INSTALLER / CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE. WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas suppler. Radiance Direct Vent/Natural Vent Gas Heater Model RDVOD: 3225 thru 3232, 3350 thru 3354, 3360 thru 3369, 3390 thru 3399 WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do • • not use any phone in your building. Immediately call your gas supplier from your neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. This appliance may be installed in an after market permanently located manufactured (mobile) home where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. Homeowner’s Installation 4188 Manual and Operating DE S I GN Radiance cover 4/01 C E RT I F I E D CE RTIFI E D INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. 20004188 1/07 Rev. 18 Radiance Direct Vent/Natural Vent Gas Heater Table Of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions Assembly Procedures Operation Maintenance Replacement Parts Optional Accessories Warranty Energuide 22 General Information ....................................................................................................3 Stove Dimensions .......................................................................................................4 Installation Requirements ...........................................................................................5 Locating the Stove ......................................................................................................5 Clearance Requirements ............................................................................................5 Parallel Installation ......................................................................................................6 Corner Installation .......................................................................................................6 Wall and Ceiling Clearances .......................................................................................6 Hearth Requirements ..................................................................................................6 Gas Specifications ......................................................................................................7 Gas Inlet and Manifold Pressures ...............................................................................7 High Elevations ...........................................................................................................7 Horizontal Termination - Direct Vent ONLY .................................................................7 Vertical Termination - Direct Vent ONLY .....................................................................8 Vent Termination Clearances ......................................................................................9 General Venting Information - Termination Location .................................................10 Termination Clearances ............................................................................................ 11 Venting Requirements - Natural Vent ONLY ............................................................. 11 Venting Requirements and Options - Direct Vent ONLY ...........................................12 Tools Required ..........................................................................................................13 Parts Bag Contents ...................................................................................................13 Unpack and Assembly Legs ......................................................................................13 Install Optional Fan ...................................................................................................14 Venting System Assembly - Direct Vent ....................................................................15 Install Vent Adapter Pipe (CFM Corporation Components) ......................................15 Install Vent Adapter Pipe (Simpson Dura-Vent Components) ...................................16 Side Wall Termination Assembly ...............................................................................16 Vent Termination Below Grade .................................................................................18 Vertical (Through the Roof) Vent Assembly ..............................................................18 Venting System Assembly - Natural Vent .................................................................19 Install the Vent Pipe ..................................................................................................20 Install Rear Bracket and Log Set ..............................................................................20 Connect Gas Supply Line .........................................................................................21 Burner Information ....................................................................................................22 Install ON/OFF Switch ..............................................................................................22 Thermostat Connection (Optional) ............................................................................22 Install the Mesh and Grille ........................................................................................22 Your First Fire ...........................................................................................................23 Pilot and Burner Information .....................................................................................23 Flame & Temperature Adjustment .............................................................................23 Flame Characteristics ...............................................................................................23 Lighting and Operating Instructions ..........................................................................24 Troubleshooting - Honeywell #8420 Gas Control System ........................................25 Instructions for RF Comfort Control Valve ................................................................26 Fuel Conversion Instructions ....................................................................................30 Annual System Inspection ........................................................................................34 Logset and Burner/Cleaning and Inspection .............................................................34 Care of Cast Iron .......................................................................................................34 Cleaning the Glass ...................................................................................................34 Glass Replacement ...................................................................................................34 Gasket Replacement ................................................................................................35 Inspect the Vent System Annually ............................................................................35 Check the Gas Flame Regularly ...............................................................................35 Wiring Diagrams .......................................................................................................36 ...................................................................................................................................37 ...................................................................................................................................40 ...................................................................................................................................43 ...................................................................................................................................44 20004188 Radiance Direct Vent /Natural Vent Gas Heater Installation & Operating Instructions The Radiance Direct Vent/Natural Vent Room Heater, Model Nos. 3350 thru 3354, 3360 thru 3369 and 3390 thru 3399, is a vented gas appliance listed to the ANSI standard Z21.88b-2002 and CSA-2.33b-2002 for Vented Room Heaters, and CSA 2.17M91, Gas-Fired Appliances For Use at High Altitudes. The installation of the Radiance Direct Vent/Natural Vent Room Heater must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1/NFPA 54 — latest edition and CSA B-149.1 Installation Code. (EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5 inches w.c. for Natural Gas and 10 inches w.c. for LP gas at maximum input.) Refer to Page 30 (RF only). This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. Installation and replacement of gas piping, gas utilization equipment or accessories, and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) installation or replacement of gas piping, or (b), the connection, installation, repair, or servicing of equipment, who is experienced in such work, familiar with all precautions required, and has complied with all the requirements of the authority having jurisdiction. The Radiance Direct Vent/Natural Vent Room Heater should be inspected before use and at least annually by a qualified service agency. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean. The Radiance Direct Vent/Natural Vent Room Heater and its individual shut-off valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The Radiance Direct Vent/Natural Vent Room Heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. An accessible tap is located above the pilot/On-Off knob for checking the inlet pressure. ‘Direct Vent’ describes a sealed combustion system in which incoming outside air for combustion and outgoing exhaust enter and exit through two separate concentric passages within the same sealed vent system. The system does not use room air to support combustion. The Direct Vent system permits the gas appliance to be vented directly to the outside atmosphere through the side of the house or vertically through the roof. Conventional venting systems (Natural Vent) take air from the room for combustion and vent the exhaust vertically through the roof to the atmosphere. This appliance is approved for bedroom installations in the U.S. and Canada. Check local codes for natural vent requirements. 20004188 This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. The Radiance Direct Vent/Natural Vent Room Heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, (latest edition), or of the current Canadian Electrical Code C22.1. Due to high temperatures this appliance should be located out of traffic and away from furniture and draperies. WARNING: This appliance is hot while in operation. Keep children, clothing, and furniture away. Contact may cause burns or ignition of combustible materials. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Clothing or other flammable materials should not be placed on or near the appliance. Any safety screen, glass or guard removed for servicing an appliance must be replaced prior to operating the appliance. The appliance area must be kept clear and free from combustible materials, gasoline, and other flammable vapors and liquids. The flow of combustion and ventilation air must not be obstructed. The installation must include adequate accessibility and clearance for servicing and proper operation. WARNING: Do not operate the Room Heater with the glass panel removed, cracked or broken. Replacement of the panel should be done by a licensed or qualified service person. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Do not burn wood, trash or any other material for which this appliance was not designed. This appliance is designed to burn either natural gas or propane only. This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. * Aftermarket: Completion of sale, nor for purpose of resale, from the manufacturer. Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6 3 Radiance Direct Vent/Natural Vent Gas Heater Radiance Direct Vent/Natural Vent Stove Dimensions See Page 6 for Flue Collar Centerline Dimensions. ����������� � � 14���" (3.7cm) 7" Outer Dia. (1.8cm) 4���" (1.2cm) 29���" (7.6cm) �������� 28" (711mm) Supply Inlet 5" (127mm) 31" (7.9cm) 9���" (241mm) 18���" (464mm) 4188 Fig. 1 Radiance dimensions. ST126 RDV40 dimensions 10/99 Attention The Radiance stove is shipped from the factory as a Direct Vent Gas Heater. This heater may be converted into a Natural Vent unit in the field. If a Natural Vent Heater is desired, the Vermont Castings Z31D00 FSDHAG Draft Hood must be directly installed to the top of the unit according to the installation instructions. The Draft Hood Adapter is available in the 7FSDHASK stove kit or as a separate item. When the Radiance stove is converted to Natural Vent, it uses 4” vent pipe. For aesthetic purposes the CFM direct vent system may be used up to the ceiling. 