Tyco Safety Canada 15TL2553GRE Cellular alarm communicator with 2G/3G wireless module User Manual My
Digital Security Controls Ltd. Cellular alarm communicator with 2G/3G wireless module My
User Manual
3G2055(R)-E HSPA/3G Wireless Alarm Communicator SCW 3G Communcator - North America TL2553G(R)-E Ethernet/Internet and HSPA/3G Dual-Path Alarm Communicator SCW 3G/Ethernet Communicator - North America Installation Manual v5.0 Warning: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. WARNING: Installer please read carefully General Information Keypad Data Display Entering Data From Keypad Entering ASCII Characters Mounting Considerations Communicator Technical Specifications General Information Features UL/ULC Installation Requirements Communicator Frequency Bands for North America Ratings Hardware Compatibility Software Compatability Communicator Pre Intsallation Configuration Connect24™1 Account and SIM card Activation Encryption Communicator Configuration with SCW Installation Location Installing CAT 5 Cable (TL2553G(R)-E only) INSERTING/REMOVING THE SIM CARD Communicator Reset Establishing a Communication Channel with the SCW Panel. Initial Programming of Communicator and SCW SMS Command and Control Functions Label Programming for SMS Message Communicator Placement Test Ethernet/Cellular Programming Options System Options Programming Options Communications Reporting Codes System Test Options [026 - 029] Ethernet Receiver 1 Options Ethernet Receiver 2 Options Ethernet Options Cellular Receiver 1 Options Cellular Receiver 2 Options Cellular Options Command and Control Options SMS Command and Control Functions SMS Command and Control Response Receiver Diagnostic Testing System Information (Read Only) System Reset Defaults Communicator Troubleshooting Communicator Troubleshooting Ethernet Cellular Programming Worksheets System Options Programming Options 10 10 10 11 11 11 12 12 12 14 16 17 18 19 19 20 20 21 22 22 23 25 25 26 26 28 30 30 30 System Test Options Ethernet Receiver 1 Options Ethernet Receiver 2 Options Ethernet Options Cellular Receiver 1 Options Cellular Receiver 2 Options Cellular Options Command and Control Options Receiver Diagnostic Testing System Information (Read Only) Limited Warranty System Reset Defaults EULA Regulatory Information 30 31 31 31 31 31 32 32 33 33 34 34 34 35 Passive infrared motion detectors operate by sensing changes in temperature. However their effectiveness can be reduced when the ambient temperature risesnear or above bodytemperature or if there are intentionalor unintentional sourcesof heat in or near the detection area. Some of these heat sources could be heaters, radiators, stoves, barbecues, fireplaces, sunlight, steamvents, lighting and so on. WARNING: Installer please read carefully Note to Installers The warningson thispage contain vitalinformation. Asthe only individualin contact with system users, it is the installer’s responsibility to bring each item in this warning to the attention of allusersof thissystem. Power Failure Control units, intrusion detectors, smoke detectors and many other security devicesrequire an adequate power supplyfor proper operation. If a device operatesfrombatteries, it ispossible for the batteriesto fail. Even if the batteries have not failed, they must be charged, in good condition and installed correctly. If a device operates only by AC power, any interruption, however brief, will render that device inoperative while it doesnot have power. Power interruptionsof any length are often accompanied by voltage fluctuationswhich may damage electronic equipment such as a security system. After a power interruption has occurred, immediatelyconduct a complete systemtest to ensure that the system operatesasintended. System Failures Thissystemhasbeen carefullydesigned to be aseffective aspossible. There are circumstances, however, involving fire, burglary, or other types of emergencies where it may not provide protection. Any alarmsystem of anytype may be compromised deliberatelyor mayfailto operate as expected for a varietyof reasons. Some, but not all, of the reasonsmaybe: Access by Intruders Intrudersmayenter through an unprotected accesspoint, circumvent a sensing device, evade detection by moving through an area of insufficient coverage, disconnect a warning device, or interfere with or prevent the proper operation of the system. Security and Insurance Regardlessof itscapabilities, an alarmsystemisnot a substitute for propertyor life insurance. An alarmsystemalso isnot a substitute for propertyowners, renters, or other occupantsto act prudentlyto prevent or minimize the harmful effectsof an emergencysituation. Component Failure Although everyeffort has been made to make thissystem asreliable as possible, the systemmayfailto function asintended due to the failure of a component. Smoke Detectors Smoke detectorsthat are a part of thissystemmaynot properlyalert occupants of a fire for a number of reasons, some of which follow. The smoke detectors may have been improperlyinstalled or positioned. Smoke maynot be able to reach the smoke detectors, such aswhen the fire is in a chimney, walls or roofs, or on the other side of closed doors. Smoke detectorsmay not detect smoke from fires on another levelof the residence or building. Everyfire isdifferent in the amount of smoke produced and the rate of burning. Smoke detectorscannot sense alltypesof firesequallywell. Smoke detectorsmay not provide timelywarning of fires caused bycarelessnessor safetyhazards such as smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches, or arson. Even if the smoke detector operates as intended, there may be circumstances when there isinsufficient warning to allow alloccupantsto escape in time to avoid injuryor death. Compromise of Radio Frequency (Wireless) Devices Signalsmay not reach the receiver under all circumstances which could include metalobjectsplaced on or near the radio path or deliberate jamming or other inadvertent radio signalinterference. Criminal Knowledge Thissystem contains security features which were known to be effective at the time of manufacture. It is possible for personswith criminalintent to develop techniqueswhich reduce the effectivenessof these features. It isimportant that your securitysystembe reviewed periodicallyto ensure that its featuresremain effective and that it isupdated or replaced if it isfound that it does not provide the protection expected. Failure of Replaceable Batteries Thissystem’s wirelesstransmitters have been designed to provide several years of battery life under normal conditions. The expected battery life isa function of the device environment, usage, and type. Ambient conditionssuch ashigh humidity, high or low temperatures, or large temperature fluctuations may reduce the expected battery life. While each transmitting device has a low battery monitor which identifies when the batteries need to be replaced, this monitor may fail to operate as expected. Regular testing and maintenance willkeep the system in good operating condition. Telephone Lines If telephone lines are used to transmit alarms, theymay be out of service or busy for certain periodsof time. Also an intruder maycut the telephone line or defeat its operation bymore sophisticated meanswhich maybe difficult to detect. Warning Devices Warning devices such as sirens, bells, horns, or strobesmay not warn people or waken someone sleeping if there isan intervening wallor door. If warning devices are located on a different levelof the residence or premise, then it islesslikely that the occupants will be alerted or awakened. Audible warning devices may be interfered with byother noise sourcessuch asstereos, radios, televisions, air conditioners, other appliances, or passing traffic. Audible warning devices, however loud, maynot be heard bya hearing-impaired person. Inadequate Installation A security system must be installed properly in order to provide adequate protection. Every installation should be evaluated by a security professional to ensure that allaccess points and areas are covered. Locks and latches on windows and doors must be secure and operate as intended. Windows, doors, walls, ceilingsand other building materialsmust be of sufficient strength and construction to provide the levelof protection expected. Areevaluation must be done during and after any construction activity. An evaluation bythe fire and/or police department ishighlyrecommended if thisservice isavailable. Inadequate Testing Most problems that would prevent an alarm systemfrom operating as intended can be found byregular testing and maintenance. The complete system should be tested weeklyand immediatelyafter a break-in, an attempted break-in, a fire, a storm, an earthquake, an accident, or any kind of construction activityinside or outside the premises. The testing should include all sensing devices, keypads, consoles, alarm indicating devices, and any other operational devices that are part of the system. Insufficient Time There may be circumstanceswhen the systemwill operate asintended, yet the occupants will not be protected from an emergency due to their inability to respond to the warnings in a timelymanner. If the systemis remotely monitored, the response maynot occur in time to protect the occupantsor their belongings. Motion Detectors Motion detectorscan onlydetect motion within the designated areasasshown in their respective installation instructions. They cannot discriminate between intruders and intended occupants. Motion detectors do not provide volumetric area protection. Theyhave multiple beams of detection and motion can only be detected in unobstructed areas covered by these beams. They cannot detect motion which occurs behind walls, ceilings, floor, closed doors, glass partitions, glass doors or windows. Any type of tampering whether intentional or unintentionalsuch asmasking, painting, or spraying of anymaterialon the lenses, mirrors, windows or any other part of the detection system will impair its proper operation. General Information Domain Name Service (DNS) programming is not permitted in UL/ULC listed systems Keypad Data Display Section-Toggle Options: The number is displayed when Toggle is ON. The number is not displayed when Toggle is OFF. (e.g., Toggle Options displays: “[--3--6--]”. Options 3 and 6 are ON, all others are OFF). Pressing keys 1 through 8 will alternately turn the Toggle ON and OFF. HEX/Decimal Data: Values that are provided with two defaults, separated by a / character, use the format: hexadecimal followed by decimal equivalent (e.g., Default [0BF5/3061]). Hexadecimal numbers are shown, with all leading zeroes, to the full field length defined for the number. Entering Data From Keypad To enter data at the keypad, press the number key, from the table below, to select the character that you want. Pressing the number key repeatedly will scroll through the characters available for that key. Press the [*] key and use [<] [>] keys to scroll to one of the following selections: (Press [*] to select the Option.) ASCII Entry. Use this mode to enter ASCII characters from the keypad. Clear to End. This selection will clear the remainder of the display. Clear Display.This selection will completely erase all entries on the display. Change Case. Toggles between upper/lower case depending on current selection. NOTE: The “0” on the keypad is used to delete characters. Table 1: Data Entry at Keypad Key Value Key Value Key Value 1 1-A-B-C 4 4-J-K-L 7 7-S-T-U 2 2-D-E-F 5 5-M-N-O 8 8-V-W-X 3 3-G-H-I 6 6-P-Q-R 9 9-Y-Z-0 Entering ASCII Characters To enter American Standard Code for Information Interchange (ASCII) characters at the keypad, perform the following: 1. Press [*] and use [<] [>] keys to scroll to “ASCII Entry”. 2. Press [*] to select ASCII entry mode. 3. Use the [<] [>] keys to scroll to display the ASCII character you want to use and press [*] to accept. 4. Press [*] to exit ASCII character entry mode and return to normal entry. NOTE: Authorized access to Connect24 (3G2055 (R) - E/TL2553G (R) -E) is required to modify any Ethernet/Cellular Programming Section. Specific panel sections must be configured for proper operation of the Communicator with the panel. Mounting Considerations The Cellular/Ethernet Communicator is a fixed, wall-mounted unit and shall be installed in the location specified in these instructions. The equipment enclosure must be fully assembled and closed, with all the necessary screws/tabs and it must be secured to a wall before operation. Internal wiring must be routed in a manner that prevents: Excessive strain on wire and on terminal connections, Interference between power limited and non power limited wiring, Loosening of terminal connections, or Damage of conductor insulation. WARNING: Never install this equipment during a lightning storm! The Installer must instruct the System user on each of the following items: This manual shall be used in conjunction with the Alarm controller manual; All the safety instructions specified within that manual shall be observed. Do not attempt to service this product. Opening or removing covers may expose the user to dangerous voltages or other risks. Any servicing shall be referred to trained service person only. Use authorized accessories only with this equipment. Cellular Coverage for Alarm Communicator Operation The HSPA/3G performance of the 3G2055(R)-E and TL2553G(R)- E Alarm Communicators depends greatly on Cellular network coverage. The SCW (with internal Alarm Communicator) should not be mounted in the final location without first ensuring that Cellular radio reception is adequate for communication using the HSPA/3G paths. Perform the “Communicator Placement Test” on page 9. Communicator Technical Specifications General Information All versions of the HSPA/3G and Ethernet Alarm Communicator, operate on a HSPA/3G network and are housed inside the Self Contained Wireless (SCW) 9055/9057. The Communicators use an Internal Antenna only. Each version of Alarm Communicators covered by this Installation Manual are described below: 3G2055-E: A High Speed Packet Access/Global System for Mobile (HSPA/3G) wireless Alarm Communicator that sends alarm communication to Sur-Gard System I, II, III (SG- DRL3IP), IV (SG-DRL4IP), and 5 (SG- DRL5IP) central station receivers via a HSPA/3G digital cellular network. 