notify the carrier’s terminal of damage immediately by phone and by mail. Request an immediate joint inspection of the damage by the carrier and the consignee. • WARNING Microbial Growth! Wet interior unit insulation can become an amplification site for microbial growth (mold), which may cause odors and serious health related indoor air quality problems. If there is evidence of microbial growth (mold) on the interior insulation, remove or replace the insulation prior to operating the system. Failure to remove microbial growth could result in serious health problems. This unit is intended for indoor use only.To protect the unit from damage due to the elements, and to prevent possible IAQ contaminant sources from growing, the unit should be stored indoors. If indoor storage is not possible, the following provisions for outdoor storage must be met: • Place the unit(s) on a dry surface or raise above the ground to assure adequate air circulation beneath the unit. • Cover the unit(s) with a water proof tarp to protect them from the elements. • Make provisions for continuous venting of the covered units to prevent moisture from standing on the unit(s) surfaces. Wet interior unit insulation can become an amplification site for microbial growth (mold) which has been determined to be a cause of odors and serious health related indoor air quality problems. • Store units in the normal UP orientation to maintain oil in the compressor. • Horizontal units may be stacked no more than three units high. Do not stack the vertical unit configurations. Do not attempt to repair any damaged parts until the parts are inspected by the carrier’s representative. Jobsite Inspection Checklist Always perform the following checks before accepting a unit: • Verify that the nameplate data matches the data on the sales order and bill of lading (including electrical data). • Verify that the power supply complies with the unit nameplate specifications. • Visually inspect the exterior of the unit, for signs of shipping damage. Do not sign the bill of lading accepting the unit(s) until inspection has been completed. Check for damage promptly after the unit(s) are unloaded. Once the bill of lading is signed at the jobsite, the unit(s) are now the property of the SOLDTO party and future freight claims MAY NOT be accepted by the freight company. WSHP-SVX01N-EN 13 Unit Dimensions and Weights GEH and EXH Clearance Dimensions Access to the unit for service purposes should be provided at installation. All ½-5 tons and EXH070 configurations (see Figure 1, p. 14) require an 18 in. (457 mm) surround clearance from other mechanical and electrical equipment (where shown) to enable panel removal from the unit for service/maintenance ability. NEC requires 36 in. clearance on the control panel side of the unit. Some local codes require a greater service clearance than listed below. Check all code requirements prior to unit installations. Equipment containing a same-side supply/return combination requires a 3 in. (229 mm) limitation on one side. Access to theTXV may not be possible with this 3 in. (229 mm) clearance.This configuration is typically applied in a corridor installation, where space limitations force the left or right side of the unit against a wall. Figure 1. GEH ½ to 5 tons and EXH ½ to 6 tons clearance 18" (457) (3-SIDES) 18" (457) (3-SIDES) 18" (457) (3-SIDES) LEFT RETURN RIGHT SUPPLY LEFT RETURN BACK SUPPLY LEFT RETURN LEFT SUPPLY 3" (76) UNIT FRONT RIGHT RETURN BACK SUPPLY 36" (914) 18" (457) (3-SIDES) 36" (914) UNIT FRONT 36" (914) UNIT FRONT 18" (457) (3-SIDES) 18" (457) (3-SIDES) RIGHT RETURN LEFT SUPPLY RIGHT RETURN RIGHT SUPPLY Figure 2. UNIT FRONT 36" (914) Service clearance dimensions for the GEH 6-15 tons horizontal (see Figure 2, p. 14) includes a two side access appropriate for control and blower motor/wheel access. Some local codes require a greater service clearance than listed below. Check all code requirements prior to unit installations. GEH 6-15 tons clearance CONTROL BOX 36" (914) SERVICE CLEARANCE 20" (508) SERVICE CLEARANCE 14 UNIT FRONT 36" (914) UNIT FRONT 36" (914) 3" (76) TOP VIEW BLOWER ACCESS PANEL WSHP-SVX01N-EN Unit Dimensions and Weights GEV ½ to 5 tons and EXV ½ to 6 tons clearance dimensions Access to the unit for service purposes should be provided at installation. A 24 in. surround clearance (see Figure 3, p. 15) from other mechanical and electrical equipment (where shown) is recommended for all configurations. This will enable panel removal from the unit for service/ maintenance. Some local codes require a greater service clearance than listed below. Check all code requirements prior to unit installations. Units in a free return application will require more than a 12 in. minimum clearance to provide proper air flow to the units air-to-refrigerant coil. Pictured in Figure 3, p. 15 minimum 1” clearance on return side with properly attached duct work. A 36 in. service clearance is required for all configurations at the unit front. It is recommended that 20 in of service clearance for the sides (see Figure 4, p. 15) from other mechanical and electrical equipment (where shown).The unit may be serviced through the front access panel or remaining open sides. Some local codes require a greater service clearance than listed below. Check all code requirements prior to unit installations. Figure 4. GEV 6–10 tons clearance FRONT RETURN TOP SUPPLY GEV ½-5 tons and EXV ½-6 tons clearance dimensions 1" (25.4) Figure 3. GEV 6–10 Tons Clearance Dimensions ACCESS PANEL FOR SHEAVES AND BELTS 20" (508) SERVICE CLEARANCE 36" (914) SERVICE CLEARANCE GEV 12½–25 Tons Clearance Dimensions 24" (610) Figure 5, p. 15 outlines service clearances. A 36 in. service clearance is required for all configurations at the unit front. A 24 in. service clearance (see Figure 3, p. 15) from other mechanical and electrical equipment (where shown) is recommended for all configurations.The unit may be serviced through the front access panel. Some local codes require a greater service clearance than listed below. Check all code requirements prior to unit installations. UNIT FRONT 36" (914) RIGHT RETURN TOP/BACK SUPPLY 1" (25.4) Figure 5. GEV 12½–25 tons clearance 1" (25.4) 18" (457) FRONT RETURN-AIR BACK SUPPLY-AIR CONTROL BOX NEC REQ. MIN. 36" (914) C.B. TO WALL CLEARANCE 1" (25.4) WSHP-SVX01N-EN 36" (914) UNIT FRONT UNIT FRONT 16" (406) TO FILTER FRAME FOR RETURN-AIR MIN. SERVICE CLEARANCE FOR EITHER LEFT OR RIGHT SIDE IS 22" (559). FOR FAN SHAFT REMOVAL, A 22" (559) CLEARANCE MUST BE PROVIDED ON EITHER THE LEFT OR RIGHT SIDE. 24" (610) LEFT RETURN TOP/BACK SUPPLY 15 Unit Dimensions and Weights Figure 6. Left return/left supply (GEH/EXH) P B TOP R S N A FXG OPENING H Q PANEL HI VOLT L (W.O.) WCI mounting location LO VOLT 1/2" (13) 3/4" (19) NPTI J H BACK LEFT SIDE D M (W.I.) 1" (25.4) K DRAIN 7" (178) ACCESS FRONT 1 3/8" (35) C REFRIG AND CONTROL ACCESS 6 3/4" (171) 1" (25.4) BLOWER E 14" (356") RIGHT SIDE Table 4. GEH Unit Left return/left supply (GEH/EXH) A B Hi-048, 060 40 (1016) 40 (1016) 46 (1168) 46 (1168) 50 (1270) 58 (1473) 58 (1473) 20 (508) 20 (508) 23 (584) 23 (584) 25 (635) 33 (838) 33 (838) EXH Unit A B 40 (1016) 40 (1016) 46 (1168) 50 (1270) 58 (1473) 58 (1473) 20 (508) 20 (508) 23 (584) 25 (635) 33 (838) 39 (991) 006, 009 012, 015 018 024, 030 036, 042 Std-048 006-009 012-015 018-024 030-036 042-070 070 C D(a) E FxG 15 20 15 6-7/8 x 8 (381) (508) (381) (175) x (203) 15 20 15 6-7/8 x 9-7/8 (381) (508) (381) (175) x (251) 18 23 18 8-1/4 x 9-3/4 (457) (584) (457) (210) x (248) 18 23 18 8-1/4 x 11-3/8 (457) (584) (457) (210) x (289) 19 25 20 10-1/2 x 13-1/2 (483) (635) (508) (267) x (343) 21 29-1/2 23-1/2 13-1/8 x 11-3/8 (533) (597) (749) (333) x (289) 21 29-1/2 23-1/2 13-7/8 x 13-7/8 (533) (597) (749) (352) x (352) C D(a) E FxG 15 20 15 6-7/8 x 8 (381) (508) (381) (175) x (203) 15 20 15 8-1/4 x 9-3/4 (381) (508) (381) (210) x (248) 18 23 18 8-1/4 x 11-3/8 (457) (584) (457) (210) x (289) 19 25 20 10-1/2 x 13-1/2 (483) (635) (508) (267) x (343) 21 29-1/2 23-1/2 13-1/8 x 11-3/8 (533) (597) (749) (333) x (289) 21 29-1/2 23-1/2 13-7/8 x 13-7/8 (533) (597) (749) (352) x (352) H J K 11-1/2 (292) 11-1/2 (292) 13-1/2 (343) 13-1/2 (343) 17 (432) 18 (457) 18 (457) 4-1/2 (114) 4-1/4 (108) 4-3/4 (121) 4-3/4 (121) 4 (102) 5-1/4 (133) 5-1/4 (133) 1-3/4 (45) 3/4 (19) 1-3/8 (35) 1-3/8 (35) 1 (25) 1-1/2 (38) 1-1/2 (38) H J K 11-1/2 (292) 11-1/2 (292) 13-1/2 (343) 17 (432) 18 (457) 18 (457) 4-1/4 (108) 4-1/4 (108) 4-3/4 (121) 4 (102) 5-1/4 (133) 5-1/4 (133) 1-3/4 (45) 3/4 (19) 1-3/8 (35) 1 (25) 1-1/2 (38) 1-1/2 (38) L M NPTI NPTI 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 1 (25) 1 (25) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 1 (25) 1 (25) L M NPTI NPTI 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25) 1 (25) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25) 1 (25) N P Q R(b) S 38-3/4 (984) 38-3/4 (984) 44-3/4 (1137) 44-3/4 (1137) 48-3/4 (1238) 56-3/4 (1441) 56-3/4 (1441) 18-3/4 (476) 18-3/4 (476) 21-3/4 (552) 21-3/4 (552) 23-3/4 (603) 31-3/4 (806) 31-3/4 (806) 13-5/8 (346) 13-5/8 (346) 16-5/8 (422) 16-5/8 (422) 17-5/8 (448) 19-5/8 (498) 19-5/8 (498) 18-1/2 (470) 18-1/2 (470) 18-1/2 (470) 18-1/2 (597) 23-1/2 (597) 23-1/2 (597) 23-1/2 (597) 3-1/4 (83) 3-1/4 (83) 4-1/4 (108) 4-1/4 (108) 3-1/4 (83) 5-1/2 (140) 5-1/2 (140) N P Q R(b) S 38-3/4 (984) 38-3/4 (984) 44-3/4 (1137) 48-3/4 (1238) 56-3/4 (1441) 56-3/4 (1441) 18-3/4 (476) 18-3/4 (476) 21-3/4 (552) 23-3/4 (603) 31-3/4 (806) 37-3/4 (959) 13-5/8 (346) 13-5/8 (346) 16-5/8 (422) 17-5/8 (448) 19-5/8 (498) 19-5/8 (498) 18-1/2 (470) 18-1/2 (470) 18-1/2 (470) 23-1/2 (597) 23-1/2 (597) 23-1/2 (597) 3-1/4 (83) 3-1/4 (83) 4-1/4 (108) 3-1/4 (83) 5-1/2 (140) 5-1/2 (140) Notes: 1. All dimensions are in inches followed by millimeters in parenthesis. 2. Access to the unit for service purposes should be provided at installation. Horizontal units require an 18 in. (457 mm) surround clearance from other mechanical and electrical equipment to enable panel removal from the unit for service/maintenance ability. NEC requires 36 in. clearance on the control panel side of the unit. Some local codes require a greater service clearance. Check all code requirements prior to unit installations. Installer is responsible for following all local and NEC code requirements. 3. Equipment containing a same-side supply/return combination requires a 3 in. (229 mm) clearance on one side. Access to the TXV may not be possible with this 3 in. (229 mm) clearance. 4. If hot gas reheat is specified for a size 018, 024, the actual cabinet size increases to an 036 cabinet. 5. When a horizontal model is ordered with the same side return and supply in a ducted application, bottom filter removal is required due to limited access on either side of the filter. (a) Return air opening dimension (b) Filter rack dimension 16 WSHP-SVX01N-EN Unit Dimensions and Weights Figure 7. Left return/back supply (GEH/EXH) P B TOP S R A 1"(25.4) C BLOWER H REFRIG AND CONTROL ACCESS ACCESS Q PANEL L (W.O.) HI VOLT WCI mounting location LO VOLT BACK LEFT SIDE D 1/2" (13) M (W.I.) 1" (25.4) J K H DRAIN 3/4" (19) NPTI 7" (178) OPENING FRONT E 1 3/8" (35) N 6 3/4" (171) FXG 14" (356) RIGHT SIDE Table 5. GEH Unit Left return/back supply (GEH/EXH) A 40 (1016) 40 012, 015 (1016) 46 018 (1168) 46 024, 030 (1168) 50 036, 042 (1270) 58 Std-048 (1473) 58 Hi-048, 060 (1473) 006, 009 EXH Unit 006-009 012-015 018-024 030-036 042-070 070 B 20 (508) 20 (508) 23 (584) 23 (584) 25 (635) 33 (838) 33 (838) A B 40 (1016) 40 (1016) 46 (1168) 50 (1270) 58 (1473) 58 (1473) 20 (508) 20 (508) 23 (584) 25 (635) 33 (838) 39 (991) C D(a) E FxG 15 20 15 6-7/8 x 8 (381) (508) (381) (175) x (203) 15 20 15 6-7/8 x 9-7/8 (381) (508) (381) (175) x (251) 18 23 18 8-1/4 x 9-3/4 (457) (584) (457) (210) x (248) 18 23 18 8-1/4 x 11-3/8 (457) (584) (457) (210) x (289) 19 25 20 10-1/2 x 13-1/2 (483) (635) (508) (267) x (343) 21 29-1/2 23-1/2 13-1/8 x 11-3/8 (533) (597) (749) (333) x (289) 21 29-1/2 23-1/2 13-7/8 x 13-7/8 (533) (597) (749) (352) x (352) C D(a) E FxG 15 20 15 6 -7/8 x 8 (381) (508) (381) (175) x (203) 15 20 15 8-1/4 x 9-3/4 (381) (508) (381) (210) x (248) 18 23 18 8-1/4 x 11-3/8 (457) (584) (457) (210) x (289) 19 25 20 10-1/2 x 13-1/2 (483) (635) (508) (267) x (343) 21 29-1/2 23-1/2 13-1/8 x 11-3/8 (533) (597) (749) (333) x (289) 21 29-1/2 231/2 13-7/8 x 13-7/8 (533) (597) (749) (352) x (352) H J K 11-1/2 (292) 11-1/2 (292) 13-1/2 (343) 13-1/2 (343) 17 (432) 18 (457) 18 (457) 4-1/2 (114) 4-1/4 (108) 4-3/4 (121) 4-3/4 (121) 4 (102) 5-1/4 (133) 5-1/4 (133) 1-3/4 (45) 3/4 (19) 1-3/8 (35) 1-3/8 (35) 1 (25) 1-1/2 (38) 1-1/2 (38) H J K 11-1/2 (292) 11-1/2 (292) 13-1/2 (343) 17 (432) 18 (457) 18 (457) 4-1/2 (114) 4-1/4 (108) 4-3/4 (121) 4 (102) 9-3/4 (248) 9-3/4 (248) 1-3/4 (45) 2-3/4 (70) 3-1/4 (83) 1 (25) 1-1/2 (38) 1-1/2 (38) L M NPTI NPTI 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 1 (25) 1 (25) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 1 (25) 1 (25) L M NPTI NPTI 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25) 1 (25) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25) 1 (25) N P Q R(b) S 38-3/4 (984) 38-3/4 (984) 44-3/4 (1137) 44-3/4 (1137) 48-3/4 (1238) 56-3/4 (1441) 56-3/4 (1441) 18-3/4 (476) 18-3/4 (476) 21-3/4 (552) 21-3/4 (552) 23-3/4 (603) 31-3/4 (806) 31-3/4 (806) 13-5/8 (346) 13-5/8 (346) 16-5/8 (422) 16-5/8 (422) 17-5/8 (448) 19-5/8 (498) 19-5/8 (498) 18-1/2 (470) 18-1/2 (470) 18-1/2 (470) 18-1/2 (597) 23-1/2 (597) 23-1/2 (597) 23-1/2 (597) 3-1/4 (83) 3-1/4 (83) 4-1/4 (108) 4-1/4 (108) 3-1/4 (83) 5-1/2 (140) 5-1/2 (140) N P Q R(b) S 38-3/4 (984) 38-3/4 (984) 44-3/4 (1137) 48-3/4 (1238) 56-3/4 (1441) 56-3/4 (1441) 18-3/4 (476) 18-3/4 (476) 21-3/4 (552) 23-3/4 (603) 31-3/4 (806) 37-3/4 (959) 13-5/8 (346) 13-5/8 (346) 16-5/8 (422) 17-5/8 (448) 19-5/8 (498) 19-5/8 (498) 18-1/2 (470) 18-1/2 (470) 18-1/2 (470) 23-1/2 (597) 23-1/2 (597) 23-1/2 (597) 3-1/4 (83) 3-1/4 (83) 4-1/4 (108) 3-1/4 (83) 5-1/2 (140) 5-1/2 (140) Notes: 1. All dimensions are in inches followed by millimeters in parenthesis. 2. Access to the unit for service purposes should be provided at installation. Horizontal units require an 18 in. (457 mm) surround clearance from other mechanical and electrical equipment to enable panel removal from the unit for service/maintenance ability. NEC requires 36 in. clearance on the control panel side of the unit. Some local codes require a greater service clearance. Check all code requirements prior to unit installations. Installer is responsible for following all local and NEC code requirements. 3. Equipment containing a same-side supply/return combination requires a 3 in. (229 mm) clearance on one side. Access to the TXV may not be possible with this 3 in. (229 mm) clearance. 4. If hot gas reheat is specified for a size 018, 024, the actual cabinet size increases to an 036 cabinet. (a) Return air opening dimension (b) Filter rack dimension WSHP-SVX01N-EN 17 Unit Dimensions and Weights Figure 8. Left return/right supply (GEH/EXH) P B TOP S R N A BLOWER ACCESS PANEL REFRIG AND CONTROL ACCESS Q L (W.O.) HI VOLT 7" (178) 1" (25.4) D 6 3/4" (171) E WCI mounting location 1" (25.4) BACK 1/2" (13) DRAIN 3/4" (19) NPTI LEFT SIDE FXG OPENING C 1 3/8" (35) M (W.I.) LO VOLT FRONT H 14" RIGHT SIDE K H Table 6. Left return/right supply (GEH/EXH) GEH Unit A 40 006, 009 (1016) 40 012, 015 (1016) 46 018 (1168) 46 024, 030 (1168) 50 036, 042 (1270) 58 Std-048 (1473) 58 Hi-048, 060 (1473) EXH Unit 006-009 012-015 018-024 030-036 042-070 070 J B 20 (508) 20 (508) 23 (584) 23 (584) 25 (635) 33 (838) 33 (838) A B 40 (1016) 40 (1016) 46 (1168) 50 (1270) 58 (1473) 58 (1473) 20 (508) 20 (508) 23 (584) 25 (635) 33 (838) 39 (991) C D(a) E FxG 15 20 15 (381) (508) (381) 15 20 15 (381) (508) (381) 18 23 18 (457) (584) (457) 18 23 18 (457) (584) (457) 19 25 20 (483) (635) (508) 21 29-1/2 23-1/2 (533) (597) (749) 21 29-1/2 23-1/2 (533) (597) (749) 6-7/8 x 8 (175) x (203) 6-7/8 x 9-7/8 (175) x (251) 8-1/4 x 9-3/4 (210) x (248) 8-1/4 x 11-3/8 (210) x (289) 10-1/2 x 13-1/2 (267) x (343) 13-1/8 x 11-3/8 (333) x (289) 13-7/8 x 13-7/8 (352) x (352) D(a) FxG C E 15 20 15 6-7/8 x 8 (381) (508) (381) (175) x (203) 15 20 15 8-1/4 x 9-3/4 (381) (508) (381) (210) x (248) 18 23 18 8-1/4 x 11-3/8 (457) (584) (457) (210) x (289) 19 25 20 10-1/2 x 13-1/2 (483) (635) (508) (267) x (343) 21 29-1/2 23-1/2 13-1/8 x 11-3/8 (533) (597) (749) (333) x (289) 21 29-1/2 23-1/2 13-7/8 x 13-7/8 (533) (597) (749) (352) x (352) H J 11-1/2 4-1/2 (292) (114) 11-1/2 4-1/4 (292) (108) 13-1/2 4-3/4 (343) (121) 13-1/2 4-3/4 (343) (121) 17 4 (102) (432) 18 5-1/4 (457) (133) 18 5-1/4 (457) (133) K 1-3/4 (45) 2-3/4 (70) 3-1/4 (83) 3-1/4 (83) 1 (25) 1-1/2 (38) 1-1/2 (38) H J K 11-1/2 (292) 11-1/2 (292) 13-1/2 (343) 17 (432) 18 (457) 18 (457) 4-1/2 (114) 4-1/4 (108) 4-3/4 (121) 4 (102) 5-1/4 (133) 5-1/4 (133) 1-3/4 (45) 2-3/4 (70) 3-1/4 (83) 1 (25) 1-1/2 (38) 1-1/2 (38) L M NPTI NPTI 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 1 (25) 1 (25) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 1 (25) 1 (25) L M NPTI NPTI 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25) 1 (25) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25) 1 (25) N P Q R(b) S 38-3/4 (984) 38-3/4 (984) 44-3/4 (1137) 44-3/4 (1137) 48-3/4 (1238) 56-3/4 (1441) 56-3/4 (1441) 18-3/4 (476) 18-3/4 (476) 21-3/4 (552) 21-3/4 (552) 23-3/4 (603) 31-3/4 (806) 31-3/4 (806) 13-5/8 (346) 13-5/8 (346) 16-5/8 (422) 16-5/8 (422) 17-5/8 (448) 19-5/8 (498) 19-5/8 (498) 18-1/2 (470) 18-1/2 (470) 18-1/2 (470) 18-1/2 (597) 23-1/2 (597) 23-1/2 (597) 23-1/2 (597) 3-1/4 (83) 3-1/4 (83) 4-1/4 (108) 4-1/4 (108) 3-1/4 (83) 5-1/2 (140) 5-1/2 (140) N P Q R(b) S 38-3/4 (984) 38-3/4 (984) 44-3/4 (1137) 48-3/4 (1238) 56-3/4 (1441) 56-3/4 (1441) 18-3/4 (476) 18-3/4 (476) 21-3/4 (552) 23-3/4 (603) 31-3/4 (806) 37-3/4 (959) 13-5/8 (346) 13-5/8 (346) 16-5/8 (422) 17-5/8 (448) 19-5/8 (498) 19-5/8 (498) 18-1/2 (470) 18-1/2 (470) 18-1/2 (470) 23-1/2 (597) 23-1/2 (597) 23-1/2 (597) 3-1/4 (83) 3-1/4 (83) 4-1/4 (108) 3-1/4 (83) 5-1/2 (140) 5-1/2 (140) Notes: 1. All dimensions are in inches followed by millimeters in parenthesis. 2. Access to the unit for service purposes should be provided at installation. Horizontal units require an 18 in. (457 mm) surround clearance from other mechanical and electrical equipment to enable panel removal from the unit for service/maintenance ability. NEC requires 36 in. clearance on the control panel side of the unit. Some local codes require a greater service clearance. Check all code requirements prior to unit installations. Installer is responsible for following all local and NEC code requirements. 3. Equipment containing a same-side supply/return combination requires a 3 in. (229 mm) clearance on one side. Access to the TXV may not be possible with this 3 in. (229 mm) clearance. 4. If hot gas reheat is specified for a size 018, 024, the actual cabinet size increases to an 036 cabinet. (a) Return air opening dimension (b) Filter rack dimension 18 WSHP-SVX01N-EN Unit Dimensions and Weights Figure 9. Right return/left supply (GEH/EXH) S R P B TOP N A 1" (25.4) BLOWER ACCESS PANEL D FXG OPENING H REFRIG AND CONTROL ACCESS 6 3/4" (171) E Q HI VOLT WCI mounting location LEFT SIDE C L (W.O.) FRONT M (W.I.) 7" (178) DRAIN 3/4" (19) NPTI 1/2" (13) J BACK 1"(25.4) K LO VOLT H 14" (356) 1 3/8"(35) RIGHT SIDE Table 7. GEH Unit Right return/left supply (GEH/EXH) B C D(a) 20 (508) 20 (508) 23 (584) 23 (584) 25 (635) 33 (838) 33 (838) 15 (381) 15 (381) 18 (457) 18 (457) 19 (483) 21 (533) 21 (533) 20 (508) 20 (508) 23 (584) 23 (584) 25 (635) 29-1/2 (597) 29-1/2 (597) A B C D(a) 40 (1016) 40 (1016) 46 (1168) 50 (1270) 58 (1473) 58 (1473) 20 (508) 20 (508) 23 (584) 25 (635) 33 (838) 39 (991) 15 (381) 15 (381) 18 (457) 19 (483) 21 (533) 21 (533) 20 (508) 20 (508) 23 (584) 25 (635) 29-1/2 (597) 29-1/2 (597) A 40 006, 009 (1016) 40 012, 015 (1016) 46 018 (1168) 46 024, 030 (1168) 50 036, 042 (1270) 58 Std-048 (1473) 58 Hi-048, 060 (1473) EXH Unit 006-009 012-015 018-024 030-036 042-070 070 E FxG 15 6-7/8 x 8 (381) (175) x (203) 15 6-7/8 x 9-7/8 (381) (175) x (251) 18 8-1/4 x 9-3/4 (457) (210) x (248) 18 8-1/4 x 11-3/8 (457) (210) x (289) 20 10-1/2 x 13-1/2 (508) (267) x (343) 23-1/2 13-1/8 x 11-3/8 (749) (333) x (289) 23-1/2 13-7/8 x 13-7/8 (749) (352) x (352) E FxG 15 6-7/8 x 8 (381) (175) x (203) 15 8-1/4 x 9-3/4 (381) (210) x (248) 18 8-1/4 x 11-3/8 (457) (210) x (289) 20 10-1/2 x 13-1/2 (508) (267) x (343) 23-1/2 13-1/8 x 11-3/8 (749) (333) x (289) 23-1/2 13-7/8 x 13-7/8 (749) (352) x (352) H 11-1/2 (292) 11-1/2 (292) 13-1/2 (343) 13-1/2 (343) 17 (432) 18 (457) 18 (457) J K 4-1/2 1-3/4 (114) (45) 4-1/4 3/4 (19) (108) 4-3/4 1-3/8 (121) (35) 4-3/4 1-3/8 (121) (35) 4 1 (102) (25) 5-1/4 1-1/2 (133) (38) 5-1/4 1-1/2 (133) (38) H J K 11-1/2 (292) 11-1/2 (292) 13-1/2 (343) 17 (432) 18 (457) 18 (457) 4-1/2 (114) 4-1/4 (108) 4-3/4 (121) 4 (102) 5-1/4 (133) 5-1/4 (133) 1-3/4 (45) 3/4 (19) 1-3/8 (35) 1 (25) 1-1/2 (38) 1-1/2 (38) L M NPTI NPTI 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 1 (25) 1 (25) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 1 (25) 1 (25) L M NPTI NPTI 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25) 1 (25) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25) 1 (25) N P Q R(b) S 38-3/4 (984) 38-3/4 (984) 44-3/4 (1137) 44-3/4 (1137) 48-3/4 (1238) 56-3/4 (1441) 56-3/4 (1441) 18-3/4 (476) 18-3/4 (476) 21-3/4 (552) 21-3/4 (552) 23-3/4 (603) 31-3/4 (806) 31-3/4 (806) 13-5/8 (346) 13-5/8 (346) 16-5/8 (422) 16-5/8 (422) 17-5/8 (448) 19-5/8 (498) 19-5/8 (498) 18-1/2 (470) 18-1/2 (470) 18-1/2 (470) 18-1/2 (597) 23-1/2 (597) 23-1/2 (597) 23-1/2 (597) 3-1/4 (83) 3-1/4 (83) 4-1/4 (108) 4-1/4 (108) 3-1/4 (83) 5-1/2 (140) 5-1/2 (140) N P Q R(b) S 38-3/4 (984) 38-3/4 (984) 44-3/4 (1137) 48-3/4 (1238) 56-3/4 (1441) 56-3/4 (1441) 18-3/4 (476) 18-3/4 (476) 21-3/4 (552) 23-3/4 (603) 31-3/4 (806) 37-3/4 (959) 13-5/8 (346) 13-5/8 (346) 16-5/8 (422) 17-5/8 (448) 19-5/8 (498) 19-5/8 (498) 18-1/2 (470) 18-1/2 (470) 18-1/2 (470) 23-1/2 (597) 23-1/2 (597) 23-1/2 (597) 3-1/4 (83) 3-1/4 (83) 4-1/4 (108) 3-1/4 (83) 5-1/2 (140) 5-1/2 (140) Notes: 1. All dimensions are in inches followed by millimeters in parenthesis. 2. Access to the unit for service purposes should be provided at installation. Horizontal units require an 18 in. (457 mm) surround clearance from other mechanical and electrical equipment to enable panel removal from the unit for service/maintenance ability. NEC requires 36 in. clearance on the control panel side of the unit. Some local codes require a greater service clearance. Check all code requirements prior to unit installations. Installer is responsible for following all local and NEC code requirements. 3. Equipment containing a same-side supply/return combination requires a 3 in. (229 mm) clearance on one side. Access to the TXV may not be possible with this 3 in. (229 mm) clearance. 4. If hot gas reheat is specified for a size 018, 024, the actual cabinet size increases to an 036 cabinet. (a) Return air opening dimension (b) Filter rack dimension WSHP-SVX01N-EN 19 Unit Dimensions and Weights Figure 10. Right return/back supply (GEH/EXH) S R P B TOP N A FXG OPENING 1" (25.4) C E D BLOWER ACCESS PANEL HI VOLT REFRIG AND CONTROL ACCESS 14" (356) Q WCI mounting location L (W.O.) J DRAIN 3/4" (19) NPTI BACK LEFT SIDE FRONT M (W.I.) 1" (25.4) 6 3/4" (171) 1/2" (13) LO VOLT H K 1 3/8" (35) RIGHT SIDE 7" (178) H Table 8. GEH Unit Right return/back supply (GEH/EXH) A B C D(a) E FxG H J K Hi-048, 060 40 (1016) 40 (1016) 46 (1168) 46 (1168) 50 (1270) 58 (1473) 58 (1473) 20 (508) 20 (508) 23 (584) 23 (584) 25 (635) 33 (838) 33 (838) 15 (381) 15 (381) 18 (457) 18 (457) 19 (483) 21 (533) 21 (533) 20 (508) 20 (508) 23 (584) 23 (584) 25 (635) 29-1/2 (597) 29-1/2 (597) 15 (381) 15 (381) 18 (457) 18 (457) 20 (508) 23-1/2 (749) 23-1/2 (749) 8 x 6-3/4 (203) x (171) 9-1/2 x 6-3/4 (241) x (171) 9-1/2 x 8-1/8 (241) x (206) 11-1/4 x 8-1/4 (286) x (210) 13-1/2 x 10-1/2 (343) x (267) 13-1/8 x 11-1/4 (333) x (286) 13-1/2 x 13-3/4 (343) x (349) 11-1/2 (292) 11-1/2 (292) 13-1/2 (343) 13-1/2 (343) 17 (432) 18 (457) 18 (457) 4-1/2 (114) 4-1/2 (114) 4-3/4 (121) 4-3/4 (121) 4 (102) 5-1/8 (130) 5-1/8 (130) 1-5/8 (41) 1-5/8 (41) 3-1/4 (83) 3-1/4 (83) 1 (25) 1-1/2 (38) 1-1/2 (38) EXH Unit A B C D(a) E FxG H J K 40 (1016) 40 (1016) 46 (1168) 50 (1270) 58 (1473) 58 (1473) 20 (508) 20 (508) 23 (584) 25 (635) 33 (838) 39 (991) 11-1/2 (292) 11-1/2 (292) 13-1/2 (343) 17 (432) 18 (457) 18 (457) 4-1/2 (114) 4-1/4 (108) 4-3/4 (121) 4 (102) 9-3/4 (248) 9-3/4 (248) 1-3/4 (45) 2-3/4 (70) 3-1/4 (83) 1 (25) 1-1/2 (38) 1-1/2 (38) 006,009 012,015 018 024,030 036,042 Std-048 006-009 012-015 018-024 030-036 042-070 070 15 20 15 6-7/8 x 8 (381) (508) (381) (175) x (203) 15 20 15 8-1/4 x 9-3/4 (381) (508) (381) (210) x (248) 18 23 18 8-1/4 x 11-3/8 (457) (584) (457) (210) x (289) 19 25 20 10-1/2 x 13-1/2 (483) (635) (508) (267) x (343) 21 29-1/2 23-1/2 13-1/8 x 11-3/8 (533) (597) (749) (333) x (289) 21 29-1/2 23-1/2 13-7/8 x 13-7/8 (533) (597) (749) (352) x (352) L M NPTI NPTI 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 1 (25) 1 (25) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 1 (25) 1 (25) L M NPTI NPTI 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25) 1 (25) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25) 1 (25) N P Q R(b) S 38-3/4 (984) 38-3/4 (984) 44-3/4 (1137) 44-3/4 (1137) 48-3/4 (1238) 56-3/4 (1441) 56-3/4 (1441) 18-3/4 (476) 18-3/4 (476) 21-3/4 (552) 21-3/4 (552) 23-3/4 (603) 31-3/4 (806) 31-3/4 (806) 13-5/8 (346) 13-5/8 (346) 16-5/8 (422) 16-5/8 (422) 17-5/8 (448) 19-5/8 (498) 19-5/8 (498) 18-1/2 (470) 18-1/2 (470) 18-1/2 (470) 18-1/2 (597) 23-1/2 (597) 23-1/2 (597) 23-1/2 (597) 3-1/4 (83) 3-1/4 (83) 4-1/4 (108) 4-1/4 (108) 3-1/4 (83) 5-1/2 (140) 5-1/2 (140) N P Q R(b) S 38-3/4 (984) 38-3/4 (984) 44-3/4 (1137) 48-3/4 (1238) 56-3/4 (1441) 56-3/4 (1441) 18-3/4 (476) 18-3/4 (476) 21-3/4 (552) 23-3/4 (603) 31-3/4 (806) 37-3/4 (959) 13-5/8 (346) 13-5/8 (346) 16-5/8 (422) 17-5/8 (448) 19-5/8 (498) 19-5/8 (498) 18-1/2 (470) 18-1/2 (470) 18-1/2 (470) 23-1/2 (597) 23-1/2 (597) 23-1/2 (597) 3-1/4 (83) 3-1/4 (83) 4-1/4 (108) 3-1/4 (83) 5-1/2 (140) 5-1/2 (140) Notes: 1. All dimensions are in inches followed by millimeters in parenthesis. 2. Access to the unit for service purposes should be provided at installation. Horizontal units require an 18 in. (457 mm) surround clearance from other mechanical and electrical equipment to enable panel removal from the unit for service/maintenance ability. NEC requires 36 in. clearance on the control panel side of the unit. Some local codes require a greater service clearance. Check all code requirements prior to unit installations. Installer is responsible for following all local and NEC code requirements. 3. Equipment containing a same-side supply/return combination requires a 3 in. (229 mm) clearance on one side. Access to the TXV may not be possible with this 3 in. (229 mm) clearance. 4. If hot gas reheat is specified for a size 018, 024, the actual cabinet size increases to an 036 cabinet. (a) Return air opening dimension (b) Filter rack dimension 20 WSHP-SVX01N-EN Unit Dimensions and Weights Figure 11. Right return/right supply (GEH/EXH) S R P B TOP N A BLOWER ACCESS PANEL D 6 3/4" (171) 1" (25.4) E C REFRIG AND CONTROL ACCESS Q HI VOLT WCI mounting location LO VOLT FRONT L (W.O.) M (W.I.) 1/2" (13) DRAIN 3/4" (19) NPTI FXG OPENING 1" (25.4) LEFT SIDE BACK H Table 9. A 40 006, 009 (1016) 40 012, 015 (1016) 46 018 (1168) 46 024, 030 (1168) 50 036, 042 (1270) 58 Std-048 (1473) 58 Hi-048, 060 (1473) EXH Unit 012-015 018-024 030-036 042-070 070 J Right return/right supply (GEH/EXH) GEH Unit 006-009 H RIGHT SIDE K 7" (178) 1 3/8" (35) 14" (356) B 20 (508) 20 (508) 23 (584) 23 (584) 25 (635) 33 (838) 33 (838) A B 40 (1016) 40 (1016) 46 (1168) 50 (1270) 58 (1473) 58 (1473) 20 (508) 20 (508) 23 (584) 25 (635) 33 (838) 39 (991) C D(a) E FxG 15 20 15 6-7/8 x 8 (381) (508) (381) (175) x (203) 15 20 15 6-7/8 x 9-7/8 (381) (508) (381) (175) x (251) 18 23 18 8-1/4 x 9-3/4 (457) (584) (457) (210) x (248) 18 23 18 8-1/4 x 11-3/8 (457) (584) (457) (210) x (289) 19 25 20 10-1/2 x 13-1/2 (483) (635) (508) (267) x (343) 21 29-1/2 23-1/2 13-1/8 x 11-3/8 (533) (597) (749) (333) x (289) 21 29-1/2 23-1/2 13-7/8 x 13-7/8 (533) (597) (749) (352) x (352) C D(a) E FxG 15 20 15 6-7/8 x 8 (381) (508) (381) (175) x (203) 15 20 15 8-1/4 x 9-3/4 (381) (508) (381) (210) x (248) 18 23 18 8-1/4 x 11-3/8 (457) (584) (457) (210) x (289) 19 25 20 10-1/2 x 13-1/2 (483) (635) (508) (267) x (343) 21 29-1/2 23-1/2 13-1/8 x 11-3/8 (533) (597) (749) (333) x (289) 21 29-1/2 23-1/2 13-7/8 x 13-7/8 (533) (597) (749) (352) x (352) H J 11-1/2 (292) 11-1/2 (292) 13-1/2 (343) 13-1/2 (343) 17 (432) 18 (457) 18 (457) 4-1/2 (114) 4-1/4 (108) 4-3/4 (121) 4-3/4 (121) K 1-3/4 (45) 2-3/4 (70) 3-1/4 (83) 3-1/4 (83) 1 4 (102) (25) 5-1/4 1-1/2 (133) (38) 5-1/4 1-1/2 (133) (38) H J K 11-1/2 (292) 11-1/2 (292) 13-1/2 (343) 17 (432) 18 (457) 18 (457) 4-1/2 (114) 4-1/4 (108) 4-3/4 (121) 4 (102) 5-1/4 (133) 5-1/4 (133) 1-3/4 (45) 2-3/4 (70) 3-1/4 (83) 1 (25) 1-1/2 (38) 1-1/2 (38) L M NPTI NPTI 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 1 (25) 1 (25) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 1 (25) 1 (25) L M NPTI NPTI 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25) 1 (25) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25) 1 (25) N P Q R(b) S 38-3/4 (984) 38-3/4 (984) 44-3/4 (1137) 44-3/4 (1137) 48-3/4 (1238) 56-3/4 (1441) 56-3/4 (1441) 18-3/4 (476) 18-3/4 (476) 21-3/4 (552) 21-3/4 (552) 23-3/4 (603) 31-3/4 (806) 31-3/4 (806) 13-5/8 (346) 13-5/8 (346) 16-5/8 (422) 16-5/8 (422) 17-5/8 (448) 19-5/8 (498) 19-5/8 (498) 18-1/2 (470) 18-1/2 (470) 18-1/2 (470) 18-1/2 (597) 23-1/2 (597) 23-1/2 (597) 23-1/2 (597) 3-1/4 (83) 3-1/4 (83) 4-1/4 (108) 4-1/4 (108) 3-1/4 (83) 5-1/2 (140) 5-1/2 (140) N P Q R(b) S 38-3/4 (984) 38-3/4 (984) 44-3/4 (1137) 48-3/4 (1238) 56-3/4 (1441) 56-3/4 (1441) 18-3/4 (476) 18-3/4 (476) 21-3/4 (552) 23-3/4 (603) 31-3/4 (806) 37-3/4 (959) 13-5/8 (346) 13-5/8 (346) 16-5/8 (422) 17-5/8 (448) 19-5/8 (498) 19-5/8 (498) 18-1/2 (470) 18-1/2 (470) 18-1/2 (470) 23-1/2 (597) 23-1/2 (597) 23-1/2 (597) 3-1/4 (83) 3-1/4 (83) 4-1/4 (108) 3-1/4 (83) 5-1/2 (140) 5-1/2 (140) Notes: 1. All dimensions are in inches followed by millimeters in parenthesis. 2. 2. Access to the unit for service purposes should be provided at installation. Horizontal units require an 18 in. (457 mm) surround clearance from other mechanical and electrical equipment to enable panel removal from the unit for service/maintenance ability. NEC requires 36 in. clearance on the control panel side of the unit Some local codes require a greater service clearance. Check all code requirements prior to unit installations. Installer is responsible for following all local and NEC code requirements. 3. Equipment containing a same-side supply/return combination requires a 3 in. (229 mm) clearance on one side. Access to the TXV may not be possible with this 3 in. (229 mm) clearance. 4. If hot gas reheat is specified for a size 018, 024, the actual cabinet size increases to an 036 cabinet. 