44 20004188 Radiance Direct Vent /Natural Vent Gas Heater Installation Requirements The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5” w.c. for Natural Gas, and 10” w.c. for Propane). In Canada, installation must be in accordance with the current CSA B-149.1 Installation Codes and/or local codes. The installation should be done by a qualified service person who is familiar with the building codes and installation techniques appropriate for your area to accomplish a safe and effective installation. Your dealer or your local gas supplier will be able to refer a qualified service person. WARNING: Due to high temperatures, the HEATER should be located out of traffic and away from furniture and draperies. The surface of the Heater Is hot when it is in use. Young children should be watched carefully when they are in the same room when the Heater is in use, and they should be taught to avoid the hot surface. Keep any objects that can burn well away from the Heater, and observe the recommended clearances that follow. Locating The Stove In choosing a location for the stove, consider: • • • • The location of outside walls; Where additional heat is needed: Where family members gather most often; The vent system requirements. NOTE: We do not recommend the use of wallpaper next to this stove. Over time, radiant heat may cause the wallpaper to shrink, or may adversely affect the binders in the wallpaper adhesive. 20004188 Direct Vent System Only A D B C E D. Cross Corner A. Flat on corner wall E. Flat on wall B. Room Divider C. Island ST207a Fig. 2 Possible stove Stardance locations. Stove locations 9/28/00Requirements djt Clearance ST207a Minimum Clearances to Combustible Materials Measure side clearances as shown in Figures 3, 4 and 5 from the outer edge of the cast iron stove top. Measure rear clearances from the outermost surface of the steel rear skirt. The Radiance heater is approved for installation into an alcove constructed of combustible materials to the dimensions and clearances shown on the next page. The same clearances apply in a standard parallel installation. WARNING: • Always maintain required clearances (air spaces) to nearby combustibles to prevent fire hazard. Do not fill air spaces with insulation. All venting components must maintain a 1” (25mm) clearance to combustible materials. Maintain a 6” (150mm) clearance when using single wall pipe. • The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. • Refer to the manufacturer’s instructions included with the venting system for complete installation procedures. 5 Radiance Direct Vent/Natural Vent Gas Heater Parallel Installation: Minimum Clearance and Flue Centerline, Direct Vent and Natural Vent Wall Centerline from Floor Direct Vent Only 42" (1070mm) Min. Alcove Width 4" (102mm) 48" (1220mm) Max. Alcove Depth ST130 A 6" (150mm) 6" (150mm) Fig. 3 Parallel installation, minimum back and side clearances, and flue centerlines. ����� ������������ Corner Installation: Minimum Clearance and ����� Flue Centerline, Direct Vent & Natural Vent ST131b A Effective Minimum Centerline 57” (1448 mm) (CFM Corporation Pipe) 55” (1399 mm) (Simpson ST131b DuraVent Pipe) Stardance 18" (457mm) Fig. 5 Minimum wall centerline. wall thimble 9/28/00 djt �� Wall and Ceiling Clearances 6" (150mm) D Direct Vent Only 18" (457mm) �� B C 6" (150mm) A ST129 Fig. 4 Corner installation, minimum corner clearances and flue centerline. ����� ������������ ����� A: Rear Wall B: Min. Clearance C: Min. Alcove Height ST101b D: Max. Alcove Depth Stardance DirectClearance Vent Sidewall 4” (102 mm) 44” (1118 mm)* 72” (1830 mm)* 48” (1220 mm) 6” (150 mm) ClrncDuraVent Minimum Vent Kit #2792 or * neededMin. for installing CFM Corporation 9/28/00Minimum djt Vent Kit #7TFSMSK. ST101b Fig. 6 Dimensions and clearances to ceiling or alcove. Hearth Requirements The Radiance Heaters must be installed on rigid flooring. When the heater is installed directly on any combustible surface other than wood flooring, a metal or wood panel extending the full width and depth of the unit must be used as the hearth. There are no other hearth requirements. 66 20004188 Radiance Direct Vent /Natural Vent Gas Heater Horizontal Termination Direct Vent ONLY Gas Specifications Model Fuel Gas Control Max. Input BTU/h RDVODRN RDVODRP RDVODRFN RDVODRFP Nat Prop Nat Prop Millivolt Millivolt Comfort Control Comfort Control 35,000 35,000 35,000 35,000 Min. Input BTU/h 25,000 27,500 25,000 27,500 Weight: Fully assembled; 350 lbs. Gas Inlet and Manifold Pressures Inlet Minimum Natural 5.5” w.c. LP (Propane) 11.0” w.c. Inlet Maximum 14.0” w.c. 14.0” w.c. Manifold Pressure 3.5” w.c. 10” w.c. The vent must rise vertically a minimum of 24” (610mm) off the top of the unit, before the first elbow. The horizontal run may extend up to 20’ (6m) and include a vertical rise of up to 40’ (12m). (Fig. 7) Horizontal termination must also meet the criteria shown in Figures 10 through 12. • Approved vent systems must terminate above and including the heavy line in Figure 7. • Two 45˚ elbows may be substituted for each single 90˚ elbow. • With a rise between 2’ - 5’, one 90˚ or two 45˚ elbows may be used. �� �� �� High Elevations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level. �� Vertical Run (in feet) The installation of your Vermont Castings stove must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, or CSA B149.1 Installation code. (EXCEPTION: Do not derate this appliance for altitude up to 4,500 feet (1,370m). Maintain the manifold pressure at 3.5” w.c. for Natural Gas and 10.0” w.c. for LP Gas. �� (Measured from the appliance flue collar to the top of the vent pipe.) Radiance Direct Vent/Natural Vent Certified to: ANSI Z21.88-2005 / CSA 2.33-2005 Vented Gas Fireplace Heaters �� �� �� �� �� �� �� �� �� May use up to three 90° Elbows �� �� �� �� �� �� �� �� �� �� �� �� For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction. �� In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m). � �� � � � � ��� ��� One 90° Elbow � WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier. 20004188 ST134a FDV28 Horizontal vent run 12/3/99 djt areas modified 1/11/00 djt �� �� Unacceptable Venting Configuration � � � � � � � � � � � �� �� �� �� �� �� �� �� �� �� �� Horizontal Run (in feet) ST134a Fig. 7 Horizontal vent termination window. 7 Radiance Direct Vent/Natural Vent Gas Heater Vertical Termination - Direct Vent ONLY Vent Termination Clearances A vertical vent system must terminate no less than 8’ (2.44m) and no more than 40’ (12m) above the appliance flue collar. A 2¹⁄₄" restrictor plate (supplied) must be used, where specified, in all vertically terminated vent systems. (Refer to Figure 8) NOTE: The restrictor plate supplied with the vertical termination should be discarded. Install restrictor plate supplied with stove directly at stove outlet. A vertically terminated vent system must also conform to the following criteria: • No more than three 90° elbows may be used. • Two 45° elbows may be substituted for one 90˚ elbow. No more than six 45° elbows may be used. • Vent must rise a minimum of 2 feet before offset is used. • Termination height must conform to roof clearance as specified in Figure 9. When planning the installation, consider the location of the vent terminal and clearances. Some of the most common clearances to keep in mind are shown in Figure 9. �� �� �� �� Vertical Run (in feet) (Measure from the appliance flue collar to the top of the vent pipe.) �� �� �� �� All Vertical Terminations in this area Require use of the 2¹⁄₄” Restrictor Plate* �� �� �� �� �� Vertical terminations must be within this area ST132a FDV28 Vertical vent run 12/3/99 djt area modified 1/11/00 djt �� �� �� �� �� Unacceptable Venting Configuration �� �� te �� �� ri st �� �� �� No r o ct a Pl Re � � � � � ��� ��� � No offset may be used within this area � � � � � � � � � � � The vent termination should be located where it cannot be damaged by such things as automobile doors, lawn mowers or snowblowers and it should be located away from areas where it could become blocked by snow, etc. Some considerations are: • Obstructions or impediments to venting. • Nearby combustible materials that could come into • �� �� �� The vent should be placed so that people cannot be burned by accidentally touching the vent surfaces when the stove is operating. • �� �� Important: All vent clearances must be maintained. Check your vent termination clearances against Figures 9 through 11. �� �� �� �� �� �� �� �� �� �� Horizontal Run (in feet) contact with combustion exhaust gases. Other nearby openings {within 12” (305 mm)} through which exhaust gas could reenter the building. All vegetation within 3’ (76 mm) that may interfere with the draft. Other factors that influence where the installation will be sited include the location of outside walls, where additional heat may be desired in the home, where the family members gather most regularly, and perhaps most importantly, the distance limitations of the venting system. IMPORTANT Direct Vent Only • The horizontal termination must not be recessed into the exterior wall or siding. • Horizontal vent runs must be level toward the vent termination. • Clearances around the vent termination must be maintained. • For installations using Simpson DuraVent pipe, parallel installations with minimum wall clearance have restricted access for connecting the Horizontal Vent Cap straps to the vent pipe. See the maker’s instructions for recommended installation procedures. �� ST132a Fig. 8 Vertical vent termination window. *The Restictor Plate is used on Direct Vent installations only. 88 20004188 Radiance Direct Vent /Natural Vent Gas Heater Vent Termination Clearances Your stove is approved to be vented either through the side wall, or vertical through the roof. • CFM Corporation does not require any opening for inspection of vent pipe. • Only CFM Corporation and Simpson DuraVent venting components specifically approved and labelled for this stove may be used. • Minimum clearances between vent pipes and combustible materials is one (1”) inch (25 mm), except where stated otherwise. • Venting terminals shall not be recessed into a wall or siding. • Horizontal venting must be installed on a level plane without an inclining or declining slope. 20004188 There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24” from the front of the termination hood. Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area. Location of Vent Termination It is imperative the vent termination be located observing the minimum clearances as shown on this page. 9 Radiance Direct Vent/Natural Vent Gas Heater General Venting Information - Termination Location INSIDE CORNER DETAIL G V H A N N D L V E C B V F B ����� ������ B V Ope Operable rable V B B B V J X X AIR SUPPLY INLET M I A CFM145a V VENT TERMINATION V Fixed Closed C = Clearance to permanently closed window D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2’ (610mm) from the center line of the terminal E = Clearance to unventilated soffit F = Clearance to outside corner G = Clearance to inside corner (see next page) H = Clearance to each inside of center line extended above meter/regulator assembly K X AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installations1 A = Clearance above grade, veranda, porch, deck, or balcony B = Clearance to window or door that may be opened V CFM145a DV Termin Location 12” (30cm) 5/01/01 Rev. 12/05/01 sta 6” (15cm) for appliances < 10,000Btuh (3kW), 12” (30cm) for appliances > 10,000 Btuh (3kW) and < 100,000 Btuh (30kW), 36” (91cm) for appliances > 100,000 Btuh (30kW) US Installations2 12” (30cm) 12” (305mm) recommended to prevent window condensation 6” (15cm) for appliances < 10,000 Btuh (3kW), 9” (23cm) for appliances > 10,000 Btuh (3kW) and < 50,000 Btuh (15kW), 12” (30cm) for appliances > 50,000 Btuh (15kW) 12” (305mm) recommended to prevent window condensation 18” (458mm) 18” (458mm) 12” (305mm) see next page see next page 3’ (91cm) within a height of 15’ (5m) above the meter/regulator assembly 12” (305mm) see next page see next page 3’ (91cm) within a height of 15’ (5m) above the meter/regulator assy 3’ (91cm) 6” (15cm) for appliances < 10,000 Btuh (3kW), 9” (23cm) for appliances > 10,000 Btuh (3kW) and < 50,000 Btuh (15kW), 12” (30cm) for appliances > 50,000 Btuh (15kW) 3’ (91cm) above if within 10’ (3m) horizontally 7’ (2.13m)† I = Clearance to service regulator vent outlet J = Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliances 3’ (91cm) 6” (15cm) for appliances < 10,000 Btuh (3kW), 12” (30cm) for appliances > 10,000 Btuh (3kW) and < 100,000 Btuh (30kW), 36” (91cm) for appliances > 100,000 Btuh (30kW) K = Clearance to a mechanical air supply inlet 6’ (1.83m) L = Clearance above paved sidewalk or paved 7’ (2.13m)† driveway located on public property M = Clearance under veranda, porch, deck or 12” (30cm)‡ 12” (30cm)‡ balcony N = Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18” (450mm). 