Tyco Safety Sensormatic UMADSNE Ultra Max Advanced Digital System User Manual Power pack install guide

Tyco Safety Products/Sensormatic Ultra Max Advanced Digital System Power pack install guide

Power pack install guide

Download: Tyco Safety Sensormatic UMADSNE Ultra Max Advanced Digital System User Manual Power pack install guide
Mirror Download [FCC.gov]Tyco Safety Sensormatic UMADSNE Ultra Max Advanced Digital System User Manual Power pack install guide
Document ID105252
Application IDav6ufa7pgJ1sQiLdHUSKiQ==
Document DescriptionPower pack install guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatMicrosoft Word - pdf
Filesize12.33kB (154113 bits)
Date Submitted2000-06-16 00:00:00
Date Available2000-06-23 00:00:00
Creation Date2000-06-16 15:56:50
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2000-06-16 15:56:52
Document TitlePower pack install guide

Installation Guide
WORLD LEADER IN ELECTRONIC SECURI TY
ADS 216 Power Pack
About this Guide
This installation guide explains how to install the
ADS 216 Power Pack. Other related documents
are:
• Planning Guide, 8000-2693-01
• Installation Guide, ADS Pro•Max Pedestals,
8000-2693-03
• Installation Guide, ADS Floor•Max Antennas,
8000-2693-03
• Setup and Service Guide, 8000-2693-xx
• Reference Guide, 8000-2693-xx
Note: Because placement of system components
depends on architectural and customer requirements, your Sensormatic representative will supply
this information separately.
Contents
If you need assistance...
Call Sensormatic Customer Support at:
About this Guide................................................ 1
1-800-543-9740
Limitation of Warranty........................................ 1
Power Pack Overview........................................ 2
Installation Requirements................................... 2
Installing the Power Pack................................... 3
Connecting the Alarm Cable............................... 4
Connecting Power to the Power Pack................. 5
Specifications.................................................... 7
Declarations...................................................... 8
PRELIMINARY – 01/05/00
Limitation of Warranty
Any deviations from the materials or procedures
specified herein shall void Sensormatic's warranty
with the owner/buyer. In no event shall Sensormatic be liable for loss or damage caused by the
use of materials or procedures that do not meet
Sensormatic's specifications.
Ultra•Max, Sensormatic, and the Sensormatic logo are
registered trademarks of Sensormatic Electronics Corporation.
Other product names (if any) mentioned herein may be
trademarks or registered trademarks of other companies.
No part of this guide may be reproduced in any form without
written permission from Sensormatic Electronics Corporation.
© Copyright 2000. All rights reserved.
DOJ 01/00
8000-2693-02, Rev. A (8 pages)
ULTRA•MAX PRODUCTS
Power Pack Overview
Installation Requirements
The ADS 216 Power Pack is part of an Ultra•Max
security label detector. The power pack controls
up to two transceiver antennas and two remote
alarms.
Verifying Equipment and
Unpacking
Figure 1. Ultra•Max Detector
Power
pack
Antennas
Optional
remote
alarm
❑ Verify that all equipment has arrived. Make
sure the system configuration is the right one
for the installation site.
❑ Unpack major components in a back room. At
the install site, lay out parts in the order you will
need them. Do not clutter the aisle or cause a
trip hazard.
Installer/Contractor
❑ Shall have electrical work comply with the
latest national electrical code, national fire
code, and all applicable local codes and
ordinances.
❑ Shall coordinate all work with other trades to
avoid interference.
❑ Shall verify existing site conditions and
coordinate with the owner’s representative and
appropriate utilities as required.
❑ Shall obtain copies of all related plans,
specifications, shop drawings and addenda to
schedule and coordinate related work.
The ADS 216 Power Pack, ZEADS216 (NonEuropean) ships with the antennas or can be
ordered separately.
❑ Shall thoroughly review the project to ensure
that all work meets or exceeds the above
requirements. Any alleged discrepancies shall
be brought to the attention of Sensormatic
Electronics.
WARNING!
