UTStarcom Korea Technologies UTS-EA7T56B Wireless Local Loop Phone System User Manual 2 General Description
UTStarcom Korea Technologies Ltd. Wireless Local Loop Phone System 2 General Description
Contents
- 1. Install Manual
- 2. Users Manual
Install Manual
200mW Radio Port Installation Manual WLL-200mW-RP-IN-1.0 July 25, 2000 2 200mW RP Installation RPC/RP Manual Compiled by (Joseph) Guangping Zhang Copyright 2000 UTStarcom Inc. All Rights Reserved. This manual has been prepared for UTStarcom customers, UTStarcom personnel, and licensees. The information contained herein is the property of UTStarcom Inc. and shall be neither reproduced nor utilized in any form or by any means, electronically or mechanically, in whole or in part, without prior written approval from UTStarcom Inc. WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation Important Safety Instructions • The sign on the top right corner is intended to alert the user the presence of important operation and maintenance (service) instructions in the literature accompanying the product. Also notice warnings such as “WARNING!” or “CAUTION.” • When installing, operating, or maintaining the system, please follow the basic safety procedures in order to reduce the risk of fire, electric shock, and injury to persons, as listed below: • Read and understand all instructions. • Follow all warnings and instructions marked on this product. • For information on proper mounting instructions, consult the Installation Manual provided with this product. • Install only equipment identified in the Installation Manual provided with this product. Use of other equipment may result in improper connection of circuitry leading to fire or injury to persons. • The telecommunication interfaces should not leave the building unless connected to telecommunication devices providing primary and secondary protection, as applicable. • This product should only be operated from the type of power source indicated on the marking label. • This equipment must be provided with a readily accessible disconnect device as part of the building installation. • Installation must include an independent frame ground drop to building ground. Refer to installation instructions. • Do not use this product near water, for example in a wet basement. • Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious damage to the product. 25July2000 WLL-200mW-RP-IN-1.0 4 200mW RP Installation RPC/RP Manual • Use caution when installing or modifying telecommunications lines. • Never install telecommunications wiring during a lightning storm. • Never install telecommunications in wet locations. • Never touch uninsulated telecommunications wires or terminals unless the telecommunications line has been disconnected at the network interface. • Never touch uninsulated telecommunications wires or terminals carrying direct current or ringing current or leave this wiring exposed. Protect and tape such wiring and terminals to avoid risk of fire, electric shock, and injury to service personnel. • Never push objects of any kind into this product through slots as they may touch dangerous voltage points or short-out parts that could result in a risk of fire or electrical shock. Never spill liquids of any kind on this product. • Slots and openings in the unit are provided for ventilation, to protect it from overheating. These openings must not be blocked or covered. This product should not be placed in a built-in installation unless proper ventilation is provided. • To reduce the risk of an electrical shock, do not disassemble this product. Service should be performed by trained personnel only. Opening or removing covers and/or circuit boards may expose you to dangerous voltages or other risks. Incorrect re-assembly can cause electrical shock when the unit is subsequently used. • This equipment is intended for installation in restricted access locations where access is controlled or where access can only be gained by service personnel with a key or tool. Access to this equipment is restricted to qualified service personnel. Save These Instructions! WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation Table of Contents 1 Equipment Description ...............................................................................................................................................6 1.1 200mW RP ..........................................................................................................................................................6 1.1.1 List of Component Parts ...............................................................................................................................6 1.1.2 Appearance of 200mW RP and Component Parts........................................................................................8 1.1.2.1 200mW RP ............................................................................................................................................8 1.1.2.2 Mounting Plate .................................................................................................................................10 1.1.2.3 M4 Screw.............................................................................................................................................10 1.1.2.4 M6 Screw.............................................................................................................................................11 1.1.2.5 M6 Spring Washer...............................................................................................................................11 1.1.2.6 M6 Plane Washer.................................................................................................................................11 1.1.2.7 M6 