VALEO Telematik und Akustik V1140-100 GSM/GPRS/UMTS/HSDPA/HSUPA Module User Manual 08 user guide

Peiker acustic GmbH & Co. KG GSM/GPRS/UMTS/HSDPA/HSUPA Module 08 user guide

08 user guide

Download: VALEO Telematik und Akustik V1140-100 GSM/GPRS/UMTS/HSDPA/HSUPA Module User Manual 08 user guide
Mirror Download [FCC.gov]VALEO Telematik und Akustik V1140-100 GSM/GPRS/UMTS/HSDPA/HSUPA Module User Manual 08 user guide
Document ID2382289
Application IDIKMiOPJk4NJMJxPTezEM/A==
Document Description08 user guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize127.93kB (1599153 bits)
Date Submitted2014-09-09 00:00:00
Date Available2015-03-08 00:00:00
Creation Date2014-09-03 11:59:44
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2014-09-03 11:59:44
Document Title08 user guide
Document CreatorMicrosoft® Office Word 2007
Document Author: PEIKER acustic

User manual
LTE-NAD V1140-xxx
Peiker product ID:
2189-140-xxx-00 (V1140-xxx)
Revision:
Date:
0.10
August 2014
Status:
Draft
_______________________________________________________________________________________________________________ Seite 1
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
History:
Date
Revision
15.09.2013 0.5
13.12.2013 0.6
16.12.2013
01.04.2014
17.06.2014
24.06.2014
31.07.2014
08.08.2014
0.7
0.8
0.9
0.9.1
0.10
0.11
Name Comment
wlo
Initial document
phse
Some additions to sections 2.1 and 3.3
Some corrections to section 2.2, Figure 4 updated
phse
Some additions to section 8
phse
Modifications/additions to section 8
phse
Updated Max Antenna Gain Values in section 8.3
wlo
Added FW update and WIN7 driver installation
phse
Added FCC labeling requirements of V1140-100
phse
Modifications/additions to sections 8.1, 8.1.1 and 8.2
_______________________________________________________________________________________________________________ Seite 2
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Content
Introduction ..........................................................................................................................................5
1.1 Scope ..................................................................................................................................................5
1.2 Audience ............................................................................................................................................5
1.3 Contact information, Support .........................................................................................................5
1.4 Related Documents ..........................................................................................................................5
Overview ...............................................................................................................................................6
2.1 Product Variants................................................................................................................................ 6
2.2 Features .............................................................................................................................................7
2.3 Approvals ...........................................................................................................................................7
Overview ...............................................................................................................................................8
3.1 HW Features ......................................................................................................................................8
3.2 Connectors .........................................................................................................................................8
3.2.1 Module Signal and RF Connectors ..........................................................................................8
3.2.2 Ground and Heat Dissipation Connectors..............................................................................8
3.3 Main Interfaces .................................................................................................................................8
3.3.1 USB ..............................................................................................................................................8
3.3.2 SIM Interface ............................................................................................................................. 9
3.3.3 Power on.....................................................................................................................................9
3.3.4 Reset ...........................................................................................................................................9
3.3.5 GPIOs ..........................................................................................................................................9
3.3.6 GSBIs.........................................................................................................................................10
3.3.7 Module Pin-out......................................................................................................................... 11
3.4 Supply Voltage ................................................................................................................................ 15
3.5 Power Consumption .......................................................................................................................15
3.6 Transmitter ......................................................................................................................................16
3.7 Receiver ...........................................................................................................................................16
3.8 Environmental Specification ..........................................................................................................16
3.8.1 Temperature Range ................................................................................................................16
Evaluation Kit .....................................................................................................................................17
4.1 Overview ......................................................................................................................................17
4.2 Firmware Update ........................................................................................................................21
4.2.1 Identify Qualcomm Diagnostics Port Number.....................................................................21
4.2.2 Install and Run FW Executable ............................................................................................. 21
4.2.3 Known Issues ........................................................................................................................... 22
4.3 Windows 7 Driver Installation ...................................................................................................23
4.3.1 Driver installation.................................................................................................................23
4.3.2 Available interfaces .............................................................................................................23
4.3.3 AT Command interface and PPP Dial-up Modem connection .......................................23
4.3.4 RmNet NDIS connection as Network Interface Card .....................................................25
4.3.5 Diagnostics interface ...........................................................................................................26
4.3.6 NMEA GNSS interface .........................................................................................................26
AT Command Set............................................................................................................................... 26
Safety Recommendations according to EN60950-1 .....................................................................28
List of Acronyms ................................................................................................................................ 29
_______________________________________________________________________________________________________________ Seite 3
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
8
Regulatory Certifications ..................................................................................................................30
8.1 USA (FCC) ........................................................................................................................................30
_______________________________________________________________________________________________________________ Seite 4
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
1
Introduction
1.1 Scope
This document gives an overview about electrical, mechanical and functional detail of the peiker LTENAD v1140-xxx.
1.2 Audience
Information to integrate the module in other applications.
1.3 Contact information, Support
peiker acustic GmbH & Co KG
Max-Planck Street 32
D-61381 Friedrichsdorf / Ts.
