Transact Campus LWI30XX002 900 MHz Wireless Module User Manual LC3000 Install 2 9

Blackboard Inc. 900 MHz Wireless Module LC3000 Install 2 9

Users Manual

LC3000 Laundry Center
Installation and Setup Guide
Copyright © 2005 Blackboard Inc.® All rights reserved. No part of this publication may be
reproduced or used in any form or by any means—graphic, electronic, or mechanical including
photocopying, recording, taping, or information storage and retrieval systems—without the
express written permission of Blackboard Inc. Information contained in this document is subject to
change without notice.
The following information applies to wired LC3000 systems equipped with LCM20s only.
The following information applies to wireless systems equipped with LWIs and LE3/BRIDGES only.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Part 15.21: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this
equipment. Such modifications could void the user’s authority to operate the equipment.
Blackboard Inc. LC3000
Test ed To C omp ly
With FCC Standards
FOR HOME OR OFFICE USE
This Class A digital apparatus complies with
Canadian ICES-003
Blackboard Inc. LWI30xx
Test ed To C omp ly
With FCC Standards
FOR HOME OR OFFICE USE
Date: 9/27/07 Doc. No.: 1135
LC3000 Laundry Center Installation i
September 27, 2007
Document 1135
CONTENTS
1 LC3000 Laundry Center Installation
3 Laundry Center Components
3 LC3000 Components
4 Laundry Center Installation Overview
5 LC3000 Laundry Reader Installation
6 Install the LC3000 Enclosure
7 LC3000 Laundry Reader Configuration
8 Configure LC3000 Reader using front panel
8 Configure LC3000 Reader using RS-232
8 Configure LC3000 Reader using Telnet
9 Wired Laundry Machine Interface Installation
10 Laundry Controller Multiplexer (LCM20) Installation
10 Install the LCM20 in the LC3000
11 Install External LCM20(s) (if required)
12 Laundry Controller Interface (LCI) Installation
12 Install Maytag LCI3010 in Laundry Machine
14 Install Alliance/Speed Queen LCI3020 in Laundry Machine
15 Install Whirlpool LCI3030 in Laundry Machine
LC3000 Laundry Center Installation ii
September 27, 2007
Document 1135
16 Wireless Laundry Machine Interface Installation
17 Wireless Bridge LE3/BRIDGE Installation
18 Laundry Wireless Interface Module (LWI) Installation
19 Install the LWI3010 Module for Maytag laundry machines
20 Install the LWI3020 Module for Alliance/Speed Queen laundry machines
22 Appendix
22 Features
23 Transaction Process
24 Manager Menus
25 Laundry Components Dimensions and Weight
27 LC3000 Laundry Reader Default Configuration Settings
27 Restore Default Settings
28 MW9010/MW9012 Laundry Reader Retrofit
28 Configure LC3000 for retrofit (wired laundry centers only)
LC3000 LAUNDRY CENTER INSTALLATION
LC3000 Laundry Center Installation 1
LC3000 LAUNDRY CENTER INSTALLATION
September 27, 2007
LC3000 LAUNDRY CENTER INSTALLATION
This manual provides instructions for selecting, installing, and configuring the
Blackboard Laundry Center using the LC3000 Laundry Reader.
The LC3000 Laundry Reader controls laundry machines across a laundry Center
network and Blackboard Transaction System (BbTS) and communicates with users
interface through a display, keypad, and mag-stripe reader. The network connections
are 10/100 Base-T or RS-485, machine connections are wired or wireless.
Laundry Readers connecting to a Universal Edition Host in RS-485 mode require
an IP Converter (IPC).
Universal Edition using RS-485 network connections DOES NOT support wireless
communications with laundry machines.
Wired Solution
The wired solution reader supports up to 60 laundry machines across three connected Multiplexers. The first
Multiplexer is installed inside the LC3000.
Each machine uses a Laundry Controller Interface (LCI), a wiring harness inside the machine, to facilitate
communications between the laundry machine controller and LC3000 Laundry Reader.
FIGURE 1: Wired LC3000 Laundry Center
Campus
Network
Laundry Reader
(LC3000)
w/
Multiplexer
(LMC20)
Multiplexer
(LCM20)
w/
Enclosure
(LE3/PSENCL)
Multiplexer
(LCM20)
w/
Enclosure
(LE3/PSENCL)
Belden 8723, 5502UE cable
or equivalent
Laundry Controller Interface
(LCI)
inside each machine
1 ---------------------- 20 21 -------------------- 40 41 -------------------- 60
(400’ max)
Belden 8723, 5502UE cable
or equivalent
LC3000 LAUNDRY CENTER INSTALLATION
LC3000 Laundry Center Installation 2
LC3000 LAUNDRY CENTER INSTALLATION
September 27, 2007
Wireless Solution
Up to 60 laundry machines can be connected wirelessly to the LC3000 using a Wireless Bridge (LE3/BRIDGE). Each
Bridge communicates with laundry machines within 60 feet. Multiple Wireless Bridges can be used if stone or metal
obstructions reduce the range. Each laundry machine connects to a Laundry Wireless Interface installed inside the
machine. The Laundry Wireless Interface (LWI), a wiring harness and wireless module, facilitates communications
between a laundry machine and the LC3000 Laundry Reader, via the Wireless Bridge.
Campus
Network
Laundry Reader
(LC3000)
(machines 1 - 60)
Belden 5502UE cable
or equivalent
Laundry Wireless Interface
(LWI)
installed in each machine
Wireless Bridge
(LE3/BRIDGE)
(60 feet)
1 ------------------------------------------ 60
FIGURE 2: Wireless Laundry Center Solution
LAUNDRY CENTER COMPONENTS
LC3000 Laundry Center Installation 3
LAUNDRY CENTER COMPONENTS
September 27, 2007
LAUNDRY CENTER COMPONENTS
LC3000 Components
COMMON COMPONENT
Laundry Reader LC3000 Each LC3000 supports up to 60 machines (stacked units count as 2 machines).
Wired installations require LCM20(s) and LCIs.
Wireless installations require LE3/BRIDGE(s) and LWI(s).
WIRED COMPONENTS
Laundry Controller
Multiplexer
LCM20 Each LCM20 supports 20 wired machines. The first LCM20 is installed inside the LC3000. The
second and third LCM20s each require a Power Supply Enclosure (LE3/PSENCL).
