United Imaging Healthcare MARS1717XU Wireless digital flat panel detector User Manual Title
Shanghai United Imaging Healthcare Co., Ltd. Wireless digital flat panel detector Title
User Manual
Wireless Digital Flat Panel Detector Mars1717XU-VSI User Manual Before operating, please read this user manual and pay attention to all safety precautions. Please ensure that this user's manual is properly maintained so that it can be accessed at any time ( reserve ). Please use it correctly on the basis of full understanding of the content. To Customers Congratulations on your purchase of the Mars1717XU-VSI Wireless Digital Flat Panel detector (hereinafter referred to as Mars1717XU) which is manufactured by iRay Technology Co.Ltd. (Hereinafter referred to as iRay). Please take time to read through this user guide in order to utilize the product effectively. We hope you enjoy the experience with iRay Mars1717XU. If you have any questions or suggestions, please feel free to contact us. Service Office Tel: +86 21 50720560 Fax: +86 21 50720561 E-mail: service@iraychina.com Location: 2F, Building 9, No.590, Ruiqing Rd, Pudong, Shanghai, Notes on usage and management of the equipment 1. Read all of the instructions in the user guide before your operation. Give particular attention to all safety precautions. 2. Only a physician or a legally certified operator should use this product. 3. The equipment should be maintained in a safe and operable condition by maintenance personnel. 4. Use only computers and image display monitors complying with IEC 60601-1 or IEC 60950-1. For details, consult our sales representative or local iRay dealer. 5. Use only the dedicated cables. Do not use any cables other than those supplied with this product. 6. The equipment should not be used in inflammable gas or corrosive gas environment. 7. Give particular attention to avoiding liquid or conductive materials invading into inside of the equipment in order to prevent the equipment from short circuit. 8. House of the equipment forbids opening by unauthorized personnel. 9. Request your sales representative or local iRay dealer to install this product。 iRay Technology Co. Ltd. Mars1717XU Wireless Digital Flat Panel Detector User Manual Caring for your environment This symbol indicates that this product is not to be disposed of with your residential or commercial waste. Recycling iRay Equipment Please do not dispose of this product with your residential or commercial waste. Improper handling of this type of waste could have a negative impact on health and on the environment. Some countries or regions, such as the European Union, have set up systems to collect and recycle electrical or electronic waste items. Contact your local authorities for information about practices established in your region. If collection systems are not available, call iRay Customer Service for assistance. Disclaimer 1. iRay shall not be liable to the purchaser of this product or third parties for any damage, losse, or injury incurred by purchaser or third parties as a result of fire, earthquake, any accident, misuse or abuse of this product. 2. iRay shall not be liable to any damage, loss, or injury arising from unauthorized modifications, repairs, or alterations to this product or failure to strictly comply with iRay’s operating and maintenance instructions. 3. iRay shall not be liable for any damage or loss arising from the use of any options or consumable products other than those dedicated as Original iRay Products by iRay Technology. 4. It is the responsibilities of the user/attending physicians for maintaining the privacy of image data and providing medical care services. iRay shall not be responsible for the legality of image processing , reading and storage nor it shall be responsible for loss of image data for any reason. 5. Information regarding specification, compositions, and appearance of this product is subject to change without prior notice.。 Copyright All rights reserved No part of this publication may be reproduced in any form or by any means without the written permission of iRay. The information contained herein is designed only for use with iRay Mars1717XU. Trademarks The iRay name and iRay logo are registered trademarks of iRay Technology Co.Ltd. iRay Technology Co. Ltd. To Customers Symbols and Conventions The following symbols and conventions are used throughout the user guide. This symbol is used to identify conditions under which improper use of the product may cause death or serious personal injury. This notice is used to identify conditions under which improper use of the product may cause minor personal injury. This notice is used to identify conditions under which improper use of the product may cause property damage. This is used to indicate a prohibited operation. This is used to indicate an action that must be performed. This is used to indicate important operations and restrictions. This is used to indicate operations for reference and complementary information. iRay Technology Co. Ltd. Mars1717XU Wireless Digital Flat Panel Detector User Manual Labels and markings on the equipment The contents of the labels and markings on iRay Mars1717XU product are indicated below: Symbol Indication This symbol is used to identify the manufactuer's series number which is after, below or adjacent to the symbol. The series number of iRay products is usually made of thirteen digits as shown below: A1A2A3A4 C1C2 M DD Y XXX Numerical Order Year Date Month Version Product Code This symbol is used to indicate the name and address of the manufacturer,.the date of manufacture can be combined in this symbol. This symbol is used to indicate consultation of the user guide for general information. Safety Signs: please refer to the user guide for safety instructions. This symbol is used to indicate detector is allowed to withstand 100 kg on the surface. Caution: please refer to the instructions in the user manual. This symbol is used to indicate the operational temperature limits. This symbol is used to indicate non-ionizing radiation. iRay Technology Co. Ltd.. To Customers This symbol is used to indicate when end-user plans to discard this product, this product should be sent to the appropriate facilities for recovery and recycling. IPX4 This symbol is used to indicate the degrees of protection provided by enclosures. This symbol is used to indicate B type applied part. Handled with care. Caution: refer to appending files for important information about safety, such as warnings and matters needing attention which is not suitable to be shown on the instrument for various reasons. Package symbol, fragile, handle with care. Package symbol, keep away from sunlight. Package symbol, keep dry. Package symbol on the the detector packing-case: storage temperature limits Package symbol, this symbol is used to indicate the humidity limits. Package symbol, keep the equipment up right. iRay Technology Co. Ltd. Mars1717XU Wireless Digital Flat Panel Detector User Manual Package symbol, do not roll the transportation package. Package symbol, this symbol is used to indicate stacking limit number. iRay Technology Co. Ltd.. Catalogue Contents CONTENTS ....................................................................................................................... 7 1. SAFETY INFORMATION ............................................................................................ 9 1.1 Safety precautions ........................................................................... 10 1.2 Notes for Using ................................................................................ 