6018 POCSAG CCD-2
2-line Multi-lingual Display Pager
User Manual
Version 0.0
(ENGINEERING DEPARTMENT)
Document No.: C 3G 6018 UM 9N M 0000 002 0
Name
Prepared by:
Approved by
Signature
Date
Uncontrolled (
Controlled (
Copy No.:
Document History
Date
Author
Version
Nov 22, 99
Bili Cheung
0.0
Description of Changes
Original release.
Table of Contents
1. OVERVIEW OF 6018
2. ICONS
2.1.1
2.1.2
2.1.3
2.1.4
Status Icons
Memory Bank Icons
Function Icons
Operation Icons
3. OPERATIONS
3.1
To Power On the Pager
3.2
To Power Off the Pager
3.3
Accessing Memory Banks
10
3.4
Receiving and Reading Messages
10
3.5
Individual Message Removal
11
3.6
Removing All Messages
11
3.7
Message Protection
11
3.8
Copying Message to Personal Memory Bank
12
3.9
Personal Message Alarm Setup
12
3.10
News Message Alarm Setup
13
3.11
Real Time Clock Setup
13
3.12
Alert Mode Selection
14
3.13
Appointment Alarm Setup
14
3.14
Melody Selection
15
3.15
Unread Message Alarm Adjustment
16
3.16
Font Size Changing
16
3.17
Password Setup
16
3.18
Alert Duration Adjustment
18
3.19
Auto Timer Setup
18
3.20
Silent Timer Setup
19
3.21
Message Display Duration Adjustment
19
3.22
Low Battery Alert
20
3.23
Illumination
20
DATE OF ISSUE: 4-Jan-00
Page 6 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
1. Overview of 6018
The dimensions of 6018 numeric pager are 73.5mm(L) x 50mm(W) x 18.5mm(D). Its two
dimensional drawing is shown below.
69.7mm
43.0mm
Right key
Confirm key
Left key
Function key
CIRKISYS ELECTRONICS LTD.
DATE OF ISSUE: 4-Jan-00
Page 7 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
2. Icons
2.1.1 Status Icons
The pager is outside the service area
Audio alarm mode
Vibrating alert mode
Silent mode
Auto on/off timer is being set
The silent reception function is set but inactivated
The silent reception function is set and activated
The first alarm clock is set
The second alarm clock is set
Both the first and the second alarm clocks are set
The message is protected
A password is set
Full battery indication
Half battery indication
Low battery indication
Unread message indicator, the number indicates the total
number of unread messages
Unread news indicator
2.1.2 Memory Bank Icons
User memory bank
Personal memory bank
News memory bank
CIRKISYS ELECTRONICS LTD.
DATE OF ISSUE: 4-Jan-00
Page 8 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
2.1.3 Function Icons
Making copy of user/group message to personal memory
bank
Message protection
Turning off the pager
Date and time setting
Alert mode selection
Music selection for audio alert
Appointment alarm setting
Auto on/off timer setting
Silent reception timer setting
Unread message alarm interval setting
Alert duration setting
Message display duration setting
Password setup
Deleting individual message from the current memory bank
Deleting all messages from the current memory bank
Personal message alarm setting
News message receiving alarm setting
Changing the message display font size
2.1.4 Operation Icons
Next page/screen
Exit from a current screen
CIRKISYS ELECTRONICS LTD.
DATE OF ISSUE: 4-Jan-00
Page 9 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
3. Operations
3.1 To Power On the Pager
•
Press and hold the Confirm key for 3 seconds.
•
Either an audio beeping tone or pager vibration will be generated as the power on
signal.
•
Stop the power on signal by pressing any key, the pager will then display the
status screen.
•
The pager will then enter the standby mode for power saving with the LCD turned
off.
•
The status screen can be displayed again by pressing any key.
3.2 To Power Off the Pager
•
Press the Function key to evoke the second function menu from the status screen.
•
Press either one of the arrow keys to select the ‘
•
Hold the Confirm key for 3 seconds to turn off the pager.