1 In accordance with the current CSA-B149 Installation Codes 2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes † A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings ‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: NOTE: 1. Local codes or regulations may require different clearances. 2. The special venting system used on Direct Vent Stoves are certified as part of the appliance, with clearances tested and approved by the listing agency. 3. CFM Corporation assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements. Fig. 9 Vent termination clearances. 1010 20004188 Radiance Direct Vent /Natural Vent Gas Heater Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner G= Combustible 6" (152 mm) G F= Combustible 6" (152 mm) Noncombustible 2" (51 mm) V Noncombustible 2" (51 mm) V C V E O F Balcony with perpendicular side wall Balcony with no side wall D C E = Min. 6” (152 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O = 8’ (2.4 m) Min. M M V V P Combustible & Noncombustible M= Combustible & Noncombustible 12" (305 mm) M = 24" (610 mm) P = 20” (508 mm) No. of Caps 1 2 3 4 DMin. 3’ (.9 mm) 6’ (1.8 m) 9’ (2.7 m) 12’ (3.7 m) CMax. 2 x DActual 1 x DActual 2/3 x DActual 1/2 x DActual DMin. = # of Termination caps x 3 CMax. = (2 / # termination caps) x DActual 584-15 *NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap. Fig. 10 Termination clearances. Venting Requirements - Natural Vent Only Vertical Run (in feet) (Measured from top of the unit before any elbow) �� �� �� �� A Venting Runs B �� �� NOTE: When venting staight vertical, without any elbow, a minimum of 8 ft. vertical is required off the top of the stove. = Acceptable venting configuration �� = Unacceptable venting configuration �� �� A: Vertical installations up to 36 feet (12m) in height. Up to an 18 ft. horizontal vent run can be installed within the vent system using a maximum of two 90-degree elbows or four 45-degree elbows. �� �� �� �� �� � � � � ������������������������������������������������������ B: Vertical installations up to 36 feet (12m) in height. Up to a 24 ft. horizontal vent run can be installed within the vent system using a maximum of two 45-degree elbows. (Ratio = 2/3, Hor./Vert.) Horizontal Run (in feet) Fig. 11 Vent termination window - Natural Vent ONLY. 20004188 NOTE: When using the FSDHAG, the restrictor plate supplied with the stove is not used. 11 ����� ���������������������� �������� Radiance Direct Vent/Natural Vent Gas Heater Venting Requirements and Options Direct Vent ONLY Approved Vent System Components The Stardance Heater must be vented to the outdoors through an adjacent exterior wall or through the roof. The venting system must be comprised of the appropriate listed venting components specified on this page. These parts are available from DuraVent Corporation or your Vermont Castings Dealer. See Figure 4 for dimensions relevant to the standard minimum-vent kits. Simpson DuraVent Components Minimum Horizontal Vent Kit 2792 Starter Pipe Assembly (incl. inner & outer sections) 2768* 90° Elbow, Blk. 990B* 45° Elbow, Gal. 945 6” Straight, Blk. 908B* 9” Straight, Blk. 907B 911B 11” - 14⁵⁄₈” Adjustable Straight Section 12” Straight 906 24” Straight 904B* 36” Straight 903B 48” Straight 902 Horizontal Vent Cap 984* Wall Plate 940* Vinyl Siding Shield 950 Snorkel Termination - 14” 982 Snorkel Termination - 36” 981 Wall Strap 988 Cathedral Ceiling Support Box 941 Storm Collar 953 Firestop Spacer 963 Flashing 0/12 - 6/12 943 Flashing 6/12 - 12/12 943S Steel Chimney Kit A 931 Kit B 932 Kit C 933 Masonry Chimney Kit 934 Vertical Termination Cap (High Wind) 991 Vertical Termination Cap (Low Profile) 980 *Included in Minimum Horizontal Vent Kit #2792 All DuraVent Straight vent pipe sections have a net length 1¹⁄₂” (37mm) less than the nominal dimension; i.e., a 6” (152mm) Straight pipe section has an effective length of 4¹⁄₂” (115mm). CFM Vent Components The following kits are available to meet the needs of most installations. All pipe has a 7” outer diameter and includes a 4” diameter inner section. A (CG) designation indicates the part is finished in Charcoal Gray paint. Consult your dealer about other vent parts that may be appropriate to complete the installation. Min. Through the Wall Vent Kit 7TFSSK (1) 90-Degree Elbow (CG) (1) 24” Straight pipe (CG) (1) 24” - 42” Adjustable Straight Pipe (1) Side Wall Termination (1) Firestop (1) Zero-clearance sleeve (1) Hardware package (1) Finishing plate (CG) (1) Finishing collar (CG) (4) Charcoal Gray flue pipe rings Starter Kit for Below-Grade Termination 7TDVSKS (1) Snorkel Termination (7TDVSNORK) Vertical Termination Kit, 1/12-6/12 Pitch 7TDVSKVA (1) Combination Horizontal Offset / Roof Support (1) Vertical Termination (1) Storm Collar (1) 1/12-6/12 Flashing (1) Finishing Plate (CG) (1) Finishing Collar (CG) (1) Polished Brass Flue Pipe Ring (1) Hardware Package Vertical Termination Kit, 7/12-12/12 Pitch 7TDVSKVB (1) 7/12 - 12/12 Flashing and all of the other Vertical Termination parts. Vertical Termination, Flat Roof 7DVSKVF (1) Flat Flashing and all of the other Vertical Termination parts. Twist Lock 12” Straight Pipe (CG) 7TFSDVP12 (1) 12” Non-adjustable Pipe Twist Lock 12” - 18” Adjustable Pipe 7TFSDVP1218 (1) 12” - 18” Adjustable Pipe Twist Lock 24” Straight Pipe (CG) 7TFSDVP24 (1) 24” Non-adjustable Pipe Twist Lock 48” Straight Pipe (CG) 7TFSDVP48 (1) 48” Nonadjustable Pipe Twist Lock 45-Degree Elbow (CG) 7TFSDVT45 for vertical offsets (1) 45-degree Elbow Draft Hood Adapter FSDHAG NV Stove Kit 7FSSK (1) 7” Diameter Polished Brass Trim Ring (1) 48” Nonadjustable Pipe (CG) (1) 24” Nonadjustable Pipe (CG) (1) Finishing Plate (1) Finishing Collar (CG) (1) 90 Degree Elbow (CG) Stove Kit 7FSDHASK Includes all parts in the 7FSSK plus the Draft Hood Adapter FSDHAG Combination Offset/Roof Support 7DVCS Attic Insulation Shield 7DVAIS 7” Charcoal Gray Pipe Rings, (4) 7FSDRG 7” Polished Brass Pipe Rings (4) 7FSDRP Wall Thimble 942G NOTE: Direct vent pipe may be used on the Natural Vent system from the top of the draft hood adapter to the ceiling. 1212 20004188 Radiance Direct Vent /Natural Vent Gas Heater Assembly Procedures WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved for use with this heater may result in property damage or personal injury. This heater and components are heavy. Have help available for assembly. Tools Required • Phillips screwdriver (stub) • power drill • utility knife • reciprocating saw • metal drill bit: size 28 (.140”/3.5mm) Parts Bag Contents: • • • • • • • • • • • Control door handle/screw (3) Vent Screws (2) Switch bracket screws Ceramic handle w/insert lifter (handle for operable door) On-Off switch, housing, and wiring harness (3) Phillips round-head bolts, 1/4”- 20 x 1/2” (2) Bag of Lava Rocks (1) Tube of Vent Gasket Cement (1) Vent Restrictor Plate, 2¹⁄₄" inside diameter Owner Registration Card (4) CS, Hex Hd 3/8-16 x 1 Gr 2-Z (4) Washer, Fl 3/8-Z Unpack and Assemble Legs The Radiance is shipped upright. Cut the shipping straps and set stove upright. 1. Slide stove to the rear of the pallet just far enough to access rear leg holes. Make sure the stove does not tip over backwards. (Fig. 12) 2. Attach the rear legs using 3/8” hex head bolts and flat washer supplied. Tighten with a 9/16” wrench or socket. 3. Carefully tip the stove onto its rear legs. Adjust the pallet to allow access to one of the front leg holes. Be sure to leave the pallet under the stove to prevent the stove from falling fully forward. (Fig. 13) CAUTION: To prevent valve tubing from being crushed or damaged, make sure to rest valve on wooden pallet. 20004188 ST720 Fig. 12 Slide stove back just far enough to access rear leg holes. ST720 Radiance slide stove back 7/30/02 djt Washer Hex Head Bolt Fig. 13 Carefully tip stove onto back legs. Leave pallet under stove to keep stove from falling fully forward. ST721 4. Have your assistant attach one leg using the hardRadiance ware described. attach 5. Move the pallet to allow access to the other front leg hole. Attach remainingfront leg. legs 7/30/02 6. Remove pallet and allow stove todjt gently rest on all four legs. 7. Adjust leg levelers to compensate for irregularities in the hearth. NOTE: Verify the two relief doors (located on top of the firebox) are properly seated on the gasket. The doors should sit flush on the gasket, and should lift easily from the seal around the opening. 13 Radiance Direct Vent/Natural Vent Gas Heater WARNING This appliance is equipped with a three-prong (grounded) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. Install the Optional Fan If you are installing the optional convection Fan Kit #2767 (FK26), continue here. It is easiest to install fan kit before connecting gas line. If you are not installing a Fan Kit, go to Page 15, Venting System Assembly. 1. The fan kit includes a Blower Assembly and a Rheostat Assembly, connected by a cable. (Fig. 14) The Blower Assembly mounts to the bottom rear of the stove, and the Rheostat mounts to the valve coverplate. The assembly includes a ‘snapstat’ which automatically turns the fan On (or Off) above (or below) approximately 109˚. The Rheostat also provides a range of fan speed settings from Off (which overrides the snapstat function) to High. Unpack and inspect the Blower assembly. Confirm that the fan spins freely. Not Used On RF Models Not Used On Radiance ST147 Fig. 15 Remove rear shroud. ST147 RDV40 remove rear shroud 10/99 Side Shield Snapstat Snapstat Bracket Snapstat/ Extension Assembly Bolts Rheostat Assembly ST149 Fig. 16 Attach blower assembly and snapstat. • Remove retaining nut from shaft of rheostat. (if preinstalled) Not Used On RF Models Blower Assembly ST473 • Connect to PC board on RF models only Fig. 14 Fan kit components. ST473 2. Remove the rear shroud panel (Fig. 15) and fasten Fan parts the blower assembly toFK26 the firebox back with the two #2767 9/29/00 bolts provided. (Fig. 16) NOTE: Steps 3 and 4 do not apply when the RF valve is used. After attaching blower assembly to the firebox, run the spliced female leads to the front of the stove and attach to back of RF valve. (Page 30, Fig. 57) 3. Attach the snapstat assembly to the snapstat bracket with two sheet-metal screws. Attach the snapstat bracket to the side shield. (Fig. 16) 4. The rheostat control switch attaches to the left side of the valve bracket at the front of the stove. (Fig. 17) 1414 • Insert theST149 rheostat through the hole in the back • • of the leftrdvside offanthe valve bracket, aligning the attach assy 10/99 locator pin with the smaller hole in that bracket. Thread the retaining nut onto the shaft of the rheostat, tightening with a wrench. Do not overtighten. Attach the control knob to the rheostat shaft. Use the wire tie to secure the fan and rheostat wire harnesses together. Rheostat Rheostat Retaining Collar Rheostat Knob ST347a Fig. 17 Attach the fan rheostat. ST347a JUV FK28 rheostat install 9/21/00 20004188 Radiance Direct Vent /Natural Vent Gas Heater Venting System Assembly - Direct Vent General Information The Radiance is approved for installation only with the vent components listed on Page 11. Follow the vent component instructions exactly. 4. Attach the Inner Vent Assembly to the stove. • Run a bead of sealant around the bottom end of the starter pipe and attach the assembly to the stove using three 1/4-20 x 3/8” Phillips screws provided in the parts bag. (Fig. 20) For U.S. installations: The venting system must conform with local codes and/or the current National Fuel Gas Code, ANSI Z223.1/NFPA 54. First Section of Vent Pipe For Canadian installations: The venting system must conform to the current CSA B149.1 installation code. Install the Vent Adapter Pipe 1/4”-20 x 1/2” Phillips Screw (CFM Corporation Vent Components) 1. Install the Restrictor Plate. Consult Page 7, Figure 8 to determine whether the restrictor plate is needed. If so, place the restrictor plate within the inner flue collar as shown in Figure 18. ENT 4” Inner Starter Pipe CEM ST211 Fig. 19 Connect the inner starter with the next section of inner vent pipe. ST211 attach inner pipe to next section 12/4/99 djt ENT CEM ST647 Fig. 18 Install the restrictor plate only if required for the venting configuration. Refer to Page 7. 2. Attach Inner Starter Pipe, (found in with the logset), to the next section of inner pipe. plate • Run a beadST647install of sealantrestrictor about 1/2” from the upper 4/20/01 djt end of the Inner starter pipe and join the two sections together. • Drill three pilot holes into the Inner Starter and secure the assembly with three sheet metal screws. (Fig. 19) 3. Dry fit the Inner Pipe assembly to the stove for the purpose of determining the center line of the pipe on the wall. • Side Wall Terminations: Dry fit the outer elbow with the vertical outer vent and confirm the centerline alignment with the wall thimble opening. 20004188 ST648 Fig. 20 Attach inner assembly to flue collar. 