Power Supply /
Enclosure
LE3/PSENCL An LE3/PSENCL power supply/enclosure is required for the 2nd and 3rd LCM20s. A 2nd LCM20
is required if the LC3000 is controlling more than 20 machines, a 3rd LCM20 is required if the
LC3000 is controlling more than 40 machines.
Interfaces
Maytag LCI3010 All Maytag commercial debit-card ready machines are supported by the LCI3010. An LCI3010 is
required for each single machine or for a complete stacked unit (both top and bottom unit
supported by a single LCI3010).
Speed Queen LCI3020 Only Speed Queen NetMaster and MDC models are supported by the LCI3020. An LCI3020 is
required for each single machine. Two LCI3020s are required to support a stacked unit.
Whirlpool LCI3030 Only Whirlpool Advantech models are supported by the LCI3030. A LCI3030 is required for
each single machine. Two LCI3030s are required to support a stacked unit.
WIRELESS COMPONENTS
Wireless Bridge LE3/BRIDGE Each LE3/BRIDGE is the hub of a wireless network for up to 60 machines. The LE3/BRIDGE
needs to be no further than 60 feet from each of the machines on its wireless network. The LE3/
BRIDGE connects to the LC3000 via a standard CAT5 patch cable.
Interfaces
Maytag LWI3010 All Maytag commercial debit-card ready machines are supported by the LWI3010. A LWI3010 is
required for each single machine or for a complete stacked unit (both top and bottom units are
supported by a single LWI3010).
Speed Queen LWI3020 Speed Queen NetMaster and MDC models are supported by the LWI3020. A LWI3020 is
required for each single machine or for a complete stacked unit (both top and bottom units are
supported by a single LWI3020).
LAUNDRY CENTER INSTALLATION OVERVIEW
LC3000 Laundry Center Installation 4
LAUNDRY CENTER INSTALLATION OVERVIEW
September 27, 2007
LAUNDRY CENTER INSTALLATION OVERVIEW
1Configure Laundry Machines in BbTS.
2LC3000 Laundry Reader Installation (page 5)
3LC3000 Laundry Reader Configuration (page 7)
4Wired Laundry Machine Interface Installation (page 9) or Wireless Laundry Machine Interface Installation
(page 16)
(see BbTS Unix Reference Manual)
(see BbTS Universal System Administration Guide)
LC3000Config
MA C A dd re ss
IP Address
DHCP Status
Communic ation
Mode
DHCP
Reader Address Baud Rate
RS-485 Com munications
I P C o m m u ni c a t i o n s
IP Address
Subnet Mask
Default Router/
Gat ewa y Host IP Add ress
Disa bled
Enabled
Host DHCP Telnet Enable S ervi ce Card
Enable
Save
Disabl e
LC3000 LAUNDRY READER INSTALLATION
LC3000 Laundry Center Installation 5
LC3000 LAUNDRY READER INSTALLATION
September 27, 2007
LC3000 LAUNDRY READER INSTALLATION
The LC3000 Laundry Reader must be mounted on a wall in a location that is convenient to cardholders and wiring
requirements.
LC3000 Mounting Location Considerations
120 VAC power availability
Connect to 120 VAC @ 60 Hz. Connect only to a 15A maximum branch circuit protection or equivalent. Use a
circuit breaker or switch to disconnect power when installing or removing the LC3000.
Network communications availability (RS-485 or 10/100 Base T)
Wiring distance limitations
- RS-485 Communications 4000' total per loop
- 10/100 Base-T Communications 300' from the network switch port
Ease of cable routing to laundry machines (if wired configuration)
Installation height regulations
Cardholder convenience
Mounting hardware required: .25” appropriate to surface.
Prepare Enclosure
The Reader can be mounted flush to the wall with wiring
behind the wall; or it can be surface-mounted with wiring in
conduit exterior of the wall. Before mounting the enclosure,
remove knockouts necessary for routing wires and/or attaching
conduits. Remove only the knockouts required for your
installation.
AC power knockouts accept 1/2'' conduit fittings.
All other knockouts accept 3/4'' conduit fittings.
Flush-mount: route machine wires, if wired, through the 3''
x 3'' cutout.
Surface-mount: Remove conduit knockouts on the top
and bottom of the enclosure for routing wire to machines.
Two power knockouts are provided in the upper right.
Flush-mount: Remove the knockout on the back side.
Surface-mount: Remove the knockout on the top.
ACMAIN
Mount Mount
AC power knockouts
machine wires
use side
knockouts
only if
surface
mounting
FIGURE 3: Mounting & Knockouts
flush-mount
LC3000 LAUNDRY READER INSTALLATION
LC3000 Laundry Center Installation 6
LC3000 LAUNDRY READER INSTALLATION
September 27, 2007
Install the LC3000 Enclosure
1Inside the LC3000, remove the power supply cover to access the upper
right mounting hole.
Protect power supply from debris while mounting the enclosure.
2Secure enclosure to a wall using hardware appropriate to wall material.
Mounting holes accept up to 1/4'' hardware.
Disconnect external AC power when installing wiring.
3Strip back insulation on AC wire .28" to prevent bare wire exposure
when installed in AC terminal block.
4Install wires into the AC terminal block as shown in Figure 5, tighten
the screws to 5 - 7 in-lbs., and replace power supply cover.
Ensure 120VAC wiring is confined within power supply compartment when cover
is reinstalled to maintain UL compliance.
5Reconnect external AC power.
6Connect to Network.
The LC3000 provides for both 10/100 Base-T, TCP/IP and RS-485 BbTS network
connections.
Once you connect the LC3000 to the network, configure the LC3000 for the
network (LC3000 Laundry Reader Configuration (page 7).)
FIGURE 4: Power Installation
Line
Ground
Neutral
FIGURE 5:Power Connections
LC3000 LAUNDRY READER CONFIGURATION
LC3000 Laundry Center Installation 7
LC3000 LAUNDRY READER CONFIGURATION
September 27, 2007
LC3000 LAUNDRY READER CONFIGURATION
The Laundry Reader must be configured to communicate with the BbTS network.
