Universal Scientific UNA850 UNA 850 module User Manual UNA 850 UserMan

Universal Scientific Industrial Co., Ltd. UNA 850 module UNA 850 UserMan

user manual

    The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.         Doc. Title    User Guide for UNA Module and Socket EVB (V23) Originator    Max Shu Date  2012/09/07 Version    DVT V23
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  Revision Record Version  Revise content  Date 1.0  New release  2012-08-10 1.1  1.Add EVB test point pin define 2. Identification of PCB version 2012-09-07
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  Content 1. FCC Regulations............................................................................................3 2. RF Exposure Information..............................................................................4 3. Information of Installed Module....................................................................5 4. Guide to Use ..................................................................................................6 1) Function of Socket EVB V23 and Identification of PCB version................6 2) Configure the Socket EVB............................................................................ 8 3) Insert the SIM card..................................................................................... 11 4) Place the Module ....................................................................................... 12 5) Connect the antenna..................................................................................13 6) Download setting........................................................................................ 14 7) Manual control module sleep mode:........................................................... 15 8) Apply External power to module................................................................. 16 9) Measure current of module setting............................................................. 17 10) Connect extend cable for line in & line out :................................................ 18 11) EVB test point pin define............................................................................19
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.   1.  FCC Regulations    This device complies with part 15 of the FCC Rules. Operation is subject to the  following  two  conditions:  (1)  This  device  may  not  cause  harmful interference,  and  (2)  this  device  must  accept  any  interference  received, including interference that may cause undesired operation.    This device has been tested and found to comply with the limits for a Class B  digital  device,  pursuant to  Part 15  of the  FCC  Rules.  These limits  are designed to provide reasonable protection against harmful interference in a residential  installation.  This  equipment  generates,  uses  and  can  radiated radio frequency energy and,  if  not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However,  there  is  no  guarantee  that  interference  will  not  occur  in  a particular installation If this equipment does cause harmful interference to radio  or  television  reception,  which  can  be  determined  by  turning  the equipment  off  and  on,  the  user  is  encouraged  to  try  to  correct  the interference by one or more of the following measures:    Reorient or relocate the receiving antenna.   Increase the separation between the equipment and receiver.   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   Consult the dealer or an experienced radio/TV technician for help.  Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment.
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  2.  RF Exposure Information  This  Modular  Approval  is  limited  to  OEM  installation  for  mobile  and  fixed applications only.   The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna  gain  and  cable  loss  must  satisfy  MPE  categorical  Exclusion Requirements of §2.1091.    The  antenna(s)  used  for  this  transmitter  must  be  installed  to  provide  a separation distance of at least 20 cm from all persons, must not be collocated or  operating  in  conjunction  with  any  other  antenna  or  transmitter,  except  in accordance with FCC multi-transmitter product procedures.   The end user has no manual instructions to remove or install the device and a separate  approval  is  required for  all  other operating configurations,  including portable  configurations  with  respect  to  2.1093  and  different  antenna configurations.  Maximum antenna gain allowed for use with this device is 2 dBi. When the module is installed in the host device, the FCC ID label must be visible through a window on the final device or it must be visible when an access panel, door or cover is easily re-moved. If not, a second label must be placed on the outside of the final device that contains the following text: “Contains FCC ID: IXM-UNA850”.
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  3.  Information of Installed Module  Module Name UNA_850 FCC ID   IXM-UNA850 HW Version V2.3 SW Version V3.1a GSM Band GSM 850, E-GSM 900, DCS 1800, PCS 1900  UMTS Band FDD I, FDD V GSM Feature Release 99 GPRS Release 6, Multi-slot class 12 EDGE Release 6, Multi-slot class 12 UMTS Feature HSDPA, HSUPA (UMTS Release 6) AT Command 3GPP TS 27.007, 27.005 SIM/USIM Support 3V and 1.8V Interface USB 2.0 high speed Operating Temperature Frequency Stability covers operating temperature range of -20° to +50°C Operating Voltage 3.3 ~ 4.2V