5. When a horizontal model is ordered with the same side return and supply in a ducted application, bottom filter removal is required due to limited access on either side of the filter. (a) Return air opening dimension (b) Filter rack dimension Note: It is recommended to order a bottom access filter rack with right return/right supply combination due to potential problem with return air filter removal. WSHP-SVX01N-EN 21 Unit Dimensions and Weights Figure 12. Left return/top supply: GEVE—“A” and later design sequence; EXV—“A” and later design sequence D L F K D E M J TOP BLOWER ACCESS H B COMP/CONTROL ACCESS W.O. WCI mounting location DRAIN HI VOLT 8 3/4" (222) 12" 9 1/2" (305) (241) G 3 5/8" (92) LO VOLT 3 5/8" (92) LEFT SIDE W.I. A C FRONT RIGHT SIDE Table 10. Left return/top supply: GEVE—“A” and later design sequence; EXV—“A” and later design sequence W.I. W.O. Drain NPTI NPTI FPT GEV Unit A B C D E F G H J K L M 006-015 19-1/2 (495) 31-1/4 (794) 21-1/2 (546) 11-1/2 (292) 4 (102) 5-3/4 (146) 9-1/2 (241) 15 (381) 17 (432) 6-7/8 (175) 8 (203) 3/4 (19) 1/2 (12.7) 1/2 (12.7) 3/4 (19) 018, 024, 030 21-1/2 (546) 39-1/4 (997) 21-1/2 (546) 13-1/2 (343) 4 (102) 4 (1021) 9-1/2 (241) 23-3/4 (603) 17 (432) 8-1/4 (368) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 036, 042 24-1/2 (622) 41-7/8 (1064) 26-1/2 (673) 18 (457) 3-1/4 (83) 5-3/4 (146) 9-1/2 (241) 19 (483) 23 (584) 10-1/2 (267) 13-1/2 (343) 1/4 (6) 3/4 (19) 3/4 (19) 3/4 (19) Std-048 26-1/2 (673) 46-7/8 (1191) 30-1/2 (775) 18 (457) 4-1/4 (108) 2 (51) 9-1/2 (241) 29 (737) 27-7/8 (708) 13-7/8 (352) 13-7/8 (352) 1/2 (13) 1 (25.4) 1 (25.4) 3/4 (19) Hi-048, 060 26-1/2 (673) 46-7/8 (1191) 30-1/2 (775) 18 (457) 4-1/4 (108) 2 (51) 9-1/2 (241) 29 (737) 27-7/8 (708) 13-1/8 (333) 11-3/8 (289) 1/2 (13) 1 (25.4) 1 (25.4) 3/4 (19) EXV Unit A B C D E F G H J K L M 006-009 19-1/2 (495) 31-1/4 (794) 21-1/2 (546) 11-1/2 (292) 4 (102) 5-3/4 (146) 9-1/2 (241) 15 (381) 17 (432) 6-7/8 (175) 8 (203) 3/4 (19) 1/2 (13) 1/2 (13) 3/4 (19) 012-015 19-1/2 (495) 31-1/4 (794) 21-1/2 (546) 11-1/2 (292) 5-1/2 (140) 5-5/8 (142) 9-1/2 (241) 15 (381) 17 (432) 8-1/4 (210) 9-3/4 (248) 3/4 (19) 1/2 (13) 1/2 (13) 3/4 (19) 018-024 21-1/2 (546) 39-1/4 (997) 21-1/2 (546) 13-1/2 (343) 4 (102) 4 (1021) 9-1/2 (241) 23-3/4 (603) 17 (432) 8-1/4 (368) 11-3/8 (289) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 030-036 24-1/2 (622) 41-7/8 (1064) 26-1/2 (673) 18 (457) 3-1/4 (83) 5-3/4 (146) 9-1/2 (241) 19 (483) 23 (584) 10-1/2 (267) 13-1/2 (343) 1/4 (6) 3/4 (19) 3/4 (19) 3/4 (19) 042-060 26-1/2 (673) 46-7/8 (1191) 30-1/2 (775) 18 (457) 4-1/4 (108) 2 (51) 9-1/2 (241) 29 (737) 27-7/8 (708) 13-7/8 (352) 11-3/8 (289) 1/2 (13) 1 (25.4) 1 (25.4) 3/4 (19) 070 26-1/2 (673) 50-7/8 (1292) 30-1/2 (775) 18 (457) 4-1/4 (108) 2 (51) 9-1/2 (241) 29 (737) 27-7/8 (708) 13-1/8 (333) 11-3/8 (289) 1/2 (13) 1 (25.4) 1 (25.4) 3/4 (19) 9-3/4 (248) 11-3/8 (289) W.I. W.O. Drain NPTI NPTI FPT Notes: 1. All dimensions are in inches followed by millimeters in parenthesis. 2. Access to the unit for service purposes should be provided at installation. Vertical units require an 24 in. (610 mm) surround clearance from other mechanical and electrical equipment to enable panel removal from the unit for service/maintenance ability. NEC requires 36 in. clearance on the control panel side of the unit. Some local codes require a greater service clearance. Check all code requirements prior to unit installations. Installer is responsible for following all local and NEC code requirements. 3. Units in a free return application will require more than a 1 in. (25.4 mm) clearance to provide proper air flow to the unit’s air-to-refrigerant coil. 22 WSHP-SVX01N-EN Unit Dimensions and Weights Figure 13. Left return/back supply: GEVE—“A” and later design sequence; EXV—“A” and later design sequence D E M j TOP F BLOWER ACCESS D H B COMP/CONTROL ACCESS WCI mounting location W.O. DRAIN HI VOLT 8 3/4" (222) 12" (305) LO VOLT 3 5/8" (92) 9 1/2" (241) G 3 5/8" (92) W.I. A LEFT SIDE C FRONT RIGHT SIDE Table 11. Left return/back supply: GEVE—“A” and later design sequence; EXV—“A” and later design sequence GEV Unit A B C D E F 006-015 19-1/2 (495) 31-1/4 (794) 21-1/2 (546) 4 1-3/4 (102) (44) 006-009 006-009 11-1/2 (292) 4-3/4 3-3/4 (121) (95) 012-015 012-015 018, 024, 030 21-1/2 (546) 39-1/4 (997) 21-1/2 (546) 13-1/2 (343) 24-1/2 (622) 26-1/2 Std-048 (673) 26-1/2 Hi-048, 060 (673) 41-7/8 (1064) 46-7/8 (1191) 46-7/8 (1191) 26-1/2 18 (457) (673) 30-1/2 18 (457) (775) 30-1/2 18 (457) (775) 036, 042 EXV Unit 006-009 012-015 018-024 030-036 042-060 070 G H J K L M 9-1/2 (241) 15 (381) 17 (432) 6-7/8 (175) 8 (203) 3/4 (19) 4 (102) 3-7/8 (98) 9-1/2 (241) 3-1/4 (83) 4-1/4 (108) 4-1/4 (108) 1-7/8 (48) 2 (51) 2 (51) 9-1/2 (241) 9-1/2 (241) 9-1/2 (241) 23-3/4 17 (432) (603) 19 (483) 23 (584) 27-7/8 (708) 27-7/8 29 (737) (708) 29 (737) W.I. NPTI W.O. Drain NPTI FPT 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 10-1/2 (267) 13-7/8 (352) 13-1/8 (333) 9-3/4 (248) 11-3/8 (289) 13-1/2 (343) 13-7/8 (352) 11-3/8 (289) 1/4 (6) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 8-1/4 (368) 1 (25.4) 1 (25.4) 1 (25.4) 1 (25.4) A B C D E F G H J K L M W.I. NPTI W.O. Drain NPTI FPT 19-1/2 (495) 19-1/2 (495) 21-1/2 (546) 24-1/2 (622) 26-1/2 (673) 26-1/2 (673) 31-1/4 (794) 31-1/4 (794) 39-1/4 (997) 41-7/8 (1064) 46-7/8 (1191) 50-7/8 (1292) 21-1/2 (546) 21-1/2 (546) 21-1/2 (546) 26-1/2 (673) 30-1/2 (775) 30-1/2 (775) 11-1/2 (292) 11-1/2 (292) 13-1/2 (343) 18 (457) 18 (457) 18 (457) 4 (102) 5-1/4 (133) 4 (102) 3-1/4 (83) 4-1/4 (108) 4-1/4 (108) 1-3/4 (44) 3-3/4 (95) 3-7/8 (98) 1-7/8 (48) 2 (51) 2 (51) 9-1/2 (241) 9-1/2 (241) 9-1/2 (241) 9-1/2 (241) 9-1/2 (241) 9-1/2 (241) 15 (381) 15 (381) 23-3/4 (603) 19 (483) 29 (737) 29 (737) 17 (432) 17 (432) 17 (432) 23 (584) 27-7/8 (708) 27-7/8 (708) 6-7/8 (175) 8-1/4 (210) 8-1/4 (368) 10-1/2 (267) 13-7/8 (352) 13-1/8 (333) 8 (203) 9-3/4 (248) 11-3/8 (289) 13-1/2 (343) 11-3/8 (289) 11-3/8 (289) 3/4 (19) 3/4 (19) 3/4 (19) 1/4 (6) 1/2 (13) 1/2 (13) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25.4) 1 (25.4) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25.4) 1 (25.4) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) Note: 1. All dimensions are in inches followed by millimeters in parenthesis. 2. Access to the unit for service purposes should be provided at installation. Vertical units require an 24 in. (610 mm) surround clearance from other mechanical and electrical equipment to enable panel removal from the unit for service/maintenance ability. NEC requires 36 in. clearance on the control panel side of the unit. Some local codes require a greater service clearance. Check all code requirements prior to unit installations. Installer is responsible for following all local and NEC code requirements. 3. Units in a free return application will require more than a 1 in. (25.4 mm) clearance to provide proper air flow to the unit’s air-to-refrigerant coil. WSHP-SVX01N-EN 23 Unit Dimensions and Weights Figure 14. Right return/top supply: GEVE—“A” and later design sequence; EXV—”A” and later design sequence) F D L K D E J M TOP BLOWER ACCESS H B COMP/CONTROL ACCESS W.O. WCI mounting location DRAIN HI VOLT LO VOLT 3 5/8" (92) 8 3/4" (222) W.I. C 3 5/8" (92) 12" 9 1/2" (305) (241) G A FRONT LEFT SIDE RIGHT SIDE Table 12. Right return/top supply: GEVE—“A” and later design sequence; EXV—“A” and later design sequence W.I. W.O. Drain NPTI NPTI FPT GEV Unit A B C D E F G H J K L M 006-015 19-1/2 (495) 31-1/4 (794) 21-1/2 (546) 11-1/2 (292) 4 (102) 5-3/4 (146) 9-1/2 (241) 15 (381) 17 (432) 6-7/8 (175) 8 (203) 3/4 (19) 1/2 (13) 1/2 (13) 3/4 (19) 018, 024, 030 21-1/2 (546) 39-1/4 (997) 21-1/2 (546) 13-1/2 (343) 4 (102) 4 (1021) 9-1/2 (241) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 036, 042 24-1/2 (622) 41-7/8 (1064) 26-1/2 18 (457) (673) 3-1/4 (83) 5-3/4 (146) 9-1/2 (241) 19 (483) 23 (584) 10-1/2 (267) 13-1/2 (343) 1-3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) Std-048 26-1/2 (673) 46-7/8 (1191) 30-1/2 18 (457) (775) 4-1/4 (108) 2 (51) 9-1/2 (241) 29 (737) 27-7/8 (708) 13-7/8 (352) 13-7/8 (352) 1/2 (13) 1 (25) 1 (25) 3/4 (19) Hi-048, 060 26-1/2 (673) 46-7/8 (1191) 30-1/2 18 (457) (775) 4-1/4 (108) 2 (51) 9-1/2 (241) 29 (737) 27-7/8 (708) 13-1/8 (333) 11-3/8 (289) 1/2 (13) 1 (25) 1 (25) 3/4 (19) EXV Unit A B C D E F G H J K L M 006-009 19-1/2 (495) 31-1/4 (794) 21-1/2 (546) 11-1/2 (292) 4 (102) 5-3/4 (146) 9-1/2 (241) 15 (381) 17 (432) 6-7/8 (175) 8 (203) 3/4 (19) 1/2 (13) 1/2 (13) 3/4 (19) 012-015 19-1/2 (495) 31-1/4 (794) 21-1/2 (546) 11-1/2 (292) 2-1/2 (64) 5-5/8 (143) 9-1/2 (241) 15 (381) 17 (432) 8-1/4 (210) 9-3/4 (248) 3/4 (19) 1/2 (13) 1/2 (13) 3/4 (19) 018-024 21-1/2 (546) 39-1/4 (997) 21-1/2 (546) 13-1/2 (343) 4 (102) 4 (102) 9-1/2 (241) 23-3/4 (603) 17 (432) 8-1/4 (368) 11-3/8 (289) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 030-036 24-1/2 (622) 41-7/8 (1064) 26-1/2 (673) 18 (457) 3-1/4 (83) 5-3/4 (146) 9-1/2 (241) 19 (483) 23 (584) 10-1/2 (267) 13-1/2 (343) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 042-060 26-1/2 (673) 46-7/8 (1191) 30-1/2 (775) 18 (457) 4-1/4 (108) 2 (51) 9-1/2 (241) 29 (737) 27-7/8 (708) 13-7/8 (352) 11-3/8 (289) 1/2 (13) 1 (25.4) 1 (25.4) 3/4 (19) 070 26-1/2 (673) 50-7/8 (1292) 30-1/2 (775) 18 (457) 4-1/4 (108) 2 (51) 9-1/2 (241) 29 (737) 27-7/8 (708) 13-1/8 (333) 11-3/8 (289) 1/2 (13) 1 (25.4) 1 (25.4) 3/4 (19) 23-3/4 17 (432) (603) 8-1/4 (368) 9-3/4 (248) 11-3/8 (289) W.I. W.O. Drain NPTI NPTI FPT Note: 1. All dimensions are in inches followed by millimeters in parenthesis. 2. Access to the unit for service purposes should be provided at installation. Vertical units require an 24 in. (610 mm) surround clearance from other mechanical and electrical equipment to enable panel removal from the unit for service/maintenance ability. NEC requires 36 in. clearance on the control panel side of the unit. Some local codes require a greater service clearance. Check all code requirements prior to unit installations. Installer is responsible for following all local and NEC code requirements. 3. Units in a free return application will require more than a 1 in. (25.4 mm) clearance to provide proper air flow to the unit’s air-to-refrigerant coil. 24 WSHP-SVX01N-EN Unit Dimensions and Weights Figure 15. Right return/back supply: GEVE—“A” and later design sequence; EXV—“A” and later design sequence F D L K D E J M TOP BLOWER ACCESS H B COMP/CONTROL ACCESS W.O. WCI mounting location DRAIN HI VOLT LO VOLT 3 5/8" (92) 8 3/4" (222) W.I. C 3 5/8" (92) 12" 9 1/2" (305) (241) G A FRONT LEFT SIDE RIGHT SIDE Table 13. Right return/back supply: GEVE—“A” and later design sequence; EXV—“A” and later design sequence GEV Unit A B C D E F 006-015 19-1/2 (495) 31-1/4 (794) 21-1/2 (546) 4 1-3/4 (102) (44) 11-1/2 006-009 006-009 (292) 6 1-1/4 (152) (32) 012-015 012-015 018, 024, 030 21-1/2 (546) 39-1/4 (997) 21-1/2 (546) 13-1/2 (343) 24-1/2 (622) 26-1/2 Std-048 (673) 26-1/2 Hi-048, 060 (673) 41-7/8 (1064) 46-7/8 (1191) 46-7/8 (1191) 26-1/2 18 (457) (673) 30-1/2 18 (457) (775) 30-1/2 18 (457) (775) 036, 042 EXV Unit A 19-1/2 (495) 19-1/2 012-015 (495) 21-1/2 018-024 (546) 24-1/2 030-036 (622) 26-1/2 042-060 (673) 26-1/2 070 (673) Note: All dimensions 006-009 WSHP-SVX01N-EN B C D G H J K L M 8 (203) 3/4 (19) 9-1/2 (241) 15 (381) 17 (432) 6-7/8 (175) 23-3/4 17 (432) (603) 8-1/4 (368) 4 (102) 3-7/8 (98) 9-1/2 (241) 3-1/4 (83) 4-1/4 (108) 4-1/4 (108) 1-7/8 (48) 2 (51) 2 (51) 9-1/2 (241) 9-1/2 (241) 9-1/2 (241) 19 (483) 29 (737) 29 (737) E F G 31-1/4 21-1/2 11-1/2 4 1-3/4 9-1/2 (794) (546) (292) (102) (44) (241) 31-1/4 21-1/2 11-1/2 2 1-1/4 9-1/2 (794) (546) (292) (51) (32) (241) 39-1/4 21-1/2 13-1/2 4 3-7/8 9-1/2 (997) (546) (343) (102) (98) (241) 41-7/8 26-1/2 18 3-1/4 1-7/8 9-1/2 (1064) (673) (457) (83) (48) (241) 46-7/8 30-1/2 18 4-1/4 2 9-1/2 (1191) (775) (457) (108) (51) (241) 50-7/8 30-1/2 18 4-1/4 2 9-1/2 (1292) (775) (457) (108) (51) (241) are in inches followed by millimeters in parenthesis. 9-3/4 (248) W.I. NPTI W.O. Drain NPTI FPT 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 27-7/8 (708) 27-7/8 (708) 10-1/2 (267) 13-7/8 (352) 13-1/8 (333) 11-3/8 (289) 13-1/2 (343) 13-7/8 (352) 11-3/8 (289) 1-3/4 (19) 1/2 (13) 1/2 (13) 3/4 (19) 1 (25) 1 (25) 3/4 (19) 1 (25) 1 (25) 3/4 (19) 3/4 (19) 3/4 (19) H J K L M W.I. NPTI W.O. Drain NPTI FPT 15 (381) 15 (381) 23-3/4 (603) 19 (483) 29 (737) 29 (737) 17 (432) 17 (432) 17 (432) 23 (584) 27-7/8 (708) 27-7/8 (708) 6-7/8 (175) 8-1/4 (210) 8-1/4 (368) 10-1/2 (267) 13-7/8 (352) 13-1/8 (333) 8 (203) 9-3/4 (248) 11-3/8 (289) 13-1/2 (343) 11-3/8 (289) 11-3/8 (289) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 1/2 (13) 1/2 (13) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25.4) 1 (25.4) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19) 1 (25.4) 1 (25.4) 23 (584) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 25 Unit Dimensions and Weights Figure 16. GEH 6-10 tons (072-120) 60 Hz; GEH 6-7½ tons (072-090) 50 Hz—right return/left supply 20" (508) SERVICE CLEARANCE 36" (914) SERVICE CLEARANCE 4 5/8" (117) 79" (2007) 74 1/2" (1892) 1 3/4" (44) 36" (914) 2 1/8" (54) 23 7/8" (606) BLOWER ACCESS PANEL 40 5/8" (1032) 7 5/8" (194) TOP VIEW 18 3/8" (467) 81" (2057) 85" (2159) 1 1/4" (32) 5/8" (16) W.O. "D" NPTI 1" (25.4) 24 VOLT 1 1/8" (28.6) DIA. A 1 1/2" (38) ) 4 7/8" (124) 14 1/2" (368) 18 3/4" (476) 23 1/4" 16 1/2" (591) (419) WCI mounting location B BACK SIDE 2 1/4" (57) DRAIN CONNECTION 1/2" (22) SCHEDULE 40 PVC HIGH VOLTAGE 7/8" (22.2) DIA. W.I. "D" NPTI 6 1/2" (165) 3 1/8" (79) C LEFT SIDE (79 RETURN AIR OPENING 1" (25.4) DIA. MOUNTING HOLE 4X'S SUPPLY OPENING 1" (25.4) DUCT FLANGE Table 14. GEH 6–10 tons (072-120) 60 Hz; GEH 6–7½ tons (072-090) 50 Hz—right return/left supply GEH (60 Hz) 26 GEH (50 Hz) A B C D 072 — 36-1/4 in. (921 mm) 15-5/8 in. (397 mm) 6-5/8 in. (168 mm) 1-1/4 in. (32 mm) 090 072 36-1/8 in. (917 mm) 12-3/4 in. (324 mm) 6-3/4 in. (171 mm) 1-1/4 in. (32 mm) 120 090 36-1/8 in. (917 mm) 13 in. (330 mm) 7-1/4 in. (184 mm) 1-1/2 in. (38 mm) WSHP-SVX01N-EN Unit Dimensions and Weights Figure 17. GEH 6–10 tons (072–120) 60 Hz; GEH 6–7½ tons (072–090) 50 Hz—right return/back supply 36" (914) SERVICE CLEARANCE 74 1/2" (1892) 1 3/4" (44) 36" (914) 18 3/8" (467) 81" (2057) 85" (2159) 6 1/8" (156) 2 1/8" (54) 23 7/8" (606) 4 5/8" (117) 79" (2007) BLOWER ACCESS PANEL 40 5/8" (1032) 20" (508) SERVICE CLEARANCE TOP VIEW 4 7/8" (124) 1 1/4" (32) 5/8" (16) W.O. "D" NPTI 24 VOLT 1 1/8" (28.6) DIA. A 14 1/2" (368) 18 3/4" (476) 1 1/2" (38) 23 1/4" 16 1/2" (591) (419) WCI mounting location B HIGH VOLTAGE 7/8" (22.2) DIA. W.I. "D" NPTI 6 1/2" (165) DRAIN CONNECTION 1/2" (22) SCHEDULE 40 PVC 2 1/4" (57) 3 1/8" (79) C LEFT SIDE RETURN AIR OPENING 1" (25.4) DIA. MOUNTING HOLE 4X'S SUPPLY OPENING 1" (25.4) DUCT FLANGE Table 15. GEH 6-10 tons (072-120) 60 Hz; GEH 6-7½ tons (072-090) 50 Hz—right return/back supply GEH (60 Hz) GEH (50 Hz) A B C D 072 — 36-1/4 in. (921 mm) 15-5/8 in. (397 mm) 6-5/8 in. (168 mm) 1-1/4 in. (32 mm) 090 072 36-1/8 in. (917 mm) 12-3/4 in. (324 mm) 6-3/4 in. (171 mm) 1-1/4 in. (32 mm) 120 090 36-1/8 in. (917 mm) 13 in. (330 mm) 7-1/4 in. (184 mm) 1-1/2 in. (38 mm) WSHP-SVX01N-EN 27 Unit Dimensions and Weights Figure 18. GEH 6-10 tons (072-120) 60 Hz; GEH 6-7½ tons (072-090) 50 Hz - left return/right supply 36" (914) SERVICE CLEARANCE 79" (2007) 4 5/8" (117) 40 5/8" (1032) 20" (508) SERVICE CLEARANCE 74 1/2" (1892) 1 3/4" (44) 36" (914) 24 3/4" (629) 1 1/4" (32) 7 5/8" (194) TOP VIEW BLOWER ACCESS PANEL 18 3/8" (467) 81" (2057) 85" (2159) 23 1/4" (591) 16 1/2" (419) A 1" (25.4) 5/8" (16) 24 VOLT 1 1/8" (28.6) DIA. 1 1/4" (32) W.O. "D" NPTI 1 1/2" (38) 4 7/8" (124) 14 1/2" (368) WCI mounting location 18 3/4" (476) B HIGH VOLTAGE 7/8" (22.2) DIA. 3 1/8" (79) 6 1/2" (165) 2 1/4" (57) C DRAIN CONNECTION 1/2" (22) SCHEDULE 40 PVC W.I. "D" NPTI LEFT SIDE BACK SIDE RETURN AIR OPENING SUPPLY OPENING 1" (25.4) DUCT FLANGE 1" (25.4) DIA. MOUNTING HOLE 4X'S Table 16. GEH 6-10 tons (072-120) 60 Hz; GEH 6-7½ tons (072-090) 50 Hz—left return/right supply GEH (60 Hz) 28 GEH (50 Hz) A B C D 072 — 36-1/8 in. (917 mm) 17 in. (432 mm) 8 in. (203 mm) 1-1/4 in. (32 mm) 090 072 36-1/8 in. (917 mm) 13-3/4 in. (349 mm) 7-3/4 in. (197 mm) 1-1/4 in. (32 mm) 120 090 36-1/8 in. (917 mm) 13 in. (330 mm) 7-1/4 in. (184 mm) 1-1/2 in. (38 mm) WSHP-SVX01N-EN Unit Dimensions and Weights Figure 19. GEH 6-10 tons (072-120) 60 Hz; GEH 6-7½ tons (072-090) 50 Hz—left return/back supply 36" (914) SERVICE CLEARANCE 1 3/4" (44) 36" (914) 18 3/8" (467) 81" (2057) 85" (2159) 20" (508) SERVICE CLEARANCE 6 1/8" (156) 40 5/8" (1032) 74 1/2" (1892) 24 3/4" (629) 1 1/4" (32) 4 5/8" (117) 79" (2007) TOP VIEW BLOWER ACCESS PANEL 23 1/4" (591) 16 1/2" (419) A 5/8" (16) 24 VOLT 1 1/8" (28.6) DIA. 1 1/4" (32) W.O. "D" NPTI 1 1/2" (38) 4 7/8" (124) 14 1/2" (368) WCI mounting location 18 3/4" (476) B HIGH VOLTAGE 7/8" (22.2) DIA. DRAIN CONNECTION 1/2" (22) SCHEDULE 40 PVC W.I. "D" NPTI LEFT SIDE 3 1/8" (79) 2 1/4" (57) 6 1/2" (159) C RETURN AIR OPENING 1" (25.4) DIA. MOUNTING HOLE 4X'S SUPPLY OPENING 1" (25.4) DUCT FLANGE Table 17. GEH 6-10 tons (072-120) 60 Hz; GEH 6-7½ tons (072-090) 50 Hz—left return/back supply GEH (60 Hz) GEH (50 Hz) A B C D 072 — 36-1/8 in. (917 mm) 17 in. (432 mm) 8 in. (203 mm) 1-1/4 in. (32 mm) 090 072 36-1/8 in. (917 mm) 13-3/4 in. (349 mm) 7-3/4 in. (197 mm) 1-1/4 in. (32 mm) 120 090 36-1/8 in. (917 mm) 13 in. (330 mm) 7-1/4 in. (184 mm) 1-1/2 in. (38 mm) WSHP-SVX01N-EN 29 Unit Dimensions and Weights Figure 20. GEH 12½-15 tons (150-180) 60 Hz; GEH 10-12½ tons (120-150) 50 Hz—right return/left supply 20" (508) SERVICE CLEARANCE 36" (914) SERVICE CLEARANCE 4 5/8" (117) 79" (2007) 74 1/2" (1892) 1 3/4" (44) 36" (914) 2 1/8" (54) 23 7/8" (606) BLOWER ACCESS PANEL 40 5/8" (1032) 7 5/8" (194) TOP VIEW 18 3/8" (467) 81" (2057) 85" (2159) 24 VOLT 1 1/8" (28.6) DIA. A 1 1/2" (38) ) 4 7/8" (124) 1 1/4" (32) 5/8" (16) W.O. "D" NPTI 1" (25.4) 14 1/2" (368) 18 3/4" (476) 23 1/4" 16 1/2" (591) (419) WCI mounting location B BACK SIDE HIGH VOLTAGE 7/8" (22.2) DIA. W.I. "D" NPTI 6 1/2" (165) DRAIN CONNECTION 1/2" (22) SCHEDULE 40 PVC 2 1/4" (57) 3 1/8" (79) C LEFT SIDE (79 RETURN AIR OPENING 1" (25.4) DIA. MOUNTING HOLE 4X'S 30 SUPPLY OPENING 1" (25.4) DUCT FLANGE WSHP-SVX01N-EN Unit Dimensions and Weights Figure 21. GEH 12½-15 tons (150-180) 60 Hz; GEH 10-12½ tons (120-150) 50 Hz—right return/back supply 36" (914) SERVICE CLEARANCE 74 1/2" (1892) 2" (41) 46 5/8" 42" (1184) (1067) 21 3/8" (543) 87" (2210) 91" (2311) 7 1/8" (181) 2 1/4" (57) 29 3/4" (756) 4 5/8" (117) 85" (2159) 20" (508) SERVICE CLEARANCE TOP VIEW W.O. 1 1/2" (38) NPTI 24 VOLT 1 1/8" (28.6) DIA. 61 1/4" (1556) 16 3/4" (425) 23 3/4" (603) 1 1/2" (38) 30 1/4" 22 3/4" (768) (578) WCI mounting location DRAIN CONNECTION 1/2" (22) SCHEDULE 40 PVC W.I. 1 1/2" (38) NPTI HIGH VOLTAGE 7/8" (22.2) DIA. 2 1/4" (57) 3 1/8" (79) 24 7/8" (632) 5 5/8" (143) 9 1/8" (232) 4 7/8" (124) 2" (51) 1 3/8" (35) BLOWER ACCESS PANEL LEFT SIDE RETURN AIR OPENING 1" (25.4) DIA. MOUNTING HOLE 4X'S WSHP-SVX01N-EN SUPPLY OPENING 1" (25.4) DUCT FLANGE 31 Unit Dimensions and Weights Figure 22. GEH 12½-15 tons (150-180) 60 Hz; GEH 10-12½ tons (120-150) 50 Hz—left return/right supply 36" (914) SERVICE CLEARANCE 85" (2159) 4 5/8" (117) 74 1/2" (1892) 2" (51) 42" (1067) 29 3/4" (756) 7 1/8" (181) TOP VIEW 2 1/4" (57) 46 5/8" (1184) 20" (508) SERVICE CLEARANCE BLOWER ACCESS PANEL 21 3/8" (543) 87" (2210) 1" (25.4) 4 7/8" (124) 16 3/4" (425) WCI mounting location 23 3/4" (603) 24 7/8" (632) HIGH VOLTAGE 7/8" (22.2) DIA. LEFT SIDE 3 1/8" (79) 5 5/8" (143) 2 1/4" (57) 9 1/8" (232) 30 1/4" (768) 22 3/4" (578) 39 1/2" (1003) 1 3/8" (35) 2 1/8" (54) W.O. 1 1/2" (38) NPTI 24 VOLT 1 1/8" (28.6) DIA. 2" (51) 91" (2311) W.I. 1 1/2" (38) NPTI DRAIN CONNECTION 1/2" (22) SCHEDULE 40 PVC BACK SIDE RETURN AIR OPENING SUPPLY OPENING 1" (25.4) DUCT FLANGE 1" (25.4) DIA. MOUNTING HOLE 4X'S 32 WSHP-SVX01N-EN Unit Dimensions and Weights Figure 23. GEH 12½-15 tons (150-180) 60 Hz; GEH 10-12½ tons (120-150) 50 Hz—left return/back supply 36" (914) SERVICE CLEARANCE 2" (51) 42" (1067) 21 3/8" (543) 87" (2210) 91" (2311) 20" (508) SERVICE CLEARANCE 29 3/4" (756) 7 1/8" (181) 46 5/8" (1184) 74 1/2" (1892) 2 1/4" (57) 4 5/8" (117) 85" (2159) TOP VIEW BLOWER ACCESS PANEL 4 7/8" (124) 16 3/4" (425) WCI mounting location 23 3/4" (603) 24 7/8" (632) HIGH VOLTAGE 7/8" (22.2) DIA. LEFT SIDE W.I. 1 1/2" (38) NPTI DRAIN CONNECTION 1/2" (22) SCHEDULE 40 PVC 3 1/8" (79) 5 5/8" (143) 2 1/4" (57) 9 1/8" (232) 30 1/4" (768) 22 3/4" (578) 39 1/2" (1003) 1 3/8" (35) 24 VOLT 1 1/8" (28.6) DIA. 2 1/8" (54) 2" (51) W.O. 1 1/2" (38) NPTI RETURN AIR OPENING 1" (25.4) DIA. MOUNTING HOLE 4X'S WSHP-SVX01N-EN SUPPLY OPENING 1" (25.4) DUCT FLANGE 33 Unit Dimensions and Weights Figure 24. GEV 6-10 tons (072-120) 60 Hz; 6 and 7½ tons (072 and 090) 50 Hz—front return/back supply(a) 15 3/4 (400) ACCESS PANEL FOR SHEAVES AND BELTS SUPPLY OPENING 1" (25.4) DUCT FLANGE 13 18" (333) 36" (914) SERVICE CLEARANCE 39 5/8" (1006) 42" (1067) 20" (508) SERVICE CLEARANCE 4 7/8" (124) 31 3/8" 36 1/4" (797) (921) 1 (25.4) 13 1/2" (343) 38 7/8" (987) 62 5/8" (1591) W.O. "C" NPTI 24 VOLT 1 1/8" (28.6) DRAIN 3/4" NPTI 46 1/2" (1181) WCI mounting location 22 3/8" (568) A 3/4" (19) HIGH VOLTAGE 7/8" (22.2) DIA. 5" (127) 15" (381) 11 1/2" (292) B W.I. "C" NPTI 1 7/8" (48) 1 5/8" (41) RETURN AIR OPENING (a) NEC requires that the GEV072-300 front return must be a non-ducted return. Table 18. GEV 6–10 tons (072-120) 60 Hz; 6 and 7½ tons (072 and 090) 50 Hz—front return/back supply Unit (60 Hz) 34 Unit (50 Hz) A B C 6 ton — 6-5/8 in. (168 mm) 18-3/8 in. (467 mm) 1-1/4 in. (32 mm) 7½ ton 6 ton 6-5/8 in. (168 mm) 18-3/8 in. (403 mm) 1-1/4 in. (32 mm) 10 ton 7½ ton 6-1/2 in. (165 mm) 18-1/2 in. (470 mm) 1-1/2 in. (38 mm) WSHP-SVX01N-EN Unit Dimensions and Weights Figure 25. GEV 6–10 tons (072–120) 60 Hz; 6 and 7½ ton (072 and 090) 50 Hz—front return/top supply(a) ACCESS PANEL FOR SHEAVES AND BELTS 1 1/8" (29) 15 5/8 (397) 13 1/4" (337) 13 3/8" (343) 36" (914) SERVICE CLEARANCE 39 5/8" (1006) 42" (1067) 1" (25.4) 20" (508) SERVICE CLEARANCE 4 7/8" (124) 31 3/8" 36 1/4" (797) (921) 63" (1600) 38 7/8" (987) W.O. "C" NPTI 24 VOLT 1 1/8" (28.6) HIGH VOLTAGE 7/8" (22.2) DIA. 5" (127) 15" (381) 22 3/8" (568) A 3/4" (19) WCI mounting location DRAIN 3/4" NPTI 1 5/8" (41) 11 1/2" (292) 62 5/8" (1591) B W.I. "C" NPTI 1 7/8" (48) SUPPLY OPENING 1" (25.4) DUCT FLANGE RETURN AIR OPENING (a) NEC requires that the GEV072-300 front return must be a non-ducted return. Table 19. GEV 6–10 tons (072-120) 60 Hz; 6 and 7½ ton (072 and 090) 50 Hz—front return/top supply Unit (60 Hz) Unit (50 Hz) A B C 6 ton — 6-5/8 in. (168 mm) 18-3/8 in. (467 mm) 1-1/4 in. (32 mm) 7½ ton 6 ton 6-5/8 in. (168 mm) 18-3/8 in. (403 mm) 1-1/4 in. (32 mm) 10 ton 7½ ton 6-1/2 in. (165 mm) 18-1/2 in. (470 mm) 1-1/2 in. (38 mm) WSHP-SVX01N-EN 35 Unit Dimensions and Weights 4 7/8" (124) Figure 26. GEV 6–10 tons (072-120) 60 Hz; 6 and 7½ ton (072 and 090) 50 Hz—back return/front supply(a) 39 5/8" (1006) ACCESS PANEL FOR SHEAVES AND BELTS 13 1/8" (333) 20" (508) SERVICE CLEARANCE 15 3/4 (400) 1 1/8" (29) 36 1/4" 31 3/8" (921) (797) 36" (914) SERVICE CLEARANCE 42" (1067) 13 1/2" (343) 1" (25.4) 38 7/8" (987) W.O. "C" NPTI 24 VOLT 1 1/8" (28.6) DRAIN 3/4" NPTI WCI mounting location 15" (381) HIGH VOLTAGE 7/8" (22.2) DIA. 5" (127) 3/4" (19) 22 3/8" (568) 62 5/8" (1591) 11 1/2" (292) A 46 1/2" (1181) B W.I. "C" NPTI 1 7/8" (48) 1 5/8" (41) RETURN AIR OPENING SUPPLY OPENING 1" (25.4) DUCT FLANGE (a) NEC requires that the GEV072-300 front return must be a non-ducted return. Table 20. GEV 6–10 tons (072-120) 60 Hz; 6 and 7½ ton (072 and 090) 50 Hz—back return/front supply Unit (60 Hz) 36 Unit (50 Hz) A B C 6 ton — 6-5/8 in. (168 mm) 18-3/8 in. (467 mm) 1-1/4 in. (32 mm) 7½ ton 6 ton 6-5/8 in. (168 mm) 18-3/8 in. (403 mm) 1-1/4 in. (32 mm) 10 ton 7½ ton 6-1/2 in. (165 mm) 18-1/2 in. (470 mm) 1-1/2 in. (38 mm) WSHP-SVX01N-EN Unit Dimensions and Weights 4 7/8" (124) Figure 27. GEV 6–10 tons (072-120) 60 Hz; 6 and 7½ ton (072 and 090) 50 Hz—back return/top supply(a) 39 5/8" (1006) ACCESS PANEL FOR SHEAVES AND BELTS 36 1/4" 31 3/8" (921) (797) 13 1/2" (343) 1 1/8" (29) 13 1/4" (337) 15 5/8 (397) 20" (508) SERVICE CLEARANCE 36" (914) SERVICE CLEARANCE 1" (25.4) 42" (1067) 38 7/8" (987) W.O. "C" NPTI 63" 24 VOLT (1600) 1 1/8" (28.6) WCI mounting location 15" (381) HIGH VOLTAGE 7/8" (22.2) DIA. A 5" (127) 3/4" (19) 22 3/8" (568) DRAIN 3/4" NPTI 11 1/2" (292) 62 5/8" (1591) B W.I. "C" NPTI 1 7/8" (48) 1 5/8" (41) RETURN AIR OPENING SUPPLY OPENING 1" (25.4) DUCT FLANGE (a) NEC requires that the GEV072-300 front return must be a non-ducted return. Table 21. GEV 6–10 tons (072-120) 60 Hz; 6 and 7½ ton (072 and 090) 50 Hz—back return/top supply Unit (60 Hz) Unit (50 Hz) A B C 1-1/4 in. (32 mm) 6 ton — 6-5/8 in. (168 mm) 18-3/8 in. (467 mm) 7½ ton 6 ton 6-5/8 in. (168 mm) 18-3/8 in. (403 mm) 1-1/4 in. (32 mm) 10 ton 7½ ton 6-1/2 in. (165 mm) 18-1/2 in. (470 mm) 1-1/2 in. (38 mm) WSHP-SVX01N-EN 37 Unit Dimensions and Weights Figure 28. GEV 12½–15 tons (150–180) 60 Hz; GEV 10 and 12½ ton (120 and 150) 50 Hz—front return/back supply(a) 31 1/2" (800) 36 1/4" (921) 10" (254) 74 1/2" (1892) 4 3/4" (121) 81 5/8" (2073) TOP VIEW 18 5/8" (473) 31 1/2" (800) 24 VOLT 1 1/8" (29) O.D. 15 7/8" (403) 38 7/8" (987) W.O. 1 1/2" (38) NPTI 67 5/8" (1718) 6 7/8" (175) DRAIN 3/4" (19) NPTI 49 1/8" (1248) WCI mounting location 20 1/2" (521) HIGH VOLTAGE 7/8" (22) O.D. 27 1/8" (537) 23 1/2 (597) 12 1/2" (318) 1" (25.4) SIDE VIEW CONTROL BOX ACCESS FRONT VIEW 2 3/8" (60) W.I. 1 1/2" (38) NPTI 2 5/8" (67) 4 1/4" (108) RETURN AIR OPENING MIN. SERVICE ON BACK FOR COMPRESSOR ACCESS IS 24” CONTROL BOX NEC REQ. UNIT FRONT 36" (914) 16" (406) TO C.B.TO WALL FILTER FRAME CLEARANCE FOR RETURN-AIR MIN. SERVICE CLEARANCE FOR EITHER LEFT OR RIGHT SIDE IS 18" (457). FOR FAN SHAFT REMOVAL, A 22" (559) CLEARANCE MUST BE PROVIDED ON EITHER THE LEFT OR RIGHT SIDE. SERVICE CLEARANCE (a) NEC requires that the GEV072-300 front return must be a non-ducted return. 38 WSHP-SVX01N-EN Unit Dimensions and Weights Figure 29. GEV 12½–15 tons (150–180) 60 Hz; GEV 10 and 12½ ton (120 and 150) 50 Hz—back return/front supply(a) 81 5/8" (2073) 4 3/4" (121) 36 1/4" (921) 74 1/2" (1892) 31 1/2" (800) 10" (254) TOP VIEW 18 5/8" (473) 31 1/2" (800) 15 7/8" (403) 38 7/8" (987) W.O. 1 1/2" (38) NPTI 1" (25.4) 24 VOLT 1 1/8" (29) O.D. WCI mounting location DRAIN 3/4" (19) NPTI 49 1/8" (1248) 20 1/2" 2 (521) 27 1/8" (537) 6 7/8" (175) 67 5/8" (1718) HIGH VOLTAGE 7/8" (22) O.D. CONTROL BOX ACCESS 12 1/2" (318) W.I. 1 1/2" (38) NPTI FRONT VIEW 2 5/8" (67) 4 1/4" (108) 2 3/8" (60) SIDE VIEW 23 1/2 (597) RETURN AIR OPENING MIN. SERVICE ON BACK FOR COMPRESSOR ACCESS IS 24” CONTROL BOX NEC REQ. UNIT FRONT 36" (914) 16" (406) TO C.B.TO WALL FILTER FRAME CLEARANCE FOR RETURN-AIR MIN. SERVICE CLEARANCE FOR EITHER LEFT OR RIGHT SIDE IS 18" (457). FOR FAN SHAFT REMOVAL, A 22" (559) CLEARANCE MUST BE PROVIDED ON EITHER THE LEFT OR RIGHT SIDE. SERVICE CLEARANCE (a) NEC requires that the GEV072-300 front return must be a non-ducted return. WSHP-SVX01N-EN 39 Unit Dimensions and Weights Figure 30. GEV 12½–15 tons (150-180) 60 Hz; GEV 10 and 12½ ton (120 and 150) 50 Hz—front return/top supply(a) 15 7/8" (403) 31 1/2" (800) 36 1/4" (921) 10" (254) 14 3/8" (365) 74 1/2" (1892) 4 3/4" (121) 81 5/8" (2073) TOP VIEW 18 5/8" (473) 31 1/2" (800) 38 7/8" (987) (98 W.O. 1 1/2" (38) NPTI WCI mounting location 20 1/2" (521) 24 VOLT 1 1/8" (29) O.D. 6 7/8" (175) 68" (1727) HIGH VOLTAGE 7/8" (22) O.D. CONTROL BOX ACCESS 27 1 1/8" (53 (537) 12 1/2" (318) 1" (25.4) SIDE VIEW DRAIN 3/4" (19) NPTI FRONT VIEW W.I. 1 1/2" (38) NPTI 23 1/2 (597) 2 5/8" (67) 4 1/4" (108) 2 3/8" (60) SUPPLY OPENING WITH 1" (25.4) DUCT FLANGE MIN. SERVICE ON BACK FOR COMPRESSOR ACCESS IS 24” CONTROL BOX NEC REQ. UNIT FRONT 36" (914) 16" (406) TO C.B.TO WALL FILTER FRAME CLEARANCE FOR RETURN-AIR MIN. SERVICE CLEARANCE FOR EITHER LEFT OR RIGHT SIDE IS 18" (457). FOR FAN SHAFT REMOVAL, A 22" (559) CLEARANCE MUST BE PROVIDED ON EITHER THE LEFT OR RIGHT SIDE. RETURN AIR OPENING SERVICE CLEARANCE (a) NEC requires that the GEV072-300 front return must be a non-ducted return. 