Germany
http://www.peiker.de
info@peiker.de
1.4 Related Documents
None.
_______________________________________________________________________________________________________________ Seite 5
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
2
Overview
2.1 Product Variants
The LTE-NAD is available in multiple product variants:
Peiker product #
2189-140-100-00 (V1140-100)
2189-140-101-00 (V1140-101)
2189-140-103-00 (V1140-103)
2189-140-104-00 (V1140-104)
2189-140-105-00 (V1140-105)
2189-140-106-00 (V1140-106)
Module configuration
LTE EU configuration
LTE North America configuration
2G/3G EU/RoW configuration
LTE Asia Pacific configuration
2G/3G North America configuration
2G/3G China configuration
All variants include Quad band GSM/GPRS/EDGE (850, 900, 1800, 1900 MHz)
V1140-100
LTE Bands
WCDMA Bands
B3, B7, B20
FDD1, FDD8
V1140-101
LTE Bands
WCDMA Bands
B2, B4, B5, B17
FDD2, FDD5
V1140-103
LTE Bands
WCDMA Bands
No LTE support
FDD1, FDD2, FDD5, FDD6, FDD8
V1140-104
LTE Bands
WCDMA Bands
B1, B3, B5, B7, B19
FDD1, FDD5, FDD6, FDD8
V1140-105
LTE Bands
WCDMA Bands
No LTE support
FDD2, FDD5
V1140-106
LTE Bands
WCDMA Bands
No LTE support
FDD1
_______________________________________________________________________________________________________________ Seite 6
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
2.2 Features
Features
Same footprint and pin-out for all modules
Voice and data calls are supported in all modules
GSM (R99, GPRS and EDGE) for all modules
WCDMA (R99, R5 HSDPA, R6 HSUPA and R7 HSPA+) for all modules
WCDMA (R8 DC-HSPA+) for all modules except for V1140-101 and V1140-105
LTE (Rel.9 Cat3 FDD) for LTE capable modules
DTM/eDTM
eCall inband modem
Standalone GPS, GLONASS, AGPS (MS-Assisted and MS-Based)
Data rates
- GSM: DL/UL – 14.4kbps / 14.4kbps
GPRS: Multislot class 12, DL/UL – 85.6kbps / 42.8kbps
EDGE: Multislot class 12, DL/UL – 236.8kbps / 118.4kbps
- WCDMA: DL/UL up to 384kbps
HSPA+:
Category 24 in DL using 64 QAM and Dual-Cell; Up to 42 Mbps – Not supported by
V1140-101 and V1140-105
Category 14 in DL using 64 QAM; Up to 21 Mbps
Category 6 in UL using 16 QAM; Up to 5.76 Mbps
- LTE-FDD Category 3: Up to 100 Mbps in DL, up to 50 Mbps in UL
Power Classes
LTE: All supported bands, Power Class 3
WCDMA: All supported bands, Power Class 3
EDGE: 850 MHz / 900 MHz / 1800 MHz/ 1900MHz, Power Class E2
GSM / GPRS: 850 MHz / 900MHz, Power Class 4
GSM / GPRS: 1800 MHz / 1900MHz, Power Class 1
Dimension and Weight
Dimensions: 31mm x 46mm x 4mm
Weight < 10 grams
2.3 Approvals
R&TTE directive
CE, GCF
FCC, IC, PTCRB
AT&T
_______________________________________________________________________________________________________________ Seite 7
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
3
Overview
3.1 HW Features
Qualcomm SoC (system on chip)
o LTE capable modules V1140-100, V1140-101 and V1140-104
MDM9215 Baseband / PMIC8018 Power management / WTR1605L
o Non-LTE modules
V1140-103, V1140-105 and V1140-106
MDM8215 Baseband / PMIC8018 Power management / WTR1605
Cortex A5 Core up to 550 MHz
3 DSPs for modem and low power audio sub systems
RPM Resource and power manager
2Gb NAND Flash x16,
2Gb Low Power Mobile DDR SDRAM x32
19.2MHz clock reference
Dedicated heat sink in center area underneath the PCB
GPS/GLONASS operation, GPS antenna biasing and diagnostics
3.2 Connectors
3.2.1 Module Signal and RF Connectors
The LTE-NAD has 172 signal pins (2xAA and 2xBB) connector pads with 1.0mm pitch. The signal pads
are located close to the board edges.
There
are three antenna pads, each collocated by RF GND connectors
Main transmit and receive antenna – pin LGA_PRX_ANT
Diversity antenna for WCDMA respective MIMO antenna for LTE – pin LGA_DRX_ANT_IN
GNSS antenna for both GPS and GLONASS – pin LGA_GPS_DRX_ANT
3.2.2 Ground and Heat Dissipation Connectors
To support the usage of module under complicated thermal conditions, there are a number of large
grounded pads in the center of PCB. These pads are dedicated ground pads to transfer heat dissipation
to a carrier board.
This should be especially considered by customer designs. A reference design showing landing patterns
and PCB stack-up is available on request.