Nut.................................................................................................................................................12 1.2 Joint Box............................................................................................................................................................12 1.2.1 List of Component Parts .............................................................................................................................12 1.2.2 Joint Box Unpacking ..................................................................................................................................12 1.2.3 Joint Box and Component Parts .................................................................................................................14 1.2.3.1 Joint Box..............................................................................................................................................14 1.2.3.2 Hexagon Socket Head Screw...............................................................................................................15 1.2.3.3 M6 Spring Washer...............................................................................................................................15 1.2.3.4 M6 Plane Washer.................................................................................................................................15 1.2.3.5 M6 Nut.................................................................................................................................................15 2 Wiring Cables to the Joint Box.................................................................................................................................15 2.1 Opening the Joint Box Cover ............................................................................................................................15 2.2 Making Connections..........................................................................................................................................17 2.3 Names of the Connection Joints ........................................................................................................................18 2.4 Connecting the AC Power Cables and FG Cables.............................................................................................19 2.5 Connecting the Line Cables...............................................................................................................................21 2.6 Fixing the AC Power Cables and FG Cables.....................................................................................................22 2.7 Fixing the Line Cables.......................................................................................................................................24 2.8 Waterproof Treatment of the Line Cables .........................................................................................................25 2.9 Closing the Joint Box Cover..............................................................................................................................27 3 Opening/Closing Cover of 200mW RP ....................................................................................................................28 3.1 Opening the Top Cover .....................................................................................................................................28 3.2 Fixing the 200mW RP to the Mounting Plate....................................................................................................30 3.3 Closing the Top Cover................................................................................................................................... 3-31 Appendix ................................................................................................................................................................. 3-33 A.1 200mW RP Cable Length ............................................................................................................................. 3-33 A.2 The Exchange of the Fuse............................................................................................................................. 3-34 A.3 Electric Connection ...................................................................................................................................... 3-35 A.4 Example of Layout ....................................................................................................................................... 3-36 A.5 Suitable Size of the Local Cable................................................................................................................... 3-37 A.6 Tape Wrapping ............................................................................................................................................. 3-38 A.7 Water Proof of Antenna Cable...................................................................................................................... 3-39 A.8 Grounding Protective Earthing Cable........................................................................................................... 3-40 A.9 Installation Image ......................................................................................................................................... 3-42 25July2000 WLL-200mW-RP-IN-1.0 6 200mW RP Installation RPC/RP Manual 1 Equipment Description This chapter describes all the components involved in the 200mW RP installation, including the 200mW RP and the joint box. 1.1 200mW RP This section represents the 200mW RP installation. 