UTStarcom Korea Technologies UTS-EA7H75B Wireless Local Loop Fixed Terminal User Manual Cover
UTStarcom Korea Technologies Ltd. Wireless Local Loop Fixed Terminal Cover
Contents
Manual 1
Wireless Local Loop RPC/RP Installation & Configuration Manual WLL-RPC/RP-IN/UM-1.0 June 19, 2000 ii RPC/RP Manual Compiled by (Joseph) Guangping Zhang Copyright 2000 UTStarcom Inc. All Rights Reserved. This manual has been prepared for UTStarcom customers, UTStarcom personnel, and licensees. The information contained herein is the property of UTStarcom Inc. and shall be neither reproduced nor utilized in any form or by any means, electronically or mechanically, in whole or in part, without prior written approval from UTStarcom Inc. WLL-RPC/RP-IN/UM-1.0 19June2000 RPC/RP Manual iii Important Safety Instructions Safety Information: Installer and User WARNING The device is to be installed and operated at a “fixed location”. The term "fixed location" means that the device is physically secured at one location and is not able to be easily moved to another location. It must be located - (for indoor RPs) up on or near the ceiling away from users or bystanders – (for outdoor RPs) on the roof top site, pole, building, or traffic light away from users or bystanders. It must be mounted in a manner to ensure that a minimum separation distance of 20cm is normally maintained between all users, bystanders and the antenna (including any radiating structure). The installer may be required to perform an MPE evaluation and an Environmental Assessment (EA) of the location at the time of licensing per CFR 47 Part 1.1307. Fixed mounted antennae that are co-located with other antennae must satisfy the co-location requirements of Part 1.1307. Limits: The limit for general population/uncontrolled environment exposures is 1 mW / cm 2 for the band 1500-100,000 MHz. MPE evaluation: The following calculations are provided for the more restrictive limit: uncontrolled environment/general population. The calculated minimum safe distance, Radii(cm), is approximately 10 times lower than the minimum required installation distance of 20 cm per Part 2.1091. 19June2000 WLL-RPC/RP-IN/UM-1.0 iv RPC/RP Manual Therefore, the transmitter model numbers EA7H74B and EA7H75B complies with the MPE requirements by providing a safe separation distance between the antenna (including any radiating structure) and any persons. The calculations were performed using formulas found in OET Bulletin 65 Edition 97-01(1997). Transmitter Specifications: Antenna Type Gain (dBi) Output power EIRP (dBm) Output Power (dBm) Base stations M/N 2.4 2.4 21.4 12.4 26 19 dBm (Peak) 10 dBm (avg) 19 dBm(Peak) EA7H74B EA7H74B EA1H75B Minimum Installation Distance (cm) 20 20 20 17 10 dBm (avg) EA1H75B 20 Built-in OmniDirectional MPE Radii (m) For general population/uncontrolled environment Power P(W) Max. Peak Antenna G numeric Radii(cm) 0.08 0.08 1.7 5.0 1.5 2.5 Base stations M/N EA7H74B EA1H75B General Safety Instructions: • The sign on the top right corner is intended to alert the user the presence of important operation and maintenance (service) instructions in the literature accompanying the product. Also notice warnings such as “WARNING!” or “CAUTION.” • When installing, operating, or maintaining the system, please follow the basic safety procedures in order to reduce the risk of fire, electric shock, and injury to persons, as listed below: • Read and understand all instructions. • Follow all warnings and instructions marked on this product. • For information on proper mounting instructions, consult the Installation Manual provided with this product. • Install only equipment identified in the Installation Manual provided with this product. Use of other equipment may result in improper connection of circuitry leading to fire or injury to persons. WLL-RPC/RP-IN/UM-1.0 19June2000 RPC/RP Manual 19June2000 • The telecommunication interfaces should not leave the building unless connected to telecommunication devices providing primary and secondary protection, as applicable. • This product should only be operated from the type of power source indicated on the marking label. • This equipment must be provided with a readily accessible disconnect device as part of the building installation. • Installation must include an independent frame ground drop to building ground. Refer to installation instructions. • Do not use this product near water, for example in a wet basement. • Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious damage to the product. • Use caution when installing or modifying telecommunications lines. • Never install telecommunications wiring during a lightning storm. • Never install telecommunications in wet locations. • Never touch uninsulated telecommunications wires or terminals unless the telecommunications line has been disconnected at the network interface. • Never touch uninsulated telecommunications wires or terminals carrying direct current or ringing current or leave this wiring exposed. Protect and tape such wiring and terminals to avoid risk of fire, electric shock, and injury to service personnel. • Never push objects of any kind into this product through slots as they may touch dangerous voltage points or short-out parts that could result in a risk of fire or electrical shock. Never spill liquids of any kind on this product. • Slots and openings in the unit are provided for ventilation, to protect it from overheating. These openings must not be blocked or covered. This product should not be placed in a built-in installation unless proper ventilation