UTC Fire and Security ATS1190-1192 Access Control Card Reader User Manual Copy of revision 3 ATS 1190 p65

UTC Fire & Security B.V. Access Control Card Reader Copy of revision 3 ATS 1190 p65

INSTALLATION GUIDE FOR ATS1190 AND 1192

Download: UTC Fire and Security ATS1190-1192 Access Control Card Reader User Manual Copy of revision 3 ATS 1190 p65
Mirror Download [FCC.gov]UTC Fire and Security ATS1190-1192 Access Control Card Reader User Manual Copy of revision 3 ATS 1190 p65
Document ID279780
Application IDvJfTriS6GXHxcrqXx8wZow==
Document DescriptionINSTALLATION GUIDE FOR ATS1190 AND 1192
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize67.49kB (843676 bits)
Date Submitted2002-10-29 00:00:00
Date Available2002-10-24 00:00:00
Creation Date2002-10-24 08:33:45
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2002-10-24 08:33:45
Document TitleCopy of revision 3 ATS 1190.p65
Document CreatorPageMaker 6.5
Document Author: 208037844

Smart Card Reader ATS1190/1192
Installation Guide
Introduction
The ATS1190/1192 Smart Card Readers are multifunction, all-purpose proximity card readers suitable for
all locations (including outdoors) requiring a short-range reader. The readers can be connected directly to
the Advisor Master RS485 BUS (see Figure 2). They are configurable through a menu system accessible
via the BUS or by configuration cards programmed through Titan and the Aritech Smart Card Programmer
(ATS1620).
The readers operate from 9 to 14 VDC. They have a quiescent current consumption of less than 25mA and
less than 80mA, when reading a card. The ATS1190 is supplied standard with a white removable cover,
which can be interchanged with one of four other colours available.
Figure 1: Smart Card Reader
Mounting
RAS
Addressing
A - Blue LED:
- Door open
- Disarmed
B - Comms:
- LED control
- Buzzer control
- Power
C - Red LED:
- Door open
- Armed
The readers can be mounted on any flat surface with two 3.0-3.5 mm diameter pan-head screws. A slightly
reduced range will be experienced when mounted on metal surfaces. If mounting in an outdoor
environment, ensure that the blue LED is at the top. The use of countersunk screws is not recommended.
Remove the ATS1190 cover to expose the mounting screw by gently prying the sides away from the main
body to release the retaining clips and gently pulling on the connection cord. Do not use excessive force or
the reader can be irreparably damaged. After mounting, gently press the cover over the main body until it
locks into place.
The address of the reader for BUS operations is set to the default address, RAS 16. You can change this by
using a configuration card or accessing its on-line menu system when it is connected to the RS485 BUS.
See the Programming Guide, Reader Address, for further details.
Figure 2: BUS Connection Block
+12 V
0V
D+
Tamper
Comms
- Red
- Black
- White
D–
- Green
Open collector - Violet
The reader is provided with a tamper facility. When connected to the BUS, tamper data is transmitted to
the Advisor Master with system data. An external Open Collector output (violet wire) can be configured as
a tamper control for both on-line and off-line operation.
Figure 3: Wiegand Connection Block
+12 V
- Red
0V
- Black
D0
- Green
D1
- White
L2
L1
BZ
Tamper
- Brown
- Yellow
- Blue
- Violet
Figure 4: Four-Door Controller Local Bus
+12 V
- Red
0V
- Black
D+
- White
D–
RTE
Tamper
- Green
- Yellow
- Violet
DWG#1190IG
Revision 4 10/02
Reader Wiring
Red:
Black:
Green:
0 Volts
D0 / Clock
White:
D1 / Data
Brown:
LED 1
Yellow:
LED 2
Blue:
Buzzer
Violet:
Open Collector
Technical
Current consumption
Specifications
FCC
Complicance
Positive 9 to 14 VDC supply
DC supply ground
RS485 Data - Wiegand Data 0
Absolute maximum, 12 V @ 10mA
RS485 Data + Wiegand Data 1
Absolute maximum, 12 V @ 10mA
Offline LED control configured to “Two Wire Control” will control
the red LED only.
Wire grounded: red LED on
Wire open: red LED off
Wire at +5 V to +12 V: Red LED off or, offline LED control configured to “One Wire Control” will control both the red and blue LEDs
Wire grounded: blue LED on
Wire open circuit: Both LEDs off
Wire at + 5 V to 12 V: red LED on
Absolute maximum, 14 V
Configurable to control the blue LED when offline
Wire grounded: blue LED on
Wire open: blue LED off
Wire at +5 V to +12 V: blue LED off
Request to exit input when online to Advisor Master
This input may be connected to a simple push button connected to
Ground with RTE Only selected on the option card or in Menu 10 (See
Programming Guide for more details).
Offline buzzer control.
Wire open or +5 V to +12 V: buzzer off
Wire grounded: buzzer sounding
Absolute maximum, 14 V
Configurable as: door relay, - tamper output, credit controlled
pulsed, timed or latched output
Note: This is a low current output and must not be used to directly
energize high current door openers.
Absolute maximum, 14 V @ 25mA
80mA max.
Input voltage
9VDC min., 14VDC max.
Operating temperature
-31° F to 150° F (-35° C to 66° C)
Humidity
95% non-condensing
This device complies with Part 15 of the FCC rules. Operation is subject to the following three conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired
operation.
3. Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
FCC ID: CGGATS1190-1192
ATS1190
1.
2.
12V
0V
D0
D1
L2
L1
BZ
Red
Black
Green
White
Brown
Yellow
Blue
Tamper
Violet
ATS4000
J10
+ 12 V
0V
D+
D-
Red
Black
White
Green
Open
Connec tor
Violet
D-
ATS1250
4K7
D+
J8 to J12
0V
+ 12
J13-J16
RAS
DD+
0V
+ 12
3.
4.
12V
0V
D0
D1
L2
L1
BZ
Red
Black
Green
White
Brown
Yellow
Blue
Tamper
Violet
ATS1250
4K7
+ 12V
0V
D+
DRTE
Tamper
Red
Black
White
Green
Yellow
Violet
ATS1250
J8 to J12
J13-J16
D-
J8 to J12
J22
D+
0V
+ 12
Request to Exit (RTE)
ATS1192
1.
2.
ATS4000
J10
+ 12 V
0V
D+
D-
Open
Connec tor
Red
Black
White
Green
Violet
DD+
0V
+ 12
RAS
DD+
0V
+ 12
3.
4.
12V
0V
D0
D1
L2
L1
BZ
Red
Black
Green
White
Brown
Yellow
Blue
Tamper
Violet
ATS1250
4K7
+ 12V
0V
D+
DRTE
Tamper
Red
Black
White
Green
Yellow
Violet
ATS1250
J8 to J12
J13-J16
D-
J8 to J12
J22
D+
0V
+ 12
Request to Exit (RTE)

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2002:10:24 08:33:45-07:00
Modify Date                     : 2002:10:24 08:33:45-07:00
Page Count                      : 4
Creation Date                   : 2002:10:24 15:33:45Z
Mod Date                        : 2002:10:24 15:33:45Z
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : 208037844
Metadata Date                   : 2002:10:24 15:33:45Z
Creator                         : 208037844
Title                           : Copy of revision 3 ATS 1190.p65
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CGGATS1190-1192

Navigation menu