3G2055R-E: A High Speed Packet Access/Global System for Mobile (HSPA/3G) wireless Alarm Communicator that sends alarm communication to Sur-Gard System I, II, III (SG- DRL3IP), IV (SG-DRL4IP), and 5 (SG- DRL5IP) central station receivers via a HSPA/3G digital cellular network. This model also includes an interface for connecting to 3rd party applications. TL2553G-E: Is a dual-path Cellular/Ethernet Alarm Communicator that sends alarm communication to Sur-Gard System I, II, III, and IV central station receivers through Ethernet/Internet or a HSPA/3G digital cellular network. The dual path Communicator can be used as either a backup or primary Communicator. The Communicator supports Internet Protocol (IP) transmission of panel and internal events over Ethernet/Internet and/or HSPA/3G. TL2553GR-E: Is a dual-path Cellular/Ethernet Alarm Communicator that sends alarm communication to Sur-Gard System I, II, III, and IV central station receivers through Ethernet/Internet or a HSPA/3G digital cellular network. The dual path Communicator can be used as either a backup or primary Communicator. The Communicator supports Internet Protocol (IP) transmission of panel and internal events over Ethernet/Internet and/or HSPA/3G. This model also includes an interface for connecting to 3rd party applications. NOTE: For North America the following model names are available: 3G2055-E, 3G2055R-E, TL2553G-E and TL2553GR-E. CAUTION: Do not stay close to the equipment during device operation and to do not touch any exposed wires and other conductive surfaces, Recycle the battery according to the local rules and regulations. NOTE: Prior to installation of the 3G2055(R) - E or TL2553G (R) -E Communicator, confirm with your local carrier that the HSPA/3G network is available and active in the area where the Communicator will be installed, and that the location provides a radio signal strength that is adequate for uninterrupted service. Features 128-bit Advanced Encryption Standard (AES) encryption via HSPA/3G and Ethernet/Internet. Activating, initializing and remote programming through Connect 24. Back up or primary HSPA/3G/2G alarm communication. Does not require an external HSPA/3G/2G antenna. Ethernet LAN/WAN 10/100 BaseT (TL2553G(R)-E only). Full event reporting to central station. Fully redundant Ethernet/Internet and HSPA/3G/2G Dual-path Alarm Communication (TL2553G(R)-E only). Individual Ethernet and/or HSPA/3G periodic test transmission. 2-way audio (listen-in feature) provided over Cellular. Integrated call routing. Remote Firmware upgrade capability of the Communicator and Panel Firmware via Ethernet and/or HSPA/3G radio. Dual-Band Operation: 850 MHz, and 1900 MHz. (North America only) CID and SIA format reporting. Subscriber Identity Module (SIM) card included with Communicator. (North America only) Supervision heartbeats via HSPA/3G/2G and/or Ethernet/Internet. UL/ULC Installation Requirements For ULC Residential fire and burglary applications the 3G2055(R)-E/TL2553G(R)-E can be used as primary communication channel via either Cellular or Ethernet (as applicable) or as a back-up in conjunction with the Digital Alarm Communicator Transmitter (DACT). Test transmission every 24hours shall be enabled on each channel. For UL Residential fire and burglary applications the 3G2055(R)-E/TL2553G(R)-E can be used as primary communication channel via either Cellular or Ethernet, or as a back-up in conjunction with the DACT. (30 day test transmission is required on each channel). Communicator Frequency Bands for North America Table 2: 2G Frequency Bands Transmit Direction Cellular 850 North America PCS 1900 North America Transmit Frequency 824 MHz to 849 MHz 1850 MHz to 1910 MHz Receive Frequency 869 MHz to 894 MHz 1930 MHz to 1990 MHz Table 3: 3G Frequency Bands UMTS 850 North America, UMTS 1900 North America International Transmit Frequency 824 MHz to 849 MHz 1850 MHz to 1910 MHz Receive Frequency 869 MHz to 894 MHz 1930 MHz to 1990 MHz Transmit Direction Ratings Table 4: Communictor Electrical Ratings 3G2055(R)-E Cellular Only Model TL2553G(R)-E Ethernet and Cellular Power Supply Ratings Input Voltage 3.5 / 3.9 / 4.2 VDC (min / NOM / MAX) from the SCW panel Current Consumption 75mA 100mA Standby Current (@ 3.7V) 75mA 100mA Alarm (Transmitting) Current) 400 mA @ 3.7V during transmission Antenna Specifications Dual band Antenna See Table 2 and Table 3 Environmental Specifications Operating Temperature Humidity 0°C - 49°C (32°F- 120°F) 5% ~ 85% relative humidity, non-condensing Mechanical Specifications Board Dimensions (mm) Weight (grams) 109 x 110 60 65 Hardware Compatibility Table 5: Compatibility Communicator Receiver/Control Panel 3G2055(R)-E Receiver TL2553G(R)-E Control Panel Description Sur-Gard System I-IP Receiver, version 1.14+ Sur-Gard System II Receiver, version 2.11+ Sur-Gard SG-DRL3-IP, version 2.30+ (for Sur-Gard System III Receiver) Sur-Gard SG-DRL4-IP version 1.20+ (for Sur-Gard System IV Receiver) Sur-Gard SG-DRL5-IP version 1.00+ (for Sur-Gard System 5 Receiver) SCW9055/SCW9057 V1.00 Products or components of products, which perform communications functions only shall comply with the requirements applicable to communications equipment as specified in UL60950 or CAN/CSA-C22.2 No. 60950- 1, Information Technology Equipment - Safety - Part 1: General Requirements. Where network interfaces are internal to the control unit or receiver, compliance to CAN/CSA-C22.2 No. 60950- 1 is adequate. Such components include, but are not limited to: hubs; routers; NIDs; Third party communications service providers; DSL modems; and Cable modems. Software Compatability The Communicator is compatible with the following software: l Connect24 Using: Simple Messaging System (SMS) Protocol. Connect24 Remote Flash. Using: Internet Protocol (IP) using Trivial File Transfer Protocol (TFTP). Communicator Pre Intsallation Configuration Connect24™1 Account and SIM card Activation (Before Installation) Installation of the Communicator requires activation with Connect24 before operation. Dealer application forms and additional information on the Connect24 Voice Response Unit (VRU) and graphical user interface (GUI) can be found at http://www.Connect24.com or by telephone at: USA 1-888-251-7458 or CANADA 1-888-955-5583. IMPORTANT: Prior to installing a 3G2055(R)-E or TL2553G(R)-E Communicator, contact your monitoring station to determine if it is a master re-seller or visit http://www.Connect24.com to become an authorized dealer. In either instance, you will require a Profile Number, Installer ID Number, and an Installer Password. Perform the following pre installation: 1. Retrieve the installer account and password from the master reseller, or from Connect24 directly. 2. Connect your browser to the Connect 24 website at: http://www.Connect24.com or call VRU number. 3. Log in to the Connect24 website using your installer account and password. 4. Perform the following steps in a Connect24 session to activate the SIM card and initialize programming: a. Navigate to the Initialize an account section. b. Select Profile (This information will be provided by the master reseller or by Connect24). c. Select Product Module. d. Enter the SIM card number. e. Click Next then enter in all relevant information as required. f. Confirm all information is entered correctly before submitting. 5. Repeat Step 4 to program another SIM card (i.e. another Subscriber), or log out from Connect24. 6. When you are at the physical installation site, the Communicator will automatically connect and download its programming from Connect24 once the unit is initialized. 1. Connect24, DSC, and DLS IV are Registered Trademarks of Tyco International Ltd. and its respective Companies. All Rights Reserved. NOTE: Following initial installation, you can log in to the Connect24 website at any time to re-configure the Communicator remotely, using the account created for this installation. For more information, refer to the Connect24 website. Before leaving the installation site, the Communicator TL2553G(R)-E shall be connected via an APPROVED (acceptable to the local authorities) Network Interface Device (NID) (e.g., for UL Installations, U60950 listed NID). All wiring shall be performed according to the local electrical codes. Encryption The Communicator uses 128 Bit AES Encryption. Encryption can only be enabled from the monitoring station receiver. Each receiver can independently have encryption enabled or disabled. When encryption is enabled, the central station will configure the device to encrypt communications the next time the Communicator module performs a communication to that receiver. NOTE: Packets will start being encrypted only after the next event is sent to that receiver, or if the unit is restarted. Communicator Configuration with SCW Figure 1: Communication Board Connection Points SIM Card Holder RJ-45 Connector (TL2553G(R)-E only) Mounting Hole UA684 Mounting Hole NOTE: The Alarm Communicator is installed in the SCW prior to shipment by Digital Security Controls (DSC). The Factory Installation includes insertion of the SIM card. The SCW should not be mounted in its final location without performing a Communicator Test to ensure adequate HSPA/3G coverage for the 3G2055 (R)- E and TL2553G (R)- E Alarm Communicators Installation Location The Communicator shall be installed in an indoor location only. This HSPA/3G/Ethernet Communicator shall be installed by Service Persons only. (Service Person is defined as a person having appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed in performing a task and of measures to minimize the risks to that person or other persons). The Communicator shall be installed and used within an environment that provides the pollution degree max 2, over voltages category II, in non-hazardous, indoor locations only. This manual shall be used with the Installation Manual of the alarm control panel which is connected to the HSPA/3G/Ethernet Communicator. All instructions specified within the control panel manual must be observed. All the local rules imposed by local electrical codes shall be observed and respected during installation. Installing CAT 5 Cable (TL2553G(R)-E only) A Category 5 (CAT 5) ethernet cable must be run from a source with Ethernet/Internet connectivity to the Communicator module, inside the Self Contained Wireless Control Panel cabinet. The Communicator end of the cable must have an RJ-45 plug, which connects to the Communicator’s RJ-45 jack. All requirements for installation of CAT5 ethernet cable must be observed for correct operation of the Communicator, including, but not limited to, the following: Do NOT strip off cable sheathing more than required for proper termination. Do NOT kink/knot cable. Do NOT crush cable with cable ties. Do NOT untwist CAT5 pairs more than 1.2cm (½”). Do NOT splice cable. Do NOT bend cable at right angles or make any other sharp bends. Figure 2: RL-45 Pinout RJ-45 Connector NOTE: CAT5 specification requires that any cable bend must have a minimum 5 cm (2 in.) bend radius. Maximum length of CAT 5 cable is 100m (328 ft.). NOTE: The Ethernet cable shall not be visible when the installation is complete unless the install is a surface mount installation. INSERTING/REMOVING THE SIM CARD Figure 3: SIM Card Pinouts SIM Card Pinouts Vcc GND Reset Vpp CLK I/O 1. Remove the front cover of the SCW Control Panel to access SIM card holder. 2. Remove power from the SCW and disconnect the backup batteryconnections. 3. On the SIM card holder push gently to slide the cover towards OPEN as indicated by the arrow on SIM holder. This will unlatch the SIM card holder on the side furthest from edge of the Communicator. See Figure 1. 4. Lift up the SIM card holder from the side that is not hinged. NOTE: The SIM card can be damaged by bending or scratching contacts. Use caution when handling the SIM card. 5. Insert or remove the SIM card, noting the orientation of the notches on the SIM card and the SIM card holder. 6. When inserting a SIM card, insert the card in the proper orientation and gently push the SIM card holder down and slide the holder as indicated by the arrow on SIM holder, to LOCK. 7. Apply AC power to panel, and replace the panel cover. NOTE: If two way audio is enabled you will NOT be able to swap the SIM card with another card. Communicator Reset The Communicator can be reset by cycling the power on the SCW. Establishing a Communication Channel with the SCW Panel. The Communicator interfaces to the SCW through a keyed 16 pin Ribbon cable. See Table 6 . The key prevents incorrect connection of the ribbon cable connector to the SCW and Communicator. The pinout for the Ribbon cable is provided in the Table below: Table 6: Communicator Ribbon cable to SCW Pin # Signal Pin # Signal PC-Link TX 2 PC-Link RX GND Vref Vref GND AUD-OUT_N 8 AUD_OUT_P AUD-IN_P 10 AUD-IN_N 11 GND 12 SI 13 GND 14 SO 15 GND 16 Wall Tamper 10 Establishing a communication channel between the Communicator and the SCW is critical to ensuring the desired operation of the two units. The following steps must be completed during the on- site installation. Program the following to ensure that the Communicator and the panel will work together as intended. Initial Programming of Communicator and SCW 1. Enter [*][8][Installer Code] [Section Number] for panel programming. Record any values that are modified from their default, in the appropriate Programming Worksheets. NOTE: When programming Toggle Options, the toggle is ON when the number is displayed and OFF when the number is not dis played. (e.g., [1---5---], Toggle Options 1 and 5 are ON, all others are OFF). 2. Panel Section [167] Cellular/Ethernet Interface Communications ‘Wait for ACK’: Default value is: 060 seconds. 3. When the communicator is installed with the SCW panel, 4 telephone numbers are available to backup one another. You can set up these 4 telephone numbers to perform in one of two ways: Backup dialling or Alternate dialling. a. Backup dialling: each of the 4 telephone numbers will make 5 dialling attempts in turn, before an FTC trouble is displayed on the keypad. b. Alternate dialling: each telephone number makes 1 dialling attempt before moving on to the next number, cycling through each of the 4 numbers for a total of 5 times each. If all 4 numbers fail the 5 attempts, an FTC trouble is displayed on the keypad. 4. Panel Sections [301], [302], [303], and [305] can be configured as Primary communication paths. a. Panel Sections [302], [303], and [305] may also be configured for backup or redundant communications by using Panel Section(s) [383] or [351] - [376]. Refer to the SCW panel Installation Manual for more information. b. If a valid telephone number is programmed, communications will use Public Switched Telephone Network (PSTN). Entering a 4 digit hexadecimal value for a telephone number will change the call routing to the Communicator, as determined by the number programmed: DCAAF: Internal (All Receivers). Signals will be routed depending on Section [851] [006] programming. DCBBF: Ethernet Receiver 1 (Primary). (Not available for 3G2055(R)-E). DCCCF: Ethernet Receiver 2 (Backup). (Not available for 3G2055(R)-E). DCDDF: Cellular Receiver 1 (Primary). DCEEF: Cellular Receiver 2 (Backup). NOTE: Add a single ‘F’ as a suffix to the 4 digit hex number to populate the unused remainder of the 32 character field. 5. Panel Section [350]: If any of the phone numbers have been programmed as DCAA, DCBB, DCCC, DCDD, or DCEE, panel Section [350] must be set to [04] if SIA format or [03] if Contact ID (CID) format is used by control panel. 6. Panel Section [382]: Toggle Option [5], ‘GS/IP Module Enabled’, must be set to ON. 7. Panel Section [401]: Toggle Option [1] must be set to ON in order to perform panel DLS session through Cellular or Ethernet data channel. 