Venture Global MA3000 Multi-Alert Receiver User Manual MANUAL

Venture Global Limited Multi-Alert Receiver MANUAL

User Manual

USER MANUALMulti-Alert SystemWithDual Alarm ClockMA-3000Ck
Parts and FunctionSettingBatt . LowIcon Pate(replaceable)LED DispalySpeakerAlarm IndicatorAC powerindicatorCoverOnOff3S15SOnOffOnOffOnOff Auto ManuAL1 Timer Vi bAL2 Lig ht Dim merToneVolumeMode/Setting ButtonConfirm ButtonDown BottonUp BottonBeep Sound ToneFunction On/Off SwitchVolume ControlFlasherExt. Trigg er   Alar mOut    5V OutVib Out  12VDC InDimm erCale ndarSnoo ze/St opDC 12V InVibration OutAlarm Audio OutExternal Trigger InUSB Charger (out)CalendarSnooze/StopDimmer12V Out &NC/No Relay OutBatteryCoverNO NC +12V-SETCalendar (Set Cal)    Press Mode    button once, The display show Set Cal.      Press confirm    button  to set calendar year. Press Up    / Down    button adjust the year, the year "up to 2099     Press  confirm      button  to  set  calendar  month.  Press  Up      /  Down      button  adjust  the  month.  Press confirm        button to set calendar date.     Press confirm    button to finishing and exit the calendar setting.SETClock (Set Ck)The time display will blinking when install batteries and connect to ac power. Please adjust the clock to keep the time is correct.    Press Mode    button twice, The display show Set Ck.      Press confirm    button  to set time format 12 /24 hour. Press Up    / Down    button select the 12 or 24 hour format.      Press  confirm      button  jump  to  set  minute.  Press  Up      /  Down      button  adjust  the  minute.  Press confirm    button to set hour.  Press Up/ Down button adjust the Hour.    Press confirm    button to finishing and exit the time setting mode.       *** Each time you press the confirm button, the time second will reset to zero.  (The clock will run from                     zero second after you set the clock.)  SETAlarm Time (Set A1 or A2)          Press Mode    button three or four time, The display show Set A1 or A2.      Press confirm    button to set alarm minute. Press Up    / Down    button to adjust the alarm minute.    Press confirm    button to set alarm hour.  Press Up    / Down    button to adjust the alarm hour.    Press confirm    button to set alarm melody. Press Up    / Down    button to select  the alarm melody.    Press  confirm     button to set  vibration  on  or off. Press Up    to  turn  on the vibrator. Press  down     to turn off vibrator.    Press  confirm    button to set 12V output on or off. Press Up    to turn on the 12V output. Press down   to turn off vibrator the 12V output.    Press confirm    button to set relay output on or off. Press Up    to turn on the relay output. Press down    to turn off vibrator the relay output.    Press confirm    button to finishing and exit the time setting mode.Please do not forget turn the alarm switch inside the front cover.Matching (Pair)    Press Mode    button five time, The display show Pair    Press  confirm      button  to  entering  to  pair  mode.  the display show Zone: -1 or Zone:1            Zone  1  =  Zone  1  is  empty;  Zone:  1  =  Zone  1  is  already paired with  the sensor, and  if it  continues, the  new sensor will replace the old one.    Press up    or down    button to select the zone you want to pair.    Trigger the transmitter/sensor you want to pair. The display will show linked when the pair is success. then the receiver show the sensor name, Press confirm    button to confirm or  press  up      /down      button  to  select  an  other  sensor name.If  it  do  not  show  “linked”  information,    it  show  other  zone number when trigger the sensor.  This sensor is already paired in other zone. Please ensures the sound volume is not  on the min position before setting.SENSOR NAME Defult Option OptionDoor Bell Bell D. Bell KnockDoor/window Sensor Window Door InvadeMailbox Sensor Mail M. Box LetterFall sensor Fall Al Pad HelpFlood detector Flood Empty FullToilet pull sensor Toilet Help SlipMagnet sensor Magnet Steal LostEntry mat Mat Escape EnterPIR/Driveway sensor PIR Road InvadeSound sensor Baby Cry SoundTelephone ring transmitter Phone Ring CallGarage door Garage Open G.DoorGas  detector Gas Danger AlarmT3 Smoke Danger FireT4 CO Danger FirePowerBattery LowThe receiver powered by a 12V 1.2A  AC/DC adaptor and backup by 3 pieces  ‘C’ size batteries. Install the backup batteries avoid  lost  alert information when ac power fail. The AC power indicator will lit when the ac power is good.Ext. Trigg er   Alar mOut    5V O utVib Out  12VDC InDimm erCale nda rSnoo ze/ Sto p12V/1.2A.  Receiver unit:When the backup batteries are low voltage, the low battery information “BattLo” will show on the display for 1 second every 15 seconds. Replace the batteries as soon as possible.Sensor unitWhen the battery of the sensor/Bell pusher is low voltage. It will send a battery low information with the trigger signal to the receiver. The receiver will blink the zone icon to indicate this sensor battery is low voltage. Replace the battery as soon as possible.**  The display time will blink, when the AC power and the backup batteries are lost before.  Press the reset button to stop blinking.  (The clock will run with the  internal CR2032 battery. Power loss will not affect clock accuracy) **  If ac power is fail, the USB charger, Vibration pad, and 12V output will not work. The connect is Inside the battery cover    Then display will show the melody   . Press confirm      button to confirm the default melody or press up     / down     button to select an other melody. (each type of sensor have a default melody)       The melody number from 00 to 32, The #32 is a beep tone , you can adjust the tone lever to change the pitch of the sound.        ***  Select  ‘None’ to mute this sensorSENSOR NAMEDefult Sound# SENSOR NAMEDefult Sound# SENSOR NAMEDefult Sound# SENSOR NAMEDefult Sound#Door Bell 1 Flood detector 14 PIR/Driveway sensor 13 Gas  detector 10Door/window Sensor 28 Toilet pull sensor 27 Sound sensor 31 T3 13Mailbox Sensor 12 Magnet sensor 17 Phone Ring  19 T4 13Fall sensor 29 Entry mat 15 Garage door 6Open the battery coverto install the batteries.Connect the power adaptor1 2RECEIVER
