Tyco Safety Canada 09WT5500 Wireless Security System Keypad User Manual

Digital Security Controls Ltd. Wireless Security System Keypad WT5500

a href="https://usermanual.wiki/Tyco-Safety-Canada" itemprop="url"> Tyco Safety Canada >

User Manual

EnglishWARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function, and information on the limitations as to liability of the manufacturer. NOTE: These instructions are to be used in conjunction with the appropriate Control Panel Installation Manual, with which this equipment is intended to be used.WT5500Installation Instructions123456780#9*Enter Code toArm System <>29007335R001
The WT5500 keypad can be used on security systems with up to 64zones. The WT5500 keypad is compatible with the SI9155 system.Specifications• Temperature range: -6°C to +54°C (22°F to 140°F), Temperaturerange for UL/ULC: 0°C to +49°C (32°F to 120°F)• Humidity (MAX): 93%R.H.• Plastic enclosure protection degree: IP30, IK04• Transformer voltage: 4.5V @ 0.5A•Battery: 3V• WT5500 Current draw: 50mA (standby)/125mA (maximum)•Wall mount tamper• 5 programmable function keys• Ready (Green LED), Armed (Red LED), Trouble (Yellow LED), AC (GreenLED)• Frequency: 433.92MHz (WT5500-433 only)• Frequency: 868.35MHz (WT5500-868 only)UnpackingThe WT5500 keypad package is available in five distinct configurations,Standard, Proximity, Complete, Desk Stand, and Proximity Tags Only. Thecontents of each are described below.MountingYou should mount the keypad where it is accessible from designated pointsof entry and exit. Once you have selected a dry and secure location, performthe following steps to mount the keypad.Mounting Plate1. Locate the screw holes (4) at each corner of the mounting plate.2. With the smooth face of the mounting plate facing up, use the four screwsprovided to affix the mounting plate to the wall.3. Align the four mounting slots in the WT5500 housing with the fourmounting tabs protruding from the mounting plate. 4. Slide the unit into place.5. Firmly but carefully snap the unit down onto the mounting plate.Desk Stand1. Place the desk stand on a secure, uncluttered surface.2. Align the four mounting slots in the WT5500 housing with the fourmounting tabs protruding from the desk stand. 3. Slide the unit into place.4. Firmly but carefully snap the unit down onto the desk stand.Apply Battery Power1. Slide the unit up and out from the mounting plate. The bay for the four AAbatteries is open and clearly visible at the back of the unit.2. Insert the batteries as directed on the unit.3. Replace the unit on the mounting plate.Apply AC Power1. Slide the unit up and out from the mounting plate.2. Locate the AC adaptor jack at the back of the unit housing.3. Place the AC adaptor plug in the housing indentation, perpendicular to theunit. Insert the adaptor plug firmly into the jack.4. Pivot the adaptor plug downwards so that it fits flush with the housing.Guide the AC wire along the channel provided in the unit housing; the wireshould finally extend through the bottom of the housing.5. Replace the unit on the mounting plate.6. Plug the AC adaptor into a wall outlet.Programming the KeypadThere are several programming options available for the keypad. These aredescribed below. Programming the keypad is similar to programming therest of the system. To turn an option on or off, press the number correspond-ing to the option on the number pad. The numbers of the options that arecurrently turned on will be displayed along the top of the LCD. For informa-tion on programming the rest of your security system, please refer to yoursystem’s Installation Manual.Broadcasting LCD LabelsAll LCD programming is done using the keypad. If more than one LCD key-pad is present on the system, labels programmed at one keypad can bebroadcast to all other LCD keypads. Perform the following procedure in orderto broadcast labels:1. Program one LCD keypad completely.EnglishInstallation InstructionsWT5500 - STANDARD WT5500P - PROXIMITY•1 WT5500 keypad •1 WT5500P keypad•1 WT5500BRK wall bracket •1 WT5500BRK wall bracket•1 Installation manual •1 Installation manual•1 Inner door sticker •1 Inner door sticker•4 AA batteries •4 AA batteries•1 Hardware pack •1 Hardware pack•1 PT4 (433MHz proximity tag) or PT8 (868MHz proximity tag)WT5500D - COMPLETE WT5500DMK - DESK STAND•1 WT5500 keypad •1 WT5500DMK keypad•1 WT5500X AC transformer •1 WT5500X AC transformer•1 WT5500DMK desk stand •1 Installation manual•1 WT5500BRK wall bracket •1 Hardware pack•1 Installation manual•1 Inner door sticker•4 AA batteries•1 Hardware packPROXIMITY TAGS ONLY•1 PT4 (433MHz proximity tag) or PT8 (868MHz proximity tag)•1 Installation manualScrewHolesScrewHolesMountingTabsScrewHolesScrewHoles9049$$$$$$$$9048MountingHolesMountingHolesBatteriesPlugWireChannelTamperSwitch