LC3000 Default Configuration
DHCP enabled
NP (host) IP address assigned by DHCP server
Configuration Methods
Configure the LC3000 Laundry Reader to interface with BbTS, using one of three modes:
Configure LC3000 Reader using front panel (page 8)
Configure LC3000 Reader using RS-232 (page 8)
The Reader’s RS-232 can be used to connect to a computer using Hyperterminal
Configure LC3000 Reader using Telnet (page 8)
The Reader can be configured via IP if using Ethernet connections once it is assigned an IP address.
OFFLINE: An asterisk (*) in the first line, second to the last position indicates the terminal is offline.
LC3000Config
MAC Address
IP Address
DHCP Status
Communication
Mo d e
DHCP
Reader Address Baud Rate
RS-485 Communications
IP Communications
IP Address
Subnet Mask
Default Router/
Gateway Host IP Address
Disabled
Enabled
Host DHCP Telnet Enable Service Card
Enable
Save
Disable
FIGURE 6: LC3000 Laundry Reader Configuration
LC3000 LAUNDRY READER CONFIGURATION
LC3000 Laundry Center Installation 8
LC3000 LAUNDRY READER CONFIGURATION
September 27, 2007
Configure LC3000 Reader using front panel
1Swipe a Service Card, and then press NEXT on Reader to start configuration
process.
2Adjust each setup parameter using the keys displayed on the Terminal.
ACCEPT - Accept displayed value and advance to next setting.
CHANGE - Change displayed value.
ABORT - Abort configuration process.
To update the IP address and related information, press CHANGE when the
parameter is displayed; then type the number using zeroes (0) as placeholders.
3Press NEXT when the End of Config Setup message displays, which will save the settings and reboot the reader.
The terminal may be offline for several minutes until it synchronizes with the Host.
Configure LC3000 Reader using RS-232
1Connect a cable from a computer’s serial port to the
port on the LC3000 door labelled “RS-232 CONFIG”.
Cable connections are shown in RS-232 Config Port
Connections.
2Open a terminal program (e.g. Hyperterminal) and
establish connection settings:
9600 baud
•1 stop
no parity
no flow control
3Log in using the default password: IPrdr4U.
The password is case sensitive. Consider changing
the password.
4At the prompt, type config and press Enter.
See LC3000 Laundry Reader Configuration (page 7) for
configuration items.
5When complete, disconnect cable from RS-232 CONFIG.
Configure LC3000 Reader using Telnet
1Open a Telnet session to the LC3000 Reader’s IP address.
2Log in using the default password: IPrdr4U.
The password is case sensitive. Consider changing the password.
3At the prompt, type the following command and press Enter to start configuration:
config to configure the LC3000. Refer to Figure 6: LC3000 Laundry Reader Configuration (page 7) for the
configuration options.
FIGURE 8: LC3000 Configuration Menu
IPrdr4U
RS-232 Config Port Connections
Signal LC3000
(RJ-12)
PC Serial Port
DB9 Connector
Ground Pin 1 Pin 5
Receive (RX) Pin 3 Pin 3
Transmit (TX) Pin 4 Pin 2
WIRED LAUNDRY MACHINE INTERFACE INSTALLATION
LC3000 Laundry Center Installation 9
WIRED LAUNDRY MACHINE INTERFACE INSTALLATION
September 27, 2007
WIRED LAUNDRY MACHINE INTERFACE INSTALLATION
The wired Blackboard laundry solution supports up to 60 laundry machines. Multiplexers (LCM20s) facilitate up to 20
wired machine connections each. In laundry centers with 20 or fewer machines, a single Multiplexer is installed inside
the LC3000 enclosure. Laundry Centers supporting more than 20 machines require additional Multiplexers and
enclosures for mounting, power and protection. Order an enclosure, LE3/PSENCL, for each additional Multiplexer. The
Reader supports three (3) Multiplexers.
Each Multiplexer connects to 20 machines, using a Laundry Controller Interface installed inside the machine. The
Laundry Controller Interface (LCI) is a wiring harness that communicates with the laundry machine controller.
Wired Installation Overview
Install the LCM20 in the LC3000 (page 10)
Install External LCM20(s) (if required) (page 11)
Only laundry centers with more than 20 laundry machines need External LCM20s. Each LCM20 communicates
with up to 20 laundry machines.
Laundry Controller Interface (LCI) Installation (page 12)
Campus
Network
Laundry Reader
(LC3000)
w/
Multiplexer
(LMC20)
Multiplexer
(LCM20)
w/
Enclosure
(LE3/PSENCL)
Multiplexer
(LCM20)
w/
Enclosure
(LE3/PSENCL)
Belden 8723, 5502UE cable
or equivalent
Belden 8723, 5502UE cable
Laundry Center Interface
(LCI)
installed in each machine
1 ---------------------- 20 21 -------------------- 40 41 -------------------- 60
(400’ max)
or equivalent
FIGURE 9: LC3000 Laundry Center Solution
LAUNDRY CONTROLLER MULTIPLEXER (LCM20) INSTALLATION
LC3000 Laundry Center Installation 10
LAUNDRY CONTROLLER MULTIPLEXER (LCM20) INSTALLATION
September 27, 2007
LAUNDRY CONTROLLER MULTIPLEXER (LCM20) INSTALLATION
LCM20 Placement Considerations
120 VAC power availability
Connect to 120 VAC @ 60 Hz. Connect only to a 15A maximum branch circuit protection or equivalent. Use a
circuit breaker or switch to disconnect power when installing or removing the LC3000.
Network communications availability (RS-485 or 10/100 Base-T)
Wiring distance limitations
- RS-485 Communications 4000' total per loop
- 10/100 Base-T Communications 300' from network switch port
- 400' from Multiplexer (LCM20) to the laundry machines
Ease of cable routing to laundry machines
Install the LCM20 in the LC3000
1With the enclosure door open, position the LCM20 over the six
standoffs, with component side facing out (see Figure 10).
2Secure the LCM20 using #4-40 screws from the hardware kit.
3Set the rotary address switch to position 0. Refer to Figure 10.
4Connect LCM20 to the LC3000 Reader, using the provided RJ-45
communication cable.
5Route 4-conductor cables from each LCM20 terminal block to a
laundry machine (see Figure 11).
Consider marking each cable uniquely for easy identification.
Do not connect power to the LCM20 Board until all machine
interfaces are terminated.
