VELUX America 836406 RF Interface and Beacon User Manual

VELUX America Inc. RF Interface and Beacon Users Manual

Users Manual

VAS 452421-2010-03Directions for useKLF 100ENGLISH: User manualESPAÑOL: Manual de usarioFRANÇAIS : Notice d'utilisationJAPANESE:
2   VELUX VELUX   3EnglishUser manual  x-xEspañolManual del usuario  x-xFrançais Notice d'utilisation  x-xJapaneseUser manual  x-x
4   VELUX ENGLISH VELUX   5ENGLISHImportant information  6-8Getting startedFitting  10Initial set-up  11Guide to quick standard set-up   12Example of typical use of the interface/repeater unit   13Interface/repeater unit function and connection  14-15SettingsChannels  16-19- Set channel  16- Block channel  17- Permanent blocking  18-19Setting of position  20-21- Position UP  21- Position DOWN  21System settingsRegister products  22-25- From a remote control  23- From a new product  24-25Select products  26-27Security key  28-29Copy system  30-31Signal mode  32-33Function as repeater unit     34-35Intelligent building installations  36Contents
ENGLISH ENGLISH 76   VELUX VELUX   7products connected to it (including battery backup KLB, if installed) and ensure that it cannot be reconnected unintentionally during this time.•   The product requires a minimal amount of maintenance. The surface may be cleaned with a soft, damp cloth using a small amout of household cleaner diluted in water.•   If main power supply cable is damaged, it must be replaced by qualified electrical installer in accordance with all local codes, ordinances, rules and regulations.•   If you have any technical questions, please contact VELUX.Installation•   The interface/repeater unit is for indoor use only.•   Installation in rooms with a high level of humidity and with hidden wiring must comply with relevant regulations (contact a qualified electrician if necessary).Function•   Check that the interface/repeater unit  can operate the relevant products from the chosen position before final fixing.•   If a skylight has been opened manually, it cannot be activated via the inter-face/repeater unit .•   In case of snow and/or ice, the automatic operation of certain products may be blocked.•   The entries in the interface/repeater unit  draw 5-10 mA at approx 10 V d.c. and must be connected to potential free contacts.•   Avoid frequent activation of the motors in the system from automatic sys-tems (eg IBI systems) as this will reduce the service life of the motors.•   The interface/repeater unit can be used as a repeater that extends the operation range of remote controls in the system.Product•   The interface/repeater unit is used when products are to be controlled with external control devices that are not compatible.IMPORTANT INFORMATION AND WARNINGSWARNING - TO REDUCE THE RISK OF SEVERE INJURY OR DEATH:Safety•   Read instructions carefully before installing and operating. •   Please keep instructions for future reference and hand them over to any new user.•   Never let children operate or play with the system. The remote control should be kept out of reach of children at a minimum height of 5 feet.•   The product must not be put into operation until it has been fitted accor-ding to these in-structions.•   Before operating ensure that the product can be and is operated without risk of damage to property or injury to people or animals.•   If repair and adjustment work is needed, disconnect from the main power supply and ensure that it cannot be reconnected unintentionally.•   The interface/repeater unit must not be covered (maximum casing tempe-rature: 104°F/40°C).•   This product has been designed for use with genuine VELUX products. Connection to or use with other products may cause damage, malfunction or injury.•   The interface/repeater unit has a Class 2 Low Voltage output (19-24 V d.c.).•   The power supply cable is equipped with a polarized plug. Do not change the plug.•   Disconnect from the main power supply before carrying out any mainte-nance, repair, adjustment or service work to the interface/repeater unit or Important information
8   VELUX ENGLISH VELUX   9ENGLISH•   The interface/repeater unit has a built-in RF (radio frequency) unit and will not be operative if placed in a metal cabinet.•   Electrical products must be disposed of in conformity with all local codes, ordinances, rules and regulations for electronic waste and not with house-hold waste.•   Used remote control batteries have to be disposed of in conformity with the relevant environmental regulations and ordinances.•   The packaging can be disposed of with usual household waste.•   Radio frequency band: 2.4 GHz.•   Radio frequency range: 110 yeards (100 m) free field. Depending on building construction, the indoor range is approx 30 ft (10 m). However, construc-tions with reinforced concrete, metal ceilings and plaster walls with steel members may reduce the range.Maintenance and service•   Spare parts are available through VELUX. Please provide information from the data plate. Important information
