Tyco Safety Canada 0010BASET ETHERNET HUB User Manual Installation Instructions

Digital Security Controls Ltd. ETHERNET HUB Installation Instructions

Installation Instructions

Download: Tyco Safety Canada 0010BASET ETHERNET HUB User Manual Installation Instructions
Mirror Download [FCC.gov]Tyco Safety Canada 0010BASET ETHERNET HUB User Manual Installation Instructions
Document ID104339
Application ID1lLGMfoMxwAOwy1vd9uNxQ==
Document DescriptionInstallation Instructions
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatMicrosoft Word - pdf
Filesize19.74kB (246785 bits)
Date Submitted2000-06-12 00:00:00
Date Available2000-06-23 00:00:00
Creation Date2000-06-12 14:58:54
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2000-06-12 14:58:56
Document TitleInstallation Instructions

Four Channel 10BaseT Ethernet Hub Installation Instructions
Brian Wauchope
04/25/00
Specifications:
Compliant with IEEE 802.3 specifications.
Standby current draw = 96mA
Maximum current draw = 330mA
Input voltage range = 8 to 15VDC
Maximum Bandwidth = 10MB/s
Mounting Instructions:
1.
2.
3.
Locate a suitable mounting location for the Ethernet Hub module inside the cabinet.
Align the two mounting tabs with the holes located in the bottom of the wire raceway and insert.
Snap the module into place by pushing the opposite side towards the back of the cabinet.
Module
Cabinet
Tabs
Wiring Instructions:
1. Home-run CAT-5 cable to each desired location throughout the dwelling and route into the cabinet.
2. Connect each CAT-5 drop to a port on the Ethernet Hub marked ‘Port 1’, ‘Port 2’, ‘Port 3’ or ‘Port 4’.
3. Locate a suitable 110VAC receptacle for placement of the wall-mount transformer.
4. Route the output cord from the wall-mount transformer (supplied) into the cabinet and plug into the
Ethernet Hub ‘PWR-IN’ jack.
5. Apply power to the wall-mount transformer.
Important: All requirements for Installation of CAT 5 should be met for proper operation of connected
equipment.
Some require ments of CAT-5:
Do not strip sheathing of cable more then required for proper termination. Do not kink or knot cable. Do
not crush cable with cable ties. Do not bend cable at right angles or sharp bends. All cable bends should
have a minimum of a 2" radius.
NOTE: A minimum of two and a maximum of four computers or peripherals must be connected for proper
operation of the hub. The network connections can be made on any available port on the hub and are not
restricted to certain ports. Also note that the computers and/or peripherals must be configured properly for
peak performance of the hub. Please consult the manual supplied with your operating system software.
LED Indication:
Label
Color
Function
Power
CH-1
Red
Green
Yellow
Green
Yellow
Green
Yellow
Green
Yellow
Red
Yellow
Red
Red
Yellow
Yellow
Yellow
Green
Green
Green
Power presence
Link Status
Collision Detect
Link Status
Collision Detect
Link Status
Collision Detect
Link Status
Collision Detect
Collision
Carrier Sense
>80% Bandwidth Utilization
>64% Bandwidth Utilization
>32% Bandwidth Utilization
>16% Bandwidth Utilization
>8% Bandwidth Utilization
>4% Bandwidth Utilization
>2% Bandwidth Utilization
>1% Bandwidth Utilization
CH-2
CH-3
CH-4
Global Act
Bandwidth Meter
Typical Installation:
9V DC 500mA Adapter
Computer or
Networkable
Peripheral
Computer or
Networkable
Peripheral
CAT 5
Cable
CAT 5
Cable
Computer or
Networkable
Peripheral
Computer or
Networkable
Peripheral

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2000:06:12 14:58:54
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2000:06:12 14:58:56-04:00
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: F530010BASET

Navigation menu