5. Install the Outer Adapter Pipe. Insert the pipe over the stove flue collar, keeping the vertical seam oriented to the back of the stove. Also, be sure to align holes on the pipe with the holes on the flue collar of the firebox. Fasten the pipe to the holes in the flue collar with the #12 x 1/2” sheet metal screws ST647 provided. (Fig.attach 21) inner assy 4/20/01 djt 15 Radiance Direct Vent/Natural Vent Gas Heater ST650 Fig. 21 Fasten outer pipe with #12 x 1/2” sheet metal screw. ST651 Fig. 23 Simpson Dura-Vent - install outer adapter pipe. Side Wall Termination Assembly Install the Vent Adapter Pipe (Simpson Dura-Vent Components) 1. Install the Restrictor Plate. Consult Page 7 to determine whether the restrictor plate is needed. If so, ST650 place the restrictor the inner flue collar install plate outerwithin adpater as shown in Figure 18. 4/20/01 djt 2. Discard the inner starter pipe shipped with the logset. Using the starter pipe assembly listed on Page 12, slide the inner section out to allow access. • Run a bead of sealant around the bottom end of the starter pipe and attach the assembly to the stove using three 1/4-20 x 3/8” Phillips screws provided in the parts bag. (Fig. 22) 3. Install the Outer Adapter Pipe. Orient the vertical seam to the rear, and insert the crimped end of the outer pipe into the flue collar. Fasten with three sheet metal screws provided. (Fig. 23) 1. Locate the vent opening on the wall. Refer to Page 6, Figure 5, to determine the opening centerline. It may be necessary to first position the stove and measure to find the hole location. Depending on whetherST652 the wall is made of combustible materivent to the size shown in Figure als, cut dura the opening 24. Combustible wall openings attach outer assy must be framed as shown in Figure 24. 4/20/01 djt CFM System 9³⁄₈” (240mm) 9³⁄₈” (240mm) Combustible Wall DuraVent System 10” (254mm) Inner Adpater Pipe 1/4-20 x 3/8” Phillips Screws 10” (254mm) VO584-100 ENT 7¹⁄₂” Noncombustible Wall Fig. 24 Locate vent opening. CEM ST649 Fig. 22 Simpson DuraVent - install inner adpater pipe. 1616 Framing Detail 2. Measure the wall thickness and cut the wall sleeve sections to proper length (MAXIMUM 12”). Assemble the sleeve with the #8 sheet metal screws supplied. Attach the firestop plate to the sleeve end with the VO584-100 holes. (Fig. 25) NOTE: The wall sleeve is required Vent Opening in combustible walls only. 2/99 djt 3. Install the Wall Firestop/Sleeve assembly into the wall cutout and fasten the firestop to the wall cutout framing members. (Fig. 25) 20004188 Radiance Direct Vent /Natural Vent Gas Heater 12” (305mm) Max. Length Sleeve #8 Sheet Metal Screws Firestop ZCS103 Fig. 25 Assemble the wall sleeve and firestop. ZCS103 For DuraVent pipe only: Install vent pipe by alignZero Clearance Sleeve ing the locking system together, sliding the pipes & Firestop together and12/6/99 twisting djt clockwise. 6. Install the elbow using 3 sheet metal screws at each joint. 7. Measure, and cut if needed, the appropriate length of pipe section needed to make the connection through the wall. Include a 2” overlap; i.e. from the elbow to the outside wall face, about 2” or the distance required if installing a second 90° elbow. (Fig. 27) 8. Slip the wall plate and trim collar over the interior end of the horizontal pipe and install into the wall sleeve. Seal the joint inside the wall plate if needed to keep cold air from being drawn into the home. 9. Connect the horizontal pipe to the elbow. Fasten the wall plate to the pipe with three sheet metal screws. Slide the trim collar up against the wall plate to cover the screws. (Fig. 28) • Install 90° elbow. Twist lock as before. • Slide the wall plate over horizontal run before at- taching the horizontal run to the elbow. Fasten wall plate to wall. 4. For CFM Vent Pipe only: If necessary, measure to determine the vertical length (X) of pipe required from the adapter pipe to the wall cutout centerline, including a 2” overlap at the joint. (Fig. 26) use a hacksaw or tin snips to trim the pipe as needed. X ST215 Fig. 27 Measure the horizontal length. Trim Collar Wall Sleeve ST215 measure thru wall 12/6/99 djt X ST216 RADIANCE Wall Plate Fig. 28 Install the horizontal pipe and wall plate parts. ST652 Fig. 26 Determine the vertical pipe length. 5. Install first the inner then the outer straight pipe ST214a section(s), trimmed end down,vertical to thevent point of the elmeasure bow. Drill 3 holes through each 12/6/99 djtjoint and fasten with sheet metal screws. 20004188 10. For both CFM and DuraVent Systems: Install the vent terminal. (Fig. 29) Apply high temperature sealant one inch from the ends of the inner and outer ST216 collars. Guide the inner and outer vent termination install pipes. pipe thru wall collars into the adjacent Double check that 12/6/99 djt the vent pipes overlap the collars by 2”. Fasten the termination to the wall with the screws provided, and caulk the joint with weatherproof sealant. 17 Radiance Direct Vent/Natural Vent Gas Heater 11. For CFM only: Install Charcoal Gray Pipe Rings (#7FSDRG) or Polished Brass Pipe Rings (#7FSDRP) at pipe joints, if desired. Recessed Wall Firestop Seal Both Terminal Ends Finishing Collar Sheet Metal Screws and Bracket Wall Screws and Anchors Waterproof Seal Around Pipe 7” Pipe Wall Plate Caulk Plate Joint with Weatherproof Sealant ST217 Fig. 29 Install the vent terminal. Vent Termination Below Grade ST217 Install Snorkel Kit #7FSDVSKS when it is not possible install wall terminal to meet the required12/6/99 vent termination clearances of 12” djt (305mm) above grade level. The snorkel kit will allow installation depth of down to 7” (178mm) below grade level. The seven inches is measured from the center of the horizontal vent pipe as it penetrates the wall. If the venting system is installed below grade, a window well must be installed with adequate and proper drainage. (Fig. 31) NOTE: Be sure to maintain side wall clearances and vent run restrictions. Refer to Page 6, Figures 3, 4, 5, 6. 1. Establish the vent hole through the wall. 2. Remove soil to a depth of approximately 16” (406 mm) below the base of the snorkel. Install a window well (not supplied). Refill the hole with 12” (305mm) of coarse gravel and maintain a clearance of at least 4” (102 mm) below the snorkel. (Fig. 31) 3. Install the vent system as described on pages 15-18. 4. Be sure to make a watertight joint around the vent pipe joint at the inside and outside wall joints. 5. Apply high temperature sealant around the inner and outer snorkel collars. Join the pipes and fasten the snorkel termination to the wall with the screws provided. 6. Level the soil to maintain a 4” clearance below the snorkel. If the foundation is recessed, use extension brackets (not supplied) to fasten the lower portion of the snorkel. Fasten the brackets to the wall first, and then fasten to the snorkel with self-tapping #8 x 1/2” sheet metal screws. Extend the vent pipes out as far as the protruding wall face. (Fig. 30) 1818 ST219 Fig. 30 Use extension brackets to mount snorkel against recessed wall. Wall Screws and Anchors Snorkel Termination Cap Waterproof Seal ST219 Around Pipe snorkel detail Firestop 12/6/99 djt 4” Clearance Gravel Drain Window Well RADIANCE ST653 Fig. 31 Snorkel kit installation. ST653 Vertical (Through the Roof) install snorkel Vent 4/20/01 Assembly djt Note that all vertically terminated installations must, where specified, use the restrictor plate to comply with Vertical Termination Window (Page 7, Figure 8), included in the hardware bag. The plate must be installed within the firebox inner flue collar to insure a proper air/fuel ratio is maintained in an appliance vented through the roof. 20004188 Radiance Direct Vent /Natural Vent Gas Heater Make certain the vent system conforms to all other requirements for vertical termination as specified on Page 9. This installation will require you to first determine the roof pitch and use the appropriate vent components. Refer to Figure 9 on page 9. 1. Locate the final position of the stove, observing all clearances for both the vent and the stove. 2. Plumb to the center of the inner (4”) flue collar from the ceiling above, and mark that location. 3. Cut the opening: CFM System: 9³⁄₈” x 9³⁄₈” (240 x 240 mm) DuraVent System: 10” x 10” (254 x 254 mm) 4. Plumb any additional opening through the roof or other construction that may be needed. In all cases, the opening must provide a minimum of 1” (25 mm) clearance to the vent pipe. 5. Place the stove in its final position. 6. Install firestop(s) #7DVFS and Attic Insulation Shield #7DVAIS as needed. (Fig. 32) If there is a room above ceiling level, a firestop must be installed on both the bottom and top sides of the ceiling joists. If an attic is above ceiling level, an attic insulation shield must be installed. #7DVAIS Attic Insulation Shield Use Four 8d Nails #7DVFS Firestop in Upper Floor Use three #5 sheet metal screws at each joint Sealant Storm Collar Upper edge of flange goes under upper shingles #7DVSKV (A, B, or F) Roof Support Flashing ST221 Fig. 33 Roof support and flashing. Venting System Assembly - Natural Vent General Information ST221 from the factory as a The Radiance Heater is shipped vent roof to a Natural Direct Vent Heater. It may be thru converted 12/99 Vent heater by installing the Vermont Castings Model Z31D00 FSDHAG Draft Hood Adapter. The Radiance Heater is approved for installation as a Natural Vent unit. Vermont Castings/Majestic Direct Vent outer pipe (7FSSK) could be used directly after the Draft Hood Adapter up to the ceiling, then B-vent pipe must be used. Do not mix types of B-vent pipe; use components from one maker or the another. Follow the vent component maker’s instructions exactly. (Fig. 34) NOTE: The restrictor plate supplied with the stove is not used for Natural Vent applications. ST222 #7DVFS Firestop in Ceiling Fig. 32 Install firestops and attic insulation shield. 7. Install the appropriate roof support and flashing, making certain thatST222 the upper flange of the flashing vent thru ceiling base is below the shingles. (Fig. 33) 12/99 8. Install appropriate pipe sections until the vent run reaches above the flashing. The enlarged ends of the vent sections always face downward. 9. Install the storm collar and seal around the joints. (Fig. 33) 10. Add additional vent lengths to achieve the proper overall height. 11. Apply cement to the inner and outer termination collars and install the terminal cap. 20004188 Decorative 7” Pipe 4” B-vent Pipe Vermont Castings/ Majestic outer pipe (7FSSK) may be used after Draft Hood up to the ceiling. Draft Hood Adapter MUST Be Kept Clear ST654 Fig. 34 Decorative 7” pipe may be fitted around the B-vent pipe. 19 Radiance Direct Vent/Natural Vent Gas Heater The Radiance stove, when installed as a Natural vent heater, includes a vent safety switch. (Page 34, Figure 67) Operating the stove when it is not connected to a properly installed and maintained venting system, or tampering with or disconnecting the vent safety switch, can result in carbon monoxide (CO) poisoning and possible death. Install Log Set Before beginning log installation, remove stove front and glass frame. Refer to Figures 36 and 37. For U.S. installations: The venting system must conform with local codes and/or the current National Fuel Gas Code, ANSI Z22.1. For Canadian installations: The venting system must conform to the current CSA B149.1 installation code. Install the Vent Pipe Apply a bead of sealant around bottom end of inner starter pipe (found in bag with logset) and attach to stove. Apply a bead of sealant around top of inner starter pipe and install the Z31D00 FSDHAG Draft Hood according to Draft Hood instructions. (Fig. 35) Attach the first section of venting to the draft hood. Depending on the length of the individual venting sections and the lengths of the decorative pipe (if installed), you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones. The sections of decorative pipe should be oriented with their seams (if any) toward the wall; sections usually do not need to be fastened at each joint, other than slip sections. If the layout includes a slip section, this should be the last section of pipe visible in the room, at the ceiling. Complete the venting according to the vent maker’s instructions. * Refer to FSDHAG instructions for wiring on Page 34 NT �M��E ��� CE ST655 Fig. 35 Install draft hood adpater (FSDHAG). 2020 ST139 Fig. 36 Remove the stove front. ST139 Radiance remove front 4/20/01 djt ST141 Fig. 37 Release the latches to remvoe the glass frame. 1. Remove the logs from their packaging, and inspect each piece for damage. DO NOT INSTALL DAMST141 AGED LOGS. The rear log pull bracket glass latchis shipped packaged with the logs. 10/99 2. Install the rear left log by placing it on the sheet metal shelf at the back of the firebox. (Fig. 39) The log should touch the back wall of the firebox. Slide the log to the left until the left side lines up with the left bracket. (Fig. 39) When the log is in place the left front corner of the log should rest on the decorative grate. 