14 2. GENERAL DESCRIPTION ........................................................................................... 16 2.1 Scope ............................................................................................... 17 2.2 Characteristic ................................................................................... 17 2.3 Intended use .................................................................................... 18 2.4 Standard Product Components ....................................................... 18 2.5 Components Description.................................................................. 19 2.6 Product Specification ....................................................................... 20 3. INSTALLATION ............................................................................................................ 24 3.1 Detector Installation ......................................................................... 25 3.2 Software Installation ......................................................................... 27 3.3 Detector Configuration ..................................................................... 27 4. OPERATION ................................................................................................................. 38 4.1 Main Operation ................................................................................. 39 4.2 Block diagram ................................................................................... 39 4.3 Work Flow ......................................................................................... 40 4.4 Description of workflow ..................................................................... 40 5. REGULATORY INFORMATION .................................................................................. 42 5.1 Registrant Information....................................................................... 43 5.2 Manufacturer Information .................................................................. 43 5.3 Medical equipment safety standards ................................................ 43 5.4 References harmonized standards under Directive 93/42/EEC ....... 44 5.5 The compliance for each EMISSIONS and IMMUNITY standard or test specified by IEC60601-1-2 standard ................................................ 45 5.6 Lithium-ion Capacitor Reference Standards ..................................... 47 5.7 Product Label .................................................................................... 48 5.8 Radio Frequency Compliance Information ....................................... 48 5.9 INFORMATION TO USER. ............................................................... 49 6. SOFTWARE OPERATION INFORMATION ................................................................ 51 6.1 Default Settings ................................................................................ 52 iRay Technology Co. Ltd. Mars1717XU Wireless Digital Flat Panel Detector User Manual 7. TROUBLE SHOOTING................................................................................................. 55 8. SERVICE INFORMATION ............................................................................................ 56 8.1 Product lifetime ................................................................................ 57 8.2 Regular inspection and Maintenance ............................................... 57 8.3 Repair ............................................................................................... 58 8.4 Replacement parts support .............................................................. 58 APPENDIX ........................................................................................................................ 59 Appendix A Information of Manufactures ................................................ 60 iRay Technology Co. Ltd.. 1. Safety Information 1. Safety Information 1.1 Safety precautions ........................................................................... 10 1.2 Notes for Using ................................................................................ 14 iRay Technology Co. Ltd. Mars1717XU Wireless Digital Flat Panel Detector User Manual 1.1 Safety precautions Follow these safeguards and properly use the equipment to prevent injury and damage to any equipment/data. WARNING Installation and environment of Do not use or store the equipment near flammable chemicals such as alcohol, thinner, benzene, etc. If chemicals are spilled or evaporate, it may result in fire or electric shock through contact with electric parts inside the equipment. Also, some disinfectants are flammable. Be sure to take care when using them. use Do not connect the equipment with anything other than specified. Doing so may result in fire or electric shock. Power supply All the patients with active implantable medical devices should be kept away from the equipment. Do not operate the equipment using any type of power supply other than the one indicated on the rating label. Otherwise, it may result in fire or electric shock. Do not handle the equipment with wet hands. You may experience electric shock that could result in death or serious injury. Do not place heavy object such as medical equipment on cables and cords. Do not pull, bend, bundle, or step on them to prevent their sheath from being damaged, and do not alter them neither. Doing so may damage the cords which could result in fire or electric shock. Do not supply power to more than one piece of equipment using the same AC outlet. Doing so may result in fire or electric shock. Do not turn ON the system power when condensation has formed on the equipment. Doing so may result in fire or electric shock. Do not connect a multiple portable socket-outlet or extension cord to the system. Doing so may result in fire or electric shock. To avoid the risk of electric shock, this equipment must only be connected to power supply with protective earth. Not doing so may result in fire or electric shock. Securely plug the power cord into the AC outlet. If contact failure occurs, or if metal objects come into contact with the exposed metal prongs of the plug, fire or electric shock may result. Be sure to turn OFF the power to each piece of equipment before connecting or disconnecting the cords. Otherwise, you may get an electric shock that could result in death or serious injury. Be sure to hold the plug or connector to disconnect the cord. If you pull the cord, the core wire may be damaged, resulting in fire or electric shock. iRay Technology Co. Ltd. 10 1. Safety Information WARNING Handling Never disassemble or modify the equipment. No modification of this equipment is allowed. Parts of the Mars1717XU that are not serviced or maintained while in use with the patient. Doing so may result in fire or electric shock. Also, since the equipment incorporates parts that may cause electric shock as well as other hazardous parts, touching them may cause death or serious injury. Do not place anything on top of the equipment. The object may fall and cause an injury. Also, if metal objects such as needles or clips fall into the equipment, or if liquid is spilled, it may result in fire or electric shock. Do not hit or drop the equipment. The equipment may be damaged if it receives a strong jolt, which may result in fire or electric shock if the equipment is used without being repaired. Do not put the equipment and pointed objects together. The equipment may be damaged. If so, the equipment should be used in bucky. Have the patient take a