8. Panel section [310], account code, auto syncs with the communicator account code in section [021]. The panel account code ([*][8][installer code] [310]), will overwrite the communicator account code section ([*][8][installer code] [850] [021]) if programmed differently. NOTE: Keep a record of the SIM card telephone number, it is required by users for SMS Command and Control functions. (The number can be recorded in the Programming Worksheets Section of this document, under Option [996]). Due to the nature of the SIM card activation process with Cellular network carriers, it can take up to 24 hours for SIM card activation to be complete. SMS Command and Control Functions SMS Command and Control is available on SCW9055/57 panels. Users can send SMS text messages from their mobile phone to the GSM phone number assigned to their system. Commands are only accepted from telephone numbers that have been programmed in Sections [311]- [318]. The system will reject messages sent from telephone numbers that are not on the programmed list. When the received SMS text matches a valid Section message, the function is performed on the control panel. Text messages are not case sensitive and extra spaces are ignored. A User Access Code may be required for some SMS messages. The SMS Message format is in 3 parts: Command, Partition Label (or only the partition number), and Access Code. If an Access Code is included in the message, it is sent to the control panel for validation, along with the requested function. If the panel is configured to require an Access Code and the code is not sent (or invalid) the panel will fail the function (unsuccessful). If the panel fails the function, an SMS response message is sent to the user. The SMS response will echo the command sensat, followed by the label “unsuccessful”. (e.g., “night arm partition 2 1234 unsuccessful”). The partition label or partition number may be excluded from the SMS request in a single partition system (e.g., disarm 9123). NOTE: The GSM phone number can be viewed in Section [851] [996], and/or [851] [229] or by entering *6, then scrolling down to “SMS Programming” and scrolling down to “Cellular phone No”. Label Programming for SMS Message Programmable Labels can not be modified in Connect24, use DLS IV for label programming only, if labels need to be modified. Before initiating remote programming, record your network’s Public IP Address and port for incoming DLS IV connections. 11 1. Run the DLS IV software on your computer. DLS IV will connect to the unit, using the Public IP address, and make an Ethernet connection. If the Ethernet connection fails, DLS IV will report an error and prompt you to connect using Cellular. NOTE: If required, download the DLS IV software from DSC: http://www.dsc.com/index.php?n=library#self. If you select Cellular connection, DLS will request Connect24 to send an outgoing SMS message to the unit. 2. Connect24 will confirm that the account has DLS service and will provide the Public IP address and port number of the DLS server in an SMS message. 3. SMS message will establish a connection to your computer’s DLS IV software (to change programming labels only). 4. Create an account for the panel/Communicator, select the Communicator type (e.g., SMS - TL2553GR-E) and enter all relevant information in SMS section. NOTE: The Cellular telephone number will also be required by the user, to send SMS Command and Control messages to their system. 5. Program the account information, then click Global Download and choose SMS as the Connection Type. Click OK. 6. The download path configured in Programming Section [005] Toggle Option[4] determines the Cellular or Ethernet path to be used. Communicator Placement Test (3G2055(R)-E / TL2553G(R)-E only) 1. Using the keypad enter the installer mode: [*][8] [installer code] [850]. 2. View and record the number of bars showing on the SCW LCD. 3. Compare with the number of bars indicated in the “CSQ Levels” column shown in Table 7 . 4. If 3 or more bars are shown, the location is GOOD and no further action is required. 5. If the location is BAD, move the SCW to various suitable locations until 3 or more bars are obtained. Table 7: Communicator CSQ Levels Signal Strength CSQ Level Signal Level (dBm) Installer Action No Signal -108.8 Check if Cellular coverage is active in your area. 1 Bar 1 to 4 -108 to -103 Location is BAD. Not suitable for Cellular operation. 2 Bars 5 to 6 -102 to -99 3 Bars 7 to 10 -98 to -90 4 Bars 11 to 13 -90 to -85 Location is GOOD. 5 Bars 14 and higher -84 and higher NOTE: The communicator is capable of indicating signal strength even without an active SIM, but signal indication may take up to 1-2 minutes. Ethernet/Cellular Programming Options The Programming Sections described in this document can be viewed at the SCW LCD. To start programming enter: [*][8] [installer code] [851][###], Where ### is the 3 digit Section number referenced in this section. The Programming Worksheets at the end of this document can be used to record the new values when programming changes have been made from the default values. Programming Sections are accessed through Connect24. Installers may review/record programming Options at the panel. NOTE: Ethernet/Cellular Programming Sections accessed through the panel are for display purposes only. Configuration changes must be done using Connect24. System Options [001] Ethernet IP Address Default (000.000.000.000) Enter the IP address of the Communicator. Ensure that the IP address is unique to your Communicator on the local network. Format is 4 fields, each field is a 3 digit decimal number. Valid range: 000- 255. If an IP address is programmed in this Section, the unit will operate with Static IP (DHCP disabled). Sections [002] and [003] must also be programmed when using Static IP addresses. NOTE: Default for this Section is Dynamic Host Configuration Protocol (DHCP) enabled. When enabled, the DHCP Server will set values for: IP Address [001], Subnet Mask [002], and Gateway [003]. Programming an IP address in this Section will disable DHCP (Static IP). [002] Ethernet IP Subnet Mask Default (255.255.255.000) Enter the Ethernet IP Subnet Mask of the Communicator. Format is 4 fields, each field is 3 digits. Valid range: 000-255. NOTE: If DHCP is enabled, the DHCP Server will assign the subnet mask for this Section and the programmed value will be ignored. 12 [003] Ethernet Gateway IP Address Default (000.000.000.000) Enter the Ethernet Gateway IP address of the Communicator. The gateway IP address is required when a router is used on the local network to reach the destination IP address specified in Section [001]. Format is 4 fields, each field is a 3 digit decimal number. Valid range: 000-255. NOTE: If DHCP is enabled, the DHCP Server will assign the Gateway IP address for this Section and the programmed value will be ignored. [004] Receiver Supervision Interval Default (0087/135) When receiver supervision is enabled (ON) in Section [005] Toggle Option [3], the unit sends heartbeats to Ethernet Receiver 1 or Cellular Receiver 1 to test the communications path. Use this Section to set the interval time (in seconds) when heartbeats will be sent to the receivers. Valid range 000A-FFFF seconds. If the programmed value is less than (000A/10) seconds, supervision is disabled. Receiver Window: This is the supervision timeout that must be configured at the central station receiver. Recommended Values: This is the recommended heartbeat interval that should be programmed into the Communicator. For ULC installations, the Daily test transmission must be enabled over each available communication channel Sections [125] and [225]. When programming with Connect24, the recommended intervals will be programmed automatically when the required window is selected. [005] System Toggle Options [1] Ethernet Receiver 1 Supervised Default (OFF) (TL2553G(R)-E only). ON: Ethernet Receiver 1 will be supervised and heartbeats will be sent to Ethernet Receiver 1 based on the supervision interval programmed in Section [004]. OFF: Ethernet Receiver 1 will not be supervised. When disabled, heartbeat 1 is sent to the Ethernet receiver once every hour, regardless of supervision type (heartbeat 1 or 2). The heartbeat is resent every 5 seconds until ACK. If no event or heartbeat ACK is received after (Receiver Supervision Interval + 75 seconds), Supervisory trouble is indicated. NOTE: Ethernet Receiver 2 can not be supervised. [2] Cellular Receiver 1 Supervised Default (OFF) ON: Cellular Receiver 1 will be supervised and heartbeats will be sent to Cellular Receiver 1 based on the supervision interval programmed in Section [004]. If ACK to heartbeat is not received, it is retransmitted every 5 seconds. Failure to ACK 2 consecutive heartbeats will reset the radio. OFF: Cellular Receiver 1 will not be supervised. When disabled, heartbeat is not sent to the receiver. Supervisory trouble is indicated. NOTE: Cellular Receiver 2 can not be supervised. [3] Supervision Type Default (OFF) ON: Heartbeat 1 (Commercial Supervision). This supervision type is suitable for applications where swap detection is required on the supervisory packet. OFF: Heartbeat 2 (Residential Supervision). This supervision type is suitable for applications where supervision of the communication path to the receiver is required. (no swap detection). NOTE: Commercial supervision is more data intensive than residential supervision and should only be used when required to meet the approval for the installation. [4] Primary Path Default (OFF - TL2553G(R)-E) (ON - 3G2055(R)-E) ON: Cellular channel is the primary path. Ethernet channel is the secondary path, if it exists. OFF: Ethernet channel is the primary path in a dual Communicator. Cellular channel is the secondary path. [5] Redundant Communications Default (OFF) (TL2553G(R)-E only) ON: Events will be communicated to Ethernet Receiver 1 and Cellular Receiver 1 at the same time. Events will be communicated to Ethernet Receiver 2 and Cellular Receiver 2 at the same time. As long as the event is successfully communicated to 1 of the 2 paths (Ethernet or Cellular) the Communicator will move on to the next event. NOTE: Do not configure Ethernet Receiver 1 and Cellular Receiver 1 to communicate using a common receiver configuration (i.e., identical Receiver IP address and Receiver Remote Port). OFF: Events will be communicated to the receivers individually. Toggle should be OFF when guaranteed message delivery to both receivers is required. [6] Remote Firmware Upgrade Default (ON) ON: The Communicator module firmware can be remotely upgraded using the Ethernet/Cellular paths. OFF: The Communicator module firmware can not be remotely upgraded. Local firmware upgrade is still possible. [7] Alternate Test Transmissions Default (OFF). 13 ON: When the periodic test transmission interval occurs, the test transmission will alternate between being sent to the primary and secondary receivers with each test transmission interval. OFF: When the periodic test transmission interval occurs, the test transmission will be sent to the programmed receivers, based on the settings of the periodic test transmission reporting codes. [8] Cellular Low Signal Trouble. Default (OFF) This option masks the Low Signal trouble from the Cellular trouble event. ON: A Cellular Trouble event is transmitted to receiver when the radio signal level falls below threshold level (average CSQ level is 4 or less). OFF: A Cellular Trouble event is not transmitted to receiver when the radio signal level falls below threshold level (average CSQ level is 4 or less). [006] System Toggle Options 2 [1] Ethernet 1 Receiver Enabled. Default (ON) (OFF for 3G2055(R)-E). ON: Ethernet Receiver 1 is enabled. OFF: Ethernet Receiver 1 is disabled. [2] Ethernet 2 Receiver Enabled. Default (ON) (OFF for 3G2055(R)-E). ON: Ethernet Receiver 2 is enabled. OFF: Ethernet Receiver 2 is disabled. [3] Reserved. ( ). [4] Cellular 1 Receiver Enabled. Default (ON). ON: Cellular Receiver 1 is enabled. OFF: Cellular Receiver 1 is disabled. [5] Cellular 2 Receiver Enabled. Default (ON). ON: Cellular Receiver 2 is enabled. OFF: Cellular Receiver 2 is disabled. [6] Reserved ( ). [7] DLS Over Cellular. Default (ON). NOTE: Program this toggle as OFF if you want to completely disable DLS from using the Cellular path. ON: DLS is enabled on the Cellular path. OFF: DLS is disabled on the Cellular path. NOTE: If this Toggle is OFF, DLS sessions will occur on the Ethernet path only, regardless of Primary Path set in Section [005] Toggle Option [4]. If it is ON then the Communicator will connect to the Primary path first for DLS and if the session fails, the Secondary path will be used. [8] Reserved ( ). [007] DNS Server IP 1 Default (000.000.000.000) Programming this Section is not permitted on a UL/ULC listed system. Enter the IP address for DNS Server 1. Format is 4 fields, each field is a 3 digit decimal. Valid range: 000-255. NOTE: If no value is programmed and DHCP is used, the DHCP Server will configure the address. If an address is programmed and DHCP is used, the address that you program will be used instead of the DHCP address. [008] DNS Server IP 2 Programming this Section is not permitted on a UL/ULC listed system. Default (000.000.000.000) Enter the IP address for DNS Server 2. Format is 4 fields, each field is a 3 digit decimal. Valid range: 000-255. NOTE: If no value is programmed and DHCP is used, the DHCP Server will assign this value. If an address is programmed and DHCP is used, the address that you program will be used instead of the DHCP address. Programming Options [010] System Toggle Option Default (Disable) [1] This bit is used to enable/disable two way audio over 3G. [011] Installer Code Default (CAFE) Program your installer code for this Communicator module. The installer code will be required when programming the Communicator module. Valid range: 0000 - FFFF. 14 [012] DLS Incoming Port Default (0BF6/3062) The DLS Incoming Local Port (listening port) is the port DLS IV will use when connecting to the Communicator. If a router or gateway is used, it must be programmed with a Transmission Control Protocol (TCP) port forward for this port to the Communicator module IP address. Valid range: 0000 - FFFF. [013] DLS Outgoing Port Default (0BFA/3066) The DLS Outgoing Port is used for outgoing session to DLS IV after an SMS request has been sent to the Communicator. Use this Section to set the value of the local outgoing port. The value must be changed if the Communicator is located behind a firewall and must be assigned a particular port number, as determined by your network administrator. In most cases, changing the default value or configuring your firewall with this port is not required. Valid range: 0000-FFFF. NOTE: If Section [006] Toggle Option [7] is ON, DLS will use the Primary path for session. If Section [006] Toggle Option [7] is OFF DLS will use the Ethernet path, if available. [020] Time Zone Default (00) Use Column 2 (Offset Hours) to find your local Time Zone. Record the two digit HEX value from Column 1 (HEX Value) on the