Trane Performance Air Handlers Catalogue
2015-04-02
: Trane Trane-Performance-Air-Handlers-Catalogue-684265 trane-performance-air-handlers-catalogue-684265 trane pdf
Open the PDF directly: View PDF .
Page Count: 216
Download | |
Open PDF In Browser | View PDF |
Catalog Performance Climate Changer™ Air Handlers Sizes 3-120 Indoor and Outdoor Units Application and Performance Information September 2013 CLCH-PRC022A-EN Introduction Performance Climate Changer air handlers combine the Trane tradition of engineering excellence with the latest in manufacturing technology to give you an energy efficient air handler with superior performance, the highest quality and reliability, and the lowest installed cost in the industry. This air handler was designed to incorporate such features as component flexibility, integrated control options, and proven performance to give you the optimal system to clean, filter, dehumidify, heat, and cool your building. Superior Performance • ASHRAE 111 Class 6 low-leak casing design achieving less than 1.0 percent leakage rate at +/- 8 inches w.g. • Less than L/240 @ +/- 8 inches w.g. panel and door deflection • 2-inch R13 foam-insulated, mid-span thermal break panels and thermal break doors • Casing thermal resistance ratio TR-value of 0.6 • New filter technology that exceeds LEED requirements and reduces filter pressure drops up to 50 percent versus previous designs Industry-Leading Energy Efficiency • AMCA 611-certified Traq airflow monitoring station • Total energy-recovery wheels • Cool Dry Quiet (CDQ™) desiccant dehumidification wheels • Discharge plenums and plenum fan sections available with variable size, type, and location of openings to reduce static pressure loss and lower energy consumption • 50,000 hour LED service lights • Low-leak, high thermal performance casing design • All airfoil-bladed dampers and Traq dampers meet ASHRAE 90.1 lowest specified leakage requirements • High-efficiency coil fins deliver superior heat transfer while allowing face velocities in excess of 625 fpm without moisture carryover System Optimization • Optimal design to meet the Trane EarthWise™ design philosophy incorporating high-efficiency air handlers and water chillers with low flow rates and low temperatures. • Factory-engineered, -mounted, and -tested control packages with properly sealed casing openings. • Variety of coil types with high-efficiency coil fins allow lower coil approach temperature and reduce chance of moisture carryover • Ability to choose the exact number of fins per foot of coil surface to enhance heat transfer and air pressure performance • Wide array of fan options, including direct-drive plenum fans, belt-drive plenum fans, and housed fans • Control options to easily incorporate fan pressurization and demand control ventilation strategies. • Design and analysis tools provide whole building analysis, acoustical design guidance, equipment performance data, and suggested control strategies to help achieve optimum system design with tailored energy, IAQ, and project budget solutions. © 2013 Trane All rights reserved CLCH-PRC022A-EN Introduction Highest Quality • UL/CUL listed • AHRI Standard 430-certified air-handling unit • AHRI Standard 410-certified coils are all factory tested • AHRI Standard 1060-certified energy wheels • All fans are dynamically balanced in the horizontal and vertical planes. • All fans with VFDs undergo inverter balancing • Formulated panels and integral base frame minimize seams that could introduce air leak paths • Integrated raceway for wiring protection • Integrated, fully-enclosed control panel for starters, VFDs, and unit-mounted controllers • Pre-engineered, factory-mounted controls, including end devices, motor controllers, VFDs, unit-mounted DDC controllers, Traq™ damper ventilation control section, UL-listed turnkey control packages Lowest Installed Cost • Lifting lugs included on the integral base frame • Indoor units ship with skid designed for forklift transport • Variable height, size, type, and location of openings on discharge plenums minimize duct transitions • Factory-installed interoperable controls shorten construction cycles, simplify job-site coordination, reduce installation time and expense, and provide single-source responsibility for warranty and service issues • Single-point power is available with high-voltage distribution block and external main unit disconnect with lockout/tagout capabilities. • External service module with 15 amp GFCI receptacle, light switch, and controller display and communications port • Quick-connect wiring minimizes installation costs and provides wiring integrity between sections • Factory-installed conduit connectors eliminate penetrations in the wrong location • Motor leads can be run through flexible metal conduits to NEMA 4 external motor junction box • Building Information Modeling (BIM) drawings to minimize jobsite ductwork, electrical, piping and structural interference • Duct supports designed into factory roof curbs for pre-connection of ductwork For dimensional information on Performance Climate Changer air handlers see Trane catalog CLCH-PRC023-EN. CLCH-PRC022A-EN 3 Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Superior Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Industry-Leading Energy Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Optimization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Highest Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lowest Installed Cost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 2 3 3 Features and Benefits - Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Form, Function and Flexibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Reduces Footprint when Stacked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Eases Retrofit, Renovation, and Replacement . . . . . . . . . . . . . . . . . . . . . 11 Airside Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Construction and Integrity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Engineered for Good IAQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Sound-Sensitive Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Provide Accurate, Tested Sound Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Minimize Sound Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Increase Operating Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Turnkey Control Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Single-Source Responsibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single-Point Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reduced Installation Costs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reliable Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Open Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 16 16 16 17 17 Proven Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 AHRI Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Miami/Dade County Notice of Compliance (NOA) . . . . . . . . . . . . . . . . . . UL Listing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IBC Seismic Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AMCA Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Canadian Registration Number (CRN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . ISO Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 18 18 18 18 18 18 HVAC Design Fundamentals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Provide Proper Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Maintain Building Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Protect Coils from Freezing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Filter Contaminants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Particulate Filter Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Gases and Vapors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Minimize Microbial Growth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Water Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Dehumidification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 4 CLCH-PRC022A-EN Humidification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Provide Quiet Comfort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Application Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Air Handler Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Single-Path Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Dual-Path Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Standard AHU Arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Draw-Thru Arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Blow-Thru Arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Stacked Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Arrangements for Specific Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Building Pressurization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Building Pressurization with Return Fan and Economizer . . . . . . . . . . . . Building Pressurization with Exhaust Fan and Economizer . . . . . . . . . . . Building Pressurization with Barometric Relief Economizer . . . . . . . . . . Dehumidification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dehumidification with CDQ™ (Cool, Dry, Quiet) Desiccant Wheels . . . . Dehumidification with Coil Runaround Loops . . . . . . . . . . . . . . . . . . . . . Dehumidification with a Split Dehumidification Unit (SDU) . . . . . . . . . . Dehumidification with Hot-Water Heat-Recovery Coils . . . . . . . . . . . . . . 30 30 31 32 32 33 33 34 37 Energy Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Energy Recovery with a Total Energy Wheel . . . . . . . . . . . . . . . . . . . . . . 37 Energy Recovery with Coil Runaround Loops . . . . . . . . . . . . . . . . . . . . . 39 Energy Recovery with Air-to-Air Plate Frame Heat Exchangers . . . . . . . 40 Acoustics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Components and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Access/Blank and Turning Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Blender . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 CDQ™ Desiccant Dehumidification Wheel . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Coil Optimization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Drain Pans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electric Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Integral Face-and-Bypass Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 45 45 45 Dampers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Face-and-Bypass Dampers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Traq™ Dampers and Low Flow Traq Dampers . . . . . . . . . . . . . . . . . . . . . 49 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Diffuser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Discharge Plenum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Economizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Energy Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 CLCH-PRC022A-EN 5 Energy Wheels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Coil Runaround Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Air-to-Air Plate Frame Heat Exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Fan Choices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Constant Volume vs. VAV Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Airflow Measuring Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Filtration and Air Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Filtration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Air Cleaning Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Gas Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Humidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Inlet Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Mixing Box and Economizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Multizone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Silencers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Unit Size 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Unit Size 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Unit Size 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Unit Size 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Unit Size 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Unit Size 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Unit Size 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Unit Size 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Unit Size 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 Unit Size 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Unit Size 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Unit Size 26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 Unit Size 30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Unit Size 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 Unit Size 35 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 Unit Size 36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 Unit Size 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 Unit Size 41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Unit Size 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 Unit Size 51 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 Unit Size 57 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 6 CLCH-PRC022A-EN Unit Size 58 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 Unit Size 66 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 Unit Size 80 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 Unit Size 100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 Unit Size 120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 Drain Pans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 Coil Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 Hydronic and Steam Coil Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 155 Refrigerant Coil Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 Coil Circuiting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 Distributor Arrangement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 Distributor Circuiting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 Face-Velocity Limits for Moisture Carryover . . . . . . . . . . . . . . . . . . . . . . . 165 Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 Air-to-Air Plate Heat Exchangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 Blenders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 Dampers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 Energy Wheel Dampers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 Mixing Box Dampers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174 Mixing box with airfoil blade dampers . . . . . . . . . . . . . . . . . . . . . . . . . . 174 Mixing box with Traq dampers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 AMCA 610 Test Performance for Traq Damper . . . . . . . . . . . . . . . . . . . 178 Multizone Dampers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 Diffuser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 Discharge Plenums . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 Horizontal or Vertical Discharge Plenum with Factory Openings . . . . . 180 Economizer for Outdoor Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 Electric Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184 Gas Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 Hoods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 Humidifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 Multizone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 Silencers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 Trane Catalytic Air Cleaning Systems (TCACS . . . . . . . . . . . . . . . . . . . . . . 191 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 CLCH-PRC022A-EN 7 Seismic Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 Unit Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Casing Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Unit Flooring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Casing Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Drain Pans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Access Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 View Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 Marine Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 FC Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BC Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AF Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Belt-Drive Plenum Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Direct-Drive Plenum Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 195 195 195 195 Fan Isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 1-Inch, Seismic Spring Isolators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 2-Inch, Seismic Spring Isolators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 Fan Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 Fan Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Motor Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Grease Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Fan Section Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Multiple Belt Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External Motor Junction Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Motor wiring conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flow Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Belt Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Door Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 196 196 196 197 197 Fan Modulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Variable-Frequency Drives (VFDs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Inverter Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Horizontal and Vertical Coil Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inspection Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Water Coils (UW, UU, W, 5W, 5A, WD, 5D, D1, D2, P, or TT) . . . . . . . . Refrigerant Cooling Coils (UF, FD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Steam Heating Coil (NS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Coil Coating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electric Heat Coil Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Integral Face-and-Bypass Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 197 197 198 198 198 199 199 Dampers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 8 CLCH-PRC022A-EN Barometric Relief Dampers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 Energy Recovery Wheel Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 Performance and Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wheel Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wheel Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance and Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wheel Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Frost Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wheel Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 200 201 201 201 201 201 Cool Dry Quiet (CDQ™) Desiccant Wheel . . . . . . . . . . . . . . . . . . . . . . . . . . 201 Wheel Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201 CDQ Wheel Drive System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201 Maintenance and Access Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 Humidifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 Direct Steam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 Atmospheric steam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 Filters and Air Cleaners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 Permanent Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Throwaway Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pleated Media Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bag Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cartridge Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-Inch High-Efficiency Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HEPA Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ultraviolet (UVc) Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air Cleaning Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 202 202 202 203 203 203 203 204 Filter Section Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 Differential Pressure Gage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 Mixing Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 Mixing Section, Filter Mixing Section, Airflow Measurement Station (Traq™ Dampers), and Economizer Sections . . . . . . . . . . . . . . . . . . . . . Dampers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Airflow Measurement Station (Traq Dampers) . . . . . . . . . . . . . . . . . . . . Internal and External Face-and-Bypass Damper Section . . . . . . . . . . . . Internal Face Damper Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 205 205 206 206 Gas Heat Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206 Air-to-Air Plate Frame Heat Exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206 Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Corrosion Coating (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Frost Damper (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bypass Dampers (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206 206 207 207 207 Multizone Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 Two-Deck Multizone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 Three-Deck Multizone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 CLCH-PRC022A-EN 9 Double-Duct Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 Triple-Duct Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 Paint Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 Outdoor Unit Paint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 Optional Indoor Unit Paint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 Pipe Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 Outdoor Unit Roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 Silencers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 Other Sections and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 Access/Inspection Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Blender Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diffuser Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Turning and Discharge Plenum Sections . . . . . . . . . . . . . . . . . . . . . . . . Plenum Attenuation Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 208 209 209 209 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209 Combination Starter–Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Combination VFD and Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . Starter/Disconnect or VFD Enclosure Options . . . . . . . . . . . . . . . . . . . . Factory-Mounted DDC System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Direct Digital Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Factory-Mounted Control Options—Electronic End Devices . . . . . . . . . Field-Mounted Control Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 209 209 210 210 210 210 212 CLCH-PRC022A-EN Features and Benefits - Unit Figure 1. Trane Performance Climate Changer™ air handler Form, Function and Flexibility Flexibility and versatility are standard in the Performance air handler. As a customizable cataloged air handler, standard components can be arranged to meet most commercial, institutional and industrial applications for the indoor air handler market. Pre-engineered custom options expand that flexibility while ensuring proven, tested performance and dependability, and reducing the costs and long lead times associated with most custom units. Some projects call for an air handler that incorporates new, emerging technologies or a job-specific requirement. Trane’s experienced team of professionals can tailor the Performance air handler to meet these requirements. The Performance air handler design adopts a “building-block” approach that allows you to design a unit specifically for your project. Choose the “blocks” you need from the wide range of standard and custom-engineered sections, and arrange them to satisfy the air-handling requirements of the application. Reduces Footprint when Stacked The Performance unit’s design makes it easy to stack sections - even coil sections. Reducing the unit footprint is very advantageous, especially in tight mechanical rooms or limited roof space. The structural integrity remains intact, even when panels are removed for service or maintenance activities. Eases Retrofit, Renovation, and Replacement Buildings age, usage changes, loads change, new technology emerges, codes and standards are revised. Change is inevitable. The Performance air handler readily lends itself to the special needs of the renovation, retrofit, and replacement markets. The Performance air handler can be shipped in small segments that can easily be moved into tight spaces of existing buildings. CLCH-PRC022A-EN 11 Features and Benefits - Unit Airside Options Many standard options are available for specific applications, including: • • • • • • • • • • • • Exhaust or return fan economizers • Direct space pressurization control • Thermal break double-wall access doors • Thermal break casing • Factory-mounted and run-tested controls • Versatile access section lengths to meet specific needs • Multiple belt drives • Full array of pre- and final filter sections • Extended grease lines • Single-point power • LED service lights • Variable sizes, types and opening locations for discharge • plenums, plenum fans, and mixing boxes Variable height vertical discharge plenums Variable length horizontal discharge plenums Positional controls section Multiple base frame heights/multiple curb heights Single-handle, multiple latch doors External motor junction box Low-flow Traq dampers Silencers Gas heat Flush-mounted dial-type filter gauge Stainless steel inner liners Treadplate floor Construction and Integrity Trane engineered panels and doors incorporate mid-span, internal thermal breaks to eliminate thermal conduction paths from the interior of the air handler to the exterior. Likewise, door frames also feature thermal breaks to minimizing heat transfer. The panels and doors are designed to provide extraordinary insulating capabilities for efficient and cost effective performance. Panels are formulated with interlocking seam features and integral gasket seals optimized to drive down casing air leakage. The Performance air handler design is capable of meeting an ASHARE 111 Class 6 leakage level, better than most custom designs, up to +/-8 inches w.g. Standard double-wall panels and doors include two-inch closed cell foam insulation providing a minimum R-value of 13, in addition to unsurpassed panel strength and L/240 deflection at +/- 8 inches w.g. The no-through-metal design and low casing air leakage delivers thermal performance that assures condensation will not form on the casing exterior even under 55°F supply air temperature and design conditions on the unit exterior of 81°F dry bulb and 73°F wet bulb. In addition to the low air leakage, these standard features prevent equipment from unnecessarily creating slip hazards in the mechanical equipment room or premature corrosion of the casing. With this level of casing performance and thorough testing of Trane engineers, Trane is able to deliver predictable thermal performance and key guidance to consulting engineers. Heavy-duty door handles and hinges are surface-mounted, eliminating a potential leakage path since they do not pierce the casing. A removable hinge pin allows for easy door removal; the symmetrical handle and hinge mounting allows for easy field modification if it becomes necessary to change from a left-hand to a right-hand door. Engineered for Good IAQ The building industry is continuously evolving and the rate of change is accelerating. The Performance air handler is engineered to address today’s multifaceted design issues required to provide good indoor air quality (IAQ). Building owners must give particular attention to maintaining and documenting IAQ to ensure occupant comfort and to meet industry and government regulatory standards. In Standard 62.1, the American Society of Heating, Refrigerating, and Air Conditioning Engineers (ASHRAE) provides guidance regarding suitable outside air volume to be brought into the building, recommended air filtration, and design recommendations and procedures to control microbial growth. However, applying these principles may lead to greater energy consumption, larger and noisier units, and increased risk of coil freeze-up. The flexibility of the Performance air handler enables you to configure a unique, IAQ-ready air-handling system that can address all of these concerns. 12 CLCH-PRC022A-EN Features and Benefits - Unit Serviceability/Cleanability Figure 2. Smooth, interior surfaces • make cleaning easy Full-size access doors and access sections are available for easy cleaning of internal components • Fully removable coil and access panels • Smooth, cleanable interior double-wall surfaces help improve indoor air quality. • Coils are raised up out of the drain pan to make all coils removable from the side and provide easier access to the drain pan for cleaning. • Optional antimicrobial treatments for drain pans and filters. Sound-Sensitive Solutions Figure 3. Schools and auditoriums Acceptable space sound levels enhance occupant comfort and productivity. are low noise criterion However, system designs that promote good IAQ can adversely affect acoustics: (NC) applications unlined ductwork, air handlers with solid double-wall construction, and increased fan static pressures (resulting from the addition of energy recovery and increased filtration) can magnify the building’s background noise. Trane air handlers have unique product flexibility that allow designers to use them in many low-NC (noise criteria) applications. NC curves define not-to-exceed limits for a noise source to achieve a level of occupant acceptance. (See applications engineering manual FND-AM-5, “Acoustics in Air Conditioning,” for more information about NC levels.) Performance air handlers can be used successfully in NC 35 offices and schools. Provide Accurate, Tested Sound Data Traditionally, ASHRAE algorithms have been used to predict the sound power levels of air-handling units. Although this method is easy to do, it can be inaccurate. It can produce results that deviate from tested data by as much as ±15 dB. For more accurate sound data, AHRI has established Standard 260, which is a method of rating sound data for ducted air-handling equipment. It is intended to be a guide for the industry, including HVAC manufacturers, engineers, installers, contractors, and consumers. AHRI Standard 260: • Strengthens testing and calibration procedures • Provides repeatable results • Uses a reverberant-room approach, a mapped sound-rating concept, and reference soundsource calibration • Is application driven • Includes ducted outlet, ducted inlet, and casing (radiated) test configurations It is important to note that sound data for Trane air handlers is taken per AHRI Standard 260. This sound power standard covers eight octave bands (63–8000 Hz) and is unweighted (no dB corrections). AHRI Standard 260-tested sound data can be found in TOPSS. CLCH-PRC022A-EN 13 Features and Benefits - Unit Minimize Sound Source Trane air handlers have many features to optimize the source sound level for job requirements while minimizing the cost of the air handler including: Figure 4. Plenum fans help reduce • noise levels A variety of fan types to minimize the sound generated by the fan and to optimize cost no matter the application. • Double-wall perforated insulation helps attenuate high-frequency noise. • Two-inch discharge plenums reduce turbulence and create an end reflection that dampens low-frequency sound. The 2-inch perforated liner option attenuates higher frequency sound. • Turning modules used to turn the air and reduce turbulence work as effective, low-cost silencers. • Silencers for horizontal or vertical discharge in the plenum fan section come in 3-ft. and 5-ft lengths. They are dissipative or film-lined for hospital and cleanroom applications. For more information on how to apply these options in your air handler, contact your local Trane sales representative. Increase Operating Efficiency The Trane EarthWise™ system is a design philosophy that uses low flow rate and low temperature on both the waterside and airside, along with high-efficiency equipment. Along with reducing emissions, it also reduces first cost, lowers operating costs, and improves the acoustical characteristics and comfort of the HVAC system. Low-temperature, low-flow systems can challenge conventional cataloged air-handling units. The flexibility of the Performance air handler makes it ideally suited for low temperature applications. In addition: • Trane has developed a unique high-efficiency fin surface that allows face velocities in excess of 625 fpm without moisture carryover. The fins have been engineered and tested to meet these higher face velocities at a given set of design conditions. This allows you to utilize the latest in airside heat transfer to further improve the efficiency of the overall system by lowering the coil approach temperature. • The ability to choose the exact number of fins per foot of coil surface allows heat transfer and air-pressure-drop performance to be tuned to specifically meet project needs. • The wide array of fan options lets you choose the right fan for the application. • Factory-engineered, -mounted, and -tested controls provide the added insurance that the airflow sensors and sequences meet your requirements. • Further system enhancements can be made by taking advantage of the latest controls technology with fan pressurization control (required in most variable-air-volume systems per ASHRAE Standard 90.1) and/or ventilation reset of the outside air damper based upon occupancy levels in the space. Turnkey Control Solutions Trane air handlers offer one of the most comprehensive factory-packaged controls systems available, from end devices to total system integration, with industry-standard open protocols. An air handler turnkey control package can be used in a stand-alone operation, or it can be fully integrated into a comprehensive control system. Trane’s Integrated Comfort™ system (ICS) incorporates the benefits of factory-installed controls and links the air handler to the Tracer Summit™ building management system. 14 CLCH-PRC022A-EN Features and Benefits - Unit These options are designed to lower installation costs and risk while dramatically improving the quality of the application and the performance of the air handler. The entire air handler control system is engineered, mounted, wired, and tested before leaving the factory. As a result of strict quality manufacturing methods, Tracer control options bring consistency and reliability to the control-system package and provide single-source responsibility. The following control devices are available as standard mounted on fan sections or within the positional controls section: • Combination starters and disconnects – International Electrotechnical Commission (IEC) standards • Variable-frequency drives (VFDs) – Drive/OFF/Bypass selector switch – Digital manual speed control – Three-year parts and labor warranty – Open drive to provide easy serviceability • Unit-mounted direct digital controllers (DDCs). – A factory-wired and mounted Tracer programmable controller is available. The following end devices are also available: • • Valves Electronic damper actuators • Temperature and pressure sensors – Available in multiple temperature sensor materials Averaging temperature sensors – Available in multiple temperature sensor materials Fan and filter status switches Low-limit switches (see Figure 6) – Double pole, single throw, manual reset • • • • • Figure 5. Integral controls cabinet for starters, variable frequency drives, and unit controllers – Available wired to low voltage and high voltage Condensate overflow switches Humidity sensors Figure 6. Factory-mounting ensures quality installation, as shown with the low-limit radius bend Single-Source Responsibility Equipment and interoperable controls, engineered and provided by a single manufacturer, provide faster construction cycles and simplify job-site coordination efforts. This simplification reduces installation time, expense, and risk.Trane equipment and controls package provides the optimal performance when integrated with a Tracer building management system, forming a Trane Integrated Comfort™ system (ICS). ICS is a powerful system architecture that unifies Trane HVAC equipment, direct digital control, and building management into a cohesive whole with an assured source of support. This system is managed with the Tracer Summit building management system. The Tracer Summit building management system is based on ASHRAE and American National Standards Institute (ANSI) BACnet Standard 135. CLCH-PRC022A-EN 15 Features and Benefits - Unit Single-Point Power For air-handling units requiring a supply fan with a return/exhaust fan, electric heat, gas heat or CDQ, we can supply single-point power. Single-point power wiring includes a high voltage distribution block and main unit disconnect with lockout/tagout capabilities. From a single line voltage connection, power is provided to all components including controls and service lights. Single-point power wiring does not compromise the UL or ETL certification of the unit. Reduced Installation Costs Figure 7. Quick-connect wiring While the air-handling system is in the factory, trained technicians install the control end devices and controllers using state-of-the-art equipment and agencyapproved wiring practices. The system is pre-designed, pre-engineered, and checked out, making jobsite installation and commissioning fast and easy. While many of these tasks and procedures could be done in the field, it is beneficial to do them in the factory due to time and accessibility constraints. As a result, field expenses for installation costs of conduit and wire are minimized, additional leadtime is alleviated, and jobsite coordination is simplified. Casing integrity is also maintained by minimized penetrations. Factory wiring minimizes installation costs, too. Quick-connect wiring (see Figure 7) ensures integrity between sections without having to identify or check continuity. After installation, Tracer controllers enable information-sharing and complex control strategies, such as ventilation reset, throughout the HVAC system. They also ensure that each subsystem operates in the most efficient manner possible while continuing to satisfy current loads. The result is reduced building energy consumption through effective operation of the entire HVAC system at part-load conditions. Trane ICS incorporates the latest energy-saving concepts to produce comfort at the lowest possible cost. In addition, it offers sophisticated building management features, such as after-hours billing, for commercial properties. This revenue opportunity enables developers and owners to accurately monitor and bill the cost incurred by a single tenant in after-hours usage of a facility. An optional DDC variable-air-volume (VAV) capability helps to accurately control each tenant space so that only an individual tenant’s HVAC systems are activated. This helps minimize operating costs while providing flexible work hours. Reliable Operation Controller end devices, such as low-limit switches and averaging temperature sensors, are properly sized, selected, laboratory-tested, and mounted for optimal system performance. Trane engineers its unit-mounted controllers to provide the highest level of useful information possible. A computer-based test station tests low-voltage end-device functionality and surveys the input devices. This procedure ensures trouble-free installation and reliable operation when the Performance air handler reaches the job site. This feature can limit the number of call-backs and punch-list tasks. Incorporating a Performance air handler with Trane ICS provides an engineered system of proven components and comfort concepts that is both state-of-the-art and reliable. Standard components are used to aid in serviceability and uniformity from building to building. These components, when tied to a Tracer Summit system, provide a powerful tool for scheduling preventive maintenance, reducing equipment downtime, and controlling service expense. 16 CLCH-PRC022A-EN Features and Benefits - Unit Open Protocol Trane Tracer™ controllers bring open communication protocols to the product offering. For building-level and unit level communications, Tracer controllers use BACnet®. BACnet is a standard, open communications protocol that allows integration and interoperability, enabling the controllers to not only tie into a Tracer Summit system, but also other building automation systems. At the unit level, Trane can also use LonTalk® for peer-to-peer communication between Trane controllers and other approved LonTalk controllers. Trane can provide a factory-wired terminal strip that can be wired into a field-mounted controller. The programmable controller (MP581) follows the certified Space Comfort Controller (SCC) profile for constant-volume systems and the Discharge Air Controller (DAC) profile for constant-volume or VAV systems. Adherence of this controller to these standardized, certified profiles enables it to communicate with other controllers that use the same certified LonTalk profiles. Go to www.lonmark.org for more information. Service Module Figure 8. The service module can include a 15-amp GFCI. Performance air handlers can be equipped with an easy access Service Module when a Trane programmable controller and/or service lights are factory mounted. All service lights are wired to a common switch within the Service Module, located either on the fan section or the controller cabinet. The Service Module can also include a 15-amp ground-fault circuit interrupter (GFCI) receptacle separate from the load side of the equipment, a National Electrical Code (NEC) requirement. When an MP580 controller is factory mounted, the Service Module will have communications and portable display ports allowing service personnel to perform diagnostics without opening the unit or controller panel. Proven Performance AHRI Standards Figure 9. AHRI Standard 430 Trane combines comprehensive performance certification by AHRI with thorough laboratory testing and advanced manufacturing methods. Together, these elements help assure that each Trane air handler operates predictably and reliably throughout the life of the unit. Figure 10. Unlike other rating methods that check fan performance alone, Trane units are performance-tested in accordance with AHRI Standard 430. This certification process evaluates the air handler on the basis of airflow, static pressure, fan speed, and brake AHRI Standard 410 horsepower. Heating and cooling coils are rigorously tested and certified with AHRI Standard 410 to assure that they, too, deliver published performance. AHRI Standard 260 is the first ducted-air-handler sound rating procedure. It is intended to provide engineers with better, more accurate, ducted sound power levels so that they can design quieter and more cost-effective comfort systems. Sound ratings for Trane air handlers have been developed from extensive AHRI Standard 260 testing and laboratory data. CLCH-PRC022A-EN 17 Features and Benefits - Unit Miami/Dade County Notice of Compliance (NOA) Performance Climate Changer air handlers size 3-30 are approved and have has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. Each qualified unit shall bear a permanent label with the Trane name and logo and the statement “Miami-Dade County Product Control Approved”. Notice of compliance and additional product construction details can be found at the Miami-Dade County, Building Code Compliance Office Web site, under NOA No. 11-0926.08). Testing is currently underway for unit sizes 35-120. UL Listing Trane air handlers are UL-listed to U.S. and Canadian safety standards. IBC Seismic Certification Air handling equipment manufactured by Trane is capable of structurally and operationally withstanding the seismic response criteria as required by the International Building Codes (IBC) 2000,2003, 2006, 2009. Trane has third-party certification for IBC compliance for seismic applications for unit sizes 3-30. Certification for larger sizes is in process. AMCA Certification Trane utilizes AMCA certification for airflow measuring stations. Trane certifies that the TraqTM damper shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 611 and comply with the requirements of the AMCA Certified Ratings Program. This certification program provides the engineer and owner assurance that manufacturer-published performance ratings for airflow measurement stations are accurate and repeatable. Trane Traq dampers are certified with the integral ventilation control module (VCM) which converts differential pressure to an electronic signal for control. Canadian Registration Number (CRN) The Canadian Registration Number, or CRN, is given to companies that comply with Canada’s Technical Safety Standards Act concerning pressure vessel safety. In Trane air-handling systems, the CRN applies to coils classified as Category H fittings. Most government and industrial customers require the HVAC supplier to have a CRN. Trane has earned a CRN for all steam and water coils. used in the Performance air handler. ISO Certification Certification by the International Standardization Organization (ISO) ensures that an organization can consistently deliver a product or service that meets the customer’s contractual requirements by following documented processes. The ISO 9001 quality assurance model establishes the requirements for an organization whose business processes range from design and development to production. Having the quality management system of our manufacturing plants ISO 9001certified directly benefits Trane customers because our continuous process improvements can reduce business costs, improve product quality, and enable faster ship cycles 18 CLCH-PRC022A-EN HVAC Design Fundamentals In essence, an air-handling unit, or AHU, is exactly what its name implies: a device that “handles” (moves and/or conditions) air. It accomplishes this based on the functions required by a given application, as well as the arrangement of components necessary for those functions. Trane air handlers can accommodate an extraordinary degree of design versatility, but in order to apply that versatility to each unique application, an HVAC designer must: • Design the air handler in a manner consistent with good HVAC design practices. • Understand the impact of ASHRAE Standard 62.1, Ventilation for Acceptable Indoor Air Quality, and ASHRAE Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings, on AHU functions and design. • Know how specific components can address application requirements, with arrangements optimized for job requirements, thermal performance, and acoustical performance. • Deliver the performance you have designed with a well-functioning control system. Provide Proper Ventilation Ventilation is the process of diluting the build-up of contaminants by introducing clean, fresh outdoor air into buildings. The lack of proper ventilation is identified as a leading cause of poor indoor air quality (IAQ) problems. ASHRAE Standard 62.1 sets the minimum ventilation rates and specifies basic HVAC equipment and system requirements to provide “acceptable indoor air quality.” ASHRAE Standard 62.1 is considered the standard of care for designers to assure good IAQ in commercial buildings. Assuring proper ventilation levels at all operating conditions can be challenging for a designer. Fixed outdoor-air damper arrangements on variable-air-volume systems can result in severe underventilation of the occupied spaces at part-load conditions. The Performance air handler is available with the patented Traq™ outdoor airflow measurement and control damper, which can precisely control the volume of ventilation air entering the system and even dynamically vary the amount in response to specific operating conditions. With the Traq damper, the amount of outdoor air can be continuously logged using a Tracer Summit™ building automation system to document proper ventilation. Maintain Building Pressure An important aspect of establishing outdoor-air requirements is equalizing outdoor-air and exhaust-air volumes to maintain proper building pressurization (see Figure 11). Building pressurization describes an air-handling strategy that regulates pressure differences across the building envelope and between zones or rooms by adjusting the amount of air that is supplied and removed. The goals of this strategy are to: CLCH-PRC022A-EN • Assure proper distribution of conditioned and ventilation air throughout the occupied space • Avoid discomfort due to temperature stratification and drafts • Prevent infiltration of unconditioned air • Confine odors and contaminants to specific areas within the building 19 HVAC Design Fundamentals Figure 11. Maintain proper building pressurization Building-envelope pressurization is typically achieved by incorporating either an exhaust fan and economizer or a return fan and economizer in the air handler design. Careful analysis is required to determine which approach best suits the unique requirements of each application. To better understand the differences between exhaust-fan and return-fan systems, consult your local Trane sales representative or refer to applications engineering manual, Building Pressurization Control (AM-CON-17). Protect Coils from Freezing Figure 12. Protect coils from freezing by addressing air stratification Cold Air Outside Air Mixed Air Warm Air Return Air 20 CLCH-PRC022A-EN HVAC Design Fundamentals Figure 13. Low-limit sensor When bringing more outdoor air into the air handler to satisfy the ventilation requirements of ASHRAE Standard 62.1, it increases the likelihood of air stratification (see Figure 12). If a layer of freezing air moves through the air handler, it can damage unprotected, hydronic cooling and heating coils. Traditional freeze protection includes a low-limit thermostat (see Figure 13) (installed on the face of the cooling coil) that trips when it detects a dangerously low air temperature. When this happens, it stops the supply fan, closes the outdoor air damper, and ultimately degrades the building IAQ. It is important to design the air handler so that it effectively treats the required amount of outdoor air—regardless of temperature—without risking coil damage, tripping the low-limit thermostat, or compromising indoor air quality. Trane has several means of providing coil protection. Choose the technique that best suits the application requirements. • Drain the coils. This approach necessitates vent and drain connections on every coil, plus shutoff valves to isolate them from the chiller(s). • Add glycol and an inhibitor to the cooling system water. The glycol lowers the water freezing point, and the inhibitor helps to resist corrosion. • Introduce ventilation air downstream of the cooling coil with dual-path or bypass techniques. • Preheat the outdoor air stream. Use a traditional or integral face-and-bypass steam coil or a hot hydronic coil to raise the air-stream temperature above freezing. • Use a blender section (see Figure 14). This approach mixes the outdoor and recirculated air streams to address air stratification. Figure 14. Blender Filter Contaminants Particulate Filter Guidelines The Environmental Protection Agency (EPA) and ASHRAE recommend that the concentration of particulates in the air not exceed 0.05 mg/m3 (measured as an annual mean). This guideline is established in an EPA PM-10 standard which focuses on smaller particulates (<10 microns) that are likely responsible for adverse health effects because of their ability to reach the lower regions of the respiratory tract. ASHRAE Standard 62.1 and the U.S. Green Building Council LEED rating system emphasize the importance of including appropriate filters in the air handling system to effectively control particulate contaminants. Both establish minimum requirements for filter performance applied within a commercial building based on ASHRAE Standard 52.2, Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size. This standard establishes a test procedure for evaluating the performance of air-cleaning devices as a function of particle size (0.3 to 10 microns). A minimum efficiency reporting value (MERV) is assigned to a filter based on its efficiency in three different particle-size ranges (0.3 to 1 microns, 1 to 3 microns, and 3 to 10 microns). A higher MERV rating indicates a greater ability to remove high quantities of small particles from air. CLCH-PRC022A-EN 21 HVAC Design Fundamentals ASHRAE Standard 62.1 recommends a minimum MERV 6 filter, while the USGBC LEED rating system recommends a minimum MERV 8 during the construction cycle and MERV 13 during normal operation. National, state, or local codes established by government bodies or occupational groups may dictate more specific or stringent filtration requirements. Selecting the appropriate filter relies on understanding the particles that need to be filtered and their size. Table 1 provides design guidance for which filter option should be applied in your air handler. Table 1. MERV ratings versus particle size efficiencies MERV Value Group 1 Avg. Eff.% 0.3 to 1.0 microns Group 2 Avg. Eff.% 1.0 to 3.0 microns Group 3 Avg. Eff.% 3.0 to 10.0 microns 1 n/a n/a E3<20 2 n/a n/a E3<20 3 n/a n/a E3<20 4 n/a n/a E3<20 5 n/a n/a 20<35 6 n/a n/a 35<50 7 n/a n/a 50<70 8 n/a n/a 70 9 n/a E2<50 85 10 n/a 50<65 85 11 n/a 65<80 85 12 n/a 80 90 13 E1<75 90 90 14 75<85 90 90 15 85<95 90 90 16 95 95 95 17 99.7 Figure 15. Use proper filtration General Applications Residential Light Commercial Commercial Industrial Better Residential Commercial Telecommunications Industrial Superior Commercial Health Care Hospitals General Surgery Surgery, pharmaceutical manufacturing Gases and Vapors The presence of various undesirable gases and vapors (particularly formaldehyde, radon, oxidants, and volatile organic compounds, or VOCs) indoors can be detrimental to building occupants, materials, and contents. Controlling VOC concentrations is particularly challenging—hundreds of them are present, few are unique to any one source, and there are many potential sources, some of which emit several VOCs. A common way to control gaseous contaminants is to dilute them with outdoor air. This approach is appealing because many VOCs defy individual treatment. However, it is only practical if the quality of the outdoor air is suitable and if the resulting supply airflow is consistent and appropriate and if it mixes effectively with the air in the occupied space. Another approach is to neutralize the contaminants in the air. This can be done through air cleaning mechanisms UVc/PCO technology to reduce volatile organic compounds (VOC’s) through photocatalytic oxidation without the creation of ozone or by-products. 