Ubiquiti AF2X Digital Point-to-Point Radio User Manual airFiber X User Guide
Ubiquiti Networks, Inc. Digital Point-to-Point Radio airFiber X User Guide
Ubiquiti >
Contents
- 1. user manual Part 1
- 2. user manual Part 2
- 3. user manual Part 3
- 4. user manual Part 4
user manual Part 4
airFiber® X User Guide DATA Port Ethernet Settings DATA Speed This is the speed of the Data port. The default is Auto. The airFiber X radio automatically negotiates transmission parameters, such as speed and duplex, with its counterpart. In this process, the networked devices first share their capabilities and then choose the fastest transmission mode they both support. To manually specify the maximum transmission link speed and duplex mode, select one of the following options: 100 Mbps‑Full, 100 Mbps‑Half, 10 Mbps‑Full, or 10 Mbps‑Half. To disable the Ethernet data port, select Disabled. Note: If Disabled is selected, ensure that the radio is accessible using the Management Ethernet port or over the RF link (with in-band management enabled), or all communication with the radio will be lost. Full-duplex mode allows communication in both directions simultaneously. Half-duplex mode allows communication in one direction at a time, alternating between transmission and reception. Flow Control If enabled, the airFiber X radio generates and responds to Ethernet layer PAUSE frames. The airFiber X radio regulates inbound traffic from the customer’s network to avoid buffer overflows within the airFiber X radio. Flow control has the effect of controlling the inter‑packet spacing of packets headed into the airFiber Data interface. Multicast Filter If enabled, the filter blocks multicast traffic from overloading the CPU when in-band management is enabled. This allows the airFiber X radio to be managed in-band when the customer’s network is carrying large volumes of multicast traffic, such as IPTV. The filter does not block multicast traffic going over the radio; it simply blocks it from reaching the airFiber’s management interface CPU. Track Radio Link If this option is enabled, the airFiber X radio disconnects the Data port’s Ethernet link when the RF link is lost (The Management port is never disabled by this option). The Track Radio Link option is useful because it quickly indicates a “link lost” condition to the customer’s routing equipment (such as a direct connection to OSPF‑enabled routers). • Disabled The Track Radio Link option is disabled by default. The Data port’s Ethernet link will always remain up regardless of the RF link state. Ubiquiti Networks, Inc. Chapter 7: Advanced Tab • Use Timeout Duration This option is designed for use by operators who are using in-band management. Two timers control the Data port’s Ethernet link. RF Link Ethernet Link Notes Goes down for the first time The Ethernet link goes down and remains down for the number of seconds specified by the Link Off Duration timer. Even if the RF link goes back up before the Link Off Duration timer elapses, the Ethernet link remains down. The Ethernet link will then come back up so that the airFiber X radio can be managed even when the RF link is down. Goes down for the second time The Ethernet link remains up as long as time remains on the Link Off Spacing timer. When the Link Off Spacing timer elapses, then the Ethernet link goes down again for the number of seconds specified by the Link Off Duration timer. (This happens only if the RF link is still down.) The Ethernet link’s downtime is long enough to signal to the customer’s routing equipment that the path is lost. The Ethernet link’s uptime is long enough so the operator has enough time to access the airFiber X radio, make configuration changes, and save those changes. Sufficient Ethernet link uptime is vital when a RF link is constantly up and down. If the Use Timeout Duration option is enabled, the Track Radio Link option and the following timers are enabled: -- Link Off Duration The Link Off Duration timer controls the length of time the Data port’s Ethernet link will be down if the RF link goes down. Enter the number of seconds that the Ethernet link should be offline. For example, if this is set to 10 seconds, then when the RF link goes down, the Ethernet link will go down and remain down for 10 seconds (regardless of the RF link state), and then it will go back up. -- Link Off Spacing The Link Off Spacing timer controls the length of time the airFiber X radio will wait before allowing the Data port’s Ethernet link to go down for a second time if the RF link goes down again. Enter the minimum interval (in seconds) between offline events of the Ethernet link, regardless of the RF link status. The value for Link Off Spacing should be larger than the value for Link Off Duration, and it should be enough time for the operator to access the airFiber X radio, make any configuration changes, and apply those changes. Note: If the Link Off Spacing timer is set to 0 seconds, then the Ethernet link will only use the Link Off Duration timer. If the Link Off Duration timer is set to 10 seconds and the RF link goes down, then the Ethernet link will go down for 10 seconds and then go back up regardless of the RF link state. If the RF link is still down, then the Ethernet link will not go down again until the RF link goes back up and then down again. 23 Chapter 7: Advanced Tab Here are a couple of examples involving the use of the Use Timeout Duration option. airFiber® X User Guide MGMT Port Ethernet Settings • Example #1 • Link Off Duration 5 seconds • Link Off Spacing 60 seconds The Data port’s Ethernet link will be initially disconnected when the RF link first goes down. That event will start a 60‑second timer. The Ethernet link will remain offline for 5 seconds (regardless of the RF link status) and then come back online. The Ethernet link will remain online (regardless of the RF link state) until the 60‑second timer expires. • Example #2 • Link Off Duration 20 seconds • Link Off Spacing 120 seconds The Data port’s Ethernet link will be initially disconnected when the RF link first goes down. That event will start a 120‑second timer. The RF link goes back up after 10 seconds; however, that does not affect the Ethernet link. The Ethernet link will remain offline for 20 seconds and then come back online. The RF link goes down again after 60 seconds; however, that does not affect the Ethernet link. The Ethernet link will then remain online until the 120‑second timer expires. MGMT Speed This is the speed of the Management port. By default, the option is Auto. The airFiber X radio automatically negotiates transmission parameters, such as speed and duplex, with its counterpart. In this process, the networked devices first share their capabilities and then choose the fastest transmission mode they both support. To manually specify the maximum transmission link speed and duplex mode, select one of the following options: 100 Mbps‑Full, 100 Mbps-Half, 10 Mbps-Full, or 10 Mbps‑Half. If you are running extra long Ethernet cables, a link speed of 10 Mbps could help to achieve better stability. Full-duplex mode allows communication in both directions simultaneously. Half-duplex mode allows communication in one direction at a time, alternating between transmission and reception. • Enabled This option is designed for use by operators who are not using in-band management. The Track Radio Link option is enabled without timers, so the Data port’s Ethernet link follows the RF link state exactly. If the RF link goes down, then the Ethernet link goes down and remains down until the RF link goes back up. Minimum TX Capacity This is the minimum allowable TX capacity before the link is dropped. If the capacity drops below this threshold, the Ethernet link will be dropped. If set to 0, then capacity will not be used; only the RF link state will be used. Minimum RX Capacity This is the minimum allowable RX capacity before the link is dropped. If the capacity drops below this threshold, the Ethernet link will be dropped. If set to 0, then capacity will not be used; only the RF link state will be used. Capacity Window This is the number of continuous seconds that the radio must remain under the minimum TX or RX capacity before the link is dropped. If set to 0, then as soon as capacity drops below a set limit, the Ethernet link will be dropped. 24 Ubiquiti Networks, Inc. airFiber® X User Guide Chapter 8: Services Tab The Services tab configures system management services: Ping Watchdog, SNMP Agent, Web Server, SSH Server, Telnet Server, NTP Client, Dynamic DNS, System Log, and Device Discovery. Change To save or test your changes, click Change. A new message appears. You have three options: Chapter 8: Services Tab the user-defined constraints, the airFiber X radio will automatically reboot. This option creates a kind of “fail‑proof” mechanism. Ping Watchdog is dedicated to continuous monitoring of the specific connection to the remote host using the Ping tool. The Ping tool works by sending ICMP echo request packets to the target host and listening for ICMP echo response replies. If the defined number of replies is not received, the tool reboots the airFiber X radio. • Apply To immediately save your changes, click Apply. • Test To try the changes without saving them, click Test. To keep the changes, click Apply. If you do not click Apply within 180 seconds (the countdown is displayed), the airFiber X radio times out and resumes its earlier configuration. • Discard To cancel your changes, click Discard. Ping Watchdog Ping Watchdog sets the airFiber X radio to continuously ping a user-defined IP address (it can be the Internet gateway, for example). If it is unable to ping under Ubiquiti Networks, Inc. Ping Watchdog Enables use of Ping Watchdog. • IP Address To Ping Specify the IP address of the target host to be monitored by Ping Watchdog. 