same row. Program this HEX value for your Time Zone. Valid range is 00 - FF. Table 8: World Wide Time Zones HEX Value 01 05 09 0B 0D 11 15 19 1D 1F 21 23 25 29 2D 31 35 39 3D 3F 41 43 45 47 48 49 4B Offset Hours -12 -11 -10 -9.5 -9 -8 -7 -6 -5 -4.5 -4 -3.5 -3 -2 -1 3.5 4.5 5.5 5.75 6.5 Standard Abbreviation BIT SST HAST MIT AKST PST MST CST EST VST AST NST ART BEST CVT GMT CET SAST AST IRST GST AFT PKT IST NPT VOST MMT Location Baker Island Time Somoa Standard Time Hawaii-Aleutian Standard Time Marquesas Island Time Alaska Standard Time Pacific Standard Time Mountain Standard Time Central Standard Time Eastern Standard Time Venezuela Standard Time Atlantic Standard Time Newfoundland Standard Time Argentina Time Brazil Eastern Standard Time Cape Verde Time Greenwich Mean Time (UTC) Central European Time South Africa Standard Time Arabic Standard Time Iran Standard Time Gulf Standard Time Afghanistan Time Pakistan Time Indian Standard Time Nepal Time Vostok Time Myanmar Time 15 HEX Offset Value Hours 4D 51 52 8.25 54 8.75 55 57 9.5 59 10 5B 10.5 5D 11 5F 11.5 61 12 64 12.75 65 13 69 14 70-FF N/A Standard Abbreviation BDT CST APO ACWST KST ACST AEST LHST VUT NFT NZST CHAST TOT LINT N/A Location Bangladesh Standard Time China Standard Time Apo Island Time Australian Central Western Standard Time Korea Standard Time Australian Central Standard Time Australian Eastern Standard Time Lord Howe Standard Time Vanuatu Time Norfolk Island Time New Zealand Standard Time Chatham Island Standard Time Tonga Time Line Island Time N/A [021] Account Code Default (FFFFFF) The account code is included when transmitting any events generated by the Communicator. (e.g., Panel Absent Trouble). It is recommended that the account code be the same as the control panel account number. Valid range: 000001-FFFFFE. If 4 digit account codes are needed the 2 lowest digits shall be programmed as FF. (e.g., Account 1234 is programmed as:1234FF). NOTE: Programming this Section with all 0 or F will cause a Module Configuration Trouble. [022] Communications Format Default (04) Program 03 for Contact ID (CID). Program 04 for SIA. The module can be configured to send Events in SIA or CID format. The SIA communication format follows the level 2 specifications of the SIA Digital Communication Standard - October 1997. This format will send the account code along with its data transmission. The transmission will look similar to the following at the receiver. Example: Nri0 ET001 Where: N = New Event; ri0 = Partition/Area identifier; ET = Panel Absent Trouble; 001 = Zone 001. Communications Reporting Codes Table 9: Communications Reporting Codes Event [023] Panel Absent Trouble [024] Panel Absent Trouble Restore [025] Radio Activation Restore [026] Ethernet 1 Test Transmission [027] Ethernet 2 Test Transmission [028] Cellular 1 Test Transmission [029] Cellular 2 Test Transmission [030] FTC Restore CID CID SIA SIA CID CID Identifier Reporting Code Qualifier Event Code Reporting Code User/ Zone ET ER RS RP RP RP RP YK 001 001 001 001 002 003 004 001 55 55 52 A3 A3 A3 A3 54 001 001 001 951 952 955 956 001 [023] Panel Absent Trouble Default (FF) Program 00 to disable this event or FF to enable. This event will occur when communications with the panel have been lost for more than 60 seconds. [024] Panel Absent Trouble Restore Default (FF) 16 Program 00 to disable this event or FF to enable. This event will occur when communications with the control panel have resumed. [025] Radio Activation Restore Default (FF) Program 00 to disable this event or FF to enable. This event will occur after any successful Connect24 programming session. System Test Options [026 - 029] Test Transmissions to Primary Receiver, with Backup to Secondary Receiver: Set Ethernet Section [026] to (FF); [027] to (00). Set Cellular Section [028] to (FF); [029] to (00). If the test transmission fails to the primary receiver it will backup to the secondary receiver. If the test transmission fails to the secondary receiver an FTC trouble will be generated. Test Transmission Unique to Primary and Secondary Receivers: Set Ethernet Section [026] to (FF); [027] to (FF). Set Cellular Section [028] to (FF); [029] to (FF). The module will send periodic test transmissions to each receiver independently, with no backups. If the test transmission fails to any of the programmed receivers, an FTC trouble will be generated. Alternate Test Transmission: Alternate Test Transmission can be enabled or disabled in Section [005] Toggle Option [7]. [026] Ethernet 1 Transmission Default (FF) Program 00 to disable this event transmission or FF to enable. See System Test Options (above) for details on settings. [027] Ethernet 2 Transmission Default (00) Program 00 to disable this event transmission or FF to enable. See System Test Options (above) for details on settings. [028] Cellular 1 Transmission Default (FF) Program 00 to disable this event transmission or FF to enable. See System Test Options (above) for details on settings. [029] Cellular 2 Transmission Default (00) Program 00 to disable this event transmission or FF to enable. See System Test Options (above) for details on settings. NOTE: The time interval (in minutes) between periodic tests is programmed in Section [125] (Ethernet) and Section [225] (Cellular). [030] FTC Restore Default (FF) Program 00 to disable this event transmission or FF to enable. This event will occur when an FTC Trouble on the system restores. [031] Priority Tamper Alarm Program 00 to disable this event or FF to enable. This event will occur when panel tampered during the entry delay. [032] Priority Tamper Restore Program 00 to disable this event or FF to enable.This event will occur when panel tamper restored. Table 10: Priority Temper Restore SIA SIA Reporting Contact ID Contact ID Contact ID Contact ID Identifier Code Qualifier Event Code Reporting Code User/Zone Priority Tamper BA 000 37 000 Priority Tamper Restore BR 000 37 000 Event [033] Communicator Firmware Update Begin Default (FF); Program 00 to disable this event transmission or FF to enable. This event will occur when the communicator firmware update begins. [034] Communicator Firmware Update Successful Default (FF); Program 00 to disable this event transmission or FF to enable. This event will occur when the communicator firmware update successfully completed. [035] Panel Firmware Update Begin Default (FF); 17 Program 00 to disable this event transmission or FF to enable. This event will occur when the panel firmware update begins. [036] Panel Firmware Update Successful Default (FF); Program 00 to disable this event transmission or FF to enable. This event will occur when the panel firmware is updated successfully. [037] Panel Firmware Update Fail Default (FF); Program 00 to disable this event transmission or FF to enable. This event will occur when the panel firmware updated has failed. Table 11: Panel Tamper Alarm Restore SIA Contact ID SIA Contact ID Contact ID Contact ID Reporting Reporting Identifier Qualifier Event Code Code User/Zone Code [033]Comm. FW Update Begin LB 00 03 002 [034]Comm. FW Update Successful LS 00 03 002 [035]Panel FW Update Begin LB 00 03 003 [036]Panel FW Update Successful LS 00 03 003 [037]Panel FW Update Fail LU 00 04 003 Event Ethernet Receiver 1 Options [101] Ethernet Receiver 1 Account Code Default (0000000000) The account code is used by the central station to distinguish between transmitters. This account code is used when transmitting heartbeat signals to the central station receiver. Signals received from the Panel will use the control panel account number. Valid range: 0000000001-FFFFFFFFFE. Programming all 0 or all F will cause a Module Configuration Trouble. NOTE: If Ethernet Receiver 1 and Cellular Receiver 1 are programmed as the same receiver (IP and port number are identical), Ethernet Receiver 1 account code will be used. [102] Ethernet Receiver 1 DNIS Default (000000) The Dialled Number Information Service (DNIS) is used in addition to the Account Code to identify the Communicator module at the central station. Valid range: 000000 - 099999. Value is entered as a leading 0 followed by the 5 digit DNIS. Format is Binary Coded Decimal (BCD). NOTE: Each Ethernet/Cellular receiver must be programmed with a unique DNIS. [103] Ethernet Receiver 1 Address Default (127.000.000.001) The default address enables the Communicator to operate in Unattended Mode. Unattended Mode is used when a receiver is not available and the unit is required to perform DLS sessions. Typically used where the customer programs the control panel daily due to access control and still wants to receive alarms without buying extra hardware (receiver) or software. NOTE: When a valid IP address has been programmed, Ethernet Receiver 1 is enabled and will communicate events over the Ethernet channel. Ethernet Receiver 1 and Cellular Receiver 1 may be configured to communicate to the same central station receiver. To configure the device to operate using this Common Receiver Mode functionality, program Ethernet Receiver 1 and Cellular Receiver 1, IP address and port number with identical values. NOTE: When operating in Common Receiver Mode, Ethernet Receiver 1 account code will be used for Ethernet and Cellular. [104] Ethernet Receiver 1 Remote Port Default (0BF5/3061) This Section determines the remote port of Ethernet receiver 1. Valid range: 0000 - FFFF. [105] Ethernet Receiver 1 Local Port Default (0BF4/3060) Use this Section to set the value of the local outgoing port. Set the value of this port when your installation is located behind a firewall and must be assigned a particular port number as determined by your central station system administrator. Valid range: 0000 - FFFF. [106] Ethernet Receiver 1 Domain Name Default ( ) 18 Enter the Domain Name as 32 ASCII characters. Programming this Section is not permitted on a UL/ULC listed system. Ethernet Receiver 2 Options [111] Ethernet Receiver 2 Account Code Default (0000000000) The account code is used by the central station to distinguish between transmitters. The account code is used when transmitting heartbeat signals to the central station receiver. Signals received from the control panel will use the control panel account number. Valid range: 0000000001- FFFFFFFFFE. Programming all 0 or all F will cause a Module Configuration Trouble (yellow LED=12 flashes). NOTE: If both Ethernet Receiver 2 and Cellular Receiver 2 are the same receiver (IP and port number are identical), Ethernet Receiver 2 account will be used for Ethernet and Cellular. [112] Ethernet Receiver 2 DNIS Default (000000) The DNIS is used in addition to the account code to identify the Communicator module at the central station. Valid range: 000000 - 099999. Value is entered as leading 0 followed by the 5-digit DNIS. Format is BCD. NOTE: Each Ethernet/Cellular receiver must be programmed with a unique DNIS. [113] Ethernet Receiver 2 Address Default (000.000.000.000) Programming the Ethernet receiver 2 IP address with 000.000.000.000 will disable Ethernet. Enter the Ethernet receiver 2 IP address. This address will be provided by your central station system administrator. Format is 4 fields, each field is a 3-digit decimal. Valid range: 000-255. NOTE: When a valid IP address has been programmed, Ethernet Receiver 2 is enabled and will communicate events over the Ethernet channel. Ethernet Receiver 2 and Cellular Receiver 2 may be configured to communicate to the same central station receiver. To configure the device to operate using this common receiver mode functionality, program the Ethernet Receiver 2 and Cellular Receiver 2, IP address and port number with the same values. When operating in common receiver mode the Ethernet Receiver 2 account code will be used for communications over Ethernet and Cellular. NOTE: Do not program Ethernet Receiver 1 and Ethernet Receiver 2 to communicate to same receiver. [114] Ethernet Receiver 2 Remote Port Default (0BF5/3061) This Section is used to program the port number used by Ethernet Receiver 2. Set the value of this port when your installation is located behind a firewall, and must be assigned a particular port number as determined by your central station system administrator. Valid range: 0000 - FFFF. NOTE: Do not program Ethernet Receiver 1 and Ethernet Receiver 2 Port with the same value. [115] Ethernet Receiver 2 Local Port Default (0BF9/3065) Use this Section to program the value of the local outgoing port. You can set the value of this port when your installation is located behind a firewall and must be assigned a particular port number as determined by your network administrator. Valid range: 0000 - FFFF. NOTE: Do not program Ethernet Receiver 1 and Ethernet Receiver 2 Port with the same value. [116] Ethernet Receiver 2 Domain Name Default ( ) Programming this Section is not permitted on a UL/ULC listed system. Enter the Domain Name as 32 Character ASCII. Ethernet Options [124] Ethernet Test Transmission Time Default (9999) Enter a 4 digit number (0000-2359) using the 24-hour clock format (HHMM) to set the test transmission time of day. Valid range: 00 - 23 hours (HH) and 00 - 59 minutes (MM). Programming a value of 9999 will disable the test transmission time. NOTE: The internal date and time will automatically be programmed when the unit communicates with the primary receiver. [125] Ethernet Test Transmission Cycle Default (000000) This value represents the interval between test transmissions, in minutes. Valid range: 000000 - 999999 minutes. Once the unit has sent the initial periodic test transmission, all future test transmissions will be offset by the programmed number of minutes. See Sections [026] - [029]. 