Do not install this product in hazardous
areas where highly combustible or
explosive products are stored or used.
Electrical Requirements
❑ Connect the pack to a 100-120Vac or 220240Vac source. No fuse exchange is required
for the power pack.
❑ The ac source must be unswitched with less
than 0.5Vac between neutral and ground.
❑ DO NOT share the ac source with neon signs,
motors, computers, cash registers, terminals,
or data communications equipment.
❑ DO NOT use orange-colored outlets dedicated
for computer equipment.
INSTALLATION GUIDE
ADS 216 POWER PACK
8000-2693-02, REV. A
Power Pack
❑ The pack can be placed on a shelf or mounted
on a wall. The pack can be hidden in a remote
location such as checkout counter, back room,
or basement.
❑ Provide a minimum of 20cm (8") of
unobstructed space around the pack for
ventilation.
❑ Use the appropriate power cord based on the
country of use.
USA-IEC 320, 18/3, 125V, 10A, 7.5ft.
0351-0547-01
Schuko-IEC 320, 1mm sq., 250V, 10A, 2.5m
0351-0547-02
UK-IEC 320, 1mm sq., 250V, 10A, 2.5m
0351-0547-03
Japan-IEC 320, 2mm sq., 250V, 15A, 2.5m
0351-0547-04
US-Filter, Line, 125V, 6A, Plug-in
0351-0547-05
Australia to IEC 320, 2.5m, 250V, 10A
0351-0547-07
❑ Replace the pack’s slow-blow fuses only with a
fuse of the same type and rating.
❑ Maximum cable distance from the antennas to
the power pack is 12.2m (40').
ZC30-XP/ZC35-XP
Remote Alarm Unit (if used)
❑ Plug the transformer used to power the alarm
into a 24-hour, unswitched outlet.
❑ Maximum cable distance from the power pack
to each alarm unit is about 7.6m (25').
Tools and Equipment Required
Installing the Power Pack
The pack can rest on a shelf (no mounting
procedure required) or can be hung on a wall.
To mount the pack on a wall, proceed to the
section “Wall-mounting the Power Pack” on
page 3.
Otherwise, go to “Connecting the Alarm Cable”
on page 4.
Wall-mounting the Power Pack
1. Attach the bracket to the wall (Figure 2).
The pack can be mounted on studs using
screws or on wall-board using screws and
anchors.
a. Position wall-mount bracket and level it to
mark the mounting hole locations. Remove
the bracket.
b. If mounting on wall-board, drill four holes
for hollow wall (wall-board) anchors. Tap
anchors (not shown) into holes.
c.
With its lip facing upward, secure the
bracket to the wall with four screws. The
screws are suitable for use in wood or
metal.
Figure 2. Attaching the bracket to the wall
For all system installations:
• 6 mil (minimum) plastic sheeting (to protect
nearby items from dust)
• Permanent marker and/or pencil
• Hammer drill with 6.5mm (1/4") and 9.6mm
(3/8") masonry drill bits
• Power drill with 1.6mm (1/16"), 6.5mm (1/4"),
and 9.6mm (3/8") drill bits
• Hammer
• Phillips and slotted screwdrivers
• Ratchet and socket set
• Vacuum and broom
ADS 216 POWER PACK
8000-2693-02, Rev. A
INSTALLATION GUIDE
2. If using conduit, attach conduit to bracket.
The power pack bracket provides ten ½" or ¾"
knockouts for antenna and alarm cables and
one ½” or ¾” knockout for hardwired AC power.
Refer to Figure 6.
Antenna Tx/Rx and Com cables attach to
connectors in the lower corner of the power
pack. The remote alarm cable attaches to a
connector above the antenna cable connectors.
Select knockouts closest to the power pack
connectors for the cables and attach conduit.
Maximum conduit attachment is shown in
Figure 3. Several cables can share conduit as
long as conduit fill does not exceed 50 percent.
Connecting the Alarm Cable
The power pack can trigger up to two remote
alarms.
To connect remote alarms, continue.
Otherwise, go to “Connecting Power to the
Power Pack” on page 5.