1.1.1 List of Component Parts Items 200mWRP Main Unit Screw for CS installation Mounting Plate Screw for Mounting Plate Spring Washer Plane Washer Nut Spare Fuse Spare Fuse Quantity Model No. and DWG No. EA-7T56 XYN4•F18V 1B14449C 3Z10076A XWA6V XWG6V XNG6AV TSC3A TSC6.3A Company PANASONIC PANASONIC PANASONIC PANASONIC PANASONIC PANASONIC PANASONIC PANASONIC PANASONIC Table 1: Component Parts NOTE: No. 8 and No. 9 are spare fuses. The spare fuse must be inserted in the right place. WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation Figure 1: 200mW RP Unpacking 25July2000 WLL-200mW-RP-IN-1.0 8 200mW RP Installation RPC/RP Manual 1.1.2 Appearance of 200mW RP and Component Parts This section displays the main unit of the 200mW RP and the mounting parts. Scales are not indicated in the diagrams. 1.1.2.1 200mW RP Figure 2: 200mW RP Main Unit WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation Figure 3: Front View of the Main Unit (without the Top Cover) 25July2000 WLL-200mW-RP-IN-1.0 10 200mW RP Installation RPC/RP Manual 1.1.2.2 Mounting Plate Figure 4: 200mW RP Mounting Plate (RP Mounting Base) 1.1.2.3 M4 Screw The M4 screw is used to fix the RP onto the Mounting Plate WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 11 Figure 5: M4 Screw and Its Cross Head 1.1.2.4 M6 Screw The M6 screw is used to mount the Mounting Plate onto the wall. Figure 6: M6 Screw and Its Socket Head 1.1.2.5 M6 Spring Washer Figure 7: M6 Spring Washer 1.1.2.6 M6 Plane Washer Figure 8: M6 Plane Washer 25July2000 WLL-200mW-RP-IN-1.0 12 200mW RP Installation RPC/RP Manual 1.1.2.7 M6 Nut Figure 9: M6 Nut 1.2 Joint Box 1.2.1 List of Component Parts Items Joint Box Screw for Joint Box installation Spring Washer Plane Washer Nut Quantity Model No. And DWG No. EA-Z16092AZ 3Z10076A XWA6V XWG6V XNG6AV Company PANASONIC PANASONIC PANASONIC PANASONIC PANASONIC Table 2: Joint Box Component Parts 1.2.2 Joint Box Unpacking WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 13 Figure 10: Joint Box Unpacking 25July2000 WLL-200mW-RP-IN-1.0 14 200mW RP Installation RPC/RP Manual 1.2.3 Joint Box and Component Parts This diagrams in this section display the joint box and the component parts. Please note that the scales are not indicated in the diagrams. 1.2.3.1 Joint Box Figure 11 shows the joint box. The color is gray and the weight is about 4.1 kg. Figure 11: Joint Box and Open Direction WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 15 1.2.3.2 Hexagon Socket Head Screw The screw is used to fix the joint box to the wall. Figure 12: Hexagon Socket Head Screw 1.2.3.3 M6 Spring Washer Refer to Figure 7. 1.2.3.4 M6 Plane Washer Refer to Figure 8. 1.2.3.5 M6 Nut Refer to Figure 9. 2 Wiring Cables to the Joint Box 2.1 Opening the Joint Box Cover Use a hexagon socket screw key to loosen the four hexagon socket head screws on the four corners of the Joint Box, as displayed in Figure 13. The screws will not drop off from the cabinet. 25July2000 WLL-200mW-RP-IN-1.0 16 200mW RP Installation RPC/RP Manual Figure 13: Loosing the Screws As shown in the figure below, open the cover slowly to ensure that the hinges are not damaged. Remove the pad. Figure 14: Opening the Cover WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 17 2.2 Making Connections Wire each cable as shown in the figure below. Figure 15: Standard Wiring Figure 25July2000 CAUTION: Make sure to install the 2A Circuit Breaker for safety. WLL-200mW-RP-IN-1.0 18 200mW RP Installation RPC/RP Manual WARNING: • • • • • • Keep Commercial Circuit Breakers OFF when installing or reinstalling devices Connect the power source cables completely Do not drop hardware into the openings in the interface Do not work with wet hands Do not wet the inside of the devices when installing Ground the instrument properly (Improper grounding may cause an electric shock) 2.3 Names of the Connection Joints WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 19 Figure 16: Terminals on the Joint Box 2.4 Connecting the AC Power Cables and FG Cables CAUTION: The diameter of the cable connected to this terminal is φ 1.2 to 2.0 mm for single wire. 1. Loosen bushings and put the Power and FG cables through each bushing. 25July2000 WLL-200mW-RP-IN-1.0 20 200mW RP Installation RPC/RP Manual 2. Peel off the cable coating to the length that corresponds to the strip gauge on the terminal, as indicated in Figure 17. Figure 17: Strip Gauge on the Terminal 3. Insert the cables firmly until they come to the end. Figure 18: Inserting the Cable 4. If the cable is connected wrongly, use a proper tool to press down the button of the terminal and pull out the attached cable. Then insert it again. The proper tools that can be used for the purpose include: • • WLL-200mW-RP-IN-1.0 Regular screwdriver (shaft diameter: 6, nose width: 6) Phillips screwdriver (shaft diameter: 4) 25July2000 RPC/RP Manual 200mW RP Installation 21 Figure 19: Tools for Disconnecting the Cable 2.5 Connecting the Line Cables CAUTION: The diameters of the cable connected to this terminal are φ 0.4 to 1.6 mm for single wire and φ 0.3 to 1.25 mm for twisted wire. 1. Put the Line cable through the bushing. 