Universal Scientific UNA-P3 3G Module User Manual PDD TG SOM RA01

Universal Scientific Industrial Co., Ltd. 3G Module PDD TG SOM RA01

User manual

           Doc. Title  UNA Plus/ UNA-Lite Function EVB User Guide Originator  Max Shu Date  2013.10.29 Version  V1.2   Product Line    UMD (MPC) Doc. NO.    CONFIDENTIAL  Low  ;Normal High   The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
  Revision Record Version Revise content  Date 1.1 Initial Release  2013.06.06                                                             The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁1
  Category 1. FCC Regulations ....................................................................................3 2. R&TTE Regulations ..............................................................................4 3. RF Exposure Information......................................................................5 4. Information of Installed Module...........................................................6 5. Illustration of Function EVB.................................................................7 6. General Mode.........................................................................................9 6-1 Setting of Jumpers & Switches .............................................................9 7. Settings for Download /Update Mode.................................................14 8. Advance Mode......................................................................................15 8-1 Module on/off Control...........................................................................15 8-2 Voltage Settings....................................................................................15 8-3 Use External Power Supplier...............................................................16 8-4 Current Measurement...........................................................................17 8-5 Settings for Slide-Style Switch (J42)...................................................17 8-6 PCM Signal ............................................................................................18 8-6-1 PCM Signal Port (J24)................................................................................................................... 18 8-6-2 PCM Loop Settings........................................................................................................................ 19 8-6-3 External I2C Interface to Control Audio Codec .............................................................................. 20 8-7 UART0 & UART1 Signal Port (J23)......................................................21 8-8 Wakeup Control ....................................................................................22 8-8-1 USB Mode ..................................................................................................................................... 22 8-8-2 USB+UART Mode ......................................................................................................................... 23 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁2
  1. FCC Regulations z This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  z This device has been tested and found to comply with the limits for a Class B   digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiated radio frequency   energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that   interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception, which can be determined by   turning the equipment off and on, the user is encouraged to try to correct the   interference by one or more of the following measures:   Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to   which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help.  The maximum antenna gain for frequency 900 is 2 dBi; for frequency 1800 is   2 dBi ;and the antenna separation distance is 20cm. Maximum antenna gain allowed for use with this device is 2 dBi.           Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment.  The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁3
  2. R&TTE Regulations In all cases assessment of the final product must be mass against the Essential   requirements of the R&TTE Directive Articles 3.1(a) and (b), safety and EMC   respectively, as well as any relevant Article 3.3 requirements.  1. Health (Article 3.1(a) of the R&TTE Directive)   Applied Standard(s):                   EN62311:2008  2. Safety (Article 3.1(a) of the R&TTE Directive)   Applied Standard(s):             EN 60950-1:2006/A11:2009/A1:2010/A12:2011   3. Electromagnetic compatibility (Article 3.1 (b) of the R&TTE Directive)   Applied Standard(s):             EN 301 489-1 V1.9.2/-7 V1.3.1/-24 V1.5.1   4. Radio frequency spectrum usage (Article 3.2 of the R&TTE Directive)   Applied Standard(s):    EN 301 511 V9.0.2       EN 301 908-1 V5.2.1/ -2 V5.2.1                  The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁4
  3. RF Exposure Information Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.  This device is intended only for OEM integrators under the following conditions:  1) The antenna must be installed such that 20 cm is maintained between the antenna and users 2) The transmitter module may not be co-located with any other transmitter or antenna.    As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed  IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization.  End Product Labeling This transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in a visible area with the following: “Contains FCC ID: IXM-UNA-P3”. The grantee's FCC ID can be used only when all FCC compliance requirements are met.  Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual.  The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁5 1) The antenna must be installed such that 20 cm is maintained between the antenna and users,      and the maximum antenna gain allowed for use with this device is 2dBi.2) The transmitter module may not be co-located with any other transmitter or antenna.
