Universal Scientific UNA-P3 3G Module User Manual PDD TG SOM RA01
Universal Scientific Industrial Co., Ltd. 3G Module PDD TG SOM RA01
User manual
Doc. Title Originator Date Version UNA Plus/ UNA-Lite Function EVB User Guide Max Shu 2013.10.29 V1.2 Product Line Doc. NO. CONFIDENTIAL UMD (MPC) Low ;Normal High The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. Revision Record Version 1.1 Initial Release Revise content Date 2013.06.06 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 1 Category 1. FCC Regulations ....................................................................................3 2. R&TTE Regulations ..............................................................................4 3. RF Exposure Information......................................................................5 4. Information of Installed Module...........................................................6 5. Illustration of Function EVB.................................................................7 6. General Mode .........................................................................................9 6-1 Setting of Jumpers & Switches ............................................................. 9 7. Settings for Download /Update Mode.................................................14 8. Advance Mode ......................................................................................15 8-1 Module on/off Control........................................................................... 15 8-2 Voltage Settings .................................................................................... 15 8-3 Use External Power Supplier ............................................................... 16 8-4 Current Measurement........................................................................... 17 8-5 Settings for Slide-Style Switch (J42)................................................... 17 8-6 PCM Signal ............................................................................................ 18 8-6-1 PCM Signal Port (J24) ................................................................................................................... 18 8-6-2 PCM Loop Settings........................................................................................................................ 19 8-6-3 External I2C Interface to Control Audio Codec .............................................................................. 20 8-7 UART0 & UART1 Signal Port (J23) ...................................................... 21 8-8 Wakeup Control .................................................................................... 22 8-8-1 USB Mode ..................................................................................................................................... 22 8-8-2 USB+UART Mode ......................................................................................................................... 23 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 2 1. FCC Regulations z This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. z This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. The maximum antenna gain for frequency 900 is 2 dBi; for frequency 1800 is 2 dBi ;and the antenna separation distance is 20cm. Maximum antenna gain allowed for use with this device is 2 dBi. Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 3 2. R&TTE Regulations In all cases assessment of the final product must be mass against the Essential requirements of the R&TTE Directive Articles 3.1(a) and (b), safety and EMC respectively, as well as any relevant Article 3.3 requirements. 1. Health (Article 3.1(a) of the R&TTE Directive) Applied Standard(s): EN62311:2008 2. Safety (Article 3.1(a) of the R&TTE Directive) Applied Standard(s): EN 60950-1:2006/A11:2009/A1:2010/A12:2011 3. Electromagnetic compatibility (Article 3.1 (b) of the R&TTE Directive) Applied Standard(s): EN 301 489-1 V1.9.2/-7 V1.3.1/-24 V1.5.1 4. Radio frequency spectrum usage (Article 3.2 of the R&TTE Directive) Applied Standard(s): EN 301 511 V9.0.2 EN 301 908-1 V5.2.1/ -2 V5.2.1 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 4 3. RF Exposure Information Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This device is intended only for OEM integrators under the following conditions: 1) The antenna must be installed such that 20 cm is maintained between the antenna and users, 1) and The mustantenna be installed such thatfor 20use cmwith is maintained theantenna maximum gain allowed this devicebetween is 2dBi.the antenna and users 2) The transmitter module may not be co-located with any other transmitter or antenna. 