19 Table 12: Ethernet Test Transmission Interval Test Transmission Interval Daily Programmed Minutes 001440 Weekly 010080 Monthly 043200 NOTE: Minimum value is 000005 minutes. Programming an interval that is less than 5 minutes will disable test transmission. Cellular Receiver 1 Options [201] Cellular Receiver 1 Account Code Default (0000000000) The account code is used by the central station to distinguish between transmitters. This account code is used when transmitting heartbeat signals to the central station receiver. Signals received from the control panel will use the control panel account number. Valid range: 0000000001 - FFFFFFFFFE. Programming all 0 or all F will cause a Module Configuration Trouble (yellow LED = 12 flashes). [202] Cellular Receiver 1 DNIS Default (000000) The DNIS is used in addition to the account code to identify the Communicator module at the central station. Valid range: 000000 - 099999. Values are entered as leading 0 followed by the five digit DNIS. Format is BCD. NOTE: Each Ethernet/Cellular receiver must be programmed with a unique DNIS. [203] Cellular Receiver 1 Address Default (000.000.000.000) Enter the Cellular Receiver 1 IP address. This information will be provided by your central station system administrator. Each 3digit segment of the address must be within a valid range of 000-255. NOTE: When a valid IP address has been entered, the Cellular is enabled and will communicate events over the Cellular channel. [204] Cellular Receiver 1 Port Default (0BF5/3061) This Section determines the port used by Cellular Receiver 1. Change the default value of this port when your installation is located behind a firewall, and must be assigned a particular port number as determined by your central station system administrator. Valid range: 0000 - FFFF. NOTE: Programming this Section with 0000 will disable the receiver. [205] Cellular Receiver 1 APN Default ( ) The Access Point Name (APN) determines the Cellular network that the Communicator will connect to. This information is available from your network carrier. Program this Section as 32 ASCII characters. NOTE: When a SIM card with a custom APN is used, the unit will not have access to the Internet. DLS and remote flash can still be done if Section [221] is programmed with a valid Public APN. [206] Cellular Receiver 1 Domain Name Default ( ) Programming this Section is not permitted on a UL/ULC listed system. Enter the Domain Name as 32 ASCII characters. This information will be provided by your central station system administrator. Cellular Receiver 2 Options [211] Cellular Receiver 2 Account Code Default (0000000000) The account code is used by the central station to distinguish between different transmitters. This account code is used when transmitting signals to the central station receiver. Signals received on the panel will use the panel account number. Valid range: 0000000001 - FFFFFFFFFE. NOTE: Programming this Section as all 0 or F will cause a Module Configuration Trouble (yellow LED = 12 flashes). [212] Cellular Receiver 2 DNIS Default (000000) The DNIS is used in addition to the Account Code to identify the Communicator module at the central station. Valid range: 000000 - 099999. Values are entered as a 0 followed by the 5 digit DNIS value. Format is BCD. NOTE: Each Ethernet/Cellular receiver must be programmed with a unique DNIS. [213] Cellular Receiver 2 Address Default (000.000.000.000) Enter the Cellular Receiver 2 IP address. This IP address will be provided by your central station. Format is 4 fields, each field is 3-digit decimal. Valid range: 000 - 255. 20 NOTE: When a valid address has been entered, Cellular Receiver 2 is enabled and will communicate events over the Cellular path. [214] Cellular Receiver 2 Port Default (0BF5/3061) This Section defines the port of Cellular Receiver 2. Change the value of this port when your installation is located behind a firewall and must be assigned a particular port number, as determined by your central station system administrator. Valid range: 0000 - FFFF. NOTE: Do not program Cellular Receiver 1 and Cellular Receiver 2 to communicate to the same receiver. [215] Cellular Receiver 2 APN Default ( ) The APN determines the Cellular network that the Communicator will connect to. This information is available from your network carrier. Program this Section with up to 32 ASCII characters. NOTE: When a SIM card with a custom APN is used, the unit will not have access to the internet. DLS and remote flash can still be done if Section [221] is programmed with a valid Public APN. [216] Cellular Receiver 2 Domain Name Default ( ) Programming this Section is not permitted on a UL/ULC listed system. Enter the Cellular Receiver 2 Domain Name with up to 32 ASCII characters. Cellular Options [221] Cellular Public Access Point Name Default ( ) When the Communicator is operating on a private APN, use this Section to select a public APN for DLS and Remote Firmware Update. This information is available from your network carrier. The APN identifies the public Cellular network that the Communicator will connect to. [222] Cellular Login User Name Default ( ) Some network carriers require you to provide login credentials when connecting to an APN. Program your login User Name in this Section. Format is up to 32 ASCII characters. NOTE: This Section is not accessible via SCW keypad programming. [223] Cellular Login Password Default ( ) Some network carriers require you to provide login credentials when connecting to an APN. Program your login Password in this Section. Format is up to 32 ASCII characters. [224] Cellular Test Transmission Time of Day Default (9999) Enter a 4 digit value using the 24-hour clock format (HHMM) to set the test transmission time of day. Valid range: 00-23 for the hours (HH) and 00-59 for the minutes (MM). NOTE: To disable the test transmission time of day enter 9999 or FFFF in this Section. The internal date and time will be automatically programmed by the primary receiver only. [225] Cellular Test Transmission Cycle Default (000000) This value represents the interval in between test transmissions in minutes. Valid range: 000000 - 999999 minutes. Once the unit has sent the initial periodic test transmission, all future test transmissions will be offset by the programmed number of minutes. See Sections [026] - [029]. Table 13: Cellular Test Transmission Interval Test Transmission Interval Daily Programmed Minutes 001440 Weekly 010080 Monthly 043200 NOTE: Minimum value is 000005 minutes. Programming an interval that is less than 5 minutes will disable test transmission. [226] Cellular Trouble Delay Default (00) This option is used to program the delay, in minutes, for reporting a Cellular Trouble Delay. Valid entries are 00 - FF. (e.g., for a 10 minute Cellular Trouble Delay enter: 0A). There is no reporting delay if value is programmed as 00. 21 [227] Voice Call Timeout Default (00); This option sets the Voice Call Timeout, in minutes. Programming a value of 00 will disable timeout. Valid range is 00 to FF. [228] Voice Call Back Time Default (0A); This option sets the Voice call back time, in minutes. When the Communicator requests Call Back from the receiver, it will answer incoming calls during the programmed timeout period. If an incoming call is received after the timeout from requesting call back, the Communicator will answer the call and immediately hang up. Programming a value of 00 will disable timeout (accept all incoming calls). Default value is 0A/10 seconds. Valid range is 00 to FF. [229] Voice Call Back Number Default (SIM Telephone Number); This option sets the Voice Call Back Telephone Number for the receiver. This number is used for Two Way calling. Current SIM telephone number can be viewed in Section [996]. Valid entry is 32 character ASCII. Command and Control Options [301] Command and Control Toggle Options [1] SMS Notification Default (ON). [2] Reserved Default ( ). [3] SMS Command and Control Default (ON). [4] Reserved Default ( ). [5] SMS Character Format Default. ON: SMS Unicode, maximum message length is 70 characters. OFF: 7 bit SMS, maximum message length is 160 characters. [6] Long SMS Message Handling Default (OFF). ON: If longer than maximum message length, it is split and sent as multiple SMS messages. OFF: If longer than maximum message length, a single, truncated SMS message is sent. [7-8] Reserved Default ( ). [311] - [318] SMS Phone Number 1 - 8 Default ( ); These Sections may be programmed through DLS IV or the keypad. Up to 8 SMS telephone numbers (4 - 32 digits) can be programmed in Section [31x] Where x is an SMS telephone number from 1 to 8. Leaving programming blank for a telephone number will disable that number. The User can program their own mobile telephone numbers at the keypad using [*] [6] <> “SMS Programming”. The SMS Command and Control feature utilizes the SMS messaging service provided by the Cellular network and is subject to the limitations of SMS messaging. These limitations include delayed messages and lack of guaranteed delivery. NOTE: SMS Command and Control (Sections [601] - [618] will only process messages from the mobile telephone numbers programmed in this Section if SMS Command and Control is enabled [301][ 3] ON. SMS responses are listed in Sections [621] - [630]. A blank telephone number is disabled. SMS Command and Control Functions Users can send SMS text messages from their mobile phone to the communicator cellular phone number assigned to their system. Commands are only accepted from telephone numbers that have been programmed in Sections [311]- [318]. The system will reject messages sent from telephone numbers that are not on the programmed list. When the received SMS text matches a valid Section message, the function is performed on the control panel. Text messages are not case sensitive and extra spaces are ignored. A User Access Code may be required for some SMS messages. The User can send just the partition number or the complete label.(e.g., “Away arm Partition 2 1234” is treated the same as “away arm 2 1234”). The SMS Message format is in 3 parts: Command, Partition Label (or only the partition number), and Access Code. If an Access Code is included in the message, it is sent to the control panel for validation, along with the requested function. If the panel is configured to require an Access Code and the code is not sent (or invalid) the panel will fail the function (unsuccessful). If the panel fails the function, an SMS response message is sent to the user. The SMS response will echo the command sent, followed by the label “unsuccessful”. (e.g., “night arm partition 2 1234 unsuccessful”). The partition label or partition number may be excluded from the SMS request in a single partition system (e.g., disarm 9123). NOTE: The communicator cellular phone number can be viewed in Section [851], [996] and/or [851], [229] or by user entering [*][6], then scrolling down to ‘SMS Programming” and scrolling down to “Cellular phone No.” [<] [>] “Cellular Phone No.” at the keypad. An Access Code is required for all SMS commands, except Help. [601] Stay Arm Default (Stay Arm); 22 Send this command to the system to stay arm. It may be followed by a Partition Label or partition number and Access Code. [602] Away Arm Default (Away Arm); Send this command to the system to away arm. It may be followed by a Partition Label or partition number and Access Code. [603] Night Arm Default (Night Arm); Send this command to the system to night arm. It may be followed by a Partition Label or partition number and Access Code. [604] Disarm Default (Disarm); Send this command to the system to disarm. It may be followed by a Partition Label or partition number and Access Code. [605] - [608] Activate Command Output 1 - 4 Default (Activate Command Output n); Where n is a number from 1 - 4. Send this command to the system to activate a command output. It may be followed by a Partition Label or partition number and Access Code. [609] - [612] Deactivate Command Output 1 - 4 Default (Deactivate Command Output n); Where n is a number from 1 - 4. Send this command to the system to deactivate a command output. This command may be followed by a Partition Label or partition number and optional Access Code. [613] Bypass Default (Bypass); Send this command to the system to bypass a Zone. This command should be followed by a Zone label or Zone number and Access Code. [614] Unbypass Default (Unbypass); Send this command to the system to unbypass a Zone. This command should be followed by the Zone label or Zone number and Access Code. [615] Status Request Default (Status Request); Send this command to request the status of the system. It may be followed by a partition label or partition number and Access Code. If partition label is omitted, status of all enabled partitions will be sent. If there is a trouble on the system, the system label is sent, followed by the trouble label, then the partition status. NOTE: Status Request response may require more than one SMS message, depending on status of the system. There is a 10second delay between transmission of SMS messages. [616] Alarm Memory Request Default (Alarm Memory Request); Send this command to the system to request the alarm memory from the system. This command may be followed by a Partition Label or partition number, and Access Code. If partition label is omitted, alarm memory of all partitions will be sent. Alarm memory responses will include Partition label and Zone label. Up to 8 partitions may be contained in 1 message. NOTE: Alarm Memory Request response may require more than one SMS message, depending on alarm memory of the unit. There is a 10-second delay between transmission of SMS messages. [617] Help Default (Help); When help is sent, the SMS response is a listing of all interactive commands that can be sent to the module. Access Code is not required. [619] Keypad Message Default (Keypad Message); The response format is: [Account Label] [Date and Time] [SMS Function] [Response] [Message Text]. Fields are space delimited.When Keypad Message is sent, the SMS response is the message displayed on the keypad. If the message is too long to display on the keypad, only the portion displayed is sent in the response. SMS Command and Control Response NOTE: SMS Command and Control Response messages are up to 32 ASCII characters (Maximum 160 characters per SMS message). The message language is specified in Section [009]. SMS responses are sent to the phone that initiated the command. [621] Function Successful Default (Successful); 23 When an SMS Command and Control function is successfully performed by the panel, the successful label is included in the response sent to the user, following the command requested. (e.g., if “stay armed” command is completed by the panel, SMS response is: “stay armed successful”). [622] Function Unsuccessful Default (Unsuccessful); When an SMS Command and Control function is not successfully performed by the panel, the command sent to the unit will be included in the response sent to the user, followed by this label. (e.g., if “stay armed” command is not completed, SMS response is: “stay armed unsuccessful”). [623] Invalid Command Default (Invalid Command); This label will be included in the response message if the command was not accepted as a valid SMS command. [624] System Stay Armed Default (Stay Armed); This label will be included in the response to a status request command if a partition is stay armed. [625] System Away Armed Default (Away Armed); This label will be included in the response to a status request command if a partition is away armed. [626] System Night Armed Default (Night Armed); This label will be included in the response to a status request command if a partition is night armed. [627] System Disarmed Ready Default (Disarmed Ready); This label will be included in the response to a status request command if a partition is disarmed and is ready to arm. [628] System Disarmed Not Ready Default (Disarmed Not Ready); This label will be included in the response to a status request command if a partition is disarmed and is not ready to arm. [629] System is in Alarm Default (is in Alarm); This label will be included in the response to a status request command if a partition is in alarm. [630] Trouble Label Default (Service is Required); This label will be included in the response to the Alarm Memory command if there are no alarms in memory. [631] No Alarms in Memory Default (No Alarm Memory); This