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  4.  Guide to Use  1) Function of Socket EVB V23 and Identification of PCB version
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.    Function    Description  Available  Unavailable USB PORT    Connect to Host PC and Download Firmware  V     Power supply IN    Optional Connect to external Power supply input  V     UART1  Download Firmware  V     RF SMA connector    Connect to external Antenna  V     SIM card    Connect to SIM card    V     LINE IN  Connect to Line in  V   LINE OUT  Connect to Line out  V     J51  MP test connector  V    J52  MP test connector  V
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  2) Configure the Socket EVB  Default JUMP Setting :     Note1 :For current measurement of VBAT_M: de-solder R808. Close J40 Note2 :For current measurement of VBAT_M1: de-solder R809. Close J41 Component reference    Function    Jump 1-2 (Default) Output +3.3V for module    No  J42  Output +4.2V for module    Yes  Component reference    Function    Jump 1-2 J45  USB_EN high level input to turn on Module  No J53  PWRKEY high level input to turn on Module  No  Component reference    Function    Jump 1-2 J40  Enable VBAT_M. (Default) R808 short. No, Note1 J41  Enable VBAT_M1.(Default) R809 short. No, Note2
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  Download Key : Component reference    Function    Jump 1-2 J31  Enable Download through USB  No, Note3 Note 3: To enable download mode, Please close J31 and refer to “ Use Data Card Tool To Update Image File Steps-V1.1-2012.07.18.pdf”  Jump setting for normal mode .    Component reference  JUMP 1-2 J40  NO J41  NO J42  NO J31  NO J45  NO
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  J53  NO Jump setting for Download mode :    Component reference  JUMP 1-2 J40  NO J41  NO J42  NO J31  YES J45  NO J53  NO
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.   3) Insert the SIM card  To use a UNA module, you need to install: a.  A live SIM card (with an active account), or b.  A test SIM card for use with call box (for example ,an Agilent 8960 ..)  To install the SIM card: a.  Place the Socket EVB face-up(as shown) – the SIM slot is on right side. b.  Note the location of the notched corner of the card in the following image.   c. Inset the SIM card into the slot.
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.    4) Place the Module  After inserting the SIM card, insert the module: a. Place the Socket EVB face-up(as shown) – the socket is in the center.        b. Notice the pin 1 location on the socket.
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.    5) Connect the antenna  After installing the Module ,connect the supplied antenna to the EVB a.  Place the Socket EVB face-up. The antenna connector on the bottom side.      b.  Connect the antenna to the adapter.
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.    6) Download setting  a.  Plug in the Jump.   b.Connect the USB cable between EVB & PC.
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.    7) Manual control module sleep mode:  Component reference    Function   J45  USB_EN input for sleep / normal mode a.  Follow UNA IO application design notes b.  Plug in the Jump from J45 before use manual control.   c.  Connect    J51,16pin to control module .    J51,16pin: Hi(3.3~5.0V): Normal mode ; Low(0~0.3V): Sleep mode
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.    8) Apply External power to module  To use external power for module, please follow the steps to setting. a.  Red line VCC connect to J38. b.  Black line GND connect to J39. c.  De-solder the open pad R808.(yellow circle) d.  USB cable connect to Host PC.
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  9) Measure current of module setting  a.  De-solder the open pad R809.(yellow circle)   b.  Please follow the photo to setup the current meter.
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  10) Connect extend cable for line in & line out :
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.  11) EVB test point pin define  1.  J52 Pin define   Pin number Pin name  Pin number Pin name 1  GND  2  VBAT_M1 3  DAICLK  4  DAISYNC 5  DAIPCMOUT  6  DAIPCMIN 7  SCL  8  DAIRST 9  SDA  10  Reserve Pin 11  Reserve Pin  12  Reserve Pin 13  URXD2  14  UTXD2 15  URXD1  16  UTXD1
    The information  contained herein  is  the exclusive property of  Universal Scientific Industrial  Co., Ltd.  and  shall not  be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.     2.J51 Pin define   Pin number Pin name  Pin number Pin name 1  GND  2  AP_Ready 3  Wake  4  #W_Disable 5  #EINT9  6  ID                    (Note4) 7  GPIO2  8  GPIO1 9  GPIO0  10  #Sys_config      (Note5) 11  Reserve Pin  12  Reserve Pin 13  KROW0  14  KCOL6 15  Reserve Pin  16  Reserve Pin Note4: Default- open (900 module);If use 850 module, this pin to pull low(1kΩΩΩΩ). Note5: enable "USB+UART "mode-Default- open (USB only);If use”USB+UART” mode, this pin to pull low(1kΩΩΩΩ).

Navigation menu