2. Peel off the cable coating to the length that corresponds to the strip gauge on the terminal, as indicated in Figure 20. Figure 20: Strip Gauge on the Terminal 25July2000 WLL-200mW-RP-IN-1.0 22 200mW RP Installation RPC/RP Manual 3. Insert the cables firmly until they come to the end. Figure 21: Inserting the Cable 4. If the cable is connected wrongly, use a proper tool to press down the button of the terminal and pull out the attached cable. Then insert it again. The proper tool that can be used for the purpose is a regular screwdriver (shaft diameter: 3, nose width: 2.6) Figure 22: Tools for Disconnecting the Cable 2.6 Fixing the AC Power Cables and FG Cables Tighten the Power and FG cables' Bushings (3 places) firmly at the torque indicated in Figure 23 or until the interval becomes less than 2mm. WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 23 Figure 23: Power and FG Cable Fixing 25July2000 WLL-200mW-RP-IN-1.0 24 200mW RP Installation RPC/RP Manual 2.7 Fixing the Line Cables As for the line cables, adjust their wiring margin as shown in Figure 24, and bundle and fix them with Insulock Tie (tie band). Cut off the surplus length of Insulock Tie with nipper, etc. Figure 24: Line Cable Fixing NOTE: If the local line cables cannot be wired, use vinyl tape to seal the holes through which the line cables are supposed to come in. WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 25 2.8 Waterproof Treatment of the Line Cables 1. Make sure that the cables are properly wired. 2. To shrink the cables, put your finger into the loop of the spiral core and pull it, as displayed in Figure 25. Pull it around the cable, making sure that the spiral core will not get tangled up with the cables. When the spiral core is pulled out a contraction tube sticks fast around the cables. 3. Make sure that the spiral core is removed completely. Figure 25: Shrinking the Cables 25July2000 WLL-200mW-RP-IN-1.0 26 200mW RP Installation RPC/RP Manual NOTE: If the local line cables cannot be wired, use vinyl tape to seal the holes through which the line cables are supposed to come in. 4. Wrap the self-bonding tape half-lapping and elongate 1.8 to 2.0 times its original length. Don’t over elongate, or it will show signs of cracking. 5. Wrap the protective adhesive PVC tape around the self-bonding tape. Figure 26: Wrapping the Tape WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 27 2.9 Closing the Joint Box Cover 1. Close the cover as shown in the figure below. Take care not to drop the waterproof tube around the lower case. Figure 27: Closing the Joint Box Cover 2. Tighten the screws on the four corners. At first, balance the tightening of all the four screws. Then tighten them firmly as indicated in Figure 28. 25July2000 WLL-200mW-RP-IN-1.0 28 200mW RP Installation RPC/RP Manual Figure 28: Tightening the Screws 3 Opening/Closing Cover of 200mW RP 3.1 Opening the Top Cover 1. Open the caps on the top cover and loose the special screws with a special screwdriver. The screws will not drop off from the top cover. WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 29 Figure 29: Opening the Top Cover 2. Pull the bottom edge of the top cover towards yourself and remove it. The top edge has a hinge. Figure 30: Removing the Cover 25July2000 WLL-200mW-RP-IN-1.0 30 200mW RP Installation RPC/RP Manual 3.2 Fixing the 200mW RP to the Mounting Plate Hook the upper pins of the main unit onto the upper U-notches of the mount plate. Then lift the main unit and fit the lower pins onto the lower U-notches. Finally, fix the 200mW RP main unit onto the mounting plate by tightening the M4 screw. Figure 31: Mounting the 200mW RP WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 3-31 3.3 Closing the Top Cover 1. Hook the top cover to the main unit and push it into place slowly, as shown in Figure 32. Figure 32: Closing the Top Cover 2. Tighten the two special screws with the special screwdriver and close the cap. Figure 33: Tightening the Screws 25July2000 WLL-200mW-RP-IN-1.0 3-32 200mW RP Installation RPC/RP Manual NOTE: Do not use an electric screwdriver to fasten the screws. Fasten the screws with 12 kg.cm – 15 kg.com torque. WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 3-33 Appendix A.1 200mW RP Cable Length Each cable length is shown in Figure 34. The unit is “mm”. Figure 34: Cable Length 25July2000 WLL-200mW-RP-IN-1.0 3-34 200mW RP Installation RPC/RP Manual A.2 The Exchange of the Fuse The Spare fuses must be inserted in the right place, as indicated in Figure 35. Figure 35: Spare Fuse Location WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 3-35 A.3 Electric Connection Figure 36: Electric Connection 25July2000 WLL-200mW-RP-IN-1.0 3-36 200mW RP Installation RPC/RP Manual A.4 Example of Layout Figure 37 illustrates the layout dimension for 200mW RP and the Joint Box. Figure 37: Layout Dimension WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 3-37 A.5 Suitable Size of the Local Cable Figure 38: Local Cable Size 25July2000 WLL-200mW-RP-IN-1.0 3-38 200mW RP Installation RPC/RP Manual A.6 Tape Wrapping If there is something wrong with the bushing, wrap the self-bonding tape and the adhesive PVC tape as shown in the figures below. Figure 39: Wrapping For Broken Spiral-core and Shrinking-tube WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 3-39 A.7 Water Proof of Antenna Cable Figure 40: Water Proof of Antenna Cable 25July2000 WLL-200mW-RP-IN-1.0 3-40 200mW RP Installation RPC/RP Manual Figure 41: Water Proof of Antenna Cable (Continued) A.8 Grounding Protective Earthing Cable Ground the PROTECTIVE EARTHING cable. Earth impedance is less than 100Ω. WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 3-41 Figure 42: Cable Grounding 25July2000 WLL-200mW-RP-IN-1.0 3-42 200mW RP Installation RPC/RP Manual A.9 Installation Image Figure 43: Pole Installation (1) WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 200mW RP Installation 3-43 Figure 44: Pole Installation (2) 25July2000 WLL-200mW-RP-IN-1.0 3-44 200mW RP Installation RPC/RP Manual Figure 45: Rooftop Installation WLL-200mW-RP-IN-1.0 25July2000 RPC/RP Manual 25July2000 200mW RP Installation 3-45 WLL-200mW-RP-IN-1.0
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Producer : Acrobat Distiller 4.05 for Windows Creator : Microsoft Word 9.0 Modify Date : 2001:02:28 10:56:46-05:00 Author : Joseph Zhang Title : 2: General Description Create Date : 2000:07:26 11:02:58 Page Count : 45 Page Mode : UseNoneEXIF Metadata provided by EXIF.tools