2. Enter keypad programming by pressing 4 > 8 > Installer Code > 4. 3. Enter Section 998 at the keypad that was programmed. The keypad will now broadcast the label programming tothe PC9155. The PC9155 will then program the labels in others WT5500 keypads that have been enrolled by wayof the RF link. NOTE: This operation may take several minutes.4. When the keypad is finished press the # key to exit.NOTE: Label broadcast from this keypad is only compatible with other WT5500 keypads.Language Programming Hold the (<>) keys for 2 seconds to enter language programming. Scroll to the desired language and press 4 toselect.NOTE: If Section 077, Option 4 is turned off, language programming can only be performed whilein installers programming.Enrolling the KeypadThe WT5500 must be configured in tandem with the PC9155 in order for the system to function as desired.1. Turn on the PC9155 unit. The panel will be alert to any keypad enrollment activity for a period of two minutes. Notethat the unit’s Ready and AC LEDs will be activated for this two-minute period.2. A WT5500 must be turned on during this two-minute period for it to be assigned to the PC9155. 3. Simultaneously press and hold the * and # keys; by doing so you force the keypad to broadcast its ESN (electronicsecurity number). The keypad will intermittently flash its Ready and AC LEDs (one second on, one second off). Thisindicates that the keypad is in enrollment mode.4. When the keypad has been successfully enrolled - this should take less than 30 seconds -  on the system, the mes-sage ‘Enrollment Successful’ will be displayed on the keypad LCD for five seconds. The Ready and AC LEDs willreturn to their ready state.Any additional keypads to be added to this system can be enrolled in the same manner as described above. The sys-tem will add each keypad to the next available slot, and this slot number will be displayed on the keypad’s LCD dis-play once the keypad has been successfully enrolled.Programming Labels 1. Use this section to assign a meaningful name (e.g. Front Door, Hallway, etc) to each zone.2. Enter keypad programming by pressing 4 > 8 > Installer Code > 4. Enter the 3-digit section number for thelabel to be programmed.3. Use the arrow keys (<>) to move the cursor underneath the letter to be changed. 4. Press the number keys 1 through 9, corresponding to the letter you require. For example, pressing number key 2once will display the letter D; pressing it again will display the letter E; pressing it a third time will display the letterF, and so on.5. When the required letter or number is displayed use the arrow keys (<>) to scroll to the next letter.6. When you are finished programming the Zone Label, press Q. Scroll to ‘Save’ and press Q again.7. Repeat Steps 2 through 5 until all Labels are programmed.ASCII CharactersChanging Brightness/ContrastLCD Keypads1. Press [4][6][Master code].2. Use the arrow keys (<>) to scroll to either Brightness Control or to Contrast Control.3. Press 4 to select the setting you want to adjust.4. a) Brightness Control: There are multiple backlight levels. Use the arrow keys (<>) to scroll to the desired level.5. b) Contrast Control: There are 10 different display contrast levels. Use the arrow keys (<>) to scroll to the desiredcontrast level.6. To exit, press #.Changing the Buzzer LevelLCD Keypads1. Press [4][6][Master Code].2. Use the arrow keys (<>)to scroll to Buzzer Control.3. Use the arrow keys (<>) to scroll to the desired buzzer level among the 21 available selections.4. To exit, press #.Keypad EnrollmentEnter keypad programming by pressing 4 > 8 > Installer’s Code > 000.[0] Partition / Slot Assignment[1]-[5] Function Key Assignment[1] - A, B, C, 1 [4] - J, K, L, 4 [7] - S, T, U, 7 [0] - Space[2] - D, E, F, 2 [5] - M, N, O, 5 [8] - V, W, X, 8[3] - G, H, I, 3 [6] - P, Q, R, 6 [9] - Y, Z, 9,0Digit Option Valid Range Default1st Partition Assignment (0=Global Keypad) 0 to 8 1 I_____I2nd Slot Assignment 1 to 8 LED,ICON=1/LCD=8 I_____IFunction Key Button Valid RangeDefault Function[1] Function Key 1 Assignment 00 to 32 03 Stay Arm I_____I_____I[2] Function Key 2 Assignment 00 to 32 04 Away Arm I_____I_____I[3] Function Key 3 Assignment 00 to 32 06 Chime On/Off I_____I_____I[4] Function Key 4 Assignment 00 to 32 14 Bypass I_____I_____I
Download:
Mirror Download [FCC.gov]
Document ID1055096
Application IDKUfRIXRkDjNeuILcsF+foA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize122.31kB (1528923 bits)
Date Submitted2009-01-12 00:00:00
Date Available2009-01-12 00:00:00
Creation Date2008-11-21 16:18:49
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2008-11-28 18:28:59
Document TitleWT5500.fm
Document CreatorPScript5.dll Version 5.2
Document Author: tvecchiarelli
FCC ID Filing: F5309WT5500

Navigation menu