ACMAIN
L N G
0123
4
5
6
7
8
9
A
B
C
D
EF
FIGURE 10: LCM20 in LC3000
FIGURE 11: LCM20 Connections
ACMAIN
L N G
012
3
4
5
6
7
8
9
A
B
C
D
EF
LINK/ACT
NET
100M
HOST RS-485
LCM20 RS-485
BRIDGE RS-485
AUX RS-485
Power
LWI
CONFIG
RS-232
CONFIG
to external LCM20
(Belden 5502UE cable or equivalent)
LAUNDRY CONTROLLER MULTIPLEXER (LCM20) INSTALLATION
LC3000 Laundry Center Installation 11
LAUNDRY CONTROLLER MULTIPLEXER (LCM20) INSTALLATION
September 27, 2007
Install External LCM20(s) (if required)
If your Laundry Center has more than 20 machines, an external LCM20
and LE3/PSENCL are required.
1Inside the LE3/PSENCL, remove the power supply cover to access the
upper right mounting hole (Figure 12).
Protect power supply from debris while mounting the enclosure.
2Secure the enclosure to the wall using hardware for wall material.
Mounting holes accept up to 1/4” hardware.
Disconnect external AC power when installing wiring.
3Strip back AC wire insulation .28", install wires into AC terminal block as
shown in Figure 13, tighten screws to 5-7 in-lbs., and replace power supply cover.
Prevent bare wire from being exposed when installed in the AC terminal block.
UL compliance: Ensure 120VAC wiring is within power supply compartment
when cover is replaced.
4Position LCM20, component side facing out, over the six
standoffs, and secure using the #4-40 screws from the
hardware kit.
5Set rotary address switch to position 1 or 2.
Position 1: machines 21 - 40
Position 2: machines 41 - 60.
6Route Belden cable from external LCM20 to LCM20
mounted inside the LC3000 enclosure.
Refer to LCM20 and LE3/PSENCL Connections
(page 11) for cable termination.
7Route a 4-conductor cable from each laundry machine to
an LCM20 terminal block (TB1 - TB20).
Consider marking cables uniquely for easy identification.
Do not connect LCM20 power until all machine interfaces
are terminated at both the laundry machine and the
LCM20.
FIGURE 12: Power Supply access
Line
Ground
Neutral
FIGURE 13: Power Connections
ACMAIN
L N G
0123
4
5
6
7
8
9
A
B
C
D
EF
power
to LCM20 in LC3000
rotary
switch
(set to
1 or 2)
(Belden 5502UE cable or equivalent)
FIGURE 14: LCM20 and LE3/PSENCL Connections
0123
4
5
6
7
8
9
A
B
C
D
EF
LAUNDRY CONTROLLER INTERFACE (LCI) INSTALLATION
LC3000 Laundry Center Installation 12
LAUNDRY CONTROLLER INTERFACE (LCI) INSTALLATION
September 27, 2007
LAUNDRY CONTROLLER INTERFACE (LCI) INSTALLATION
The Laundry Controller Interface (LCI) is installed inside each laundry machine. The Laundry Controller Interface (LCI)
is a wiring harness that connects to the laundry machine controller. The LCI is then connected to the Laundry Controller
Multiplexer (LCM20) to communicate with Laundry Reader.
The Laundry Controller Interface (LCI) model used depends on the laundry machine manufacturer. See Laundry
Center Components (page 3) for Laundry Machine Interface (LCI) models. Each model includes cables, splices and
wire ties.
To prevent tampering, run cable through flexible metal conduit from LCM20 to the back of the machine. If
flexible metal conduit is not used, then a strain relief must be used to prevent damage to the cable.
LCI Installation instructions included are:
Install Maytag LCI3010 in Laundry Machine (page 12)
Install Alliance/Speed Queen LCI3020 in Laundry Machine (page 14)
Install Whirlpool LCI3030 in Laundry Machine (page 15)
Install Maytag LCI3010 in Laundry Machine
Two cables are included to support stacked dryers. If installing a single machine, discard the two-wire cable.
1Remove the operator console (with display and switches) from the machine.
Only the screws in the top two corners need to be removed.
2Route the 4-conductor cable from the LCM20 into the laundry machine for connection to the LCI.
3Attach female connectors from the hardware kit to the machine end of the 4-conductor cable.
4Insert the LCI male bullet connectors into the female connectors of the 4-conductor cable (white to white, black to
black, etc.) See Figure 15.
Stacked Machine: connect the two-wire harness to the black and green wires, as shown.
5Install the LCI into the machine circuit board’s six-pin Molex (see Figure 16), and if a stacked dryer, adjacent 2-pin
Molex.
1
2
3
4
1
2
3
4
white
black
red
black
red
black
white
6-pin Molex
Washing Machine
Maytag
Laundry Controller
Multiplexer (LCM20)
FIGURE 15: Single Maytag Machine
white
red
black
green
green
5
6
or equivalent 4-conductor cable
BELDEN 8723
LAUNDRY CONTROLLER INTERFACE (LCI) INSTALLATION
LC3000 Laundry Center Installation 13
LAUNDRY CONTROLLER INTERFACE (LCI) INSTALLATION
September 27, 2007
6Use the wire ties and wire tie blocks included in the hardware kit to dress the wires, and replace the laundry
machine operator console.
7Terminate the 4-conductor cable at the LCM20 1 x 4 terminal block(s).
Switch the green and white wires if the signals do not correspond to the machines as labeled.
1
2
3
4
1
2
3
4
white
black
red
black
red
black
white
6-pin Molex
Stacked Dryer
Maytag Laundry Controller
Multiplexer (LCM20)
white
red
black
green green
5
6
1
2
1
2
3
4
FIGURE 16: Maytag Stacked Machine
or equivalent 4-conductor cable
BELDEN 8723
LAUNDRY CONTROLLER INTERFACE (LCI) INSTALLATION
LC3000 Laundry Center Installation 14
LAUNDRY CONTROLLER INTERFACE (LCI) INSTALLATION
September 27, 2007
Install Alliance/Speed Queen LCI3020 in Laundry Machine
Two LCI3020s must be ordered when wiring to a stacked dryer.
1Remove the operator console from the machine.
Refer to the Speed Queen service manual.
2Route the 4-conductor cable from the LCM20 into the machine (see Figure 17).