10   VELUX ENGLISH VELUX   11ENGLISHBackBackEnter Back      Dansk English DeutschEnter Back      Dansk English DeutschEnter Back     InterfaceInterface/repeater unitReset systemFitting1   Remove cover.2  Decide position of interface/repeater.  Note: Check that the interface/re-peater unit can operate the relevant products from the chosen position before final fixing.3  Connect interface/repeater unit to power supply. Do not replace cover until the entire installation process is completed.   The display appears automatically when the mains power is switched on.    After a short time menu item  is displayed.  Language1   Press     to highlight your language.Press   "Enter" to confirm your choice.2  The display shows that the language has been saved. After a short time menu item   is displayed.  Function   The interface/repeater unit is used when products are to be controlled with external control devices that are not compatible, eg intelligent building installations, sensors and standard wall switches.1   Press     to highlight "Interface/repeater unit".Press   "Enter" to confirm your choice.2  The display shows that the function has been saved. After a short time menu item   is displayed.   Note: "Repeater" is used for extending the operation range of remote controls in the system, see section  Function as repeater.   "Reset system" is used for deleting all settings and reset-ting the interface to its factory setting.Initial set-up
12   VELUX ENGLISH VELUX   13ENGLISHC˚F~74 °F 72 °F~70 °FEnter Back      XXXXXXX XXXXXXXGuide to quick standard set-upMenu items   to  These instructions refer to the menu items   to  . These menu items are shown automatically and in alphabetical order in the display, as the interface is installed.In many cases the interface/repeater unit factory set-tings are sucient and the interface/repeater unit can be used without further settings being programmed. When using the factory settings, first confirm the settings in menu items  , ,  ,   and  (described on pages 16-21).Then continue in menu item , submenu "Register pro-ducts" (described on pages 22-25) and submenu "Select products" (described on pages 26-27). It is not necessary to go through the other submenus in menu item .The interface is now ready for use.Thermostatic control of a VELUX skylight by a compa-tible thermostat A thermostat can be used to control automatic opening and closing of skylight(s) depending on the temperature. A typical thermostat works by means of a potential free change-over contact that switches between two positions depending on the ambient temperature. The illustration shows how to connect the potential free change-over contact to the inter-face/repeater unit.A thermostat set to 72 °F will typically change position (ie open the skylight(s)) when the tem-perature rises above 74°F, and switch back (ie close the skylight(s)) when the temperature again has fallen below 70 °F.The skylight(s) can be operated with the remote control at any time. Example of typical use of the interface/repeater unit
14   VELUX ENGLISH VELUX   15ENGLISHCCCCC Interface/repeater unit function and connectionThe interface/repeater unit is used when products are to be controlled by external control devices.Individual control of a product or a product group requires one interface/repeater unit per product or product group.The entries in the interface/repeater unit must be connec-ted to control devices with potential free contacts. When the potential free contact is activated, the interface/repeater unit sends an RF command to the products to be operated. It is possible to operate a single product or a group of products.Function of entriesOPEN/UP/ON is controlled by connecting C and   (2 core wire required).CLOSE/DOWN/OFF is controlled by connecting C and   (2 core wire required).STOP is controlled by connecting C with both   and   (3 core wire required).Note: Alternatively, a single contact can control both ,   and STOP, see section Signal mode.Connection to entriesA single contact can be used for running products either up or down.A set of two contacts can be used for running products both up and down with variable stops.A change-over contact can also be used for running pro-ducts both up and down but stops are not possible.Contact requirementsPotential free contacts with a maximum resistance of 100 Ω can be used. A current of 5-10 mA at approx 10 V d.c. runs through the contact. Contacts with a pulse signal can also be used if the dura-tion of the pulse is longer than 100 ms.Note: The operation of the interface/repeater unit can only be stopped by switching o the mains power.
16   VELUX ENGLISH VELUX   17ENGLISHBackBackEnter Back      Channel 6 Channel 7Edit Back      Channel 5 Channel 6Enter Back      SelectSaveEdit Back      Channel 5 Channel 6Enter Back      Deselect SaveChannels  Set channel    The system can send and receive commands on eight channels.   0 Personal safety  1  Product safety  2 Operation - high  3 Operation - normal  4 Automatic - 1  5 Automatic - 2  6 Automatic - 3  7  Automatic - 4   A VELUX remote control sends on channel 3. Channels 4 to 7 are intended for automatic functions.   The interface/repeater unit can send on one channel only and it is recommended to choose channel 7.1  Press     to choose channel.  Press   "Enter" to confirm your choice.2  The display shows that the chosen channel has been saved. After a short time menu item   is displayed.  Block channel   You can block commands from other interfaces/repea-ters or remote controls for 30 minutes from the time of sending the command from them. Each channel (3-7) must be blocked individually. In this way you can give some commands priority to others. See the example on page 17.1   Press     to highlight the channel to be blocked.Press   "Edit" to confirm that the channel in question is to be edited. 2  Press     to highlight "Select".Press   "Enter" to confirm your choice.3  The blocked channel has been ticked. Repeat items 1-2 to block additional channels if required.  Press   "Edit" to undo or save the settings.4  Press     to highlight "Save". Press   "Enter" to confirm your choice.5  The display shows that the channel(s) has/have been blocked. After a short time menu item   is displayed.