40 WSHP-SVX01N-EN Unit Dimensions and Weights Figure 31. GEV 12½–15 ton (150–180) 60 Hz; GEV 10 and 12½ ton (120 and 150) 50 Hz—back return/top supply(a) 81 5/8" (2073) 4 3/4" (121) 74 1/2" (1892) 14 3/8" (365) 36 1/4" (921) 31 1/2" (800) 10" (254) 15 7/8 7/8" (403 (403) TOP VIEW 18 5/8" (473) 31 1/2" (800) 38 7/8" (987) W.O. 1 1/2" (38) NPTI 68" (1727) 1" (25.4) 6 7/8" (175) 24 VOLT 1 1/8" WCI mounting (29) O.D. location HIGH VOLTAGE 7/8" (22) O.D. SIDE VIEW CONTROL BOX ACCESS 20 1/2" 2 (521) 7 1/8" 27 (537) DRAIN 3/4" (19) NPTI 12 1/2" (318) FRONT VIEW W.I. 1 1/2" (38) NPTI 23 1/2 (597) 2 5/8" (67) 4 1/4" (108) 2 3/8" (60) RETURN AIR OPENING SUPPLY OPENING WITH 1" (25.4) DUCT FLANGE MIN. SERVICE ON BACK FOR COMPRESSOR ACCESS IS 24” CONTROL BOX NEC REQ. UNIT FRONT 36" (914) 16" (406) TO C.B.TO WALL FILTER FRAME CLEARANCE FOR RETURN-AIR MIN. SERVICE CLEARANCE FOR EITHER LEFT OR RIGHT SIDE IS 18" (457). FOR FAN SHAFT REMOVAL, A 22" (559) CLEARANCE MUST BE PROVIDED ON EITHER THE LEFT OR RIGHT SIDE. SERVICE CLEARANCE (a) NEC requires that the GEV072-300 front return must be a non-ducted return. WSHP-SVX01N-EN 41 Unit Dimensions and Weights Figure 32. GEV 20 and 25 ton (240 and 300) 60 Hz; GEV 15 and 20 ton (180 and 240) 50 Hz—front return/back supply(a) 31 1/2" (800) 36 1/4" (921) 6 1/4" (159) 74 1/2" (1892) 4 3/4" (121) 81 5/8" (2073) TOP VIEW C 19 1/8" (486) A A 24 VOLT 1 1/8" (29) O.D. B 38 7/8" (987) W.O. 2" (51) NPTI 67 5/8" (1718) 6 7/8" (175) DRAIN 3/4" (19) NPTI D WCI mounting location CONTROL BOX ACCESS 27 1/8" (537) 20 1/2" (521) E 12 1/2" (318) HIGH VOLTAGE 7/8" (22) O.D. 1" (25.4) FRONT VIEW W.I. 2" (51) NPTI 2 5/8" (67) 4 1/4" (108) 2 3/8" (60) SIDE VIEW MIN. SERVICE ON BACK FOR COMPRESSOR ACCESS IS 24” RETURN AIR OPENING CONTROL BOX NEC REQ. UNIT FRONT 36" (914) 16" (406) TO C.B.TO WALL FILTER FRAME CLEARANCE FOR RETURN-AIR MIN. SERVICE CLEARANCE FOR EITHER LEFT OR RIGHT SIDE IS 18" (457). FOR FAN SHAFT REMOVAL, A 22" (559) CLEARANCE MUST BE PROVIDED ON EITHER THE LEFT OR RIGHT SIDE. SERVICE CLEARANCE (a) NEC requires that the GEV072-300 front return must be a non-ducted return. Table 22. GEV 20 and 25 ton (240 and 300) 60 Hz; GEV 15 and 20 ton (180 and 240) 50 Hz—front return/back supply Unit (60 Hz) 42 Unit (50 Hz) A B C D E 20 ton 15 ton 15-5/8 in. (397 mm) 13-1/2 in. (341 mm) 12 in. (305 mm) 51-5/8 in. (1310 mm) 20-7/8 in. (530 mm) 25 ton Std Static 20 ton Std Static 14-3/4 in. (375 mm) 15-7/8 in. (403 mm) 13-7/8 in. (352 mm) 49-1/8 in. (1248 mm) 23-1/2 in. (597 mm) 25 ton High Static 20 ton High Static 15-5/8 in. (397 mm) 13-1/2 in. (343 mm) 12 in. (305 mm) 51-5/8 in. (1311 mm) 23-1/2 in. (597 mm) WSHP-SVX01N-EN Unit Dimensions and Weights Figure 33. GEV 20 and 25 ton (240 and 300) 60 Hz; GEV 15 and 20 ton (180 and 240) 50 Hz - back return/front supply(a) 81 5/8" (2073) 4 3/4" (121) 36 1/4" (921) 74 1/2" (1892) 31 1/2" (800) 6 1/4" (159) TOP VIEW C 19 1/8" (486) A A B 38 7/8" (987) W.O. 2" (51) NPTI 27 1/8" 537) (537) 1" (25.4) 24 VOLT 1 1/8" WCI mounting (29) O.D. location 6 7/8" (175) 6 5/8" 67 ( (1718) DRAIN 3/4" (19) NPTI D CONTROL BOX ACCESS 20 1/2" (521) E 12 1/2" (318) HIGH VOLTAGE 7/8" (22) O.D. W.I. 2" (51) NPTI FRONT VIEW 2 5/8" (67) 4 1/4" (108) 2 3/8" (60) SIDE VIEW RETURN AIR OPENING MIN. SERVICE ON BACK FOR COMPRESSOR ACCESS IS 24” CONTROL BOX NEC REQ. UNIT FRONT 36" (914) 16" (406) TO C.B.TO WALL FILTER FRAME CLEARANCE FOR RETURN-AIR MIN. SERVICE CLEARANCE FOR EITHER LEFT OR RIGHT SIDE IS 18" (457). FOR FAN SHAFT REMOVAL, A 22" (559) CLEARANCE MUST BE PROVIDED ON EITHER THE LEFT OR RIGHT SIDE. SERVICE CLEARANCE (a) NEC requires that the GEV072-300 front return must be a non-ducted return. Table 23. GEV 20 and 25 ton (240 and 300) 60 Hz; GEV 15 and 20 ton (180 and 240) 50 Hz—back return/front supply Unit (60 Hz) Unit (50 Hz) A B C D E 20 ton 15 ton 15-5/8 in. (397 mm) 13-1/2 in. (341 mm) 12 in. (305 mm) 51-5/8 in. (1310 mm) 20-7/8 in. (530 mm) 25 ton Std Static 20 ton Std Static 14-3/4 in. (375 mm) 15-7/8 in. (403 mm) 13-7/8 in. (352 mm) 49-1/8 in. (1248 mm) 23-1/2 in. (597 mm) 25 ton High Static 20 ton High Static 15-5/8 in. (397 mm) 13-1/2 in. (343 mm) 12 in. (305 mm) 51-5/8 in. (1311 mm) 23-1/2 in. (597 mm) WSHP-SVX01N-EN 43 Unit Dimensions and Weights Figure 34. GEV 20 and 25 ton (240 and 300) 60 Hz; GEV 15 and 20 ton (180 and 240) 50 Hz—front return/top supply(a) 6 1/4" (159) 1 1/4" (32) B 31 1/2" (800) 36 1/4" (921) 74 1/2" (1892) 4 3/4" (121) 81 5/8" (2073) TOP VIEW C 19 1/8" (486) A A 38 7/8" (987) (98 W.O. 2" (51) NPTI WCI mounting location 20 1/2" (521) 24 VOLT 1 1/8" (29) O.D. 6 7/8" (175) 68" (1727) HIGH VOLTAGE 7/8" (22) O.D. CONTROL BOX ACCESS 1/8" 27 1 (537) (53 D 12 1/2" (318) 1" (25.4) SIDE VIEW DRAIN 3/4" (19) NPTI FRONT VIEW W.I. 2" (51) NPTI MIN. SERVICE ON BACK FOR COMPRESSOR ACCESS IS 24” CONTROL BOX NEC REQ. UNIT FRONT 36" (914) 16" (406) TO C.B.TO WALL FILTER FRAME CLEARANCE FOR RETURN-AIR 2 5/8" (67) 4 1/4" (108) 2 3/8" (60) SUPPLY OPENINGS WITH 1" (25.4) DUCT FLANGE MIN. SERVICE CLEARANCE FOR EITHER LEFT OR RIGHT SIDE IS 18" (457). FOR FAN SHAFT REMOVAL, A 22" (559) CLEARANCE MUST BE PROVIDED ON EITHER THE LEFT OR RIGHT SIDE. RETURN AIR OPENING SERVICE CLEARANCE (a) NEC requires that the GEV072-300 front return must be a non-ducted return. Table 24. GEV 20 and 25 ton (240 and 300) 60 Hz; GEV 15 and 20 ton (180 and 240) 50 Hz—front return/top supply Unit (60 Hz) 44 Unit (50 Hz) A B C D 20 ton 15 ton 15-5/8 in. (397 mm) 13-1/2 in. (341 mm) 12 in. (305 mm) 20-7/8 in. (530 mm) 25 ton Std Static 20 ton Std Static 14-3/4 in. (375 mm) 15-7/8 in. (403 mm) 13-7/8 in. (352 mm) 23-1/2 in. (597 mm) 25 ton High Static 20 ton High Static 15-5/8 in. (397 mm) 13-1/2 in. (343 mm) 12 in. (305 mm) 23-1/2 in. (597 mm) WSHP-SVX01N-EN Unit Dimensions and Weights Figure 35. GEV 20 and 25 ton (240 and 300) 60 Hz; GEV 15 and 20 ton (180 and 240) 50 Hz—back return/top supply(a) 81 5/8" (2073) 4 3/4" (121) 1 1/4 1/4" (32) 36 1/4" (921) 74 1/2" (1892) 31 1/2" (800) B 6 1/4" (159) TOP VIEW C 19 1/8" (486) A A 38 7/8" (987) W.O. 2" (51) NPTI 68" (172 (1727) 1" (25.4) 6 7/8" (175) 24 VOLT 1 1/8" (29) O.D. WCI mounting location CONTROL BOX ACCESS 20 1/2" (521) 27 1/8" (537) DRAIN 3/4" (19) NPTI HIGH VOLTAGE 7/8" (22) O.D. SIDE VIEW MIN. SERVICE ON BACK FOR COMPRESSOR ACCESS IS 24” CONTROL BOX NEC REQ. UNIT FRONT 36" (914) 16" (406) TO C.B.TO WALL FILTER FRAME CLEARANCE FOR RETURN-AIR D 12 1/2" (318) FRONT VIEW W.I. 2" (51) NPTI 2 5/8" (67) 4 1/4" (108) 2 3/8" (60) RETURN AIR OPENING SUPPLY OPENING WITH 1" (25.4) DUCT FLANGE MIN. SERVICE CLEARANCE FOR EITHER LEFT OR RIGHT SIDE IS 18" (457). FOR FAN SHAFT REMOVAL, A 22" (559) CLEARANCE MUST BE PROVIDED ON EITHER THE LEFT OR RIGHT SIDE. SERVICE CLEARANCE (a) NEC requires GEV072-300 front return must be non-ducted return. Table 25. GEV 20 and 25 ton (240 and 300) 60 Hz; GEV 15 and 20 ton (180 and 240) 50 Hz—back return/top supply Unit (60 Hz) Unit (50 Hz) A B C D 12 in. (305 mm) 20-7/8 in. (530 mm) 20 ton 15 ton 15-5/8 in. (397 mm) 13-1/2 in. (341 mm) 25 ton Std Static 20 ton Std Static 14-3/4 in. (375 mm) 15-7/8 in. (403 mm) 13-7/8 in. (352 mm) 23-1/2 in. (597 mm) 25 ton High Static 20 ton High Static 15-5/8 in. (397 mm) 13-1/2 in. (343 mm) 12 in. (305 mm) 23-1/2 in. (597 mm) WSHP-SVX01N-EN 45 Unit Dimensions and Weights 5/8" (16) 1 1/2" (38) Figure 36. GEH and EXH waterside economizer(a) G N TOP VIEW 5/8"(16) M H 20" (508) A = TO FIELD SUPPLY PIPING E 5" (127) J 2 1/2" (64) L K FRONT VIEW D C F B = TO FIELD RETURN PIPING (a) Waterside economizer installation requires field piping. Table 26. GEH and EXH waterside economizer GEH GEH (60 Hz) (50 Hz) A NPTI B NPTI C D E F G H J K L M N 1/2 (12.7) 16-1/8 (410) 13-5/8 (346) 1-1/2 (38) 10-3/4 (273) 23 (584) 2-1/4 (57) 7-1/2 (191) 1/2 (12.7) 1 (25.4) 4 (102) 18-1/2 (470) 006-015 006-012 1/2 (12.7) 018-030 015-024 3/4 (19) 3/4 (19) 18-1/2 (470) 15-5/8 (397) 1-1/2 (38) 13-3/4 (349) 26 (660) 3-1/4 (83) 6-7/8 (175) 1/2 (12.7) 1 (25.4) 4 (102) 18-1/2 (470) 036-042 030-036 3/4 (19) 3/4 (19) 21 (533) 17-5/8 (448) 2-1/4 (57) 16-1/2 (419) 30 (762) 3-3/4 (95) 6-1/4 (159) 1-1/4 (32) 2 (50.8) 4-1/2 (114) 23-1/2 (597) 048-060 042-060 1 (25.4) 1 (25.4) 23-1/8 (587) 19-5/8 (498) 2-1/2 (64) 19-1/2 (495) 34 (864) 5-1/4 (133) 5-7/8 (149) 1-1/4 (32) 2 (50.8) 4-1/2 (114) 23-1/2 (597) EXH GEH (60 Hz) (50 Hz) A NPTI B NPTI C D E F G H J K L M N 006-015 ---- 1/2 (12.7) 1/2 (12.7) 16-1/8 (410) 13-5/8 (346) 1-1/2 (38) 10-3/4 (273) 23 (584) 2-1/4 (57) 7-1/2 (191) 1/2 (12.7) 1 (25.4) 4 (102) 18-1/2 (470) 018-024 ---- 3/4 (19) 3/4 (19) 18-1/2 (470) 15-5/8 (397) 1-1/2 (38) 13-3/4 (349) 26 (660) 3-1/4 (83) 6-7/8 (175) 1/2 (12.7) 1 (25.4) 4 (102) 18-1/2 (470) 030-036 ---- 3/4 (19) 3/4 (19) 21 (533) 17-5/8 (448) 2-1/4 (57) 16-1/2 (419) 30 (762) 3-3/4 (95) 6-1/4 (159) 1-1/4 (32) 2 (50.8) 4-1/2 (114) 23-1/2 (597) 042-070 ---- 1 (25.4) 1 (25.4) 23-1/8 (587) 19-5/8 (498) 2-1/2 (64) 19-1/2 (495) 34 (864) 5-1/4 (133) 5-7/8 (149) 1-1/4 (32) 2 (50.8) 4-1/2 (114) 23-1/2 (597) 46 WSHP-SVX01N-EN Unit Dimensions and Weights Figure 37. GEH and EXH hanging unit waterside economizer Table 27. GEH and EXH hanging unit waterside economizer GEH Unit (60 Hz) GEH Unit (50 Hz) 006-015 006-012 018-030 015-024 036-042 030-036 048-060 042-048 EXH Unit (60 Hz) EXH Unit (50 Hz) 006-015 — 018-024 — 030-036 — 042-070 — A B C D E Hanging Weight Shipping Weight 38-3/4 (984) 44-3/4 (1137) 48-3/4 (1238) 56-3/4 (1441) 18-3/4 (476) 21-3/4 (552) 23-3/4 (603) 31-3/4 (806) 21-3/4 (552) 24-3/4 (629) 28-3/4 (730) 32-3/4 (832) 17 (432) 21 (553) 21 (533) 25 (635) 0 (0) 1 (25) 2 (51) 1 (25) 54 lbs (25 kg) 65 lbs (30 kg) 76 lbs (35 kg) 97 lbs (44 kg) 84 lbs (38 kg) 95 lbs (43 kg) 106 lbs (48 kg) 127 lbs (58 kg) A B C D E Hanging Weight Shipping Weight 38-3/4 (984) 44-3/4 (1137) 48-3/4 (1238) 56-3/4 (1441) 18-3/4 (476) 21-3/4 (552) 23-3/4 (603) 31-3/4 (806) 21-3/4 (552) 24-3/4 (629) 28-3/4 (730) 32-3/4 (832) 17 (432) 21 (553) 21 (533) 25 (635) 0 (0) 1 (25) 2 (51) 1 (25) 54 lbs (25 kg) 65 lbs (30 kg) 76 lbs (35 kg) 97 lbs (44 kg) 84 lbs (38 kg) 95 lbs (43 kg) 106 lbs (48 kg) 127 lbs (58 kg) Note: All dimensions are in inches followed by millimeters in parenthesis. WSHP-SVX01N-EN 47 Unit Dimensions and Weights Figure 38. GEH 6-10 tons (072-120) 60 Hz, right return; GEH 6-7½ tons (072-090) 50 Hz, right return, waterside economizer(a)(b) 9 7/8" (251) 18 1/2" (470) 50 5/8" (1286) 36" (914) 2 1/8" (54) 23 7/8" (606) C "B" OD COPPER TO FIELD SUPPLY PIPING "A" NPTI FOR FIELD RETURN PIPING D E (a) Entering water is on the AB port. (b) Field piping required on waterside economizer. 48 WSHP-SVX01N-EN Unit Dimensions and Weights Figure 39. GEH 6-10 tons (072-120) 60 Hz, left return; GEH 6-7½ tons (072-090) 50 Hz, left return, waterside economizer(a)(b) 9 7/8" (251) 18 1/2" (470) 50 5/8" (1286) 36" (914) 1 1/4" (32) 24 3/4" (629) C "B" OD COPPER TO FIELD SUPPLY PIPING "A" NPTI FOR FIELD RETURN PIPING D E (a) Entering water is on the AB port. (b) Field piping required on waterside economizer. Table 28. GEH 6-10 tons (072-120) 60 Hz, left return; GEH 6-7½ tons (072-090) 50 Hz, left return, waterside economizer GEH (60 Hz) GEH (50 Hz) 072 — 090 072 120 090 C Hanging Shipping Weight Weight A B D E 1-1/4 1-3/8 (32) (35) 31 9-7/8 3-7/8 138 lbs 168 lbs (787) (251) (98) (63 kg) (76 kg) 1-1/4 1-3/8 (32) (35) 31 9-7/8 3-7/8 144 lbs 174 lbs (787) (251) (98) (65 kg) (79 kg) 1-1/2 1-5/8 30-3/4 12-1/2 4-1/2 166 lbs 196 lbs (38) (41) (781) (318) (114) (75 kg) (89 kg) Note: All dimensions are in inches followed by millimeters in parenthesis. WSHP-SVX01N-EN 49 Unit Dimensions and Weights Figure 40. GEH 12½-15 tons (150-180) 60 Hz, right return; GEH 10-12½ tons (120-150) 50 Hz, right return, waterside economizer(a)(b) 9 7/8" (251) 18 1/2" (470) 56 1/2" (1435) 42" (1067) 2 1/4" (57) 29 3/4" (756) 48 3/4" (1238) 1 5/8" (42) OD COPPER TO FIELD SUPPLY PIPING 1 1/2" (38) NPTI FOR FIELD RETURN PIPING 12" (305) 5 3/8" (137) (a) Entering water is on the AB port. (b) Field piping required on waterside economizer. Table 29. GEH 12½-15 tons (150-180) 60 Hz, right return; GEH 10-12½ tons (120-150) 50 Hz, right return, waterside economizer GEH (60 Hz) GEH (50 Hz) 150 120 180 150 Hanging Weight Shipping Weight 138 lbs 168 lbs (63 kg) (76 kg) 144 lbs 174 lbs (65 kg) (79 kg) Note: All dimensions are in inches followed by millimeters in parenthesis. Table 30. GEH 12½-15 tons (150-180) 60 Hz, right return; GEH 10-12½ tons (120-150) 50 Hz, left return, waterside economizer GEH (60 Hz) 150 - 180 GEH (50 Hz) 120-150 Hanging Weight Shipping Weight 213 lbs 243 lbs (97 kg) (110 kg) Note: All dimensions are in inches followed by millimeters in parenthesis. 50 WSHP-SVX01N-EN Unit Dimensions and Weights Figure 41. GEH 12½-15 tons (150-180) 60 Hz, left return; GEH 10-12½ tons (120-150) 50 Hz, left return, waterside economizer(a)(b) 9 7/8" (251) 18 1/2" (470) 56 1/2" (1435) 42" (1067) 2 1/4" (57) 29 3/4" (756) 1 5/8" (42) OD COPPER TO FIELD SUPPLY PIPING 27 1/8" (689) 1 1/2" (38) NPTI FOR FIELD RETURN PIPING 12" (305) 5 3/8" (137) (a) Entering water is on the AB port. (b) Field piping required on waterside economizer. WSHP-SVX01N-EN 51 Unit Dimensions and Weights Figure 42. GEV 6-10 tons (072-120) 60 Hz; 6 and 7½ ton (072 and 090) 50 Hz, waterside economizer(a) (a) Entering water is on the AB port. Table 31. GEV 6-10 tons (072-120) 60 Hz; 6 and 7½ ton (072 and 090) 50 Hz, waterside economizer Unit (60 Hz) Unit (50 Hz) 072 — 090 072 120 090 C Hanging Weight Shipping Weight A B 1-1/4 1-3/8 4 148 lbs 178 lbs (32) (35) (102) (67 kg) (81 kg) 1-1/4 1-1/4 4 168 lbs 198 lbs (32) (32) (102) (76 kg) (90 kg) 1-1/2 1-5/8 4-3/8 207 lbs 237 lbs (38) (41) (111) (94 kg) (108 kg) Note: All dimensions are in inches followed by millimeters in parenthesis. 52 WSHP-SVX01N-EN Unit Dimensions and Weights Figure 43. GEV 12½-25 tons (150-300), waterside economizer(a) (a) Entering water is on the AB port. Table 32. GEV 12½-25 tons (150-300), waterside economizer GEV (60 Hz) GEV (50 Hz) 150-180 120-150 240 180 300 240 A NPTI B I.D. C D 1-1/2 1-5/8 15-7/8 4-3/8 275 lbs 305 lbs (38) (41) (403) (111) (125 kg) (138 kg) Hanging Weight Shipping Weight 2 2-1/8 16-1/4 4-7/8 310 lbs 340 lbs (51) (54) (413) (124) (141 kg) (154 kg) 2 2-1/8 16-1/4 4-7/8 395 lbs 425 lbs (51) (54) (413) (124) (179 kg) (193 kg) Note: All dimensions are in inches followed by millimeters in parenthesis. Table 33. Unit weights GEH ½-5 ton (60 Hz) GEH 006 009 012 015 018 024 030 036 042 048 Net Weight (lbs.) 165 165 173 173 248 253 253 288 288 398 060 398 Ship Weight (lbs.) 195 195 203 203 268 285 285 318 318 428 428 Table 34. Unit weights GEV ½-5 ton (60 Hz) Model GEV 006 009 012 015 018 024 030 036 042 048 060 Net Weight (lbs.) 165 165 173 173 248 253 253 288 288 348 349 Ship Weight (lbs.) 195 195 203 203 268 285 285 308 308 396 396 WSHP-SVX01N-EN 53 Unit Dimensions and Weights Figure 44. Waterside economizer coil piping diagram Note: (applicable only to 6 to 25 ton models) Unit Water Outlet Unit Heat Exchanger WSE Coil Outlet Unit Water Inlet WSE Coil Inlet WSE Coil TEE Port A Port AB 3 Way Valve Please match the entering water port marking with the marking label on the valve prior to using this diagram. 54 Port B Entering Water WSHP-SVX01N-EN Unit Dimensions and Weights Table 35. Figure 45. Weight distribution ½-6 ton GEH/EXH Unit weights EXV ½-6 ton EXV (60 Hz) Shipping Weight with pallet (lbs) Unit Weight without pallet (lbs) 006 195 165 009 195 165 012 203 173 015 203 173 018 284 264 024 301 269 030 319 299 036 333 313 042 402 381 048 422 374 060 442 394 070 482 434 Figure 46. Weight distribution GEH 6-15 ton Table 36. Unit weights EXH ½-6 ton EXH (60 Hz) Shipping Weight with pallet (lbs) Unit Weight without pallet (lbs) 006 195 165 009 195 165 012 203 173 015 203 173 018 284 264 024 301 269 030 329 299 036 343 313 042 461 431 048 454 424 060 474 444 070 514 484 Weight Distribution for Hanging the GEH and EXH Model WARNING Improper Unit Lift! Test lift unit approximately 24 inches to verify proper center of gravity lift point. To avoid dropping of unit, reposition lifting point if unit is not level. Failure to properly lift unit could result in death or serious injury or possible equipment or property-only damage. Approximate weight distribution for proper hanging of the GEH and EXH unit is indicated by weight distribution ½-6 ton GEH/EXH Figure 45, p. 55. Tolerance on the weights determined are ±15%. Total weights for each unit size are listed in Table 33, p. 53,Table 34, p. 53 and Table 35, p. 55. WSHP-SVX01N-EN 55 Installation Main Electrical WARNING Proper Field Wiring and Grounding Required! All field wiring MUST be performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field wiring installation and grounding as described in NEC and your local/state electrical codes. Failure to follow codes could result in death or serious injury. General Installation Checks The checklist below is a summary of the steps required to successfully install a commercial unit.This checklist is intended to acquaint the installing personnel with what is required in the installation process. It does not replace the detailed instructions that are in the applicable sections of this manual. 1. Remove packaging and inspect the unit. Check the unit for shipping damage and material shortage; file a freight claim and notify appropriate sales representation. The GEH/V ½-5 ton and EXH/V ½-6 ton units have been anchored to the skid by (2) shipping bolts.The removal of these bolts will require a 3/8 (9.7 mm) ratchet with a ½ (12.7 mm) socket. The GEV 6–25 ton units have been anchored to the skid with (4) angle brackets. Remove these brackets before lifting unit into place. The GEH 6–15 ton units are anchored to the cross brace of the skid with (4) wood screws. Remove these screws prior to lifting the unit into place. 2. Verify the correct model, options and voltage from the unit nameplate. 3. Pull out all field attached parts (i.e. filter rack, duct collar, filter and mounting screws) from the unit packaging for field mounting. 4. Verify the installation location of the unit will provide the required clearance for proper operation. 5. Remove refrigeration access panel and inspect the unit. Be certain the refrigerant tubing has clearance from adjacent parts. 6. Fabricate and install duct work 7. Install and connect a condensate drain line and trap to the drain connection. WARNING Hazardous Voltage! Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/ tagout procedures to ensure the power can not be inadvertently energized. Failure to disconnect power before servicing could result in death or serious injury. 1. Verify the power supply complies with the unit nameplate specifications. 2. Inspect all control panel components; tighten any loose connections. 3. Connect properly sized and protected power supply wiring to a field-supplied/installed disconnect switch and to the main compressor contactor/power block 1K1 (compressor contactor on the ½-5 ton) for GEH/V ½-5 ton and EXH/V ½-6 ton units or 1TB1 for GEH/V 625 ton equipment in the unit control panel. 4. Install proper grounding wires to an earth ground. EXH and EXV 460 V units require a neutral (a four wire system). Note: All field-installed wiring must comply with NEC and applicable local codes. Electric Heat Requirements 5. Verify that the power supply complies with the electric heater specifications on the unit and heater nameplate. 6. Inspect the heater junction box and control panel; tighten any loose connections. 7. Check electric heat circuits for continuity. Low Voltage Wiring Requirements 8. Install the zone sensor or thermostat. 9. Connect properly sized control wiring to the proper termination points between the zone sensor or thermostat and the unit control panel. Filter Installation Each unit ships with 1"(25.4 mm) or 2"(50.8 mm) throwaway filters. 2" MERV 8 or 2" MERV 13 filters are also available options.The quantity of filters is determined by unit size.The GEH 1/2-5 ton and EXH units require field installation of the 1" or 2" ducted filters rack. All sheet metal bracket, filter and hardware are in a box located on the side of the unit within the unit packaging. All ½-25 ton verticals and GEH 6–15 ton horizontal units ship with the filter rack and filters factory installed. Note: Do not operate the unit without filters. 56 WSHP-SVX01N-EN Installation Supply-Air Ductwork Figure 48. Flexible return-air connector (field provided) Horizontal ½-5 ton and EXHF units require duct flanges to be field installed.The duct flange ships in a box on the side of the unit. Install the flange with (8) 3/8 in. (213 mm) factory supplied screws. SUPPLY-AIR Install the 1 in. (25.4 mm) supply-air duct flange to the vertical and horizontal equipment with the (8) 5/16 in. (7.94 mm) factory-supplied screws.The duct collar assembly for each unit is shipped with the unit in the same box where the IOM manual is located. RETURN AIR When attaching the field ductwork to the unit, provide a watertight flexible connector at the unit to prevent operating sounds from transmitting through the ductwork. See Figure 47, p. 57. RETURN-AIR BOOT (FIELD PROVIDED) DUCT COLLAR (FACTORY PROVIDED) Elbows with turning vanes or splitters are recommended to minimize air noise due to turbulence and to reduce static pressure. Figure 47. Flexible supply-air connector (field provided) SUPPLY-AIR BOOT (FIELD SUPPLIED) 1-INCH DUCT COLLAR (FACTORY PROVIDED) Ducted Panel The return-air arrangement may be easily converted from a free return-air system, to a ducted return-air system with the addition of a return-air side panel. By replacing the filter racks with the return-air panel, a complete seal from the duct to the unit is possible.The 1½ duct flange facilitates ease of field connection to the duct system.This accessory is typically used when the return-air filter is placed in a built-in ceiling grille, or placed within a field provided filter rack assembly. Figure 49. Return-air duct panel Return-Air Ductwork Install the 1”-2” (25.4 mm/50.8 mm) adjustable filter rack to the horizontal equipment only with the use of (4) 5/16 in. (7.94 mm) factory supplied screws.The vertical equipment factory ships with the filter rack and filter(s) installed. When attaching the field ductwork to the unit, provide a water-tight flexible connector at the unit to prevent operating sounds from transmitting through the ductwork. Elbows with turning vanes or splitters are recommended to minimize air noise due to turbulence and to reduce static pressure. Table 37. WSHP-SVX01N-EN Opening size and part number GEH Unit Size (60 Hz) Unit Size (50 Hz) 006-015 006-012 17½ in. 13 in. (445 mm) (330 mm) 4474 1133 0100 018-030 015-024 20½ in. 16 in. (521 mm) (406 mm) 4474 5628 0100 036-042 030-036 22½ in. 17 in. (432 (572 mm) mm) 4474 1135 0100 048-060 042-060 26½ in. 19 in. (483 (673 mm) mm) 4474 1136 0100 A B Duct Collar Part Number 57 Installation Table 39. Ducted filter opening size Figure 50. Install return-air duct panel 1" Unit Top op it T Unit Side Un Install the returnair duct panel to the return-air opening with the six screws provided for the filter rack assembly. A 3 3/4" Unit Side B B (in.) C (in.) 30.7 26.6 5.5 EXH 006-015 21.1 15.4 5.4 EXH 018-030 24.5 18.4 5.6 EXH 036-042 26.4 19.4 5.5 EXH 048-070 30.7 21.4 5.5 EXV 006-015 20.7 17.1 5.5 EXV 018-030 20.7 23.1 5.5 EXV 036-042 25.7 22.4 4.3 EXV 048-070 30.7 26.6 5.5 Dual Filtration (GEH ½-5 ton and EXH ½-6 ton) Note: The dual-filtration design is typically used in a freereturn application. Opening size and part number EXH EXH (60 hz) A (in.) B (in.) Duct Collar Part Number 006-015 17-1/2 13 447411330100 018-024 20-1/2 16 447456280100 030-036 22-1/2 17 447411350100 042-070 26-1/2 19 447411360100 Ducted Filter Rack The horizontal, GEH and EXH model, allows the installer flexibility in design applications such as a dual filtration option.With the dual filtration design, the unit will contain a lower static which translates into a decrease in filter maintenance. For installation of a dual filtration accessory for the GEH and EXH model, verify that an extra set of return-air filter racks and filter have been ordered from the factory.This accessory will be shipped separate from the unit, and should be located in a separate box than the unit. 1. Remove the return-air side panel from the GEH and EXH unit.This panel is held in place by screws. When it is necessary to have filter access at the unit in a ducted return, a ducted filter rack is available.This option allows access to the filter at the unit. Vertical unit filter racks are available in right or left access configurations. Horizontal units are available in top, bottom or side access configurations. Figure 51. Table 39. Ducted filter opening size Unit Size A (in.) B (in.) C (in.) GEH 006-015 21.1 15.4 5.4 GEH 018-030 24.5 18.4 5.6 GEH 036-042 26.4 19.4 5.5 GEH 048-060 30.7 21.4 5.5 GEV 006-015 20.7 17.1 5.5 GEV 018-030 20.7 23.1 5.5 GEV 036-042 25.7 22.4 4.3 58 A (in.) Note: All dimensions in inches DUCT PANEL with 1 1/2"-FLANGE Table 38. Unit Size GEV 048-060 Side panel 2. Install the top/bottom filter rack at the new opening. The adjustable filter rack is held in place with four screws that once held the panel. WSHP-SVX01N-EN Installation Figure 52. Install top/bottom filter rack 3. Slope horizontal units in two directions.The unit should contain a dual ¼-12 pitch toward the drain connection.This will insure proper drainage of the unit. All plumbing to the unit should conform per national and local codes and is the responsibility of the contractor. Figure 54. Hanging the unit 3. Install the 1”or 2”(25.4 mm/50.8 mm) filter. RETURN-AIR SUPPLY-AIR Figure 53. Install filter 3/8" ALL-THREAD (BY OTHERS) 3/8" WASHER / NUT (BY OTHERS) Condensate Drain Connection Figure 55. Negative pressure system Sound Attenuation Pad For sound-sensitive installations, a vibration pad (field provided) should be placed beneath the horizontal or vertical equipment. For the horizontal unit, the pad should be approximately twice the size of the unit foot print. For the vertical unit, the pad should be ½ in. (12.7 mm) thick, and equal to the overall unit foot print. Hanging the Horizontal Unit WARNING Risk of Unit Dropping! You MUST mount the unit to an area of the ceiling strong enough to support the weight of that unit. If unsure, you MUST confirm with a structural engineer. Failure to do so could result in unit dropping from the ceiling which could result in death or serious injury, and equipment damage. To hang the horizontal configuration (see Figure 54, p. 59): 1. Install the hanging isolators (located in the return-air section of the unit) into the four hanging brackets. 2. Secure the equipment to a joist, concrete, etc. with the use of 3/8 in. (9.7 mm) field provided (all-thread) rod. Each corner should contain field provided nuts and washers to complete the hanging installation. WSHP-SVX01N-EN Install proper trapping to the equipment.The unit drain connection is ¾ in. NPT for all GEV ½-25 ton and GEH ½5 ton and EXH/V ½-6 ton models. For 6-15 ton GEH models, the drain connection is ½ in. PVC schedule 40 pipe. When designing the condensate trap for the water-source system, it is important to consider the unit draw-thru design requiring negative pressure trapping. In a properly trapped system, when condensate forms during normal operation, the water level in the trap rises until there is a constant flow. It is imperative to maintain water in the trap and not allow the trap to dry out during heating season. Keeping trap primed at all times will enable the water to flow properly. See Figure 55, p. 59 for 59 Installation appropriate dimensions required in a negative pressure system. Supply/Return Pipe Connections A steel braided hose without a shut-off device is the least expensive means of connecting the heat pump to the supply/return water loop. Deluxe ball valve hose kit Figure 56. Supply/return pipe connections Actuator Ball Valve w/PT Valve Body RETURN TO LOOP WATER-OUT Ball Valve w/PT SUPPLY FROM CENTRAL PUMP WATER-IN AUTOMATIC BALANCING HOSE KIT Optional Strainer/ Blowdown Valve w/Hose Connector Connect the supply and return hoses to the water-inlet (from supply) and water-outlet (to return) of the unit. For vibration isolation, it is recommended that flexible steel braided hoses be installed instead of hard piping the equipment to the main loop system. Figure 56, p. 60 shows connection of a Hays Measurflo® balancing hose kit to the water-in and water-out of a vertical unit. With the addition of a shut-off device on the supply and return of the system, the unit may be isolated during service or maintenance situation.This system may be installed as a wide open (full water flow to the equipment) design, or manually balanced by utilizing the pressure/ temperature ports on the top of the ball valve/shut-off device. Note: Figure 56, p. 60 example incorporates the Hays Measurflo® balancing hose kit and a 2-position isolation valve into the system design. An isolation valve is often used in variable speed pumping applications.The isolation valve is designed to stop water flow to the unit during non operation times.This allows the loop water pumps to run only when a requirement for pumping is needed for greater energy efficiency of the overall system design. Manual balance hose kit Types of Hose Connections Whether installing the units in a central pump (main/ auxiliary pump for the entire zone) design, or as a distributed pump (1-pump per unit) design, a shut-off device and flexible hose is recommended to transition from the hard piping of the closed or open loop water system to the unit.There are multiple hose combinations which may be used to fit the design or specification criteria for the installation. Flexible hoses Mesurmeter w/PT’s Actuator Valve Body Ball Valve w/PT Ball Valve w/PT Optional Strainer/ Blowdown Valve w/Hose Connector A circuit setter provides a means of manually balancing the water flow to the heat pump.This manual in-line balancing method is accurate up to ±20%. In order to determine flow rate, the user must record both handle position, and differential pressure drop.Then, the user must consult a chart containing both pieces of information and make the necessary adjustments to the circuit setter. Return Supply 60 WSHP-SVX01N-EN Installation 6. Shut down pumps and supplementary heat system. Reconnect the hoses placing the water-to-refrigerant heat exchanger in the water circulating system. Automatic balance hose kit Actuator Inline Mesurflo Balance Valve Ball Valve Valve Body Note: Vents should be open when the pumps and supplementary heat system are shut down. Field Installed Power Wiring Ball Valve w/PT Optional Strainer/ Blowdown Valve w/Hose Connector For self balancing flow control, a Hays Measurflo® balancing hose kit provides a constant flow rate over the pressure differential range of 2 – 80 psid. As system pressures change (through the addition of heat pumps, for example) each individual flow control valve will automatically adjust to the new system conditions. Additional accessories, such as a strainer are recommended for use to eliminate contaminants from entering the co-axial water-to-refrigerant heat exchanger. Cleaning and Flushing the Water Loop After the piping system is complete, the flexible hose connectors should be doubled back to complete the water circuit external to the unit (avoiding trash settle-out in the condenser). An extra pipe may be necessary to connect the hose kits. 1. Water circulation system should be filled with clean water using the water make up connections. Note: Air vents should be open during filling. 2. With the air vents closed, start the circulating pump and then crack the air vents to bleed off the trapped air, assuring circulation through all components of the system. Note: Make up water must be available to the system to replace the volume formerly occupied by the air that is bled off. 3. With the air vented and the water circulating, the entire system should be checked for leaks with repairs made as required. 4. Operate the supplementary heat system (boiler) making checks per manufacturer’s instructions. During this operation, visual checks should be made for leaks that may have occurred due to increased heat. Repair as required. 5. Open the system at the lowest point for the initial blow down (making sure the make up water is equal to the water being dumped). Continue blow down until the water leaving the drain runs clear, but not less than 2 hours. WSHP-SVX01N-EN WARNING Proper Field Wiring and Grounding Required! All field wiring MUST be performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field wiring installation and grounding as described in NEC and your local/state electrical codes. Failure to follow codes could result in death or serious injury. NOTICE: Use Copper Conductors Only! Unit terminals are not designed to accept other types of conductors. Failure to use copper conductors could result in equipment damage. Verify that the power supply available is compatible with the unit’s nameplate. Use only copper conductors to connect the power supply to the unit. Main Unit Power Wiring WARNING Proper Field Wiring and Grounding Required! All field wiring MUST be performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field wiring installation and grounding as described in NEC and your local/state electrical codes. Failure to follow codes could result in death or serious injury. A field supplied disconnect switch must be installed at or near the unit in accordance with the National Electric Code (NEC latest edition). Location of the applicable electric service entrance for HIGH (line voltage) may be found in the Dimensions section of this manual. The high-voltage connection is made at the 1K1 contactor or 1TB1 power block inside the unit control box. See Figure 57, p. 62. Refer to the customer connection diagram that is shipped with the unit for specific termination points. Provide proper grounding for the unit in accordance with the local and national codes. 