3.3 Main Interfaces
3.3.1 USB
The NAD has one USB2.0 OTG high speed (480MBit) compliant interface including the PHY. The IF
consists of 5 signals:
_______________________________________________________________________________________________________________ Seite 8
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
-
USB_D_P:
USB_D_M:
USB_ID:
USB_VBUS:
VREG_USB3_3V075
USB Data Plus signal
USB Data Minus signal
Master/Slave Configuration1
USB Voltage Supply
USB Voltage Output
A dynamic reconfiguration between USB-Host or USB-Device is not foreseen, the NAD can be configured
to USB-Host or USB-Device by the insertion of a resistor on the USB_ID line.
3.3.2 SIM Interface
The NADs SIM interface is compatible to 1.8V and 3V SIM Cards, the necessary voltage and level shifting
is handle by LTE-NAD automatically. The IF consists of the following signals:
VREG_USIM
USIM_CLK
USIM_DATA
USIM_RESET
The data speed on the SIM IF is up to 4 Mbps, so HW designers should take care of the length and
routing of the SIM IF to prevent potential EMC problems.
3.3.3 Power on
The signal PON_N is used switch on the NAD-Module. PON_N is pulled against VMAIN on the
LTE-NAD internally.
Due to this fact it is recommended to pull this input against GND using an open collector or
open drain output only.
3.3.4 Reset
EXT_RESIN_N is used to reset the LTE-NAD-Module, see table of LTE-NAD signal pins.
There are further reset signals available, please check .
RES_IN is pulled against VMAIN power on the LTE-NAD internally. Therefore, it is
recommended to pull this input against GND using an open collector or open drain output only.
3.3.5 GPIOs
The LTE-NAD is configured in the slave mode. For other configuration of the USB – Interface please contact
peiker acustic GmbH & Co.KG.
_______________________________________________________________________________________________________________ Seite 9
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
There are 51 GPIOs on the LTE-NAD module available. Most of them are part of the 5 GSBIs provided
in next chapter. They are used for different interfaces (see Table 1 and the following chapters). For
allocation of GPIOs/GSBIs to different configurations please contact peiker acustics GmbH & Co.KG
GPIOs and GSBIs share the same output pins and may not available when used as GSBI configuration.
The following GPIOs are not belonging to a GSBI bundle:
GPIO 47, 72, 82, 25, 28, 26, 27, 84, 80, 21, 23, 22, 24, 20, 1, 78, 79, 85, 86, 69, 0, 77, 65, 61, 68, 51, 54,
73, 48, 49, 53.
The following GPIOs are belonging to a GSBI bundle:
GPIO 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 29, 30.
3.3.6 GSBIs
Each GSBI (General Serial Bus Interface) consists of a bundle of 4 GPIOs. 5 GSBI are available.
The reference voltage is of the GSBIs is 1.8V.
Available signals on GSBI bundles at the board to board connector:
GSBI1:
GSBI2:
GSBI3:
GSBI4:
GSBI5:
GSBI1_0, GSBI1_1, GSBI1_2, GSBI1_3 (GPIO_29, 30, 2, 3)
GSBI2_0, GSBI2_1, GSBI2_2, GSBI2_3 (GPIO_4, 5, 6, 7)
GSBI3_0, GSBI3_1, GSBI3_2, GSBI3_3 (GPIO_8, 9, 10, 11)
GSBI4_0, GSBI4_1, GSBI4_2, GSBI4_3 (GPIO_12, 13, 14, 15)
GSBI5_0, GSBI5_1, GSBI5_2, GSBI5_3 (GPIO_16, 17, 18, 19)
For the standard configuration of the GSBIs see the following Fehler! Verweisquelle konnte nicht
gefunden werden. 3.
