VEGA Americas PULS68 VEGAPULS 68 Radar Sensor User Manual Part 90
VEGA Americas Inc. VEGAPULS 68 Radar Sensor Part 90
Contents
- 1. Manual revised
- 2. Manual
Manual
Rhein Tech Laboratories 360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com APPENDIX E: MANUAL Please see the following pages. Client: Ohmart/VEGA Model: VEGAPULS 68 FCC ID: MOIPULS68 Standards: FCC 15.209/IC RSS-210 Report Number: 2004236 Operating Instructions VEGAPULS 68 4 ... 20 mA/HART WE'VE GOT ABILITY Contents Contents 1 About this document 1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 Target group . . . . . . . . . . . . . . . . . . . . . . 1.3 Symbolism used. . . . . . . . . . . . . . . . . . . . 2 For 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 your safety Authorised personnel . . . . . . . . . . . . . Appropriate use . . . . . . . . . . . . . . . . . Warning about misuse . . . . . . . . . . . . General safety instructions . . . . . . . . . CE conformity . . . . . . . . . . . . . . . . . . Compatibility acc. to NAMUR NE 53 . . FCC conformity (only for USA/Canada) Safety information for Ex areas . . . . . . Environmental instructions. . . . . . . . . . 3 Product description 3.1 Configuration . . . . . . . 3.2 Principle of operation . 3.3 Adjustment. . . . . . . . . 3.4 Storage and transport . .. .. .. .. .. .. .. .. .. .. 9 . . 10 . . 11 . . 11 4 Mounting 4.1 General instructions . . . . . . . . . . . . . . . . . 4.2 Mounting preparations, horn antenna . . . . . 4.3 Mounting preparations, parabolic antenna . 4.4 Mounting information . . . . . . . . . . . . . . . . 13 14 15 16 5 Connecting to power supply 5.1 Preparing the connection . . . . . . . . . . . . . 5.2 Connection procedure . . . . . . . . . . . . . . . 5.3 Wiring plans, single chamber housing . . . . 5.4 Wiring plans, double chamber housing . . . 5.5 Wiring plans, double chamber housing Exd. 22 23 24 26 28 VEGAPULS 68 - 4 ... 20 mA/HART 29261-EN-050202 Contents 6 Setup with the indicating and adjustment module PLICSCOM 6.1 Short description . . . . . . . . . . . . . . . . . 6.2 Installing the indicating and adjustment module PLICSCOM . . . . . . . . . . . . . . . 6.3 Adjustment system . . . . . . . . . . . . . . . . 6.4 Setup procedure . . . . . . . . . . . . . . . . . 6.5 Menu schematic. . . . . . . . . . . . . . . . . . . . 31 .. .. .. .. 31 33 34 39 7 Setup with PACTware™ 7.1 Connecting the PC . . . . . . . . . . . . . . . . . . 42 7.2 Parameter adjustment with PACTware™ . . 43 8 Maintenance and fault rectification 8.1 Maintenance . . . . . . . . . . . . . . 8.2 Fault rectification . . . . . . . . . . . 8.3 Exchanging the oscillator . . . . . 8.4 Instrument repair . . . . . . . . . . . .. .. .. .. 45 45 47 49 9 Dismounting 9.1 Dismounting procedure . . . . . . . . . . . . . . . 51 9.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . 51 29261-EN-050202 10 Supplement 10.1 Technical data . . . . . . . . . . . . . . . . . . . . . 52 10.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . 59 10.3 CE declaration of conformity . . . . . . . . . . . 70 VEGAPULS 68 - 4 ... 20 mA/HART About this document 1 About this document 1.1 Function This operating instructions manual has all the information you need for quick setup and safe operation of VEGAPULS 68. Please read this manual before you start setup. 1.2 Target group This operating instructions manual is directed to trained personnel. The contents of this manual should be made available to these personnel and put into practice by them. 1.3 Symbolism used Information, tip, note This symbol indicates helpful additional information. Caution, warning, danger This symbol informs you of a dangerous situation that could occur. Ignoring this cautionary note can impair the person and/or the instrument. Ex applications This symbol indicates special instructions for Ex applications. List The dot set in front indicates a list with no implied sequence. à Action This arrow indicates a single action. VEGAPULS 68 - 4 ... 20 mA/HART 29261-EN-050202 About this document Sequence Numbers set in front indicate successive steps in a procedure. 29261-EN-050202 VEGAPULS 68 - 4 ... 20 mA/HART For your safety 2 For your safety 2.1 Authorised personnel All operations described in this operating instructions manual must be carried out only by trained and specialist personnel authorised by the operator. For safety and warranty reasons, any internal work on the instruments must be carried out only by personnel authorised by the manufacturer. 2.2 Appropriate use VEGAPULS 68 is a sensor for continuous level measurement. 2.3 Warning about misuse Inappropriate or incorrect use of the instrument can give rise to application-specific hazards, e.g. vessel overfill or damage to system components through incorrect mounting or adjustment. 2.4 General safety instructions VEGAPULS 68 - 4 ... 20 mA/HART 29261-EN-050202 VEGAPULS 68 is a high-tech instrument requiring the strict observance of standard regulations and guidelines. The emitting frequencies of all VEGAPULS sensors are in the C or K-band range (depending on the instrument version). The low emitted powers are far below the internationally permitted limit values, in case of correct use, no health problems are expected. There are no restrictions in using the instrument also outside metallic, closed vessels. The user must take note of the safety instructions in this operating instructions manual, the country-specific installation standards (e.g. the VDE regulations in Germany) as well as all prevailing safety regulations and accident prevention rules. For your safety 2.5 CE conformity VEGAPULS 68 is in CE conformity with EMC (89/336/ EWG), fulfils the Namur recommendation NE 21 and is in CE conformity with NSR (73/23/EWG). Conformity has been judged acc. to the following standards: EMC: - Emission EN 61326: 1997 (class B) - Susceptibility EN 61326: 1997/A1: 1998 NSR: EN 61010-1: 2001. 2.6 Compatibility acc. to NAMUR NE 53 VEGAPULS 68 meets NAMUR recommendation NE 53. VEGA instruments are generally upward and downward compatible: sensor software of DTM VEGAPULS 68 HART, PA or FF l DTM VEGAPULS 68 for adjustment software PACTware™ l adjustment module PLICSCOM for sensor software The parameter adjustment of the basic sensor functions is independent of the software version. The available functions depend on the appropriate software version of the single components. The software version of VEGAPULS 68 can be determined as follows: via PACTware™ on the type label of the electronics l via the adjustment module PLICSCOM On our website www.vega.com you will find all software histories. Use the possibility and get registered for update information via e-mail. 29261-EN-050202 VEGAPULS 68 - 4 ... 20 mA/HART For your safety 2.7 FCC conformity (only for USA/Canada) VEGAPULS with all antenna versions are FCC approved. Modifications must be expressively agreed by VEGA, otherwise the operating licence acc. to FCC will expire. VEGAPULS 68 is in conformity with part 15 of the FCC regulations. Note the respective regulations for operation: The instrument must not cause any interfering emissions The instrument must be insensitive to interfering emissions, also to such causing unwanted operating conditions. 2.8 Safety information for Ex areas Please note the Ex-specific safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex-approved instruments. 2.9 Environmental instructions Protection of the environment is one of our most important duties. That is why we have introduced an environment management system with the goal of continuously improving company environmental protection. The environment management system is certified acc. to DIN EN ISO 14001. Please help us fulfil this obligation by observing the environmental instructions in this manual: Chapter "Storage and transport" Chapter "Disposal" 29261-EN-050202 VEGAPULS 68 - 4 ... 