22 CLCH-PRC022A-EN HVAC Design Fundamentals Minimize Microbial Growth Figure 16. Keep surfaces clean Although filtration effectively removes a number of common particulate and gaseous contaminants from the building environment, microbiological, or microbial, contaminants such as fungi (mold and mildew) and bacteria are sometimes too small to be filtered entirely from the air stream. To help control microbial growth, design the air handler to include: • Non-porous, cleanable interior wet surfaces • Easy access to all areas of the air handler for inspection, service, and cleaning. • Use of ultraviolet (UV) germicidal irradiation lights Regular cleaning and disinfecting with nonpolluting cleansers and antimicrobial coatings also helps, but none of these measures totally eliminates the growth of ever-present microorganisms. Consequently, moisture control becomes another important means of combating microbial contaminants. Water Management Cooling coils collect water from the passing air stream as they cool and dehumidify it. If not properly addressed, this condensed moisture encourages mold, mildew, and other microorganisms to colonize and breed. To reduce the likelihood of microbial growth: CLCH-PRC022A-EN • Reduce moisture carryover by sizing the cooling coils for proper airflow velocities. Trane coils can be sized for velocities in excess of 625 fpm without moisture carryover, depending on air conditions, coil size, and coil-fin type and spacing. Refer to “Coils” section on page 155 for the moisture-carryover curves and details about allowable velocities. • Specify drain pans sloped in two planes to eliminate stagnant water conditions and to promote positive drainage. • Locate coils on the second level of a stacked air handler to provide adequate trapping height. • Properly size condensate traps to ensure proper drainage. See Figure 17. • Promote cleanability by providing adequate space around the unit, easily removable access panels, and a solid steel liner to isolate insulation from the air stream and to facilitate cleaning. Also, provide extended drain pans to allow for periodic cleaning. • Condition the mechanical equipment room to prevent condensation on piping, ductwork, mechanical equipment, and other surfaces. 23 HVAC Design Fundamentals Figure 17. Drain pan trapping for positive and negative pressure applications H L J Drain pan trapping for section under negative pressure Drain pan trapping for section under positive pressure L = H + J + pipe diameter where: H = 1 inch for each inch of negative pressure plus 1 inch J = 1/2 H L = H + J + pipe diameter where: H = 1/2 inch (minimum) J = 1/2 inch plus the unit positive static pressure at coil discharge (loaded filters) Dehumidification ASHRAE Standard 62.1 observes that “high humidities can support the growth of pathogenic or allergenic organisms” and suggests that the relative humidity of the occupied space not exceed 60 percent. Higher humidities also require lower supply-air temperatures for thermal comfort. Most climates require dehumidification to achieve this design goal. Dehumidification can be accomplished by removing moisture from the air, that is, condensing the water vapor on cooling coils. However, cooling coils can over cool the occupied space when dehumidifying at sensible part-load conditions. There are several ways to control to both humidity and temperature at part load conditions. 24 • Use a VAV air handler versus a constant volume air handler. This can improve part load dehumidification. • Use desiccant dehumidification systems to dehumidify and control humidity to very tight tolerances. • Use a split dehumidification unit (SDU) to improve dehumidification by treating the ventilation air separately. • Use a s Dedicated Outside Air Unit, DOAS, to dehumidify the ventilation air. CLCH-PRC022A-EN HVAC Design Fundamentals • Use a reheat coil, which can be accomplished using recovered condenser heat energy or with standard electric or hot water coils. Humidification Low relative humidity - below 30 percent - in an occupied space is also undesirable because it requires higher supply-air temperatures for thermal comfort and promotes static electricity. Raising the space humidity to an appropriate level requires a humidifier to inject water particles into the passing air stream. To avoid promoting microbial growth, the unit design must assure that the injected water is fully absorbed within the air handler without collecting on its walls or components. Three types of commercial humidifiers are generally used in central-station air-handling systems: wetted media, atomized water, and steam. Of these types, ASHRAE Standard 62.1 prefers steam “as the moisture source for humidifiers.” The temperature and pressure properties of steam make it easy to introduce directly into the passing air stream and encourages complete absorption in a short distance. Trane standard humidifier sections incorporate all the distance required for absorption to occur. Application Considerations: • Never position the humidification section immediately downstream of a housed fan or blowthru coil section. • Extra dispersion distance may be needed if the humidification section is placed upstream of a final filter or electric heat coil. • Vertical airflow turns immediately upstream and downstream of the humidification section necessitate a large section. Provide Quiet Comfort Figure 18. Trane acousticians collect and test sound data Acceptable sound levels inside a building can improve occupant comfort and productivity. In fact, achieving an acceptable acoustical environment today is almost as important as simply conditioning it. To meet space sound levels, be sure to optimize the noise source (the air handler) using path attenuation (ducts, wall, and room carpeting). The sound source can be projected using Trane TOPSS selection program or with the Trane CLCHLw program. The sound path can be projected using the Trane Acoustical Program (TAP). Compare the resulting NC projection with the designed value. If the NC projection is too high, the air handler can be made quieter with a selection focused on acoustics, or the path attenuation can be increased—or both strategies can be combined. In the end, the projection should meet the NC requirements for your job. Creating quiet spaces is increasingly difficult because of the trend toward “IAQhardened” systems. “IAQ hardening” involves removing fiberglass insulation, which acts as a sound absorber, from inside the ducts and even the units. Without this insulation, the air handler makes too much noise. With Trane’s acoustic options and the TOPSS selection program, you can create the unit you need for your quiet application. With these options, you can select an air handler that is more than 20 dB quieter than a conventional unit. The starting point is the Trane AHRI Standard 260 sound database. Trane sound power ratings cover eight octave bands (63–8000 Hz). Data is collected in one of Trane’s ANSI 12.32-qualified reverberant rooms. CLCH-PRC022A-EN 25 HVAC Design Fundamentals To determine the most cost-effective acoustical solution for a given application, follow these steps: Select the unit and predict the unit sound power using the TOPSS selection program. Project the sound to the space using TAP. Optimize the unit sound (fan, plenums) with the path attenuation (ductwork and ceiling) for the lowest first cost that meets the sound requirements. Table 2 summarizes the noise reduction ideas accumulated by Trane engineers during four decades of experience with central-station air handlers. Use the TOPSS program to predict the effect of each idea. However, for acoustically sensitive applications, we strongly recommend that you work with your local Trane sales representative to find the most cost-effective solution that meets your job requirements. Table 2. Noise reduction suggestions Targeted Sound Overall unit sound power (Lw) Discharge sound power Inlet sound power 26 Suggestions • • • • • • • • • • • • In VAV systems, use variable-frequency drives for fan modulation. Change fan types. Increase the fan size. Use a central exhaust fan rather than a return fan. Use discharge plenums. Use outlet silencers. Use perforated walls. Use multiple-discharge plenum outlet ducts. Use discharge plenums with side openings. Use a large inlet plenum. Use inlet silencers. Stack the inlet sections. CLCH-PRC022A-EN Application Considerations The first things to consider when selecting an air handler for any given application include: • Design. Which overall system design best suits the required function? • Arrangements. What is the best section arrangement for the specified function and layout? • Components. Which components should be selected to support the function, layout, and arrangement of the application? Air Handler Design Which design best suites the application? After determining the required airflows and functions for a particular application, the HVAC designer must determine which one of two path layouts for outdoor air best serves the application: single-path or dual-path. Single-Path Design Single-path AHUs (see Figure 19) rely on one outdoor air path. Depending on application requirements, that path may provide ventilation air only or both ventilation air and economizing air for natural, non-mechanical cooling. Components for filtering and tempering the air are arranged in series. The single-path layout can accommodate passive or powered return- and/or exhaust-air paths as well as energy recovery. Figure 19. Single-path design CLCH-PRC022A-EN 27 Application Considerations Dual-Path Design Dual-path AHU (see Figure 20) layouts provide two air paths. Like a single-path design, dual-path designs can incorporate basic outdoor air, recirculation, exhaust-air, and energy-recovery functions. However, one path is dedicated to handling ventilation air to specifically address ASHRAE Standard 62.1 requirements. Each path is provided with its own air treatment components such as filters and heating and cooling coils. Figure 20. Dual-path design Application considerations: • Reduces or eliminates reheat requirements, while providing an effective means of dehumidification for loads with low sensible-heat ratios (high latent cooling requirements) • Avoids increasing supply-fan static pressure due to high pressure drop components in the ventilation air stream (increases latent cooling and filtration capacity without increasing fan size) • Permits downsizing of the ventilation-path components • Enables compliance with the ASHRAE Standard 62.1 requirement for measuring outdoor airflow without significantly increasing the first cost of the air handler • Provides a cost-effective means to increase ventilation airflow in an existing system • Reduces cost by reducing the number of units (dedicated outdoor-air units can be eliminated). Figure 20 represents a sample dual path configuration. For more design options, see Trane Application Engineering Manual for Dehumidification in HVAC systems (SYS-APM004-EN). 28 CLCH-PRC022A-EN Application Considerations Standard AHU Arrangements To complete the air-handling system, the sections must be physically arranged in a way that fits the available space. Conventional descriptions of air handler arrangements, draw-thru and blow-thru, reflect the means of establishing airflow through the coil based on the position of the coil relative to the fan: the fan either draws air through a coil located upstream or blows air through a downstream coil. Trane adds another dimension to air handler arrangements, letting you combine sections by stacking them on top of each other in space-saving configurations, by coupling them together with transition panels, or by combining both techniques. Careful evaluation of the merits of each arrangement is a critical part of the design process. Draw-Thru Arrangements A draw-thru AHU arrangement places the coils and filters upstream of a ducted supply fan. It can be single- or dual-path. Horizontal Draw-Thru Accepted system design practices are generally the only restrictions in a horizontal draw-thru application. However, certain application rules must be followed to promote proper airflow through filters and coils. Vertical Draw-Thru Trane air handlers in a vertical draw-thru arrangement typically result in a shorter footprint than horizontal draw-thru units. This arrangement stacks a fan on top of a vertical coil section. When designing an air handler in this configuration: • The bottom deck must be equal to or longer than the fan section to avoid creating a “cantilever” effect. • A vertical draw-thru fan performance curve should be used to account for the airflow impingement by a coil installed in a vertical coil section. Blow-Thru Arrangements This type of AHU arrangement places the cooling coil downstream of the supply fan. Single-Zone Blow-Thru Medium coil This type of arrangement can provide only one supplyair temperature from the unit. To promote proper air distribution through each section and to reduce the risk of moisture carryover, certain application considerations apply based on the fan type. Access CLCH-PRC022A-EN Access Fan Filter and mixing box 29 Application Considerations Stacked Units A stacked AHU arrangement can be either draw-thru or blow-thru. It places the air handler sections on top of each other. This strategy can significantly reduce the length of the unit and provide better acoustical performance, yet has very little effect on unit static pressure drops. Application considerations: • Stacked section weight must not exceed the maximum stacking weight of the casing. • Ductwork and dampers must not interfere with stacked sections. • “Upper-deck” sections cannot overhang lower sections. • Intermediate support brackets should be used if the width of the upper deck is less than that of the bottom deck. Arrangements for Specific Applications Draw-thru and blow-thru arrangements for Trane air handlers can be engineered for specific applications, including those to maintain proper building pressure, dehumidify, and recover energy. Building Pressurization Return fans and exhaust fans are used to maintain building pressurization. A Trane air handler can include either of these components. To better understand the differences between exhaust-fan and return-fan systems, consult your local Trane sales engineer or refer to the Trane applications engineering manual, Building Pressurization Control (AM-CON-17). Building Pressurization with Return Fan and Economizer Figure 21 depicts a standard air handler with a return fan and an economizer for outdoor air. The return fan typically runs continuously to balance the amount of air supplied to and removed from the occupied space. Although this approach makes precise space pressurization control more difficult, it is better suited to applications with high return static pressures than the exhaust-fan alternative. If the supply fan is unable to handle system static pressure, the return fan is sized to overcome the external static pressure of the return duct. Of course, the larger size and constant operation of the return fan also means higher first and operating costs. Figure 21. Return fan and economizer arrangement for outdoor units Airflow Airflow Airflow Return fan Economizer Supply fan Coil Filter Airflow 30 CLCH-PRC022A-EN Application Considerations Application considerations: • Size the supply fan to handle the static pressure requirements of a 100-percent economizer operation, including outdoor-air ductwork, dampers, filters, coils, other accessories in the outdoor air stream, and supply-duct static pressure. • Size the return fan to handle the static pressure requirements of a 100-percent return air operation, including return duct, exhaust duct, and exhaust damper. • Control the return fan to keep the outdoor/indoor static-pressure differential within design limits. • Control the mixing box dampers to prevent all of them from closing simultaneously; otherwise, serious equipment damage could result. Building Pressurization with Exhaust Fan and Economizer Figure 22 depicts a standard air handler with an exhaust fan and an economizer for outdoor air. To balance the amount of air exhausted from the building with the amount of air brought into the building, the exhaust fan modulates, running at full capacity only when the economizer brings in 100 percent outdoor air. When the economizer is at minimum and the exhaust fan is idle, dampers on the mixing box close to prevent outdoor air from being drawn into the air handler through the exhaust section. Figure 22. Exhaust fan and economizer arrangement The exhaust-fan-and-economizer combination provides strict space pressurization control, provided that the supply fan is sized to handle total system static pressure. Its first cost and operating cost are usually lower than the return-fan-and-economizer alternative, too. (An exhaust fan requires less capacity than a return fan and runs less often.) Application considerations: CLCH-PRC022A-EN • Size the supply fan to handle the static pressure requirements of the higher of either a 100percent economizer operation or 100-percent return-air operation. • Size the exhaust fan to handle the static pressure requirements of a 100-percent return-air operation, including return duct, exhaust duct, and shutoff damper, when the unit is in full economizer mode. • Control exhaust airflow to keep the outdoor/indoor static-pressure differential within design limits. • Control the mixing box dampers to prevent all of them from closing simultaneously; otherwise, serious equipment damage could result. 31 Application Considerations Building Pressurization with Barometric Relief Economizer Figure 23 depicts a typical air handler with a barometric relief economizer. Barometric relief offers some positive space pressure control. The equipment consists of an economizer section with a damper in the return air path that opens upon an increase in pressure difference between the space and the outside. The supply fan must over-pressurize the space to allow for proper operation of the barometric damper. It should only be used in systems that have extremely low return air static requirements. In other systems, it is recommended that a powered system such as return fan or exhaust fan economizer be used instead of barometric relief. Figure 23. Building pressurization with a barometric relief economizer arrangement Barometric relief economizer Coils Supply fan Mixing section (Return air opening) Access Application Considerations: • Size the supply fan to handle 100 percent outside air operation (i.e. OA hood, OA dampers, filters, coil(s) and other accessories, plus supply air ductwork). • Set up system for maximum delivery at 100 percent OA economizer mode. Turn on all remote exhaust fans. Measure the space static pressure, and adjust barometric relief damper to produce a slight positive space pressure. • Only when the unit is at or near 100 percent OA (return air damper is closed) will the exhaust section become sufficiently pressurized to open the barometric damper. Dehumidification Excessive humidity in buildings can encourage mold and mildew growth and thermal discomfort. To cost effectively address these issues, first isolate the conditioned space from the unconditioned space. (See Trane applications engineering manual, Managing Building Moisture, SYS-AM-15.) Next, remove the humidity. The two primary humidity sources in most buildings are people and outdoor air. In any coil-based HVAC system, it is the cooling coil that dehumidifies the air. This coil must be on and air must pass through it for dehumidification to occur. In Trane air handler enhanced dehumidification units, the priority for the cooling coil is humidity control. Temperature control is secondary and is generally provided by a separate reheat source. Dehumidification can be obtained using: • CDQ™ (Cool, Dry, Quiet) units with desiccant dehumidification wheels • Series, coil run-around loops • Split dehumidification units (SDU) Free reheat options with dehumidification include: 32 • Hot water heat-recovery coils • Refrigerant heat-recovery H coils CLCH-PRC022A-EN Application Considerations Dehumidification with CDQ™ (Cool, Dry, Quiet) Desiccant Wheels The addition of the CDQ desiccant wheel to the system enhances the dehumidification performance of the traditional cooling coil (see Figure 24). The CDQ wheel transfers water vapor and the cooling coil does all the dehumidification work in the system. The latent capacity of the cooling coil increases without increasing its total cooling capacity. The system can achieve a lower supply air dew point without lowering the coil temperature. Unlike a system with a cooling coil alone, the dew point of the air leaving the coil can be lower than the dry bulb temperature leaving the coil. Figure 24. Dehumidification with CDQ (Cool, Dry, Quiet) desiccant dehumidification units Process components Humidy during the CDQ process CDQ desiccant wheel Leaving regeneration air Fan Entering air Humidity level Regeneration Condensation Adsorption Leaving cooling coil air Leaving regeneration Entering air Leaving cooling coil Water vapor Cooling coil Leaving air Leaving air Condensate Stage of process Application Considerations: • Increased cooling coil latent (dehumidification) capacity • Lower achievable supply-air dew points. • Decreased need for reheat • Lower unit cooling sensible heat ratios. • Warmer required chilled water temperatures. • Improved energy efficiency for dehumidification. • Decreased required cooling capacity when dehumidifying. • Eliminates exhaust air as a requirement For application guidelines concerning CDQ, refer to Trane engineering bulletin CLCH-PRB020-EN. Dehumidification with Coil Runaround Loops Series, coil run-around loops (see Figure 25) consist of finned-tube water coils connected in a closed loop that is “wrapped” around an active cooling coil. Operation is psychrometrically similar CLCH-PRC022A-EN 33 Application Considerations to the air-to-air, fixed-plate heat exchanger. The first coil in the loop precools the incoming outdoor air. The active cooling coil absorbs more heat from the air stream and further dehumidifies the air to the design point. The second coil in the loop is placed after the active cooling coil and reheats the air with the heat absorbed by the first coil. Loop components include a pump to move the fluid within the loop and an expansion tank. Series, coil runaround loops occupy little space and have a relatively low first cost. Like the series air-to-air, fixed-plate heat exchangers, series coil loops are only effective during the cooling season. Additional heating may be required on cool, humid or cold days. Figure 25. Series dehumidification with coil run-around loops Application Considerations: • Provide free reheat at design conditions • Allow downsizing of new energy cooling and reheat coils • Add a minimal pressure drop through each coil (only 0.3 to 0.6 in. wg) • Are available in all Trane units • Can be fully modulated by varying water flow Dehumidification with a Split Dehumidification Unit (SDU) The SDU is a dual-path, return-air-bypass air handler. It consists of two units that are stacked together in a draw-thru arrangement that share one supply fan (see Figure 26). All of the ventilation (outdoor) air is ducted to the upper unit where it is dehumidified, typically down to 50ºF or lower. The lower unit is sized to handle the return air needed to achieve the desired air-change rate in the space. The warmer return air in the lower unit mixes with the cooler, drier air from the upper unit. The resulting mixed air provides humidity control by achieving a sensible heat ratio (SHR) of down to 0.4, but also provides sensible reheat without using any new energy. A vertical unit stacks the supply fan on top of a vertical coil module; the outdoor air enters the back of the fan module. This unit is shorter than the horizontal SDU. Outdoor air economizers can also be used with an SDU. Simply add a mixing module to the returnair unit and bring outdoor air into this mixing module when conditions permit economizing. This configuration, sometimes called a “winterizer,” uses a combination of two different-sized airhandling units configured to allow the outdoor air to be introduced downstream of the cooling coil 34 CLCH-PRC022A-EN Application Considerations whenever the outdoor air is colder than 32°F (0°C). The smaller air-handling unit, sized for the minimum required ventilation airflow, contains filters and possibly a small preheat coil. This “winterizer” configuration removes the length and pressure drop associated with a preheat coil from the main air path, resulting in a shorter air-handling unit than if a conventional preheat coil, air-mixing baffles, or an energy-recovery device is used. And, since it adds no static pressure drop to the design of the supply fan, it has less impact on fan energy than these other approaches. However, the cost of the second, smaller air-handling unit is typically higher than an air-mixing baffles, and it requires a second, smaller set of filters that need to be replaced periodically. Figure 26. Horizontal split dehumidification indoor unit (SDU) Medium blank Outdoor air cooling coil Traq damper, filter mixing box Ventilation outdoor air Supply air Return air Fan Medium blank Return air Filter cooling coil Mixing box Economizing outdoor air Application Considerations: • Provides excellent humidity control in recirculating units, achieving SHR down to 0.4 without using new energy for reheat. • Can offer significantly lower operating costs and a low first cost. • Can be used in retrofits. • Uses standard components. • Does not require field-installed structural bracing. • Has a small foot print. • Is available in sizes 3-50, with the upper unit being sized between 20 to 50 percent of the lower unit. Dehumidifying with outdoor units can be achieved with an outdoor air pretreating SDU or by using two units. See Figure 27 and Figure 28. CLCH-PRC022A-EN 35 Application Considerations Figure 27. Outdoor air pre-treating split dehumidification unit Supply fan Filter mixing section Access Coil Filter mixing section (outdoor air only) Pre-treating coil Figure 28. Split dehumidification with outdoor units Supply fan Mixing section Coil Filter mixing section Discharge plenum Coil Filter mixing section Field-supplied ductwork 36 CLCH-PRC022A-EN Application Considerations Dehumidification with Hot-Water Heat-Recovery Coils Using waste condenser heat from the chiller or compressor is a simple way to provide dehumidification reheat. With this dehumidification strategy, a hot-water coil is installed after the active cooling coil. Hot water from the chiller—or from an auxiliary condenser on the chiller—is piped to this coil. Free reheat is available any time the chiller is on. Application Considerations: • Work with recirculating or 100-percent makeup-air units. • Provide excellent humidity control at any sensible-heat-ratio condition without using newenergy reheat. • Can reduce operating costs significantly. • Can be used in retrofits. • Use standard Trane components. • Provide proven, low-cost technology. Energy Recovery Trane air handlers offer high-performance solutions for airside energy recovery: • Total energy recovery wheels • Run-around coil loops • Air-to-Air plate frame heat exchangers These technologies transfer energy between the exhaust and outdoor air streams. Total energy recovery wheels transfer both sensible and latent energy between the air streams, while the coil loop transfers sensible energy. Energy-recovery arrangements: • Reduce operating costs. • Can reduce first cost by allowing downsizing of chillers and boilers. Energy-recovery systems can offer excellent energy savings when properly applied. Economic considerations must be carefully evaluated to determine the payback period of any energyrecovery system. For more information, refer to Trane applications engineering manual Air-to-Air Energy Recovery in HVAC Systems SYS-APM003-EN. Energy Recovery with a Total Energy Wheel This type of application is used to recover energy and moisture from the exhaust air stream. The wheel preheats and humidifies the supply air during the winter season and precools and dehumidifies the supply air during the summer season. Figure 29 and Figure 30 show an air handler arrangement with an exhaust fan, an economizer, and a total-energy wheel. CLCH-PRC022A-EN 37 Application Considerations Figure 29. Energy-recovery with a total energy wheel in indoor unit Figure 30. Energy-recovery with a total energy wheel in outdoor unit Exhaust air Outdoor air Return air Supply air As the return air enters the unit, a portion is recirculated through the return-air damper and the remainder goes through the wheel and is exhausted to maintain the required building pressure. Outdoor air enters an outdoor-air damper, then goes through the wheel and mixes with return air. During the economizing mode, the energy wheel is not used, and both wheel bypass dampers are open to allow up to 100-percent outdoor and exhaust airflow. If the energy wheel module is used in a VAV system or in a unit that supplies cold supply air, modulating the exhaust-air bypass damper at the wheel can prevent the air from overheating during onset of the heating mode. If frosting conditions exist, modulating the outdoor-air bypass damper at the wheel can prevent vapor in the exhaust air from freezing on the wheel. If bypass frost control is used as freeze protection for the wheel, add a blender module to adequately mix the outdoor and exhaust air streams. If bypass frost control is not used, add outdoor-air preheat or return-air reheat. 38 CLCH-PRC022A-EN Application Considerations Energy Recovery with Coil Runaround Loops Outdoor-air and exhaust-air coil runaround loops recover energy that would normally be exhausted. They precool the outdoor air during the cooling season and preheat the outdoor air during the heating season. With coil loops, the outdoor and exhaust air streams do not need to be adjacent. This provides design flexibility for building renovations and new construction—at a first cost that is often lower than other methods of energy recovery. Multiple exhaust and outdoor-air coils can be piped together with relative ease. Coil runaround loops use finned-tube hydronic coils in a closed loop to transfer energy. A typical runaround system is shown in Figure 31. The heat-transfer fluid pumped within the loop is usually an inhibited solution of ethylene glycol and water to avoid freeze up. Figure 31. Energy recovery with a runaround coil loop Application considerations: • Typical coil-loop effectiveness ranges from 45 to 65 percent with equal airflow and no condensation. Adhere to standard guidelines regarding coil construction, based on conditions. (See Trane catalog COIL-DS-1 and engineering bulletin COIL-EB-19 for more information.) • Coil performance and airside pressure drops can be determined using Trane selection tools. Coil loops offer complete separation of the air streams, thus eliminating any risk of crosscontamination. Loop components include the coils, a pump, expansion tank, and a three-way valve or variable-frequency drive (VFD). The expansion tank accommodates expansion and contraction of the internal fluid. The three-way valve or VFD modulates coil capacity. To prevent moisture in the exhaust air from freezing on the exhaust coil, the three-way valve can divert the warm fluid returning from the exhaust coil to the supply side of the coil. CLCH-PRC022A-EN 39 Application Considerations Energy Recovery with Air-to-Air Plate Frame Heat Exchangers This type of application is used to recover energy from the exhaust air stream using cross-flow aluminum plates. The air-to-air (ATA) plate frame heat exchanger preheats the supply air during the winter season and precools the supply air during the summer season. Figure 32 shows an air handler arrangement with an exhaust fan, economizer and ATA heat exchanger. As the return air enters the unit, a portion is recirculated through the return-air damper in the mixing box and the remainder goes through the air-to-air plate frame heat exchanger and is exhausted to maintain the required building pressure. Outdoor air enters an outdoor-air damper, then goes through the ATA heat exchanger and mixes with return air. During the economizing mode, the ATA heat exchanger is not used, and bypass dampers are open to allow up to 100-percent outdoor and exhaust airflow. The center bypass dampers can be selected for either the outside air or exhaust air path, but not both. If the ATA heat exchanger is used in a VAV system or in a unit that supplies cold supply air, modulating the exhaust-air bypass damper at the ATA heat exchanger can prevent the air from overheating during onset of the heating mode. If frosting conditions exist, frost avoidance dampers that block part of the outdoor air face of the exchangers close to minimize frosting potential. Frost control can also be achieved by modulating bypass dampers placed on the outside air side versus the exhaust side. If outside air bypass is used, freeze protection needs to be applied to any downstream hydronic coils. Figure 32. Energy recovery with air-to-air plate from heat exchanger 40 CLCH-PRC022A-EN Application Considerations Acoustics Designers are often challenged to select and arrange the air handler components so that the inlet, discharge and casing-radiated fan generated sound power levels help create a quiet space. To accomplish this, the designer must choose the right fan and determine whether additional unit attenuation is necessary. Choosing the Right Fan Obviously, the quieter the noise source (in this case, the fan), the less attenuation is needed along sound transmission paths. Selecting a quieter fan often increases the initial cost of the air handler, but can be a cost-effective system solution because it: • Reduces the need for path attenuation (e.g., silencers) by diminishing the sound level along all transmission paths • Reduces energy consumption (i.e., a fan is normally quietest when running at the most efficient point on its operating curve), providing operating cost savings to offset the initial cost. Trane acoustical tests have shown that a fan’s sound power (Lw) level depends on three factors: • Type/design • Operating point on the fan curve • Application requirements (e.g., critical octave band frequency) Figure 33 and Figure 34 compare the inlet and outlet sound power levels of four different fans. Together, these charts demonstrate that fan inlet sound is not equivalent to fan outlet sound. More importantly, they underscore the need to obtain accurate, AHRI 260 tested sound data from the manufacturer so that appropriate source and/or path attenuation methods can be applied. Trane gives designers a choice of many different fan types. See “Fans” section on page 52 for a summary of different fan application considerations and acoustical characteristics. Figure 33. Comparison of discharge sound power by fan type Figure 34. Comparison of inlet plus casing sound power by fan type Ducted Discharge Inlet+Casing 110 110 22.375" Housed FC (898 RPM, 10.9 BHP) 22.375" Housed FC (898 RPM, 10.9 BHP) 22" Housed AF (1642 RPM, 10.9 BHP) 22" Housed AF (1642 RPM, 10.9 BHP) 100 100 30" Direct-Drive Plenum (1282 RPM, 11.72 BHP) 90 80 NOTE: Sound power data is based on a draw-thru unit, front discharge, and 2 in. double wall perforated liner in the fan section. Fan delivery is 12,500 CFM at 4 in. wg Plenum Fan TSP. 70 60 63 125 250 500 1K Frequency, Hz CLCH-PRC022A-EN 2K 4K 32" Belt-Drive Plenum (1190 RPM, 12.1 BHP) Sound Power (Lw), dB Sound Power (Lw), dB 32" Belt-Drive Plenum (1190 RPM, 12.1 BHP) 30" Direct-Drive Plenum (1282 RPM, 11.72 BHP) 90 80 NOTE: Sound power data is based on a draw-thru unit, front discharge, and 2 in. double wall perforated liner in the fan section. Fan delivery is 12,500 CFM at 4 in. wg Plenum Fan 70 TSP. 60 8K 63 NOTE: 3.4 plus a 0.6 duct discharge loss = 4.0 TSP. 125 250 500 1K Frequency, Hz 2K 4K 8K NOTE: 3.4 plus a 0.6 duct discharge loss = 4.0 TSP. 41 Components and Options Performance air handlers adopt a ‘building-block’ approach to air-handling design. Each ‘building block’ or section contains one or more components that serve a specific purpose unique to each application. The required function, layout, and arrangement of the air-handling system determines which sections must be included for a particular application. Access/Blank and Turning Section Access or blank sections can provide access to internal components for cleaning, maintenance, and service or to promote proper airflow through the unit. A turning section is a blank section that alters the direction of airflow and reduces turbulence. It can also serve as an effective sound attenuator. When compared to a field-mounted, rectangular duct silencer, the turning section is less expensive to install, has a lower pressure drop, and provides more predictable performance. Perforated lining in the turning module attenuates midto high-frequency sound. Note: Only large and extra-large blank sections can be selected as turning sections. Blender Blender sections contain air-mixing baffles, or blenders, that rotate the passing air streams, boosting their velocity for improved mixing. It is usually placed immediately downstream of a mixing box section, and should always be positioned upstream of filters and coils. Figure 36 documents blender performance at a downstream coil entering air temperature of 55ºF and returnair temperatures of 70ºF and 75ºF. Application considerations: • Blender face velocity should be in the range of 500 to 2000 fpm for proper mixing. • When operated at temperatures within its design range, a blender may eliminate the need for preheat. • Space is required both upstream and downstream of the blender to allow complete air mixing. The standard design of the blender section satisfies these spacial requirements. • Select the mixing box such that the dampers are positioned at the top, back, or bottom when used with a blender. Figure 35. Use blenders for coil protection 42 Figure 36. Blender performance with 55ºF leaving air temperature CLCH-PRC022A-EN Components and Options CDQ™ Desiccant Dehumidification Wheel The CDQ wheel section (see Figure 37) is a used to enhance the dehumidification performance of a traditional cooling coil. It utilizes a Type III desiccant (activated alumina) chosen specifically for air-handling applications. The wheel is configured in series with a cooling coil, and requires only one air stream. The CDQ wheel rotates between the entering and leaving sides of the cooling coil. CDQ wheels are sized based on supply fan airflow. Unlike conventional equipment, the dew point of the supply air is not equal to the dew point of the air leaving the cooling coil. The required cooling coil capacity and air temperature leaving the coil are determined by the CDQ wheel performance. For more application information, refer to engineering bulletin CLCH-PRB020-EN. Figure 37. CDQ wheel Application Considerations: • Available in 14 unit sizes, ranging from 1000 to 25,000 cfm • Single wheel for unit sizes 3 to 50 with up to two wheels available per unit size • Can be applied in mixed air and dedicated outdoor air systems • Required cooling coil capacity is decreased when dehumidifying • Entering water temperatures to the coil can be increased • Section includes required space upstream and downstream of the wheel • Required access and doors in section • Variable effectiveness control using bypass dampers Additional dehumidification options CLCH-PRC022A-EN • Dual-path split dehumidification units (SDUs) • Low sensible-heat ratio coil selections • Series recovery supply air tempering 100 percent outdoor air units in conjunction with other Trane airside products 43 Components and Options Coils Figure 38. Coil with copper header Figure 39. Coil with cast iron header Coil Optimization The variety of Trane coil types, sizes, arrangements, and materials allows you to select a coil that is optimized for pressure drop and capacity requirements. Published coil performance is certified in accordance with AHRI Standard 410 and meets CRN (Canadian Registration Number) standards. Trane is at the leading edge of coil technology. Through extensive laboratory testing and numerous job-site installations, Trane has developed unique fin surfaces for its coil offerings. These enhanced fin surfaces have superior heat transfer characteristics and allow greater velocities of air to move through the cooling coil without causing moisture carryover. The industry is familiar with the 500-fpm limit through a cooling coil as a “rule of thumb” to safeguard against moisture carryover. However, some applications have tight dimensional constraints that require high coil face velocities. Trane fin designs extend this limit in excess of 625 fpm, depending upon air conditions, coil size, and coil-fin type, and spacing. Tested data for moisture carryover is incorporated in the Trane Official Product Selection System (TOPSS™). In cases where moisture carryover is possible, the TOPSS program alerts you to this fact with a moisture carryover warning. See “Face-Velocity Limits for Moisture Carryover,” p. 165 for moisture carryover curves. Coil options include but are not limited to the following: • Two- to eight-row, 1/2-inch OD (outside diameter) chilled water or refrigerant coils • Two- to 10-row, 5/8-inch OD chilled water or refrigerant coils • One- or two-row 5/8-inch OD hot water coils • Two-row, 1/2-inch OD hot water coils • One-row, 1-inch OD distributing-type steam coils • Half, full, and dual-serpentine, circuited water coils • Full face, split face, and intertwined circuited refrigerant coils A variety of fin surfaces are also available, with the following options: • Variable fin spacing on all fin types to fine-tune coil capacity and air-pressure drop • Aluminum Delta-Flo™ H and Prima-Flo™ H fins that maximize the heat transfer and moisture carryover limits of the coils • Aluminum Delta-Flo E and Prima-Flo E fins that minimize the coil air-pressure drop • Copper Prima-Flo™ fins for corrosion protection For additional information on coils, see Air Heating and Cooling Coils Quick Select COIL-PRC002-EN. 44 CLCH-PRC022A-EN Components and Options Drain Pans Figure 40. Extended drain pans for easy cleaning • Galvanized or stainless steel drain pans sloped in two directions to assure positive drainage helps prevent corrosion. • Drain pans that can extend beyond the cooling coil (see Figure 40) for periodic cleaning are standard options. • A variety of cooling coil fin options, including the high-efficiency H-fin design, are available. These fins allow for coil selections with face velocities in excess of 625 fpm without moisture carryover. • UV-C lights help preventing mold, bacteria and viruses from reproducing and also maintains or improve the system efficiency. Factory engineering and UV-C lights installation allows us to maximize the benefits of UV technology without jeopardizing the expected reliability and safety of the equipment. Electric Heat Figure 41. Typical 1-inch steam coil An electric heat coil is a relatively inexpensive first cost heating option compared to central plant boiler systems. Electric heat is a factory-installed, ULlisted option for unit sizes 3-66 draw-thru arrangements and 3-30 blow-thru arrangements in constant-volume or VAV applications. Application considerations: • Blow-thru arrangements require a minimum of a medium blank section between the supply fan and the electric heat section to ensure even air distribution across the electric heater. • A large access or discharge plenum section with a door for field-wiring access is required downstream of the electric heat section in a blow-thru arrangement. Integral Face-and-Bypass Coil Conventional preheat systems are subject to coil freeze-up, stratification, and air-volume variation. An integral face-and-bypass (IFB) coil is specifically designed to minimize these problems, alternating heating and bypass channels with face-and-bypass dampers before and after the coil. If heat is needed, both dampers modulate open; otherwise, they remain closed to prevent “coil wiping” on the leaving side of the coil and to avoid unwanted heat pickup. This design effectively provides good freeze protection, constant airflow, and uniformly mixed and unstratified air. The IFB coil comes as a complete package (including heating coil, linkage, and dampers), thus assuring maximum system reliability. The section uses horizontal coil-tube arrangements in unit sizes 6 to 40 and vertical coil-tube arrangements in unit sizes 50 to 100. These coils are capable of maintaining a constant heating discharge air temperature regardless of variations in entering air temperatures, with full steam pressure of hot water flow on the coils at all times. IFB coils consist of rectangular aluminum fin (.010-inch thick) elements, with 5/8-inch O.D..035 thick copper tubes completely enclosed in a 14-gauge galvanized steel casing, with 16gauge dampers. Dampers are arranged to completely enclose and isolate the heating coil elements when no temperature rise is required. Holes in the unit casing for supply and return connections are factory provided to facilitate field piping of the coils. Factory-mounted electronic actuators are available when specified. Figure 3 and Figure 4 list the sections required to house the integral face-and-bypass coil, and the downstream section required for proper air mixing space. External piping cabinets are required on CLCH-PRC022A-EN 45 Components and Options both sections. An optional access door can be added to the downstream section on units with an integral face-and-bypass coil. On units with a vertical integral face-and-bypass coil, an access door must be included in the downstream section, on the opposite side of the coil connection, to facilitate field piping of the supply and return connections on the coil. Table 3. Requirements for horizontal IFB coils Unit size 3 6 8 10 12 14 17 21 25 30 IFB section n/a Large Large Large Large Large Large Large Large Large Downstream section n/a Medium Medium Medium Medium Medium Table 4. Medium Medium Medium Medium 40 Medium Medium Requirements for vertical IFB Coils Unit size 50 57 66 80 100 IFB section MedLarge MedLarge MedLarge MedLarge MedLarge Downstream section 35 Med-Large Med-Large Medium Medium Medium Medium Medium External piping cabinets are required on both the IFB coil and the section immediately downstream of the coil. An optional access door can be added to the downstream section. On units with vertical IFB coils, an access door must be included in the downstream section to facilitate field piping of the supply and return connections on the coil. It is recommended that a factory selection of a coil be made based on scheduled performance prior to configuring a unit with an IFB coil, so as to determine whether the unit should be configured around an integral face-and-bypass coil or a vertical integral face-and-bypass coils. Dampers Face-and-Bypass Dampers Figure 42. Internal face-and-bypass damper Designed to divert airflow around a coil, the face-and-bypass damper can be used to control humidity or provide freeze protection for hydronic coils. Face-andbypass dampers are available in two module configurations, internal and external. Internal Face-and-Bypass Dampers Typically used immediately upstream of a modified-size (less than 100-percent airflow) coil, this arrangement enables temperature control while operating the preheat coil at full flow. The dampers modulate to bypass air around the heating coil when the outdoor air temperature is warm enough to preclude freezing. See Figure 42. Application considerations: 46 • To ensure full airflow coverage across downstream coil banks, provide extra distance after the modified-size coil section (see Table 5). • Consider the effect of reduced bypass area, higher velocities, and higher pressure drops when designing internal face-and-bypass configurations that require 100-percent bypass. External face-and-bypass dampers may be better suited for these configurations. CLCH-PRC022A-EN Components and Options Figure 43. Internal face-and-bypass configuration Fan Table 5. H Filter mixing box Unit size Distance between coils (inches) 3, 6 8, 10 12, 14 17 21 25-40 50 57, 66 80 100, 120 12.00 18.00 24.00 30.00 33.00 36.00 48.00 57.00 69.00 78.00 External face-and-bypass dampers perform the same function as their internal counterpart. However, they are used upstream of a full-face coil, and they route air around the coil through an external bypass duct. See Table 6 for recommended duct sizes that permit 100-percent bypass. Duct placement varies with each air handler arrangement. Ensure that the external bypass duct does not interfere with stacked modules. Use Table 6 in conjunction with Figure 44. Bypass airflow CLCH-PRC022A-EN Internal face-and-bypass External Face-and-Bypass Dampers L Table 6. Access or blank Recommended distance between coils to ensure full airflow coverage Figure 44. External bypass Fan Medium coil Recommended bypass duct sizes (inches) Unit size H W L 3 4 6 8 10 12 14 17 21 25 30 35 40 50 57 66 80 100 120 16.00 18.00 18.00 18.00 18.00 22.00 22.00 22.00 28.00 28.00 28.00 45.00 45.00 45.00 47.00 48.00 56.00 56.00 56.00 20.00 33.00 33.00 39.00 50.00 55.00 61.00 61.00 69.00 69.00 82.00 80.00 93.00 106.00 106.00 121.00 121.00 135.00 162.00 14.00 16.00 16.00 16.00 16.00 20.00 20.00 20.00 26.00 26.00 26.00 36.00 36.00 36.00 40.00 40.00 48.00 48.00 48.00 47 Components and Options Figure 45. Configuration A Table 7. Blank Size 3-12 Extended Medium 14-17 Medium- Large 21-120 Large External face-and-bypass with bypass between two coils Fan Medium coil Access or blank Small coil External face-andbypass Figure 46. Configuration B Table 8. External face-and-bypass with bypass between a coil and a top-discharge housed fan or a plenum fan Access or blank Fan Figure 47. Medium coil Small coil Table for Configuration A Unit Size Table for Configuration B Unit Size Blank Size 3-57 Extended Medium 66-120 Large External face-andbypass Configuration C Area of opening in fan module should be equal to “H” and “W” dimensions from Table 6. Fan H Vertical coil module 48 Coil External face-andbypass CLCH-PRC022A-EN Components and Options Traq™ Dampers and Low Flow Traq Dampers Figure 48. Traq dampers measure and The Trane AMCA 611-certified Traq™ airflow-monitoring solution control ventilation airflow. (seeFigure 48), allows direct measurement and control of outdoor and/or return airflow and is rated for a maximum leakage rate of 4 cfm/ft2 at 1 inch w.g. complying with ASHRAE Standard 90.1 maximum damper leakage. The lowflow Traq option can be used as a key part of a demand control ventilation strategy to help drive down energy costs. When applied as part of an Integrated Comfort™ system (ICS) with the Tracer Summit™ building automation system, ventilation airflow can be controlled dynamically and documented to verify compliance with ASHRAE Standard 62.1. (See Trane product catalog BASPRC001-EN for more information on Tracer Summit systems.) Factory-mounted and tested to reduce installation and startup costs, the Traq damper also requires significantly less straight duct than traditional airflow-monitoring stations and does not require upstream straightening vanes for proper operation that could become clogged with debris. The bell-mouth inlet of each damper guides air uniformly through a flow-sensing ring that accurately measures total and static pressure from 100 percent of nominal airflow down to 300 fpm through the damper. The damper assembly’s ventilation control module (VCM) produces a 2-to-10-Vdc signal that is proportional to airflow, recalibrates itself once every 60 seconds, and automatically adjusts for temperature variations. Depending on unit size and controls configurations Traq dampers can measure from 100 percent of design CFM, down to five percent design CFM. Application considerations: • The Traq damper mixing box requires only one duct diameter of straight inlet duct (as much as 80 percent less than other airflow monitoring techniques). • Connecting a Traq-damper-equipped air handler to a building automation system, such as a Tracer building management system, permits: – Dynamic calculation of the outdoor air needed to adequately ventilate a multispace VAV system and reset the outdoor-air setpoint accordingly to save energy. – Trend logs and custom reports to document compliance with ASHRAE Standard 62.1. Diffuser Figure 49. Diffusers provide even airflow. CLCH-PRC022A-EN A diffuser consists of pressure-equalizing baffles that are designed to provide even airflow across components downstream of a fan. The diffuser section is typically used immediately downstream of a centrifugal fan in a blow-thru filter, coil application. 