fixed posture and do not let the patient touch parts unnecessarily. If the patient touches connectors or switches, it may result in electric shock or malfunction of the equipment. When a problem occurs Should any of the following occurs, immediately unplug the power cord of Control Box, and contact your sales representative or local iRay dealer: When there is smoke, an odd smell or abnormal sound. When liquid has been spilled into the equipment or a metal object has entered through an opening. When the equipment has been dropped and damaged. Maintenance and inspection Please turn OFF the power of the equipment and unplug the power cord of adaptor before cleaning. NEVER use alcohol, ether and other flammable cleaning agent for safety. NEVER use methanol, benzene, acid and base because they will erode the equipment. DON'T dip the equipment into the liquid. Please make sure that the equipment's surface & plugs are dry before turning ON. Otherwise, it may result in fire or electric shock. Clean the plug of the power cord periodically by unplugging it from the AC outlet and removing dust or dirt from the plug, its periphery and AC outlet with a dry cloth. If the cord is kept plugged in for a long time in a dusty, humid or sooty place, dust around the plug will attract moisture; this could cause insulation failure that may result in a fire. For safety reasons, be sure to turn OFF the power to each piece of equipment when performing inspections indicated in this manual. Otherwise, electric shocks may occur. iRay Technology Co. Ltd. 11 Mars1717XU Wireless Digital Flat Panel Detector User Manual CAUTION environment of Do not install the equipment in any of the locations listed below. Doing so may result in failure, malfunction, equipment falling, fire or injury. use Close to facilities where water is used Installation and Where it will be exposed to direct sunlight Close to the air outlet of an air-conditioner or ventilation equipment Close to heat source such as a heater Where the power supply is unstable In a dusty environment In a saline or sulfurous environment Where temperature or humidity is high Where there is freezing or condensation In areas prone to vibration On an incline or in an unstable area Take care that cables do not become tangled during use. Also, be careful not to get your feet caught by cable. Otherwise, it may cause a malfunction of the equipment or injury of the user due to tripping over the cable. Power supply Always connect the three-core power cord plug to a grounded AC power outlet. To make it easy to disconnect the plug at any time, avoid putting any obstacles near the outlet. Otherwise, it may not be possible to disconnect the plug in an emergency. Be sure to ground the equipment to an indoor grounded connector. Also, be sure to connect all the grounds for the system to a common ground. Do not use any power source other than the one provided with this equipment. Otherwise, fire or electric shock may be caused due to leakage. Handling Do not spill liquid or chemicals onto the equipment. In case the patient is injured, it is not allowed to contact with blood or other body fluids. Doing so may result in fire or electric shock. In such a situation, protect the equipment with a disposable cover as necessary. 12 Turn OFF the power and pull out the plug to each piece of equipment for safety when not used. iRay Technology Co. Ltd. 1. Safety Information CAUTION Handling Handle the equipment carefully. Do not submerge the equipment in water. The internal image sensor may be damaged if something hits against it or it is dropped. Do not place excessive weight on the equipment. Otherwise, the internal image sensor may be damaged and image collection may be malfunction.Uniform load:135 kg over the whole area of the detector surface. Local load:100 kg on an area 4 cm diameter. Be sure to use the equipment on a flat surface so it will not bend. Otherwise, the internal image sensor may be damaged. Be sure to securely hold the detector while using it in upright positions. Otherwise, the detector may flip over, resulting in injury to the user or patient as well as damage of the inner device. Keep the same load (same pressure) on the detector when acquiring the image. Or the image will be incorrect. CAUTION iRay Technology Co. Ltd. 13 Mars1717XU Wireless Digital Flat Panel Detector User Manual Do not close to fire, do not use in high temperature Do not invert positive and negative pole Do not contact with metal in case of short circuit Do not insert sharp objects into the Lithium-ion capacitor Do not beat the Lithium-ion capacitor Do not squeeze the Lithium-ion capacitor Do not use the Lithium-ion capacitor out of rules Do not change internal structure of the Lithium-ion capacitor Do not submerge the Lithium-ion capacitor in water, please keep dry in storage and do not contact with water in use Please charge the Lithium-ion capacitor with charger following IEC60601-1 Standards provide by us Do not mix the Lithium-ion capacitor with ones not provided by iRay Do not charge the Lithium-ion capacitor already damaged Adverse events may be caused by the product Due to operation or corresponding device malfunction, no valuable clinical image is acquired after exposure accomplished. Due to disturbance from a device which does not complied with IEC60601-1-2 standard , functions of the product are abnormal, which results in no valuable clinical image is acquired after exposure accomplished The product is intended to be used with registered X-ray instruments. Please refer to this manual for installment and software operation part of the product. For the rest part of operation, please refer to the operation manual of the applied X-ray instrument. Means for monitoring, evaluation, and control The product status indication is referred in “Product installation, connection” part of this manual. If the indication is not correct, please do not use. The measuring function must be re-calibrated after exchanging or re-installation of FPD. The measuring function should be calibrated every half year if the product structure is not disassembled. 1.2 Notes for Using When using the equipment, take the following precautions. Otherwise, problems may occur and the equipment may not function correctly. Before exposure 14 Be sure to check the equipment daily and confirm that it works properly. iRay Technology Co. Ltd. 1. Safety Information Sudden heating of the room in cold areas will cause condensation to form on the equipment. In this case, wait until the condensation evaporates before performing an exposure. If the equipment is used while condensation is formed on it, problems may occur in the quality of captured images. When an air-conditioner is used, be sure to raise/lower the temperature gradually so that a difference of temperature in the room and equipment does not occur, to prevent condensation. The detector should warm up for 30 minutes before exposure or updating the gain map or defect map. During exposure Do not move the power or Ethernet Cables during exposure, or it may cause image noise or artifacts, even incorrect images. Do not use the devices near the equipment generating a strong magnetic field. Otherwise, it may cause image noise, artifacts or even incorrect images. After exposure Recommend to shut down the detector’s power for storage when no use. Disinfection and Cleaning After every examination, wipe the patient contact surfaces of the detector using disinfectants such as ethanol, to prevent the risk of infection. For details on how to sterilize, consult a specialist. Do not spray the detector directly with disinfectants or detergents. Wipe it with a cloth slightly damped with a neutral detergent. Do not use solvents such as alcohol, thinner, benzene, acid and base. Doing so may damage the surface of the equipment. It's recommended to use a waterproof non-woven cover as the isolated layer between detector and the blooding patient. iRay Technology Co. Ltd. 15 2. General Description 2. General Description 2.1 Scope ............................................................................................... 