25 Chapter 8: Services Tab • Ping Interval Specify the time interval (in seconds) between the ICMP echo requests that are sent by Ping Watchdog. The default value is 300 seconds. airFiber® X User Guide • Location Specify the airFiber X radio’s physical location. Web Server • Startup Delay Specify the initial time delay (in seconds) until the first ICMP echo requests are sent by Ping Watchdog. The default value is 300 seconds. The Startup Delay value should be at least 60 seconds as the network interface and wireless connection initialization takes a considerable amount of time if the airFiber X radio is rebooted. • Failure Count to Reboot Specify the number of ICMP echo response replies. If the specified number of ICMP echo response packets is not received continuously, Ping Watchdog will reboot the airFiber X radio. The default value is 3. • Save Support Info This generates a support information file. SNMP Agent Simple Network Monitor Protocol (SNMP) is an application layer protocol that facilitates the exchange of management information between network devices. Network administrators use SNMP to monitor network‑attached devices for issues that warrant attention. The following Web Server parameters can be set: Secure Connection (HTTPS) If enabled, the Web Server uses secure HTTPS mode. • Secure Server Port If secure HTTPS mode is used, specify the TCP/IP port of the Web Server. Server Port If HTTP mode is used, specify the TCP/IP port of the Web Server. Session Timeout Specifies the maximum timeout before the session expires. Once a session expires, you must log in again using the username and password. SSH Server The airFiber X radio contains an SNMP Agent, which does the following: • Provides an interface for device monitoring using SNMP • Communicates with SNMP management applications for network provisioning • Allows network administrators to monitor network performance and troubleshoot network problems The following SSH Server parameters can be set: SSH Server This option enables SSH access to the airFiber X radio. • Server Port Specify the TCP/IP port of the SSH Server. • Password Authentication If enabled, you must authenticate using administrator credentials to grant SSH access to the airFiber X radio; otherwise, an authorized key is required. For the purpose of equipment identification, configure the SNMP Agent with contact and location information: • Authorized Keys Click Edit to import a public key file for SSH access to the airFiber X radio instead of using an admin password. SNMP Agent Enables the SNMP Agent. • SNMP Community Specify the SNMP community string. It is required to authenticate access to Management Information Base (MIB) objects and functions as an embedded password. The airFiber X radio also supports a read-only community string; authorized management stations have read access to all the objects in the MIB except the community strings, but do not have write access. The airFiber X radio supports SNMP v1. The default SNMP Community is public. • Contact Specify the contact who should be notified in case of emergency. 26 -- Choose File Click Choose File to locate the new key file. Select the file and click Open. -- Import Imports the file for SSH access. -- Enabled Enables the specific key. All the added keys are saved in the system configuration file; however, Ubiquiti Networks, Inc. airFiber® X User Guide Chapter 8: Services Tab only the enabled keys are active on the airFiber X radio. -- Type Displays the type of key. -- Key Displays the key. -- Comment You can enter a brief description of the key. -- Action You have the following options: • Add Adds a public key file. • Edit Make changes to a public key file. Click Save to save your changes. • Del Deletes a public key file. Dynamic DNS If enabled, the airFiber X radio allows communications with the DDNS server. • Host Name Enter the host name of the DDNS server. • Username Enter the user name of the DDNS account. -- Save Saves your changes. • Password Enter the password of the DDNS account. -- Close Discards your changes. • Show Check the box to display the password characters. Telnet Server System Log The following Telnet Server parameters can be set: Telnet Server This option activates Telnet access to the airFiber X radio. • Server Port Specify the TCP/IP port of the Telnet Server. NTP Client Network Time Protocol (NTP) is a protocol for synchronizing the clocks of computer systems over packet-switched, variable-latency data networks. You can use it to set the system time on the airFiber X radio. If the Log option is enabled, then the system time is reported next to every log entry that registers a system event. NTP Client Enables the airFiber X radio to obtain the system time from a time server on the Internet. • NTP Server Specify the IP address or domain name of the NTP server. Dynamic DNS Domain Name System (DNS) translates domain names to IP addresses; Each DNS server on the Internet holds these mappings in its respective DNS database. Dynamic Domain Name System (DDNS) is a network service that notifies the DNS server in real time of any changes in the airFiber X radio’s IP settings. Even if the airFiber X radio’s IP address changes, you can still access the airFiber X radio through its domain name. Ubiquiti Networks, Inc. System Log This option enables the registration routine of system log (syslog) messages. By default it is disabled. • Remote Log Enables the syslog remote sending function. System log messages are sent to a remote server, which is specified in the Remote Log IP Address and Remote Log Port fields. -- Remote Log IP Address The host IP address that receives syslog messages. Properly configure the remote host to receive syslog protocol messages. -- Remote Log Port The TCP/IP port that receives syslog messages. 514 is the default port for the commonly used system message logging utilities. Every logged message contains at least a system time and host name. Usually a specific service name that generates the system event is also specified within the message. Messages from different services have different contexts and different levels of detail. Usually error, warning, or informational system service messages are reported; however, more detailed debug level messages can also be reported. The more detailed the system messages reported, the greater the volume of log messages generated. 27 Chapter 8: Services Tab airFiber® X User Guide Device Discovery Discovery Enables device discovery, so the airFiber X radio can be discovered by other Ubiquiti devices through the Discovery tool. CDP Enables Cisco Discovery Protocol (CDP) communications, so the airFiber X radio can send out CDP packets to share its information. 28 Ubiquiti Networks, Inc. airFiber® X User Guide Chapter 9: System Tab The System tab contains administrative options. This page enables the administrator to reboot the airFiber X radio, reset it to factory defaults, upload new firmware, back up or update the configuration, and configure the administrator account. Chapter 9: System Tab Firmware Update The controls in this section manage firmware maintenance. Change To save or test your changes, click Change. A new message appears. You have three options: Firmware Version Displays the current firmware version. • Apply To immediately save your changes, click Apply. Build Number Displays the build number of the firmware version. • Test To try the changes without saving them, click Test. To keep the changes, click Apply. If you do not click Apply within 180 seconds (the countdown is displayed), the airFiber X radio times out and resumes its earlier configuration. • Discard To cancel your changes, click Discard. Check for Updates By default, the firmware automatically checks for updates. To manually check for an update, click Check Now. Upload Firmware Click this button to update the airFiber X radio with new firmware. The airFiber X radio firmware update is compatible with all configuration settings. The system configuration is preserved while the airFiber X radio is updated with a new firmware version. However, we recommend that you back up your current system configuration before updating the firmware. Ubiquiti Networks, Inc. 29 Chapter 9: System Tab This is a three-step procedure: 1. Click Choose File to locate the new firmware file. Select the file and click Open. 2. Click Upload to upload the new firmware to the airFiber X radio. airFiber® X User Guide System Accounts You can change the administrator password to protect your device from unauthorized changes. We recommend that you change the default administrator password when initially configuring the device. 