is provided. • To reduce the risk of an electrical shock, do not disassemble this product. Service should be performed by trained personnel only. Opening or removing covers and/or circuit boards may expose you to dangerous voltages or other risks. Incorrect re-assembly can cause electrical shock when the unit is subsequently used. WLL-RPC/RP-IN/UM-1.0 vi RPC/RP Manual • This equipment is intended for installation in restricted access locations where access is controlled or where access can only be gained by service personnel with a key or tool. Access to this equipment is restricted to qualified service personnel. Save These Instructions! WLL-RPC/RP-IN/UM-1.0 19June2000 RPC/RP Manual vii Table of Contents INTRODUCTION ...................................................................................................................................................1-1 1.1 P URPOSE ...................................................................................................................................................................1-1 1.2 ORGANIZATION ........................................................................................................................................................1-1 1.3 DOCUMENTATION CONVENTIONS ...........................................................................................................................1-2 2 RPC INSTALLATION ................................................................................................................................................2-1 2.1 GENERAL D ESCRIPTION ...........................................................................................................................................2-1 2.1.1 Main RPC Features .........................................................................................................................................2-2 2.1.2 RPC Module Descriptions ...............................................................................................................................2-3 2.1.2.1 Enhanced Control Module ..............................................................................................................................2-4 2.1.2.2 E1 Interface Module .......................................................................................................................................2-5 2.1.2.3 Radio Port Interface Module ...........................................................................................................................2-7 2.1.2.4 Application Software Loading Module ............................................................................................................2-9 2.1.2.5 ADPCM Highway........................................................................................................................................2-10 2.2 SYSTEM CONSTRUCT ION ...................................................................................................................................... 2-10 2.3 INSTALLATION....................................................................................................................................................... 2-12 2.3.1 Before Beginning........................................................................................................................................... 2-12 2.3.2 RPC Site Selection......................................................................................................................................... 2-12 2.3.3 Tools Required .............................................................................................................................................. 2-13 2.3.4 Installation Instructions................................................................................................................................ 2-13 3 RP INSTALLATION ...................................................................................................................................................3-1 3.1 GENERAL D ESCRIPTION ...........................................................................................................................................3-1 3.1.1 Traffic Handling...............................................................................................................................................3-3 3.1.2 Cell Overlap .....................................................................................................................................................3-5 3.1.3 Air Interface Handling.....................................................................................................................................3-6 3.2 SYSTEM CONSTRUCTION .........................................................................................................................................3-8 3.3 INDOOR RP I NSTALLATION INSTRUCTIONS ......................................................................................................... 3-10 3.3.1 Before Beginning........................................................................................................................................... 3-10 3.3.2 Site Selection ................................................................................................................................................. 3-11 3.3.3 Indoor RP Installation .................................................................................................................................. 