2) The transmitter module may not be co-located with any other transmitter or antenna. As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. End Product Labeling This transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in a visible area with the following: “Contains FCC ID: IXM-UNA-P3”. The grantee's FCC ID can be used only when all FCC compliance requirements are met. Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 5 4. Information of Installed Module Module Name HW Version SW Version GSM Band UMTS Band GSM Feature GPRS EDGE UMTS Feature AT Command SIM/USIM Interface Operating Temperature Operating Voltage UNA-P3/UNA-L3 V21 V2.4.00101 850, 900, 1800, 1900 FDD I, FDD II, FDD V R99 Class 12 Class 12 HSDPA, HSUPA,HSPA+(R7) 3GPP TS 27.007, 27.005 Support 3V and 1.8V USB 2.0 high speed Frequency Stability covers operating temperature range of -20° to +50°C 3.4 ~ 4.2V The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 6 User Guide for UNA PLUS Function EVB 5. Illustration of Function EVB Figure. Layout of Function EVB The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 7 Reference Type J8 USB Conn. J7 Pin Header J9 Pin Header Description Connect host PC or download firmware Select external power supplier (+) (Default is ‘Open’.) Select external power supply (-) (Default is ‘Open’.) Support SW1 On/off switch Module on/off control J55 Pin Header Module on/off control (Default is ‘Open’.) J15 Ant. Conn. Main antenna SMA Connector J16 Ant. Conn. AUX antenna SMA Connector U24 SIM 1 Conn. Connect SIM Card U21 SIM 2 Conn. Connect SIM Card J18 COM port 0 Debug Pin J19 COM port 1 Transmit/ Receive AT Command. J21 Pin Header Factory Test (Default is ‘Open’.) J23 Pin Header UART0 & UART1 signal connector (Default is ‘Open’.) J30 Pin Header Factory Test (Default is ‘Open’.) J24 Pin Header PCM signal connector (Default is ‘Open’.) J56 Pin Header J54 Pin Header J2 Wake up AP in AP sleep mode (wake up AP) (Default is ‘Open’.) Wake up module in module sleep mode (wake up modem) (Default is ‘Open’.) Non-Support Headset Conn. EAR PHONE & MIC J28 Audio Conn. Audio LINE-OUT J29 Audio Conn. Audio LINE-IN J42 Switch Conn. Slide-Style Switch. J52 Pin Header Factory Test (Default is ‘Open’.) J51 Pin Header Factory Test (Default is ‘Open’.) J57 Pin Header Factory Test (Default is ‘Open’.) J34 Pin Header Factory Test (Default is ‘Open’.) J35 Pin Header Factory Test (Default is ‘Open’.) J50 Pin Header Factory Test (Default is ‘Open’.) J22 Pin Header Factory Test (Default is ‘Open’.) J25 Pin Header Factory Test (Default is ‘Open’.) J26 Pin Header Factory Test (Default is ‘Open’.) The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 8 6. General Mode 6-1 Setting of Jumpers & Switches Step4 Step7 Step8 Step3 Step5 Step2 Step6 Figure. Settings of general mode Step1. Remove every jumper on the board. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 9 Step2. Keep ‘R19’ and ‘R20’ short. R19 R20 Figure. Keep ’R19’ and ‘R20’ short. Step3. For ‘SW1’, select 1-2. (Upper position) Figure. For ‘SW1’, select 1-2. Step4. For ‘J42’, eight switches should be in ‘OFF’ position. ON OFF Figure. Switches in ‘OFF’ position. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 10 Step5. Insert SIM card. Figure. Insert correctly SIM card. Step6. Set up Antenna. a. Connect bottom of mini card by U.FL cable as following photo. Figure. Connect by U.FL cable. b.Connect EVB and mini card by U.FL cable. Put mini card on EVB. Figure. Connect mini card and EVB. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 11 b. Connect SMA antenna. Figure. Connect antenna. Step7. Set up Module. a. By 30 degree angle, lean mini card and insert it on the socket, J4. Figure. Insert mini card. b. Press mini card until it is stuck by connector, J5. Figure. Mini card is stuck. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 12 Step8. Connect computer by USB cable. Recommended USB cable length is less than 60 mm. Figure. Connect PC by USB cable. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 13 7. Settings for Download /Update Mode Component reference Pin17-18 in J25 Open/Short Function Open Close Download/Update mode Short Start Download/Update mode Step1. Put back the jumper in J25 to short its Pin.17, Pin.18. Figure. Put back jumper. Step2. Connect EVB and computer by USB cable. Figure. Connect PC. Step3. About SW part, please refer to the file, ‘UNA PLUS Flash Tool User Guide’. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 14 8. Advance Mode 8-1 Module on/off Control a. Method 1. Module Control by SW1. Component reference Function SW1,1-2 SW1,2-3 SW1 Control Module Turn on (Default) Turn off PS2. Please remove the Jump, J55, at first. b. Method 2. Module Control by J55. Component reference J55 Open/Short Function Open Shut down (Default) Short Turn on PS3. Please select 2-3 for SW1 at first. (Lower position) J55 Figure. J55 & SW1 8-2 Voltage Settings Component reference J12 Open/Short Function Open Supply 3.3Volt to 3G Module. (Default) Short Supply 4.35Volt to 3G Module. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 15 8-3 Use External Power Supplier Please follow the steps as below. Step1. Remove the jumper, J10 and clear solder on R19. Step2. Connect host PC by USB cable. Step3. J7 is power input, and voltage range is from 3.3V to 4.3V. Step4. J9 is GND. Figure. J7, J9, J10 & J19 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 16 8-4 Current Measurement Step1. Clear solder on R20. Step2. Measure two sides of J11. Figure. R20, J11 8-5 Settings for Slide-Style Switch (J42) Component reference J42 Group Function OFF (Default) Factory Test Factory Test Factory Test Factory Test Control UART0 (J18) Control UART1 (J19) PCM signal select Factory Test Open UART0 port Open UART1 port Import to internal Audio codec ON Close UART0 port Close UART1 port Export to external connector. (J24) In general mode, these eight switches should be set in ‘OFF’ position. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 17 8-6 PCM Signal 8-6-1 PCM Signal Port (J24) Step1. Group.7 switch in J42 should be in ‘ON’ position as follows. Step2. Please refer to the following photo to connect ‘J24’. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 18 Step3. Then, please confirm signal level. Default setting is 1.8V. If you’d like 2.8V or 3.3V, please rework EVB by referring to following photos. R234:3.3V R229:2.8V R60:1.8V(Default) Figure. R20, J11 8-6-2 PCM Loop Settings Step1. Please follow 8-6-1. Step2. Put back the jumper in J24 to short its Pin.3 and Pin.5. Figure. J24 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 19 8-6-3 External I2C Interface to Control Audio Codec Step1. Group.7 switch in J42 should be in ‘OFF’ position as follows. Figure. J42 Step2. AP could control modem by ‘J25’. J25.8 is SCL. J25.10 is SDA. Voltage level is 1.8V. SCL SDA Figure. J25 Step3. About Codec init table, please refer to the file, ‘UNA PLUS EVB Codec ReaTtek ALC5637Q Initial Table’. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 20 8-7 UART0 & UART1 Signal Port (J23) Step1. Group.5 (for UART0) & Group.6 (for UART1) switches in J42 should be in ‘ON’ position. UART0 UART1 Figure. Group5&6 switches in J42 Step2. Please refer to the following photo to connect ‘J23’. 2 4 6 8 10 1 3 5 7 Figure. Pin definition of J23 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 21 Step3. Please confirm signal level. Default setting is 3.3V. If you’d like 1.8V or 2.8V, please refer to the following photo to rework the EVB. Please put back ‘R241’ (default setting) before you use UART0 (J18) and UART1 (J19). R242:1.8V R239:2.8V R241:3.3V(Default) Figure. Voltage adjustment for UART. 8-8 Wakeup Control 8-8-1 USB Mode Please comply with the following procedures, from step 1 to step 3. Figure. USB Mode The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 22 8-8-2 USB+UART Mode Please comply with the following procedures, from step 1 to step 5. Figure. USB+UART Mode Operation Procedure Step1. Connect EVB & Host/AP by USB cable. Figure. Connect Host/AP & EVB Step2. Please refer to Section 4-1, ‘Module on/off control’, to start up modem. Step3. Connect AP/Host and EVB by ‘J56’, Signal ‘WAKEUP AP’. Voltage level is 1.8V. Figure. J56, Signal ‘WAKEUP AP’ The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 23 Step4. Connect AP/Host and EVB by ‘J54.1’, Signal ‘WAKEUP MODEM’. Voltage level is 1.8V. ‘J54.1’ is marked in yellow circle in following picture. Figure. J54.1, Signal ‘WAKEUP MODEM ’ Step5. Please refer to Section 4-7, ‘UART0 & UART1 Signal Port (J23)’, to connect UART port. About timing diagram, please refer to the file ‘UNA PLUS IO application design notes’. Figure. Positions of Pin VABT_M, USB+ and USB-. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 24 Figure. Positions of POWERON (J25.1), WAKEUP AP (J25.3) and WAKEUP MODEM (J25.5). The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 頁 25
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Company : USI Source Modified : D:20131120054452 Create Date : 2013:11:20 13:47:04+08:00 Creator Tool : Acrobat PDFMaker 6.0 for Word Metadata Date : 2013:11:21 11:40:23+08:00 Modify Date : 2013:11:21 11:40:23+08:00 Document ID : uuid:5d8b1ef2-eab2-4bff-ae8f-3f460d6ce6d0 Instance ID : uuid:40cbddba-c8ab-4714-ad38-dc098e845413 Version ID : 2 Format : application/pdf Title : PDD TG SOM (RA01) Creator : CH Hong Description : Board Design Operation Subject : Producer : PDF-XChange Viewer [Version: 2.0 (Build 42.8) (Nov 9 2009; 18:19:58)] Headline : Board Design Operation Page Count : 26 Author : CH HongEXIF Metadata provided by EXIF.tools