3. The Uploaded Firmware Version is displayed. Click Update to confirm. If the firmware update is in process, you can close the firmware update window, but this does not cancel the firmware update. Please be patient, as the firmware update routine can take three to seven minutes. You cannot access the airFiber X radio until the firmware update routine is completed. WARNING: Do not power off, do not reboot, and do not disconnect the airFiber X radio from the power supply during the firmware update process as these actions will damage the airFiber X radio! Device The Device Name (host name) is the system-wide device identifier. The SNMP agent reports it to authorized management stations. The Device Name will be used in popular router operating systems, registration screens, and discovery tools. Administrator Username Specifies the name of the administrator. Key icon Click this icon to change the administrator password. • Current Password Enter the current password for the administrator account. It is required to change the Password or Administrator Username. • New Password Enter the new password for the administrator account. • Verify New Password Re-enter the new password for the administrator account. Note: The password length is 8 characters maximum; passwords exceeding 8 characters will be truncated. Device Name Specifies the host name. Interface Language Allows you to select the language displayed in the web management interface. English is the default language. Date Settings Read-Only Account Check the box to enable the read‑only account, which can only view the Main tab. Configure the username and password to protect your device from unauthorized changes. • Read-Only Account Name Specifies the name of the system user. • Key icon Click this icon to change the read-only password. -- New Password Enter the new password for the read‑only account. -- Show Check the box to display the read-only password characters. Time Zone Specifies the time zone in relation to Greenwich Mean Time (GMT). Miscellaneous Startup Date When enabled, you are able to change the airFiber X radio’s startup date. • Startup Date Specifies the airFiber X radio’s startup date. Click the Calendar icon or manually enter the date in the following format: 2-digit month/2-digit day/4‑digit year. For example, for January 5, 2014, enter 01/05/2014 in the field. 30 Reset Button To allow use of the airFiber X radio’s physical reset button, check the box. To prevent an accidental reset to default settings, uncheck the box. Note: You can reset the airFiber X radio to default settings via the airFiber Configuration Interface. Go to the System tab > Reset to Defaults. Ubiquiti Networks, Inc. airFiber® X User Guide Location After the on-board GPS determines the location of the airFiber X radio, its latitude and longitude are displayed. If the GPS does not have a fix on its location, then “Searching for Satellites” will be displayed. Latitude The latitude of the airFiber X radio’s location is displayed. Longitude The longitude of the airFiber X radio’s location is displayed. Chapter 9: System Tab We recommend that you back up your current system configuration before uploading the new configuration. Upload Click this button to upload the new configuration file to the airFiber X radio. Click Apply to confirm. After the airFiber X radio reboots, the settings of the new configuration are displayed in the Wireless, Network, Advanced, Services, and System tabs of the airFiber Configuration Interface. Reset to Factory Defaults Resets the airFiber X radio to the factory default settings. This option will reboot the airFiber X radio, and all factory default settings will be restored. We recommend that you back up your current system configuration before resetting the airFiber X radio to its defaults. Device Maintenance The controls in this section manage the airFiber X radio maintenance routines: reboot and support information reports. Reboot Device Initiates a full reboot cycle of the airFiber X radio. Reboot is the same as the hardware reboot, which is similar to the power-off and power-on cycle. The system configuration stays the same after the reboot cycle completes. Any changes that have not been applied are lost. Support Info This generates a support information file that the Ubiquiti support engineers can use when providing customer support. This file only needs to be generated at their request. Configuration Management The controls in this section manage the airFiber X radio configuration routines and the option to reset the airFiber X radio to factory default settings. The airFiber X radio configuration is stored in a plain text file (.cfg file). You can back up, restore, or update the system configuration file: Back Up Configuration Click Download to download the current system configuration file. Upload Configuration Click Choose File to locate the new configuration file. Select the file and click Open. Ubiquiti Networks, Inc. 31 Chapter 10: Tools Chapter 10: Tools Each tab of the airFiber Configuration Interface contains network administration and monitoring tools. Click the Tools drop‑down list at the top right corner of the page. Align Antenna Use the Align Antenna tool to point and optimize the antenna in the direction of maximum link signal. The Antenna Alignment window is designed to refresh every 250 milliseconds. 32 airFiber® X User Guide Chain 0/1 (Actual/Ideal) Displays the absolute power level (in dBm) of the received signal for each chain. Note: If “Overload” is displayed to indicate an overload condition, identify and eliminate any sources of strong in‑band interference. Remote Chain 0/1 (Actual/Ideal) Displays the absolute power level (in dBm) of the received signal for each chain of the remote airFiber X radio. Max Signal Displays the maximum signal strength (in dBm). To adjust the range of the Max Signal meter, use the slider or manually enter the new value. If you reduce the range, the color change will be more sensitive to signal fluctuations, indicating the offset of the maximum indicator value and the scale itself. Ubiquiti Networks, Inc. airFiber® X User Guide Discovery The Device Discovery tool searches for all Ubiquiti devices on your network. The Search field automatically filters devices containing specified names or numbers as you enter them. Chapter 10: Tools Packet Count Enter the number of packets to send for the ping test. Packet Size Specify the size of the packet. Start Click this button to start the test. Packet loss statistics and latency time evaluation are displayed after the test is completed. Traceroute The Traceroute tool traces the hops from the airFiber X radio to a specified outgoing IP address. Use this tool to find the route taken by ICMP packets across the network to the destination host. It reports the MAC Address, Device Name, Mode, SSID, Product type, Firmware version, and IP Address for each Ubiquiti device. To access a device configuration through its web management interface, click the device’s IP address. To refresh the window, click Scan. Ping You can ping other devices on the network directly from the airFiber X radio. The Ping tool uses ICMP packets to check the preliminary link quality and packet latency estimation between two network devices. Destination Host Enter the IP address of the destination host. Resolve IP Addresses Select this option to resolve the IP addresses symbolically rather than numerically. Start Click this button to start the test. Responses are displayed after the test is completed. airView Use the airView Spectrum Analyzer to analyze the noise environment of the radio spectrum and intelligently select the optimal frequency to install a PtP airFiber link. There are two system requirements for the airView Spectrum Analyzer: • Your system is connected to the device via Ethernet. Launching airView will terminate all wireless connections on the device. • Java Runtime Environment 1.6 (or above) is required on your client machine to use airView. On first use, the following window appears. Network Ping Select Destination IP You have two options: • Select a remote system IP from the drop-down list, which is generated automatically. • Select specify manually and enter the IP address in the field displayed below the option. Ubiquiti Networks, Inc. • Do NOT warn me about this in the future Check the box to bypass this window in future launches of the airView Spectrum Analyzer. 