Transtek Medical Electronics LS502-E01 DATA BRIDGE User Manual
Guangdong Transtek Medical Electronics Co.,Ltd DATA BRIDGE Users Manual
USERS MANUAL
LS901-E Product structure Power Adaptor Socket Broadband Interface LAN Light Reset Button WAN Light Power Adaptor Internet Cable Before using 1 Open Broadband Service Open standard broadband service,such as telecommunication, Great Wall, Unicom, Railcom 2 Environmental Requirements of Area Network PC automatically connect to the network via router, User can enter into base station installation steps directly. PC not connect to the network via router, User can buy a router, refer to the user manual to set up the router to autodial and connect to the network. Unable to distinguish whether PC connect to the network via router. 1) Turn on PC, if PC automatically connect to the network, which indicates PC automatically connect to the network via router.(Please refer to 2) Turn on PC, if PC need to autodial to connect to the network, which indicates PC not connect to the network via router. (Please refer to (Everytime connecting the network, if the screen display dail-up interface, which indicates PC not connect to the network via router) Install data bridge 1 Use power adaptor to connect power source and bridge. 2 Use internet cable to connect bridge with LAN interface of the router. 3 When WAN and LAN light on the bridge turns green, which indicates the connection is successful. Caution To prevent the product hurting people during using and prolong product lifetime, please follow below rules. Symbol Meaning Regular instruction Forbidden Disassemble forbidden About battery use Avoid the water, dust and others on the adapter. When the surface of the adapter is broken, please do not use it. Please do not disassemble or repair the adapter without professional instruction. Product instruction Please keep your hands dry to install the data bridge. Data bridge will cache data due to network problem. 1 Using the wet clothing to remove the dirt on the product. Please turn off the power and network during a lightning storm. Data bridge only applies to Lifesense dedicated power adaptor, please don’t use other type. For unprofessional person, please don’t teardown it alone. About product daily maintenance Please put the data bridge at cool and dry place. Please don’t immerse in water or liquid. Please do not disassemble the products without professional people ‘s instruction. 2 Please put liquid soap on the cloth, and wring out it to wipe out the dirt on the surface, at the end pls use dry cloth to wipe. Trouble shooting Symptom Advanced setting Fault cause Solution (Attention: only for user whose DHCP function on router wasn’t open) Please check the power connecting situation of the data bridge Turn on power, LAN and WAN light is dark Power connecting error Turn on power, LAN and WAN light is shining Data bridge connect to the router is abnormal LAN lights up, WAN is shining PC can enter the internet 1) If DHCP function on router was open, press But bridge can’t enter reset button for a moment on bridge to make it the internet reset to factory defaults 2) If DHCP function on router wasn’t open, pls refer to IP setting up method on bridge (page 5) LAN and WAN light turns green, data was sucessfully sent from device, but not shown in health center Not choose user for the device Please add user in device management interface Data can’t automatically distinguish the user Please go to get the data from device management interface 1) Please check the power connecting situation of the router 2) Please check the connecting situation between bridge and router 1 Press reset button, and hold it more than 5 seconds LAN and WAN light shining at the same time, pls loose the button. 2 Connect bridge to PC by internet cable directly 3 Setting up the network on PC and save, pls refer to below image: 5 If setting up is successful, below interface will shown. 6 If setting up is fail, below interface will shown: 4 Open IE browser, put http://192.168.1.2/ into the address column, enter into the address, below interface will shown. If choose automatically get IP address, for DNS address we can choose automatically or manually put in. If choose manually put in IP address, for DNS address we have to manually put in accordingly. Bridge will reset and run automatically, setting begin to take effect. Please try to set again. Specifications Solution Product name Product dimension Product Weight Display Internet cable Power Parameter Normal working condition Temperature: LS901-E Storage & transportation condition Temperature: 100 x 58 x 24mm Working atmospheric pressure 80kPa ~ 105kPa 62g Storage & transportation atmospheric pressure 80kPa ~ 105kPa 2 green LED light 1m, with RJ45 socket DC 5.0V RF distance ≤30m Match distance ≤1m Humidity: Humidity: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If 14 this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. 15
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 5.0-c060 61.134777, 2010/02/12-17:32:00 Format : application/pdf Title : LS901数据基站说明书 Metadata Date : 2012:11:01 16:57:38+08:00 Modify Date : 2012:11:01 16:57:38+08:00 Create Date : 2012:02:27 15:13:15+08:00 Creator Tool : Adobe Illustrator CS5 Thumbnail Width : 256 Thumbnail Height : 116 Thumbnail Format : JPEG Thumbnail Image : (Binary data 6167 bytes, use -b option to extract) Instance ID : uuid:0fd0fe31-3f37-485d-be81-501a83cbdcc3 Document ID : xmp.did:C6FB9A841261E111A6CDBFCB44020BE3 Original Document ID : uuid:5D20892493BFDB11914A8590D31508C8 Rendition Class : proof:pdf Derived From Instance ID : uuid:33bfc20b-bfe9-474b-b7c3-7649bc611fb2 Derived From Document ID : xmp.did:9B903A1F71F5E011A3A4F28642ED2159 Derived From Original Document ID: uuid:5D20892493BFDB11914A8590D31508C8 Derived From Rendition Class : proof:pdf History Action : saved, saved, saved History Instance ID : xmp.iid:A68FDD704EF5E0119EE0F5B0C25D2A92, xmp.iid:9B903A1F71F5E011A3A4F28642ED2159, xmp.iid:C6FB9A841261E111A6CDBFCB44020BE3 History When : 2011:10:13 15:22:11+08:00, 2011:10:13 15:58:22+08:00, 2012:02:27 15:13:15+08:00 History Software Agent : Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5 History Changed : /, /, / Manifest Link Form : EmbedByReference Manifest Reference File Path : C:\Documents and Settings\Administrator\桌面\说明书正稿文件10.11\LS901\拨号连接.jpg Startup Profile : Print Has Visible Overprint : False Has Visible Transparency : False N Pages : 1 Max Page Size W : 200.000368 Max Page Size H : 60.000472 Max Page Size Unit : Millimeters Font Name : ArialMT, FZLTHJW--GB1-0, SimHei Font Family : Arial, 方正兰亭黑简体, 黑体 Font Face : Regular, Regular, Regular Font Type : Open Type, TrueType, TrueType Font Version : Version 3.00, 1.00, Version 3.02 Font Composite : False, False, False Font File Name : ARIAL.TTF, 兰亭黑简.TTF, simhei.ttf Plate Names : Cyan, Magenta, Yellow, Black Swatch Groups Group Name : 鲜艳 Swatch Groups Group Type : 1 Swatch Groups Colorants Swatch Name: C=60 M=90 Y=0 K=0 Swatch Groups Colorants Mode : CMYK Swatch Groups Colorants Type : PROCESS Swatch Groups Colorants Cyan : 60.000002 Swatch Groups Colorants Magenta : 90.000004 Swatch Groups Colorants Yellow : 0.003099 Swatch Groups Colorants Black : 0.003099 Producer : Adobe PDF library 9.90 Page Count : 9 Creator : Adobe Illustrator(R) 15.0 For : Ʒ, Bounding Box : -1 -1067 2429 20 Container Version : 11 Creator Version : 15EXIF Metadata provided by EXIF.tools