_______________________________________________________________________________________________________________ Seite 10
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Figure 1 V1140-xxx General Serial Bus Interface GSBI interface configuration
3.3.7 Module Pin-out
Table 1
Module Pin-out
PIN
Signal
2 – 22
23
24
25
26
27
28
GND
GND
GPIO47
JTAG_TDI
JTAG_TDO
GPIO_72
JTAGTMS
JTAG_TRST_N
Direction related
to LTE-NAD
Input Power
Input Power
Input
Input
Output
IN/OUT
Input
Input
Comment
Main ground connection, Corner pad
Main ground connection
WDOG_DISABLE
JTAG Interface
JTAG Interface
JTAG Interface
JTAG Interface
_______________________________________________________________________________________________________________ Seite 11
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
PIN
Signal
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
JTAG_RTCK
GND
JTAG_TCK
JTAG_RESOUT_N
GPIO82
JTAG_PS_HOLD
EXT_RESIN_N
GND
RESOUT_N
GPIO29_ SDC2_CMD
GPIO25_ SDC2_D0
GPIO28_ SDC2_D3
GPIO30_ SDC2_CLK
GND
GPIO26_ SDC2_D1
GPIO27_ SDC2_D2
PM_GPIO4
GPIO84
GND
SDC1_CMD
SDC1_DATA0
SDC1_DATA3
SDC1_CLK
GPIO80_SDC1_DET_N
GND
SDC1_DATA2
SDC1_DATA1
GPIO21_ I2S_WS
GPIO23_ I2S_DOUT
GPIO22_ I2S_DIN
GPIO24_ I2S_MCLK
GND
GPIO20_ I2S_CLK
GPIO19_GSBI5_3
GPIO17_GSBI5_1
GPIO18_GSBI5_2
GPIO15_GSBI4_3
GND
Direction related
to LTE-NAD
Output
Input Power
Input
Input
Output
Input
Input
Input Power
Output
IN/OUT
IN/OUT
IN/OUT
Output
Input Power
IN/OUT
IN/OUT
IN/OUT
Output
Input Power
IN/OUT
IN/OUT
IN/OUT
Output
IN/OUT
Input Power
IN/OUT
IN/OUT
Output
Output
Input
Output
Input Power
Output
Output
IN/OUT
Input
Output
Input Power
67
USB_D_P
IN/OUT
68
USB_D_M
IN/OUT
69
70
GND
Input Power
Input
GPIO14_GSBI4_2
Comment
JTAG Interface
Main ground connection
JTAG Interface
JTAG Interface
NAD – Runnig, Controll signal
JTAG Interface
Input Reset for LTE-NAD module
Main ground connection
Output Reset
SD Card CMD
SD Card Data 0
SD Card Data 3
SD Card Clock
Main ground connection
SD Card Data 1
SD Card Data 2
Reset of the Codec
Main ground connection
SD Card CMD
SD Card Data 0
SD Card Data 3
SD Card Clock
Main ground connection, Corner pad
SD Card Data 2
SD Card Data 1
I²S - Word Select
I²S – Data Output
I²S - Data Input
I²S - Master Clock
Main ground connection
I²S - Clock
2 – Pin – UART TXD 3
I²C – Serial Data
2 – Pin – UART RXD 3
4 – Pin – UART TXD 1
Main ground connection
High – Speed USB Device for
communication
High – Speed USB Device for
communication
Main ground connection
4 – Pin – UART RXD 1
_______________________________________________________________________________________________________________ Seite 12
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
PIN
Signal
71
72
73
74
75
GPIO13_GSBI4_1
GPIO16_GSBI5_0
USB_ID
GPIO12_GSBI4_0
GND
Direction related
to LTE-NAD
Input
Output
Input
Output
Input Power
76
USB_VBUS
Input
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
GPIO11_GSBI3_3
GPIO10_GSBI3_2
GPIO9_GSBI3_1
GPIO8_GSBI3_0
GPIO6_ UIM2_CLK
GND
GPIO2_ UIM1_CLK
GPIO5_ UIM2_RST
GPIO7_ UIM2_DATA
GPIO4_ UIM2_DET
GND
HSIC_DATA
GND
HSIC_STROBE
GND
GPIO3_ UIM1_DATA
GPIO1_ UIM1_RST
GPIO78
GPIO79_ HSIC_RDY
GPIO85
GPIO86_
GPS_EXT_LNA_EN
GND
VREG_USB3_3V075
GND
VREG_MSME_1V8
GND
VREG_UIM2
VREG_SDC1_2V95
GND
VREG_UIM1
GND
GND
VMAIN
VMAIN
VMAIN
VMAIN
Output
Input
IN/OUT
IN/OUT
IN/OUT
Input Power
Output
IN/OUT
IN/OUT
IN/OUT
Input Power
IN/OUT
Input Power
IN/OUT
Input Power
Output
Output
IN/OUT
Output
Output
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
Comment
4 – Pin – UART Clear To Send 1
I²C - Clock
4 – Pin – UART Ready For Receive 1
Main ground connection
High – Speed USB Device for
communication
2 – Pin – UART TXD 2
2 – Pin – UART RXD 2
Main ground connection
SIM Card - Clock
Main ground connection, Corner pad
Connection to Ethernet Controller
Main ground connection
Connection to Ethernet Controller
Main ground connection
SIM Card – Data 1
SIM Card – Reset 1
Reset of Ethernet Controller
Time synchronization
IN/OUT
Input Power
Output Power
Input Power
Output Power
Input Power
Output Power
Output Power
Input Power
Output Power
Input Power
Input Power
Input Power
Input Power
Input Power
Input Power
Main ground connection
Output Power to USB
Main ground connection
Output Power
Main ground connection
Output Power to SIM Card 2
Output Power to SD Card 1
Main ground connection
Output Power to SIM Card 1
Main ground connection
Main ground connection
Main power
Main power
Main power
Main power
_______________________________________________________________________________________________________________ Seite 13
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
PIN
Signal
113
114
115
116
117
118
119
120
121
GND
GND
PON
HW-REV-RESISTOR
PM_GPIO3
GND
PM_MPP5
PM_MPP1
GND
Direction related
to LTE-NAD
Input Power
Input Power
Input
Output
IN/OUT
Input Power
Input
Input
Input Power
122
GPIO69
Output
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143 –
152
153
154 –
160
161
162 –
164
165
166
167 –
172
GPIO0_ UIM1_DET
GPIO77
GPIO65
GPIO61
PON_N
GND
GPIO68
GPIO51
GPIO54
GND
PM_MPP2
PM_GPIO2
PM_GPIO1
PM_GPIO6
GND
GPIO73
GND
GPIO48
GPIO49
GPIO53
Input
Output
Output
Input
Input
Input Power
Output
Input
Input
Input Power
Input
IN/OUT
IN/OUT
IN/OUT
Input Power
IN/OUT
Input Power
Input
Input
Input
GND
Input Power
Main ground connection
Main ground connection
Power On
Main ground connection
PM – ADC – channel
PM – ADC – channel
Main ground connection
Switch between main and back up
antenna
SIM Card – Detection 1
Reset signal of SDC2
NAD – Wake up
NAD – Update
Power On
Main ground connection
PS-3V8-Hold
BOOT_CONFIG3
BOOT_CONFIG0
Main ground connection
PM – ADC - channel
Main ground connection
Main ground connection, Corner pad
BOOT_CONFIG6
BOOT_CONFIG5
BOOT_CONFIG1
Main ground connection
Connection to the antenna switch
LGA_PRX_ANT
GND
Comment
Input Power
Main ground connection
Connection to the antenna connector
LGA_GPS_DRX_ANT
GND
Input Power
Main ground connection
LGA_DRX_ANT_IN
LGA_DRX_ANT_OUT
Input
Connection to the antenna switch
GND
Input Power
Main ground connection
_______________________________________________________________________________________________________________ Seite 14
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Note: Pins should be grounded when not used in design.