17 2.2 Characteristic ................................................................................... 17 2.3 Intended use..................................................................................... 18 2.4 Standard Product Components ........................................................ 18 2.5 Components Description .................................................................. 19 2.5.1 Detector .................................................................................. 19 2.5.2 Power Supply ......................................................................... 20 2.6 Product Specification ....................................................................... 20 2.6.1 Detector .................................................................................. 20 2.6.1.1 Basic ................................................................................... 20 2.6.1.2 MTF .................................................................................... 21 2.6.1.3 DQE .................................................................................... 21 2.6.2 Power supply ......................................................................... 21 2.6.3 AP Router (Optional) ............................................................. 22 2.6.4 Wireless Communication ...................................................... 22 2.6.5 Recommended Appliance Condition ..................................... 23 2.6.6 Use Environment ................................................................... 23 16 iRay Technology Co. Ltd. Mars1717XU Wireless Digital Flat Panel Detector User Manual Mars1717XU is a cassette-size wireless X-ray flat panel detector based on amorphous silicon thin-film transistor technologies. It is developed to provide the highest quality of radiographic image, which contains an active matrix of 3072×3072 with 139um pixel pitch. Detectors’ scintillator is CsI(Caesium Iodide). The greatest improvement is Mars1717XU supports wireless communication between detectors and PC, and employs Lithium-ion capacitor, which makes Mars1717XU a real portable panel. 2.1 Scope This manual contains information about the iRay Mars1717XU. All operators must read and understand this manual before using equipment. All information in this manual, including the illustrations, is based on equipment prototype. If configuration of your equipment does not have any of these items, information about these items in the manual does not apply to your equipment. 2.2 Characteristic Mars □ □ □ VSI- CsI scintillator screen Product Application:XU, cassette size detector Product dimension:1717,17inch×17inch Product serials:wireless digital flat panel detector serials Wireless static Flat Panel Detector used for general radiography. 17 × 17 inch Built-in non-detachable Lithium-ion capacitor iRay Technology Co. Ltd. 17 Mars1717XU Wireless Digital Flat Panel Detector User Manual 2.3 Intended use The Mars1717XU Wireless Digital Flat Panel detector (hereinafter referred to as Mars1717XU) is compatible with digital medical X-ray radiography system for a medical institute to acquire digital X-ray imaging of patient body. The Flat Panel Detector (FPD) of Mars1717XU is one of the flat panel detector series based on amorphous silicon technology, which are used in DR system to provide clinical X-ray images. The host computer of Mars1717XU-VSI flat panel detector employs Caesium Iodide (CsI) scintillation screen, and provides WIFI data port and DC power supply. This panel is not intended for mammography or dental applications,and prohibited for pregnant women. According to the Mars1717XU intended use and the result of risk management, identifying and describing the essential performance as the following: a) To perform communication and instruction transmission between the flat plane detector and computer system through wireless router b) To perform imaging acquisition by the flat panel detector This equipment provides digital X-ray imaging for diagnosis of disease, injury, or any applicable health problem. The image is obtained as the result of X-ray passing through the human body and detected by the equipment. iRay will provide equipment and software support for integration of system. The length of\ DC Power Cable cannot exceed 3.5 m. Or the impedance of protective earth connections may exceed the safety threshold. 2.4 Standard Product Components Mars1717XU comes with power supply by both 12V DC and bulit-in Lithium-ion capacitor. Once powered on, it would build a connection with PC through Wireless connection. Item Flat Panel Detector 18 Description Mars1717XU iRay Technology Co. Ltd. 2. General Description Defect correction map CD-Rom SDK Manual 2.5 Components Description 2.5.1 DETECTOR Item Name Description DC Input Interface DC input Detector Indicator Power/Internet Connection/Status Detector indicator of detector Button Power button / Reset Switch hole Front surface film In line with biological compatibility Middle frame Supporting and fixation Back surface film In line with biological compatibility Detector Label Product information. iRay Technology Co. Ltd. 19 Mars1717XU Wireless Digital Flat Panel Detector User Manual 2.5.2 POWER SUPPLY Mars1717XU supports both DC and bulit-in Lithiu-ion capacitor power supply. The DC power supply is not in the product package, and the external power adapter is only used for customer service maintenance and production. 2.6 Product Specification 2.6.1 DETECTOR 2.6.1.1 BASIC Item Specification Model Mars1717XU-VSI Image Sensor a-Si (Amorphous Silicon) TFT Pixel Size 139 μm Pixel Matrix 3072 x 3072 Effective Area (H x V) 427 x 427 mm Greyscales 16bit Spatial Resolution 3.6 Lp/mm Preview Acquisition Time@Client (5GHz) 2.5 sec (since exposure ends) Processed Acquisition Time@Client (5GHz) 5 sec. (since exposure ends) Cycle Time Min. 8.5s Power Consumption Max. 30W (including charging) Stand-by Power Consumption Max.5W Charging Time Max. 50minutes Discharging Time Cycle time=30s, 30min, 60images Cycle time=90s, 45min, 30images 20 Exposure Preparation Time 1s Sleeping Awakening Time 2s Sleeping Endurance Time 1h Dimension (L × W × H) 460 x 460 x 15.4 mm Weight 3.9kg iRay Technology Co. Ltd. 2. General Description WIFI IEEE802.11a/b/g/n/ac (2.4G/5G) X-ray Energy 40kV to 150kV 2.6.1.2 MTF Spatial Frequency (lp/mm) MTF(CsI) 1.0 0.65 2.0 0.43 3.0 0.17 Spatial Frequency (lp/mm)@RQA5 DQE (CsI)@2.5uGy 0.65 1.0 0.45 2.0 0.30 3.0 0.20 2.6.1.3 DQE 2.6.2 POWER SUPPLY Mars1717XU supports both DC and built-in Lithium-ion capacitor power supply.. Item Specifications DC Power 12V(DC),2.5A Lithium-ion Capacitor iRay Technology Co. Ltd. 7.6V(DC),0.93A 21 Mars1717XU Wireless Digital Flat Panel Detector User Manual 2.6.3 AP ROUTER (OPTIONAL) Mars1717XU does not include a wireless AP Router. Users can choose according to their requirement, but the following specification must be matched. Item Wireless Standard Frequency Range Specifications IEEE 802.11 a/b/g/n/ac 2.400 ~ 2.4835 GHz and 5.15~5.25 GHz 5.725~5.85 GHz 802.11b : Max. 11Mbps Wireless