49 Components and Options Discharge Plenum Figure 50. Discharge plenums can lessen low-frequency sound. Before leaving the air handler, supply air can be ducted to a discharge plenum section. The rapid air-stream expansion as it passes into the plenum reduces turbulence and creates an acoustical end reflection that dampens low-frequency sound. Perforated panels can be selected as an additional attenuation option. Two configurations enable supply-duct connections from any side: • Vertical-mounted plenum sections mount atop an adjacent section and can be increased 1.5 times or reduced 0.5 times to standard height minimizing field duct transitions. Openings can be factory- or field-cut. • Horizontal-mounted plenum sections mount on the front of an adjacent section. Openings can be factory- or field-cut. Vertical and horizontal discharge plenum openings can be tailored to the size, type and location to best fit the velocity and static pressure requirements, improving energy efficiency and sound. Round, rectangular, and bell mouth openings are all available. Economizer Figure 51. Outdoor economizer section An economizer section, for outdoor use only, provides an exhaust path for return air, allowing the system to provide natural, non-mechanical cooling when outdoor air conditions are suitable. Energy Recovery Increased ventilation airflow requires more energy to heat or cool and can significantly affect operating costs. Bringing in more fresh air when it is cold outside also increases the risk of coil freeze-up. Trane airside energy-recovery solutions address both energy consumption and coil protection by recovering heat from the exhaust air stream to pre-condition outdoor air entering the building.Trane has many factory-packaged energy-recovery solutions including: 50 • Total energy recovery wheels to recover both sensible and latent energy. See Figure 52. • Coil-runaround loops to recover sensible energy (see Figure 53). • Air-to-air plate frame heat exchangers recover sensible energy. CLCH-PRC022A-EN Components and Options Energy Wheels Figure 52. Energy wheel The energy wheel section is a total-energy-recovery device; it recovers both sensible and latent energy. It consists of a rotating wheel that contains heat exchange media surfaces. A desiccant material specifically designed for adsorption and desorption of water vapor is permanently bonded into the heat exchanger matrix. The wheel rotates between the outdoor- and return-air paths, whose air streams are counter-flow. Energy wheels are sized based on the ventilation air requirement and can be applied in a 100-percent-outdoor-air unit or a recirculation unit. Internal wheelbypass dampers vary the effectiveness of the wheel. For more application information on energy recovery, refer to these Trane applications manual SYS-APM003-EN. Application considerations: • Certified in accordance to AHRI Standard 1060 • Available in 18 sizes, depending on ventilation requirements ranging from 900 to 25,000 cfm • Single wheels for sizes 3-50 with up to seven wheels available per unit size • Greater than 70 percent total effectiveness at a pressure drop of 1 to 1.15 in. w.g. and nominal airflow through the wheel • Bypass dampers are standard for partial-flow energy wheel sections • Standard, built-in return damper for partial-flow, recirculating wheels for sizes 6-50 • Section includes required space upstream and downstream of the wheel • Required access and doors in the section • Variable effectiveness control using air bypass • Frost protection using an air bypass damper or a separate pre-heat module Coil Runaround Loop Figure 53. Coil-runaround loops recover sensible energy A runaround loop, used to recover sensible energy, consists of two finned-tube coils (air-to-water heat exchangers) piped together; one coil resides in the outdoor airstream and the other in the exhaust airstream. An expansion tank, pump, three-way temperature control valve and working fluid (usually an inhibited solution of ethylene glycol and water) complete the recovery system. Since the outdoor and exhaust airstreams need not be adjacent, the runaround loop provides design versatility well-suited to building renovations – at a lower first cost than other methods of energy recovery. Complete separation of the airstreams also eliminates the risk of cross-contamination. Application Considerations: • CLCH-PRC022A-EN Recovery is limited to sensible energy with effectiveness that typically ranges from 60-65 percent. 51 Components and Options • Together, the two finned-tube coils may contribute approximately 0.3 to 0.6 in. wg to system static pressure. Air-to-Air Plate Frame Heat Exchanger Figure 54. Air-to-air plate frame heat Air-to-air plate frame heat exchangers is a sensible-energy-recovery device. The exchanger consists of aluminum plates that are stamped into a dimpled or exchanger channeled shape. The plates are stacked on each other with the alternate edges crimped and sealed to prevent cross leakage. These can handle high pressure differentials, some up to 10 inches between the exhaust and outdoor air side. They also can handle higher temperatures and can be coated for corrosion protection. Application Considerations: • Certified in accordance to AHRI Standard 1060. • Three plate spacings available. • Bypass options available for variable effectiveness and frost prevention. • Up to 70 percent total effectiveness with close spacing. • Drain pans always required. • Can be used in a series arrangement for dehumidification. Fans Fan Choices An extensive array of fan types and options, including variable-frequency drives (VFDs) for modulation in variable-air-volume systems, lets you optimize the fan to best fit not only the airflow and static pressure requirements, but also the acoustical, efficiency, and discharge requirements. Figure 55. Trane offers a wide variety Fan types include: of fan choices • Double-width/double-inlet (DWDI) centrifugal fans with front, top, or bottom discharges in the following available types: – Forward-curved (FC) – Backward-curved (BC) – Airfoil (AF) • Single-width/single-inlet (SWSI) plenum fans with multiple or single discharges on the front, top, bottom, or sides of the section – Direct-drive plenum fans – Belt-drive plenum fans Plenum fan openings can be tailored to the size, type and location to best fit your velocity and static pressure requirements improving energy and sound. Round, rectangular, and bell mouth openings are all available. Each fan is rated in accordance with Standard 430 of the Air Conditioning Heating and Refrigeration Institute (AHRI) and all DWDI fans are AHRI Standard 430certified to assure published performance. 52 CLCH-PRC022A-EN Components and Options Table 9 summarizes and compares the characteristics and application considerations of these fans. When evaluating the merits of each fan type for a given application, consider the volumetric rate of airflow, static pressure, required sound characteristics, and space. Table 9. Fan summary information Fan type FC Fan Centrifugal, housed Backward-curved (BC) Fan Centrifugal, housed AF Fan Centrifugal, housed Plenum Fan Unhoused Inlet Airflow direction Double Double Double Single Radial Radial Radial Pressurized, all directions Medium to high Low to medium High (4 to 8 in. wg) High (4 to 8 in. wg) Optimal pressure range (2 to 8 in. wg) (0 to 5 in. wg) First cost (relative) Low Medium Medium High Operating cost (relative) Medium Medium-high Medium-high Medium Typical speed range 400–1,600 rpm 1,000–2,600 rpm 1,000–2,600 rpm 600–1,600 rpm Blade shape Curved Curved Airfoil Airfoil Significant air turbulence that Significant air turbulence; Significant air turbulence; Discharge sound but higher Acoustical characteristics quickly abates; little blade- strong blade tones in 250-Hz strong blade tones in 250-Hz inlet noise1 tone noise octave band octave band Avoid using inlet vanes; use Avoid using inlet vanes; use Add a discharge plenum or Suggested source discharge plenums and/or Add a discharge plenum discharge plenums and/or outlet/inlet silencer attenuation silencers silencers Direct upstream space required in draw-thru None None None Medium module arrangements Direct downstream space Medium blank or diffuser Medium blank or diffuser Medium blank or diffuser Medium blank module required in blow-thru module module module arrangements Multiple-duct arrangement, When to use? Low-pressure applications High-pressure applications High-pressure applications blow-thru applications2 Kt loss, abrupt discharge3 1.80 1.00 1.00 n/a Note: 1. Add duct takeoff losses from the plenum fan module to external static pressure; see Trane fan performance catalog CLCH-PRC008-EN for details. 2. Same as Note 1; the uniform discharge velocity of the plenum fan may eliminate the need for turns in supply-air ductwork and diffusers, suiting it for installations with limited equipment room space. 3. In draw-thru applications, fan curves assume three diameters of straight duct downstream of the fan. Refer to AMCA 201-02, Fans and Systems, for more information when this assumption is not valid. To verify that fan performance will satisfy design requirements, use the TOPSS selection program. The AHRI Standard 430-certified fan curves include the fan section casing effect. TOPSS also takes into account ductwork connections, air density, fan and motor heat, drive losses, and use of highperformance (MERV 11 and higher) filters affect fan performance. Constant Volume vs. VAV Systems Depending on the fan-control method used, the fan can provide either a constant or variable volume of supply air. In a constant-volume system, the fan delivers a consistent amount of air and cooling and heating devices adjust the air temperature for occupant comfort. Because the fan runs at constant horsepower under all load conditions, system operating costs are higher than those of a VAV system. A VAV system provides occupant comfort by delivering a modulated amount of constanttemperature air. Usually, supply-duct static pressure determines how much air the fan provides. Varying fan horsepower with building load can offer substantial energy savings and do a better job of controlling space humidity. Fan modulation is accomplished with a variable-frequency drive (VFD) that adjusts fan speed and airflow by varying motor speed. VFD modulation is quiet and energy efficient; it can also prolong the life of the fan motor by “soft starting” it. CLCH-PRC022A-EN 53 Components and Options Airflow Measuring Systems Figure 56. Piezometer ring measures inlet air flow. A fan inlet airflow measuring system with a piezometer ring is also available on many centrifugal and plenum fans. Each system comes with a differential pressure transmitter (see Figure 56). The piezometer ring is connected to the LO port of the transmitter and the reference pressure point is connected to the HI port of the transmitter. Filtration and Air Cleaning Effectively controlling particulate and gaseous contaminants by reducing their concentrations or removing them from the air stream altogether is key to good IAQ. That necessitates proper filter selection. Filtration and cleaning options include: • Pleated media (MERV 8 to 14 based on ASHRAE Standard 52.2) • Bag or cartridge filters (MERV 11 to 15 based on ASHRAE Standard 52.2) • HEPA filters (MERV 17 based on ASHRAE Standard 52.2) • Trane Catalytic Air Cleaners (TCACS) reduce microorganisms to a non-viable state • Antimicrobial treatments for filters inhibiting microbial growth (MERV 7 based on ASHRAE Standard 52.2) Filtration Options Figure 57. Bag filter sectionentering side Figure 58. Bag filter section leaving side Figure 59. HEPA filter section Air handlers can be equipped with a variety of filtration options, all tested in accordance with ASHRAE Standard 52.2. The continuous operating range of both the high-efficiency filters and the disposable prefilter is typically 0ºF to 150ºF, but can be as high as 200ºF. Available filters and minimum efficiency reporting values (MERV) are: 54 CLCH-PRC022A-EN Components and Options • Two-inch permanent-MERV 2 • Two-inch disposable-MERV 5 • Two-inch and four-inch pleated media-MERV 8-14 • Eighteen-inch and 30-inch bag or 12-inch cartridge filters-MERV 11-15 • Two-inch and four-inch antimicrobial-treated filters-MERV 7 • HEPA • Multiple side-loading and front-loading filter options Application considerations: • Higher filter efficiencies cost more, but provide cleaner air and better system performance. National, state, and local codes may also specify filter performance. • Operating resistance to airflow (i.e. pressure drops). Filter resistance and first cost may increase with efficiency. • High filtration efficiencies sometimes require more space, which lowers velocity, and may enlarge the air handler footprint. • A high degree of filtration can lower cleaning costs in the occupied space. • Exceeding the face velocity limit of the filter increases its resistance (as well as fan energy consumption) and necessitates more frequent maintenance or replacement. • Exercise special care to avoid moisture carryover whenever final filters are used. Never place a blow-thru final filter section directly downstream of a cooling coil without providing an intervening source of reheat (such as fan motor). Tests have shown that certain entering-coil conditions can create water vapor that will collect on the final filter. The only known solution for this intermittent application issue is two degrees of reheat. • Treating filter media with an antimicrobial coating can reduce the likelihood of microbial contamination. Trane coated pleated media filters can be treated with an antimicrobial coating. • Install bag filters with the pleats vertical to the floor of the unit. • Provide easy access to encourage regular filter maintenance. • High-efficiency filters and disposable pre-filters may be operated near 100 percent relative humidity; however, they may not come in direct contact with water droplets. • Keep filters dry. Air Cleaning Options Figure 60. TCACS uses three air cleaning technologies. The Trane Catalytic Air Cleaning System (TCACS) is a factory engineered and installed combination of three air cleaning technologies: MERV 13 particle collection, high-intensity UVc light, and photo-catalytic oxidation (PCO). The high efficiency MERV 13 filters are very good at removing small, respirable particles from the airstream. The UVc/PCO combination reduces volatile organic compounds (VOC’s) through photocatalytic oxidation without the creation of ozone or by-products. The combination of the three technologies also has a signification capability to reduce the spread of airborne biological containments including viruses, bacteria and fungi/mold. The UV energy in the TCACS creates hydroxyl radicals on the surface of the titanium dioxide which oxidizes contaminants that they contact. All reactions occur within the air cleaner and no by-products leave the unit. The factory installed system comes complete with appropriate safety mechanisms protecting the owners and operators of the system. These safeties include an external disconnect with lock-out/tag-out capabilities, door interlock switches, and UVc viewport. CLCH-PRC022A-EN 55 Components and Options Gas Heat Figure 61. Gas heat module Gas heat can be an economical source of heat when compared to traditional heat sources such as central plant boilers with hot water or steam coils installed inside air handlers, or electric resistance heating installed inside air handlers. Gas heat can be a good heating option for any of the following applications: • Climates and applications with large heat loads • Applications with high outside air requirements to comply with ASHRAE Standard 62 • Buildings without a central boiler plant • Remote locations where boiler capacity or water piping expense is prohibitive • Areas with relatively inexpensive natural gas or expensive electricity Application considerations: • Gas heater must be applied in a blow-thru configuration to insure that combustion gases will not enter the airstream due to the positive static pressure. • Maximum discharge air temperature is 101° F. • When reducing airflow, the control system should not allow the temperature rise through the gas heat section to exceed the nominal at full airflow. • On high altitude applications, derate the heating capacity (MBh) by 4 percent for every 1,000 feet over 2,000 feet. Humidifier Figure 62. Humidifier section ASHRAE Standard 62.1 suggests maintaining a relative humidity of no less than 30 percent to provide a comfortable, healthy indoor environment. The humidifier uses low-pressure steam distributors to add moisture to the air. This can be accomplished by using either building stream or an atmospheric steam generator. It includes accessories such as valves, strainers, and traps. Factory mounting within the air handler lowers the installed cost of the humidifier and keeps moisture out of the supply duct. Application considerations: 56 • Airflow through the humidifier must be horizontal and of relatively uniform velocity (400 to 700 fpm). • Do not locate the humidifier upstream of filters, gas heat, electric heat, or active cooling coils. • Blow-thru applications with housed fans require at least a four-row coil between the fan and humidifier modules. The diffuser alone is unacceptable. • To prevent condensate formation, the relative humidity leaving the humidifier should not exceed 83 percent. Contact your local Trane sales engineer for application-specific guidance. • The required dispersion distance is designed into the humidifier section. • Vertical airflow turning immediately upstream and downstream of the humidifier section requires a large turning section. CLCH-PRC022A-EN Components and Options Inlet Hood Inlet hoods include a moisture eliminator. Eliminator face velocities below 950 fpm will avoid pulling water through the eliminator fins and into the unit. It is possible for the moisture to be carried over into the unit when elimination face velocities are above 950 fpm. OA Inlet Hood Requirements Many specification require that there be a minimum distance between the point that outside air enters an air handler and the roof of a building. This distance is to minimize the possible introduction of contaminants into the conditioned air. ASHRAE 62 recommends that there be at least 9 inches (or 8 inches above maximum snow depth) separation from the roof to the outside air intake, however, some specifications, specifically for units in the health care industry require at least 36 inches of separation distance. When configuring and air handler, ensure that the unit in conjunction with a roof curb will meet the specifications requirements on separation distance. Mixing Box and Economizer Figure 63. Mixing Box A mixing box section typically combines the incoming outdoor air with recirculated return air collected from the occupied space. It is commonly included in an air handler design to control this mixture. When equipped with an optional Traq damper, the mixing box module permits direct measurement of outdoor airflow to assure compliance with ASHRAE Standard 62.1. Application considerations: • The Traq damper mixing box requires only one duct diameter of straight inlet duct (as much as 80 percent less than other airflow monitoring techniques). • Connecting a Traq-damper-equipped air handler to a building automation system, such as a Tracer building management system, permits: – Dynamic calculation of the outdoor air needed to adequately ventilate a multispace VAV system and reset the outdoor-air setpoint accordingly to save energy. – Trend logs and custom reports to document compliance with ASHRAE Standard 62.1. CLCH-PRC022A-EN • For indoor units, an additional mixing box can be used as an economizer to provide an exhaust path for return air, allowing the main mixing box to provide natural, non-mechanical cooling when outdoor air conditions are suitable. • For outdoor units, and economizer section can be used to provide a path for outside air, return air and exhaust air in a single section. • Use freeze protection for coils downstream of the mixing box when incoming outdoor air is below 35ºF (see “Protect Coils from Freezing,” p. 20). 57 Components and Options Multizone The multizone module consists of a cooling coil, heating coil, and dampers with multiple zones. It can be split into either two decks or three decks, each with a separate air stream. The “cold” deck cools one air stream and the “hot” deck heats another air stream. A third deck can be used for bypass air. The damper then mixes these air streams to achieve a certain mixed-air temperature. The damper is divided into segments so that one AHU can deliver multiple supply air temperatures. Baffles ensure equal pressure drops through each deck of the unit. The multizone module is always used in a blow-thru arrangement and is typically placed directly downstream of the supply fan. Note: The number of zones that one multizone AHU can supply varies by unit size. Be aware that ASHRAE Standard 90.1 does not allow for multizone configurations without bypass for new construction. Silencers Figure 64. Sound attenuators used in low NC level applications Controlling noise at its source is the most cost-effective solution for providing quiet comfort in the space. Source attenuation can eliminate the need for ductmounted silencers and thereby lower fan operating costs. The key to a quiet design is to know which options and layouts have a sound source that achieves the target noise criterion (NC) level when reduced by space attenuation. It all starts with accurate, tested sound data, and Trane has the most complete sound power data in the industry. The design process involves predicting the unit sound power and projecting it into the space, then optimizing the path attenuation (ductwork, ceilings) and the unit sound (fans, plenums) to get the lowest cost system that meets the requirements. Designing the right unit is a matter of experience and solid acoustical data. Obviously, the quieter the sound source, the less path attenuation is needed in the sound paths. Minimizing the sound source, using a quieter fan, or using more source attenuation increases the initial cost of the air handler, but is generally offset by significant path-reduction cost savings. 58 CLCH-PRC022A-EN General Data This section includes summary information per unit size, including section dimensions and weights, coil availability, filter areas and sizes, fan section weights and application data, and damper areas. Note: For specific dimensional and weight information, refer to the unit submittals. The dimensions and weights in this manual are approximate. Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. Unit Size 3 Table 10. Section dimensions (inches) and weights (pounds) - unit size 3 Nominal airflow 1500 Airflow at 625 fpm 2169 Height - indoor unit (in.) 29.00 Width (in.) 31.50 Height - outdoor unit (in.) includes base drip lip 36.25 Weight add for outdoor unit (lbs./in. of unit length) Section type 1.66 Length (in.) Weight (lb.) 10.00 48.05 Access or blank -Small horizontal -Medium horizontal 14.00 59.91 -Extended-medium horizontal 19.00 74.73 -Medium-large horizontal 24.50 121.60 -Large horizontal or turning 34.00 137.75 -Extra-large horizontal or turning 36.00 143.68 -Ducted inlet or ducted outlet section 10.00 48.10 Blender 19.00 94.86 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section 52.00 495.00 -Small horizontal (with 4-row UW) 10.00 116.10 -Medium horizontal (with 8-row UW) 14.00 168.65 -Extended-medium horizontal (with 8-row UW) 19.00 185.58 Coils -Medium-large horizontal (with 10-row W) 24.50 270.61 -Large horizontal or vertical (with 10-row W) 34.00 302.77 -Electric Heat Coil 36.00 295.00 n/a n/a Controls section (includes largest available VFD) 28.50 184.00 Diffuser 10.00 45.70 -Horizontal 34.00 135.40 -Vertical 36.00 159.90 n/a n/a -Integral-face-and-bypass (IFB) coil Discharge plenum Energy Wheel Face-and-Bypass Dampers CLCH-PRC022A-EN -Face-and-bypass 19.00 105.60 -External face-and-bypass 19.00 122.68 -Internal face-and-bypass or face damper only 19.00 107.95 59 General Data Table 10. Section dimensions (inches) and weights (pounds) - unit size 3 Fan Length (in.) Weight (lb.) -Belt-drive plenum (BDP) fan with motor 36.00 397.87 -Housed fan FC with motor 36.00 368.77 -Housed AF/BC fans with motor 36.00 378.87 -Direct-drive plenum fan with motor 36.00 373.16 -Side load 2-in. angled 24.50 134.55 -Side load 4-in. angled 24.50 141.89 -Side load cartridge 12-in. or short bag 18-in. 24.50 125.03 -Side load 2-in. flat 14.00 70.27 -Side load 4-in. flat 14.00 81.56 Filters Filters -Side load 2-in. and 4-in. combination flat 19.00 100.62 -Long bag 30-in. 36.00 159.54 -Front-load HEPA 40.00 240.36 -Front-load cartridge, 2-inch and 4-inch 40.00 215.15 -Front-load short bag 45.00 222.35 n/a n/a -Building Steam 14.00 125.00 -Atmospheric 14.00 127.00 -with angled filters 34.00 137.75 -with front/back Traq and top Traq dampers 36.00 191.06 - reduced length mixing box with side/top/back/bottom airfoil damper 23.40 131.80 n/a n/a -3 feet 38.00 198.00 -5 feet 62.00 308.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 334.73 UV light 14.00 76.02 Gas heat Humidifier Mixing box Multizone Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 46.00 187.00 -with airfoil damper and one side Traq damper 46.00 204.00 Exhaust damper section 19.00 93.30 - Back inlet hood - airfoil and Traq 22.25 22.00 - Side inlet hood - airfoil and Traq 20.00 17.00 - Exhaust hood - airfoil 20.00 12.00 - Economizer inlet hood 45.50 41.00 Hoods Pipe Cabinets 60 15 in. long - 24-in. depth 15.00 77.00 15 in. long - 36-in. depth 15.00 104.00 15 in. long - 48-in. depth 15.00 132.00 24 in. long - 24-in. depth 24.00 91.00 24 in. long - 36-in. depth 24.00 122.00 24 in. long - 48-in. depth 24.00 153.00 CLCH-PRC022A-EN General Data Table 10. Section dimensions (inches) and weights (pounds) - unit size 3 Pipe Cabinets Length (in.) Weight (lb.) 48 in. long - 24-in. depth 48.00 130.00 48 in. long - 36-in. depth 48.00 169.00 48 in. long - 48-in. depth 48.00 208.00 207.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 263.00 96 in. long - 48-in. depth 96.00 319.00 Table 11. Filter data for unit size 3 Filter Type Area ft² Qty–Size (in.) Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 3.47 1 - 20x25 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 5.56 2 - 16x25 Side load bag or cartridge 3.33 1 - 20x24 Front load bag or cartridge 2.00 1 - 12x24 Front load HEPA 2.00 1 - 12x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 12. Coil availability - unit size 3 Section Type 1/2-in Unit Coils 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils Small 2-4 rows 1-2 rows Medium 2–8 rows 1–4 rows Extended-medium 2–8 rows 1–8 rows Medium-large 2-8 rows 1-10 rows -with access 2–6 rows 1–3 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–6 rows Large vertical 2-8 rows 1–6 rows -with access 2–8 rows 1–4 rows Table 13. Coil data for unit size 3 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 2, 4, 6, 8 Aluminum 2.92 1–20 × 21 1, 2, 3, 4, 6, 8, 10 Aluminum or Copper 2.50 1–18 × 20 6, 8, 10 Aluminum or Copper 2.38 1–18 × 19 1 Aluminum or Copper 2.50 1–18 × 20 2, 4, 6, 8 Aluminum 1.74 1–12.50 × 20 1, 2, 3, 4, 6, 8, 10 Aluminum or Copper 1.67 1–12 × 20 1 Aluminum or Copper 1.67 1–12 × 20 1/2-inch unit coils -UA,UW, UF 5/8-inch unit coils -W, 5A, 5W, D1, TT, P2, P4, P8 -WD, D2 1-inch unit coil -NS 1/2-inch modified coil -WL 5/8-inch modified coils -W, 5A, 5W, D1, TT, P2, P4 1-inch modified coil -NS CLCH-PRC022A-EN 61 General Data Table 14. Fan data for unit size 3 Housed Fans Low Pressure High Pressure Size/type 9-in FC 9-6-in FC 9-4-in FC 9-in BC 9-in FC 9-6-in FC 9-4-in FC Fan name 9FA 5FA 4FA 9BA 9FB 5FB 4FB 9-in BC 9BB Max TSP/rpm 4/2250 4.5/2250 4.5/2250 6.5/4375 5/2900 6.5/2900 7/2900 8/5000 ODP NEMA Prem motor hp range 0.75-5 0.75-3 0.75-3 0.75-3 0.75-3 0.75-3 0.75-3 0.75-3 Outlet area (ft²) 0.85 0.60 0.50 0.85 0.85 0.60 0.50 0.85 Bearing/Shaft size (in.) 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 Belt-drive Plenum Fans Direct-Drive Plenum Fans High Pressure High Pressure 10.5-in. AF 10.5-in. AF Nominal Width Extended Width Size/type 11-in BC Fan name 11PB 10-in BC 10PB 10NF Max TSP/rpm 9/4735 8/5200 5195 5195 ODP NEMA Prem motor hp range 0.75-5 0.75-3 1-5 1.5-5 Outlet area (ft²) n/a n/a Bearing/Shaft size (in.) n/a n/a 10NW Unit Size 4 Table 15. Section dimensions (inches) and weights (pounds) - unit size 4 Nominal airflow 2000 Airflow at 625 fpm 3475 Height - indoor unit (in.) 29.00 Width (in.) 44.00 Height - outdoor unit (in.) includes base drip lip 36.38 Weight add for outdoor unit (lbs./in. of unit length) Section type 1.91 Length (in.) Weight (lb.) 10.00 57.43 Access or blank -Small horizontal -Medium horizontal 14.00 71.18 -Extended-medium horizontal 19.00 88.37 -Medium-large horizontal 24.50 107.28 -Large horizontal or turning 34.00 164.85 -Extra-large horizontal or turning 41.00 188.92 -Ducted inlet or ducted outlet section 10.00 57.40 Blender 24.50 132.71 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section 52.00 651.00 -Small horizontal (with 4-row UW) 10.00 148.55 -Medium horizontal (with 8-row UW) 14.00 220.23 239.53 Coils 62 -Extended-medium horizontal (with 8-row UW) 19.00 -Medium-large horizontal (with 10-row W) 24.50 359.79 -Large horizontal or vertical (with 10-row W) 34.00 396.45 -Electric Heat Coil 41.00 364.00 -Integral-face-and-bypass (IFB) coil --Less than 4 rows 26.50 355.20 --4 rows 43.00 543.54 CLCH-PRC022A-EN General Data Table 15. Section dimensions (inches) and weights (pounds) - unit size 4 Section type Length (in.) Weight (lb.) Controls section (includes largest available VFD) 28.50 208.00 Diffuser 10.00 55.08 -Horizontal 34.00 162.50 -Vertical 41.00 211.48 Energy Wheel 52.00 609.00 Discharge plenum Face-and-Bypass Dampers -Face-and-bypass 19.00 129.06 -External face-and-bypass 19.00 155.15 -Internal face-and-bypass or face damper only 19.00 140.46 -Belt-drive plenum (BDP) fan with motor 41.00 538.34 -Housed fan FC with motor 41.00 449.75 -Housed AF/BC fans with motor 41.00 467.35 -Direct-drive plenum fan with motor 41.00 516.35 -Side load 2-in. angled 24.50 163.83 -Side load 4-in. angled 24.50 176.87 -Side load cartridge 12-in. or short bag 18-in. 24.50 159.79 Fan Filters Filters -Side load 2-in. flat 14.00 86.53 -Side load 4-in. flat 14.00 104.62 -Side load 2-in. and 4-in. combination flat 19.00 128.19 203.31 -Long bag 30-in. 41.00 -Front-load HEPA 40.00 262.50 -Front-load cartridge 40.00 237.79 -Front-load short bag 45.00 246.75 n/a n/a -Building Steam 14.00 146.00 -Atmospheric 14.00 168.00 -with angled filters 34.00 164.85 -with front/back Traq and top Traq dampers 41.00 247.07 - reduced length mixing box with side/top/back/bottom airfoil damper 23.40 158.30 n/a n/a -3 feet 38.00 256.00 -5 feet 62.00 391.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 367.14 UV light 14.00 93.64 Gas heat Humidifier Mixing box Multizone Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer CLCH-PRC022A-EN -with airfoil dampers 49.00 231.00 -with airfoil damper and one side Traq damper 49.00 247.00 Exhaust damper section 19.00 113.30 63 General Data Table 15. Section dimensions (inches) and weights (pounds) - unit size 4 Hoods Length (in.) Weight (lb.) - Back inlet hood - airfoil and Traq 44.00 45.00 - Side inlet hood - airfoil and Traq 20.00 17.00 - Exhaust hood - airfoil 20.00 12.00 - Economizer inlet hood 49.00 37.00 Pipe Cabinets 15 in. long - 24-in. depth 15.00 77.00 15 in. long - 36-in. depth 15.00 104.00 15 in. long - 48-in. depth 15.00 132.00 24 in. long - 24-in. depth 24.00 91.00 24 in. long - 36-in. depth 24.00 122.00 24 in. long - 48-in. depth 24.00 153.00 130.00 48 in. long - 24-in. depth 48.00 48 in. long - 36-in. depth 48.00 169.00 48 in. long - 48-in. depth 48.00 208.00 207.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 263.00 96 in. long - 48-in. depth 96.00 319.00 Table 16. Filter data for unit size 4 Filter Type Area ft² Qty–Size (in.) Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 5.56 2 - 20x20 Angled (2-in. or 4-in.) pleated, permanent, throwaway media 8.89 4 - 16x20 Side load bag or cartridge 5.56 2 - 20x20 Front load bag or cartridge 2.00 1 - 12x24 Front load HEPA 2.00 1 - 12x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 17. Coil availability - unit size 4 Section Type 64 1/2-in Unit Coils 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils Small 2-4 rows 1-2 rows Medium 2–8 rows 1–4 rows Extended-medium 2–8 rows 1–8 rows Medium-large 2-8 rows 1-10 rows -with access 2–6 rows 1–3 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–6 rows Large vertical 2-8 rows 1–6 rows -with access 2–8 rows 1–4 rows CLCH-PRC022A-EN General Data Table 18. Coil data for unit size 4 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1, 2, 4, 6, 8 Aluminum 4.51 1–20 × 32.50 1, 2, 3, 4, 6, 8, 10 Aluminum or Copper 4.00 1–18 × 32 6, 8, 10 Aluminum or Copper 3.88 1–18 × 31 1 Aluminum or Copper 4.00 1–18 × 32 1, 2, 4, 6, 8 Aluminum 2.78 1–12.50 × 32 1, 2, 3, 4, 6, 8, 10 Aluminum or Copper 2.67 1–12 × 32 1 Aluminum or Copper 2.67 1–12 × 32 1/2-inch unit coils -UA, UW, UF 5/8-inch unit coils -W, 5A, 5W, D1, TT, P2, P4, P8 -WD, D2 1-inch unit coil -NS 1/2-inch modified coil -WL 5/8-inch modified coils -W, 5A, 5W, D1, TT, P2, P4 1-inch modified coil -NS Table 19. Fan data for unit size 4 Housed Fans Low Pressure Size/type Fan name High Pressure 10-in. FC 9-in. FC 9-6-in. FC 10-in. BC 9-in. BC 10-in. FC 9-in. FC 9-6 in. FC 10-in. BC 9-in. BC 10FA 9FA 5FA 10BA 9BA 10FB 9FB 5FB 10BB 9BB 4.5/2100 4/2250 4.5/2250 5/4070 6/4375 6/2525 6/2900 6.5/2900 8/4650 8/5000 0.75-5 0.75-3 0.75-3 0.75-3 0.75-3 0.75-5 0.75-5 0.75-5 0.75-5 0.75-5 Outlet area (ft²) 1.04 0.84 0.60 1.04 0.85 1.04 0.84 0.60 1.03 0.85 Bearing/Shaft size (in.) 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 Max TSP/rpm ODP NEMA Premium motor hp range Belt-drive Plenum Fans Low Pressure Size/type Fan name 12-in. AF Direct-Drive Plenum Fans High Pressure 12-in. AF 11-in. BC High Pressure 13.5-in AF Reduced Width 13.5-in AF Nominal Width 12PA 12PB 11PB 13NR 13NF Max TSP/rpm 7/4130 7.5/4500 9/4735 4038 4038 ODP NEMA Premium motor hp range 0.75-5 0.75-7.5 0.75-5 1.5-7.5 1.5-7.5 Outlet area (ft²) n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 1.00 1.19 0.75 n/a n/a CLCH-PRC022A-EN 65 General Data Unit Size 6 Table 20. Section dimensions (inches) and weights (pounds) - unit size 6 Nominal airflow 3000 Airflow at 625 fpm 4338 Height - indoor unit (in.) 35.25 Width (in.) 44.00 Height - outdoor unit (in.) includes base drip lip 42.63 Weight add for outdoor unit (lbs./in. of unit length) Section type 1.91 Length (in.) Weight (lb.) -Small horizontal 10.00 60.55 -Medium horizontal 14.00 75.25 -Extended-medium horizontal 19.00 93.62 Access or blank5 -Medium-large horizontal 24.50 113.84 -Large horizontal or turning 34.00 179.46 -Extra-large horizontal or turning 41.00 205.18 -Ducted inlet or ducted outlet section 10.00 60.50 Blender 24.50 146.30 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section 52.00 694.00 -Small horizontal (with 4-row UW) 10.00 174.35 -Medium horizontal (with 8-row UW) 14.00 265.58 -Extended-medium horizontal (with 8-row UW) 19.00 286.06 Coils -Medium-large horizontal (with 10-row W) 24.50 433.08 -Large horizontal or vertical (with 10-row W) 34.00 471.99 -Electric Heat Coil 41.00 413.00 -Integral-face-and-bypass (IFB) coil --Less than 4 rows 26.50 367.21 --4 rows 43.00 560.74 Controls section (includes largest available VFD) 28.50 253.00 Diffuser 10.00 58.20 -Horizontal 34.00 177.11 -Vertical 41.00 233.54 Energy Wheel 52.00 663.00 -Face-and-bypass 19.00 141.70 -External face-and-bypass 19.00 167.79 -Internal face-and-bypass or face damper only 19.00 149.91 -Belt-drive plenum (BDP) fan with motor 41.00 631.36 -Housed fan FC with motor 41.00 544.28 -Housed AF/BC fans with motor 41.00 574.68 -Direct-drive plenum fan with motor 41.00 535.05 Discharge plenum Face-and-Bypass Dampers Fan 66 CLCH-PRC022A-EN General Data Table 20. Section dimensions (inches) and weights (pounds) - unit size 6 Filters Length (in.) Weight (lb.) -Side load 2-in. angled 24.50 175.66 -Side load 4-in. angled 24.50 192.86 -Side load cartridge 12-in. or short bag 18-in. 24.50 176.46 -Side load 2-in. flat 14.00 91.98 114.08 -Side load 4-in. flat 14.00 -Side load 2-in. and 4-in. combination flat 19.00 139.09 -Long bag 30-in. 41.00 224.00 -Front-load HEPA 40.00 346.00 -Front-load cartridge 40.00 286.00 -Front-load short bag 45.00 280.00 - 200 MBH 57.00 752.90 - 300 MBH 73.00 901.30 -Building Steam 14.00 165.00 -Atmospheric 14.00 178.00 -with angled filters 34.00 179.46 -with front/back Traq and top Traq dampers 41.00 272.06 - reduced length mixing box with side/top/back/bottom airfoil damper 23.40 177.90 - 3-deck vertical discharge 61.00 1125.00 - 2-deck vertical discharge 61.00 763.00 - 3-deck horizontal discharge 52.00 1031.00 - 2-deck horizontal discharge 52.00 701.00 -3 feet 38.00 286.00 -5 feet 62.00 436.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 389.00 UV light 14.00 98.69 Gas heat Humidifier Mixing box Multizone Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 50.00 256.00 -with airfoil damper and one side Traq damper 50.00 271.00 Exhaust damper section 19.00 124.30 - Back inlet hood - airfoil and Traq 44.00 47.00 - Side inlet hood - airfoil and Traq 20.00 22.00 - Exhaust hood - airfoil 20.00 16.00 - Economizer inlet hood 49.50 45.00 Hoods Pipe Cabinets 15 in. long - 24-in. depth CLCH-PRC022A-EN 15 in. long - 36-in. depth 15.00 116.00 15 in. long - 48-in. depth 15.00 146.00 101.00 24 in. long - 24-in. depth 24.00 24 in. long - 36-in. depth 24.00 135.00 24 in. long - 48-in. depth 24.00 168.00 67 General Data Table 20. Section dimensions (inches) and weights (pounds) - unit size 6 Pipe Cabinets Length (in.) Weight (lb.) 48 in. long - 24-in. depth 48.00 142.00 48 in. long - 36-in. depth 48.00 184.00 48 in. long - 48-in. depth 48.00 226.00 226.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 284.00 96 in. long - 48-in. depth 96.00 343.00 Table 21. Filter data for unit size 6 Filter Type Area ft² Qty–Size (in.) Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 5.56 2 - 20x25 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 8.89 4 - 16x20 Side load bag or cartridge 6.67 2 - 24x20 Front load bag or cartridge 6.00 Front load HEPA 6.00 1 1 1 1 - 24x24 24x12 24x24 24x12 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 22. Coil availability - unit size 6 Section Type 1/2-in Unit Coils 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils Small 2-4 rows 1-2 rows Medium 2–8 rows 1–4 rows Extended-medium 2–8 rows 1–8 rows Medium-large 2-8 rows 1-10 rows -with access 2–6 rows 1–3 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–6 rows Large vertical 2-8 rows 1–6 rows -with access 2–8 rows 1–4 rows Table 23. Coil data for unit size 6 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1, 2, 4, 6, 8 Aluminum 6.11 1, 2, 3, 4, 6, 8, 10 Aluminum or Copper 5.33 1–24 × 32 6, 8, 10 Aluminum or Copper 5.17 1–24 × 31 1 Aluminum or Copper 5.33 1–24 × 32 1, 2, 4, 6, 8 Aluminum 2.78 1–12.50 × 32 1, 2, 3, 4, 6, 8, 10 Aluminum or Copper 2.67 1–12 × 32 1/2-inch unit coils -UA,UW, UF 1–26.25 x 33.50 5/8-inch unit coils -W, 5A, 5W, D1, TT, P2, P4, P8 -WD, D2 1-inch unit coil -NS 1/2-inch modified coil -WL 5/8-inch modified coils -W, 5A, 5W, D1, TT, P2, P4 68 CLCH-PRC022A-EN General Data Table 23. Coil data for unit size 6 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1 Aluminum or Copper 2.67 1–12 × 32 1, 2 Aluminium or Copper 2.67 1-12 x 32 2 Aluminum 2.67 1-12 x 32 1-inch modified coil -NS Multizone coils -5A, 5W, NS, TT -WL Table 24. Fan data for unit size 6 Housed Fans - Low Pressure Size/Type 12-in. FC 10-in. FC 9-in. FC 12-in. AF 10-in. BC Fan Name 12FA 10FA 9FA 12AA 10BA 9-in. BC 9BA Max rpm 1900 2100 2250 3700 4070 4375 ODP NEMA Premium motor hp range 0.75-5 0.75-5 0.75-3 0.75-7.5 0.75-3 0.75-3 Outlet area (ft²) 1.46 1.03 0.84 1.46 1.03 0.84 Bearing/Shaft size (in.) 1.00 0.75 0.75 1.00 0.75 0.75 Size/Type 12-in. FC 10-in. FC 9-in. FC 12-in. AF 10-in. BC 9-in. BC Fan name 12FB 10FB 9FB 12AB 10BB 9BB Max rpm 2115 2525 2900 4350 4650 5000 ODP NEMA Premium motor hp range 0.75-7.5 0.75-7.5 0.75-5 0.75-7.5 0.75-5 0.75-5 Outlet area (ft²) 1.46 1.03 0.84 1.46 1.03 0.84 Bearing/Shaft size (in.) 1.19 0.75 0.75 1.44 0.75 0.75 Housed Fans - High Pressure Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 15-in. AF 15-in. AF Reduced Width Nominal Width Size/Type 16-in. AF 14-in. AF 16-in. AF 14-in. AF Fan name 16PA 14PA 16PB 14PB 15NR Max rpm 3300 3670 3700 4000 3650 3650 ODP NEMA Premium motor hp range 0.75-10 0.75-7.5 0.75-10 0.75-10 1.5-10 1.5-10 Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 1.19 1.00 1.4 1.19 n/a n/a CLCH-PRC022A-EN 15NF 69 General Data Unit Size 8 Table 25. Section dimensions (inches) and weights (pounds) - unit size 8 4000 Nominal airflow 4581 Airflow at 625 fpm Height - indoor unit 37.75 (in.)3 50.50 Width (in.) Height - outdoor unit (in.)4 includes base drip lip Weight add for outdoor unit (lbs./in. of unit length) Section type 45.13 2.04 Length (in.) Weight (lb.) -Small horizontal 10.00 66.67 -Medium horizontal 14.00 82.74 -Extended-medium horizontal 19.00 102.82 Access or blank5 -Medium-large horizontal 26.50 132.94 -Large horizontal or turning 36.00 208.50 -Extra-large horizontal or turning 44.00 240.63 -Ducted inlet or ducted outlet section 10.00 66.70 Blender 26.50 173.34 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section 52.00 792.00 -Small horizontal (with 4-row UW) 10.00 205.79 -Medium horizontal (with 8-row UW) 14.00 318.97 -Extended-medium horizontal (with 8-row UW) 19.00 341.16 Coils -Medium-large horizontal (with 10-row W) 26.50 554.88 -Large horizontal or vertical (with 10-row W) 36.00 597.03 -Electric Heat Coil 44.00 480.00 -Integral-face-and-bypass (IFB) coil --Less than 4 rows 26.50 470.21 --4 rows 43.00 725.48 Controls section (includes largest available VFD) 28.50 272.00 Diffuser 14.00 80.39 -Horizontal 36.00 206.15 -Vertical 44.00 275.69 Energy Wheel 52.00 765.00 Discharge plenum Face-and-Bypass Dampers -Face-and-bypass 19.00 157.63 -External face-and-bypass 19.00 190.70 -Internal face-and-bypass or face damper only 19.00 174.82 -Belt-drive plenum (BDP) fan with motor 44.00 682.55 -Housed fan FC with motor 44.00 589.00 -Housed AF/BC fans with motor 44.00 649.40 -Direct-drive plenum fan with motor 44.00 692.86 Fan 70 CLCH-PRC022A-EN General Data Table 25. Section dimensions (inches) and weights (pounds) - unit size 8 Filters Length (in.) Weight (lb.) -Side load 2-in. angled 26.50 202.44 -Side load 4-in. angled 26.50 209.64 -Side load cartridge 12-in. or short bag 18-in. 26.50 220.46 -Side load 2-in. flat 14.00 103.59 117.09 -Side load 4-in. flat 14.00 -Side load 2-in. and 4-in. combination flat 19.00 144.56 -Long bag 30-in. 44.00 269.00 -Front-load HEPA 40.00 368.00 -Front-load cartridge 40.00 310.00 -Front-load short bag 45.00 306.00 - 200 MBH 57.00 797.90 - 300 MBH 73.00 953.50 -Building Steam 14.00 184.00 -Atmospheric 14.00 203.00 -with angled filters 36.00 208.50 -with front/back Traq and top Traq dampers 44.00 321.58 - reduced length mixing box with side/top/back/bottom airfoil damper 23.40 202.80 - 3-deck vertical discharge 61.00 1313.00 - 2-deck vertical discharge 61.00 899.00 - 3-deck horizontal discharge 52.00 1219.00 - 2-deck horizontal discharge 52.00 832.00 -3 feet 38.00 376.00 -5 feet 62.00 483.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 435.00 UV light 14.00 120.26 Gas heat Humidifier Mixing box Multizone Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 48.00 276.00 -with airfoil damper and one side Traq damper 48.00 290.00 Exhaust damper section 19.00 140.20 - Back inlet hood - airfoil and Traq 50.38 47.00 - Side inlet hood - airfoil and Traq 20.00 22.00 - Exhaust hood - airfoil 20.00 16.00 - Economizer inlet hood 48.00 61.00 Hoods Pipe Cabinets CLCH-PRC022A-EN 15 in. long - 24-in. depth 15.00 89.00 15 in. long - 36-in. depth 15.00 120.00 15 in. long - 48-in. depth 15.00 152.00 24 in. long - 24-in. depth 24.00 105.00 24 in. long - 36-in. depth 24.00 140.00 24 in. long - 48-in. depth 24.00 174.00 71 General Data Table 25. Section dimensions (inches) and weights (pounds) - unit size 8 Pipe Cabinets Length (in.) Weight (lb.) 48 in. long - 24-in. depth 48.00 148.00 48 in. long - 36-in. depth 48.00 191.00 48 in. long - 48-in. depth 48.00 234.00 233.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 293.00 96 in. long - 48-in. depth 96.00 352.00 Table 26. Filter data for unit size 8 Filter Type Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media Angled (2-in. or 4-in.) Pleated, permanent, throwaway media Side load bag or cartridge Area ft² Qty–Size (in.) 7.33 1 - 24x20 1 - 24x24 11.11 4 - 20x20 8.00 Front load bag or cartridge 6.00 Front load HEPA 7.00 4 - 24x12 1 1 1 1 - 24x24 24x12 24x30 24x12 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency Table 27. Coil availability - unit size 8 Section Type 1/2-in Unit Coils 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils Small 2-4 rows 1-2 rows Medium 2–8 rows 1–4 rows Extended-medium 2–8 rows 1–8 rows Medium-large 2-8 rows 1-10 rows -with access 2–6 rows 1–3 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–6 rows Large vertical 2-8 rows 1–6 rows -with access 2–8 rows 1–6 rows Table 28. Coil data for unit size 8 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1, 2, 4, 6, 8 Aluminum 1, 2, 3, 4, 6, 8,10 Aluminum or Copper 7.31 1–27 × 39 6, 8, 10 Aluminum or Copper 7.13 1–27 × 38 1, 2, 4, 6, 8 Aluminum or Copper 6.50 1–24 × 39 1 Aluminum or Copper 6.50 1–24 × 39 2, 4, 6, 8 Aluminum 4.95 1–18.75 × 38 1/2-inch unit coils -UA, UW, UF 7.99 1–28.75 × 40 5/8-inch unit coils -W, 5A, 5W, D1 -WD, D2 -TT, P2, P4, P8 1-inch unit coil -NS 1/2-inch modified coils -WL, LL, FD 72 CLCH-PRC022A-EN General Data Table 28. Coil data for unit size 8 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1, 2, 3, 4, 6, 8,10 Aluminum or Copper 4.88 1–18 × 39 6, 8, 10 Aluminum or Copper 4.75 1–18 × 38 1 Aluminum or Copper 4.88 1–18 × 39 1, 2 Aluminium or Copper 3.25 1-12 x 39 2 Aluminum 3.25 1-12 x 39 5/8-inch modified coils -W, 5A, 5W, D1, TT, P2, P4, P8 -WD, D2 1-inch modified coil -NS Multizone coils -5A, 5W, NS, TT -WL Table 29. Fan data for unit size 8 Housed Fans - Low Pressure Size/Type 12-in. FC 10-in. FC 9-in. FC 12n. AF 10-in. BC Fan name 12FA 10FA 9FA 12AA 10BA 9-in. BC 9BA Max rpm 1900 2100 2250 3700 4070 4375 ODP NEMA Premium motor hp range 1-5 1-5 1-3 1-7.5 1-3 1-3 Outlet area (ft²) 1.46 1.03 0.84 1.46 1.03 0.84 Bearing/Shaft size (in.) 1.00 0.75 0.75 1.00 0.75 0.75 Size/Type 12-in. FC 10-in. FC 9-in. FC 12-in. AF 10-in. BC Fan name 12FB 10FB 9FB 12AB 10BB 9BB Max rpm 2115 2525 2900 4350 4650 5000 ODP NEMA Premium motor hp range 1-7.5 1-7.5 1-5 1-10 1-5 1-5 Outlet area (ft²) 1.46 1.03 0.84 1.46 1.03 0.84 Bearing/Shaft size (in.) 1.19 0.75 0.75 1.44 0.75 0.75 Housed Fans - High Pressure Belt-drive Plenum Fans Low Pressure 9-in. BC Direct-Drive Plenum Fans High Pressure High Pressure 18-in. AF 18-in. AF Reduced Width Nominal Width Size/Type 16-in. AF 14-in. AF 16-in. AF 14-in. AF Fan name 16PA 14PA 16PB 14PB 18NR 18NF Max rpm 3300 3670 3700 4000 2979 2979 ODP NEMA Premium motor hp range 1-10 1-7.5 1-10 1-10 2-15 3-15 Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 1.19 1.00 1.34 1.19 n/a n/a CLCH-PRC022A-EN 73 General Data Unit Size 10 Table 30. Section dimensions (inches) and weights (pounds) - unit size 10 Nominal airflow 5000 Airflow at 625 fpm 6075 Height - indoor unit (in.) 37.75 Width (in.) 61.50 Height - outdoor unit (in.) includes base drip lip 45.13 Weight add for outdoor unit (lbs./in. of unit length) Section type 2.27 Length (in.) Weight (lb.) -Small horizontal 10.00 74.92 -Medium horizontal 14.00 92.66 -Extended-medium horizontal 19.00 114.83 Access or blank -Medium-large horizontal 26.50 148.08 -Large horizontal or turning 36.00 235.01 -Extra-large horizontal or turning 42.50 263.83 -Ducted inlet or ducted outlet section 10.00 74.90 Blender 36.00 238.64 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section 55.00 1011.00 -Small horizontal (with 4-row UW) 10.00 244.49 -Medium horizontal (with 8-row UW) 14.00 382.53 -Extended-medium horizontal (with 8-row UW) 19.00 406.80 Coils -Medium-large horizontal (with 10-row W) 26.50 656.63 -Large horizontal or vertical (with 10-row W) 36.00 702.74 -Electric Heat Coil 42.50 563.00 -Integral-face-and-bypass (IFB) coil --Less than 4 rows 26.50 541.93 --4 rows 43.00 835.34 Controls section (includes largest available VFD) 28.50 295.00 Diffuser 14.00 90.31 -Horizontal 36.00 232.66 -Vertical 42.50 306.29 Energy Wheel 55.00 911.00 Discharge plenum Face-and-Bypass Dampers -Face-and-bypass 19.00 178.68 -External face-and-bypass 19.00 219.68 -Internal face-and-bypass or face damper only 19.00 203.43 -Belt-drive plenum (BDP) fan with motor 42.50 875.00 -Housed fan FC with motor 42.50 721.69 -Housed AF/BC fans with motor 42.50 849.71 -Direct-drive plenum fan with motor 46.75 795.54 Fan 74 CLCH-PRC022A-EN General Data Table 30. Section dimensions (inches) and weights (pounds) - unit size 10 Filters Length (in.) Weight (lb.) -Side load 2-in. angled 26.50 225.96 -Side load 4-in. angled 26.50 247.16 -Side load cartridge 12-in. or short bag 18-in. 26.50 234.88 -Side load 2-in. flat 14.00 117.74 143.40 -Side load 4-in. flat 14.00 -Side load 2-in. and 4-in. combination flat 19.00 174.73 -Long bag 30-in. 42.50 289.00 -Front-load HEPA 40.00 408.00 -Front-load cartridge 40.00 341.00 -Front-load short bag 45.00 335.00 - 200 MBH 59.00 852.50 - 300 MBH n/a n/a - 360 MBH 77.00 1093.20 -Building Steam 14.00 226.00 -Atmospheric 14.00 252.00 -with angled filters 36.00 235.01 -with front/back Traq and top Traq dampers 42.50 356.08 - reduced length mixing box with side/top/back/bottom airfoil damper 23.40 231.60 - 3-deck vertical discharge 66.00 1671.00 - 2-deck vertical discharge 66.00 1099.00 - 3-deck horizontal discharge 52.00 1511.00 - 2-deck horizontal discharge 52.00 982.00 -3 feet 38.00 359.00 -5 feet 62.00 541.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 470.00 UV light 14.00 135.22 Gas heat Humidifier Mixing box Multizone Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 53.00 334.00 -with airfoil damper and one side Traq damper 53.00 349.00 Exhaust damper section 19.00 159.60 - Back inlet hood - airfoil and Traq 61.50 52.00 - Side inlet hood - airfoil and Traq 22.88 31.00 - Exhaust hood - airfoil 22.88 21.00 - Economizer inlet hood 53.00 68.00 Hoods Pipe Cabinets CLCH-PRC022A-EN 15 in. long - 24-in. depth 15.00 89.00 15 in. long - 36-in. depth 15.00 120.00 15 in. long - 48-in. depth 15.00 152.00 75 General Data Table 30. Section dimensions (inches) and weights (pounds) - unit size 10 Pipe Cabinets Length (in.) Weight (lb.) 24 in. long - 24-in. depth 24.00 105.00 24 in. long - 36-in. depth 24.00 140.00 24 in. long - 48-in. depth 24.00 174.00 148.00 48 in. long - 24-in. depth 48.00 48 in. long - 36-in. depth 48.00 191.00 48 in. long - 48-in. depth 48.00 234.00 233.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 293.00 96 in. long - 48-in. depth 96.00 352.00 Table 31. Filter data for unit size 10 Filter Type Area ft² Qty–Size (in.) 9.72 2 - 20x25 1 - 16x25 13.89 4 - 25x20 Side load bag or cartridge 8.67 2 - 24x20 1 - 24x12 Front load bag or cartridge 8.00 2 - 24x24 Front load HEPA 9.00 1 - 24x30 1 - 24x24 Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media Angled (2-in. or 4-in.) pleated, permanent, throwaway media Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 32. Coil availability-size 10 1/2-in Unit Coils 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils Small 2-4 rows 1 - 2 rows Medium 2–8 rows 1–4 rows Extended-medium 2–8 rows 1–8 rows Medium-large 2-8 rows 1-10 rows Section Type -with access 2–6 rows 1–3 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–6 rows Large vertical 2-8 rows 1–6 rows -with access 2–8 rows 1–6 rows Table 33. Coil data for unit size 10 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1, 2, 4, 6, 8 Aluminum 9.98 1–28.75 × 50 1, 2, 3, 4, 6, 8, 10 Aluminum or Copper 9.19 1-27 x 49 1, 2, 4, 6, 8 Aluminum or Copper 8.17 1-24 x 49 1 Aluminum or Copper 8.17 1–24 × 49 1/2-inch unit coils -UA, UW, UF 5/8-inch unit coils -W, WD, 5A, 5W, D1, D2 -TT, P2, P4, P8 1-inch unit coil -NS 76 CLCH-PRC022A-EN General Data Table 33. Coil data for unit size 10 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 2, 4, 6, 8 Aluminum 6.38 1–18.75 × 49 1, 2, 3, 4, 6, 8, 10 Aluminum or Copper 6.13 1–18 × 49 1 Aluminum or Copper 6.13 1–18 × 49 1, 2 Aluminium or Copper 6.13 1-18 x 49 2 Aluminum 6.13 1-18 x 49 1/2-inch modified coils -WL, LL, FD 5/8-inch modified coils -W, 5A, 5W, WD, D1, D2, TT, P2, P4, P8 1-inch modified coil -NS Multizone coils -5A, 5W, NS, TT -WL Table 34. Fan data for unit size 10 Housed Fans - Low Pressure Size/Type 15-in. FC 12-in. FC 10-in. FC 15-in. AF 12-in. AF 10-in. BC Fan name 15FA 12FA 10FA 15AA 12AA 10BA Max rpm 1600 1900 2100 2900 3700 4070 ODP NEMA Premium motor hp range 1-7.5 1-5 1-5 1-10 1-7.5 1-3 Outlet area (ft²) 2.05 1.46 1.03 2.05 1.46 1.03 Bearing/Shaft size (in.) 1.00 1.00 0.75 1.19 1.00 0.75 Housed Fans - High Pressure Size/Type 15-in. FC 12-in. FC 10-in. FC 15-in. AF 12-in. AF 10-in. BC Fan name 15FB 12FB 10FB 15AB 12AB 10BB Max rpm 1720 2115 2525 3500 4350 4650 ODP NEMA Premium motor hp range 1-10 1-10 1-7.5 1-15 1-10 1-5 Outlet area (ft²) 2.05 1.46 1.03 2.05 1.46 1.03 Bearing/Shaft size (in.) 1.19 1.19 0.75 1.44 1.44 1.00 Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 20-in. AF 20-in. AF Reduced Width Nominal Width Size/Type 18-in. AF 16-in. AF 18-in. AF 16-in. AF Fan name 18PA 16PA 18PB 16PB 20NR 20NF Max rpm 3000 3300 3300 3700 2771 2771 ODP NEMA Premium motor hp range 1-10 1-10 1-15 1-10 3-15 3-15 Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 1.19 1.19 1.50 1.34 n/a n/a CLCH-PRC022A-EN 77 General Data Unit Size 12 Table 35. Section dimensions (inches) and weights (pounds) - unit sizes 12 Nominal airflow 6000 Airflow at 625 fpm 8331 Height - indoor unit (in.) 41.50 Width (in.) 66.50 Height - outdoor unit (in.) includes base drip lip 49.25 Weight add for outdoor unit (lbs./in. of unit length) Section type 2.40 Length (in.) Weight (lb.) -Small horizontal 10.00 80.55 -Medium horizontal 14.00 99.61 -Extended-medium horizontal 19.00 123.43 Access or blank -Medium-large horizontal 26.50 159.18 -Large horizontal or turning 36.00 257.70 -Extra-large horizontal or turning 42.50 288.68 -Ducted inlet or ducted outlet section 10.00 80.50 Blender 36.00 264.12 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section 58.00 1165.00 -Small horizontal (with 4-row UW) 10.00 285.13 -Medium horizontal (with 8-row UW) 14.00 450.07 -Extended-medium horizontal (with 8-row UW) 19.00 476.00 Coils -Medium-large horizontal (with 10-row W) 26.50 777.26 -Large horizontal or vertical (with 10-row W) 36.00 826.53 -Electric Heat Coil 42.50 622.00 -Integral-face-and-bypass (IFB) coil --Less than 4 rows 26.50 585.86 --4 rows 43.00 901.70 Controls section (includes largest available VFD) 28.50 315.00 Diffuser 14.00 97.26 -Horizontal 36.00 255.35 -Vertical 42.50 339.58 Energy Wheel 58.00 1085.00 Discharge plenum Face-and-Bypass Dampers -Face-and-bypass 19.00 199.15 -External face-and-bypass 19.00 241.45 -Internal face-and-bypass or face damper only 19.00 227.60 -Belt-drive plenum (BDP) fan with motor 42.50 951.91 -Housed fan FC with motor 42.50 882.15 -Housed AF/BC fans with motor 42.50 920.08 -Direct-drive plenum fan with motor 48.50 912.52 Fan 78 CLCH-PRC022A-EN General Data Table 35. Section dimensions (inches) and weights (pounds) - unit sizes 12 Filters Length (in.) Weight (lb.) -Side load 2-in. angled 26.50 251.82 -Side load 4-in. angled 26.50 254.22 -Side load cartridge 12-in. or short bag 18-in. 26.50 284.12 -Side load 2-in. flat 14.00 133.81 142.66 -Side load 4-in. flat 14.00 -Side load 2-in. and 4-in. combination flat 19.00 185.69 -Long bag 30-in. 42.50 331.00 -Front-load HEPA 40.00 440.00 -Front-load cartridge 40.00 386.00 -Front-load short bag 45.00 370.00 - 200 MBH 57.00 912.60 - 300 MBH n/a n/a - 360 MBH 73.00 1131.40 - 560 MBH n/a n/a -Building Steam 14.00 269.00 -Atmospheric 14.00 276.00 -with angled filters 36.00 257.70 -with front/back Traq and top Traq dampers 42.50 396.49 - reduced length mixing box with side/top/back/bottom airfoil damper 23.40 257.60 - 3-deck vertical discharge 71.00 1899.00 - 2-deck vertical discharge 71.00 1266.00 - 3-deck horizontal discharge 57.00 1729.00 - 2-deck horizontal discharge 57.00 1145.00 -3 feet 38.00 442.00 -5 feet 62.00 678.