61 Installation Figure 57. In air-flows from adjacent zones or other units. Power wiring example Controls Using 24 VAC Before installing any wire, refer to the electrical access locations in the “Unit Dimensions and Weights,” p. 14 of this manual. Ensure that the AC control wiring between the controls and the unit termination point does not exceed 3 Ohms/ conductor for the length of the run. NOTICE: Component Failure! Control Power Transformer The 24 V control power transformers are to be used only with the accessories called out in this manual. A 50 VA transformer is externally fused.Transformers rated greater than 50 VA are equipped with circuit breakers. If a circuit breaker trips, turn OFF all power to the unit before attempting to reset it. WARNING Hazardous Voltage! Resistance in excess of 3 Ohms per conductor could result in component failure due to insufficient AC voltage supply. Check all loads and conductors for grounds, shorts, and mis-wiring. Use copper conductors unless otherwise specified. Do not run the AC low-voltage wiring in the same conduit with the high voltage power wiring. Table 40. Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/ tagout procedures to ensure the power cannot be inadvertently energized. Failure to disconnect power before servicing could result in death or serious injury. The transformer is located in the control panel. Thermostat Location 24V AC conductors Distance from unit to control Recommended wire size 000-460 ft 18 gauge 461-732 ft 16 gauge 733-1000 ft 14 gauge Figure 59. Low-voltage connection (GEH/V ½-5 ton and EXH/V(a) ½-6 ton equipment) Basic Controls Wall Mounted Thermostat Figure 58. Thermostat/sensor location NO NO 5 Feet YES NO O 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Deluxe Controls Wall Mounted Thermostat 1TB1 1TB1 24 VAC FAN REVERSING VALVE (COOL) COMPRESSOR & VAR SPD PUMP SOLENOID 24 VAC GENERAL ALARM OUTPUT 24 VAC COMMON & VAR SPD PUMP SOLENOID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 VAC FAN REVERSING VALVE (COOL) COMPRESSOR & VAR SPD PUMP SOLENOID 24 VAC COMMON & VAR SPD PUMP SOLENOID ELECTRIC HEAT 24 VAC COMPRESSOR DISABLE INPUT 24 VAC COMPRESSOR DISABLE INPUT ALARM CONTACT OUTPUT ALARM CONTACT OUTPUT Deluxe Controls with Reheat 1TB1 Location of the thermostat or zone sensor is an important element of effective room control. Areas where the thermostat or zone sensor should not be located include: • Behind doors or corners • Near hot or cold air ducts • Near radiant heat (heat emitted from appliances or the sun) • Near concealed pipes or chimneys • On outside walls or other non conditioned surfaces 62 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 VAC FAN REVERSING VALVE (COOL) COMPRESSOR 24 VAC COMMON & VAR SPD PUMP SOLENOID 24 VAC COMPRESSOR DISABLE INPUT 24 VAC COMPRESSOR DISABLE INPUT HUMIDISTAT VAR SPD PUMP SOLENOID ALARM CONTACT OUTPUT ALARM CONTACT OUTPUT (a) Basic controls not available on EXH/V units Low-voltage connection diagrams for basic and deluxe 24 V control packages mounted on ½-6 ton equipment sizes are shown in Figure 59, p. 62. WSHP-SVX01N-EN Installation Figure 60. Low-voltage connection (GEH/V 6-25 ton) Deluxe Controls with -all Heat Pump Units w/ Reheat using X13511090010 (T8511) 1TB2 1TB2 24 VAC (R) FAN (G) COMPRESSOR 1 (Y1) COMPRESSOR 2 (Y2) REVERSING VALVE (0) & HUMIDISTAT 24 VAC COMMON (C) & WATER ISOLATION VA COMPRESSOR DISABLE COMPRESSOR DISABLE ALARM ALARM ELECTRIC HEAT ELECTRIC HEAT HUMIDISTAT WATER ISOLATION VALVE 3RD STAGE HEAT (W3) NOT USED 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Deluxe Controls with -all Heat Pump Units w/ Reheat using X13511091010/X13511092010 (T7300) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 24 VAC (R) FAN (G) COMPRESSOR 1 (Y1) COMPRESSOR 2 (Y2) REVERSING VALVE (0) & HUMIDISTAT 24 VAC COMMON (X) & WATER ISOLATION VA COMPRESSOR DISABLE COMPRESSOR DISABLE ALARM ALARM ELECTRIC HEAT ELECTRIC HEAT HUMIDISTAT WATER ISOLATION VALVE 3RD STAGE HEAT (W1) NOT USED WARNING Proper Field Wiring and Grounding Required! All field wiring MUST be performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field wiring installation and grounding as described in NEC and your local/state electrical codes. Failure to follow codes could result in death or serious injury. 1. Remove service access panel at the unit front. Figure 61. Service access panel Deluxe Controls with -all Heat Pump Units without Reheat using X13511090010 (T8511) 1TB2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Deluxe Controls with -all Heat Pump Units without Reheat using X13511091010/X13511092010 (T7300) 1TB2 24 VAC (R) FAN (G) COMPRESSOR 1 (Y1) & WATER ISOLATION VA COMPRESSOR 2 (Y2) REVERSING VALVE (0) & HUMIDISTAT 24 VAC COMMON (C) & WATER ISOLATION VA COMPRESSOR DISABLE COMPRESSOR DISABLE ALARM ALARM ELECTRIC HEAT ELECTRIC HEAT HUMIDISTAT NOT USED 3RD STAGE HEAT (W3) NOT USED 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 24 VAC (R) FAN (G) COMPRESSOR 1 (Y1) & WATER ISOLATION VA COMPRESSOR 2 (Y2) REVERSING VALVE (0) & HUMIDISTAT 24 VAC COMMON (X) & WATER ISOLATION VA COMPRESSOR DISABLE COMPRESSOR DISABLE ALARM ALARM ELECTRIC HEAT ELECTRIC HEAT HUMIDISTAT NOT USED 3RD STAGE HEAT (W1) NOT USED Low-voltage connection diagrams for deluxe 24V control packages for these thermostats mounted on 6-25 ton equipment sizes are shown in Figure 60, p. 63. 2. Find the blower motor relay.The relay is located in Figure 62, p. 63.The relay location is consistent in all control configurations. Figure 62. Relay location For controls using DC analog input/outputs, see appropriate installation, operation and diagnostic manuals for connection, WSHP-PRB002-EN (ZN524). Blower Motor Speed-Tap Retrofit Note: For GEH/V ½-5 ton units only. Motors installed in the unit include 4-speed or 3-speed configurations. All voltages include a 4-speed configuration, with the exception of 380V, 415V, 460V which contain a 3-speed arrangement and 575V which contains a 2-speed arrangement.To modify the rpm of the motor, the following steps must be followed. WARNING Hazardous Voltage! Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/ tagout procedures to ensure the power can not be inadvertently energized. Failure to disconnect power before servicing could result in death or serious injury. WSHP-SVX01N-EN Removing Speed-tap Wire 3. For units w/o Hot Gas Reheat: Remove undesired speed-tap wire from 1K4 relay at spade 3. Wire tie the lead, to eliminate a short. 4. For units with Hot Gas Reheat: Remove undesired speed-tap wire from 1K8 relay at spade 6. Wire tie the lead, to eliminate a short. Hot Gas Reheat requires both speed taps to be adjusted to enable reheat as the lower speed tap. 63 Installation Hole Plug Installation Figure 63. Wiring change Figure 65. Hole plug installation Connecting Desired Speed-tap Wire 5. For units without Hot Gas Reheat: Select desired speed-tap wire. Connect desired speed tap wire to 1K4 relay at spade 3. 6. For units with Hot Gas Reheat Select desired speed-tap wire. Connect desired speed tap wire to 1K8 relay at spade 6. Figure 64. Connecting speed-tap wire 1. Locate two Hayco plastic plugs enclosed with the Installation, Operation, and Maintenance manual. 2. Use these plugs to plug the two shipping bolt holes in the bottom of the GEVE/EVXVE units after shipping bolt removal. Air Flow Adjustment Note: GEH/V 6-25 ton units only. To increase cfm, loosen the turns open set screw on the sheave, and turn the sheave clockwise.To decrease cfm, Loosen the turns open set screw on the sheave, and turn the sheave counterclockwise. To increase belt tension, loosen the adjustment bolt and pull motor mounting plate back until the belt is tight. Tighten the adjustment bolt after the belt has reached the desired tension. See Figure 66, p. 65 for fan motor and sheave adjustment 7. Install service front panel. Reconnect power to the unit. Table 41. 4-speed motor (115, 208, 230, 265) Lead Colors Lead Black Blue Orange Red Speed High Medium High Medium Low Low Table 42. WARNING Rotating Components! Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/ tagout procedures to ensure the power can not be inadvertently energized. Failure to disconnect power before servicing could result in death or serious injury. 3-speed motor (380, 415, 460) Lead Colors Lead Black Blue Orange Speed High Medium Low Note: When using the medium or low speed tap, the purple wire must be jumpered to the high speed tap (blk). Table 43. 2-speed motor (575) Lead Colors 64 Lead Black Blue Speed High Low WSHP-SVX01N-EN Installation Figure 66. Fan motor and sheave adjustment 1.Belt setting. Connect the power to the unit. If the power is not disconnected when the DIP switch is set, the motor will not be programmed to the new setting. 2.Adjustment Bolt and Plate Profile A = 110% of rated air flow 3.Sheave Profile C = 90% of rated air flow Profile B = 100% of rated air flow Profile D = 80% of rated air flow 1 Waterside Economizer Installation 2 Note: GEH ½-5 and EXH ½-6 ton units. WARNING Hazardous Voltage! 3 Figure 67. ECM control board and dip switch setting Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/ tagout procedures to ensure the power can not be inadvertently energized. Failure to disconnect power before servicing could result in death or serious injury. WARNING Proper Field Wiring and Grounding Required! Dip switch to select profile All field wiring MUST be performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field wiring installation and grounding as described in NEC and your local/state electrical codes. Failure to follow codes could result in death or serious injury. The following steps were sequenced to aid in the installation and mating of a water side economizer to a water-source heat pump (GEH ½-5 ton) and (EXH 1½-6 ton). 1. Remove the control side service panel of the watersource heat pump unit. 2. Remove rubber isolation grommets from the return-air section. Place them in a convenient location. 3. Attach ducted panel to the water-source heat pump unit with six factory provided screws.This panel is shipped loose with the water-source heat pump but must be field installed to the unit. Note: EXH/V ½ -6 ton high efficiency units only: Units are shipped from the factory on profile setting B. To adjust the cfm, disconnect the power to the unit. Set the DIP switch located in the control box to the desired profile WSHP-SVX01N-EN 65 Installation Figure 68. Step 3 6. Install the SUPPLY and RETURN hoses to the: a. 2-position valve’s threaded connection b. water-out threaded connection of the water-source heat pump Figure 71. Step 6 4. Attach the water side economizing unit to the ducted panel of the water-source heat pump with 10-factory provided screws.The economizing package fits to the outside of the of the water-source heat pump.Trane recommends the mating of the systems be made via 3screws spaced evenly across the top, 3-screws spaced evenly across the bottom (installed immediately after hanging the unit), and 2-screws on each side. Note: Waterside economizer option is configured for right return. Left return requires additional field piping. Figure 69. Step 4 7. Verify the control board for the water side economizer is located at the back of the control box.The temperature rating of this board is factory set to 55ºF. For units with boilerless (electric heat) control and water side economizer, the boilerless control board is factory set to 45ºF. Figure 72. Step 7 5. Install the 18-inch steel braided hose between the upper most piping connection of the economizer, and the water-in of the heat pump.The hose is shipped loose with the water-side economizer. Figure 70. Step 5 8. Thread the bulb and wire through the low voltage hole of the water-source heat pump. See Figure 73, p. 67. 66 WSHP-SVX01N-EN Installation Figure 73. Step 8 9. Wire-tie the sensor to the water SUPPLY side of the piping (ON, or BEFORE) the 2-position valve. See Figure 74, p. 67. Figure 74. Step 9 Figure 76. Step 11 12. Wire the valve to the terminal strip according to the unit wire diagram located on the service control panel. RED = 1TB1-14 BLK = 1TB1-18 WHT = 1TB1-15 See Figure 77, p. 67. Figure 77. Step 12 10. Bundle excess sensor wire, and wire tie the bundle neatly. See Figure 75, p. 67. Figure 75. Step 10 13. Bundle excess valve wire, and wire tie the bundle neatly. See Figure 78, p. 67. Figure 78. Step 13 11. Thread the valve’s wire lead through the low voltage hole of the heat pump. See Figure 76, p. 67. 14. Install control side service panel. WSHP-SVX01N-EN 67 Installation 15. Install the hanging isolation grommets (see Figure 79, p. 68) into the hanging bracketsThe unit isolators were located in the return-air section of the unit. See Step 2. Isolators for the economizing package are located with the economizer. Table 44. Economizer part numbers GEH Unit 60 Hz GEH Unit 50 Hz Waterside Economizer Part Number 006-015 006-012 4474 1690 0100 018-030 015-024 4474 7072 0100 036-042 030-036 4474 1692 0100 048-060 042-048 4474 1693 0100 EXH Unit 60 hz EXH Unit 50 Hz Waterside Economizer Part Number 006-015 — 4474 1690 0100 018-024 — 4474 7072 0100 030-036 — 4474 1692 0100 042-070 — 4474 1639 0100 Note: GEH ½-5 ton and EXH ½-6 ton. Figure 79. Step 15 Waterside Economizer Installation for GEH and GEV 6 to 25 Ton Models 16. Insulate the economizing piping package and the supply/return/by-pass hoses (3-hoses) via field provided pipe insulation. Insulating the piping will stop condensation from forming on the pipe and dripping onto the ceiling tiles. Note: Trane does not provide insulation on the economizing piping package.This insulation must be field provided and field installed. Note: Trane does not provide condensate overflow protection of the waterside economizer.This must be field provided and installed. 17. Install filter rack (top and bottom) to the economizing package.The filter rack is located in the unit’s packaging along with the filter. 18. Hang unit. See Figure 54, p. 59 for hanging of the packaged unit. Bottom screws referenced in Step 4 must be installed at this time. WARNING Hazardous Voltage! Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/ tagout procedures to ensure the power can not be inadvertently energized. Failure to disconnect power before servicing could result in death or serious injury. WARNING Proper Field Wiring and Grounding Required! All field wiring MUST be performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field wiring installation and grounding as described in NEC and your local/state electrical codes. Failure to follow codes could result in death or serious injury. 19. Field pipe the drain lines of the waterside economizer and water-source heat pump together prior to installing a condensate trap (see Figure 80, p. 68. See Figure 55, p. 59 for proper trapping of condensation. 1. Remove the filter frame from the unit. Figure 80. Step 19 3. Remove the control box service panel from the unit. 2. Remove the waterside service panel from the unit. 4. Remove the economizer and miscellaneous mounting parts from it’s packaging. 5. GEV ONLY: Mount the economizer support angle (4475 1637 0100) found in the economizer packaging in the same holes of the return air filter frame removed in Step 1.The support angle screws into the unit roof. 6. GEV ONLY: Hang the economizer assembly from the economizer support angle mounted in Step 5. 7. 68 Secure the economizer to the unit using the four plates (4475 1630 0100) found in the economizer packaging. Two plates should be applied to each economizer side. GEV ONLY: Secure the bracket on the bottom of the WSHP-SVX01N-EN Installation economizer cabinet to the unit compressor compartment center post. 8. Install the field portion of the water piping and the 3way valve together. Note: Entering water is on the AB port. 9. Verify the control board for the waterside economizer is located at the back of the control box.The temperature rating of this board is factory set to 55ºF. being sucked through the drain line causing condensate to spit or build-up in the economizer or unit drain pans. Field pipe the drain lines of the waterside economizer and water-source heat pump together prior to installing a condensate trap. See page “Condensate Drain Connection,” p. 59 for proper trapping of condensation. 10. Thread the economizer’s entering water temperature sensor (4RT1) through the water-in line of the watersource heat pump upstream from the valve.This sensor is used by the economizer’s 3-way valve to determine if water flow should be directed through the waterside economizing coil. 11. Tie wrap the thermistor to the water line (supply side) upstream of the water pipe to the economizer.The thermistor must be situated so that the thermistor is capable of reading the actual entering water temperature regardless of the economizer’s on or off situation. 12. Insulate the thermistor with tubing insulation. 13. Tie wrap each end of the tubing insulation to prevent air filtration.The tie wraps and insulation are located in a bag and shipped inside of the unit. 14. Thread the factory wire harness through the low voltage hole of the heat pump to the 3-way valve’s wire harness. 15. Connect the factory installed wire harness to the to the wire harness supplied with the 3-way valve (see Table 45, p. 69). Table 45. Actuator/factory harness wire table Actuator Wire # Color Factory Harness Wire # Color 1 BLK = 25L-Black 2 WHT = 23T-White 3 WHT = 73A-White 16. Bundle excess valve wire, and wire tie the bundle neatly. 17. Install control side service panel to the heat pump. 18. Install the unit filter frame to the economizing inlet. 19. Insulate the economizing piping package with field supplied pipe insulation. Insulating the piping will help stop condensation from forming on the pipe. Note: Trane does not provide insulation on the economizing piping package.This insulation must be field provided and field installed. Note: Trane does not provide condensate overflow protection of the waterside economizer.This must be field provided and field installed. 20. Install waterside service panel to the heat pump. 21. The economizer condensate line must be trapped prior to the unit’s drain line.This helps prevent air from WSHP-SVX01N-EN 69 Waterside Economizer Start-Up Sequence 1. Set the thermostat to the highest position. 2. Set the thermostat system switch to COOL with the fan control to AUTO.The compressor should NOT run. 3. Reduce the thermostat setting until the compressor, reversing valve, solenoid valve, and loop pump are energized. Adjust water flow utilizing pressure/ temperature plugs and comparing to tables contained in specification sheet data. Water leaving the heat exchanger should be warmer than the entering water temperature (approximately 9-12ºF); blower operation should be smooth; compressor and blower amps should be within data plate ratings; the suction line should be cool with no frost observed in the refrigerant circuit. 4. Check the cooling refrigerant pressures against values in Table 54, p. 94. Note: If cooling mode is activated, and the entering water temperature of the heat pump falls below 55ºF, the 2-position, water side economizing valve will become energized (open) and compressor operation will halt allowing for free cooling in the space. 5. Turn the thermostat system switch to the OFF position. Unit should stop running and the reversing valve should de-energize. 70 6. Leave unit off for approximately FIVE minutes to allow for pressure equalization. 7. Turn the thermostat to the lowest setting. 8. Set the thermostat system switch to the HEAT position. 9. Adjust the temperature setting upward until the unit is energized. Warm air should blow from the register. A water temperature decrease of approximately 5-9°F leaving the heat exchanger should be noted.The blower and compressor operation should be smooth with no frost observed in the refrigeration circuit. 10. Check the heating refrigerant pressures against values in Table 54, p. 94. Note: For units with boilerless electric heat option: In heating mode, if the entering water temperature of the heat pump falls below 45ºF, the electric heater will be energized, and compressor operation will halt. Once the entering water temperature rises above 50ºF, the boilerless controls returns the unit to normal operation. 11. Set the thermostat to maintain the desired space temperature. 12. Instruct the owner on system operation. WSHP-SVX01N-EN Waterside Economizer Start-Up Sequence Table 46. Waterside economizing three-way valve specifications Unit Size (60 Hz) Unit Size (50 Hz) Valve Conn. Size Valve Pres. Rating "Valve Closeoff pressure Valve Temp. Range Actuator GEH006-015 GEH006-012 1/2 FPT 600 psi 200 psi "0ºF to 212ºF -18ºC to 121ºC Non-spring return type 24 VAC +/- 20% 135 second stroke time 10 Cv at full port GEH018-042 GEH015-036 3/4 FPT 600 psi 200 psi "0ºF to 212ºF -18ºC to 121ºC Non-spring return type 24 VAC +/- 20% 135 second stroke time 30 Cv at full port Non-spring return type 24 VAC +/- 20% 135 second stroke time 23 Cv at full port GEH048-060 GEH042-060 1 FPT 600 psi 200 psi "0ºF to 212ºF -18ºC to 121ºC GEV/GEH 6-7½ Ton GEV 6 Ton 1¼ FPT 600 psi 200 psi 0ºF to 212ºF -18ºC to 121ºC Non-spring return type 24 VAC +/- 20% 135 second stroke time 33 Cv at full port GEV/GEH 10-15 Ton GEV/GEH 7½-12½ Ton 1½ FPT 600 psi 200 psi 0ºF to 212ºF -18ºC to 121ºC Non-spring return type 24 VAC +/- 20% 135 second stroke time 37 Cv at full port GEV 20 & 25 Ton GEV 15 & 20 Ton 2 FPT 600 psi 200 psi 0ºF to 212ºF -18ºC to 121ºC Non-spring return type 24 VAC +/- 20% 135 second stroke time 57 Cv at full port EXH006-015 — 1/2 FPT 600 psi 200 psi 0ºF to 212ºF -18ºC to 121ºC Non-spring return type 24 VAC +/- 20% 135 second stroke time 10 Cv at full port 200 psi 0°F to 212°F -18°C to 121°C Non-spring return type 24 VAC +/- 20% 135 second stroke time 30 Cv at full port 200 psi 0°F to 212°F -18°C to 121°C Non-spring return type 24 VAC +/- 20% 135 second stroke time 23 Cv at full port EXH 018-036 EXH 042-070 — — 3/4 FPT 1 FPT 600 psi 600 psi Note: The valve body is constructed from forged brass with nickel plating, with the ball and stem constructed of stainless steel. For other information pertaining to the economizing water valve, see the valve’s data plate. WSHP-SVX01N-EN 71 Electrical Data Table 47. Electrical data: standard static motors, ½ to 5 tons GEH*/GEV* Maximum Total Comp Comp Blower Blower Fan Minimum Overcurrent Electric Electric Unit RLA LRA No. of Cmp Motor Motor Motor Circuit Protective Heat Heat FLA (ea) (ea) Comp. MCC FLA hp Num. Ampacity Device kW Amps Model No. Volts GEH/GEV006 115/60/1 6.8 5.6 30.0 1 7.5 1.20 1/12 1 8.20 15 0.0 0.0 GEH/GEV006 208/60/1 3.9 3.3 14.0 1 4.2 0.60 1/12 1 4.73 15 0.0 0.0 GEH/GEV006 208/60/1 4.5 3.3 14.0 1 4.2 0.60 1/12 1 5.68 15 0.8 3.9 GEH/GEV006 230/60/1 3.8 3.2 15.0 1 4.2 0.60 1/12 1 4.60 15 0.0 0.0 GEH/GEV006 230/60/1 4.9 3.2 15.0 1 4.2 0.60 1/12 1 6.18 15 1.0 4.3 GEH/GEV006 220-240/50/1 3.4 2.9 17.0 1 4.0 0.52 1/12 1 4.15 15 0.0 0.0 GEH/GEV006 220-240/50/1 7.4 2.9 17.0 1 4.0 0.52 1/12 1 9.19 15 1.6 6.8 GEH/GEV006 265/60/1 3.0 2.5 11.0 1 3.5 0.52 1/12 1 3.65 15 0.0 0.0 GEH/GEV006 265/60/1 5.5 2.5 11.0 1 3.5 0.52 1/12 1 6.92 15 1.3 5.0 GEH/GEV009 115/60/1 7.6 6.4 36.0 1 8.6 1.20 1/12 1 9.20 15 0.0 0.0 GEH/GEV009 208/60/1 4.3 3.7 16.0 1 4.8 0.60 1/12 1 5.23 15 0.0 0.0 GEH/GEV009 208/60/1 6.5 3.7 16.0 1 4.8 0.60 1/12 1 8.14 15 1.2 5.9 GEH/GEV009 230/60/1 4.1 3.5 17.0 1 4.8 0.60 1/12 1 4.98 15 0.0 0.0 GEH/GEV009 230/60/1 7.1 3.5 17.0 1 4.8 0.60 1/12 1 8.90 15 1.5 6.5 GEH/GEV009 220-240/50/1 6.0 5.3 23.0 1 7.4 0.72 1/8 1 7.35 15 0.0 0.0 GEH/GEV009 220-240/50/1 9.8 5.3 23.0 1 7.4 0.72 1/8 1 12.20 15 2.2 9.0 GEH/GEV009 265/60/1 3.3 2.8 13.0 1 3.7 0.52 1/12 1 4.02 15 0.0 0.0 GEH/GEV009 265/60/1 8.1 2.8 13.0 1 3.7 0.52 1/12 1 10.08 15 2.0 7.5 GEH/GEV012 115/60/1 13.7 12.1 58.0 1 16.9 1.57 1/8 1 16.70 25 0.0 0.0 GEH/GEV012 208/60/1 7.0 6.3 30.0 1 8.8 0.70 1/8 1 8.58 15 0.0 0.0 GEH/GEV012 208/60/1 8.5 6.3 27.0 1 8.8 0.70 1/8 1 10.67 15 1.6 7.8 GEH/GEV012 230/60/1 7.0 6.3 30.0 1 8.8 0.70 1/8 1 8.58 15 0.0 0.0 GEH/GEV012 230/60/1 9.4 6.3 30.0 1 8.8 0.70 1/8 1 11.74 15 2.0 8.7 7.4 6.7 30.0 1 9.4 0.72 1/8 1 9.10 15 0.0 0.0 GEH/GEV012 220-240/50/1 12.0 6.7 30.0 1 9.4 0.72 1/8 1 14.96 15 2.7 11.3 GEH/GEV012 265/60/1 5.7 5.0 23.0 1 7.0 0.72 1/8 1 6.97 15 0.0 0.0 GEH/GEV012 265/60/1 10.7 5.0 23.0 1 7.0 0.72 1/8 1 13.40 15 2.7 10.0 GEH/GEV015 208/60/1 8.6 7.9 36.0 1 11.1 0.70 1/8 1 10.58 15 0.0 0.0 GEH/GEV015 208/60/1 10.3 7.9 36.0 1 11.1 0.70 1/8 1 12.89 15 2.0 9.6 GEH/GEV015 230/60/1 8.6 7.9 36.0 1 11.1 0.70 1/8 1 10.58 15 0.0 0.0 GEH/GEV015 230/60/1 11.6 7.9 36.0 1 11.1 0.70 1/8 1 14.46 15 2.5 10.9 9.0 8.2 36.0 1 11.5 0.80 1/8 1 11.05 15 0.0 0.0 GEH/GEV015 220-240/50/1 14.5 8.2 36.0 1 11.5 0.80 1/8 1 18.08 20 3.3 13.7 GEH/GEV015 265/60/1 7.1 6.4 30.0 1 9.0 0.72 1/8 1 8.72 15 0.0 0.0 GEH/GEV015 265/60/1 13.2 6.4 30.0 1 9.0 0.72 1/8 1 16.47 20 3.3 12.5 GEH/GEV018 208/60/1 10.5 9.6 42.0 1 13.4 0.90 1/8 1 12.90 20 0.0 0.0 GEH/GEV018 208/60/1 12.7 9.6 42.0 1 13.4 0.90 1/8 1 15.91 20 2.5 11.8 GEH/GEV018 230/60/1 10.5 9.6 42.0 1 13.4 0.90 1/8 1 12.90 20 0.0 0.0 GEH/GEV018 230/60/1 13.9 9.6 42.0 1 13.4 0.90 1/8 1 17.43 20 3.0 13.0 GEH/GEV018 220-240/50/1 11.1 9.6 54.0 1 15.0 1.53 1/3 1 13.53 20 0.0 0.0 GEH/GEV018 220-240/50/1 19.7 9.6 54.0 1 15.0 1.53 1/3 1 24.57 25 4.4 18.1 GEH/GEV018 7.7 35.0 1 10.8 0.80 1/8 1 10.43 15 0.0 0.0 GEH/GEV012 220-240/50/1 GEH/GEV015 220-240/50/1 265/60/1 8.5 continued on next page 72 WSHP-SVX01N-EN Electrical Data Table 47. Electrical data: standard static motors, ½ to 5 tons (continued)GEH*/GEV* Model No. Volts GEH/GEV018 265/60/1 Maximum Total Comp Comp Blower Blower Fan Minimum Overcurrent Electric Electric Unit RLA LRA No. of Cmp Motor Motor Motor Circuit Protective Heat Heat FLA (ea) (ea) Comp. MCC FLA hp Num. Ampacity Device kW Amps 15.9 7.7 35.0 1 10.8 0.80 1/8 1 19.87 20 4.0 15.1 GEH/GEV018 380-415/50/3 5.2 4.2 28.0 1 6.5 0.95 1/3 1 6.20 15 0.0 0.0 GEH/GEV018 380-415/50/3 7.0 3.6 28.0 1 5.6 0.95 1/3 1 8.75 15 4.4 6.1 GEH/GEV024 208/60/1 14.9 12.8 58.3 1 20.0 2.10 1/3 1 18.10 30 0.0 0.0 GEH/GEV024 208/60/1 17.8 12.8 58.3 1 20.0 2.10 1/3 1 22.22 30 3.3 15.7 GEH/GEV024 230/60/1 14.9 12.8 58.3 1 20.0 2.10 1/3 1 18.10 30 0.0 0.0 GEH/GEV024 230/60/1 19.5 12.8 58.3 1 20.0 2.10 1/3 1 24.36 30 4.0 17.4 GEH/GEV024 220-240/50/1 12.7 11.2 60.0 1 17.5 1.53 1/3 1 15.53 25 0.0 0.0 GEH/GEV024 220-240/50/1 24.0 11.2 60.0 1 17.5 1.53 1/3 1 30.04 35 5.4 22.5 GEH/GEV024 265/60/1 11.1 9.6 54.0 1 15.0 1.53 1/3 1 13.53 20 0.0 0.0 GEH/GEV024 265/60/1 21.5 9.6 54.0 1 15.0 1.53 1/3 1 26.91 30 5.3 20.0 GEH/GEV024 208/60/3 9.2 7.7 53.7 1 12.0 1.53 1/3 1 11.16 15 0.0 0.0 GEH/GEV024 208/60/3 10.6 7.7 53.7 1 12.0 1.53 1/3 1 13.22 15 3.3 9.0 GEH/GEV024 230/60/3 9.8 7.7 53.7 1 12.0 2.10 1/3 1 11.73 15 0.0 0.0 GEH/GEV024 230/60/3 12.1 7.7 53.7 1 12.0 2.10 1/3 1 15.18 20 4.0 10.0 GEH/GEV024 380-415/50/3 5.2 4.2 28.0 1 6.5 0.95 1/3 1 6.20 15 0.0 0.0 GEH/GEV024 380-415/50/3 8.5 4.2 28.0 1 6.5 0.95 1/3 1 10.58 15 5.4 7.5 GEH/GEV024 460/60/3 4.6 3.6 28.0 1 5.6 0.95 1/3 1 5.45 15 0.0 0.0 GEH/GEV024 460/60/3 7.6 3.6 28.0 1 5.6 0.95 1/3 1 9.50 15 5.3 6.7 GEH/GEV030 208/60/1 16.2 14.1 73.0 1 22.0 2.10 1/3 1 19.73 30 0.0 0.0 GEH/GEV030 208/60/1 21.8 14.1 73.0 1 22.0 2.10 1/3 1 27.26 30 4.1 19.7 GEH/GEV030 230/60/1 16.2 14.1 73.0 1 22.0 2.10 1/3 1 19.73 30 0.0 0.0 GEH/GEV030 230/60/1 23.8 14.1 73.0 1 22.0 2.10 1/3 1 29.80 30 5.0 21.7 GEH/GEV030 220-240/50/1 19.5 16.7 79.0 1 26.0 2.77 1/2 1 23.65 40 0.0 0.0 GEH/GEV030 220-240/50/1 29.9 13.5 72.0 1 21.0 2.77 1/2 1 37.42 40 6.5 27.2 GEH/GEV030 265/60/1 12.7 11.2 60.0 1 17.5 1.53 1/3 1 15.53 25 0.0 0.0 GEH/GEV030 265/60/1 26.4 11.2 60.0 1 17.5 1.53 1/3 1 33.04 35 6.6 24.9 GEH/GEV030 208/60/3 11.0 8.9 58.0 1 13.9 2.10 1/3 1 13.23 20 0.0 0.0 GEH/GEV030 208/60/3 13.5 8.9 58.0 1 13.9 2.10 1/3 1 16.85 20 4.1 11.4 GEH/GEV030 230/60/3 11.0 8.9 58.0 1 13.9 2.10 1/3 1 13.23 20 0.0 0.0 GEH/GEV030 230/60/3 14.7 8.9 58.0 1 13.9 2.10 1/3 1 18.31 20 5.0 12.6 7.5 GEH/GEV030 380-415/50/3 5.8 38.0 1 9.0 1.70 1/2 1 8.95 15 0.0 0.0 GEH/GEV030 380-415/50/3 10.8 5.8 38.0 1 9.0 1.70 1/2 1 13.46 15 6.5 9.1 GEH/GEV030 460/60/3 5.2 4.2 28.0 1 6.5 0.95 1/3 1 6.20 15 0.0 0.0 GEH/GEV030 460/60/3 9.2 4.2 28.0 1 6.5 0.95 1/3 1 11.54 15 6.6 8.3 GEH/GEV036 208/60/1 20.3 16.7 79.0 1 26.0 3.60 1/2 1 24.48 40 0.0 0.0 GEH/GEV036 208/60/1 27.2 16.7 79.0 1 26.0 3.60 1/2 1 33.95 40 4.9 23.6 GEH/GEV036 230/60/1 20.3 16.7 79.0 1 26.0 3.60 1/2 1 24.48 40 0.0 0.0 GEH/GEV036 230/60/1 29.7 16.7 79.0 1 26.0 3.60 1/2 1 37.11 40 6.0 26.1 GEH/GEV036 265/60/1 16.3 13.5 72.0 1 21.0 2.77 1/2 1 19.65 30 0.0 0.0 GEH/GEV036 265/60/1 32.8 13.5 72.0 1 21.0 2.77 1/2 1 40.96 45 8.0 30.0 GEH/GEV036 208/60/3 14.0 10.4 73.0 1 16.3 3.60 1/2 1 16.60 25 0.0 0.0 GEH/GEV036 208/60/3 17.2 10.4 73.0 1 16.3 3.60 1/2 1 21.50 25 4.9 13.6 GEH/GEV036 230/60/3 14.0 10.4 73.0 1 16.3 3.60 1/2 1 16.60 25 0.0 0.0 continued on next page WSHP-SVX01N-EN 73 Electrical Data Table 47. Electrical data: standard static motors, ½ to 5 tons (continued)GEH*/GEV* Model No. Volts GEH/GEV036 230/60/3 GEH/GEV036 380-415/50/3 Maximum Total Comp Comp Blower Blower Fan Minimum Overcurrent Electric Electric Unit RLA LRA No. of Cmp Motor Motor Motor Circuit Protective Heat Heat FLA (ea) (ea) Comp. MCC FLA hp Num. Ampacity Device kW Amps 18.7 10.4 73.0 1 16.3 3.60 1/2 1 7.7 23.33 25 6.0 15.1 0.0 6.0 44.0 1 9.3 1.70 1/2 1 9.20 15 0.0 GEH/GEV036 380-415/50/3 11.6 6.0 44.0 1 9.3 1.70 1/2 1 14.56 15 7.2 9.9 GEH/GEV036 460/60/3 7.5 5.8 38.0 1 9.0 1.70 1/2 1 8.95 15 0.0 0.0 GEH/GEV036 460/60/3 11.7 5.8 38.0 1 9.0 1.70 1/2 1 14.60 15 8.0 10.0 GEH/GEV042 208/60/1 21.5 17.9 112.0 1 28.0 3.60 1/2 1 25.98 40 0.0 0.0 GEH/GEV042 208/60/1 31.0 17.9 112.0 1 28.0 3.60 1/2 1 38.75 40 5.7 27.4 GEH/GEV042 230/60/1 21.5 17.9 112.0 1 28.0 3.60 1/2 1 25.98 40 0.0 0.0 GEH/GEV042 230/60/1 34.0 17.9 112.0 1 28.0 3.60 1/2 1 42.54 45 7.0 30.4 GEH/GEV042 208/60/3 17.1 13.5 88.0 1 21.1 3.60 1/2 1 20.48 30 0.0 0.0 GEH/GEV042 208/60/3 19.4 13.5 88.0 1 21.1 3.60 1/2 1 24.28 30 5.7 15.8 GEH/GEV042 230/60/3 17.1 13.5 88.0 1 21.1 3.60 1/2 1 20.48 30 0.0 0.0 GEH/GEV042 230/60/3 21.2 13.5 88.0 1 21.1 3.60 1/2 1 26.46 30 7.0 17.6 7.7 6.3 55.0 1 9.9 1.40 1/2 1 9.28 15 0.0 0.0 6.3 55.0 1 9.9 1.40 1/2 1 16.71 20 8.6 12.0 GEH/GEV042 380-415/50/3 GEH/GEV042 380-415/50/3 13.4 GEH/GEV042 460/60/3 7.7 6.0 44.0 1 9.3 1.70 1/2 1 9.20 15 0.0 0.0 GEH/GEV042 460/60/3 13.4 6.0 44.0 1 9.3 1.70 1/2 1 16.72 20 9.3 11.7 GEH/GEV042 575/60/3 6.2 4.9 34.0 1 7.7 1.31 1/2 1 7.44 15 0.0 0.0 GEH/GEV048 208/60/1 24.2 21.4 135.0 1 33.4 2.80 1/2 1 29.55 50 0.0 0.0 GEH/GEV048 208/60/1 34.1 21.4 135.0 1 33.4 2.80 1/2 1 42.56 50 6.5 31.3 GEH/GEV048 230/60/1 24.2 21.4 135.0 1 33.4 2.80 1/2 1 29.55 50 0.0 0.0 GEH/GEV048 230/60/1 37.6 21.4 135.0 1 33.4 2.80 1/2 1 46.98 50 8.0 34.8 GEH/GEV048 208/60/3 17.3 14.5 98.0 1 22.6 2.80 1/2 1 20.93 35 0.0 0.0 GEH/GEV048 208/60/3 20.8 14.5 98.0 1 22.6 2.80 1/2 1 26.05 35 6.5 18.0 GEH/GEV048 230/60/3 17.3 14.5 98.0 1 22.6 2.80 1/2 1 20.93 35 0.0 0.0 GEH/GEV048 230/60/3 22.9 20.1 14.5 98.0 1 22.6 2.80 1/2 1 28.60 35 8.0 GEH/GEV048 380-415/50/3 10.5 7.8 52.0 1 12.1 2.70 1 1 12.45 20 0.0 0.0 GEH/GEV048 380-415/50/3 14.7 7.8 52.0 1 12.1 2.70 1 1 18.33 20 8.6 12.0 GEH/GEV048 460/60/3 7.7 6.3 55.0 1 9.9 1.40 1/2 1 9.28 15 0.0 0.0 GEH/GEV048 460/60/3 14.7 6.3 55.0 1 9.9 1.40 1/2 1 18.38 20 10.6 13.3 GEH/GEV048 575/60/3 7.4 6.0 41.0 1 9.4 1.40 1/2 1 8.90 15 0.0 0.0 GEH/GEV060 208/60/1 31.7 26.3 134.0 1 41.0 5.40 1 1 38.28 60 0.0 0.0 GEH/GEV060 208/60/1 36.7 26.3 134.0 1 41.0 5.40 1 1 45.81 60 6.5 31.3 GEH/GEV060 