33 Chapter 10: Tools • Launch airView Click Launch airView to download the Java Network Launch Protocol (jnlp) file and complete the launch of airView. airFiber® X User Guide View Menu Enable Chart Panel 1 (top) Displays the Waterfall or Channel Usage chart in Chart Panel 1, depending on which option you have selected in Preferences. This time‑based graph shows the aggregate energy collected or channel usage for each frequency since the start of the airView session. Enable Chart Panel 2 (middle) Displays the Waveform chart in Chart Panel 2. This time-based graph shows the RF signature of the noise environment since the start of the airView session. The energy color designates its amplitude. Cooler colors represent lower energy levels (with blue representing the lowest levels) in that frequency bin, and warmer colors (yellow, orange, or red) represent higher energy levels in that frequency bin. Main View Device Displays the device name, MAC (Media Access Control) address, and IP address of the device running airView. Total RF Frames Displays the total number of Radio Frequency (RF) frames gathered since the start of the airView session or since the Reset All Data button was last clicked. FPS Displays the total number of frames per second (FPS) gathered since the start of the airView session or since the Reset All Data button was last clicked. The wider the interval amplitude, the fewer the FPS will be gathered. Enable Chart Panel 3 (bottom) Displays the Real-time chart (traditional spectrum analyzer) in Chart Panel 3. Energy (in dBm) is shown in real time as a function of frequency. Note: Energy is the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Clear All Markers Resets all previously assigned markers. Markers are assigned by clicking a point, which corresponds with a frequency on the Real-time chart. Preferences Changes airView settings, such as enabling or disabling charts and traces, or specifying the frequency interval. Preferences Select View > Preferences to display the Preferences airView Spectrum Analyzer window. Reset All Data Click to reset all gathered data. Use this option to analyze the spectrum for another location or address. File Menu Click Exit to end the airView session. 34 Ubiquiti Networks, Inc. airFiber® X User Guide Charts Chapter 10: Tools Enable Waveform chart (middle) Check the box to enable the middle chart. This time-based graph shows the RF signature of the noise environment since the start of the airView session. The energy color designates its amplitude. Cooler colors represent lower energy levels (with blue representing the lowest levels) in that frequency bin, and warmer colors (yellow, orange, or red) represent higher energy levels in that frequency bin. The spectral view over time will display the steady-state RF energy signature of a given environment. Enable Real-time chart (bottom) Check the box to enable the bottom chart. This graph displays a traditional spectrum analyzer in which energy (in dBm) is shown in real time as a function of frequency. There are three traces in this view: • Current (Yellow) Shows the real-time energy seen by the device as a function of frequency. • Average (Green) Shows the running average energy across frequency. • Maximum (Blue) Shows updates and maximum power levels across frequency. Real-Time Traces Enable top chart Check the box to enable the top chart. Select the desired chart to display in the top chart panel on the main view. There are two options: • Waterfall This time-based graph shows the aggregate energy collected for each frequency since the start of the airView session. The energy color designates its amplitude. Cooler colors represent lower energy levels (with blue representing the lowest levels) in that frequency bin, and warmer colors (yellow, orange, or red) represent higher energy levels in that frequency bin. The Waterfall View’s legend (top-right corner) provides a numerical guide associating the various colors to power levels (in dBm). The low end of that legend (left) is always adjusted to the calculated noise floor, and the high end (right) is set to the highest detected power level since the start of the airView session. • Channel Usage For each channel, a bar displays a percentage showing the relative “crowdedness” of that specific channel. To calculate this percentage, the airView Spectrum Analyzer analyzes both the popularity and strength of RF energy in that channel since the start of an airView session. Note: airFiber X radio channels are not related to Wi‑Fi channels which are determined by IEEE standards. airFiber X radio channels are numbered consecutively starting with 0 and are 28 MHz in width. Ubiquiti Networks, Inc. The following settings apply only to the Real-time chart: Current Real-time Trace Check the Enable box to enable the real-time trace. When enabled, the yellow outline on the Real-time chart represents the real-time power level of each frequency. The refresh speed depends on the FPS. 35 Chapter 10: Tools airFiber® X User Guide Averages Trace Check the Enable box to enable the averages trace. When enabled, the averages trace is represented by the green area on the Real-time chart, which displays the average received power level data since the start of the airView session. To enable a shaded green area, check the Shaded Area box. To display only a green outline without the shaded area, uncheck the Shaded Area box. Maximum Power Levels Trace Check the Enable box to enable the maximum power trace. When enabled, the maximum power trace is represented by the blue area on the Real-time chart, which displays the maximum received power level data since the start of the airView session. To enable a shaded blue area, check the Shaded Area box. To display only a blue outline without the shaded area, uncheck the Shaded Area box. Frequency Range Select the amplitude of the frequency interval to be scanned from the Frequency Range drop‑down list. Available frequencies are devicedependent. There are pre-defined ranges for the most popular bands. You can enter a custom range; select Custom Range from the Frequency Range drop-down list and enter the desired values in the Start and End fields. 36 Ubiquiti Networks, Inc. airFiber® X User Guide Appendix A: Specifications Appendix A: Specifications airFiber AF‑2X Dimensions Weight RF Connectors GPS Antenna Max. Conducted TX Power Power Supply Power Method Mounting Certifications Operating Temperature 224 x 82 x 48 mm (8.82 x 3.23 x 1.89") 0.35 kg (0.77 lb) (2) RP-SMA Weatherproof (CH0, CH1) (1) SMA Weatherproof (GPS) External, Magnetic Base 29 dBm (Depends on Regulatory Region) 24V, 1A PoE Gigabit Adapter (Included) Passive Power over Ethernet Rocket Mount Compatible GPS Pole Mount (Included) FCC Part 15.247 CE EN 300328 v1.8.1 -40 to 55° C (-40 to 131° F) Networking Interface Data Port Management Port (1) 10/100/1000 Ethernet Port (1) 10/100 Ethernet Port System Maximum Throughput Encryption OS Wireless Modes 500 Mbps 128-bit AES airOS F Master/Slave Radio Operating Frequency 2400-2500 MHz (Depends on Regulatory Region) Frequency Accuracy ± 2.5 ppm without GPS Synchronization ± 0.2 ppm with GPS Synchronization Channel Bandwidth 3.5 MHz, 5 MHz, 7.0 MHz, 10 MHz, 14 MHz, 20 MHz, 28 MHz, 30 MHz, 40 MHz, 50 MHz, and 56 MHz Selectable Programmable Uplink and Downlink Duty Cycles Ubiquiti Networks, Inc. 37 Appendix A: Specifications airFiber® X User Guide airFiber AF‑3X Dimensions Weight RF Connectors GPS Antenna Max. Conducted TX Power Power Supply Power Method Mounting Certifications Operating Temperature 224 x 82 x 48 mm (8.82 x 3.23 x 1.89") 0.35 kg (0.77 lb) (2) RP-SMA Weatherproof (CH0, CH1) (1) SMA Weatherproof (GPS) External, Magnetic Base 29 dBm (Depends on Regulatory Region) 24V, 1A PoE Gigabit Adapter (Included) Passive Power over Ethernet Rocket Mount Compatible GPS Pole Mount (Included) FCC Part 90 Z CE EN 302 217-2-2 -40 to 55° C (-40 to 131° F) Networking Interface Data Port Management Port (1) 10/100/1000 Ethernet Port (1) 10/100 Ethernet Port System Maximum Throughput Encryption OS Wireless Modes 500 Mbps 128-bit AES airOS F Master/Slave Radio Operating Frequency 3300-3900 MHz (Depends on Regulatory Region) Frequency Accuracy ± 2.5 ppm without GPS Synchronization ± 0.2 ppm with GPS Synchronization Channel Bandwidth 3.5 MHz, 5 MHz, 7.0 MHz, 10 MHz, 14 MHz, 20 MHz, 28 MHz, 30 MHz, 40 MHz, 50 MHz, and 56 MHz Selectable Programmable Uplink and Downlink Duty Cycles 38 Ubiquiti Networks, Inc. airFiber® X User Guide Appendix A: Specifications airFiber AF‑5X Dimensions Weight RF Connectors GPS Antenna Max. Conducted TX Power Power Supply Power Method Mounting Certifications Operating Temperature 224 x 82 x 48 mm (8.82 x 3.23 x 1.89") 0.35 kg (0.77 lb) (2) RP-SMA Weatherproof (CH0, CH1) (1) SMA Weatherproof (GPS) External, Magnetic Base 26 dBm (Depends on Regulatory Region) 24V, 1A PoE Gigabit Adapter (Included) Passive Power over Ethernet Rocket Mount Compatible GPS Pole Mount (Included) FCC Part 15.407 CE EN 302502 v1.2.1, EN 301 893 v1.7.1 -40 to 55° C (-40 to 131° F) Networking Interface Data Port Management Port (1) 10/100/1000 Ethernet Port (1) 10/100 Ethernet Port System Maximum Throughput Encryption OS Wireless Modes 500 Mbps 128-bit AES airOS F Master/Slave Radio Operating Frequency 5150-5950 MHz (Depends on Regulatory Region) Frequency Accuracy ± 2.5 ppm without GPS Synchronization ± 0.2 ppm with GPS Synchronization Channel Bandwidth 10 MHz, 20 MHz, 30 MHz, 40 MHz, 50 MHz Selectable Programmable Uplink and Downlink Duty Cycles Ubiquiti Networks, Inc. 39 Appendix B: Listen Before Talk Appendix B: Listen Before Talk Note: This appendix applies to the airFiber AF-3X radio only. Introduction Listen Before Talk (LBT) is a requirement for the 3.6 GHz band in North America and Canada. Because exclusive licenses for the 3650-3700 MHz band are not granted within the United States, operators must take steps to minimize potential interference in this band. LBT refers to a contention-based protocol (CBP) that requires a device to check if the transmission channel is in use (listen) before it can initiate a transmission (talk). FCC standards that relate to LBT include the following: • FCC Part 90, Subpart Z requires 3.6 GHz systems to