  4. Information of Installed Module Module Name    UNA-P3/UNA-L3 HW Version    V21 SW Version    V2.4.00101 GSM Band    850, 900, 1800, 1900 UMTS Band    FDD I, FDD II, FDD V GSM Feature    R99   GPRS    Class 12   EDGE    Class 12   UMTS Feature    HSDPA, HSUPA,HSPA+(R7)   AT Command    3GPP TS 27.007, 27.005   SIM/USIM    Support 3V and 1.8V   Interface    USB 2.0 high speed   Operating Temperature    Frequency Stability covers operating temperature range of -20°  to +50°C   Operating Voltage    3.4 ~ 4.2V   The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁6
  User Guide for UNA PLUS Function EVB5.  Illustration of Function EVB   Figure. Layout of Function EVB    The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁7
   Reference  Type  Description  Support  Non-SupportJ8  USB Conn.  Connect host PC or download firmware V  J7  Pin Header  Select external power supplier (+) (Default is ‘Open’.) V  J9  Pin Header  Select external power supply (-) (Default is ‘Open’.) V  SW1  On/off switch  Module on/off control  V   J55  Pin Header  Module on/off control (Default is ‘Open’.) V  J15  Ant. Conn.  Main antenna SMA Connector V  J16  Ant. Conn.  AUX antenna SMA Connector  V  U24  SIM 1 Conn.  Connect SIM Card  V  U21  SIM 2 Conn.  Connect SIM Card  V J18  COM port 0  Debug Pin  V   J19  COM port 1  Transmit/ Receive AT Command.  V   J21  Pin Header Factory Test (Default is ‘Open’.)  V J23  Pin Header UART0 & UART1 signal connector   (Default is ‘Open’.) V  J30  Pin Header Factory Test (Default is ‘Open’.) V  J24  Pin Header PCM signal connector (Default is ‘Open’.) V  J56  Pin Header Wake up AP in AP sleep mode   (wake up AP) (Default is ‘Open’.) V  J54  Pin Header Wake up module in module sleep mode   (wake up modem) (Default is ‘Open’.) V  J2  Headset Conn. EAR PHONE & MIC    V J28  Audio Conn. Audio LINE-OUT    V J29  Audio Conn. Audio LINE-IN    V J42  Switch Conn.  Slide-Style Switch.  V   J52  Pin Header Factory Test (Default is ‘Open’.)  V J51  Pin Header Factory Test (Default is ‘Open’.)  V J57  Pin Header Factory Test (Default is ‘Open’.)  V J34  Pin Header Factory Test (Default is ‘Open’.)  V J35  Pin Header Factory Test (Default is ‘Open’.)  V J50  Pin Header Factory Test (Default is ‘Open’.)  V J22  Pin Header Factory Test (Default is ‘Open’.)  V J25  Pin Header Factory Test (Default is ‘Open’.)  V J26  Pin Header Factory Test (Default is ‘Open’.)  V   The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁8
  6. General Mode 6-1 Setting of Jumpers & Switches    Step7Step6Step5 Step4Step2Step8 Step3 Figure. Settings of general mode    Step1. Remove every jumper on the board.       The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁9
  Step2. Keep ‘R19’ and ‘R20’ short.  R20 R19 Figure. Keep ’R19’ and ‘R20’ short. Step3. For ‘SW1’, select 1-2. (Upper position)  Figure. For ‘SW1’, select 1-2. Step4. For ‘J42’, eight switches should be in ‘OFF’ position.  OFF ONFigure. Switches in ‘OFF’ position.  The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁10
  Step5. Insert SIM card.  Figure. Insert correctly SIM card. Step6. Set up Antenna. a.  Connect bottom of mini card by U.FL cable as following photo.    Figure. Connect by U.FL cable. b.Connect EVB and mini card by U.FL cable. Put mini card on EVB.  Figure. Connect mini card and EVB.  The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁11
  b.  Connect SMA antenna.  Figure. Connect antenna. Step7. Set up Module. an mini card and insert it on the socket, J4. b.  Press mini card until it is stuck a.  By 30 degree angle, le Figure. Insert mini card. by connector, J5.  Figure. Mini card is stuck.  The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁12
   tep8. Connect computer by USB cable. n 60 mm. SRecommended USB cable length is less tha Figure. Connect PC by USB cable.     The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁13
  7. Settings for Download /Update Mode  Component reference  Open/Short  Function Open Close Download/Update mode Pin17-18 in J25  Short  Start Download/Update mode   Step1. Put back the jumper in J25 to short its Pin.17, Pin.18.  Figure. Put back jumper.  Step2. Connect EVB and computer by USB cable.  Figure. Connect PC.  Step3. About SW part, please refer to the file, ‘UNA PLUS Flash Tool User Guide’.   The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁14
