Tyco Safety Sensormatic UMADSNE Ultra Max Advanced Digital System User Manual pedestal install guide

Tyco Safety Products/Sensormatic Ultra Max Advanced Digital System pedestal install guide

pedestal install guide

Download: Tyco Safety Sensormatic UMADSNE Ultra Max Advanced Digital System User Manual pedestal install guide
Mirror Download [FCC.gov]Tyco Safety Sensormatic UMADSNE Ultra Max Advanced Digital System User Manual pedestal install guide
Document ID105253
Application IDav6ufa7pgJ1sQiLdHUSKiQ==
Document Descriptionpedestal install guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatMicrosoft Word - pdf
Filesize13.68kB (171009 bits)
Date Submitted2000-06-16 00:00:00
Date Available2000-06-23 00:00:00
Creation Date2000-06-16 15:59:22
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2000-06-16 15:59:24
Document Titlepedestal install guide

Installation Guide
WORLD LEADER IN ELECTRONIC SECURI TY
ADS Pro•Max
Pedestals
(Alpha I Version)
About this Guide
This installation guide explains how to install ADS
™
Pro•Max pedestals. Other related documents
are:
• Planning Guide, 8000-2693-01
• Installation Guide, ADS 216 Power Pack, 80002693-02
• Setup and Service Guide, 8000-2693-xx
• Reference Guide, 8000-2693-xx
Note: Because the placement of antenna
components can vary depending on architectural
and customer requirements, your Sensormatic
representative will supply this information
separately.
If you need assistance...
Call Sensormatic Customer Support at:
1-800-543-9740
Limitation of Warranty
Contents
About this Guide................................................ 1
Limitation of Warranty........................................ 1
Pedestal Overview ............................................ 2
Component Part Numbers ................................. 2
Installation Requirements................................... 4
Installing ADS Pro•Max Pedestals ...................... 5
Specifications.................................................... 9
Declarations.................................................... 10
Any deviations from the materials or procedures
specified herein shall void Sensormatic’s warranty
with the owner/buyer. In no event shall Sensormatic be liable for loss or damage caused by the
use of materials or procedures that do not meet
Sensormatic’s specifications.
Ultra•Max, Sensormatic, and the Sensormatic logo are
registered trademarks and Pro•Max is a trademark of
Sensormatic Electronics Corporation. Other product names (if
any) mentioned herein may be trademarks or registered
trademarks of other companies.
No part of this guide may be reproduced in any form without
written permission from Sensormatic Electronics Corporation.
© Copyright 2000. All rights reserved.
DOJ 01/00
PRELIMINARY 01/05/00
8000-2693-03, Rev. A (10 pages)
ULTRA•MAX PRODUCTS
Component Part Numbers
Pedestal Overview
®
ADS Pro•Max pedestals are part of an Ultra•Max
security label detector that deters theft. One or two
ADS Pro•Max pedestals are attached to a power
pack. Pedestals are positioned opposite each
other at an exit.
CAUTION: Space pedestals no more than 2.4m
(9') apart.
Figure 1. ADS Pro•Max Detector
Power
pack
ADS Pro•Max Pedestal System, Single –
xxxxxxxx
− One ADS Pro•Max Pedestal
(0300-2302-01)
− One Power Pack (ZEADS216)
− One Power Cord Option (0351-0547-xx)
ADS Pro•Max Pedestal System, Dual –
xxxxxxxx
− Two ADS Pro•Max Pedestals
(0300-2302-01)
− One Power Pack (ZEADS216)
− One Power Cord Option (0351-0547-xx)
Optional
remote
alarm
Pedestals
INSTALLATION GUIDE
ADS PRO•MAX PEDESTALS
8000-2693-03, REV. A
Figure 2. Wiring diagram
Pedestal B
Pedestal A
P1
BLK
RED
GRN
WHT
SHLD
1 2 3 4 5
P6
P6
BLK
BRN
RED
ORG
YEL
GRN
BLU
VIO
GRY
SHLD
1 2 3 4 5 6 7 8 9 10
P1
P6
P1
Com Cable 0650-2220-01 (9 conductor)
Tx/Rx Cable 0650-2219-01 (4 conductor)
Tx/Rx Cable 0650-2219-01 (4 conductor)
Com Cable 0650-2220-01 (9 conductor)
P8
P14
P10
P9
P17
P18
P12
P11
P13
P7
P5
P6
P4
ADS RS485 Noise Noise Option Option Option Ferrite Relay Com Tx/Rx Com Tx/Rx
A-B Ped. B Ped. B Ped. A Ped. A
Alarm
Coil B Coil A
ADS Power Pack
Tx/Rx
Com
BLK
BRN
RED
ORG
YEL
GRN
BLU
VIO
GRY
SHLD
1 2 3 4 5 6 7 8 9 10
ADS PRO•MAX PEDESTALS
8000-2693-03, Rev. A
BLK
RED
GRN
WHT
SHLD
1 2 3 4 5
INSTALLATION GUIDE
Installation Requirements
Verifying Equipment and
Unpacking
❑ Verify that all equipment has arrived. Make
sure the system configuration is the right one
for the installation site.