Data Rate 802.11a/g : Max. 54Mbps 802.11n : Max. 300Mbps (MIMO 2x2) 2.6.4 WIRELESS COMMUNICATION Item Wireless Standard Description IEEE802.11a/b/g/n/ac 2.4G: 2.400 ~ 2.4835 GHz @CH1-CH13 HT20 Section @CH3-CH11 HT40 Section Frequency Range 5G: 5.15~5.25 GHz and 5.725~5.85 GHz @CH36-CH165 HT20 Section @CH38-CH163 HT40 Section 802.11b: CCK, DQPSK, DBPSK 802.11a/g: Modulation 64 QAM, 16 QAM, QPSK, BPSK 802.11n: 64 QAM, 16 QAM, QPSK, BPSK Antenna 22 2 Dual Band internal antenna iRay Technology Co. Ltd. 2. General Description 2.6.5 RECOMMENDED APPLIANCE CONDITION Item Description Operating System Windows 8 64bit CPU Intel Core i7 3.6G Memory 8G DDR3 Hard Disk 640 G LAN Card Intel Pro EXP9301CT PRO 2.6.6 USE ENVIRONMENT Operating Storage Temperature 5~35℃ -30~55℃ Temperature change <1k/min <1k/min Humidity 30%~80% RH 10%~90% RH Atmospheric Pressure 700~1060hPa 700~1060hPa <10kp/min <10kp/min (1kp=1.0197E-5Pa) (1kp=1.0197E-5Pa) Pressure Change The Mars1717XU serial detectors shall operate at an altitude specified NO more than 3000m. iRay Technology Co. Ltd. 23 3. Installation and Operation 3. Installation 3.1 Detector Installation ......................................................................... 25 3.1.1 Attach dc power...................................................................... 25 3.1.1 booting up............................................................................... 25 3.2 Software Installation ......................................................................... 27 3.3 Detector Configuration ..................................................................... 27 3.3.1 AP Mode ................................................................................. 27 3.3.1.1 External Wireless LAN Setting ............................................ 27 3.3.1.2 AP Mode Detector Configuration ........................................ 29 3.3.2 Client Mode ............................................................................ 32 3.3.2.1 Configuration of External wireless router ............................ 32 3.3.2.2 Client mode configuration of detector ................................. 36 iRay Technology Co. Ltd. 24 Mars1717XU Wireless Digital Flat Panel Detector User Manual 3.1 Detector Installation 3.1.1 ATTACH DC POWER Insert the DC power cable into the DC input port of the detector 3.1.1 BOOTING UP On the control panel, user can press power button to power on/off the detector. If detector is powered off, users can press the button for 3 seconds to power on the detector when a Lithium-ion capacity is inserted and the Lithium-ion capacitor is no less than 20%, or direct current power is connected. If detector is powered on, users can press the button for 5 seconds to shut down the detector. On the other hand, it can also be used as internal control IC reset button when button is active for 8s. After booting up the detector, user can check the status LED indicator of detector. 25 iRay Technology Co. Ltd. Mars1717XU Wireless Digital Flat Panel Detector User Manual The power indicator C shows as following: Power Indicator Operating Battery Capacity DC Input OFF Power OFF/Sleep Orange On Power ON/Wake up ≤30% NO Green On Power ON/Wake up ≧30% NO Orange Slow Blinking Power ON ≤30% YES Green Slow Blinking Power ON ≧30% YES OFF after Orange ON with 1sec Power OFF ≤20% NO OFF after Green ON with 1sec Power OFF ≧20% NO Lighting Status Link indicator D shows as following: LINK Indicator Lighting Status Description OFF Shut down/Wired&Wireless connection not ready Blue ON Client mode, Wireless connection is ready Blue Blinking AP mode, Wireless AP is ready Green ON Wired Connection is ready Green Blinking Or RST key(AP/Client switch) active Status indicator E shows as following: Status indicator 26 Lighting Status Description OFF Shut down/Idle Green ON Data Transmission/RST Key(Recovery) active Orange ON ERROR iRay Technology Co. Ltd. 3. Installation and Operation KEY button as following table: PWB key-B; RST key-A Key PWB key Key RST key Push Time Description ≤1.5s None action ≧1.5s - <3s Power ON or Wake up ≧3s - <7.5s Power OFF ≧7.5s Power Reset Push Time Description <3s None action ≧3s - <7.5s AP/Client mode switch ≧7.5s Recovery Factory Parameters(include AP address) 3.2 Software Installation In the case of IDetector doesn’t work, please install following VC redistribute package .NET Framework. ( IDetector should not be used for terminal hospital) 1. Install Microsoft .NET Framework 4.5 before first use, which needs to be downloaded from the Microsoft website. 2. Need to install VC redistribution package vcredist_x86_2013 (or vcredist_x64_vs2013). 3.3 Detector Configuration 3.3.1 AP MODE AP Mode is the default set mode of the product during purchasing. The default SSID is XU-SN, password is 12345678, and IP address is 192.168.8.8. The detector will directly connect to wireless LAN when power on. A user should accomplish wireless client configuration of AP mode as following steps: 3.3.1.1 EXTERNAL WIRELESS LAN SETTING iRay Technology Co. Ltd. 27 Mars1717XU Wireless Digital Flat Panel Detector User Manual Open the wireless signal list Select SSID belong to the detector and input the password Open wireless network status 28 iRay Technology Co. Ltd. 3. Installation and Operation open IPV4 setting IP setting IP address: 192.168.8.188 Network mask setting Subnet mask: 255.255.255.0 Open SDK, select corresponding product and start connection by clicking “connect” 3.3.1.2 AP MODE DETECTOR CONFIGURATION Connect the detector and Indetector in default AP mode iRay Technology Co. Ltd. 29 Mars1717XU Wireless Digital Flat Panel Detector User Manual Click “Detector” button of IDetector software Click “wifi” button Select “AP mode” 1. Click “Read Config” button to read the default setting; 2. Change SSID and password setting to make sure SSID not to conflict with other existing devices’ SSID; 30 iRay Technology Co. Ltd. 3. Installation and Operation Change the channel frequency settings. and Click “Chanel” to select a clean wireless frequency and channel. Click “write Config” iRay Technology Co. Ltd. 31 Mars1717XU Wireless Digital Flat Panel Detector User Manual Unplug wire cable until the status of the panel change to Ready from Busy. Since the default SSID and password have been changed, a revised AP SSID will be shown when the detector is power on next time. 3.3.2 CLIENT MODE The user needs to complete the wireless client mode configuration according to the following operation. When different detectors are used, it is strictly forbidden to use the same SSID name for connection. 