WIMAN Systems WIMAN2A24 FHSS RF Modem User Manual Introduction to WIMAN technology

WIMAN Systems Inc FHSS RF Modem Introduction to WIMAN technology

Manual7

Download: WIMAN Systems WIMAN2A24 FHSS RF Modem User Manual Introduction to WIMAN technology
Mirror Download [FCC.gov]WIMAN Systems WIMAN2A24 FHSS RF Modem User Manual Introduction to WIMAN technology
Document ID132665
Application IDJ2XqCaXhfyP/RtOq7+Uz/g==
Document DescriptionManual7
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize230.98kB (2887229 bits)
Date Submitted2001-01-16 00:00:00
Date Available2001-01-19 00:00:00
Creation Date2001-01-16 09:17:37
Producing SoftwareAcrobat Distiller 4.05 for Windows
Document Lastmod2001-01-16 09:18:06
Document TitleIntroduction to WIMAN technology

Appendix A: WIMAN Hardware
8.2 Antenna systems
Different antenna systems can be used with the WIMAN radio
modem:
Part.-No.
750081
750040
750061
750062
Matchcode
AN-242MN360FMEM
AN-2416PL24-NF
AN-2424PF8-NF
AN-2416PL85-NF
Type
Omni
directional
Omni directional, 3° downtilt
planar
planar
paraflector
Planar
Gain [dBi]
8,5
16
24
16.5
Azimuth
[degrees]
360
360
75
27
85
Elevation
[degrees]
> 60
13
60
27
10
Height [cm]
12
43
11
28
61
127
Width [cm]
28
92
Depth [cm]
38
Weight [kg]
0.04
0.2
0.1
0.9
2.4
2.1
N/a
n/a
20
40
31
25
1.5
1.5
1.5
1.3
1.5
FME male
N female
SMA female
N female
N female
N female
Front/Back Ratio
[dB]
VSWR (max.)
Connector
750083
750001
AN-24AN-248MN360-NF3 8PL76-SMAF
71 / 90l
Appendix A: WIMAN Hardware
•
Omni directional antennas
Typically these antennas are used with WIMAN STAR stations.
AN-24-2MN360-FMEM
2 dBi
AN-24-8MN360-NF3
8 dBi, 3 deg downtilt
72 / 90
Appendix A: WIMAN Hardware
•
Planar antennas
These antennas are mainly used at the customer side in
connection with the WIMAN ACCESS. They can be used
also for point-to-point connections with WIMAN LINE
units.
AN-24-8PL76-SMAF
8.5 dBi
Picture
Azimuth Pattern
Elevation Pattern
AN-24-16PL24-NF
16 dBi
Picture
Azimuth Pattern
73 / 90l
Elevation Pattern
Appendix A: WIMAN Hardware
•
Paraflector antennas
These antennas were developed mainly for point-to-point
connections over long distances.
AN-24-24PF8-NF
24 dBi
Picture
Azimuth Pattern
74 / 90
Elevation Pattern
Appendix A: WIMAN Hardware
8.3 Hybrid-cable sets
Nachfolgend sind einige Anschlussbeispiele für die verschiedenen Hybridkabel aufgeführt. Eine genaue Beschreibung der einzelnen Hybridkabel ist in Kapitel 8.4 auf Seite 78 nachzulesen.
8.3.1
Standard Connection (Indoor) using Hybrid cable
Type 1
Hybrid-cable Type 1 is only used when a WIMAN is directly
connected to a Router (e.g. CISCO). This type of connection can
be used for devices, which are in close range to the Router (Indoor-Installation).
(H1-X21C-37)
SubD 15 F
SubD 9 F
DIN M
X.21
Config
24 V
WIMAN
SubD 37 F
Sample:
Frame Relay
Access Device
WIMAN Access
(incl. Planarantenna)
Hybridcable
Power supply
LAN
75 / 90l
Appendix A: WIMAN Hardware
8.3.2
Outdoor Installation using Hybrid cable Type 2 & 3
and Datacable
This connection is used when the WIMAN is installed on a rooftop or a radio tower and is synchronized among other WIMAN
devices. In addition a data cable (12x2) is needed.