  8.  Advance Mode 8-1 Module on/off Control   a. Method 1.    Module Control by SW1. Component reference  Function  SW1,1-2  SW1,2-3 SW1  Control Module  Turn on (Default) Turn off PS2. Please remove the Jump, J55, at first.   b. Method 2.    Module Control by J55. Component reference  Open/Short  Function  Open Shut down (Default) J55  Short Turn on PS3. Please select 2-3 for SW1 at first. (Lower position)  J55  Figure. J55 & SW1  8-2 Voltage Settings  Component reference  Open/Short  Function  Open Supply 3.3Volt to 3G Module. (Default) J12  Short Supply 4.35Volt to 3G Module.    The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁15
  8-3 Use External Power Supplier   Please follow the steps as below. Step1. Remove the jumper, J10 and clear solder on R19. Step2. Connect host PC by USB cable. Step3. J7 is power input, and voltage range is from 3.3V to 4.3V. Step4. J9 is GND.  Figure. J7, J9, J10 & J19             The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁16
  8-4 Current Measurement Step1. Clear solder on R20. Step2. Measure two sides of J11.  Figure. R20, J11   8-5 Settings for Slide-Style Switch (J42) Component reference  Group Function  OFF (Default) ON 1 Factory Test  V   2 Factory Test  V   3 Factory Test   V   4 Factory Test  V   5  Control UART0 (J18)  Open UART0 port    Close UART0 port 6  Control UART1 (J19)  Open UART1 port  Close UART1 port 7  PCM signal select  Import to internal Audio codec  Export to external connector. (J24) J42 8 Factory Test  V   In general mode, these eight switches should be set in ‘OFF’ position.       The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁17
   8-6 PCM Signal   8-6-1 PCM Signal Port (J24) Step1. Group.7 switch in J42 should be in ‘ON’ position as follows.   Step2. Please refer to the following photo to connect ‘J24’.    The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁18
  Step3. Then, please confirm signal level. Default setting is 1.8V. If you’d like 2.8V or 3.3V, please rework EVB by referring to following photos. R60:1.8V(Default) R229:2.8V R234:3.3V Figure. R20, J11 8-6-2 PCM Loop Settings Step1. Please follow 8-6-1. Step2. Put back the jumper in J24 to short its Pin.3 and Pin.5.  Figure. J24 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁19
   8-6-3 External I2C Interface to Control Audio Codec   Step1. Group.7 switch in J42 should be in ‘OFF’ position as follows.  Figure. J42 Step2. AP could control modem by ‘J25’. J25.8 is SCL. J25.10 is SDA. Voltage level is 1.8V. SCL  SDA  Figure. J25  Step3. About Codec init table, please refer to the file, ‘UNA PLUS EVB Codec ReaTtek ALC5637Q Initial Table’.       The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁20
  8-7 UART0 & UART1 Signal Port (J23) Step1. Group.5 (for UART0) & Group.6 (for UART1) switches in J42 should be in ‘ON’ position. UART0  UART1  Figure. Group5&6 switches in J42  Step2. Please refer to the following photo to connect ‘J23’.  2  4  6  8  101357 9Figure. Pin definition of J23 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁21
  Step3. Please confirm signal level. Default setting is 3.3V. If you’d like 1.8V or 2.8V, please refer to the following photo to rework the EVB. Please put back ‘R241’ (default setting) before you use UART0 (J18) and UART1 (J19). R242:1.8V R239:2.8V R241:3.3V(Default)   Figure. Voltage adjustment for UART.  8-8 Wakeup Control 8-8-1 USB Mode Please comply with the following procedures, from step 1 to step 3.   Figure. USB Mode     The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁22
  8-8-2 USB+UART Mode Please comply with the following procedures, from step 1 to step 5.    Figure. USB+UART Mode Operation Procedure Step1. Connect EVB & Host/AP by USB cable.  Figure. Connect Host/AP & EVB Step2. Please refer to Section 4-1, ‘Module on/off control’, to start up modem.   Step3. Connect AP/Host and EVB by ‘J56’, Signal ‘WAKEUP AP’. Voltage level is 1.8V.  Figure. J56, Signal ‘WAKEUP AP’   The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁23
  Step4. Connect AP/Host and EVB by ‘J54.1’, Signal ‘WAKEUP MODEM’. Voltage level is 1.8V. ‘J54.1’ is marked in yellow circle in following picture.  Figure. J54.1, Signal ‘WAKEUP MODEM ’    Step5. Please refer to Section 4-7, ‘UART0 & UART1 Signal Port (J23)’, to connect UART port.  About timing diagram, please refer to the file ‘UNA PLUS IO application design notes’.   Figure. Positions of Pin VABT_M, USB+ and USB-.   The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁24
   Figure. Positions of POWERON (J25.1), WAKEUP AP (J25.3) and WAKEUP MODEM (J25.5).  The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  頁25