label will be included in the response to an Alarm Memory Request if there are no alarms on the system. [634] Error Code Default (Error Code); When an SMS initiated function fails, the module will send an error code to the telephone number that was source of the SMS request. Message format is: [Account Label] [Date and Time] [Error Code] [Error Type]. Fields are “space” delimited. Table 14: Error Code Format Class Definition Error Definition 01 Bad SMS format 02 Session failed due to local network issues 01 DLS 03 Unable to connect to remote server 04 Bad DLS access code 05 DLS lockout active 24 Class Definition Error Definition 01 Bad SMS format 02 Session failed due to local network issues 03 Unable to connect to remote server 02 TFTP 04 File not found on TFTP server 05 File not found on TFTP server 06 Update was unsuccessful 07 Update was successful Receiver Diagnostic Testing [901] Diagnostic Test Transmission [1] Ethernet 1 (OFF). [2] Ethernet 2 (OFF). [3] Cellular 1 (OFF). [4] Cellular 2 (OFF). [5],[6],[7],[8] Reserved (OFF). This Section may be used by the installer to force the Communicator to send an immediate test transmission to specific receivers, to verify that the communications paths are available. Diagnostic Test Transmission failure will indicate as FTC trouble (Yellow LED = 9 flashes). If an FTC error occurs when testing all receivers, select only one receiver and repeat test to isolate the receiver that is not communicating. System Information (Read Only) NOTE: Sections [987] - [998] are provided for information (Read Only). Values in these Sections can not be modified by the Installer. [987] Language Version This Section will display the current Language version of the Communicator. [988] DNS 1 IP Address This Section will display the IP address of DNS Server 1. This is useful when the unit is configured for DHCP and you need to see the IP address was assigned to the device by the DHCP Server. This value is programmed in Section [007] or assigned by DHCP. [989] DNS 2 IP Address This Section will display the IP address of DNS Server 2. This is useful when the unit is configured for DHCP and you need to see the IP address that was assigned to the device by the DHCP Server. This value is programmed in Section [008] or assigned by DHCP. [990] Boot Loader Version This Section will display the current Boot Loader version of the Communicator. [991] Firmware Version This Section will display the current firmware version of the device. Update worksheets with new version after a flash update is completed. [992] Ethernet IP Address This Section will display the IP address of the Ethernet connection. This value is programmed in Section [001] or assigned by DHCP. [993] Ethernet Gateway Address This Section will display the IP address of the Ethernet Gateway. This value is programmed in Section [003] or assigned by DHCP. [994] Cellular IP Address This Section will display the current dynamic IP address assigned by DHCP to the Cellular connection. NOTE: Cellular uses DHCP (Dynamic IP) only. The Cellular IP address is always provided by the Cellular network (i.e., not programmable). [995] SIM Number This Section will display the Subscriber Identity Module (SIM) number of the SIM card installed in the Communicator. Format is: Major Industry Identifier (2 digits) Mobile Country Code (2 or 3 digits); Mobile Network Code (2 - 3 digits); Unique Number (10 12 digits); and Checksum (1 digit). Valid SIM numbers range is: 18 - 21 numbers. This number is printed on SIM and the outside of the Communicator carton. NOTE: The Checksum digit is omitted on 19-digit SIM Card numbers. 25 [996] Cellular Telephone Number NOTE: This Section will display the Cellular telephone number of the SIM. This telephone number is required by the Installer for DLS and remote firmware (flash) update. User can access this telephone number by entering [*] [6] < > “Cellular Phone No.” to display the phone number. [997] IMEI Number This Section will display the unique 15- digit International Mobile Equipment Identity (IMEI) of the radio. Format is: Reporting Body Identifier (2 digits), Allocation Number (4 digits); Final Assembly Code (2 digits); Serial Number (6 digits); and a check digit. [998] MAC Address This Section will display the unique12-digit, hexadecimal number assigned as the Media Access Control (MAC) address of the device. System Reset Defaults [999] Software Default Default (99); The Software default allows the installer to refresh the unit after changes and also return the Communicator to the default state. 00: Default Module. All programming Sections in module revert to factory settings. This will erase all existing programming of the unit. 55: Reset. The Communicator is reset. This option is equivalent to power cycling the Communicator. Communicator Troubleshooting [984] Communicator Status The communicator status sections are intended to provide the installer with real-time status of the communicator’s functionality, operational readiness, failures, and potential malfunctions that may affect flawless operation of the communicator and its primary function of sending signal to the central station in case the monitored event occurs. The communicator status is displayed in the form of a 6- digit CODE (6 hexadecimal numbers) as in the following pattern: 00000F. The range of the code is from: 00000F – 2220CF. Not all numbers in this range are assigned a status code (Some numbers are skipped, i.e. not assigned the code). Each digit represents a status or trouble indicator (or assigned function when no trouble is present) as described below: 1. Digit 1 - Signal Indicator 1, displays the presence/strength of signal 1. 2. Digit 2 - Signal Indicator 2, displays the presence/strength of signal 2. 3. Digit 3 - Network Indicator, displays the presence (operational status) of network. 4. Digit 4 & 5 – TROUBLE INDICATOR displays the type of problem/malfunction on communicator or modules associated with and connected to communicator. 5. Digit 6 – Reserved for future use. For example, status code 11002F – when interpreted means: “Signal Indicator 1 OK, Signal indicator 2 OK, there is no network trouble, and there is trouble in the communicator, Panel supervision trouble.” For details see the table below: Table 15: Communicator Status and Trouble Coding in Hexadecimal Numbers Digit 1 Digit 2 Digit 3 Signal Indicator 1 Signal Indicator 2 Network Indicator Off Off Off On On On Flashing Flashing Flashing 26 00 01 02 03 04 05 06 07 08 09 0A 0B 0C Digits 4 & 5 Digit 6 TROUBLE INDICATOR Future Use Off (No trouble) Future use Panel supervision trouble Future use Lockout trouble 3G/Cellular trouble Ethernet Trouble Receiver Not Available Receiver Supervision trouble FTC Trouble C24 Configuration SMS Failure Future use Module configuration Trouble The communicator status codes will indicate the signal levels with digit 1 and 2, a network status with digit 3, and the trouble status with digit 4 and 5 as indicated in table above. For example status code 11000F would display following status: 1 – On = Signal indicator 1, is ON 1 – On = Signal indicator 2, is ON 0 – OFF = Network indicator, network is working 00 – TROUBLE INDICATOR = there is no trouble on the communicator. F – Future code not assigned yet. It is sixth hexadecimal digit. It could be also ‘ - ‘ (dash) instead of letter F (11000-). In this example both signal indicators are on indicating that communicator has excellent signal level; the network indicator is OFF showing that we do not have any network problems and trouble indicators are both OFF indicating that we don’t have any trouble on the communicator. [985] Radio Initialization Status The radio initialization status is intended to provide the installer with real-time status of radio communication. The radio initialization status is displayed in an 8 bit toggle option. Each digit indicates one task in the radio initialization process as follows: 1. Radio power up 2. Received the SMS from C24 3. Radio reset 4. Radio attached to network 5. Receiver 1 Initialized 6. Receiver 2 Initialized 7. Receiver 3 Initialized 8. Receiver 4 Initialize The following table shows each digit position in the status code, each digit’s value and its assigned meaning in the eight- digit code: Table 16: Radio Initialization Status - 1-8 bits completion Bit Not Completed Completed For example, the radio initialization status code 12-45--- indicates that Radio has been powered up, it has received SMS signal from C24, the radio is attached to the network, and Receiver 1 has been initialized. This code could be followed with...567 if Receivers 2, 3, and 4 are initialized where applicable. If the radio initialization status code does not indicate any problems, proceed with installation as per this manual. If troubles are reported, reset the initialization process. If this action does not fix the problem, refer to Trouble shooting section in this manual. Table 17: Trouble Code Indicators Trouble Indicator Possible Causes Digit 00 No Trouble 02 Panel Supervision Trouble 04 Lockout Trouble 05 3G/Cellular Trouble 06 Ethernet Trouble Trouble Possible Solutions N/A Check Section [382]Toggle Option[5] is ON (3G/Ethernet Module Enabled). Ensure the PC- LINK cable between the Panel and Communicator is connected properly (not reversed) and is securely in place. The SIM card has incorrect PIN programmed or has a PIN that the module does not recognize. Replace the SIM card. Confirm that 3G service is available and active in your area. Check all antenna connections. Ensure average radio signal strength is CSQ 6 or higher. (See Table 7). Ensure the SIM card is properly inserted into the SIM card holder. Ensure the SIM card has been activated. (Could take up to 24 hrs after install). If this trouble persists, relocate the Panel (and Communicator) or install an external antenna extension kit. Check with your ISP to confirm Internet service is active in your area. Ensure your Ethernet cable is securely inserted into the RJ45 jack of the Communicator and the Hub/Router/ Switch. Check that the link light on the Hub/Router/ Switch is ON. If link light is OFF, try restarting the Hub/Router/ Switch. If DHCP is used, ensure that the unit has an assigned IP address from the server. 27 Trouble Indicator Digit 07 08 09 0A 0C Possible Causes Trouble Possible Solutions In Section [851] [992] verify a valid IP address is programmed. If not, contact the Network administrator. If problem persists, replace the Ethernet cable and RJ45 connector. Ensure that the Ethernet path has internet connectivity. If you are using a static IP address make sure the gateway and subnet mask are entered correctly. If the network has a firewall, ensure the network has the programmed outgoing ports open (Default UDP Port 3060 and Port 3065). Receiver Not Available Ensure that all the receivers are programmed for DHCP or have the proper IP address and port number. Ensure the 3G Receiver APNs have been programmed with the Access Point Name provided by your 3G provider. This trouble is indicated when supervision is enabled and the unit is not able to successfully communicate with the receiver. Receiver Supervision Trouble If this trouble persists, contact your central station. The unit has exhausted all communications attempts to all programmed receivers for events generated by the Communicator. FTC Trouble Restart the system. If trouble persists, contact your dealer. The SIM is active but there is no programming for the Communicator. Ensure a profile has been programmed in Connect-24 for the SIM. Connect24 Configuration Failure You can confirm your programming by calling the Connect- 24 VRU, or by logging into the Connect24 VRU web site. This indication appears when Section [021] System Account Code, Section [101], [111], [201], and [211] Receiver Account Code have not been Module Configuration Trouble programmed. Ensure that a valid account code has been entered in these Sections. Communicator Troubleshooting The status code for the radio signal strength, its typical troubles, possible causes and troubleshooting instructions is displayed in the table below. Table 18: Radio Signal Strength Signal CSQ Signal Signal Signal Level Strength Level Indicator 1 Indicator 2 [dBm] Signal Level Status No Signal -108.8 bad 1 Bar 2 Bars 3 Bars 4 Bars 1-4 5-6 7 - 10 11 - 13 weak weak strong strong 5 Bars 14 + -108 ~ -103 -102 ~ -99 -98 ~ -91 -90 ~ -85 -84 and higher excellent Action Required Check all antenna connections. Confirm 3G service is active in area. Relocate Panel. Relocate Panel if signal strength shows less than 3 bars. Location is OK. 3G Signal Strength is greater than CSQ 7. The table below displays the Network indicator codes and meaning of each code. Table 19: Network indicator - Digit 3 Network indicator Value OFF ON Means No Network Trouble Ethernet Cable disconnected Ethernet DHCP failed Radio connection has been rest Radio IP failed 28 Network indicator Value Flashing Means Incoming transmission Connect 24 programming Outgoing transmission Incoming transmission 29 [011] Installer Code Default (CAFE) Valid range: 0000 - FFFF. Ethernet Cellular Programming Worksheets [012] DLS Incoming Port Default (0BF6/3062) Valid range: 0000 - FFFF. System Options [001] Ethernet IP Address Default (000.000.000.000) [013] DLS Outgoing Port Default (0BFA/3066) Valid range: 0000 - FFFF. [002] Ethernet IP Subnet Mask Default (255.255.255.000) [020] Time Zone Default (00) Valid range: 00 - 99. [003] Ethernet Gateway IP Address Default (000.000.000.000) [021] Account Code Default (FFFFFF) Valid range: 000001 - FFFFFE. [004] Receiver Supervision Interval Default (0087/135) Valid range: 0000 - FFFF. [022] Communications Format Default (04) Program 03 (CID), 04 (SIA). [005] System Toggle Options [1] Ethernet Receiver 1 Supervised Default (OFF). [023] Panel Absent Trouble Default (FF); Program 00 disable or FF enable. [2] Cellular Receiver 1 Supervised Default (OFF). [3] Supervision Type Default (OFF). [4] Primary Communications Path. [024] Panel Absent Trouble Restore Default (FF) Program 00 disable or FF enable. Default [OFF] TL2553G(R)-E; [ON] 3G2055(R)-E. [5] Redundant Communications Default (OFF). [025] Radio Activation Restore Default (FF) Program 00 disable or FF enable. [6] Remote Firmware Upgrade Default (ON). [7] Alternate Test Transmission Default (OFF). [8] Cellular Low Signal Trouble Default (OFF). System Test Options [006] System Toggle Options 2 [026] Ethernet 1 Transmission Default (FF) Program 00 disable or FF enable. [1] Ethernet Receiver 1 Enabled Default (ON). [2] Ethernet Receiver 2 Enabled Default (ON). [4] Cellular Receiver 1 Enabled Default (ON). [027] Ethernet 2 Transmission Default (00) Program 00 disable or FF enable. [5] Cellular Receiver 2 Enabled Default (ON). [7] DLS Over Cellular Default (ON). [028] Cellular 1 Transmission Default (FF) Program 00 disable or FF enable. [8] Interactive Over Cellular Default (ON). [007] DNS Server IP 1 Programming not permitted on UL/ULC listed system. Default (000.000.000.000) [029] Cellular 2 Transmission Default (00) Program 00 disable