3.4 Supply Voltage
The external supply voltage is applied to LTE-NAD by 8 Pins on modules signal connectors.
PINs 109, 110, 111, 112 for VMAIN
PINs 107, 108, 113, 114 for the corresponding GND
Please note that there are further main ground connection that should be connected to ensure
proper NAD function.
TA = -40°C … +85°C
Absolute minimum/maximum supply voltages
Nominal supply voltage
Recommended supply voltage
Voltage drop @ GSM power burst (33dBm)
3.6V ~ 4.0V
3.8V
3.8V
<100mV
During Hi RF Power GSM bursts the power amplifier can draw peak currents > 2Amps at
VMAIN. The voltage drop during the GSM burst shall not exceed 100mV.
3.5 Power Consumption
TA = +25°C, VPH_PWR =3.8V
Voice
Voice
Voice
Voice
call
call
call
call
WCDMA
WCDMA
WCDMA
WCDMA
BC1
BC2
BC5
BC8
Voice call GSM850
Voice call GSM900
Voice call GSM1800
Voice call GSM1900
Standby current GSM
Standby current WCDMA
Standby current LTE
DRX = 5
DRX = 7
DRX = 7
Output Power
max. (typ. 23dBm)
~530mA
~570mA
~630mA
~580mA
Output Power
0 dBm
~145mA
~145mA
~140mA
~140mA
PCL 5 (typ. 32.5 dBm)
~260mA
~270mA
PCL 0 (typ.30.5dBm)
~165mA
~165mA
PCL 19 (typ. 5dBm)
~65mA
~65mA
PCL 15 (typ.0dBm)
~65mA
~65mA
Tbd mA
Tbd mA
_______________________________________________________________________________________________________________ Seite 15
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Output Power
Output Power
LTE data call B3
LTE data call B7
LTE data call B20
3.6 Transmitter
Tbd.
3.7 Receiver
Tbd.
3.8 Environmental Specification
3.8.1 Temperature Range
Range
Operating temp. range
Operating temp. range
-20°C … +65°C
-40°C … +85°C
Storage temp. range
-40°C … +85°C
Note 1
3GPP spec. conform
Operational
Performance might slightly
deviate from 3GPP spec.
Note 1: Due to temperature specification of the chipset, the temperature of the power manager and the
temperature of the modem chip shall not exceed +85°C.
_______________________________________________________________________________________________________________ Seite 16
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
4
Evaluation Kit
4.1 Overview
For the NAD V1140-xxx, there is an evaluation board available.
Features:
- On board 12V DC power supply (alternatively 3,8V DC direct connected, unbuffered).
- USB port type B
- SIM card tray
- 20 pin JTAG header for debugging
- 2 UART ports connected to DB9
- CODEC supported by I2S and I2C interfaces
Using the evaluation board with an external power supply
By default the module can be supplied by a switching regulator at 12V DC input voltage or by the module
VCC at 3.8V.
3.8V supply should be able to deliver 3.5A max. Sense contacts are for supplies which support the
corresponding feature.
Using the evaluation board with on board 3.8V regulator
For use at 3.8V simply disconnect the 12V supply and plug on 3.8V.
Note: Make sure that the external power supply is not generating spikes or
hazards higher than 4.0V. LTE-NAD Module gets damaged when spikes or
hazards above 4.0V are applied
RF Connector
For RF measurements use main antenna connector
_______________________________________________________________________________________________________________ Seite 17
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Figure 2 Evaluation Kit for V1140-xxx.
_______________________________________________________________________________________________________________ Seite 18
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Figure 3 Power supply for Evaluation Kit for V1140-xxx.