230/60/1 31.7 26.3 134.0 1 41.0 5.40 1 1 38.28 60 0.0 0.0 GEH/GEV060 230/60/1 40.2 26.3 134.0 1 41.0 5.40 1 1 50.23 60 8.0 34.8 GEH/GEV060 208/60/3 21.0 15.6 110.0 1 24.4 5.40 1 1 24.90 40 0.0 0.0 GEH/GEV060 208/60/3 23.4 15.6 110.0 1 24.4 5.40 1 1 29.30 40 6.5 18.0 GEH/GEV060 230/60/3 21.0 15.6 110.0 1 24.4 5.40 1 1 24.90 40 0.0 0.0 GEH/GEV060 230/60/3 25.5 15.6 110.0 1 24.4 5.40 1 1 31.85 40 8.0 20.1 GEH/GEV060 380-415/50/3 12.3 9.6 75.0 1 15.0 2.70 1 1 14.70 20 0.0 0.0 GEH/GEV060 380-415/50/3 14.7 9.6 75.0 1 15.0 2.70 1 1 18.33 20 8.6 12.0 GEH/GEV060 460/60/3 10.5 7.8 52.0 1 12.1 2.70 1 1 12.45 20 0.0 0.0 GEH/GEV060 460/60/3 16.0 7.8 52.0 1 12.1 2.70 1 1 20.01 25 10.6 13.3 GEH/GEV060 575/60/3 8.0 5.8 38.9 1 9.1 2.20 1 1 9.45 15 0.0 0.0 74 WSHP-SVX01N-EN Electrical Data Table 48. Electrical data - high static motors - ½ to 5 tons GEH*/GEV* Model No. Volts Maximum Total Comp Comp Blower Blower Fan Minimum Overcurrent Electric Electric Unit RLA LRA No. of Cmp Motor Motor Motor Circuit Protective Heat Heat FLA (ea) (ea) Comp. MCC FLA hp Num. Ampacity Device kW Amps GEHE/GEVE GEH/GEV006 115/60/1 6.8 5.6 30.0 1 7.5 1.20 1/12 1 8.20 15 0.0 0.0 GEH/GEV006 208/60/1 3.9 3.3 14.0 1 4.2 0.60 1/12 1 4.73 15 0.0 0.0 GEH/GEV006 208/60/1 4.5 3.3 14.0 1 4.2 0.60 1/12 1 5.68 15 0.8 3.9 GEH/GEV006 230/60/1 3.8 3.2 15.0 1 4.2 0.60 1/12 1 4.60 15 0.0 0.0 GEH/GEV006 230/60/1 4.9 3.2 15.0 1 4.2 0.60 1/12 1 6.18 15 1.0 4.3 GEH/GEV006 220-240/50/1 3.4 2.9 17.0 1 4.0 0.52 1/12 1 4.15 15 0.0 0.0 GEH/GEV006 220-240/50/1 7.4 2.9 17.0 1 4.0 0.52 1/12 1 9.19 15 1.6 6.8 GEH/GEV006 265/60/1 3.0 2.5 11.0 1 3.5 0.52 1/12 1 3.65 15 0.0 0.0 GEH/GEV006 265/60/1 5.5 2.5 11.0 1 3.5 0.52 1/12 1 6.92 15 1.3 5.0 GEH/GEV009 115/60/1 7.6 6.4 36.0 1 8.6 1.20 1/12 1 9.20 15 0.0 0.0 GEH/GEV009 208/60/1 4.3 3.7 16.0 1 4.8 0.60 1/12 1 5.23 15 0.0 0.0 GEH/GEV009 208/60/1 6.5 3.7 16.0 1 4.8 0.60 1/12 1 8.14 15 1.2 5.9 GEH/GEV009 230/60/1 4.1 3.5 17.0 1 4.8 0.60 1/12 1 4.98 15 0.0 0.0 GEH/GEV009 230/60/1 7.1 3.5 17.0 1 4.8 0.60 1/12 1 8.90 15 1.5 6.5 GEH/GEV009 220-240/50/1 6.0 5.3 23.0 1 7.4 0.72 1/8 1 7.35 15 0.0 0.0 GEH/GEV009 220-240/50/1 9.8 5.3 23.0 1 7.4 0.72 1/8 1 12.20 15 2.2 9.0 GEH/GEV009 265/60/1 3.3 2.8 13.0 1 3.7 0.52 1/12 1 4.02 15 0.0 0.0 GEH/GEV009 265/60/1 8.1 2.8 13.0 1 3.7 0.52 1/12 1 10.08 15 2.0 7.5 GEH/GEV012 115/60/1 13.7 12.1 58.0 1 16.9 1.57 1/8 1 16.70 25 0.0 0.0 GEH/GEV012 208/60/1 7.0 6.3 30.0 1 8.8 0.70 1/8 1 8.58 15 0.0 0.0 GEH/GEV012 208/60/1 8.5 6.3 27.0 1 8.8 0.70 1/8 1 10.67 15 1.6 7.8 GEH/GEV012 230/60/1 7.0 6.3 30.0 1 8.8 0.70 1/8 1 8.58 15 0.0 0.0 GEH/GEV012 230/60/1 9.4 6.3 30.0 1 8.8 0.70 1/8 1 11.74 15 2.0 8.7 GEH/GEV012 220-240/50/1 7.4 6.7 30.0 1 9.4 0.72 1/8 1 9.10 15 0.0 0.0 GEH/GEV012 220-240/50/1 12.0 6.7 30.0 1 9.4 0.72 1/8 1 14.96 15 2.7 11.3 GEH/GEV012 265/60/1 5.7 5.0 23.0 1 7.0 0.72 1/8 1 6.97 15 0.0 0.0 GEH/GEV012 265/60/1 10.7 5.0 23.0 1 7.0 0.72 1/8 1 13.40 15 2.7 10.0 GEH/GEV015 208/60/1 8.6 7.9 36.0 1 11.1 0.70 1/8 1 10.58 15 0.0 0.0 GEH/GEV015 208/60/1 10.3 7.9 36.0 1 11.1 0.70 1/8 1 12.89 15 2.0 9.6 GEH/GEV015 230/60/1 8.6 7.9 36.0 1 11.1 0.70 1/8 1 10.58 15 0.0 0.0 GEH/GEV015 230/60/1 11.6 7.9 36.0 1 11.1 0.70 1/8 1 14.46 15 2.5 10.9 GEH/GEV015 220-240/50/1 9.7 8.2 36.0 1 11.5 1.53 1/3 1 11.78 15 0.0 0.0 GEH/GEV015 220-240/50/1 15.2 8.2 36.0 1 11.5 1.53 1/3 1 19.00 20 3.3 13.7 GEH/GEV015 265/60/1 7.1 6.4 30.0 1 9.0 0.72 1/8 1 8.72 15 0.0 0.0 GEH/GEV015 265/60/1 13.2 6.4 30.0 1 9.0 0.72 1/8 1 16.47 20 3.3 12.5 GEH/GEV018 208/60/1 11.7 9.6 42.0 1 13.4 2.10 1/3 1 14.10 20 0.0 0.0 GEH/GEV018 208/60/1 13.9 9.6 42.0 1 13.4 2.10 1/3 1 17.41 20 2.5 11.8 GEH/GEV018 230/60/1 11.7 9.6 42.0 1 13.4 2.10 1/3 1 14.10 20 0.0 0.0 GEH/GEV018 230/60/1 15.1 9.6 42.0 1 13.4 2.10 1/3 1 18.93 20 3.0 13.0 GEH/GEV018 220-240/50/1 11.1 9.6 54.0 1 15.0 1.53 1/3 1 13.53 20 0.0 0.0 GEH/GEV018 220-240/50/1 19.7 9.6 54.0 1 15.0 1.53 1/3 1 24.57 25 4.4 18.1 GEH/GEV018 265/60/1 9.2 7.7 35.0 1 10.8 1.53 1/3 1 11.16 15 0.0 0.0 continued on next page WSHP-SVX01N-EN 75 Electrical Data Table 48. Electrical data - high static motors - ½ to 5 tons GEH*/GEV* (continued) Maximum Total Comp Comp Blower Blower Fan Minimum Overcurrent Electric Electric Unit RLA LRA No. of Cmp Motor Motor Motor Circuit Protective Heat Heat FLA (ea) (ea) Comp. MCC FLA hp Num. Ampacity Device kW Amps Model No. Volts GEH/GEV018 265/60/1 16.6 7.7 35.0 1 10.8 1.53 1/3 1 20.78 25 4.0 15.1 GEH/GEV018 380-415/50/3 5.2 4.2 28.0 1 6.5 0.95 1/3 1 6.20 15 0.0 0.0 GEH/GEV018 380-415/50/3 7.0 3.6 28.0 1 5.6 0.95 1/3 1 8.75 15 4.4 6.1 GEH/GEV024 208/60/1 14.9 12.8 58.3 1 20.0 2.10 1/3 1 18.10 30 0.0 0.0 GEH/GEV024 208/60/1 17.8 12.8 58.3 1 20.0 2.10 1/3 1 22.22 30 3.3 15.7 GEH/GEV024 230/60/1 14.9 12.8 58.3 1 20.0 2.10 1/3 1 18.10 30 0.0 0.0 GEH/GEV024 230/60/1 19.5 12.8 58.3 1 20.0 2.10 1/3 1 24.36 30 4.0 17.4 GEH/GEV024 220-240/50/1 12.7 11.2 60.0 1 17.5 1.53 1/3 1 15.53 25 0.0 0.0 GEH/GEV024 220-240/50/1 24.0 11.2 60.0 1 17.5 1.53 1/3 1 30.04 35 5.4 22.5 GEH/GEV024 265/60/1 11.1 9.6 54.0 1 15.0 1.53 1/3 1 13.53 20 0.0 0.0 GEH/GEV024 265/60/1 21.5 9.6 54.0 1 15.0 1.53 1/3 1 26.91 30 5.3 20.0 GEH/GEV024 208/60/3 9.2 7.7 53.7 1 12.0 1.53 1/3 1 11.16 15 0.0 0.0 GEH/GEV024 208/60/3 10.6 7.7 53.7 1 12.0 1.53 1/3 1 13.22 15 3.3 9.0 GEH/GEV024 230/60/3 9.8 7.7 53.7 1 12.0 2.10 1/3 1 11.73 15 0.0 0.0 GEH/GEV024 230/60/3 12.1 7.7 53.7 1 12.0 2.10 1/3 1 15.18 20 4.0 10.0 GEH/GEV024 380-415/50/3 5.2 4.2 28.0 1 6.5 0.95 1/3 1 6.20 15 0.0 0.0 GEH/GEV024 380-415/50/3 8.5 4.2 28.0 1 6.5 0.95 1/3 1 10.58 15 5.4 7.5 GEH/GEV024 460/60/3 4.6 3.6 28.0 1 5.6 0.95 1/3 1 5.45 15 0.0 0.0 GEH/GEV024 460/60/3 7.6 3.6 28.0 1 5.6 0.95 1/3 1 9.50 15 5.3 6.7 GEH/GEV030 208/60/1 16.2 14.1 73.0 1 22.0 2.10 1/3 1 19.73 30 0.0 0.0 GEH/GEV030 208/60/1 21.8 14.1 73.0 1 22.0 2.10 1/3 1 27.26 30 4.1 19.7 GEH/GEV030 230/60/1 16.2 14.1 73.0 1 22.0 2.10 1/3 1 19.73 30 0.0 0.0 GEH/GEV030 230/60/1 23.8 14.1 73.0 1 22.0 2.10 1/3 1 29.80 30 5.0 21.7 GEH/GEV030 220-240/50/1 19.5 16.7 79.0 1 26.0 2.77 1/2 1 23.65 40 0.0 0.0 GEH/GEV030 220-240/50/1 29.9 13.5 72.0 1 21.0 2.77 1/2 1 37.42 40 6.5 27.2 GEH/GEV030 265/60/1 12.7 11.2 60.0 1 17.5 1.53 1/3 1 15.53 25 0.0 0.0 GEH/GEV030 265/60/1 26.4 11.2 60.0 1 17.5 1.53 1/3 1 33.04 35 6.6 24.9 GEH/GEV030 208/60/3 11.0 8.9 58.0 1 13.9 2.10 1/3 1 13.23 20 0.0 0.0 GEH/GEV030 208/60/3 13.5 8.9 58.0 1 13.9 2.10 1/3 1 16.85 20 4.1 11.4 GEH/GEV030 230/60/3 11.0 8.9 58.0 1 13.9 2.10 1/3 1 13.23 20 0.0 0.0 GEH/GEV030 230/60/3 14.7 8.9 58.0 1 13.9 2.10 1/3 1 18.31 20 5.0 12.6 GEH/GEV030 380-415/50/3 7.5 5.8 38.0 1 9.0 1.70 1/2 1 8.95 15 0.0 0.0 GEH/GEV030 380-415/50/3 10.8 5.8 38.0 1 9.0 1.70 1/2 1 13.46 15 6.5 9.1 GEH/GEV030 460/60/3 5.2 4.2 28.0 1 6.5 0.95 1/3 1 6.20 15 0.0 0.0 GEH/GEV030 460/60/3 9.2 4.2 28.0 1 6.5 0.95 1/3 1 11.54 15 6.6 8.3 GEH/GEV036 208/60/1 20.3 16.7 79.0 1 26.0 3.60 1/2 1 24.48 40 0.0 0.0 GEH/GEV036 208/60/1 27.2 16.7 79.0 1 26.0 3.60 1/2 1 33.95 40 4.9 23.6 GEH/GEV036 230/60/1 20.3 16.7 79.0 1 26.0 3.60 1/2 1 24.48 40 0.0 0.0 GEH/GEV036 230/60/1 29.7 16.7 79.0 1 26.0 3.60 1/2 1 37.11 40 6.0 26.1 GEH/GEV036 265/60/1 16.3 13.5 72.0 1 21.0 2.77 1/2 1 19.65 30 0.0 0.0 GEH/GEV036 265/60/1 32.8 13.5 72.0 1 21.0 2.77 1/2 1 40.96 45 8.0 30.0 GEH/GEV036 208/60/3 14.0 10.4 73.0 1 16.3 3.60 1/2 1 16.60 25 0.0 0.0 GEH/GEV036 208/60/3 17.2 10.4 73.0 1 16.3 3.60 1/2 1 21.50 25 4.9 13.6 GEH/GEV036 230/60/3 14.0 10.4 73.0 1 16.3 3.60 1/2 1 16.60 25 0.0 0.0 continued on next page 76 WSHP-SVX01N-EN Electrical Data Table 48. Electrical data - high static motors - ½ to 5 tons GEH*/GEV* (continued) Model No. Volts GEH/GEV036 230/60/3 GEH/GEV036 GEH/GEV036 Maximum Total Comp Comp Blower Blower Fan Minimum Overcurrent Electric Electric Unit RLA LRA No. of Cmp Motor Motor Motor Circuit Protective Heat Heat FLA (ea) (ea) Comp. MCC FLA hp Num. Ampacity Device kW Amps 18.7 10.4 73.0 1 16.3 3.60 1/2 1 23.33 25 6.0 15.1 380-415/50/3 7.7 6.0 44.0 1 9.3 1.70 1/2 380-415/50/3 11.6 6.0 44.0 1 9.3 1.70 1/2 1 9.20 15 0.0 0.0 1 14.56 15 7.2 GEH/GEV036 460/60/3 7.5 5.8 38.0 1 9.0 1.70 9.9 1/2 1 8.95 15 0.0 0.0 GEH/GEV036 460/60/3 11.7 5.8 38.0 1 9.0 1.70 1/2 1 14.60 15 8.0 10.0 GEH/GEV042 208/60/1 21.5 17.9 112.0 1 GEH/GEV042 208/60/1 31.0 17.9 112.0 1 28.0 3.60 1/2 1 25.98 40 0.0 0.0 28.0 3.60 1/2 1 38.75 40 5.7 27.4 GEH/GEV042 230/60/1 21.5 17.9 112.0 GEH/GEV042 230/60/1 34.0 17.9 112.0 1 28.0 3.60 1/2 1 25.98 40 0.0 0.0 1 28.0 3.60 1/2 1 42.54 45 7.0 30.4 GEH/GEV042 208/60/3 17.1 13.5 GEH/GEV042 208/60/3 19.4 13.5 88.0 1 21.1 3.60 1/2 1 20.48 30 0.0 0.0 88.0 1 21.1 3.60 1/2 1 24.28 30 5.7 15.8 GEH/GEV042 230/60/3 17.1 GEH/GEV042 230/60/3 21.2 13.5 88.0 1 21.1 3.60 1/2 1 20.48 30 0.0 0.0 13.5 88.0 1 21.1 3.60 1/2 1 26.46 30 7.0 17.6 GEH/GEV042 380-415/50/3 GEH/GEV042 380-415/50/3 9.0 6.3 55.0 1 9.9 2.70 1 1 10.58 15 0.0 0.0 14.7 6.3 55.0 1 9.9 2.70 1 1 18.33 20 8.6 12.0 GEH/GEV042 460/60/3 GEH/GEV042 460/60/3 7.7 6.0 44.0 1 9.3 1.70 1/2 1 9.20 15 0.0 0.0 13.4 6.0 44.0 1 9.3 1.70 1/2 1 16.72 20 9.3 11.7 GEH/GEV042 575/60/3 6.2 GEH/GEV048 208/60/1 26.8 4.9 34.0 1 7.7 1.31 1/2 1 7.44 15 0.0 0.0 21.4 135.0 1 33.4 5.40 1 1 32.15 50 0.0 GEH/GEV048 208/60/1 36.7 0.0 21.4 135.0 1 33.4 5.40 1 1 45.81 50 6.5 31.3 GEH/GEV048 230/60/1 26.8 21.4 135.0 1 33.4 5.40 1 1 32.15 50 0.0 0.0 GEH/GEV048 GEH/GEV048 230/60/1 40.2 21.4 135.0 1 33.4 5.40 1 1 50.23 60 8.0 34.8 208/60/3 19.9 14.5 98.0 1 22.6 5.40 1 1 23.53 35 0.0 0.0 GEH/GEV048 208/60/3 23.4 14.5 98.0 1 22.6 5.40 1 1 29.30 35 6.5 18.0 GEH/GEV048 230/60/3 19.9 14.5 98.0 1 22.6 5.40 1 1 23.53 35 0.0 0.0 GEH/GEV048 230/60/3 25.5 14.5 98.0 1 22.6 5.40 1 1 31.85 35 8.0 20.1 GEH/GEV048 380-415/50/3 10.5 7.8 52.0 1 12.1 2.70 1 1 12.45 20 0.0 0.0 GEH/GEV048 380-415/50/3 14.7 7.8 52.0 1 12.1 2.70 1 1 18.33 20 8.6 12.0 GEH/GEV048 460/60/3 9.0 6.3 55.0 1 9.9 2.70 1 1 10.58 15 0.0 0.0 GEH/GEV048 460/60/3 16.0 6.3 55.0 1 9.9 2.70 1 1 20.01 25 10.6 13.3 GEH/GEV048 575/60/3 8.2 6.0 41.0 1 9.4 2.20 1 1 9.70 15 0.0 0.0 GEH/GEV060 208/60/1 31.7 26.3 134.0 1 41.0 5.40 1 1 38.28 60 0.0 0.0 GEH/GEV060 208/60/1 36.7 26.3 134.0 1 41.0 5.40 1 1 45.81 60 6.5 31.3 GEH/GEV060 230/60/1 31.7 26.3 134.0 1 41.0 5.40 1 1 38.28 60 0.0 0.0 GEH/GEV060 230/60/1 40.2 26.3 134.0 1 41.0 5.40 1 1 50.23 60 8.0 34.8 GEH/GEV060 208/60/3 21.0 15.6 110.0 1 24.4 5.40 1 1 24.90 40 0.0 0.0 GEH/GEV060 208/60/3 23.4 15.6 110.0 1 24.4 5.40 1 1 29.30 40 6.5 18.0 GEH/GEV060 230/60/3 21.0 15.6 110.0 1 24.4 5.40 1 1 24.90 40 0.0 0.0 GEH/GEV060 230/60/3 25.5 15.6 110.0 1 24.4 5.40 1 1 31.85 40 8.0 20.1 GEH/GEV060 380-415/50/3 12.3 9.6 75.0 1 15.0 2.70 1 1 14.70 20 0.0 0.0 GEH/GEV060 380-415/50/3 14.7 9.6 75.0 1 15.0 2.70 1 1 18.33 20 8.6 12.0 GEH/GEV060 460/60/3 10.5 7.8 52.0 1 12.1 2.70 1 1 12.45 20 0.0 0.0 GEH/GEV060 460/60/3 16.0 7.8 52.0 1 12.1 2.70 1 1 20.01 25 10.6 13.3 GEH/GEV060 575/60/3 8.0 5.8 38.9 1 9.1 2.20 1 1 9.45 15 0.0 0.0 WSHP-SVX01N-EN 77 Electrical Data Table 49. Electrical data - ECM motors - ½ to 6 tons EXH*/EXV* Maximum Overcurrent Protective Device Model No. Volts Total Unit FLA EXH006 208/60/1 3.70 3.3 14.0 0.40 1/3 4.53 15 0.0 0.0 EXH006 208/60/1 4.34 3.3 14.0 0.40 1/3 5.43 15 0.8 3.9 EXH006 230/60/1 3.60 3.2 15.0 0.40 1/3 4.40 15 0.0 0.0 EXH006 230/60/1 4.75 3.2 15.0 0.40 1/3 5.93 15 1.0 4.3 EXH006 265/60/1 2.90 2.5 11.0 0.40 1/3 3.53 15 0.0 0.0 EXH006 265/60/1 5.42 2.5 11.0 0.40 1/3 6.77 15 1.3 5.0 EXH009 208/60/1 4.30 3.7 16.0 0.60 1/3 5.23 15 0.0 0.0 EXH009 208/60/1 6.51 3.7 16.0 0.60 1/3 8.14 15 1.2 5.9 EXH009 230/60/1 4.10 3.5 17.0 0.60 1/3 4.98 15 0.0 0.0 EXH009 230/60/1 7.12 3.5 17.0 0.60 1/3 8.90 15 1.5 6.5 EXH009 265/60/1 3.40 2.8 13.0 0.60 1/3 4.10 15 0.0 0.0 EXH009 265/60/1 8.15 2.8 13.0 0.60 1/3 10.18 15 2.0 7.5 EXH012 208/60/1 7.02 6.3 30.0 0.72 1/3 8.60 15 0.0 0.0 EXH012 208/60/1 8.56 6.3 27.0 0.72 1/3 10.70 15 1.6 7.8 EXH012 230/60/1 7.02 6.3 30.0 0.72 1/3 8.60 15 0.0 0.0 EXH012 230/60/1 9.42 6.3 30.0 0.72 1/3 11.77 15 2.0 8.7 EXH012 265/60/1 5.72 5.0 23.0 0.72 1/3 6.97 15 0.0 0.0 EXH012 265/60/1 10.72 5.0 23.0 0.72 1/3 13.40 15 2.7 10.0 EXH015 208/60/1 8.79 7.9 36.0 0.89 1/3 10.77 15 0.0 0.0 EXH015 208/60/1 10.51 7.9 36.0 0.89 1/3 13.13 15 2.0 9.6 EXH015 230/60/1 8.79 7.9 36.0 0.89 1/3 10.77 15 0.0 0.0 EXH015 230/60/1 11.76 7.9 36.0 0.89 1/3 14.70 15 2.5 10.9 EXH015 265/60/1 7.29 6.4 30.0 0.89 1/3 8.89 15 0.0 0.0 EXH015 265/60/1 13.34 6.4 30.0 0.89 1/3 16.68 20 3.3 12.5 EXH018 208/60/1 11.10 9.6 42.0 1.50 1/2 13.50 20 0.0 0.0 EXH018 208/60/1 13.33 9.6 42.0 1.50 1/2 16.66 20 2.5 11.8 EXH018 230/60/1 11.10 9.6 42.0 1.50 1/2 13.50 20 0.0 0.0 EXH018 230/60/1 14.54 9.6 42.0 1.50 1/2 18.18 20 3.0 13.0 EXH018 265/60/1 9.00 7.7 35.0 1.30 1/2 10.93 15 0.0 0.0 EXH018 265/60/1 16.39 7.7 35.0 1.30 1/2 20.49 25 4.0 15.1 EXH024 208/60/1 15.70 13.5 58.3 2.20 1/2 19.08 30 0.0 0.0 EXH024 208/60/1 17.87 13.5 58.3 2.20 1/2 22.34 30 3.3 15.7 EXH024 230/60/1 15.70 13.5 58.3 2.20 1/2 19.08 30 0.0 0.0 EXH024 230/60/1 19.59 13.5 58.3 2.20 1/2 24.49 30 4.0 17.4 EXH024 265/60/1 10.10 9.0 54.0 1.10 1/2 12.35 20 0.0 0.0 EXH024 265/60/1 21.10 9.0 54.0 1.10 1/2 26.38 30 5.3 20.0 EXH030 208/60/1 17.30 14.1 77.0 3.20 1/2 20.83 30 0.0 0.0 EXH030 208/60/1 26.76 14.1 77.0 3.20 1/2 33.45 35 4.9 23.6 EXH030 230/60/1 17.30 14.1 77.0 3.20 1/2 20.83 30 0.0 0.0 EXH030 230/60/1 29.29 14.1 77.0 3.20 1/2 36.61 40 6.0 26.1 EXH030 265/60/1 13.70 10.9 60.0 2.80 1/2 16.43 25 0.0 0.0 EXH030 265/60/1 32.80 10.9 60.0 2.80 1/2 41.00 45 8.0 30.0 Comp RLA (ea) Comp LRA (ea) Blower Motor FLA Blower Motor hp Minimum Circuit Ampacity Electric Electric Heat kW Heat Amps EXH - Horizontal Units continued on next page 78 WSHP-SVX01N-EN Electrical Data Table 49. Electrical data - ECM motors - ½ to 6 tons EXH*/EXV* (continued) Maximum Overcurrent Protective Device Model No. Volts Total Unit FLA EXH036 208/60/1 18.10 14.1 77.0 4.00 3/4 21.63 35 0.0 0.0 EXH036 208/60/1 27.56 14.1 77.0 4.00 3/4 34.45 35 4.9 23.6 EXH036 230/60/1 18.10 14.1 77.0 4.00 3/4 21.63 35 0.0 0.0 EXH036 230/60/1 30.09 14.1 77.0 4.00 3/4 37.61 40 6.0 26.1 EXH036 265/60/1 15.70 12.2 72.0 3.50 3/4 18.75 30 0.0 0.0 EXH036 265/60/1 33.50 12.2 72.0 3.50 3/4 41.88 45 8.0 30.0 EXH036 208/60/3 13.00 9.0 71.0 4.00 3/4 15.25 20 0.0 0.0 EXH036 208/60/3 17.60 9.0 71.0 4.00 3/4 22.00 25 4.9 13.6 EXH036 230/60/3 13.00 9.0 71.0 4.00 3/4 15.25 20 0.0 0.0 EXH036 230/60/3 19.06 9.0 71.0 4.00 3/4 23.83 25 6.0 15.1 EXH036 460/60/3 9.10 5.6 38.0 3.50 3/4 10.50 15 0.0 0.0 EXH036 460/60/3 13.48 5.6 38.0 3.50 3/4 16.85 20 8.0 10.0 EXH042 208/60/1 22.30 17.9 112.0 4.40 3/4 26.78 40 0.0 0.0 EXH042 208/60/1 35.65 17.9 112.0 4.40 3/4 44.56 45 6.5 31.3 EXH042 230/60/1 22.30 17.9 112.0 4.40 3/4 26.78 40 0.0 0.0 34.8 Comp RLA (ea) Comp LRA (ea) Blower Motor FLA Blower Motor hp Minimum Circuit Ampacity Electric Electric Heat kW Heat Amps EXH - Horizontal Units EXH042 230/60/1 39.18 17.9 112.0 4.40 3/4 48.98 50 8.0 EXH042 208/60/3 17.60 13.2 88.0 4.40 3/4 20.90 30 0.0 0.0 EXH042 208/60/3 22.44 13.2 88.0 4.40 3/4 28.05 30 6.5 18.0 EXH042 230/60/3 17.60 13.2 88.0 4.40 3/4 20.90 30 0.0 0.0 EXH042 230/60/3 24.48 13.2 88.0 4.40 3/4 30.60 35 8.0 20.1 EXH042 460/60/3 9.80 6.0 44.0 3.80 3/4 11.30 15 0.0 0.0 EXH042 460/60/3 17.10 6.0 44.0 3.80 3/4 21.38 25 10.6 13.3 EXH048 208/60/1 25.00 19.9 109.0 5.10 3/4 29.98 45 0.0 0.0 31.3 EXH048 208/60/1 36.35 19.9 109.0 5.10 3/4 45.44 50 6.5 EXH048 230/60/1 25.00 19.9 109.0 5.10 3/4 29.98 45 0.0 0.0 EXH048 230/60/1 39.88 19.9 109.0 5.10 3/4 49.85 50 8.0 34.8 EXH048 208/60/3 18.20 13.1 83.1 5.10 3/4 21.48 30 0.0 0.0 EXH048 208/60/3 23.14 13.1 83.1 5.10 3/4 28.93 30 6.5 18.0 EXH048 230/60/3 18.20 13.1 83.1 5.10 3/4 21.48 30 0.0 0.0 EXH048 230/60/3 25.18 13.1 83.1 5.10 3/4 31.48 35 8.0 20.1 EXH048 460/60/3 10.50 6.1 41.0 4.40 3/4 12.03 15 0.0 0.0 EXH048 460/60/3 17.70 6.1 41.0 4.40 3/4 22.13 25 10.6 13.3 EXH060 208/60/1 34.40 26.4 134.0 8.00 1 41.00 60 0.0 0.0 EXH060 208/60/1 39.25 26.4 134.0 8.00 1 49.06 60 6.5 31.3 EXH060 230/60/1 34.40 26.4 134.0 8.00 1 41.00 60 0.0 0.0 34.8 EXH060 230/60/1 42.78 26.4 134.0 8.00 1 53.48 60 8.0 EXH060 208/60/3 24.00 16.0 110.0 8.00 1 28.00 40 0.0 0.0 EXH060 208/60/3 26.04 16.0 110.0 8.00 1 32.55 40 6.5 18.0 EXH060 230/60/3 24.00 16.0 110.0 8.00 1 28.00 40 0.0 0.0 20.1 EXH060 230/60/3 28.08 16.0 110.0 8.00 1 35.10 40 8.0 EXH060 460/60/3 14.70 7.8 52.0 6.90 1 16.65 20 0.0 0.0 EXH060 460/60/3 20.20 7.8 52.0 6.90 1 25.26 30 10.6 13.3 EXH070 208/60/1 37.10 30.1 158.0 7.00 1 44.63 70 0.0 0.0 continued on next page WSHP-SVX01N-EN 79 Electrical Data Table 49. Electrical data - ECM motors - ½ to 6 tons EXH*/EXV* (continued) Maximum Overcurrent Protective Device Model No. Volts Total Unit FLA EXH070 208/60/1 38.25 30.1 158.0 7.00 1 47.81 70 6.5 EXH070 230/60/1 37.10 30.1 158.0 7.00 1 44.63 70 0.0 0.0 EXH070 230/60/1 41.78 30.1 158.0 7.00 1 52.23 70 8.0 34.8 Comp RLA (ea) Comp LRA (ea) Blower Motor FLA Blower Motor hp Minimum Circuit Ampacity Electric Electric Heat kW Heat Amps EXH - Horizontal Units 31.3 EXH070 208/60/3 27.50 20.5 155.0 7.00 1 32.63 50 0.0 0.0 EXH070 208/60/3 27.50 20.5 155.0 7.00 1 32.63 50 6.5 18.0 EXH070 230/60/3 27.50 20.5 155.0 7.00 1 32.63 50 0.0 0.0 EXH070 230/60/3 27.50 20.5 155.0 7.00 1 33.85 50 8.0 20.1 EXH070 460/60/3 15.70 9.6 75.0 6.10 1 18.10 25 0.0 0.0 EXH070 460/60/3 19.40 9.6 75.0 6.10 1 24.26 25 10.6 13.3 EXV006 208/60/1 3.76 3.3 14.0 4.59 15 0.0 0.0 EXV - Vertical Units 0.46 1/3 EXV006 208/60/1 4.40 3.3 14.0 0.46 1/3 5.50 15 0.8 3.9 EXV006 230/60/1 3.66 3.2 15.0 0.46 1/3 4.46 15 0.0 0.0 EXV006 230/60/1 4.81 3.2 15.0 0.46 1/3 6.01 15 1.0 4.3 EXV006 265/60/1 2.96 2.5 11.0 0.46 1/3 3.59 15 0.0 0.0 EXV006 265/60/1 5.48 2.5 11.0 0.46 1/3 6.85 15 1.3 5.0 EXV009 208/60/1 4.31 3.7 16.0 0.61 1/3 5.24 15 0.0 0.0 EXV009 208/60/1 6.52 3.7 16.0 0.61 1/3 8.15 15 1.2 5.9 EXV009 230/60/1 4.11 3.5 17.0 0.61 1/3 4.99 15 0.0 0.0 EXV009 230/60/1 7.13 3.5 17.0 0.61 1/3 8.91 15 1.5 6.5 EXV009 265/60/1 3.41 2.8 13.0 0.61 1/3 4.11 15 0.0 0.0 EXV009 265/60/1 8.16 2.8 13.0 0.61 1/3 10.20 15 2.0 7.5 EXV012 208/60/1 6.91 6.3 30.0 0.61 1/3 8.49 15 0.0 0.0 EXV012 208/60/1 8.45 6.3 27.0 0.61 1/3 10.56 15 1.6 7.8 EXV012 230/60/1 6.91 6.3 30.0 0.61 1/3 8.49 15 0.0 0.0 EXV012 230/60/1 9.31 6.3 30.0 0.61 1/3 11.63 15 2.0 8.7 EXV012 265/60/1 5.61 5.0 23.0 0.61 1/3 6.86 15 0.0 0.0 EXV012 265/60/1 10.61 5.0 23.0 0.61 1/3 13.26 15 2.7 10.0 EXV015 208/60/1 8.73 7.9 36.0 0.83 1/3 10.71 15 0.0 0.0 EXV015 208/60/1 10.45 7.9 36.0 0.83 1/3 13.06 15 2.0 9.6 EXV015 230/60/1 8.73 7.9 36.0 0.83 1/3 10.71 15 0.0 0.0 EXV015 230/60/1 11.70 7.9 36.0 0.83 1/3 14.62 15 2.5 10.9 EXV015 265/60/1 7.23 6.4 30.0 0.83 1/3 8.83 15 0.0 0.0 EXV015 265/60/1 13.28 6.4 30.0 0.83 1/3 16.60 20 3.3 12.5 EXV018 208/60/1 11.10 9.6 42.0 1.50 1/2 13.50 20 0.0 0.0 EXV018 208/60/1 13.33 9.6 42.0 1.50 1/2 16.66 20 2.5 11.8 EXV018 230/60/1 11.10 9.6 42.0 1.50 1/2 13.50 20 0.0 0.0 EXV018 230/60/1 14.54 9.6 42.0 1.50 1/2 18.18 20 3.0 13.0 EXV018 265/60/1 9.00 7.7 35.0 1.30 1/2 10.93 15 0.0 0.0 EXV018 265/60/1 16.39 7.7 35.0 1.30 1/2 20.49 25 4.0 15.1 EXV024 208/60/1 15.70 13.5 58.3 2.20 1/2 19.08 30 0.0 0.0 EXV024 208/60/1 17.87 13.5 58.3 2.20 1/2 22.34 30 3.3 15.7 EXV024 230/60/1 15.70 13.5 58.3 2.20 1/2 19.08 30 0.0 0.0 continued on next page 80 WSHP-SVX01N-EN Electrical Data Table 49. Electrical data - ECM motors - ½ to 6 tons EXH*/EXV* (continued) Minimum Circuit Ampacity Maximum Overcurrent Protective Device Model No. Volts Total Unit FLA EXV024 230/60/1 19.59 13.5 58.3 2.20 1/2 24.49 30 4.0 EXV024 265/60/1 10.10 9.0 54.0 1.10 1/2 12.35 20 0.0 0.0 EXV024 265/60/1 21.10 9.0 54.0 1.10 1/2 26.38 30 5.3 20.0 EXV030 208/60/1 17.30 14.1 77.0 3.20 1/2 20.83 30 0.0 0.0 EXV030 208/60/1 26.76 14.1 77.0 3.20 1/2 33.45 35 4.9 23.6 EXV030 230/60/1 17.30 14.1 77.0 3.20 1/2 20.83 30 0.0 0.0 EXV030 230/60/1 29.29 14.1 77.0 3.20 1/2 36.61 40 6.0 26.1 EXV030 265/60/1 13.70 10.9 60.0 2.80 1/2 16.43 25 0.0 0.0 EXV030 265/60/1 32.80 10.9 60.0 2.80 1/2 41.00 45 8.0 30.0 EXV036 208/60/1 18.10 14.1 77.0 4.00 3/4 21.63 35 0.0 0.0 EXV036 208/60/1 27.56 14.1 77.0 4.00 3/4 34.45 35 4.9 23.6 EXV036 230/60/1 18.10 14.1 77.0 4.00 3/4 21.63 35 0.0 0.0 EXV036 230/60/1 30.09 14.1 77.0 4.00 3/4 37.61 40 6.0 26.1 EXV036 265/60/1 15.70 12.2 72.0 3.50 3/4 18.75 30 0.0 0.0 EXV036 265/60/1 33.50 12.2 72.0 3.50 3/4 41.88 45 8.0 30.0 EXV036 208/60/3 13.00 9.0 71.0 4.00 3/4 15.25 20 0.0 0.0 EXV036 208/60/3 17.60 9.0 71.0 4.00 3/4 22.00 25 4.9 13.6 EXV036 230/60/3 13.00 9.0 71.0 4.00 3/4 15.25 20 0.0 0.0 EXV036 230/60/3 19.06 9.0 71.0 4.00 3/4 23.83 25 6.0 15.1 EXV036 460/60/3 9.10 5.6 38.0 3.50 3/4 10.50 15 0.0 0.0 EXV036 460/60/3 13.48 5.6 38.0 3.50 3/4 16.85 20 8.0 10.0 Comp RLA (ea) Comp LRA (ea) Blower Motor FLA Blower Motor hp Electric Electric Heat kW Heat Amps EXV - Vertical Units 17.4 EXV042 208/60/1 22.30 17.9 112.0 4.40 3/4 26.78 40 0.0 0.0 EXV042 208/60/1 35.65 17.9 112.0 4.40 3/4 44.56 45 6.5 31.3 EXV042 230/60/1 22.30 17.9 112.0 4.40 3/4 26.78 40 0.0 0.0 EXV042 230/60/1 39.18 17.9 112.0 4.40 3/4 48.98 50 8.0 34.8 EXV042 208/60/3 17.60 13.2 88.0 4.40 3/4 20.90 30 0.0 0.0 EXV042 208/60/3 22.44 13.2 88.0 4.40 3/4 28.05 30 6.5 18.0 EXV042 230/60/3 17.60 13.2 88.0 4.40 3/4 20.90 30 0.0 0.0 EXV042 230/60/3 24.48 13.2 88.0 4.40 3/4 30.60 35 8.0 20.1 EXV042 460/60/3 9.80 6.0 44.0 3.80 3/4 11.30 15 0.0 0.0 EXV042 460/60/3 17.10 6.0 44.0 3.80 3/4 21.38 25 10.6 13.3 EXV048 208/60/1 25.00 19.9 109.0 5.10 3/4 29.98 45 0.0 0.0 EXV048 208/60/1 36.35 19.9 109.0 5.10 3/4 45.44 50 6.5 31.3 EXV048 230/60/1 25.00 19.9 109.0 5.10 3/4 29.98 45 0.0 0.0 EXV048 230/60/1 39.88 19.9 109.0 5.10 3/4 49.85 50 8.0 34.8 EXV048 208/60/3 18.20 13.1 83.1 5.10 3/4 21.48 30 0.0 0.0 EXV048 208/60/3 23.14 13.1 83.1 5.10 3/4 28.93 30 6.5 18.0 EXV048 230/60/3 18.20 13.1 83.1 5.10 3/4 21.48 30 0.0 0.0 EXV048 230/60/3 25.18 13.1 83.1 5.10 3/4 31.48 35 8.0 20.1 EXV048 460/60/3 10.50 6.1 41.0 4.40 3/4 12.03 15 0.0 0.0 EXV048 460/60/3 17.70 6.1 41.0 4.40 3/4 22.13 25 10.6 13.3 EXV060 208/60/1 34.40 26.4 134.0 8.00 1 41.00 60 0.0 0.0 EXV060 208/60/1 39.25 26.4 134.0 8.00 1 49.06 60 6.5 31.3 continued on next page WSHP-SVX01N-EN 81 Electrical Data Table 49. Electrical data - ECM motors - ½ to 6 tons EXH*/EXV* (continued) Maximum Overcurrent Protective Device Model No. Volts Total Unit FLA EXV060 230/60/1 34.40 26.4 134.0 8.00 1 41.00 60 0.0 0.0 EXV060 230/60/1 42.78 26.4 134.0 8.00 1 53.48 60 8.0 34.8 EXV060 208/60/3 24.00 16.0 110.0 8.00 1 28.00 40 0.0 0.0 18.0 Comp RLA (ea) Comp LRA (ea) Blower Motor FLA Blower Motor hp Minimum Circuit Ampacity Electric Electric Heat kW Heat Amps EXV - Vertical Units EXV060 208/60/3 26.04 16.0 110.0 8.00 1 32.55 40 6.5 EXV060 230/60/3 24.00 16.0 110.0 8.00 1 28.00 40 0.0 0.0 EXV060 230/60/3 28.08 16.0 110.0 8.00 1 35.10 40 8.0 20.1 EXV060 460/60/3 14.70 7.8 52.0 6.90 1 16.65 20 0.0 0.0 EXV060 460/60/3 20.20 7.8 52.0 6.90 1 25.26 30 10.6 13.3 EXV070 208/60/1 37.10 30.1 158.0 7.00 1 44.63 70 0.0 0.0 EXV070 208/60/1 38.25 30.1 158.0 7.00 1 47.81 70 6.5 31.3 EXV070 230/60/1 37.10 30.1 158.0 7.00 1 44.63 70 0.0 0.0 34.8 EXV070 230/60/1 41.78 30.1 158.0 7.00 1 52.23 70 8.0 EXV070 208/60/3 27.50 20.5 155.0 7.00 1 32.63 50 0.0 0.0 EXV070 208/60/3 27.50 20.5 155.0 7.00 1 32.63 50 6.5 18.0 EXV070 230/60/3 27.50 20.5 155.0 7.00 1 32.63 50 0.0 0.0 20.1 EXV070 230/60/3 27.50 20.5 155.0 7.00 1 33.85 50 8.0 EXV070 460/60/3 15.70 9.6 75.0 6.10 1 18.10 25 0.0 0.0 EXV070 460/60/3 19.40 9.6 75.0 6.10 1 24.26 25 10.6 13.3 Table 50. Electrical data: 6 to 25 tons - single speed blower motor Maximum Blower Blower Fan Minimum Overcurrent Motor Motor Motor Circuit Protective Cmp MCC FLA HP No. Ampacity Device Model No. Volts Total FLA Comp RLA (ea) Comp LRA (ea) GEH072 208/60/1 39.9 16.7 79 2 26 6.5 1.0 1 44.08 60 GEH072 230/60/1 39.9 16.7 79 2 26 6.5 1.0 1 44.08 60 GEH072 208/60/1 42.7 16.7 79 2 26 9.3 1.5 1 46.88 60 GEH072 230/60/1 42.3 16.7 79 2 26 8.9 1.5 1 46.48 60 GEH072 208/60/1 44.6 16.7 79 2 26 11.2 2.0 1 48.78 60 GEH072 230/60/1 43.6 16.7 79 2 26 10.2 2.0 1 47.78 60 GEH072 380-415/50/3 13.9 7.1/5.1 48/35 2 11/8 1.7 0.75 1 15.68 20 GEH072 208/60/3 24.3 10.4 73 2 16.3 3.5 1.0 1 26.90 35 GEH072 230/60/3 24.6 10.4 73 2 16.3 3.8 1.0 1 27.20 35 GEH072 460/60/3 13.4 5.8 38 2 9 1.8 1.0 1 14.85 20 GEH072 380-415/50/3 14.3 7.1/5.1 48/35 2 11/8 2.1 1.0 1 16.08 20 GEH072 208/60/3 26.4 10.4 73 2 16.3 5.6 1.5 1 29.00 35 GEH072 230/60/3 25.6 10.4 73 2 16.3 4.8 1.5 1 28.20 35 GEH072 380-415/50/3 15.2 7.1/5.1 48/35 2 11/8 3.0 1.5 1 16.98 20 GEH072 460/60/3 14.0 5.8 38 2 9 2.4 1.5 1 15.45 20 GEH072 208/60/3 27.9 10.4 73 2 16.3 7.1 2.0 1 30.50 40 GEH072 230/60/3 27.0 10.4 73 2 16.3 6.2 2.0 1 29.60 40 GEH072 380-415/50/3 15.6 7.1/5.1 48/35 2 11/8 3.4 2.0 1 17.38 20 No. of Comp. GEH - Horizontal Units continued on next page 82 WSHP-SVX01N-EN Electrical Data Table 50. Electrical data: 6 to 25 tons - single speed blower motor (continued) Maximum Blower Blower Fan Minimum Overcurrent Motor Motor Motor Circuit Protective Cmp MCC FLA HP No. Ampacity Device Model No. Volts Total FLA Comp RLA (ea) Comp LRA (ea) GEH072 460/60/3 14.7 5.8 38 2 9 3.1 2.0 1 16.15 20 GEH072 380-415/50/3 17.4 7.1/5.1 48/35 2 11/8 5.2 3.0 1 19.18 25 GEH090 208/60/3 28.4 14.5/10.4 98/73 2 22.6/16.3 3.5 1.0 1 32.03 45 GEH090 230/60/3 28.7 14.5/10.4 98/73 2 22.6/16.3 3.8 1.0 1 32.33 45 GEH090 460/60/3 13.9 6.3/5.8 55/38 2 9.9/9 1.8 1.0 1 15.48 20 GEH090 208/60/3 30.5 14.5/10.4 98/73 2 22.6/16.3 5.6 1.5 1 34.13 45 GEH090 230/60/3 29.7 14.5/10.4 98/73 2 22.6/16.3 4.8 1.5 1 33.33 45 GEH090 380-415/50/3 22.2 9.6 64 2 15 3.0 1.5 1 24.60 30 GEH090 460/60/3 14.5 6.3/5.8 55/38 2 9.9/9 2.4 1.5 1 16.08 20 GEH090 208/60/3 32.0 14.5/10.4 98/73 2 22.6/16.3 7.1 2.0 1 35.63 50 GEH090 230/60/3 31.1 14.5/10.4 98/73 2 22.6/16.3 6.2 2.0 1 34.73 45 GEH090 380-415/50/3 22.6 9.6 64 2 15 3.4 2.0 1 25.00 30 GEH090 460/60/3 15.2 6.3/5.8 55/38 2 9.9/9 3.1 2.0 1 16.78 20 GEH090 575/60/3 12.1 6/3.8 41/36.5 2 9.4/5.9 2.3 2.0 1 13.60 15 GEH090 208/60/3 34.3 14.5/10.4 98/73 2 22.6/16.3 9.4 3.0 1 37.93 50 GEH090 230/60/3 33.1 14.5/10.4 98/73 2 22.6/16.3 8.2 3.0 1 36.73 50 GEH090 380-415/50/3 24.4 9.6 64 2 15 5.2 3.0 1 26.80 35 GEH090 460/60/3 16.7 6.3 55 2 9.9 4.1 3.0 1 18.28 20 GEH090 575/60/3 13.1 6/3.8 41/36.5 2 9.4/5.9 3.3 3.0 1 14.60 20 GEH120 380-415/50/3 23.3 10.6 74 2 16.5 2.1 1.0 1 25.95 35 GEH120 208/60/3 37.6 16 110 2 24.9 5.6 1.5 1 41.60 50 GEH120 230/60/3 36.8 16 110 2 24.9 4.8 1.5 1 40.80 50 GEH120 380-415/50/3 24.2 10.6 74 2 16.5 3.0 1.5 1 26.85 35 GEH120 460/60/3 18.0 7.8 52 2 12.1 2.4 1.5 1 19.95 25 GEH120 208/60/3 39.1 16 110 2 24.9 7.1 2.0 1 43.10 50 GEH120 230/60/3 38.2 16 110 2 24.9 6.2 2.0 1 42.20 50 GEH120 380-415/50/3 24.6 10.6 74 2 16.5 3.4 2.0 1 27.25 35 GEH120 460/60/3 18.7 7.8 52 2 12.1 3.1 2.0 1 20.65 25 GEH120 575/60/3 13.7 5.7 38.9 2 8.9 2.3 2.0 1 15.13 20 GEH120 208/60/3 41.4 16 110 2 24.9 9.4 3.0 1 45.40 60 GEH120 230/60/3 40.2 16 110 2 24.9 8.2 3.0 1 44.20 60 GEH120 380-415/50/3 26.4 10.6 74 2 16.5 5.2 3.0 1 29.05 35 GEH120 460/60/3 19.7 7.8 52 2 12.1 4.1 3.0 1 21.65 25 GEH120 575/60/3 14.7 5.7 38.9 2 8.9 3.3 3.0 1 16.13 20 GEH120 208/60/3 46.0 16 110 2 24.9 14.0 5.0 1 50.00 60 GEH120 230/60/3 45.0 16 110 2 24.9 13.0 5.0 1 49.00 60 GEH120 460/60/3 22.1 7.8 52 2 12.1 6.5 5.0 1 24.05 30 GEH120 575/60/3 16.7 5.7 38.9 2 8.9 5.3 5.0 1 18.13 20 GEH150 208/60/3 50.4 22.4 149 2 35 5.6 1.5 1 56.00 70 No. of Comp. GEH - Horizontal Units GEH150 230/60/3 49.6 22.4 149 2 35 4.8 1.5 1 55.20 70 GEH150 380-415/50/3 27.4 12.2 101 2 19 3.0 1.5 1 30.45 40 GEH150 460/60/3 23.6 10.6 75 2 16.5 2.4 1.5 1 26.25 35 GEH150 575/60/3 17.3 7.7 54 2 12 1.9 1.5 1 19.23 25 continued on next page WSHP-SVX01N-EN 83 Electrical Data Table 50. Electrical data: 6 to 25 tons - single speed blower motor (continued) Maximum Blower Blower Fan Minimum Overcurrent Motor Motor Motor Circuit Protective Cmp MCC FLA HP No. Ampacity Device Model No. Volts Total FLA Comp RLA (ea) Comp LRA (ea) GEH150 208/60/3 51.9 22.4 149 2 35 7.1 2.0 1 57.50 70 GEH150 230/60/3 51.0 22.4 149 2 35 6.2 2.0 1 56.60 70 GEH150 380-415/50/3 27.8 12.2 101 2 19 3.4 2.0 1 30.85 40 GEH150 460/60/3 24.3 10.6 75 2 16.5 3.1 2.0 1 26.96 35 GEH150 575/60/3 17.7 7.7 54 2 12 2.3 2.0 1 19.63 25 GEH150 208/60/3 54.2 22.4 149 2 35 9.4 3.0 1 59.80 80 GEH150 230/60/3 53.0 22.4 149 2 35 8.2 3.0 1 58.60 80 40 No. of Comp. GEH - Horizontal Units GEH150 380-415/50/3 29.6 12.2 101 2 19 5.2 3.0 1 32.65 GEH150 460/60/3 25.3 10.6 75 2 16.5 4.1 3.0 1 27.95 35 GEH150 575/60/3 18.7 7.7 54 2 12 3.3 3.0 1 20.63 25 GEH150 208/60/3 58.8 22.4 149 2 35 14.0 5.0 1 64.40 80 GEH150 230/60/3 57.8 22.4 149 2 35 13.0 5.0 1 63.40 80 GEH150 380-415/50/3 32.6 12.2 101 2 19 8.2 5.0 1 35.65 45 GEH150 460/60/3 27.7 10.6 75 2 16.5 6.5 5.0 1 30.35 40 GEH150 575/60/3 20.7 7.7 54 2 12 5.3 5.0 1 22.63 30 GEH180 208/60/3 57.1 25 164 2 39 7.1 2.0 1 63.35 80 GEH180 230/60/3 56.2 25 164 2 39 6.2 2.0 1 62.45 80 GEH180 460/60/3 27.5 12.2 100 2 19 3.1 2.0 1 30.56 40 GEH180 575/60/3 20.3 9 78 2 14 2.3 2.0 1 22.55 30 GEH180 208/60/3 59.4 25 164 2 39 9.4 3.0 1 65.65 90 GEH180 230/60/3 58.2 25 164 2 39 8.2 3.0 1 64.45 80 GEH180 460/60/3 28.5 12.2 100 2 19 4.1 3.0 1 31.55 40 GEH180 575/60/3 21.3 9 78 2 14 3.3 3.0 1 23.55 30 GEH180 208/60/3 64.0 25 164 2 39 14.0 5.0 1 70.25 90 GEH180 230/60/3 63.0 25 164 2 39 13.0 5.0 1 69.25 90 GEH180 460/60/3 30.9 12.2 100 2 19 6.5 5.0 1 33.95 45 GEH180 575/60/3 23.3 9 78 2 14 5.3 5.0 1 25.55 30 GEH180 208/60/3 70.0 25 164 2 39 20.0 7.5 1 76.25 100 GEH180 230/60/3 69.4 25 164 2 39 19.4 7.5 1 75.65 100 GEH180 460/60/3 34.1 12.2 100 2 19 9.7 7.5 1 37.15 45 GEH180 575/60/3 26.0 9 78 2 14 8.0 7.5 1 28.25 35 GEV072 208/60/1 40.0 16.7 79 2 26 6.6 1.0 1 44.13 60 GEV072 230/60/1 39.9 16.7 79 2 26 6.5 1.0 1 44.08 60 GEV072 208/60/1 42.7 16.7 79 2 26 9.3 1.5 1 46.88 60 GEV072 230/60/1 42.3 16.7 79 2 26 8.9 1.5 1 46.48 60 GEV072 208/60/1 44.6 16.7 79 2 26 11.2 2.0 1 48.78 60 GEV072 230/60/1 43.6 16.7 79 2 26 10.2 2.0 1 47.81 60 GEV072 380-415/50/3 13.9 7.1/5.1 48/35 2 11/8 1.7 0.75 1 15.68 20 GEV072 208/60/3 24.3 10.4 73 2 16.3 3.5 1.0 1 26.90 35 GEV072 230/60/3 24.6 10.4 73 2 16.3 3.8 1.0 1 27.20 35 GEV072 460/60/3 13.4 5.8 38 2 9 1.8 1.0 1 14.85 20 GEV072 380-415/50/3 14.3 7.1/5.1 48/35 2 11/8 2.1 1.0 1 16.08 20 GEV - Vertical Units continued on next page 84 WSHP-SVX01N-EN Electrical Data Table 50. Electrical data: 6 to 25 tons - single speed blower motor (continued) Maximum Blower Blower Fan Minimum Overcurrent Motor Motor Motor Circuit Protective Cmp MCC FLA HP No. Ampacity Device Model No. Volts Total FLA Comp RLA (ea) Comp LRA (ea) GEV072 208/60/3 26.4 10.4 73 2 16.3 5.6 1.5 1 29.00 35 GEV072 230/60/3 25.6 10.4 73 2 16.3 4.8 1.5 1 28.20 35 GEV072 380-415/50/3 15.2 7.1/5.1 48/35 2 11/8 3.0 1.5 1 16.98 20 GEV072 460/60/3 14.0 5.8 38 2 9 2.4 1.5 1 15.45 20 GEV072 208/60/3 27.9 10.4 73 2 16.3 7.1 2.0 1 30.50 40 GEV072 230/60/3 27.0 10.4 73 2 16.3 6.2 2.0 1 29.60 40 GEV072 380-415/50/3 15.6 7.1/5.1 48/35 2 11/8 3.4 2.0 1 17.38 20 GEV072 460/60/3 14.7 5.8 38 2 9 3.1 2.0 1 16.16 20 GEV072 380-415/50/3 17.7 7.1/5.1 48/35 2 11/8 5.5 3.0 1 19.48 25 GEVE090 380-415/50/3 21.3 9.6 64 2 15 2.1 1.0 1 23.70 30 3.5 1.0 1 32.03 45 No. of Comp. GEV - Vertical Units GEV090 208/60/3 28.4 14.5/10.4 98/73 2 22.6/16.3 GEV090 230/60/3 28.7 14.5/10.4 98/73 2 22.6/16.3 3.8 1.0 1 32.33 45 GEV090 460/60/3 13.9 6.3/5.8 55/38 2 9.9/9 1.8 1.0 1 15.48 20 GEV090 208/60/3 30.5 14.5/10.4 98/73 2 22.6/16.3 5.6 1.5 1 34.13 45 GEV090 230/60/3 29.7 14.5/10.4 98/73 2 22.6/16.3 4.8 1.5 1 33.33 45 GEV090 380-415/50/3 22.2 