implement a contention-based protocol to provide LBT capability. This same requirement has also been adopted by Industry Canada (IC). • FCC Part 90, Subpart Z defines two categories of contention-based protocols, restricted and unrestricted: -- Restricted contention-based protocol This is a protocol that can detect interference from products that use a similar contention technology. Systems using a restricted contention-based protocol operate in the lower 25 MHz of the frequency band (36503675 MHz). -- Unrestricted contention-based protocol This is a protocol that can detect interference from products that use a dissimilar contention technology. Systems using an unrestricted contention-based protocol use the full 50 MHz (3650-3700 MHz) of the frequency band. Unrestricted Protocol Description The AF-3X Master/Slave system uses dedicated logic for the LBT protocol, which is embedded into a TDD frame structure. Energy detection is done at the beginning of the TX defined by the frame structure of the air interface, at intervals of 2.0, 2.5, 4.0, or 5.0 ms for compatibility between various other Part 90Z radio devices. Threshold Detection To Determine Occupancy The AF-3X averages the energy detected over a fixed listen time and compares it to a preconfigured threshold value. This threshold is configured for values that are within the linear portion of the radio’s Receive Signal Strength Indicator (RSSI) dynamic range. The energy detection threshold is proportional to the transmitter’s maximum transmit power. For example, if the transmitter’s EIRP is 23 dBm, then the detection threshold at the receiver’s input (assuming antenna gain of 0 dBi) is -73 dBm/MHz. 40 airFiber® X User Guide The detection threshold is adjusted as follows: DT = -73 dBm/MHz + 10log10(B) + 23 – PT + A where: DT PT Detection Threshold in dBm Monitored bandwidth in MHz Maximum transmit power in dBm EIRP Receive antenna gain in dBi The receive antenna gain A is set equal to the external antenna gain. The following are set by the operator during the configuration of the AF-3X radio: • maximum desired EIRP power PT • external antenna gain A • channel bandwidth B The AF-3X ensures that the sum of the actual conducted power and the external antenna gain used to calculate PT does not exceed the regulatory EIRP limit. The Master/Slave device makes an average measurement during its Tx and samples the channel every frame (typically 2.0 ms) to accumulate a co-channel signal measurement. A typical accumulation period is 5 µs. The bandwidth used for all channel occupancy measurements is the same bandwidth used for system operation and is configurable for values that range from 3.5 MHz to 40 MHz. The detection threshold is configured to scale automatically based on the in-use modulation level that the system negotiates. The threshold level is automatically set by the radio to meet regulatory requirements. All threshold levels are normalized to a 0 dBi reference level. The detection system uses the same hardware as the actual radio lower-level software code and is therefore operational over the same power range. The AF-3X point-to-point system employs a proprietary media access layer (MAC) that utilizes a TDD scheduled transmission which is synchronized. Both the Master and Slave employ a threshold detection mechanism to monitor for other systems running within a selected channel. Action Taken When Occupancy is Determined Upon detection of occupancy, the Master will cease transmission. It will continue to monitor the channel to see if at any point that it becomes available. Hidden-node problems are avoided by the AF-3X system’s proprietary media access control (MAC) layer that utilizes a TDD scheduled transmission (a synchronized framed transmission). The Slave device cannot transmit until it is allocated bandwidth from the Master device. If the Master device detects co-channel signals, the uplink for the scheduled slot allocation is not granted to the Slave, preventing the Slave from transmitting. Since permission to transmit is granted by the Master, there is no hidden node problem like that experienced by Wi-Fi systems which employ a contention-based protocol. Ubiquiti Networks, Inc. airFiber® X User Guide Appendix B: Listen Before Talk Opportunities for Other Transmitters to Operate No differences are performed between start-up mode and operational mode. The Master/Slave device goes into an energy scanning mode where it is allowed to do one full cycle of energy detection before it is allowed to transmit. The scan is a mode where the average energy is accumulated to compare against the programmed detection threshold. If the energy detected is less than the detection threshold, the Master/Slave device is allowed to make a transmission. In normal operational mode the system does not allow any transmission once the threshold has been detected. Once the energy is no longer present will the system begin to transmit again. The Master and Slave uses the energy detected prior to each transmit frame to control the muting of the transmit function. At any load level (no load, typical, or overload), the system transmits data based on the configuration for the uplink/downlink ratio The same amount of bandwidth is reserved for channel detection, so performance remains unaffected. If there are two AF-3X systems on a co-channel, they would share the spectrum as follows: • Since the system is a synchronized frame-based system, both systems would operate effectively with each other because each system can be configured to transmit and receive at the same point in time. The system uses a GPS synchronization to time-align the start-of-frame for all systems deployed. • If the users configure the number of uplink and downlink slots and the duty cycle (uplink/downlink ratio) in an identical manner and each system uses the same set of uncommitted uplink slots for the detection sampling interval, then the two systems will co-exist with no knowledge of the others presence. • Each system listens prior to transmit and if it detects activity yields to the other system. • The system will shut down when the accumulated energy is above the detection threshold and will continue to transmit if it is below the detection threshold. When the co-channel system is clear of the channel then the target system will go back into regular operation. Regular operation will consist of a constant averaging of the energy detected in the uplink slots. Ubiquiti Networks, Inc. 41 Appendix C: Safety Notices airFiber® X User Guide Appendix C: Safety Notices 1. Read, follow, and keep these instructions. 2. Heed all warnings. 3. Only use attachments/accessories specified by the manufacturer. WARNING: Do not use this product in location that can be submerged by water. WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning. Electrical Safety Information 1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed. 2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician. 3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet. a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire. b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death. c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment. d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection. e. Protective bonding must be installed in accordance with local national wiring rules and regulations. 42 Ubiquiti Networks, Inc. airFiber® X User Guide Appendix D: Warranty Limited Warranty UBIQUITI NETWORKS, Inc (“UBIQUITI NETWORKS”) warrants that the product(s) furnished hereunder (the “Product(s)”) shall be free from defects in material and workmanship for a period of one (1) year from the date of shipment by UBIQUITI NETWORKS under normal use and operation. UBIQUITI NETWORKS’ sole and exclusive obligation and liability under the foregoing warranty shall be for UBIQUITI NETWORKS, at its discretion, to repair or replace any Product that fails to conform to the above warranty during the above warranty period. The expense of removal and reinstallation of any Product is not included in this warranty. The warranty period of any repaired or replaced Product shall not extend beyond its original term. Warranty Conditions The above warranty does not apply if the Product: (I) has been modified and/or altered, or an addition made thereto, except by Ubiquiti Networks, or Ubiquiti Networks’ authorized representatives, or as approved by Ubiquiti Networks in writing; (II) has been painted, rebranded or physically modified in any way; (III) has been damaged due to errors or defects in cabling; (IV) has been subjected to misuse, abuse, negligence, abnormal physical, electromagnetic or electrical stress, including lightning strikes, or accident; (V) has been damaged or impaired as a result of using third party firmware; (VI) has no original Ubiquiti MAC label, or is missing any other original Ubiquiti label(s); or (VII) has not been received by Ubiquiti within 30 days of issuance of the RMA. In addition, the above warranty shall apply only if: the product has been properly installed and used at all times in accordance, and in all material respects, with the applicable Product documentation; all Ethernet cabling runs use CAT5 (or above), and for outdoor installations, shielded Ethernet cabling is used, and