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 498.00 UV light 14.00 146.68 Gas heat Humidifier Mixing box Multizone Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 53.00 365.00 -with airfoil damper and one side Traq damper 53.00 378.00 Exhaust damper section 19.00 176.70 66.38 69.00 Hoods - Back inlet hood - airfoil and Traq CLCH-PRC022A-EN - Side inlet hood - airfoil and Traq 22.88 42.00 - Exhaust hood - airfoil 22.88 29.00 - Economizer inlet hood 53.00 76.00 79 General Data Table 35. Section dimensions (inches) and weights (pounds) - unit sizes 12 Pipe Cabinets Length (in.) Weight (lb.) 15 in. long - 24-in. depth 15.00 94.00 15 in. long - 36-in. depth 15.00 127.00 15 in. long - 48-in. depth 15.00 161.00 111.00 24 in. long - 24-in. depth 24.00 24 in. long - 36-in. depth 24.00 147.00 24 in. long - 48-in. depth 24.00 184.00 155.00 48 in. long - 24-in. depth 48.00 48 in. long - 36-in. depth 48.00 200.00 48 in. long - 48-in. depth 48.00 245.00 244.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 305.00 96 in. long - 48-in. depth 96.00 367.00 Table 36. Filter data for unit size 12 Filter Type Area ft² Qty–Size (in.) Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 13.33 3 - 16x20 3 - 16x20 Angled (2-in. or 4-in.) pleated, permanent, throwaway media 16.67 6 - 20x20 Side load bag or cartridge 12.33 Front load bag or cartridge 10.00 Front load HEPA 10.00 3 - 20x20 2 - 12x24 1 -12x24 2 - 24x24 2 - 30x24 Table 37. Coil availability - size 12 Section Type 80 1/2-in Unit Coils 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils Small 2-4 rows 1-2 rows Medium 2–8 rows 1–4 rows Extended-medium 2–8 rows 1–8 rows Medium-large 2-8 rows 1-10 rows -with access 2–6 rows 1–3 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–6 rows Large vertical 2-8 rows 1–6 rows -with access 2–8 rows 1–6 rows CLCH-PRC022A-EN General Data Table 38. Coil data for unit size 12 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1, 2, 4, 6, 8 Aluminum 12.30 1–32.50 x 54.50 1/2-inch unit coils -UA, UW, UF, UU 5/8-inch unit coils -W, WD, D1, D2 4, 6, 8, 10 Aluminum or Copper 11.81 1–31.50 × 54 1, 2, 3, 4, 6, 8 Aluminum or Copper 11.25 1 - 30 x 54 1 Aluminum or Copper 11.25 1–30 × 54 2, 4, 6, 8 Aluminum 9.38 1-25 × 54 1, 2, 3, 4,6, 8, 10 Aluminum or Copper 9.00 1–24 × 54 1 Aluminum or Copper 9.00 1–24 × 54 1, 2 Aluminium or Copper 6.75 1-18 x 54 2 Aluminum 6.75 1-18 x 54 -W, 5A, 5W, D1, TT, P2, P4, P8 1-inch unit coil -NS 1/2-inch modified coils -WL, LL, FD 5/8-inch modified coils -W, WD, 5A, 5W, D1, D2, TT, P2, P4, P8 1-inch modified coil -NS Multizone coils -5A, 5W, NS, TT -WL Table 39. Fan data for unit size 12 Housed Fans - Low Pressure Size/Type 18-in FC 15-in FC 12-in FC 18-in AF 15-in AF 12-in AF Fan name 18FA 15FA 12FA 18AA 15AA 12AA Max rpm 1215 1600 1900 2450 2900 3700 ODP NEMA Premium motor hp range 1-7.5 1-7.5 1-5 1-10 1-10 1-7.5 Outlet area (ft²) 2.88 2.05 1.46 2.88 2.05 1.46 Bearing/Shaft size (in.) 1.00 1.00 1.00 1.19 1.19 1.00 Size/Type 18-in FC 15-in FC 12-in FC 18-in AF 15-in AF 12-in AF Fan name 18FB 15FB 12FB 18AB 15AB 12AB Max rpm 1500 1720 2115 3100 3500 4350 ODP NEMA Premium motor hp range 1-15 1-10 1-10 1-15 1-15 1-10 Outlet area (ft²) 2.88 2.05 1.46 2.88 2.05 1.46 Bearing/Shaft size (in.) 1.44 1.19 1.19 1.50 1.44 1.44 Housed Fans - High Pressure Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 22-in. AF 22-in. AF Reduced Width Nominal Width Size/Type 20-in AF 18-in AF 20-in AF 18-in AF Fan name 20PA 18PA 20PB 18PB 22NR 22NF Max rpm 2650 3000 2850 3300 2454 2454 ODP NEMA Premium motor hp range 1-15 1-10 1-15 1-15 3-15 5-20 Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 1.50 1.19 1.69 1.50 n/a n/a CLCH-PRC022A-EN 81 General Data Unit Size 14 Table 40. Section dimensions (inches) and weights (pounds) - unit size 14 Nominal airflow 7000 Airflow at 625 fpm 9025 Height - indoor unit (in.) 41.50 Width (in.) 72.00 Height - outdoor unit (in.) includes base drip lip 49.25 Weight add for outdoor unit (lbs./in. of unit length) Section type 2.51 Length (in.) Weight (lb.) Access or blank -Small horizontal 10.00 84.67 -Medium horizontal 14.00 104.57 129.44 -Extended-medium horizontal 19.00 -Medium-large horizontal 26.50 166.74 -Large horizontal or turning 36.00 271.35 -Extra-large horizontal or turning 42.50 303.68 -Ducted inlet or ducted outlet section 10.00 84.70 Blender 36.00 276.73 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section 58.00 1326.00 -Small horizontal (with 4-row UW) 10.00 307.44 -Medium horizontal (with 8-row UW) 14.00 488.32 -Extended-medium horizontal (with 8-row UW) 19.00 516.35 Coils -Medium-large horizontal (with 10-row W) 26.50 884.93 -Large horizontal or vertical (with 10-row W) 36.00 938.18 -Electric Heat Coil 42.50 666.00 -Integral-face-and-bypass (IFB) coil --Less than 4 rows 26.50 619.66 --4 rows 43.00 950.23 Controls section (includes largest available VFD) 28.50 327.00 Diffuser 14.00 102.22 -Horizontal 36.00 269.00 -Vertical 42.50 358.68 Energy Wheel 58.00 1208.00 Discharge plenum Face-and-Bypass Dampers -Face-and-bypass 19.00 209.53 -External face-and-bypass 19.00 255.80 -Internal face-and-bypass or face damper only 19.00 241.91 -Belt-drive plenum (BDP) fan with motor 42.50 1069.39 -Housed fan FC with motor 42.50 904.21 -Housed AF/BC fans with motor 42.50 942.14 -Direct-drive plenum fan with motor 48.50 936.26 Fan 82 CLCH-PRC022A-EN General Data Table 40. Section dimensions (inches) and weights (pounds) - unit size 14 Filters Length (in.) Weight (lb.) -Side load 2-in. angled 26.50 265.94 -Side load 4-in. angled 26.50 273.54 -Side load cartridge 12-in. or short bag 18-in. 26.50 303.60 -Side load 2-in. flat 14.00 141.07 154.67 -Side load 4-in. flat 14.00 -Side load 2-in. and 4-in. combination flat 19.00 201.97 -Long bag 30-in. 42.50 349.00 -Front-load HEPA 40.00 453.00 -Front-load cartridge 40.00 399.00 -Front-load short bag 45.00 384.00 - 200 MBH 57.00 937.10 - 300 MBH n/a n/a - 360 MBH 68.00 1127.90 - 560 MBH n/a n/a -Building Steam 14.00 286.00 -Atmospheric 14.00 312.00 -with angled filters 36.00 271.35 -with front/back Traq and top Traq dampers 42.50 418.78 - reduced length mixing box with side/top/back/bottom airfoil damper 28.40 298.40 - 3-deck vertical discharge 71.00 2063.00 - 2-deck vertical discharge 71.00 1380.00 - 3-deck horizontal discharge 57.00 1892.00 - 2-deck horizontal discharge 57.00 1253.00 -3 feet 38.00 461.00 -5 feet 62.00 704.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 514.00 UV light 14.00 155.07 Gas heat Humidifier Mixing box Multizone Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 57.00 407.00 -with airfoil damper and one side Traq damper 57.00 426.00 Exhaust damper section 19.00 186.80 71.88 74.00 Hoods - Back inlet hood - airfoil and Traq - Side inlet hood - airfoil and Traq 31.38 50.00 - Exhaust hood - airfoil 31.38 30.00 - Economizer inlet hood 56.50 137.00 Pipe Cabinets CLCH-PRC022A-EN 15 in. long - 24-in. depth 15.00 94.00 15 in. long - 36-in. depth 15.00 127.00 15 in. long - 48-in. depth 15.00 161.00 83 General Data Table 40. Section dimensions (inches) and weights (pounds) - unit size 14 Pipe Cabinets Length (in.) Weight (lb.) 24 in. long - 24-in. depth 24.00 111.00 24 in. long - 36-in. depth 24.00 147.00 24 in. long - 48-in. depth 24.00 184.00 155.00 48 in. long - 24-in. depth 48.00 48 in. long - 36-in. depth 48.00 200.00 48 in. long - 48-in. depth 48.00 245.00 244.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 305.00 96 in. long - 48-in. depth 96.00 367.00 Table 41. Filter data for unit size 14 Filter Type Area ft² Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 14.44 Angled (2-in. or 4-in.) pleated, permanent, throwaway media 18.06 Side load bag or cartridge 13.44 Front load bag or cartridge 10.00 Front load HEPA 10.00 Qty–Size (in.) 4 2 2 4 2 1 2 1 2 - 16x20 16x25 20x25 20x20 20x24 20x20 12x24 12x24 24x24 2 - 30x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 42. Coil availability - size 14 Section Type 84 1/2-in Unit Coils 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils Small 2-4 rows 1-2 rows Medium 2–8 rows 1–4 rows Extended-medium 2–8 rows 1–8 rows Medium-large 2-8 rows 1-10 rows -with access 2–6 rows 1–3 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–6 rows Large vertical 2-8 rows 1–6 rows -with access 2–8 rows 1–6 rows CLCH-PRC022A-EN General Data Table 43. Coil data for unit size 14 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1, 2, 4, 6, 8 Aluminum 13.65 1-32.50 x 60.50 1-31.50 x 60 1/2-inch unit coils -UA, UW, UF, UU 5/8-inch unit coils -W, D1 4, 6, 8, 10 Aluminum or Copper 13.13 1, 2, 3, 4, 6, 8 Aluminum or Copper 12.50 1-30 x 60 6, 8, 10 Aluminum or Copper 12.91 1-31.50 x 59 1 Aluminum or Copper 12.50 1–30 × 60 2, 4, 6, 8 Aluminum 10.42 1-25 x 60 1, 2, 3, 4, 6, 8, 10 Aluminum or Copper 10.00 1-24 x 60 6, 8, 10 Aluminum or Copper 9.83 1-24 x 59 6, 8 Copper 9.83 1-24 x 59 1 Aluminum or Copper 10.00 1-24 x 60 1, 2 Aluminium or Copper 7.50 1-18 x 60 2 Aluminum 7.50 1-18 x 60 W, 5A, 5W, D1, TT, P2, P4, P8 -WD, D2 1-inch unit coil -NS 1/2-inch modified coils -WL, LL, FD 5/8-inch modified coils -W, 5A, 5W, D1, TT, P2, P4, P8 -WD, D2 -WD 1-inch modified coil -NS Multizone coils -5A, 5W, NS, TT -WL Table 44. Fan data for unit size 14 Housed Fans - Low Pressure Size/Type 18-in FC 15-in FC 12-in FC 18-in AF 15-in AF 12-in AF Fan name 18FA 15FA 12FA 18AA 15AA 12AA Max rpm 1215 1600 1900 2450 2900 3700 ODP NEMA Premium motor hp range 1-7.5 1-7.5 1-5 1-10 1-7.5 1-7.5 Outlet area (ft²) 2.88 2.05 1.46 2.88 2.05 1.46 Bearing/Shaft size (in.) 1.00 1.00 1.00 1.19 1.19 1.00 Size/Type 18-in FC 15-in FC 12-in FC 18-in AF 15-in AF 12-in AF Fan name 18FB 15FB 12FB 18AB 15AB 12AB Max rpm 1500 1720 2115 3100 3500 4350 ODP NEMA Premium motor hp range 1-10 1-10 1-10 1-15 1-15 1-10 Outlet area (ft²) 2.88 2.05 1.46 2.88 2.05 1.46 Bearing/Shaft size (in.) 1.44 1.19 1.19 1.50 1.44 1.44 Housed Fans - High Pressure Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 22-in. AF 22-in. AF Nominal Width Extended Width Size/Type 22-in AF 20-in AF 22-in AF 20-in AF Fan name 22PA 20PA 22PB 20PB 22NF 22NW Max rpm 2320 2650 2650 2850 2454 2454 ODP NEMA Premium motor hp range 1-15 1-15 1-20 1-20 5-20 5-20 Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 1.50 1.50 1.69 1.69 n/a n/a CLCH-PRC022A-EN 85 General Data Unit Size 17 Table 45. Section dimensions (inches) and weights (pounds) - unit size 17 Nominal airflow Airflow at 625 fpm 8500 11,806 Height - indoor unit (in.) 49.00 Width (in.) 72.00 Height - outdoor unit (in.) includes base drip lip 56.75 Weight add for outdoor unit (lbs./in. of unit length) Section type 2.51 Length (in.) Weight (lb.) Access or blank -Small horizontal 10.00 88.41 -Medium horizontal 14.00 109.45 135.74 -Extended-medium horizontal 19.00 -Medium-large horizontal 24.50 164.66 -Large horizontal or turning 36.00 293.42 -Extra-large horizontal or turning 44.00 335.49 -Ducted inlet or ducted outlet section 10.00 88.40 Blender 36.00 303.71 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section 58.00 1390.00 -Small horizontal (with 4-row UW) 10.00 352.47 -Medium horizontal (with 8-row UW) 14.00 569.79 -Extended-medium horizontal (with 8-row UW) 19.00 599.24 Coils -Medium-large horizontal (with 10-row W) 24.50 1013.57 -Large horizontal or vertical (with 10-row W) 36.00 1081.30 -Electric Heat Coil 44.00 731.00 -Integral-face-and-bypass (IFB) coil --Less than 4 rows 26.50 733.14 --4 rows 43.00 1131.90 Controls section (includes largest available VFD) 28.50 350.00 Diffuser 14.00 107.10 -Horizontal 36.00 291.07 -Vertical 44.00 401.43 Energy Wheel 58.00 1269.00 Discharge plenum Face-and-Bypass Dampers -Face-and-bypass 19.00 224.50 -External face-and-bypass 19.00 270.77 -Internal face-and-bypass or face damper only 19.00 255.18 -Belt-drive plenum (BDP) fan with motor 44.00 1239.89 -Housed fan FC with motor 44.00 1054.64 -Housed AF/BC fans with motor 44.00 1098.21 -Direct-drive plenum fan with motor 50.00 991.99 -Side load 2-in. angled 24.50 314.12 -Side load 4-in. angled 24.50 352.07 -Side load cartridge 12-in. or short bag 18-in. 24.50 335.02 Fan Filters 86 CLCH-PRC022A-EN General Data Table 45. Section dimensions (inches) and weights (pounds) - unit size 17 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 14.00 148.02 -Side load 4-in. flat 14.00 202.82 -Side load 2-in. and 4-in. combination flat 19.00 252.57 -Long bag 30-in. 44.00 383.00 -Front-load HEPA 40.00 569.00 -Front-load cartridge 40.00 470.00 -Front-load short bag 45.00 432.00 - 200 MBH 60.00 1011.80 - 300 MBH n/a n/a - 360 MBH 71.00 1211.10 - 560 MBH 71.00 1192.00 -Building Steam 14.00 324.00 -Atmospheric 14.00 339.00 -with angled filters 36.00 293.42 -with front/back Traq and top Traq dampers 44.00 463.57 - reduced length mixing box with side/top/back/bottom airfoil damper 28.40 328.40 - 3-deck vertical discharge 71.00 2211.00 - 2-deck vertical discharge 71.00 1526.00 - 3-deck horizontal discharge 57.00 2034.00 - 2-deck horizontal discharge 57.00 1396.00 -3 feet 38.00 512.00 -5 feet 62.00 780.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 544.00 UV light 14.00 162.95 Gas heat Humidifier Mixing box Multizone Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 52.00 414.00 -with airfoil damper and one side Traq damper 52.00 431.00 Exhaust damper section 19.00 204.00 - Back inlet hood - airfoil and Traq 72.00 74.00 - Side inlet hood - airfoil and Traq 25.75 50.00 - Exhaust hood - airfoil 25.75 30.00 - Economizer inlet hood 52.00 174.00 15 in. long - 24-in. depth 15.00 105.00 15 in. long - 36-in. depth 15.00 141.00 15 in. long - 48-in. depth 15.00 178.00 24 in. long - 24-in. depth 24.00 122.00 24 in. long - 36-in. depth 24.00 162.00 24 in. long - 48-in. depth 24.00 202.00 Hoods Pipe Cabinets Pipe Cabinets CLCH-PRC022A-EN 87 General Data Table 45. Section dimensions (inches) and weights (pounds) - unit size 17 Pipe Cabinets Length (in.) Weight (lb.) 48 in. long - 24-in. depth 48.00 170.00 48 in. long - 36-in. depth 48.00 218.00 48 in. long - 48-in. depth 48.00 267.00 266.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 331.00 96 in. long - 48-in. depth 96.00 396.00 Table 46. Filter data for unit size 17 Filter Type Area ft² Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 18.89 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 28.89 Side load bag or cartridge 18.89 Front load bag or cartridge 14.00 Front load HEPA 14.00 Qty–Size (in.) 4 2 4 8 4 2 3 2 2 2 - 20x24 20x20 16x25 16x20 20x24 20x20 12x24 24x24 24x30 12x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 47. Coil availability - size 17 Section Type 1/2-in Unit Coils 5/8-in Unit Coils, 1/2-in and 5/8-in, Modified Coils Small 2-4 rows 1-2 rows Medium 2–8 rows 1–4 rows Extended-medium 2–8 rows 1–8 rows Medium-large 2-8 rows 1-10 rows -with access 2–6 rows 1–3 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–6 rows Large vertical 2-8 rows 1–6 rows -with access 2–8 rows 1–6 rows Table 48. Coil data for unit size 17 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1, 2, 4, 6, 8 Aluminum 16.81 1–40 × 60.50 1-37.50 x 60 1/2-inch unit coils -UA, UW, UF, UU 5/8-inch unit coils -D1 4, 6, 8 Aluminum or Copper 15.63 -W, D1 4, 6, 8, 10 Aluminum 15.63 1-37.50 x 60 -W, D1 4, 6, 8 Copper 15.63 1-37.50 x 60 -WD, D2 6, 8 Aluminum or Copper 15.36 1-37.50 x 59 -WD, D2 10 Aluminum 15.36 1-37.50 x 59 1-37.50 x 59 -WD, D2 -W, 5A, 5W, D1 -TT 8 Copper 15.36 1, 2, 3 Aluminum or Copper 15.00 1-36 x 60 2 Aluminum or Copper 13.75 1-33 x 60 1 Aluminum or Copper 13.75 1–33 × 60 1-inch unit coil -NS 88 CLCH-PRC022A-EN General Data Table 48. Coil data for unit size 17 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 2, 4, 6, 8 Aluminum 13.02 1-31.25 x 60 1, 2, 3, 4, 6, 8, 10 Aluminum or Copper 12.50 1-30 x 60 6, 8, 10 Aluminum or Copper 12.29 1-30 X 59 1 Aluminum or Copper 12.50 1-30 x 60 1, 2 Aluminium or Copper 7.50 1-18 x 60 2 Aluminum 7.50 1-18 x 60 1/2-inch modified coils -WL, LL, FD 5/8-inch modified coils -W, 5A, 5W, D1, TT, P2, P4, P8 -WD, D2 1-inch modified coil -NS Multizone coils -5A, 5W, NS, TT -WL Table 49. Fan data for unit size 17 Housed Fans - Low Pressure Size/Type 20-in FC 18-in FC 15-in FC 20-in AF 18-in AF 15-in AF Fan name 20FA 18FA 15FA 20AA 18AA 15AA Max rpm 1050 1215 1600 2300 2450 2900 ODP NEMA Premium motor hp range 1.5-20 1.5-7.5 1.5-7.5 1.5-15 1.5-10 1.5-10 Outlet area (ft²) 4.38 2.88 2.05 4.38 2.88 2.05 Bearing/Shaft size (in.) 1.50 1.00 1.00 1.50 1.19 1.19 Size/Type 20-in FC 18-in FC 15-in FC 20-in AF 18-in AF 15-in AF Fan name 20FB 18FB 15FB 20AB 18AB 15AB Max rpm 1330 1500 1720 2750 3100 3500 ODP NEMA Premium motor hp range 1.5-20 1.5-15 1.5-10 1.5-20 1.5-20 1.5-15 Outlet area (ft²) 4.38 2.88 2.05 4.38 2.88 2.05 Bearing/Shaft size (in.) 1.69 1.44 1.188 1.69 1.50 1.44 Housed Fans - High Pressure Belt - Drive Plenum Fans Low Pressure Direct - Drive Plenum Fans High Pressure High Pressure 24.5-in. AF 24.5-in. AF Reduced Width Nominal Width Size/Type 25-in AF 22-in AF 25-in AF 22-in AF Fan name 25PA 22PA 25PB 22PB 24NR 24NF Max rpm 2070 2320 2350 2650 2269 2269 ODP NEMA Premium motor hp range 1.5-20 1.5-15 1.5-25 1.5-20 5-20 5-20 Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 1.69 1.50 1.69 1.69 n/a n/a CLCH-PRC022A-EN 89 General Data Unit Size 21 Table 50. Section dimensions (inches) and weights (pounds) - unit sizes 21 Nominal airflow 10,500 Airflow at 625 fpm 13,456 Height - indoor unit (in.) 52.75 Width (in.) 80.00 Height - outdoor unit (in.) includes base drip lip 60.50 Weight add for outdoor unit (lbs./in. of unit length) Section type 2.68 Length (in.) Weight (lb.) Access or blank -Small horizontal 10.00 96.28 -Medium horizontal 14.00 119.10 147.62 -Extended-medium horizontal 19.00 -Medium-large horizontal 24.50 178.99 -Large horizontal or turning 34.00 314.60 -Extra-large horizontal or turning 50.25 407.29 -Ducted inlet or ducted outlet section 10.00 96.30 Blender 34.00 323.59 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section 56.00 1793.00 -Small horizontal (with 4-row UW) 10.00 433.37 -Medium horizontal (with 8-row UW) 14.00 700.27 -Extended-medium horizontal (with 8-row UW) 19.00 737.96 Coils -Medium-large horizontal (with 10-row W) 24.50 1262.10 -Large horizontal or vertical (with 10-row W) 34.00 1333.70 -Electric Heat Coil 50.30 876.00 -Integral-face-and-bypass (IFB) coil --Less than 4 rows 26.50 792.88 --4 rows 43.00 1216.48 Controls section (includes largest available VFD) 28.50 428.00 Diffuser 14.00 116.75 -Horizontal 34.00 312.25 -Vertical 50.25 486.37 Energy Wheel 56.00 1484.00 Discharge plenum Face-and-Bypass Dampers -Face-and-bypass 19.00 248.05 -External face-and-bypass 19.00 300.08 -Internal face-and-bypass or face damper only 19.00 291.55 -Belt-drive plenum (BDP) fan with motor 50.25 1443.26 -Housed fan FC with motor 50.25 1329.38 -Housed AF/BC fans with motor 50.25 1432.10 -Direct-drive plenum fan with motor 50.25 1380.92 -Side load 2-in. angled 24.50 347.50 -Side load 4-in. angled 24.50 379.13 -Side load cartridge 12-in. or short bag 18-in. 24.50 365.40 Fan Filters 90 CLCH-PRC022A-EN General Data Table 50. Section dimensions (inches) and weights (pounds) - unit sizes 21 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 14.00 165.52 -Side load 4-in. flat 14.00 213.64 -Side load 2-in. and 4-in. combination flat 19.00 268.17 -Long bag 30-in. 50.25 462.00 -Front-load HEPA 40.00 692.00 -Front-load cartridge 40.00 526.00 -Front-load short bag 45.00 474.00 - 200 MBH 60.00 1074.90 - 300 MBH n/a n/a - 360 MBH 69.00 1264.50 - 560 MBH 69.00 1246.60 - 700 MBH 75.00 1503.40 - 860 MBH 81.00 1606.40 - 1000 MBH 87.00 1364.20 - 1250-1750 MBH 87.00 1364.20 -Building Steam 14.00 354.00 -Atmospheric 14.00 396.00 -with angled filters 34.00 314.60 -with front/back Traq and top Traq dampers 50.25 555.65 - reduced length mixing box with side/top/back/bottom airfoil damper 28.40 370.10 82.00 2757.00 Gas heat Humidifier Mixing box Multizone - 3-deck vertical discharge - 2-deck vertical discharge 82.00 1882.00 - 3-deck horizontal discharge 72.00 2603.00 - 2-deck horizontal discharge 72.00 1755.00 -3 feet 38.00 573.00 -5 feet 62.00 873.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 599.00 UV light 14.00 1779.84 Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 63.00 534.00 -with airfoil damper and one side Traq damper 63.00 555.00 Exhaust damper section 19.00 229.10 - Back inlet hood - airfoil and Traq 79.88 74.00 - Side inlet hood - airfoil and Traq 29.13 50.00 - Exhaust hood - airfoil 29.13 30.00 - Economizer inlet hood 62.50 179.00 15 in. long - 24-in. depth 15.00 110.00 15 in. long - 36-in. depth 15.00 148.00 15 in. long - 48-in. depth 15.00 187.00 Hoods Pipe Cabinets CLCH-PRC022A-EN 91 General Data Table 50. Section dimensions (inches) and weights (pounds) - unit sizes 21 Pipe Cabinets Length (in.) Weight (lb.) 24 in. long - 24-in. depth 24.00 128.00 24 in. long - 36-in. depth 24.00 170.00 24 in. long - 48-in. depth 24.00 211.00 178.00 48 in. long - 24-in. depth 48.00 48 in. long - 36-in. depth 48.00 228.00 48 in. long - 48-in. depth 48.00 278.00 277.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 343.00 96 in. long - 48-in. depth 96.00 410.00 Table 51. Filter data for unit size 21 Filter Type Area ft² Qty–Size (in.) Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 21.53 3 - 25x20 1 - 25x16 3 - 16x25 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 33.33 12 - 25x16 Side load bag or cartridge 22.00 Front load bag or cartridge 18.00 Front load HEPA 21.00 3 3 3 3 3 3 - 24x24 20x24 12x24 24x24 30x24 12x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 52. Coil availability - size 21 Section Type 1/2-in Unit Coils 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils Small 2-4 rows 1-2 rows Medium 2–8 rows 1–4 rows Extended-medium 2–8 rows 1–81 rows Medium-large 2-8 rows 1-10 rows -with access 2–6 rows 1–4 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–6 rows Large vertical 2-8 rows 1–6 rows -with access 2–8 rows 1–4 rows Note: 16-row maximum for stacked coils. Table 53. Coil data for unit size 21 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1, 2, 4, 6, 8 Aluminum 20.81 1–43.75 × 68.50 1, 2, 3, 4, 6, 8 Aluminum or Copper 19.83 1-42 x 68 4, 6, 8, 10 Aluminum 19.83 1-42 x 68 4, 6, 8 Copper 19.83 1-42 x 68 -WD, D2 6, 8 Aluminum or Copper 19.54 1-42 x 67 -D2, WD 10 Aluminum 19.54 1-42 x 67 1, 2, 4, 6, 8 Aluminum or Copper 17.00 2-18 x 68 1/2-inch unit coils -UA, UW, UF, UU 5/8-inch unit coils -W, 5A, 5W, D1, D2 -W, D1 -W, WD, D1, D2 -TT, P2, P4, P8 (stacked) 92 CLCH-PRC022A-EN General Data Table 53. Coil data for unit size 21 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1 Aluminum or Copper 17.00 2–18 × 68 2, 4, 6, 8 Aluminum 15.94 1-33.75 x 68 1, 2, 3, 4, 6, 8, 101 Aluminum or Copper 15.58 1-33 x 68 -D2 6, 8, 101 Aluminum or Copper 15.35 1-33 x 67 -WD 6, 8, 10 Aluminum 15.35 1-33 x 67 -WD 6, 8 Copper 15.35 1-33 x 67 1 Aluminum or Copper 15.58 1-33 x 68 1, 2 Aluminium or Copper 11.33 1-24 x 68 2 Aluminum 11.33 1-24 x 68 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL, FD 5/8-inch modified coils -W, 5A, 5W, D1, TT 1-inch modified coil -NS Multizone coils -5A, 5W, NS, TT -WL Note: 1Copper not available for 10 row Table 54. Fan data for unit size 21 Housed Fans-Low Pressure Size/Type 22-in FC 20-in FC 18-in FC 22-in AF 20-in AF 18-in AF Fan name 22FA 20FA 18FA 22AA 20AA 18AA Max rpm 950 1050 1215 1900 2300 2450 ODP NEMA Premium motor hp range 2-20 2-20 2-7.5 2-15 2-15 2-10 Outlet area (ft²) 5.54 4.38 2.88 5.54 4.38 2.88 Bearing/Shaft size (in.) 1.5 1.5 1 1.5 1.5 1.19 Size/Type 22-in FC 20-in FC 18-in FC 22-in AF 20-in AF 18-in AF Fan name 22FB 20FB 18FB 22AB 20AB 18AB Max rpm 1200 1330 1500 2500 2750 3100 ODP NEMA Premium motor hp range 2-20 2-20 2-15 2-25 2-25 2-20 Housed Fans-High Pressure Outlet area (ft²) 5.54 4.38 2.88 5.54 4.38 2.88 Bearing/Shaft size (in.) 2.00 1.69 1.44 2.00 1.69 1.50 Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 2-20-in AF 2-20-in AF Reduced Width Nominal Width Size/Type 28-in AF 25-in AF 28-in AF 25-in AF Fan name 28PA 25PA 28PB 25PB 20NR 20NF Max rpm 1850 2070 2100 2350 2771 2771 ODP NEMA Premium motor hp range 2-25 2-20 2-30 2-30 3-15 3-15 Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 2.00 1.69 1.69 1.69 n/a n/a CLCH-PRC022A-EN 93 General Data Unit Size 22 Table 55. Section dimensions (inches) and weights (pounds) - unit size 22 Nominal airflow 11,000 Airflow at 625 fpm 13,194 Height - indoor unit (in.) Width (in.) Height - outdoor unit (in.) includes base drip lip Weight add for outdoor unit (lbs./in. of unit length) Section type 67.25 61.50 Available for indoor use only n/a n/a Length (in.) Weight (lb.) Access or blank -Small horizontal 10.00 89.63 -Medium horizontal 14.00 111.84 139.60 -Extended-medium horizontal 19.00 -Medium-large horizontal 26.50 170.14 -Large horizontal or turning 36.00 315.97 -Extra-large horizontal or turning n/a n/a -Ducted inlet or ducted outlet section 10.00 89.60 Blender 30.50 300.15 n/a n/a -Small horizontal (with 4-row UW) 10.00 433.22 -Medium horizontal (with 8-row UW) 14.00 690.67 -Extended-medium horizontal (with 8-row UW) 19.00 721.58 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section Coils -Medium-large horizontal (with 10-row W) 26.50 1175.58 -Large horizontal or vertical (with 10-row W) 36.00 1234.32 n/a n/a -Electric Heat Coil -Integral-face-and-bypass (IFB) coil --Less than 4 rows 26.50 858.31 --4 rows 43.00 1313.83 Controls section (includes largest available VFD) 28.50 419.00 Diffuser 14.00 109.49 Discharge plenum -Horizontal 36.00 313.62 -Vertical n/a n/a Energy Wheel n/a n/a Face-and-Bypass Dampers -Face-and-bypass 19.00 137.25 -External face-and-bypass 22.00 153.91 -Internal face-and-bypass or face damper only 19.00 137.25 Fan -Belt-drive plenum (BDP) fan with motor n/a n/a -Housed fan FC with motor 69.00 1399.90 -Housed AF/BC fans with motor 69.00 1548.63 -Direct-drive plenum fan with motor 69.00 1237.09 -Side load 2-in. angled 24.50 348.70 -Side load 4-in. angled 24.50 361.27 -Side load cartridge 12-in. or short bag 18-in. 24.50 342.50 Filters 94 CLCH-PRC022A-EN General Data Table 55. Section dimensions (inches) and weights (pounds) - unit size 22 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 14.00 160.19 -Side load 4-in. flat 14.00 189.17 -Side load 2-in. and 4-in. combination flat 19.00 252.01 -Long bag 30-in. 50.25 396.00 -Front-load HEPA 40.00 595.00 -Front-load cartridge 40.00 468.00 -Front-load short bag 45.00 488.00 n/a n/a -Building Steam 14.00 368.00 -Atmospheric 14.00 344.00 -with angled filters 36.00 315.97 -with front/back Traq and top Traq dampers 51.00 549.18 Gas heat Humidifier Mixing box - reduced length mixing box with side/top/back/bottom airfoil damper n/a n/a Multizone n/a n/a -3 feet 38.00 562.00 -5 feet 62.00 858.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 691.00 n/a n/a Silencer UV light Table 56. Filter data for unit size 22 Filter Type Area (ft²) Qty–Size (in.) Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 21.53 3 - 25x20 1 - 25x16 3 - 16x25 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 33.33 12 - 25x16 Side load bag or cartridge 22.00 Front load bag or cartridge 18.00 Front load HEPA 21.00 3 3 3 3 3 3 - 24x24 20x24 12x24 24x24 30x24 12x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 57. Coil availability - size 22 Section Type CLCH-PRC022A-EN 1/2-in Unit Coils 5/8-in Unit Coils 1/2-in and 5/8-in Modified Coils Small 2-4 rows 1-2 rows Medium 2–8 rows 1–4 rows Extended-medium 2–8 rows 1–8 rows Medium-large 2-8 rows 1-10 rows -with access 2–6 rows 1–4 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–6 rows Large vertical n/a n/a -with access n/a n/a 95 General Data Table 58. Coil data for unit size 22 Coil Type Rows Fin Type Area ft² 2, 4, 6, 8 Aluminum 19.97 Qty–Size (in.) 1/2-inch unit coils -UA, UW, UF, UU 1–57.50 × 50 5/8-inch unit coils -W, WD, D1, D2 4, 6, 8 Aluminum or Copper 18.89 1-55.50 x 49 6, 8, 10 Aluminum or Copper 18.89 1- 55.50 x 49 1, 2, 3 Aluminum or Copper 18.38 1-54 x 49 1 Aluminum or Copper 17.35 1 - 33 x 49 1 - 18 x 49 2, 4, 6, 8 Aluminum 12.34 1-36.25 x 49 1, 2, 3, 4, 6, 8 Aluminum or Copper 12.25 1-36 x 49 10 Aluminum 12.25 1-36 x 49 1 Aluminum or Copper 12.25 -W, WD, 5D, D1, D2 -W, 5A, 5W, D1 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL, FD 5/8-inch modified coils -W, WD, 5A, 5W, D1, D2 W, WD, D1, D2 1-inch modified coil -NS (stacked) Multizone coils n/a 2-18 x 49 n/a Table 59. Fan data for unit size 22 Housed Fans - Low Pressure Size/Type 22-in FC 20-in FC 18-in FC 22-in AF 20-in AF 18-in AF Fan name 22FA 20FA 18FA 22AA 20AA 18AA Max rpm 950 1050 1215 1900 2300 2450 ODP NEMA Premium motor hp range 2-20 2-20 2-7.5 2-15 2-15 2-10 Outlet area (ft²) 5.54 4.38 2.88 5.54 4.38 2.88 Bearing/Shaft size (in.) 1.50 1.50 1.00 1.50 1.50 1.19 Size/Type 22-in FC 20-in FC 18-in FC 22-in AF 20-in AF 18-in AF Fan name 22FB 20FB 18FB 22AB 20AB 18AB Max rpm 1200 1330 1500 2500 2750 3100 ODP NEMA Premium motor hp range 2-20 2-20 2-15 2-25 2-25 2-20 Outlet area (ft²) 5.54 4.38 2.88 5.54 4.38 2.88 Bearing/Shaft size (in.) 2.00 1.69 1.44 2.00 1.69 1.50 Housed Fans - High Pressure Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 27-in AF 27-in AF Reduced Width Nominal Width Size/Type 28-in AF 25-in AF 28-in AF 25-in AF Fan name 28PA 25PA 28PB 25PB 27NR Max rpm 1850 2070 2100 2350 2035 2035 ODP NEMA Premium motor hp range 2-25 2-20 2-30 2-30 5-25 7.5-25 96 27NF Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 2.00 1.69 1.69 1.69 n/a n/a CLCH-PRC022A-EN General Data Unit Size 25 Table 60. Section dimensions (inches) and weights (pounds) - unit size 25 Nominal airflow 12,500 Airflow at 625 fpm 16,944 Height - indoor unit (in.) 61.50 Width (in.) 80.00 Height - outdoor unit (in.) includes base drip lip 69.25 Weight add for outdoor unit (lbs./in. of unit length) Section type 2.68 Length (in.) Weight (lb.) -Small horizontal 10.00 100.65 -Medium horizontal 14.00 124.79 -Extended-medium horizontal 19.00 154.97 Access or blank -Medium-large horizontal 24.50 188.17 -Large horizontal or turning 46.00 413.45 -Extra-large horizontal or turning 56.50 476.83 -Ducted inlet or ducted outlet section 10.00 100.60 Blender 46.00 427.13 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section 56.00 1876.00 -Small horizontal (with 4-row UW) 10.00 502.46 -Medium horizontal (with 8-row UW) 14.00 817.63 -Extended-medium horizontal (with 8-row UW) 19.00 858.03 Coils -Medium-large horizontal (with 10-row W) 24.50 1478.66 -Large horizontal or vertical (with 10-row W) 46.00 1652.36 -Electric Heat Coil 46.00 1012.00 -Integral-face-and-bypass (IFB) coil --Less than 4 rows 26.50 805.52 --4 rows 43.00 1399.66 Controls section (includes largest available VFD) 28.50 453.00 Diffuser 19.00 152.62 -Horizontal 46.00 411.10 -Vertical 56.50 570.00 Energy Wheel 56.00 1595.00 Discharge plenum Face-and-Bypass Dampers -Face-and-bypass 19.00 265.62 -External face-and-bypass 19.00 317.53 -Internal face-and-bypass or face damper only 19.00 306.62 -Belt-drive plenum (BDP) fan with motor 50.25 1494.52 -Housed fan FC with motor 56.50 1487.55 -Housed AF/BC fans with motor 56.50 1572.28 -Direct-drive plenum fan with motor 56.50 1541.05 -Side load 2-in. angled 24.50 403.70 -Side load 4-in. angled 24.50 409.37 -Side load cartridge 12-in. or short bag 18-in. 24.50 439.69 Fan Filters CLCH-PRC022A-EN 97 General Data Table 60. Section dimensions (inches) and weights (pounds) - unit size 25 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 14.00 182.07 -Side load 4-in. flat 14.00 217.75 -Side load 2-in. and 4-in. combination flat 19.00 288.98 -Long bag 30-in. 46.00 489.00 -Front-load HEPA 40.00 750.00 -Front-load cartridge 40.00 580.00 -Front-load short bag 45.00 518.00 Gas heat - 200 MBH n/a n/a - 300 MBH n/a n/a 1348.00 - 360 MBH 69.00 - 560 MBH 65.00 1307.50 - 700 MBH 75.00 1599.40 - 860 MBH 81.00 1711.20 - 1000 MBH 90.00 1497.30 -Building Steam 14.00 398.00 -Atmospheric 14.00 432.00 -with angled filters 46.00 413.45 -with front/back Traq and top Traq dampers 56.50 646.61 - reduced length mixing box with side/top/back/bottom airfoil damper 28.40 408.10 - 3-deck vertical discharge 82.00 2991.00 - 2-deck vertical discharge 82.00 2108.00 - 3-deck horizontal discharge 72.00 2829.00 - 2-deck horizontal discharge 72.00 1975.00 Humidifier Mixing box Multizone Silencer -3 feet 38.00 699.00 -5 feet 62.00 1073.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 665.00 UV light 14.00 188.71 SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 57.00 548.00 -with airfoil damper and one side Traq damper 57.00 565.00 Exhaust damper section 19.00 250.50 79.88 128.00 Hoods - Back inlet hood - airfoil and Traq - Side inlet hood - airfoil and Traq 25.75 84.00 - Exhaust hood - airfoil 25.75 59.00 - Economizer inlet hood 57.00 214.00 15 in. long - 24-in. depth 15.00 122.00 15 in. long - 36-in. depth 15.00 164.00 15 in. long - 48-in. depth 15.00 207.00 Pipe Cabinets 98 CLCH-PRC022A-EN General Data Table 60. Section dimensions (inches) and weights (pounds) - unit size 25 Pipe Cabinets Length (in.) Weight (lb.) 24 in. long - 24-in. depth 24.00 142.00 24 in. long - 36-in. depth 24.00 187.00 24 in. long - 48-in. depth 24.00 233.00 195.00 48 in. long - 24-in. depth 48.00 48 in. long - 36-in. depth 48.00 249.00 48 in. long - 48-in. depth 48.00 303.00 302.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 373.00 96 in. long - 48-in. depth 96.00 443.00 Table 61. Filter data for unit size 25 Filter Type Area ft² Qty–Size (in.) Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 27.11 6 - 20x20 2 - 20x16 3 - 12x24 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 50.00 18 - 25x16 Side load bag or cartridge 26.00 6 - 20x24 3 - 12x24 Front load bag or cartridge 24.00 6 - 24x24 Front load HEPA 24.00 2 1 2 1 - 24x30 24x12 24x30 24x12 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 62. Coil availability - size 25 Section Type 1/2-in Unit Coils 5/8-in Unit Coils 1/2-in and 5/8-in Modified Coils Small 2-4 rows 1-2 rows Medium 2–8 rows 1–4 rows Extended-medium 2–8 rows 1–81 rows Medium-large 2-8 rows 1-101 rows -with access 2–6 rows 1–3 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–10 rows Large vertical 2-8 rows 1–10 rows -with access 2–8 rows 1–10 rows Note: 16-row maximum for stacked coils. Table 63. Coil data for unit size 25 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1, 2, 4, 6, 8 Aluminum 24.97 1–52.50 ×68.50 1, 2, 3, 4, 6, 8 Aluminum or Copper 24.08 1-51 x 68 4, 6, 8, 10 Aluminum 24.08 1-51 x 68 4, 6, 8 Copper 24.08 1-51 x 68 1/2-inch unit coils -UA, UW, UF, UU 5/8-inch unit coils -W, 5A, 5W, D1 -W, D1 -W, WD, 5D, D1, D2 WD, 5D, D2 -TT, P2, P4, P8 (stacked) CLCH-PRC022A-EN 6, 8, 10 Aluminum or Copper 23.73 1-51 x 67 1, 2, 4, 6, 8 Aluminum or Copper 22.67 2-24 x 68 99 General Data Table 63. Coil data for unit size 25 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1 Aluminum or Copper 22.67 2–24 × 68 2, 4, 6, 8 Aluminum 17.12 1-36.25 x 68 1, 2, 3, 4, 6, 8 Aluminum or Copper 17.00 1-36 x 68 10 Aluminum 17.00 1-36 x 68 1-36 x 68 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL, FD 5/8-inch modified coils -W, 5A, 5W, D1 -W, D1 -W, WD, D1, D2 8 Copper 17.00 6, 8 Aluminum or Copper 16.75 1-36 x 67 6, 8, 10 Aluminum 16.75 1-36 x 67 -D2 -D2, WD -WD -TT, P2, P4, P8 (stacked) 6, 8 Copper 16.75 1-36 x 67 1, 2, 4, 6, 8 Aluminum or Copper 17.00 2-18 x 68 1 Aluminum or Copper 17.00 2-18 x 68 1, 2 Aluminium or Copper 11.00 1-24 x 68 2 Aluminum 11.33 1-24 x 68 1-inch modified coil -NS (stacked) Multizone coils -5A, 5W, NS, TT -WL Table 64. Fan data for unit size 25 Housed Fans - Low Pressure Size/Type 22-in FC 20-in FC 18-in FC 22-in AF 20-in AF 18-in AF Fan name 22FA 20FA 18FA 22AA 20AA 18AA Max rpm 950 1050 1215 1900 2300 2450 ODP NEMA Premium motor hp range 3-20 3-20 3-7.5 3-15 3-15 3-10 Outlet area (ft²) 5.54 4.38 2.88 5.54 4.38 2.88 Bearing/Shaft size (in.) 1.50 1.50 1.00 1.50 1.50 1.1875 Size/Type 22-in FC 20-in FC 18-in FC 22-in AF 20-in AF 18-in AF Fan name 22FB 20FB 18FB 22AB 20AB 18AB Max rpm 1200 1330 1500 2500 2750 3100 ODP NEMA Premium motor hp range 3-25 3-25 3-15 3-30 3-30 3-20 Housed Fans - High Pressure Outlet area (ft²) 5.54 4.38 2.88 5.54 4.38 2.88 Bearing/Shaft size (in.) 2.00 1.69 1.44 2.00 1.69 1.50 Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 2- 22-in AF 2- 22-in AF Reduced Width Nominal Width Size/Type 28-in AF 25-in AF 28-in AF 25-in AF Fan name 28PA 25PA 28PB 25PB 22NR 22NF Max rpm 1850 2070 2100 2350 2454 2454 ODP NEMA Premium motor hp range 3-25 3-20 3-30 3-30 3-15 5-20 Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 2.00 1.69 1.69 1.69 n/a n/a 100 CLCH-PRC022A-EN General Data Unit Size 26 Table 65. Section dimensions (inches) and weights (pounds) - unit size 26 Nominal airflow 13,000 Airflow at 625 fpm 18,231 Height - indoor unit (in.) Width (in.) Height - outdoor unit (in.) includes base drip lip Weight add for outdoor unit (lbs./in. of unit length) Section type 85.50 61.50 Available for indoor use only n/a n/a Length (in.) Weight (lb.) Access or blank -Small horizontal 10.00 98.73 -Medium horizontal 14.00 123.71 154.93 -Extended-medium horizontal 19.00 -Medium-large horizontal 26.50 189.27 -Large horizontal or turning 46.00 428.50 -Extra-large horizontal or turning n/a n/a -Ducted inlet or ducted outlet section 10.00 98.70 Blender 36.00 385.06 n/a n/a -Small horizontal (with 4-row UW) 10.00 523.01 -Medium horizontal (with 8-row UW) 14.00 840.58 -Extended-medium horizontal (with 8-row UW) 19.00 878.74 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section Coils -Medium-large horizontal (with 10-row W) 26.50 1503.93 -Large horizontal or vertical (with 10-row W) 46.00 1652.73 n/a n/a -Integral-face-and-bypass (IFB) coil --Less than 4 rows 26.50 1047.84 --4 rows 43.00 1613.03 Controls section (includes largest available VFD) 28.50 464.00 Diffuser 19.00 152.58 -Electric Heat Coil Discharge plenum -Horizontal 46.00 426.15 -Vertical n/a n/a Energy Wheel n/a n/a Face-and-Bypass Dampers -Face-and-bypass 19.00 152.58 -External face-and-bypass 27.75 207.22 -Internal face-and-bypass or face damper only 19.00 152.58 Fan -Belt-drive plenum (BDP) fan with motor n/ n/a -Housed fan FC with motor 69.00 1589.43 -Housed AF/BC fans with motor 69.00 1687.15 -Direct-drive plenum fan with motor 69.00 1600.04 -Side load 2-in. angled 24.50 418.53 -Side load 4-in. angled 24.50 470.37 -Side load cartridge 12-in. or short bag 18-in. 24.50 440.65 Filters CLCH-PRC022A-EN 101 General Data Table 65. Section dimensions (inches) and weights (pounds) - unit size 26 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 14.00 177.12 -Side load 4-in. flat 14.00 254.10 -Side load 2-in. and 4-in. combination flat 19.00 326.16 -Long bag 30-in. 37.25 462.00 -Front-load HEPA 40.00 837.00 -Front-load cartridge 40.00 553.00 -Front-load short bag 45.00 574.00 n/a n/a -Building Steam 14.00 500.00 -Atmospheric 14.00 396.00 46.00 428.50 n/a n/a Gas heat Humidifier Mixing box -with angled filters -with front/back Traq and top Traq dampers - reduced length mixing box with side/top/back/bottom airfoil damper n/a n/a Multizone n/a n/a Silencer -3 feet 38.00 659.00 -5 feet 62.00 1005.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 778.00 n/a n/a UV light Table 66. Filter data for unit size 26 Filter Type Area (ft²) Qty–Size (in.) Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 27.11 6 - 20x20 2 - 20x16 3 - 12x24 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 50.00 18 - 25x16 Side load bag or cartridge 26.00 6 - 20x24 3 - 12x24 Front load bag or cartridge 24.00 6 - 24x24 24.00 2 1 2 1 Front load HEPA - 24x30 24x12 24x30 24x12 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 67. Coil availability - size 26 Section Type Small 1/2-in Unit Coils 5/8-in Unit Coils 1/2-in and 5/8-in Modified Coils 2-4 rows unstacked, 2 row stacked 1-2 rows 2–8 rows unstacked, 2-6 rows stacked w/out IDP, 2-4 rows with IDP 1–4 rows Extended-medium 2–8 rows 1–8 rows w/out IDP, 1-6 rows w/ IDP Medium-large 2-8 rows 1-10 rows 2-6 rows unstacked, 2-4 stacked without IDP, 2 row stacked with IDP 1–4 rows unstacked, 1-3 rows stacked w/out IDP, 1-2 rows stacked w/ IDP Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–10 rows n/a n/a Medium -with access Large vertical Note: IDP = intermediate drain pan 102 CLCH-PRC022A-EN General Data Table 68. Coil data for unit size 26 Coil Type Rows Fin Type Area (ft²) Qty–Size (in.) 2, 4, 6, 8 Aluminum 24.67 2–36.25 × 49 1, 2, 3, 4, 6, 8 Aluminum or Copper 24.50 2-36 x 49 4, 6, 8, 10 Aluminum 24.50 2-36 x 49 1 Aluminum or Copper 22.46 1 - 30 x 49 2 - 18 x 49 2, 4, 6, 8 Aluminum 18.72 1-55 x 49 4, 6 Aluminum 19.14 1-31.25 x 49 1-25 x 49 1, 2, 3, 4, 6, 8 Aluminum or Copper 18.38 1-54 x 49 4, 6, 8, 10 Aluminum 18.38 1-54 x 49 1 Aluminum or Copper 18.38 1-30 x 49 1-24 x 49 1/2-inch unit coils -UA, UW, UF, UU (stacked) 5/8-inch unit coils -W, WD, 5A, 5W, D1, D2 (stacked) W, WD, D1, D2 (stacked) 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL -FD (stacked) 5/8-inch modified coils -W, WD, 5A, 5W, D1, D2 -WD, D1, D2 1-inch modified coil -NS (stacked) Multizone coils n/a n/a Table 69. Fan data for unit size 26 Housed Fans - Low Pressure Size/Type 22-in FC 20-in FC 18-in FC 22-in AF 20-in AF 18-in AF Fan name 22FA 20FA 18FA 22AA 20AA 18AA Max rpm 950 1050 1215 1900 2300 2450 ODP NEMA Premium motor hp range 3-20 3-20 3-7.5 3-15 3-15 3-10 Outlet area (ft²) 5.54 4.38 2.88 5.54 4.38 2.88 Bearing/Shaft size (in.) 1.50 1.50 1.00 1.50 1.50 1.19 Size/Type 22-in FC 20-in FC 18-in FC 22-in AF 20-in AF 18-in AF Fan name 22FB 20FB 18FB 22AB 20AB 18AB Max rpm 1200 1330 1500 2500 2750 3100 ODP NEMA Premium motor hp range 3-25 3-25 3-15 3-30 3-30 3-20 Outlet area (ft²) 5.54 4.38 2.88 5.54 4.38 2.88 Bearing/Shaft size (in.) 2.00 1.69 1.44 2.00 1.69 1.50 Housed Fans - High Pressure Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 30-in AF 30-in AF Reduced Width Nominal Width Size/Type 28-in AF 25-in AF 28-in AF 25-in AF Fan name 28PA 25PA 28PB 25PB 30NR Max rpm 1850 2070 2100 2350 1851 1851 ODP NEMA Premium motor hp range 3-25 3-20 3-30 3-30 7.5-25 10-40 Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 2.00 1.69 1.69 1.69 n/a n/a CLCH-PRC022A-EN 30NF 103 General Data Unit Size 30 Table 70. Section dimensions (inches) and weights (pounds) - unit size 30 Nominal airflow 15,000 Airflow at 625 fpm 19,025 Height - indoor unit (in.) 61.50 Width (in.) 93.50 Height - outdoor unit (in.) includes base drip lip 69.25 Weight add for outdoor unit (lbs./in. of unit length) Section type 2.94 Length (in.) Weight (lb.) -Small horizontal 10.00 110.78 -Medium horizontal 14.00 136.97 -Extended-medium horizontal 19.00 169.71 Access or blank -Medium-large horizontal 24.50 205.72 -Large horizontal or turning 46.00 457.18 -Extra-large horizontal or turning 56.50 525.93 -Ducted inlet or ducted outlet section 10.00 110.80 Blender 46.00 470.25 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section 58.00 2029.00 -Small horizontal (with 4-row UW) 10.00 572.50 -Medium horizontal (with 8-row UW) 14.00 941.48 -Extended-medium horizontal (with 8-row UW) 19.00 985.30 Coils -Medium-large horizontal (with 10-row W) 24.50 1701.77 -Large horizontal or vertical (with 10-row W) 46.00 1890.19 -Electric Heat Coil 56.50 1244.00 -Integral-face-and-bypass (IFB) coil --Less than 4 rows 26.50 940.46 --4 rows 43.00 1439.40 Controls section (includes largest available VFD) 28.50 487.00 Diffuser 19.00 167.36 -Horizontal 46.00 454.83 -Vertical 56.50 634.27 Energy Wheel 58.00 1868.00 Discharge plenum Face-and-Bypass Dampers -Face-and-bypass 19.00 291.36 -External face-and-bypass 19.00 353.22 -Internal face-and-bypass or face damper only 19.00 341.36 -Belt-drive plenum (BDP) fan with motor 52.50 1751.34 -Housed fan FC with motor 56.50 1710.85 -Housed AF/BC fans with motor 56.50 1797.21 -Direct-drive plenum fan with motor 56.50 1652.91 Fan 104 CLCH-PRC022A-EN General Data Table 70. Section dimensions (inches) and weights (pounds) - unit size 30 Filters Length (in.) Weight (lb.) -Side load 2-in. angled 24.50 454.19 -Side load 4-in. angled 24.50 465.65 -Side load cartridge 12-in. or short bag 18-in. 24.50 479.36 -Side load 2-in. flat 14.00 198.93 249.73 -Side load 4-in. flat 14.00 -Side load 2-in. and 4-in. combination flat 19.00 326.58 -Long bag 30-in. 46.00 523.00 -Front-load HEPA 40.00 822.00 -Front-load cartridge 40.00 651.00 -Front-load short bag 45.00 567.00 Gas heat - 200 MBH n/a n/a - 300 MBH n/a n/a - 360 MBH 66.00 1298.90 - 560 MBH 66.00 1441.80 - 700 MBH 76.00 1745.60 - 860 MBH 76.00 1804.80 - 1000 MBH 85.00 1560.00 -Building Steam 14.00 452.00 -Atmospheric 19.00 528.00 -with angled filters 46.00 457.18 -with front/back Traq and top Traq dampers 56.50 715.15 - reduced length mixing box with side/top/back/bottom airfoil damper 32.50 485.80 - 3-deck vertical discharge 82.00 3425.00 - 2-deck vertical discharge 82.00 2413.00 - 3-deck horizontal discharge 72.00 3267.00 - 2-deck horizontal discharge 72.00 2264.00 Humidifier Mixing box Multizone Silencer -3 feet 38.00 800.00 -5 feet 62.00 1215.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 711.00 UV light 14.00 218.33 SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 63.00 649.00 -with airfoil damper and one side Traq damper 63.00 689.00 Exhaust damper section 19.00 280.40 Hoods CLCH-PRC022A-EN Length (in.) Weight (lb.) - Back inlet hood - airfoil and Traq 93.38 166.00 - Side inlet hood - airfoil and Traq 27.88 96.00 - Exhaust hood - airfoil 27.88 67.00 - Economizer inlet hood 62.50 224.00 105 General Data Table 70. Section dimensions (inches) and weights (pounds) - unit size 30 Pipe Cabinets 15 in. long - 24-in. depth 15.00 15 in. long - 36-in. depth 15.00 122.00 164.00 15 in. long - 48-in. depth 15.00 207.00 142.00 24 in. long - 24-in. depth 24.00 24 in. long - 36-in. depth 24.00 187.00 24 in. long - 48-in. depth 24.00 233.00 195.00 48 in. long - 24-in. depth 48.00 48 in. long - 36-in. depth 48.00 249.00 48 in. long - 48-in. depth 48.00 303.00 302.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 373.00 96 in. long - 48-in. depth 96.00 443.00 Table 71. Filter data for unit size 30 Filter Type Area (ft²) Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 30.44 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 56.67 Side load bag or cartridge 28.22 Front load bag or cartridge 28.00 Front load HEPA 28.00 Qty–Size (in.) 6 - 20x24 2 - 20x16 3 - 12x24 6 - 16x25 18 - 16x20 8 - 20x20 3 - 12x24 6 - 24x24 2 - 12x24 2 - 24x30 1 - 24x24 2 - 24x30 1 - 24x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 72. Coil availability - size 30 Section Type 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils Small 2-4 rows 1-2 rows Medium 2–8 rows 1–4 rows Extended-medium 2–8 rows 1–81 rows Medium-large 2-8 rows 1-101 rows -with access 2–6 rows 1–3 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–101 rows Large vertical 2-8 rows 1–10 rows -with access 2–8 rows 1–10 rows Note: 106 1/2-in Unit Coils 16-row maximum for stacked coils. CLCH-PRC022A-EN General Data Table 73. Coil data for unit size 30 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1, 2, 4, 6, 8 Aluminum 29.90 1–52.50 × 82 1, 2, 3, 4, 6, 8 Aluminum or Copper 28.69 1-51 x 81 4, 6, 8, 10 Aluminum 28.69 1-51 x 81 1/2-inch unit coils -UA, UW, UF, UU 5/8-inch unit coils -W, WD, 5D, 5A, 5W, D1, D2 -W, WD, 5D, D1, D2 -W, WD, 5D, D1, D2 -TT, P2, P4, P8 (stacked) 4, 6, 8 Copper 28.69 1-51 x 81 1, 2, 4, 6, 8 Aluminum or Copper 27.00 2-24 x 81 1 Aluminum or Copper 27.00 2–24 x 81 2, 4, 6, 8 Aluminum 20.39 1-36.25 x 81 1-36 x 81 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL, FD 5/8-inch modified coils -W, 5A, 5W, D1, D2 1, 2, 3, 4, 6, 8 Aluminum or Copper 20.25 -W, WD, D1, D2 6, 8, 10 Aluminum 20.25 1-36 x 81 -W, WD, D1, D2 8 Copper 20.25 1-36 x 81 1, 2, 4, 6, 8 Aluminum or Copper 20.25 2-18 x 81 1 Aluminum or Copper 20.25 2-18 x 81 1, 2 Aluminium or Copper 13.50 1-24 x 81 2 Aluminum 13.50 1-24 x 81 -TT, P2, P4, P8 (stacked) 1-inch modified coil -NS (stacked) Multizone coils -5A, 5W, NS, TT -WL Table 74. Fan data for unit size 30 Housed Fans - Low Pressure Size/Type 25-in FC 22-in FC 20-in FC 25-in AF 22-in AF 20-in AF Fan name 25FA 22FA 20FA 25AA 22AA 20AA Max rpm 850 950 1050 1650 1900 2300 ODP NEMA Premium motor hp range 3-20 3-20 3-20 3-20 3-15 3-15 Outlet area (ft²) 6.94 5.54 4.38 6.94 5.54 4.38 Bearing/Shaft size (in.) 1.69 1.50 1.50 1.69 1.50 1.50 Size/Type 25-in FC 22-in FC 20-in FC 25-in AF 22-in AF 20-in AF Fan name 25FB 22FB 20FB 25AB 22AB 20AB Max rpm 1025 1200 1330 2200 2500 2750 ODP NEMA Premium motor hp range 3-30 3-30 3-25 3-40 3-30 3-30 Outlet area (ft²) 6.94 5.54 4.38 6.94 5.54 4.38 Bearing/Shaft size (in.) 2.44 2.00 1.69 2.00 2.00 1.69 Housed Fans - High Pressure Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 2-24.5-in AF 2-24.5-in AF Reduced Width Nominal Width Size/Type 32-in AF 28-in AF 32-in AF 28-in AF Fan name 32PA 28PA 32PB 28PB 24NR 24NF Max rpm 1600 1850 1800 2100 2269 2269 ODP NEMA Premium motor hp range 3-25 3-25 3-40 3-40 5-20 5-20 Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 2.00 2.00 1.69 1.69 n/a n/a CLCH-PRC022A-EN 107 General Data Unit Size 31 Table 75. Section dimensions (inches) and weights (pounds) - unit size 31 Nominal airflow 15,500 Airflow at 625 fpm 22,138 Height - indoor unit (in.) Width (in.) Height - outdoor unit (in.) includes base drip lip 85.50 72.00 Available for indoor use only n/a n/a Length (in.) Weight (lb.) -Small horizontal 10.00 106.61 -Medium horizontal 14.00 133.18 -Extended-medium horizontal 19.00 166.39 Weight add for outdoor unit (lbs./in. of unit length) Section type Access or blank -Medium-large horizontal 26.50 202.93 -Large horizontal or turning 46.00 467.28 -Extra-large horizontal or turning n/a n/a -Ducted inlet or ducted outlet section 10.00 106.60 Blender 40.00 449.80 n/a n/a -Small horizontal (with 4-row UW) 10.00 594.43 -Medium horizontal (with 8-row UW) 14.00 968.56 -Extended-medium horizontal (with 8-row UW) 19.00 1009.31 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section Coils -Medium-large horizontal (with 10-row W) 26.50 1737.73 -Large horizontal or vertical (with 10-row W) 46.00 1896.66 n/a n/a -Integral-face-and-bypass (IFB) coil --Less than 4 rows 26.50 1190.19 --4 rows 43.00 1836.97 Controls section (includes largest available VFD) 28.50 496.00 Diffuser 19.00 164.04 -Electric Heat Coil Discharge plenum -Horizontal 46.00 464.93 -Vertical n/a n/a Energy Wheel n/a n/a Face-and-Bypass Dampers -Face-and-bypass 19.00 164.04 -External face-and-bypass 27.75 222.16 -Internal face-and-bypass or face damper only 19.00 164.04 Fan -Belt-drive plenum (BDP) fan with motor n/a n/a -Housed fan FC with motor 73.25 1832.18 -Housed AF/BC fans with motor 73.25 1979.55 -Direct-drive plenum fan with motor 73.25 1673.71 -Side load 2-in. angled 24.50 469.97 -Side load 4-in. angled 24.50 477.66 -Side load cartridge 12-in. or short bag 18-in. 24.50 487.55 Filters 108 CLCH-PRC022A-EN General Data Table 75. Section dimensions (inches) and weights (pounds) - unit size 31 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 14.00 198.17 -Side load 4-in. flat 14.00 241.97 -Side load 2-in. and 4-in. combination flat 19.00 322.00 -Long bag 30-in. 37.25 506.00 -Front-load HEPA 40.00 874.00 -Front-load cartridge 40.00 637.00 -Front-load short bag 45.00 623.00 n/a n/a -Building Steam 14.00 561.00 -Atmospheric 19.00 471.00 46.00 467.28 n/a n/a Gas heat Humidifier Mixing box -with angled filters -with front/back Traq and top Traq dampers - reduced length mixing box with side/top/back/bottom airfoil damper n/a n/a Multizone n/a n/a Silencer -3 feet 38.00 826.00 -5 feet 62.00 1272.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 826.00 n/a n/a UV light Table 76. Filter data for unit size 31 Filter Type Area (ft²) Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 30.44 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 56.67 Side load bag or cartridge 28.22 Front load bag or cartridge 28.00 Front load HEPA 28.00 Qty–Size (in.) 6 - 20x24 2 - 20x16 3 - 12x24 6 - 16x25 18 - 16x20 8 - 20x20 3 - 12x24 6 - 24x24 2 - 12x24 2 - 24x30 1 - 24x24 2 - 24x30 1 - 24x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 77. Coil availability - size 31 Section Type Small 1/2-in Unit Coils 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils 2-4 rows unstacked, 2 rows stacked 1-2 rows 2–8 rows unstacked, 2-6 rows stacked without IDP, 2-4 rows stacked with IDP 1–4 rows Extended-medium 2–8 rows 1–8 without IDP 1-6 rows with IDP Medium-large 2-8 rows 1-10 rows 2–6 rows unstacked, 2-4 rows stacked without IDP 1–4 rows unstacked, 1-3 rows stacked without IDP, 1-2 rows stacked with IDP Medium -with access Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–10 rows n/a n/a Large vertical CLCH-PRC022A-EN 109 General Data Table 78. Coil data for unit size 31 Coil Type Rows Fin Type Area (ft²) Qty–Size (in.) 2, 4, 6, 8 Aluminum 29.96 1–36.25 x 59.50 1, 2, 3, 5, 6, 8 Aluminum or Copper 29.50 1-36 x 59 10 Aluminum 29.50 2-36 x 59 1 Aluminum or Copper 27.04 1-30 x 59 2-18 x 59 2, 4, 6, 8 Aluminum 22.53 1-55 x 59 1/2-inch unit coils -UA, UW, UF, UU (stacked) 5/8-inch unit coils -W, WD, 5A, 5W, D1, D2 (stacked) -W, WD, D1, D2 (stacked) 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL 4, 6 Aluminum 23.05 1-31.25 x 59 1-25 x 59 1, 2, 3, 4, 6, 8 Aluminum or Copper 22.13 1-54 x 59 4, 6, 8, 10 Aluminum 22.13 1-54 x 59 1 Aluminum or Copper 22.13 1-30 x 59 1-24 x 59 -FD (stacked) 5/8-inch modified coils -W, WD, 5A, 5W, D1, D2 W, WD, D1, D2 1-inch modified coil -NS (stacked) Multizone coils n/a n/a Table 79. Fan data for unit size 31 Housed Fans - Low Pressure Size/Type 25-in FC 22-in FC 20-in FC 25-in AF 22-in AF 20-in AF Fan name 25FA 22FA 20FA 25AA 22AA 20AA Max rpm 850 950 1050 1650 1900 2300 ODP NEMA Premium motor hp range 3-20 3-20 3-20 3-20 3-15 3-15 Outlet area (ft²) 6.94 5.54 4.38 6.94 5.54 4.38 Bearing/Shaft size (in.) 1.69 1.50 1.50 1.69 1.50 1.50 Size/Type 25-in FC 22-in FC 20-in FC 25-in AF 22-in AF 20-in AF Fan name 25FB 22FB 20FB 25AB 22AB 20AB Max rpm 1025 1200 1330 2200 2500 2750 ODP NEMA Premium motor hp range 3-30 3-30 3-25 3-40 3-30 3-30 Outlet area (ft²) 6.94 5.54 4.38 6.94 5.54 4.38 Bearing/Shaft size (in.) 2.44 2.00 1.69 2.00 2.00 1.69 Housed Fans - High Pressure Belt-drive Plenum Fans Low Pressure Size/Type n/a n/a Direct-Drive Plenum Fans High Pressure n/a n/a High Pressure 2-24.5-in AF 2-24.5-in AF Reduced Width Nominal Width Fan name 24NR 24NF Max rpm 2269 2269 ODP NEMA Premium motor hp range 5-20 5-20 Outlet area (ft²) n/a n/a Bearing/Shaft size (in.) n/a n/a 110 CLCH-PRC022A-EN General Data Unit Size 35 Table 80. Section dimensions (inches) and weights (pounds) - unit size 35 Nominal airflow 17,500 Airflow at 625 fpm 23,263 Height - indoor unit (in.) Width (in.) Height - outdoor unit (in.) includes base drip lip Weight add for outdoor unit (lbs./in. of unit length) Section type 67.25 100.00 75.00 3.02 Length (in.) Weight (lb.) -Small horizontal 10.00 211.11 -Medium horizontal 14.00 241.53 -Extended-medium horizontal 19.00 279.57 Access or blank -Medium-large horizontal 24.50 321.40 -Large horizontal or turning 48.00 514.42 -Extra-large horizontal or turning 63.75 624.86 -Ducted inlet or ducted outlet section 10.00 211.10 Blender 48.00 540.76 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section 56.00 2914.00 Coils -Small horizontal (with 4-row UW) 10.00 690.59 -Medium horizontal (with 8-row UW) 14.00 1094.27 1148.70 -Extended-medium horizontal (with 8-row UW) 19.00 -Medium-large horizontal (with 10-row W) 24.50 1955.08 -Large horizontal or vertical (with 10-row W) 48.00 2131.70 -Electric Heat Coil 63.80 1666.00 -Integral-face-and-bypass (IFB) coil -Less than 4 rows 29.50 1129.66 --4 rows 43.00 1677.52 Controls section (includes largest available VFD) 28.50 637.00 Diffuser 24.50 319.05 -Horizontal 48.00 627.24 -Vertical 63.75 876.48 Energy Wheel 61.00 2403.00 Discharge plenum Face-and-Bypass Dampers -Face-and-bypass 19.00 473.39 -External face-and-bypass 22.00 566.46 -Internal face-and-bypass or face damper only 19.00 502.53 -Belt-drive plenum (BDP) fan with motor 53.50 2368.54 -Housed fan FC with motor 63.75 2400.18 -Housed AF/BC fans with motor 63.75 2429.71 -Direct-drive plenum fan with motor 63.75 2057.87 -Side load 2-in. angled 24.50 593.86 -Side load 4-in. angled 24.50 594.02 -Side load cartridge 12-in. or short bag 18-in. 24.50 681.24 Fan Filters CLCH-PRC022A-EN 111 General Data Table 80. Section dimensions (inches) and weights (pounds) - unit size 35 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 14.00 319.66 -Side load 4-in. flat 14.00 359.20 -Side load 2-in. and 4-in. combination flat 19.00 476.00 -Long bag 30-in. 37.25 657.00 -Front-load HEPA 40.00 986.00 -Front-load cartridge 40.00 868.00 -Front-load short bag 45.00 751.00 Gas heat - 200 MBH n/a n/a - 300 MBH n/a n/a 1402.10 - 360 MBH 66.00 - 560 MBH 66.00 1594.60 - 700 MBH 73.00 1895.20 - 860 MBH 80.00 2046.30 80.00 1723.70 101.00 2540.80 - 1000 MBH - 1250-1750 MBH - 2000 MBH n/a n/a - 2400 MBH n/a n/a -Building Steam 14.00 544.00 -Atmospheric 19.00 581.00 -with angled filters 48.00 519.12 -with front/back Traq and top Traq dampers 63.75 966.49 - reduced length mixing box with side/top/back/bottom airfoil damper 35.50 708.50 - 3-deck vertical discharge 92.00 4263.00 - 2-deck vertical discharge 92.00 2965.00 - 3-deck horizontal discharge 78.00 4020.00 - 2-deck horizontal discharge 78.00 2725.00 Humidifier Mixing box Multizone Silencer -3 feet 38.00 918.00 -5 feet 62.00 1335.