3.3.2.1 CONFIGURATION OF EXTERNAL WIRELESS ROUTER Connect one end of Gigabit Ethernet Cable to PC, Connect another end to LAN port of External wireless router Open network management interface 32 iRay Technology Co. Ltd. 3. Installation and Operation Open Local configuration network Open IPV4 setting IPSetting Network mask setting iRay Technology Co. Ltd. Select “Obtain an IP address automatically” 33 Mars1717XU Wireless Digital Flat Panel Detector User Manual Open browser 192.168.1.1 and type Log into external wireless router to set configuration through the interface. Wireless setup SSID: NETGEAR_BIG_24 (For example, set up a wifi named Mars2.4G) Configure 2.4GHz wireless network Security: WPA2-PSK Password: 12345678 Channel: [Please check the current Wi-Fi environment, and choose a relatively clean channel] Configure network 5GHz wireless SSID: NETGEAR_BIG_50 (For example, set up a wifi named Mars5G) Security: WPA2-PSK Password: 12345678 34 iRay Technology Co. Ltd. 3. Installation and Operation Channel: [Please check the current Wi-Fi environment, and choose a relatively clean channel] LAN Setup IP address: 192.168.100.1 Configure LAN IP address Subnet Mask: 255.255.255.0 External Wireless AP Reboot Apply above settings and reboot your wireless router. Recover Local Network IPv4 setting of PC wired Ethernet interface IP setting IP address: 192.168.100.188 Network mask setting Subnet mask: 255.255.255.0 iRay Technology Co. Ltd. 35 Mars1717XU Wireless Digital Flat Panel Detector User Manual 3.3.2.2 CLIENT MODE CONFIGURATION OF DETECTOR Connect to Idetector through wireless network card under AP mode of the detector Click “Detector” button of IDetector; Click “wifi” button and “Read Config” button; Select “Client mode”; Change the default wireless router: SSID: IRAY-China Key: 1234-qwer to current wireless router (for example: set up a wifi named Mars5G) SSID: NETGEAR_BIG_50 Password: 12345678 Click “write Config ” 36 iRay Technology Co. Ltd. 3. Installation and Operation Reconnect IDetector and the flat panel detector Enter acquisition interface to set up connection iRay Technology Co. Ltd. 37 4. Operation 4. Operation 4.1 Main Operation .................................................................................. 39 4.2 Block diagram.................................................................................... 39 4.3 Work Flow ......................................................................................... 40 4.4 Description of workflow ..................................................................... 40 iRay Technology Co. Ltd. 38 Mars1717XU Wireless Digital Flat Panel Detector User Manual Mars1717XU provides SDK for users to integrate detector into their DR system. Additionally, it also provides applications for demonstration, iDetector. User can use iDetector to control detector without DR system. 4.1 Main Operation To Acquire X-ray image is the main operation of Mars1717XU. Most importantly, detector should build synchronization with X-ray generator.Mars1717XU is born with PREP_ACQ2 Mode to acquire X-ray image. 4.2 Block diagram Software mode is the basic way to acquire X-ray image. Please see figure below for general feature Panel B PC Wireless AP Panel A Router Hand Switch Workstation is a host PC device installed with IDetector or SDK. In RREP_ACQ2 Mode, the workstation communicates with GCU through SDK (double panel mode) or the flat panel detector to control X-ray imaging time of X-ray generator. 39 iRay Technology Co. Ltd. Mars1717XU Wireless Digital Flat Panel Detector User Manual 4.3 Work Flow Push down “hand switch I” button GCU informs high voltage exposure preparation, meanwhile informs the Panel to prepare for exposure through AP The panel starts an action of “exposure preparation”; after the action finishes, the panel informs GCU to make exposure enable through AP. Enable exposure, open the window, start “hand switch II” to expose End the exposure window, upload the acquired image SDK uploads pre-viewed image SDK uploads full image The system go to sleep 4.4 Description of workflow 1. Workstation PC receives “Awaken hand switch I prep ” request, sends command “Awaken” to the detector; the detector starts internal clear after receiving “Awaken” command sent from the workstation; 2. Meanwhile the workstation informs GCU (I/O Box) to control high voltage generator to start anode rotation; 40 iRay Technology Co. Ltd. 4. Operation 3. Workstation PC receives “Hand switch II exposure” request, confirms whether GCU anode rotation has ended and whether the detector has completed awaken preparation; 4. If the preparation is completed, the workstation PC asks GCU to send “Hand switch II exposure” request to high voltage generator; 5. Send “Exposure” request to the flat panel detector if preparation of the high voltage generator is confirmed to be completed; 6. The detector sends “Exposure” information to GCU, and then corresponding information will be shown in IDetector information bar, and the user is noticed that the detector is ready to receive X-ray; 7. GCU receives “Exposure” to start generating X-ray, and the X-ray generator starts to release X-ray; 8. After the X-ray generator finishes X-ray shooting, GCU send “End exposure” request to the detector; 9. The detector receives “End exposure” request from GCU and then perform “Acquire” action; 10. The detector completes image acquisition and begins to send data to the workstation; 11. Workstation receives all image data from the detector (including preview image and full image). Typical Cycle Analysis Hand Switch II II Rotating Anode Filament iRay Technology Co. Ltd. 41 5. Regulatory Information 5. Regulatory Information 5.1 Registrant Information ....................................................................... 43 5.2 Manufacturer Information .................................................................. 43 5.3 Medical equipment safety standards ................................................ 43 5.4 References harmonized standards under Directive 93/42/EEC ....... 44 5.5 Guidance and manufacture’s declaration for EMC ........................... 45 5.6 Lithium-ion Capacitor Reference Standards ..................................... 47 5.7 Product Label .................................................................................... 48 5.7.1 Detector Host Label ............................................................... 48 5.7.2 Host Housing Label ................................................................ 48 5.8 Radio Frequency Compliance Information ........................................ 48 5.8.1 SRRC Compliance ................................................................. 48 iRay Technology Co. Ltd. 42 Mars1717XU Wireless Digital Flat Panel Detector User Manual 5.1 Registrant Information Registrant: iRay Technology Co., Ltd . Address: Room 202, Building 9, No.590, Ruiqing Rd, East area of Zhangjiang Hi-tech industrial district, Pudong, Shanghai, PRC, 201201 Contact: +86-21-50720560 After-sales Service Office: iRay Technology Co., Ltd . Address of After-sales Service Office: Building 45, No.1000, Jinhai Rd, Pudong New Area, Shanghai, PRC, 201206 Contact of After-sales Service Office: +86-21-50720560 5.2 Manufacturer Information Manufacturer: iRay Technology Co., Ltd . Address: Room 202, Building 9, No.590, Ruiqing Rd, East area of Zhangjiang Hi-tech industrial district, Pudong, Shanghai, PRC, 201201 Production Address: Room 202, Building 9, No.590, Ruiqing Rd, East area of Zhangjiang Hi-tech industrial district, Pudong, Shanghai, PRC, 201201 Contact: +86-21-50720560 Production Licence Number: Shanghai Food and Drug Machinery Safety Production Permission No. 20121946 5.3 Medical equipment safety standards Medical equipment classification Type of protection against electrical Class I Equipment (using Mars1717XU shock medical approved adaptor supply) Internally powered Equipment (using Mars1717XU Lithium-ion capacitor power supply) Degree of protection against electrical B-type Applied Parts shock Degree of protection against ingress of IPX4(Mars1717XU) water Mode of operation Continuous operation There are two modes for power supply and signal transmission of the product: internal 43 iRay Technology Co. Ltd. Mars1717XU Wireless Digital Flat Panel Detector User Manual Lithium-ion capacitor power supply and adaptor supply, wireless transmission. Any one of power supply modes may combine with wireless transmission. Not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide. 5.4 References harmonized standards under Directive 93/42/EEC Applicable safety standards