20 mA/HART Product description 3 Product description 3.1 Configuration Scope of delivery The scope of delivery encompasses: Components VEGAPULS 68 radar sensor documentation - this operating instructions manual - Ex-specific safety instructions (with Ex versions) and, if necessary, further certificates VEGAPULS 68 consists of the following components: l horn or parabolic antenna l process fitting (depending on the version flange or thread) l optionally available with swivelling holder (only with flange), rinsing air connection, reflux valve l housing with electronics l housing cover, optionally available with indicating/ adjustment module PLICSCOM 29261-EN-050202 The components are available in different versions. VEGAPULS 68 - 4 ... 20 mA/HART Product description Fig. 1: VEGAPULS 68 with horn antenna and swivelling holder Housing cover with integrated PLICSCOM (optional) Housing with electronics Swivelling holder with flange Horn antenna 3.2 Principle of operation Area of application VEGAPULS 68 is a radar sensor in K-band technology for continuous level measurement. A version of VEGAPULS 68 is available for the respective application: VEGAPULS 68 - 4 ... 20 mA/HART 29261-EN-050202 10 The version with horn antenna is particularly suitable for small silos and vessels for measurement of virtually all solids. The version with parabolic antenna is particularly suitable for large silos and vessels with up to 70 m (76 yd) measuring distance and for measurement of solids with small dielectric value. Product description Physical principle The antenna of the radar sensor emits short radar pulses with a duration of approx. 1 ns. These pulses are reflected by the product and received by the antenna as echoes. The running time of the radar pulses from emission to reception is proportional to the distance and hence to the level. The determined level is converted into an appropriate output signal and outputted as measured value. Power supply Two-wire electronics 4 ... 20 mA/HART for power supply and measured value transmission on the same cable. The power supply range can differ depending on the instrument version. The exact range is stated in the Technical data in the Supplement. 3.3 Adjustment VEGAPULS 68 can be adjusted with three different adjustment media: the indicating and adjustment module PLICSCOM an adjustment software acc. to FDT/DTM standard, e.g. PACTware™ and PC l a HART handheld The entered parameters are generally saved in VEGAPULS 68, optionally also in PLICSCOM or in PACTware™. 3.4 Storage and transport 29261-EN-050202 Packaging Your instrument was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a test acc. to EN 24180. The packaging of standard instruments consists of environment-friendly, recyclable cardboard. For special versions PE foam or PE foil can be also used. Dispose of the packaging material via specialised recycling companies. VEGAPULS 68 - 4 ... 20 mA/HART 11 Product description Storage and transport temperature Storage and transport temperature see Supplement, Technical data, Ambient conditions Relative humidity 20 ... 85 % 29261-EN-050202 12 VEGAPULS 68 - 4 ... 20 mA/HART Mounting 4 Mounting 4.1 General instructions Installation position Select an installation position you can easily reach for mounting and connecting as well as later retrofitting of an indicating and adjustment module PLICSCOM. The housing can be rotated by 330° without the use of any tools. You can also install the indicating and adjustment module PLICSCOM in four different positions (each displaced by 90°). Moisture Use the recommended cable (see chapter "Connecting to power supply") and tighten the cable entry. You can give your VEGAPULS 68 additional protection against moisture penetration by leading the connection cable downward in front of the cable entry. Rain and condensation water can thus drain off. This applies mainly to mounting outdoors, in areas where moisture is expected (e.g. by cleaning processes) or on cooled or heated vessels. Fig. 2: Measures against moisture penetration 29261-EN-050202 Measuring range The reference plane for the measuring range is the lower edge of the flange or the seal surface of the thread. Information: If the product reaches the antenna, buildup can form on it over a period of time and later cause measurement errors. VEGAPULS 68 - 4 ... 20 mA/HART 13 Mounting 100% 0% Fig. 3: Measuring range (operating range) and max. measuring distance Pressure full empty (max. measuring distance) Measuring range The process fitting must be sealed with gauge or low pressure in the vessel. Check before use, if the seal material is resistant against the measured product. The max. permissible pressure is stated in the Technical data in the Supplement or on the type label of the sensor. 4.2 Mounting preparations, horn antenna Information: This information applies only to special versions! VEGAPULS 68 is available in versions where the antenna has a bigger diameter than the process fitting (thread/flange). Therefore the antenna must be dismounted on the process fitting before mounting. Proceed as follows: 2 Remove the antenna (2) 14 VEGAPULS 68 - 4 ... 20 mA/HART 29261-EN-050202 1 Loosen the hexagon screws on the antenna socket (1) with an Allan key (size 3) Mounting 3 Insert the antenna from below into the vessel socket and secure it against falling off 4 Retighten the antenna with hexagon screws (1) to the antenna socket; torque max. 10 Nm (7.5 lbf ft) Fig. 4: Dismounting of the horn antenna Hexagon screws on the antenna socket Antenna 4.3 Mounting preparations, parabolic antenna Information: This information applies only to special versions! VEGAPULS 68 is available in versions where the antenna has a bigger diameter than the process fitting (thread/flange). Before starting to mount, the antenna must be dismounted on the flange. Proceed as follows: 1 Clamp VEGAPULS 68 with the flange, e.g. in a bench vice 29261-EN-050202 2 Hold the connection piece (3) with a wrench SW 22 on the flattenings 3 Unscrew the locknut (2) with SW 36 against the antenna 4 Unscrew the compression nut (1) with a wrench SW 41 against the antenna VEGAPULS 68 - 4 ... 20 mA/HART 15 Mounting 5 Remove the parabolic antenna (4) axially 6 Mount sensor flange to the adapter flange and clamp it 7 Check if there is a O-ring seal on the adapter and if it is not damaged. If necessary, replace it: Viton, article no. 2.28248, Kalrez 6375 article no. 2.27351. 8 Remount the parabolic antenna (4) 9 Tighten compression nut (3) with SW 41, torque max. 50 Nm. 10 Tighten locknut (2) with SW 36, torque max. 40 Nm. Fig. 5: Dismounting, parabolic antenna Compression nut Locknut Connection piece Parabolic antenna 4.4 Mounting information Horn and parabolic antenna The illustrations on the mounting instructions show a VEGAPULS 68 with horn antenna. The mounting instructions also apply to VEGAPULS 68 with parabolic antenna. 29261-EN-050202 16 VEGAPULS 68 - 4 ... 20 mA/HART Mounting Installation location When mounting the sensor, keep a distance of at least 200 mm (7.9 in) to the vessel wall. If the sensor is installed in the center of concave or arched vessel tops, multiple echoes can arise. These can, however, be faded out by an appropriate adjustment (see Setup). If this distance cannot be maintained, a false echo storage should be carried out during setup. This applies particularly if buildup on the vessel wall is expected. In this case, we recommend repeating the false echo storage later on with existing buildup. > 200 mm Fig. 6: Installation location Reference plane 29261-EN-050202 In vessels with conical bottom it can be advantageous to align the sensor to the center of the vessel, as measurement is then possible down to the lowest points of the vessel bottom. VEGAPULS 68 - 4 ... 