9.6 64 2 15 3.0 1.5 1 24.60 30 GEV090 460/60/3 14.5 6.3/5.8 55/38 2 9.9/9 2.4 1.5 1 16.08 20 GEV090 208/60/3 32.0 14.5/10.4 98/73 2 22.6/16.3 7.1 2.0 1 35.63 50 GEV090 230/60/3 31.1 14.5/10.4 98/73 2 22.6/16.3 6.2 2.0 1 34.73 45 GEV090 380-415/50/3 22.6 9.6 64 2 15 3.4 2.0 1 25.00 30 GEV090 460/60/3 15.2 6.3/5.8 55/38 2 9.9/9 3.1 2.0 1 16.79 20 GEV090 575/60/3 12.1 6/3.8 41/36.5 2 9.4/5.9 2.3 2.0 1 13.60 15 GEV090 208/60/3 34.3 14.5/10.4 98/73 2 22.6/16.3 9.4 3.0 1 37.93 50 GEV090 230/60/3 33.1 14.5/10.4 98/73 2 22.6/16.3 8.2 3.0 1 36.73 50 GEV090 380-415/50/3 24.4 9.6 64 2 15 5.2 3.0 1 26.80 35 GEV090 460/60/3 16.2 6.3/5.8 55/38 2 9.9/9 4.1 3.0 1 17.78 20 GEV090 575/60/3 13.1 6/3.8 41/36.5 2 9.4/5.9 3.3 3.0 1 14.60 20 GEV120 208/60/3 37.6 16 110 2 24.9 5.6 1.5 1 41.60 50 GEV120 230/60/3 36.8 16 110 2 24.9 4.8 1.5 1 40.80 50 GEV120 460/60/3 18.0 7.8 52 2 12.1 2.4 1.5 1 19.95 25 GEV120 208/60/3 39.1 16 110 2 24.9 7.1 2.0 1 43.10 50 GEV120 230/60/3 38.2 16 110 2 24.9 6.2 2.0 1 42.20 50 GEV120 460/60/3 18.7 7.8 52 2 12.1 3.1 2.0 1 20.66 25 GEV120 575/60/3 13.7 5.7 38.9 2 8.9 2.3 2.0 1 15.13 20 GEV120 208/60/3 41.4 16 110 2 24.9 9.4 3.0 1 45.40 60 GEV120 230/60/3 40.2 16 110 2 24.9 8.2 3.0 1 44.20 60 GEV120 460/60/3 19.7 7.8 52 2 12.1 4.1 3.0 1 21.65 25 GEV120 575/60/3 14.7 5.7 38.9 2 8.9 3.3 3.0 1 16.13 20 GEV120 208/60/3 46.0 16 110 2 24.9 14.0 5.0 1 50.00 60 GEV120 230/60/3 45.0 16 110 2 24.9 13.0 5.0 1 49.00 60 GEV120 460/60/3 22.1 7.8 52 2 12.1 6.5 5.0 1 24.05 30 GEV120 575/60/3 16.7 5.7 38.9 2 8.9 5.3 5.0 1 18.13 20 GEV120 380-415/50/3 24.2 10.6 74 2 16.5 3.0 1.5 1 26.85 35 continued on next page WSHP-SVX01N-EN 85 Electrical Data Table 50. Electrical data: 6 to 25 tons - single speed blower motor (continued) Maximum Blower Blower Fan Minimum Overcurrent Motor Motor Motor Circuit Protective Cmp MCC FLA HP No. Ampacity Device Model No. Volts Total FLA Comp RLA (ea) Comp LRA (ea) GEV120 380-415/50/3 24.6 10.6 74 2 16.5 3.4 2.0 1 27.25 GEV120 380-415/50/3 26.4 10.6 74 2 16.5 5.2 3.0 1 29.05 35 GEV150 208/60/3 51.9 22.4 149 2 35 7.1 2.0 1 57.50 70 GEV150 230/60/3 51.0 22.4 149 2 35 6.2 2.0 1 56.60 70 GEV150 380-415/50/3 27.8 12.2 101 2 19 3.4 2.0 1 30.85 40 GEV150 460/60/3 24.3 10.6 75 2 16.5 3.1 2.0 1 26.96 35 GEV150 575/60/3 17.7 7.7 54 2 12 2.3 2.0 1 19.63 25 GEV150 208/60/3 54.2 22.4 149 2 35 9.4 3.0 1 59.80 80 GEV150 230/60/3 53.0 22.4 149 2 35 8.2 3.0 1 58.60 80 GEV150 380-415/50/3 29.6 12.2 101 2 19 5.2 3.0 1 32.65 40 GEV150 460/60/3 25.3 10.6 75 2 16.5 4.1 3.0 1 27.95 35 GEV150 575/60/3 18.7 7.7 54 2 12 3.3 3.0 1 20.63 25 GEV150 208/60/3 58.8 22.4 149 2 35 14.0 5.0 1 64.40 80 GEV150 230/60/3 57.8 22.4 149 2 35 13.0 5.0 1 63.40 80 GEV150 380-415/50/3 32.6 12.2 101 2 19 8.2 5.0 1 35.65 45 GEV150 460/60/3 27.7 10.6 75 2 16.5 6.5 5.0 1 30.35 40 GEV150 575/60/3 20.7 7.7 54 2 12 5.3 5.0 1 22.63 30 GEV180 208/60/3 59.4 25 164 2 39 9.4 3.0 1 65.65 90 GEV180 230/60/3 58.2 25 164 2 39 8.2 3.0 1 64.45 80 GEV180 380-415/50/3 38.6 16.7 111 2 26 5.2 3.0 1 42.78 50 GEV180 460/60/3 28.5 12.2 100 2 19 4.1 3.0 1 31.55 40 GEV180 575/60/3 21.3 9 78 2 14 3.3 3.0 1 23.55 30 GEV180 208/60/3 64.0 25 164 2 39 14.0 5.0 1 70.25 90 GEV180 230/60/3 63.0 25 164 2 39 13.0 5.0 1 69.25 90 GEV180 380-415/50/3 41.6 16.7 111 2 26 8.2 5.0 1 45.78 60 GEV180 460/60/3 30.9 12.2 100 2 19 6.5 5.0 1 33.95 45 GEV180 575/60/3 23.3 9 78 2 14 5.3 5.0 1 25.55 30 GEV180 208/60/3 70.0 25 164 2 39 20.0 7.5 1 76.25 100 GEV180 230/60/3 69.4 25 164 2 39 19.4 7.5 1 75.65 100 GEV180 380-415/50/3 44.9 16.7 111 2 26 11.5 7.5 1 49.08 60 GEV180 460/60/3 34.1 12.2 100 2 19 9.7 7.5 1 37.15 45 GEV180 575/60/3 26.0 9 78 2 14 8.0 7.5 1 28.25 35 GEV240 380-415/50/3 42.4 18.6 118 2 29 5.2 3.0 1 47.05 60 GEV240 208/60/3 74.2 30.1 225 2 47 14.0 5.0 1 81.73 110 GEV240 230/60/3 73.2 30.1 225 2 47 13.0 5.0 1 80.73 110 GEV240 380-415/50/3 45.4 18.6 118 2 29 8.2 5.0 1 50.05 60 GEV240 460/60/3 39.9 16.7 114 2 26 6.5 5.0 1 44.08 60 GEV240 575/60/3 29.7 12.2 80 2 19 5.3 5.0 1 32.75 40 GEV240 208/60/3 80.2 30.1 225 2 47 20.0 7.5 1 87.73 110 GEV240 230/60/3 79.6 30.1 225 2 47 19.4 7.5 1 87.13 110 GEV240 380-415/50/3 48.7 18.6 118 2 29 11.5 7.5 1 53.35 70 GEV240 460/60/3 43.1 16.7 114 2 26 9.7 7.5 1 47.28 60 GEV240 575/60/3 32.4 12.2 80 2 19 8.0 7.5 1 35.45 45 No. of Comp. GEV - Vertical Units 35 continued on next page 86 WSHP-SVX01N-EN Electrical Data Table 50. Electrical data: 6 to 25 tons - single speed blower motor (continued) Maximum Blower Blower Fan Minimum Overcurrent Motor Motor Motor Circuit Protective Cmp MCC FLA HP No. Ampacity Device Model No. Volts Total FLA Comp RLA (ea) Comp LRA (ea) GEV240 208/60/3 86.2 30.1 225 2 47 26.0 10.0 1 93.73 110 GEV240 230/60/3 85.2 30.1 225 2 47 25.0 10.0 1 92.73 110 GEV240 460/60/3 45.9 16.7 114 2 26 12.5 10.0 1 50.08 60 GEV240 575/60/3 34.4 12.2 80 2 19 10.0 10.0 1 37.45 45 GEV240 208/60/3 97.2 30.1 225 2 47 37.0 15.0 1 106.45 125 GEV240 230/60/3 96.2 30.1 225 2 47 36.0 15.0 1 105.20 125 GEV240 380-415/50/3 52.2 18.6 118 2 29 15.0 10.0 1 56.85 70 GEV240 460/60/3 51.4 16.7 114 2 26 18.0 15.0 1 55.90 70 GEV240 575/60/3 38.5 12.2 80 2 19 14.1 15.0 1 42.03 50 GEV300 208/60/3 110.2 48.1 245 2 75 14.0 5.0 1 122.23 150 GEV300 230/60/3 109.2 48.1 245 2 75 13.0 5.0 1 121.23 150 GEV300 460/60/3 43.7 18.6 125 2 29 6.5 5.0 1 48.35 60 GEV300 575/60/3 34.7 14.7 100 2 23 5.3 5.0 1 38.38 50 GEV300 208/60/3 116.2 48.1 245 2 75 20.0 7.5 1 128.23 175 GEV300 230/60/3 115.6 48.1 245 2 75 19.4 7.5 1 127.63 175 GEV300 460/60/3 46.9 18.6 125 2 29 9.7 7.5 1 51.55 70 GEV300 575/60/3 37.4 14.7 100 2 23 8.0 7.5 1 41.08 50 GEV300 208/60/3 122.2 48.1 245 2 75 26.0 10.0 1 134.23 175 GEV300 230/60/3 121.2 48.1 245 2 75 25.0 10.0 1 133.23 175 GEV300 460/60/3 49.7 18.6 125 2 29 12.5 10.0 1 54.35 70 GEV300 575/60/3 39.4 14.7 100 2 23 10.0 10.0 1 43.08 50 GEV300 208/60/3 133.2 48.1 245 2 75 37.0 15.0 1 145.23 175 GEV300 230/60/3 132.2 48.1 245 2 75 36.0 15.0 1 144.23 175 GEV300 460/60/3 55.2 18.6 125 2 29 18.0 15.0 1 59.85 70 GEV300 575/60/3 43.5 14.7 100 2 23 14.1 15.0 1 47.18 60 No. of Comp. GEV - Vertical Units Table 51. Electrical data: 6 to 25 tons - two speed blower motor Maximum Blower Blower Fan Minimum Overcurrent Motor Motor Motor Circuit Protective Cmp MCC FLA HP No. Ampacity Device Model No. Volts Total FLA Comp RLA (ea) Comp LRA (ea) GEH072 208/60/3 24.1 10.4 73 2 16.3 3.3 1.0 1 26.70 35 GEH072 230/60/3 23.8 10.4 73 2 16.3 3.0 1.0 1 26.40 35 GEH072 460/60/3 13.1 5.8 38 2 9 1.5 1.0 1 14.55 20 GEH072 208/60/3 25.7 10.4 73 2 16.3 4.9 1.5 1 28.30 35 GEH072 230/60/3 25.2 10.4 73 2 16.3 4.4 1.5 1 27.80 35 GEH072 460/60/3 13.8 5.8 38 2 9 2.2 1.5 1 15.25 20 GEH072 208/60/3 27.5 10.4 73 2 16.3 6.7 2.0 1 30.10 40 GEH072 230/60/3 26.9 10.4 73 2 16.3 6.1 2.0 1 29.50 35 GEH072 460/60/3 14.7 5.8 38 2 9 3.1 2.0 1 16.15 20 GEH090 208/60/3 28.2 14.5/10.4 98/73 2 22.6/16.3 3.3 1.0 1 31.83 45 GEH090 230/60/3 27.9 14.5/10.4 98/73 2 22.6/16.3 3.0 1.0 1 31.53 45 No. of Comp. GEH - Horizontal Units continued on next page WSHP-SVX01N-EN 87 Electrical Data Table 51. Electrical data: 6 to 25 tons - two speed blower motor (continued) Maximum Blower Blower Fan Minimum Overcurrent Motor Motor Motor Circuit Protective Cmp MCC FLA HP No. Ampacity Device Model No. Volts Total FLA Comp RLA (ea) Comp LRA (ea) GEH090 460/60/3 13.6 6.3/5.8 55/38 2 9.9/9 1.5 1.0 1 15.18 20 GEH090 208/60/3 29.8 14.5/10.4 98/73 2 22.6/16.3 4.9 1.5 1 33.43 45 GEH090 230/60/3 29.3 14.5/10.4 98/73 2 22.6/16.3 4.4 1.5 1 32.93 45 GEH090 460/60/3 14.3 6.3/5.8 55/38 2 9.9/9 2.2 1.5 1 15.88 20 GEH090 208/60/3 31.6 14.5/10.4 98/73 2 22.6/16.3 6.7 2.0 1 35.23 45 GEH090 230/60/3 31.0 14.5/10.4 98/73 2 22.6/16.3 6.1 2.0 1 34.63 45 GEH090 460/60/3 15.2 6.3/5.8 55/38 2 9.9/9 3.1 2.0 1 16.78 20 GEH090 208/60/3 33.7 14.5/10.4 98/73 2 22.6/16.3 8.8 3.0 1 37.33 50 GEH090 230/60/3 32.9 14.5/10.4 98/73 2 22.6/16.3 8.0 3.0 1 36.53 50 GEH090 460/60/3 16.6 6.3 55 2 9.9 4.0 3.0 1 18.18 20 GEH120 208/60/3 36.9 16 110 2 24.9 4.9 1.5 1 40.90 50 GEH120 230/60/3 36.4 16 110 2 24.9 4.4 1.5 1 40.40 50 GEH120 460/60/3 17.8 7.8 52 2 12.1 2.2 1.5 1 19.75 25 GEH120 208/60/3 38.7 16 110 2 24.9 6.7 2.0 1 42.70 50 GEH120 230/60/3 38.1 16 110 2 24.9 6.1 2.0 1 42.10 50 GEH120 460/60/3 18.7 7.8 52 2 12.1 3.1 2.0 1 20.65 25 GEH120 208/60/3 40.8 16 110 2 24.9 8.8 3.0 1 44.80 60 GEH120 230/60/3 40.0 16 110 2 24.9 8.0 3.0 1 44.00 60 GEH120 460/60/3 19.6 7.8 52 2 12.1 4.0 3.0 1 21.55 25 GEH120 208/60/3 46.6 16 110 2 24.9 14.6 5.0 1 50.60 60 GEH120 230/60/3 45.2 16 110 2 24.9 13.2 5.0 1 49.20 60 GEH120 460/60/3 22.2 7.8 52 2 12.1 6.6 5.0 1 24.15 30 GEH150 208/60/3 49.7 22.4 149 2 35 4.9 1.5 1 55.30 70 GEH150 230/60/3 49.2 22.4 149 2 35 4.4 1.5 1 54.80 70 GEH150 460/60/3 23.4 10.6 75 2 16.5 2.2 1.5 1 26.05 35 GEH150 208/60/3 51.5 22.4 149 2 35 6.7 2.0 1 57.10 70 GEH150 230/60/3 50.9 22.4 149 2 35 6.1 2.0 1 56.50 70 GEH150 460/60/3 24.3 10.6 75 2 16.5 3.1 2.0 1 26.95 35 GEH150 208/60/3 53.6 22.4 149 2 35 8.8 3.0 1 59.20 80 GEH150 230/60/3 52.8 22.4 149 2 35 8.0 3.0 1 58.40 80 GEH150 460/60/3 25.2 10.6 75 2 16.5 4.0 3.0 1 27.85 35 GEH150 208/60/3 59.4 22.4 149 2 35 14.6 5.0 1 65.00 80 GEH150 230/60/3 58.0 22.4 149 2 35 13.2 5.0 1 63.60 80 GEH150 460/60/3 27.8 10.6 75 2 16.5 6.6 5.0 1 30.45 40 GEH180 208/60/3 56.7 25 164 2 39 6.7 2.0 1 62.95 80 GEH180 230/60/3 56.1 25 164 2 39 6.1 2.0 1 62.35 80 GEH180 460/60/3 27.5 12.2 100 2 19 3.1 2.0 1 30.55 40 GEH180 208/60/3 58.8 25 164 2 39 8.8 3.0 1 65.05 90 GEH180 230/60/3 58.0 25 164 2 39 8.0 3.0 1 64.25 80 GEH180 460/60/3 28.4 12.2 100 2 19 4.0 3.0 1 31.45 40 GEH180 208/60/3 64.6 25 164 2 39 14.6 5.0 1 70.85 90 GEH180 230/60/3 63.2 25 164 2 39 13.2 5.0 1 69.45 90 GEH180 460/60/3 31.0 12.2 100 2 19 6.6 5.0 1 34.05 45 No. of Comp. GEH - Horizontal Units continued on next page 88 WSHP-SVX01N-EN Electrical Data Table 51. Electrical data: 6 to 25 tons - two speed blower motor (continued) Maximum Blower Blower Fan Minimum Overcurrent Motor Motor Motor Circuit Protective Cmp MCC FLA HP No. Ampacity Device Model No. Volts Total FLA Comp RLA (ea) Comp LRA (ea) GEH180 208/60/3 72.1 25 164 2 39 22.1 7.5 1 78.35 100 GEH180 230/60/3 70.0 25 164 2 39 20.0 7.5 1 76.25 100 GEH180 460/60/3 34.4 12.2 100 2 19 10.0 7.5 1 37.45 45 GEV072 208/60/3 24.1 10.4 73 2 16.3 3.3 1.0 1 26.70 35 GEV072 230/60/3 23.8 10.4 73 2 16.3 3.0 1.0 1 26.40 35 GEV072 460/60/3 13.1 5.8 38 2 9 1.5 1.0 1 14.55 20 GEV072 208/60/3 25.7 10.4 73 2 16.3 4.9 1.5 1 28.30 35 GEV072 230/60/3 25.2 10.4 73 2 16.3 4.4 1.5 1 27.80 35 GEV072 460/60/3 13.8 5.8 38 2 9 2.2 1.5 1 15.25 20 GEV072 208/60/3 27.5 10.4 73 2 16.3 6.7 2.0 1 30.10 40 GEV072 230/60/3 26.9 10.4 73 2 16.3 6.1 2.0 1 29.50 35 GEV072 460/60/3 14.7 5.8 38 2 9 3.1 2.0 1 16.15 20 GEV090 208/60/3 28.2 14.5/10.4 98/73 2 22.6/16.3 3.3 1.0 1 31.83 45 GEV090 230/60/3 27.9 14.5/10.4 98/73 2 22.6/16.3 3.0 1.0 1 31.53 45 GEV090 460/60/3 13.6 6.3/5.8 55/38 2 9.9/9 1.5 1.0 1 15.18 20 GEV090 208/60/3 29.8 14.5/10.4 98/73 2 22.6/16.3 4.9 1.5 1 33.43 45 GEV090 230/60/3 29.3 14.5/10.4 98/73 2 22.6/16.3 4.4 1.5 1 32.93 45 GEV090 460/60/3 14.3 6.3/5.8 55/38 2 9.9/9 2.2 1.5 1 15.88 20 GEV090 208/60/3 31.6 14.5/10.4 98/73 2 22.6/16.3 6.7 2.0 1 35.23 45 GEV090 230/60/3 31.0 14.5/10.4 98/73 2 22.6/16.3 6.1 2.0 1 34.63 45 GEV090 460/60/3 15.2 6.3/5.8 55/38 2 9.9/9 3.1 2.0 1 16.78 20 GEV090 208/60/3 33.7 14.5/10.4 98/73 2 22.6/16.3 8.8 3.0 1 37.33 50 GEV090 230/60/3 32.9 14.5/10.4 98/73 2 22.6/16.3 8.0 3.0 1 36.53 50 GEV090 460/60/3 16.1 6.3/5.8 55/38 2 9.9/9 4.0 3.0 1 17.68 20 GEV120 208/60/3 36.9 16 110 2 24.9 4.9 1.5 1 40.90 50 GEV120 230/60/3 36.4 16 110 2 24.9 4.4 1.5 1 40.40 50 GEV120 460/60/3 17.8 7.8 52 2 12.1 2.2 1.5 1 19.75 25 GEV120 208/60/3 38.7 16 110 2 24.9 6.7 2.0 1 42.70 50 GEV120 230/60/3 38.1 16 110 2 24.9 6.1 2.0 1 42.10 50 GEV120 460/60/3 18.7 7.8 52 2 12.1 3.1 2.0 1 20.65 25 GEV120 208/60/3 40.8 16 110 2 24.9 8.8 3.0 1 44.80 60 GEV120 230/60/3 40.0 16 110 2 24.9 8.0 3.0 1 44.00 60 GEV120 460/60/3 19.6 7.8 52 2 12.1 4.0 3.0 1 21.55 25 GEV120 208/60/3 46.6 16 110 2 24.9 14.6 5.0 1 50.60 60 GEV120 230/60/3 45.2 16 110 2 24.9 13.2 5.0 1 49.20 60 GEV120 460/60/3 22.2 7.8 52 2 12.1 6.6 5.0 1 24.15 30 GEV150 208/60/3 51.5 22.4 149 2 35 6.7 2.0 1 57.10 70 GEV150 230/60/3 50.9 22.4 149 2 35 6.1 2.0 1 56.50 70 GEV150 460/60/3 24.3 10.6 75 2 16.5 3.1 2.0 1 26.95 35 GEV150 208/60/3 53.6 22.4 149 2 35 8.8 3.0 1 59.20 80 GEV150 230/60/3 52.8 22.4 149 2 35 8.0 3.0 1 58.40 80 GEV150 460/60/3 25.2 10.6 75 2 16.5 4.0 3.0 1 27.85 35 No. of Comp. GEH - Horizontal Units GEV - Vertical Units continued on next page WSHP-SVX01N-EN 89 Electrical Data Table 51. Electrical data: 6 to 25 tons - two speed blower motor (continued) Maximum Blower Blower Fan Minimum Overcurrent Motor Motor Motor Circuit Protective Cmp MCC FLA HP No. Ampacity Device Model No. Volts Total FLA Comp RLA (ea) Comp LRA (ea) GEV150 208/60/3 59.4 22.4 149 2 35 14.6 5.0 1 65.00 80 GEV150 230/60/3 58.0 22.4 149 2 35 13.2 5.0 1 63.60 80 GEV150 460/60/3 27.8 10.6 75 2 16.5 6.6 5.0 1 30.45 40 GEV180 208/60/3 58.8 25 164 2 39 8.8 3.0 1 65.05 90 GEV180 230/60/3 58.0 25 164 2 39 8.0 3.0 1 64.25 80 GEV180 460/60/3 28.4 12.2 100 2 19 4.0 3.0 1 31.45 40 GEV180 208/60/3 64.6 25 164 2 39 14.6 5.0 1 70.85 90 GEV180 230/60/3 63.2 25 164 2 39 13.2 5.0 1 69.45 90 GEV180 460/60/3 31.0 12.2 100 2 19 6.6 5.0 1 34.05 45 GEV180 208/60/3 72.1 25 164 2 39 22.1 7.5 1 78.35 100 GEV180 230/60/3 70.0 25 164 2 39 20.0 7.5 1 76.25 100 GEV180 460/60/3 34.4 12.2 100 2 19 10.0 7.5 1 37.45 45 GEV240 208/60/3 74.8 30.1 225 2 47 14.6 5.0 1 82.33 110 GEV240 230/60/3 73.4 30.1 225 2 47 13.2 5.0 1 80.93 110 GEV240 460/60/3 40.0 16.7 114 2 26 6.6 5.0 1 44.18 60 GEV240 208/60/3 82.3 30.1 225 2 47 22.1 7.5 1 89.83 110 GEV240 230/60/3 80.2 30.1 225 2 47 20.0 7.5 1 87.73 110 GEV240 460/60/3 43.4 16.7 114 2 26 10.0 7.5 1 47.58 60 GEV240 208/60/3 87.8 30.1 225 2 47 27.6 10.0 1 95.33 125 GEV240 230/60/3 85.2 30.1 225 2 47 25.0 10.0 1 92.73 110 GEV240 460/60/3 46.4 16.7 114 2 26 13.0 10.0 1 50.58 60 GEV240 460/60/3 53.4 16.7 114 2 26 20.0 15.0 1 58.40 70 GEV300 208/60/3 110.8 48.1 245 2 75 14.6 5.0 1 122.83 150 GEV300 230/60/3 109.4 48.1 245 2 75 13.2 5.0 1 121.43 150 GEV300 460/60/3 43.8 18.6 125 2 29 6.6 5.0 1 48.45 60 GEV300 208/60/3 118.3 48.1 245 2 75 22.1 7.5 1 130.33 175 GEV300 230/60/3 116.2 48.1 245 2 75 20.0 7.5 1 128.23 175 GEV300 460/60/3 47.2 18.6 125 2 29 10.0 7.5 1 51.85 70 GEV300 208/60/3 123.8 48.1 245 2 75 27.6 10.0 1 135.83 175 GEV300 230/60/3 121.2 48.1 245 2 75 25.0 10.0 1 133.23 175 GEV300 460/60/3 50.2 18.6 125 2 29 13.0 10.0 1 54.85 70 GEV300 460/60/3 57.2 18.6 125 2 29 20.0 15.0 1 62.20 80 No. of Comp. GEV - Vertical Units 90 WSHP-SVX01N-EN Electrical Data Table 52. Electrical minimum and maximum Digit 8 Rated Voltage Hz Ph Min Utiliz. Volts 0 115 60 1 104 Max Utiliz. Volts 126 1 208 60 1 197 229 2 230 60 1 207 253 3 208 60 3 187 229 4 460 60 3 414 506 5 575 60 3 518 633 6 220-240 50 1 198 264 7 265 60 1 239 292 8 230 60 3 207 253 9 380-415 50 3 342 456 WSHP-SVX01N-EN 91 Pre-Start Checklist Before energizing the unit, the following system devices must be checked: • Are the low/high-side pressure temperature caps secure and in place? • Is the high voltage power supply correct and in accordance with the nameplate ratings? • Are all the unit access panels secure and in place? • Is the thermostat in the OFF position? • Is phasing of the unit correct per compressor rotation (scroll compressor only)? • Is the water flow established and circulating through all the units? • Is the field wiring and circuit protection the correct size? • Is the duct work correctly sized, run, taped, insulated and weather proofed with proper unit arrangement? • Is the low voltage control circuit wiring correct per the unit wiring diagram? • Is the condensate line properly sized, run, trapped, pitched and primed? • Is the piping system clean/complete and correct? (A recommendation of all system flushing of debris from the water-to-refrigerant heat exchanger, along with air purging from the water-to-refrigerant heat exchanger be done in accordance with the Closed-Loop/Ground Source Heat Pump Systems Installation Guide). • Is the zone sensor correctly wired and in a good location? • Does the indoor blower turn freely without rubbing? • Has all work been done in accordance with applicable local and national codes? • Is vibration isolation provided? (i.e. unit isolation pad, hose kits) Has heat transfer fluid been added in the proper mix to prevent freezing in closed system application? • Is unit serviceable? (See clearance specifications in “Unit Dimensions and Weights,” p. 14). 92 WSHP-SVX01N-EN Start-Up Initial Unit Start-up Table 53. Note: Start-up with the heat pump thermostat is included below: 1. Set the thermostat to the highest position. Checklist MODE Pressure Differential Heat Cool _________PSI _________PSI G G COMPRESSOR 2. Set the thermostat system switch to COOL with the fan control to AUTO.The compressor should NOT run. Amps 3. Reduce the thermostat setting until the compressor, reversing valve, solenoid valve, and loop pump are energized. Adjust water flow utilizing pressure/ temperature plugs and comparing to tables contained in specification sheet data. Discharge line temperature (after 10 minutes) Water leaving the heat exchanger should be warmer than the entering water temperature (approximately 912ºF); blower operation should be smooth; compressor and blower amps should be within data plate ratings; the suction line should be cool with no frost observed in the refrigerant circuit. Volts _______F _______F Start-Up Checklist and Log Installing Contractor: Use this checklist to thoroughly check-out the system and units before and during start-up. (This form need not be returned to the factory unless requested during technical service support). Job Name:________________________ Model Number:____________________ 4. Check the cooling refrigerant pressures against values in Table 54, p. 94. Date:______________________________ 5. Turn the thermostat system switch to the OFF position. Unit should stop running and the reversing valve should de-energize. In order to minimize troubleshooting and costly system failures, complete the following checks and data entries before the system is put into full operation. 6. Leave unit off for approximately FIVE minutes to allow for pressure equalization. Operating Pressures 7. Turn the thermostat to the lowest setting. There are many variables (airflow, air temperatures) in an air conditioning system that will affect operating refrigerant pressures and temperatures.The charts below shows approximate conditions and is based on air flow at the rated SCFM, entering air at 80.6°F(DB), 66.2°F(WB) in cooling, 68°F(DB) in heating. (+)Heating data with 35°F EWT is based on the use of an anti-freeze solution having a freezing point 20°F lower than the minimum expected entering temperature. 8. Set the thermostat system switch to the HEAT position. 9. Adjust the temperature setting upward until the unit is energized. Warm air should blow from the register. A water temperature decrease of approximately 5-9ºF leaving the heat exchanger should be noted.The blower and compressor operation should be smooth with no frost observed in the refrigeration circuit. Serial Number:_____________________ 10. Check the heating refrigerant pressures against values in Table 54, p. 94. 11. Set the thermostat to maintain the desired space temperature. 12. Instruct the owner on system operation. Table 53. Checklist MODE Heat Cool Entering fluid temperature _______F _______F Leaving fluid temperature _______F _______F Temperature differential _______F _______F Return-air temperature DB/WB _______F _______F Supply-air temperature DB/WB _______F _______F Temperature differential _______F _______F Water coil heat exchanger (Water Pressure IN) ________PSIG ________PSIG Water coil heat exchanger (Water Pressure OUT) ________PSIG ________PSIG WSHP-SVX01N-EN 93 Start-Up Table 54. Operating pressures in cooling/heating for GE* units Operating Data Cooling Heating Suction Discharge Water Air Temp Pressure Pressure Temp Rise Drop (psig) (psig) (°F) (°F DB) Suction Discharge Water Air Temp Pressure Pressure Temp Rise (psig) (psig) Drop (°F) (°F DB) Model No. Entering Water Temp (°F) Water Flow (GPM) 006 (60 Hz) 35 1.4 — — — — 94-108 279-355 6-8 23-29 006 (60 Hz) 35 1.7 — — — — 96-110 281-357 5-6 23-29 006 (60 Hz) 45 1.4 143-165 190-243 13-16 24-30 110-127 297-377 7-9 26-34 006 (60 Hz) 45 1.7 143-164 184-235 11-13 24-31 113-130 300-382 6-8 27-34 006 (60 Hz) 55 1.4 145-167 217-277 13-16 23-30 128-147 317-404 8-10 30-39 006 (60 Hz) 55 1.7 144-166 210-268 11-13 24-30 131-151 320-407 7-9 31-39 006 (60 Hz) 68 1.4 148-171 254-324 12-15 23-29 154-177 345-439 10-12 35-45 006 (60 Hz) 68 1.7 147-170 244-312 10-13 23-29 158-182 349-444 8-10 36-45 006 (60 Hz) 75 1.4 148-171 281-358 12-15 23-29 169-195 361-459 10-13 38-48 006 (60 Hz) 75 1.7 148-170 273-348 10-13 23-29 175-201 366-466 9-11 38-48 006 (60 Hz) 86 1.4 149-172 328-418 12-15 22-28 197-226 388-494 11-15 41-52 006 (60 Hz) 86 1.7 149-172 320-407 10-13 23-29 203-234 395-502 10-12 41-52 006 (60 Hz) 95 1.4 151-173 373-474 12-15 22-28 — — — — 006 (60 Hz) 95 1.7 150-173 363-462 10-13 22-28 — — — — 009 (60Hz) 006 (50 Hz) 35 1.7 — — — — 93-107 272-346 6-7 20-26 009 (60Hz) 006 (50 Hz) 35 2.1 — — — — 95-110 274-348 5-6 21-27 009 (60Hz) 006 (50 Hz) 45 1.7 142-164 187-238 13-16 22-28 109-126 288-366 7-9 24-30 009 (60Hz) 006 (50 Hz) 45 2.1 142-164 181-230 11-14 22-27 112-129 291-370 6-7 24-31 009 (60Hz) 006 (50 Hz) 55 1.7 144-166 214-272 12-15 21-27 127-146 305-388 8-10 27-34 009 (60Hz) 006 (50 Hz) 55 2.1 144-166 207-263 10-13 21-27 130-150 309-393 7-8 27-35 009 (60Hz) 006 (50 Hz) 68 1.7 146-168 258-328 12-15 20-26 153-176 330-420 9-12 31-39 009 (60Hz) 006 (50 Hz) 68 2.1 146-168 250-318 10-12 21-26 157-181 335-427 8-10 32-40 009 (60Hz) 006 (50 Hz) 75 1.7 147-169 286-363 12-15 20-25 168-193 345-439 10-13 33-42 009 (60Hz) 006 (50 Hz) 75 2.1 147-169 277-352 9-12 20-26 174-200 350-446 8-11 34-43 009 (60Hz) 006 (50 Hz) 86 1.7 149-171 336-427 12-15 19-25 195-224 370-471 11-14 36-46 009 (60Hz) 006 (50 Hz) 86 2.1 148-171 326-415 9-12 20-25 202-232 375-477 9-12 37-47 009 (60Hz) 006 (50 Hz) 95 1.7 149-172 386-491 12-15 19-24 — — — — 009 (60Hz) 006 (50 Hz) 95 2.1 149-172 375-477 9-12 19-24 — — — — 012 (60Hz) 009 (50 Hz) 35 2.2 — — — — 92-106 288-367 10-13 21-27 012 (60Hz) 009 (50 Hz) 35 2.8 — — — — 95-109 290-370 8-11 21-27 GEH*/GEV* 94 WSHP-SVX01N-EN Start-Up Table 54. Operating pressures in cooling/heating for GE* units (continued) Operating Data Model No. Entering Water Temp (°F) Water Flow (GPM) Cooling Heating Suction Discharge Water Air Temp Pressure Pressure Temp Rise Drop (psig) (psig) (°F) (°F DB) Suction Discharge Water Air Temp Pressure Pressure Temp Rise (psig) (psig) Drop (°F) (°F DB) GEH*/GEV* 012 (60Hz) 009 (50 Hz) 45 2.2 142-163 183-233 12-15 22-28 108-125 304-387 12-15 24-30 012 (60Hz) 009 (50 Hz) 45 2.8 142-163 175-223 9-12 23-29 111-128 307-391 9-12 24-31 012 (60Hz) 009 (50 Hz) 55 2.2 143-164 212-270 12-15 21-27 126-145 322-410 13-16 26-33 012 (60Hz) 009 (50 Hz) 55 2.8 143-164 204-260 9-12 22-27 130-149 325-413 10-13 27-34 012 (60Hz) 009 (50 Hz) 68 2.2 144-166 257-327 12-15 21-26 152-174 346-441 14-18 29-37 012 (60Hz) 009 (50 Hz) 68 2.8 144-166 248-316 9-12 21-26 157-180 352-448 11-15 29-37 012 (60Hz) 009 (50 Hz) 75 2.2 145-167 284-361 12-15 20-26 167-192 361-460 15-19 30-38 012 (60Hz) 009 (50 Hz) 75 2.8 145-167 274-349 9-12 20-26 173-199 366-466 12-15 30-39 012 (60Hz) 009 (50 Hz) 86 2.2 146-168 332-422 12-15 19-25 194-223 384-489 16-21 32-40 012 (60Hz) 009 (50 Hz) 86 2.8 146-168 321-409 9-12 20-25 201-231 390-497 13-17 32-41 012 (60Hz) 009 (50 Hz) 95 2.2 147-170 376-478 12-15 19-24 — — — — 012 (60Hz) 009 (50 Hz) 95 2.8 147-170 365-465 9-12 19-24 — — — — 015 (60Hz) 012 (50 Hz) 35 2.8 — — — — 91-105 296-377 6-7 20-25 015 (60Hz) 012 (50 Hz) 35 3.5 — — — — 93-107 299-380 5-6 20-26 015 (60Hz) 012 (50 Hz) 45 2.8 138-159 180-230 11-14 22-28 107-123 313-398 7-8 23-29 015 (60Hz) 012 (50 Hz) 45 3.5 138-158 174-221 9-11 22-27 109-126 316-402 5-7 23-30 015 (60Hz) 012 (50 Hz) 55 2.8 139-159 210-267 11-14 21-27 124-143 332-423 8-10 26-33 015 (60Hz) 012 (50 Hz) 55 3.5 138-159 203-258 9-11 21-27 128-147 336-427 6-8 27-34 015 (60Hz) 012 (50 Hz) 68 2.8 140-161 254-324 11-14 20-26 150-172 358-456 9-11 30-38 015 (60Hz) 012 (50 Hz) 68 3.5 140-161 246-313 9-11 21-26 154-178 364-463 7-9 30-39 015 (60Hz) 012 (50 Hz) 75 2.8 141-162 281-358 11-14 20-25 165-190 373-475 10-12 32-40 015 (60Hz) 012 (50 Hz) 75 3.5 140-162 272-347 9-11 20-26 171-196 379-483 8-10 32-41 015 (60Hz) 012 (50 Hz) 86 2.8 142-163 328-417 11-14 19-25 191-220 399-508 11-14 34-43 015 (60Hz) 012 (50 Hz) 86 3.5 142-163 318-405 9-11 20-25 198-228 405-515 9-11 34-44 WSHP-SVX01N-EN 95 Start-Up Table 54. Operating pressures in cooling/heating for GE* units (continued) Operating Data Model No. Entering Water Temp (°F) Water Flow (GPM) Cooling Heating Suction Discharge Water Air Temp Pressure Pressure Temp Rise Drop (psig) (psig) (°F) (°F DB) Suction Discharge Water Air Temp Pressure Pressure Temp Rise (psig) (psig) Drop (°F) (°F DB) GEH*/GEV* 015 (60Hz) 012 (50 Hz) 95 2.8 143-165 371-472 11-14 19-24 — — — — 015 (60Hz) 012 (50 Hz) 95 3.5 143-165 361-459 9-11 19-24 — — — — 018 (60Hz) 015 (50 Hz) 35 3.3 — — — — 89-102 276-351 6-7 21-26 018 (60Hz) 015 (50 Hz) 35 4.2 — — — — 91-105 279-354 5-6 21-27 018 (60Hz) 015 (50 Hz) 45 3.3 142-163 186-237 12-15 23-29 104-120 292-372 7-9 24-30 018 (60Hz) 015 (50 Hz) 45 4.2 142-163 179-227 9-12 23-29 107-123 295-376 5-7 24-31 018 (60Hz) 015 (50 Hz) 55 3.3 142-163 216-275 12-15 23-29 121-139 310-395 8-10 27-34 018 (60Hz) 015 (50 Hz) 55 4.2 142-163 207-264 9-12 23-29 125-143 313-399 6-8 27-35 018 (60Hz) 015 (50 Hz) 68 3.3 142-163 262-333 12-15 22-28 146-168 334-425 9-12 31-39 018 (60Hz) 015 (50 Hz) 68 4.2 142-163 252-321 9-12 22-28 151-174 338-430 7-9 32-40 018 (60Hz) 015 (50 Hz) 75 3.3 142-164 289-368 12-15 21-27 161-185 347-441 10-13 33-42 018 (60Hz) 015 (50 Hz) 75 4.2 142-164 280-356 9-12 21-27 167-192 351-447 8-10 34-43 018 (60Hz) 015 (50 Hz) 86 3.3 143-165 338-430 12-15 20-26 188-216 365-464 11-14 36-46 018 (60Hz) 015 (50 Hz) 86 4.2 143-165 327-416 9-12 20-26 195-225 370-471 9-11 37-47 018 (60Hz) 015 (50 Hz) 95 3.3 144-166 383-488 12-15 19-24 — — — — 018 (60Hz) 015 (50 Hz) 95 4.2 144-166 372-473 9-12 19-25 — — — — GEH*024 96 024 (60Hz) 018 (50Hz) 35 — — — — — 76-88 279-355 6-7 21-30 024 (60Hz) 018 (50Hz) 35 — — — — — 78-89 280-357 5-6 21-31 024 (60Hz) 018 (50Hz) 45 4.5 114-131 172-219 12-16 20-26 89-103 290-369 7-9 24-34 024 (60Hz) 018 (50Hz) 45 5.6 114-131 165-211 10-13 20-26 91-105 292-371 6-7 24-34 024 (60Hz) 018 (50Hz) 55 4.5 115-132 200-255 12-15 20-26 106-122 307-390 8-10 27-37 024 (60Hz) 018 (50Hz) 55 5.6 115-132 193-246 10-12 20-26 108-125 309-394 6-8 28-38 024 (60Hz) 018 (50Hz) 68 4.5 120-139 239-304 12-15 19-25 124-143 326-415 9-12 31-42 024 (60Hz) 018 (50Hz) 68 5.6 120-138 231-294 10-12 20-25 129-148 330-420 7-9 32-43 WSHP-SVX01N-EN Start-Up Table 54. Operating pressures in cooling/heating for GE* units (continued) Operating Data Model No. Entering Water Temp (°F) Water Flow (GPM) Cooling Heating Suction Discharge Water Air Temp Pressure Pressure Temp Rise Drop (psig) (psig) (°F) (°F DB) Suction Discharge Water Air Temp Pressure Pressure Temp Rise (psig) (psig) Drop (°F) (°F DB) GEH*024 024 (60Hz) 018 (50Hz) 75 4.5 121-140 264-336 12-15 19-25 139-159 340-432 10-13 34-44 024 (60Hz) 018 (50Hz) 75 5.6 121-139 256-325 9-12 19-25 143-165 343-437 8-10 34-45 024 (60Hz) 018 (50Hz) 86 4.5 124-143 305-389 12-15 18-24 163-188 363-462 11-14 38-49 024 (60Hz) 018 (50Hz) 86 5.6 124-143 297-378 9-12 19-24 169-195 368-468 9-12 39-50 024 (60Hz) 018 (50Hz) 95 4.5 126-145 344-437 12-15 18-24 — — — — 024 (60Hz) 018 (50Hz) 95 5.6 126-145 335-426 9-12 18-24 — — — — GEV*024 024 (60Hz) 018 (50Hz) 35 — — — — — 76-87 270-344 6-7 21-30 024 (60Hz) 018 (50Hz) 35 — — — — — 78-89 272-346 5-6 21-31 024 (60Hz) 018 (50Hz) 45 4.5 114-132 173-221 12-16 20-26 88-102 283-360 7-9 24-34 024 (60Hz) 018 (50Hz) 45 5.6 114-131 167-212 10-12 20-26 90-104 285-362 6-7 24-34 024 (60Hz) 018 (50Hz) 55 4.5 116-133 202-258 12-15 20-25 105-121 299-381 8-10 27-37 024 (60Hz) 018 (50Hz) 55 5.6 116-133 195-249 10-12 20-26 107-124 301-384 6-8 28-38 024 (60Hz) 018 (50Hz) 68 4.5 122-140 242-308 12-15 20-26 123-141 315-401 9-12 31-41 024 (60Hz) 018 (50Hz) 68 5.6 122-140 234-298 10-12 20-26 127-146 318-405 7-9 32-42 024 (60Hz) 018 (50Hz) 75 4.5 123-141 268-341 12-15 19-25 137-158 327-417 10-13 34-44 024 (60Hz) 018 (50Hz) 75 5.6 123-141 259-330 10-12 20-25 142-163 331-421 8-10 34-45 024 (60Hz) 018 (50Hz) 86 4.5 126-145 310-394 12-15 19-25 161-186 349-444 11-14 38-49 024 (60Hz) 018 (50Hz) 86 5.6 125-144 301-383 9-12 19-25 167-193 353-449 9-12 39-50 024 (60Hz) 018 (50Hz) 95 4.5 127-146 349-445 12-15 19-25 — — — — 024 (60Hz) 018 (50Hz) 95 5.6 127-146 340-433 9-12 19-25 — — — — GEH*030 030 (60 Hz) 024 (50 Hz) 35 — — — — — 77-89 276-351 6-7 21-30 030 (60 Hz) 024 (50 Hz) 35 — — — — — 79-90 277-352 4-6 21-30 030 (60 Hz) 024 (50 Hz) 45 5.6 120-138 171-218 12-15 22-27 91-104 290-369 7-8 24-34 030 (60 Hz) 024 (50 Hz) 45 7.0 120-138 165-210 10-12 22-28 93-107 292-371 5-7 24-34 WSHP-SVX01N-EN 97 Start-Up Table 54. Operating pressures in cooling/heating for GE* units (continued) Operating Data Model No. Entering Water Temp (°F) Water Flow (GPM) Cooling Heating Suction Discharge Water Air Temp Pressure Pressure Temp Rise Drop (psig) (psig) (°F) (°F DB) Suction Discharge Water Air Temp Pressure Pressure Temp Rise (psig) (psig) Drop (°F) (°F DB) GEH*030 030 (60 Hz) 024 (50 Hz) 55 5.6 121-140 200-254 12-15 21-27 108-124 307-390 8-10 27-37 030 (60 Hz) 024 (50 Hz) 55 7.0 121-139 193-245 9-12 22-27 111-127 309-393 6-8 28-38 030 (60 Hz) 024 (50 Hz) 68 5.6 122-140 249-317 12-15 20-26 128-148 329-419 9-11 32-42 030 (60 Hz) 024 (50 Hz) 68 7.0 122-140 241-306 9-12 20-26 133-152 333-423 7-9 32-43 030 (60 Hz) 024 (50 Hz) 75 5.6 123-141 275-350 12-15 20-26 143-164 342-436 10-12 34-45 030 (60 Hz) 024 (50 Hz) 75 7.0 123-141 267-340 9-12 20-26 148-170 346-440 8-10 35-46 030 (60 Hz) 024 (50 Hz) 86 5.6 126-146 310-395 11-14 20-26 168-193 365-465 11-14 38-49 030 (60 Hz) 024 (50 Hz) 86 7.0 126-145 302-384 9-11 20-26 174-200 370-470 9-11 39-50 030 (60 Hz) 024 (50 Hz) 95 5.6 128-148 350-446 11-14 19-25 — — — — 030 (60 Hz) 024 (50 Hz) 95 7.0 128-147 341-434 9-11 19-25 — — — — GEV*030 030 (60 Hz) 024 (50 Hz) 35 — — — — — 76-88 266-338 6-7 21-30 030 (60 Hz) 024 (50 Hz) 35 — — — — — 78-90 268-341 5-6 22-31 030 (60 Hz) 024 (50 Hz) 45 5.6 115-132 172-218 12-15 21-27 87-100 275-351 6-8 24-33 030 (60 Hz) 024 (50 Hz) 45 7.0 115-132 165-210 9-12 21-27 90-103 278-354 5-7 24-34 030 (60 Hz) 024 (50 Hz) 55 5.6 116-134 201-256 12-15 20-26 104-119 292-371 8-10 27-37 030 (60 Hz) 024 (50 Hz) 55 7.0 116-134 194-247 9-12 21-26 107-123 295-375 6-8 28-38 030 (60 Hz) 024 (50 Hz) 68 5.6 121-139 242-308 11-15 20-26 122-141 311-396 9-11 31-41 030 (60 Hz) 024 (50 Hz) 68 7.0 120-138 234-298 9-12 20-26 126-145 314-400 7-9 32-42 030 (60 Hz) 024 (50 Hz) 75 5.6 122-140 268-341 11-14 20-26 136-157 324-412 9-12 34-44 030 (60 Hz) 024 (50 Hz) 75 7.0 122-140 260-331 9-12 20-26 141-162 328-418 8-10 34-45 030 (60 Hz) 024 (50 Hz) 86 5.6 124-142 311-396 11-14 19-25 161-185 345-439 11-14 38-49 030 (60 Hz) 024 (50 Hz) 86 7.0 123-142 