3. Install the rear right log by placing it on the sheet metal shelf at the back toward the right. Make sure the right side of the log lines up with the right bracket. (Fig. 39) NOTE: When the right and left rear logs are in place, they should touch the back of the firebox and each other. 20004188 Radiance Direct Vent /Natural Vent Gas Heater Rear Log Bracket Log rests on decorative grate LG158 LG155 Fig. 40 Completed log installation. Fig. 38 Radiance firebox. LG156 Radiance logs Right Log djt Right 4/23/01 Rear Log Lava Rock Left Rear Log Left Rear Log LG155 Top View Radiance logs installed 4/24/01 djt Right Rear Log Lava rock may be placed in this area Decorative Grate LG160 Fig. 41 Lava rock placement. LG160 RNV logs Connect the Gas Supply Line Left Bracket Decorative Grate Right Bracket LG156 Fig. 39 Install the left and right rear logs and the right log. LG156 4. Install the right log by engaging Radiance logshole on the bottom with pin on the right rear log. (Fig. 40) Set the bottom 4/23/01 djt bring forward to come of the log on the bracket and in contact with decorative grate on right. 5. Loosely sprinkle the lava rocks directly on top of the burner just behind decorative grate. (Fig. 41) Use the lava rock to cover brackets on the burner. Do not place lava rocks toward back of burner. The lava rock is shipped inside the bag assembly. top view 6/4/01 djt Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Radiance may be converted from one gas to another using the appropriate Fuel Conversion Kit listed on page 30. In the U.S.; Gas connection should be made in accordance with current National Fuel Gas Code, ANSI Z223.1/NFPA 54. Since some municipalities have additional local codes, be sure to consult your local authority. In Canada; consult the local authority and CSA-B149.1 installation code. Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing. Light the pilot according to the directions on Page 24, before going to the next step. 20004188 21 Radiance Direct Vent/Natural Vent Gas Heater CAUTION This appliance should only be connected by a qualified gas technician. Test to confirm manifold pressures as specified below. The Radiance Heater and its individual shutoff valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The Radiance Heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig. Install ON/OFF Switch The switch assembly parts are found in the parts bag. 1. Attach switch assembly to left rear side of stove shroud (when facing shroud) using two screws and existing holes in shroud. (Fig. 42) 2. Run wires down back of stove, under bottom of rear shroud to valve. 3. Attach wires to valve terminals. (Fig. 43) Switch Assembly Existing Holes There must be a gas shutoff between the stove and the supply. In order to connect Natural Gas, use a fitting with 1/2” NPT on the valve side and 1/2” natural gas supply line with an input of 35,000 BTUs at a manifold pressure of 3.5” between minimum inlet supply of 5.5” w.c. and maximum of 14.0” w.c. ST315 Fig. 42 Attach switch assembly to rear shroud. PILOT ADJ TPTH In order to connect Propane, use a fitting with 1/2” NPT on the valve side and 1/2” propane gas supply line with an input of 35,000 BTUs at a manifold pressure of 10.0” between a minimum inlet supply of 11.0” w.c. and maximum of 14.0” w.c. Screws TP Burner Information Conversion instructions are provided with each kit and beginning on Page 29 in this manual. THIS APPLIANCE SHOULD BE CONNECTED TO THE GAS SUPPLY ONLY BY A QUALIFIED GAS SERVICE TECHNICIAN. FOLLOW ALL LOCAL CODES. THERE MUST BE A GAS SHUT-OFF BETWEEN THE STOVE AND THE SUPPLY. In order to connect Natural Gas, use a fitting with 1/2” NPT on the valve side and 1/2” natural gas supply line with an input of 35,000 BTUs at a manifold pressure of 3.5” between minimum inlet supply of 5.5” w.c. and maximum of 14.0” w.c. In order to connect Propane, use a fitting with 1/2” NPT on the valve side and 1/2” propane gas supply line with an input of 35,000 BTUs at a manifold pressure of 10.0” between a minimum inlet supply of 11.0” w.c. and maximum of 14.0” w.c. 2222 TH The appliance must only use the gas specified on the rating plate, unless converted using a Vermont Castings Fuel Conversion Kit. To convert from LP to Natural Gas use Kit #000-5009. To convert from Natural Gas to LP use Kit #000-5010. ST315 Fig. 43 Attach switch wires to valve. attach switch assy Thermostat Connection (optional) 1/31/00 djt ST228 ST228 Use only a thermostat rated for 500 - 750 millivolts. attach switch Check the table below for the appropriate gauge therwires to valve mostat wire to use for the length of lead required in your 12/99 installation. Thermostat Wire / Gauge Maximum Run 18 20 feet 16 20 - 40 feet 14 up to 60 feet 1. Install the wall thermostat in the desired location and run the wires to the stove location. Terminate these leads with 1/4” female connectors. 2. Connect the thermostat wires to the valve. (Fig. 43) Install the Mesh and Grille Place the mesh and grille on the top of the Radiance stove to complete assembly. 20004188 Radiance Direct Vent /Natural Vent Gas Heater Operation The Radiance is shipped with the operable door front plate. The stove may be operated with the doors either open or closed. To open the front doors, insert the handle into the door latch stub and turn it to the right and up. (Fig. 44) When not in use, the handle may be stored in the handle holder on the right side of the rear shroud. (Fig. 45) Pilot Assembly Counterclockwise to Open ST476 Fig. 46 Pilot Assembly location. ST477 Adjustment Flame & Temperature Stardance Clockwise to Close ST621 Fig. 44 To open the front doors, turn handle counterclockwise. Handle Holder Turn counterclockwise to decrease flame height �� For stoves equipped withpilot HI/LO valves, flame adjustlocation ment is accomplished by10/4/00 rotating the HI/LO adjustment knob located near the center of the gas control valve. (Fig. 47) �� Turn clockwise to increase flame height Fig. 47 Flame adjustment knob for Honeywell valve. RADIANCE Flame Characteristics ST656 ST621 Fig. 45 When not in use, store handle in the handle holder. Stardance operable doors 1/31/01 Your First Fire It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to HV102 appear abnormal, call a Figure 48. If any of the flames Honeywell hi/lo knob service person. 4/5/99 djt Read these instructions carefully and familiarize yourself with the burner controls shown on Page 24. Locate the pilot assembly, Figure 46. Follow the lighting instructions on Page 24 exactly. During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within the first eight to ten hours, however, you can open a window to provide fresh air to alleviate the condition. PSE Pilot SIT Pilot ST624 handle holder Pilot and Burner Inspection 2/6/01 CO105c Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figure 48. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for assistance. Do not operate the heater until the pilot flame is correct. Follow regular maintenance procedures as described on Page 32. 20004188 Red Glow Fig. 48 CO105c Correct pilot and burner flame patterns. Pilot flame 4/10/00 djt LG157 23 Radiance Direct Vent/Natural Vent Gas Heater Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any fireplace • Do not touch any electric switch • Do not use any phone in your building • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the Fire Department C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion. D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water. Lighting Instructions 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level. 4. Open control access panel. 5. Push in gas control knob slightly and turn clockwise to “OFF”. OFF ON OFF 3/8" - 1/2" OFF 3 4 5 Euro SIT T LO PI ON 1 2 P OFF ilot PILOT 10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8. SIT NOVA Honeywell 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety inforFP1067 mation above. If you do not smell gas, go to the lighting instruction knobs next step. 3/9/01 djt 7. Remove glass door before lighting pilot. (See Glass Frame Removal section). 8. Visibly locate pilot by the main burner. 9. Turn knob on gas control counterclockwise to “PILOT”. • If knob does not pop up when released, stop and immediately call your service technician or gas supplier. FP1068 • If after several tries, the pilot will not stay lit, Lighting instructions turn the gas control knob to “OFF” and call your Pilots service technician or gas supplier. 11. Replace glass door. 12. Turn gas control knob to “ON” position. 13. For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting. 14. Turn on all electrical power to the fireplace. To Turn Off Gas To Heater 1. Turn the On/Off switch to Off position or set the thermostat to lowest setting. 2. Turn off all electric power to the fireplace if service is to be performed. 2424 3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to “OFF”. Do not force. 5. Close control access panel. 20004188 Radiance Direct Vent /Natural Vent Gas Heater Troubleshooting / Honeywell #8420 Gas Control System NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position. WARNING: REMOVE THE GLASS PANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK. SYMPTOM 1. Spark ignitor will not light 2. Pilot will not stay lit after carefully following the lighting instructions 3. Pilot lights, no gas to burner, valve knob ON, remote switch (rocker switch) ON POSSIBLE CAUSES CORRECTIVE ACTION A. Defective or misaligned electrode at the pilot Using a match, light pilot. If pilot lights, turn off pilot and push the ignitor button again. If pilot will not light, check gap at electrode and pilot - it should be 1/8” to have a strong spark. B. Defective ignitor (push button) Push piezo ignitor button. Check for spark at electrode and pilot. If there is no spark at the pilot, and electrode wire is properly connected, replace ignitor. A. Defective pilot generator (thermocouple) Check pilot flame. It must impinge on the thermocouple or thermopile. NOTE: This pilot burner assembly uses both a thermocouple and a thermopile. The thermocouple operates the pilot flame. Tighten the thermocouple. The thermopile operates the main valve (ON and OFF). Clean and/or adjust pilot for maximum flame impingement on thermocouple and thermopile. B. Defective automatic valve operator Turn valve knob to ‘Pilot’. Maintain flow to pilot; millivolt meter should read greater than 10mV. If the reading is okay and the pilot does not stay on, replace the gas valve. NOTE: An interrupter block (not supplied) must be used to conduct this test. A. Remote switch or wires defective Check rocker switch and wires for proper connection. Use jumper wires across terminals at rocker switch. If burner lights, replace rocker switch. If okay, use jumper wires across rocker switch wires at the valve; if burner lights, wires are faulty or connections are bad. B. Thermopile may not generate sufficient voltage 1. Be sure wire connections from thermopile at gas valve terminals are tight and thermopile is fully inserted into pilot bracket. 2. One of the rocker switch wires may be grounded. Remove rocker switch wires from valve terminals. If burner now stays lit, trace rocker switch wiring from ground. It may be grounded to the appliance or the gas supply line. 3. Check the thermopile with a millivolt meter. Take reading at thermopile (“TP” and “TP/TH”) terminals of gas valve. Should read 325 millivolts minimum while holding valve knob depressed in PILOT position and with rocker switch OFF. Replace faulty thermopile if reading is below specified minimum. 4. Frequent pilot outage 20004188 C. Plugged burner orifice Check burner orifices for debris, and remove. D. Defective automatic valve operator Turn knob to ON, place rocker switch to ON, millivolt meter should read greater than 10 mV. If the reading is okay and the burner does not light, replace the valve. A. Pilot flame may be too low or high, (blowing or lifting), causing the pilot to drop out B. Possible blockage of the vent terminal Clean and/or adjust pilot flame for maximum flame impingement on thermocouple and thermopile. Check the vent terminal for blockage. 25 Radiance Direct Vent/Natural Vent Gas Heater Instructions for RF Comfort Control Valve The Comfort Control valve allows remote control of temperature, fan and flame appearance. NOTE: The antenna should hang in free air away from grounded metal. Operation 1. If the manual switch is in remote position, switch it to LOCAL. (Fig. 49) 2. Turn the pilotstat knob counterclockwise from OFF to the PILOT position, push the knob down, and hold in position. The pilot valve opens and allows gas to flow to the pilot burner. 