Stacked Machine: run two cables.
3Attach female bullet connectors from the hardware kit to the machine end of the 4-conductor cable.
Use a strain relief or other means to protect and secure the cable where it enters the machine.
4Insert the LCI male bullet connectors into the female connectors. (white to white, black to black, etc.).
Stacked Machine: perform the same process on the second cable.
5Insert the four-pin Molex connector into the machine circuit board, as illustrated in Figure 17.
Stacked Machine: insert the second four-pin Molex connector into the second machine circuit board.
Some Speed Queen machines have a 1 x 7 header; in this case, the LCI 1 x 4 header fits onto pins 1 - 4, labelled
START IN and AVAIL OUT.
6Use the wire ties and blocks included in the hardware kit to dress the wires.
7Terminate 4-conductor cable at the LCM20 1 x 4 terminal block(s).
1
2
3
4
1
2
3
4
white
black
red
black
red
black
white
4-pin Molex
Speed Queen Laundry Machine
Laundry Controller
Multiplexer (LCM20)
FIGURE 17: Alliance/Speed Queen Machine (LCI3020)
white
red
black
green
green
or equivalent 4-conductor cable
BELDEN 8723
LAUNDRY CONTROLLER INTERFACE (LCI) INSTALLATION
LC3000 Laundry Center Installation 15
LAUNDRY CONTROLLER INTERFACE (LCI) INSTALLATION
September 27, 2007
Install Whirlpool LCI3030 in Laundry Machine
Stacked dryers require two LCI3030s.
1Remove the operator console from the machine.
Refer to Whirlpool service manual.
2Route the 4-conductor cable from the LCM20 into the machine.
If the installation is for a stacked machine, route two cables.
3Attach female connectors from the hardware kit to the machine end of the 4-conductor cable wires.
Use a strain relief or other means to protect and secure the cable where it enters the machine.
4Insert the LCI male bullet connectors into the female connectors (white to white, black to black, etc.).
Stacked Machine: the additional two-wire harness must be connected as shown in Figure 18. The second LCI fits
into the second, independent circuit board as illustrated.
5Attach the orange wire female disconnect to the M1 spade lug and the black wire with the female disconnect to the
M2 spade lug on the controller board.
6Connect the 4-pin Molex to the COIN #1 mating connector on the laundry machine controller board.
7Use the wire ties and wire tie blocks, included in the hardware kit, to dress the wires.
8Terminate 4-conductor cable at the LCM20 1 x 4 terminal block.
Be sure terminal block numbers match laundry machine numeric identifiers.
The Whirlpool control board must be configured for the coin drop, in addition to the configuration for the
BbTS host.
1
2
3
4
red
black
white
Whirlpool Advantech Laundry Machine
Laundry Controller
Multiplexer (LCM20)
BELDEN 8723
or equivalent 4-conductor cable
FIGURE 18: Whirlpool/Advantech Single Machine (LCI3030)
white
red
black
green
green
COIN 1
M2
WIRELESS LAUNDRY MACHINE INTERFACE INSTALLATION
LC3000 Laundry Center Installation 16
WIRELESS LAUNDRY MACHINE INTERFACE INSTALLATION
September 27, 2007
WIRELESS LAUNDRY MACHINE INTERFACE INSTALLATION
The LC3000 Laundry Reader supports 60 wireless laundry machine connections. Laundry machines communicate with
the wireless laundry network using Laundry Wireless Interfaces. The Laundry Wireless Interface (LWI) is a wiring
harness and wireless module. The LWI communicates with the Laundry Reader via a Wireless Bridge(s) (LE3/
BRIDGE). The Bridge and LWI communicate over an RF radio link.
Wireless Laundry Center Installation Overview
1Configure laundry machines in BbTS and download configurations to the Reader.
See BbTS Reference Manual (Unix) or BbTS System Administrator Guide (Universal).
2Apply power to the LC3000 Reader and make sure that it is online. (page 17)
3Select the appropriate hardware and mount the LE3/BRIDGE enclosure. (page 18)
4Configure LC3000 Reader using front panel (page 8)
Each laundry machine is assigned a number between 1 and 60. The LC3000 displays this number for customer
machine selection and sends the pulse command to the corresponding LWI. Configuring the LWI creates the
relationship between the machine number and LWI.
5Laundry Wireless Interface Module (LWI) Installation (page 18)
All washers and dryers must be defined at the host server before the LWI modules can be configured. The
machine type (washer/dryer), manufacturer, and stack configuration are included in the host server
configuration options.
Campus
Network
Laundry Reader
(LC3000)
(machines 1 - 60)
Belden 5502UE cable
or equivalent
Laundry Wireless Interface
(LWI)
installed in each machine
Wireless Bridge
(LE3/BRIDGE)
(60 feet)
1 ------------------------------------------ 60
FIGURE 19: Wireless Laundry Center Solution
WIRELESS LAUNDRY MACHINE INTERFACE INSTALLATION
LC3000 Laundry Center Installation 17
WIRELESS LAUNDRY MACHINE INTERFACE INSTALLATION
September 27, 2007
Wireless Bridge LE3/BRIDGE Installation
The LE3/Bridge module must be configured prior to being installed. This requires programming a network ID and
configuring the module as a Bridge.
Configure the LE3/BRIDGE
1Apply power to the LC3000 Reader and make sure that
it is online.
2Install the configuration cable (p/n 044-042-043) into the
RJ-12 Jack labeled LWI CONFIG.
This cable is supplied with the LE3/BRIDGE.
3Plug the 22-pin Molex connector into the mating
connector of the Bridge module.
4The LC3000 will detect the module, and load the current
version of software if necessary. The top two lines of the
display show the machine ID, software version and
network ID.
The factory default for the network ID and machine ID is
FF. If the module has been assigned previously, the
message Already Assigned is displayed. In this case,
enter 1 for yes, to reassign the network ID.
5Enter the network ID.
Network values are 1 through 7.
6Press the OK soft key.
Always select a network ID that has not been chosen on a nearby LC3000 Laundry Center wireless
network. A nearby network is considered any installation within the same building and/or less then 500
feet.
7Set the LWI type by selecting 2 to configure the module as a Bridge.
8Remove the module from the 22-pin Molex connector.