303-385 9-11 19-25 167-192 350-445 9-11 39-50 030 (60 Hz) 024 (50 Hz) 95 5.6 125-144 351-447 11-14 19-25 — — — — 030 (60 Hz) 024 (50 Hz) 95 7.0 125-144 342-436 9-11 19-25 — — — — 98 WSHP-SVX01N-EN Start-Up Table 54. Operating pressures in cooling/heating for GE* units (continued) Operating Data Model No. Entering Water Temp (°F) Water Flow (GPM) Cooling Heating Suction Discharge Water Air Temp Pressure Pressure Temp Rise Drop (psig) (psig) (°F) (°F DB) Suction Discharge Water Air Temp Pressure Pressure Temp Rise (psig) (psig) Drop (°F) (°F DB) GEH*036 036 (60 Hz) 030 (50 Hz) 35 — — — — — 76-88 294-375 6-8 21-30 036 (60 Hz) 030 (50 Hz) 45 6.7 115-132 174-222 12-15 20-26 89-102 306-390 7-9 24-34 036 (60 Hz) 030 (50 Hz) 45 8.4 115-132 168-214 9-12 20-26 91-105 309-394 6-7 24-34 036 (60 Hz) 030 (50 Hz) 55 6.7 117-134 203-259 11-15 19-25 106-122 327-416 8-11 27-37 036 (60 Hz) 030 (50 Hz) 55 8.4 116-134 196-250 9-12 20-25 108-125 329-419 7-9 28-38 036 (60 Hz) 030 (50 Hz) 68 6.7 120-138 244-311 11-14 19-25 126-145 351-446 10-12 32-42 036 (60 Hz) 030 (50 Hz) 68 8.4 119-137 237-301 9-11 19-25 130-150 354-450 8-10 32-43 036 (60 Hz) 030 (50 Hz) 75 6.7 121-139 270-343 11-14 19-25 141-162 367-468 10-13 34-45 036 (60 Hz) 030 (50 Hz) 75 8.4 121-139 262-333 9-11 19-25 145-167 372-473 9-11 35-46 036 (60 Hz) 030 (50 Hz) 86 6.7 124-142 312-397 11-14 18-24 165-190 395-503 12-15 39-50 036 (60 Hz) 030 (50 Hz) 86 8.4 124-142 303-386 9-11 19-24 172-197 399-508 10-12 40-51 036 (60 Hz) 030 (50 Hz) 95 6.7 126-145 351-447 11-14 18-24 — — — — 036 (60 Hz) 030 (50 Hz) 95 8.4 126-144 342-435 9-11 18-24 — — — — GEV*036 036 (60 Hz) 030 (50 Hz) 35 — — — — — 77-88 286-364 6-8 22-31 036 (60 Hz) 030 (50 Hz) 35 — — — — — 78-90 288-366 5-6 22-31 036 (60 Hz) 030 (50 Hz) 45 6.7 116-134 169-215 12-15 20-26 89-103 296-377 7-9 25-34 036 (60 Hz) 030 (50 Hz) 45 8.4 116-134 163-208 10-12 21-26 91-105 298-380 6-7 25-35 036 (60 Hz) 030 (50 Hz) 55 6.7 118-136 198-251 12-15 20-26 106-122 315-401 8-10 28-38 036 (60 Hz) 030 (50 Hz) 55 8.4 118-135 191-243 10-12 20-26 109-125 318-404 7-8 29-39 036 (60 Hz) 030 (50 Hz) 68 6.7 121-139 238-303 12-15 20-25 128-147 341-434 10-12 33-43 036 (60 Hz) 030 (50 Hz) 68 8.4 121-139 231-294 10-12 20-26 132-151 344-437 8-10 33-44 036 (60 Hz) 030 (50 Hz) 75 6.7 122-141 263-335 12-15 19-25 143-164 357-454 10-13 36-46 036 (60 Hz) 030 (50 Hz) 75 8.4 122-140 255-325 9-12 19-25 147-169 360-458 9-11 36-47 036 (60 Hz) 030 (50 Hz) 86 6.7 125-144 304-387 12-15 19-25 168-193 383-488 12-15 40-51 WSHP-SVX01N-EN 99 Start-Up Table 54. Operating pressures in cooling/heating for GE* units (continued) Operating Data Model No. Entering Water Temp (°F) Water Flow (GPM) Cooling Heating Suction Discharge Water Air Temp Pressure Pressure Temp Rise Drop (psig) (psig) (°F) (°F DB) Suction Discharge Water Air Temp Pressure Pressure Temp Rise (psig) (psig) Drop (°F) (°F DB) GEV*036 036 (60 Hz) 030 (50 Hz) 86 8.4 125-143 296-377 9-12 19-25 174-200 387-492 10-12 41-52 036 (60 Hz) 030 (50 Hz) 95 6.7 127-146 342-436 11-15 19-24 — — — — 036 (60 Hz) 030 (50 Hz) 95 8.4 127-146 334-425 9-12 19-25 — — — — GEH*042 042 (60 Hz) 036 (50 Hz) 35 — — — — — 74-86 269-342 6-7 20-30 042 (60 Hz) 036 (50 Hz) 35 — — — — — 76-87 270-344 5-6 21-30 042 (60 Hz) 036 (50 Hz) 45 7.8 116-134 173-220 12-16 21-27 86-99 281-358 7-8 23-33 042 (60 Hz) 036 (50 Hz) 45 9.8 116-134 167-212 10-13 21-27 88-101 283-360 5-7 24-33 042 (60 Hz) 036 (50 Hz) 55 7.8 118-135 201-256 12-15 21-26 102-118 298-379 8-10 27-36 042 (60 Hz) 036 (50 Hz) 55 9.8 118-135 194-247 10-12 21-26 105-121 300-382 6-8 27-37 042 (60 Hz) 036 (50 Hz) 68 7.8 122-140 242-308 12-15 20-26 121-140 317-403 9-11 31-41 042 (60 Hz) 036 (50 Hz) 68 9.8 121-140 235-299 10-12 21-26 125-144 321-408 7-9 31-42 042 (60 Hz) 036 (50 Hz) 75 7.8 123-141 267-340 12-15 20-26 135-156 331-422 10-12 33-44 042 (60 Hz) 036 (50 Hz) 75 9.8 123-141 259-330 9-12 20-26 140-161 336-427 8-10 34-45 042 (60 Hz) 036 (50 Hz) 86 7.8 125-144 308-392 12-15 20-25 159-183 355-451 11-14 38-49 042 (60 Hz) 036 (50 Hz) 86 9.8 125-144 300-382 9-12 20-26 165-190 359-457 9-12 39-50 042 (60 Hz) 036 (50 Hz) 95 7.8 127-146 346-441 11-15 19-25 — — — — 042 (60 Hz) 036 (50 Hz) 95 9.8 127-146 338-430 9-12 19-25 — — — — GEV*042 042 (60 Hz) 036 (50 Hz) 35 — — — — — 75-86 268-341 6-7 20-30 042 (60 Hz) 036 (50 Hz) 35 — — — — — 76-87 268-341 5-6 21-30 042 (60 Hz) 036 (50 Hz) 45 7.8 116-133 173-220 12-16 21-26 86-99 283-360 7-9 23-33 042 (60 Hz) 036 (50 Hz) 45 9.8 116-133 167-212 10-12 21-27 88-102 283-360 6-7 24-33 042 (60 Hz) 036 (50 Hz) 55 7.8 117-135 201-256 12-15 20-26 103-118 298-380 8-10 27-37 042 (60 Hz) 036 (50 Hz) 55 9.8 117-135 194-247 10-12 20-26 105-121 301-383 6-8 27-37 100 WSHP-SVX01N-EN Start-Up Table 54. Operating pressures in cooling/heating for GE* units (continued) Operating Data Model No. Entering Water Temp (°F) Water Flow (GPM) Cooling Heating Suction Discharge Water Air Temp Pressure Pressure Temp Rise Drop (psig) (psig) (°F) (°F DB) Suction Discharge Water Air Temp Pressure Pressure Temp Rise (psig) (psig) Drop (°F) (°F DB) GEV*042 042 (60 Hz) 036 (50 Hz) 68 7.8 122-140 242-308 12-15 20-26 122-140 318-404 9-12 31-41 042 (60 Hz) 036 (50 Hz) 68 9.8 121-140 234-298 9-12 20-26 126-144 321-409 7-9 31-42 042 (60 Hz) 036 (50 Hz) 75 7.8 123-141 267-340 12-15 20-25 136-156 331-422 10-13 33-44 042 (60 Hz) 036 (50 Hz) 75 9.8 122-141 259-330 9-12 20-26 140-161 336-427 8-10 34-45 042 (60 Hz) 036 (50 Hz) 86 7.8 126-144 307-390 11-15 19-25 160-184 355-452 11-14 38-49 042 (60 Hz) 036 (50 Hz) 86 9.8 125-144 299-380 9-12 19-25 166-190 359-457 9-12 39-50 042 (60 Hz) 036 (50 Hz) 95 7.8 127-147 345-439 11-14 18-24 — — — — 042 (60 Hz) 036 (50 Hz) 95 9.8 127-146 337-428 9-11 18-24 — — — — GEH*048 048 (60 Hz) 042 (50 Hz) 35 — — — — — 74-85 263-334 6-8 20-29 048 (60 Hz) 042 (50 Hz) 35 — — — — — 76-87 265-337 5-6 20-29 048 (60 Hz) 042 (50 Hz) 45 9.0 120-138 184-234 13-16 23-29 85-98 273-348 7-9 23-32 048 (60 Hz) 042 (50 Hz) 45 11.2 120-138 176-225 10-13 23-29 87-100 275-350 6-7 23-33 048 (60 Hz) 042 (50 Hz) 55 9.0 121-140 214-273 13-16 23-28 101-117 289-368 8-10 26-36 048 (60 Hz) 042 (50 Hz) 55 11.2 121-139 206-262 10-13 23-28 104-120 292-372 6-8 26-36 048 (60 Hz) 042 (50 Hz) 68 9.0 125-144 256-326 13-16 22-28 117-135 305-388 9-12 30-40 048 (60 Hz) 042 (50 Hz) 68 11.2 125-144 247-315 10-13 23-28 122-140 310-394 7-10 30-41 048 (60 Hz) 042 (50 Hz) 75 9.0 126-146 282-359 12-16 22-28 131-151 318-405 10-13 32-43 048 (60 Hz) 042 (50 Hz) 75 11.2 126-145 273-348 10-13 22-28 136-156 322-410 8-10 33-44 048 (60 Hz) 042 (50 Hz) 86 9.0 129-148 324-412 12-15 21-27 154-177 339-431 11-14 36-47 048 (60 Hz) 042 (50 Hz) 86 11.2 128-147 314-400 10-12 22-27 160-184 344-437 9-12 37-48 048 (60 Hz) 042 (50 Hz) 95 9.0 130-150 364-463 12-15 21-27 — — — — 048 (60 Hz) 042 (50 Hz) 95 11.2 130-149 354-451 10-12 21-27 — — — — WSHP-SVX01N-EN 101 Start-Up Table 54. Operating pressures in cooling/heating for GE* units (continued) Operating Data Model No. Entering Water Temp (°F) Water Flow (GPM) Cooling Heating Suction Discharge Water Air Temp Pressure Pressure Temp Rise Drop (psig) (psig) (°F) (°F DB) Suction Discharge Water Air Temp Pressure Pressure Temp Rise (psig) (psig) Drop (°F) (°F DB) GEV*048 048 (60 Hz) 042 (50 Hz) 35 — — — — — 63-73 248-315 5-7 19-28 048 (60 Hz) 042 (50 Hz) 35 — — — — — 64-74 249-316 4-5 19-28 048 (60 Hz) 042 (50 Hz) 45 9.0 120-138 184-234 13-16 22-28 72-82 257-327 6-8 21-30 048 (60 Hz) 042 (50 Hz) 45 11.2 119-137 177-225 10-13 22-28 73-84 259-329 5-6 21-30 048 (60 Hz) 042 (50 Hz) 55 9.0 121-139 214-272 13-16 22-27 86-99 270-344 7-9 24-33 048 (60 Hz) 042 (50 Hz) 55 11.2 121-139 206-262 10-13 22-27 88-101 272-347 6-7 24-34 048 (60 Hz) 042 (50 Hz) 68 9.0 125-144 255-325 12-16 21-27 102-118 287-366 8-10 27-37 048 (60 Hz) 042 (50 Hz) 68 11.2 125-144 246-314 10-13 21-27 105-120 290-369 7-8 28-38 048 (60 Hz) 042 (50 Hz) 75 9.0 126-145 281-358 12-16 21-27 114-131 299-381 9-11 30-40 048 (60 Hz) 042 (50 Hz) 75 11.2 126-145 272-346 10-13 21-27 117-135 302-384 7-9 30-41 048 (60 Hz) 042 (50 Hz) 86 9.0 129-149 323-412 12-16 20-26 136-156 318-405 10-13 34-44 048 (60 Hz) 042 (50 Hz) 86 11.2 129-148 314-399 10-12 21-26 140-161 321-409 8-10 34-45 048 (60 Hz) 042 (50 Hz) 95 9.0 131-151 363-462 12-15 20-26 — — — — 048 (60 Hz) 042 (50 Hz) 95 11.2 131-150 353-449 10-12 20-26 — — — — GEH*060 060(60 Hz) 048 (50 Hz) 35 — — — — — 69-79 265-337 6-7 20-30 060(60 Hz) 048 (50 Hz) 35 — — — — — 70-81 267-339 5-6 21-30 060(60 Hz) 048 (50 Hz) 45 11.2 111-128 176-225 13-16 21-26 79-91 274-348 6-8 23-32 060(60 Hz) 048 (50 Hz) 45 14.0 108-124 170-217 10-13 21-27 81-93 275-350 5-7 23-32 060(60 Hz) 048 (50 Hz) 55 11.2 113-129 205-261 12-16 20-26 95-109 290-369 7-9 26-36 060(60 Hz) 048 (50 Hz) 55 14.0 112-129 198-252 10-13 20-26 97-111 291-371 6-8 26-36 060(60 Hz) 048 (50 Hz) 68 11.2 117-135 243-309 12-16 20-26 115-132 311-396 9-11 30-40 060(60 Hz) 048 (50 Hz) 68 14.0 117-134 235-300 10-12 20-26 118-136 314-399 7-9 31-41 060(60 Hz) 048 (50 Hz) 75 11.2 118-136 268-342 12-15 20-25 128-147 324-412 10-12 33-43 060(60 Hz) 048 (50 Hz) 75 14.0 118-136 260-331 10-12 20-26 132-152 327-416 8-10 33-44 102 WSHP-SVX01N-EN Start-Up Table 54. Operating pressures in cooling/heating for GE* units (continued) Operating Data Model No. Entering Water Temp (°F) Water Flow (GPM) Cooling Heating Suction Discharge Water Air Temp Pressure Pressure Temp Rise Drop (psig) (psig) (°F) (°F DB) Suction Discharge Water Air Temp Pressure Pressure Temp Rise (psig) (psig) Drop (°F) (°F DB) GEH*060 060(60 Hz) 048 (50 Hz) 86 11.2 121-139 309-393 12-15 19-25 151-174 347-442 11-14 37-48 060(60 Hz) 048 (50 Hz) 86 14.0 121-139 301-383 10-12 19-25 157-180 351-447 9-11 38-49 060(60 Hz) 048 (50 Hz) 95 11.2 123-141 348-442 12-15 19-25 — — — — 060(60 Hz) 048 (50 Hz) 95 14.0 122-141 339-431 9-12 19-25 — — — — GEV*060 060(60 Hz) 048 (50 Hz) 35 — — — — — 70-81 261-332 6-7 20-30 060(60 Hz) 048 (50 Hz) 35 — — — — — 72-82 262-333 5-6 20-30 060(60 Hz) 048 (50 Hz) 45 11.2 115-133 178-227 13-16 21-27 80-92 269-342 6-8 23-32 060(60 Hz) 048 (50 Hz) 45 14.0 115-132 172-219 10-13 21-27 82-94 270-344 5-7 23-32 060(60 Hz) 048 (50 Hz) 55 11.2 117-134 207-264 12-16 20-26 95-110 284-362 7-10 26-36 060(60 Hz) 042 (50 Hz) 55 14.0 117-134 200-255 10-13 21-26 97-112 286-364 6-8 26-36 060(60 Hz) 048 (50 Hz) 68 11.2 122-140 248-315 12-16 20-26 116-134 304-387 9-11 31-41 060(60 Hz) 048 (50 Hz) 68 14.0 121-140 240-305 10-13 21-26 120-138 308-392 7-9 31-42 060(60 Hz) 048 (50 Hz) 75 11.2 123-141 273-347 12-16 20-26 129-149 318-404 10-12 33-44 060(60 Hz) 048 (50 Hz) 75 14.0 123-141 265-337 10-12 20-26 134-154 321-408 8-10 34-45 060(60 Hz) 048 (50 Hz) 86 11.2 125-144 313-399 12-15 20-25 153-176 341-434 11-14 38-49 060(60 Hz) 048 (50 Hz) 86 14.0 125-144 305-388 10-12 20-25 158-182 344-438 9-12 38-50 060(60 Hz) 048 (50 Hz) 95 11.2 127-146 352-447 12-15 19-25 — — — — 060(60 Hz) 048 (50 Hz) 95 14.0 127-146 343-436 9-12 19-25 — — — — 072 (60 Hz) 32 12 — — — — 67 - 77 250 - 319 6-8 20 - 24 072 (60 Hz) 32 18 — — — — 70 - 80 253 - 322 4-5 20 - 25 072 (60 Hz) 45 12 129 - 148 176 - 224 15 - 18 25 - 30 85 - 97 266 - 338 8 - 10 24 - 29 072 (60 Hz) 45 18 128 - 148 163 - 208 10 - 12 25 - 31 89 - 103 269 - 342 5-7 25 - 30 072 (60 Hz) 55 12 130 - 150 205 - 260 14 - 18 24 - 30 102 - 117 281 - 357 8 - 11 28 - 35 072 (60 Hz) 55 18 130 - 149 191 - 243 10 - 12 24 - 30 107 - 123 285 - 362 6-7 29 - 35 072 (60 Hz) 68 12 133 - 153 247 - 314 14 - 18 23 - 29 125 - 144 300 - 382 10 - 13 34 - 42 072 (60 Hz) 68 18 132 - 152 232 - 296 9 - 12 24 - 29 133 - 153 305 - 388 7-9 35 - 43 072 (60 Hz) 77 12 134 - 155 286 - 363 15 - 18 23 - 28 139 - 160 311 - 396 11 - 14 37 - 45 GEH*/GEV* WSHP-SVX01N-EN 103 Start-Up Table 54. Operating pressures in cooling/heating for GE* units (continued) Operating Data Cooling Heating Suction Discharge Water Air Temp Pressure Pressure Temp Rise Drop (psig) (psig) (°F) (°F DB) Suction Discharge Water Air Temp Pressure Pressure Temp Rise (psig) (psig) Drop (°F) (°F DB) Model No. Entering Water Temp (°F) Water Flow (GPM) 072 (60 Hz) 77 18 134 - 154 268 - 341 10 - 12 23 - 29 148 - 170 317 - 403 8 - 10 38 - 47 072 (60 Hz) 86 12 136 - 156 317 - 403 14 - 17 22 - 28 163 - 188 329 - 419 13 - 16 41 - 50 072 (60 Hz) 86 18 135 - 155 300 - 382 9 - 12 23 - 28 175 - 201 335 - 427 9 - 11 43 - 53 072 (60 Hz) 95 12 137 - 158 356 - 453 13 - 17 22 - 27 — — — — 072 (60 Hz) 95 18 137 - 157 340 - 432 9 - 11 22 - 27 — — — — 090 (60 Hz) 072 (50 Hz) 32 15 — — — — 65 - 75 245 - 312 6-8 22 - 27 090 (60 Hz) 072 (50 Hz) 32 22.5 — — — — 68 - 78 248 - 316 4-5 23 - 28 090 (60 Hz) 072 (50 Hz) 45 15 125 - 144 183 - 233 15 - 19 24 - 30 83 - 95 260 - 331 8 - 10 26 - 31 090 (60 Hz) 072 (50 Hz) 45 22.5 124 - 143 170 - 216 10 - 12 24 - 30 87 - 101 263 - 335 5-7 26 - 32 090 (60 Hz) 072 (50 Hz) 55 15 126 - 145 213 - 271 14 - 18 24 - 29 100 - 115 274 - 348 8 - 11 29 - 36 090 (60 Hz) 072 (50 Hz) 55 22.5 126 - 145 198 - 252 10 - 12 24 - 29 105 - 121 277 - 353 6-7 30 - 37 090 (60 Hz) 072 (50 Hz) 68 15 128 - 148 257 - 327 14 - 18 23 - 28 123 - 142 291 - 370 10 - 13 34 - 42 090 (60 Hz) 072 (50 Hz) 68 22.5 128 - 147 241 - 307 9 - 12 23 - 29 131 - 150 296 - 376 7-9 35 - 43 090 (60 Hz) 072 (50 Hz) 77 15 130 - 150 298 - 379 15 - 19 23 - 28 137 - 158 301 - 383 11 - 14 37 - 45 090 (60 Hz) 072 (50 Hz) 77 22.5 130 - 149 279 - 355 10 - 12 23 - 28 146 - 168 306 - 390 8 - 10 38 - 47 090 (60 Hz) 072 (50 Hz) 86 15 131 - 151 328 - 418 14 - 17 22 - 27 161 - 185 317 - 403 13 - 16 40 - 50 090 (60 Hz) 072 (50 Hz) 86 22.5 131 - 151 311 - 396 9 - 12 22 - 28 173 - 199 324 - 412 9 - 11 42 - 52 090 (60 Hz) 072 (50 Hz) 95 15 133 - 153 370 - 471 13 - 17 22 - 27 — — — — 090 (60 Hz) 072 (50 Hz) 95 22.5 133 - 153 352 - 448 9 - 11 22 - 27 — — — — 120 (60 Hz) 090 (50 Hz) 32 20 — — — — 65 - 75 246 - 313 6-7 25 - 30 120 (60 Hz) 090 (50 Hz) 32 30 — — — — 68 - 79 248 - 316 4-5 25 - 31 120 (60 Hz) 090 (50 Hz) 45 20 124 - 143 174 - 221 14 - 18 23 - 29 84 - 96 259 - 330 7-9 28 - 34 120 (60 Hz) 090 (50 Hz) 45 30 123 - 142 162 - 206 9 - 12 23 - 29 88 - 101 263 - 335 5-6 28 - 34 120 (60 Hz) 090 (50 Hz) 55 20 125 - 144 202 - 258 14 - 18 23 - 29 101 - 116 274 - 349 8 - 10 30 - 37 120 (60 Hz) 090 (50 Hz) 55 30 125 - 144 189 - 241 9 - 12 23 - 29 106 - 122 279 - 355 6-7 31 - 38 120 (60 Hz) 090 (50 Hz) 68 20 127 - 146 244 - 311 13 - 17 23 - 28 124 - 143 292 - 372 10 - 12 34 - 42 120 (60 Hz) 090 (50 Hz) 68 30 127 - 146 230 - 293 9 - 11 23 - 28 132 - 152 297 - 378 7-8 35 - 43 120 (60 Hz) 090 (50 Hz) 77 20 129 - 148 281 - 358 14 - 18 23 - 28 139 - 159 303 - 385 10 - 13 37 - 45 GEH*/GEV* 104 WSHP-SVX01N-EN Start-Up Table 54. Operating pressures in cooling/heating for GE* units (continued) Operating Data Model No. Entering Water Temp (°F) Water Flow (GPM) Cooling Heating Suction Discharge Water Air Temp Pressure Pressure Temp Rise Drop (psig) (psig) (°F) (°F DB) Suction Discharge Water Air Temp Pressure Pressure Temp Rise (psig) (psig) Drop (°F) (°F DB) GEH*/GEV* 120 (60 Hz) 090 (50 Hz) 77 30 128 - 148 265 - 337 9 - 12 23 - 28 147 - 170 308 - 392 7-9 37 - 46 120 (60 Hz) 090 (50 Hz) 86 20 130 - 150 311 - 396 13 - 16 22 - 27 163 - 187 320 - 407 12 - 15 40 - 50 120 (60 Hz) 090 (50 Hz) 86 30 130 - 150 296 - 376 9 - 11 22 - 27 174 - 200 326 - 415 8 - 11 41 - 51 120 (60 Hz) 090 (50 Hz) 95 20 132 - 152 348 - 443 13 - 16 22 - 27 — — — — 120 (60 Hz) 090 (50 Hz) 95 30 132 - 152 333 - 423 8 - 11 22 - 27 — — — — 150 (60 Hz) 120 (50 Hz) 32 25 — — — — 66 - 75 256 - 326 7-8 23 - 29 150 (60 Hz) 120 (50 Hz) 32 37.5 — — — — 69 - 79 258 - 329 5-6 24 - 30 150 (60 Hz) 120 (50 Hz) 45 25 120 - 138 187 - 238 15 - 19 22 - 29 84 - 96 272 - 346 8 - 10 26 - 32 150 (60 Hz) 120 (50 Hz) 45 37.5 120 - 138 172 - 219 10 - 12 22 - 29 88 - 102 275 - 350 6-7 26 - 32 150 (60 Hz) 120 (50 Hz) 55 25 122 - 140 216 - 275 14 - 18 22 - 28 101 - 116 290 - 369 9 - 11 28 - 35 150 (60 Hz) 120 (50 Hz) 55 37.5 121 - 140 200 - 255 10 - 12 22 - 28 107 - 123 293 - 372 6-8 29 - 37 150 (60 Hz) 120 (50 Hz) 68 25 124 - 143 259 - 329 14 - 18 22 - 28 124 - 143 310 - 395 11 - 14 32 - 40 150 (60 Hz) 120 (50 Hz) 68 37.5 124 - 142 242 - 308 9 - 12 22 - 28 132 - 152 315 - 401 7-9 33 - 42 150 (60 Hz) 120 (50 Hz) 77 25 126 - 145 300 - 382 14 - 18 22 - 28 138 - 159 323 - 411 12 - 15 34 - 43 150 (60 Hz) 120 (50 Hz) 77 37.5 125 - 144 280 - 356 10 - 12 22 - 28 148 - 170 328 - 418 8 - 10 36 - 45 150 (60 Hz) 120 (50 Hz) 86 25 128 - 147 328 - 417 13 - 17 21 - 27 162 - 187 344 - 438 13 - 17 37 - 47 150 (60 Hz) 120 (50 Hz) 86 37.5 127 - 146 309 - 393 9 - 11 22 - 27 174 - 201 351 - 446 9 - 12 39 - 49 150 (60 Hz) 120 (50 Hz) 95 25 129 - 149 366 - 466 13 - 17 21 - 27 — — — — 150 (60 Hz) 120 (50 Hz) 95 37.5 129 - 148 348 - 442 9 - 11 21 - 27 — — — — 180 (60 Hz) 150 (50 Hz) 32 30 — — — — 62 - 71 260 - 331 7-9 23 - 29 180 (60 Hz) 150 (50 Hz) 32 45 — — — — 65 - 75 263 - 334 5-6 24 - 30 180 (60 Hz) 150 (50 Hz) 45 30 119 - 136 189 - 240 15 - 19 22 - 29 79 - 91 277 - 352 8 - 10 26 - 32 180 (60 Hz) 150 (50 Hz) 45 45 118 - 136 172 - 219 10 - 13 22 - 29 84 - 97 280 - 356 6-7 27 - 33 180 (60 Hz) 150 (50 Hz) 55 30 120 - 138 220 - 280 15 - 19 22 - 28 96 - 111 294 - 375 9 - 11 29 - 36 180 (60 Hz) 150 (50 Hz) 55 45 120 - 138 205 - 261 10 - 12 22 - 28 102 - 117 297 - 378 6-8 30 - 37 180 (60 Hz) 150 (50 Hz) 68 30 122 - 140 266 - 338 14 - 18 22 - 28 119 - 137 316 - 402 11 - 14 32 - 41 WSHP-SVX01N-EN 105 Start-Up Table 54. Operating pressures in cooling/heating for GE* units (continued) Operating Data Model No. Entering Water Temp (°F) Water Flow (GPM) Cooling Heating Suction Discharge Water Air Temp Pressure Pressure Temp Rise Drop (psig) (psig) (°F) (°F DB) Suction Discharge Water Air Temp Pressure Pressure Temp Rise (psig) (psig) Drop (°F) (°F DB) GEH*/GEV* 180 (60 Hz) 150 (50 Hz) 68 45 121 - 140 249 - 317 10 - 12 22 - 28 127 - 146 320 - 407 7-9 34 - 43 180 (60 Hz) 150 (50 Hz) 77 30 123 - 142 308 - 392 15 - 19 22 - 28 133 - 153 329 - 419 12 - 15 35 - 43 180 (60 Hz) 150 (50 Hz) 77 45 123 - 141 288 - 367 10 - 13 22 - 28 142 - 163 334 - 425 8 - 10 36 - 46 180 (60 Hz) 150 (50 Hz) 86 30 124 - 143 340 - 432 14 - 18 21 - 27 156 - 179 351 - 447 13 - 17 38 - 48 180 (60 Hz) 150 (50 Hz) 86 45 124 - 143 321 - 409 9 - 12 21 - 27 167 - 192 357 - 455 9 - 12 40 - 50 180 (60 Hz) 150 (50 Hz) 95 30 126 - 145 381 - 485 14 - 17 21 - 27 — — — — 180 (60 Hz) 150 (50 Hz) 95 45 126 - 145 363 - 461 9 - 12 21 - 27 — — — — 240 (60 Hz) 180 (50 Hz) 32 40 — — — — 64 - 73 256 - 326 6-8 25 - 31 240 (60 Hz) 180 (50 Hz) 32 60 — — — — 67 - 77 259 - 329 4-5 26 - 32 240 (60 Hz) 180 (50 Hz) 45 40 126 - 145 178 - 226 15 - 19 23 - 29 82 - 94 270 - 344 7-9 27 - 34 240 (60 Hz) 180 (50 Hz) 45 60 125 - 144 165 - 210 10 - 12 23 - 29 86 - 99 274 - 349 5-7 28 - 35 240 (60 Hz) 180 (50 Hz) 55 40 127 - 146 208 - 265 14 - 18 23 - 29 99 - 113 285 - 362 8 - 10 29 - 37 240 (60 Hz) 180 (50 Hz) 55 60 127 - 146 194 - 247 10 - 12 23 - 29 104 - 120 289 - 368 6-7 30 - 38 240 (60 Hz) 180 (50 Hz) 68 40 129 - 148 253 - 321 14 - 18 22 - 29 122 - 140 303 - 386 10 - 13 33 - 41 240 (60 Hz) 180 (50 Hz) 68 60 129 - 148 237 - 301 9 - 12 23 - 29 129 - 149 309 - 394 7-9 34 - 42 240 (60 Hz) 180 (50 Hz) 77 40 131 - 150 294 - 374 15 - 19 22 - 28 135 - 156 315 - 400 11 - 14 34 - 43 240 (60 Hz) 180 (50 Hz) 77 60 130 - 150 275 - 350 10 - 12 22 - 28 144 - 166 322 - 409 8 - 10 36 - 45 240 (60 Hz) 180 (50 Hz) 86 40 132 - 152 325 - 414 14 - 17 22 - 28 159 - 183 334 - 425 12 - 16 37 - 47 240 (60 Hz) 180 (50 Hz) 86 60 132 - 152 308 - 392 9 - 12 22 - 28 170 - 196 342 - 436 9 - 11 39 - 49 240 (60 Hz) 180 (50 Hz) 95 40 134 - 154 367 - 467 13 - 17 22 - 27 — — — — 240 (60 Hz) 180 (50 Hz) 95 60 134 - 154 349 - 444 9 - 11 22 - 28 — — — — 300 (60 Hz) 240 (50 Hz) 32 50 — — — — 62 - 71 275 - 350 6-8 24 - 30 300 (60 Hz) 240 (50 Hz) 32 75 — — — — 65 - 75 279 - 355 4-6 25 - 31 300 (60 Hz) 240 (50 Hz) 45 50 120 - 138 181 - 231 15 - 19 22 - 28 80 - 92 291 - 370 8 - 10 26 - 33 300 (60 Hz) 240 (50 Hz) 45 75 119 - 137 169 - 215 10 - 13 22 - 28 84 - 97 295 - 376 5-7 27 - 34 300 (60 Hz) 240 (50 Hz) 55 50 121 - 140 209 - 267 14 - 18 22 - 28 96 - 111 309 - 394 8 - 11 29 - 36 106 WSHP-SVX01N-EN Start-Up Table 54. Operating pressures in cooling/heating for GE* units (continued) Operating Data Model No. Entering Water Temp (°F) Water Flow (GPM) Cooling Heating Suction Discharge Water Air Temp Pressure Pressure Temp Rise Drop (psig) (psig) (°F) (°F DB) Suction Discharge Water Air Temp Pressure Pressure Temp Rise (psig) (psig) Drop (°F) (°F DB) GEH*/GEV* 300 (60 Hz) 240 (50 Hz) 55 75 121 - 139 196 - 249 10 - 12 22 - 28 102 - 117 314 - 399 6-8 30 - 37 300 (60 Hz) 240 (50 Hz) 68 50 124 - 142 251 - 320 14 - 18 22 - 27 119 - 137 330 - 420 10 - 13 32 - 40 300 (60 Hz) 240 (50 Hz) 68 75 123 - 142 236 - 301 9 - 12 22 - 27 127 - 146 335 - 427 7-9 33 - 42 300 (60 Hz) 240 (50 Hz) 77 50 126 - 145 289 - 368 15 - 18 21 - 27 133 - 153 342 - 435 11 - 14 34 - 43 300 (60 Hz) 240 (50 Hz) 77 75 125 - 144 272 - 346 10 - 12 21 - 27 142 - 163 348 - 443 8 - 10 35 - 45 300 (60 Hz) 240 (50 Hz) 86 50 127 - 147 319 - 406 13 - 17 21 - 27 156 - 180 362 - 461 13 - 16 37 - 46 300 (60 Hz) 240 (50 Hz) 86 75 127 - 146 302 - 385 9 - 11 21 - 27 168 - 193 371 - 472 9 - 11 39 - 49 300 (60 Hz) 240 (50 Hz) 95 50 130 - 149 357 - 454 13 - 17 21 - 26 — — — — 300 (60 Hz) 240 (50 Hz) 95 75 129 - 148 340 - 433 9 - 11 21 - 26 — — — — Table 55. Operating pressures in cooling/heating for EX* units Operating Data Cooling Model EXH*006 (60 Hz) Heating Entering water temp (ºF) Water flow (GPM) 35 1.4 35 1.7 — — — 45 1.4 143-165 190-243 13-16 45 1.7 143-164 184-235 11-13 55 1.4 145-167 217-277 55 1.7 144-166 68 1.4 148-171 68 1.7 75 Suction Discharge Water pressure pressure temp rise (psig) (psig) (ºF) — — — Suction Discharge Water Air temp pressure pressure Temp drop rise (psig) (psig) (ºF) (ºF DB) 94-108 279-355 6-8 23-29 — 96-110 281-357 5-6 23-29 24-30 110-127 297-377 7-9 26-34 24-31 113-130 300-382 6-8 27-34 13-16 23-30 128-147 317-404 8-10 30-39 210-268 11-13 24-30 131-151 320-407 7-9 31-39 254-324 12-15 23-29 154-177 345-439 10-12 35-45 147-170 244-312 10-13 23-29 158-182 349-444 8-10 36-45 1.4 148-171 281-358 12-15 23-29 169-195 361-459 10-13 38-48 75 1.7 148-170 273-348 10-13 23-29 175-201 366-466 9-11 38-48 86 1.4 149-172 328-418 12-15 22-28 197-226 388-494 11-15 41-52 86 1.7 149-172 320-407 10-13 23-29 203-234 395-502 10-12 41-52 95 1.4 151-173 373-474 12-15 22-28 — — — — 95 1.7 150-173 363-462 10-13 22-28 — — — — 35 1.7 — — — — 93-107 272-346 6-7 20-26 WSHP-SVX01N-EN — Air temp drop (ºF DB) 107 Start-Up Table 55. Operating pressures in cooling/heating for EX* units (continued) Operating Data Cooling Model EXH*009 (60 Hz) EXH*012 (60 Hz) EXH*015 (60 Hz) 108 Heating Entering water temp (ºF) Water flow (GPM) 35 2.1 — — — — 95-110 274-348 5-6 21-27 45 1.7 142-164 187-238 13-16 22-28 109-126 288-366 7-9 24-30 45 2.1 142-164 181-230 11-14 22-27 112-129 291-370 6-7 24-31 55 1.7 144-166 214-272 12-15 21-27 127-146 305-388 8-10 27-34 55 2.1 144-166 207-263 10-13 21-27 130-150 309-393 7-8 27-35 68 1.7 146-168 258-328 12-15 20-26 153-176 330-420 9-12 31-39 68 2.1 146-168 250-318 10-12 21-26 157-181 335-427 8-10 32-40 75 1.7 147-169 286-363 12-15 20-25 168-193 345-439 10-13 33-42 75 2.1 147-169 277-352 9-12 20-26 174-200 350-446 8-11 34-43 86 1.7 149-171 336-427 12-15 19-25 195-224 370-471 11-14 36-46 86 2.1 148-171 326-415 9-12 20-25 202-232 375-477 9-12 37-47 95 1.7 149-172 386-491 12-15 19-24 — — — — 95 2.1 149-172 375-477 9-12 19-24 — — — — 35 2.2 — — — — 92-106 288-367 10-13 21-27 35 2.8 — — — — 95-109 290-370 8-11 21-27 45 2.2 142-163 183-233 12-15 22-28 108-125 304-387 12-15 24-30 45 2.8 142-163 175-223 9-12 23-29 111-128 307-391 9-12 24-31 55 2.2 143-164 212-270 12-15 21-27 126-145 322-410 13-16 26-33 55 2.8 143-164 204-260 9-12 22-27 130-149 325-413 10-13 27-34 68 2.2 144-166 257-327 12-15 21-26 152-174 346-441 14-18 29-37 68 2.8 144-166 248-316 9-12 21-26 157-180 352-448 11-15 29-37 75 2.2 145-167 284-361 12-15 20-26 167-192 361-460 15-19 30-38 75 2.8 145-167 274-349 9-12 20-26 173-199 366-466 12-15 30-39 86 2.2 146-168 332-422 12-15 19-25 194-223 384-489 16-21 32-40 86 2.8 146-168 321-409 9-12 20-25 201-231 390-497 13-17 32-41 95 2.2 147-170 376-478 12-15 19-24 — — — — 95 2.8 147-170 365-465 9-12 19-24 — — — — 35 2.8 — — — — 91-105 296-377 6-7 20-25 35 3.5 — — — — 93-107 299-380 5-6 20-26 45 2.8 138-159 180-230 11-14 22-28 107-123 313-398 7-8 23-29 45 3.5 138-158 174-221 9-11 22-27 109-126 316-402 5-7 23-30 55 2.8 139-159 210-267 11-14 21-27 124-143 332-423 8-10 26-33 55 3.5 138-159 203-258 9-11 21-27 128-147 336-427 6-8 27-34 68 2.8 140-161 254-324 11-14 20-26 150-172 358-456 9-11 30-38 68 3.5 140-161 246-313 9-11 21-26 154-178 364-463 7-9 30-39 75 2.8 141-162 281-358 11-14 20-25 165-190 373-475 10-12 32-40 75 3.5 140-162 272-347 9-11 20-26 171-196 379-483 8-10 32-41 86 2.8 142-163 328-417 11-14 19-25 191-220 399-508 11-14 34-43 86 3.5 142-163 318-405 9-11 20-25 198-228 405-515 9-11 34-44 95 2.8 143-165 371-472 11-14 19-24 — — — — 95 3.5 143-165 361-459 9-11 19-24 — — — — Suction Discharge Water pressure pressure temp rise (psig) (psig) (ºF) Air temp drop (ºF DB) Suction Discharge Water Air temp pressure pressure Temp drop rise (psig) (psig) (ºF) (ºF DB) WSHP-SVX01N-EN Start-Up Table 55. Operating pressures in cooling/heating for EX* units (continued) Operating Data Cooling Model EXH*018 (60 Hz) EXH*024 (60 Hz) EXH*030 (60 Hz) Heating Entering water temp (ºF) Water flow (GPM) 35 3.3 — — — — 91-104 282-357 6-7 21-26 35 4.2 — — — — 93-107 285-360 5-6 21-27 45 3.3 143-164 158-206 12-15 23-29 106-122 306-385 7-9 24-30 45 4.2 142-164 151-197 9-12 23-29 109-125 309-388 5-7 24-31 55 3.3 142-164 186-242 12-15 23-29 123-141 323-407 8-10 27-34 55 4.2 143-164 179-233 9-12 23-29 127-146 326-411 6-8 27-35 68 3.3 143-164 226-294 12-15 22-28 148-171 357-447 9-12 31-39 68 4.2 142-164 218-283 9-12 22-28 153-176 361-452 8-10 32-40 75 3.3 143-164 252-326 12-15 21-27 164-188 370-464 10-13 33-42 75 4.2 143-164 243-315 9-12 21-27 169-195 375-470 8-10 34-43 86 3.3 143-165 295-382 12-15 20-26 191-219 389-488 11-14 36-46 86 4.2 143-165 286-370 9-12 20-26 198-228 392-492 9-11 37-47 95 3.3 144-166 336-433 12-15 19-24 — — — — 95 4.2 144-166 326-421 9-12 19-25 — — — — 35 4.4 — — — — 84-97 276-348 5-7 21-27 35 5.6 — — — — 86-99 278-350 4-5 22-28 45 4.4 134-154 164-214 12-15 23-30 99-114 296-372 6-8 25-32 45 5.6 132-152 157-205 9-12 23-30 101-116 298-375 5-6 26-32 55 4.4 134-154 191-249 12-15 22-28 115-132 311-391 7-9 29-36 55 5.6 134-154 184-239 9-12 22-29 118-136 314-395 6-7 29-37 68 4.4 135-156 231-300 12-15 21-27 139-160 342-428 9-11 33-42 68 5.6 135-155 224-290 9-12 22-28 143-165 346-433 7-9 33-42 75 4.4 136-157 256-331 12-15 21-27 153-176 355-444 9-12 35-44 75 5.6 136-156 248-321 9-12 21-27 159-182 360-450 8-10 35-45 86 4.4 137-158 298-385 11-14 20-26 178-205 376-471 11-13 37-47 86 5.6 137-158 289-374 9-11 20-26 185-213 380-476 9-11 38-48 95 4.4 139-160 336-434 11-14 19-25 — — — — Suction Discharge Water pressure pressure temp rise (psig) (psig) (ºF) Air temp drop (ºF DB) Suction Discharge Water Air temp pressure pressure Temp drop rise (psig) (psig) (ºF) (ºF DB) 95 5.6 138-159 328-422 9-11 20-25 — — — — 35 5.5 — — — — 88-102 269-342 5-7 20-25 35 7.0 — — — — 91-105 271-344 4-6 20-26 45 5.5 138-159 164-214 12-15 22-28 104-120 287-364 7-8 23-29 45 7.0 140-161 157-205 10-12 22-27 107-123 290-367 5-7 23-30 55 5.5 142-164 191-249 12-15 21-27 121-139 303-384 8-10 26-33 55 7.0 142-163 184-240 9-12 21-27 125-144 307-388 6-8 27-34 68 5.5 144-165 230-299 12-15 20-26 146-168 333-420 9-11 30-38 68 7.0 143-165 222-289 9-12 21-26 151-174 337-426 7-9 30-39 75 5.5 144-166 255-331 12-15 20-25 161-185 347-438 10-13 32-40 75 7.0 143-165 248-322 9-12 20-26 167-192 352-444 8-10 32-41 86 5.5 146-168 297-384 11-15 19-25 187-215 368-465 11-14 34-43 86 7.0 145-167 288-373 9-11 20-25 194-223 374-473 9-11 34-44 95 5.5 147-169 336-434 11-14 19-24 — — — — 95 7.0 146-169 327-423 9-11 19-24 — — — — WSHP-SVX01N-EN 109 Start-Up Table 55. Operating pressures in cooling/heating for EX* units (continued) Operating Data Cooling Model EXH*036 (60 Hz) EXH*042 (60 Hz) EXH*048 (60 Hz) 110 Heating Entering water temp (ºF) Water flow (GPM) 35 6.6 — — — — 88-102 289-364 6-7 19-24 35 8.4 — — — — 90-104 291-366 5-6 19-24 45 6.6 135-156 168-217 12-15 21-26 103-119 307-386 7-8 23-29 45 8.4 135-155 161-209 9-12 21-26 106-122 309-388 5-7 23-29 55 6.6 136-157 196-252 12-15 20-26 120-139 324-408 8-10 26-33 55 8.4 136-157 189-244 9-12 21-26 124-143 327-411 6-8 26-34 68 6.6 138-159 234-302 12-15 20-25 145-167 359-450 9-12 30-39 68 8.4 138-159 226-292 9-12 20-26 150-173 363-454 7-9 31-39 75 6.6 140-161 259-333 11-15 20-25 160-184 373-468 10-13 33-42 75 8.4 139-160 251-323 9-11 20-26 166-191 377-472 8-10 33-42 86 6.6 141-163 300-386 11-14 20-25 185-213 398-499 11-14 35-45 86 8.4 141-162 292-375 9-11 20-26 193-222 402-505 9-12 36-45 95 6.6 143-164 338-434 11-14 20-25 — — — — 95 8.4 143-164 329-423 9-11 20-26 — — — — 35 7.8 — — — — 86-99 281-353 6-7 22-27 Suction Discharge Water pressure pressure temp rise (psig) (psig) (ºF) Air temp drop (ºF DB) Suction Discharge Water Air temp pressure pressure Temp drop rise (psig) (psig) (ºF) (ºF DB) 35 9.8 — — — — 88-101 282-354 4-6 22-28 45 7.8 138-159 161-212 12-15 21-27 101-116 297-372 7-8 25-31 45 9.8 138-159 155-204 10-12 21-27 103-119 299-375 5-7 25-32 55 7.8 139-160 190-249 12-15 21-27 117-135 312-392 8-10 28-35 55 9.8 139-160 183-240 10-12 21-27 120-139 314-395 6-8 29-35 68 7.8 140-161 230-300 12-15 21-26 142-163 348-434 9-11 32-40 68 9.8 140-161 222-290 9-12 21-26 146-168 351-438 7-9 33-41 75 7.8 141-162 255-332 12-15 20-26 156-180 361-450 10-12 35-43 75 9.8 141-162 247-322 9-12 20-26 161-186 365-456 8-10 35-44 86 7.8 143-164 298-387 11-14 19-25 181-209 384-480 11-14 37-46 86 9.8 142-164 290-376 9-12 19-25 188-216 388-485 9-11 37-47 95 7.8 144-166 337-437 11-14 19-24 — — — — 95 9.8 144-165 329-426 9-11 19-24 — — — — 35 8.8 — — — — 88-101 287-362 6-7 20-25 35 11.2 — — — — 90-103 289-364 5-6 20-26 45 8.8 136-156 173-224 12-15 21-27 103-118 303-382 7-9 23-29 45 11.2 136-156 167-215 10-12 22-28 106-122 305-385 5-7 23-30 55 8.8 137-158 202-261 12-15 21-27 120-138 319-402 8-10 26-33 55 11.2 137-158 195-251 9-12 21-27 123-142 323-407 6-8 27-34 68 8.8 139-160 245-315 12-15 20-26 145-166 353-443 9-12 30-38 68 11.2 139-160 237-305 9-12 21-26 150-172 357-448 7-9 31-39 75 8.8 140-161 270-347 12-15 20-25 159-183 367-461 10-13 32-40 75 11.2 140-161 262-337 9-12 20-26 165-190 371-466 8-10 32-41 86 8.8 142-163 312-401 11-14 19-25 185-213 392-492 11-14 33-42 86 11.2 142-163 303-390 9-11 19-25 192-221 398-500 9-12 34-43 95 8.8 144-165 351-451 11-14 19-24 — — — — 95 11.2 143-165 342-440 9-11 19-24 — — — — WSHP-SVX01N-EN Start-Up Table 55. Operating pressures in cooling/heating for EX* units (continued) Operating Data Cooling Model EXH*060 (60 Hz) EXH*070 (60 Hz) EXV*006 (60 Hz) Heating Entering water temp (ºF) Water flow (GPM) 35 11.6 — — — — 88-102 314-395 6-7 21-27 35 14.0 — — — — 90-103 315-397 5-6 21-27 45 11.6 130-150 171-221 12-15 21-27 103-119 340-426 7-8 24-31 45 14.0 130-150 166-214 10-13 21-26 106-122 341-428 6-7 24-31 55 11.6 132-152 199-256 12-15 20-26 121-139 360-452 8-10 27-35 55 14.0 132-151 193-249 10-12 21-26 123-142 364-457 6-8 28-35 68 11.6 134-154 237-306 11-15 20-26 146-168 398-499 9-12 31-40 68 14.0 134-154 231-298 9-12 20-26 150-172 402-503 8-10 32-40 75 11.6 135-155 262-337 11-14 