20 mA/HART 17 Mounting Fig. 7: Vessel with conical bottom Inflowing material Do not mount the instruments in or above the filling stream. Make sure that you detect the product surface and not the inflowing product. Fig. 8: Inflowing material Mounting boss PreferablyVEGAPULS 68 should be mounted without socket flush to the vessel top. 29261-EN-050202 18 VEGAPULS 68 - 4 ... 20 mA/HART ca. 10 mm Mounting Fig. 9: Recommended socket mounting h max. If the reflective properties of the medium are good, you can mount VEGAPULS 68 on a socket piece. The socket end should be smooth and burr-free, if possible also rounded. Carry out a false echo storage. 1½" 50 mm/2" 80 mm/3" 100 mm/4" 150 mm/6" h max. 200 mm 250 mm 300 mm 500 mm 800 mm Fig. 10: Deviating socket dimensions In liquids, direct the sensor as close as vertical to the product surface to achieve optimum measurement results. 29261-EN-050202 Sensor orientation VEGAPULS 68 - 4 ... 20 mA/HART 19 Mounting Fig. 11: Orientation in liquids The version with swivelling holder ensures optimum orientation of the sensor to the solid cone. Loosen the screw on the swivelling holder with a flat wrench SW 13, direct the sensor and retighten the screw, torque max. 20 Nm. Vessel installations The radar sensor should be installed at a location where no installations cross the radar signals. Vessel installations such as, for example, ladders, limit switches, heating spirals, struts, etc. can cause false echoes superimposed on the useful echo. Make sure when planning your measuring location that the radar signals have "free access" to the measured product. In case of existing vessel installations, a false echo storage should be carried out during setup. If large vessel installations such as struts or supports cause false echoes, these can be attenuated through supplementary measures. Small, inclined sheet metal baffles above the installations scatter the radar signals and avoid a direct false echo reflection. 20 VEGAPULS 68 - 4 ... 20 mA/HART 29261-EN-050202 Fig. 12: Cover smooth profiles with deflectors Mounting Material heaps Large material heaps are detected with several instruments, which can be mounted on e.g. traverse cranes. For this type of application, it is best to orient the sensor toward the solid surface. 29261-EN-050202 Fig. 13: Radar sensors on traverse crane VEGAPULS 68 - 4 ... 20 mA/HART 21 Connecting to power supply 5 Connecting to power supply 5.1 Preparing the connection Note safety instructions Always observe the following safety instructions: Connect only in the complete absence of line voltage If overvoltages are expected, overvoltage arresters should be installed. Tip: We recommend VEGA overvoltage arresters ÜS-F-LB-I and ÜSB 62-36G.X. Take note of safety instructions for Ex applications In hazardous areas you should take note of the appropriate regulations, conformity and type approval certificates of the sensors and power supply units. Select power supply Power supply and current signal are transmitted via the same two-wire connection cable. The power supply range can differ depending on the instrument version. The exact range is stated in the Technical data in the Supplement. Provide a reliable separation between the supply circuit and the mains circuits acc. to DIN VDE 0106 part 101. The VEGA power supply units VEGATRENN 149AEx, VEGASTAB 690, VEGADIS 371 as well as all VEGAMETs meet this requirement. Bear in mind the following factors regarding supply voltage: Select connection cable VEGAPULS 68 is connected with standard two-wire cable without screen. An outer cable diameter of 5 ... 9 mm ensures the seal effect of the cable entry. If electromagnetic interference is expected, we recommend the use of screened cable. VEGAPULS 68 - 4 ... 20 mA/HART 29261-EN-050202 22 the reduction of the output voltage of the power supply unit under nominal load (with a sensor current of 20.5 mA or 22 mA in case of fault signal) the influence of additional instruments in the circuit (see load values in Technical data) Connecting to power supply Cable screening and grounding Connect the cable screen on both ends to ground potential. In the sensor, the screen must be connected directly to the internal ground terminal. The ground terminal outside on the housing must be connected to the potential equalisation (low impedance). If potential equalisation currents are expected, the connection on the evaluation side must be made via a ceramic capacitor (e.g. 1 nF, 1500 V). The low frequency potential equalisation currents are thus suppressed, but the protective effect against high frequency interference signals remains. Select connection cable for Ex applications Take note of the corresponding installation regulations for Ex applications. In particular, make sure that no potential equalisation currents flow over the cable screen. In case of grounding on both sides this can be achieved by the use of a capacitor or a separate potential equalisation. 5.2 Connection procedure Proceed as follows: 1 Unscrew the housing cover 2 If a PLICSCOM indicating and adjustment module is installed, remove it by turning it slightly to the left. 3 Loosen compression nut of the cable entry 4 Remove approx. 10 cm (4 in) of the cable mantle, strip approx. 1 cm (0.4 in) insulation from the ends of the individual wires 5 Insert the cable into the sensor through the cable entry 29261-EN-050202 6 Lift the opening levers of the terminals with a screwdriver (see following illustration) 7 Insert the wire ends into the open terminals according to the wiring plan 8 Press down the opening levers of the terminals, you will hear the terminal spring closing VEGAPULS 68 - 4 ... 20 mA/HART 23 Connecting to power supply 9 Check the hold of the wires in the terminals by lightly pulling on them 10 Connect the screen to the internal ground terminal and the external ground terminal to potential equalisation 11 Tighten the compression nut of the cable entry, the seal ring must completely encircle the cable 12 Screw the housing cover back on The electrical connection is finished. Fig. 14: Connection steps 6 and 7 5.3 Wiring plans, single chamber housing The following illustrations apply to the non-Ex as well as to the Ex ia version. 29261-EN-050202 24 VEGAPULS 68 - 4 ... 20 mA/HART Connecting to power supply Housing overview Fig. 15: Material versions, single chamber housing Plastic Aluminium Stainless steel Filter element for pressure compensation Electronics and connection compartment Display Com. 5 6 7 8 Fig. 16: Electronics and connection compartment, single chamber housing 29261-EN-050202 Plug connector for VEGACONNECT (I²C interface) Spring-loaded terminals for connection of the ext. indication VEGADIS 61 Ground terminal for connection of the cable screen Spring-loaded terminals for power supply and cable screen VEGAPULS 68 - 4 ... 20 mA/HART 25 Connecting to power supply Wiring plan Display Com. Fig. 17: Wiring plan, single chamber housing Power supply/Signal output 5.4 Wiring plans, double chamber housing The following illustrations apply to the non-Ex as well as to the Ex ia version. The Exd version is described in the next subchapter. Housing overview Fig. 18: Double chamber housing Housing cover, connection compartment Blind stopper or plug M12x1 for VEGADIS 61 (option) Housing cover, electronics compartment Filter element for pressure compensation Cable entry or plug 29261-EN-050202 26 VEGAPULS 68 - 4 ... 