Figure 4 SIM card and USB interfaces for Evaluation Kit for V1140-xxx.
_______________________________________________________________________________________________________________ Seite 19
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Figure 5 RF interfaces for Evaluation Kit for V1140-xxx.
Figure 6 Loudspeaker and microphone interfaces for Evaluation Kit for V1140-101.
_______________________________________________________________________________________________________________ Seite 20
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
4.2 Firmware Update
For Firmware (FW) update the Windows software tool swupd.exe is available. To run a FW update
following preconditions should be fulfilled:
Evaluation board is power-on and connected to laptop or PC
Qualcomm HS-USB Diagnostics 9025 Driver, version 2.0.9.1d or higher, is installed
Virtual COM port of Qualcomm HS-USB Diagnostics 9025 is identified
Note: Please ensure to have a backup of your module configuration file
4.2.1 Identify Qualcomm Diagnostics Port Number
Please use the Windows Device Manager to identify virtual COM port number
Figure 7 Identify Virtual COM port number of Qualcomm HS-USB Diagnostics 9025 using Windows Device Manager – in provided
example COM5
4.2.2 Install and Run FW Executable
There is no dedicated software installation required. Please copy all files received with FW update to
folder of your choice and ensure that all components are available
Figure 8 Components of FW update tool
Important: Before starting FW update ensure to have backup QCN file of your evaluation board.
_______________________________________________________________________________________________________________ Seite 21
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
To start update process please run the batch file swupd_start.bat and enter Virtual COM port number
identified in previous step.
Figure 9 Complete FW update
A complete FW update will take about 2:30 minutes. Please note that there are other options to run FW
update. To learn more please run swupd.exe /h.
4.2.3 Known Issues
Sometimes a timeout occurs. Please simply re-run the batch file in that case.
Please inform us if you experience problems updating the FW on Evaluation Board.
Please check if access to Qualcomm HS-USB Diagnostics port is blocked by other program.
_______________________________________________________________________________________________________________ Seite 22
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
4.3 Windows 7 Driver Installation
4.3.1
Driver installation
The released 64-bit Windows 7 USB host driver package is Qualcomm’s HK11-NA430-7_1.00.22 or
higher revision, where 7_1.00.22 is the revision number.
Driver can be obtained from Qualcomm. Following the license conditions, peiker is not allowed to
distribute this driver.
Note: There could be certificates to be installed.
4.3.2
Available interfaces
The interfaces provided in Fig. 9 in Windows Device Manager will appear once
- the USB driver is installed properly,
- the USB cable connects EvalBoard and computer, and
- the Evaluation Board is powered-up.
Figure 10 Interfaces provided by Evaluation Board for OS Windows 7
In following chapters provide some information on how these interfaces could be used.
4.3.3
AT Command interface and PPP Dial-up Modem connection
AT commands are used to control to some extent the modem. To send AT commands to the Modem such
tools as PuTTY or similar are used.
To setup PuTTY the virtual COM port can be read from Modem property information – right click in
Device Manager the Modem string and select “Properties”. The assigned virtual COM port is shown in
“Modem” dialog box, see in Figure 11 – Port COM7.
_______________________________________________________________________________________________________________ Seite 23
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Figure 11 Modem Property dialog box
Figure 12 Virtual COM port and modem settings
Furthermore, it is recommended to add the APN string in Modem property box as shown in Figure 12.
Alternatively, the APN string can be set by AT command AT+CGDCONT=1,"IP","web.vodafone.de"
(Note: The latter is the special APN valid for Vodafone Germany only). Please check with your Provider
the correct APN string.
Figure 13 Enter the APN delivered by your MNO in Modem Property dialog
_______________________________________________________________________________________________________________ Seite 24
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Select in “Network and Sharing Center” of “Control Panel” the option “Set Up a Connection or
Network” and enter here the “Connect to the Internet” option. Follow the instructions to setup a new dialup connection.
Once the connection is setup, the Dial-up Connection is available under Network Connections. Using the
Windows context menu, the connection maybe activated or deactivated.
Figure 14 Dial-up Connection is available under Network Connections.
Note: Prior to use this connection, a valid APN for your Mobile Network Operator must be entered, see
explanation above.
LTE-NAD AT command set is provided in chapter 5 AT Command interface
4.3.4
RmNet NDIS connection as Network Interface Card
Figure 15 The USB driver provides a NIC (Network Interface Card).
Currently according to Qualcomm proprietary information on x86, x64/AMD64, and ARM (Win8 only,
for WoA/WoS) architectures following NDIS versions are supported (Source: Qualcomm Solution
00007808):





NDIS 5.1: Windows XP, Server 2003, CE
NDIS 5.2: Windows Server 2003 SP2
NDIS 6.0: Windows Vista
NDIS 6.1: Windows Vista SP1, Server 2008
NDIS 6.20: Windows 7, Server 2008 R2
Note: If NIC connection is not available please check with your Service Engineer if NV# 3534 is
properly set.
_______________________________________________________________________________________________________________ Seite 25
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Note: Especially for LTE the NIC interface provides much more data throughput as the PPP Dial-up
Modem connection.