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 882.00 UV light 14.00 325.48 SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 75.00 931.00 -with airfoil damper and one side Traq damper 75.00 973.00 Exhaust damper section 24.50 450.80 - Back inlet hood - airfoil and Traq 99.88 176.00 - Side inlet hood - airfoil and Traq 40.88 122.00 - Exhaust hood - airfoil 40.88 73.00 - Economizer inlet hood 75.00 195.00 Hoods 112 CLCH-PRC022A-EN General Data Table 80. Section dimensions (inches) and weights (pounds) - unit size 35 Pipe Cabinets Length (in.) Weight (lb.) 15 in. long - 24-in. depth 15.00 130.00 15 in. long - 36-in. depth 15.00 175.00 15 in. long - 48-in. depth 15.00 220.00 151.00 24 in. long - 24-in. depth 24.00 24 in. long - 36-in. depth 24.00 199.00 24 in. long - 48-in. depth 24.00 247.00 207.00 48 in. long - 24-in. depth 48.00 48 in. long - 36-in. depth 48.00 263.00 48 in. long - 48-in. depth 48.00 320.00 319.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 392.00 96 in. long - 48-in. depth 96.00 466.00 Table 81. Filter data for unit size 35 Filter Type Area (ft²) Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 37.22 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 63.33 Side load bag or cartridge 34.67 Front load bag or cartridge 34.00 Front load HEPA 30.00 Qty–Size (in.) 8 - 20x24 3 - 16x25 1 - 16x20 18 - 16x25 6 - 16x20 8 - 20x24 4 - 12x24 5 - 12x24 6 - 24x24 3 - 24x30 3 - 30x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 82. Coil availability - size 35 Section Type 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils Small 2-4 rows 1-2 rows Medium 2–8 rows 1–4 rows Extended-medium 2–8 rows 1–8 rows1 Medium-large 2-8 rows 1-10 rows -with access 2–4 rows 1–3 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–10 rows Large vertical 2-8 rows 1–6 rows -with access 2–8 rows 1–6 rows Note: CLCH-PRC022A-EN 1/2-in Unit Coils 16-row maximum for stacked coils. 113 General Data Table 83. Coil data for unit size 35 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 2, 4, 6, 8 Aluminum 34.94 1–57.50 × 87.50 4, 6, 8, 10 Aluminum or Copper 33.53 1-55.50 x 87 1, 2, 3 Aluminum or Copper 32.63 1-54 x 87 1 Aluminum or Copper 30.81 1-33 x 87 1-18 x 87 2, 4, 6, 8 Aluminum 21.90 1-36.25 x 87 1, 2, 3, 4, 6, 8, 10 Aluminum or Copper 21.75 1-36 x 87 1 Aluminum or Copper 21.75 2-18 x 87 1, 2 Aluminium or Copper 18.13 1-30 x 87 2 Aluminum 18.13 1-30 x 87 1/2-inch unit coils -UA, UW, UF, UU 5/8-inch unit coils -W, WD, 5D, D1, D2 - W, 5A, 5W, D1 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL, FD 5/8-inch modified coils -W, WD, 5A, 5W, D1, D2 1-inch modified coil -NS (stacked) Multizone coils -5A, 5W, NS -WL Table 84. Fan data for unit size 35 Housed Fans - Low Pressure Size/Type 25-in. FC 22-in. FC 20-in. FC 25-in. AF 22-in. AF 20-in. AF Fan name 25FA 22FA 20FA 25AA 22AA 20AA Max rpm 850 950 1050 1650 1900 2300 ODP NEMA Premium motor hp range 7.5-20 7.5-20 7.5-20 7.5-20 7.5-15 7.5-15 Outlet area (ft²) 6.95 5.54 4.38 6.95 5.54 4.38 Bearing/Shaft size (in.) 1.69 1.50 1.50 1.69 1.50 1.50 Housed Fans - High Pressure Size/Type 25-in. FC 22-in. FC 20-in. FC 25-in. AF 22-in. AF 20-in. AF Fan name 25FB 22FB 20FB 25AB 22AB 20AB Max rpm 1025 1200 1330 2200 2500 2750 ODP NEMA Premium motor hp range 7.5-40 7.5-30 7.5-25 7.5-40 7.5-40 7.5-30 Outlet area (ft²) 6.95 5.54 4.38 6.95 5.54 4.38 Bearing/Shaft size (in.) 2.44 2.00 1.69 2.00 2.00 1.69 Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 2- 24.5-in AF 2-24.5-in AF Nominal Width Extended Width Size/Type 36-in. AF 32-in. AF 36-in. AF 32-in. AF Fan name 36PA 32PA 36PB 32PB 24NF 24NW Max rpm 1350 1600 1600 1800 2269 2269 ODP NEMA Premium motor hp range 7.5-30 7.5-25 7.5-50 7.5-50 5-20 5-20 Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 2.44 2.00 2.19 1.69 n/a n/a 114 CLCH-PRC022A-EN General Data Unit Size 36 Table 85. Section dimensions (inches) and weights (pounds) - unit size 36 Nominal airflow 18,000 Airflow at 625 fpm 25,000 Height - indoor unit (in.) Width (in.) Height - outdoor unit (in.) includes base drip lip 89.00 80.00 Available for indoor use only n/a n/a Length (in.) Weight (lb.) -Small horizontal 10.00 207.98 -Medium horizontal 14.00 238.68 -Extended-medium horizontal 19.00 277.04 Weight add for outdoor unit (lbs./in. of unit length) Section type Access or blank -Medium-large horizontal 29.50 319.24 -Large horizontal or turning 46.00 509.00 -Extra-large horizontal or turning n/a n/a -Ducted inlet or ducted outlet section 10.00 208.00 Blender 40.00 495.07 n/a n/a Cool Dry Quiet (CDQ) Desiccant Dehumidification Section Coils -Small horizontal (with 4-row UW) 10.00 675.23 -Medium horizontal (with 8-row UW) 14.00 1095.29 1138.74 -Extended-medium horizontal (with 8-row UW) 19.00 -Medium-large horizontal (with 10-row W) 29.50 2017.86 -Large horizontal or vertical (with 10-row W) 46.00 2161.23 n/a n/a -Integral-face-and-bypass (IFB) coil --Less than 4 rows 29.50 1407.86 --4 rows 43.00 2148.28 Controls section (includes largest available VFD) 28.50 649.00 Diffuser 24.50 316.89 -Electric Heat Coil Discharge plenum -Horizontal 46.00 621.68 -Vertical n/a n/a Energy Wheel n/a n/a Face-and-Bypass Dampers -Face-and-bypass 19.00 274.69 -External face-and-bypass 27.75 341.83 -Internal face-and-bypass or face damper only 19.00 274.69 Fan -Belt-drive plenum (BDP) fan with motor n/a n/a -Housed fan FC with motor 80.50 2423.46 -Housed AF/BC fans with motor 80.50 2568.99 -Direct-drive plenum fan with motor 80.50 2804.47 -Side load 2-in. angled 24.50 562.37 -Side load 4-in. angled 24.50 567.56 -Side load cartridge 12-in. or short bag 18-in. 24.50 637.25 Filters CLCH-PRC022A-EN 115 General Data Table 85. Section dimensions (inches) and weights (pounds) - unit size 36 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 14.00 322.85 -Side load 4-in. flat 14.00 350.39 -Side load 2-in. and 4-in. combination flat 19.00 484.13 -Long bag 30-in. 37.25 701.00 -Front-load HEPA 40.00 1176.00 -Front-load cartridge 40.00 797.00 -Front-load short bag 45.00 778.00 n/a n/a -Building Steam 14.00 622.00 -Atmospheric 19.00 508.00 46.00 513.70 n/a n/a Gas heat Humidifier Mixing box -with angled filters -with front/back Traq and top Traq dampers - reduced length mixing box with side/top/back/bottom airfoil damper n/a n/a Multizone n/a n/a Silencer -3 feet 38.00 951.00 -5 feet 62.00 1478.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 916.00 n/a n/a UV light Table 86. Filter data for unit size 36 Filter Type Area (ft²) Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 37.22 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 63.33 Side load bag or cartridge 34.67 Front load bag or cartridge 34.00 Front load HEPA 30.00 Qty–Size (in.) 8 - 20x24 3 - 16x25 1 - 16x20 18 - 16x25 6 - 16x20 8 - 20x24 4 - 12x24 5 - 12x24 6 - 24x24 3 - 24x30 3 - 30x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 87. Coil availability - size 36 Section Type Small Medium 116 1/2-in Unit Coils 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils 2 rows 1-2 rows 2–6 rows (4 row cooling) 1–4 rows without IDP Extended-medium 2–8 rows 1-8 rows without IDP Medium-large 2-8 rows 1-10 rows -with access 2–8 rows 1–6 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–10 rows Large vertical n/a n/a -with access n/a n/a CLCH-PRC022A-EN General Data Table 88. Coil data for unit size 36 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 2, 4, 6, 8 Aluminum 34.11 1–37.50 × 65.50 1, 2, 3, 4, 6, 8 Aluminum or Copper 34.38 2-37.50 x 66 10 Aluminum 34.38 2-37.50 x 66 1 Aluminum or Copper 31.63 1-33 x 66 2-18 x 66 2, 4, 6, 8 Aluminum 26.93 1-33.75 x 66 1-25 x 66 1, 2, 3, 4, 6, 8 Aluminum or Copper 26.13 4, 6, 8, 10 Aluminum 26.13 1 Aluminum or Copper 26.13 1/2-inch unit coils -UW, UA, UF, UU (stacked) 5/8-inch unit coils -W, WD, 5A, 5W, D1, D2 (stacked) - W, WD, D1, D2 (stacked) 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL, FD (stacked) 5/8-inch modified coils -W, 5A, 5W, D1, D2 (stacked) -W, WD, D1, D2 (stacked) 1-33 1-24 1-33 1-24 x x x x 66 66 66 66 1-inch modified coil -NS (stacked) Multizone coils n/a 1-33 x 66 1- 24 x 66 n/a Table 89. Fan data for unit size 36 Housed Fans - Low Pressure Size/Type 25-in. FC 22-in. FC 20-in. FC 25-in. AF 22-in. AF 20-in. AF Fan name 25FA 22FA 20FA 25AA 22AA 20AA Max rpm 850 950 1050 1650 1900 2300 ODP NEMA Premium motor hp range 7.5-20 7.5-20 7.5-20 7.5-20 7.5-15 7.5-15 Outlet area (ft²) 6.95 5.54 4.38 6.95 5.54 4.38 Bearing/Shaft size (in.) 1.69 1.50 1.50 1.69 1.50 1.50 Size/Type 25-in. FC 22-in. FC 20-in. FC 25-in. AF 22-in. AF 20-in. AF Fan name 25FB 22FB 20FB 25AB 22AB 20AB Max rpm 1025 1200 1330 2200 2500 2750 ODP NEMA Premium motor hp range 7.5-40 7.5-30 7.5-25 7.5-40 7.5-40 7.5-30 Outlet area (ft²) 6.95 5.54 4.38 6.95 5.54 4.38 Bearing/Shaft size (in.) 2.44 2.00 1.69 2.00 2.00 1.69 Housed Fans - High Pressure Belt-drive Plenum Fans Low Pressure Size/Type n/a n/a Direct-Drive Plenum Fans High Pressure n/a n/a High Pressure 2- 22-in AF 2- 22-in AF Nominal Width Extended Width Fan name 22SF 22SW Max rpm 2675 2675 ODP NEMA Premium motor hp range 5-25 5-25 Outlet area (ft²) n/a n/a Bearing/Shaft size (in.) n/a n/a CLCH-PRC022A-EN 117 General Data Unit Size 40 Table 90. Section dimensions (inches) and weights (pounds) - unit size 40 Nominal airflow 20,000 Airflow at 625 fpm 25,519 Height - indoor unit (in.) Width (in.) Height - outdoor unit (in.) includes base drip lip Weight add for outdoor unit (lbs./in. of unit length) Section type 67.25 112.50 75.00 3.28 Length (in.) Weight (lb.) -Small horizontal 10.00 227.92 -Medium horizontal 14.00 260.24 -Extended-medium horizontal 19.00 300.64 Access or blank -Medium-large horizontal 24.50 345.09 -Large horizontal or turning 48.00 557.22 -Extra-large horizontal or turning 63.75 675.12 -Ducted inlet or ducted outlet section 10.00 227.90 Blender 48.00 593.46 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section 56.00 3122.00 Coils -Small horizontal (with 4-row UW) 10.00 754.61 -Medium horizontal (with 8-row UW) 14.00 1219.78 1279.06 -Extended-medium horizontal (with 8-row UW) 19.00 -Medium-large horizontal (with 10-row W) 24.50 2216.68 -Large horizontal or vertical (with 10-row W) 48.00 2401.84 -Electric Heat Coil 63.80 1825.00 -Integral-face-and-bypass (IFB) coil --Less than 4 rows 29.50 1168.40 --4 rows 43.00 1720.20 Controls section (includes largest available VFD) 28.50 674.00 Diffuser 24.50 342.74 -Horizontal 48.00 677.47 -Vertical 63.75 949.58 Energy Wheel 65.00 2742.00 Discharge plenum Face-and-Bypass Dampers -Face-and-bypass 19.00 556.23 -External face-and-bypass 22.00 660.36 -Internal face-and-bypass or face damper only 19.00 575.62 -Belt-drive plenum (BDP) fan with motor 53.50 2740.37 -Housed fan FC with motor 63.75 2603.08 -Housed AF/BC fans with motor 63.75 2695.61 -Direct-drive plenum fan with motor 63.75 2406.73 -Side load 2-in. angled 24.50 649.06 -Side load 4-in. angled 24.50 631.64 -Side load cartridge 12-in. or short bag 18-in. 24.50 668.25 Fan Filters 118 CLCH-PRC022A-EN General Data Table 90. Section dimensions (inches) and weights (pounds) - unit size 40 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 14.00 358.18 -Side load 4-in. flat 14.00 375.13 -Side load 2-in. and 4-in. combination flat 19.00 504.37 -Long bag 30-in. 37.25 716.00 -Front-load HEPA 40.00 1128.00 -Front-load cartridge 40.00 923.00 -Front-load short bag 45.00 800.00 Gas heat - 200 MBH n/a n/a - 300 MBH n/a n/a - 360 MBH n/a n/a - 560 MBH 64.00 1468.10 - 700 MBH 75.00 1804.10 - 860 MBH 75.00 2098.70 - 1000 MBH 81.00 1844.70 105.00 2717.90 -Building Steam 14.00 599.00 -Atmospheric 19.00 665.00 - 1250-1750 MBH Humidifier Mixing box -with angled filters 48.00 561.92 -with front/back Traq and top Traq dampers 63.75 1073.80 - reduced length mixing box with side/top/back/bottom airfoil damper 38.50 795.10 92.00 4732.00 Multizone - 3-deck vertical discharge - 2-deck vertical discharge 92.00 3267.00 - 3-deck horizontal discharge 78.00 4471.00 - 2-deck horizontal discharge 78.00 3006.00 Silencer -3 feet 38.00 974.00 -5 feet 62.00 1439.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 935.00 UV light 14.00 352.71 SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 83.00 1062.00 -with airfoil damper and one side Traq damper 83.00 1101.00 Exhaust damper section 24.50 489.90 - Back inlet hood - airfoil and Traq 112.38 195.00 - Side inlet hood - airfoil and Traq 40.88 128.00 - Exhaust hood - airfoil 40.88 77.00 - Economizer inlet hood 83.00 275.00 15 in. long - 24-in. depth 15.00 130.00 15 in. long - 36-in. depth 15.00 175.00 15 in. long - 48-in. depth 15.00 220.00 Hoods Pipe Cabinets CLCH-PRC022A-EN 119 General Data Table 90. Section dimensions (inches) and weights (pounds) - unit size 40 Pipe Cabinets Length (in.) Weight (lb.) 24 in. long - 24-in. depth 24.00 151.00 24 in. long - 36-in. depth 24.00 199.00 24 in. long - 48-in. depth 24.00 247.00 207.00 48 in. long - 24-in. depth 48.00 48 in. long - 36-in. depth 48.00 263.00 48 in. long - 48-in. depth 48.00 320.00 319.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 392.00 96 in. long - 48-in. depth 96.00 466.00 Table 91. Filter data for unit size 40 Filter Type Area ft² Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 40.83 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 70.00 Side load bag or cartridge 36.00 Front load bag or cartridge 40.00 Front load HEPA 37.00 Qty–Size (in.) 8 - 20x20 2 - 20x25 4 - 16x20 1 - 16x25 6 - 16x25 24 - 16x20 8 - 24x24 2 - 24x12 4 - 12x24 8 - 24x24 3 - 24x30 1 - 24x12 4 - 30x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 92. Coil availability - size 40 Section Type 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils Small 2-4 rows 1-2 rows Medium 2–8 rows 1–4 rows Extended-medium 2–8 rows 1–81 rows Medium-large 2-8 rows 1-10 rows -with access 2–4 rows 1–3 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–10 rows Large vertical 2-8 rows 1–6 rows -with access 2–8 rows 1–6 rows Note: 120 1/2-in Unit Coils 16-row maximum for stacked coils. CLCH-PRC022A-EN General Data Table 93. Coil data for unit size 40 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 2, 4, 6, 8 Aluminum 39.93 1–57.50 × 100 1/2-inch unit coils -UA, UW, UF, UU 5/8-inch unit coils -W, WD, D1, D2 4, 6, 8 Aluminum or Copper 38.54 1-55.50 x 100 6, 8, 10 Aluminum 38.54 1-55.50 x 100 1, 2, 3 Aluminum or Copper 37.50 1-54 x 100 1 Aluminum or Copper 35.42 1-33 x 100 1-18 x 100 2, 4, 6, 8 Aluminum 25.17 1-36.25 x 100 1, 2, 3, 4, 6, 8 Aluminum or Copper 25.00 1-36 x 100 10 Aluminum 25.00 1-36 x 100 1 Aluminum or Copper 25.00 2-18 x 100 1, 2 Aluminium or Copper 20.83 1-30 x 100 2 Aluminum 20.83 1-30 x 100 -W, WD, 5D, D1, D2 -W, 5A, 5W, D1 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL, FD 5/8-inch modified coils -W, WD, 5A, 5W, D1, D2 -W, WD, D1, D2 1-inch modified coil -NS (stacked) Multizone coils -5A, 5W, NS -WL Table 94. Fan data for unit size 40 Housed Fans - Low Pressure Size/Type 28-in. FC 25-in. FC 22-in. FC 28-in. AF 25-in. AF 22-in. AF Fan name 28FA 25FA 22FA 28AA 25AA 22AA Max rpm 750 850 950 1500 1650 1900 ODP NEMA Premium motor hp range 7.5-25 7.5-20 7.5-20 7.5-20 7.5-20 7.5-15 Outlet area (ft²) 8.81 6.95 5.54 8.81 6.95 5.54 Bearing/Shaft size (in.) 1.94 1.69 1.50 1.94 1.69 1.50 Size/Type 28-in. FC 25-in. FC 22-in. FC 28-in. AF 25-in. AF 22-in. AF Fan name 28FB 25FB 22FB 28AB 25AB 22AB Max rpm 860 1025 1200 2050 2200 2500 ODP NEMA Premium motor hp range 7.5-40 7.5-40 7.5-30 7.5-50 7.5-50 7.5-50 Outlet area (ft²) 8.81 6.95 5.54 8.81 6.95 5.54 Bearing/Shaft size (in.) 2.44 2.44 2.00 2.19 2.00 2.00 High Pressure - High Pressure Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 2-27-in AF 2- 27-in AF Reduced Width Nominal Width Size/Type 40-in. AF 36-in. AF 40-in. AF 36-in. AF Fan name 40PA 36PA 40PB 36PB 27NR Max rpm 1150 1350 1400 1600 2035 2035 ODP NEMA Premium motor hp range 7.5-30 7.5-30 7.5-50 7.5-50 5-20 7.5-25 27NF Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 2.44 2.44 2.19 2.19 n/a n/a CLCH-PRC022A-EN 121 General Data Unit Size 41 Table 95. Section dimensions (inches) and weights (pounds) - unit size 41 Nominal airflow 20,500 Airflow at 625 fpm 30,138 Height - indoor unit (in.) 104.00 Width (in.) Height - outdoor unit (in.) includes base drip lip 80.00 Available for indoor use only n/a n/a Length (in.) Weight (lb.) -Small horizontal 10.00 224.38 -Medium horizontal 14.00 257.35 -Extended-medium horizontal 19.00 298.56 Weight add for outdoor unit (lbs./in. of unit length) Section type Access or blank -Medium-large horizontal 29.50 343.89 -Large horizontal or turning 46.00 561.11 -Extra-large horizontal or turning n/a n/a -Ducted inlet or ducted outlet section 10.00 224.40 Blender 48.00 616.31 n/a n/a Cool Dry Quiet (CDQ) Desiccant Dehumidification Section Coils -Small horizontal (with 4-row UW) 10.00 792.51 -Medium horizontal (with 8-row UW) 14.00 1290.73 1337.01 -Extended-medium horizontal (with 8-row UW) 19.00 -Medium-large horizontal (with 10-row W) 29.50 2355.51 -Large horizontal or vertical (with 10-row W) 46.00 2508.26 n/a n/a -Integral-face-and-bypass (IFB) coil --Less than 4 rows 29.50 1449.00 --4 rows 43.00 2196.84 Controls section (includes largest available VFD) 28.50 698.00 Diffuser 24.50 341.54 -Electric Heat Coil Discharge plenum -Horizontal 46.00 682.71 -Vertical n/a n/a Energy Wheel n/a n/a Face-and-Bypass Dampers -Face-and-bypass 19.00 296.21 -External face-and-bypass 27.75 368.32 -Internal face-and-bypass or face damper only 19.00 296.21 Fan -Belt-drive plenum (BDP) fan with motor n/a n/a -Housed fan FC with motor 80.50 2771.01 -Housed AF/BC fans with motor 80.50 2863.54 -Direct-drive plenum fan with motor 80.50 3039.54 -Side load 2-in. angled 24.50 652.32 -Side load 4-in. angled 24.50 663.25 -Side load cartridge 12-in. or short bag 18-in. 24.50 762.69 Filters 122 CLCH-PRC022A-EN General Data Table 95. Section dimensions (inches) and weights (pounds) - unit size 41 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 14.00 358.29 -Side load 4-in. flat 14.00 404.69 -Side load 2-in. and 4-in. combination flat 19.00 570.61 -Long bag 30-in. 37.25 803.00 -Front-load HEPA 40.00 1268.00 -Front-load cartridge 40.00 931.00 -Front-load short bag 45.00 885.00 n/a n/a -Building Steam 14.00 684.00 -Atmospheric 19.00 570.00 46.00 565.81 n/a n/a Gas heat Humidifier Mixing box -with angled filters -with front/back Traq and top Traq dampers - reduced length mixing box with side/top/back/bottom airfoil damper n/a n/a Multizone n/a n/a -3 feet 38.00 1013.00 -5 feet 62.00 1558.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 946.00 n/a n/a Silencer UV light Table 96. Filter data for unit size 41 Filter Type Area ft² Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 40.83 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 70.00 Side load bag or cartridge 36.00 Front load bag or cartridge 40.00 Front load HEPA 37.00 Qty–Size (in.) 8 - 20x20 2 - 20x25 4 - 16x20 1 - 16x25 6 - 16x25 24 - 16x20 8 - 24x24 2 - 24x12 4 - 12x24 8 - 24x24 3 - 24x30 1 - 24x12 4 - 30x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 97. Coil availability - size 41 Section Type Small Medium CLCH-PRC022A-EN 1/2-in Unit Coils 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils 2 rows 1-2 rows 2–6 rows (4 row cooling) 1–4 rows without IDP Extended-medium 2–8 rows 1–8 rows without IDP Medium-large 2-8 rows 1-10 rows -with access 2–8 rows 1–6 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–10 rows Large vertical n/a n/a -with access n/a n/a 123 General Data Table 98. Coil data for unit size 41 Coil Type Rows Fin Type Area ft² 2, 4, 6, 8 Aluminum 40.94 Qty–Size (in.) 1/2-inch unit coils -UA, UW, UF, UU (stacked) 2–45 x 65.50 5/8-inch unit coils -W, WD, 5A, 5W, D1, D2 (stacked) 1, 2, 3, 4, 6, 8, 10 -W, 5D (stacked) 6, 8, 10 Aluminum or Copper Aluminum 41.25 2-45 x 66 41.25 2-45 x 66 38.50 2-30 x 66 1-24 x 66 33.23 2-36.25 x 66 33.00 2-36 x 66 33.00 2-36 x 66 23.38 2-18 x 66 1-33 x 66 1-inch unit coil -NS (stacked) 1 Aluminum or Copper 1/2-inch modified coils -WL, LL, FD (stacked) 2, 4, 6, 8 Aluminum 5/8-inch modified coils -W, WD, 5A, 5W, D1, D2 1, 2, 3, 4, 6, 8 -W, WD, D1, D2 Aluminum or Copper 10 Aluminum 1-inch modified coil -NS (stacked) 1 Aluminum or Copper Multizone coils n/a n/a Table 99. Fan data for unit size 41 Housed Fans - Low Pressure Size/Type 28-in. FC 25-in. FC 22-in. FC 28-in. AF 25-in. AF 22-in. AF Fan name 28FA 25FA 22FA 28AA 25AA 22AA Max rpm 750 850 950 1500 1650 1900 ODP NEMA Premium motor hp range 7.5-25 7.5-20 7.5-20 7.5-20 7.5-20 7.5-15 Outlet area (ft²) 8.81 6.95 5.54 8.81 6.95 5.54 Bearing/Shaft size (in.) 1.94 1.69 1.50 1.94 1.69 1.50 Housed Fans - High Pressure Size/Type 28-in. FC 25-in. FC 22-in. FC 28-in. AF 25-in. AF 22-in. AF Fan name 28FB 25FB 22FB 28AB 25AB 22AB Max rpm 860 1025 1200 2050 2200 2500 ODP NEMA Premium motor hp range 7.5-40 7.5-40 7.5-30 7.5-50 7.5-50 7.5-50 Outlet area (ft²) 8.81 6.95 5.54 8.81 6.95 5.54 Bearing/Shaft size (in.) 2.44 2.44 2.00 2.19 2.00 2.00 Belt-drive Plenum Fans Low Pressure Size/Type n/a n/a Direct-Drive Plenum Fans High Pressure n/a n/a High Pressure 2-24-in AF 2-24.5-in AF Nominal Width Extended Width Fan name 24SF 24SW Max rpm 2365 2365 ODP NEMA Premium motor hp range 5-25 5-25 Outlet area (ft²) n/a n/a Bearing/Shaft size (in.) n/a n/a 124 CLCH-PRC022A-EN General Data Unit Size 50 Table 100. Section dimensions (inches) and weights (pounds) - unit size 50 Nominal airflow 25,000 Airflow at 625 fpm 34,375 Height - indoor unit (in.) Width (in.) Height - outdoor unit (in.) includes base drip lip Weight add for outdoor unit (lbs./in. of unit length) Section type 75.75 125.50 84.38 3.73 Length (in.) Weight (lb.) -Small horizontal 10.00 254.69 -Medium horizontal 14.00 290.28 -Extended-medium horizontal 19.00 334.76 Access or blank -Medium-large horizontal 24.50 410.37 -Large horizontal or turning 48.00 639.24 -Extra-large horizontal or turning 68.50 809.42 -Ducted inlet or ducted outlet section 10.00 254.70 Blender 48.00 675.51 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section 59.00 4224.00 Coils -Small horizontal (with 4-row UW) 10.00 934.27 -Medium horizontal (with 8-row UW) 14.00 1561.92 1613.56 -Extended-medium horizontal (with 8-row UW) 19.00 -Medium-large horizontal (with 10-row W) 24.50 2754.49 -Large horizontal or vertical (with 10-row W) 48.00 2985.19 -Electric Heat Coil 68.50 2267.00 -Integral-face-and-bypass (IFB) coil --Less than 4 rows 29.50 1793.80 --4 rows n/a n/a Controls section (includes largest available VFD) 28.50 745.00 Diffuser 24.50 381.33 Discharge plenum -Horizontal 48.00 772.27 -Vertical 68.50 1136.53 Energy Wheel 65.00 3111.00 Face-and-Bypass Dampers -Face-and-bypass 19.00 630.10 -External face-and-bypass 22.00 740.29 -Internal face-and-bypass or face damper only 19.00 678.20 -Belt-drive plenum (BDP) fan with motor 57.50 3263.68 -Housed fan FC with motor 68.50 3151.89 -Housed AF/BC fans with motor 68.50 3221.42 -Direct-drive plenum fan with motor 68.50 3469.95 -Side load 2-in. angled 27.50 770.02 -Side load 4-in. angled 27.50 768.20 -Side load cartridge 12-in. or short bag 18-in. 27.50 878.57 Fan Filters CLCH-PRC022A-EN 125 General Data Table 100. Section dimensions (inches) and weights (pounds) - unit size 50 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 14.00 408.69 -Side load 4-in. flat 14.00 451.33 -Side load 2-in. and 4-in. combination flat 19.00 600.40 -Long bag 30-in. 37.25 827.00 -Front-load HEPA 40.00 1397.00 -Front-load cartridge 40.00 1093.00 -Front-load short bag 45.00 917.00 Gas heat - 200 MBH n/a n/a - 300 MBH n/a n/a - 360 MBH n/a n/a - 560 MBH 64.00 1853.50 - 700 MBH 74.00 2190.50 - 860 MBH 74.00 2280.50 77.00 2325.60 - 1000 MBH - 1250-1750 MBH 106.00 3264.80 - 2000 MBH 114.00 3758.70 -Building Steam 14.00 782.00 -Atmospheric 19.00 724.00 Humidifier Mixing box -with angled filters 48.00 653.36 -with front/back Traq and top Traq dampers 68.50 1261.78 -reduced length mixing box with side/top/back/bottom airfoil damper 41.50 947.60 - 3-deck vertical discharge 96.00 5739.00 - 2-deck vertical discharge 96.00 3986.00 - 3-deck horizontal discharge 78.00 5276.00 - 2-deck horizontal discharge 78.00 3633.00 -3 feet 38.00 1226.00 -5 feet 62.00 1795.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 1044.00 UV light 14.00 394.34 Multizone Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 72.00 1120.00 -with airfoil damper and one side Traq damper 72.00 1169.00 Exhaust damper section 24.50 565.60 - Back inlet hood - airfoil and Traq 125.38 230.00 - Side inlet hood - airfoil and Traq 44.75 161.00 - Exhaust hood - airfoil 39.63 93.00 - Economizer inlet hood 72.00 358.00 Hoods 126 CLCH-PRC022A-EN General Data Table 100. Section dimensions (inches) and weights (pounds) - unit size 50 Pipe Cabinets Length (in.) Weight (lb.) 15 in. long - 24-in. depth 15.00 142.00 15 in. long - 36-in. depth 15.00 191.00 15 in. long - 48-in. depth 15.00 239.00 164.00 24 in. long - 24-in. depth 24.00 24 in. long - 36-in. depth 24.00 216.00 24 in. long - 48-in. depth 24.00 268.00 224.00 48 in. long - 24-in. depth 48.00 48 in. long - 36-in. depth 48.00 284.00 48 in. long - 48-in. depth 48.00 345.00 344.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 421.00 96 in. long - 48-in. depth 96.00 498.00 Table 101. Filter data for unit size 50 Filter Type Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media Angled (2-in. or 4-in.) Pleated, permanent, throwaway media Area (ft²) Qty–Size (in.) 55.00 12 - 25x20 4 - 16x25 1 - 16x20 100.00 36 - 20x20 Side load bag or cartridge 50.00 Front load bag or cartridge 50.00 Front load HEPA 46.00 10 - 24x24 5 - 12x24 5 - 12x24 10 - 24x24 3 - 24x30 1 - 24x24 3 - 24x30 1 - 24x24 4 - 12x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 102.Coil availability - size 50 Section Type Small CLCH-PRC022A-EN 1/2-in Unit Coils 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils 2 rows 1-2 rows Medium 2–4 rows 1–3 rows Extended-medium 2–8 rows 1-6 rows Medium-large 2-8 rows 1-8 rows -with access 2-4 rows n/a Large horizontal 2–8 rows 1–8 rows -with access 2–8 rows 1–10 rows Large vertical 2-8 rows 1–6 rows -with access 2–8 rows 1–6 rows 127 General Data Table 103.Coil data for unit size 50 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 2, 4, 6, 8 Aluminum 49.05 -W, WD, D1, D2 (stacked) 4, 6, 8, 10 Aluminum 48.26 -W, WD, D1, D2 (stacked) 4, 6, 8 Copper 48.26 -W, 5A, 5W, D1 (stacked) 1, 2, 3 Aluminum or Copper 47.08 1 Aluminum or Copper 47.08 2-30 x 113 2, 4, 6, 8 Aluminum 33.35 1-42.50 x 113 1, 2, 3, 4, 6, 8, 10 Aluminum or Copper 35.31 1-45 x 113 1 Aluminum or Copper 32.96 1-24 x 113 1-18 x 113 1, 2 Aluminium or Copper 25.90 1-33 x 113 2 Aluminum 25.90 1-33 x 113 1/2-inch unit coils -UA, UW, UF, UU (stacked) 2-31.25 x 113 5/8-inch unit coils 1-27 1-34.50 1-27 1-34.50 1-27 1-33 x x x x x x 113 113 113 113 113 113 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL, FD 5/8-inch modified coils -W, WD, 5A, 5W, D1, D2 1-inch modified coil -NS (stacked) Multizone coils -5A, 5W, NS -WL Table 104.Fan data for unit size 50 Housed Fans - Low Pressure Size/Type 32-in. FC 28-in. FC 25-in. FC 32-in. AF 28-in. AF 25-in. AF Fan name 32FA 28FA 25FA 32AA 28AA 25AA Max rpm 675 750 850 1300 1500 1650 ODP NEMA Premium motor hp range 7.5-30 7.5-25 7.5-20 7.5-30 7.5-20 7.5-20 Outlet area (ft²) 11.11 8.81 6.95 11.11 8.81 6.95 Bearing/Shaft size (in.) 2.19 1.94 1.69 2.19 1.94 1.69 Size/Type 32-in. FC 28-in. FC 25-in. FC 32-in. AF 28-in. AF 25-in. AF Fan name 32FB 28FB 25FB 32AB 28AB 25AB Max rpm 760 860 1025 1700 2050 2200 ODP NEMA Premium motor hp range 7.5-50 7.5-40 7.5-40 7.5-60 7.5-60 7.5-50 Outlet area (ft²) 11.11 8.81 6.95 11.11 8.81 6.95 Bearing/Shaft size (in.) 2.19 2.44 2.44 2.19 2.19 2.00 Housed Fans - High Pressure Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 2-30-in AF 2-30-in AF Reduced Width Nominal Width Size/Type 40-in. AF 36-in. AF 40-in. AF 36-in. AF Fan name 40PA 36PA 40PB 36PB 30NR Max rpm 1150 1350 1400 1600 1851 1851 ODP NEMA Premium motor hp range 7.5-30 7.5-30 7.5-75 7.5-60 10-30 10-30 128 30NF Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 2.44 2.44 2.19 2.19 n/a n/a CLCH-PRC022A-EN General Data Unit Size 51 Table 105. Section dimensions (inches) and weights (pounds) - unit size 51 Nominal airflow 25,500 Airflow at 625 fpm 34,306 Height - indoor unit (in.) 104.00 Width (in.) Height - outdoor unit (in.) includes base drip lip 93.50 Available for indoor use only n/a n/a Length (in.) Weight (lb.) -Small horizontal 10.00 242.54 -Medium horizontal 14.00 277.55 -Extended-medium horizontal 19.00 321.32 Weight add for outdoor unit (lbs./in. of unit length) Section type Access or blank -Medium-large horizontal 29.50 369.46 -Large horizontal or turning 46.00 615.72 -Extra-large horizontal or turning n/a n/a -Ducted inlet or ducted outlet section 10.00 242.50 Blender 48.00 656.33 n/a n/a Cool Dry Quiet (CDQ) Desiccant Dehumidification Section Coils -Small horizontal (with 4-row UW) 10.00 922.65 -Medium horizontal (with 8-row UW) 14.00 1523.08 1572.75 -Extended-medium horizontal (with 8-row UW) 19.00 -Medium-large horizontal (with 10-row W) 29.50 2791.28 -Large horizontal or vertical (with 10-row W) 46.00 2955.21 n/a n/a 29.50 1640.15 -Electric Heat Coil -Integral-face-and-bypass (IFB) coil --Less than 4 rows --4 rows n/a n/a Controls section (includes largest available VFD) 28.50 747.00 Diffuser 24.50 367.11 Discharge plenum -Horizontal 46.00 745.34 -Vertical n/a n/a Energy Wheel n/a n/a Face-and-Bypass Dampers -Face-and-bypass 19.00 318.97 -External face-and-bypass 27.75 395.56 -Internal face-and-bypass or face damper only 19.00 318.97 Fan -Belt-drive plenum (BDP) fan with motor n/a n/a -Housed fan FC with motor 88.00 3312.75 -Housed AF/BC fans with motor 88.00 3382.28 -Direct-drive plenum fan with motor 88.00 4268.88 -Side load 2-in. angled 24.50 688.86 -Side load 4-in. angled 24.50 747.25 -Side load cartridge 12-in. or short bag 18-in. 24.50 874.81 Filters CLCH-PRC022A-EN 129 General Data Table 105. Section dimensions (inches) and weights (pounds) - unit size 51 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 14.00 392.33 -Side load 4-in. flat 14.00 461.82 -Side load 2-in. and 4-in. combination flat 19.00 646.20 -Long bag 30-in. 37.25 883.00 -Front-load HEPA 40.00 1450.00 -Front-load cartridge 40.00 1062.00 -Front-load short bag 45.00 969.00 n/a n/a -Building Steam 14.00 773.00 -Atmospheric 19.00 683.00 46.00 629.45 n/a n/a Gas heat Humidifier Mixing box -with angled filters -with front/back Traq and top Traq dampers - reduced length mixing box with side/top/back/bottom airfoil damper n/a n/a Multizone n/a n/a -3 feet 38.00 1142.00 -5 feet 62.00 1759.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 1044.00 n/a n/a Silencer UV light Table 106.Filter data for unit size 51 Filter Type Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media Angled (2-in. or 4-in.) Pleated, permanent, throwaway media Area ft² Qty–Size (in.) 55.00 12 - 25x20 4 - 16x25 1 - 16x20 100.00 36 - 20x20 Side load bag or cartridge 50.00 Front load bag or cartridge 50.00 Front load HEPA 46.00 10 - 24x24 5 - 12x24 5 - 12x24 10 - 24x24 3 - 24x30 1 - 24x24 3 - 24x30 1 - 24x24 4 - 12x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 107. Coil availability - size 51 Section Type Small Medium 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils 2 rows 1-2 rows 2–6 rows (4 row cooling) 1–4 rows without IDP Extended-medium 2–8 rows 1-8 rows without IDP Medium-large 2-8 rows 1-10 rows -with access 2-8 rows 1-6 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–10 rows n/a n/a Large vertical 130 1/2-in Unit Coils CLCH-PRC022A-EN General Data Table 108.Coil data for unit size 51 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 2, 4, 6, 8 Aluminum 50.00 2-45 x 80 1, 2, 3, 4, 6, 8, 10 Aluminum or Copper 50.00 2-45 x 80 6, 8, 10 Aluminum 50.00 2-45 x 80 1 Aluminum or Copper 46.67 2-30 x 80 1-24 x 80 2, 4, 6, 8 Aluminum 40.28 2-36.25 x 80 1, 2, 3, 4, 6, 8 Aluminum or Copper 40.00 2-36 x 80 10 Aluminum 40.00 2-36 x 80 1 Aluminum or Copper 38.33 2-18 x 80 1-33 x 80 1/2-inch unit coils -UA, UW, UF, UU (stacked) 5/8-inch unit coils -W, WD, 5A, 5W, D1, D2 (stacked) -W, WD, 5D, D1, D2 (stacked) 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL, FD (stacked) 5/8-inch modified coils -W, WD, 5A, 5W, D1, D2 (stacked) -W, WD, D1, D2 (stacked) 1-inch modified coil -NS (stacked) Multizone coils n/a n/a Table 109.Fan data for unit size 51 Housed Fans - Low Pressure Size/Type 32-in. FC 28-in. FC 25-in. FC 32-in. AF 28-in. AF 25-in. AF Fan name 32FA 28FA 25FA 32AA 28AA 25AA 675 750 850 1300 1500 1650 ODP NEMA Premium motor hp range 7.5-30 7.5-25 7.5-20 7.5-30 7.5-20 7.5-20 Outlet area (ft²) 11.11 8.81 6.95 11.11 8.81 6.95 2.19 1.94 1.69 2.19 1.94 1.69 Size/Type 32-in. FC 28-in. FC 25-in. FC 32-in. AF 28-in. AF 25-in. AF Fan name 32FB 28FB 25FB 32AB 28AB 25AB 760 860 1025 1700 2050 2200 ODP NEMA Premium motor hp range 7.5-50 7.5-40 7.5-40 7.5-60 7.5-60 7.5-50 Outlet area (ft²) 11.11 8.81 6.95 11.11 8.81 6.95 2.19 2.44 2.44 2.19 2.19 2.00 Max rpm Bearing/Shaft size (in.) Housed Fans - High Pressure Max rpm Bearing/Shaft size (in.) Belt-drive Plenum Fans Low Pressure Size/Type Fan name n/a n/a Direct-Drive Plenum Fans High Pressure n/a n/a High Pressure 4- 22-in AF 4- 22-in AF Reduced Width Nominal Width 22SR 22SF Max rpm 2675 2675 ODP NEMA Premium motor hp range 3-20 3-20 Outlet area (ft²) n/a n/a Bearing/Shaft size (in.) n/a n/a CLCH-PRC022A-EN 131 General Data Unit Size 57 Table 110. Section dimensions (inches) and weights (pounds) - unit size 57 Nominal airflow 28,500 Airflow at 625 fpm 39,581 Height - indoor unit (in.) Width (in.) Height - outdoor unit (in.) includes base drip lip Weight add for outdoor unit (lbs./in. of unit length) Section type 85.50 125.50 94.13 6.12 Length (in.) Weight (lb.) -Small horizontal 10.00 265.35 -Medium horizontal 14.00 302.41 -Extended-medium horizontal 19.00 348.74 Access or blank -Medium-large horizontal 24.50 427.50 -Large horizontal or turning 48.00 682.26 -Extra-large horizontal or turning n/a n/a -Ducted inlet or ducted outlet section 10.00 265.30 Blender 48.00 731.75 n/a n/a -Small horizontal (with 4-row UW) 10.00 1044.33 -Medium horizontal (with 8-row UW) 14.00 1759.58 -Extended-medium horizontal (with 8-row UW) 19.00 1813.06 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section Coils -Medium-large horizontal (with 10-row W) 24.50 3215.01 -Large horizontal or vertical (with 10-row W) 48.00 3454.40 -Electric Heat Coil 48.00 2297.00 -Integral-face-and-bypass (IFB) coil --Less than 4 rows 29.50 1956.80 --4 rows n/a n/a Controls section (includes largest available VFD) 28.50 787.00 Diffuser 24.50 397.35 Discharge plenum -Horizontal 48.00 821.10 -Vertical n/a n/a Energy Wheel n/a n/a Face-and-Bypass Dampers -Face-and-bypass 19.00 714.61 -External face-and-bypass 22.00 831.66 -Internal face-and-bypass or face damper only 19.00 714.61 -Belt-drive plenum (BDP) fan with motor 59.50 3599.82 -Housed fan FC with motor 68.50 3235.63 -Housed AF/BC fans with motor 68.50 3305.16 -Direct-drive plenum fan with motor 68.50 3545.86 -Side load 2-in. angled 27.50 797.89 -Side load 4-in. angled 27.50 805.97 -Side load cartridge 12-in. or short bag 18-in. 27.50 934.14 Fan Filters 132 CLCH-PRC022A-EN General Data Table 110. Section dimensions (inches) and weights (pounds) - unit size 57 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 14.00 438.52 -Side load 4-in. flat 14.00 498.71 -Side load 2-in. and 4-in. combination flat 19.00 671.64 -Long bag 30-in. 37.25 907.00 -Front-load HEPA 40.00 1520.00 -Front-load cartridge 40.00 1174.00 -Front-load short bag 45.00 980.00 Gas heat - 200 MBH n/a n/a - 300 MBH n/a n/a - 360 MBH n/a n/a - 560 MBH 64.00 1900.50 - 700 MBH 74.00 2241.90 - 860 MBH 74.00 2331.90 77.00 2082.90 - 1000 MBH - 1250-1750 MBH 106.00 2942.80 - 2000 MBH 114.00 3430.30 -Building Steam 14.00 897.00 -Atmospheric 19.00 803.00 Humidifier Mixing box -with angled filters 48.00 653.36 -with front/back Traq and top Traq dampers 68.50 1365.59 - reduced length mixing box with side/top/back/bottom airfoil damper 41.50 1022.70 n/a n/a -3 feet 38.00 1332.00 -5 feet 62.00 1945.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 1148.00 UV light 14.00 419.43 Multizone Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 76.00 1223.00 -with airfoil damper and one side Traq damper 76.00 1266.00 Exhaust damper section 22.40 586.60 - Back inlet hood - airfoil and Traq 125.38 270.00 - Side inlet hood - airfoil and Traq 37.25 174.00 - Exhaust hood - airfoil 37.25 114.00 - Economizer inlet hood 75.50 345.00 15 in. long - 24-in. depth 15.00 155.00 15 in. long - 36-in. depth 15.00 209.00 15 in. long - 48-in. depth 15.00 262.00 179.00 Hoods Pipe Cabinets CLCH-PRC022A-EN 24 in. long - 24-in. depth 24.00 24 in. long - 36-in. depth 24.00 236.00 24 in. long - 48-in. depth 24.00 292.00 133 General Data Table 110. Section dimensions (inches) and weights (pounds) - unit size 57 Pipe Cabinets Length (in.) Weight (lb.) 48 in. long - 24-in. depth 48.00 244.00 48 in. long - 36-in. depth 48.00 309.00 48 in. long - 48-in. depth 48.00 373.00 373.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 454.00 96 in. long - 48-in. depth 96.00 536.00 Table 111. Filter data for unit size 57 Filter Type Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media Angled (2-in. or 4-in.) Pleated, permanent, throwaway media Area ft² Qty–Size (in.) 63.33 12 - 20x25 3 - 20x20 4 - 16x25 1 - 16x20 100.00 36 - 20x20 Side load bag or cartridge 60.00 15 - 24x24 Front load bag or cartridge 60.00 15 - 24x24 Front load HEPA 3 1 3 1 3 1 57.00 - 24x30 24x24 24x30 24x24 24x30 24x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 112.Coil availability - size 57 Section Type Small 134 1/2-in Unit Coils 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils 2 rows 1-2 rows Medium 2–4 rows 1–3 rows Extended-medium 2–8 rows 1-6 rows Medium-large 2-8 rows 1-8 rows -with access 2-4 rows n/a Large horizontal 2–8 rows 1–8 rows -with access 2–8 rows 1–10 rows CLCH-PRC022A-EN General Data Table 113.Coil data for unit size 57 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 2, 4, 6, 8 Aluminum 56.89 2-36.25 x 113 1, 2, 3, 4, 6, 8 Aluminum or Copper 56.50 2-36 x 113 10 Aluminum 56.50 2-36 x 113 1 Aluminum or Copper 51.79 1-30 x 113 2-18 x 113 2, 4, 6, 8 Aluminum 43.16 1-55 x 113 1/2-inch unit coils -UA, UW, UF, UU (stacked) 5/8-inch unit coils -W, WD, 5A, 5W, D1, D2 (stacked) -W, WD, D1, D2 (stacked) 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL -FD (stacked) 4 to 6 Aluminum 44.14 1-31.25 x 113 1-25 x 113 1, 2, 3, 4, 6, 8 Aluminum or Copper 42.38 1-54 x 113 10 Aluminum 42.38 1-54 x 113 1 Aluminum or Copper 42.38 1-30 x 113 1-24 x 113 5/8-inch modified coils -W, WD, 5A, 5W, D1, D2 -W, WD, D1, D2 1-inch modified coil -NS (stacked) Multizone coils n/a n/a Table 114.Fan data for unit size 57 Housed Fans -Low Pressure Size/Type 32-in. FC 28-in. FC 25-in. FC 32-in. AF 28-in. AF 25-in. AF Fan name 32FA 28FA 25FA 32AA 28AA 25AA Max rpm 675 750 850 1300 1500 1650 ODP NEMA Premium motor hp range 7.5-30 7.5-25 7.5-20 7.5-30 7.5-20 7.5-20 Outlet area (ft²) 11.11 8.81 6.95 11.11 8.81 6.95 Bearing/Shaft size (in.) 2.19 1.94 1.69 2.19 1.94 1.69 Housed Fans - High Pressure Size/Type 32-in. FC 28-in. FC 25-in. FC 32-in. AF 28-in. AF 25-in. AF Fan name 32FB 28FB 25FB 32AB 28AB 25AB Max rpm 760 860 1025 1700 2050 2200 ODP NEMA Premium motor hp range 7.5-60 7.5-40 7.5-40 7.5-60 7.5-60 7.5-50 Outlet area (ft²) 11.11 8.81 6.95 11.11 8.81 6.95 Bearing/Shaft size (in.) 2.19 2.44 2.44 2.19 2.19 2.00 Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 2-30-in AF 2-30-in AF Reduced Width Nominal Width Size/Type 44-in. AF 40-in. AF 44-in. AF 40-in. AF Fan name 44PA 40PA 44PB 40PB 30NR 30NF Max rpm 1100 1150 1200 1400 1851 1851 ODP NEMA Premium motor hp range 7.5-60 7.5-30 7.5-75 7.5-75 10-30 10-30 Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 2.19 2.44 2.44 2.19 n/a n/a CLCH-PRC022A-EN 135 General Data Unit Size 58 Table 115. Section dimensions (inches) and weights (pounds) - unit size 58 Nominal airflow 29,000 Airflow at 625 fpm 38,194 Height - indoor unit (in.) 116.25 Width (in.) Height - outdoor unit (in.) includes base drip lip 93.50 Available for indoor use only n/a n/a Length (in.) Weight (lb.) -Small horizontal 10.00 255.92 -Medium horizontal 14.00 292.80 -Extended-medium horizontal 19.00 338.89 Weight add for outdoor unit (lbs./in. of unit length) Section type Access or blank -Medium-large horizontal 29.50 389.59 -Large horizontal or turning 46.00 661.42 -Extra-large horizontal or turning n/a n/a -Ducted inlet or ducted outlet section 10.00 255.90 Blender 48.00 718.81 n/a n/a -Small horizontal (with 4-row UW) 10.00 1014.74 -Medium horizontal (with 8-row UW) 14.00 1686.19 -Extended-medium horizontal (with 8-row UW) 19.00 1738.19 Cool Dry Quiet (CDQ) Desiccant Dehumidification Section Coils -Medium-large horizontal (with 10-row W) 29.50 3116.00 -Large horizontal or vertical (with 10-row W) 46.00 3287.59 n/a n/a 29.50 1817.25 -Electric Heat Coil -Integral-face-and-bypass (IFB) coil --Less than 4 rows --4 rows n/a n/a Controls section (includes largest available VFD) 28.50 790.00 Diffuser 24.50 387.24 Discharge plenum -Horizontal 46.00 798.32 -Vertical n/a n/a Energy Wheel n/a n/a Face-and-Bypass Dampers -Face-and-bypass 19.00 336.54 -External face-and-bypass 27.75 417.20 -Internal face-and-bypass or face damper only 19.00 336.54 Fan -Belt-drive plenum (BDP) fan with motor n/a n/a -Housed fan FC with motor 88.00 3414.05 -Housed AF/BC fans with motor 88.00 3483.58 -Direct-drive plenum fan with motor 88.00 4349.06 -Side load 2-in. angled 24.50 777.14 -Side load 4-in. angled 24.50 778.73 -Side load cartridge 12-in. or short bag 18-in. 24.50 980.36 Filters 136 CLCH-PRC022A-EN General Data Table 115. Section dimensions (inches) and weights (pounds) - unit size 58 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 14.00 426.12 -Side load 4-in. flat 14.00 476.21 -Side load 2-in. and 4-in. combination flat 19.00 667.97 -Long bag 30-in. 37.25 945.00 -Front-load HEPA 40.00 1561.00 -Front-load cartridge 40.00 1169.00 -Front-load short bag 45.00 1049.00 n/a n/a -Building Steam 14.00 807.00 -Atmospheric 19.00 742.00 46.00 675.14 n/a n/a Gas heat Humidifier Mixing box -with angled filters -with front/back Traq and top Traq dampers - reduced length mixing box with side/top/back/bottom airfoil damper n/a n/a Multizone n/a n/a -3 feet 38.00 1312.00 -5 feet 62.00 2030.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 1132.00 n/a n/a Silencer UV light Table 116.Filter data for unit size 58 Filter Type Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media Angled (2-in. or 4-in.) Pleated, permanent, throwaway media Area ft² Qty–Size (in.) 63.33 12 - 20x25 3 - 20x20 4 - 16x25 1 - 16x20 100.00 36 - 20x20 Side load bag or cartridge 60.00 15 - 24x24 Front load bag or cartridge 60.00 15 - 24x24 Front load HEPA 57.00 3 1 3 1 3 1 - 24x30 24x24 24x30 24x24 24x30 24x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 117. Coil availability - size 58 Section Type Small Medium Extended-medium 2 rows 2–6 rows (4 row cooling) 2–8 rows 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils 1-2 rows 1–4 rows without IDP 1-3 rows with IDP 1-8 rows without IDP 1-6 rows with IDP Medium-large 2-8 rows -with access 2-8 rows 1-6 rows Large horizontal 2–8 rows 1–10 rows -with access 2–8 rows 1–10 rows n/a n/a Large vertical CLCH-PRC022A-EN 1/2-in Unit Coils 1-10 rows 137 General Data Table 118. Coil data for unit size 58 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 2, 4, 6, 8 Aluminum 56.89 1-57.50 x80 1-43.75 x 80 1, 2, 3, 4, 6, 8, 10 Aluminum or Copper 56.67 2-51 x 80 6, 8, 10 Aluminum 56.67 2-51 x 80 1 Aluminum or Copper 53.33 2-33 x 80 1-30 x 80 2, 4, 6, 8 Aluminum 43.75 1-42.50 x 80 1-36.25 x 80 1, 2, 3, 4, 6, 8 Aluminum or Copper 42.33 10 Aluminum 43.33 1 Aluminum or Copper 43.33 1/2-inch unit coils -UA, UW, UF, UU (stacked) 5/8-inch unit coils -W, WD, 5A, 5W, D1, D2 (stacked) -W, WD, 5D 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL, FD (stacked) 5/8-inch modified coils W, WD, 5A, 5W, D1, D2 (stacked) -W, WD, D1, D2 (stacked) 1-42 1-36 1-42 1-36 x x x x 80 80 80 80 1-inch modified coil -NS (stacked) Multizone coils n/a 1-30 x 80 2-24 x 80 n/a Table 119. Fan data for unit size 58 Housed Fans - Low Pressure Size/Type 32-in. FC 28-in. FC 25-in. FC 32-in. AF 28-in. AF 25-in. AF Fan name 32FA 28FA 25FA 32AA 28AA 25AA Max rpm 675 750 850 1300 1500 1650 ODP NEMA Premium motor hp range 7.5-30 7.5-25 7.5-20 7.5-30 7.5-20 7.5-20 Outlet area (ft²) 11.11 8.81 6.95 11.11 8.81 6.95 Bearing/Shaft size (in.) 2.19 1.94 1.69 2.19 1.94 1.69 Size/Type 32-in. FC 28-in. FC 25-in. FC 32-in. AF 28-in. AF 25-in. AF Fan name 32FB 28FB 25FB 32AB 28AB 25AB Max rpm 760 860 1025 1700 2050 2200 ODP NEMA Premium motor hp range 7.5-60 7.5-40 7.5-40 7.5-60 7.5-60 7.5-50 Outlet area (ft²) 11.11 8.81 6.95 11.11 8.81 6.95 Bearing/Shaft size (in.) 2.19 2.44 2.44 2.19 2.19 2.00 Housed Fans - High Pressure Belt-drive Plenum Fans Low Pressure Size/Type n/a n/a Direct-Drive Plenum Fans High Pressure n/a n/a High Pressure 4- 22-in AF 4-22-in AF Reduced Width Nominal Width Fan name 22SR 22SF Max rpm 2675 2675 ODP NEMA Premium motor hp range 3-20 3-20 Outlet area (ft²) n/a n/a Bearing/Shaft size (in.) n/a n/a 138 CLCH-PRC022A-EN General Data Unit Size 66 Table 120. Section dimensions (inches) and weights (pounds) - unit size 66 Nominal airflow 33,000 Airflow at 625 fpm 47,225 Height - indoor unit (in.) Width (in.) Height - outdoor unit (in.) includes base drip lip Weight add for outdoor unit (lbs./in. of unit length) Section type 92.50 140.50 97.63 2.57 Length (in.) Weight (lb.) -Small horizontal 10.00 289.35 -Medium horizontal 15.00 430.36 -Extended-medium horizontal 19.00 476.36 Access or blank -Medium-large horizontal 24.50 574.11 -Large horizontal or turning 49.00 907.93 -Extra-large horizontal or turning n/a n/a -Ducted inlet or ducted outlet section 10.00 372.90 Blender 49.00 970.30 n/a n/a Cool Dry Quiet (CDQ) Desiccant Dehumidification Section Coils -Small horizontal (with 4-row UW) n/a n/a -Medium horizontal (with 8-row UW) 15.00 2220.94 -Extended-medium horizontal (with 8-row UW) 19.00 2275.46 -Medium-large horizontal (with 10-row W) 24.50 3876.05 -Large horizontal or vertical (with 10-row W) n/a n/a -Electric Heat Coil 49.00 2857.00 -Integral-face-and-bypass (IFB) coil --Less than 4 rows 29.50 2322.61 --4 rows n/a n/a Controls section (includes largest available VFD) 28.50 964.00 Diffuser 27.50 571.76 Discharge plenum -Horizontal 49.00 1058.35 -Vertical n/a n/a Energy Wheel n/a n/a Face-and-Bypass Dampers -Face-and-bypass 19.00 888.33 -External face-and-bypass 39.00 1256.07 -Internal face-and-bypass or face damper only 19.00 888.33 -Belt-drive plenum (BDP) fan with motor 61.00 4062.62 -Housed fan FC with motor 84.00 4201.67 -Housed AF/BC fans with motor 84.00 4311.38 -Direct-drive plenum fan with motor 84.00 4903.24 -Side load 2-in. angled 27.50 989.00 -Side load 4-in. angled 27.50 999.89 -Side load cartridge 12-in. or short bag 18-in. 27.50 1239.99 Fan Filters CLCH-PRC022A-EN 139 General Data Table 120. Section dimensions (inches) and weights (pounds) - unit size 66 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 15.00 598.12 -Side load 4-in. flat 15.00 657.87 -Side load 2-in. and 4-in. combination flat 19.00 853.08 -Long bag 30-in. 37.25 1095.00 -Front-load HEPA 40.00 1846.00 -Front-load cartridge 40.00 1449.00 -Front-load short bag 45.00 1231.000 Gas heat - 200 MBH n/a n/a - 300 MBH n/a n/a - 360 MBH n/a n/a - 560 MBH n/a n/a - 700 MBH 74.00 2490.60 - 860 MBH 74.00 2580.60 74.00 2300.60 - 1000 MBH - 1250-1750 MBH 109.00 3309.40 - 2000 MBH 112.00 3688.30 - 2400 MBH 118.00 3890.30 -Building Steam 15.00 1123.00 -Atmospheric 19.00 977.00 Humidifier Mixing box -with angled filters 49.00 946.02 -with front/back Traq and top Traq dampers 84.00 1907.28 - reduced length mixing box with side/top/back/bottom airfoil damper 41.50 1328.50 n/a n/a -3 feet 38.00 1573.00 -5 feet 62.00 2313.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 1362.00 UV light 15.00 574.52 Multizone Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 83.00 1680.00 -with airfoil damper and one side Traq damper 83.00 1722.00 Exhaust damper section 22.40 755.30 - Back inlet hood - airfoil and Traq 126.00 317.00 - Side inlet hood - airfoil and Traq 37.25 189.00 - Exhaust hood - airfoil 37.25 129.00 - Economizer inlet hood 83.00 418.00 15 in. long - 24-in. depth 15.00 160.00 15 in. long - 36-in. depth 15.00 215.00 15 in. long - 48-in. depth 15.00 270.00 Hoods Pipe Cabinets 140 CLCH-PRC022A-EN General Data Table 120. Section dimensions (inches) and weights (pounds) - unit size 66 Pipe Cabinets Length (in.) Weight (lb.) 24 in. long - 24-in. depth 24.00 185.00 24 in. long - 36-in. depth 24.00 243.00 24 in. long - 48-in. depth 24.00 301.00 251.00 48 in. long - 24-in. depth 48.00 48 in. long - 36-in. depth 48.00 317.00 48 in. long - 48-in. depth 48.00 384.00 383.00 96 in. long - 24-in. depth 96.00 96 in. long - 36-in. depth 96.00 466.00 96 in. long - 48-in. depth 96.00 549.00 Table 121.Filter data for unit size 66 Filter Type Area ft² Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media Angled (2-in. or 4-in.) Pleated, permanent, throwaway media Qty–Size (in.) 20 - 20x24 4 - 20x16 36 - 20x20 6 - 16x20 75.56 113.33 Side load bag or cartridge 66.67 Front load bag or cartridge 66.00 Front load HEPA 66.00 20 - 20x24 3 - 12x24 15 - 24x24 4 - 24x30 1 - 24x12 4 - 24x30 1 - 24x12 4 - 24x30 1 - 24x12 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 122.Coil availability - size 66 Section Type Small CLCH-PRC022A-EN 1/2-in Unit Coils 5/8-in Unit Coils 1/2-in and 5/8-in Modified Coils n/a n/a Medium 2–4 rows 1–3 rows Extended-medium 2–8 rows 1-6 rows Medium-large 2-8 rows 1-10 rows -with access n/a n/a Large horizontal n/a n/a -with access n/a n/a Large vertical n/a n/a -with access n/a n/a 141 General Data Table 123.Coil data for unit size 66 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 2, 4, 6, 8 Aluminum 65.63 2-37.50 x 126 -W, WD, D1, D (stacked0 4, 6, 8 Aluminum or Copper 65.63 2-37.50 x 126 -W, WD, D1, D2 (stacked) 10 Aluminum 65.63 2-37.50 x 126 -W, 5A, 5W, D1 (stacked) 1, 2, 3 Aluminum or Copper 65.63 1-42 x 126 1-33 x 126 1 Aluminum or Copper 60.38 1-33 x 126 2-18 x 126 2, 4, 6, 8 Aluminum 51.41 1-33.75 x 126 1-25 x 126 1, 2, 3, 4, 6, 8 Aluminum or Copper 49.88 10 Aluminum 49.88 1 Aluminum or Copper 49.88 1/2-inch unit coils -UA, UW, UF, UU (stacked) 5/8-inch unit coils 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL, FD (stacked) 5/8-inch modified coils -W, WD, 5A, 5W, D1, D2 (stacked) W, WD, D1, D2 (stacked) 1-33 1-24 1-33 1-24 x x x x 126 126 126 126 1-inch modified coil -NS (stacked) Multizone coils 1-33 x 126 1-24 x 126 n/a n/a Table 124.Fan data for unit size 66 Housed Fans - Low Pressure Size/Type 36-in. FC 32-in. FC 28-in. FC 36-in. AF 32-in. AF 28-in. AF Fan name 36FA 32FA 28FA 36AA 32AA 28AA Max rpm 600 675 750 1250 1300 1500 ODP NEMA Premium motor hp range 10-40 10-30 10-25 10-30 10-30 10-20 Outlet area (ft²) 13.91 11.11 8.81 13.91 11.11 8.81 Bearing/Shaft size (in.) 2.44 2.19 1.94 2.44 2.19 1.94 Housed Fans - High Pressure Size/Type 36-in. FC 32-in. FC 28-in. FC 36-in. AF 32-in. AF 28-in. AF Fan name 36FB 32FB 28FB 36AB 32AB 28AB Max rpm 665 760 860 1550 1700 2050 ODP NEMA Premium motor hp range 10-60 10-60 10-40 10-75 10-60 10-60 Outlet area (ft²) 13.91 11.11 8.81 13.91 11.11 8.81 Bearing/Shaft size (in.) 2.44 2.19 2.44 2.44 2.19 2.19 Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 4-22-in AF 4-22-in AF Nominal Width Extended Width Size/Type 44-in. AF 40-in. AF 44-in. AF 40-in. AF Fan name 44PA 40PA 44PB 40PB 22SF Max rpm 1100 1150 1200 1400 2613 2613 ODP NEMA Premium motor hp range 10-60 10-30 10-75 10-75 5-25 7.5-25 142 22SW Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 2.19 2.44 2.44 2.19 n/a n/a CLCH-PRC022A-EN General Data Unit Size 80 Table 125. Section dimensions (inches) and weights (pounds) - unit size 80 Nominal airflow 40,000 Airflow at 625 fpm 53,475 Height - indoor unit (in.) 107.50 Width (in.) 140.50 Height - outdoor unit (in.) includes base drip lip 112.63 Weight add for outdoor unit (lbs./in. of unit length) Section type 2.57 Length (in.) Weight (lb.) -Small horizontal 10.00 305.74 -Medium horizontal 15.00 449.60 -Extended-medium horizontal 19.00 497.88 Access or blank -Medium-large horizontal 24.50 600.46 -Large horizontal or turning 54.00 1036.33 -Extra-large horizontal or turning n/a n/a -Ducted inlet or ducted outlet section 10.00 389.30 Blender 54.00 1112.23 n/a n/a Cool Dry Quiet (CDQ) Desiccant Dehumidification Section Coils -Small horizontal (with 4-row UW) n/a n/a -Medium horizontal (with 8-row UW) 15.00 2558.94 -Extended-medium horizontal (with 8-row UW) 19.00 2615.73 -Medium-large horizontal (with 10-row W) 24.50 4488.82 -Large horizontal or vertical (with 10-row W) n/a n/a -Electric Heat Coil n/a n/a 29.50 2378.60 -Integral-face-and-bypass (IFB) coil --Less than 4 rows --4 rows n/a n/a Controls section (includes largest available VFD) 28.50 1031.00 Diffuser 37.25 715.78 Discharge plenum -Horizontal 54.00 1198.64 -Vertical n/a n/a Energy Wheel n/a n/a Face-and-Bypass Dampers -Face-and-bypass 19.00 973.60 -External face-and-bypass 39.00 1348.84 -Internal face-and-bypass or face damper only 19.00 954.26 -Belt-drive plenum (BDP) fan with motor 63.00 4745.62 -Housed fan FC with motor 92.00 4922.58 -Housed AF/BC fans with motor 92.00 5101.29 -Direct-drive plenum fan with motor 92.00 5456.86 -Side load 2-in. angled 27.50 1088.02 -Side load 4-in. angled 27.50 1105.14 -Side load cartridge 12-in. or short bag 18-in. 27.50 1364.91 Fan Filters CLCH-PRC022A-EN 143 General Data Table 125. Section dimensions (inches) and weights (pounds) - unit size 80 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 15.00 637.02 -Side load 4-in. flat 15.00 729.15 -Side load 2-in. and 4-in. combination flat 19.00 981.02 -Long bag 30-in. 37.25 1271.00 -Front-load HEPA 40.00 2141.00 -Front-load cartridge 40.00 1671.00 -Front-load short bag 45.00 1365.00 n/a n/a -Building Steam 15.00 1215.00 -Atmospheric 19.00 1078.00 -with angled filters 54.00 1077.83 -with front/back Traq and top Traq dampers 92.00 2151.42 - reduced length mixing box with side/top/back/bottom airfoil damper 41.50 1453.60 n/a n/a -3 feet 38.00 1741.00 -5 feet 62.00 2555.