3. Push plunger on the piezo until the pilot burner is lit. When the pilot burner is lit, the LED on the control will come on after approximately 40 seconds and will provide 1 short blink continuously in the normal mode. When the light turns off which will be approximately 10 seconds after it has been continuously red, the receiver/valve is fully powered. Motor Top Cap 7. If the manual switch is in the LOCAL position, the valve will be at the highest fixed pressure setting and the fan will be at the highest fixed speed. The transmitter will control the fan only. Shut Off Procedure If the manual switch is in the REMOTE position, the transmitter can shut off the main burner and fan. However, the control is still on and a command from the transmitter can turn on the main burner or fan. To shut off the system, turn the pilotstat knob clockwise to the OFF position. This action closes the main gas and safety valves. The transmitter cannot turn on the main burner or fan. Transmitter Operation Off Mode In the OFF mode, the fireplace flame and fan are off, the display will show OFF and displays the room temperature. If the receiver is in REMOTE mode, the fireplace will shut off. Display Room Temperature Set Temperature Flame Height Level Fan Speed Level Countdown Timer Low Battery Flame Piezo Ignitor OFF • D LE LED Local/Remote Switch Pilotstat Knob Fig. 49 Comfort control valve. Plug Antenna FP1037 Increases Flame Height, Fan Speed Timer, or Set Point Down Decrease Flame, Fan Speed Timer or Set Point Fan FP1037 4. Release the knob. The shaft will move upward. The Honeywell pilot burner should now stay burning. If the pilot comfort valve burner goes out, repeatdjt step 2. 3/22/00 5. Turn the knob counterclockwise to the ON position. If the manual switch is in the LOCAL position, the main burner will turn on immediately. 6. ON the initial use of a transmitter, a recognition operation is required between the receiver/valve and transmitter. Change the switch from LOCAL to REMOTE. Press the fan or flame button on the transmitter within 30 seconds. The LED will blink indicating the transmitter will now work with the receiver/valve. If the switch continues in the REMOTE position, the transmitter will now control the main valve, flame modulation level and fan control. 2626 Up Countdown Timer REMOTE LOCAL O • N OT PIL Mode Auto On Off FP1039 Fig. 50 Transmitter diagram. On (Manual) Mode FP1039 comfort valve temperature, flame and fan In the ON mode, the room transmitter levels will be shown. MANUAL will appear next to both 3/27/00 djt the flame and fan icons. When the control is in the ON mode, the flame and fan levels, and delay timer are changed with the up and down buttons. To change the flame level, press the flame button followed by an arrow key. To change the fan level, press the fan key followed by an arrow key. Pushing the arrow key once will change the level by one unit. Delay Timer Mode The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 minutes. 20004188 Radiance Direct Vent /Natural Vent Gas Heater Auto Mode Pilot Assembly In the AUTO mode, the room temperature, set temperature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons. Blower When the control is in the AUTO mode, the main burner will turn on/off or modulate based on the heat needed to maintain the set temperature. The flame level will change automatically to optimize the heat output needed to maintain the set temperature. To change the set temperature, press the up or down key. Pushing a key once will change the temperature by one degree. Red White Change Between F/C Temperature Units Push the up and down arrow keys simultaneously for at least 3 seconds to toggle between Fahrenheit and Celsius units. Disable Thermostat Function To disable the thermostat function in the AUTO mode, push the time and down keys simultaneously for at least 3 seconds. To Change Batteries 1. Remove cover on the backside of the transmitter. Install 3 AAA batteries as shown and reattach cover. 2. Once steps 1-3 in OPERATION are completed, receiver/valve and transmitter are now ready. Press any button on transmitter for recognition process to occur between the receiver/valve and transmitter. 3. Use functions as described in TRANSMITTER section. Troubleshooting 1. Locate LED light on valve. 2. LED will blink after every valid command received by the transmitter; this is not an error. 3. Failure codes may occur anytime after pilot burner is lit. 4. Sequence is failure code followed by light not blinking for 30 seconds. Red White White Dots Antenna Fan Override During Auto Mode If a lower or higher fan speed is desired when operating in the AUTO mode, the fan speed can be overridden by pushing the fan button followed by the up or down key. Pushing a key once will change the fan level by one unit. In this mode “AUTO” is displayed next to the flame icon and “MANUAL” is displayed next to the fan icon. FAN In the AUTO mode, the fan speed will increase with increasing flame height or decrease with decreasing flame height. “AUTO” is displayed next to the flame and fan icons. FP1038 Valve (Bottom View) Fig. 51 Comfort Valve wiring diagram. 5. In the event of multiple failure codes, next failure FP1038 code follows previous failure code approximately comfort by valve 3 seconds. wiring diagram If an Error Code 3 is observed whiledjt performing the 3/24/00 testing, complete the following: 1. Make sure the spade connectors are pushed all the way on. If rhe Error Code 3 is still showing, then go to the next step. 2. Switch the front two thermopile leads with the back two. Be sure the white lead is connected to the spade with the white dot next to it. If the Error Code 3 is still showing, replace the thermopiles. If an Error Code 8 is observed while performing the testing, complete the following: 1. Confirm the valve is not in REMOTE mode. • If the valve is producing Error Code 8 and in REMOTE mode, the valve is defective and should be replaced. • If the valve is in LOCAL mode and producing Error Code 8, then go to the next step. 2. Slide the Remote/Local switch to REMOTE and teach the valve a transmitter (see item 6, page 32). The Error Code will clear itself after approximately 1.5 minutes and return to normal operation. LED Count Service Action 8 Replace valve 7 Confirm stepper motor connection exists 5 Confirm fan connection exists and works 4 Confirm gas type; jumper in place 3 Replace thermopiles 2 Turn fan ON NOTE: Some keys are not active. 20004188 27 Radiance Direct Vent/Natural Vent Gas Heater Comfort Valve System Control Sequence Of Operation With Transmitter Set manual switch to local or remote Five minute wait period Light pilot burner Did the LED stop blinking? No Review LED failure analysis. Release pilotstat knob. Yes Turn pilotstat knob from PILOT to ON. Cycle switch once and leave in remote. Press any key on transmitter for recognition operation. Local Path If manual switch is set to LOCAL, did main burner light and fan turn on? Yes Turn pilotstat knob to PILOT to turn off main burner. Turn pilotstat knob to OFF to turn valve completely off. Choose Manual or Remote path. Set switch to manual or remote. On Path Move switch from local to remote. Press any key on transmitter. Move switch back to local. If the manual switch is set to REMOTE, press the mode button to display “ON”. does transmitter control the main burner and fan? Move switch from manual to remote. Press any key on transmitter. Yes Does transmitter change levels of flame height, fan speed? No Yes Set levels of flame height and fan to “0” to shut off main burner and fan. Turn pilotstat knob to OFF to turn valve completely off. 2828 20004188 Radiance Direct Vent /Natural Vent Gas Heater Auto Path If the manual switch is set to REMOTE, press the mode button to display AUTO on the transmitter. Does the transmitter display the room and temperture setting? Move switch from LOCAL to REMOTE. Press any key within 30 seconds. Yes If the settings is above room temperture on the transmitter, does the main valve and fan turn on? No Yes If the settings is below room temperture on the transmitter, does the main valve and fan turn off? No Turn pilotstat knob to OFF to turn valve completely off. 20004188 29 Radiance Direct Vent/Natural Vent Gas Heater Fuel Conversion Instructions WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit. OFF O H PILOT ADJ ON L I PIL OT CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion. Gas Supply Inlet Main Gas Line ST226 Fig. 52 Attach the gas line to the left side of the valve. Conversion Precautions ST226 Before proceeding, turn control knob on valve to OFF attach gas line and turn gas supply OFF. TurndjtOFF any electricity that 12/8/99 may be going to the appliance. Remove Screws Rear Log Bracket Pilot Left & Right Log Bracket Assembly ST350 Fig. 53 Remove rear log bracket and left and right log bracket assembly. Burner Orifice Conversion 1. Hold the burner atST350 the right hand side and lift to clear the right burner leg. Then pull to the right to clear the Jefferson injectors on the left hand side. air shutter 2. Remove injector orifices from leftadj burner leg using 1/2” wrench. (Fig. 3/20/00 61) djt 3. Install conversion orifices. (Refer to Table 1) 4. Air shutter adjustment. The unit is shipped from the factory with the air shutter open 1”. For LP units only, the air shutter could be closed further. Refer to Table 2 for minimum air shutter opening. The air shutter is located on the bottom of the burner to the left. Unfasten the two nuts holding the shutter in place. Adjust the air shutter as needed according to Table 2. (Fig. 54) Refer to Table 2 Burner Conversion Procedure 1. Remove stove front. Lift stove front up and then swing bottom out and away to disengage from the stove body. (Page 32, Fig. 62) 2. Undo the right and left latches at the top of the glass frame. (Page 32, Fig. 63) 3. Pull the top edge of the glass and frame assembly away from the firebox face. Place the assembly out of the way on a flat, padded surface such as a counter protected by a towel. 4. Remove the logset from the firebox. 5. Remove the rear log bracket by loosening the screw and lifting the bracket up and away. (Fig. 53) 6. Remove the right and left log bracket assembly by unfastening the two screws which hold the burner in place. (Fig. 53) 3030 ST667 Fig. 54 Adjust air shutter according to Table 2. Models 3350, 3351, 3360 thru 3369 (R Models) Only ST667 Honeywell Valve 1. Remove cap from Hi-Lo RNVOD knob. This can be accomplished by lifting the plastic off the screw. (Fig. air cap shutter 55) converting 2. Remove the screw from from centerNG of Hi-Lo knob with to Lp small screwdriver turning counterclockwise. (Fig. 55) 6/4/01 djt 20004188 Radiance Direct Vent /Natural Vent Gas Heater E Cap Lift Open HI LO LO OF CO100 O Center Screw IL FP Hi-Lo Knob OT HI Fig. 55 Remove center screw CO100 from Hi-Lo knob. D Gas conversion knob 3. Insert blue painted screwHI-LO when 3/15/99 djt converting to natural gas and red painted screw when converting to LP. 4. Tighten screw (do not over tighten), replace cap. SIT 820 Valve 1. Using TORX T20 bit, remove and discard the three (3) pressure regulator mounting screws (A), pressure regulator tower (B) and the spring and diaphragm assembly (C). (Fig. 56) F FC108 Fig. 57 Replace regulator. FC108 SIT regulator conversion 10/03 Pilot Hood A B Pilot Bracket C CO105a Fig. 58 Remove pilot hood. Index Tab FP OF IL OT O FC107 Fig. 56 Remove mounting screws, pressure regulator tower and spring and diaphragm assembly. 2. Insure the rubber gasket (D) is properly positioned FC107 and install the new HI/LO pressure regulator assemSIT820 valvenew conversion bly to the valve using the screws (E) supplied with the kit. Tighten the10/03 screws securely. (Ref. torque = 25 in/lb) (Fig. 57) 3. Install the enclosed conversion label (F) to the valve body where it can easily be seen. (Fig. 57) Pilot Orifice Conversion 1. Locate pilot. (Fig. 53) 2. Replace pilot orifice. Pilot Type 1 (SIT Pilot) • Remove pilot hood by lifting up. (Fig. 58) Do not remove the snap ring to remove the pilot hood. NOTE: It is not necessary to remove the pilot tube for conversion. • Remove pilot orifice with allen wrench. (Fig. 59) 20004188 Allen Wrench Snap Ring CO105a gas conversion Pilot 1/28/00 djt CO106a Fig. 57 Remove pilot orifice. • Install the conversion orifice. • Reinstall pilot hood. Be sure to align hood with index tab. CO106a Pilot type 2 (Honeywell Pilot) • Loosen pilot hoodDV360/580 turning counterclockwise using a Conversion 7/16” wrench. (Fig.Gas 60) NOTE: You may use penPilot2 etrating oil to prevent pilot hood threads from seizing 1/28/00 djt up. • Remove pilot orifice with needlenose pliers. (Fig. 61) NOTE: Use a wrench to hold pilot tube in place while removing the orifice. • Install the conversion orifice. • Reinstall pilot hood and tighten until mark on pilot hood aligns with mark on pilot bracket. 