CIRKISYS ELECTRONICS LTD.
’ icon.
DATE OF ISSUE: 4-Jan-00
Page 10 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
3.3 Accessing Memory Banks
•
Press the Function key to evoke the first function menu from the status screen.
•
Press an arrow key to select the ‘
the user memory bank.
•
Press an arrow key to select the ‘ ’ icon and press the confirm key to access the
personal memory bank.
•
Press an arrow key to select the ‘
the news memory bank.
’ icon and press the confirm key to access
’ icon and press the confirm key to access
3.4 Receiving and Reading Messages
•
The pager will generate an audio alert, a vibration alert or remain silent when
receiving a call.
•
The following screen will be displayed simultaneously.
•
Press any key to stop the alert.
•
Press the Confirm key read the latest message.
•
The pager will notify the user the number of unread messages by displaying the
‘ ’ icon.
•
Fast message scrolling can be invoked by continuously pressing the Confirm key
(all unread messages will be displayed first).
•
The following prompt message will be displayed if there is no message.
CIRKISYS ELECTRONICS LTD.
DATE OF ISSUE: 4-Jan-00
Page 11 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
3.5 Individual Message Removal
•
Recall the message to be deleted.
•
Press the Function key to evoke the user memory bank menu.
•
Press an arrow key to select the ‘
•
Press the Confirm key to delete the message.
’ icon.
3.6 Removing All Messages
•
Press the Function key to evoke the user memory bank menu.
•
Press an arrow key to select the ‘
•
Press Confirm key to delete all the messages.
•
Protected messages will not be deleted.
’ icon.
3.7 Message Protection
•
Up to 10 messages can be protected.
•
Recall a message in the user memory bank and press the Function key to evoke
the user memory bank menu.
•
Press an arrow key to select the ‘
•
Press the Confirm key to lock the message.
•
A ‘ ’ icon would be display at the top right corner of the message screen.
•
A prompt message will be displayed if there are already 10 messages protected in
the memory.
’ icon.
CIRKISYS ELECTRONICS LTD.
DATE OF ISSUE: 4-Jan-00
Page 12 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
3.8 Copying Message to Personal Memory Bank
•
Recall a message in the user memory bank.
•
Press the Function key to evoke the user memory bank menu.
•
Press an arrow key to select the ‘
•
Press the Confirm key to copy the message to the personal memory bank.
•
A message will be prompted to the user if the personal memory is full.
•
The pager will display a screen for personal alarm setting after the message has
been copied. Follow the steps outlined in Section Personal Message Alarm Setup
to set the personal alarm, or press the Confirm key to abort.
’ icon.
3.9 Personal Message Alarm Setup
•
User can set a personal alarm to every message in the personal memory bank.
•
Select a message in the personal memory bank first.
•
Press the Function key to evoke the personal memory bank menu.
•
Press an arrow key to select the ‘
•
Press the Confirm key to enter the alarm setup screen.
•
Press an arrow key to toggle between ‘ ’ to proceed further or ‘ ’ to abort the
function.
•
Press an arrow key to locate the date and time fields.
•
Press the Confirm key to adjust the digits.
’ icon.
CIRKISYS ELECTRONICS LTD.
DATE OF ISSUE: 4-Jan-00
Page 13 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
•
3.10
A bell icon ‘ ’ will be displayed in every message screen if the alarm is set, the
crossed-bell icon ‘ ’ will be displayed if the alarm has been activated.
News Message Alarm Setup
•
User can also set a news message alarm to every mailbox in the news memory
bank.
•
After entering the news memory bank, press the Function key to evoke the news
memory bank menu.
•
Press an arrow key to select the ‘
•
Press the Confirm key to set the alarm.
•
A bell icon ‘
3.11
’ icon.
’ will then be displayed in every message screen.
Real Time Clock Setup
•
Press the Function key to evoke the first function menu from the status screen.
•
Press an arrow key to select the ‘ ’ icon.
•
Press the Confirm key to enter the real time clock setup screen.