3-11 3.4 OUTDOOR RP I NSTALLATION INSTRUCTIONS ...................................................................................................... 3-13 3.4.1 Before Beginning........................................................................................................................................... 3-14 3.4.2 Outdoor RP Installation................................................................................................................................ 3-14 4 RPC/RP CONFIGURATION .....................................................................................................................................4-1 4.1 INITIALIZE AN RPC NODE .......................................................................................................................................4-1 4.1.1 Background Map..............................................................................................................................................4-5 4.1.2 Add RPC Icons on the Map .............................................................................................................................4-7 4.1.3 Add RP Icons....................................................................................................................................................4-9 4.2 RPC CONFIGURATION .......................................................................................................................................... 4-11 4.2.1 Set Time.......................................................................................................................................................... 4-12 4.2.2 RPC Change .................................................................................................................................................. 4-13 4.2.3 Unit Control................................................................................................................................................... 4-13 4.2.3.1 Blockade/Unblockade...................................................................................................................................4-14 4.2.3.2 TimeSlot Layout ..........................................................................................................................................4-16 4.2.3.3 Maintenance.................................................................................................................................................4-17 4.2.3.4 Change Master RP........................................................................................................................................4-18 4.2.3.5 RPC Synchronization ...................................................................................................................................4-18 4.2.3.6 Online Trace ................................................................................................................................................4-20 4.2.4 Function Status.............................................................................................................................................. 4-21 19June2000 WLL-RPC/RP-IN/UM-1.0 viii RPC/RP Manual 4.2.4.1 RPC Status ...................................................................................................................................................4-22 4.2.4.2 RP Status .....................................................................................................................................................4-23 4.2.4.3 RP-I/F Board Status .....................................................................................................................................4-28 4.2.4.4 E1 Signal Status ...........................................................................................................................................4-29 4.2.4.5 E1 Interface Status .......................................................................................................................................4-30 4.2.4.6 Air Channel Status .......................................................................................................................................4-31 4.2.4.7 Time Slot Status ...........................................................................................................................................4-32 4.2.5 Self Messages................................................................................................................................................. 4-33 4.2.6 Reset RPC...................................................................................................................................................... 4-34 4.2.7 Antenna Information..................................................................................................................................... 4-36 4.2.8 RPC Connection............................................................................................................................................ 4-37 4.2.9 Version Window............................................................................................................................................ 4-37 4.3 MANAGE RPC DATA ............................................................................................................................................ 4-38 4.3.1 Program Load ............................................................................................................................................... 4-38 4.3.2 Program Switch ............................................................................................................................................. 