Connect the remote alarm to the Relay A-B alarm
receptacle of the power pack (Figure 6).
Relay A-B pin assignments are as follows:
Pin
Relay Output
Relay A Arm
Relay B N.C.
Relay C N.O.
Alarm
Shield
RS485
Not used
Relay B Arm.
Relay B N.C.
Relay B N.O.
Shield
Figure 3. Maximum conduit attachment
Noise Coil
A and B
Option
SkyMax A and B
Relay A-B
Antenna A and B
For example, connect the remote alarm controlled
by relay 1 to pins 1, 2, and 3. Refer to Figure 4 for
remote alarm wiring.
Figure 4. Remote alarm wiring
AC power
Transformer
Pin 1 - black
Pin 4 - red
Pin 2 - green
Pin 3 - white
3. Mount the pack to the bracket.
a. Rest the lip of the pack’s mounting bracket
on the lip of the wall-mounted bracket.
b. Slide pack to left until pack butts up against
wall-mounted bracket.
4. After cable connections are complete,
attach bracket to power pack using two
screws at each end of bracket.
COM
17V
Remote
alarm
(ZC30/ZC35)
Relay
A-B
pin 1 pin 3
or
pin 6 pin 8
Mounting the power pack is complete. Go to
“Connecting the Alarm Cable” on page 4.
INSTALLATION GUIDE
ADS 216 POWER PACK
8000-2693-02, REV. A
Connecting Power to the
Power Pack
For installation using a line cord, the
socket-outlet must be installed near
the equipment and at a location which
is easily accessible.
Für Installationen mit einem
Stromkabel muß die Steckdose an
einem Standort installiert werden,
welcher einfachen Zugang erlaubt.
The AC power source can be 100-120Vac or 220240Vac. The power supply automatically senses
the voltage so no jumper settings are required.
AC power can be hardwired to the power pack or
connected by an ac power cord.
WARNING—RISK OF ELECTRIC
SHOCK!
The AC power line could be carrying
120Vac or 240Vac.
If ac power is connected by a power cord, remove
the metal cover over the IEC connector (Figure 6)
and attach the power cord.
If ac power is hardwired, do the following:
A 6A, 2 pole, ganged disconnect
device, which also provides short
circuit and overload protection, and
has a minimum 3mm open circuit
clearance, in accordance with the
National Electric Code and applicable
local codes must be installed by a
licensed electrician at a location
readily accessible to the equipment.
Ein 6A, 2-poliges, gekoppeltes Ausschaltgerät, welches auch über einen
Kurzschluß- sowie Überbelastungsschutz
verfügt, und einen minimum 3mm offenen
Schaltabstand aufweist, nach
Übereinstimmung mit den Nationalen
Elektrischen Regelungen sowie lokalen
Regeln, muß an einem Standort installiert
werden, welcher einfachen Zugang zum
Gerät erlaubt.
1. Route power cable through knockout on
corner of power pack (Figure 6).
2. Using a small screwdriver, connect the ac
power wires (line, neutral) to the two-pin
connector in terminal P2. Connect white to
pin 1 (neutral); connect black to pin 2 (line).
Refer to Figure 5.
3. Plug the two-pin connector into pluggable
terminal P2 on the backplane board.
4. Connect green to ground on the power pack
chassis.