•
Press an arrow key to locate a digit as well as the time display mode for
adjustment.
CIRKISYS ELECTRONICS LTD.
DATE OF ISSUE: 4-Jan-00
Page 14 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
•
Press the Function key to adjust the time first and to toggle among the options of
time display format.
•
Repeat the steps for date adjustment.
•
Press the Confirm key to confirm the setting and return to the status screen.
3.12
Alert Mode Selection
•
Press an arrow key to select the ‘
•
Press the Confirm key to enter the alert mode setting screen.
•
The current alert mode will be displayed in the alert mode setting screen.
•
Press an arrow key to select an alert mode among the options - ‘SILENT’,
‘VIBRATE’, ‘AUDIO’, ‘VIB-AUD’, and ‘EXIT’ (return to the status screen
without updating the setting).
•
Press the Confirm key to confirm the setting and return to the status screen.
3.13
’ icon in the first function menu.
Appointment Alarm Setup
•
User can set two appointment alarms as personal reminders in the pager.
•
Press the Function key to evoke the second function menu from the status screen.
•
Press an arrow key to select the ‘
•
Press the Confirm key to enter the appointment alarm setup screen.
’ icon.
CIRKISYS ELECTRONICS LTD.
DATE OF ISSUE: 4-Jan-00
Page 15 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
•
Press an arrow key to locate the alarm number and press the Function key to
select an alarm.
•
Repeat the steps to select an alarm mode among the options of one-off ‘
‘ ’ and disable ‘ ’.
•
If either the one-off mode or the daily mode is selected, the alarm time will be
prompted to user for alarm time setting.
•
Press an arrow key to locate the time digits.
•
Press the Function key to adjust the time.
•
Press the Confirm key to confirm the setting and return to the status screen.
•
If only one alarm is set, either the ‘ ’ or ‘ ’ icon will be displayed in the status
screen. If both alarms are set, then the ‘ ’ icon will be displayed.
3.14
’, daily
Melody Selection
•
Press an arrow key to select the ‘ ’ icon in the second function menu.
•
Press the Confirm key to enter the melody selection screen.
•
The current melody will be displayed in the melody selection screen.
•
Press an arrow key to select a call type among the options ‘A’, ‘B’, ‘C’ and ‘D’
first.
•
Press the Confirm key to confirm call type selection.
•
Press an arrow key to select a melody among the standard tone and 15 melodies.
•
Press the Confirm key to confirm the setting and return to the status screen.
CIRKISYS ELECTRONICS LTD.
DATE OF ISSUE: 4-Jan-00
Page 16 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
3.15
Unread Message Alarm Adjustment
•
Press an arrow key to select the ‘
•
Press the Confirm key to enter the unread message alarm adjustment screen.
•
The current unread message alarm setting is displayed in the adjustment screen.
•
Press an arrow key to toggle between ‘2m’ (2 minutes) and ‘--’ (disable the
function).
•
Press the Confirm key to confirm the setting and return to the status screen.
3.16
’ icon in the second function menu.
Font Size Changing
•
This function is not available for pager displaying Chinese or Thai.
•
Press an arrow key to select the ‘ ’ icon in the second function menu.
•
Press the Confirm key to toggle between large and small fonts for message
viewing.
3.17
Password Setup
•
User can set up a password for the personal memory bank for security purpose.
•
This function cannot be executed if battery power is depleted.
•
Press the Function key to evoke the third function menu from the status screen.
•
Press an arrow key to select the ‘
•
Press the Confirm key to enter the first password setup screen.
’ icon.
CIRKISYS ELECTRONICS LTD.
DATE OF ISSUE: 4-Jan-00
Page 17 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
•
User has to enter the previously set password before proceeding further (enter
‘0000’ if the pager is used for the first time).
•
Press an arrow key to locate a field.
•
Press the Function key to toggle the digits for password entry.
•
An icon will be displayed to notify the user for password re-entry if a wrong
password is entered.
•
Press an arrow key to locate a field.