Install the LE3/BRIDGE
A Plastic enclosure is included with the LE3/BRIDGE. The enclosure houses the Bridge module and must be mounted
externally from the LC3000 Reader. Placement of the enclosure should meet the following criteria:
Centrally locate to minimize distance to any laundry machine.
Mount on ceiling, or elevated location to increase range.
Avoid locations near metal objects.
Avoid having obstructions between the LE3/BRIDGE and laundry machines.
FIGURE 20: Bridge Connections
Configuration port
Terminate Bridge
patch cable
(Bridge(s)
and LWIs)
WIRELESS LAUNDRY MACHINE INTERFACE INSTALLATION
LC3000 Laundry Center Installation 18
WIRELESS LAUNDRY MACHINE INTERFACE INSTALLATION
September 27, 2007
1Select the appropriate hardware and mount the LE3/BRIDGE
enclosure.
2Install 1/2” PVC conduit from the LC3000 to the enclosure.
3The LE3/BRIDGE includes two configuration cables (p/n 044-042-
043). This cable has an RJ-45 connector and a 22-pin Molex
connector. Plug the 22-pin connector into the Bridge module.
4A patch cable is required to span the distance between the LE3/
BRIDGE enclosure and the LC3000 Reader. Pull the Patch cable
through the conduit. Install the RJ-45 inline coupler between the
patch cable and the configuration cable. Install the opposite end of
the patch cable into the jack labeled BRIDGE RS-485 of the LC3000 Reader.
5Place the Bridge module into the enclosure.
6Verify communication between the Bridge module and LC3000 Reader using the status LED. The LED should be
blinking approximately once every second. Install the cover onto the plastic enclosure to enclose the cable and
module.
Note: The wire antenna must be slightly arced when the cover is installed.
Laundry Wireless Interface Module (LWI) Installation
Configure the LWI Module
Before installing an LWI module in a washer or dryer, the module must be configured. Configuring consists of assigning
a network ID and machine ID. These two parameters make each LWI module unique within the wireless network,
ensuring only a single module responds to a command from the Bridge.
The network ID can be assigned the values 1 through 7. This number must be identical to the number assigned to the
Bridge. This value sychronizes the communication between the Bridge and the LWI module by selecting the
appropriate frequency hopping table.
The machine ID can be assigned the values 1 through 60. This number corresponds to the unique number assigned to
each washer/dryer located in the Laundry Center. Each washer and dryer must be labeled with the machine number.
The number should be clearly visible to patrons using the Laundry Center.
For Stack Dryers, a single module is used to support both upper and lower machines. The top machine must be
assigned the odd number, the lower machine the even number. The even number must always be 1 more than the
odd number. Thus valid pairs are (1, 2), (3, 4) and (29, 30) and so forth. An invalid combination would be (28, 29).
This would be considered as separate machines at the host software level. The assignment of the top machine
being an odd number is the result of the electrical connection between the wiring harness and module.
It is imperative the LWI module, once programmed with the machine ID, be installed in the corresponding labeled
laundry machine. A label is provided on the side of the module, to allow the installer to write the machine ID
programmed into the module.
1Apply power the LC3000 Reader and make sure it is online.
2Install the configuration cable (p/n 044-042-043) into the RJ-12 jack labeled LWI CONFIG.
This cable is supplied with the LE3/BRIDGE.
FIGURE 21: Wireless Bridge
WIRELESS LAUNDRY MACHINE INTERFACE INSTALLATION
LC3000 Laundry Center Installation 19
WIRELESS LAUNDRY MACHINE INTERFACE INSTALLATION
September 27, 2007
3Plug the 22-pin connector into the mating connector of the LWI module.
The LC3000 Reader will detect the LWI module. The top two lines of the display show the machine ID, software
version and network ID. The factory default for the network ID and machine ID is FF. If the LWI module has
previously been assigned, the message Already Assigned is displayed. In all cases, enter 1 for yes, to reassign
the network ID and/or machine ID.
4Set the Network ID.
Valid values are 1 through 7. This value must match the network ID selected for the Bridge.
5Set the machine ID.
Valid Values are 1 through 60.
It is imperative the LWI module, once programmed with the machine ID, be installed in the corresponding labeled
laundry machine. A label is provided on the side of the module, to allow the installer to write the machine ID
programmed into the module.
6When programming has been completed, disconnect the LWI module from the configuration cable.
The steps listed above must be repeated for each LWI module to be installed in the Laundry Center. When
programming the machine ID, the values should be written on the label provided to ensure it is installed in
the correct washer or dryer.
Install the LWI Module
To install an LWI module, either the hood or front panel of the laundry machine will have to be removed to gain access
to the electronic control board. Consult the manufacturer’s manual for steps to perform this task. Each LWI30xx
contains a wiring harness for connecting the LWI module to the laundry machine’s control board. All wiring harnesses
support both single and stacked machines. If installing in a single machine, some connectors may not be used.
In a typical installation, the LWI module can be installed inside the laundry machine. However, if a laundry machine is
more then 75 feet from the LE3/BRIDGE, it may be necessary to mount the module on the outside of the laundry
machine for best reception. Sheet metal screws are provided with the module.
Install the LWI3010 Module for Maytag laundry machines
Maytag laundry machines require an LWI3010 module. A single LWI3010 will support both
single washer/dryer machines and stacked dryer machines.
Disconnect all power to the machines.
1Remove the operator console (with display and switches) from the machine.
Single machine: remove only the top two screws.
Stacked machine: remove only the lower two screws on the top panel.
2With access to the machine’s control board, Install the six-pin connector of the wiring
harness into the (AA3) connector of the laundry machine’s control board.
Stacked machines: Install the 2-pin connector on the wiring harness into the (AA2) connector of the control board.
3Install the 22-pin connector of the wiring harness into the LWI3010 wireless module.
4Mount the wireless module inside the hood compartment using the double-sticky tape provided, or install the
module on the outside of the machine using the sheet metal screws.
E 22: LWI wireless module
WIRELESS LAUNDRY MACHINE INTERFACE INSTALLATION
LC3000 Laundry Center Installation 20
WIRELESS LAUNDRY MACHINE INTERFACE INSTALLATION
September 27, 2007
If installing inside the hood compartment, keep the module away from the control board and any potential
electrical interference sources.