20 mA/HART Connecting to power supply Electronics compartment Display Com. 5 6 7 8 Fig. 19: Electronics compartment, double chamber housing Plug connector for VEGACONNECT (I²C interface) Internal connection cable to the connection compartment Terminals for VEGADIS 61 Display Connection compartment Com. Fig. 20: Connection compartment, double chamber housing Plug connector for VEGACONNECT (I²C interface) Ground terminal for connection of the cable screen Spring-loaded terminals for power supply and cable screen 29261-EN-050202 VEGAPULS 68 - 4 ... 20 mA/HART 27 Connecting to power supply Wiring plan Com. Fig. 21: Connection compartment, double chamber housing Power supply/Signal output 5.5 Wiring plans, double chamber housing Exd Housing overview Fig. 22: Double chamber housing Housing cover, connection compartment Blind stopper or plug M12x1 for VEGADIS 61 (option) Housing cover, electronics compartment Filter element for pressure compensation Cable entry or plug 29261-EN-050202 28 VEGAPULS 68 - 4 ... 20 mA/HART Connecting to power supply Electronics compartment Display Com. 5 6 7 8 Fig. 23: Electronics compartment, double chamber housing Plug connector for VEGACONNECT (I²C interface) Internal connection cable to the connection compartment Terminals for VEGADIS 61 Connection compartment 1 2 Fig. 24: Connection compartment, double chamber housing Exd Spring-loaded terminals for power supply and cable screen Ground terminal for connection of the cable screen 29261-EN-050202 VEGAPULS 68 - 4 ... 20 mA/HART 29 Connecting to power supply Wiring plan Fig. 25: Wiring plan, double chamber housing Exd Power supply/Signal output 29261-EN-050202 30 VEGAPULS 68 - 4 ... 20 mA/HART Setup with the indicating and adjustment module PLICSCOM 6 Setup with the indicating and adjustment module PLICSCOM 6.1 Short description Function/Configuration The indicating and adjustment module PLICSCOM is used for measured value display, adjustment and diagnosis. It can be mounted in the following housing versions and instruments: All sensors of the plics® instrument family, in the single as well as in the double chamber housing (optionally in the electronics or connection compartment) external indicating and adjustment unit VEGADIS 61 Note: You will find detailed information on the adjustment in the operating instructions manual of the indicating and adjustment module PLICSCOM. 6.2 Installing the indicating and adjustment module PLICSCOM Insert/remove PLICSCOM PLICSCOM can be inserted or removed at any time. An interruption of the power supply is not necessary. To install, proceed as follows: 1 Unscrew the housing cover 2 Place PLICSCOM in the desired position on the electronics (you can choose any one of four different positions - each displaced by 90°) 29261-EN-050202 3 Press PLICSCOM lightly onto the electronics and turn it to the right until it snaps in. 4 Screw housing cover with inspection window tightly back on Removal is carried out in reverse order. VEGAPULS 68 - 4 ... 20 mA/HART 31 Setup with the indicating and adjustment module PLICSCOM PLICSCOM is powered by the sensor, an additional connection is not necessary. Fig. 26: Installation of PLICSCOM Note: If you intend to retrofit VEGAPULS 68 with PLICSCOM for continuous measured value indication, a higher cover with an inspection glass is required. 29261-EN-050202 32 VEGAPULS 68 - 4 ... 20 mA/HART Setup with the indicating and adjustment module PLICSCOM 6.3 Adjustment system 1.1 Fig. 27: Indicating and adjustment elements Key functions LC display Indication of the menu item number Adjustment keys [OK] key: - move to the menu overview - confirm selected menu - edit parameter - save value [–>] key to select: - menu change - list entry - editing position [+] key: - modify value of a parameter [ESC] key: - interrupt input - jump to the next higher menu 29261-EN-050202 Adjustment system The sensor is adjusted via the four keys of the indicating and adjustment module PLICSCOM. The LC display indicates the individual menu items. The functions of the individual keys are shown in the above illustration. Approx. 10 minutes after the last pressing of a key, an automatic reset to measured value indication is trigger- VEGAPULS 68 - 4 ... 20 mA/HART 33 Setup with the indicating and adjustment module PLICSCOM ed. Any values not confirmed with [OK] will not be saved. 6.4 Setup procedure Switch on phase After VEGAPULS 68 is connected to power supply or after voltage recurrence, the instrument carries out a self-test for approx. 30 seconds. The following steps are carried out: internal check of the electronics indication of the instrument type, the firmware version as well as the sensor TAGs (sensor name) l Output signal jumps briefly (approx. 10 seconds) to the set interference current. Then the actual measured value is displayed and the corresponding current is transmitted to the cable1) Address setting HARTMultidrop In HART-Multidrop mode (several sensors on one input) the address must be set before continuing with the parameter adjustment. You will find a detailed description in the operating instructions manual of PLICSCOM or in the online help of PACTware™ or DTM. HART mode Standard Address 0 Parameter adjustment 1) 34 The values correspond to the actual level as well as to the settings already carried out, e.g. default setting. VEGAPULS 68 - 4 ... 20 mA/HART 29261-EN-050202 Because VEGAPULS 68 is a distance measuring instrument, the distance from the sensor to the product surface is measured. In order to have the actual level displayed, an allocation of the measured distance to the percentage height must be carried out. To make this adjustment, the full and empty distances in the vessel are entered. If these values are not known, it is also possible to carry out the adjustment with other distances, e.g. 10 % and 90 %. Starting point of these distance values is always the seal surface of the thread or flange. The actual level is then calculated on the basis of these Setup with the indicating and adjustment module PLICSCOM entered values. At the same time, the operating range of the sensor is limited from maximum range to the requested range. The real product level during this adjustment is not important, because the min./max. adjustment is always carried out without changing the product level. These settings can be made ahead of time without the instrument having to be installed. In the main menu item Basic adjustment, the individual submenu items should be selected one after the other provided with the correct parameter values. Start your parameter adjustment with the following menu items of the basic adjustment: Carrying out min. adjustment Proceed as follows: 1 Move from the measured value display to the main menu by pushing [OK]. Basic adjustment Display Diagnostics Service Info 2 Select the menu item Basic adjustment with [–>] and confirm with [OK]. Now the menu item min. adjustment is displayed. Min. adjustment 0.00 % 5.000 m(d) 4.000 m(d) 29261-EN-050202 3 Prepare the percentage value for editing with [OK] and set the cursor to the requested position with [–>]. Set the requested percentage value with [+] and save with [OK]. The cursor jumps now to the distance value. 4 Enter the appropriate distance value in m (corresponding to the percentage value) for the empty vessel (e.g. distance from the sensor to the vessel bottom). VEGAPULS 68 - 4 ... 