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 1451.00 UV light 15.00 604.11 Gas heat Humidifier Mixing box Multizone Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 86.00 1851.00 -with airfoil damper and one side Traq damper 86.00 1920.00 Exhaust damper section 22.40 820.10 140.00 344.00 Hoods - Back inlet hood - airfoil and Traq - Side inlet hood - airfoil and Traq 37.25 258.00 - Exhaust hood - airfoil 37.25 174.00 - Economizer inlet hood 86.00 522.00 15 in. long - 24-in. depth 15.00 181.00 15 in. long - 36-in. depth 15.00 243.00 15 in. long - 48-in. depth 15.00 304.00 Pipe Cabinets 144 24 in. long - 24-in. depth 24.00 208.00 24 in. long - 36-in. depth 24.00 273.00 24 in. long - 48-in. depth 24.00 338.00 48 in. long - 24-in. depth 48.00 281.00 48 in. long - 36-in. depth 48.00 354.00 48 in. long - 48-in. depth 48.00 427.00 96 in. long - 24-in. depth 96.00 427.00 96 in. long - 36-in. depth 96.00 517.00 96 in. long - 48-in. depth 96.00 606.00 CLCH-PRC022A-EN General Data Table 126.Filter data for unit size 80 Filter Type Area ft² Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media Qty–Size (in.) 20 - 20x24 4 - 20x16 5 - 12x24 48 - 20x20 8 - 16x20 20 - 24x24 4 - 24x12 1 - 12x24 19 - 24x24 4 - 24x12 4 - 24x30 1 - 24x12 4 - 24x30 1 - 24x12 4 - 24x30 1 - 24x12 5 - 12x24 85.56 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 151.11 Side load bag or cartridge 88.00 Front load bag or cartridge 86.00 Front load HEPA 76.00 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 127. Coil availability - size 80 Section Type 1/2-in Unit Coils Small 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils n/a n/a Medium 2–4 rows 1–3 rows Extended-medium 2–8 rows 1-6 rows Medium-large 2-8 rows 1-10 rows -with access n/a n/a Large horizontal n/a n/a -with access n/a n/a Large vertical n/a n/a -with access n/a n/a Table 128.Coil data for unit size 80 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 2, 4, 6, 8 Aluminum 78.75 2-45 x 126 1, 2, 3, 4, 6, 8 Aluminum or Copper 78.75 2-45 x 126 10 Aluminum 78.75 2-45 x 126 1 Aluminum or Copper 73.50 2-30 x 126 1-24 x 126 2, 4, 6, 8 Aluminum 63.44 2-36.25 x 126 1, 2, 3, 4, 6, 8 Aluminum or Copper 63.00 2-36 x 126 10 Aluminum 63.00 2-36 x 126 1 Aluminum or Copper 60.38 2-18 x 126 1-33 x 126 1/2-inch unit coils -UA, UW, UF, UU (stacked) 5/8-inch unit coils -W, WD, 5D, 5A, 5W, D1, D2 (stacked) -W, WD, 5D, D1, D2 (stacked) 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL, FD (stacked) 5/8-inch modified coils -W, WD, 5A 5W, D1, D2 -W, WD, D1, D2 1-inch modified coil -NS (stacked) Multizone coils CLCH-PRC022A-EN n/a n/a 145 General Data Table 129.Fan data for unit size 80 Housed Fans - Low Pressure Size/Type 36-in. FC 32-in. FC 28-in. FC 36-in. AF 32-in. AF 28-in. AF Fan name 36FA 32FA 28FA 36AA 32AA 28AA 600 675 750 1250 1300 1500 ODP NEMA Premium motor hp range 10-40 10-30 10-25 10-30 10-30 10-20 Outlet area (ft²) 13.91 11.11 8.81 13.91 11.11 8.81 2.4375 2.1875 1.9375 2.4375 2.1875 1.9375 Size/Type 36-in. FC 32-in. FC 28-in. FC 36-in. AF 32-in. AF 28-in. AF Fan name 36FB 32FB 28FB 36AB 32AB 28AB 665 760 860 1550 1700 2050 ODP NEMA Premium motor hp range 10-60 10-60 10-40 10-75 10-60 10-60 Outlet area (ft²) 13.91 11.11 8.81 13.91 11.11 8.81 2.4375 2.1875 2.4375 2.4375 2.1875 2.1875 Max rpm Bearing/Shaft size (in.) Housed Fans - High Pressure Max rpm Bearing/Shaft size (in.) Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure (4) 22-in. AF (4) 22-in. AF Nominal Width Extended Width Size/Type 44-in. AF 40-in. AF 44-in. AF 40-in. AF Fan name 44PA 40PA 44PB 40PB 22SF Max rpm 1100 1150 1200 1400 2613 2613 ODP NEMA Premium motor hp range 10-60 10-30 10-75 10-75 5-25 7.5-25 Outlet area (ft²) Bearing/Shaft size (in.) 146 22SW n/a n/a n/a n/a n/a n/a 2.1875 2.4375 2.4375 2.1875 n/a n/a CLCH-PRC022A-EN General Data Unit Size 100 Table 130. Section dimensions (inches) and weights (pounds) - unit size 100 Nominal airflow 50,000 Airflow at 625 fpm 65,106 Height - indoor unit (in.) 119.75 Width (in.) 154.50 Height - outdoor unit (in.) includes base drip lip 124.88 Weight add for outdoor unit (lbs./in. of unit length) Section type 2.80 Length (in.) Weight (lb.) -Small horizontal 10.00 337.96 -Medium horizontal 15.00 493.59 -Extended-medium horizontal 19.00 545.85 Access or blank -Medium-large horizontal 24.50 656.89 -Large horizontal or turning 60.00 1242.40 -Extra-large horizontal or turning n/a n/a -Ducted inlet or ducted outlet section 10.00 428.30 Blender 60.00 1345.03 n/a n/a Cool Dry Quiet (CDQ) Desiccant Dehumidification Section Coils -Small horizontal (with 4-row UW) n/a n/a -Medium horizontal (with 8-row UW) 15.00 3094.04 -Extended-medium horizontal (with 8-row UW) 19.00 3163.21 -Medium-large horizontal (with 10-row W) 24.50 5499.42 -Large horizontal or vertical (with 10-row W) n/a n/a -Electric Heat Coil n/a n/a 29.50 2865.77 -Integral-face-and-bypass (IFB) coil --Less than 4 rows --4 rows n/a n/a Controls section (includes largest available VFD) 28.50 1146.00 Diffuser 37.25 781.92 Discharge plenum -Horizontal 60.00 1423.88 -Vertical n/a n/a Energy Wheel n/a n/a Face-and-Bypass Dampers -Face-and-bypass 19.00 1093.88 -External face-and-bypass 39.00 1498.11 -Internal face-and-bypass or face damper only 19.00 1082.84 -Belt-drive plenum (BDP) fan with motor 73.75 6223.51 -Housed fan FC with motor 96.00 5297.62 -Housed AF/BC fans with motor 96.00 6025.44 -Direct-drive plenum fan with motor 96.00 7176.65 -Side load 2-in. angled 27.50 1157.16 -Side load 4-in. angled 27.50 1201.91 -Side load cartridge 12-in. or short bag 18-in. 27.50 1746.31 Fan Filters CLCH-PRC022A-EN 147 General Data Table 130. Section dimensions (inches) and weights (pounds) - unit size 100 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 15.00 716.56 -Side load 4-in. flat 15.00 803.46 -Side load 2-in. and 4-in. combination flat 19.00 1078.09 -Long bag 30-in. 37.25 1393.00 -Front-load HEPA 40.00 2554.00 -Front-load cartridge 40.00 1923.00 -Front-load short bag 45.00 1539.00 Gas heat - 860 MBH - 1000 MBH - 1250-1750 MBH n/a n/a 84.00 3156.00 92.00 3878.50 - 2000 MBH 109.00 4503.50 - 2400 MBH 121.00 4715.90 -Building Steam 15.00 1363.00 -Atmospheric 19.00 1265.00 -with angled filters 60.00 1287.99 -with front/back Traq and top Traq dampers 96.00 2473.12 - reduced length mixing box with side/top/back/bottom airfoil damper 47.00 1731.30 n/a n/a -3 feet 38.00 2196.00 -5 feet 62.00 3230.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 1707.00 UV light 15.00 667.60 Humidifier Mixing box Multizone Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 93.00 2173.00 -with airfoil damper and one side Traq damper 93.00 2290.00 Exhaust damper section 22.40 935.50 - Back inlet hood - airfoil and Traq 140.00 491.00 - Side inlet hood - airfoil and Traq 43.00 412.00 - Exhaust hood - airfoil 43.00 206.00 - Economizer inlet hood 93.00 629.00 15 in. long - 24-in. depth 15.00 198.00 15 in. long - 36-in. depth 15.00 265.00 15 in. long - 48-in. depth 15.00 333.00 24 in. long - 24-in. depth 24.00 227.00 24 in. long - 36-in. depth 24.00 298.00 24 in. long - 48-in. depth 24.00 368.00 Hoods Pipe Cabinets 148 48 in. long - 24-in. depth 48.00 306.00 48 in. long - 36-in. depth 48.00 385.00 48 in. long - 48-in. depth 48.00 463.00 CLCH-PRC022A-EN General Data Table 130. Section dimensions (inches) and weights (pounds) - unit size 100 Pipe Cabinets Length (in.) Weight (lb.) 96 in. long - 24-in. depth 96.00 462.00 96 in. long - 36-in. depth 96.00 558.00 96 in. long - 48-in. depth 96.00 653.00 Table 131.Filter data for unit size 100 Filter Type Area ft² Qty–Size (in.) Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 104.17 30 - 20x25 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 166.67 48 - 20x25 Side load bag or cartridge 113.33 Front load bag or cartridge 108.00 Front load HEPA 102.00 28 - 24x20 4 - 24x12 6 - 12x24 6 - 12x24 24 - 24x24 6 - 30x24 6 - 30x24 6 - 30x24 6 - 12x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 132.Coil availability - size 100 Section Type 1/2-in Unit Coils Small 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils n/a n/a Medium 2–4 rows 1–3 rows Extended-medium 2–8 rows 1-6 rows Medium-large 2-8 rows 1-10 rows -with access n/a n/a Large horizontal n/a n/a -with access n/a n/a Large vertical n/a n/a -with access n/a n/a Table 133.Coil data for unit size 100 Coil Type Rows Fin Type 2, 4, 6, 8 Aluminum 1, 2, 3, 4, 6, 8 10 Area ft² Qty–Size (in.) 1/2-inch unit coils -UA, UW, UF, UU (stacked) 99.14 1-57.50 x 141 1-43.75 x 141 Aluminum or Copper 99.88 2-51 x 141 Aluminum 99.88 2-51 x 141 1 Aluminum or Copper 94.00 2-33 x 141 1-30 x 141 2, 4, 6, 8 Aluminum 77.11 1-42.50 x 141 1-36.25 x 141 5/8-inch unit coils -W, WD, 5D, 5A 5W, D1, D2 (stacked) W, WD, 5D, D1, D2 (stacked) 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL, FD (stacked) CLCH-PRC022A-EN 149 General Data Table 133.Coil data for unit size 100 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 1, 2, 3, 4, 6, 8 Aluminum or Copper 76.38 10 Aluminum 76.38 1 Aluminum or Copper 76.38 5/8-inch modified coils -W, WD, 5A 5W, D1, D2 (stacked) W, WD, D1, D2 (stacked) 1-42 1-36 1-42 1-36 x x x x 141 141 141 141 1-inch modified coil -NS Multizone coils n/a 1-30 x 141 2-24 x 141 n/a Table 134.Fan data for unit size 100 Housed Fans - Low Pressure Size/Type 40-in. FC 36-in. FC 32-in. FC 44-in. AF 40-in. AF 36-in. AF 32-in. AF Fan name 40FA 36FA 32FA 44AA 40AA 36AA 32AA Max rpm 550 600 675 850 1200 1250 1300 ODP NEMA Premium motor hp range 15-40 15-40 15-30 15-40 15-60 15-30 15-30 Outlet area (ft²) 17.45 13.91 11.11 21.88 17.45 13.91 11.11 Bearing/Shaft size (in.) 2.44 2.44 2.19 2.94 2.19 2.44 2.19 Housed Fans - High Pressure Size/Type 40-in. FC 36-in. FC 32-in. FC 44-in. AF 40-in. AF 36-in. AF 32-in. AF Fan name 40FB 36FB 32FB 44AB 40AB 36AB 32AB Max rpm 600 665 760 1150 1350 1550 1700 ODP NEMA Premium motor hp range 15-75 15-75 15-60 15-100 15-100 15-75 15-60 Outlet area (ft²) 17.45 13.91 11.11 21.88 17.45 13.91 11.11 Bearing/Shaft size (in.) 2.44 2.44 2.19 2.94 2.44 2.44 2.19 Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 6-24.5-in AF 6 -24.5-in AF 49-in. AF Nominal Width Extended Width Size/Type 55-in. AF 49-in. AF 55-in. AF Fan name 55PA 49PA 55PB 49PB 24SF 24SW Max rpm 850 950 975 1100 2344 2344 ODP NEMA Premium motor hp range 15-75 15-60 15-125 15-100 5-20 5-20 Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 2.44 2.19 2.94 2.44 n/a n/a 150 CLCH-PRC022A-EN General Data Unit Size 120 Table 135. Section dimensions (inches) and weights (pounds) - unit size 120 Nominal airflow 60,000 Airflow at 625 fpm 76,388 Height - indoor unit (in.) 119.75 Width (in.) 182.00 Height - outdoor unit (in.) includes base drip lip 124.88 Weight add for outdoor unit (lbs./in. of unit length) Section type 3.24 Length (in.) Weight (lb.) -Small horizontal 10.00 374.94 -Medium horizontal 15.00 549.13 -Extended-medium horizontal 19.00 605.56 Access or blank -Medium-large horizontal 24.50 725.47 -Large horizontal or turning 60.00 1387.96 -Extra-large horizontal or turning n/a n/a -Ducted inlet or ducted outlet section 10.00 478.60 Blender 60.00 1567.62 n/a n/a Cool Dry Quiet (CDQ) Desiccant Dehumidification Section Coils -Small horizontal (with 4-row UW) n/a n/a -Medium horizontal (with 8-row UW) 15.00 3638.44 -Extended-medium horizontal (with 8-row UW) 19.00 3712.02 -Medium-large horizontal (with 10-row W) 24.50 6713.50 -Large horizontal or vertical (with 10-row W) n/a n/a -Electric Heat Coil n/a n/a 29.50 2936.42 -Integral-face-and-bypass (IFB) coil -Less than 4 rows --4 rows n/a n/a Controls section (includes largest available VFD) 28.50 1266.00 Diffuser 37.25 860.66 Discharge plenum -Horizontal 60.00 1585.80 -Vertical n/a n/a Energy Wheel n/a n/a Face-and-Bypass Dampers -Face-and-bypass 19.00 1205.53 -External face-and-bypass 39.00 1643.69 -Internal face-and-bypass or face damper only 19.00 1194.50 -Belt-drive plenum (BDP) fan with motor 82.25 7341.11 -Housed fan FC with motor 96.00 5600.08 -Housed AF/BC fans with motor 96.00 6891.90 -Direct-drive plenum fan with motor 96.00 7382.51 -Side load 2-in. angled 27.50 1282.20 -Side load 4-in. angled 27.50 1338.65 -Side load cartridge 12-in. or short bag 18-in. 27.50 1903.54 Fan Filters CLCH-PRC022A-EN 151 General Data Table 135. Section dimensions (inches) and weights (pounds) - unit size 120 Filters Length (in.) Weight (lb.) -Side load 2-in. flat 15.00 817.63 -Side load 4-in. flat 15.00 913.90 -Side load 2-in. and 4-in. combination flat 19.00 1165.92 -Long bag 30-in. 37.25 1550.00 -Front-load HEPA 40.00 2925.00 -Front-load cartridge 40.00 2156.00 -Front-load short bag 45.00 1696.00 Gas heat - 860 MBH - 1000 MBH n/a n/a 92.00 3125.30 3886.60 - 1250-1750 MBH 102.00 - 2000 MBH 109.00 4391.20 - 2400 MBH 119.00 4668.50 -Building Steam 15.00 1551.00 -Atmospheric 19.00 1492.00 -with angled filters 60.00 1433.55 -with front/back Traq and top Traq dampers 96.00 2790.48 - reduced length mixing box with side/top/back/bottom airfoil damper 53.00 2025.40 n/a n/a -3 feet 38.00 2555.00 -5 feet 62.00 3786.00 Trane Catalytic Air Cleaning System (TCACS) 36.00 1881.00 UV light 15.00 758.72 Humidifier Mixing box Multizone Silencer SECTIONS BELOW ARE FOR OUTDOOR UNITS ONLY Diagonal economizer -with airfoil dampers 93.00 2396.00 -with airfoil damper and one side Traq damper 93.00 2494.00 Exhaust damper section 22.40 1058.30 - Back inlet hood - airfoil and Traq 167.25 566.00 - Side inlet hood - airfoil and Traq 48.75 415.00 - Exhaust hood - airfoil 48.75 221.00 - Economizer inlet hood 93.00 778.00 15 in. long - 24-in. depth 15.00 198.00 15 in. long - 36-in. depth 15.00 265.00 15 in. long - 48-in. depth 15.00 333.00 24 in. long - 24-in. depth 24.00 227.00 24 in. long - 36-in. depth 24.00 298.00 24 in. long - 48-in. depth 24.00 368.00 Hoods Pipe Cabinets 152 48 in. long - 24-in. depth 48.00 306.00 48 in. long - 36-in. depth 48.00 385.00 48 in. long - 48-in. depth 48.00 463.00 CLCH-PRC022A-EN General Data Table 135. Section dimensions (inches) and weights (pounds) - unit size 120 Pipe Cabinets Length (in.) Weight (lb.) 96 in. long - 24-in. depth 96.00 462.00 96 in. long - 36-in. depth 96.00 558.00 96 in. long - 48-in. depth 96.00 653.00 Table 136.Filter data for unit size 120 Filter Type Area ft² Qty–Size (in.) Flat (2-in., 4-in., and 2-in/4-in high efficiency) pleated, permanent, throwaway media 122.22 32 - 25x20 4 - 25x16 Angled (2-in. or 4-in.) Pleated, permanent, throwaway media 194.44 56 - 25x20 Side load bag or cartridge 134.00 Front load bag or cartridge 126.00 Front load HEPA 119.00 28 - 24x24 4 - 24x12 7 - 12x24 7 - 12x24 28 - 24x24 7 - 30x24 7 - 30x24 7 - 30x24 7 - 12x24 Note: 2-inch filters available in permanent, throwaway, or pleated media; 4-inch filters available in pleated media, 65%, 85%, or 95% efficiency; Bag or cartridge filters available in 65%, 85%, or 95% efficiency. Table 137. Coil availability - size 120 Section Type 1/2-in Unit Coils Small 5/8-in Unit Coils, 1/2-in and 5/8-in Modified Coils n/a n/a Medium 2–4 rows 1–3 rows Extended-medium 2–8 rows 1-6 rows Medium-large 2-8 rows 1-10 rows -with access n/a n/a Large horizontal n/a n/a -with access n/a n/a Large vertical n/a n/a -with access n/a n/a Table 138.Coil data for unit size 120 Coil Type Rows Fin Type Area ft² Qty–Size (in.) 2, 4, 6, 8 Aluminum 118.13 1-57.50 x 168 1-43.75 x 168 1, 2, 3, 4, 6, 8 Aluminum or Copper 119.00 2-51 x 168 10 Aluminum 115.50 3-33 x 168 1 Aluminum or Copper 96.00 2-33 x 144 1-30 x 144 2, 4, 6, 8 Aluminum 91.88 1-42.50 x 168 1-36.25 x 168 1/2-inch unit coils -UA, UW, UF, UU (stacked) 5/8-inch unit coils -W, WD, 5D, 5A, 5W, D1, D2 (stacked) -W, WD, D1, D2 (stacked) 1-inch unit coil -NS (stacked) 1/2-inch modified coils -WL, LL, FD (stacked) CLCH-PRC022A-EN 153 General Data Table 138.Coil data for unit size 120 Coil Type Rows Fin Type Area ft² 1, 2, 3, 4, 6, 8 Aluminum or Copper 91.00 10 Aluminum 91.00 1 Aluminum or Copper 78.00 Qty–Size (in.) 5/8-inch modified coils -W, WD, 5A, 5W, D1, D2 (stacked) -W, WD, D1, D2 (stacked) 1-42 1-36 1-30 2-24 x x x x 168 168 168 168 1-inch modified coil -NS (stacked) Multizone coils 1-30 x 144 2-24 x 144 n/a n/a Table 139.Fan data for unit size 120 Housed Fans - Low Pressure Size/Type 40-in. FC 36-in. FC 32-in. FC 49-in. AF 44-in. AF 40-in. AF 36-in. AF Fan name 40FA 36FA 32FA 49AA 44AA 40AA 36AA Max rpm 550 600 675 800 850 1200 1250 ODP NEMA Premium motor hp range 30-40 30-40 30 30-100 30-40 30-60 30 Outlet area (ft²) 17.45 13.91 11.11 27.45 21.88 17.45 13.91 Bearing/Shaft size (in.) 2.44 2.44 2.19 2.75 2.94 2.19 2.44 Housed Fans - High Pressure Size/Type 40-in. FC 36-in. FC 32-in. FC 49-in. AF 44-in. AF 40-in. AF 36-in. AF Fan name 40FB 36FB 32FB 49AB 44AB 40AB 36AB Max rpm 600 665 760 1100 1150 1350 1550 ODP NEMA Premium motor hp range 30-75 30-75 30-60 30-125 30-125 30-100 30-75 Outlet area (ft²) 17.45 13.91 11.11 27.45 21.88 17.45 13.91 Bearing/Shaft size (in.) 2.44 2.44 2.19 2.94 2.94 2.44 2.44 Belt-drive Plenum Fans Low Pressure Direct-Drive Plenum Fans High Pressure High Pressure 6-24.5-in AF 6-24.5-in AF 55-in. AF Nominal Width Extended Width Size/Type 63-in. AF 55-in. AF 63-in. AF Fan name 63PA 55PA 63PB 55PB 24SF 24SW Max rpm 750 850 850 975 2344 2344 ODP NEMA Premium motor hp range 30-100 30-75 30-125 30-125 5-20 5-20 Outlet area (ft²) n/a n/a n/a n/a n/a n/a Bearing/Shaft size (in.) 2.94 2.44 3.19 2.94 n/a n/a 154 CLCH-PRC022A-EN Coils Drain Pans Table 140.Coil depth by rows (inches) Coil Rows Tube Diameter Unit Size 1 2 3 4 6 8 10 1/2 inch (unit height) 3-40, 22 n/a 6.55 n/a 6.55 8.72 10.88 n/a 1/2 inch (unit height) 50-120, 26, 31, 36, 41,51, 58 n/a 5.72 n/a 7.88 10.05 12.21 n/a 1/2 inch (modified Note: height)1 All sizes n/a 6.50 n/a 9/50 12.50 15.50 n/a 5/8 inch All sizes 4.00 6.50 8.00 9.50 12.50 15.50 18.50 1 inch All sizes 5.25 n/a n/a n/a n/a n/a n/a 1Modified coils include WL, LL, FD. 2 Unit coils include UF, UW, UU. Example: Size 30 with a 4-row UW coil in an extendedmedium coil section, there would be 10.82 inches of drain pan exposed beyond the coil casing for cleaning access. Coil Connections Hydronic and Steam Coil Connections Table 141.Water coils with 1/2-inch tubes connection diameter Connection Diameter (inches) Coil Type UW Rows 2, 4, 6, 8 Unit Sizes Quantity Supply Return 3-6 1 1.50 1.50 Drain/Vent 0.38 8-14, 50-66 1 2.00 2.00 0.38 17-40, 80-120 1 2.50 2.50 0.38 3-14, 50-57 1 1.50 1.50 0.38 UA 2 17-40, 66-120 1 2.00 2.00 0.38 UU 4, 8 12-120 1 2.50 2.50 0.38 LL 4, 6, 8 8-120 1 2.50 2.50 0.38 3-10 1 1.50 1.50 0.38 WL 2, 4, 6, 8 12-21, 66 1 2.00 2.00 0.38 25-57, 80-120 1 2.50 2.50 0.38 Note: All connections have external threads. Table 142.Water coils with 5/8-inch tubes connection diameter Coil Type Rows 5A 2 5D 6, 8, 10 1 5W 2 Connection Diameter (inches) Return Drain/Vent Header Height (in.) Supply 12-27 2.00 2.00 0.38 30-54 2.50 2.50 0.38 45-55 2.50 2.50 0.38 12-18 1.25 1.25 0.38 24-54 1.50 1.50 0.38 12-27 2.00 2.00 0.38 30-54 2.50 2.50 0.38 12-27 2.00 2.00 0.38 30-55 2.50 2.50 0.38 D1 3, 4, 6, 8, 10 D2 6, 8, 10 18-55 2.50 2.50 0.38 2, 6 12-30 0.75 0.75 0.50 4 12-30 1.00 1.00 0.50 2, 4, 6, 8 12-30 1.00 1.00 0.50 P2 P4 CLCH-PRC022A-EN 155 Coils Table 142.Water coils with 5/8-inch tubes connection diameter Connection Diameter (inches) Return Drain/Vent Coil Type Rows Header Height (in.) Supply P8 4, 8 18-30 1.25 1.25 TT 1, 2 12-33 0.75 0.75 n/a 12-27 2.00 2.00 0.38 24, 30-51 2.50 2.50 0.38 18-55 2.50 2.50 0.38 W 3, 4, 6, 8, 10 WD 6, 8, 10 0.50 Note: 5A, 5W, W (4–10 row), D1, D2, WD, and 5D connections have external threads; P2, P4, P8, and TT connections have internal threads. Table 143.Steam coils with 1-inch tubes connection diameter Coil Type Rows Header Height (in.) Supply NS 1 12 18 24 30–33 1.50 2.00 2.50 3.00 Connection Diameter (inches) Return Drain/Vent 1.00 1.00 1.25 1.25 1.00 1.00 1.25 1.25 Note: All connections have internal threads. Refrigerant Coil Connections Table 144.Type UF refrigerant coil connection sizes for unit sizes 3 to 30 Header Unit Height Size (inches) Connection Diameter (inches) Rows 4, 6, 8 3, 4 20 4, 6 4 4, 6, 8 6 26 4, 6 4 4, 6, 8 8, 10 28 4, 6 4 4, 6, 8 12, 14 32 4, 6 4 156 Distributor Number Tube of Circuits Circuiting 1 Distributor 2 Distributor 4 Distributor Liquid Suction Liquid Suction Liquid Suction n/a 0.25 15 Full n/a n/a 1.13 Note1 n/a 0.19 15 Full n/a n/a Note2 Note1 n/a n/a 0.25 7 Half 1.13 1.38 0.88 1.38 n/a n/a 0.19 7 Half 0.88 1.38 0.63 1.38 n/a n/a 0.25 3 Quarter 0.88 1.38 n/a n/a n/a n/a 0.19 3 Quarter 0.63 1.38 n/a n/a n/a n/a 0.25 20 Full n/a n/a 1.13 1.63 n/a n/a 0.19 20 Full n/a n/a 1.13 1.63 n/a n/a 0.25 10 Half 1.13 1.63 0.88 1.38 n/a n/a 0.19 10 Half 1.13 1.63 0.88 1.38 n/a n/a 0.25 5 Quarter 0.88 1.38 0.88 1.38 n/a n/a 0.19 5 Quarter 0.88 1.38 0.63 1.38 n/a n/a 0.25 22 Full n/a n/a 1.38 1.63 n/a n/a 0.19 22 Full n/a n/a 1.13 1.63 n/a n/a 0.25 11 Half 1.38 1.63 0.88 1.38 n/a n/a 0.19 11 Half 1.13 1.63 0.88 1.38 n/a n/a 0.25 4 Quarter 0.88 1.38 0.88 1.38 n/a n/a 0.19 4 Quarter 0.63 1.38 0.63 1.38 n/a n/a 0.25 25 Full n/a n/a 1.38 1.63 n/a n/a 0.19 25 Full n/a n/a 1.13 1.63 n/a n/a 0.25 12 Half 1.38 1.63 1.13 1.38 n/a n/a 0.19 12 Half 1.13 1.63 0.88 1.38 n/a n/a 0.25 6 Quarter 1.13 1.38 0.88 1.38 n/a n/a 0.19 6 Quarter 0.88 1.38 0.63 1.38 n/a n/a CLCH-PRC022A-EN Coils Table 144.Type UF refrigerant coil connection sizes for unit sizes 3 to 30 Header Unit Height Size (inches) Connection Diameter (inches) Rows 4, 6, 8 17 40 4, 6 4, 6, 8 21 43 4, 6 4, 6, 8 25, 30 52 4, 6 Notes: Distributor Number Tube of Circuits Circuiting 0.25 0.19 31 31 Full Full 1 Distributor 2 Distributor 4 Distributor Liquid Suction Liquid Suction Liquid Suction n/a n/a n/a n/a 1.13 Note5 n/a n/a Note4 Note5 n/a n/a 0.25 15 Half n/a n/a 1.13 Note7 0.88 1.38 0.19 15 Half n/a n/a Note6 Note7 0.63 1.38 0.25 34 Full n/a n/a n/a n/a 1.13 1.63 0.19 34 Full n/a n/a n/a n/a 1.13 1.63 0.25 17 Half n/a n/a 1.13 1.63 0.88 1.38 0.19 17 Half n/a n/a 1.13 1.63 Note8 1.38 0.25 41 Full n/a n/a n/a n/a 1.38 1.63 0.19 41 Full n/a n/a n/a n/a 1.13 1.63 0.25 20 Half n/a n/a 1.13 1.63 0.88 1.38 0.19 20 Half n/a n/a 1.13 1.63 0.88 1.38 1Bottom suction connection is 1.63 inches and top suction connection is 1.38 inch. 2Bottom liquid connection is 1.13 inches and top liquid connection is 0.88 inch. 3Connections are 1.13 for intertwined and 1.38 inches for horizontal split. 4Three connections are 1.13 inches and one is 0.88 inch. 5Three connections are 1.63 inches and one is 1.38 inches. 6One connection is 0.88 inch and one is 1.13 inches. 7One connection is 1.38 inches and one is 1.63 inches. 8Three connection are 0.63 inch and one is 0.88 inch. 9Liquid connections are 0.88 inch for intertwined and 1.13 inches for horizontal split. 10Suction connections are 1.38 inches for intertwined and 1.63 inches for horizontal split. 11Three suction connections are 1.38 inches and one is 1.63 inches. 12Three liquid connections are 0.88 inches and one is 1.13 inches. 13Three connections are 0.63 inches and one connection is 0.88 inches. Table 145.Type UF refrigerant coil connection sizes for unit sizes 35 to 120 Header Unit Height Size (inches) Connection Diameter (inches) Rows 4, 6, 8 35, 40 57 4, 6 4, 6, 8 50 31 4, 6 4 4, 6, 8 57 36 4, 6 4, 6, 8 66 37 4, 6 4, 6, 8 80 45 4, 6 CLCH-PRC022A-EN Distributor Number Tube of Circuits Circuiting 1 Distributor 2 Distributor 4 Distributor Liquid Suction Liquid Suction Liquid Suction 0.25 45 Full n/a n/a n/a n/a 1.38 1.63 0.19 45 Full n/a n/a n/a n/a 1.13 1.63 0.25 22 Half n/a n/a 1.38 1.63 1.38 1.63 0.19 22 Half n/a n/a 1.13 1.63 Note9 Note10 0.25 24 Full n/a n/a 1.38 1.63 n/a n/a 0.19 24 Full n/a n/a 1.13 1.63 n/a n/a 0.25 12 Half 1.38 1.63 1.13 1.38 n/a n/a 0.19 12 Half 1.13 1.63 0.88 1.38 n/a n/a 0.25 6 Quarter 1.13 1.38 0.88 1.38 n/a n/a 0.19 6 Quarter 0.88 1.38 0.63 1.38 n/a n/a 0.25 28 Full n/a n/a n/a n/a 1.13 1.38 0.19 28 Full n/a n/a n/a n/a 0.88 1.38 0.25 14 Half n/a n/a 1.13 1.38 n/a n/a 0.19 14 Half n/a n/a 0.88 1.38 n/a n/a 0.25 29 Full n/a n/a n/a n/a 1.13 Note11 0.19 29 Full n/a n/a n/a n/a Note12 Note11 0.25 14 Half n/a n/a 1.13 1.38 n/a n/a 0.19 14 Half n/a n/a 0.88 1.38 n/a n/a 0.25 35 Full n/a n/a n/a n/a 1.13 1.63 0.19 35 Full n/a n/a n/a n/a 1.13 1.63 0.25 17 Half n/a n/a 1.13 1.63 0.88 1.38 0.19 17 Half n/a n/a 1.13 1.63 Note13 1.38 157 Coils Table 145.Type UF refrigerant coil connection sizes for unit sizes 35 to 120 Header Unit Height Size (inches) Distributor Number Tube of Circuits Circuiting Rows 4, 6, 8 100, 120 Notes: Connection Diameter (inches) 51 4, 6 1 Distributor 2 Distributor 4 Distributor Liquid Suction Liquid Suction Liquid Suction 0.25 40 Full n/a n/a n/a n/a 1.13 1.63 0.19 40 Full n/a n/a n/a n/a 1.13 1.63 0.25 20 Half n/a n/a 1.13 1.63 0.88 1.38 0.19 20 Half n/a n/a 1.13 1.63 0.88 1.38 1Bottom suction connection is 1.63 inches and top suction connection is 1.38 inch. 2Bottom liquid connection is 1.13 inches and top liquid connection is 0.88 inch. 3Connections are 1.13 for intertwined and 1.38 inches for horizontal split. 4Three connections are 1.13 inches and one is 0.88 inch. 5Three connections are 1.63 inches and one is 1.38 inches. 6One connection is 0.88 inch and one is 1.13 inches. 7One connection is 1.38 inches and one is 1.63 inches. 8Three connection are 0.63 inch and one is 0.88 inch. 9Liquid connections are 0.88 inch for intertwined and 1.13 inches for horizontal split. 10Suction connections are 1.38 inches for intertwined and 1.63 inches for horizontal split. 11Three suction connections are 1.38 inches and one is 1.63 inches. 12Three liquid connections are 0.88 inches and one is 1.13 inches. 13Three connections are 0.63 inches and one connection is 0.88 inches. Table 146.Type FD refrigerant coil connection sizes for unit sizes 3 to 40 Header Height Unit Size (inches) Rows 4, 6 8, 10 18 4, 6 4 4, 6 12, 14 24 4, 6 4 4, 6 17 30 4, 6 4 4, 6 21 33 4, 6 4 25, 30, 35, 40 Notes: 158 36 4, 6 Number Distribut of or Tube Circuits Circuiting Connection Diameter (inches) 1 Distributor 2 Distributor 4 Distributor Liquid Suction Liquid Suction Liquid Suction n/a 0.25 14 Full n/a n/a 1.13 1.38 n/a 0.19 14 Full n/a n/a 0.88 1.38 n/a n/a 0.25 7 Half 1.13 1.38 0.88 1.38 n/a n/a 0.19 7 Half 0.88 1.38 0.63 1.38 n/a n/a 0.25 4 Quarter 0.88 1.38 0.88 1.38 n/a n/a 0.19 4 Quarter 0.63 1.38 0.63 1.38 n/a n/a 0.25 19 Full n/a n/a 1.13 1.63 n/a n/a 0.19 19 Full n/a n/a 1.13 1.63 n/a n/a 0.25 9 Half 1.13 1.63 0.88 1.63 n/a n/a 0.19 9 Half 1.13 1.63 Note1 1.63 n/a n/a 0.25 4 Quarter 0.88 1.38 0.88 1.38 n/a n/a 0.19 4 Quarter 0.63 1.38 0.63 1.38 n/a n/a 0.25 24 Full n/a n/a 1.38 1.63 n/a n/a 0.19 24 Full n/a n/a 1.13 1.63 n/a n/a 0.25 12 Half 1.38 1.63 1.13 1.63 n/a n/a 0.19 12 Half 1.13 1.63 0.88 1.63 n/a n/a 0.25 6 Quarter 1.13 1.63 0.88 1.63 n/a n/a 0.19 6 Quarter 0.88 1.63 0.63 1.63 n/a n/a 0.25 26 Full n/a n/a 1.38 1.63 n/a n/a 0.19 26 Full n/a n/a 1.13 1.63 n/a n/a 0.25 13 Half 1.38 1.63 1.13 1.63 n/a n/a 0.19 13 Half 1.13 1.63 0.88 1.63 n/a n/a 0.25 6 Quarter 1.13 1.63 0.88 1.63 n/a n/a 0.19 6 Quarter 0.88 1.63 0.63 1.63 n/a n/a 0.25 28 Full n/a n/a n/a n/a 1.13 1.38 0.19 28 Full n/a n/a n/a n/a 0.88 1.38 1On a 4 row intertwined the liquid connection is 0.88 inch downstream and 0.63 inch upstream. On a 6 row intertwined the liquid connection is 0.64 inch downstream and 0.88 upstream. 2For 4-row intertwined, the upstream liquid connection is 0.63 inches and the downstream liquid connection is 0.88 inches. For 6-row intertwined, the upstream liquid connection is 0.88 inches and the downstream liquid connection is 0.63 inches. CLCH-PRC022A-EN Coils Table 147. Type FD refrigerant coil connection sizes for unit sizes 50-120 Header Height Unit Size (inches) 50 Rows 42 4, 6 24 4, 6 24 4, 6 24 4 57 30 30 30 4, 6 4, 6 4 4, 6 66 24 4, 6 4 4, 6 66 33 4, 6 4 36 80 36 4, 6 4, 6 100 42 4, 6 36 4, 6 42 4, 6 120 Notes: Number of Distribut or Tube Circuits Circuiting Connection Diameter (inches) 1 Distributor 2 Distributor 4 Distributor Liquid Suction Liquid Suction Liquid Suction 0.25 33 Full n/a n/a n/a n/a 1.13 1.63 0.19 33 Full n/a n/a n/a n/a 1.13 1.63 0.25 19 Full n/a n/a 1.13 1.63 n/a n/a 0.19 19 Full n/a n/a 1.13 1.63 n/a n/a 0.25 9 Half 1.13 1.63 0.88 1.63 n/a n/a 0.19 9 Half 1.13 1.63 Note2 1.63 n/a n/a 0.25 4 Quarter 0.88 1.38 0.88 1.38 n/a n/a 0.19 4 Quarter 0.63 1.38 0.63 1.38 n/a n/a 0.25 24 Full n/a n/a 1.38 1.63 n/a n/a 0.19 24 Full n/a n/a 1.13 1.63 n/a n/a 0.25 12 Half 1.38 1.63 1.13 1.63 n/a n/a 0.19 12 Half 1.13 1.63 0.88 1.63 n/a n/a 0.25 6 Quarter 1.13 1.63 0.88 1.63 n/a n/a 0.19 6 Quarter 0.88 1.63 0.63 1.63 n/a n/a 0.25 19 Full n/a n/a 1.13 1.63 n/a n/a 0.19 19 Full n/a n/a 1.13 1.63 n/a n/a 0.25 9 Half 1.13 1.63 0.88 1.63 n/a n/a 0.19 9 Half 1.13 1.63 Note2 1.63 n/a n/a 0.25 4 Quarter 0.88 1.38 0.88 1.38 n/a n/a 0.19 4 Quarter 0.63 1.38 0.63 1.38 n/a n/a 0.25 26 Full n/a n/a 1.38 1.63 n/a n/a 0.19 26 Full n/a n/a 1.13 1.63 n/a n/a 0.25 13 Half 1.38 1.63 1.13 1.63 n/a n/a 0.19 13 Half 1.13 1.63 0.88 1.63 n/a n/a 0.25 6 Quarter 1.13 1.63 0.88 1.63 n/a n/a 0.19 6 Quarter 0.88 1.63 0.63 1.63 n/a n/a 0.25 28 Full n/a n/a n/a n/a 1.13 1.38 0.19 28 Full n/a n/a n/a n/a 0.88 1.38 0.25 28 Full n/a n/a n/a n/a 1.13 1.38 0.19 28 Full n/a n/a n/a n/a 0.88 1.38 0.25 33 Full n/a n/a n/a n/a 1.13 1.63 0.19 33 Full n/a n/a n/a n/a 1.13 1.63 0.25 28 Full n/a n/a n/a n/a 1.13 1.38 0.19 28 Full n/a n/a n/a n/a 0.88 1.38 0.25 33 Full n/a n/a n/a n/a 1.13 1.63 0.19 33 Full n/a n/a n/a n/a 1.13 1.63 1On a 4 row intertwined the liquid connection is 0.88 inch downstream and 0.63 inch upstream. On a 6 row intertwined the liquid connection is 0.64 inch downstream and 0.88 upstream. 2For 4-row intertwined, the upstream liquid connection is 0.63 inches and the downstream liquid connection is 0.88 inches. For 6-row intertwined, the upstream liquid connection is 0.88 inches and the downstream liquid connection is 0.63 inches. CLCH-PRC022A-EN 159 Coils Coil Circuiting Refrigerant coil circuiting is first defined by how the distributors are arranged on the coil and then by the number of tubes on the coil being fed refrigerant. Distributor Arrangement The term standard circuiting means the number of distributors used on a coil is the minimum required to meet capacity. If more than one distributor is required, then the coil is horizontally split so sections of the coil can be de-energized to unload the coil. The term horizontally split circuiting means that at a minimum, each coil (or each coil in a bank) will have two or more distributors per coil. As each coil is horizontally split, sections of the coil can be de-energized to unload the coil. The term intertwined circuiting means that at a minimum each coil (or each coil in a bank) will have two or more distributors per coil. Since each distributor is circuited from the top to the bottom of the coil, the full face of the coil remains energized even if a circuit is de-energized to unload the coil. If four distributors are used on a coil, then the coil is first horizontally split, with the top half of the coil intertwined using two distributors, and the bottom half of the coil intertwined using the other two distributors. Distributor Circuiting The terms full, half, and quarter refer to the number of coil tubes being fed refrigerant by each distributor of that coil. For example, full means that each tube in one row of the coil is being fed refrigerant from the distributor(s), while half means every other tube in a row is being fed. Circuiting Example. Table 148 lists standard distributor arrangements (minimum number or distributors) for UF coils. On a size 12 unit, 6-row coil with half circuiting (every other tube in a row being fed), there is one distributor, with 12 tubes in one row of the coil being fed refrigerant. Circuiting data is show by unit size and coil rows. Table 148.Type UF coil standard circuiting Unit size 3,4 6 8,10 12,14 17 160 Header height (inches) 20 26 28 32 40 Full Half Quarter Coil rows Dist qty Circuits per dist Dist qty Circuits per dist Dist qty Circuits per dist 4 2 7,8 1 7 1 3 6 2 7,8 1 7 n/a n/a 8 2 7,8 n/a n/a n/a n/a 4 2 10,10 1 10 1 5 6 2 10,10 1 10 n/a n/a 8 2 10,10 n/a n/a n/a n/a 4 2 11,11 1 11 1 4 6 2 11,11 1 11 n/a n/a 8 2 11,11 n/a n/a n/a n/a 4 2 12,13 1 12 1 6 6 2 12,13 1 12 n/a n/a 4 4 7,8,8,8 2 7,8 n/a n/a 6 4 7,8,8,8 2 7,8 n/a n/a 8 4 7,8,8,8 n/a n/a n/a n/a CLCH-PRC022A-EN Coils Table 148.Type UF coil standard circuiting Unit size 21 25,30 35,40 Header height (inches) 43 52 57 31 50 (Stacked) 31 36 57 (Stacked) 36 37 66 (Stacked) 37 45 80 (Stacked) 45 51 100, 120 (Stacked) 51 CLCH-PRC022A-EN Full Half Quarter Coil rows Dist qty Circuits per dist Dist qty Circuits per dist Dist qty 4 4 8,8,9,9 2 8,9 n/a n/a 6 4 8,8,9,9 2 8,9 n/a n/a Circuits per dist 8 4 8,8,9,9 n/a n/a n/a n/a 4 4 10,10,10,11 2 10,10 n/a n/a 6 4 10,10,10,11 2 10,10 n/a n/a 8 4 10,10,10,11 n/a n/a n/a n/a 4 4 11,11,11,12 2 11,11 n/a n/a 6 4 11,11,11,12 2 11,11 n/a n/a 8 4 11,11,11,12 n/a n/a n/a n/a 4 2 12,12 1 12 1 6 6 2 12,12 1 12 n/a n/a 8 2 12,12 n/a n/a n/a n/a 4 2 12,12 1 12 1 6 6 2 12,12 1 12 n/a n/a 8 2 12,12 n/a n/a n/a n/a 4 4 7,7,7,7 2 7,7 n/a n/a 6 4 7,7,7,7 2 7,7 n/a n/a 8 4 7,7,7,7 n/a n/a n/a n/a 4 4 7,7,7,7 2 7,7 n/a n/a 6 4 7,7,7,7 2 7,7 n/a n/a 8 4 7,7,7,7 n/a n/a n/a n/a 4 4 7,7,7,8 2 7,7 n/a n/a 6 4 7,7,7,8 2 7,7 n/a n/a 8 4 7,7,7,8 n/a n/a n/a n/a 4 4 7,7,7,8 2 7,7 n/a n/a 6 4 7,7,7,8 2 7,7 n/a n/a 8 4 7,7,7,8 n/a n/a n/a n/a 4 4 8,9,9,9 2 8,9 n/a n/a 6 4 8,9,9,9 2 8,9 n/a n/a 8 4 8,9,9,9 n/a n/a n/a n/a 4 4 8,9,9,9 2 8,9 n/a n/a 6 4 8,9,9,9 2 8,9 n/a n/a 8 4 8,9,9,9 n/a n/a n/a n/a 4 4 10,10,10,10 2 10,10 n/a n/a 6 4 10,10,10,10 2 10,10 n/a n/a 8 4 10,10,10,10 n/a n/a n/a n/a 4 4 10,10,10,10 2 10,10 n/a n/a 6 4 10,10,10,10 2 10,10 n/a n/a 8 4 10,10,10,10 n/a n/a n/a n/a 161 Coils Table 149.Type UF coil intertwined circuiting Unit Size Header Height (inches) 3, 4 20 6 26 8, 10 12, 14 17 21 25, 30 35, 40 28 32 40 43 52 57 31 50 (Stacked) 31 36 57 (Stacked) 36 37 66 (Stacked) 37 162 Full Circuits per Dist Half Circuits per Dist Qty Dist Quarter Circuits per Dist Qty Dist Coil Rows Dist Qty 4, 6 2 7, 8 2 3, 4 n/a n/a 8 2 7, 8 n/a n/a n/a n/a 4 2 10, 10 2 5, 5 2 2, 3 6 2 10, 10 2 5, 5 n/a n/a 8 2 10, 10 n/a n/a n/a n/a 4 2 11, 11 2 5, 6 2 2, 2 6 2 11, 11 2 5, 6 n/a n/a 8 2 11, 11 n/a n/a n/a n/a 4 2 12, 13 2 6, 6 2 3, 3 6 2 12, 13 2 6, 6 n/a n/a 8 2 12, 13 n/a n/a n/a n/a 4, 6 4 8, 7, 8, 8 4 4, 3, 4, 4 n/a n/a 8 4 8, 7, 8, 8 n/a n/a n/a n/a 4, 6 4 8, 8, 9, 9 4 4, 4, 4, 5 n/a n/a 8 4 8, 8, 9, 9 n/a n/a n/a n/a 4, 6 4 10, 10, 10, 11 4 5, 5, 5, 5 n/a n/a 8 4 10, 10, 10, 11 n/a n/a n/a n/a 4, 6 4 11, 11, 11, 12 4 5, 6, 5, 6 n/a n/a 8 4 11, 11, 11, 12 n/a n/a n/a n/a 4 2 12,12 2 6,6 2 3,3 6 2 12,12 2 6,6 n/a n/a 8 2 12,12 n/a n/a n/a n/a 4 2 12,12 2 6,6 2 3,3 6 2 12,12 2 6,6 n/a n/a 8 2 12,12 n/a n/a n/a n/a 4 4 7,7,7,7 2 7,7 n/a n/a 6 4 7,7,7,7 2 7,7 n/a n/a 8 4 7,7,7,7 n/a n/a n/a n/a 4 4 7,7,7,7 2 7,7 n/a n/a 6 4 7,7,7,7 2 7,7 n/a n/a 8 4 7,7,7,7 n/a n/a n/a n/a 4 4 7,7,7,8 2 7,7 n/a n/a 6 4 7,7,7,8 2 7,7 n/a n/a 8 4 7,7,7,8 n/a n/a n/a n/a 4 4 7,7,7,8 2 7,7 n/a n/a 6 4 7,7,7,8 2 7,7 n/a n/a 8 4 7,7,7,8 n/a n/a n/a n/a CLCH-PRC022A-EN Coils Table 149.Type UF coil intertwined circuiting Unit Size Header Height (inches) 45 80 (Stacked) 45 51 100, 120 (Stacked) 51 Full Circuits per Dist Half Circuits per Dist Dist Qty Quarter Circuits per Dist Dist Qty Coil Rows Dist Qty 4 4 8,9,9,9 4 4,4,4,5 n/a n/a 6 4 8,9,9,9 4 4,4,4,5 n/a n/a 8 4 8,9,9,9 n/a n/a n/a n/a 4 4 8,9,9,9 4 4,4,4,5 n/a n/a 6 4 8,9,9,9 4 4,4,4,5 n/a n/a 8 4 8,9,9,9 n/a n/a n/a n/a 4 4 10,10,10,10 4 5,5,5,5 n/a n/a 6 4 10,10,10,10 4 5,5,5,5 n/a n/a 8 4 10,10,10,10 n/a n/a n/a n/a 4 4 10,10,10,10 4 5,5,5,5 n/a n/a 6 4 10,10,10,10 4 5,5,5,5 n/a n/a 8 4 10,10,10,10 n/a n/a n/a n/a Table 150. Type FD coil standard circuiting Unit Size 8,10 12,14 Full Header height (inches) Coil rows Dist qty Circuits per dist 18 24 17 30 21 33 25, 30, 35, 40 36 50 42 24 57 (Stacked) 30 24 66 (Stacked) 33 CLCH-PRC022A-EN Half Quarter Dist qty Circuits per dist Dist qty Circuits per dist 7,7 1 7 1 4 2 7,7 1 7 n/a n/a 2 9,10 1 9 1 4 2 9,10 1 9 n/a n/a 2 12,12 1 12 1 6 2 12,12 1 12 n/a n/a 4 2 6 4 6 4 6 4 2 13,13 1 13 1 6 6 2 13,13 1 13 n/a n/a 4 4 7,7,7,7 n/a n/a n/a n/a 6 4 7,7,7,7 n/a n/a n/a n/a 4 4 8,8,8,9 n/a n/a n/a n/a 6 4 8,8,8,9 n/a n/a n/a n/a 4 2 9,10 1 9 1 4 6 2 9,10 1 9 n/a n/a 4 2 12,12 1 12 1 6 6 2 12,12 1 12 n/a n/a 4 2 9,10 1 9 1 4 6 2 9,10 1 9 n/a n/a 4 2 13,13 1 13 1 6 6 2 13,13 1 13 n/a n/a 163 Coils Table 150. Type FD coil standard circuiting Unit Size Full Header height (inches) Coil rows Dist qty Circuits per dist 36 80 (Stacked) 36 36 100, 120 (Stacked) 42 Half Quarter Dist qty Circuits per dist Dist qty Circuits per dist 4 4 7,7,7,7 n/a n/a n/a n/a 6 4 7,7,7,7 n/a n/a n/a n/a 4 4 7,7,7,7 n/a n/a n/a n/a 6 4 7,7,7,7 n/a n/a n/a n/a 4 4 7,7,7,7 n/a n/a n/a n/a 6 4 7,7,7,7 n/a n/a n/a n/a 4 4 8,8,8,9 n/a n/a n/a n/a 6 4 8,8,8,9 n/a n/a n/a n/a Table 151.Type FD coil intertwined circuiting Unit Size Header Height (inches) 8, 10 18 12, 14 24 17 21 30 33 25, 30, 35, 40 36 50 42 57 24 (Stacked) 30 66 24 (Stacked) 33 80 36 (Stacked) 36 100, 120 36 (Stacked) 42 164 Coil Rows Full Circuits per Dist Qty Dist Half Circuits per Dist Qty Dist Quarter Circuits per Dist Qty Dist 4 2 7, 7 2 3, 4 2 2, 2 6 2 7, 7 2 3, 4 n/a n/a 2, 2 4 2 10, 9 2 4, 5 2 6 2 10, 9 2 4, 5 n/a n/a 4 2 12, 12 2 6, 6 2 3, 3 6 2 12, 12 2 6, 6 n/a n/a 4 2 13, 13 2 6, 7 2 3, 3 6 2 13, 13 2 6, 7 n/a n/a 4 4 7, 7, 7, 7 n/a n/a n/a n/a 6 4 7, 7, 7, 7 n/a n/a n/a n/a 4 4 8, 9, 8, 8 n/a n/a n/a n/a 6 4 8, 9, 8, 8 n/a n/a n/a n/a 4 2 10, 9 2 4, 5 2 2, 2 6 2 10, 9 2 4, 5 n/a n/a 4 2 12, 12 2 6, 6 2 3, 3 6 2 12, 12 2 6, 6 n/a n/a 4 2 10, 9 2 4, 5 2 2, 2 6 2 10, 9 2 4, 5 n/a n/a 4 2 13, 13 2 6, 7 2 3, 3 n/a 6 2 13, 13 2 6, 7 n/a 4 4 7, 7, 7, 7 n/a n/a n/a n/a 6 4 7, 7, 7, 7 n/a n/a n/a n/a 4 4 7, 7, 7, 7 n/a n/a n/a n/a 6 4 7, 7, 7, 7 n/a n/a n/a n/a 4 4 7, 7, 7, 7 n/a n/a n/a n/a 6 4 7, 7, 7, 7 n/a n/a n/a n/a 4 4 8, 9, 8, 8 n/a n/a n/a n/a 6 4 8, 9, 8, 8 n/a n/a n/a n/a CLCH-PRC022A-EN Coils Face-Velocity Limits for Moisture Carryover Cooling coils are available with a wide variety of fin types and materials, including the following, to help optimize their performance: • 1/2-inch: Delta-Flo™ E and Delta-Flo H aluminum fins • 5/8-inch: Prima-Flo™ E and Prima-Flo H aluminum fins, and Prima-Flo™ copper fins All of these fins are available with variable fin spacing (that is, the spacing can increment by as little as one fin per foot). Also, Delta-Flo H and Prima-Flo H fins are specifically designed to help maximize heat transfer while minimizing moisture carryover. Figure 65 through Figure 72 detail the moisture carryover limits for each of these fin types. Refer to TOPSS selection program for availability. Figure 65. Face-velocity limits for moisture carryover with uncoated coils in unit sizes 3 to 10 Delta-Flo E Delta-Flo H Prima-Flo E Prima-Flo H Prima-Flo Cu 800 750 700 Face Velocity (sfpm) 650 600 550 500 450 400 350 300 250 200 70 80 90 100 110 120 130 140 150 160 170 180 Fin Series (fins/ft) CLCH-PRC022A-EN 165 Coils Figure 66. Face-velocity limits for moisture carryover with uncoated coils in unit size 12 Delta-Flo E Delta-Flo H Prima-Flo E Prima-Flo H Prima-Flo Cu 800 750 700 Face Velocity (sfpm) 650 600 550 500 450 400 350 300 250 200 70 80 90 100 110 120 130 140 150 160 170 180 Fin Series (fins/ft) Figure 67. Face velocity limits for moisture carryover with uncoated coils in unit sizes 14 to 17 Delta-Flo E Delta-Flo H Prima-Flo E Prima-Flo H Prima-Flo Cu 800 750 700 Face Velocity (sfpm) 650 600 550 500 450 400 350 300 250 200 70 80 90 100 110 120 130 140 150 160 170 180 Fin Series (fins/ft) 166 CLCH-PRC022A-EN Coils Figure 68. Face velocity limits for moisture carryover with uncoated coils in unit sizes 21 to 30 Delta-Flo E Delta-Flo H Prima-Flo E Prima-Flo H Prima-Flo Cu 800 750 700 Face Velocity (sfpm) 650 600 550 500 450 400 350 300 250 200 70 80 90 100 110 120 130 140 150 160 170 180 Fin Series (fins/ft) Figure 69. Face velocity limits for moisture carryover with uncoated coils in unit sizes 35 and 40 Delta-Flo E Delta-Flo H Prima-Flo E Prima-Flo H Prima-Flo Cu 800 750 700 Face Velocity (sfpm) 650 600 550 500 450 400 350 300 250 200 70 80 90 100 110 120 130 140 150 160 170 180 Fin Series (fins/ft) CLCH-PRC022A-EN 167 Coils Figure 70. Face velocity limits for moisture carryover with uncoated coils in unit sizes 50 to 57 Delta-Flo E Delta-Flo H Prima-Flo E Prima-Flo H Prima-Flo Cu 800 750 700 Face Velocity (sfpm) 650 600 550 500 450 400 350 300 250 200 70 80 90 100 110 120 130 140 150 160 170 180 Fin Series (fins/ft) Figure 71. Face velocity limits for moisture carryover with uncoated coils in unit size 66 Delta-Flo E Delta-Flo H Prima-Flo E Prima-Flo H Prima-Flo Cu 800 750 700 Face Velocity (sfpm) 650 600 550 500 450 400 350 300 250 200 70 80 90 100 110 120 130 140 150 160 170 180 Fin Series (fins/ft) 168 CLCH-PRC022A-EN Coils Figure 72. Face velocity limits for moisture carryover with uncoated coils in unit sizes 80 to 120 Delta-Flo E Delta-Flo H Prima-Flo E Prima-Flo H Prima-Flo Cu 800 750 700 Face Velocity (sfpm) 650 600 550 500 450 400 350 300 250 200 70 80 90 100 110 120 130 140 150 160 170 180 Fin Se rie s (fins/ft) CLCH-PRC022A-EN 169 Performance Data Air-to-Air Plate Heat Exchangers Table 152. Air-to-air plate heat exchanger performance data Bypass exchanger High efficiency exchanger Low efficiency exchanger % sensible Pressure drop % sensible Pressure drop % sensible Pressure drop effectiveness (in w.g.) effectiveness (in w.g.) effectiveness (in w.g.) Unit size Nominal airflow* cfm Plate spacing Wide 50 0.35 56 0.24 n/a n/a 3 1500 Medium 58 0.59 60 0.32 n/a n/a Close 65 1.21 66 0.67 n/a n/a Wide 52 0.26 57 0.18 n/a n/a 4 6 8 10 12 14 17 21 25 30 35 40 50 2000 3000 4000 5000 6000 7000 8500 10500 12500 15000 17500 20000 25000 Medium 59 0.40 60 0.25 n/a n/a Close 66 0.83 66 0.54 n/a n/a Wide 53 0.42 55 0.23 n/a n/a Medium 60 0.58 65 0.43 n/a n/a Close 64 0.76 69 0.89 n/a n/a Wide 53 0.48 54 0.29 n/a n/a Medium 60 0.66 64 0.54 n/a n/a Close 63 0.87 69 1.10 n/a n/a Wide 58 0.37 59 0.22 49 0.39 Medium 61 0.52 62 0.33 54 0.52 Close 66 0.87 67 0.56 58 0.66 Wide 57 0.44 59 0.27 54 0.35 Medium 61 0.62 62 0.39 61 0.49 Close 66 1.01 67 0.66 64 0.64 Wide 57 0.49 58 0.31 54 0.39 Medium 60 0.69 62 0.44 60 0.55 Close 66 1.12 67 0.74 64 0.72 Wide 63 0.65 64 0.42 57 0.45 0.63 Medium 67 0.87 68 0.56 61 Close 69 1.13 70 0.75 66 1.03 Wide 63 0.73 64 0.50 61 0.43 Medium 64 0.86 68 0.66 64 0.53 Close 67 0.97 70 0.88 68 0.73 Wide 59 0.78 60 0.50 63 0.68 0.81 Medium 66 0.84 67 0.54 65 Close 69 0.99 70 0.63 67 0.91 Wide 59 0.78 60 0.51 63 0.70 Medium 66 0.84 67 0.55 65 0.82 Close 69 0.98 70 0.65 67 0.93 Wide 59 0.87 60 0.59 n/a n/a Medium 66 0.94 67 0.64 n/a n/a Close 69 1.09 69 0.75 n/a n/a Wide 59 0.87 60 0.60 n/a n/a Medium 66 0.94 67 0.65 n/a n/a Close 69 1.10 69 0.76 n/a n/a Wide n/a n/a n/a n/a 59 0.72 Medium n/a n/a n/a n/a 66 0.78 Close n/a n/a n/a n/a 69 0.92 Note: *Stated performance is based on a dry exchanger with the exhaust and ventilation airflow rate equal to the nominal airflow. Performance will vary based on airflow conditions, utilize TOPSS for application specific performance. 170 CLCH-PRC022A-EN Performance Data Table 153. Air-to-air plate heat exchanger bypass damper performance data Static Pressure Drop (inches w.g.) by face velocity (fpm) Unit size Face Area (ft2) 800 1000 1200 1400 1600 1800 3 1.17 0.23 0.36 0.52 0.71 0.93 1.18 4 1.34 0.23 0.36 0.52 0.71 0.93 1.18 6 2.07 0.17 0.26 0.38 0.52 0.67 0.85 1.05 1.27 8 2.07 0.17 0.26 0.38 0.52 0.67 0.85 1.05 1.27 10 2.96 0.15 0.23 0.33 0.45 0.59 0.75 0.92 1.12 1.33 12 3.21 0.14 0.22 0.32 0.44 0.57 0.72 0.89 1.08 1.28 14 3.45 0.14 0.22 0.31 0.42 0.55 0.70 0.86 1.05 1.25 17 4.43 0.13 0.21 0.30 0.41 0.53 0.67 0.83 1.00 1.19 21 4.43 0.13 0.21 0.30 0.41 0.53 0.67 0.83 1.00 1.19 25 6.34 0.12 0.19 0.28 0.38 0.49 0.62 0.77 0.93 1.11 30 7.14 0.12 0.19 0.27 0.36 0.47 0.60 0.74 0.90 1.07 1.25 35 7.14 0.12 0.19 0.27 0.36 0.47 0.60 0.74 0.90 1.07 1.25 40 7.93 0.12 0.18 0.26 0.35 0.46 0.58 0.72 0.87 1.04 1.22 2000 2200 2400 2600 1.30 Blenders Table 154. Blender performance data Static Pressure Drop (inches w.g.) by Plenum Face Velocity (fpm) Unit size Area (ft2) 200 250 300 350 400 450 500 550 600 3 1.90 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.20 0.24 4 2.30 0.04 0.07 0.10 0.13 0.17 0.21 0.27 0.32 0.38 6 3.30 0.03 0.05 0.07 0.10 0.13 0.16 0.20 0.24 0.28 8 3.90 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.34 10 4.50 0.04 0.07 0.10 0.14 0.18 0.23 0.28 0.34 0.40 12 5.90 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.33 14 5.80 0.05 0.08 0.11 0.15 0.19 0.24 0.30 0.36 0.43 17 9.00 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.19 0.23 21 10.40 0.03 0.05 0.06 0.09 0.12 0.15 0.18 0.22 0.26 22 9.20 0.04 0.06 0.09 0.12 0.16 0.20 0.24 0.30 0.35 25 11.80 0.03 0.05 0.07 0.10 0.13 0.17 0.20 0.25 0.29 26 11.10 0.05 0.07 0.11 0.15 0.19 0.24 0.30 0.36 0.43 30 15.00 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 31 13.25 0.05 0.07 0.10 0.14 0.19 0.24 0.29 0.35 0.42 35 15.00 0.04 0.07 0.09 0.13 0.17 0.21 0.26 0.32 0.38 36 15.60 0.05 0.07 0.10 0.14 0.18 0.23 0.28 0.34 0.41 40 17.70 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.33 41 18.00 0.05 0.08 0.11 0.15 0.19 0.25 0.30 0.37 0.44 50 22.50 0.04 0.06 0.08 0.12 0.15 0.19 0.24 0.28 0.34 51 25.10 0.03 0.05 0.07 0.10 0.12 0.16 0.19 0.23 0.28 57 24.90 0.04 0.06 0.09 0.12 0.16 0.21 0.25 0.31 0.37 CLCH-PRC022A-EN 171 Performance Data Table 154. Blender performance data Static Pressure Drop (inches w.g.) by Plenum Face Velocity (fpm) Unit size Area (ft2) 200 250 300 350 400 450 500 550 600 58 25.10 0.04 0.07 0.10 0.13 0.17 0.21 0.27 0.32 0.38 66 27.60 0.05 0.07 0.11 0.15 0.19 0.24 0.30 0.36 0.43 80 30.30 0.06 0.09 0.13 0.18 0.23 0.29 0.36 0.43 0.52 100 39.90 0.05 0.08 0.11 0.15 0.20 0.25 0.31 0.37 0.44 120 54.00 0.03 0.05 0.08 0.11 0.14 0.17 0.22 0.26 0.31 Dampers Energy Wheel Dampers Table 155. Energy wheel recirculation damper performance data Unducted Pressure Drop Unit size Area (ft2) 400 500 600 700 800 900 3 2.21 0.04 0.06 0.09 0.12 0.16 0.20 0.25 0.30 0.36 0.48 0.63 0.80 0.99 1.20 1.42 1.67 4 2.76 0.04 0.06 0.08 0.12 0.15 0.19 0.24 0.29 0.34 0.46 0.60 0.76 0.94 1.14 1.36 1.59 6 2.76 0.04 0.06 0.08 0.12 0.15 0.19 0.24 0.29 0.34 0.46 0.60 0.76 0.94 1.14 1.36 1.59 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 8 3.40 0.04 0.06 0.08 0.11 0.15 0.18 0.23 0.28 0.33 0.45 0.58 0.74 0.91 1.10 1.31 1.54 10 4.46 0.04 0.06 0.08 0.11 0.14 0.18 0.22 0.27 0.32 0.43 0.56 0.71 0.88 1.07 1.27 1.49 12 4.95 0.03 0.05 0.08 0.11 0.14 0.18 0.22 0.26 0.31 0.43 0.56 0.71 0.87 1.06 1.26 1.47 14 5.48 0.03 0.05 0.08 0.11 0.14 0.17 0.22 0.26 0.31 0.42 0.55 0.70 0.86 1.05 1.24 1.46 17 5.48 0.03 0.05 0.08 0.11 0.14 0.17 0.22 0.26 0.31 0.42 0.55 0.70 0.86 1.05 1.24 1.46 21 6.26 0.04 0.06 0.09 0.12 0.16 0.20 0.25 0.30 0.35 0.48 0.63 0.79 0.98 1.19 1.41 1.66 25 6.26 0.04 0.06 0.09 0.12 0.16 0.20 0.25 0.30 0.35 0.48 0.63 0.79 0.98 1.19 1.41 1.66 30 7.57 0.04 0.06 0.08 0.12 0.15 0.19 0.24 0.29 0.34 0.46 0.60 0.76 0.94 1.14 1.36 1.59 35 8.20 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.34 0.46 0.60 0.75 0.93 1.13 1.34 1.57 40 9.41 0.04 0.06 0.08 0.11 0.15 0.18 0.23 0.28 0.33 0.45 0.58 0.74 0.91 1.10 1.31 1.54 50 10.67 0.04 0.06 0.08 0.11 0.14 0.18 0.22 0.27 0.32 0.44 0.57 0.73 0.90 1.08 1.29 1.51 Table 156. Energy wheel bypass damper performance data Wheel Unit nominal cfm size Unducted Pressure Drop Area (ft2) 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 4 900 1.03 0.04 0.07 0.09 0.13 0.17 0.21 0.26 0.32 0.38 0.51 0.67 0.85 1.05 1.27 1.51 1.77 4 1500 1.03 0.04 0.07 0.09 0.13 0.17 0.21 0.26 0.32 0.38 0.51 0.67 0.85 1.05 1.27 1.51 1.77 4 2200 1.03 0.04 0.07 0.09 0.13 0.17 0.21 0.26 0.32 0.38 0.51 0.67 0.85 1.05 1.27 1.51 1.77 6 900 1.03 0.04 0.07 0.09 0.13 0.17 0.21 0.26 0.32 0.38 0.51 0.67 0.85 1.05 1.27 1.51 1.77 6 1500 1.03 0.04 0.07 0.09 0.13 0.17 0.21 0.26 0.32 0.38 0.51 0.67 0.85 1.05 1.27 1.51 1.77 6 2200 1.03 0.04 0.07 0.09 0.13 0.17 0.21 0.26 0.32 0.38 0.51 0.67 0.85 1.05 1.27 1.51 1.77 8 1500 1.83 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.33 0.45 0.59 0.75 0.92 1.12 1.33 1.56 8 2200 1.03 0.04 0.07 0.09 0.13 0.17 0.21 0.26 0.32 0.38 0.51 0.67 0.85 1.05 1.27 1.51 1.77 8 3000 1.83 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.33 0.45 0.59 0.75 0.92 1.12 1.33 1.56 172 CLCH-PRC022A-EN Performance Data Table 156. Energy wheel bypass damper performance data Wheel Unit nominal size cfm Area (ft2) Unducted Pressure Drop 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 10 2200 1.83 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.33 0.45 0.59 0.75 0.92 1.12 1.33 1.56 10 3000 1.83 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.33 0.45 0.59 0.75 0.92 1.12 1.33 1.56 10 4000 2.38 0.04 0.06 0.08 0.11 0.14 0.18 0.22 0.27 0.32 0.44 0.57 0.72 0.89 1.08 1.28 1.50 10 5000 2.38 0.04 0.06 0.08 0.11 0.14 0.18 0.22 0.27 0.32 0.44 0.57 0.72 0.89 1.08 1.28 1.50 12 2200 1.83 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.33 0.45 0.59 0.75 0.92 1.12 1.33 1.56 12 3000 1.83 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.33 0.45 0.59 0.75 0.92 1.12 1.33 1.56 12 4000 2.38 0.04 0.06 0.08 0.11 0.14 0.18 0.22 0.27 0.32 0.44 0.57 0.72 0.89 1.08 1.28 1.50 12 5000 3.05 0.03 0.05 0.08 0.11 0.14 0.18 0.22 0.26 0.31 0.42 0.55 0.70 0.87 1.05 1.25 1.46 12 6000 3.05 0.03 0.05 0.08 0.11 0.14 0.18 0.22 0.26 0.31 0.42 0.55 0.70 0.87 1.05 1.25 1.46 14 2200 2.38 0.04 0.06 0.08 0.11 0.14 0.18 0.22 0.27 0.32 0.44 0.57 0.72 0.89 1.08 1.28 1.50 14 3000 1.83 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.33 0.45 0.59 0.75 0.92 1.12 1.33 1.56 14 4000 2.38 0.04 0.06 0.08 0.11 0.14 0.18 0.22 0.27 0.32 0.44 0.57 0.72 0.89 1.08 1.28 1.50 14 5000 3.05 0.03 0.05 0.08 0.11 0.14 0.18 0.22 0.26 0.31 0.42 0.55 0.70 0.87 1.05 1.25 1.46 14 6000 3.05 0.03 0.05 0.08 0.11 0.14 0.18 0.22 0.26 0.31 0.42 0.55 0.70 0.87 1.05 1.25 1.46 14 7000 3.05 0.03 0.05 0.08 0.11 0.14 0.18 0.22 0.26 0.31 0.42 0.55 0.70 0.87 1.05 1.25 1.46 17 3000 3.05 0.03 0.05 0.08 0.11 0.14 0.18 0.22 0.26 0.31 0.42 0.55 0.70 0.87 1.05 1.25 1.46 17 4000 2.38 0.04 0.06 0.08 0.11 0.14 0.18 0.22 0.27 0.32 0.44 0.57 0.72 0.89 1.08 1.28 1.50 17 5000 3.05 0.03 0.05 0.08 0.11 0.14 0.18 0.22 0.26 0.31 0.42 0.55 0.70 0.87 1.05 1.25 1.46 17 6000 3.51 0.03 0.05 0.08 0.10 0.14 0.17 0.21 0.26 0.31 0.42 0.55 0.69 0.86 1.04 1.23 1.45 17 7000 3.51 0.03 0.05 0.08 0.10 0.14 0.17 0.21 0.26 0.31 0.42 0.55 0.69 0.86 1.04 1.23 1.45 21 3000 3.05 0.03 0.05 0.08 0.11 0.14 0.18 0.22 0.26 0.31 0.42 0.55 0.70 0.87 1.05 1.25 1.46 21 4000 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 21 5000 3.05 0.03 0.05 0.08 0.11 0.14 0.18 0.22 0.26 0.31 0.42 0.55 0.70 0.87 1.05 1.25 1.46 21 6000 3.51 0.03 0.05 0.08 0.10 0.14 0.17 0.21 0.26 0.31 0.42 0.55 0.69 0.86 1.04 1.23 1.45 21 7000 3.77 0.03 0.05 0.08 0.10 0.14 0.17 0.21 0.26 0.31 0.42 0.54 0.69 0.85 1.03 1.23 1.44 21 8500 4.00 0.04 0.06 0.09 0.12 0.15 0.19 0.24 0.29 0.35 0.47 0.62 0.78 0.96 1.16 1.38 1.62 25 4000 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 25 5000 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 25 6000 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 25 7000 3.77 0.03 0.05 0.08 0.10 0.14 0.17 0.21 0.26 0.31 0.42 0.54 0.69 0.85 1.03 1.23 1.44 25 8500 6.31 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.55 0.67 0.81 0.97 1.14 30 4000 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 30 5000 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 30 6000 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 30 7000 3.77 0.03 0.05 0.08 0.10 0.14 0.17 0.21 0.26 0.31 0.42 0.54 0.69 0.85 1.03 1.23 1.44 30 8500 6.31 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.55 0.67 0.81 0.97 1.14 30 10500 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 30 12500 6.31 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.55 0.67 0.81 0.97 1.14 CLCH-PRC022A-EN 173 Performance Data Table 156. Energy wheel bypass damper performance data Wheel Unit nominal size cfm Area (ft2) Unducted Pressure Drop 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 35 5000 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 35 6000 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 35 7000 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 35 8500 6.31 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.55 0.67 0.81 0.97 1.14 35 10500 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 35 12500 6.31 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.55 0.67 0.81 0.97 1.14 35 15000 7.28 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.20 0.24 0.32 0.42 0.53 0.65 0.79 0.94 1.10 35 17500 8.20 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.19 0.23 0.31 0.41 0.52 0.64 0.77 0.92 1.08 40 5000 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 40 6000 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 40 7000 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 40 8500 6.31 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.55 0.67 0.81 0.97 1.14 40 10500 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 40 12500 6.31 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.55 0.67 0.81 0.97 1.14 40 15000 7.28 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.20 0.24 0.32 0.42 0.53 0.65 0.79 0.94 1.10 40 17500 8.20 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.19 0.23 0.31 0.41 0.52 0.64 0.77 0.92 1.08 40 20000 9.90 0.02 0.04 0.06 0.08 0.10 0.13 0.16 0.19 0.22 0.30 0.40 0.50 0.62 0.75 0.90 1.05 50 7000 6.31 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.55 0.67 0.81 0.97 1.14 50 8500 6.31 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.55 0.67 0.81 0.97 1.14 50 10500 5.09 0.02 0.04 0.05 0.07 0.10 0.12 0.15 0.18 0.22 0.29 0.38 0.48 0.60 0.72 0.86 1.01 50 12500 6.31 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.55 0.67 0.81 0.97 1.14 50 15000 7.28 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.20 0.24 0.32 0.42 0.53 0.65 0.79 0.94 1.10 50 17500 8.20 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.19 0.23 0.31 0.41 0.52 0.64 0.77 0.92 1.08 50 20000 9.90 0.02 0.04 0.06 0.08 0.10 0.13 0.16 0.19 0.22 0.30 0.40 0.50 0.62 0.75 0.90 1.05 50 25000 10.96 0.02 0.04 0.06 0.08 0.10 0.12 0.15 0.19 0.22 0.30 0.39 0.50 0.61 0.74 0.88 1.04 Mixing Box Dampers Mixing box with airfoil blade dampers Table 157. Mixing box with front, back, top, and bottom airfoil blade dampers (unducted) Static Pressure Drop (inches wg) by Damper Face Velocity Unit Size Area (ft2) 400 500 600 700 800 900 3 1.29 0.05 0.07 0.11 0.14 0.19 0.24 0.29 0.36 0.42 0.58 0.75 0.95 1.17 1.42 1.69 1.99 4 1.87 0.04 0.06 0.09 0.13 0.16 0.21 0.26 0.31 0.37 0.50 0.66 0.83 1.03 1.25 1.48 1.74 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 6 2.45 0.04 0.06 0.09 0.12 0.15 0.20 0.24 0.29 0.35 0.47 0.62 0.78 0.96 1.17 1.39 1.63 8 3.33 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.33 0.45 0.58 0.74 0.91 1.11 1.32 1.54 10 4.16 0.04 0.06 0.08 0.11 0.14 0.18 0.22 0.27 0.32 0.43 0.57 0.72 0.89 1.07 1.28 1.50 12 5.10 0.03 0.05 0.08 0.11 0.14 0.18 0.22 0.26 0.31 0.43 0.56 0.70 0.87 1.05 1.25 1.47 14 5.66 0.03 0.05 0.07 0.10 0.12 0.16 0.19 0.24 0.28 0.38 0.50 0.63 0.78 0.94 1.12 1.31 17 6.99 0.03 0.05 0.07 0.09 0.12 0.15 0.19 0.23 0.27 0.37 0.49 0.62 0.76 0.92 1.09 1.28 174 CLCH-PRC022A-EN Performance Data Table 157. Mixing box with front, back, top, and bottom airfoil blade dampers (unducted) Static Pressure Drop (inches wg) by Damper Face Velocity Unit Size Area (ft2) 400 500 600 700 800 900 21 8.64 0.03 0.05 0.07 0.09 0.12 0.15 0.19 0.23 0.27 0.37 0.48 0.60 0.75 0.90 1.07 1.26 22 7.26 0.03 0.05 0.07 0.09 0.12 0.15 0.18 0.22 0.26 0.36 0.46 0.59 0.73 0.88 1.04 1.23 25 10.36 0.03 0.04 0.06 0.09 0.11 0.14 0.17 0.21 0.25 0.34 0.45 0.57 0.70 0.85 1.01 1.18 26 10.53 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.55 0.67 0.82 0.97 1.14 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 30 12.04 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.21 0.25 0.34 0.44 0.56 0.69 0.84 0.99 1.17 31 11.07 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.55 0.68 0.82 0.98 1.15 35 14.32 0.03 0.04 0.06 0.09 0.11 0.14 0.18 0.22 0.26 0.35 0.46 0.58 0.72 0.87 1.03 1.21 36 10.01 0.03 0.04 0.06 0.09 0.11 0.14 0.18 0.21 0.25 0.34 0.45 0.57 0.70 0.85 1.01 1.18 40 16.29 0.03 0.04 0.06 0.09 0.11 0.14 0.18 0.22 0.26 0.35 0.46 0.58 0.72 0.87 1.03 1.21 41 12.32 0.03 0.05 0.07 0.09 0.12 0.15 0.18 0.22 0.26 0.36 0.47 0.59 0.73 0.89 1.06 1.24 50 18.59 0.03 0.04 0.06 0.09 0.11 0.14 0.18 0.21 0.25 0.35 0.45 0.57 0.71 0.85 1.02 1.19 51 17.47 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.19 0.23 0.31 0.41 0.52 0.64 0.78 0.92 1.09 57 22.79 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.55 0.68 0.82 0.97 1.14 58 19.45 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.19 0.23 0.31 0.40 0.51 0.63 0.76 0.91 1.07 66 26.04 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.54 0.67 0.81 0.96 1.13 80 30.83 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.20 0.23 0.32 0.42 0.53 0.65 0.78 0.93 1.10 100 39.78 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.19 0.23 0.31 0.40 0.51 0.63 0.76 0.91 1.06 120 47.87 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.19 0.23 0.31 0.41 0.52 0.64 0.78 0.92 1.08 Table 158. Mixing box with front, back, top, and bottom airfoil blade dampers (ducted) Static Pressure Drop (inches w.g.) by Damper Face Velocity Unit Size Area (ft2) 400 500 600 700 800 900 3 1.29 0.07 0.10 0.15 0.20 0.26 0.33 0.41 0.49 0.59 0.80 1.04 1.32 1.63 1.98 2.35 2.76 4 1.87 0.05 0.07 0.11 0.15 0.19 0.24 0.30 0.36 0.43 0.59 0.77 0.97 1.20 1.45 1.72 2.02 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 6 2.45 0.04 0.06 0.09 0.12 0.16 0.20 0.25 0.30 0.36 0.49 0.64 0.81 1.00 1.21 1.44 1.69 8 3.33 0.03 0.05 0.08 0.10 0.14 0.17 0.21 0.26 0.31 0.42 0.55 0.69 0.86 1.04 1.23 1.45 10 4.16 0.03 0.05 0.07 0.10 0.12 0.16 0.19 0.24 0.28 0.38 0.50 0.63 0.78 0.94 1.12 1.32 12 5.10 0.03 0.05 0.07 0.09 0.12 0.15 0.18 0.22 0.26 0.36 0.46 0.59 0.73 0.88 1.04 1.23 14 5.66 0.02 0.03 0.05 0.06 0.08 0.10 0.13 0.16 0.19 0.25 0.33 0.42 0.52 0.62 0.74 0.87 17 6.99 0.02 0.03 0.04 0.06 0.08 0.10 0.12 0.14 0.17 0.23 0.30 0.38 0.47 0.57 0.68 0.79 21 8.64 0.02 0.03 0.04 0.05 0.07 0.09 0.11 0.13 0.16 0.21 0.28 0.35 0.43 0.53 0.63 0.73 22 7.26 0.02 0.02 0.04 0.05 0.06 0.08 0.10 0.12 0.14 0.19 0.25 0.32 0.40 0.48 0.57 0.67 25 10.36 0.01 0.02 0.03 0.04 0.05 0.07 0.08 0.10 0.12 0.16 0.21 0.27 0.33 0.40 0.48 0.56 26 10.53 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.09 0.10 0.14 0.18 0.23 0.29 0.35 0.41 0.48 30 12.04 0.01 0.02 0.03 0.04 0.05 0.06 0.08 0.10 0.11 0.15 0.20 0.26 0.32 0.38 0.45 0.53 31 11.07 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.09 0.11 0.14 0.19 0.24 0.29 0.35 0.42 0.49 35 14.32 0.01 0.02 0.03 0.04 0.05 0.07 0.08 0.10 0.12 0.16 0.21 0.26 0.33 0.39 0.47 0.55 36 10.01 0.01 0.02 0.03 0.04 0.05 0.07 0.08 0.10 0.12 0.17 0.22 0.27 0.34 0.41 0.49 0.57 40 16.29 0.01 0.02 0.03 0.04 0.05 0.07 0.08 0.10 0.12 0.16 0.21 0.27 0.33 0.40 0.48 0.56 41 12.32 0.01 0.02 0.03 0.04 0.06 0.07 0.09 0.11 0.13 0.18 0.23 0.29 0.36 0.43 0.52 0.61 50 18.59 0.01 0.02 0.03 0.04 0.05 0.06 0.08 0.10 0.11 0.16 0.20 0.26 0.32 0.38 0.46 0.54 51 17.47 0.01 0.01 0.02 0.03 0.04 0.04 0.05 0.07 0.08 0.11 0.14 0.18 0.22 0.27 0.32 0.37 57 22.79 0.01 0.02 0.02 0.03 0.04 0.05 0.06 0.08 0.09 0.13 0.16 0.21 0.26 0.31 0.37 0.43 58 19.45 0.01 0.01 0.02 0.02 0.03 0.04 0.05 0.06 0.07 0.10 0.13 0.16 0.20 0.24 0.28 0.33 CLCH-PRC022A-EN 175 Performance Data Table 158. Mixing box with front, back, top, and bottom airfoil blade dampers (ducted) Static Pressure Drop (inches w.g.) by Damper Face Velocity Unit Size Area (ft2) 400 500 600 700 800 900 66 26.04 0.01 0.02 0.02 0.03 0.04 0.05 0.06 0.07 0.09 0.12 0.16 0.20 0.24 0.29 0.35 0.41 80 30.83 0.01 0.01 0.02 0.03 0.03 0.04 0.05 0.06 0.07 0.10 0.13 0.17 0.21 0.25 0.30 0.35 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 100 39.78 0.01 0.01 0.02 0.02 0.03 0.04 0.04 0.05 0.06 0.09 0.11 0.14 0.17 0.21 0.25 0.30 120 47.87 0.01 0.01 0.02 0.02 0.03 0.04 0.05 0.06 0.07 0.09 0.12 0.15 0.18 0.22 0.26 0.31 Mixing box with Traq dampers Table 159. Mixing box with front/back/top standard and low-flow Traq dampers Unit Size Damper Damper Area Size (in) Quantity (sq ft) Traq Damper Velocity (fpm) vs. Delta P (w.g.) 800 900 1000 1100 1200 1300 1400 1500 3 13 1 0.92 0.06 0.07 0.09 0.11 0.13 0.15 0.17 0.20 1600 0.23 4 13 2 1.84 0.06 0.07 0.09 0.11 0.13 0.15 0.17 0.20 0.23 6 13 2 1.84 0.06 0.07 0.09 0.11 0.13 0.15 0.17 0.20 0.23 8 13 3 2.77 0.06 0.07 0.09 0.11 0.13 0.15 0.17 0.20 0.23 10 13 3 2.77 0.06 0.07 0.09 0.11 0.13 0.15 0.17 0.20 0.23 12 16 3 4.19 0.06 0.07 0.09 0.11 0.13 0.15 0.17 0.20 0.23 14 16 3 4.19 0.06 0.07 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.23 17 16 3 4.19 0.06 0.07 0.09 0.11 0.13 0.15 0.17 0.20 21 20 3 6.54 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 22 16 4 5.59 0.06 0.07 0.09 0.11 0.13 0.15 0.17 0.20 0.23 25 20 3 6.54 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 26 16 4 5.59 0.06 0.07 0.09 0.11 0.13 0.15 0.17 0.20 0.23 30 24 3 9.42 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 31 20 4 8.73 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 35 24 3 9.42 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 36 24 3 9.42 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 40 24 3 9.42 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 41 24 3 9.42 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 50 28 3 12.83 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 51 28 3 12.83 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 57 28 3 12.83 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 58 28 3 12.83 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 66 28 4 17.10 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 80 28 5 21.38 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 100 28 6 25.66 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 120 28 6 25.66 0.06 0.07 0.09 0.10 0.12 0.14 0.17 0.19 0.21 Notes: 176 1. Data a standard air density. 