for indoor installations, indoor cabling requirements are followed. WARNING: Failure to properly ground your airFiber units will void your warranty. (Please follow the instructions on “Install a Ground Wire” on page 5 for installation of the ground wires.) Ubiquiti Networks, Inc. Appendix D: Warranty Returns No Products will be accepted for replacement or repair without obtaining a Return Materials Authorization (RMA) number from UBIQUITI NETWORKS during the warranty period, and the Products being received at UBIQUITI NETWORKS’ facility freight prepaid in accordance with the RMA process of UBIQUITI NETWORKS. Products returned without an RMA number will not be processed and will be returned freight collect or subject to disposal. Information on the RMA process and obtaining an RMA number can be found at: www.ubnt.com/support/warranty. Disclaimer EXCEPT FOR ANY EXPRESS WARRANTIES PROVIDED HEREIN, UBIQUITI NETWORKS, ITS AFFILIATES, AND ITS AND THEIR THIRD PARTY DATA, SERVICE, SOFTWARE AND HARDWARE PROVIDERS HEREBY DISCLAIM AND MAKE NO OTHER REPRESENTATION OR WARRANTY OF ANY KIND, EXPRESS, IMPLIED OR STATUTORY, INCLUDING, BUT NOT LIMITED TO, REPRESENTATIONS, GUARANTEES, OR WARRANTIES OF MERCHANTABILITY, ACCURACY, QUALITY OF SERVICE OR RESULTS, AVAILABILITY, SATISFACTORY QUALITY, LACK OF VIRUSES, QUIET ENJOYMENT, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT AND ANY WARRANTIES ARISING FROM ANY COURSE OF DEALING, USAGE OR TRADE PRACTICE IN CONNECTION WITH SUCH PRODUCTS AND SERVICES. BUYER ACKNOWLEDGES THAT NEITHER UBIQUITI NETWORKS NOR ITS THIRD PARTY PROVIDERS CONTROL BUYER’S EQUIPMENT OR THE TRANSFER OF DATA OVER COMMUNICATIONS FACILITIES, INCLUDING THE INTERNET, AND THAT THE PRODUCTS AND SERVICES MAY BE SUBJECT TO LIMITATIONS, INTERRUPTIONS, DELAYS, CANCELLATIONS AND OTHER PROBLEMS INHERENT IN THE USE OF COMMUNICATIONS FACILITIES. UBIQUITI NETWORKS, ITS AFFILIATES AND ITS AND THEIR THIRD PARTY PROVIDERS ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS, DELAYS, CANCELLATIONS, DELIVERY FAILURES, DATA LOSS, CONTENT CORRUPTION, PACKET LOSS, OR OTHER DAMAGE RESULTING FROM ANY OF THE FOREGOING. In addition, UBIQUITI NETWORKS does not warrant that the operation of the Products will be errorfree or that operation will be uninterrupted. In no event shall UBIQUITI NETWORKS be responsible for damages or claims of any nature or description relating to system performance, including coverage, buyer’s selection of products (including the Products) for buyer’s application and/or failure of products (including the Products) to meet government or regulatory requirements. 43 Appendix D: Warranty airFiber® X User Guide Limitation of Liability EXCEPT TO THE EXTENT PROHIBITED BY LOCAL LAW, IN NO EVENT WILL UBIQUITI OR ITS SUBSIDIARIES, AFFILIATES OR SUPPLIERS BE LIABLE FOR DIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES (INCLUDING LOST PROFIT, LOST DATA, OR DOWNTIME COSTS), ARISING OUT OF THE USE, INABILITY TO USE, OR THE RESULTS OF USE OF THE PRODUCT, WHETHER BASED IN WARRANTY, CONTRACT, TORT OR OTHER LEGAL THEORY, AND WHETHER OR NOT ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Note Some countries, states and provinces do not allow exclusions of implied warranties or conditions, so the above exclusion may not apply to you. You may have other rights that vary from country to country, state to state, or province to province. Some countries, states and provinces do not allow the exclusion or limitation of liability for incidental or consequential damages, so the above limitation may not apply to you. EXCEPT TO THE EXTENT ALLOWED BY LOCAL LAW, THESE WARRANTY TERMS DO NOT EXCLUDE, RESTRICT OR MODIFY, AND ARE IN ADDITION TO, THE MANDATORY STATUTORY RIGHTS APPLICABLE TO THE LICENSE OF ANY SOFTWARE (EMBEDDED IN THE PRODUCT) TO YOU. The United Nations Convention on Contracts for the International Sale of Goods shall not apply to any transactions regarding the sale of the Products. 44 Ubiquiti Networks, Inc. airFiber® X User Guide Appendix E: Compliance Information Installer Compliance Responsibility Devices must be professionally installed and it is the professional installer’s responsibility to make sure the device is operated within local country regulatory requirements. airFiber AF-2X FCC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This radio transmitter (FCC: SWX-AF2X) has been approved by FCC to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Appendix E: Compliance Information Industry Canada CAN ICES-3(B)/NMB-3(B) To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter (IC: 6545A-AF2X) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. • Dish antenna, gain: 6 dBi • Dish antenna, gain: 24 dBi CAN ICES-3(B)/NMB-3(B) Pour réduire le risque d’interférence aux autres utilisateurs, le type d’antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie. Cet appareil est conforme à la norme RSS Industrie Canada exempts de licence norme(s). Son fonctionnement est soumis aux deux conditions suivantes: 1. Cet appareil ne peut pas provoquer d’interférences et 2. Cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif. Cet émetteur radio (IC: 6545A-AF2X) a été approuvée par Industrie Canada pour l’exploitation avec l’antenne types énumérés ci-dessous avec le gain maximal admissible et requis l’impédance de l’antenne pour chaque type d’antenne indiqué. Types d’antenne non inclus dans cette liste, ayant un gain supérieur au gain maximal indiqué pour ce type, sont strictement interdits pour une utilisation avec cet appareil. Immédiatement suite à la remarque, le fabricant doit fournir une liste de tous les types d’antenne approuvé pour une utilisation avec l’émetteur, ce qui indique le gain maximal d’antenne permis (en dBi) et requis d’impédance pour chacun. • Antenne parabolique, gain: 6 dBi • Antenne parabolique, gain: 24 dBi • Dish antenna, gain: 6 dBi • Dish antenna, gain: 24 dBi Ubiquiti Networks, Inc. 45 Appendix E: Compliance Information airFiber® X User Guide RF Exposure Warning airFiber AF-3X The antennas used for this transmitter must be installed to provide a separation distance of at least 97 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter. FCC Les antennes utilisées pour ce transmetteur doivent être installé en considérant une distance de séparation de toute personnes d’au moins 97 cm et ne doivent pas être localisé ou utilisé en conflit avec tout autre antenne ou transmetteur. Australia and New Zealand Warning: This is a Class B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This radio transmitter (FCC: SWX-AF3X) has been approved by FCC to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. • Dish antenna, gain: 12 dBi • Dish antenna, gain: 26 dBi • Dish antenna, gain: 29 dBi 46 Ubiquiti Networks, Inc. airFiber® X User Guide Appendix E: Compliance Information Industry Canada RF Exposure Warning CAN ICES-3(B)/NMB-3(B) The antennas used for this transmitter must be installed to provide a separation distance of at least 126 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter (IC: 6545A-AF3X) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. • Dish antenna, gain: 12 dBi • Dish antenna, gain: 26 dBi • Dish antenna, gain: 29 dBi Les antennes utilisées pour ce transmetteur doivent être installé en considérant une distance de séparation de toute personnes d’au moins 126 cm et ne doivent pas être localisé ou utilisé en conflit avec tout autre antenne ou transmetteur. Australia and New Zealand Warning: This is a Class B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it. CAN ICES-3(B)/NMB-3(B) Pour réduire le risque d’interférence aux autres utilisateurs, le type d’antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie. Cet appareil est conforme à la norme RSS Industrie Canada exempts de licence norme(s). Son fonctionnement est soumis aux deux conditions suivantes: 1. Cet appareil ne peut pas provoquer d’interférences et 2. Cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif. Cet émetteur radio (IC: 6545A-AF3X) a été approuvée par Industrie Canada pour l’exploitation avec l’antenne types énumérés ci-dessous avec le gain maximal admissible et requis l’impédance de l’antenne pour chaque type d’antenne indiqué. Types d’antenne non inclus dans cette liste, ayant un gain supérieur au gain maximal indiqué pour ce type, sont strictement interdits pour une utilisation avec cet appareil. Immédiatement suite à la remarque, le fabricant doit fournir une liste de tous les types d’antenne approuvé pour une utilisation avec l’émetteur, ce qui indique le gain maximal d’antenne permis (en dBi) et requis d’impédance pour chacun. • Antenne parabolique, gain: 12 dBi • Antenne parabolique, gain: 26 dBi • Antenne parabolique, gain: 29 dBi Ubiquiti Networks, Inc. 47 Appendix E: Compliance Information airFiber® X User Guide airFiber AF-5X Industry Canada FCC CAN ICES-3(B)/NMB-3(B) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This radio transmitter (FCC: SWX-AF5X) has been approved by FCC to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. • Dish antenna, gain: 23 dBi • Dish antenna, gain: 30 dBi • Dish antenna, gain: 34 dBi DFS Regulatory Regions Operation in DFS regulatory regions requires an antenna with minimum gain of 23 dBi. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter (IC: 6545A-AF5X) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. • Dish antenna, gain: 23 dBi • Dish antenna, gain: 30 dBi • Dish antenna, gain: 34 dBi CAN ICES-3(B)/NMB-3(B) Pour réduire le risque d’interférence aux autres utilisateurs, le type d’antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie. Cet appareil est conforme à la norme RSS Industrie Canada exempts de licence norme(s). Son fonctionnement est soumis aux deux conditions suivantes: 1. Cet appareil ne peut pas provoquer d’interférences et 2. Cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif. Cet émetteur radio (IC: 6545A-AF5X) a été approuvée par Industrie Canada pour l’exploitation avec l’antenne types énumérés ci-dessous avec le gain maximal admissible et requis l’impédance de l’antenne pour chaque type d’antenne indiqué. Types d’antenne non inclus dans cette liste, ayant un gain supérieur au gain maximal indiqué pour ce type, sont strictement interdits pour une utilisation avec cet appareil. Immédiatement suite à la remarque, le fabricant doit fournir une liste de tous les types d’antenne approuvé pour une utilisation avec l’émetteur, ce qui indique le gain maximal d’antenne permis (en dBi) et requis d’impédance pour chacun. • Antenne parabolique, gain: 23 dBi • Antenne parabolique, gain: 30 dBi • Antenne parabolique, gain: 34 dBi 48 Ubiquiti Networks, Inc. airFiber® X User Guide Appendix E: Compliance Information RF Exposure Warning The antennas used for this transmitter must be installed to provide a separation distance of at least 126 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter. Les antennes utilisées pour ce transmetteur doivent être installé en considérant une distance de séparation de toute personnes d’au moins 126 cm et ne doivent pas être localisé ou utilisé en conflit avec tout autre antenne ou transmetteur. Australia and New Zealand Warning: This is a Class B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it. Alert sign! follows CE marking Alert sign must be indicated if a restriction on use applied to the product and it must follow the CE marking. Ubiquiti Networks, Inc. 49 Appendix E: Compliance Information airFiber® X User Guide Frequency Ranges and Power Levels per Country/Region airFiber AF-2X The product can be operated in the countries and regions listed in the following table, within the stated frequency ranges and output power (EIRP) limits. Each country has its own power level and frequency regulations. To ensure the product operates under the necessary regulatory compliance rules, the country where the device will be used must be selected during installation. The frequency settings and output power (EIRP) limits will be tuned according to the regulations of the selected country/region: 50 Country/Region Frequency Range (Band Edges in MHz) Max. EIRP (dBm) Argentina 2400-2483 36 Australia 2400-2483 36 Bahrain 2400-2483 36 Brazil 2400-2483 36 Canada 2400-2483 36* Chile 2400-2483 36 China 2400-2483 36 Colombia 2400-2483 36 Ecuador 2400-2483 36 Ghana 2400-2483 36 Guam 2400-2483 36* Hong Kong 2400-2483 36 Indonesia 2400-2483 36 India 2400-2483 36 Kenya 2400-2483 36 Korea Republic 2400-2483 36 Kyrgyzstan 2400-2483 Not applicable Malaysia 2400-2483 36 Mexico 2400-2483 36 New Zealand 2400-2483 36 Nigeria 2400-2483 36 Peru 2400-2483 36 Philippines 2400-2483 36 Puerto Rico (U.S. territory) 2400-2483 36* Singapore 2400-2483 36 South Africa 2400-2483 36 Taiwan 2400-2483 36 Tajikistan 2400-2483 Not applicable Thailand 2400-2483 20 Turkmenistan 2400-2483 Not applicable Uganda 2400-2483 Not applicable United States 2400-2483 36* Uzbekistan 2400-2483 Not applicable Venezuela 2400-2483 36 Ubiquiti Networks, Inc. airFiber® X User Guide Appendix E: Compliance Information Country/Region Frequency Range (Band Edges in MHz) Max. EIRP (dBm) Virgin Islands (U.S. territory) 2400-2483 36* Vietnam 2400-2483 36 * A higher EIRP is possible based on FCC Part 15 requirements of reduction of conducted power by 1 dBm per 3 dBi increase of antenna gain beyond 6 dBi. Ubiquiti Networks, Inc. 51 Appendix E: Compliance Information airFiber® X User Guide airFiber AF-3X The product can be operated in the countries and regions listed in the following table, within the stated frequency ranges and output power (EIRP) limits. Each country has its own power level and frequency regulations. To ensure the product operates under the necessary regulatory compliance rules, the country where the device will be used must be selected during installation. The frequency settings and output power (EIRP) limits will be tuned according to the regulations of the selected country/region: 52 Country/Region Frequency Range (Band Edges in MHz) Max. EIRP (dBm) Austria 3410-3900 66 Belgium 3410-3900 66 Bulgaria 3410-3900 66 Canada 3450-3650 3650-3700 57 44 Croatia 3410-3900 66 Cyprus 3410-3900 66 Czech Republic 3410-3900 66 Denmark 3410-3900 66 Estonia 3410-3900 66 Finland 3410-3900 66 France 3410-3900 66 Germany 3410-3900 66 Greece 3410-3900 66 Guam (U.S. territory) 3650-3700 44 Hungary 3410-3900 66 Ireland 3410-3900 66 Italy 3410-3900 66 Latvia 3410-3900 66 Lithuania 3410-3900 66 Malta 3410-3900 66 Netherlands 3410-3900 66 Poland 3410-3900 66 Portugal 3410-3900 66 Puerto Rico (U.S. territory) 3650-3700 44 Romania 3410-3900 66 Slovakia 3410-3900 66 Spain 3410-3900 66 Sweden 3410-3900 66 United Kingdom 3410-3900 66 United States 3650-3700 44 Virgin Islands (U.S. territory) 3650-3700 44 Ubiquiti Networks, Inc. airFiber® X User Guide Appendix E: Compliance Information airFiber AF-5X The product can be operated in the countries and regions listed in the following table, within the stated frequency ranges and output power (EIRP) limits. Each country has its own power level and frequency regulations. To ensure the product operates under the necessary regulatory compliance rules, the country where the device will be used must be selected during installation. The frequency settings and output power (EIRP) limits will be tuned according to the regulations of the selected country/region: 5.1 GHz 5.2 GHz Country/Region Frequency Range (Band Edges in MHz) Max. EIRP (dBm) Argentina 5150-5250 49 Frequency Range (Band Edges in MHz) 5.4 GHz Max. EIRP (dBm) 5.8 GHz Frequency Range (Band Edges in MHz) Max. EIRP (dBm) Frequency Range (Band Edges in MHz) Max. EIRP (dBm) 5470-5725 30 5725-5850 36 5470-5600, 5650-5725 30 5725-5855 36 Bahrain 5735-5835 20 Barbados 5725-5850 36 Belize 5735-5835 30 Bolivia 5735-5835 30 5725-5850 53 5735-5835 20 5725-5850 60 5735-5835 20 5735-5835 30 5735-5835 30 5735-5835 30 5725-5795, 5815-5850 36 5735-5835 30 5735-5835 30 5735-5835 30 Australia Brazil 5470-5725 30 Brunei Darussalam Canada 5250-5350 30 Chile 5250-5350 30 5470-5600, 5650-5725 30 China Colombia 5250-5350 30 Costa Rica Denmark 5470-5725 30 Dominican Republic Ecuador 5150-5250 49 5250-5350 30 El Salvador Finland 5470-5725 30 5725-5795, 5815-5850 36 Germany 5470-5725 30 5755-5875 36 Greece 5470-5725 30 5725-5795 36 Grenada 5470-5725 30 5725-5850 36 5735-5835 30 Guatemala Honduras 5470-5725 30 5725-5850 36 5470-5725 30 5725-5850 36 5470-5725 30 5725-5875 36 India 5825-5875 36 Iraq 5735-5835 36 5725-5875 33 5725-5850 36 5735-5835 30 Hong Kong 5250-5350 30 Iceland Ireland 5470-5725 30 Italy 5470-5725 30 Jamaica 5470-5725 30 Kenya Ubiquiti Networks, Inc. 5250-5350 30 53 Appendix E: Compliance Information airFiber® X User Guide 5.1 GHz Country/Region Frequency Range (Band Edges in MHz) 5.2 GHz Max. EIRP (dBm) Frequency Range (Band Edges in MHz) 5.4 GHz Max. EIRP (dBm) Korea Republic 5.8 GHz Frequency Range (Band Edges in MHz) Max. EIRP (dBm) Frequency Range (Band Edges in MHz) Max. EIRP (dBm) 5490-5710 30 5735-5815 30 5735-5835 30 5725-5795, 5815-5875 36 5725-5850 36 Lebanon Liechtenstein 5470-5725 30 Macau Malaysia 5735-5835 30 Mexico 5150-5250 49 5250-5350 30 5735-5835 30 Morocco 5735-5835 20 Nepal 5735-5835 30 New Zealand 5470-5725 30 5725-5850 53 Norway 5470-5725 30 5725-5795, 5815-5850 53 Oman 5470-5725 30 5725-5850 36 Pakistan 5735-5835 30 Panama 5735-5835 30 Papua New Guinea 5735-5835 30 Peru 5150-5250 49 5250-5350 30 5470-5725 30 5725-5850 36 Philippines 5150-5250 49 5250-5350 30 5470-5725 30 5725-5850 36 5470-5725 30 5725-5875 36 5470-5600, 5650-5725 30 5725-5850 60 5735-5835 30 5650-5950 53 5735-5835 30 Portugal Puerto Rico (U.S. territory) 5250-5350 30 Qatar Russia 5150-5350 43 5470-5650 23 Singapore South Africa 5470-5725 30 5725-5850 60 Spain 5470-5725 30 5725-5795, 5815-5855 36 Switzerland 5470-5725 30 5725-5795, 5815-5855 36 Taiwan 5250-5350 30 5490-5710 30 5735-5815 30 Thailand 5250-5350 30 5470-5725 30 5725-5850 36 Trinidad And Tobago 5470-5725 30 5725-5850 36 United Kingdom 5470-5725 30 5725-5790, 5815-5850 36 5470-5600, 5650-5725 30 5725-5850 60 Uruguay 5470-5725 30 5725-5850 36 Uzbekistan 5470-5725 30 5725-5850 36 5735-5835 30 United States Venezuela 54 5150-5250 5150-5250 49 49 5250-5350 5250-5350 30 30 Ubiquiti Networks, Inc. airFiber® X User Guide Appendix E: Compliance Information The following table lists the maximum transmit output power (EIRP) for the 5.1 GHz band. 5.1 GHz Band Channel Bandwidth 10 MHz 20 MHz 30 MHz 40 MHz 50 MHz Ubiquiti Networks, Inc. Frequency Range (Band Edges in MHz) Maximum Transmit Output Power (EIRP) in dBm 5155-5175 39 5166-5186 44 5177-5250 49 5156-5180 37 5161-5185 39 5166-5209 44 5190-5250 49 5155-5192 37 5163-5202 39 5173-5211 44 5182-5250 49 5155-5204 37 5165-5219 39 5180-5228 44 5189-5250 49 5155-5214 37 5165-5233 39 5184-5242 44 5193-5250 49 55 Appendix E: Compliance Information RoHS/WEEE Compliance Statement English European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/ or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product. Deutsch Die Europäische Richtlinie 2002/96/EC verlangt, dass technische Ausrüstung, die direkt am Gerät und/oder an der Verpackung mit diesem Symbol versehen ist , nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf. Das Symbol weist darauf hin, dass das Produkt von regulärem Haushaltmüll getrennt entsorgt werden sollte. Es liegt in Ihrer Verantwortung, dieses Gerät und andere elektrische und elektronische Geräte über die dafür zuständigen und von der Regierung oder örtlichen Behörden dazu bestimmten Sammelstellen zu entsorgen. Ordnungsgemäßes Entsorgen und Recyceln trägt dazu bei, potentielle negative Folgen für Umwelt und die menschliche Gesundheit zu vermeiden. Wenn Sie weitere Informationen zur Entsorgung Ihrer Altgeräte benötigen, wenden Sie sich bitte an die örtlichen Behörden oder städtischen Entsorgungsdienste oder an den Händler, bei dem Sie das Produkt erworben haben. 