20 mA/HART 35 Setup with the indicating and adjustment module PLICSCOM 5 Save the settings with [OK] and move to max. adjustment with [–>]. Carrying out max. adjustment Proceed as follows: Max. adjustment 100.00 % 1.000 m(d) 2.000 m(d) 1 Prepare the percentage value for editing with [OK] and set the cursor to the requested position with [–>]. Set the requested percentage value with [+] and save with [OK]. The cursor jumps now to the distance value. 2 Enter the appropriate distance value in m (corresponding to the percentage value) for the full vessel. Make sure that the max. level must be beneath the dead zone. 3 Save the settings with [OK] and move to the medium selection with [–>]. Medium selection Each product has different reflective properties. In solids, these are dust generation, material cones and additional echoes caused by the vessel wall. Due to the medium selection, the sensor is adapted in an optimum way to the product and the accuracy, particularly for products with bad reflective properties, is increased considerably. Medium Solid For solids you choose also Powder/Dust, Granular/ Pellets or Ballast/Pebbels. 36 VEGAPULS 68 - 4 ... 20 mA/HART 29261-EN-050202 In liquids, fluctuating surfaces and foam generation are further interfering factors. To adapt the sensor to the different conditions, a general selection is made in this menu item, i.e. Solid or Liquid. Setup with the indicating and adjustment module PLICSCOM Enter the requested parameter via the respective keys, save your settings and jump to the next menu item with the [–>] key. Vessel form Apart from the medium also the vessel form can influence the measurement. To adapt the sensor to these conditions, this menu item offers (depending on either liquid or solid is selected) different options. For Liquid these are Storage tank, Stilling tube, Open vessel or Stirred vessel, for Solid Silo or Bunker. Vessel form Silo Enter the requested parameter via the respective keys, save your settings and jump to the next menu item with the [–>] key. Damping To suppress fluctuation in the measured value display, e.g. by agitated product surfaces, an integration time can be set. This time can be between 0 and 999 seconds. Please note that the reaction time of the entire measurement will be longer and the sensor will react to quick changes of the measured value with a corresponding delay. In general, a time of a few seconds is sufficient to smooth the measured value display. Damping 0s Enter the requested parameter via the respective keys, save your settings and jump to the next menu item with the [–>] key. 29261-EN-050202 Linearization curve A linearization is necessary for all vessels in which the vessel volume does not increase linearly with the level e.g. in a cylindrical or spherical tank - and the indication or output of the volume is requested. Corresponding linearization curves are preprogrammed for these vessels. They represent the correlation between the level percentage and vessel volume. By activating the VEGAPULS 68 - 4 ... 20 mA/HART 37 Setup with the indicating and adjustment module PLICSCOM appropriate curve, the volume percentage of the vessel is displayed correctly. If the volume should not be displayed in percent but e.g. in l or kg, a scaling can be set in the menu item Display. Linearization curve linear Enter the requested parameter via the respective keys, save your settings and jump to the next menu item with the [–>] key. Sensor-TAG In this menu item you can enter an unambiguous designation for the sensor, e.g. the measurement loop name or the tank or product designation. In digital systems and in the documentation of larger plants, a unique designation should be entered for exact identification of individual measuring sites. Sensor-TAG Sensor With this menu item, the Basic adjustment is finished and you can now jump to the main menu with the [ESC] key. False echo storage High sockets or vessel installations, such as e.g. struts or agitators as well as buildup and weld joints on the vessel walls cause false reflections which influence the measurement. A false echo storage detects and marks these false echoes so that they are no longer taken into account for the level measurement. A false echo memory should be created with empty vessel so that all probably existing false reflections can be detected. False echo storage 29261-EN-050202 Change? Proceed as follows: 38 VEGAPULS 68 - 4 ... 20 mA/HART Setup with the indicating and adjustment module PLICSCOM 1 Move from the measured value display to the main menu by pushing [OK]. 2 Select the menu item Service with [–>] and confirm with [OK]. Now the menu item false echo storage is displayed. 3 Confirm False echo storage - Change now with [OK] and select in the below menu Create new. Enter the actual distance from the sensor to the product surface. All false echoes in this area are detected by the sensor and saved after confirming with [OK]. Note: Check the distance to the product surface as in case of a wrong (too big) setting, the real level will be saved as false echo. Hence the level can no longer be detected in this area. Additional adjustment and diagnosis options such as e. g. scaling, simulation or trend curve presentation are shown in the following menu schematic. You will find a detailed description of these menu items in the operating instructions manual of the indicating and adjustment module PLICSCOM. 29261-EN-050202 Optional settings VEGAPULS 68 - 4 ... 20 mA/HART 39 Setup with the indicating and adjustment module PLICSCOM 6.5 Menu schematic Basic adjustment Basic adjustment Display Diagnostics Service Info Min. adjustment 0.00 % 4.000 m(d) 3.000 m(d) 1.1 Damping 1.5 Max. adjustment 100.00 % 1.000 m(d) 2.000 m(d) 1.2 Linearization curve 1.6 0s Medium Solid 1.3 Vessel form 1.4 Silo Sensor-TAG linear 1.7 Sensor Display Basic adjustment Display Diagnostics Service Info Displayed value 2.1 scaled Display units 2.2 Volume m³ Scaling 2.3 0 % = 0.0 m³ 100 % = 100 m³ Diagnostics Basic adjustment Display Diagnostics Service Info Peak values Distance-min: 0.234m(d) Distance-max: 5.385m(d) 3.1 Meas. reliability 8db Sensor status OK 3.2 Choose curve echo curve 3.3 echo curve 3.4 Presentation of echo curve 29261-EN-050202 40 VEGAPULS 68 - 4 ... 20 mA/HART Setup with the indicating and adjustment module PLICSCOM Service Basic adjustment Display Diagnostics Service Info False echo storage 4.1 Addl. adjustments 4.2 none 4.5 Units of measurement Reset select? Copy sensor data 4.6 m(d) select? 4.9 PIN Copy sensor data? 4.3 Output mode 4-20 mA Failure mode <3.6 mA min. current 3.8 mA Change? Reset Current output Language Simulation 4.4 Simulation start? 4.7 Deutsch HART mode 4.8 Standard Address 0 4.10 Enable? Info Basic adjustment Display Diagnostics Service Info Sensor type VEGAPULS 6x 5.1 Date of manufacture 26. March 2004 Software version 3.12.00 5.2 Date of last change using PC 26. March 2004 5.3 Sensor details 5.4 Now display 29261-EN-050202 Serial number 12345678 VEGAPULS 68 - 4 ... 20 mA/HART 41 Setup with PACTware™ 7 Setup with PACTware™ 7.1 Connecting the PC Connecting the PC directly to the sensor VEGACONNECT 3 PACTwareTM/ >PA< Power supply Fig. 28: Connecting the PC directly to the sensor RS232 connection VEGAPULS 68 I²C adapter cable for VEGACONNECT 3 Necessary components: VEGAPULS 68 PC with PACTware™ and suitable VEGA-DTM VEGACONNECT 3 with I²C adapter cable (article no. 2.27323) power supply unit 29261-EN-050202 42 VEGAPULS 68 - 4 ... 20 mA/HART Setup with PACTware™ Connecting the PC to the signal cable Power supply PACTwareTM/ VEGACONNECT 3 Fig. 29: Connecting the PC to the signal cable RS232 connection VEGAPULS 68 HART adapter cable for VEGACONNECT 3 HART resistance 250 Ohm Necessary components: VEGAPULS 68 PC with PACTware™ and suitable VEGA-DTM VEGACONNECT 3 with HART adapter cable (art. no. 2.25397) HART resistance approx. 