2. Traq damper airflow measurement station (AMS) ratings are based on AMCA Standard 610 Test Setup Figure 4 using differential pressure measurement with voltage signals from a Trane ventilation control module (VCM). 3. Performance of Traq dampers will be +/- 5 percent of data shown for AMCA 610 Test Setup Figure 4. 4. Sizes and shapes tested include 16-inch and 28-inch diameter circular. Rated sizes are from 13 inches to 24 inches diameter circular. 5. Low-flow Traq option includes one damper for minimum outside air and remaining dampers are for economizing. CLCH-PRC022A-EN Performance Data Table 160. Mixing box with front/back/top standard and low-flow Traq dampers Unit Size Traq Traq Damper Damper Damper Area Size (in) Quantity (sq ft) Traq Damper Velocity (fpm) vs. Delta P (w.g.) 1700 1800 1900 2000 2100 2200 2300 2400 3 13 1 0.92 0.26 0.29 0.32 0.35 0.39 0.43 0.47 0.51 2500 0.56 4 13 2 1.84 0.26 0.29 0.32 0.35 0.39 0.43 0.47 0.51 0.56 6 13 2 1.84 0.26 0.29 0.32 0.35 0.39 0.43 0.47 0.51 0.56 8 13 3 2.77 0.26 0.29 0.32 0.35 0.39 0.43 0.47 0.51 0.56 10 13 3 2.77 0.26 0.29 0.32 0.35 0.39 0.43 0.47 0.51 0.56 12 16 3 4.19 0.26 0.29 0.32 0.35 0.39 0.43 0.47 0.51 0.56 14 16 3 4.19 0.26 0.29 0.32 0.35 0.39 0.43 0.47 0.51 0.56 17 16 3 4.19 0.26 0.29 0.32 0.35 0.39 0.43 0.47 0.51 0.56 21 20 3 6.54 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 22 16 4 5.59 0.26 0.29 0.32 0.35 0.39 0.43 0.47 0.51 0.56 25 20 3 6.54 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 26 16 4 5.59 0.26 0.29 0.32 0.35 0.39 0.43 0.47 0.51 0.56 30 24 3 9.42 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 31 20 4 8.73 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 35 24 3 9.42 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 36 24 3 9.42 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 40 24 3 9.42 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 41 24 3 9.42 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 50 28 3 12.83 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 51 28 3 12.83 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 57 28 3 12.83 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 58 28 3 12.83 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 66 28 4 17.10 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 80 28 5 21.38 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 100 28 6 25.66 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 120 28 6 25.66 0.24 0.27 0.30 0.33 0.37 0.40 0.44 0.48 0.52 Notes: 1. Data a standard air density. 2. Traq damper airflow measurement station (AMS) ratings are based on AMCA Standard 610 Test Setup Figure 4 using differential pressure measurement with voltage signals from a Trane ventilation control module (VCM). 3. Performance of Traq dampers will be +/- 5 percent of data shown for AMCA 610 Test Setup Figure 4. 4. Sizes and shapes tested include 16-inch and 28-inch diameter circular. Rated sizes are from 13 inches to 24 inches diameter circular. 5. Low-flow Traq option includes one damper for minimum outside air and remaining dampers are for economizing. . Trane certifies that the Traq damper shown herein is licensed to bear the AMCA seal - Airflow Measurement Station Performance. The rating shown is based on tests and procedures performed in accordance with AMCA Publication 611 and complies with the requirements of the AMCA Certified Ratings Program. CLCH-PRC022A-EN 177 Performance Data AMCA 610 Test Performance for Traq Damper Table 161. Air Performance Test Run Reference Volume (cfm) 1 3470 2 Table 162. Airflow Resistance Indicated Volume (cfm) Difference (percent) Test Run Pressure Drop (in. w.g.) 3351 -3.41 1 0.561 3469.70 2882 2773 -3.80 2 0.389 2895.70 2074.30 3 2264 2211 -2.35 3 0.239 2276.30 1630.60 4 1703 1676 -1.62 4 0.135 1710.20 1225.10 5 1032 1019 -1.25 5 0.052 1035.00 741.40 6 506 505 -0.18 6 0.010 507.00 363.20 Traq 16-inch damper AMS Volume (cfm) Velocity (fpm) Traq 16-inch damper AMS Traq 28-inch damper AMS 2485.40 Traq 28-inch damper AMS 1 10714 10548 -1.55 1 0.515 10738.60 2 8817 8644 -1.96 2 0.352 8856.50 2511.40 2071.20 3 6997 6851 -2.09 3 0.228 7029.20 1643.90 4 5063 4961 -2.00 4 0.114 5085.50 1189.30 5 3126 3071 -1.76 5 0.041 3134.60 733.10 6 1363 1362 -0.06 6 0.010 1364.40 319.10 Corresponding conversion formulas: Traq 16-inch AMS: Airflow = ((Volts-2)/8)*2475*Total Area (applicable for unit sizes 3-17). Traq 28-inch AMS: Airflow = ((Volts-2)/8)*2600*Total Area (applicable for units sizes 21-30). Refer to the Performance Climate Changer air handler installation operation manual (CLCHSVX07A-EN) for Traq damper installation details. Multizone Dampers Table 163. Multizone damper - 2-deck with single actuator Static Pressure Drop (inches w.g.) by Damper Face Velocity (fpm) Unit size Area ft2 400 500 600 700 800 900 6 2.89 0.05 0.07 0.10 0.14 0.18 0.23 0.29 0.35 0.41 0.56 0.73 0.93 1.15 1.39 1.65 1.94 8 3.48 0.05 0.07 0.10 0.14 0.18 0.23 0.29 0.35 0.41 0.56 0.74 0.93 1.15 1.39 1.66 1.95 10 5.50 0.05 0.08 0.12 0.16 0.21 0.26 0.32 0.39 0.46 0.63 0.82 1.04 1.29 1.56 1.86 2.18 12 6.06 0.05 0.07 0.11 0.15 0.19 0.24 0.30 0.36 0.43 0.59 0.77 0.97 1.20 1.45 1.72 2.02 14 6.67 0.05 0.07 0.10 0.14 0.18 0.23 0.29 0.35 0.41 0.56 0.73 0.93 1.15 1.39 1.65 1.94 17 6.67 0.05 0.07 0.10 0.14 0.18 0.23 0.29 0.35 0.41 0.56 0.73 0.93 1.15 1.39 1.65 1.94 21 8.97 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.34 0.46 0.60 0.76 0.93 1.13 1.34 1.58 25 8.97 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.34 0.46 0.60 0.76 0.93 1.13 1.34 1.58 30 10.75 0.04 0.06 0.09 0.12 0.15 0.19 0.24 0.29 0.35 0.47 0.61 0.78 0.96 1.16 1.38 1.62 35 14.06 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.33 0.45 0.59 0.74 0.92 1.11 1.32 1.55 40 16.05 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.33 0.45 0.59 0.74 0.92 1.11 1.32 1.55 50 18.13 0.04 0.06 0.08 0.11 0.15 0.19 0.23 0.28 0.33 0.45 0.59 0.75 0.92 1.12 1.33 1.56 178 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 CLCH-PRC022A-EN Performance Data Table 164. Multizone damper - 3-deck with single actuator Static Pressure Drop (inches w.g.) by Damper Face Velocity (fpm) Unit size Area ft2 400 500 600 700 800 900 6 2.72 0.05 0.08 0.11 0.16 0.20 0.26 0.32 0.38 0.46 0.62 0.81 1.03 1.27 1.53 1.82 2.14 8 3.28 0.04 0.07 0.09 0.13 0.17 0.21 0.26 0.32 0.38 0.51 0.67 0.85 1.05 1.27 1.51 1.78 10 5.24 0.04 0.06 0.09 0.13 0.16 0.21 0.26 0.31 0.37 0.50 0.66 0.83 1.03 1.24 1.48 1.73 12 5.77 0.04 0.06 0.09 0.13 0.17 0.21 0.26 0.31 0.37 0.51 0.66 0.84 1.03 1.25 1.49 1.74 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 14 6.35 0.04 0.06 0.08 0.11 0.14 0.18 0.23 0.27 0.32 0.44 0.58 0.73 0.90 1.09 1.30 1.52 17 6.35 0.04 0.06 0.08 0.11 0.14 0.18 0.23 0.27 0.32 0.44 0.58 0.73 0.90 1.09 1.30 1.52 21 8.62 0.03 0.05 0.07 0.10 0.13 0.17 0.21 0.25 0.30 0.40 0.53 0.67 0.82 1.00 1.19 1.39 25 8.62 0.03 0.05 0.07 0.10 0.13 0.17 0.21 0.25 0.30 0.40 0.53 0.67 0.82 1.00 1.19 1.39 30 10.33 0.03 0.05 0.07 0.10 0.13 0.17 0.21 0.25 0.30 0.40 0.53 0.67 0.83 1.00 1.19 1.40 35 13.75 0.03 0.05 0.07 0.10 0.13 0.17 0.20 0.25 0.29 0.40 0.52 0.66 0.82 0.99 1.18 1.38 40 15.70 0.03 0.05 0.07 0.10 0.13 0.16 0.20 0.24 0.29 0.39 0.51 0.65 0.80 0.97 1.15 1.35 50 17.73 0.03 0.05 0.07 0.10 0.13 0.16 0.20 0.24 0.28 0.39 0.51 0.64 0.79 0.96 1.14 1.34 Table 165. Multizone damper - 3-deck with dual actuator Static Pressure Drop (inches w.g.) by Damper Face Velocity (fpm) Unit size Area ft2 400 500 600 700 800 900 6 2.72 0.03 0.05 0.07 0.10 0.13 0.16 0.20 0.25 0.29 0.40 0.52 0.66 0.81 0.99 1.17 1.38 8 3.28 0.03 0.05 0.07 0.10 0.13 0.17 0.20 0.25 0.29 0.40 0.52 0.66 0.82 0.99 1.18 1.38 10 5.24 0.03 0.05 0.07 0.09 0.12 0.15 0.19 0.23 0.27 0.37 0.48 0.61 0.75 0.91 1.08 1.27 12 5.77 0.03 0.05 0.06 0.09 0.12 0.15 0.18 0.22 0.26 0.35 0.46 0.58 0.72 0.87 1.04 1.22 14 6.35 0.03 0.04 0.06 0.09 0.11 0.14 0.18 0.21 0.25 0.35 0.45 0.57 0.71 0.86 1.02 1.20 17 6.35 0.03 0.04 0.06 0.09 0.11 0.14 0.18 0.21 0.25 0.35 0.45 0.57 0.71 0.86 1.02 1.20 21 8.62 0.03 0.05 0.07 0.09 0.12 0.15 0.19 0.23 0.27 0.36 0.48 0.60 0.74 0.90 1.07 1.26 25 8.62 0.03 0.05 0.07 0.09 0.12 0.15 0.19 0.23 0.27 0.36 0.48 0.60 0.74 0.90 1.07 1.26 30 10.33 0.03 0.05 0.07 0.09 0.12 0.16 0.19 0.23 0.28 0.38 0.49 0.62 0.77 0.93 1.10 1.29 35 13.75 0.03 0.05 0.07 0.09 0.12 0.15 0.19 0.23 0.27 0.37 0.49 0.62 0.76 0.92 1.10 1.29 40 15.70 0.03 0.05 0.07 0.09 0.12 0.15 0.19 0.23 0.27 0.37 0.49 0.62 0.76 0.92 1.10 1.29 50 17.73 0.03 0.05 0.07 0.09 0.12 0.16 0.19 0.23 0.28 0.38 0.49 0.62 0.77 0.93 1.11 1.30 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 Diffuser Table 166. Diffuser pressure drop Static Pressure Drop (inches wg) by Face Velocity (fpm) Unit Size 500 700 900 1100 1300 1500 1700 1900 2100 3-120 0.01 0.02 0.04 0.06 0.08 0.10 0.13 0.17 0.20 Table 167. Diffuser face area Unit Size 3 4 6 8 10 12 14 17 21 22 25 26 30 Area (ft2) 1.53 1.53 3.36 3.74 3.74 4.32 4.32 7.94 8.78 11.71 10.72 15.77 10.72 Unit Size 31 35 36 40 41 50 51 57 58 66 80 100 120 Area (ft2) 15.77 23.42 33.09 23.42 39.76 27.21 39.76 31.53 45.20 33.09 39.76 45.20 45.20 CLCH-PRC022A-EN 179 Performance Data Discharge Plenums Horizontal or Vertical Discharge Plenum with Factory Openings Figure 73. Horizontal plenum Figure 74. Vertical plenum Table 168. Discharge plenums - default factory outlet areas (ft2) Horizontal Plenum Rectangular Openings Vertical Plenum Round Openings Rectangular Openings Front/ Back Top Side Round Openings Front/ Back Top Side Unit Size Front Top Bottom Side Front Top Bottom Side 3 1.07 1.07 1.07 1.07 0.92 0.92 0.92 0.92 1.07 1.07 1.07 0.92 0.92 0.92 4 1.53 1.53 1.53 1.25 1.40 1.40 1.40 1.40 1.53 1.53 1.25 1.40 1.40 1.40 6 2.19 2.19 2.19 2.13 2.18 2.18 2.18 2.18 2.19 2.19 2.13 2.18 2.18 2.18 8 2.67 2.67 2.67 2.51 2.64 2.64 2.64 2.64 2.67 2.67 2.51 2.64 2.64 2.64 10 3.33 3.33 3.33 3.36 3.14 3.14 3.14 3.14 3.33 3.33 3.36 3.14 3.14 3.14 12 4.00 4.00 4.00 3.99 3.69 3.69 3.69 4.28 4.00 4.00 3.99 4.28 4.28 4.28 14 4.88 4.88 4.88 4.69 3.69 3.69 3.69 4.28 4.88 4.88 4.69 4.91 4.91 4.91 17 5.91 5.91 5.91 5.56 3.69 3.69 3.69 4.28 5.91 5.91 5.56 5.59 5.59 5.59 6.31 21 7.12 7.12 7.12 7.04 3.14 3.14 3.14 3.69 7.12 7.12 7.04 6.31 6.31 22 6.88 7.17 7.12 7.26 6.31 5.77 5.77 5.71 n/a n/a n/a n/a n/a n/a 25 8.54 8.54 8.54 8.13 7.07 7.07 7.07 7.88 8.54 8.54 8.13 7.88 7.88 7.88 26 11.39 8.54 8.54 8.13 7.88 7.47 6.49 11.17 n/a n/a n/a n/a n/a n/a 30 10.21 10.21 10.21 10.15 7.07 7.07 7.07 7.88 10.21 10.21 10.15 9.62 9.62 9.62 31 13.10 10.21 10.21 10.07 9.62 8.55 8.71 11.17 n/a n/a n/a n/a n/a n/a 35 13.56 13.09 11.67 11.25 11.54 11.17 11.17 5.52 13.56 13.09 11.25 11.54 11.17 11.54 36 14.93 11.25 11.67 11.25 15.9066 11.17 11.35 12.43 n/a n/a n/a n/a n/a n/a 40 14.89 14.70 13.42 12.67 12.57 12.61 12.61 5.52 14.89 14.70 12.67 12.57 12.61 12.57 41 17.36 13.75 11.67 13.33 15.90 11.17 11.35 14.53 n/a n/a n/a n/a n/a n/a 50 19.27 18.30 16.67 15.04 15.75 14.53 14.53 7.95 19.27 18.30 15.04 15.75 14.53 12.57 51 20.19 17.24 16.67 15.93 25.22 14.93 12.98 14.53 n/a n/a n/a n/a n/a n/a 57 21.88 20.63 18.89 17.94 18.34 16.76 16.76 11.17 n/a n/a n/a n/a n/a n/a 58 23.36 17.24 16.67 18.08 25.22 14.93 12.98 14.53 n/a n/a n/a n/a n/a n/a 66 25.36 23.61 20.40 19.23 21.12 18.92 18.92 12.43 n/a n/a n/a n/a n/a n/a 80 29.97 28.71 23.49 25.06 25.13 21.21 21.21 18.56 n/a n/a n/a n/a n/a n/a 100 37.28 34.53 30.04 32.29 31.50 26.84 26.84 24.35 n/a n/a n/a n/a n/a n/a 120 43.43 41.25 35.58 34.03 38.48 33.13 33.13 24.35 n/a n/a n/a n/a n/a n/a Note: 1. Openings can be varied in number, size, and location within the TOPSS Selection Software. 2. Sizes 35-120 have default multiple round openings as standard. 3. Bell mouth openings are available within the TOPSS Selection Software. 180 CLCH-PRC022A-EN Performance Data Formulas For all plenum openings, use: SP = OV F 2 OV P 2 K t ² --------------- + 0.5 ² --------------- 4005 4005 OVF = FM/OAF OVP = CFM/OAP OVF = fan outlet velocity OAF = fan outlet area (see “General Data,” p. 59) Where: SP = static pressure drop OVP = plenum opening outlet velocity Kt = value from Table 169 OAP = plenum opening area (see Table 168) Table 169. Discharge Plenums - Kt values for factory openings for plenum fans Unit size Discharge Location 3-120 Discharge Rectangular Radial 2.00 Rectangular Axial Discharge 2.50 Round Radial 2.00 Round Axial Discharge 2.50 Bell mouth Radial 1.60 Bell mouth Axial Discharge 1.80 Discharge Plenum Loss Housed Exhaust Fans Rectangular Discharge 0.50 Round Discharge 0.50 Exhaust Damper Section Discharge 0.45 Table 170. Discharge Plenums - Kt values for factory openings for housed fans Plenum location and Fan Discharge Size 3-8 FC 3-8 BC or AF 10-17 FC 10-17 AF Discharge Location Top Mounted Horizontally Mounted Horizontally Mounted Fan Top-front Fan Top-back Fan Front-top Fan Back-top Fan Front-bottom Fan Back-bottom Front-top 1.67 0.98 0.98 n/a 0.98 n/a Back-top 0.98 1.67 n/a 0.98 n/a 0.98 Top-front/back 0.98 0.98 1.67 1.67 0.98 0.98 Side-top 1.5 1.5 1.5 1.5 1.5 1.5 Bottom-front/back n/a n/a 0.98 0.98 1.67 1.67 Front-top 1.14 0.68 0.68 n/a 0.68 n/a Back-top 0.68 1.14 n/a 0.68 n/a 0.68 Top-front/back 0.68 0.68 1.33 1.33 0.78 0.78 Side-top 1.29 1.29 1.34 1.34 1.34 1.34 Bottom-front/back n/a n/a 0.78 0.78 1.33 1.33 Front-top 2.59 1.68 1.68 n/a 1.68 n/a Back-top 1.68 2.59 n/a 1.68 n/a 1.68 Top-front/back 1.68 1.68 2.59 2.59 1.68 1.68 Side-top 2.37 2.37 2.37 2.37 2.37 2.37 Bottom-front/back n/a n/a 1.68 1.68 2.59 2.59 Front-top 1.67 1.15 1.15 n/a 1.15 n/a Back-top 1.15 1.67 n/a 1.15 n/a 1.15 Top-front/back 1.15 1.15 1.83 1.83 1.23 1.23 Side-top 1.85 1.85 1.85 1.85 1.85 1.85 Bottom-front/back n/a n/a 1.23 1.23 1.83 1.83 CLCH-PRC022A-EN 181 Performance Data Table 170. Discharge Plenums - Kt values for factory openings for housed fans Plenum location and Fan Discharge Discharge Location Size Top Mounted Horizontally Mounted Horizontally Mounted Fan Top-front Fan Top-back Fan Front-top Fan Back-top Fan Front-bottom Fan Back-bottom Front-top 1.68 0.96 0.96 n/a 0.96 n/a Back-top 0.96 1.68 n/a 0.96 n/a 0.96 Top-front/back 0.96 0.96 1.68 1.68 0.96 0.96 Side-top 1.5 1.5 1.5 1.5 1.5 1.5 Bottom-front/back n/a n/a 0.96 0.96 1.68 1.68 Front-top 1.45 0.93 0.93 n/a 0.93 n/a Back-top 0.93 1.45 n/a 0.93 n/a 0.93 Top-front/back 0.93 0.93 1.81 1.81 1.13 1.13 Side-top 1.68 1.68 1.68 1.68 1.68 1.68 Bottom-front/back n/a n/a 1.13 1.13 1.81 1.81 21-31FC 21-58 AF Front-top 1.44 0.83 0.83 n/a 0.83 n/a Back-top 0.83 1.44 n/a 0.83 n/a 0.83 Top-front/back 0.83 0.83 1.44 1.44 0.83 0.83 Side-top 1.25 1.25 1.25 1.25 1.25 1.25 Bottom-front/back n/a n/a 0.83 0.83 1.44 1.44 Full bottom n/a n/a 0.73 0.73 0.73 0.73 Front-top n/a n/a 1.34 n/a 1.34 n/a Back-top n/a n/a n/a 1.34 n/a 1.34 Top-front/back n/a n/a 2.14 2.14 1.34 1.34 Side-top n/a n/a 2.11 2.11 2.11 2.11 Bottom-front/back n/a n/a 1.34 1.34 2.14 2.14 35-120 FC 66 -120 AF Economizer for Outdoor Units Table 171. Economizer - exhaust damper performance data Static Pressure Drop (inches w.g.) by Damper Face Velocity (fpm) Unit size Area (ft2) 400 500 600 700 800 900 3 1.09 0.05 0.08 0.11 0.16 0.20 0.26 0.32 0.38 0.46 0.62 0.81 1.03 1.27 1.54 1.83 2.15 4 1.09 0.05 0.08 0.11 0.16 0.20 0.26 0.32 0.38 0.46 0.62 0.81 1.03 1.27 1.54 1.83 2.15 6 1.53 0.04 0.07 0.10 0.13 0.18 0.22 0.27 0.33 0.40 0.54 0.70 0.89 1.10 1.33 1.58 1.85 8 1.97 0.04 0.06 0.09 0.12 0.16 0.21 0.25 0.31 0.37 0.50 0.65 0.82 1.02 1.23 1.46 1.72 10 2.29 0.04 0.06 0.09 0.13 0.16 0.21 0.26 0.31 0.37 0.50 0.65 0.83 1.02 1.24 1.47 1.72 12 3.05 0.04 0.06 0.09 0.12 0.15 0.19 0.24 0.29 0.34 0.47 0.61 0.77 0.96 1.16 1.38 1.62 14 3.19 0.03 0.05 0.08 0.10 0.14 0.17 0.21 0.26 0.31 0.42 0.55 0.69 0.86 1.04 1.23 1.45 17 4.18 0.03 0.05 0.07 0.10 0.13 0.16 0.20 0.25 0.29 0.40 0.52 0.66 0.81 0.98 1.17 1.37 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 21 5.04 0.03 0.05 0.07 0.10 0.13 0.16 0.20 0.24 0.28 0.39 0.51 0.64 0.79 0.96 1.14 1.33 25 6.27 0.03 0.05 0.07 0.09 0.12 0.16 0.19 0.23 0.28 0.38 0.49 0.62 0.77 0.93 1.11 1.30 30 6.65 0.03 0.05 0.07 0.09 0.12 0.15 0.19 0.23 0.27 0.37 0.49 0.62 0.76 0.92 1.10 1.29 35 8.06 0.03 0.04 0.06 0.09 0.11 0.15 0.18 0.22 0.26 0.35 0.46 0.58 0.72 0.87 1.03 1.21 40 9.42 0.03 0.04 0.06 0.09 0.11 0.15 0.18 0.22 0.26 0.35 0.46 0.58 0.72 0.87 1.03 1.21 50 12.32 0.03 0.05 0.07 0.09 0.12 0.15 0.18 0.22 0.26 0.36 0.47 0.59 0.73 0.89 1.06 1.24 57 14.27 0.03 0.04 0.06 0.09 0.11 0.14 0.18 0.22 0.26 0.35 0.46 0.58 0.72 0.87 1.03 1.21 182 CLCH-PRC022A-EN Performance Data Table 171. Economizer - exhaust damper performance data Static Pressure Drop (inches w.g.) by Damper Face Velocity (fpm) Unit size Area (ft2) 400 500 600 700 800 900 66 15.30 0.03 0.04 0.06 0.09 0.11 0.14 0.18 0.21 0.25 0.35 0.45 0.57 0.71 0.86 1.02 1.20 80 18.45 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.21 0.25 0.34 0.44 0.56 0.69 0.84 1.00 1.17 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 100 24.41 0.03 0.04 0.06 0.08 0.11 0.13 0.17 0.20 0.24 0.32 0.42 0.54 0.66 0.80 0.95 1.12 120 28.50 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.20 0.23 0.32 0.41 0.52 0.65 0.78 0.93 1.10 Table 172. Economizer - outside air/return damper Static Pressure Drop (inches w.g.) by Damper Face Velocity (fpm) Unit size Area (ft2) 400 500 600 700 800 900 3 1.22 0.05 0.08 0.11 0.15 0.19 0.24 0.30 0.36 0.43 0.59 0.77 0.98 1.21 1.46 1.74 2.04 4 1.89 0.04 0.06 0.09 0.12 0.16 0.20 0.25 0.31 0.36 0.49 0.65 0.82 1.01 1.22 1.45 1.71 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 6 2.57 0.04 0.06 0.08 0.11 0.14 0.18 0.23 0.27 0.33 0.44 0.58 0.73 0.91 1.10 1.30 1.53 8 3.33 0.03 0.05 0.08 0.10 0.14 0.17 0.21 0.26 0.31 0.42 0.54 0.69 0.85 1.03 1.22 1.43 10 4.16 0.03 0.05 0.07 0.10 0.13 0.16 0.20 0.24 0.29 0.39 0.51 0.64 0.80 0.96 1.15 1.35 12 5.14 0.03 0.05 0.07 0.09 0.12 0.15 0.19 0.23 0.27 0.37 0.49 0.62 0.76 0.92 1.10 1.29 14 5.64 0.03 0.04 0.06 0.09 0.11 0.14 0.18 0.21 0.25 0.35 0.45 0.57 0.71 0.86 1.02 1.20 17 6.94 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.21 0.25 0.33 0.44 0.55 0.68 0.82 0.98 1.15 21 8.68 0.03 0.04 0.06 0.09 0.11 0.14 0.17 0.21 0.25 0.34 0.45 0.56 0.70 0.84 1.00 1.18 25 10.42 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.21 0.25 0.33 0.44 0.55 0.68 0.83 0.98 1.15 30 12.08 0.03 0.04 0.06 0.08 0.11 0.13 0.17 0.20 0.24 0.33 0.42 0.54 0.66 0.80 0.96 1.12 35 14.25 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.20 0.23 0.32 0.41 0.52 0.65 0.78 0.93 1.10 40 16.17 0.03 0.04 0.06 0.08 0.10 0.13 0.16 0.19 0.23 0.31 0.41 0.52 0.64 0.77 0.92 1.08 50 19.45 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.21 0.25 0.34 0.44 0.55 0.68 0.83 0.99 1.16 57 22.73 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.20 0.24 0.33 0.43 0.54 0.67 0.81 0.96 1.13 66 27.27 0.03 0.05 0.07 0.09 0.12 0.15 0.19 0.23 0.27 0.37 0.48 0.61 0.75 0.90 1.08 1.26 80 32.57 0.03 0.05 0.07 0.09 0.12 0.15 0.18 0.22 0.26 0.36 0.47 0.59 0.73 0.88 1.05 1.23 100 41.34 0.03 0.04 0.06 0.08 0.11 0.14 0.17 0.21 0.25 0.33 0.44 0.55 0.68 0.83 0.98 1.15 120 48.82 0.03 0.04 0.06 0.08 0.11 0.13 0.17 0.20 0.24 0.32 0.42 0.54 0.66 0.80 0.95 1.12 Electric Heat Table 173. Electric heat pressure drop Static Pressure Drop (inches w.g.) by Face Velocity (fpm) Face Velocity 350 400 450 500 550 600 650 700 Pressure Drop 0.06 0.08 0.1 0.12 0.15 0.17 0.2 0.24 Table 174. Electric heat face area Unit Area Unit Area size (ft2) size (ft2) 3 4 6 8 10 12 14 17 21 22 25 26 2.18 3.79 4.73 6.43 8.52 10.54 11.70 14.58 17.57 17.48 21.13 21.60 CLCH-PRC022A-EN 30 31 35 36 40 41 50 51 57 58 66 25.52 26.72 30.97 32.29 34.98 37.81 45.17 45.56 52.25 51.73 62.65 183 Performance Data Filters Table 175.Maximum CFM for filters Unit Size Pleated Media 2-in. and 2-in. or 4-in. Flat 4-in. Angled Permanent 2-in. and 2-in. or 4-in. 4-in. Flat Angled Throwaway High Efficiency 2-in. and 2-in. or 4-in. Long 4-in. High 4-in. Flat Angled Cartridge/Bag HEPA Efficiency 625 625 800 800 500 500 625 600 625 3 2169 3475 2776 4448 1735 2780 2081 1200 2169 4 3475 5556 4448 7112 2780 4445 3475 1200 3475 6 4338 5556 5552 7112 3470 4445 4169 3600 4338 8 4581 6944 5864 8888 3665 5555 5000 4200 4581 10 6075 8681 7776 11,112 4860 6945 5419 5400 6075 12 8331 10,419 10,664 13,336 6665 8335 7706 6000 8331 14 9025 11,288 11,552 14,448 7220 9030 8400 6000 9025 17 11,806 18,056 15,112 23,112 9445 14,445 11,806 8400 11,806 21 13,456 20,831 17,224 26,664 10,765 16,665 13,750 12,600 13,456 22 13,194 20,831 16,888 26,664 10,555 16,665 10,831 11,400 13,194 25 16,944 31,250 21,688 40,000 13,555 25,000 16,250 14,400 16,944 26 18,231 27,775 23,336 35,552 14,585 22,220 16,250 16,200 18,231 30 19,025 35,419 24,352 45,336 15,220 28,335 17,638 16,800 19,025 31 22,138 36,113 28,336 46,224 17,710 28,890 21,250 18,000 22,138 35 23,263 39,581 29,776 50,664 18,610 31,665 21,669 18,000 23,263 36 25,000 39,063 32,000 50,000 20,000 31,250 22,500 21,600 25,000 40 25,519 43,750 32,664 56,000 20,415 35,000 22,500 22,200 25,519 41 30,138 41,669 38,576 53,336 24,110 33,335 30,000 27,000 30,138 50 34,375 62,500 44,000 80,000 27,500 50,000 31,250 27,600 34,375 51 34,306 59,025 43,912 75,552 27,445 47,220 35,000 28,800 34,306 57 39,581 62,500 50,664 80,000 31,665 50,000 37,500 34,200 39,581 58 38,194 61,806 48,888 79,112 30,555 49,445 38,750 33,600 38,194 66 47,225 70,831 60,448 90,664 37,780 56,665 41,669 39,600 47,225 80 53,475 94,444 68,448 120,888 42,780 75,555 55,000 45,600 53,475 100 65,106 104,169 83,336 133,336 52,085 83,335 70,831 61,200 65,106 120 76,388 121,525 97,776 155,552 61,110 97,220 83,750 71,400 76,388 Table 176.Filter area (ft.2) Unit Size 184 Side-load Side-load 2-in. and 4-in. Flat 2-in. and 4-in. Angled Side-load Bag/Cartridge Front-Load Bag/ Cartridge Filter Front-load HEPA 3 3.47 5.56 3.33 2.00 2.00 4 5.56 8.89 5.56 2.00 2.00 6 6.94 8.89 6.67 6.00 6.00 8 7.33 11.11 8.00 6.00 7.00 10 9.72 13.89 8.67 8.00 9.00 12 13.33 16.67 12.33 10.00 10.00 14 14.44 18.06 13.44 10.00 10.00 17 18.89 28.89 18.89 14.00 14.00 21 21.53 33.33 22.00 18.00 21.00 22 21.11 33.33 17.33 18.00 19.00 25 27.11 50.00 26.00 24.00 24.00 CLCH-PRC022A-EN Performance Data Table 176.Filter area (ft.2) Unit Size Side-load Side-load 2-in. and 4-in. Flat 2-in. and 4-in. Angled Side-load Bag/Cartridge Front-Load Bag/ Cartridge Filter Front-load HEPA 27.00 26 29.17 44.44 26.00 24.00 30 30.44 56.67 28.22 28.00 28.00 31 35.42 57.78 34.00 30.00 30.00 35 37.22 63.33 34.67 34.00 30.00 36 40.00 32.50 36.00 36.00 36.00 40 40.83 70.00 36.00 38.00 37.00 41 48.22 66.67 48.00 46.00 45.00 50 55.00 100.00 50.00 50.00 46.00 51 54.89 94.44 56.00 54.00 48.00 57 63.33 100.00 60.00 60.00 57.00 58 61.11 98.89 62.00 62.00 56.00 66 75.56 113.33 66.67 66.00 66.00 80 85.56 151.11 88.00 86.00 76.00 100 104.17 166.67 113.33 106.00 102.00 120 122.22 194.44 134.00 124.00 119.00 Table 177. Filters (clean) performance data Static Pressure Drop (inches wg) by Filter Face Velocity (fpm) Filter Type 200 250 300 350 400 450 500 550 600 2-inch permanent – MERV 2 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.09 0.11 2-inch disposable (TA) – MERV 5 0.04 0.06 0.08 0.10 0.13 0.15 0.18 n/a n/a 2-inch pleated media – MERV 8 0.08 0.11 0.14 0.18 0.22 0.26 0.30 0.34 0.39 2-inch pleated media – coated – MERV 7 0.08 0.11 0.14 0.18 0.21 0.26 0.30 0.35 0.40 4-inch pleated media – MERV 8 0.04 0.06 0.08 0.11 0.13 0.16 0.19 0.22 0.25 4-inch pleated media – coated – MERV 7 0.04 0.06 0.09 0.12 0.16 0.20 0.25 0.30 0.36 4-inch high efficient – 65% efficient – MERV 11 0.07 0.10 0.12 0.15 0.18 0.21 0.24 0.27 0.30 4-inch high efficient – 95% efficient – MERV 14 0.16 0.20 0.25 0.29 0.34 0.39 0.44 0.49 0.54 12-inch cartridge – 65% efficient – MERV 11 0.06 0.09 0.12 0.15 0.19 0.23 0.27 0.31 0.36 12-inch cartridge – 95% efficient – MERV 14 0.11 0.14 0.18 0.22 0.26 0.30 0.35 0.39 0.44 0.52 18-inch bag – 65% efficient – MERV 12 0.18 0.22 0.27 0.31 0.35 0.39 0.44 0.48 18-inch bag – 85% efficient – MERV 13 0.20 0.25 0.30 0.35 0.41 0.46 0.51 0.56 0.61 18-inch bag – 95% efficient – MERV 14 0.23 0.28 0.34 0.39 0.45 0.50 0.56 0.61 0.66 30-inch bag – 65% efficient – MERV 12 0.07 0.10 0.13 0.17 0.21 0.26 0.31 0.36 0.42 30-inch bag – 85% efficient – MERV 13 0.09 0.11 0.15 0.18 0.22 0.26 0.31 0.35 0.40 30-inch bag – 95% efficient – MERV 14 0.17 0.22 0.27 0.32 0.37 0.42 0.47 0.52 0.58 HEPA - 99.97% efficient - DOP 0.47 0.60 0.74 0.89 1.04 1.20 1.37 1.54 1.72 CLCH-PRC022A-EN 185 Performance Data Table 178. Filters (mid-life) performance data Static Pressure Drop (inches wg) by Filter Face Velocity (fpm) Filter Type 200 250 300 350 400 450 500 550 600 2-inch permanent – MERV 2 0.51 0.51 0.52 0.52 0.53 0.53 0.54 0.55 0.55 2-inch disposable (TA) – MERV 5 0.52 0.53 0.54 0.55 0.57 0.58 0.59 n/a n/a 2-inch pleated media – MERV 8 0.54 0.56 0.57 0.59 0.61 0.63 0.65 0.67 0.69 2-inch pleated media – coated – MERV 7 0.54 0.56 0.57 0.59 0.61 0.63 0.65 0.67 0.70 4-inch pleated media – MERV 8 0.52 0.53 0.54 0.56 0.57 0.58 0.59 0.61 0.62 4-inch pleated media – coated – MERV 7 0.52 0.53 0.55 0.57 0.59 0.61 0.63 0.65 0.67 4-inch high efficient – 65% efficient – MERV 11 0.64 0.65 0.66 0.68 0.69 0.70 0.72 0.73 0.75 4-inch high efficient – 95% efficient – MERV 14 0.68 0.70 0.72 0.75 0.77 0.79 0.82 0.84 0.87 12-inch cartridge – 65% efficient – MERV 11 0.63 0.65 0.66 0.68 0.70 0.72 0.74 0.76 0.78 12-inch cartridge – 95% efficient – MERV 14 0.65 0.67 0.69 0.71 0.73 0.75 0.77 0.80 0.82 18-inch bag – 65% efficient – MERV 12 0.69 0.71 0.73 0.75 0.77 0.80 0.82 0.84 0.86 18-inch bag – 85% efficient – MERV 13 0.70 0.73 0.75 0.78 0.80 0.83 0.85 0.88 0.90 18-inch bag – 95% efficient – MERV 14 0.71 0.74 0.77 0.80 0.82 0.85 0.88 0.90 0.93 30-inch bag – 65% efficient – MERV 12 0.63 0.65 0.67 0.69 0.71 0.73 0.76 0.78 0.80 30-inch bag – 85% efficient – MERV 13 0.64 0.66 0.68 0.70 0.71 0.73 0.76 0.78 0.80 30-inch bag – 95% efficient – MERV 14 0.69 0.71 0.73 0.76 0.78 0.81 0.83 0.86 0.89 HEPA - 99.97% efficient - DOP 1.23 1.30 1.37 1.44 1.52 1.60 1.68 1.77 1.86 Table 179. Filters (dirty) performance data Static Pressure Drop (inches wg) by Filter Face Velocity (fpm) Filter Type 200 250 300 350 400 450 500 550 600 2-inch permanent – MERV 2 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 2-inch disposable (TA) – MERV 5 1.00 1.00 1.00 1.00 1.00 1.00 1.00 n/a n/a 2-inch pleated media – MERV 8 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 2-inch pleated media – coated – MERV 7 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 4-inch pleated media – MERV 8 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 4-inch pleated media – coated – MERV 7 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 4-inch high efficient – 65% efficient – MERV 11 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 4-inch high efficient – 95% efficient – MERV 14 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 12-inch cartridge – 65% efficient – MERV 11 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 12-inch cartridge – 95% efficient – MERV 14 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 18-inch bag – 65% efficient – MERV 12 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 18-inch bag – 85% efficient – MERV 13 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 18-inch bag – 95% efficient – MERV 14 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 30-inch bag – 65% efficient – MERV 12 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 30-inch bag – 85% efficient – MERV 13 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 30-inch bag – 95% efficient – MERV 14 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 HEPA - 99.97% efficient - DOP 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 186 CLCH-PRC022A-EN Performance Data Gas Heat Table 180. Gas heat pressure drop Static Pressure Drop (inches w.g.) by Face Velocity (range = 750 - 2000) Unit Size Full Face Discharge Horizontal Discharge Vertical Discharge 6 0.32 0.42 0.65 8 0.38 0.48 0.78 10 0.42 0.52 0.85 12 0.46 0.56 0.88 14 0.49 0.59 0.89 17 0.51 0.61 0.90 21 0.53 0.63 0.94 25 0.55 0.65 1.00 30 0.60 0.70 0.99 35 0.42 0.52 0.84 40 0.47 0.57 0.91 50 0.49 0.59 0.91 57 0.58 0.68 1.02 66 0.52 0.62 0.91 80 0.54 0.64 0.99 100 0.62 0.72 1.10 120 0.54 0.64 1.00 Hoods Table 181. Exhaust hood performance data Static Pressure Drop (inches wg) by Face Velocity (fpm) Face Velocity (FPM) 700 800 900 1000 1100 1200 1300 1400 1500 1600 Pressure drop 0.03 0.04 0.05 0.06 0.07 0.09 0.10 0.12 0.13 0.15 Table 182. Exhaust hood face area Unit Size 3 4 6 8 10 12 14 17 21 25 30 35 40 50 57 Area (ft2) 1.25 1.25 1.49 1.78 2.00 2.52 3.21 3.17 4.07 4.36 5.28 7.69 7.94 8.67 9.23 Table 183. Inlet hood performance data Static Pressure Drop (inches wg) by Face Velocity (fpm) Face Velocity (FPM) 300 400 500 600 700 800 900 950 Pressure drop 0.04 0.06 0.10 0.15 0.20 0.26 0.33 0.37 CLCH-PRC022A-EN 187 Performance Data Each air handler has a rated nominal airflow (for example, 1500 cfm for a size 3). This nominal airflow is a quick guide to figure unit size requirements. Although this is the nominal airflow of a given unit, each unit is capable of producing more, until something limits the ability of the unit to meet this higher airflow requirement such as coil face velocity, filter face velocity, or the outside air inlet hood eliminator velocity. The eliminator in the inlet hood is rated to a maximum of 800 feet per minute. Above this limit, there is a high probability of bringing rain, water or snow into the unit, which could migrate to the conditioned space below. When selecting units for your application, remember not to undersize a unit to the point that the inlet hood eliminators can not handle the outside air cfm requirements. Table 184 shows the maximum airflow for inlet hoods. Table 184. Inlet hood airflow limitations (cfm) Mixing Section 1 Side hood 1 side inlet area (ft2) hood Unit size Back hood area (ft2) Back inlet hood 3 2.82 2257 2.23 4 6.96 5567 2.23 1781 6 7.52 6016 2.72 2179 1781 Economizer Section Inlet hood Single inlet area (ft2) hood 2 side hood area (ft2) 2 side inlet hoods 4.46 3563 1.88 1504 4.46 3563 3.65 2917 5.44 4358 4.53 3625 8 11.06 8847 3.29 2634 6.58 5268 5.79 4628 10 8.81 7050 3.81 3050 7.62 6100 6.57 5257 12 11.74 9393 4.80 3841 9.60 7681 7.74 6190 14 12.73 10,185 6.98 5582 13.96 11,163 10.31 8248 17 14.74 11,789 6.09 4870 12.18 9741 12.45 9960 21 18.39 14,716 8.15 6524 16.30 13,047 14.91 11,928 25 21.32 17,054 8.65 6917 17.30 13,834 17.48 13,984 30 28.37 22,694 9.68 7742 19.36 15,483 19.69 15,752 35 30.39 24,316 15.25 12,199 30.50 24,397 22.78 18,222 40 34.29 27,434 15.80 12,640 31.60 25,280 27.86 22,288 50 40.87 32,700 19.76 15,808 39.52 31,617 32.46 25,968 57 47.10 37,677 18.67 14,933 37.34 29,865 33.89 27,112 66 64.99 51,988 18.80 15,039 37.60 30,077 42.51 34,008 80 69.42 55,539 22.43 17,943 44.86 35,887 51.03 40,824 80 Traq n/a n/a 24.54 19,633 49.08 39,265 n/a n/a 100 81.29 65,029 29.05 23,239 58.10 46,477 63.15 50,520 100 Traq n/a n/a 51.83 41,463 103.66 82,926 n/a n/a 120 97.40 77,916 33.50 26,797 67.00 53,595 72.80 58,240 120 Traq n/a n/a 50.29 40,231 100.58 80,462 n/a n/a Humidifiers Table 185. Humidifier pressure drop Static Pressure Drop (inches w.g.) by Face Velocity (fpm) Face Velocity 400 450 500 550 600 650 700 750 800 850 900 Pressure drop 0.02 0.02 0.03 0.03 0.04 0.05 0.05 0.06 0.07 0.08 0.09 188 CLCH-PRC022A-EN Performance Data Table 186. Face area for building steam and atmospheric steam sources Building Steam Source CLCH-PRC022A-EN Atmospheric Steam Source Unit Size Area (ft.2) Unit Size Area (ft.2) 3 1.22 3 1.42 4 2.43 4 2.29 6 3.47 6 3.72 8 4.59 8 5.14 10 6.20 10 6.58 12 7.59 12 8.67 14 8.47 14 9.53 17 11.04 17 12.71 21 12.71 21 16.17 22 12.99 22 16.92 25 16.52 25 20.36 26 18.59 26 23.32 30 20.18 30 21.40 31 23.19 31 28.17 35 24.96 35 26.73 36 27.96 36 33.54 40 28.57 40 30.45 41 30.50 41 34.50 50 39.20 50 41.05 51 37.25 51 41.38 57 46.59 57 48.56 58 37.25 58 41.38 66 55.69 66 58.19 80 60.75 80 63.00 100 67.75 100 70.00 120 72.00 120 74.00 189 Performance Data Multizone Table 187. Baffle assembly pressure drop (inches w.g.) Baffle Assembly Pressure Drop (inches w.g.) Unit size Air flow (cfm) 70 60 6070 6060 40 4070 4060 4040 6 3000 0.10 0.19 0.29 0.38 0.67 0.77 0.86 1.33 8 4000 0.12 0.23 0.36 0.47 0.81 0.93 1.04 1.62 10 5000 0.07 0.14 0.21 0.27 0.47 0.54 0.61 0.94 12 6000 0.09 0.16 0.25 0.32 0.56 0.64 0.72 1.12 14 7000 0.10 0.18 0.28 0.36 0.62 0.72 0.80 1.25 17 8500 0.14 0.27 0.41 0.53 0.92 1.06 1.19 1.84 21 10,500 0.11 0.22 0.33 0.43 0.74 0.86 0.96 1.49 25 12,500 0.16 0.30 0.47 0.61 1.06 1.22 1.36 2.11 30 15,000 0.16 0.30 0.46 0.61 1.05 1.21 1.36 2.10 35 17,500 0.12 0.23 0.35 0.46 0.79 0.91 1.02 1.58 40 20,000 0.12 0.23 0.35 0.46 0.79 0.91 1.02 1.58 50 25,000 0.15 0.28 0.43 0.56 0.97 1.11 1.24 1.93 Silencers Table 188. Silencer performance data Pressure Drop (in. H2O) by Face Velocity (fpm) Length 3 ft. 5 ft. Model Unit Sizes 250 500 750 1000 1250 1500 RD-ULV-F2 10 0.03 0.11 0.26 0.45 0.70 1.01 1750 1.37 RD-ULV-F3 3, 21, 22, 25, 26, 40, 66, 80 0.03 0.11 0.25 0.45 0.70 1.00 1.36 RD-ULV-F4 41, 50, 57, 100, 120 0.03 0.11 0.25 0.44 0.68 0.98 1.32 RD-ULV-F5 8, 14, 17, 30, 35, 51, 58 0.03 0.12 0.27 0.47 0.73 1.05 1.43 RD-ULV-F6 4, 6,12, 31 0.03 0.12 0.28 0.50 0.78 1.13 1.54 RD-ULV-F7 36 0.03 0.13 0.29 0.53 0.83 1.20 1.65 RD-ULV-F2 10 0.04 0.15 0.34 0.61 0.94 1.36 1.84 RD-ULV-F3 3, 21, 22, 25, 26, 40, 66, 80 0.04 0.15 0.34 0.59 0.92 1.31 1.78 RD-ULV-F4 41, 50, 57, 100, 120 0.04 0.15 0.33 0.57 0.89 1.27 1.71 RD-ULV-F5 8, 14, 17, 30, 35, 51, 58 0.04 0.15 0.34 0.61 0.94 1.35 1.83 RD-ULV-F6 4, 6,12, 31 0.04 0.16 0.36 0.64 0.99 1.43 1.94 RD-ULV-F7 36 0.04 0.17 0.38 0.67 1.05 1.52 2.07 Table 189. Silencer face area Unit Size 3 4 6 8 10 12 14 17 21 22 25 26 30 Area (ft2) 4.30 6.25 7.99 10.09 12.48 15.19 16.53 20.07 24.41 24.26 29.03 31.55 34.18 Unit Size 31 35 36 40 41 50 51 57 58 66 80 100 120 Area (ft2) 37.31 40.50 43.54 45.77 51.46 58.43 60.60 66.66 68.21 78.20 92.42 114.70 135.66 190 CLCH-PRC022A-EN Performance Data Trane Catalytic Air Cleaning Systems (TCACS Table 190. TCACS pressure drop Static Pressure Drop (inches w.g.) by Face Velocity (fpm) Face Velocity 200 250 300 350 400 450 500 550 600 Pressure drop 0.010 0.014 0.017 0.022 0.026 0.030 0.035 0.040 0.045 Table 191. TCACS face area Unit Size 3 4 6 8 10 12 14 17 21 22 25 26 30 Area (ft2) 2.92 5.14 6.17 7.97 10.31 13.33 13.78 17.22 21.08 20.61 24.92 27.97 29.97 Unit Size 31 35 36 40 41 50 51 57 58 66 80 100 120 Area (ft2) 32.72 35.00 38.89 39.67 39.61 51.11 53.03 60.69 62.25 68.89 79.22 107.25 126.00 Electrical Data Table 192. Current requirements - full load amps VFD Starter HP 200 230 460 575 200 230 460 575 1 6.30 6.30 2.50 2.30 4.80 4.20 2.10 1.70 1.5 6.30 6.30 2.50 2.30 6.90 6.00 3.00 2.40 2 7.30 7.30 3.40 2.60 7.80 6.80 3.40 2.70 3 10.40 10.40 4.80 3.80 11.00 9.60 4.80 3.90 5 16.80 16.80 8.30 5.90 17.50 15.20 7.60 6.10 7.5 23.80 23.80 10.60 9.20 25.30 22.00 11.00 9.00 10 32.20 32.20 14.20 11.10 32.20 28.00 14.00 11.00 15 48.30 48.30 21.00 16.60 48.30 42.00 21.00 17.00 20 61.90 61.90 27.60 21.40 62.10 54.00 27.00 22.00 25 78.20 78.20 34.00 26.30 78.20 68.00 34.00 27.00 30 92.00 92.00 41.00 31.20 92.00 80.00 40.00 32.00 40 117.00 101.30 53.00 39.90 120.00 104.00 52.00 41.00 50 n/a 126.60 64.00 50.60 n/a 130.00 65.00 52.00 60 n/a n/a 77.00 60.40 n/a n/a 77.00 62.00 75 n/a n/a 104.00 75.00 n/a n/a 96.00 77.00 100 n/a n/a 128.00 92.40 n/a n/a 124.00 99.00 125 n/a n/a 157.00 n/a n/a n/a 156.00 n/a CLCH-PRC022A-EN 191 Mechanical Specifications Performance Climate ChangerTM air handlers must be rigged, lifted, and installed in strict accordance with the Installation, Operation, and Maintenance manual (CLCH-SVX07A-EN) for Performance air handlers. The units are also to be installed in strict accordance with the specifications. All units will be shipped with an integral base frame designed with the necessary number of lift points for safe installation. The lift points will be designed to accept standard rigging devices and be removable after installation. Units shipped in sections will have a minimum of four points of lift. Sizes 3-30 will also be shipped with a shipping skid designed for forklift transport. Units will be shipped with a shipping skid designed for forklift transport and the integral base will be designed with the necessary number of lift points for safe installation. The lift points will be designed to accept standard rigging devices and removable after installation. Units shipped in sections will have a minimum of four points of lift. Per ASHRAE 62.1 recommendation, units will be shipped stretch-wrapped to protect unit from intransit rain and debris. Installing contractor is responsible for long-term storage in accordance with the Installation, Operation, and Maintenance manual (CLCH-SVX07A-EN). Unit shall be UL and C-UL Listed. Air-handling performance data shall be certified in accordance with AHRI Standard 430. Unit sound performance data shall be provided using AHRI Standard 260 test methods and reported as sound power. Coil performance shall be certified in accordance with AHRI Standard 410. Seismic Certification Trane has qualified listed air-handling unit sizes 3-30 as certified for seismic applications in accordance with the following International Building Code (IBC) releases: IBC 2000, 2003, 2006, 2009. Seismic Qualification Testing and structural analysis shall be conducted in accordance with and strict adherence to the standards set forth within ASCE 7 by an independent approval agency with a complete list of certified models, options, and installation methods provided in an approved detailed report. The above referenced equipment shall be approved for seismic applications when properly installed and used as intended. The basis of the certification shall be obtained through a combination of testing of the active and energized components per AC156, and analysis of the main force resisting members of the unit. Additional calculations shall be conducted to ensure components, accessories, and options remained intact and attached to the unit under seismic load conditions. The certification shall be based on a maximum Design Structural Response Acceleration at Short Period (Sds) value of 1.85 g's for IBC 2006 and 2009, and 1.93 for IBC 2000 and 2003. This is obtained from the Maximum Considered Earthquake Short Period Spectral Response Acceleration, Ss, of 2.78 g's or 2.90 g's as determined by the ASCE 7 seismic maps for Soil Site Class B with 5 percent damping. When the site soil properties or final equipment installation location are not known, the soil site coefficient, Fa, defaults to the Soil Site Class D coefficient. Occupancy Category IV and Seismic Design Category C shall be covered under this certification, limited by the Sds value stated above. A seismic importance factor, Ip, of 1.5 shall apply to the certification to include essential facility requirements and life safety applications for post event functionality. IBC 2000, 2003 FP/WP = 0.4 x 2/3(Ss=2.90) x (FA=1) x (IP=1.5) x (aP/RP=0.40) x (1+2(z/h=1.0)) = 1.39 g's IBC 2006, 2009 FP/WP = 0.4 x 2/3(Ss=2.78) x (FA=1) x (IP=1.5) x (aP/RP=0.42) x (1+2(z/h=1.0)) = 1.39 g's Structural floors, housekeeping pads, supporting curbs, and supporting steel must be seismically designed and approved by the project or building Structural Engineer of Record to withstand the seismic anchor loads. Installation details such as special inspection, attachment to a curb, or attachment to a non-building structure must be outlined and approved by the Engineer of Record for the project or building. The installing contractor shall be responsible for the proper installation 192 CLCH-PRC022A-EN Mechanical Specifications of the equipment and must observe the seismic installation requirements set forth by the Engineer of Record. Unit Construction Casing Construction All unit panels shall be 2-inch solid, double-wall construction to facilitate cleaning of unit interior. Unit panels shall be provided with a mid-span, no through metal, internal thermal break. Casing thermal performance shall be such that under 55°F supply air temperature and design conditions on the exterior of the unit of 81°F dry bulb and 73°F wet bulb, condensation shall not form on the casing exterior. All exterior and interior AHU panels will be made of galvanized steel. Optionally, all interior AHU casing panels will be made of stainless steel. The casing shall be able to withstand up to 8 inches w.g. positive or negative static pressure. The casing shall not exceed 0.0042 inch deflection per inch of panel span at 1.5 times design static pressure up to a maximum of +8 inches w.g. in all positive pressure sections and -8 inches w.g. in all negative pressure sections. Unit Flooring The unit floor shall be of sufficient strength to support a 300-lb. load during maintenance activities and shall deflect no more than 0.0042 inch per inch of panel span. Casing Leakage The casing air leakage shall not exceed leak class 9 (CL = 9) per ASHRAE 111 at 1.25 times maximum casing static pressure (P in inches w.g.), up to a maximum of +8 inches w.g. in all positive pressure sections and -8 inches w.g. in all negative pressure sections, where maximum casing leakage (cfm/ 100 ft2 of casing surface area) = CL x P0.65. Optionally, the casing air leakage shall not exceed leak class 6 (CL = 6) per ASHRAE 111 at 1.25 times maximum casing static pressure (P in inches w.g.), up to a maximum of +8 inches w.g. in all positive pressure sections and -8 inches w.g. in all negative pressure sections, where maximum casing leakage (cfm/100 ft2 of casing surface area) = CL x P0.65. Insulation Panel insulation shall provide a minimum thermal resistance (R) value of 13 ft²•h•ºF/Btu throughout the entire unit. Insulation shall completely fill the panel cavities in all directions so that no voids exist and settling of insulation is prevented. Panel insulation shall comply with NFPA 90A. Drain Pans All cooling coil sections shall be provided with an insulated, double-wall, galvanized or stainless steel drain pan. To address indoor air quality (IAQ), the drain pan shall be designed in accordance with ASHRAE 62.1 being of sufficient size to collect all condensation produced from the coil and sloped in two planes promoting positive drainage to eliminate stagnant water conditions. The outlet shall be located at the lowest point of the pan and shall be sufficient diameter to preclude drain pan overflow under any normally expected operating condition. All drain pan threaded connections shall be visible external to the unit. Drain connections shall be of the same material as the primary drain pan and shall extend a minimum of 2 1/2 inches beyond the base to ensure adequate room for field piping of condensate drain traps. Coil support members inside the drain pan shall be of the same material as the drain pan and coil casing. Heating coil, access, and mixing sections may be provided with an optional IAQ drain pan. CLCH-PRC022A-EN 193 Mechanical Specifications Access Doors Access doors shall be 2-inch double-wall construction. Interior and exterior door panels shall be of the same construction as the interior and exterior wall panels, respectively. All doors downstream of cooling coils shall be provided with a thermal break construction of door panel and door frame. Gasketing shall be provided around the full perimeter of the doors to prevent air leakage. Surface-mounted handles shall be provided to allow quick access to the interior of the functional section and to prevent through-cabinet penetrations that could likely weaken the casing leakage and thermal performance. Handle hardware shall be designed to prevent unintended closure. Access doors shall be hinged and removable for quick, easy access. Hinges shall be interchangeable with the door handle hardware to allow for alternating door swing in the field to minimize access interference due to unforeseen job site obstructions. Door handle hardware shall be adjustable and visually indicate locking position of door latch external to the section. All doors shall be a minimum of 60 inches high when sufficient height is available, or the maximum height allowed by the unit height. Door handles will be provided for each latching point of the door necessary to maintain the specified air leakage integrity of the unit. Optionally, a single-handle door shall be provided for all outward swinging doors linked to multiple latching points necessary to maintain the specified air leakage integrity of the unit. View Windows An optional shatterproof window for viewing, capable of withstanding unit operating pressures, shall be provided in the door. Marine Lights A factory-mounted, weather-resistant (enclosed and gasketed to prevent water and dust intrusion), light emitting diode (LED) fixture shall be provided in sections of the unit as specified for maintenance and service visibility. Fixture shall be complete with aluminum die cast housing, polycarbonate lens designed for maximum light output, and LEDs wired to a single switch within a factory-provided service module. LED lighting shall provide instant-on white light and have a minimum 50,000 hour life. Fixtures shall be designed for flexible positioning during maintenance and service activities for optimal location. All lights within the unit shall be wired to a single switch within the factory provided service module. The service module shall include a GFCI receptacle separate from the load side of the equipment. Electrical contractor shall be required to provide a 120V supply to the factory-mounted service module for the marine light circuit (unless single-point power is provided) and always for the GFCI receptacle circuit per NEC. The service module shall be provided on the fan section, unless a controls section is provided. In which case, the service module will be provided on the controls section. Fans The fan type shall be provided as required for stable operation and optimum energy efficiency. The fan shall be statically and dynamically balanced at the factory as a complete fan assembly (fan wheel, motor, drive, and belts). The fan shaft shall not exceed 75 percent of its first critical speed at any cataloged speed. Fan wheels shall be keyed to the fan shaft to prevent slipping. The fan shafts shall be solid steel. The fan section shall be provided with an access door on the drive side of the fan. 194 CLCH-PRC022A-EN Mechanical Specifications FC Fan The fan shall be a double-width, double-inlet, multi-blade-type, forward-curved (FC) fan. The fan shall be equipped with self-aligning, antifriction bearings with an L-50 life of 200,000 hours as calculated per ANSI/AFBMA Standard 9. Fan performance shall be certified as complying with AHRI Standard 430. BC Fan The fan shall be a double-width, double-inlet, multi-blade-type backward-curved (BC) fan. The fan shall be equipped with self-aligning, antifriction bearings with an L-50 life of 200,000 hours as calculated per ANSI/AFBMA Standard 9. Fan performance shall be certified as complying with AHRI Standard 430. AF Fan The fan shall be a double-width, double-inlet, multi-blade-type, airfoil (AF) fan. The fan shall be equipped with self-aligning, antifriction bearings with an L-50 life of 200,000 hours, as calculated per ANSI/AFBMA Standard 9. Fan performance shall be certified as complying with AHRI Standard 430. Belt-Drive Plenum Fan The fan shall be a single-width, single-inlet, multi-blade-type, plenum fan. The fan blades shall be backward-inclined airfoil. Belt-drive plenum fans shall be equipped with self-aligning, antifriction, pillow-block bearings with an L-50 life of 200,000 hours as calculated per ANSI/AFBMA Standard 9. Direct-Drive Plenum Fan The fan shall be a single-width, single-inlet, 9-blade or 12-blade plenum fan. The fan blades shall be aluminum backward-inclined airfoil. Plenum fan shall be direct-driven. Fan sections containing multiple fans shall be controlled using a common control signal, such as the duct static control signal, to modulate the fan speed. Fan Isolation All fans, including direct-drive plenum fans, shall be mounted on isolation bases and isolated from the unit casing by a flexible connection. 