Figure 5. Hardwired AC power connection
AC ground (green)
Hardwired AC:
P2: pin 1 – neutral (white)
P2: pin 2 – line (black)
Backplane
board
ADS 216 POWER PACK
8000-2693-02, Rev. A
INSTALLATION GUIDE
Figure 6. Power pack connections
Remote alarm
connector
P10
P8
P14
ADS RS485 Noise
Coil B
Alarm
Antenna
connectors
P11
P13
P4
P6
P5
P12
P7
P18
P17
P9
Noise Option Option Option Ferrite Relay Com Tx/Rx Com Tx/Rx
A-B Ped. B Ped. B Ped. A Ped. A
Coil A
ADS Power Pack
Relay A-B
ARM B
NC B
NO B
SHLD
ARM A
NC A
NO A
SHLD
1 2 3 4 5 6 7 8 9 10
IEC connector cover
Bracket to pack
mounting screws
(two at each end)
Knockout for hardwired AC
INSTALLATION GUIDE
ADS 216 POWER PACK
8000-2693-02, REV. A
Environmental
Specifications
Ambient Temperature:.......0°C to 50°C
(32°F to 122°F)
Electrical
Relative Humidity: .............0 to 90%
non-condensing
Power Supply (Non-European Power Pack)
Primary Input: ...................100-120Vac or
220-240Vac
@ 50–60Hz
Mechanical
Primary Power Fuse: .........5A, 250V slo-blow
Power Pack
Length..............................50.7cm (20")
Current Draw: ...................2.0A peak
Width with bracket.............37.7cm (14.8")
Input Power: .....................<180W
Width without bracket ........32.6cm (12.8")
Transmitter
Outputs:............................2 ports (two antennas,
multiplexed)
Operating Frequency: ........58, 60, or 68kHz
(±200Hz)
Transmit Burst Duration.....1.6ms
Height ..............................15cm (5.9")
Weight..............................kg (lbs.)
Remote Alarm / Message Unit
Height ..............................20.3cm (8")
Length..............................15cm (5.9")
Width................................6.4cm (2.5")
Transmit Current: ..............16A peak
Burst Repetition Rate:
Based on 50Hz ac.............37.5Hz (Normal)
75Hz (Validation)
Based on 60Hz ac.............45Hz (Normal)
90Hz (Validation)
Receiver
Inputs: ..............................2 ports (two antennas,
multiplexed)
Center Frequency:.............58, 60, or 68kHz
Receive Coil Resistance: ...1.6 ohms (±5%)
Alarm
Alarm Relay Output ...........DPDT contacts
Contact Switching Current .1.0A max.
Contact Switching Voltage .28V max.
Lamp/Audio Duration.........1–30 sec.
(1 sec. increments)
ADS 216 POWER PACK
8000-2693-02, Rev. A
INSTALLATION GUIDE
Declarations
Regulatory Compliance (NonEuropean Power Pack)
Safety:............................ UL 1950
Can/CSA C22.2
No. 950
EMC:.............................. 47 CFR, Part 15
FCC COMPLIANCE: This equipment complies with Part
15 of the FCC rules for intentional radiators and Class A
digital devices when installed and used in accordance with the
instruction manual. Following these rules provides reasonable
protection against harmful interference from equipment
operated in a commercial area. This equipment should not be
installed in a residential area as it can radiate radio frequency
energy that could interfere with radio communications, a
situation the user would have to fix at their own expense.
EQUIPMENT MODIFICATION CAUTION: Equipment
changes or modifications not expressly approved by
Sensormatic Electronics Corporation, the party responsible for
FCC compliance, could void the user's authority to operate the
equipment and could create a hazardous condition.
Other Declarations
WARRANTY DISCLAIMER: Sensormatic Electronics
Corporation makes no representation or warranty with respect
to the contents hereof and specifically disclaims any implied
warranties of merchantability or fitness for any particular
purpose. Further, Sensormatic Electronics Corporation
reserves the right to revise this publication and make changes
from time to time in the content hereof without obligation of
Sensormatic Electronics Corporation to notify any person of
such revision or changes.
LIMITED RIGHTS NOTICE: For units of the Department
of Defense, all documentation and manuals were developed at
private expense and no part of it was developed using
Government Funds. The restrictions governing the use and
disclosure of technical data marked with this legend are set
forth in the definition of "limited rights" in paragraph (a) (15)
of the clause of DFARS 252.227.7013. Unpublished - rights
reserved under the Copyright Laws of the United States.
INSTALLATION GUIDE
ADS 216 POWER PACK
8000-2693-02, REV. A

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2000:06:16 15:56:50
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2000:06:16 15:56:52-04:00
Page Count                      : 8
EXIF Metadata provided by EXIF.tools
FCC ID Filing: BVCUMADSNE

Navigation menu