250 Ohm power supply unit Note: With power supply units with integrated HART resistance (internal resistance approx. 250 Ohm), an additional external resistance is not necessary (e.g. VEGATRENN 149A, VEGADIS 371, VEGAMET 381). In such cases, VEGACONNECT 3 can be connected in parallel to the 4 ... 20 mA cable. 29261-EN-050202 7.2 Parameter adjustment with PACTware™ Further setup steps are described in the operating instructions manual DTM Collection/PACTware attached to each CD and which can also be downloaded VEGAPULS 68 - 4 ... 20 mA/HART 43 Setup with PACTware™ from our homepage. A detailed description is available in the online help of PACTware™ and the VEGA-DTMs. Note: Keep in mind that for setup of VEGAPULS 68, DTMCollection 04/2004 or a newer version should be applied. All currently available VEGA-DTMs are provided in the DTM Collection on CD and can be bought from the responsible VEGA agency for a token fee. This CD includes also the up-to-date PACTware™ version. The basic version of this DTM Collection incl. PACTware™ is also available as a free-of-charge download from the Internet. 29261-EN-050202 44 VEGAPULS 68 - 4 ... 20 mA/HART Maintenance and fault rectification 8 Maintenance and fault rectification 8.1 Maintenance When used as directed in normal operation, VEGAPULS 68 is completely maintenance-free. 8.2 Fault rectification Causes of failure VEGAPULS 68 offers maximum reliability. Nevertheless, faults may occur during operation. These can have the following causes, e.g.: Sensor Process Power supply Signal processing. Fault rectification The first measures to be taken are to check the output signal and evaluate fault messages via the adjustment module PLICSCOM. The procedure is described below. Further comprehensive diagnostics can be carried out on a laptop with the software PACTware™ and the suitable DTM. In many cases, the reasons can be determined in this way and faults can be rectified. 24 hour service hotline Should these measures not be successful, please call in urgent cases the VEGA service hotline under the phone number +49 1805 858550. The hotline is available to you 7 days a week round-theclock. Since we offer this service world-wide, the support is only available in the English language. The service is free of charge, only the standard telephone costs will be charged. 29261-EN-050202 Checking the 4 ... 20 mA signal Connect a hand-held multimeter with a suitable measuring range acc. to the wiring plan. ? 4 ... 20 mA signal is not stable l level fluctuations à set integration time via PLICSCOM or PACTware™ VEGAPULS 68 - 4 ... 20 mA/HART 45 Maintenance and fault rectification ? 4 ... 20 mA signal missing l incorrect connection to power supply à check connection acc. to chapter "Connection procedure" and correct, if necessary, acc. to chapter "Wiring plans" l no power supply à check cables for line break, repair, if necessary l supply voltage too low or load resistance too high à check and adapt, if necessary ? Current signal greater than 22 mA or less than 3.6 mA l Electronics module defective à exchange instrument or return it for repair In Ex applications, the regulations for the wiring of intrinsically safe circuits must be observed. Fault messages via PLICSCOM ? E013 l no measured value available à sensor in boot phase à sensor does not find an echo, e.g. through incorrect installation or wrong parameter adjustment ? E017 l adjustment span too small à Carry out a fresh adjustment and increase the distance between min. and max. adjustment 29261-EN-050202 46 VEGAPULS 68 - 4 ... 20 mA/HART Maintenance and fault rectification ? E036 l no operable sensor software à carry out a software update or return instrument for repair ? E041 l hardware error, electronics defective à exchange instrument or return it for repair 8.3 Exchanging the oscillator Preparations If the electronics module is defective, it can be replaced by the user Oscillator PS-E.60SH. is suitable for VEGAPULS 68 – 4 ... 20 mA/HART. The following versions are available: PS-E.60SHX (without approvals) PS-E.60SHC (approvals XM, CX, CM, CK, CI, DX, DM, DK, DI; EX, GX, UX, UF acc. to VEGA product list) In Ex applications, only an oscillator with appropriate Ex approval must be used. If there is no oscillator available on site, it can be ordered from the responsible VEGA agency. The new oscillator must be according to the order data of the sensor. These can be loaded as follows: at the premises by VEGA on site by the user. 29261-EN-050202 Information: When loading on site, first of all the respective file must be downloaded from the Internet (see Setup). In both cases, the serial number of VEGAPULS 68 is necessary. The serial numbers are stated on the type label of VEGAPULS 68 or on the delivery note. VEGAPULS 68 - 4 ... 20 mA/HART 47 Maintenance and fault rectification Exchange Proceed as follows: 1 Switch off power supply 2 Unscrew the housing cover 3 Lift the opening levers of the terminals with a screwdriver 4 Pull the connection cables out of the terminals 5 Loosen the two screws with a Phillips screwdriver (size 1) Fig. 30: Loosen the screws Electronics module Screws (2 pcs.) 6 Pull the existing oscillator out by holding the opening levers. 7 Compare the new oscillator with the old one. The statements on the type label must correspond. This applies particularly to instruments in Ex areas. 8 Insert the oscillator 10 Insert the wire ends into the open terminals according to the wiring plan 48 VEGAPULS 68 - 4 ... 20 mA/HART 29261-EN-050202 9 Screw in and tighten the two screws with a Phillips screwdriver. Maintenance and fault rectification 11 Close the opening levers of the terminals, you will hear the terminal spring closing 12 Check the hold of the wires in the terminals by lightly pulling on them 13 Check the tightness of the cable entry. The seal ring must completely encircle the cable. 14 Screw the housing cover back on The electronics exchange is finished. As a rule, the exchange of the oscillator must be documented internally when used in Ex applications. Setup If the serial number of the oscillator is stated when ordering, VEGAPULS 68 is ready for operation directly after mounting the oscillator. If you are using an universal electronics from stock, you have to load the sensor data after mounting the oscillator.Use the item "serial number search" under www.vega.com. After having entered the serial number, the order data of the sensor will be displayed. Below the order data you will find "Sensor data for Service-DTM" as an XML file. Load this file to your PC and then into the sensor via PACTware™/Service DTM. After VEGAPULS 68 is ready for operation, settings carried out on site must be repeated. Tip: Use the copy function of the adjustment module PLICSCOM or the adjustment software PACTware™. 8.4 Instrument repair 29261-EN-050202 If it is necessary to repair VEGAPULS 68 please proceed as follows: You can download a return form (23 KB) from our Internet homepage www.vega.com under "Services > Downloads > Forms and Certificates > Repair form. VEGAPULS 68 - 4 ... 20 mA/HART 49 Maintenance and fault rectification By doing this you help us carry out the repair quickly and without having to call for additional information. Print and fill out one form per instrument Clean the instrument and pack it damage-proof Attach the completed form and possibly also a safety data sheet to the instrument Send the instrument to the respective address of your agency. In Germany to the VEGA headquarters in Schiltach. 