OnOff3S15SOnOffOnOffOnOffAutoManuAL1 Timer VibAL2 Light DimmerToneVolumeShow CalendarPress the calendar button once, the display will show the calendar for 10  seconds.DimmerPress the dimmer button to select the brightness of the display Alarm 1 On/Off (clock alarm 1)Slide the AL1 switch to on or off position. When Alarm 1 is on the alarm1 indicator will light upAlarm 2 On/Off (clock alarm 2)Slide the AL2 switch to on or off position. When Alarm 2 is on the alarm2 indicator will light up.TimerSlide the timer switch to select the duration of the relay output and 12V output .Light On/OffSlide the master light  switch to on or off flasher light.Vibrator On/OffSlide the Vib  master switch to turn on or off  vibrator. This is a master switch.Dimmer ModeAuto: The LED display dims automatically in the dark .Manual: Adjust the LED display brightness by pressing the dimmer button.Tone AdjustSlide the tone lever to adjust the tone of the beep sound alert (Sound number 32).Volume ControlSlide the volume to adjust master sound volume. Other SettingOutlet and inletDC Jack : Main power 12V 1A input.Dim merCal end arSno oze /St op    Press  confirm      button  to  set  vibration  on  or  off.  Press  Up  to  turn  on  the  vibrator.  Press  down  to  turn  off vibrator.    Press confirm    button to set 12V output on or off. Press Up to turn on the 12V output. Press down to turn off vibrator the 12V output.    Press confirm    button to set relay output on or off. Press Up to turn on the relay output. Press down to turn off vibrator the relay output.    Press confirm    button to finishing and goto next zone pairing.To remove the sensor from the  receiver memory (unpair).    Press Mode button five time, The display show Pair    Press confirm    button to entering to pair mode. the display show Zone  -1 or Zone:1    Press up or down button to select the zone you want to unpair.          Press  and  hold  the  up  and  down  buttons  for  approx.  3  seconds.    The  receiver  will  return  a  beep  tone  to confirm this zone is clear. The display will change to show 'zone - x'. ('X' is zone number, '-' is indicating this zone is empty.)   When the zone is paired with sensor the display  will show “:” between  the “zone” and zone number. eg. zone: 1.When the zone is empty, the display will show “-” between  the “zone” and zone number. eg. zone- 1.Ext. Trigger   AlarmOut    5V OutVib Out  12VDC InDimmerCalendarSnooze/Stop12V/1AExt. Trigger   AlarmOut    5V OutVib Out  12VDC InDimmerCalendarSnooze/StopExt. Trigger   AlarmOut    5V OutVib Out  12VDC InDimmerCalendarSnooze/StopExt. Trigger   AlarmOut    5V OutVib Out  12VDC InDimmerCalendarSnooze/StopAlarm System orAmplifierExt. Trigger   AlarmOut    5V OutVib Out  12VDC InDimmerCalendarSnooze/StopBluetooth receiverReplace the icon plateAfter  pairing  the  sensor/bell  pusher,  do  not  forget  change  the  sensor  indication  icon  come  withe  the  sensor.  Please keep the original icon plate for unpair the zone.Vib Out: Vibrator connect to this outlet. It provide 12V                 output to drive the vibrator.5V output: This is a standard USB socket. It provide  DC5V / 1A to charge the  mobile  device.  The  charge  current  depend  on  the  max  current  of power adaptor and the mobile device .(max. output current is 1A)Alarm Out: This is a  audio signal output.  It con connect to the external amplifier or other alarm system.Ext. Trigger: This is a external trigger input. you can apply a 3-12V DC to trigger this input.Open the display lensby nails Tack out the icon plate andreplace the correct one.Press the top of the icon plate to fix it. Cover back the display lensPress the bottom of the icon plate. the top of the icon plate will go outNO NC +12V-This receive provide some output terminal for special application.Normal Open(NO) terminal:This  2 terminal  pin  is  open    circuit    normally,   It  will  close circuit  when the  receiver  be  triggered.  The  duration  is  depend  on  the  timer  switch setting.Normal Close (NC) terminal:This 2 terminal pin is close circuit normally,  It will open circuit when the receiver  be  triggered.  The  duration  is  depend  on  the  timer  switch setting.Normally  open  and  normally  closed  can  only  choose  one  connection.  (The rating do not exceed48V/500mA)12V out terminal:This  2  terminal  pin  can  provide  12v  output  to  drive  some  device  when the  receiver  be  triggered.  The  duration  is  depend  on  the  timer  switch setting. The device current do not exceed 200mA.3 4
FCC Statement:This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However,  there  is  no  guarantee  that  interference  will  not  occur  in  a  particular  installation.  If  this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: *   Reorient or relocate the receiving antenna. *   Increase the separation between the equipment and receiver. *   Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1)  This  device  may  not  cause  harmful  interference,  and  (2)  this  device  must  accept  any  interference received, including interference that may cause undesired operation. Note: Modifications to this product will void the user's authority to operate this equipment.RoHS2002/95/EC

Navigation menu