of Mars1717XU series digital wireless X-ray imaging device cover the product host and other accessories. MDD (93/42/EEC) Medical Device Directive EN ISO 13485:2012/EN ISO Medical devices --- Quality management systems --- 13485:2012/AC:2012 Requirements for regulatory purposes EN ISO14971: 2012 IEC 60601-1:2005+ Amendment 1:2012/EN 60601-1:2006+ Amendment 1:2013 Medical device – Application of risk management to medical devices Medical electrical equipment -- Part 1: General requirements 2:2015 basic safety equipment – and essential performance Medical IEC 60601-1-2:2014/EN60601-1- for electrical Part 1-2: General requirements for basic safety and essential performance – Collateral standard: Electromagnetic disturbances – Requirements and tests Medical electrical equipment -- Part 2-54: Particular IEC 60601-2-54:2015/EN requirements for the basic safety and essential 60601-2-54:2015 performance of X-ray equipment for radiography and radioscopy Secondary cells and batteries containing alkaline or other non-acid electrolytes – IEC 62133:2012 Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications EN 62220-1:2004 44 Medical electrical equipment - Characteristics of iRay Technology Co. Ltd. 5. Regulatory Information digital X-ray imaging devices - Part 1: Determination of the detective quantum efficiency Medical EN 62304:2006/AC:2008 device software Software life-cycle processes Medical devices - Application of usability engineering to medical devices EN 62366:2008 5.5 The compliance for each EMISSIONS and IMMUNITY standard or test specified by IEC60601-1-2 standard EMI Compliance Table Emission Phenomenon RF emissions Compliance CISPR 11 Group 1, Class B Harmonic distortion Voltage fluctuations and flicker IEC 61000-3-2 Class A IEC 61000-3-3 Compliance Electromagnetic environment Professional healthcare facility environment Professional healthcare facility environment Professional healthcare facility environment EMS Compliance Table Enclosure Port Phenomenon Electrostatic Discharge Basic EMC standard IEC 61000-4-2 Immunity test levels Professional healthcare facility environment ±8 kV contact ±2kV, ±4kV, ±8kV, ±15kV air 3V/m Radiated RF EM field IEC 61000-4-3 80MHz-2.7GHz 80% AM at 1kHz Proximity fields from RF wireless communications equipment IEC 61000-4-3 Refer to table “Proximity fields from RF wireless communications equipment” Rated power frequency magnetic IEC 61000-4-8 30A/m iRay Technology Co. Ltd. 45 Mars1717XU Wireless Digital Flat Panel Detector User Manual fields 50Hz or 60Hz Proximity fields from RF wireless communications equipment Test frequency Band Immunity test levels (MHz) (MHz) Professional healthcare facility environment 385 380-390 Pulse modulation 18Hz, 27V/m 450 430-470 FM, ±5kHz deviation, 1kHz sine, 28V/m 704-787 Pulse modulation 217Hz, 9V/m 800-960 Pulse modulation 18Hz, 28V/m 1700-1990 Pulse modulation 217Hz, 28V/m 2400-2570 Pulse modulation 217Hz, 28V/m 5100-5800 Pulse modulation 217Hz, 9V/m 710 745 780 810 870 930 1720 1845 1970 2450 5240 5500 5785 Input d.c. power Port Phenomenon Electrical fast transients/burst Conducted disturbances induced by RF fields 46 Basic EMC standard IEC 61000-4-4 Immunity test levels Professional healthcare facility environment ±2 kV 100kHz repetition frequency 3V, 0.15MHz-80MHz IEC 61000-4-6 6V in ISM bands between 0.15MHz and 80MHz 80%AM at 1kHz Cables information below is provided for EMC reference. iRay Technology Co. Ltd. 5. Regulatory Information Cable Recommended Shielded or cable length Unshielded 3m 3.5m AC Power Cable DC Power Cable Number Cable classification Unshielded 1 Set AC Power Unshielded 1 pcs Signal Important information regarding Electro Magnetic Compatibility (EMC) Mars1717XU require special precautions regarding EMC and needs to be installed only by iRay or authorized personnel and put into service according to EMC information provided in the user manual. Mars1717XU in use may be susceptible to electromagnetic interference from portable and mobile RF communications such as mobile (cellular) telephones. Electromagnetic interference may result in incorrect operation of the system and create a potentially unsafe situation. Mars1717XU conforms to this EN60601-1-2:2015 standard for both immunity and emissions. Nevertheless, special precautions need to be observed: The use of accessories, transmitters and cables other than those specified by this User Manual, with the exception of accessories and cables sold by iRay of Mars1717XU as replacement parts for internal components, may result in increased EMISSIONS or decreased IMMUNITY of Mars1717XU. 5.6 Lithium-ion Capacitor Reference Standards Standards Description IEC 62813, Ed. 1 Lithium ion capacitors for use in electric and electronic equipment - Test methods for electrical characteristics QC-T 741-2014 Ultra-capacitor for Electric Vehicles UN38.3 United Nations Recommendations on the Transport of dangerous goods Manual of tests and Criteria ST/SG/AC.10/11/Rev.5/Amend.1&Amend.2 GB31241-2014 Lithium ion cells and batteries used in portable electronic equipments - Safety requirements iRay Technology Co. Ltd. 47 Mars1717XU Wireless Digital Flat Panel Detector User Manual 5.7 Product Label 5.7.1 DETECTOR HOST LABEL 5.7.2 HOST HOUSING LABEL 5.8 Radio Frequency Compliance Information 5.8.1 SRRC COMPLIANCE This equipment has been tested and found to comply with CMIIT ID:2017AP3876 of SRRC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. 48 Operation is subject to the following tow conditions. iRay Technology Co. Ltd. 5. Regulatory Information This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measure. Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the distributor or an experienced X-ray technician for help. 5.9 INFORMATION TO USER. The users manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. In cases where the manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the information required by this section may be included in the manual in that alternative form, provided the user can reasonably be expected to have the capability to access information in that form. (A) ALL OTHER DEVICES SHALL BEAR THE FOLLOWING STATEMENT IN A CONSPICUOUS LOCATION ON THE DEVICE: THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. iRay Technology Co. Ltd. 49 Mars1717XU Wireless Digital Flat Panel Detector User Manual (B) FOR A CLASS B DIGITAL DEVICE OR PERIPHERAL, THE INSTRUCTIONS FURNISHED THE USER SHALL INCLUDE THE FOLLOWING OR SIMILAR STATEMENT, PLACED IN A PROMINENT LOCATION IN THE TEXT OF THE MANUAL: NOTE: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS B DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE IN A RESIDENTIAL INSTALLATION. THIS EQUIPMENT GENERATES, USES AND CAN RADIATE RADIO FREQUENCY ENERGY AND, IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTIONS, MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS. HOWEVER, THERE IS NO GUARANTEE THAT INTERFERENCE WILL NOT OCCUR IN A PARTICULAR INSTALLATION. IF THIS EQUIPMENT DOES CAUSE HARMFUL INTERFERENCE TO RADIO OR TELEVISION RECEPTION, WHICH CAN BE DETERMINED BY TURNING THE EQUIPMENT OFF AND ON, THE USER IS ENCOURAGED TO TRY TO CORRECT THE INTERFERENCE BY ONE OR MORE OF THE FOLLOWING MEASURES: REORIENT OR RELOCATE THE RECEIVING ANTENNA. INCREASE THE SEPARATION BETWEEN THE EQUIPMENT AND RECEIVER. CONNECT THE EQUIPMENT INTO AN OUTLET ON A CIRCUIT DIFFERENT FROM THAT TO WHICH THE RECEIVER IS CONNECTED. CONSULT THE DEALER OR AN EXPERIENCED RADIO/TV TECHNICIAN FOR HELP. This device has been tested and meets the FCC RF exposure guidelines. The maximum SAR value reported is 0.28 w/kg. 50 iRay Technology Co. Ltd. 6. Software Opeartion Information 6. Software Operation Information 6.1 Default Settings ................................................................................ 