1-Inch, Seismic Spring Isolators The fan and motor assembly (on sizes 3 to 8) shall be internally isolated from the unit casing with 1-inch (25.3-mm) deflection spring isolators, furnished and installed by the unit manufacturer. The isolation system shall be designed to resist loads produced by external forces, such as earthquakes, and conform to the current IBC seismic requirements. 2-Inch, Seismic Spring Isolators The fan and motor assembly (on sizes 10 to 120) shall be internally isolated from the unit casing with 2-inch (50.8-mm) deflection spring isolators, furnished and installed by the unit manufacturer. The isolation system shall be designed to resist loads produced by external forces, such as earthquakes, and conform to the current IBC seismic requirements. Fan Drives CLCH-PRC022A-EN • Variable Pitch. The drives shall be variable pitch, suitable for adjustment within five percent of the specified speed. • Fixed Pitch. The drives shall be constant speed with fixed-pitch sheaves. 195 Mechanical Specifications • 1.2 Service Factor. The drives shall be selected at a minimum 20 percent larger than the motor horsepower. • 1.5 Service Factor. The drives shall be selected at a minimum 50 percent larger than the motor horsepower. Fan Motors The motor shall be integrally mounted to an isolated fan assembly furnished by the unit manufacturer. The motor shall be mounted inside the unit casing on an adjustable base to permit adjustment of drive-belt tension. The motor shall meet or exceed all NEMA Standards Publication MG1 requirements and comply with NEMA premium efficiency levels when applicable. The motor shall have T-frame, squirrel cage with size, type, and electrical characteristics as shown on the equipment schedule. • Open Drip-Proof. The motor shall be open and drip-proof. • Totally Enclosed Fan-Cooled (TEFC). The motor shall be totally enclosed and fan-cooled. • 200 volt, 3-phase, 60 Hz • 230 volt, 3-phase, 60 Hz • 460 volt, 3-phase, 60 Hz • 575 volt, 3-phase, 60 Hz • 115 volt, single-phase, 60 Hz • 230 volt, single-phase, 60 Hz Motor Options Grease Lines Bearings are selectable with life-time lubrication or with relubrication required. For any bearing requiring relubrication, the grease line shall be extended to the fan-support bracket on the drive side of the fan. Fan Section Options Multiple Belt Drive The fan section with a belt-driven fan shall be provided with a multiple belt drive. External Motor Junction Box The fan section shall have motor leads extended to a factory-installed NEMA 4 external junction box to facilitate motor wiring and to maintain air leakage integrity of the casing. Motor wiring conduit The fan motor wiring shall be factory-wired to the unit-mounted starter/disconnect, variable frequency drive (VFD), or external motor junction box within flexible metal conduit of adequate length so that the fan vibration isolation will not be restricted. Flow Meter The fan shall have an airflow measurement system to measure fan airflow directly or to measure differential pressure that can be used to calculate fan airflow. The system shall predict airflow within +/-5 percent total accuracy (device and transmitter) when operating within the stable operating region of the fan curve. The submitted fan airflow performance and noise levels shall not be affected by the installation of the device. Any device that provides an obstruction to the fan inlet will not be accepted. 196 CLCH-PRC022A-EN Mechanical Specifications Belt Guard Fan sections with centrifugal housed fans shall be provided with a corrosion-proof, wire mesh belt guard to deter incidental contact with rotating sheaves and belts. Door Guard Fans sections with plenum fans shall be provided with an expanded-metal guard screen for the access door, mounted on the door opening, to deter unauthorized entry and incidental contact with rotating components. Fan Modulation Variable-Frequency Drives (VFDs) For variable-air-volume applications, airflow shall be modulated by a VFD that controls fan speed. Inverter Test Inverter test shall be performed to check vibration at unloaded conditions. Fan vibration levels shall be checked from 100 percent to 30 percent of required operating rpm. Coils Coils shall be manufactured by the supplier of the air handling unit and installed such that headers and return bends are enclosed by unit casing. Coils shall be removable by unbolting the wall panels in the coil section. Coil connections shall be clearly labeled on unit exterior. Fin surfaces shall be cleaned prior to installation in the unit to remove any oil or dirt that may have accumulated on the fin surfaces during manufacturing of the coil. Horizontal and Vertical Coil Sections The coil section shall be provided complete with coil and coil holding frame. Coil section side panels shall be easily removable to allow for removal and replacement of coils without impacting the structural integrity of the unit. The coils shall be installed such that headers and return bends are enclosed by unit casings. If two or more cooling coils are stacked in the unit, an intermediate drain pan shall be installed between each coil. Like the primary drain pan, the intermediate drain pan shall be designed being of sufficient size to collect all condensation produced from the coil and sloped to promote positive drainage to eliminate stagnant water conditions. The intermediate pan shall begin at the leading face of the water-producing device and be of sufficient length extending downstream to prevent condensate from passing through the air stream of the lower coil. Intermediate drain pan shall include downspouts to direct condensate to the primary drain pan. The outlet shall be located at the lowest point of the pan and shall be sufficient diameter to preclude drain pan overflow under any normally expected operating condition. Inspection Section The coil section shall include an inspection section complete with a double-wall, removable door downstream of the coil for inspection, cleaning, and maintenance. Interior and exterior door panels shall be of the same construction as the interior and exterior wall panels, respectively. All doors downstream of cooling coils shall be provided with a thermal break construction of door panel and door frame. Water Coils (UW, UU, W, 5W, 5A, WD, 5D, D1, D2, P, or TT) The coils shall have aluminum fins and seamless copper tubes. Copper fins may be applied to coils with 5/8-inch tubes. Fins shall have collars drawn, belled, and firmly bonded to tubes by mechanical expansion of the tubes. The coil casing may be galvanized or stainless steel. The coils shall be proof-tested to 300 psig and leak-tested under water to 200 psig. Coil performance data and coils CLCH-PRC022A-EN 197 Mechanical Specifications containing water or ethylene glycol shall be certified in accordance with AHRI Standard 410. Propylene glycol and calcium chloride, or mixtures thereof, are outside the scope of AHRI Standard 410 and, therefore, do not require AHRI 410 rating or certification. Headers are to be constructed of round copper pipe or cast iron. • Tubes shall be 1/2-inch OD, 0.016-inch copper. • Tubes shall be 1/2-inch OD, 0.025-inch copper. • Tubes shall be 5/8-inch OD, 0.020-inch copper. • Tubes shall be 5/8-inch OD, 0.024-inch copper. • Tubes shall be 5/8-inch OD, 0.035-inch copper. Hydronic coils may be supplied with factory installed drain and vent piping to unit casing exterior. Refrigerant Cooling Coils (UF, FD) The coils shall have aluminum fins and seamless copper tubes. The fins shall have collars drawn, belled, and firmly bonded to tubes by mechanical expansion of the tubes. The coil casing may be galvanized or stainless steel. Suction and liquid line connections shall extend to the unit exterior. The coils shall be proof-tested to 450 psig and leak-tested to 300 psig air pressure under water. After testing, the inside of the coils shall be dried, all connections shall be sealed, and the coil shall be shipped with a charge of dry nitrogen. Suction headers shall be constructed of copper tubing with connections penetrating unit casings to permit sweat connections to refrigerant lines. The coils shall have equalizing vertical distributors sized according to the capacities of the coils. Coil performance data shall be certified in accordance with AHRI Standard 410. • Tubes shall be 1/2-inch OD, 0.016-inch copper. • Tubes shall be 1/2-inch OD, 0.025-inch copper. Steam Heating Coil (NS) The coils shall have aluminum fins and seamless copper tubes. Copper fins may be applied to coils with 1-inch tubes. The fins shall have collars drawn, belled, and firmly bonded to tubes by mechanical expansion of the tubes. The coil casing may be galvanized or stainless steel. Nonfreeze, steam-distributing-type coils shall be provided. Steam coils shall be pitched in the unit for proper drainage of steam condensate from coils. The coils shall be proof-tested to 300 psig and leak-tested to 200 psig air pressure under water. Headers are to be constructed of cast iron. Inner tubes shall have orifices that ensure even steam distribution throughout the full length of the outer tube. Orifices shall be directed toward the return connections to ensure that the steam condensate is adequately removed from the coil. Coil performance data shall be certified in accordance with AHRI Standard 410. • Tube construction shall be a 11/16-inch OD, 0.031-inch copper inner tube with a 1-inch OD, 0.031 copper outer tube. • Tube construction shall be a 11/16-inch OD, 0.031-inch copper inner tube with a 1-inch OD, 0.049-inch red brass outer tube. Coil Coating The coil shall have a flexible epoxy polymer e-coat uniformly applied to all coil surface areas without material bridging between fins. Coating process shall ensure complete coil encapsulation and a uniform dry film thickness from 0.8 - 1.2 mil on all surface areas including fin edges. Superior hardness characteristics of 2H per ASTM D3363-92A and a cross-hatch adhesion of 4B-5B per ASTM B3359-93. Impact resistance shall be up to 160 in/lb. per ASTM D2794-93. Humidity and water immersion resistance shall be up to a minimum 1000 and 260 hours respectively (ASTM D2247-92 and ASTM D870-02). Corrosion durability shall be confirmed through testing to no less than 5,000 hours salt spray per ASTM B117-90 using scribed aluminum test coupons. 198 CLCH-PRC022A-EN Mechanical Specifications Electric Heat Coil Section A UL-recognized electric heater shall be factory-installed in the air handler. The heater shall be an open-coil configuration with Type A wire (80% nickel and 20% chromium) derated to a maximum watt density of 45 watts per square inch. Safeties shall include three-pole, disconnecting-type contactors, airflow switches, automatic-reset functional limits, automatic-reset high-temperature limits, and manual-reset high-temperature limits. The contactors for energizing the electric heater shall be magnetic contactors. Electric heaters above 48 amps shall be fused into circuits not to exceed 48 amps as required by UL and NEC. Kilowatt output shall be selected to the nearest 0.1 kW of scheduled kilowatt. Power options: • 208 V, 3 ph • 240 V, 3 ph • 480 V, 3 ph • 600 V, 3 ph Control options: • Basic External Relay Control – The electric heater shall use standard contactors with one side of the holding coil that may be connected to the thermostat or controller for staging purposes. • Step Controller (0-10 VDC) – The electric heater shall be factory-wired to an electronic step controller relay bank. This type of control may be connected to a 0-10VDC or 4-20mA signal from a standalone thermostat or building automation system, which is converted to stages of heat. • SSR-Full Modulating Control (0-10 VDC) – The electric heater shall be factory-wired to accommodate SSR-Full Modulating control. The SSR control can receive a 0-10VDC or 4-20mA signal from a standalone thermostat or building automation system providing full modulating control of the heater. • SSR-Vernier Proportional Control (0-10 VDC) – The electric heater shall be factory-wired to accommodate SSR-Vernier control. The SSR control can receive a 0-10VDC or 4-20mA signal from a standalone thermostat or building automation system providing full modulating control of the first increment of heat, which is rated at 200% of all other chosen heat increments. There are a minimum of 3 and a maximum of 6 increments of heat stages. These stage increments are turned on and off by a step controller. As each stage is required to fulfill the demand for heat, the SSR increment is used as fully modulating between stages. Integral Face-and-Bypass Coils A section consisting of a horizontal or vertical-tube, integral face-and-bypass coil shall be provided. The coils shall be installed such that the headers and return bends are enclosed by the unit casings. The coils shall be sized as required to meet the scheduled capacity using steam or hot water, as specified. The integral face-and-bypass coils shall consist of a built-in series of finned heating elements and bypasses with interlocked dampers. Coil performance shall be certified in accordance with ARI Standard 410. Integral face-and-bypass coils shall be provided with a factorymounted damper actuator when specified. CLCH-PRC022A-EN 199 Mechanical Specifications Dampers Barometric Relief Dampers The frame shall be 20 gage roll formed galvanized steel. Blades shall be 28 gage roll formed galvanized steel. Blade seals shall be extruded vinyl, mechanically attached to the blade edge. Damper sections up to 24 inches wide shall be galvanized steel single tie bar linkage. Damper sections larger than 24 inches wide shall be stainless steel double tie bar linkage. Damper sections up to 42 inches wide shall be Zytel® synthetic axle assembly mechanically locked onto the blade edge. Damper sections larger than 42 inches wide shall be stainless steel axle and blade bracket assembly. Damper Performance and Operating Conditions The operating temperature range is -40F to 200F. Manufacturer must be able to demonstrate structural capacity of damper to withstand maximum system air velocity of 3,000 fpm when fully open. Manufacturer must be able to demonstrate structural capacity of damper to withstand maximum system back pressure of 6 inches w.g. in the closed position. Pressure drop shall be maximum 0.1 inch w.g. at 1,000 fpm across a fully open 24 inch x 24 inch damper. Damper pressure drop ratings shall be in accordance with Air Movement and Control Association (AMCA) 500. Dimensions and Tolerances - In addition to the dimensions and tolerances shown on the applicable drawing, the following dimension tolerance criteria must be met: • Mounting flange slot tolerance: -0/+0.031 • All sheet metal brake angles: +/- 3 degrees • Overall frame size: +0/-0.125 • Mounting flange flatness: • Overall dimension 48 inches and under: 0.062:/ft • Over 48 inches: within 0.25 inch overall • Frame squareness*: +/- 0.125 inch diagonal corner to corner *Squareness is defined as the difference between two diagonal measurements. Packing and Shipping - Dampers shall be prepared for shipment in accordance with commercial practice to assure carrier acceptance and safe transportation to the point of delivery. Packaging shall conform to carrier rules and regulations applicable to the mode of transportation. Energy Recovery Wheel Section The air-handling unit shall have a total energy recovery wheel sized per the ventilation requirement of the unit. Mixed air units with economizing shall be constructed with internal bypass dampers such that the pressure drop across the wheel does not increase during economizing. Performance and Certification The energy recovery wheel shall be ARI 1060-certified. The air-handling unit nameplate shall bear the ARI 1060 certification label. The energy recovery cassette shall be an Underwriters Laboratories (UL) Recognized Component certified for mechanical, electrical, and fire safety in accordance with UL Standard 1812. The calculated total net effectiveness of the recovery device shall be not less than 70 percent when the specified ventilation flow rate equals the exhaust flow rate. Wheel Construction The energy recovery wheel cassette shall incorporate a rotary wheel with all necessary seals, drive motor, and drive belts. The total energy recovery wheel shall incorporate a desiccant without the use of binders or adhesives. Coated segments shall be washable using standard detergent or alkaline-based coil cleaners. The desiccant shall not dissolve in the presence of water or high 200 CLCH-PRC022A-EN Mechanical Specifications humidity. The rim shall be of continuous rolled stainless steel and forms an even concentric circle, preventing leakage around the rim and minimizing the wear of components. All diameter and perimeter seals shall be provided as part of the cassette assembly. Perimeter seals shall be selfadjusting; diameter seals are adjustable. Seals shall be factory set. Wheel bearings shall be permanently sealed and lubricated and have a minimum L-10 life of 400,000 hours. Wheel Motor The wheel drive motor shall be mounted in the cassette frame. The wheel drive motor shall be thermally protected and UL Component Recognized. Drive belts shall not require belt tensioners. Maintenance and Access Energy recovery wheel shall be provided in the form of removable segments. The segments shall be removable without the use of tools to facilitate maintenance and cleaning as required. The cassette shall be removable through the energy recovery section side panel. Access doors shall be provided immediately upstream and downstream of the energy recovery wheel cassette. Adequate space shall be provided for cleaning, service, and maintenance of the wheel, motor, bearing, and belt. Wheel Control The energy recovery wheel section shall incorporate a variable effectiveness damper to control the energy wheel recovery capacity. The variable effectiveness control shall have the ability to modulate the total energy recovery effectiveness to 40 percent of the initial total recovery capacity. Variable frequency speed control is not an acceptable method for controlling capacity. Frost Control Frost control prevention shall be achieved by either outside air bypass, or return air preheat. Frost setpoint temperatures based on scheduled design air conditions shall be provided by the air handling manufacturer. Winter design supply and exhaust air conditions leaving the energy wheel provided by the unit manufacturer shall include any derate in performance due to frost protection measures. Wheel Warranty In conjunction with the air handler manufacturer ‘s standard unit warranty, the energy recovery wheel shall be warranted for a period of five years. Warranty applies to all parts and components of the energy recovery cassette with the exception of the motor. Cool Dry Quiet (CDQ™) Desiccant Wheel The air handling unit shall be provided with a CDQ desiccant wheel to control space humidity based on specified requirements. The wheel media shall meet the flammability requirements governing this class of products and shall be a UL-recognized component in accordance with UL 1812 and UL1995. Wheel Construction The CDQ desiccant wheel shall be constructed of a synthetic matrix with a type III desiccant. The wheel shall be structurally reinforced with a spoke system to minimize wheel deflection. All diameter and perimeter seals shall be provided as part of the cassette assembly. The drive system shall consist of a heavy-duty fractional horsepower A/C gear motor mounted in the cassette. CDQ Wheel Drive System The motor shall have permanently lubricated bearings. The bearings, which support rotation of the wheel around a center shaft, shall be provided with grease fittings for periodic lubrication. CLCH-PRC022A-EN 201 Mechanical Specifications Maintenance and Access Doors The wheel matrix shall be cleanable. The desiccant shall not dissolve in the presence of water or high humidity. Access doors shall be provided immediately upstream and downstream of the CDQ wheel cassette. Adequate space shall be provided for cleaning, service, and maintenance of the wheel, motor, bearing, and belt. Humidifiers Direct Steam Humidifier section shall be provided with a humidifier panel designed for building steam. Humidifier panel shall include stainless steel construction of all wetted parts including the header/ separator and multiple tube dispersion assembly. Tube-to-header joints shall consist of welded stainless steel. Humidifier shall provide a uniform steam discharge. Humidifiers shall be provided with a steam separator, control valve, inverted bucket steam trap, wye strainer, and two float and thermostatic steam traps shipped loose for field installation. All pipe connections shall be made from one side of the air handler. Atmospheric steam Humidifier section shall be provided with a humidifier panel designed for atmospheric steam. Humidifier panel shall include stainless steel construction of all wetted parts including the header/ separator and multiple tube dispersion assembly. Tube-to-header joints shall consist of welded stainless steel. Humidifier shall provide a uniform steam discharge. All pipe connections shall be made from one side of the air handler. Filters and Air Cleaners Filter sections shall have filter racks, at least one access door for filter removal, and filter block-offs to prevent air bypass around filters. The filter sections shall be supplied with 2-inch or 4-inch flat, or 2-inch or 4-inch angled, bag, or cartridge filters. Permanent Filters The filters shall be 2-inch, all-metal, viscous-imprisonment type, capable of operating up to 625-fpm face velocity without loss of filter efficiency and holding capacity. The filter media shall be layers of cleanable wire mesh. The filter frame shall be constructed of galvanized steel. The filters shall have a MERV 2 rating when tested in accordance with the ANSI/ASHRAE Standard 52.2. Throwaway Filters The filters shall be throwaway-type and shall have 2-inch fiberglass media contained in a rigid frame. Filters shall be capable of operating up to 500-fpm face velocity without loss of filter efficiency and holding capacity. Filters shall have a rigid supporting mesh across the leaving face of the media. The filters shall have a MERV 5 rating when tested in accordance with the ANSI/ ASHRAE Standard 52.2. Pleated Media Filters The filters shall be 2-inch or 4 inch, made with 100 percent synthetic fibers that are continuously laminated to a supported steel-wire grid with water repellent adhesive. Filters shall be capable of operating up to 625-fpm face velocity without loss of filter efficiency and holding capacity. The filters shall have a MERV 8 rating when tested in accordance with the ANSI/ASHRAE Standard 52.2. Bag Filters The filters shall be fine-fiber, all-glass media with spun backing to keep glass fibers from eroding downstream. The stitching method shall permit the bag to retain its pleated shape without the use 202 CLCH-PRC022A-EN Mechanical Specifications of a wire-basket support. The filters shall be capable of operating up to 625-fpm face velocity without loss of filter efficiency and holding capacity. The filters shall be sealed into a metal header. A gasket material shall be installed on the metal header of the filter to prevent filter bypass where the metal headers meet the side-access racks. All bag filters shall be furnished with a 2-inch pleated media MERV 8 prefilter to extend bag filter life. The manufacturer shall supply a side-access filter rack capable of holding bag filters and prefilters. The filters shall have a MERV 12 to 14 rating when tested in accordance with the ANSI/ASHRAE Standard 52.2. Cartridge Filters The filters shall be constructed with a continuous sheet of fine-fiber media made into closely spaced pleats. The filters shall be capable of operating up to 625-fpm face velocity for 12-inch deep filters without loss of filter efficiency and holding capacity. The filters shall be sealed into a metal frame assembled in a rigid manner. A gasket material shall be installed on the metal header of the filter to prevent filter bypass where the metal headers meet on the side-access racks. All cartridge filters shall be furnished with a 2-inch pleated media MERV 8 prefilter to provide extended cartridge life. The manufacturer shall supply a side-access filter rack capable of holding cartridge filters and prefilters. Cartridge filters shall have a MERV 11 to 15 rating when tested in accordance with the ANSI/ASHRAE Standard 52.2. 4-Inch High-Efficiency Filters The filters shall be constructed with a fine fiber media made into closely spaced pleats. The filters shall be capable of operating up to 625-fpm face velocity without loss of filter efficiency and holding capacity. The filter media shall be sealed into a frame assembled in a rigid manner. All 4-inch highefficiency filters shall be furnished with a 2-inch prefilter to provide extended filter life. The manufacturer shall supply a side-access filter rack capable of holding 4-inch high-efficiency filters and prefilters. The filters shall have a MERV 11 to 14 rating when tested in accordance with the ANSI/ASHRAE Standard 52.2. HEPA Filters The HEPA filter cells shall be enclosed in a galvanized steel frame with neoprene rubber applied to the leaving-air side of the filter cell to reduce air leakage. Continuously welded, front-load filter frames with filter holding clips shall be mounted inside the section casing and shall be gasketed to prevent leakage or air bypass. Filter clips shall require tooling in order to tighten and hold filter cells to frame. Filter media shall be produced from glass waterproof microfiber with a continuous pleat and aluminum separates between pleat folds. Filters shall be capable of operating up to 500fpm face velocity without loss of filter efficiency and holding capacity. HEPA filter efficiency shall be not less than 99.97 percent when tested in accordance with ASHRAE 52.1 atmospheric dust spot method. Although not covered by MERV ratings, HEPA filters shall be not less than an equivalent 17 when tested in accordance with ASHRAE 52.2. Ultraviolet (UVc) Lights UV-C light fixtures and lamps shall be provided by the air handler manufacturer. The UV-C fixtures shall be factory-assembled and tested in the air handler. Lamp life shall be 9,000 hours minimum with no more than a 20% loss of output after two years of continuous use. The UV-C fixtures and lamps shall be coupled end-to-end and mounted on a slide-out rack to enable complete replacement and/or maintenance of the bulbs from the unit exterior. Fixtures shall meet the UL drip-proof design criteria. Fixtures shall be constructed of stainless steel to resist corrosion. Fixtures shall have been tested and recognized by UL/C-UL under Category Code ABQK (Accessories, Air Duct Mounted), UL Standards 153, 1598 & 1995. CLCH-PRC022A-EN 203 Mechanical Specifications All polymeric materials that come into direct or indirect (reflected) contact with UV-C light shall be UV-C resistant or shielded from the UV-C light using a certified UV-C tolerant material such as metal. Access doors shall be provided at the location of each UV-C light as indicated on the plans and schedule. A view port with cover shall be provided to allow viewing of the UV-C light array to confirm operation. The view port and other AHU windows shall be treated to assure the UV-C energy emitted through it is below the threshold limits specified by NIOSH and ACGIH. All sections of the handler with access doors where the UV-C lights may pose a risk for direct exposure shall have a mechanical interlock switch that disconnects power to the lights when the door is opened. Each UV section shall also be equipped with an externally mounted on-off/ disconnect/shut off switch that disconnects power to the UV-C lights. The switch shall be equipped with a lock-out/tag-out to prevent unwanted operation of the UV-C lights. Air Cleaning Systems The Trane Catalytic Air Cleaner System (TCACS) shall be factory-engineered and factory-installed as a three-part integral assembly for treatment of air by: 1. High Efficiency Particle Filtration 2. Ultraviolet Germicidal Irradiation (UVGI) using UV-C lamps and fixtures 3. Photocatalytic Oxidation (PCO) catalyst media using titanium dioxide (TiO2) High efficiency particle filters shall be rated MERV 13 or higher. Filters are positioned upstream of the PCO media. UV-C lamps and ballasts designed specifically to provide type-C ultraviolet light with a wavelength at or near 253.7 Angstroms and shall not produce any ozone. Lamps shall be imbedded in the center of the catalyst media bank, spaced no further than six inches apart, and shall achieve a minimum coverage of five milliwatts per square inch of UVC light across all exposed surfaces of the PCO media. The catalyst media shall consist of six-inch deep (direction of airflow) grid with face area to match casing opening, one pleat per inch (nominal), and coated with 40-200 nanometer TiO2. The complete PCO media bank assembly shall be housed in a galvanized or stainless steel casing and placed in the air handler perpendicular to the airflow. All UV lamps and PCO media shall be removable from outside the AHU casing through a side access door for maintenance purposes. An air flow switch shall be wired into the control circuit to disable the UV lights when the AHU fan is not running. Power options: • 120V/1 phase/60 hz • 200-208V/3ph/60hz • 230V/3ph/60hz • 460V/3ph/60hz • 575V/3ph/60hz All 120V/1ph./60hz systems shall have an independent single point external power connection. Three phase systems shall be either independent single point power or integral with the AHU main power as shown on the drawings. All necessary main fusing shall be included. Electrical fixtures shall meet the UL drip proof design criteria. Component enclosures shall be constructed of galvanized steel or stainless steel to resist corrosion. Fixtures shall have been tested and recognized by UL/C-UL under Category Code ABQK (Accessories, Air Duct Mounted), UL Standards 1995. For Line Voltage options, the TCACS shall be provided with a UL 508 listed panel for power distribution and over-current protection. TCACS assemble shall be capable of withstanding 750 fpm face velocity with no structural damage All polymeric materials that come into direct or indirect (reflected) contact with UV-C light shall be tested and certified as UV-C tolerant. Any non-conforming construction materials or components within the exposure zone shall be completely shielded from the UV-C light using a certified UV-C 204 CLCH-PRC022A-EN Mechanical Specifications tolerant material. UV-C tolerance is defined as being capable of performing its intended duty for a minimum of 20 years. Access doors or panels shall be provided at the location of each Trane Catalytic Air Cleaner System as indicated on the plans and schedule. All access doors/panels shall have a mechanical safety interlock switch that disconnects the TCACS power upon opening. Each TCACS shall be equipped with an externally mounted electrical disconnect switch, with lock-out capability to prevent unwanted operation for maintenance purposes. A window shall be provided on each air handler to allow visual inspection of the Trane Catalytic Air Cleaner System during operation. The viewing window shall be guaranteed to block UV-C light emissions below the threshold limits specified by NIOSH and/or ACGIH. Units shall have a safety warning label applied to the exterior of each section containing UV-C lights. Complete safety, maintenance and servicing instructions for the Trane Catalytic Air Cleaner System shall be incorporated into the air handler manufacturer’s standard installation, operating and maintenance manuals. Filter Section Options Differential Pressure Gage A factory-installed dial type differential pressure gage shall be piped to both sides of the filter to indicate status. Gage shall maintain a +/- 5 percent accuracy within operating temperature limits of -20°F to 120°F. Gage shall be flush mounted with casing outer wall. Filter sections consisting of pre- and post-filters shall have a gage for each. Mixing Section Mixing Section, Filter Mixing Section, Airflow Measurement Station (Traq™ Dampers), and Economizer Sections A functional section shall be provided to support the damper assembly for outdoor, return, and/ or exhaust air. Dampers Dampers shall modulate the volume of outdoor, return, or exhaust air. The dampers shall be of double-skin airfoil design with metal, compressible jamb seals and extruded-vinyl blade-edge seals on all blades. The blades shall rotate on stainless-steel sleeve bearings. The dampers shall be rated for a maximum leakage rate of 3 cfm/ft² at 1 in. w.g. complying with ASHRAE 90.1 maximum damper leakage. All leakage testing and pressure ratings shall be based on AMCA Standard 500-D. Dampers may be arranged in a parallel or opposed-blade configuration. Airflow Measurement Station (Traq Dampers) A factory-mounted airflow measurement station tested in accordance with AMCA Standard 611 and bearing the AMCA Ratings Seal for Airflow Measurement Performance shall be provided in the outdoor and/or return air opening to measure airflow. The damper blades shall be galvanized steel, housed in a galvanized steel frame and mechanically fastened to a rotating axle rod. The dampers shall be rated for a maximum leakage rate of 4 cfm/ft² at 1 in. w.g. complying with ASHRAE 90.1 maximum damper leakage. The standard Traq airflow measurement station shall be capable of measuring from 15 percent to 100 percent of unit nominal airflow. Optionally, a low-flow Traq airflow measurement station shall be capable of measuring from 7.5 percent to 100 percent (sizes 6-30) of unit nominal airflow. The airflow measurement station shall adjust for temperature variations and provide a 2 to 10 Vdc signal that corresponds to actual airflow for controlling and documenting airflow. The accuracy of the airflow measurement station shall be ±5 percent. CLCH-PRC022A-EN 205 Mechanical Specifications Internal and External Face-and-Bypass Damper Section Dampers shall be provided as scheduled to divert airflow around the coil. Dampers shall be of double-skin airfoil design with metal, compressible jamb seals and extruded-vinyl blade-edge seals on all blades. The blades shall rotate on stainless-steel sleeve bearings. Dampers are arranged in an opposed-blade configuration and mechanically linked with jackshafts. The dampers shall be rated for a maximum leakage rate of 5 cfm/ft² at 1 in. w.g. All leakage testing and pressure ratings shall be based on AMCA Standard 500-D. Internal Face Damper Section Dampers shall be provided as scheduled within the air handler. Dampers shall be of double-skin airfoil design with metal, compressible jamb seals and extruded-vinyl blade-edge seals on all blades. The blades shall rotate on stainless-steel sleeve bearings. Dampers are arranged in an opposed-blade configuration and mechanically linked with jackshafts. The dampers shall be rated for a maximum leakage rate of 5 cfm/ft² at 1 in. w.g. All leakage testing and pressure ratings shall be based on AMCA Standard 500-D. Gas Heat Section Indirect-fired gas heaters shall be completely factory assembled, piped, and operationally fire tested at the factory prior to shipment. The heat exchanger primary drum and secondary tubes shall constructed from 14-gauge, 409 stainless steel. The industrial/commercial burner shall be UL listed, forced draft, and fully modulating. The control panel shall be equipped with Honeywell® RM7800 flame management controls and appropriate safeties. The gas heat section construction shall match the rest of the air handling unit and be an integral part of the unit. All burner and control components shall be housed in a burner vestibule with a large access door. The entire section shall bear a UL or CUL label for Commercial-Industrial Gas Heating Equipment (ANSI / UL Standard 795) and Industrial Gas-Fired Package Furnaces (CGA Standard 3.2-1976). Air-to-Air Plate Frame Heat Exchanger Construction Air-to-air, fixed-plate heat exchangers shall be provided as indicated on the schedule and drawings. Exchangers shall be a cross flow, plate-type with no moving parts or secondary heat transfer surfaces. Plates shall be a minimum 99.5% aluminum and formed with a plate profile for maximum efficiency and cleanability, and minimizes pressure loss. The connecting plate edges shall be double-folded and internally sealed with a silicone free elastic resin to minimize leakage. The corners of assembled exchanger packages shall also be sealed to minimize leakage. The connecting plate edges shall be double-folded and internally sealed with a silicone free elastic resin to minimize leakage. The corners of assembled exchanger packages shall also be sealed to minimize leakage. Heat exchanger assemblies shall be able to withstand temperatures of 212F. Access to all four faces of exchangers shall be provided for cleaning and inspection. Drain pans shall be provided under each the supply and exhaust sides of the exchanger, with drain connections extending to the exterior of the unit base. Drain pans shall be either galvanized or stainless steel of the same construction as provided in other unit sections. Performance The heat exchanger shall be certified to ANSI/AHRI Standard 1060 and bear the AHRI 1060 label. Performance characteristics of the heat exchanger shall be provided as defined by AHRI 1060 definitions. The heat exchangers EATR shall be less than 1% as shown by AHRI certification. Heat exchanger face velocity shall not exceed 500fpm and not exceed specified pressure drop. Performance shall match or exceed specified effectiveness. Condensate volume at design conditions shall be predicted by the air handling unit manufacturer. 206 CLCH-PRC022A-EN Mechanical Specifications Corrosion Coating (Optional) To provide protection for installations in mildly corrosive environments the air-to-air plate exchanger plates shall have an Epoxy-phenol lacquer applied coating. The extrusions, end plates and all sheet metal surfaces of the plate exchanger are to be epoxy coated. Frost Damper (Optional) Heat exchangers shall meet the leaving air temperature (LAT) as shown on the schedule while operating at the specified conditions and while operating in frost prevention mode. Frost prevention systems shall provide continuous output temperatures. Defrost systems with temperature swings due to defrost cycles will not be acceptable. Frost systems shall incorporate a partial face damper factory installed on the outside air side of the exchanger. Bypass Dampers (Optional) Opposed blade face and bypass dampers shall be provided as indicated on the schedule and drawings to modulate the plate exchanger effectiveness. Dampers shall have the same construction as the double-skin airfoil design specified in mixing sections. Bypass shall be through the center of the exchanger and shall be capable of 100% bypass. Static pressure drop through the bypass shall be calculated at the maximum economizing airflow and shall not exceed the schedule values. Multizone Sections Two-Deck Multizone Multizone section shall be provided with a cooling coil in the lower deck and a heating coil in the upper deck. Pressure drop equalization baffles shall be provided, as required, to balance air pressure drop through each deck. Multizone dampers for controlling airflow through the upper and lower decks shall be double-skin airfoil design with metal compressible jamb seals and extruded vinyl blade edge seals on all blades. Blades shall rotate on stainless steel sleeve bearings. The dampers are rated for a maximum leakage rate of 11 (cfm)/(foot squared) at 1 inch wg. Three-Deck Multizone Multizone section shall be provided with a cooling coil in the lower deck, a heating coil in the upper deck, and a bypass (neutral) center deck. Pressure drop equalization baffles shall be provided, as required, to balance air pressure drop through each deck. Multizone dampers for controlling airflow through the three decks shall be double-skin airfoil design with metal compressible jamb seals and extruded vinyl blade edge seals on all blades. Blades shall rotate on stainless steel sleeve bearings. The dampers are rated for a maximum leakage rate of 11 (cfm)/(foot squared) at 1 inch wg. Double-Duct Section Double duct section shall be provided with a cooling coil in the lower deck and a heating coil in the upper deck. Pressure drop equalization baffles shall be provided, as required, to balance air pressure drop through each deck. Triple-Duct Section Triple duct section shall be provided with a cooling coil in the lower deck, a heating coil in the upper deck, and a bypass (neutral) center deck. Pressure drop equalization baffles shall be provided, as required, to balance air pressure drop through each deck. CLCH-PRC022A-EN 207 Mechanical Specifications Paint Options Outdoor Unit Paint External surface of unit casing shall be prepared and coated with a minimum 1.5 mil enamel finish or equal. Units supplied with casing exterior factory-painted shall be able to withstand a salt spray test in accordance with ASTM B117 for a minimum of 500 consecutive hours. Unit casing exterior will be provided with manufacturer’s standard color, or alternative color when required. Optional Indoor Unit Paint In indoor units all exterior AHU panels will be made of galvanized steel. As an option, the external surface of the unit casing can be painted upon request. Units supplied with factory-painted exterior casing shall be able to withstand a salt spray test in accordance with ASTM B117 for a minimum of 500 consecutive hours. Unit casing exterior will be provided with manufacturer’s standard color, or alternative color when required. Pipe Cabinet For outdoor units, piping cabinet shall be supplied by the manufacturer (factory-assembled) and shall be of the same construction as the main unit casing. Piping cabinet shall be mounted external to the unit and shipped separate to be field-installed. Outdoor Unit Roof Trane engineered inner roofs incorporate mid-span, internal thermal breaks to eliminate thermal conduction paths from the interior of the air handler to the exterior (2-inch R13 foam-insulated). Inner/ Indoor/ roof will be installed in such a manner as to prevent air bypass between internal components. A single layer Outer/Outdoor roof is utilized above the inner roof and will be sloped at a minimum 0.125inches per foot either from one side of unit to other, or from center to sides of the unit. Roof assembly will overhang all walls of units by a 1.5-inch minimum. Silencers A rectangular silencer shall be provided to reduce airborne sound transmitted through the air handler. The silencer ratings for dynamic insertion loss and pressure drop shall be in accordance with ASTM E-477 for forward flow (air and noise in the same direction) or reverse flow (air and noise in the opposite direction) per the project's requirements. Acoustical performance within the air handler unit assembly shall be in accordance with AHRI 260. Other Sections and Options Access/Inspection Sections A section shall be provided to allow additional access/inspection of unit components and space for field-installed components as needed. The section length shall be variable to accommodate specific access, spacing, or dimensional requirements. An access door shall be provided for easy access. All access sections shall be complete with a double-wall, removable door downstream for inspection, cleaning, and maintenance. Interior and exterior door panels shall be of the same construction as the interior and exterior wall panels, respectively. All doors downstream of cooling coils shall be provided with a thermal break construction of door panel and door frame. Blender Section An air blender section shall be provided to mix outside and return air, minimize stratification, and reduce the risk of frozen coils. The blender size, space upstream, and space downstream shall be factory engineered for proper performance. 208 CLCH-PRC022A-EN Mechanical Specifications Diffuser Section A diffuser section shall be provided immediately downstream of the fan section. The diffuser shall provide equal air distribution to blow-thru components immediately downstream of the diffuser. Turning and Discharge Plenum Sections Plenums shall be provided to efficiently turn air and provide sound attenuation. Discharge plenum opening types and sizes shall be scaled to meet engineering requirements. The vertical discharge plenum height may be scaled to accommodate the appropriate discharge duct height. The horizontal discharge plenum length may be scaled to accommodate necessary dimensional constraints. Plenum Attenuation Panels Discharge plenum panels shall include an acoustical liner. The liner shall be fabricated from stainless steel perforated material to prevent corrosion and designed to completely encapsulate fiberglass insulation. The perforation spacing and hole size shall be such as to prevent insulation breakaway, flake off, or delamination when tested at 9,000 fpm, in accordance with UL Specification 181. Controls Combination Starter–Disconnects An IEC combination starter/disconnect shall be provided for each fan motor. Each starter / disconnect shall be properly sized, factory mounted in a full metal enclosure, and wired to the fan motor to facilitate temporary heating, cooling, ventilation, and/or timely completion of the project. Starter / disconnects shall include a circuit breaker disconnect with a through-the-door interlocking handle (external-mounted starters - sizes 3-120) or a beside-the-door interlocking handle (internalmounted starters - sizes 3-120) spring loaded and designed to rest only in the full ON or OFF state and shall be lockable in these states. A concealed defeater mechanism shall allow entry into the enclosure when the handle is in the ON position. The starter package shall also include: • Hand-Off-Auto (H-O-A) selector switch • Two N.O. auxiliary contacts • Overload heaters • Manual reset overloads • 120V control transformer with fusing and secondary grounding Units with factory-mounted controls shall also include power wiring from the starter control transformer to the secondary control system transformers, and start-stop wiring from the direct digital controller start-stop relay to the starter H-O-A switch. Combination VFD and Disconnects A combination VFD/disconnect shall be provided for each fan motor. Each VFD/disconnect shall be properly sized, factory mounted in a full metal enclosure, wired to the fan motor, and commissioned to facilitate temporary heating, cooling, ventilation, and/or timely completion of the project. VFD/disconnects shall include a circuit breaker disconnect with a through-the-door interlocking handle (external-mounted starters - sizes 3-120) or a beside-the-door interlocking handle (internal-mounted starters - sizes 3-120) spring loaded and designed to rest only in the full ON or OFF state and shall be lockable in these states. A concealed defeater mechanism shall allow entry into the enclosure when the handle is in the ON position. The VFD package shall also include: CLCH-PRC022A-EN • Electronic manual speed control • Hand-Off-Auto (H-O-A) selector switch • Inlet fuses to provide maximum protection against inlet short circuit 209 Mechanical Specifications • Current limited stall prevention • Auto restart after momentary power loss • Speed search for starting into rotating motor • Anti-windmill with DC injection before start • Phase-to-phase short circuit protection • Ground fault protection Units with factory-mounted controls shall include a control transformer with sufficient capacity to support both the VFD and controls requirements, binary output on/off wiring, analog output-speedsignal wiring, and all interfacing wiring between the VFD and the direct digital controller. The VFD shall be UL508C listed and CSA certified and conform to applicable NEMA, ICS, NFPA, and IEC standards. Optional Bypass Bypass relays and bypass circuitry with a VFD/OFF/Bypass selector switch shall be provided. Starter/Disconnect or VFD Enclosure Options Starter or VFD shall be mounted externally on the fan section in a NEMA Type 1 enclosure (unit sizes 3-120) or internally in a NEMA Type 4 equivalent unit casing (unit sizes 3-120) within a dedicated controls section or housed fan section. The internal enclosure shall be an integral part of the unit casing to allow for thermal venting to casing interior, but shall be accessible from unit exterior through access door. Internally mounted starters/VFDs shall have doors with the same construction as other doors on unit. An external disconnect shall be mounted beside the access door to the starter or VFD to disconnect full power from starter/VFD, lights, or control power. Factory-Mounted DDC System Factory-mounted direct-digital control (DDC) system shall be engineered, mounted, wired, and tested by the air handler manufacturer to reduce installed costs, improve reliability, and save time at unit startup. Each control system shall be fully functional in a stand-alone mode or may be tied to a building automation system with a single pair of twisted wires. All factory-mounted controls shall be covered by the air handler manufacturer’s standard warranty. Direct Digital Controller Field-Programmable Controller A dedicated, programmable, direct digital-controller with the appropriate point capabilities shall be unit-mounted on each air-handling unit. A portable screen and keypad shall be provided to facilitate local monitoring, troubleshooting, and changing of setpoints. The touch pad shall be able to quickly plug into other factory-configured controllers by the same manufacturer. Factory-Mounted Control Options—Electronic End Devices All factory-mounted control devices shall be provided to accommodate integration into existing building systems. Devices provided shall be wired to standard point locations of a unit-mounted direct digital controller or terminal block for a remote controller. Mixing Section Damper Actuators Spring return actuators shall be mounted with the outdoor air damper linked as normally closed and the return-air damper linked as normally open. Airflow Measuring Stations (Traq Dampers) Airflow monitoring stations shall provide a 2 to 10 Vdc signal, which corresponds to cfm, for controlling and documenting airflow. 210 CLCH-PRC022A-EN Mechanical Specifications Temperature Sensors Unit-mounted temperature sensor material shall be selected for ease of integration into existing BAS control systems. Temperature sensor material types include: • 1k ohm RTD, Platinum 385 • 1k ohm RTD, Nickel • 10k ohm, Type II Thermistor • 10k ohm, Type III Thermistor • 20k ohm, Type IV Thermistor • 100k ohm, Type II Thermistor Fan Discharge Temperature Sensors A button or probe temperature sensor shall be mounted in the fan discharge. The sensor material shall be selected for ease of BAS integration. Averaging Temperature Sensors An averaging temperature sensor shall be serpentined across the functional section. Bends of the capillaries shall be curved and fastened with capillary clips to prevent crimping and minimize wear. The sensor material shall be selected for ease of BAS integration. Low-Limit Switches A double-pole low limit switch shall be wired to a momentary push-button reset circuit. Capillaries are serpentined across the entering side of the coil. The bends of the capillaries shall be curved and fastened with capillary clips to prevent crimping and minimize wear. A separate low limit shall be provided for each coil in a coil stack. Airflow Switches A differential pressure switch piped to the discharge and suction sides of the fan shall indicate fan status. Dirty Filter Switches A differential pressure switch piped to both sides of the filter shall indicate filter status. Condensate Overflow Switches A float switch conforming to UL 508 shall be factory-installed in the drain pan that will detect a high condensate water level and be used to shut off the air handler in the event that the primary drain is blocked to comply with IMC 2006. The float switch shall be located at a point higher than the primary drain line connection and below the overflow rim of the drain pan. Customer Interface Relays Five-amp double-pole, double-throw relays shall be provided as required for each binary output of the controller for customer interface to: CLCH-PRC022A-EN • Motor starters of supply, return, and exhaust fans • Relief dampers • Pumps • Condensing units 211 Mechanical Specifications Field-Mounted Control Options Control Valves Control valves shall be provided by the air-handling unit (AHU) manufacturer and field-piped by the piping contractor. Power and signal wiring shall be extended to a factory-installed external junction box to facilitate field-wiring and to maintain air leakage integrity of the casing. Space Temperature Sensors Thermistor-type sensors shall be provided by the air-handling unit (AHU) manufacturer as required for field wiring. Outdoor Air Sensors Thermistor-type sensors shall be provided by the air-handling unit (AHU) manufacturer as required for field wiring. 212 CLCH-PRC022A-EN NOTES NOTES CLCH-PRC022A-EN 213 NOTES 214 CLCH-PRC022A-EN NOTES CLCH-PRC022A-EN 215 Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. © 2013 Trane All rights reserved CLCH-PRC022A-EN 10 Sep 2013 We are committed to using environmentally Supersedes CLCH-PRC015-EN (12 Dec 2012) conscious print practices that reduce waste.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Create Date : 2013:09:10 12:50:34-04:00 Modify Date : 2013:09:10 12:50:34-04:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 10.1.4 (Windows) Format : application/pdf Title : untitled Document ID : uuid:d2e03914-d76d-4f76-81d7-0b8fed11a67f Instance ID : uuid:2fe3e552-9043-4913-947c-c7746ace2601 Page Count : 216EXIF Metadata provided by EXIF.tools