29261-EN-050202 50 VEGAPULS 68 - 4 ... 20 mA/HART Dismounting 9 Dismounting 9.1 Dismounting procedure Warning: Before dismounting, be aware of dangerous process conditions such as e.g. pressure in the vessel, high temperatures, corrosive or toxic products etc. Take note of chapters "Mounting" and "Connecting to power supply" and carry out the listed steps in reverse order. 9.2 Disposal VEGAPULS 68 consists of materials which can be recycled by specialised recycling companies. We have purposely designed the electronic modules to be easily separable. Mark the instrument as scrap and dispose of it according to government regulations (electronic scrap ordinance, ...) Materials: see Technical data 29261-EN-050202 If you cannot dispose of the instrument properly, please contact us about disposal methods or return. VEGAPULS 68 - 4 ... 20 mA/HART 51 Supplement 10 Supplement 10.1 Technical data General data Materials, non-wetted parts - housing - seal ring between housing and housing cover - inspection window in housing cover for PLICSCOM - ground terminal Materials, wetted parts - process fitting - Antenna - seal, antenna system Weight with horn antenna - process fitting, thread - process fitting, flange - process fitting swivelling holder with flange Weight with parabolic antenna - process fitting, thread - process fitting, flange 52 stainless steel 1.4571/1.4435 thread G1½A and 1½ NPT, flanges DN 50 ... DN 200 and 2" ... 8": 316 L (stainless steel 1.4435) 316 L (stainless steel 1.4435), PTFE (TFM 1600 PTFE) Viton, Kalrez 2035, 6230, 6375, 6623 2.0 ... 2.8 kg (4.4 ... 6.2 lbs), depending on the thread size and housing 4.2 ... 15.4 kg (9.3 ... 34 lbs), depending on the flange size and housing 5.2 ... 16.4 kg (11.5 ... 35.2 lbs), depending on the flange size and housing 2.8 ... 3.6 kg (6.2 ... 13.7 lbs), depending on the thread size and housing 5.0 ... 16.2 kg (11 ... 35.7 lbs), depending on the flange size and housing 6.0 ... 17.2 kg (13.2 ... 37.9 lbs), depending on the flange size and housing VEGAPULS 68 - 4 ... 20 mA/HART 29261-EN-050202 - process fitting swivelling holder with flange plastic PBT (Polyester), Alu-die casting powder-coated, 316L (stainless steel 1.4435) NBR (stainless steel housing), silicone (Alu/plastic housing) Polycarbonate Supplement Output variable Output signal Resolution Fault signal Current limitation Load Integration time (63% of the input variable) Rise time Fulfilled Namur recommendation 4 ... 20 mA/HART 1.6 µA current output unchanged, 20.5 mA, 22 mA, < 3.6 mA (adjustable) 22 mA see load diagram in Power supply 0 ... 999 s, adjustable 150 ms (ti: 0 s, 0 ... 100 %) NE 43 Input variable Parameter Min. distance from antenna end max. measuring range distance between process fitting and product surface 400 mm (15.7 in) 60 m (197 ft), optionally 70 m (230 ft) Accuracy (similar to DIN EN 60770-1) Reference conditions acc. to DIN EN 61298-1 - temperature 18 ... 30°C (64 ... 86°F) - relative humidity 45 ... 75 % - pressure 860 ... 1060 mbar (86 ... 106 kPa or 12.5 ... 15.4 psi) 29261-EN-050202 Characteristics curve deviation and measurement characteristics2) Average temperature coefficient of 0.06 %/10 K the zero signal (temperature error) Resolution, general max. 1 mm Frequency K-band Interval > typ. 4 s Adjustment time3) 2) 3) VEGAPULS 68 - 4 ... 20 mA/HART Relating to the nominal range, incl. hysteresis and repeatability, determined acc. to the limit point method. Time to output the correct level (with max. 10 % deviation) after a sudden level change. 53 Supplement > 4 s (dependent on the parameter adjustment) Received average emitted power reaching an object directly in front of the antenna - distance 1 m 108 nW per cm² (108 x 10-9 W/cm²) - distance 5 m 4.3 nW per cm² (4,3 x 10-9 W/cm²) Beam angle with horn antenna, depending on the antenna diameter - ø 40 mm 22° - ø 48 mm 18° - ø 75 mm 10° - ø 95 mm 8° Beam angle with parabolic antenna Accuracy 3.5 ° see diagram 30 mm 15 mm 1,0 m 70 m -15 mm -30 mm Fig. 31: Accuracy VEGAPULS 68 Ambient conditions Ambient, storage and transport temperature - without PLICSCOM -40 ... +80°C (-40 ... +176°F) - with PLICSCOM -20 ... +70°C (-4 ... +158°F) 29261-EN-050202 54 VEGAPULS 68 - 4 ... 20 mA/HART Supplement Process conditions Vessel pressure horn antenna - without swivelling holder -1 ... 40 bar (-100 ... 4000 kPa or -14.5 ... 580) -1 ... 1 bar (-100 ... 100 kPa or -14.5 ... 14.5 psi) not sealing - with swivelling holder vessel pressure parabolic antenna - without swivelling holder - with swivelling holder -1 ... 6 bar (-100 ... 4000 kPa or -14.5 ... 87 psi) -1 ... 1 bar (-100 ... 100 kPa or -14.5 ... 14.5 psi) not sealing Process temperature (measured on the process fitting) depending on the seal of the antenna system - Viton -40 ... +130°C (-40 ... +266°F) - Viton with temperature adapter -40 ... +200°C (-40 ... +392°F) - Kalrez 2035, 6230, 6623 -15 ... +130°C (-5 ... +266°F) - Kalrez 2035, 6230 with tempe-15 ... +200°C (-5 ... +392°F) rature adapter - Kalrez 6375 -20 ... +130°C (-4 ... +266°F) - Kalrez 6375 with temperature -20 ... +200°C (-4 ... +392°F) adapter Vibration resistance mechanical vibrations with 4 g and 5 ... 100 Hz 4) 29261-EN-050202 Data on rinsing air connection Pressure max. 6 bar (87 psi) Thread G⅛A Check valve (option, attached with Ex version) - Material 316Ti (stainless steel 1.4571) - Seal Viton - for tube diameter 6 mm - opening pressure 0.5 bar (7.3 psi) - nominal pressure stage PN 250 4) VEGAPULS 68 - 4 ... 20 mA/HART Tested acc. to the regulations of German Lloyd, GL directive 2 55 Supplement Electromechanical data Cable entry/plug5) - single chamber housing or: 1x cable entry M20x1.5 (cable-ø 5 … 9 mm), 1x blind stopper M20x1.5 1 x closing cap ½ NPT, 1 x blind stopper ½ NPT or: - double chamber housing or: 1x plug (depending on the version), 1x blind stopper M20x1.5 1 x cable entry M20x1.5 (cable-ø 5 … 9 mm), 1 x blind stopper M20x1.5, plug M12x1 for VEGADIS 61 (option) 1x closing cap ½ NPT, 1x blind stopper ½ NPT, plug M12x1 for VEGADIS 61 (option) or: Spring-loaded terminals 1x plug (depending on the version), 1x blind stopper M20x1.5, plug M12x1 for VEGADIS 61 (option) for wire cross sections up to 2.5 mm² Indicating and adjustment module PLICSCOM Power supply and data transmission Indication Adjustment elements Protection - unassembled - mounted into the sensor without cover 56 IP 20 IP 40 depending on the version M12x1, acc. to DIN 43650, Harting, Amphenol-Tuchel, 7/8" FF VEGAPULS 68 - 4 ... 20 mA/HART 29261-EN-050202 5) through sensor via gold-plated sliding contacts (I²C bus) LC display in dot matrix 4 keys Supplement Materials - housing - inspection window ABS Polyester foil Power supply Supply voltage - non-Ex instrument - EEx ia instrument - EExd ia instrument 15 ... 36 V DC (14 ... 36 V with VEGAMET) 15 ... 30 V DC (14 ... 30 V with VEGAMET) 20 ... 36 V DC Permissible residual ripple - < 100 Hz - 100 Hz ... 10 kHz Uss < 1 V Uss < 10 mV Load see diagram Ω 1000 750 500 250 15 16 18 20 22 24 26 28 30 32 34 36 Fig. 32: Voltage diagram 1 HART load 2 Voltage limit EEx ia instrument 3 Voltage limit non-Ex instrument/Exd instrument 4 Supply voltage 29261-EN-050202 Electrical protective measures Protection Overvoltage category Protection class VEGAPULS 68 - 4 ... 20 mA/HART IP 66/IP 67 III II 57 Supplement Approvals6) ATEX 7) ATEX II 1G, 1/2G, 2G EEx ia IIC T5; ATEX II 1/2G, 2G EEx d ia IIC T5; ATEX II 1/2D IP6X T IEC EEx ia IIC T5 IEC 7) 58 Deviating data with Ex applications: see separate safety instructions depending on order specification VEGAPULS 68 - 4 ... 