or FF enable. [008] DNS Server IP 2 [030] FTC Restore Default (FF) Program 00 disable or FF enable. Programming not permitted on UL/ULC listed system. Default (000.000.000.000) [031] Priority Tamper Alarm Default (FF) Program 00 disable or FF enable. Programming Options [010] System Toggle Options 3 [1] Enable 2-way audio over 3G 30 [032] Priority Tamper Restore Default (FF) Program 00 disable or FF enable. [113] Ethernet Receiver 2 Address Default (000.000.000.000) [033] Communicator Firmware Update Begin Default (FF) Program 00 disable or FF enable. [114] Ethernet Receiver 2 UDP Remote Port Default (0BF5/3061) Valid range: 0000 - FFFF. [034] Communicator Firmware Update Successful Default (FF) Program 00 disable or FF enable. [115] Ethernet Receiver 2 UDP Local Port Default (0BF9/3065) Valid range: 0000 -FFFF. [116] Ethernet Receiver 2 Domain Name Default ( ) Programming not permitted on UL/ULC listed system. ____________________________________ [035] Panel Firmware Update Begin Default (FF) Program 00 disable or FF enable. [036] Panel Firmware Update Successful Default (FF) Program 00 disable or FF enable. Ethernet Options [124] Ethernet Test Transmission Time Default (9999) Valid: 00-23(HH); 00-59(MM) [037] Panel Firmware Update Fail Default (FF) Program 00 disable or FF enable. [125] Ethernet Test Transmission Cycle Default (000000) Valid range: 000000 - 999999 minutes. Ethernet Receiver 1 Options [101] Ethernet Receiver 1 Account Code Default (0000000000) Valid range: 0000000001 - FFFFFFFFFE. Cellular Receiver 1 Options [102] Ethernet Receiver 1 DNIS Default (000000) Valid range: 000000 - FFFFFF. [201] Cellular Receiver 1 Account Code Default (0000000000) Valid range: 0000000001 - FFFFFFFFFE. [103] Ethernet Receiver 1 Address Default (127.000.000.001) [202] Cellular Receiver 1 DNIS Default (000000) Valid range: 000000 - 0FFFFF. [104] Ethernet Receiver 1 UDP Remote Port Default (0BF5/3061) Valid range: 0000 - FFFF. [203] Cellular Receiver 1 Address Default (000.000.000.000). Valid range: 000-255. [105] Ethernet Receiver 1 UDP Local Port Default (0BF4/3060)Valid range: 0000 - FFFF. [204] Cellular Receiver 1 Port Default (0BF5/3061) Valid range: 0000 - FFFF. [106] Ethernet Receiver 1 Domain Name Default ( ) 32 ASCII characters. Programming not permitted on UL/ULC listed system. ________________________________ [205] Cellular Receiver 1 APN Default ( ) 32 ASCII characters. ____________________________________ [206] Cellular Receiver 1 Domain Name Default ( ) 32 Character ASCII characters. ____________________________________ Ethernet Receiver 2 Options [111] Ethernet Receiver 2 Account Code Default (0000000000) Valid range: 0000000001 - FFFFFFFFFE. Cellular Receiver 2 Options [211] Cellular Receiver 2 Account Code Default (0000000000) Valid range: 0000000001 - FFFFFFFFFE. [112] Ethernet Receiver 2 DNIS Default (000000) Valid range: 000000 - 0FFFFF. 31 [212] Cellular Receiver 2 DNIS Default (000000) Valid range: 000000 - 0FFFFF. [7] Reserved [8] Reserved [311]-[318] SMS Phone Number 1-8 This section may be programmed through DLS- IV or the keypad. ______________________________________________ [213] Cellular Receiver 2 Address Default (000.000.000.000) Valid segment range: 000-255 [321]-[328] SMS Phone Number 1-8 Toggle Options [214] Cellular Receiver 2 Port Default (0BF5/3061) Valid range: 0000 - FFFF. [1] SMS Notification Alarm/Restore Default (OFF). [2] SMS Notification Tamper/Restore Default (OFF) [215] Cellular Receiver 2 APN Default ( ) 32 ASCII characters. ____________________________________ [216] Cellular Receiver 2 Domain Name Default ( ) 32 ASCII characters. Programming not permitted on UL/ULC listed system. ____________________________________ [3]SMSNotification Opening/ClosingDefault(OFF). [4] SMS Notification System Maintenance Default (OFF) [5] SMS Notification System Test Default (OFF) [6] SMS Notification Internal Events Default (OFF). [7] SMS Notification Enabled Default (OFF). Cellular Options [8] SMS Command and Control Enabled Default (ON). [221] Cellular Public Access Point Name Default ( ) 32 ASCII characters ____________________________________ [222] Cellular Login User Name Default ( ) 32 ASCII characters. ____________________________________ [223] Cellular Login Password Default ( ) 32 ASCII characters. ____________________________________ [224] Cellular Test Transmission Time of Day Default (9999) Valid range: 00 - 23 hrs. (HH) 00 - 59 min. (MM). [601] Stay Arm Default (Stay Arm) Send this command to the system to stay arm. ______________________________________________ [602] Away Arm Default (Away Arm) Send this command to the system to away arm. ______________________________________________ [603] Night Arm Default (Night Arm) Send this command to the system to night arm. ______________________________________________ [604] Disarm Default (Disarm) Send this command to the system to disarm. ______________________________________________ [605]-[608] Activate Command Output 1-4 Default (Activate Command Output n) Send this command to the system to activate a command output. ______________________________________________ [609]-[612] Deactivate Command Output 1-4 Default (Deactivate Command Output n) Send this command to the system to deactivate a command output. ______________________________________________ [613] Bypass Default (Bypass) Send this command to the system to bypass a zone. ______________________________________________ [614] Unbypass Default (Unbypass) Send this command to the system to unbypass a Zone. [225] Cellular Test Transmission Cycle Default (000000) Valid range: 000000 - 999999 minutes. [226] Network Trouble Delay Default (0F) Valid entries from, 00 to FF. Command and Control Options [301] Command and Control Toggle Options [1] Reserved [2] Reserved [3] SMS Command and Control Default (ON). [4] Reserved [5] SMS Character Format (OFF) [6] Long SMS Message Handling Default (OFF). 32 ______________________________________________ [615] Status Request Default (Status Request) Send this command to request the status of the system. ______________________________________________ [616] Alarm Memory Request Default (Alarm Memory Request) Send this command to request the alarm memory from the system. ______________________________________________ [617] Help Default (Help) Access Code is not required. ______________________________________________ [619] Keypad Message Default (Keypad Message) [Account Label] _________________________________ [Date and Time] _________________________________ [SMS Function] _________________________________ [Response] ____________________________________ [Message Text]_________________________________ [621] Function Successful Default (Successful) Example: “stay armed successful.” ______________________________________________ [622] Function Failure Default (Unsuccessful) Example: “stay armed unsuccessful.” ______________________________________________ [623] Invalid Command Default (Invalid Command) Unprogrammable, enter correct command. ______________________________________________ [624] System Stay Armed Default (Stay Armed) Included in the response message if the command was not accepted as a valid SMS command. ______________________________________________ [625] System Away Armed Default (Away Armed) Included in the response to a status request command if a partition is away armed. ______________________________________________ [626] System Night Armed Default (Night Armed) Included in the response to a status request command if a partition is night armed. ______________________________________________ [627] System Disarmed Ready Default (Disarmed Ready) Included in the response to a status request command if a partition is disarmed and is ready to arm. ______________________________________________ [628] System Disarmed, Not Ready Default (Disarmed Not Ready) Included in the response to a status request command if a partition is disarmed and is not ready to arm. 33 ______________________________________________ [629] System In Alarm Default (is in Alarm) This label will be included in the response to an Alarm Memory Request if there are no alarms on the system ______________________________________________ [630] Trouble Label Default (Service is Required) Included in the response to the Alarm Memory command if there are no alarms in memory. ______________________________________________ [631] No Alarms in Memory Default (No Alarms in Memory) Included in the response to the Alarm Memory command if there are no alarms on the system. ______________________________________________ [634] Response Code Default (Response Code) Included in the response to an Alarm Memory Request if there are no alarms on the system ______________________________________________ Receiver Diagnostic Testing [901] Diagnostic Test Transmission [1] Ethernet 1 Default (OFF). [2] Ethernet 2 Default (OFF). [3] Cellular 1 Default (OFF). [4] Cellular 2 Default (OFF). System Information (Read Only) [988] DNS 1 IP Address [989] DNS 2 IP Address [991] Firmware Version [992] Ethernet IP Address [993] Ethernet Gateway Address [994] Cellular IP Address [995] SIM Number ____________________________________ [996] Cellular Telephone Number This number is required for DLS and Firmware upgrades. ____________________________________ [997] IMEI Number ____________________________________ Limited Warranty Termination - Without prejudice to any other rights, DSC may terminate this EULA if You fail to comply with the terms and conditions of this EULA. In such event, You must destroyallcopiesof the SOFTWAREPRODUCT and allof itscomponent parts. Trademarks - ThisEULA doesnot grant You anyrights in connection with any trademarksor service marksof DSC or itssuppliers. 3. COPYRIGHT Alltitle and intellectualpropertyrightsin and to the SOFTWAREPRODUCT (including but not limited to any images, photographs, and text incorporated into the SOFTWAREPRODUCT), the accompanying printed materials, and anycopies of the SOFTWARE PRODUCT, are owned by DSC or its suppliers. You may not copythe printed materialsaccompanying the SOFTWAREPRODUCT. Alltitle and intellectualpropertyrights in and to the content which maybe accessed through use of the SOFTWARE PRODUCT are the property of the respective content owner and maybe protected byapplicable copyright or other intellectualproperty lawsand treaties. This EULAgrants You no rights to use such content. All rights not expresslygranted under thisEULAare reserved byDSC and itssuppliers. EXPORT RESTRICTIONS- You agree that You will not export or re- export the SOFTWARE PRODUCT to any country, person, or entity subject to Canadian export restrictions. CHOICEOF LAW - This Software License Agreement isgoverned by the laws of the Province of Ontario, Canada. ARBITRATION - All disputes arising in connection with this Agreement shall be determined byfinaland binding arbitration in accordance with the Arbitration Act, and the partiesagree to be bound bythe arbitrator’sdecision. The place of arbitration shall be Toronto, Canada, and the language of the arbitration shall be English. [998] MAC Address System Reset Defaults [999] Software Default Default (99); Valid entries are 00 or 55 EULA IMPORTANT - READ CAREFULLY: DSC Software purchased with or without Productsand Componentsis copyrighted and ispurchased under the following license terms: ThisEnd- User License Agreement (“EULA”) isa legal agreement between You (the company, individual or entity who acquired the Software and any related Hardware) and Digital Security Controls, a division of Tyco Safety Products Canada Ltd. (“DSC”), the manufacturer of the integrated security systems and the developer of the software and any related products or components (“HARDWARE”) which You acquired. If the DSC software product (“SOFTWAREPRODUCT” or “SOFTWARE”) is intended to be accompanied by HARDWARE, and is NOT accompanied by new HARDWARE, You maynot use, copy or install the SOFTWARE PRODUCT. The SOFTWARE PRODUCT includes computer software, and may include associated media, printed materials, and “online” or electronicdocumentation. Anysoftware provided along with the SOFTWAREPRODUCT that is associated with a separate end-user license agreement islicensed to You under the terms of that license agreement. By installing, copying, downloading, storing, accessing or otherwise using the SOFTWAREPRODUCT, You agree unconditionallyto be bound by the terms of this EULA, even if this EULA is deemed to be a modification of any previous arrangement or contract. If You do not agree to the terms of thisEULA, DSC is unwilling to license the SOFTWAREPRODUCT to You, and You have no right to use it. LIMITED WARRANTY NO WARRANTY - DSC PROVIDES THE SOFTWARE “AS IS” WITHOUT WARRANTY. DSC DOES NOT WARRANT THAT THE SOFTWARE WILL MEET YOUR REQUIREMENTS OR THAT OPERATION OF THESOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE. CHANGES IN OPERATING ENVIRONMENT - DSC shallnot be responsible for problemscaused bychangesin the operating characteristicsof the HARDWARE, or for problems in the interaction of the SOFTWARE PRODUCT with non- DSCSOFTWAREor HARDWAREPRODUCTS. LIMITATION OF LIABILITY; WARRANTY REFLECTS ALLOCATION OF RISK - IN ANY EVENT, IF ANY STATUTE IMPLIES WARRANTIES OR CONDITIONS NOT STATED IN THIS LICENSE AGREEMENT, DSC’S ENTIRE LIABILITYUNDER ANYPROVISION OF THISLICENSEAGREEMENT SHALL BE LIMITED TO THE GREATER OF THE AMOUNT ACTUALLY PAID BY YOU TO LICENSE THE SOFTWARE PRODUCT AND FIVE CANADIAN DOLLARS (CAD$5.00). BECAUSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, THEABOVELIMITATION MAYNOT APPLYTO YOU. DISCLAIMER OF WARRANTIES - THISWARRANTYCONTAINSTHE ENTIRE WARRANTYAND SHALL BEIN LIEU OF ANYAND ALL OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED (INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE) AND OF ALL OTHER OBLIGATIONSOR LIABILITIESON THE PART OF DSC. DSC MAKES NO OTHER WARRANTIES. DSC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON PURPORTING TO ACT ON ITS BEHALF TO MOD8IFY OR TO CHANGE THIS WARRANTY, NOR TO ASSUME FOR IT ANY OTHER WARRANTY OR LIABILITY CONCERNING THIS SOFTWAREPRODUCT. EXCLUSIVE REMEDY AND LIMITATION OF WARRANTY - UNDER NO CIRCUMSTANCESSHALL DSC BE LIABLE FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT DAMAGES BASED UPON BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, STRICT LIABILITY, OR ANY OTHER LEGAL THEORY. SUCH DAMAGES INCLUDE, BUT ARE NOT LIMITED TO, LOSS OF PROFITS, LOSS OF THE SOFTWARE PRODUCT OR ANY ASSOCIATED EQUIPMENT, COST OF CAPITAL, COST OF SUBSTITUTE OR REPLACEMENT EQUIPMENT, FACILITIES OR SERVICES, DOWN TIME, PURCHASERS TIME, THE CLAIMS OF THIRD PARTIES, INCLUDING CUSTOMERS, AND INJURYTO PROPERTY. DSC recommendsthat the entire system be completelytested on a regular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electricaldisruption, it ispossible for thisSOFTWAREPRODUCT to fail to performasexpected. DigitalSecurityControlswarrantsthe originalpurchaser that for a period of twelve monthsfromthe date of purchase, the product shallbe free of defectsin materials and workmanship under normal use. During the warranty period, Digital SecurityControlsshall, at itsoption, repair or replace anydefective product upon return of the product to its factory, at no charge for labour and materials. Any replacement and/or repaired parts are warranted for the remainder of the original warranty or ninety (90) days, whichever is longer. The original purchaser must promptlynotifyDigitalSecurityControlsin writing that there isdefect in materialor workmanship, such written notice to be received in all eventsprior to expiration of the warranty period. There is absolutelyno warranty on software and all software products are sold as a user license under the terms of the software license agreement included with the product. The Customer assumesall SOFTWARE PRODUCT LICENSE The SOFTWARE PRODUCT is protected by copyright laws and international copyright treaties, as well as other intellectual property laws and treaties. The SOFTWAREPRODUCT islicensed, not sold. 1. GRANT OF LICENSE This EULA grants You the following rights: Software Installation and Use - For each license You acquire, You may have onlyone copyof the SOFTWAREPRODUCT installed. Storage/Network Use - The SOFTWARE PRODUCT may not be installed, accessed, displayed, run, shared or used concurrentlyon or from different computers, including a workstation, terminal or other digital electronic device (“Device”). In other words, if You have several workstations, You will have to acquire a license for each workstation where the SOFTWAREwillbe used. Backup Copy - You maymake back-up copies of the SOFTWARE PRODUCT, but You may onlyhave one copyper license installed at anygiven time. You may use the back-up copysolelyfor archivalpurposes. Except asexpresslyprovided in thisEULA, You maynot otherwise make copiesof the SOFTWARE PRODUCT, including the printed materialsaccompanying the SOFTWARE. 