4-40 4.3.3 Data Load ...................................................................................................................................................... 4-41 4.3.4 Data Switch.................................................................................................................................................... 4-42 4.3.5 Read Data ...................................................................................................................................................... 4-43 4.3.6 Write Data ..................................................................................................................................................... 4-44 4.3.7 Copy Data...................................................................................................................................................... 4-46 4.3.8 Edit Data........................................................................................................................................................ 4-46 4.3.8.1 Service Data 1: RP Installation .....................................................................................................................4-47 4.3.8.2 Service Data 2: Group Control Configuration................................................................................................4-48 4.3.8.3 Service Data 3: System Parameters ...............................................................................................................4-50 4.3.9 Change Data (RP Installation)..................................................................................................................... 4-58 4.3.10 Change Data (E1-IF Board Installation).................................................................................................. 4-60 4.3.11 Change Data (Data Value)......................................................................................................................... 4-61 4.4 MANAGE RPC ALARMS........................................................................................................................................ 4-62 4.4.1 Warning Status.............................................................................................................................................. 4-62 4.4.2 Alarm History ................................................................................................................................................ 4-63 4.5 RESET RPC............................................................................................................................................................ 4-64 4.6 RPC STATISTICS ................................................................................................................................................... 4-67 4.6.1 RPC Traffic Report ....................................................................................................................................... 4-67 4.6.2 RPC Outstanding Alarms ............................................................................................................................. 4-69 4.6.3 RP Status Report ........................................................................................................................................... 4-70 A SPECIFICATIONS ...................................................................................................................................................A-1 A.1 RPC SPECIFICATIONS ............................................................................................................................................A-1 A.1.1 Champ Connector Pin Assignments.............................................................................................................. A-2 A.2 RP SPECIFICATIONS ...............................................................................................................................................A-4 A.2.1 Radio Features................................................................................................................................................ A-4 A.2.2 Outdoor Type RP ............................................................................................................................................ A-4 A.2.2.1 Antenna .......................................................................................................................................................A-5 A.2.3 Indoor Type RP............................................................................................................................................... A-5 B GLOSSARY.................................................................................................................................................................B-1 C EDITOR’S NOTE ......................................................................................................................................................C-1 C.1 C.2 C.3 NOTICE TO CUSTOMERS ...................................................................................................................................C-1 HOW TO COMMENT ON THIS D OCUMENT ........................................................................................................C-3 FEEDBACK FORM ..............................................................................................................................................C-5 WLL-RPC/RP-IN/UM-1.0 19June2000 RPC/RP Manual 19June2000 ix