18   VELUX ENGLISH VELUX   19ENGLISHBackEnter Back      Off OnBackChannels  Permanent blocking   The interface/repeater unit can keep blocking the chosen channels for longer than 30 minutes. In this way, both external control devices with a pulse signal and ordinary control devices such as a standard wall switch can be used for blocking other commands.  1   Press     to highlight "On". Press   "Enter" to confirm your choice.2  The display shows that the function has been saved. After a short time menu item   is displayed.   Note: The blocking can be cancelled by simultaneously activating entry   and entry   from the external control device.    The blocking can also be cancelled temporarily by pressing  "Menu" on the display of the interface. The next time the entries are activated, the chosen channels are blocked again.Example of blocking channelsBlocking is used for blocking the commands of other control devices. For instance you may want to close the skylights when leaving the house. In this case, you can use a key switch that transmits a signal when you turn the key.If you set the interface/repeater unit to send on channel 7 and permanently block all other channels (4-6), the skylights will be closed when you lock the door.Note: Many alarm systems with integrated locking signal in the keypad can be used for activating the entries in the interface/repeater unit and therefore for blocking the operation of products in the system.
20   VELUX ENGLISH VELUX   21ENGLISHC Enter Back        90 % 100 % ManualEnter Back      BackEnter Back      100 %  90 %   80 %BackSetting of position  Positions UP and DOWN Setting of position is used to run products to a position between 0% and 100% at intervals of 10%. As default (factory setting) the products will travel to maximum top or bottom position.Position tableEntryDefault 0% 100%Blinds and shades Up DownSkylight Open ClosedThe position indication for VELUX products corresponds to the display information on a VELUX remote control. This applies to all product types except Skylight. You are therefore recommended to use the position table when setting the position. Always check the position settings when the installation of the interface/repeater unit has been completed.Note: You can also choose manual operation. In this case, the products will only be activated as long as the external control device is active.  Position UP1   Press     to choose the required position.Press   "Enter" to confirm your choice.2  The display shows that the position has been saved. After a short time menu item   is displayed.  Position DOWN1   Press     to choose the required position.Press   "Enter" to confirm your choice.2  The display shows that the position has been saved. After a short time menu item   is displayed.
22   VELUX ENGLISH VELUX   23ENGLISHBAEnter BackP1 P2MenuLocateP1 P2Enter Back        Register products  Select products Security keyBackBackRegister productCopy systemSecurity keyCongureSystem settings Register productsThe products must be registered in the interface/repeater unit to be operational.The interface/repeater unit can register:-  VELUX remote control KLR 100 (page ??)-  Control keypad KLI 110 (page ??)-  Directly from a new product (page ??)The registration takes place in 2 steps. Step 2 must be completed within two minutes after implementing step 1, so please read steps 1-2 before proceeding. Registration from a remote controlIf you have a VELUX remote control, you can copy the registered products from the remote control to the inter-face/repeater unit. Note: All products can be copied to the interface/repea-ter unit, but Groups, Zones and program functions cannot. The products to be operated through the interface/repea-ter unit are to be chosen in submenu "Select products".The example shows how to copy from a VELUX remote control B to interface/repeater unit A. Step 1: Remote control B1  Press   "Menu".2  Select the submenu:3   Press   to highlight "Copy system".Press   "Enter" to confirm your choice.  Step 2: Interface/repeater unit A4  Menu item   is highlighted.  Press     to highlight "Register products".Press   "Enter" to confirm your choice.5   Automatic registration is running. Please wait. The regis-tration can take up to one minute.6   The display shows that the new product(s) has/have been registered.