5Use the wire ties and wire tie blocks included with the LWI3010 to dress the wires within the compartment.
6Re-install the operator console on the machine.
Install the LWI3020 Module for Alliance/Speed Queen laundry machines
Alliance/Speed Queen laundry machines require an LWI3020 module. A single LWI3020 will support both single
washer/dryer machines and stacked dryer machines.
Before installing an LWI3020, verify that the transformer in the machine is the correct type. The
transformer should have 4 Red wires on the secondary side. If there are only 2 wires, then the transformer
must be replaced. The correct transformer is (p/n 201375P), and can be ordered from Alliance Laundry
Systems through your laundry supplier.
Disconnect all power to the machines.
1Remove the operator console (with display and switches) from the machine.
Single machine: remove only the top two screws.
2With access to the machine’s control board, install the 4-pin connector of the wiring harness labeled P1 onto the
(H5) connector of the laundry machine’s control board.
The H5 connector may be either 4 or 7 pin. If the connector has 7 pins, the P1 connector must be installed on pins
1 through 4.
When installing the LWI3020 onto a stacked machine, the P2 connector must be installed into the control
board of the even numbered machine. For example, if the stacked machine will be assigned machines 3
and 4 within the laundry center, then the P1 connector would be installed in the control board identified as
machine 3 and the P2 connector must be installed in the control board of the machine identified as
machine 4.
LWI
wireless module
FIGURE 23: LWI3010 installation in Maytag laundry machine
AA3
AA2
Stacked machine only
WIRELESS LAUNDRY MACHINE INTERFACE INSTALLATION
LC3000 Laundry Center Installation 21
WIRELESS LAUNDRY MACHINE INTERFACE INSTALLATION
September 27, 2007
3Install the two Molex pins connected to the Orange and Blue wires on the wiring harness into the two open
positions of the transformer’s secondary output connector.
This is an AC output, so the pins are interchangeable.
4Install the 22-pin connector of the wiring harness onto the LWI3020 wireless module.
5Mount the wireless module inside the console compartment using the double-sticky tape provided, or install the
module on the outside of the machine using the sheet metal screws.
If installing inside the hood compartment, keep the module away from the control board and any potential
electrical interferences.
6Use the wire ties and wire tie blocks included with the LWI3020 to dress the wires within the compartment.
7Re-install the operator console on the machine.
FIGURE 24: LWI3020 installation in Speed Queen/Alliance laundry machine
Transformer
LWI
wireless module
“Even Numbered Machine” for stacked machine only
Red
Red
Controller Board
(Odd or only)
Controller Board
(Even)
4 wires indicates
dual secondary output
APPENDIX
LC3000 Laundry Center Installation 22
APPENDIX
September 27, 2007
APPENDIX
FEATURES
Interfaces to: Maytag commercial “debit-card” ready, Speed Queen NetMaster and MDC, and Whirlpool Advantech
laundry machines
TCP/IP and wireless protocols encrypted using AES
Configuration via keypad/display, CONFIG port or telnet
Keypad (Service Card) configuration can be disabled
Telnet access can be disabled
Stores up to 40,000 transactions offline
Displays balance, account warnings and other messages following transactions
Adjustable volume setting
Graphics display supports 8 lines X 21 characters text
Backlight display
Contains a keyed lock to secure the inside of the unit, along with a hinged door to access the circuit boards
High security lock and keys can be purchased:Medeco 60W-0750-239 from RA-LOCK Company (800-777-6310).
Supports 10/100Base-T or RS-485 communication
Supports wired or 2.46Hz wireless communication to laundry machines
Compatible with BbTS Universal and Unix Editions
Reader supports up to 60 laundry machines
Software downloads remotely
TRANSACTION PROCESS
LC3000 Laundry Center Installation 23
TRANSACTION PROCESS
September 27, 2007
TRANSACTION PROCESS
The LC3000 Laundry Reader displays cardholder instructions. When idle, the
reader display toggles between instructions and machines available.
Offline messages are only displayed if offline operations are allowed in
the reader configuration at the host and card number is valid.
Transaction Process
1Select a machine by using the Reader’s numeric keypad, and press Enter.
The machine’s status displays:
• Available
Out of Service (machine not configured)
Machine # Invalid (machine # greater than 60)
2Swipe a card within 10 seconds.
Otherwise, the transaction is aborted.
3The transaction is deducted from the cardholder account.
The reader displays instructions to load clothes and start machine.
If the machine is not started, refunds do not occur automatically.
Cancel Transaction: Press the Cancel button before swiping card.
Add Dry Time
Additional dry time may be added before or during dry cycle.
1Select a machine by using the Reader’s numeric keypad, and press Enter.
The machine number, Total Cost (the amount that will be charged for the
original cycle plus any additional cycles), and cost of an additional cycle is
displayed.
2Press the Add Time softkey to display the cost and time (in minutes) of an
additional cycle.
Pressing Add Time again multiplies the additional dry time and increases
the Total Cost to reflect the Total Transaction amount.
3Swipe a card within 10 seconds.
The reader displays instructions to load clothes and start machine.
‘*” indicates the reader is offline
The next character:
E - empty, no stored transactions
1 - less than 11% full
2 - less than 22% full
.
.
9 - less than 99% full
F - full
MANAGER MENUS
LC3000 Laundry Center Installation 24
MANAGER MENUS
September 27, 2007
MANAGER MENUS
The Manager Card is used to access LC3000 Laundry Reader menus for sales data and modifying reader settings.
Manager Menus
FIGURE 25: Manager Menus
Bridge Status
Display Message Description
Not Defined This Bridge is not configured by the LWI CONFIG port.
No Bridge Comm This Bridge is configured, but is not successfully communicating with the BRIDGE RS-485 port.
No LWIs Defined This Bridge is successfully communicating with the BRIDGE RS-485 port, but no LWIs are defined for this Bridge.
No LWI Communication One or more LWIs are defined for this Bridge, but no LWI communication exists.
LWI Communication OK One or more LWIs are configured for this Bridge and all are successfully communicating with the Bridge.
LWI Communication One or more LWIs are configured for this Bridge, but some are not successfully communicating with the Bridge.