20 mA/HART 29261-EN-050202 6) Supplement 10.2 Dimensions Housing ~ 87mm (3 27/64") ø 84mm /16") ø 77mm ~ 116mm (4 9/16") ø 84mm (3 5/16") 114mm (4 31/64") ø 77mm (3 1/32") 117mm (4 39 120mm (4 23/32") ~ 69mm (2 23/32") 112mm (4 13/32") ~ 69mm (2 23/32") 20x1,5 ½ ½ NPT ½ NPT M20x1,5/ ½ NPT 29261-EN-050202 Fig. 33: Housing versions (with integrated PLICSCOM the height of the housing increases by 9 mm/0.35 in) 1 Plastic housing 2 Stainless steel housing 3 Aluminium double chamber housing 4 Aluminium housing VEGAPULS 68 - 4 ... 20 mA/HART 59 Supplement 118mm (4 41/64") 46mm (1 13/16") G1½A / 1½ NPT mm 1½" 100 ø40 2" 120 ø48 3" 216 ø75 4" 430 ø95 22mm (55/64") 22mm (55/64") 38mm (1 1/2") VEGAPULS 68 with horn antenna in threaded version 1½" 3 15/16" 4 23/32" 8 1/2" 16 59/64" 2" 3" 4" inch ø1 37/64" ø1 57/64" ø2 61/64" ø3 47/64" Fig. 34: VEGAPULS 68 with horn antenna in threaded version 1 Standard 2 with temperature adapter 29261-EN-050202 60 VEGAPULS 68 - 4 ... 20 mA/HART Supplement 118mm (4 41/64") 46mm (1 13/16") mm 1½" 100 ø40 2" 120 ø48 3" 216 ø75 4" 430 ø95 inch 1½" 3 15/16" 4 23/32" 8 1/2" 16 59/64" ø1 37/64" ø1 57/64" ø2 61/64" ø3 47/64" 2" 3" 4" G1½A / 1½ NPT 22mm (55/64") 38mm (1 1/2") 22mm (55/64") VEGAPULS 68 with horn antenna in threaded version with purging air connection 29261-EN-050202 Fig. 35: VEGAPULS 68 with horn antenna in threaded version with purging air connection and reflux valve (option) 1 Standard 2 with temperature adapter VEGAPULS 68 - 4 ... 20 mA/HART 61 Supplement 118mm (4 41/64") mm 1½" > 180 ø40 2" > 200 ø48 3" > 296 ø75 4" > 630 ø95 inch 1½" 7 3/32" 7 7/8" 11 21/32" 24 51/64" 2" 3" 4" ø1 37/64" ø1 57/64" ø2 61/64" ø3 47/64" G1½A / 1½ NPT 22mm (55/64") 38mm (1 1/2") 46mm (1 13/16") 22mm (55/64") VEGAPULS 68 with horn antenna in threaded version with purging air connection and antenna extension Fig. 36: VEGAPULS 68 with horn antenna in threaded version with purging air connection, antenna extension and reflux valve (option) 1 Standard 2 with temperature adapter 29261-EN-050202 62 VEGAPULS 68 - 4 ... 20 mA/HART Supplement 140mm (5 33/64") 60mm (2 23/64") VEGAPULS 68 with horn antenna in flange version mm inch DN 40 PN 40 150 18 110 4xø18 40 100 DN 40PN 40 5 29/32" 45/64" 4 21/64" 4xø45/64" 1 37/64" 3 15/16" DN 50 PN 40 165 20 125 4xø18 48 120 DN 50 PN 40 6 1/2" 25/32" 4 59/64" 4xø45/64" 1 57/64" 4 23/32" DN 80 PN 40 200 24 160 8xø18 75 216 DN 80 PN 40 7 7/8" 15/16" 6 19/64" 8xø45/64" 2 61/64" 25/32" 7 3/32" 3 47/64" 16 59/64" 9 29/64" 8xø55/64" DN 100 PN 16 220 20 180 8xø18 95 430 DN 100 PN 16 8 21/32" 285 22 240 8xø22 95 430 DN 150 PN 16 11 7/32" 55/64" 2" 150 lb 152,4 19,1 120,7 4xø19,1 48 120 2" 150 lb 6" 3/4" 3" 150 lb 190,5 23,9 152,4 4xø19,1 75 216 3" 150 lb 7 1/2" 15/16" 4" 150 lb 228,6 23,9 190,5 8xø19,1 95 430 4" 150 lb 9" 15/16" 6" 150 lb 279,4 25,4 241,3 8xø22,4 95 430 6" 150 lb 11" 1" 9 1/2" DN 150 PN 16 4 3/4" 8xø45/64" 8 1/2" 3 47/64" 16 59/64" 4xø3/4" 1 57/64" 4 23/32" 6" 4xø3/4" 2 61/64" 7 1/2" 8xø3/4" 3 47/64" 16 59/64" 8xø7/8" 3 47/64" 16 59/64" 8 1/2" 29261-EN-050202 Fig. 37: VEGAPULS 68 with horn antenna in flange version 1 Standard 2 with temperature adapter VEGAPULS 68 - 4 ... 20 mA/HART 63 Supplement VEGAPULS 68 with horn antenna and swivelling holder 40mm (1 37 /64 ") 1½" 100 ø40 2" 120 ø48 3" 216 ø75 4" 430 ø95 inch 1½" 2" 3" 3 15/16" 4 23/32" 8 1/2" 16 59/64" ø1 37/64" ø1 57/64" ø2 61/64" ø3 47/64" 4" 20mm ( 25/ 32 ") mm 20mm ( 25/ 32 ") 120m m (4 2 3/ 32 ") mm inch DN 50 / 2" 165 11,5 122,8 4xø19 DN 50 / 2" 6 1/2" 29/64" 4 53/64" 4xø3/4" DN 80 / 3" 200 11,5 156,2 4xø21 DN 80 / 3" 7 7/8" 29/64" 6 5/32" 4xø53/64" DN 100 / 4" 220 11,5 182,5 4xø22 DN 100 / 4" 8 21/32" 29/64" 7 3/16" 8xø55/64" Fig. 38: VEGAPULS 68 with horn antenna and swivelling holder 1 Standard 2 with temperature adapter 29261-EN-050202 64 VEGAPULS 68 - 4 ... 20 mA/HART Supplement 120m m (4 2 3/ 32 ") VEGAPULS 68 with horn antenna, swivelling holder and purging air connection 20mm ( 25/ 32 ") inch 1½" 100 ø40 1½" 3 15/16" 2" 120 ø48 2" 3" 216 ø75 3" 4" 430 ø95 4" ø1 37/64" 4 23/34" ø1 57/64" ø2 61/64" 8 1/2" 16 59/64" ø3 47/64" mm inch DN 50 / 2" 165 11,5 122,8 4xø19 DN 50 / 2" 6 1/2" 29/64" 4 53/64" 4xø3/4" 29/64" 6 5/32" 4xø53/64" 29/64" 7 3/16" 8xø55/64" DN 80 / 3" 200 11,5 156,2 4xø21 DN 80 / 3" 7 7/8" DN 100 / 4" 220 11,5 182,5 4xø22 DN 100 / 4" 8 21/32" 29261-EN-050202 Fig. 39: VEGAPULS 68 with horn antenna, swivelling holder, purging air connection and reflux valve (option) VEGAPULS 68 - 4 ... 20 mA/HART 65 Supplement 120m m (4 2 3/ 32 ") VEGAPULS 68 with horn antenna, swivelling holder, purging air connection and antenna extension 20mm ( 25/ 32 ") mm inch 1½" > 180 ø40 1½" 7 3/32" 2" > 200 ø48 3" > 296 ø75 2" 3" 4" > 630 ø95 4" ø1 37/64" 7 7/8" ø1 57/64" 11 21/32" ø2 61/64" 24 51/64" ø3 47/64" mm inch DN 50 / 2" 165 11,5 122,8 4xø19 DN 50 / 2" 6 1/2" 29/64" 4 53/64" 4xø3/4" DN 80 / 3" 200 11,5 156,2 4xø21 DN 80 / 3" 7 7/8" 29/64" 6 5/32" 4xø53/64" DN 100 / 4" 220 11,5 182,5 4xø22 DN 100 / 4" 8 21/32" 29/64" 7 3/16" 8xø55/64" Fig. 40: VEGAPULS 68 with horn antenna, swivelling holder, purging air connection, antenna extension and reflux valve (option) 29261-EN-050202 66 VEGAPULS 68 - 4 ... 20 mA/HART Supplement 128mm (5 3/64") G1½A / 1½ NPT 118mm (4 41/64") 46mm (1 13/16") 22mm (55/64") 38mm (1 1/2") 22mm (55/64") VEGAPULS 68 with parabolic antenna in threaded version ø 243mm (9 9/16") 29261-EN-050202 Fig. 41: VEGAPULS 68 with parabolic antenna in threaded version 1 Standard 2 with temperature adapter VEGAPULS 68 - 4 ... 20 mA/HART 67 Supplement VEGAPULS 68 with parabolic antenna in flange version 140mm (5 33/64") 60mm (2 23/64") 128mm (5 3/64") ø 243mm (9 9/16") mm inch DN 40 PN 40 150 18 110 4xø18 DN 40PN 40 5 29/32" 45/64" DN 50 PN 40 165 20 125 4xø18 DN 50 PN 40 6 1/2" 25/32" 4 59/64" 4xø45/64" DN 80 PN 40 200 24 160 8xø18 DN 80 PN 40 7 7/8" 15/16" 6 19/64" 8xø45/64" DN 100 PN 16 220 20 180 8xø18 DN 100 PN 16 8 21/32" 25/32" 7 3/32" DN 150 PN 16 285 22 240 8xø22 DN 150 PN 16 11 7/32" 55/64" 9 29/64" 8xø55/64" 4 3/4" 4xø3/4" 4xø3/4" 4 21/64" 4xø45/64" 8xø45/64" 2" 150 lb 152,4 19,1 120,7 4xø19,1 2" 150 lb 6" 3/4" 3" 150 lb 190,5 23,9 152,4 4xø19,1 3" 150 lb 7 1/2" 15/16" 6" 4" 150 lb 228,6 23,9 190,5 8xø19,1 4" 150 lb 9" 15/16" 7 1/2" 8xø3/4" 6" 150 lb 279,4 25,4 241,3 8xø22,4 6" 150 lb 11" 1" 9 1/2" 8xø7/8" Fig. 42: VEGAPULS 68 with parabolic antenna in flange version 1 Standard 2 with temperature adapter 29261-EN-050202 68 VEGAPULS 68 - 4 ... 20 mA/HART Supplement VEGAPULS 68 with parabolic antenna and swivelling holder 40mm (1 37 /64 ") 140m m (5 3 3/ 64 ") 120m m (4 2 3/ 32 ") ø 243 mm (9 9/ 16 ") mm inch DN 50 / 2" 165 11,5 122,8 4xø19 DN 50 / 2" 6 1/2" 29/64" 4 53/64" 4xø3/4" 7 7/8" DN 80 / 3" 200 11,5 156,2 4xø21 DN 80 / 3" DN 100 / 4" 220 11,5 182,5 4xø22 DN 100 / 4" 8 21/32" 29/64" 6 5/32" 4xø53/64" 29/64" 7 3/16" 8xø55/64" 29261-EN-050202 Fig. 43: VEGAPULS 68 with parabolic antenna and swivelling holder 1 Standard 2 with temperature adapter VEGAPULS 68 - 4 ... 20 mA/HART 69 10.3 CE declaration of conformity 29261-EN-050202 Fig. 44: CE declaration of conformity 70 VEGAPULS 68 - 4 ... 20 mA/HART 29261-EN-050202 VEGAPULS 68 - 4 ... 20 mA/HART 71 VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info@de.vega.com www.vega.com ISO 9001 All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing. Technical data subject to alterations 29261-EN-050202
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Modify Date : 2005:03:01 17:44:57-07:00 Create Date : 2005:03:01 17:44:27-07:00 Title : Part 90 Author : Dbaltzell Creator : Microsoft Word 10.0 Producer : Acrobat Distiller 4.05 for Windows Page Count : 73EXIF Metadata provided by EXIF.tools