31 Radiance Direct Vent/Natural Vent Gas Heater Motor Top Cap Center Plunger Pilot Hood OT PIL OFF • Red - LP CO105 Fig. 60 Remove pilot hood. (Your pilot may have a different appearance.) CO105 Gas ConversionPilot Orifice Pilot 2/15/99 djt CO106b Fig. 61 Remove pilot orifice. NOTE: Be sure burner leg remains at a 90° angle to firebox base after conversion. Models 3352, 3354, 3390 thru 3399 (RF Models) Only CO106a 1. Follow procedure for pilot type 2 to replace pilot orifice. Gas Conversion 2. Remove and replace plug on(Vermont) lower right hand side Pilot of the valve; Red for LP and Blue for NG. (Page 26, 7/19/99 djt Fig. 49) 3. Remove motor top cap. Depress and turn center plunger until arrow points to correct screw. Red for LP and Blue for NG. NOTE: Plunger will “snap” into NG position when arrow is close to blue screw. It will not “snap” at LP (Red) position. (Fig. 62) 4. Insure manifold pressure remains between 3.2” - 3.5” w.c. for NG and 9.5” - 10” w.c. for LP. To adjust the manifold pressure, for NG, using a torque #10 key turn the blue screw clockwise to increase the manifold pressure. Turn the screw counterclockwise to decrease the pressure. Use the red screw to adjust LP. 5. Replace motor top cap. FP1037b Fig. 62 Depress and turn center plunger. All Models 1. Replace burner. Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base. Lower the right FP1037b hand side down in to place. Make sure the burner is comfort valve are as far left as possible and the injector shoulders convert inside the burner. 3/6/01 djt NOTE: It is very critical to keep the left burner leg, which holds the injectors, at a 90° angle to the base. (Fig. 63) This keeps the orifices aligned with the tubes inside burner. Failure to do so could affect the flame appearance and performance of the unit. 2. Place conversion label on valve. 3. Reinstall the right and left log bracket assembly. 4. Reinstall the rear log bracket. 5. Replace logs. 6. Replace glass and stove front. Conversion is complete. Left Burner Leg Injector Orifices 90° ST353a Fig. 63 Remove and replace injector orifices. ST353a injector orifice replace 3/21/00 djt 3232 20004188 LE D Blue - NG Pilot Bracket REMOTE Index Marks LOCAL O • N Valve Radiance Direct Vent /Natural Vent Gas Heater Table 1. Injector Orifice Size Matrix Kit # 000-5002 Conversion to Natural Gas Part # Rear Part # Front #51 / .067” 30000449 #40 / .098” 20004263 Input (BTU/h) Minimum Maximum 25,000 35,000 000-5009 Kit # 000-5003 Conversion to LP Part # Rear Front #57 / .043” 20004587 #54 / .055” Part # 20000130 Input (BTU/h) Minimum Maximum 27,500 35,000 000-5010 Table 2. Air Shutter Adjustment Model RDVOD, RDVOD with Vermont Castings Draft Hood Z31D00 FSDHAG Natural Gas LP 1” Fully Closed Minimum rear injector air inlet openings. 20004188 33 Radiance Direct Vent/Natural Vent Gas Heater Maintenance Your Radiance Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly. Annual System Inspection Have the entire heater and venting system inspected annually by a qualified gas technician. Replace any worn or broken parts. Logset and Burner / Cleaning and Inspection Cleanliness is critical to the proper function of the heater. The logset and burner must all be kept free of dust and unobstructed by debris. Inspect these areas before each use and clean as necessary. 1. Turn the burner OFF and let the heater cool completely before cleaning. 2. Lift the Stove Front up and then swing the bottom out to disengage it from the heater shell. (Fig. 64) 3. Carefully remove the glass and frame assembly and place it out of the way on a flat, padded surface such as a counter protected by a towel. 4. Carefully inspect the Logs for damage. Contact your local dealer if any damage is evident. 5. Use a soft bristled brush to sweep dust or debris from the Logs, Pilot and Burner. Use care as the logs are fragile and susceptible to damage. 6. Replace the glass panel and frame assembly. 7. Replace the Stove Front. CAUTION TURN THE PILOT OFF BEFORE PAINTING. ALLOW THE HEATER TO COOL COMPLETELY BEFORE PAINTING. Cleaning the Glass WARNING: Allow the glass cool completely before attempting to clean. It will be necessary to clean the glass periodically. During start-up, condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with a non-ammonia household cleaner and warm water (we recommend gas fireplace glass cleaner). After that the glass should be cleaned two or three times during each heating season depending on the circumstances present. Clean glass after first two weeks of operation. Glass Replacement Replace glass only with CFM Corporation approved parts. Refer to Page 37 for Replacement Parts. Refer to Figure 65 and previous instructions for removal of the damaged glass frame. Care of Cast Iron An occasional dusting with a dry rag will help keep the painted surfaces looking new. Use high-temperature stove paints, available through your local dealer, to touch-up areas as needed. Clean areas to be painted with a wire brush and be sure to cover the logs, burner and valve assembly, glass and frame assembly. Apply the paint sparingly; two light coats of paint will give better results than a single heavy coat. Clean porcelain enamel surfaces with a soft, damp cloth. Do not use abrasive cleaning agents. If necessary, use only a cleaning agent formulated especially for use on porcelain enamel surfaces. ST139 Fig. 64 Remove the Stove Front. 3434 ST139 Radiance remove front 4/20/01 djt 20004188 Radiance Direct Vent /Natural Vent Gas Heater ST179 Fig. 66 Wrap the gasket material around the outside edge of the glass. ST141 Fig. 65 Release the latches to remove the glass frame. Gasket Replacement ST141 The Radiance Gas Heater uses a ‘tadpole’ type gasket pull glass latch 10/99 and the frame. In time, to seal between the glass panel this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer. Shut off the gas supply and allow the stove to cool. Wear safety goggles and a dust mask. 1. Remove the Front, Glass Frame and Glass Panel. (Figs. 62 & 63) Remove the old gasket. Use a razor blade to separate the glass and gasket from the frame, and to clean the glass of any remaining cement or bits of gasket. Use a cold chisel if necessary. 2. Determine the correct length of gasket by laying it out around the edge of the glass. Allow an extra 1 - 2” (25-50mm). Mark the spot to be cut. Use a utility knife. 3. Starting on a long edge, remove about 6” of the protective paper strip and apply the flat adhesive face of the gasket around the outside-facing edge of the panel. Continue around the panel, applying a bout 6” at a time and being careful to not stretch the material. Do not overlap the gasket ends. (Fig. 66) 4. Apply a thin bead of high temperature silicone rubber sealant along the inside corner of the glass frame, all around the perimeter. Place the flat gasketed side of the glass panel back into the steel frame. Pinch the rounded inside-facing gasket material to bulk it up. 5. Replace the glass frame and front panel as previously described. 20004188 Inspect the Vent System Annually ST179 glassinspected gasket detail Have the vent system annually by a qualified technician. Shut off the main gas supply before 11/99 inspecting the system. Both the inner exhaust pipe and the outer combustion supply pipe must be checked to confirm that they are unblocked and in good condition. Check the Gas Flame Regularly To ensure that the stove is operating properly, check the flames periodically to confirm that they match Figure 67. The flames will be blue during the first 15-20 minutes of operation, and will gradually turn to yellow after that. Do not use your stove if the flame pattern differs from that shown here. Contact your Vermont Castings dealer or a qualified technician for help. Red Glow LG157 Fig. 67 Correct flame pattern. LG157 Radiance logs flame 4/24/01 djt 35 Radiance Direct Vent/Natural Vent Gas Heater Wiring Diagrams OFF ON Thermopile Black On/Off Switch Wiring TP/TH BL Millivolt Gas Valve TP Black TH FAN POWER CORD Chassis Ground BL Thermopile Black St124b on/off/switch wiring 1/11/00 djt Strain Relief ON / OFF Rheostat Millivolt Gas Valve Black Snapstat ST124c WHT LK Fig. 68 On/off switch and optional thermostat circuit. B BLK GRN NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED WITH THE APPLIANCE, MUST BE REPLACED, IT MUSTSt124c BE REPLACED WITH TYPE SF-2, 200°C WIREThermostat OR ITS EQUIVALENT. Draft Hood BLK FAN JUNCTION BOX TP TH K Thermostat (Optional) Optional Thermostat Wiring TP/TH K GRN ST124b Thermostat (Optional) wiring 1/11/00 djt Chassis Ground RHEOSTAT / SNAPSTAT BOX ST153 Schematic Diagram MOTOR BLK BLK Vent Safety Switch ST153 rdv connections diag. BLK 10/99 WHT TH TP TH TP Fig. 69 Draft Hood Adapter (FSDHAG) wiring. Used on RN/RP models only. SNAPSTAT ON/OFF RHEOSTAT Gas Valve ST359 ST359 DRAFT HOOD WIRING 4/26/00 DJT GRN WHT BLK 3636 BLK WHT ST236 Fig. 70 Fan circuit. ST236 FK26 wiring diagram 12/99 20004188 Radiance Direct Vent /Natural Vent Gas Heater 2 1a 7 6 NT ME CE 8 7 3 4 5 1b 1c 10a,b 24 T OFF O H L PILOT ADJ OFF • 23 D ON • 16 REMOTE 15 T PILO LOCAL 12a 13 14 25 ON O LE I PIL 41 9 38 11a,b 19 12b 17 39 26 12c 22 27 18 44 45 28 49 20a,b 34 21a,b 32 33 29a,b, c,d 46 47 31 30 36 53 35 52 48 51 55a,b 37 50 56 CFM Corporation reserves the right to make changes in design, materials, 4188 specifications, prices and discontinue colors and products at any time, without notice. RDVOD parts 6/11/01 djt Radiance Direct Vent/Natural Vent Gas Heater (RDVOD) Models: 3225 thru 3232, 3350 thru 3354, 3360 thru 3369, 3390 thru 3399 Ref. 1. 1a. 1b. 1c. 2. 3. 4. 5. 6. Description RDVOD Gas Log Set, RDVOD Log, Right Rear - RDVOD Log, Left Rear - RDVOD Log, Right - RDVOD Gasker Cement, 3 oz. Tube Manifold Assembly Lava Rocks Burner Trim ON/OFF Switch - JDV Frame, Glass - RDV40 20004184 20004185 20004186 20004187 1206122 20003739 57897 30000874 1409112 20004188 37 Radiance Direct Vent/Natural Vent Gas Heater Radiance Direct Vent/Natural Vent Gas Heater (RDVOD) Models: 3225 thru 3232, 3350 thru 3354, 3360 thru 3369, 3390 thru 3399 (continued) Ref. Description 7. 8. 9. 10a. 10b. 11a. 11b. 12a. 13. Gasket, Glass Med. Knit - RDV40 Glass, GFP Firebox Ceramic Handle w/Insert LFTR Valve RN Honeywell VS8420E 2038 (Serial #’s up to 4939)* Valve RP Honeywell VS8420E 2020 (Serial #’s up to 4939)** Valve Gas Honeywell Convertible RFN RV8310E Valve Gas Honeywell Convertible RFP RV8310E Pilot Assembly 3Way N/DV RN 0.199.706 Pilot Assembly 3Way N/DV RP 0.199.703 PIlot PSE - NA175 Pilot PSE - LP175 Pilot Assembly 3Way DV/RFN CS3003A2009 Pilot Assembly 3Way DV/RFP CS3003A2017 Thermocouple 24” 14. 15. 16. Electrode Ignitor w/ Cable SIT24 Pilot Top Convertible Thermopile 18” RS 12b. 12c. 17. 18. 19. 20a. 20b. 21a. 21b. 22. 23. 24. 25. 26. 27. 28. 29a. 29b. 29c. 29d. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 41. 44. 45. 46. 3838 Nut Electrode SIT #0.974.144 Tubing Pilot w/ Fitting 1/8 x 24” Thermopile PSE for RF Pilots Pilot Orifice #62 - NG Top Convertible Pilot Orifice #35 - LP Top Convertible PIlot Orifice PSE RFN PIlot Orifice PSE RFP Antennae, Honeywell 395783-1 Front II, RDVOD Door Left - RDVOD Door Right - RDVOD Control Door, RDVOD Burner Housing Assembly Log Rear Bracket Orifice Hood (.043) - Front - LP Orifice Hood (.067”) - Front - NG Orifice Hood (.055”) - Rear - LP Orifice Hood (.098” ) - Rear - NG Gasket Base Pan Gasket Inner Base Pan Bracket, Right Log Bracket, Left Log Grate Decorative Burner Wire w/Straight Term 2 End 50” Transmitter Honeywell RF Sensor 2450 CMG-8184-0032 Damper Steel Handle/Screw Latch, Front Door - RDV Glass Frame Assembly - RDV40 Washer, Flat 1/4 - Blk. 266 x .629.064 CS, Hex Hd 1/4-20 x 5/8” - Blk Left End RDVOD 1203702 1601290 0004345 10001782 10001759 20003719 20003720 10002264 10002265 20001115 20001116 20002266 20002268 53373 7531137 10001297 10002266 51827 7533113 57886 10001296 20002400 10002268 10002269 20000908 20000907 20003561 Refer to Enamel Parts Chart Page 38 Refer to Enamel Parts Chart Page 38 Refer to Enamel Parts Chart Page 38 Refer to Enamel Parts Chart Page 38 20003526 20003577 20004587 30000449 20000130 20004263 20004287 20004286 20005259 20005258 20003536 10002582 20002047 10002013 30002720 30001249 5003075 1202473 1201372 Refer to Enamel Parts Chart Page 38 20004188 Radiance Direct Vent /Natural Vent Gas Heater Radiance Direct Vent/Natural Vent Gas Heater (RDVOD) Models: 3225 thru 3232, 3350 thru 3354, 3360 thru 3369, 3390 thru 3399 (continued) Ref. Description 47. 48. 49. 50. 51. 52. 53. 54. 55a. 55b. 56. 