Venture Global MA3000 Multi-Alert Receiver User Manual MANUAL
Venture Global Limited Multi-Alert Receiver MANUAL
User Manual
USER MANUAL Multi-Alert System With Dual Alarm Clock MA-3000Ck RECEIVER Parts and Function Setting Dimmer Flasher Snooze/Stop Calendar Icon Pate (replaceable) Snooze/Stop Calendar Dimmer External Trigger In Alarm Indicator Batt. Low AC power indicator Alarm Audio Out Vibration Out Speaker USB Charger (out) Vib Out Battery Cover Cover Alarm Out Ext. Trigger 5V Out 12V DC In DC 12V In 12V Out & NC/No Relay Out LED Dispaly Mode/Setting Button NO NC +12V- SETAlarm Time (Set A1 or A2) Press Mode button three or four time, The display show Set A1 or A2. Press confirm button to set alarm minute. Press Up / Down button to adjust the alarm minute. Press confirm button to set alarm hour. Press Up / Down button to adjust the alarm hour. Press confirm button to set alarm melody. Press Up / Down button to select the alarm melody. Press confirm button to set vibration on or off. Press Up to turn on the vibrator. Press down to turn off vibrator. Press confirm button to set 12V output on or off. Press Up to turn on the 12V output. Press down to turn off vibrator the 12V output. Press confirm button to set relay output on or off. Press Up to turn on the relay output. Press down to turn off vibrator the relay output. Press confirm button to finishing and exit the time setting mode. Please do not forget turn the alarm switch inside the front cover. Confirm Button Down Botton Up Botton The connect is Inside the battery cover Beep Sound Tone AL1 On Off AL2 Timer Vib 3S On 15S Light Off On Auto Off Off Manu Function On/Off Switch Tone Dimmer On Please ensures the sound volume is not on the min position before setting. SETCalendar (Set Cal) Press Mode button once, The display show Set Cal. Press confirm button to set calendar year. Press Up / Down button adjust the year, the year "up to 2099 Press confirm button to set calendar month. Press Up / Down button adjust the month. Press confirm button to set calendar date. Press confirm button to finishing and exit the calendar setting. SETClock (Set Ck) The time display will blinking when install batteries and connect to ac power. Please adjust the clock to keep the time is correct. Press Mode button twice, The display show Set Ck. Press confirm button to set time format 12 /24 hour. Press Up / Down button select the 12 or 24 hour format. Press confirm button jump to set minute. Press Up / Down button adjust the minute. Press confirm button to set hour. Press Up/ Down button adjust the Hour. Press confirm button to finishing and exit the time setting mode. *** Each time you press the confirm button, the time second will reset to zero. (The clock will run from zero second after you set the clock.) Volume Volume Control Power The receiver powered by a 12V 1.2A AC/DC adaptor and backup by 3 pieces ‘C’ size batteries. Install the backup batteries avoid lost alert information when ac power fail. The AC power indicator will lit when the ac power is good. Matching (Pair) Snooze/Stop Open the battery cover to install the batteries. Calendar Dimmer 12V/ 1.2A Connect the power adaptor Vib Out Alarm Out Ext. Trigger 5V Out 12V DC In ** The display time will blink, when the AC power and the backup batteries are lost before. Press the reset button to stop blinking. (The clock will run with the internal CR2032 battery. Power loss will not affect clock accuracy) ** If ac power is fail, the USB charger, Vibration pad, and 12V output will not work. Battery Low Receiver unit: When the backup batteries are low voltage, the low battery information “BattLo” will show on the display for 1 second every 15 seconds. Replace the batteries as soon as possible. Sensor unit When the battery of the sensor/Bell pusher is low voltage. It will send a battery low information with the trigger signal to the receiver. The receiver will blink the zone icon to indicate this sensor battery is low voltage. Replace the battery as soon as possible. Press Mode button five time, The display show Pair Press confirm button to entering to pair mode. the display show Zone: -1 or Zone:1 Zone 1 = Zone 1 is empty; Zone: 1 = Zone 1 is already paired with the sensor, and if it continues, the new sensor will replace the old one. Press up or down button to select the zone you want to pair. Trigger the transmitter/sensor you want to pair. The display will show linked when the pair is success. then the receiver show the sensor name, Press confirm button to confirm or press up /down button to select an other sensor name. If it do not show “linked” information, it show other zone number when trigger the sensor. This sensor is already paired in other zone. SENSOR NAME Door Bell Door/window Sensor Mailbox Sensor Fall sensor Flood detector Toilet pull sensor Magnet sensor Entry mat PIR/Driveway sensor Sound sensor Telephone ring transmitter Garage door Gas detector T3 T4 Defult Bell Window Mail Fall Al Flood Toilet Magnet Mat PIR Baby Phone Garage Gas Smoke CO Option D. Bell Door M. Box Pad Empty Help Steal Escape Road Cry Ring Open Danger Danger Danger Option Knock Invade Letter Help Full Slip Lost Enter Invade Sound Call G.Door Alarm Fire Fire Then display will show the melody . Press confirm button to confirm the default melody or press up down button to select an other melody. (each type of sensor have a default melody) The melody number from 00 to 32, The #32 is a beep tone , you can adjust the tone lever to change the pitch of the sound. *** Select ‘None’ to mute this sensor Defult Sound# SENSOR NAME SENSOR NAME Door Bell Flood detector Door/window Sensor 28 Toilet pull