Swipe
Manager Card
1. Sales Totals
2. Terminal Setup
3. Machine Service
4. Bridge Status
5. LCM20 Status
Sales Total
Card Interval $
Card Interval #
Card Total $
Card Total #
Terminal Setup
Display Backlight (Off, Low, Medium, High)
Display Contrast (Decrease, Increase)
Volume Setup (Decrease, Increase)
Machine Service
1. Set In/Out of Service (1-60)
2. View Out of Service
Bridge Status
# (1-7) status (see table)
LCM20 Status
____ ____ ____ (LCM20 addresses: 0, 1, 2)
A = machines configured and communicating
I = machines configured and not communicating
- = machines not configured
Status Key:
LAUNDRY COMPONENTS DIMENSIONS AND WEIGHT
LC3000 Laundry Center Installation 25
LAUNDRY COMPONENTS DIMENSIONS AND WEIGHT
September 27, 2007
LAUNDRY COMPONENTS DIMENSIONS AND WEIGHT
LC3000: 9.6" H x 7.92'' W x 3.3" D, 7.6 lbs.
LE3/PSENCL: 9.6" H x 7.92" W x 3.3" D, 7.6 lbs.
LE3/BRIDGE: 4.5" H x 4.5" W x 2" D, 1.0 lb.
LWI30XX: 3" H x 3" W X 1.5" D, 1.0 lb.
FIGURE 26: LC3000 Dimensions
7.220''
6.270''
0.720''
8.940''
0.940''
0.000''
8.840''
0.000''
ACMAIN
Mount
Mount
Mount Mount
9.660''
3.360''
6.360''
1.200
4.200
7.920''
LAUNDRY COMPONENTS DIMENSIONS AND WEIGHT
LC3000 Laundry Center Installation 26
LAUNDRY COMPONENTS DIMENSIONS AND WEIGHT
September 27, 2007
Lithium Battery: There is a fire risk if the battery is replaced with an incorrect type.
Proper disposal of a used battery is essential. Please follow the manufacturer’s instructions.
Power Supply: Replacing the power supply, if necessary, is simplified with a
magnetic or clip screwdriver, such as the Craftsman No. 1 x 4 inch screwdriver
shown. (Sears, item #00941362000, model #41362.
LC3000 Component Specifications
LC3000
Power Input Voltage Range
Input Frequency
Input Current
120VAC
60Hz
1.4A, max
Operating Environment Temperature
Relative Humidity
Altitude
0 to +45C (+32 to +114F)
0 to 95 percent, non-condensing
0 -10,000 feet
Non-Operating
Environment
Temperature
Relative Humidity
Altitude
-20 to +70 C (-4 to +158F)
0 to 95 percent, non-condensing
0 - 35,000 feet
LE3/PSENCL
with LCM20
Power Input Voltage Range
Input Frequency
Input Current
120VAC
60Hz
1.4A, max
Operating Environment Temperature
Relative Humidity
Altitude
0 to +45C (+32 to +114F)
0 to 95 percent, non-condensing
0 -10,000 feet
Non-Operating
Environment
Temperature
Relative Humidity
Altitude
-20 to +70 C (-4 to +158F)
0 to 95 percent, non-condensing
0 - 35,000 feet
LE3/BRIDGE
Power Input Voltage Range
Input Frequency
Input Current
9 to 30 VAC or 7 to 36 VDC
60Hz
0.12A, max
Operating Environment Temperature
Relative Humidity
Altitude
0 to +45C (+32 to +114F)
0 to 95 percent, non-condensing
0 -10,000 feet
Non-Operating
Environment
Temperature
Relative Humidity
Altitude
-20 to +70 C (-4 to +158F)
0 to 95 percent, non-condensing
0 - 35,000 feet
LWI3xxx
Power Input Voltage Range
Input Frequency
Input Current
9 to 30 VAC or 7 to 36 VDC
60Hz
0.12A, max
Operating Environment Temperature
Relative Humidity
Altitude
0 to +45C (+32 to +114F)
0 to 95 percent, non-condensing
0 -10,000 feet
Non-Operating
Environment
Temperature
Relative Humidity
Altitude
-20 to +70 C (-4 to +158F)
0 to 95 percent, non-condensing
0 - 35,000 feet
LC3000 LAUNDRY READER DEFAULT CONFIGURATION SETTINGS
LC3000 Laundry Center Installation 27
LC3000 LAUNDRY READER DEFAULT CONFIGURATION SETTINGS
September 27, 2007
LC3000 LAUNDRY READER DEFAULT CONFIGURATION SETTINGS
The LC3000 Laundry Reader’s default settings are:
DHCP enabled
NP (host) IP address assigned by DHCP server
Restore Default Settings
Forget your password? Restore Default Settings.
1Connect a cable from a computer’s serial port to the one labelled “RS-232 CONFIG”.
Cable connections are shown in RS-232 Config Port Connections (page 8).
2Open a terminal program (such as Hyperterminal) and establish connection settings:
9600 baud
•1 stop
no parity
no flow control
3Type xxx within 3 seconds after “Config Task Started” is displayed in the terminal program.
“Restoring to Factory Defaults will display during reset.
4Disconnect cable from RS-232 CONFIG.
MW9010/MW9012 LAUNDRY READER RETROFIT
LC3000 Laundry Center Installation 28
MW9010/MW9012 LAUNDRY READER RETROFIT
September 27, 2007
MW9010/MW9012 LAUNDRY READER RETROFIT
BbTS Unix laundry centers with existing MW9010/MW9012 Laundry Readers can upgrade to the LC3000 Laundry
Reader. Upgrading the Reader does not require wiring, LCM2s or laundry machine interface replacements.
The LC3000, as shipped from Blackboard, is configured for up to 60 machines on up to 3 LCM20s. Once the LC3000 is
mounted and connected to the existing system, configure the LC3000 to communicate with existing LCM2s and
existing interfaces.
The LC3000 communicates with 60 laundry machines.
Configure LC3000 for retrofit (wired laundry centers only)
1Connect to the LC3000 using a RS-232 connection or Telnet.
2Login using the default password: IPrdr4U.
3At the prompt, type:
machine alllcm2
This configures the Reader to communicate with all connected laundry machines using the LCM2 interface.
4Type “machines” to list the machine interfaces for all 60 machines.
Machine interface configurations are not affected by resetting Reader to the default configuration or other
configuration commands.

Navigation menu