56 airFiber® X User Guide Español La Directiva 2002/96/CE de la UE exige que los equipos que lleven este símbolo en el propio aparato y/o en su embalaje no deben eliminarse junto con otros residuos urbanos no seleccionados. El símbolo indica que el producto en cuestión debe separarse de los residuos domésticos convencionales con vistas a su eliminación. Es responsabilidad suya desechar este y cualesquiera otros aparatos eléctricos y electrónicos a través de los puntos de recogida que ponen a su disposición el gobierno y las autoridades locales. Al desechar y reciclar correctamente estos aparatos estará contribuyendo a evitar posibles consecuencias negativas para el medio ambiente y la salud de las personas. Si desea obtener información más detallada sobre la eliminación segura de su aparato usado, consulte a las autoridades locales, al servicio de recogida y eliminación de residuos de su zona o pregunte en la tienda donde adquirió el producto. Français La directive européenne 2002/96/CE exige que l’équipement sur lequel est apposé ce symbole sur le produit et/ou son emballage ne soit pas jeté avec les autres ordures ménagères. Ce symbole indique que le produit doit être éliminé dans un circuit distinct de celui pour les déchets des ménages. Il est de votre responsabilité de jeter ce matériel ainsi que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales. L’élimination et le recyclage en bonne et due forme ont pour but de lutter contre l’impact néfaste potentiel de ce type de produits sur l’environnement et la santé publique. Pour plus d’informations sur le mode d’élimination de votre ancien équipement, veuillez prendre contact avec les pouvoirs publics locaux, le service de traitement des déchets, ou l’endroit où vous avez acheté le produit. Italiano La direttiva europea 2002/96/EC richiede che le apparecchiature contrassegnate con questo simbolo sul prodotto e/o sull’imballaggio non siano smaltite insieme ai rifiuti urbani non differenziati. Il simbolo indica che questo prodotto non deve essere smaltito insieme ai normali rifiuti domestici. È responsabilità del proprietario smaltire sia questi prodotti sia le altre apparecchiature elettriche ed elettroniche mediante le specifiche strutture di raccolta indicate dal governo o dagli enti pubblici locali. Il corretto smaltimento ed il riciclaggio aiuteranno a prevenire conseguenze potenzialmente negative per l’ambiente e per la salute dell’essere umano. Per ricevere informazioni più dettagliate circa lo smaltimento delle vecchie apparecchiature in Vostro possesso, Vi invitiamo a contattare gli enti pubblici di competenza, il servizio di smaltimento rifiuti o il negozio nel quale avete acquistato il prodotto. Ubiquiti Networks, Inc. airFiber® X User Guide Appendix F: Declaration of Conformity Česky [Czech] UBIQUITI NETWORKS tímto prohlašuje, že toto UBIQUITI NETWORKS zařízení, je ve shod se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES. Dansk [Danish] Hermed, UBIQUITI NETWORKS, erklærer at denne UBIQUITI NETWORKS enhed, er i overensstemmelse med de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. Nederlands [Dutch] Hierbij verklaart UBIQUITI NETWORKS, dat deze UBIQUITI NETWORKS apparaat, in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EC. English Hereby, UBIQUITI NETWORKS, declares that this UBIQUITI NETWORKS device, is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Eesti [Estonian] Käesolevaga UBIQUITI NETWORKS kinnitab, et antud UBIQUITI NETWORKS seade, on vastavus olulistele nõuetele ja teistele asjakohastele sätetele direktiivi 1999/5/EÜ. Suomi [Finnish] Täten UBIQUITI NETWORKS vakuuttaa, että tämä UBIQUITI NETWORKS laite, on yhdenmukainen olennaisten vaatimusten ja muiden sitä koskevien direktiivin 1999/5/EY. Français [French] Par la présente UBIQUITI NETWORKS déclare que l’appareil UBIQUITI NETWORKS, est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Deutsch [German] Hiermit erklärt UBIQUITI NETWORKS, dass sich dieses UBIQUITI NETWORKS Gerät, in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet. Ελληνική [Greek] Δια του παρόντος, UBIQUITI NETWORKS, δηλώνει ότι αυτή η συσκευή UBIQUITI NETWORKS, είναι σε συμμόρφωση με τις βασικές απαιτήσεις και τις λοιπές σχετικές διατάξεις της οδηγίας 1995/5/ΕΚ. Magyar [Hungarian] Ezennel UBIQUITI NETWORKS kijelenti, hogy ez a UBIQUITI NETWORKS készülék megfelel az alapvető követelményeknek és más vonatkozó 1999/5/EK irányelv rendelkezéseit. Íslenska [Icelandic] Hér, UBIQUITI NETWORKS, því yfir að þetta UBIQUITI NETWORKS tæki er í samræmi við grunnkröfur og önnur viðeigandi ákvæði tilskipun 1999/5/EC. Italiano [Italian] Con la presente, UBIQUITI NETWORKS, dichiara che questo dispositivo UBIQUITI NETWORKS, è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti della direttiva 1999/5/CE. Latviski [Latvian] Ar šo, UBIQUITI NETWORKS, deklarē, ka UBIQUITI NETWORKS ierīce, ir saskaņā ar būtiskajām prasībām un citiem attiecīgiem noteikumiem Direktīvā 1999/5/EK. Lietuviškai [Lithuanian] UBIQUITI NETWORKS deklaruoja, kad šis UBIQUITI NETWORKS įrenginys atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Malti [Maltese] Hawnhekk, UBIQUITI NETWORKS, tiddikjara li dan il-mezz UBIQUITI NETWORKS huwa konformi mar-rekwiżiti essenzjali u dispożizzjonijiet rilevanti oħrajn ta ‘Direttiva 1999/5/EC. Norsk [Norwegian] Herved UBIQUITI NETWORKS, erklærer at denne UBIQUITI NETWORKS enheten, er i samsvar med de grunnleggende kravene og andre relevante bestemmelser i direktiv 1999/5/EF. Slovensky [Slovak] Týmto UBIQUITI NETWORKS, prehlasuje, že toto UBIQUITI NETWORKS zariadenie, je v súlade so základnými požiadavkami a ďalšími relevantnými ustanoveniami smernice 1999/5/ES. Svenska [Swedish] Härmed UBIQUITI NETWORKS, intygar att denna UBIQUITI NETWORKS enhet är i överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. Ubiquiti Networks, Inc. Appendix F: Declaration of Conformity Español [Spanish] Por medio de la presente UBIQUITI NETWORKS declara que este dispositivo UBIQUITI NETWORKS, cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Polski [Polish] Niniejszym, Ubiquiti Networks, oświadcza, że urządzenie UBIQUITI NETWORKS, jest zgodny z zasadniczymi wymaganiami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999/5/EC. Português [Portuguese] UBIQUITI NETWORKS declara que este dispositivo UBIQUITI NETWORKS, está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. Română [Romanian] Prin prezenta, UBIQUITI NETWORKS declară că acest dispozitiv UBIQUITI NETWORKS este în conformitate cu cerințele esențiale și alte prevederi relevante ale Directivei 1999/5/CE. 57 Appendix G: Contact Information airFiber® X User Guide Appendix G: Contact Information Ubiquiti Networks Support Ubiquiti Support Engineers are located around the world and are dedicated to helping customers resolve software, hardware compatibility, or field issues as quickly as possible. We strive to respond to support inquiries within a 24-hour period. Ubiquiti Networks, Inc. 2580 Orchard Parkway San Jose, CA 95131 www.ubnt.com Online Resources Support: support.ubnt.com Community: community.ubnt.com Downloads: downloads.ubnt.com AI080615 58 Ubiquiti Networks, Inc. www.ubnt.com ©2015 Ubiquiti Networks, Inc. All rights reserved. Ubiquiti, Ubiquiti Networks, the Ubiquiti U logo, the Ubiquiti beam logo, airFiber, airOS, RocketDish, TOUGHCable, and xRT are trademarks or registered trademarks of Ubiquiti Networks, Inc. in the United States and in other countries. All other trademarks are the property of their respective owners.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : A Imaoka Create Date : 2015:08:13 13:25:48-04:00 Modify Date : 2015:08:13 13:26:38-04:00 Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2015:08:13 13:26:38-04:00 Creator Tool : Adobe InDesign CC 2015 (Macintosh) Format : application/pdf Title : airFiber X User Guide Creator : A Imaoka Document ID : uuid:db73d35e-49cc-4504-9d0e-4a8aa775fa68 Instance ID : uuid:f14c346e-0ca2-408e-b236-7eb29efa99c0 Producer : Adobe PDF Library 15.0 Page Count : 38EXIF Metadata provided by EXIF.tools