WLL-RPC/RP-IN/UM-1.0 x WLL-RPC/RP-IN/UM-1.0 RPC/RP Manual 19June2000 Introduction 1 Introduction 1.1 Purpose This manual describes the installation and configuration procedures for the Radio Port Controller (RPC) and Radio Port (RP). It is intended for the following customer personnel who participate in the engineering, installation, operations, and maintenance of the system. • • • • Equipment Engineers and outside plant engineers Installation, Operation, and Maintenance Personnel System Administrators Training Personnel 1.2 Organization Listed below is the brief description of each chapter in this manual: Introduction - Describes the contents of this manual and the conventions used. RPC Installation - Details the steps necessary to install the Radio Port Controller. RP Installation - Represents the procedures to install the Radio Port. RPC/RP Configuration - Explains the configuration process for both the RPC and the RP. Appendix A: Specifications – Describes the RPC/RP specifications and Champ connector pin assignments. Appendix B: Glossary – Lists the meaning of the acronyms used in this manual. Appendix C: Editor’s Note – Provides the notice to the customers, customer service office addresses, and feedback form. 19June2000 WLL-RPC/RP-IN/UM-1.0 1-2 Introduction RPC/RP Manual 1.3 Documentation Conventions Certain conventions are used in this document to denote types of information, such as commands, screen titles, options, and so on. The table below defines these conventions. Style Italics Bold Bold andUnderlined Bold and Italics followed by italic text Initial Capital LettersUsed For: Cited titles of books, chapters, and sections in the literature Window and dialog box names, icon names, and field names Menu names Menu options, command, and button names Notes, cautions, and warnings Names of functions, window tabs, and directory and file names Variable sytem output Example Performance Management Netman Database Window Configuration Configure DLC NOTE: This feature does not apply to RPC nodes. Double click the E1 Port Index field. The status displayed is COMM Table 1-1: Documentation Conventions WLL-RPC/RP-IN/UM-1.0 19June2000 RPC/RP Manual 19June2000 Introduction 1-3 WLL-RPC/RP-IN/UM-1.0 RPC Installation 2 RPC Installation 2.1 General Description The Radio Port Controller (RPC) functions as the controller and power distributor for the Radio Ports (RPs). It is also the concentrator of the speech paths and the protocol converter for the PHS protocol and the Q.931 protocol. It has Dual Tone Multi Frequency (DTMF) senders for dialing to the Local Exchange (LE) through the Central Office Terminal (COT). In addition, the RPC synchronizes the associated RPs by extracting the synchronous clock from the E1 line connected to the COT and distributing it to all of the associated RPs. RPCs can be co-located with a COT or located remotely and communicate with the COT using E1 transmission over: • • • High Density Subscriber Loop (HDSL) Fiber Optic Transmission (FOT) Digital microwave radio Figure 2-1 presents an overview of the RPC and RPs in the WLL system. 19June2000 WLL-RPC/RP-IN/UM-1.0 2-2 RPC Installation RPC/RP Manual Figure 2-1: RPC in the WLL System 2.1.1 Main RPC Features An RPC consists mainly of four types of function modules: • • • • One ECNT (Enhanced Control) module Up to four E1IF (E1 Interface) modules Up to eight RPIF (RP Interface) modules One APL (Application Software Loading) module - Optional Figure 2-2 displays the four types of the function modules in the RPC. WLL-RPC/RP-IN/UM-1.0 19June2000 RPC/RP Manual RPC Installation 2-3 Figure 2-2: Function Modules inside the RPC Each RPC can handle traffic loads of up to 120 simultaneous telephone calls. Four E1 trunks connect to the COT side and support 30 subscriber channels each. In normal traffic conditions, a single RPC can service approximately 1000 subscribers. The RPC is monitored and controlled from the network management system connected to the COT. With this setup the program data, the operation data, and the system parameters can be changed and the alarm information and traffic data can be gathered easily. 2.1.2 RPC Module Descriptions The following sections describe the RPC component modules, including the physical configuration, Light Emitting Diodes (LEDs), and switch operations. 19June2000 WLL-RPC/RP-IN/UM-1.0 2-4 RPC Installation RPC/RP Manual 2.1.2.1 Enhanced Control Module The ECNT module provides the Operation, Administration and Maintenance (OA&M) support for the RPC. In addition, it provides the time slot cross connect switch for communications between the E1IFs and the RPIFs. Figure 2-3 represents the ECNT functions. Figure 2-3: ECNT Block Diagram The ECNT module performs the clock synchronization by generating a synchronized clock from the extracted clock signal from the E1 line on the E1 interface card and delivers it to the RP lines on the RP interface cards. The RPC uses a control bus via the ADPCM highway on the mother board to synchronize the system. The Control Bus is an 8-bit mixed bus address with data and First-in First-out (FIFO) type bus. The main CPU on the ECNT card, the local CPUs on E1 Interface cards and the RP-interface cards are all connected by this bus. The main CPU on the ECNT card controls the bus. WLL-RPC/RP-IN/UM-1.0 19June2000 RPC/RP Manual RPC Installation 2-5 Figure 2-4 shows the module’s physical configuration and describes the function of the LEDs and the reset switch. ALM : Red =fault detected on this module RUN : Green=normal operations SYNC : Green=E1 interface circuit established