❑ Unpack major components in a back room. At
the install site, lay out parts in the order you will
need them. Do not clutter the aisle or cause a
trip hazard.
Installer/Contractor
❑ Shall have electrical work comply with the
latest national electrical code, national fire
code, and all applicable local codes and
ordinances.
❑ Shall coordinate all work with other trades to
avoid interference.
❑ Shall verify existing site conditions and
coordinate with the owner’s representative and
appropriate utilities as required.
❑ Shall obtain copies of all related plans,
specifications, shop drawings and addenda to
schedule and coordinate related work.
❑ Shall thoroughly review the project to ensure
that all work meets or exceeds the above
requirements. Any alleged discrepancies shall
be brought to the attention of Sensormatic
Electronics.
Antenna Placement and Cabling
❑ Whenever possible, keep the pedestals at least
2.4m (8') away from noise sources such as
computer monitors, TV’s, switching power
supplies, and neon displays.
❑ Do not position pedestals more than 2.7m (9')
apart.
❑ Maximum cable distance from the pedestals to
the power pack is 12.2m (40').
Tools and Equipment Required
For all ADS Pro•Max installations:
• 6 mil (minimum) plastic sheeting (to protect
nearby items from dust)
• Permanent marker and/or pencil
• Floor saw
• Hammer drill with 6.5mm (1/4") and 9.6mm
(3/8") masonry drill bits
• Power drill with 1.6mm (1/16"), 6.5mm (1/4"),
and 9.6mm (3/8") drill bits
• Hammer
• Phillips and slotted screwdrivers
• 14-16 AWG and 16-22 AWG wire strippers
• 2.4mm (.093") Molex extractor tool
• Ratchet and socket set
• Hand vacuum and broom
WARNING!
Do not install this product in hazardous
areas where highly combustible or
explosive products are stored or used.
INSTALLATION GUIDE
ADS PRO•MAX PEDESTALS
8000-2693-03, REV. A
Installing ADS Pro•Max
Pedestals
Figure 4. Cable entry points (circled)
1. Position ADS Pro•Max pedestals at exact
mounting location (Figure 3).
DO NOT space pedestals more than 2.7m (9')
apart.
Figure 3. Pedestal spacing
Ped. 1
Ped. 2
2.78m (9') max.
2. If you need to trench the floor between the
pedestals, do the following:
Using the floor saw and the appropriate blade,
trench the floor from pedestal to pedestal.
Trench depth is 1.5cm (3/4"); trench width is
.5cm (1/4"). Trench depth allows for .5cm (1/4")
of floor compound above the cable.
Make sure that the trench extends under the
pedestal location so cables can directly enter
the pedestal from underneath.
3. Route cables from pedestal to pack or pack
to pedestal.
A four conductor Tx/Rx cable (0650-2219-01)
and a nine conductor Com cable (0650-222001) attaches to each pedestal.
5. Remove capacitor board cover and route
Tx/Rx and Com cables up through base of
pedestal (Figure 5).
a. Remove screws holding capacitor board
cover in place and remove cover.
b. Push Tx/Rx cable up through channel in
base on left side of capacitor board.
c.
Push Com cable up through channel in
base on right side of capacitor board.
Figure 5. Cable routing in base
4. Prepare for cable entry (Figure 4).
Cables can enter the pedestal via a trench,
surface Wiremold or buried conduit. Cut the
shroud to fit the Wiremold if necessary.
Cap board
cover
Tx/Rx cable
channel
ADS PRO•MAX PEDESTALS
8000-2693-03, Rev. A
Com cable
channel
INSTALLATION GUIDE
6. Bolt the pedestal to the floor (Figure 6).
c.
a. Using the base holes as a template, mark
locations for four mounting holes.
b. Drill 9.6mm (3/8") holes to a depth of 7cm
(2.75") for each anchor. Tap an anchor into
each hole, leaving 2.5cm (1") of exposed
threads.
c.