4.3.5
Diagnostics interface
The Diagnostics Interface can be used with special Qualcomm Tools that are matter of dedicated license
agreement with Qualcomm. Therefore, there is no additional information provided in this document.
Note: Diagnostics Port is used for Firmware Updates as explained in chapter Firmware Update
4.3.6
NMEA GNSS interface
The virtual NMEA COM port provides NMEA information, delivered by build-in GNSS receiver of LTENAD Module.
LTE-NAD provides GPS and GLONASS location information. Please contact peiker for GALILEO
support.
AT Command Set
The modules supports standard AT command as listed below. Commands are compliant to 3GPP TS
27.007 and TS 27.005
Command
Description
AT+CMGF
AT+CSCA
AT+CMGS
AT+CGMI
AT+CGMM
AT+CGMR
AT+CGSN
Message Format
Service Centre Address
Send Message
Manufacturer Identification
Request model identification
Request revision identification
Request product serial number
Request international mobile subscriber
identification
Call mode
AT+CIMI
AT+CMOD
AT+CHUP
ATD
ATA
ATH
AT+CBST
AT+CEER
AT+CVHU
AT+CREG
AT+COPS
AT+CLCK
AT+CPWD
AT+CLIP
AT+CLIR
Comment
Only one Parameter is supported by the
device.
Hang up call
Initiate a CS or PS call or supplementary service
Answer incoming CS call command
Hangup CS call command
Select bearer service type
Extended error report
Voice hangup control
Network registration
PLMN selection
Facility lock
Change password
Calling line identification presentation
Calling line identification restriction
_______________________________________________________________________________________________________________ Seite 26
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Command
Description
AT+CCWA
AT+CHLD
AT+CUSD
AT+CLCC
AT+CPOL
AT+CPAS
AT+CFUN
AT+CPIN
AT+CSQ
AT+CMER
AT+CSIM
AT+CRSM
AT+CMEE
AT+CGDCONT
AT+CGEQREQ
AT-CGATT
AT+CGACT
AT+CGPADDR
AT+CGSMS
ATE
Call waiting
Call related supplementary services
Unstructured supplementary service data
List current calls
Preferred PLMN list
Phone active status
Set phone functionality
Enter PIN
Signal quality
Mobile termination event reporting
Generic SIM access
Restricted SIM access
Report mobile termination error
Define PDP context
Request 3G quality of service profile
PS attach or detach
PDP context activate or deactivate
Show PDP address
Select service for MO SMS messages
Character Echo ON/OFF
AT+CSMS
AT+CSMP
AT+CSDH
AT+CSCB
Check Message Service support
Set Text Mode Parameters
Show Text Mode Parameters
Select Cell Broadcast Message Types
Save Settings
AT+CSAS
AT+CRES
AT+CMGL
AT+CNMA
AT+CMGC
AT+CMMS
AT+ATV
AT+ATX
AT+CNMI
AT+CPMS
AT+CMGW
AT+CMSS
AT+CMGD
AT+CNUM
AT+CPBS
AT+CPBR
AT+CPBW
Comment
Restore Settings
Only one Parameter is supported by the
device.
Only one Parameter is supported by the
device.
List messages
New message acknowledgement
Send Command
More Messages to Send
DCE response format
Result code selection and call progress
monitoring control
New Message Indications to TE
Preferred Message Storage
Write Message to Memory
Send Message from Storage
Delete Messages
Get MSISDN
Select phonebook memory storage
Read phonebook entries
Writephonebook entry
_______________________________________________________________________________________________________________ Seite 27
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
6
Safety Recommendations according to EN60950-1
This device must be supplied by a limited power source according to EN 60950-1.
The clearance and creepage distances required by the end product must be withheld when the
module is installed.
The cooling of the end product shall not negatively be influenced by the installation of the
module.
_______________________________________________________________________________________________________________ Seite 28
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
7
List of Acronyms
3GPP
ADC
ADN
A-GPS
3 rd Generation Partnership Project
Analog Digital Converter
Abbreviated Dialing Number
Assisted GPS
AMR
Adaptive Multi Rate
AT
AWS
BER
CLIP
CLIR
CSD
DARP
DTMF
FDN
FTP
GSM
GPIO
GPRS
GPS
HSPA
HW
LED
MO
MT
OEM
PCB
PCM
PDU
PIN
RF
RoHs
UART
USB
USIM
UMTS
WCDMA
Attention Command
Advanced Wireless Services
Bit Error Rate
Calling Line Identification Presentation
Calling Line Identification Restriction
Circuit Switch Data
Downlink Advanced Receiver Performance
Dual Tone Multi Frequency
Fixed Dialing Number
File Transfer Protocol
Global System for Mobile communication
General Purpose Input Output
General Packet Radio Service
Global Positioning System
High Speed Uplink Packet Access
Hardware
Led Emitting Diode
Mobile Originated
Mobile Terminated
Original Equipment Manufacturer
Printed Circuit Board
Pulse Code Modulation
Protocol Data Unit
Personal Identification Number
Radio Frequency
Restriction of Hazardous Substances
Universal Asynchronous Receiver and Transmitter
Universal Serial Bus
Universal Subscriber Identity Module
Universal Mobile Telecommunications System
Wideband Code Division Multiple Access
_______________________________________________________________________________________________________________ Seite 29
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
8
Regulatory Certifications
In the context of sections 8.1 and 8.1.1, the terms “equipment” and “device” refer
equally to either V1140-100, V1140-101, V1140-103 or V1140-105.