24   VELUX ENGLISH VELUX   25ENGLISHSystem settingsAEnter Back        Register products  Select products Security keyBackBackBAEnter Back        Register products  Select products Security keyBackBack    Registration from a new product  New products can be registered directly in the interface/repeater unit .   The example shows how to prepare VELUX products for registration. Step 1: Product B1   Switch o mains power to the product for at least one minute and subsequently switch on again.  Note: For other types of products, please refer to the ins-tructions provided with the product in question to execute step 1. Step 2: Interface/repeater unit A 2  Menu item   is highlighted.  Press     to highlight "Register products".Press   "Enter" to confirm your choice.3  Automatic registration is running. Please wait. The regis-tration can take up to two minutes.4  The display shows that the new product(s) has/have been registered. Step 1:KLI 110  Transmit system from KLI by pressing the "PRG" button for 3-4 seconds. LED flashes green slowly. Step 2: Interface/repeater unit A1  Menu item   is highlighted.  Press     to highlight "Register products".Press   "Enter" to confirm your choice.2  Automatic registration is running. Please wait. The regis-tration can take up to two minutes.3  The display shows that the new product(s) has/have been registered.  Connection to entries   A single contact can be used for running products either up or down. A set of two contacts can be used for running products both up and down with variable stops.   A change-over contact can also be used for running pro-ducts both up and down but stops are not possible.   Contact requirements   Dry contacts with a maximum resistance of 100 Ù can be used. A current of 5-10 mA at approx 10 V d.c. runs through the contact.   Contacts with a pulse signal can also be used if the dura-tion of the pulse is longer than 100 ms.  Note: The operation of the interface/repeater unit can only be stopped by switching o the mains power.
26   VELUX ENGLISH VELUX   27ENGLISHSelect product Identify product Save listEnter BackCreate list Undo list Identify productsEnter BackNo. 1 No. 2 No. 3Edit BackNo. 1 No. 2 No. 3Edit BackEnter BackCreate listUndo list Identify productsEnter Back        Register products Select products Security keyNo. 1No. 2No. 3Edit BackSelect productIdentify product Save listEnter BackSystem settings  Select products  The products to be controlled via the interface must now be selected.  The example shows how to select products from a VELUX remote control in which Rooms have been created.1   Press     to highlight "Select products". Press   "Enter" to confirm your choice.2  Press     to highlight "Create list".Press   "Enter" to confirm your choice.  The display shows a list of all registered products. 3  Press     to highlight the product to be edited. Press   "Edit" to confirm that the product in question is to be edited.4  Press     to highlight "Select product".Press   "Enter" to confirm your choice.  Note: The individual product can be identified by highlighting "Identify product".5  The display shows the list of all registered products once again. The chosen product has been ticked. 6  Repeat items 3-6 to edit additional products if required. When the products to be edited have been ticked, the list must be saved.  Press   "Edit". 7   Press     to highlight "Save list".Press   "Enter" to confirm your choice.8  The display shows that the list has been saved.  Note: The individual products can be identified by highlighting "Identify products". Highlight "Undo list" to undo your choice.   When items 1-8 have been executed and the list with products has been saved, the inter-face/repeater unit is ready for use. The interface/repeater unit is activated by pressing   "Back" for more than 3 seconds or by waiting 2 minutes. After this the display shows that the interface/repeater unit is active.
28   VELUX ENGLISH VELUX   29ENGLISH Enter Back ChangeReceiveMenuLocate YesNo  Security key   Each product has a security key ensuring that external control devices cannot communicate with your system. A common security key is created automatically during the registration process ensuring that all products in the system share the same security key.  The example shows how to change the security key in interface/repeater unit A and in the products registered in interface/repeater unit A (step 1). If you have remote con-trols or additional inter-faces/repeaters, the new security key must also be transferred to these (step 2).   The example in step 2 shows how to transfer the security key to a VELUX remote control.  Step 1: Interface/repeater unit A1   Press     to highlight "Security key".Press   "Enter" to confirm your choice.2  Press     to highlight "Change".Press   "Enter" to confirm your choice.The display now indicates that the security key has been changed.3  The display asks whether the security key of other pro-ducts is to be changed. Press   "No" to finish if this is the only interface/re-peater unit. Press   "Yes" if there are other products. Execute step 2 for these.  Step 2: Remote control B (and other products)4  Press   "Menu".5  Scroll through the menus:6  Press   to highlight "Receive".Press   "Enter" to confirm your choice.  The display indicates that the security key is being trans-ferred from interface/repeater unit A to remote control B.  Note: An interface/repeater unit can also receive a new security key from eg a remote control or another interfa-ce/repeater unit by highlighting "Receive" in item 2 above.  Note: For other types of activation controls, please refer to the instructions provided with the product in question to execute step 2.ABSystem settingsBAEnter Back       Register productsSelect productsSecurity keyEnter Back       ChangeReceive
