Universal Scientific UNA850 UNA 850 module User Manual UNA 850 UserMan
Universal Scientific Industrial Co., Ltd. UNA 850 module UNA 850 UserMan
user manual
Doc. Title Originator User Guide for UNA Module and Socket EVB (V23) Max Shu Date 2012/09/07 Version DVT V23 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. Revision Record Version 1.0 1.1 Revise content New release 1.Add EVB test point pin define 2. Identification of PCB version Date 2012-08-10 2012-09-07 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. Content 1. FCC Regulations............................................................................................ 3 2. RF Exposure Information.............................................................................. 4 3. Information of Installed Module.................................................................... 5 4. Guide to Use .................................................................................................. 6 1) Function of Socket EVB V23 and Identification of PCB version................ 6 2) Configure the Socket EVB............................................................................ 8 3) Insert the SIM card..................................................................................... 11 4) Place the Module ....................................................................................... 12 5) Connect the antenna .................................................................................. 13 6) Download setting........................................................................................ 14 7) Manual control module sleep mode:........................................................... 15 8) Apply External power to module................................................................. 16 9) Measure current of module setting ............................................................. 17 10) Connect extend cable for line in & line out :................................................ 18 11) EVB test point pin define ............................................................................ 19 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 1. FCC Regulations This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 2. RF Exposure Information This Modular Approval is limited to OEM installation for mobile and fixed applications only. The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons, must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. The end user has no manual instructions to remove or install the device and a separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations. Maximum antenna gain allowed for use with this device is 2 dBi. When the module is installed in the host device, the FCC ID label must be visible through a window on the final device or it must be visible when an access panel, door or cover is easily re-moved. If not, a second label must be placed on the outside of the final device that contains the following text: “Contains FCC ID: IXM-UNA850”. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 3. Information of Installed Module Module Name UNA_850 FCC ID IXM-UNA850 HW Version V2.3 SW Version V3.1a GSM Band GSM 850, E-GSM 900, DCS 1800, PCS 1900 UMTS Band FDD I, FDD V GSM Feature Release 99 GPRS Release 6, Multi-slot class 12 EDGE Release 6, Multi-slot class 12 UMTS Feature HSDPA, HSUPA (UMTS Release 6) AT Command 3GPP TS 27.007, 27.005 SIM/USIM Support 3V and 1.8V Interface USB 2.0 high speed Operating Temperature Frequency Stability covers operating temperature range of -20° to +50°C Operating Voltage 3.3 ~ 4.2V The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 4. Guide to Use 1) Function of Socket EVB V23 and Identification of PCB version The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. Function Description Available USB PORT Connect to Host PC and Download Firmware Power supply IN Optional Connect to external Power supply input UART1 Download Firmware RF SMA connector Connect to external Antenna SIM card Connect to SIM card LINE IN Connect to Line in LINE OUT Connect to Line out J51 MP test connector J52 MP test connector Unavailable The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 2) Configure the Socket EVB Default JUMP Setting : Component reference Function Jump 1-2 J40 Enable VBAT_M. (Default) R808 short. No, Note1 J41 Enable VBAT_M1.(Default) R809 short. No, Note2 Note1 :For current measurement of VBAT_M: de-solder R808. Close J40 Note2 :For current measurement of VBAT_M1: de-solder R809. Close J41 Component reference J42 Component reference Function Jump 1-2 (Default) Output +3.3V for module No Output +4.2V for module Yes Function Jump 1-2 J45 USB_EN high level input to turn on Module No J53 PWRKEY high level input to turn on Module No The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. Download Key : Component reference J31 Function Enable Download through USB Jump 1-2 No, Note3 Note 3: To enable download mode, Please close J31 and refer to “ Use Data Card Tool To Update Image File Steps-V1.1-2012.07.18.pdf” Jump setting for normal mode . Component reference JUMP 1-2 J40 NO J41 NO J42 NO J31 NO J45 NO The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. J53 NO Jump setting for Download mode : Component reference JUMP 1-2 J40 NO J41 NO J42 NO J31 YES J45 NO J53 NO The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 3) Insert the SIM card To use a UNA module, you need to install: a. A live SIM card (with an active account), or b. A test SIM card for use with call box (for example ,an Agilent 8960 ..) To install the SIM card: a. Place the Socket EVB face-up(as shown) – the SIM slot is on right side. b. Note the location of the notched corner of the card in the following image. c. Inset the SIM card into the slot. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 4) Place the Module After inserting the SIM card, insert the module: a. Place the Socket EVB face-up(as shown) – the socket is in the center. b. Notice the pin 1 location on the socket. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 5) Connect the antenna After installing the Module ,connect the supplied antenna to the EVB a. Place the Socket EVB face-up. The antenna connector on the bottom side. b. Connect the antenna to the adapter. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 6) Download setting a. Plug in the Jump. b.Connect the USB cable between EVB & PC. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 7) Manual control module sleep mode: Component reference J45 Function USB_EN input for sleep / normal mode a. Follow UNA IO application design notes b. Plug in the Jump from J45 before use manual control. c. Connect J51,16pin to control module . J51,16pin: Hi(3.3~5.0V): Normal mode ; Low(0~0.3V): Sleep mode The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 8) Apply External power to module To use external power for module, please follow the steps to setting. a. Red line VCC connect to J38. b. Black line GND connect to J39. c. De-solder the open pad R808.(yellow circle) d. USB cable connect to Host PC. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 9) Measure current of module setting a. De-solder the open pad R809.(yellow circle) b. Please follow the photo to setup the current meter. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 10) Connect extend cable for line in & line out : The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 11) EVB test point pin define 1. J52 Pin define Pin number Pin name GND DAICLK 11 13 15 DAIPCMOUT SCL SDA Reserve Pin URXD2 URXD1 Pin number Pin name VBAT_M1 DAISYNC 10 12 14 16 DAIPCMIN DAIRST Reserve Pin Reserve Pin UTXD2 UTXD1 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 2.J51 Pin define Pin number Pin name GND Wake 11 13 15 #EINT9 GPIO2 GPIO0 Reserve Pin KROW0 Reserve Pin Pin number Pin name AP_Ready #W_Disable 10 12 14 16 ID GPIO1 #Sys_config Reserve Pin KCOL6 Reserve Pin (Note4) (Note5) Note4: Default- open (900 module);If use 850 module, this pin to pull low(1kΩ Ω). Note5: enable "USB+UART "mode- Default- open (USB only);If use”USB+UART” mode, this pin to pull low(1kΩ Ω). The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Producer : GPL Ghostscript 9.02 Keywords : Modify Date : 2012:09:26 19:33:40+08:00 Create Date : 2012:09:25 20:49:21+08:00 Creator Tool : PDFCreator Version 1.2.2 Metadata Date : 2012:09:26 19:33:40+08:00 Document ID : f4a7644d-096a-11e2-0000-921201863e96 Instance ID : uuid:2d85751b-daae-4930-b267-d7dc12aa7947 Format : application/pdf Title : UNA_850_UserMan Creator : Admin Description : Description (x-repair) : Page Count : 21 Author : Admin Subject :EXIF Metadata provided by EXIF.tools