USA Alo Branch RC-30 Measurement Insturment Remote Control User Manual manual

USA Alinco Branch Measurement Insturment Remote Control manual

manual

Download: USA Alo Branch RC-30 Measurement Insturment Remote Control User Manual manual
Mirror Download [FCC.gov]USA Alo Branch RC-30 Measurement Insturment Remote Control User Manual manual
Document ID85132
Application IDQvpFM3xira2lLt/b+tzWIg==
Document Descriptionmanual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize1.44kB (17980 bits)
Date Submitted2000-02-03 00:00:00
Date Available2000-02-18 00:00:00
Creation Date1999-10-15 17:19:31
Producing SoftwareAcrobat PDFWriter 3.0 for Power Macintosh
Document Lastmod0000-00-00 00:00:00
Document Titlemanual
Document Creatoræ©¡
Document Author: æ©¡

Nomenclature
Transmission lamp
INSTRUCTION MANUAL
Power switch for RL-VH3
series
Battery warning lamp
for RC-30
Remote Controller for RL-VH3 Series
Mode switch control
(RL-VH3G does not have
Laser sensor mode.)
RC-30
Stop beam control
Manual focus control
( Only for RL-VH3A/G)
Foreword
Speed control
Thank you for purchasing the TOPCON Remote controller RC-30.
For the best performance of the instruments, please read these instructions carefully and keep them in a convenient location for future reference.
Alignment control
Slope mode /
X/Y axis selection
Handling Precautions
Vibration and Impact Protection
when transporting the instrument, provide protection to minimize risk of
severe vibration or impact.
X/Y axis lamp
Display for Safe Use
In order to encourage the safe use of products and prevent any danger
to the operator and others or damage to properties, important warnings
are put on the products and inserted in the instruction manuals.
We suggest that everyone understand the meaning of the following displays and icons before reading the “Safety Cautions” and text.
Display
Meaning
WARNING
Ignoring or disregard of this display may
lead to death or serious injury.
CAUTION
Ignoring or disregard of this display may
lead to personal injury or physical damage to the instrument.
1) Injury refers to hurt, burn, electric shock, etc.
2) Physical damage refers to extensive damage to buildings or
equipment and furniture.
Key Functions
Transmission lamp Sends operation to the instrument.
Battery warning
lamp for RC-30
Stop beam control
Speed control
Alignment control
X/Y axis lamp
Power switch for
RL-VH3 series
Safety Cautions
WARNING
• There is a risk of fire, electric shock or physical harm if you
attempt to disassemble or repair the instrument yourself.
This is only to be carried out by TOPCON or an authorized dealer,
only!
• Risk of fire or electric shock.
Do not use a wet battery or charger.
• May ignite explosively.
Never use an instrument near flammable gas, liquid matter, and
do not use in a coal mine.
• Battery can cause explosion or injury.
Do not dispose in fire or heat.
• The short circuit of a battery can cause a fire.
Do not short circuit battery when storing it.
CAUTION
Do not allow skin or clothing to come into contact with acid from
the batteries, if this does occur then wash off with copious
amounts of water and seek medical advice.
Mode switch control
Manual focus control
X/Y axis selection
If the channel is not equal to the channel set
at RL-VH3 side, the red lamp will light.
Battery warning for RC-30.
Replace the battery to new ones.
Sets Stop beam mode and moves the laser.
The rotation speed of the rotary head can be
changed.
Setting slope for horizontal rotation.
Alignment of the line for vertical rotation.
An axis selected turns on.
On/Off of the RL-VH3series by pressing this
key for more than three seconds.
(Sleep mode on/off)
Laser mode is switched alternately as follows.
Scan mode / Laser sensor mode / Laser
pointing mode.
If this key is pressed in other modes except
Scan, Laser sensor and Laser pointing
modes, the mode will change to scan mode.
If this key is pressed in manual focus mode,
manual focus will be cancelled.
Laser beam can be focused manually.
(Only for RL-VH3A/G)
Sets slope mode by pressing for more than
three seconds.
Select X or Y axis for manual grading.
To cancel the slope mode press this key for
more than three seconds.
How to Set Communication Channel
The same communication channel must
be assigned to both RC-30 and the RLVH3 series.
Remove the rubber cap and turn the
rotary switch to set a channel.
How Replace the RC-30
Batteries
1 Remove the battery cover from the
Specifications
Power source
Operating time
Operating temperature
Dimensions
Weight
Three “AA” cell batteries DC4.5V
Alkaline manganese dry batteries
Approx. 40 hours ( +20°C)
-20°C to +50°C (-4°F to +122°F)
157(L) x 64(W) x 34(H) mm
(6.2 (L) x2.5 (W) x 1.3(H) ) in
0.24kg (0.05 lbs)
Rotary switch
(with rubber
cap)
Battery cover
back of the RC-30 by pressing on the
cover and sliding it in the direction of
the arrow.
Remove the old batteries and replace
with new three “AA” cell alkaline batteries making sure each is
placed in the proper direction as indicated.
Replace the battery cover. You will hear a click when it snaps in
place.
Note
• Replace all 3 batteries with new ones.
• Do not mix old batteries and new ones.
(1a) RC-30 9910

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 1
Creator                         : .橡.
Create Date                     : 1999:10:15 17:19:31
Author                          : .橡.
Producer                        : Acrobat PDFWriter 3.0 for Power Macintosh
EXIF Metadata provided by EXIF.tools
FCC ID Filing: EUGRC-30

Navigation menu