30   VELUX ENGLISH VELUX   31ENGLISH  Step 2: Remote control B2  Insert the three batteries supplied (type AA, 1.5 volt) into the remote control as shown.3  Choose language:  Press   to highlight your language.Press   "Enter" to confirm your choice.4  Press   "Register" to start registration.5 Registration is running. This can take up to two minutes.   6  The display shows "Completed" when all products have been registered.  Note: For other types of activation controls, please refer to the instructions provided with the product in question to execute step 2.System settings  Copy system  If the products have been registered directly in the interface/repeater unit as shown on page 23, they can be copied to other interface/repeater unit or remote controls.   The copying takes place in 2 steps.   Step 2 must be completed within two minutes after implementing step 1, so please read steps 1-2 before proceeding.  The example shows how to copy the registered products from the interface/repeater unit to a VELUX remote control not yet in operation. Step 1: Interface/repeater unit A1   Menu item   is highlighted.  Press     to highlight "Copy system".Press   "Enter" to confirm your choice.ABB  Enter Back       Select productsSecurity key Copy system  EnterDansk EnglishFrançais DeutschRegister Info
32   VELUX ENGLISH VELUX   33ENGLISHCC  Signal mode The entries can be used in two ways:  Control of the functions   /   through signals on their respective entries.  Control of the functions   /   through signals on one and the same entry. Use of more than one entry  The functions  /   are controlled by their respective entries. OPEN/UP/ON is controlled by connecting C and  .  CLOSE/DOWN/OFF is controlled by connecting C and  .  STOP is controlled by connecting C with both   and  .1   Press     to highlight "Separate signals".Press   "Enter" to confirm your choice.2  The display shows that the signal mode has been saved.  Note: This mode can also be used when you want to use one of the functions   /   only, eg a rain sensor that only closes the skylight.System settings Use of one entry  The functions   /   / STOP are controlled by one and the same entry. Each time the entry is activated, the function will change.  For instance, ordinary electric light in buildings is contro-lled from a wall switch that turns the light both on and o. By choosing "Toggle signal", the interface/repeater unit is set to change between   -> STOP ->  -> STOP ->   -> STOP ->   etc each time the entry is activated.    -> STOP ->  -> STOP ->   -> STOP ->   etc is contro-lled by connecting C and   :1   Press     to highlight "Toggle signal".Press   "Enter" to confirm your choice.2  The display shows that the signal mode has been saved.  Note: The products will travel in the reverse direction to the latest activation no matter the control device. The products will always travel to maximum top or bottom position.BackBackEnter Back       Separate signalsToggle signalEnter Back       Separate signalsToggle signalEnter Back       Security keyCopy system Signal mode
34   VELUX ENGLISH VELUX   35ENGLISH MenuLocate Enter Back Register productCopy systemSecurity keyCongure   Function as repeater unitBack  Repeater unit  The repeater function extends the operation range of remote controls in the system by transmitting received RF commands. When used as a repeater, the interface/repeater unit should therefore be placed approximately halfway between the remote controls and the products to be operated.   The repeater function must be registered in remote controls as if it were a product in the same way as other products, see section Register products.    Steps 1 and 2 must be completed within ten minutes, so please read items 1-7 before proceeding.  The example shows how to activate the repeater function in the interface/repeater unit and register the function in a VELUX remote control.  Step 1:1   Press     to highlight "Repeater".Press   "Enter" to confirm your choice.2  The display shows that the repeater function has been activated.  Press   "Continue" to open for registration.3  The display shows that the repeater function is ready to be registered in the remote control.  Note: Up to three interfaces/repeater units in a system can be set to repeater function.   The operation range of remote controls cannot be extended further in the same direction by placing more repeaters after each other as commands can only be sent via one repeater. Step 2:4 Press   "Menu".5  Scroll through the menus: Press   "Enter" to confirm your choice.6  Registration is running. This can take up to two minutes.7   The display shows that the repeater function has been registered. The repeater function is only displayed in the remote control during the registration process. When registration has been completed, the function is "invisible" to the user.  Repeat step 1 and step 2 for all remote controls for which the operation range is to be extended.  Note: For other types of activation controls, please refer to the instructions provided with the product in question to execute step 2.BackContinueEnter Back     InterfaceRepeaterReset system
36   VELUX ENGLISH VELUX   37ENGLISHThe products can be combined with most intelligent building installations (IBI). The IBI system must include an output module with one or more pro-grammable outputs. When the outputs have been connected to the entries in the interface/repeater unit, the relevant products can be controlled via the interface/repeater unit. With two outputs, it is possible to control both of the functions    and   in an product or a group of products.You can control up to 200 products or groups of products individually. Howe-ver, individual control of a product or a product group requires one interface/repeater unit per product or product group. If eg a group of skylights facing south and another group of skylights facing north are to be con-trolled individually by thermostats, the two groups must have an interface/repeater unit each. Intelligent building installations

Navigation menu