52 iRay Technology Co. Ltd. 51 Mars1717XU Wireless Digital Flat Panel Detector User Manual Please refer to Chapter 3 of this manual “IDetector use method” and description of iRayDR user manual for operation of the software. 6.1 Default Settings Default setting parameters of part of detector software are as following: [Battery] Battery_Level_1_H=100 Battery_Level_1_L=60 ; normal operation, allow exposure Battery_Level_2_H=59 Battery_Level_2_L=40 ; normal operation, low power warning, allow exposure Battery_Level_3_H=39 Battery_Level_3_L=30 ; normal operation, low power warning, forbid exposure Battery_Level_4_H=29 ; forbid use, the system needs shut down (<20% auto shut down) Battery_Level_4_L=0 [Wireless] Signal_Split_1=70 ; normal operation, allow exposure Signal_Split_2=40 ; normal operation, forbid exposure [Temperature] Temp_NormalRange_H=50 ; normal operation, allow exposure Temp_NormalRange_L=10 ; normal operation, allow exposure Temp_FatalLimit_H=60 ; not recommend use, forbid exposure Temp_FatalLimit_L=5 ; not recommend use, forbid exposure [SDK] Cfg_FpsCheck_Enable=0 Cfg_FpsCheck_Tolerance=0 Cfg_FWUpdTimeOut=1800 Cfg_OfflineInspectTimeout=10 Cfg_AllowReconnectByOnlineNotice=1 Cfg_ResetTimeout=120 Cfg_PreviewImage_Enable=1 Cfg_PushImageAtExpTimeout_Enable=1 52iRay Technology Co. Ltd. 6. Software Opeartion Information Cfg_RetransferCount=3 Cfg_ClearAcqParam_DelayTime=600 Cfg_ConnRecoverTimeout=60 Cfg_TemperatureHighThreshold=40 Cfg_AllowMismatchSN=1 Cfg_ImagePacketGapTimeout=1000 Cfg_FwAllowedDefectPoints=8000 Cfg_PostOffsetStart_DelayTime=300 Cfg_TotalAcqTimeout=30000 Cfg_PreExpImageAcqTimeout=1000 Cfg_CleanupProcessTime=2000 [FactoryParameters] Product No=45 Product No=45 Sub Product No=SubProductNo_CsI550 Serial No=VT36xxxxxxxxx Main Version=1.6.x.x Read Version=0.0.0.0 Master Build Time=17-03-02:1 Slave Build Time=00-00-00:0 MCU Build Time=00-00-00:0 CBX Build Time=00-00-00:0 Src IP=192.168.100.8 Src MAC=000FEAEF6FBE Dest Port=28000 Dest IP=192.168.100.188 Dest MAC=5CF9DD5FE30E Sync-Box IP=192.168.100.96 Auto Sleep Idle Time (minute)=0 Trigger Mode=TriggerMode_Prep iRay Technology (Shanghai) Ltd. Doc N0.: 058-201-02 Version: A4 Date:2017.08.23 53 Mars1717XU Wireless Digital Flat Panel Detector User Manual Prep CapMode=PrepCapMode_Acq2 Self CapEnable=On Integrate Time (ms)=776 Self Clear Span Time (us)=100 Sequence Interval Time (ms)=8000 Tube Ready Time=500 Set Delay Time (ms)=600 Exp Window Time (ms)=10000 Sync Exp Time (ms)=65535 VT (v)=0.87 Dyna Offset Gap Time (ms)=100 Image Channel Protocol=Ethernet_TCP 54 iRay Technology (Shanghai) Ltd. Doc N0.: 058-201-02 Version: A4 Date:2017.08.23 7. Trouble Shooting 7. Trouble Shooting This section is detailed in the Mars1717XU service manual. iRay Technology Co. Ltd. 55 Mars1717XU Wireless Digital Flat Panel Detector User Manual 8. Service Information 8.1 Product lifetime ................................................................................ 57 8.2 Regular inspection and Maintenance ............................................... 57 8.2.1 Daily inspection ...................................................................... 57 8.2.2 Monthly and annual inspection............................................... 57 8.3 Repair ............................................................................................... 58 8.4 Replacement parts support .............................................................. 58 56 iRay Technology Co. Ltd. 8. Service Information 8.1 Product lifetime The estimated product lifetime is up to 7 years under appropriate regular inspection and maintenance. (The Lithium-ion capacitor could last for 7 years) 8.2 Regular inspection and Maintenance In order to ensure the safety of patients, operating person and third parties, and to maintain the performance and reliability of the equipment, be sure to perform regular inspection at least once a year. If necessary, clean up the equipment, make adjustments, or replace consumables such as fuses, detector cable, etc. There may be cases where overhaul is recommended depending on conditions. Contact iRay service office or local iRay dealer for regular inspection or maintenance. Cause the Lithium-ion capacitor products have its own power consumption, Please make sure that Mars1717XU is fully charged before it is stored and shipment, alse it needs take a full charge each two months during storage. 8.2.1 DAILY INSPECTION Before and after using this product, following inspections should be taken: Item Operation Ensure the detector has no screw loosening or cracks. Detector Ensure there is no dust or dirt attached on connection pins of Lithium-ion capacitor Ensure there is no crack or short circuit in the Lithium-ion capacitor connection pin. Ensure the cables have no damage and no torn shell Cables Ensure connection between power cable and AC I/O socket reliable 8.2.2 MONTHLY AND ANNUAL INSPECTION Item Frequency Operation Resolution Every month/ Every year Use resolution image or body model to inspect Linearity Every month/ Every year Evaluate through checking the grey value of images Correction Every month/ Every year When X-ray generator, bulb, collimator or exposure environment changes If there is any repair, maintenance and inspection involved with opening the housing of the instrument, please make sure to contact after-sale service engineering with corresponding qualification, or please contact Shanghai iRay after-sales service department or authorized product distributors. iRay Technology Co. Ltd. 57 Mars1717XU Wireless Digital Flat Panel Detector User Manual There is a Lithium-ion capacitor in the FPD, its lifetime is 7 years, when arrived in the lifetime of the capacitor it needs to be placed. And the placement needs contact Shanghai iRay after-sales service departments or authorized product distributors. 8.3 Repair The product faults may be decreased to the minimum if the user follow this manual to do maintenance on time. However, if a problem cannot be solved even taking the measures indicated in troubleshooting, contact your sales representative or local iRay dealer for repairs. Please refer to the name label and provide the following information: Product Name: Series Number: Description of Problem: as clearly as possible 8.4 Replacement parts support Performance parts (parts required to maintain the function of the product) of this product will be stocked for 8 years after discontinuance of production, to allow for repair. 58 iRay Technology Co. Ltd. Appendix Appendix Appendix A Information of Manufactures ................................................ 60 iRay Technology Co. Ltd. 59 Mars1717XU Wireless Digital Flat Panel Detector User Manual Appendix A Information of Manufactures 60 COMPANY: iRay Technology Co.LTD. ADDRESS: Rm202, Building 7, No. 590, Ruiqing Rd, Zhangjiang East, Pudong New Area, Shanghai, China ZIP CODE: 201201 TELEPHONE: +86-21-50720560 FAX: +86-21-50720561 HOMEPAGE: WWW.IRAYCHINA.COM SERVICE: SERVICE DEPARTMENT OF IRAY SERVICE TEL +86-21-50720560 MARKET TEL +86-21-50720560 iRay Technology Co. Ltd.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 62 Language : zh-CN Tagged PDF : Yes Title : Title Author : jinlei.zheng Subject : Subject Creator : Microsoft® Word 2013 Create Date : 2018:12:12 16:52:31+08:00 Modify Date : 2018:12:12 16:52:31+08:00 Producer : Microsoft® Word 2013EXIF Metadata provided by EXIF.tools