Place the mounting holes over the four
protruding anchors. Secure the base to the
floor using anchor hardware provided.
Figure 6. Bolting down the pedestal
Using a small screwdriver, attach the Com
cable to connector 2109-0510-10 following
the color-coded label:
Pin 1 -
Black
Pin 2 -
Brown
Pin 3 -
Red
Pin 4 -
Orange
Pin 5 -
Yellow
Pin 6 -
Green
Pin 7 -
Blue
Pin 8 -
Violet
Pin 9 -
Gray
Pin 10 Shield
d. Insert connector 2109-0510-01 into
pluggable terminal block P6 on the
capacitor board.
8. Connect Tx/Rx cables (4 conductor) to the
power pack (Figure 2).
WARNING: Do NOT hot plug cables. Turn off
the power pack before connecting cables.
a. Install Romex-type connectors or conduit
fittings in knockouts on pack.
b. Route each Tx/Rx cable through knockout.
c.
Using a small screwdriver, attach Tx/Rx
cables to connectors 2109-0351-05
according to the following table:
7. For each pedestal, connect the Tx/Rx (4
conductor) and Com (9 conductor) cables to
the capacitor board. Refer to Figure 2 and
Figure 7.
Pin 1 -
Black
Pin 2 -
Red
Pin 3 -
Green
a. Using a small screwdriver, attach the
TX/Rx cable to connector 2109-0254-04
according to the following table:
Pin 4 -
White
Pin 1 -
Black
Pin 2 -
Red
Pin 3 -
Green
Pin 4 -
White
Pin 5 -
Shield
Pin 5 Shield
d. Insert Tx/Rx cable for pedestal A into
pluggable terminal block Tx/Rx A; insert
transmit cable for pedestal B into pluggable
terminal block Tx/Rx B.
b. Insert connector 2109-0254-04 into
pluggable terminal block P1 on the
capacitor board.
INSTALLATION GUIDE
ADS PRO•MAX PEDESTALS
8000-2693-03, REV. A
9. Connect Com cables (9 conductor) to the
power pack.
a. Install Romex-type connectors or conduit
fittings in knockouts on pack.
b. Route each Com cable through knockout.
c.
Using a small screwdriver, attach
connectors 2109-0510-10 to each Com
cable following the color-coded label.
Pin 1 -
Black
Pin 2 -
Brown
Pin 3 -
Red
Pin 4 -
Orange
Pin 5 -
Yellow
Pin 6 -
Green
Pin 7 -
Blue
Pin 8 -
Violet
Pin 9 -
Gray
Pin 10 -
Shield
d. Insert connectors into pluggable terminal
blocks on the power pack. Connect
pedestal A to Com A; connect pedestal B
to Com B.
CAUTION: Be sure the Tx/Rx and Com
cables for a pedestal are attached to
corresponding connectors. Incorrect
connections will cause incorrect alarm
signaling.
Proceed to Pedestal Tuning on page 8.
Figure 7. Capacitor board 0301-1532-01
Tuning jumpers
JW1 – JW14
Tuning jumper LEDs
DS1 – DS14
P1 –
Tx/Rx
Tx Off LED
ADS PRO•MAX PEDESTALS
8000-2693-03, Rev. A
Check
Tuning
button
P6 - Com
INSTALLATION GUIDE
Pedestal Tuning
6. Change the jumpers on the capacitor board
to the settings indicated by the yellow LEDs
on the capacitor board. Refer to Figure 7.
The pedestal is shipped with default settings that
are acceptable for most installations. However, the
pedestal may require tuning to adjust for
conditions at the installation site.
WARNING—RISK OF ELECTRIC
SHOCK!
The green Tx Off LED on the capacitor
board must be ON before changing
jumpers. It indicates there are no high
voltages on the board.
The pedestal is tuned by changing jumper settings
on the capacitor board in each pedestal. The
power pack assists tuning by lighting LEDs to
indicate the correct jumper settings.
To tune the pedestal, do the following for each
pedestal:
1. If necessary, turn off the power pack.
2. Access the capacitor board in the pedestal.
Refer to Figure 8.
3. Make sure the jumpers are set to the
defaults.
JW1 In (1-2)
JW2 -
Out (2-3)
JW3 -
In (1-2)
JW4 -
In (1-2)
JW5 -
In (1-2)
JW6 -
Out (2-3)
JW7 -
Out (2-3)
JW8 -
In (1-2)
JW9 -
Out (2-3)
JW10 -
In (1-2)
JW11 -
In (1-2)
JW12 -
In (1-2)
JW13 -
Out (2-3)
JW14 -
Out (2-3)
4. Turn on the power pack.
5. Check the green status LED on the
pedestal.