In the context of section 8.2, the terms “apparatus”, “device” and “appareil” refer equally
to either V1140-101, V1140-103 or V1140-105.
8.1
USA (FCC)
This device complies with Part 15 of the FCC rules. Operation is subject to the
following two conditions:
(1) The device may not cause harmful interference, and
(2) The device must accept any interference received, including interference that
may cause undesired operation.
8.1.1
FCC Warnings and Notices
WARNING: The FCC requires the user to be notified that any changes or
modifications made to this device that are not expressly approved by peiker acustic
GmbH & Co. KG could void the user's authority to operate this equipment.
NOTICE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
_______________________________________________________________________________________________________________ Seite 30
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
8.2
Canada (IC)

This Class b digital apparatus comply with Canadian ICES-003.

Cet appareil numérique de la classe b est conforme à la norme NMB-003 du
Canada.

This device complies to Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including
interference that may cause undesired operation.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
meme si le brouillage est susceptible d'en compromettre le fonctionnement.
8.3
OEM Responsibilities
Antenna
The antenna gain, including cable loss and based on the capabilities of the
module’s transmitter mounted on the PCBs specified in the related FCC filings,
must not exceed 1,47dBd at 700 MHz & 850 MHz, 6dBi at 1700 MHz , 3.01dBi at
1900 MHz and 9,21 dBi at 2600 MHz for satisfying FCC RF exposure compliance.
The antenna gain, including cable loss and based on the capabilities of the
module’s transmitter in a stand-alone configuration, must not exceed 0,77dBd at
700 MHz & 850 MHz, 5dBi at 1700 MHz, 2.01dBi at 1900 MHz and 8,01 dBi at
2600 MHz for satisfying FCC RF exposure compliance.
The systems antenna(s) must be installed such that 20 cm is maintained between
the antenna(s) and the body of the user or nearby persons.
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter. The preceding statement must be included as a Caution
statement in OEM product manuals in order to alert users of FCC RF Exposure
compliance.
_______________________________________________________________________________________________________________ Seite 31
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Power Regulation
The host equipment must provide power regulation circuitry to ensure that the
module is supplied with stable 3.8VDC.
FCC Labeling
- The V1140-100 module is labeled with its own FCC ID Number. If the FCC ID is
not visible when the V1140-100 module is installed inside another device, then the
host device must contain the FCC ID number with the statement such as the
following: "Contains Transmitter Module FCC ID: QWY-V1140-100" or "Contains
FCC ID: QWY-V1140-100"
The V1140-101 module is labeled with its own FCC ID Number. If the FCC ID is
not visible when the V1140-101 module is installed inside another device, then the
host device must contain the FCC ID number with the statement such as the
following: "Contains Transmitter Module FCC ID: QWY-V1140-101" or "Contains
FCC ID: QWY-V1140-101"
The V1140-103 module is labeled with its own FCC ID Number. If the FCC ID is
not visible when the V1140-103 module is installed inside another device, then the
host device must contain the FCC ID number with the statement such as the
following: "Contains Transmitter Module FCC ID: QWY-V1140-103" or "Contains
FCC ID: QWY-V1140-103"
The V1140-105 module is labeled with its own FCC ID Number. If the FCC ID is
not visible when the V1140-105 module is installed inside another device, then the
host device must contain the FCC ID number with the statement such as the
following: "Contains Transmitter Module FCC ID: QWY-V1140-105" or "Contains
FCC ID: QWY-V1140-105"
IC Labeling
- The V1140-101 module is labeled with its own IC ID Number. If the IC ID is not
visible when the V1140-101 module is installed inside another device, then the
host device must contain the IC ID number with the statement such as the
following: "Contains Transmitter Module IC: 6588A-V1140101" or "Contains IC:
6588A-V1140101".
The V1140-103 module is labeled with its own IC ID Number. If the IC ID is not
visible when the V1140-103 module is installed inside another device, then the
host device must contain the IC ID number with the statement such as the
following: "Contains Transmitter Module IC: 6588A-V1140103" or "Contains IC:
6588A-V1140103".
The V1140-105 module is labeled with its own IC ID Number. If the IC ID is not
visible when the V1140-105 module is installed inside another device, then the
host device must contain the IC ID number with the statement such as the
_______________________________________________________________________________________________________________ Seite 32
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
following: "Contains Transmitter Module IC: 6588A-V1140105" or "Contains IC:
6588A-V1140105".
_______________________________________________________________________________________________________________ Seite 33
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 33
Language                        : en-US
Tagged PDF                      : Yes
Author                          : PEIKER acustic
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2014:09:03 11:59:44+02:00
Modify Date                     : 2014:09:03 11:59:44+02:00
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QWY-V1140-100