57. Right End Leg Control Door Handle Assembly Gasket, HE Door Top FK26 Fan Subassembly (RF Only) Grille, RDV40 Screen, Top RDV40 Valve Nova SIT820.662 RN (Serial #’s starting with 4940) Valve Nova SIT820.653 RP (Serial #’s starting with 4940) Ignitor Piezo w/Nut SIT Bracket Piezo Ignitor (not shown) RDVOD Refer to Enamel Parts Chart Page 38 Refer to Enamel Parts Chart Page 38 30002730 1203687 Refer to Enamel Parts Chart Page 38 30000879 1301195 1601970 20010563 20010645 52464 20010876 *When converting to SIT valve, must order RP275 **When converting to SIT valve, must order RP269 Fuel Conversion Kits Conversion Kit, NG to LP - RDVOD-RFN Conversion Kit, NG to LP - RDVOD-RN Conversion Kit, LP to NG - RDVOD-RFP Conversion Kit, LP to NG - RDVOD-RP Kit #000-5003 Kit #000-5010 Kit #000-5002 Kit #000-5009 Shell Enamel Parts - Radiance Direct Vent / Natural Vent Enamel Color Classic Biscuit Bordeaux Chestnut Brown Ebony Forest Green Midnight Blue Sand Suede Brown Vermont Cl. Green 20004188 Model Top 3360, 3365 3390, 3395 3225, 3229 3361, 3366 3391, 3396 3226, 3230 3227, 3231 3364, 3369 3394, 3399 3363, 3368 3393, 3398 3362, 3367 3392, 3397 3350, 3351 3352, 3354 3228, 3232 1301194 Left End 30001751 Right End 30001752 30003244 2321194 30003239 30001771 30003253 Front 30001376 Left Door 30001378 Right Door 30001377 Control Door 30001413 Leg (4) 30001753 30003238 30001770 30003240 30001416 30003242 30001418 30003241 30001417 30003243 30001419 30003245 30001772 30003248 30003247 30003249 30003251 30003250 30003252 30003254 30003262 2311194 30003257 30001780 30003256 30001779 30003258 30001428 30003260 30001430 30003259 30001429 30003261 30001431 30003263 30001781 2371194 30001777 30001776 30001424 30001426 30001425 30001427 30001778 1321194 30001774 30001773 30001420 30001422 30001421 30001423 30001775 30002546 30002512 30002511 30002514 30002516 30002515 30002517 30002518 30003271 30003266 30003265 30003267 30003269 30003268 30003270 30003272 39 Radiance Direct Vent/Natural Vent Gas Heater Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox temperature rises above and falls below a preset temperature. A rheostat provides for variable fan speeds. Specifications Screen Kit An optional screen, R40SK, for use with the operable doors is available to allow the doors to be left in the open position. Warming Shelf Warming shelves add versatility to your stove; they can be used to keep foods warm at mealtime. Model 115 Volt / 60Hz / .75 Amps Maintenance The fan itself does not require regular maintenance, however, periodic cleaning of the fan and the surrounding area is required. Installation Refer to Page 14 for installation instructions. Remote Controls The remote control allows you to turn the heater on or off from anywhere in the room. Refer to Page 35 for wiring diagrams. These remote controls are for use with RN/RP models. Model Functions Controlled RC1 RC2 IMTFK ON/OFF ON/OFF and Temperature Wall mounted thermostat control 1560 1555 1556 1557 1558 1562 1565 1566 1567 1568 Color Classic Black Biscuit Chestnut Brown Ebony Vermont Classic Green Sand Bordeaux Forest Green Midnight Blue Suede Brown The shelf installation is done in three stages. First you attach the shelf loosely to the stove, leaving the screws loose enough to allow final adjustments. Then, you position the shelf and adjust the brackets so the shelf fits correctly. Finally, you tighten the screws. Refer to the instructions included with each warming shelf for complete installation procedures. Decorative Rings 7” brass or charcoal gray rings are available to add a decorative touch to the exposed stove pipe. 4040 Model Description 7FSDRG/4 7FSDRP/4 7” Charcoal Gray Rings (4) 7” Polished Brass Rings (4) 20004188 Radiance Direct Vent /Natural Vent Gas Heater 20004188 41 Radiance Direct Vent/Natural Vent Gas Heater 4242 20004188 Radiance Direct Vent /Natural Vent Gas Heater LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations. EXTENDED LIFETIME WARRANTY The heat exchanger, where applicable, and combustion chamber of every Vermont Castings or Majestic gas product is warranted for life against through wall perforation. All appliances equipped with an Insta-Flame Ceramic Burner have limited lifetime coverage on the ceramic burner plaque. Warrantees are made to the original owner subject to proof of purchase and the conditions and limitations listed on this Warranty Document • • • • COMPONENT WARRANTY CAST IRON: All external and internal cast iron parts are warranted for a period of three years. Note: On porcelain enamel finished external parts and accessories The Company offers no Warranty on chipping of enamel surfaces. Inspect all product prior to accepting it for any damage to the enamel. The salt air environment of coastal areas or a high humidity environment can be corrosive to the porcelain enamel finish. These conditions can cause rusting of the cast iron beneath the porcelain enamel finish, which will cause the finish to flake off. Dye lot variations with replacement parts and/or accessories can occur and are not covered by warranty. GLASS DOORS: Glass doors are covered for a period of one year. Glass doors are not warranted for breakage due to misuse or accident. Glass doors are not covered for discoloration or burned in stains due to environmental issues, or improper cleaning and maintenance. BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar mix and masonry cleaners may corrode the brass finish. The Company will not be responsible for, nor will it warrant any brass parts which are damaged by external chemicals or down draft conditions. GAS VALVES: Gas valves are covered for a period of one year • • • • • • ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and mechanical components of the burner assembly are covered for one year. All steel tube burners are warranted for one year. ACCESSORIES: Unless otherwise noted all components and CFM Corporation company supplied accessories are covered for a period of one year. CONDITIONS AND LIMITATIONS • • • • This new Vermont Castings or Majestic product must be installed by a competent, authorized, service contractor. A licensed technician, as prescribed by the local jurisdiction must perform any installation/service work. It must be installed and operated at all times in accordance with the Installation and Operating instructions furnished with the product. Any alteration, willful abuse, accident, or misuse of the product shall nullify this warranty. This warranty is non-transferable, and is made to the original owner, provided that the purchase was made through an authorized supplier of the Company. The customer must pay for any Authorized Dealer in-home travel fees or service charges for in-home repair work. It is the dealers option whether the repair work will be done in the customer’s home or in the dealer’s shop. If upon inspection, the damage is found to be the fault of the manufacturer, repairs will be authorized at no charge to the customer parts and/or labor. 20004188 • Any part and/or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty, whichever is longest. This warranty is limited to the repair of or replacement of part(s) found to be defective in material or workmanship, provided that such part(s) have been subjected to normal conditions of use and service, after said defect is confirmed by the Company’s inspection. The company may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of the defective part(s) Any installation, labor, construction, transportation, or other related costs/expenses arising from defective part(s), repair, replacement, or otherwise of same, will not be covered by this warranty, nor shall the Company assume responsibility for same. Further, the Company will not be responsible for any incidental, indirect, or consequential damages except as provided by law. SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. All other warranties-expressed or implied- with respect to the product, its components and accessories, or any obligations/liabilities on the part of the Company are hereby expressly excluded. The Company neither assumes, nor authorizes any third party to assume on its behalf, any other liabilities with respect to the sale of this Vermont Castings or Majestic product The warranties as outlined within this document do not apply to chimney components or other non CFM Corporation accessories used in conjunction with the installation of this product.. Damage to the unit while in transit is not covered by this warranty but is subject to claim against the common carrier. Contact the dealer from whom you purchased your fireplace/stove (do not operate the appliance as this might negate the ability to process the claim with the carrier). The Company will not be responsible for: a) Down drafts or spillage caused by environmental conditions such as near-by trees, buildings, roof tops, hills, or mountains. b) Inadequate ventilation or negative air pressure caused by mechanical systems such as furnaces, fans, clothes dryers, etc. This warranty is void if: a) The fireplace has been operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals. b) The fireplace has been subjected to prolonged periods of dampness or condensation c) Any damages to the fireplace, combustion chamber, heat exchanger or other components due to water, or weather damage, which is the result of but not limited to, improper chimney/venting installation. d) Any alteration, willful abuse, accident, or misuse of the product has occurred. IF WARRANTY SERVICE IS NEEDED… 1) Contact your supplier. Make sure you have your warranty, your sales receipt, and the model/serial number of your CFM Corporation product. 2) DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF. 43 Efficiency Ratings Model RDVODRN RDVODRP RDVODRFN RDVODRPN EnerGuide Ratings Fireplace Efficiency (%) 60.7 60.7 60.7 60.7 CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www.cfmcorp.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 44 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:5180bbe8-ab1a-11db-a0b1-0003934a9da6 Create Date : 2005:02:01 10:27:51Z Metadata Date : 2007:01:23 14:45:46-05:00 Modify Date : 2007:01:23 14:45:46-05:00 Creator Tool : Adobe InDesign CS (3.0.1) Rendition Class : proof:pdf Document ID : adobe:docid:indd:9e28660d-75cd-11d9-83ad-992118222109 Derived From Instance ID : 9e28660c-75cd-11d9-83ad-992118222109 Derived From Document ID : adobe:docid:indd:faefbd90-7104-11d9-af8e-e846b5706c1a Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Reference Instance ID : uuid:c88cd874-9fb7-11da-a2d8-0003934a9da6, uuid:7cf0fdf0-98d5-11da-a61b-0003934a9da6, uuid:9691828e-6fa9-11d9-8b5f-0003934a9da6, uuid:c3de9406-6fa9-11d9-8b5f-0003934a9da6, uuid:5d81ee9e-6faa-11d9-8b5f-0003934a9da6, uuid:6433f64c-6faa-11d9-8b5f-0003934a9da6, uuid:6a79435f-6faa-11d9-8b5f-0003934a9da6, uuid:719394d0-6faa-11d9-8b5f-0003934a9da6, uuid:ff890cb0-6faa-11d9-8b5f-0003934a9da6, uuid:2b64893a-6fab-11d9-8b5f-0003934a9da6, uuid:70ba7384-ab19-11db-a0b1-0003934a9da6, uuid:c70dc2d4-18a4-11da-a6c5-0003934a9da6, uuid:d5dacf96-89da-11db-bb49-0003934a9da6, uuid:912190a4-6fad-11d9-8b5f-0003934a9da6, uuid:d9301ee7-6fad-11d9-8b5f-0003934a9da6, uuid:f861cec1-6fad-11d9-8b5f-0003934a9da6, uuid:e7803f4d-6fcb-11d9-8b5f-0003934a9da6, uuid:012cb928-86fc-11db-a3d5-0003934a9da6, uuid:e9b31f6b-6fcb-11d9-8b5f-0003934a9da6, uuid:e8651bbc-6faf-11d9-8b5f-0003934a9da6, uuid:e9a045a2-6fb1-11d9-8b5f-0003934a9da6, uuid:b5687f36-6fb2-11d9-8b5f-0003934a9da6, uuid:e5c52bf8-5dd8-11db-9898-0003934a9da6, uuid:e62c165a-5dd8-11db-9898-0003934a9da6, uuid:8a0abb2b-6fc3-11d9-8b5f-0003934a9da6, uuid:92854a28-6fc3-11d9-8b5f-0003934a9da6, uuid:fe3e8c64-6fc2-11d9-8b5f-0003934a9da6, uuid:154c25cc-6fc3-11d9-8b5f-0003934a9da6, uuid:75c1aa80-5d5e-11db-9cde-0003934a9da6, uuid:17740c48-cdfd-11d9-b6a8-0003934a9da6, uuid:0d5e43e1-d1cf-11d9-95f6-0003934a9da6 Manifest Reference Document ID : uuid:3e591d26-7ecd-11da-a401-0003934a9da6, uuid:7cf0f122-98d5-11da-a61b-0003934a9da6, uuid:96917466-6fa9-11d9-8b5f-0003934a9da6, uuid:c3de81b6-6fa9-11d9-8b5f-0003934a9da6, uuid:5d81e0d8-6faa-11d9-8b5f-0003934a9da6, uuid:6433e7fe-6faa-11d9-8b5f-0003934a9da6, uuid:6a7935c4-6faa-11d9-8b5f-0003934a9da6, uuid:719383ab-6faa-11d9-8b5f-0003934a9da6, uuid:ff88ff00-6faa-11d9-8b5f-0003934a9da6, uuid:2b647bb6-6fab-11d9-8b5f-0003934a9da6, uuid:db7c3022-8567-11db-b270-0003934a9da6, uuid:34aaa076-fe9f-11d9-ad11-0003934a9da6, uuid:b8b773c6-c57e-11da-aaf0-0003934a9da6, uuid:9121826b-6fad-11d9-8b5f-0003934a9da6, uuid:d9301152-6fad-11d9-8b5f-0003934a9da6, uuid:f861c062-6fad-11d9-8b5f-0003934a9da6, uuid:e7803145-6fcb-11d9-8b5f-0003934a9da6, uuid:012cac28-86fc-11db-a3d5-0003934a9da6, uuid:e9b31176-6fcb-11d9-8b5f-0003934a9da6, uuid:e8650dad-6faf-11d9-8b5f-0003934a9da6, uuid:e9a03659-6fb1-11d9-8b5f-0003934a9da6, uuid:b5686b75-6fb2-11d9-8b5f-0003934a9da6, uuid:602e972a-80f2-11d9-9596-0003934a9da6, uuid:520a980f-80f2-11d9-9596-0003934a9da6, uuid:8a0a9b8a-6fc3-11d9-8b5f-0003934a9da6, uuid:92853c4d-6fc3-11d9-8b5f-0003934a9da6, uuid:fe3e7b53-6fc2-11d9-8b5f-0003934a9da6, uuid:154c1840-6fc3-11d9-8b5f-0003934a9da6, uuid:311f3aba-5d5e-11db-bb09-0003934a9da6, uuid:177400dd-cdfd-11d9-b6a8-0003934a9da6, uuid:40218fca-715b-11d9-869d-0003934a9da6 Format : application/pdf Title : 2-4188 RDVOD.indd Trapped : False Creator : Adobe InDesign CS (3.0.1) Producer : Adobe PDF Library 6.0EXIF Metadata provided by EXIF.tools