Layers 1 and 3 LEDs 0 through 7 : Red=Frame Rotary Switch (U) : Setting=0 Rotary Switch (L) : Setting=2 RMT or PC Connector System Reset Switch : =Normal operations =Reset system Alarm Reset Switch : =Normal operations =Reset alarms Figure 2-4: ECNT Module Layout 2.1.2.2 E1 Interface Module The RPC connects to the COT through a 2.048 Mbps E1 Interface that carries all the control and voice channels, that is, PCM encoded voice or voice band data, between the COT and the RPC. The E1 Interface (E1IF) module communicates externally with the COT through 1 G.703 E1 interface and uses Q.931 non-facility associated signaling protocol. Transmission between the RPC and RP is based on a proprietary, echo-canceled transmission standard, which is similar to the recognized G.961 ISDN standard. The E1IF provides the speech coding conversion between A-law PCM from the COT and Adaptive Differential Pulse Code Modulation (ADPCM), which is ITU- 19June2000 WLL-RPC/RP-IN/UM-1.0 2-6 RPC Installation RPC/RP Manual Rec.726 compliant, from the RP. It supports 32 kbps channel signaling for encoded voice and voice band data calls. In addition, the E1IF communicates internally with the Radio Port Interface (RPIF) module for interfacing RPs through the backplane busses and the switch in the ECNT module. The E1IF module is an E1 module (E1M) that provides 4 E1 connections to the E1 network. The E1 module has the following functions: • • • • • • Originates/terminates 4 G.703/G.704 2.048 Mbps E1 interface Provides 75 ohm unbalanced interface Provides LEDs for module and port status and alarms Performs CRC-4 on the E1 line according to G.706 Monitors performance of each E1 line Detects errors and alarms on the E1 lines. Figure 2-5 depicts the processing of the E1IF module ADPCM Highway Highway Exchanger Reference Clock Internal Bus A-law PCM Highway A-law PCM Highway ADPCM CODEC Loudness Controller E1 to COT E1 IF LSI LIF DTMF Sender Address Bus Bus Controller CPU Data Bus DPRAM (16 bit) +5 V RAM ROM Figure 2-5: E1 Interface (E1IF) Module Block Diagram Figure 2-6 shows the module’s physical configuration and describes the function of the LEDs and the reset switch. WLL-RPC/RP-IN/UM-1.0 19June2000 RPC/RP Manual RPC Installation 2-7 ALM : Red =fault detected on this module RUN : Green=normal operations CHM : Green=E1 interface circuit has established Layers 1 and 3 FSYC : Red=Frame out of synchronization is dectected LOS : Red=loss of signal is dectected AIS : Red=Alarm indication signal is detected RAI : Red=RAI signal is detected RST Switch : =Resets the entire interface module = Normal operations Figure 2-6: E1IF Module Layout 2.1.2.3 Radio Port Interface Module Each RPC controls and feeds a maximum of 32 RPs. The RPC connects to the RPs through a 2-wire proprietary interface. Line power feeding from the RPC provides a power source of 116V DC to the RPs. The RPC controls the RPs via 8 RPIF modules. Each RPIF module provides an ISDN Basic Rate interface to 4 RPs. The RP is extended from the RPC to a maximum distance of 5.0km using a pair of φ0.5 wires and approximately 3.5 km using a pair of φ0.4 wires. The Radio Port Interface (RPIF) module communicates externally with four RPs through ISDN Basic Rate Interfaces (BRI). In addition, it communicates 19June2000 WLL-RPC/RP-IN/UM-1.0 2-8 RPC Installation RPC/RP Manual internally with the E1IF through the backplane busses and the switch in the ECNT module. Refer to Figure 2-7 for a block diagram of the RPIF module’s processing. Layer 1 LSI RPIF RPIF Layer 1 LSI RPIF Layer 1 LSI RPIF Layer 1 LSI -116V ADPCM Highway Time slot Assignment Controller PCM Clock/ Frame ADPCM Clock signal Generator HDLC Controller Internal BUS Address Bus CPU (16 bit) +5V ADPCM Highway DPRAM Data Bus ROM Bus Controller RAM Figure 2-7: RPIF Module Block Diagram Figure 2-8 shows the module’s physical configuration and describes the function of the LEDs and the reset switch. WLL-RPC/RP-IN/UM-1.0 19June2000 RPC/RP Manual RPC Installation 2-9 ALM : Red =fault detected on this module RUN : Green=normal operations SUS: Green=one or more Rps operational Not Lit=operations suspended on all connected RPs Distance S w i Short RP1 through RP4 : Green=normal operations Red=RP not connected, is faulty or is blocked RST Switch : =Resets the entire interface module = Normal operations Figure 2-8: RPIF Module Layout 2.1.2.4 Application Software Loading Module The Application Software Loading (APL) Module facilitates the downloading of software in the event there is a problem in loading software. It permits the upgrading of the ECNT module firmware. In addition, any software upgrades can be downloaded remotely from a PC to an RPC. The APL module is installed only when the software or firmware needs to be upgraded or downloaded. It is not intended to remain in the system during the normal operations. Figure 2-9 demonstrates the module’s physical configuration: 19June2000 WLL-RPC/RP-IN/UM-1.0 2-10 RPC Installation RPC/RP Manual Figure 2-9: Application Module Layout 2.1.2.5 ADPCM Highway The ADPCM (Adaptive Differential Pulse Code Modulation) highway is the synchronous time multiplex digital voice/data path, and consists of up-stream and down-stream for Time Switch on the ECNT card. Time Switch and the digital voice and data paths on the E1IF cards and the RPIF cards are connected by the ADPCM highway. There are 8 ADPCM highways in an RPC. Half of them are assigned for E1IF cards, and the rest are assigned for RPIF cards. The bit rate of an ADPCM highway is 2048 kbps, and the frame repetition rate is 8 kHz. 2.2 