2. DESCRIPTION OF OTHER RIGHTSAND LIMITATIONS Limitations on Reverse Engineering, Decompilation and Disassembly You may not reverse engineer, decompile, or disassemble the SOFTWARE PRODUCT, except and only to the extent that such activityisexpressly permitted byapplicable law notwithstanding thislimitation. You may not make any changes or modifications to the Software, without the written permission of an officer of DSC. You may not remove any proprietarynotices, marksor labels fromthe Software Product. You shallinstitute reasonable measuresto ensure compliance with the termsand conditionsof thisEULA. Separation of Components - The SOFTWARE PRODUCT is licensed as a single product. Its component partsmay not be separated for use on more than one HARDWAREunit. Single INTEGRATED PRODUCT - If You acquired this SOFTWARE with HARDWARE, then the SOFTWAREPRODUCT is licensed with the HARDWARE asa single integrated product. In thiscase, the SOFTWAREPRODUCT may only be used with the HARDWAREasset forth in thisEULA. Rental - You may not rent, lease or lend the SOFTWAREPRODUCT. You may not make it available to othersor post it on a server or web site. Software Product Transfer - You maytransfer allof Your rightsunder thisEULA onlyas part of a permanent sale or transfer of the HARDWARE, provided You retain no copies, You transfer allof the SOFTWAREPRODUCT (including all component parts, the media and printed materials, any upgrades and this EULA), and provided the recipient agrees to the terms of thisEULA. If the SOFTWARE PRODUCT is an upgrade, anytransfer must also include all prior versions of the SOFTWAREPRODUCT. 34 responsibilityfor the proper selection, installation, operation and maintenance of anyproducts purchased from DSC. Custom productsare onlywarranted to the extent that theydo not function upon delivery. In such cases, DSC can replace or credit at itsoption. returning goodsto DigitalSecurityControlsmust first obtain an authorization number. Digital Security Controlswill not accept anyshipment whatsoever for which prior authorization hasnot been obtained. Products which Digital Security Controls determines to be repairable will be repaired and returned. A set fee which Digital Security Controls has predetermined and which maybe revised from time to time, willbe charged for each unit repaired. Productswhich Digital Security Controls determines not to be repairable will be replaced by the nearest equivalent product available at that time. The current market price of the replacement product will be charged for each replacement unit. International Warranty The warranty for internationalcustomers is the same as for any customer within Canada and the United States, with the exception that DigitalSecurity Controls shallnot be responsible for anycustomsfees, taxes, or VAT that maybe due. Warranty Procedure To obtain service under this warranty, please return the item(s) in question to the point of purchase. All authorized distributors and dealers have a warranty program. Anyone returning goods to Digital Security Controls must first obtain an authorization number. DigitalSecurityControlswillnot accept anyshipment whatsoever for which prior authorization hasnot been obtained. Regulatory Information MODIFICATION STATEMENT DigitalSecurity Controls has not approved any changes or modifications to this device bythe user. Anychangesor modificationscould void the user’sauthority to operate the equipment. Digital Security Controls n’approuve aucune modification apportée à l’appareil par l’utilisateur, quelle qu’en soit la nature. Tout changement ou modification peuvent annuler le droit d’utilisation de l’appareilpar l’utilisateur. Conditions to Void Warranty Thiswarrantyappliesonly to defectsin parts and workmanship relating to normal use. It doesnot cover: damage incurred in shipping or handling; damage caused bydisaster such asfire, flood, wind, earthquake or lightning; damage due to causesbeyond the controlof DigitalSecurityControlssuch asexcessive voltage, mechanicalshockor water damage; damage caused byunauthorized attachment, alterations, modificationsor foreign objects; damage caused byperipherals(unlesssuch peripheralswere supplied by DigitalSecurityControls); defectscaused byfailure to provide a suitable installation environment for the products; damage caused byuse of the productsfor purposesother than those for which it wasdesigned; damage fromimproper maintenance; damage arising out of anyother abuse, mishandling or improper application of the products. INTERFERENCE STATEMENT Thisdevice complieswith Part 15 of the FCC Rulesand IndustryCanada licenceexempt RSSstandard(s). Operation issubject to the following two conditions: (1) thisdevice maynot cause interference, and (2) thisdevice must accept any interference, including interference that may cause undesired operation of the device. Le présent appareilest conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. WIRELESS NOTICE Thisequipment complieswith FCC and IC radiation exposure limitsset forth for an uncontrolled environment. The antenna should be installed and operated with minimumdistance of 20 cmbetween the radiator and your body. Antenna gain must be below: Frequency Band TL255GR-E, TL25535-E, 3G2055R-E, 3G2055-E GSM850 / FDD V 6.69 dBi PCS1900 / FDD II 9.31 dBi Thistransmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Cet appareil est conforme aux limites d'exposition aux rayonnements de la IC pour un environnement non contrôlé. L'antenne doit être installé de façon à garder une distance minimale de 20 centimètres entre la source de rayonnementset votre corps. Gain de l'antenne doit être ci-dessous: Bande de fréquence TL255GR-E, TL25535-E, 3G2055R-E, 3G2055-E GSM850 / FDD V 6.69 dBi PCS1900 / FDD II 9.31 dBi L'émetteur ne doit pasêtre colocalisé ni fonctionner conjointement avecà autre antenne ou autre émetteur. Items Not Covered by Warranty In addition to the itemswhich void the Warranty, the following itemsshall not be covered byWarranty: (i) freight cost to the repair centre; (ii) productswhich are not identified with DSC'sproduct labeland lot number or serial number; (iii) products disassembled or repaired in such a manner asto adverselyaffect performance or prevent adequate inspection or testing to verifyany warrantyclaim. Access cards or tags returned for replacement under warranty will be credited or replaced at DSC'soption. Productsnot covered bythiswarranty, or otherwise out of warranty due to age, misuse, or damage shall be evaluated, and a repair estimate shall be provided. No repair workwill be performed untila valid purchase order is received from the Customer and a Return Merchandise Authorisation number (RMA) is issued byDSC'sCustomer Service. DigitalSecurity Controls’s liability for failure to repair the product under this warrantyafter a reasonable number of attemptswillbe limited to a replacement of the product, asthe exclusive remedyfor breach of warranty. Under no circumstances shallDigitalSecurityControlsbe liable for anyspecial, incidental, or consequential damagesbased upon breach of warranty, breach of contract, negligence, strict liability, or any other legaltheory. Such damages include, but are not limited to, lossof profits, loss of the product or any associated equipment, cost of capital, cost of substitute or replacement equipment, facilitiesor services, down time, purchaser’stime, the claimsof third parties, including customers, and injury to property. The laws of some jurisdictions limit or do not allow the disclaimer of consequentialdamages. If the laws of such a jurisdiction apply to any claimby or against DSC, the limitations and disclaimers contained here shall be to the greatest extent permitted bylaw. Some statesdo not allow the exclusion or limitation of incidental or consequential damages, so that the above maynot apply to you. FCC CLASS B DIGITAL DEVICE NOTICE Thisequipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to part 15 of the FCC Rules. These limitsare designed to provide reasonable protection against harmfulinterference in a residential installation. This equipment generatesuses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, maycause harmfulinterference to radio communications. However, there is no guarantee that interference willnot occur in a particular installation. If thisequipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference byone or more of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different fromthat to which the receiver isconnected. •Consult the dealer or an experienced radio/TVtechnician for help CAN ICES-3 (B) / NMB-3 (B) FCC ID:F5315TL2553GRE Disclaimer of Warranties This warranty contains the entire warranty and shall be in lieu of any and all other warranties, whether expressed or implied (including all implied warranties of merchantability or fitness for a particular purpose) And of all other obligations or liabilities on the part of Digital Security Controls Digital Security Controls neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. This disclaimer of warranties and limited warranty are governed by the laws of the province of Ontario, Canada. DigitalSecurityControlsrecommendsthat the entire systembe completely tested on a regular basis. However, despite frequent testing, and due to, but not limited to, criminaltampering or electrical disruption, it ispossible for thisproduct to fail to performasexpected. Industry Canada Compliance Statement ThisEquipment meetsthe applicable IndustryCanada TerminalEquipment Technical Specifications. This is confirmed by the registration number. The abbreviation, IC, before the registration number signifies that registration was performed based on a Declaration of Conformityindicating that IndustryCanada technical specifications were met. It does not imply that that Industry Canada approved the equipment. The Ringer Equivalence Number (REN) for this terminalequipment is 0.0. The REN assigned to each terminalequipment provides an indication of the maximumnumber of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any Installer’s Lockout Anyproductsreturned to DSC which have the Installer’sLockout option enabled and exhibit no other problemswillbe subject to a service charge. Out of Warranty Repairs DigitalSecurityControlswillat itsoption repair or replace out-of-warrantyproducts which are returned to its factory according to the following conditions. Anyone 35 combination of devicessubject onlyto the requirement that the sumof the Ringer Equivalence Numbersof alldevicesdoesnot exceed 5. IC:160A-TL2553GRE Cet équipement est conforme aux spécifications techniques applicables aux équipements terminaux d'Industrie Canada. Ceci est confirmé par le numéro d'enregistrement. L'abréviation IC précédant le numéro d'enregistrement signifie que l'enregistrement a été effectué sur la base de la Déclaration de conformité indiquant que le produit est conforme aux spécifications techniques d'Industrie Canada. Ceci n'implique pas que le produit ait été approuvé par Industrie Canada. Le nombre équivalent de sonneries (REN) de cet appareil terminal est 0.0. Le REN attribué à chaque équipement terminalfournit une indication sur le nombre maximumde terminaux pouvant être connectés sur une interface téléphonique. La terminaison sur une interface peut constituer en n'importe quelle combinaison d'appareils, à la condition seulement que la somme desNombreséquivalents de sonneriesde touslesappareilsne soit passupérieure à 5. This Class B digital apparatus meets all requirements of the Canadian interference-causing equipment regulations. Cet appareilnumérique de la Classe B respecte touteslesexigencesde règlement sur le matérielbrouilleur du Canada. The term “IC:” before the radio certification number only signifies that Industry Canada technicalspecificationswere met. NIST Validation of encryption algorithmAES128 certificate No. 3161 36 © 2015 Tyco Security Products. All Rights Reserved. Tech Support: 1-800-387-3630 (Canada & U.S.) or 905-760-3000 www.dsc.com The trademarks, logos, and service marksdisplayed on thisdocument are registered in the United States[or other countries]. Anymisuse of the trademarksisstrictly prohibited and Tyco willaggressively enforce its intellectualproperty rightsto the fullest extent of the law, including pursuit of criminalprosecution wherever necessary. All trademarksnot owned byTyco are the propertyof their respective owners, and are used with permission or allowed under applicable laws. Product offeringsand specificationsare subject to change without notice. Actualproductsmayvaryfromphotos. Not allproductsinclude allfeatures. Availabilityvariesby region; contact your salesrepresentative. 5 37 38
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : luhandley Create Date : 2015:07:21 11:18:12-04:00 Modify Date : 2015:09:04 15:23:53+02:00 Subject : Has XFA : No Language : en-us XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : luhandley Description : Title : My Document Metadata Date : 2015:09:04 15:23:53+02:00 Keywords : Producer : madbuild Document ID : uuid:6facebc4-b685-44ff-a1d0-ba4496000f58 Instance ID : uuid:5981c06d-5265-48f1-a6f5-f17bf5a6d79b Page Layout : SinglePage Page Mode : UseOutlines Page Count : 38EXIF Metadata provided by EXIF.tools