If the green status LED is ON continuously,
the pedestal is tuned and pedestal
installation is complete.
If a yellow jumper LED is on, place the
corresponding jumper in the 1-2 position.
If a yellow jumper LED is off, place the
corresponding jumper in the 2-3 position.
7. Press the Check Tuning button on the
capacitor board and return to step 5.
After repeating steps 5 and 6 several times, the
pedestal should be tuned with the green status
LED on continuously. If not, contact
Sensormatic Customer Service.
Figure 8. Pedestal features
Alarm light
Speaker
Status LED:
On – Normal
operation
Blinking –
Tuning required
Off – Power off
RS232 port
Transmit
inhibit
keyswitch
Capacitor board
(behind cover)
If the green status LED is blinking, the
pedestal needs tuning. Proceed to step 6.
INSTALLATION GUIDE
ADS PRO•MAX PEDESTALS
8000-2693-03, REV. A
Specifications
Environmental
Ambient Temperature:.......0°C to 50°C (32°F to
122°F)
Electrical
Relative Humidity: .............0 to 90% noncondensing
Power Supply (Non-European Power Pack)
Primary Input: ...................100-120Vac or
220-240Vac
@ 50–60Hz
Mechanical
Height ..............................164cm (64 ½”)
Primary Power Fuse: .........5A, 250V slo-blow
Depth ...............................5cm (2")
Current Draw: ...................2.0A peak
Weight..............................21kg (46lbs.)
Width................................70cm (27 5/8”)
Input Power: .....................<180W
Transmitter
Outputs:............................2 ports (two antennas,
multiplexed)
Operating Frequency: ........58 or 60kHz (±200Hz)
Transmit Burst Duration.....1.6ms
Transmit Current: ..............16A peak
Burst Repetition Rate:
Based on 50Hz ac.............37.5Hz (Normal)
75Hz (Validation)
Based on 60Hz ac.............45Hz (Normal)
90Hz (Validation)
Receiver
Inputs: ..............................2 ports (two antennas,
multiplexed)
Center Frequency:.............58 or 60kHz
Receive Coil Resistance: ...1.6 ohms (±5%)
Alarm
Alarm Relay Output ...........DPDT contacts
Contact Switching Current .1.0A max.
Contact Switching Voltage .28V max.
Lamp/Audio Duration.........1–30 sec.
(1 sec. increments)
ADS PRO•MAX PEDESTALS
8000-2693-03, Rev. A
INSTALLATION GUIDE
Declarations
Regulatory Compliance (NonEuropean Power Pack)
Safety:............................ UL 1950
Can/CSA C22.2
No. 950
EMC:.............................. 47 CFR, Part 15
FCC COMPLIANCE: This equipment has been tested and
found to comply with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: 1) this device may
not cause harmful interference, and 2) this device must accept
any interference received, including interference that may
cause undesired operation.
EQUIPMENT MODIFICATION CAUTION: Equipment
changes or modifications not expressly approved by
Sensormatic Electronics Corporation, the party responsible for
FCC compliance, could void the user’s authority to operate
the equipment and could create a hazardous condition.
Other Declarations
WARRANTY DISCLAIMER: Sensormatic Electronics
Corporation makes no representation or warranty with respect
to the contents hereof and specifically disclaims any implied
warranties of merchantability or fitness for any particular
purpose. Further, Sensormatic Electronics Corporation
reserves the right to revise this publication and make changes
from time to time in the content hereof without obligation of
Sensormatic Electronics Corporation to notify any person of
such revision or changes.
LIMITED RIGHTS NOTICE: For units of the Department
of Defense, all documentation and manuals were developed at
private expense and no part of it was developed using
Government Funds. The restrictions governing the use and
disclosure of technical data marked with this legend are set
forth in the definition of “limited rights” in paragraph (a) (15)
of the clause of DFARS 252.227.7013. Unpublished - rights
reserved under the Copyright Laws of the United States.
10
INSTALLATION GUIDE
ADS PRO•MAX PEDESTALS
8000-2693-03, REV. A

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2000:06:16 15:59:22
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2000:06:16 15:59:24-04:00
Page Count                      : 10
EXIF Metadata provided by EXIF.tools
FCC ID Filing: BVCUMADSNE

Navigation menu