•
Press the Function key to toggle the digits for password entry.
•
After the correct password has been entered, press the Confirm key to enter the
second password setup screen.
•
Again press an arrow key to locate a field and press the Function key to toggle
the digits to change the password.
•
After the password has been changed, user can move to the password
activation/deactivation field.
•
Press the Function key to select a tick ‘
cross ‘ ’to deactivate the password.
•
Press the Confirm key to confirm the setting and return to the status screen.
’ to activate the password or select a
CIRKISYS ELECTRONICS LTD.
DATE OF ISSUE: 4-Jan-00
Page 18 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
3.18
Alert Duration Adjustment
•
User can adjust the duration for both standard beeping alert and vibrating alert.
•
Press an arrow key to select the ‘
•
Press the Confirm key to enter the alert duration adjustment screen.
•
Press an arrow key to toggle among the options of ‘2s’ (2 seconds), ‘4s’, ‘6s’
and ‘8s’.
•
Press the Confirm key to confirm the setting and return to the status screen.
3.19
’ icon in the third function menu.
Auto Timer Setup
•
Press an arrow key to select the ‘ ’ icon in the third function menu.
•
Press the Confirm key to enter the first auto timer setup screen if no auto timer has
been set previously.
•
Press the Function key to enable the auto timer first, the second auto timer setup
screen will be displayed.
•
Press an arrow key to locate the digits.
•
Press the Function key to adjust the time period.
•
Press the Confirm key ( ) to confirm the setting and return to the status screen.
•
A ‘ ’ icon will be displayed in the status screen to notify the user.
CIRKISYS ELECTRONICS LTD.
DATE OF ISSUE: 4-Jan-00
Page 19 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
3.20
Silent Timer Setup
•
Press an arrow key to select the ‘
•
Press the Confirm key to enter the silent timer setup screen.
•
Press the Function key to enable the silent timer first, the second silent timer setup
screen will be displayed.
•
Press an arrow key to locate the digits.
•
Press the Function key to adjust the time period.
•
Press the Confirm key ( ) to confirm the setting and return to the status screen.
•
The ‘ ’ icon will be displayed if the silent timer has been set but not yet activated,
whereas the ‘ ’ icon will be displayed if the silent timer has been activated.
3.21
’ icon in the third function menu.
Message Display Duration Adjustment
•
Press an arrow key to select the ‘
•
Press the Confirm key to enter the message display duration adjustment screen.
•
Press an arrow key to toggle among the options of ‘8s’ (8 seconds), ‘12s’, ‘30s’
and ‘60s’.
•
Press the Confirm key to confirm the setting and return to the status screen.
’ icon in the third function menu.
CIRKISYS ELECTRONICS LTD.
DATE OF ISSUE: 4-Jan-00
Page 20 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
3.22
Low Battery Alert
•
An hourly low voltage alert will be generated when the battery voltage drops
below a certain level.
•
The ‘ ’ icon will also be displayed.
•
Stop the alert by pressing any key.
•
Power off the pager and replace the battery.
3.23
Illumination
•
Press the Function key for 2 seconds to activate the back-lighting during message
reading or from the status screen.
CIRKISYS ELECTRONICS LTD.
DATE OF ISSUE: 4-Jan-00
Page 21 of 21
DOC. NO.: C 3G 6018 UM 9N M 0000 002 0
VERSION 0.0
6018 POCSAG CCD-2 2-line Multi-lingual Display Pager User
Manual
Warning: Changes or modifications to this unit not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does not cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is
needed.
•
Consult the dealer or an experienced radio/TV technician for help.
This device compiles with Part 15 of the FCC Rules. Operation is subject to the following two
conditions. (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
CIRKISYS ELECTRONICS LTD.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 21
Creator                         : Microsoft Word
Create Date                     : 2000:01:04 12:17:17
Title                           : manual
Author                          : etltmp1
Producer                        : Acrobat PDFWriter 4.0 for Windows
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OBM6018-930

Navigation menu