System Construction An RPC has two types of installation scenarios: • • WLL-RPC/RP-IN/UM-1.0 Rack mount Stand-alone 19June2000 RPC/RP Manual RPC Installation 2-11 Figure 2-10 shows the physical configuration of the rack mount type RPC. Figure 2-10: Layout of Rack Mount Type RPC The RPC is 532.6mm high, 482.6mm wide, and 265mm deep. 19June2000 WLL-RPC/RP-IN/UM-1.0 2-12 RPC Installation RPC/RP Manual 2.3 Installation This section provides the instructions for installing an RPC. The flow chart in Figure 2-11 depicts the steps involved in the installation. Figure 2-11: RPC Installation Flow Chart 2.3.1 Before Beginning To ensure that the RPC installation goes smoothly, it is necessary to do adequate planning prior to the installation, including: • • • Location of the RPC Tools required Number of people needed to complete an installation. 2.3.2 RPC Site Selection The RPC needs an environment that is relatively dust and moisture free. Make sure the location meets the following requirements: WLL-RPC/RP-IN/UM-1.0 19June2000 RPC/RP Manual RPC Installation • • • 2-13 Not in direct sunlight Free from extremes of heat, cold, and moisture 0° to 40° C ambient temperature 2.3.3 Tools Required Be sure to have the following necessary tools: • • • Screwdrivers Soldering iron and solder Tie bands for cabling 2.3.4 Installation Instructions Follow the steps below to install the RPC: 1. Carefully unpack the RPC and the accessories and make sure that they are in good condition. Accessories include 2 connectors for the RP connection cables. Refer to Figure 2-12 for unpacking. 19June2000 WLL-RPC/RP-IN/UM-1.0 2-14 RPC Installation RPC/RP Manual Figure 2-12: Unpacking the RPC and Accessories 2. Before installing the RPC in the rack, make sure to remove the card cover and the power source cover. CAUTION: Do not take a photo with a flash once the card cover has been removed. RPC may not operate. 3. Loosen the thumbscrews. Tilt open the cover and slide it out as shown in Figure 2-13. WLL-RPC/RP-IN/UM-1.0 19June2000 RPC/RP Manual RPC Installation 2-15 CAUTION: The card cover cannot hold itself when opened. Be sure to detach it from the cabinet. Figure 2-13: Removal of the Card Cover 4. Remove the 5 M3 screws in the power source cover and remove it, as illustrated in Figure 2-14. 19June2000 WLL-RPC/RP-IN/UM-1.0 2-16 RPC Installation RPC/RP Manual Figure 2-14: Removal of the Power Source Cover CAUTION: When inserting and removing each component, make sure to follow the proper electro-static discharge (ESD) procedures. 5. Connect and wire the power source and FG cables, as shown in the figure below. WLL-RPC/RP-IN/UM-1.0 19June2000 RPC/RP Manual RPC Installation 2-17 Figure 2-15: Power and FG Cable Connectors 6. Insert the RPC in the rack and fasten to the rack with 8 screws as indicated in Figure 2-16. 19June2000 CAUTION: Make sure the RPC is firmly mounted in the rack. Serious injury could occur if the RPC fell out of the rack. WLL-RPC/RP-IN/UM-1.0 2-18 RPC Installation RPC/RP Manual Figure 2-16: Mounting the RPC in the Rack 7. After installing the RPC in the rack, affix the wiring as indication in Figure 2-17. Redirect the support according to the direction of the wiring, as shown in Figure 2-17. WLL-RPC/RP-IN/UM-1.0 19June2000 RPC/RP Manual RPC Installation 2-19 Figure 2-17: Wiring – Back of RPC 8. Connect the coaxial cable with an SMB coaxial cable plug having an impedance of 75 ohms into the E1IF connectors on the back of the RPC, as shown in Figure 2-17 9. Connect the cable with a Champ plug to the RPIF connector on the back of the RPC. Refer to Figure 2-17. Table 2-1 provides the maximum cable lengths between the RPC and the RP for 2 different wire gauges. Refer to Appendix A for the description of the 2 Champ RPIF connector pin assignments. 19June2000 WLL-RPC/RP-IN/UM-1.0 2-20 RPC Installation Wire Guage φ0.4 m φ0.5 m RPC/RP Manual Maximum Cable Length 3.5Km 5.0Km Table 2-1: Maximum RP Cable Length NOTE: Be sure to use a twisted pair cable or a 2 pair twisted cable. Avoid any 2 pair twisted cable splits before connecting cables. 10. When the RP and E1 cables are connected, attach the cabling to the supports with tie bands. Refer to Figure 2-18. NOTE: Tie Bands are to be prepared on-site. Figure 2-18: Cabling Example WLL-RPC/RP-IN/UM-1.0 19June2000 RPC/RP Manual RPC Installation 2-21 11. Install the modules in the RPC slots according to the labels on the cabinet. Refer to Figure 2-19 for the slot assignment. NOTE: The APL module is installed only when the software upgrades are unsuccessful without it. It is not intended to remain in the system during normal operations. Figure 2-19: RPC Slot Assignment 12. Make sure that the rotary switches on the ECNT module are correctly set before applying power. The correct switch settings are shown in Table 2-2. 19June2000 WLL-RPC/RP-IN/UM-1.0 2-22 RPC Installation Switch Name Rotary Switch (U):S4 Rotary Switch (L):S5 RPC/RP Manual Setting Table 2-2: Rotary Switch Settings 13. Slide the card into the RPC shelf using the upper and lower slot guides. When properly seated, the lower edge of the card is recessed from the outer edge of the lower slot guide. And the upper edge of the card is flush with the outer edge of the upper card guide. Refer to Figure 2-20. WLL-RPC/RP-IN/UM-1.0 19June2000
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Modify Date : 2003:01:17 15:43:33-07:00 Create Date : 2003:01:17 14:00:11-07:00 Title : Cover.PDF Author : mfleming Creator : Microsoft Word Producer : Acrobat PDFWriter 4.05 for Windows Page Count : 35EXIF Metadata provided by EXIF.tools