20-25 161-185 416-521 10-12 33-42 75 14.0 135-155 256-330 9-12 20-26 165-190 421-528 8-11 34-43 86 11.6 137-157 304-391 11-14 20-25 186-214 449-564 11-14 36-45 86 14.0 137-157 298-383 9-12 20-25 192-221 454-570 9-12 36-46 95 11.6 138-159 342-440 11-14 19-24 — — — — 95 14.0 138-159 335-431 9-11 19-25 — — — — 35 12.3 — — — — 85-98 296-373 6-7 20-25 35 15.4 — — — — 87-100 298-375 5-6 20-26 45 12.3 132-151 167-216 12-16 22-28 100-115 322-403 7-8 23-29 45 15.4 132-151 161-209 10-12 22-28 103-118 324-406 5-7 23-30 55 12.3 132-152 195-252 12-15 21-27 117-134 341-427 8-10 26-33 55 15.4 132-152 188-244 10-12 21-27 120-138 343-431 6-8 26-34 68 12.3 134-154 235-304 12-15 21-27 141-162 374-468 9-12 30-39 68 15.4 134-154 228-294 10-12 21-27 145-167 378-473 8-10 31-39 75 12.3 135-155 259-335 12-15 21-26 155-179 390-488 10-13 33-42 75 15.4 135-155 252-325 9-12 21-26 160-185 395-494 8-10 34-43 86 12.3 136-157 297-384 12-15 20-26 180-207 418-524 11-15 37-47 86 15.4 136-157 289-374 9-12 20-26 186-215 423-530 9-12 38-48 95 12.3 138-159 334-431 11-15 20-25 — — — — 95 15.4 138-159 326-421 9-12 20-25 — — — — 35 1.4 — — — — 94-108 279-355 6-8 23-29 35 1.7 — — — — 96-110 281-357 5-6 23-29 45 1.4 143-165 190-243 13-16 24-30 110-127 297-377 7-9 26-34 45 1.7 143-164 184-235 11-13 24-31 113-130 300-382 6-8 27-34 55 1.4 145-167 217-277 13-16 23-30 128-147 317-404 8-10 30-39 55 1.7 144-166 210-268 11-13 24-30 131-151 320-407 7-9 31-39 68 1.4 148-171 254-324 12-15 23-29 154-177 345-439 10-12 35-45 68 1.7 147-170 244-312 10-13 23-29 158-182 349-444 8-10 36-45 75 1.4 148-171 281-358 12-15 23-29 169-195 361-459 10-13 38-48 75 1.7 148-170 273-348 10-13 23-29 175-201 366-466 9-11 38-48 86 1.4 149-172 328-418 12-15 22-28 197-226 388-494 11-15 41-52 86 1.7 149-172 320-407 10-13 23-29 203-234 395-502 10-12 41-52 95 1.4 151-173 373-474 12-15 22-28 — — — — 95 1.7 150-173 363-462 10-13 22-28 — — — — WSHP-SVX01N-EN Suction Discharge Water pressure pressure temp rise (psig) (psig) (ºF) Air temp drop (ºF DB) Suction Discharge Water Air temp pressure pressure Temp drop rise (psig) (psig) (ºF) (ºF DB) 111 Start-Up Table 55. Operating pressures in cooling/heating for EX* units (continued) Operating Data Cooling Model EXV*009 (60 Hz) EXV*012 60 Hz) EXV*015 (60 Hz) 112 Heating Entering water temp (ºF) Water flow (GPM) 35 1.7 — — — — 93-107 272-346 6-7 20-26 35 2.1 — — — — 95-110 274-348 5-6 21-27 45 1.7 142-164 187-238 13-16 22-28 109-126 288-366 7-9 24-30 45 2.1 142-164 181-230 11-14 22-27 112-129 291-370 6-7 24-31 55 1.7 144-166 214-272 12-15 21-27 127-146 305-388 8-10 27-34 55 2.1 144-166 207-263 10-13 21-27 130-150 309-393 7-8 27-35 68 1.7 146-168 258-328 12-15 20-26 153-176 330-420 9-12 31-39 68 2.1 146-168 250-318 10-12 21-26 157-181 335-427 8-10 32-40 75 1.7 147-169 286-363 12-15 20-25 168-193 345-439 10-13 33-42 75 2.1 147-169 277-352 9-12 20-26 174-200 350-446 8-11 34-43 86 1.7 149-171 336-427 12-15 19-25 195-224 370-471 11-14 36-46 86 2.1 148-171 326-415 9-12 20-25 202-232 375-477 9-12 37-47 95 1.7 149-172 386-491 12-15 19-24 — — — — 95 2.1 149-172 375-477 9-12 19-24 — — — — 35 2.2 — — — — 92-106 288-367 10-13 21-27 35 2.8 — — — — 95-109 290-370 8-11 21-27 45 2.2 142-163 183-233 12-15 22-28 108-125 304-387 12-15 24-30 45 2.8 142-163 175-223 9-12 23-29 111-128 307-391 9-12 24-31 55 2.2 143-164 212-270 12-15 21-27 126-145 322-410 13-16 26-33 55 2.8 143-164 204-260 9-12 22-27 130-149 325-413 10-13 27-34 68 2.2 144-166 257-327 12-15 21-26 152-174 346-441 14-18 29-37 68 2.8 144-166 248-316 9-12 21-26 157-180 352-448 11-15 29-37 75 2.2 145-167 284-361 12-15 20-26 167-192 361-460 15-19 30-38 75 2.8 145-167 274-349 9-12 20-26 173-199 366-466 12-15 30-39 86 2.2 146-168 332-422 12-15 19-25 194-223 384-489 16-21 32-40 86 2.8 146-168 321-409 9-12 20-25 201-231 390-497 13-17 32-41 95 2.2 147-170 376-478 12-15 19-24 — — — — 95 2.8 147-170 365-465 9-12 19-24 — — — — 35 2.8 — — — — 91-105 296-377 6-7 20-25 35 3.5 — — — — 93-107 299-380 5-6 20-26 45 2.8 138-159 180-230 11-14 22-28 107-123 313-398 7-8 23-29 45 3.5 138-158 174-221 9-11 22-27 109-126 316-402 5-7 23-30 55 2.8 139-159 210-267 11-14 21-27 124-143 332-423 8-10 26-33 55 3.5 138-159 203-258 9-11 21-27 128-147 336-427 6-8 27-34 68 2.8 140-161 254-324 11-14 20-26 150-172 358-456 9-11 30-38 68 3.5 140-161 246-313 9-11 21-26 154-178 364-463 7-9 30-39 75 2.8 141-162 281-358 11-14 20-25 165-190 373-475 10-12 32-40 75 3.5 140-162 272-347 9-11 20-26 171-196 379-483 8-10 32-41 86 2.8 142-163 328-417 11-14 19-25 191-220 399-508 11-14 34-43 86 3.5 142-163 318-405 9-11 20-25 198-228 405-515 9-11 34-44 95 2.8 143-165 371-472 11-14 19-24 — — — — 95 3.5 143-165 361-459 9-11 19-24 — — — — Suction Discharge Water pressure pressure temp rise (psig) (psig) (ºF) Air temp drop (ºF DB) Suction Discharge Water Air temp pressure pressure Temp drop rise (psig) (psig) (ºF) (ºF DB) WSHP-SVX01N-EN Start-Up Table 55. Operating pressures in cooling/heating for EX* units (continued) Operating Data Cooling Model EXV*018 (60 Hz) EXV*024 (60 Hz) EXV*030 (60 Hz) Heating Entering water temp (ºF) Water flow (GPM) 35 3.3 — — — — 91-104 280-353 6-8 21-26 35 4.2 — — — — 92-106 281-355 5-6 21-27 45 3.3 142-163 158-206 11-15 23-29 106-122 301-379 7-9 24-30 45 4.2 141-163 151-197 9-11 23-29 108-125 304-383 6-7 24-31 55 3.3 141-162 187-243 12-15 23-29 123-142 319-401 8-10 27-34 55 4.2 141-162 179-233 9-12 23-29 126-145 322-405 6-8 27-35 68 3.3 141-163 227-295 12-15 22-28 149-171 352-441 10-12 31-39 68 4.2 141-163 219-284 9-12 22-28 153-176 356-446 8-10 32-40 75 3.3 142-163 253-328 12-15 21-27 165-189 364-456 10-13 33-42 75 4.2 142-163 245-317 9-12 21-27 170-196 368-461 8-10 34-43 86 3.3 143-165 298-385 12-15 20-26 192-221 383-480 11-14 36-46 86 4.2 143-164 288-372 9-12 20-26 199-229 386-484 9-11 37-47 95 3.3 144-166 339-437 12-15 19-24 — — — — 95 4.2 144-166 329-424 9-12 19-25 — — — — 35 4.4 — — — — 85-98 278-351 6-7 21-27 35 5.6 — — — — 87-100 280-353 4-6 22-28 45 4.4 136-156 165-215 12-15 23-30 100-115 299-375 7-8 25-32 45 5.6 135-156 158-206 10-12 23-30 103-118 301-378 5-7 26-32 55 4.4 137-158 193-251 12-15 22-28 117-134 314-395 8-10 29-36 55 5.6 137-157 186-241 9-12 22-29 120-138 318-399 6-8 29-37 68 4.4 138-159 234-304 12-15 21-27 141-162 346-433 9-11 33-42 68 5.6 138-159 226-293 9-12 22-28 145-167 350-438 7-9 33-42 75 4.4 139-160 260-336 12-15 21-27 155-179 358-449 10-12 35-44 75 5.6 139-160 251-325 9-12 21-27 161-185 363-454 8-10 35-45 86 4.4 141-162 303-391 12-15 20-26 180-207 380-476 11-14 37-47 86 5.6 141-162 294-379 9-12 20-26 187-215 385-482 9-11 38-48 95 4.4 142-164 343-442 11-15 19-25 — — — — 95 5.6 142-163 334-430 9-11 20-25 — — — — 35 5.5 — — — — 87-101 266-337 6-7 20-25 35 7.0 — — — — 89-103 267-340 4-6 20-26 45 5.5 137-158 164-214 12-15 22-28 102-118 284-359 7-8 23-29 45 7.0 137-157 158-206 9-12 22-27 105-121 286-362 5-7 23-30 55 5.5 138-159 192-250 12-15 21-27 119-137 299-379 8-10 26-33 55 7.0 138-159 185-241 9-12 21-27 122-141 302-382 6-8 27-34 68 5.5 140-161 231-301 11-15 20-26 143-165 328-413 9-12 30-38 68 7.0 140-161 223-291 9-11 21-26 148-170 332-419 7-9 30-39 75 5.5 141-162 257-334 11-14 20-25 158-182 341-430 10-13 32-40 75 7.0 141-162 249-323 9-11 20-26 164-188 346-436 8-10 32-41 86 5.5 143-164 300-388 11-14 19-25 183-211 364-460 11-14 34-43 86 7.0 142-164 291-377 9-11 20-25 190-219 368-465 9-11 34-44 95 5.5 144-165 340-440 11-14 19-24 — — — — 95 7.0 144-165 331-428 9-11 19-24 — — — — WSHP-SVX01N-EN Suction Discharge Water pressure pressure temp rise (psig) (psig) (ºF) Air temp drop (ºF DB) Suction Discharge Water Air temp pressure pressure Temp drop rise (psig) (psig) (ºF) (ºF DB) 113 Start-Up Table 55. Operating pressures in cooling/heating for EX* units (continued) Operating Data Cooling Model EXV*036 (60 Hz) EXV*042 (60 Hz) EXV*048 (60 Hz) 114 Heating Entering water temp (ºF) Water flow (GPM) 35 6.6 — — — — 88-101 292-368 6-7 19-24 35 8.4 — — — — 89-103 293-369 5-6 19-24 45 6.6 133-153 169-218 12-15 20-26 103-118 310-390 7-8 23-29 45 8.4 132-152 162-210 9-12 21-26 105-121 311-392 5-7 23-29 55 6.6 134-154 197-254 12-15 20-26 119-137 327-412 8-10 26-33 55 8.4 134-154 190-245 9-12 20-26 122-141 330-415 6-8 26-34 68 6.6 136-156 236-304 12-15 20-25 144-166 362-454 9-12 30-39 68 8.4 136-156 228-295 9-12 20-25 148-171 365-457 7-9 31-39 75 6.6 137-158 261-336 11-14 20-25 159-183 378-474 10-13 33-42 75 8.4 137-158 253-326 9-11 20-25 164-189 382-479 8-10 33-42 86 6.6 139-160 303-390 11-14 19-24 184-212 403-506 11-15 35-45 86 8.4 139-160 295-379 9-11 19-24 191-219 409-514 9-12 36-45 95 6.6 141-162 342-439 11-14 19-24 — — — — 95 8.4 141-162 333-428 9-11 19-24 — — — — 35 7.8 — — — — 84-97 285-358 5-7 19-24 35 9.8 — — — — 86-99 286-359 4-6 19-25 45 7.8 134-155 160-210 12-15 21-27 99-114 300-377 6-8 22-28 45 9.8 134-154 153-202 10-12 21-27 101-116 302-379 5-7 22-29 55 7.8 135-156 189-247 12-15 21-27 115-132 315-396 7-9 25-32 55 9.8 135-156 182-238 9-12 21-27 118-136 319-400 6-8 26-32 68 7.8 137-158 229-299 12-15 21-26 139-160 352-438 9-11 29-37 68 9.8 137-158 221-289 9-12 21-26 143-165 354-442 7-9 30-38 75 7.8 138-159 255-332 12-15 20-26 154-177 365-456 10-12 32-40 75 9.8 138-159 247-322 9-12 20-26 158-182 369-460 8-10 32-41 86 7.8 140-161 299-389 11-15 19-25 179-205 388-485 11-14 34-43 86 9.8 140-161 291-379 9-12 19-25 184-212 392-490 9-11 34-44 95 7.8 142-163 341-442 11-14 19-24 — — — — 95 9.8 142-163 332-430 9-11 19-24 — — — — 35 8.8 — — — — 87-101 285-359 6-7 20-25 35 11.2 — — — — 90-103 287-362 5-6 20-26 45 8.8 135-156 172-222 12-15 21-27 103-118 300-378 7-8 23-29 45 11.2 135-155 165-214 9-12 22-28 105-121 303-382 5-7 23-30 55 8.8 136-157 201-259 12-15 21-27 120-138 316-398 8-10 26-33 55 11.2 136-157 193-249 9-12 21-27 123-142 320-403 6-8 27-34 68 8.8 138-159 243-313 12-15 20-26 144-166 348-437 9-12 30-38 68 11.2 138-159 235-303 9-12 21-26 149-171 352-442 7-9 31-39 75 8.8 139-160 269-345 11-15 20-25 159-183 363-455 10-13 32-40 75 11.2 139-160 260-334 9-11 20-26 165-189 367-461 8-10 32-41 86 8.8 141-162 310-399 11-14 19-25 184-212 386-485 11-14 33-42 86 11.2 141-162 301-387 9-11 19-25 191-220 392-493 9-12 34-43 95 8.8 143-164 349-448 11-14 19-24 — — — — 95 11.2 143-164 340-437 9-11 19-24 — — — — Suction Discharge Water pressure pressure temp rise (psig) (psig) (ºF) Air temp drop (ºF DB) Suction Discharge Water Air temp pressure pressure Temp drop rise (psig) (psig) (ºF) (ºF DB) WSHP-SVX01N-EN Start-Up Table 55. Operating pressures in cooling/heating for EX* units (continued) Operating Data Cooling Model EXV*060 (60 Hz) EXV*070 (60 Hz) Heating Entering water temp (ºF) Water flow (GPM) 35 11.6 — — — — 89-102 300-377 6-7 21-27 35 14.0 — — — — 90-104 301-379 5-6 21-27 45 11.6 132-152 169-219 12-15 21-27 104-120 324-406 7-9 24-31 45 14.0 132-152 164-212 10-13 21-26 106-122 325-407 6-7 24-31 55 11.6 133-153 197-254 12-15 20-26 121-139 343-430 8-10 27-35 55 14.0 133-153 192-247 10-12 21-26 124-142 344-432 7-8 28-35 68 11.6 135-156 235-303 12-15 20-26 146-168 377-472 9-12 31-40 68 14.0 135-156 229-296 10-12 20-26 150-172 380-476 8-10 32-40 75 11.6 136-157 260-335 11-14 20-25 161-185 394-493 10-13 33-42 75 14.0 136-157 253-326 9-12 20-26 165-190 398-499 9-11 34-43 86 11.6 138-159 302-388 11-14 20-25 186-214 424-532 12-15 36-45 86 14.0 138-159 295-379 9-12 20-25 192-221 429-538 10-12 36-46 95 11.6 140-161 339-436 11-14 19-24 — — — — 95 14.0 140-161 332-427 9-12 19-25 — — — — 35 12.32 — — — — 86-100 294-371 6-7 20-26 Suction Discharge Water pressure pressure temp rise (psig) (psig) (ºF) Air temp drop (ºF DB) Suction Discharge Water Air temp pressure pressure Temp drop rise (psig) (psig) (ºF) (ºF DB) 35 15.4 — — — — 88-102 296-373 5-6 21-26 45 12.32 131-150 166-216 12-15 21-27 101-117 320-401 7-9 23-29 45 15.4 131-150 160-208 10-12 21-27 104-119 322-404 6-7 24-30 55 12.32 131-151 194-252 12-15 21-27 118-136 338-424 8-10 26-33 55 15.4 131-151 188-243 10-12 21-27 121-139 340-427 6-8 27-34 68 12.32 133-153 235-303 12-15 20-26 142-164 374-467 9-12 31-39 68 15.4 133-153 228-294 9-12 21-26 146-168 376-470 8-10 31-40 75 12.32 134-154 259-335 12-15 20-26 157-180 389-487 10-13 33-42 75 15.4 134-154 252-325 9-12 20-26 162-186 393-492 8-11 34-43 86 12.32 136-156 297-384 11-15 20-25 181-209 417-523 12-15 37-47 86 15.4 136-156 289-374 9-12 20-25 188-216 422-529 9-12 38-48 95 12.32 137-158 335-432 11-14 19-25 — — — — 95 15.4 137-158 327-422 9-12 19-25 — — — — Water Pressure Drop Table 56. Cooling water pressure drops (WPD) in feet of head for GE* units - ½- 6 ton (continued) Table 56, p. 115 should be used to define feet of head/ pressure drop. Please note the feet of pressure (ft/head) provided is at ARI/ISO standard. Unit Size (60 Hz) Unit Size (50 Hz) EWT °F GPM Ft. Pressure To calculate feet of head, when using gauges that read in PSIG, multiply PSI by 2.31. GEH024 GEH018 86 5.6 13.2 GEH030 GEH024 86 7.0 11.1 GEH036 GEH030 86 8.4 11.5 GEH042 GEH036 86 9.8 13.6 Table 56. Cooling water pressure drops (WPD) in feet of head for GE* units - ½- 6 ton GEH048 GEH042 86 11.2 6.8 GEH060 GEH048 86 14.0 12.3 GPM Ft. Pressure — GEH060 86 14.0 11.4 1.8 3.9 GEH072 — 86 18.0 12.0 86 2.1 3.7 GEH090 GEH072 86 22.5 13.8 GEH009 86 2.8 3.8 GEH120 GEH090 86 30.0 14.1 GEH015 GEH012 86 3.5 5.4 GEH150 GEH120 86 37.5 13.4 GEH018 GEH015 86 4.2 6.8 GEH180 GEH150 86 45.0 18.2 Unit Size (60 Hz) Unit Size (50 Hz) EWT °F GEH006 — 86 GEH009 GEH006 GEH012 WSHP-SVX01N-EN 115 Start-Up Table 56. Unit Size (60 Hz) Cooling water pressure drops (WPD) in feet of head for GE* units - ½- 6 ton (continued) Table 57. Cooling water pressure drops (WPD) in feet of head for EX* units (continued) Unit Size (50 Hz) EWT °F GPM Ft. Pressure Unit Size (60 Hz) Unit Size (50 Hz) EWT °F GPM Ft. Pressure GEV006 — 86 1.8 3.0 EXV060 — 86 14 7.4 GEV009 GEV006 86 2.1 3.9 EXV070 — 86 15.4 6.6 GEV012 GEV009 86 2.8 3.8 GEV015 GEV012 86 3.5 5.3 GEV018 GEV015 86 4.2 6.3 GEV024 GEV018 86 5.6 12.9 GEV030 GEV024 86 7.0 12.2 GEV036 GEV030 86 8.4 12.5 GEV042 GEV036 86 9.8 14.5 GEV048 GEV042 86 11.2 5.7 GEV060 GEV048 86 14.0 12.0 — GEV060 86 14.0 10.8 GEV072 — 86 18.0 12.0 GEV090 GEV072 86 22.5 13.4 GEV120 GEV090 86 30.0 14.1 GEV150 GEV120 86 37.5 13.4 GEV180 GEV150 86 45.0 18.2 GEV240 GEV300 Table 57. Unit Size (60 Hz) EXH006 EXH009 GEV180 GEV240 86 86 60.0 75.0 14.0 13.2 — — EWT °F 86 86 GPM 1.8 2.1 Unit Size (60 Hz) Heating water pressure drops (WPD) in feet of head for GE* units Unit Size (50 Hz) EWT °F GPM Ft. Pressure GEH006 — 68 1.8 4.2 GEH009 GEH006 68 2.1 3.9 GEH012 GEH009 68 2.8 4.1 GEH015 GEH012 68 3.5 5.7 GEH018 GEH015 68 4.2 7.2 GEH024 GEH018 68 5.6 14 GEH030 GEH024 68 7.0 11.8 GEH036 GEH030 68 8.4 12.1 GEH042 GEH036 68 9.8 14.5 GEH048 GEH042 68 11.2 7.2 GEH060 GEH048 68 14.0 13.1 — GEH060 68 14.0 12.1 GEH072 — 68 18.0 13.9 GEH090 GEH072 68 22.5 15.7 GEH120 GEH090 68 30.0 16.0 GEH150 GEH120 68 37.5 14.8 3.9 GEH180 GEH150 68 45.0 20.3 3.7 GEV006 — 68 1.8 3.2 GEV006 68 2.1 4.2 Cooling water pressure drops (WPD) in feet of head for EX* units Unit Size (50 Hz) Table 58. Ft. Pressure EXH012 — 86 2.8 3.8 GEV009 EXH015 — 86 3.5 5.4 GEV012 GEV009 68 2.8 4.1 4.1 GEV015 GEV012 68 3.5 5.6 6.1 GEV018 GEV015 68 4.2 6.7 GEV018 68 5.6 13.7 EXH018 EXH024 — — 86 86 4.2 5.6 EXH030 — 86 7 9.2 GEV024 EXH036 — 86 8.4 5.5 GEV030 GEV024 68 7.0 12.9 GEV030 68 8.4 13.2 EXH042 — 86 9.8 7.8 GEV036 EXH048 — 86 11.2 8.2 GEV042 GEV036 68 9.8 15.4 GEV042 68 11.2 6.1 12.7 EXH060 — 86 14 7.2 GEV048 EXH070 — 86 15.4 6.3 GEV060 GEV048 68 14.0 3.0 — GEV060 68 14.0 11.5 — 68 18.0 13.9 EXV006 — 86 1.8 EXV009 — 86 2.1 3.9 GEV072 EXV012 — 86 2.8 3.8 GEV090 GEV072 68 22.5 15.3 EXV015 — 86 3.5 5.3 GEV120 GEV090 68 30.0 16.0 3.7 GEV150 GEV120 68 37.5 14.8 6.5 GEV180 GEV150 68 45.0 20.3 GEV180 68 60.0 16.0 GEV240 68 75.0 14.8 EXV018 EXV024 — — 86 86 4.2 5.6 EXV030 — 86 7 8.5 GEV240 EXV036 — 86 8.4 6.3 GEV300 EXV042 — 86 9.8 8.5 EXV048 — 86 11.2 7.9 116 WSHP-SVX01N-EN Start-Up Table 59. Heating water pressure drops (WPD) in feet of head for EX* units Unit Size (60 Hz) Unit Size (50 Hz) EWT °F GPM Ft. Pressure EXH006 — 68 1.8 4.2 EXH009 — 68 2.1 3.9 EXH012 — 68 2.8 4.1 EXH015 — 68 3.5 5.7 EXH018 — 68 4.2 5.0 EXH024 — 68 5.6 7.9 EXH030 — 68 7.0 11.2 EXH036 — 68 8.4 6.5 EXH042 — 68 9.8 9.4 EXH048 — 68 11.2 9.4 EXH060 — 68 14.0 7.1 EXH070 — 68 15.4 7.2 EXV006 — 68 1.8 4.2 EXV009 — 68 2.1 3.9 EXV012 — 68 2.8 4.1 EXV015 — 68 3.5 5.7 EXV018 — 68 4.2 4.5 EXV024 — 68 5.6 8.2 EXV030 — 68 7.0 10.2 EXV036 — 68 8.4 7.5 EXV042 — 68 9.8 9.8 EXV048 — 68 11.2 9.1 EXV060 — 68 14.0 7.2 EXV070 — 68 15.4 7.6 Water Volume Table 60, p. 117 is provided for use in calculating glycol requirements for the unit. Table 60. Water volume for GE* units Water Side Water Side Water Side Volume Volume Volume (ft3) (gallons) (in3) Unit Size (60 Hz) Unit Size (50 Hz) 006 — 13.6 0.008 0.059 009 006 13.6 0.008 0.059 012 009 28.2 0.016 0.122 015 012 36.0 0.021 0.156 018 015 28.2 0.016 0.122 024 018 37.8 0.022 0.164 030 024 49.1 0.028 0.213 036 030 70.4 0.041 0.305 042 036 79.0 0.046 0.342 048 042 71.7 0.041 0.310 060 048 91.8 0.053 0.397 — 060 91.8 0.053 0.397 072 — 181 0.105 0.783 WSHP-SVX01N-EN Table 60. Water volume for GE* units (continued) Water Side Water Side Water Side Volume Volume Volume (ft3) (gallons) (in3) Unit Size (60 Hz) Unit Size (50 Hz) 090 072 214 0.125 0.927 120 090 390 0.227 1.690 150, 180 120, 150 508 0.296 2.201 240 180 779 0.453 3.374 300 240 1057 0.615 4.576 Table 61. Water volume for EX* units Water Side Water Side Water Side Volume Volume Volume (ft3) (gallons) (in3) Unit Size (60 Hz) Unit Size (50 Hz) EXH006 — 13.6 0.008 0.059 EXH009 — 13.6 0.008 0.059 EXH012 — 28.4 0.016 0.123 EXH015 — 36.0 0.021 0.156 EXH018 — 89.8 0.052 0.389 EXH024 — 89.8 0.052 0.389 EXH030 — 89.8 0.052 0.389 EXH036 — 171.2 0.099 0.741 EXH042 — 200.8 0.116 0.869 EXH048 — 200.8 0.116 0.869 EXH060 — 331.2 0.192 1.434 EXH070 — 331.2 0.192 1.434 EXV006 — 13.6 0.008 0.059 EXV009 — 13.6 0.008 0.059 EXV012 — 28.4 0.016 0.123 EXV015 — 36.0 0.021 0.156 EXV018 — 89.8 0.052 0.389 EXV024 — 89.8 0.052 0.389 EXV030 — 89.8 0.052 0.389 EXV036 — 171.2 0.099 0.741 EXV042 — 200.8 0.116 0.869 EXV048 — 200.8 0.116 0.869 EXV060 — 331.2 0.192 1.434 EXV070 — 331.2 0.192 1.434 117 Maintenance WARNING Hazardous Service Procedures! The maintenance and trouble shooting procedures recommended in this section of the manual could result in exposure to electrical, mechanical or other potential safety hazards. Always refer to the safety warnings provided throughout this manual concerning these procedures. When possible, disconnect all electrical power including remote disconnects before servicing. Follow proper lockout/tagout procedures to ensure the power can not be inadvertently energized. When necessary to work with live electrical components, have a qualified licensed electrician or other individual who has been trained in handling live electrical components per these tasks. Failure to follow all of the recommended safety warnings provided, could result in death or serious injury. Preventive Maintenance Maintenance on the unit is simplified with the following preventive suggestions: Filter maintenance must be performed to assure proper operation of the equipment. Filters should be inspected at least every three months, and replaced when it is evident they are dirty. Filter sizing is shown in Table 62, p. 118: Table 62. Filter sizing Size (60 Hz) Filter Size (Actual) inches (mm) Size (50 Hz) GEH 006-015 006-012 14 5/8 x 20 1/4 (371 x 514) A strainer (60 mesh or greater) must be used on an open loop system to keep debris from entering the unit heat exchanger and to ensure a clean system. For units on well water, it is important to check the cleanliness of the water-to-refrigerant heat exchanger. Should it become contaminated with dirt and scaling as a result of bad water, the heat exchanger will have to be back flushed and cleaned with a chemical that will remove the scale.This service should be performed by an experienced service person. WARNING Hazardous Chemicals! Cleaning agents can be either acidic or highly alkaline. Handle chemical carefully. Proper handling should include goggles or face shield, chemical resistant gloves, boots, apron or suit as required. For personal safety, refer to the cleaning agent manufacturers Materials Safety Data Sheet and follow all recommended safe handling practices. Failure to follow all safety instructions could result in death or serious injury. It should be noted that the water quality should be checked periodically. See Table 63, p. 118. Table 63. Water quality Scaling Amount Less than 350 ppm 018-030 015-024 17 7/8 x 23 7/8 (454 x 607) Calcium and magnesium (total hardness) 036-042 030-036 18 5/8 x 25 3/8 (473 x 645) Corrosion 048-060 042-060 20 5/8 x 29 3/4 (524 x 755) pH 7-9.5 072-120 072-090 20 x 25 (3) (508 x 508) Hydrogen Sulfide Less than 1 ppm 150-180 120-150 25 x 25 (3) (635 x 635) GEV 006-015 006-012 15 7/8 x 19 7/8 (403 x 504) 018-030 015-024 19 7/8 x 19 7/8 (505 x 505) 036-042 030-036 19 7/8 x 24 7/8 (504 x 632) 048-060 042-060 23 7/8 x 29 7/8 (606 x 759) GEV 072-120 090 20 x 20 (4) (508 x 508) 150-300 120-240 19 5/8 x 24 5/8 (6) (498 x 625)‘ Sulfates Less than 25 ppm Chlorides Less than 125 ppm Carbon Dioxide Less than 75 ppm Total dissolved solids (TDS) Less than 1000 ppm Biological Growth Iron Bacteria 006-015 — 14 5/8 x 20 1/4 (371 x 514) 018-024 — 17 7/8 X 23 7/8 (454 X 607) 030-036 — 18 5/8 x 25 3/8 (473 x 645) 042-070 — 20 5/8 x 29 3/4 (524 x 755) 006-015 — 15 7/8 x 19 7/8 (403 x 504) 018-024 — 19 7/8 x 19 7/8 (505 x 505) 030-036 — 19 7/8 x 24 7/8 (504 x 632) 042-060 — 23 7/8 x 29 7/8 (606 x 759) 070 — 27 7/8 x 29 7/8 (708 x 759) EXV Low Erosion Suspended Solids EXH 118 Check the contactors and relays within the control panel at least once a year. It is good practice to check the tightness of the various wiring connections within the control panel. Low Condensate Trap For units incorporating a negative trap design, ensure that the condensate system is primed with water at all times. Allowing a negative, pressure condensate system to run dry could cause a break in the condensate seal allowing the fan to draw water from the condensate line to spray moisture into the mechanical system. By maintaining a primed condensate trap, a seal will be created and will help prevent these complications. WSHP-SVX01N-EN Troubleshooting Deluxe Controls WARNING Hazardous Service Procedures! The maintenance and trouble shooting procedures recommended in this section of the manual could result in exposure to electrical, mechanical or other potential safety hazards. Always refer to the safety warnings provided throughout this manual concerning these procedures. When possible, disconnect all electrical power including remote disconnects before servicing. Follow proper lockout/tagout procedures to ensure the power can not be inadvertently energized. When necessary to work with live electrical components, have a qualified licensed electrician or other individual who has been trained in handling live electrical components per these tasks. Failure to follow all of the recommended safety warnings provided, could result in death or serious injury. Table 64. Troubleshooting units which contain the deluxe control option may be made easy by using the three LEDs (light emitting diodes).These LEDs are provided for indicating the operating mode of the controller.The LEDs are intended to aid in troubleshooting.The LEDs are labeled on the circuit board with numbers as referenced in Table 64, p. 119. Diagnostic LEDs Color: Green LED1 Color: Red LED2 Controller Mode LED3 OFF OFF OFF Control OFF ON OFF OFF Normal/Compressor OFF ON OFF FLASH Anti-short cycle ON OFF ON Normal/Compressor ON FLASH ON OFF Brownout Condition ON FLASH ON Soft Lockout (low pressure) ON FLASH FLASH Soft Lockout (high pressure) ON ON ON Manual Lockout (low pressure) ON ON FLASH Manual Lockout (high pressure) ON FLASH OFF Manual Lockout (condensate overflow) ON ON OFF Compressor Disable Table 65. Troubleshooting table Problem No response to any thermostat setting Unit short cycles Blower runs, but compressor does not WSHP-SVX01N-EN Heating Cooling Cause Correction X X Main power off Check fuses X X Defective control transformer Replace X X Broken or loose connection Repair X X Defective thermostat Replace X X Transformer Reset Transformer X X Thermostat or sensor improperly located Relocate X X Defective compressor overload Replace (if external) X X Defective compressor contactor Replace X X Supply Voltage too low Correct X X Defective compressor capacitor Replace X X Defective windings Replace X X Limit switches open Check cause/Replace or repair 119 Troubleshooting Table 65. Troubleshooting table (continued) Problem Insufficient capacity Heating Cooling Cause Correction Dirty filter Replace/clean X Blower RPM too low Correct X Loss of conditioned air due to leaks in ductwork Repair leaks X X X X X X Low on refrigerant charge X X Restricted thermal expansion valve Replace X X Defective reversing valve See WSHP-IOM-# for touch test chart X X Thermostat improperly located Relocate X X Unit undersized Recalculate heat gains/losses X X Inadequate water flow Increase GPM X X Scaling in heat exchanger Clean or replace Water too hot Decrease temperature Water too cold Increase temperature X X Filter drier blocked Replace X X Defective reversing valve Check or replace X Inadequate GPM Increase water flow to unit X Water too hot Decrease temperature Inadequate air flow Check, clean blower and coil High pressure switch open X X Dirty filter Clean/replace X X Overcharged with refrigerant Decrease charge X X Defective pressure switch Check or replace X Trash in heat exchanger Backflush X Low water flow Increase GPM High head pressure X X Overcharge of refrigerant Decrease charge X X Non-condensable in system Evacuate and recharge by weight X X Water too hot Decrease temperature X Dirty filter Clean / replace X Inadequate air flow Check, clean blower and coil Locate leak, repair and recharge X X Undercharged X X Restricted thermal expansion valve Repair / replace X Inadequate air flow Check, clean blower and coil X 120 Locate leak, repair and recharge by weight (not by superheat) X X Low pressure switch open Correct Correct X X Low suction pressure Introduction of excessively hot return-air Introduction of excessively cold return-air Dirty filter Clean/replace X Inadequate GPM Increase GPM X Inadequate GPM Increase GPM X Water too cold Increase temperature X Inadequate air flow Increase CFM X Dirty filter Clean/replace Increase charge X X Undercharged with refrigerant X X Defective pressure switch Replace X X Heat transfer fluid too cold Raise water temperature WSHP-SVX01N-EN Wiring Diagrams This section contains wiring diagrams (Figure 81, p. 121– Figure 87, p. 127) and isolation valve wiring connections (Table 66, p. 121). Table 66. Control type Basic 24V Figure 81. Isolation valve wiring 3-wire Honeywell isolation valve connections Blue Brown Black 1TB1-6 1TB1-1 1TB1-4 Deluxe 24V 1TB1-6 1TB1-1 1TB1-4 ZN524 1TB1-18 1TB2-3 1TB1-16 GEH_V (½-5 tons) - basic-208V - 60 Hz - 1 ph(a) (a) Wiring diagrams provided in the catalog are generic. A unit specific As Built wiring diagram is located on the unit control panel. WSHP-SVX01N-EN 121 Wiring Diagrams Figure 82. GEH_V (½-5 tons) - basic 24V - 460V-60 Hz - 3 ph(a) (a) Wiring diagrams provided in the catalog are generic. A unit specific As Built wiring diagram is located on the unit control panel. 122 WSHP-SVX01N-EN Wiring Diagrams Figure 83. GEH_V (6-25 tons) - deluxe-380-420V - 50 Hz - 3 ph(a) 1U2 1U1 ISOLATED GENERAL ALARM CONTACTS. CONTACTS CLOSE WHEN CONTROL 1U1 AND 1U2 GOES INTO MANUAL LOCKOUT MODE. CONTACTS RATED FOR CLASS 2 24V. TERMINAL 1TB2-9 AND 10. VERIFY TEST JUMPER HAS BEEN REMOVED TO PREVENT CONTROL TIMING ERRORS. CONNECTION FOR 24VAC CLASS 2 COMPRESSOR DISABLE INPUT. TERMINAL 1TB2-7 AND 1TB2-8 CONNECT TERMINAL 11 TO 1TB2-1&2 AND TERMINAL 10 TO 1TB2-3&4 IF USING ZONE SENSOR X13790886010. (a) Wiring diagrams provided in the catalog are generic. A unit specific As Built wiring diagram is located on the unit control panel. WSHP-SVX01N-EN 123 Wiring Diagrams Figure 84. GEH_V (6-25 tons) - deluxe 24V - 460V-60 Hz - 3 ph(a) (a) Wiring diagrams provided in the catalog are generic. A unit specific As Built wiring diagram is located on the unit control panel. 124 WSHP-SVX01N-EN Wiring Diagrams Figure 85. EXH/EXV - deluxe 24V - 460V-60 Hz - 3 ph(a) - (ECM motor wiring diagram) (a) Wiring diagrams provided in the catalog are generic. A unit specific As Built wiring diagram is located on the unit control panel. WSHP-SVX01N-EN 125 Wiring Diagrams Figure 86. GEH_V (6-25 tons) - Tracer™ ZN524-460V - 60 Hz - 3 ph(a) (a) Wiring diagrams provided in the catalog are generic. A unit specific As Built wiring diagram is located on the unit control panel. 126 WSHP-SVX01N-EN Wiring Diagrams Figure 87. EXH_V - Tracer™ ZN524 460V-60 Hz - 3 ph(a) - (ECM motor wiring diagram) (a) Wiring diagrams provided in the catalog are generic. A unit specific As Built wiring diagram is located on the unit control panel. WSHP-SVX01N-EN 127 Wiring Diagrams Figure 88. GEH_V (½-5) tons - UC400(a) (a) Wiring diagrams provided in the catalog are generic. A unit specific As Built wiring diagram is located on the unit control panel. 128 WSHP-SVX01N-EN Wiring Diagrams Figure 89. GEH_V (6-25 tons) - UC400(a) (a) Wiring diagrams provided in the catalog are generic. A unit specific As Built wiring diagram is located on the unit control panel. WSHP-SVX01N-EN 129 Wiring Diagrams 130 WSHP-SVX01N-EN Warranty Information Standard Warranty Extended Warranty The standard water-source heat pump warranty isTrane’s parts-only warranty, running 12 months from startup, not to exceed 18-months from shipment. The optional extended warranty is a second through fifth year warranty.The time starts at the end of the standard 1 year coverage through the fifth year. These extended warranties apply only to new equipment installed in domesticTrane Commercial Systems Group sales territories and must be ordered prior to start-up. 131 WSHP-SVX01N-EN Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. © 2014Trane All rights reserved WSHP-SVX01N-EN 12 Sep 2014 We are committed to using environmentally Supersedes WSHP-SVX01M-EN (15 Dec 2013) conscious print practices that reduce waste.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Copyright : ? 2014 Trane Job Ref : Title 24 Producer : Acrobat Distiller 10.1.10 (Windows) Keywords : Axiom Horizontal/Vertical Water-Source Heat Pump, GEH, GEV, WSHP-SVX01N-EN September 2014 Modify Date : 2014:09:12 10:21:51-05:00 Creator Tool : FrameMaker 10.0.2 Create Date : 2014:09:12 09:08:39Z Metadata Date : 2014:09:12 10:21:51-05:00 Format : application/pdf Title : Axiom Horizontal/Vertical Water-Source Comfort System Models GEH and GEV; WSHP-SVX01N-EN September 2014 Creator : Unitary Technical Literature Description : Axiom Horizontal/Vertical Water-Source Comfort System Models GEH and GEV, 1/2-25 Tons (R-410A); WSHP-SVX01N-EN September 2014 Document ID : uuid:14a5651b-b678-4248-bbbf-21b6bf4435ff Instance ID : uuid:736d9a6a-ffa8-4493-a3d0-3091372c0695 Page Layout : OneColumn Page Mode : UseOutlines Page Count : 132 Author : Unitary Technical Literature Subject : Axiom Horizontal/Vertical Water-Source Comfort System Models GEH and GEV, 1/2-25 Tons (R-410A); WSHP-SVX01N-EN September 2014EXIF Metadata provided by EXIF.tools