(H2-X21C-25)
(H3-X21C-37)
SMA F
Syncronization
SubD 15 F
SubD 9 F
DIN M
X.21
Datacable
(max. 100m)
Config
WIMAN
12 x 2
24 V
SubD 25 M
SubD 25 F
SubD 25 F
SubD 25 M
SubD 37 F
Sample:
WIMAN Access
Outdoor-Set
(incl. Planar-Antenna
and Hybrid-Cable)
Datacable
(max. 100m)
Frame Relay
Access Device
HybridCable
Power Supply
LAN
76 / 90
Appendix A: WIMAN Hardware
8.3.3
Connection of a remote POP with WIMAN LINE and
STAR
This link is used for a remote Point Of Presence, if a WIMAN
STAR is connected via a WIMAN LINE link. Here the STAR
receives the synchronisation impulses likewise via the LINE
link.
(H4-X21C-37)
SMA F
Zeromodem X.21
Hybrid Cable Type 4
(NULL-X21C-15)
(H4-X21C-37)
SMA M
Syncronization
WIMAN
SubD 37 F
X.21
SMA M
SMA F
Syncronization
Syncronization
RG 316
SubD 15 M
SubD 15 F
SubD 15 F
SubD 15 M
X.21
WIMAN
X.21 Zeromodem
V.24 +
24 V
V.24 +
24 V
SubD 25 M
SubD 25 F
V.24 +
24 V
Extension cable
(max. 100m)
SubD 25 F
SubD 37 F
SubD 25 M
Hybrid Cable Type 2
12 x 2
(H2-X21C-25)
SubD 15 F
(not connectible)
Config
V.24 + 24 V
S 25 F
S 25 M
S 25 F
S 25 M
24 V
DIN M
SubD 15 F
(not connectible)
Config
24 V
8.3.4
SubD 9 F
SubD 9 F
DIN M
Connections when using the IP-routing functionality
Still being revised
77 / 90l
Appendix A: WIMAN Hardware
8.4 Hybridcable
In the following, all hybrid cables with their appropriate area of
application are described.
Note:
The 37-pin SubD link (female) is always attached to the 37-pin
SubD link (male) of the WIMAN.
8.4.1
Hybridcable used for X21-configurations
Zeromodemcable (NULL-C21-15)
Zeromodemcable for direct connection of 2 WIMAN devices. In
addition a Hybrid cable Type H4 is needed.
female
S 15
S 15
female
14 x 0,15 mm², shielded,
UV-resistant
1000 mm
Hybridcable Type1 (H1-X21C-37)
This hybrid cable is used with indoor installations and provides
the power connection, a direct link for a Frame Relay capable
Router as well as a configuration interface (RS-232).
female
with nut
female
with nut
11 x 0,15 mm², shielded
S 15
S9
3 x 0,15 mm², shielded
male
5 x 0,15 mm²
DIN Renk,
3 pin
300 mm
78 / 90
S 37
female
Appendix A: WIMAN Hardware
Hybridcable Type 2 (H2-X21C-25)
This Hybrid cable is being used as an internal termination cable
when installing a WIMAN on a readio-tower on on a rooftop.
The 25pin SubD-plug (male) is connected to the 12x2 Datacable, which leads from the WIMAN to the Router. All other
connectors are the same as on Hybrid cable type 1.
SubD 15
female
with nuts
SubD 9
female
with nuts
11 x 0,15 mm², shielded
S 15
SubD 25
male
3 x 0,15 mm², shielded
S9
S 25
5 x 0,15 mm²
300 mm
DIN Renk, 3 pin,
180 degrees, male
Hybrid cable Type 3 (H3-X21C-37)
This hybrid cable is attached with outdoor installations between
the WIMAN and the data cable (12x2). The SMA socket serves
for the link to the synchronisation bus, if several WIMAN devices are mounted in direct proximity.