sensor Mailbox Sensor 12 Magnet sensor Fall sensor 29 Entry mat Defult Sound# 14 27 17 15 Defult Sound# SENSOR NAME SENSOR NAME PIR/Driveway sensor 13 Gas detector Sound sensor 31 T3 Phone Ring 19 T4 Garage door Defult Sound# 10 13 13 Press confirm button to set vibration on or off. Press Up to turn on the vibrator. Press down to turn off vibrator. Press confirm button to set 12V output on or off. Press Up to turn on the 12V output. Press down to turn off vibrator the 12V output. Press confirm button to set relay output on or off. Press Up to turn on the relay output. Press down to turn off vibrator the relay output. Press confirm button to finishing and goto next zone pairing. Show Calendar Press the calendar button once, the display will show the calendar for 10 seconds. Dimmer Snooze/Stop Calendar Dimmer Press the dimmer button to select the brightness of the display Outlet and inlet Replace the icon plate Snooze/Stop After pairing the sensor/bell pusher, do not forget change the sensor indication icon come withe the sensor. Please keep the original icon plate for unpair the zone. DC Jack : Main power 12V 1A input. Calendar Dimmer 12V/1A Vib Out Alarm Out Ext. Trigger 5V Out 12V DC In Snooze/Stop Calendar Dimmer Vib Out Alarm Out Ext. Trigger 5V Out 12V DC In Vib Out: Vibrator connect to this outlet. It provide 12V output to drive the vibrator. Snooze/Stop Open the display lens by nails Press the bottom of the icon plate. the top of the icon plate will go out Tack out the icon plate and replace the correct one. Press the top of the icon plate to fix it. Cover back the display lens To remove the sensor from the receiver memory (unpair). Press Mode button five time, The display show Pair Press confirm button to entering to pair mode. the display show Zone -1 or Zone:1 Press up or down button to select the zone you want to unpair. Press and hold the up and down buttons for approx. 3 seconds. The receiver will return a beep tone to confirm this zone is clear. The display will change to show 'zone - x'. ('X' is zone number, '-' is indicating this zone is empty.) Calendar Dimmer 5V output: This is a standard USB socket. It provide DC5V / 1A to charge the mobile device. The charge current depend on the max current of power adaptor and the mobile device .(max. output current is 1A) Vib Out Alarm Out: This is a audio signal output. It con connect to the external amplifier or other alarm system. When the zone is paired with sensor the display will show “:” between the “zone” and zone number. eg. zone: 1. When the zone is empty, the display will show “-” between the “zone” and zone number. eg. zone- 1. Alarm Out Ext. Trigger 5V Out 12V DC In Snooze/Stop Calendar Dimmer Vib Out Alarm Out Ext. Trigger 5V Out 12V DC In Alarm System or Amplifier Snooze/Stop Calendar Dimmer Other Setting Ext. Trigger: This is a external trigger input. you can apply a 3-12V DC to trigger this input. Alarm 1 On/Off (clock alarm 1) Slide the AL1 switch to on or off position. When Alarm 1 is on the alarm1 indicator will light up Vib Out Alarm 2 On/Off (clock alarm 2) Alarm Out Ext. Trigger 5V Out 12V DC In Slide the AL2 switch to on or off position. When Alarm 2 is on the alarm2 indicator will light up. Bluetooth receiver Timer Slide the timer switch to select the duration of the relay output and 12V output . Light On/Off Slide the master light switch to on or off flasher light. Vibrator On/Off Slide the Vib master switch to turn on or off vibrator. This is a master switch. Dimmer Mode Auto: The LED display dims automatically in the dark . Manual: Adjust the LED display brightness by pressing the dimmer button. Tone Adjust AL1 Slide the tone lever to adjust the tone of the beep sound alert (Sound number 32). On Off AL2 Volume Control Slide the volume to adjust master sound volume. Timer 3S 15S Light Vib On Off Tone Dimmer On On Auto Off Off Manu This receive provide some output terminal for special application. Normal Open(NO) terminal: This 2 terminal pin is open circuit normally, It will close circuit when the receiver be triggered. The duration is depend on the timer switch setting. Normal Close (NC) terminal: This 2 terminal pin is close circuit normally, It will open circuit when the receiver be triggered. The duration is depend on the timer switch setting. Normally open and normally closed can only choose one connection. (The rating do not exceed48V/500mA) 12V out terminal: This 2 terminal pin can provide 12v output to drive some device when the receiver be triggered. The duration is depend on the timer switch setting. The device current do not exceed 200mA. Volume NO NC +12V- FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: * Reorient or relocate the receiving antenna. * Increase the separation between the equipment and receiver. * Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: Modifications to this product will void the user's authority to operate this equipment. RoHS 2002/95/EC
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Format : application/pdf Creator : wwliu Title : MANUAL.cdr Create Date : 2018:01:08 12:00:46+08:00 Creator Tool : CorelDRAW X6 Modify Date : 2018:01:08 12:02:42+08:00 Metadata Date : 2018:01:08 12:02:42+08:00 Producer : Corel PDF Engine Version 16.1.0.843 Document ID : uuid:33ddc2e5-a3a1-429f-b3ae-aeda539df238 Instance ID : uuid:7f5de5c8-0720-4910-8d7b-d97f79775946 Profile CMM Type : Linotronic Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : Hewlett-Packard Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : Hewlett-Packard Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Page Count : 4 Author : wwliuEXIF Metadata provided by EXIF.tools