6 mm
2 mm
RG 316
SMA
female
SubD 25
male
with nuts
SubD 37
female
S 37
S 25
23 x 0,15 mm², shielded, paired
400 mm
Date: 27. June 2000
79 / 90l
Appendix A: WIMAN Hardware
Hybrid cable Type 4 (H4-X21C-37)
This hybrid cable is used with a Peer to Peer structure of a remote POP. For this an additional NULL-X21C-15 cable, a synchronisation bus, a data cable (12x2) and a hybrid cable Typ2
becomes necessary (schematic structure see further above.)
female
male
with nut
SMA
RG 316
S 15
13 x 0,15 mm²,
shielded
male
with nut
S 25
S 37
9 x 0,15 mm², shielded
400 mm
80 / 90
female
Appendix A: WIMAN Hardware
8.4.2
Hybrid cable when using the IP-routing-functionality
RJ45-Connectionbox (HA-ETH-45)
This link box is attached between the Ethernet cable of the local
network and the hybrid cable H3-eth-37ext. Into the box the current supply link of the WIMAN, which is connected to the
power pack, is integrated.
RJ 45
female
RJ 45
female
Hybrid cable Ethernet 1 (H1-ETH-37)
This Ethernet hybrid cable is used for indoor installations and
provides the power connection, a direct link to the local network
(over Ethernet cable) and a configuration interface (RS-232).
6 mm
2 mm
4 x 0,15 mm², shielded, paired
RJ45,
female
3 x 0,15 mm², shielded
SubD 9
female
with nuts
SubD 37
female
5 x 0,15 mm²
DIN Renk, 3 pin,
180 degrees, male
81 / 90l
300 mm
Date: 10. July 2000
Appendix A: WIMAN Hardware
Hybrid cable Ethernet 2 (H2-ETH-25)
This hybrid cable is used as internal terminal cable with radio
tower installations or installation of the WIMAN on a rooftop.
The 25-pin SubD (male) link is connected to the data cable
(12x2), which leads from the WIMAN (outdoor) to the inward.
The further interfaces correspond to those of the hybrid cable
Type Ethernet 1.
6 mm
2 mm
4 x 0,15 mm², shielded, paired
SubD 25
male
RJ45,
female
SubD 9
female
with nuts
3 x 0,15 mm², shielded
S9
S 25
5 x 0,15 mm²
300 mm
DIN Renk, 3 pin,
180 degrees, male
Date: 10. July 2000
Hybrid cable Ethernet 3 (H3-ETH-37EXT)
This hybrid cable serves for the link of the WIMAN to the local
Ethernet. The current supply lines of the WIMAN are already
integrated in this cable. This cable can be used only together
with the link port HA-ETH-45.
Cat 5, STP
S 37
RJ45 male
incl. protective cap
25 m
82 / 90
SubD 37
female
Appendix B: Technical data
Appendix B: Technical data
Product outline
WIMAN Star, Access high-speed transfer in point-tomulti-point mode
WIMAN Line
flexible point-to-point transfer
Radio
Frequency range
2.400 - 2.4835 GHz
Type of modulation
Spread Spectrum Frequency
Hopping 2-FSK, 4-FSK
Number of channels
80, non-overlapping
Wireless interface
1 Mbps, 2-FSK
2 Mbps, 4-FSK
Transmitting power
100 mW (ETSI-Version) (E.I.R.P.)
4 W
(FCC-Version) (E.I.R.P.)
(650 mW max output-power @
RF-connector)
Transfer capacity
256 KBps @ 2-FSK
512 KBps @ 4-FSK
Max. input-level
0 dBm
Recipientsensitivity
-94 dBm @ 2-FSK
-88 dBm @ 4-FSK
Range
up to 5 km (ETSI-Version with planar array antennas)
up to 25 mi (FCC-Version)
RF-connector
SMA plug connector
RF interface
Configurable block-repetition
CRC-based error correction
In-slot acknowledgement
Device-specific data encryption
Data-interface
Synchronous
83 / 90l
X.21 / V.35 (optional) max. 2 Mbps
Appendix B: Technical data
Protocols
Point-to-point-mode
Synchronous
Transparent (HDLCframe structure)
Point-to-Multipoint-mode
Synchronous operation
Frame Relay Packet Switching
Antennas
Mobile antenna
Omnidirectional 2 dBi
Fixed antennas
Omnidirectional 8 dBi
Planar 8.5 dBi
Planar 16 dBi
Paraflector 24 dBi
Mass & weights (without antennas)
WIMAN-device
176 x 110 x 40 mm, 1050 g
Outdoor box
300 x 190 x 85 mm, 2200 g
General
Voltage supply
12 – 26 V =; max. 10 W
110 – 230 V, 50 -60 Hz~
Temperature range
-20°C - +55°C
Humidity
100 %, not condensing
IP enclosure
IP63, mounted in security housing
Display
3 LEDs, two-colored
Administration
Remote looptest
SNMP-based status-query and error signaling
Network access via TCP / IP, password protected
Software-update via TFTP
Individual bandwidth management
84 / 90
Appendix C: Pin-allocation of the Datacables
10
Appendix C: Pin-allocation of the Datacables
10.1 WIMAN Datacable (10 x 2)
Pin
Wire color (1. line)
10
11
12
13
White/Grey
White/Yellow
Yellow/Brown
White
Brown
Grey/Brown
Green
Yellow
Pink
Grey
Table 7
Pin
14
15
16
17
18
19
20
21
22
23
24
25
Wire color (2. line)
White/Green
Brown/Green
Pink/Brown
White/Pink
Grey/Pink
Red/Blue
Black
Purple
Red
Blue
WIMAN data cable (10 x 2), pin assortment
Attention:
Provide a correct grounding of the data cable screen.
Paired-wire
10
Shield
Table 8
Wire color
Pin number
White
Green
Grey
Blue
Black
Grey/Pink
White/Green
White/Yellow
White/Grey
White/Pink
12
25
21
18
14
17
Shield
Wire color
Brown
Yellow
Pink
Red
Purple
Red/Blue
Brown/Green
Yellow/Brown
Grey/Brown
Pink/Brown
Pin number
10
11
24
22
19
15
16
WIMAN data cable (10 x 2) paired-wire assortment
85 / 90l
Appendix C: Pin-allocation of the Datacables
10.2 WIMAN Datacable (12 x 2)
Pin
10
11
12
13
Wire color (1. line)
White/Grey
Grey/Brown
White/Yellow
Yellow/Brown
White
Brown
White/Blue
Brown/Blue
Green
Yellow
Pink
Grey
Table 9
Pin
14
15
16
17
18
19
20
21
22
23
24
25
Wire color (2. line)
White/Green
Brown/Green
Pink/Brown
White/Pink
Grey/Pink
Red/Blue
White/Red
Black
Purple
Brown/Red
Red
Blue
WIMAN data cable (12 x 2) pin assortment
Attention:
Provide a correct grounding of the data cable screen.
Paired-wire
10
11
12
Screen
Wire color
Pin number
Wire color
Pin number
White
Green
Grey
Blue
Black
Grey/Pink
White/Green
White/Yellow
White/Grey
White/Pink
White/Blue
White/Red
12
25
21
18
14
17
Brown
Yellow
Pink
Red
Purple
Red/Blue
Brown/Green
Yellow/Brown
Grey/Brown
Pink/Brown
Brown/Blue
Brown/Red
10
11
24
22
19
15
16
Screen
Table 10 WIMAN data cable (12 x 2) Paired-wire assortment
86 / 90
Fehler! Verweisquelle konnte nicht gefunden werden.
Appendix D: Alphabetical list of instructions
11
Appendix D: Alphabetical list of instructions
Instruction
 
Checkcfg
Clear
Clear stat 
Config
Del config
Del 
Del passwd console
Enable
Exit
Export
Help
Help 
Passwd console
Passwd console crypt
Passwd enable
Passwd enable crypt
Reset
Reset config
Restore
Save
Show
Show 
Stat 
Swupdate
Applicable in command
mode starting from authorization level
Applicable in configuration mode starting from
authorization level
1 (configuration password)
Remarks
No help available
No help available
No help available
No help available
No help available
Table 11 alphabetical list of instructions
87 / 90l
12 Index
12
Index
Will be created later
88 / 90
13 Index of figures
13
Index of figures
Figure 1
Figure 2
Figure 3
Figure 4
Figure 6
Figure 7
Figure 8
Figure 9
Point-to-Point connection using WIMAN LINE.........................................10
wireless access networks with WIMAN STAR and WIMAN ACCESS .....11
Standard Frame Relay applications.........................................................12
Diagram of the different operating modes ...............................................15
exported configuration file .......................................................................28
Help display output ..................................................................................30
the statistics assistance display...............................................................31
arrangement of equipment for the configuration of the WIMAN radio
modem .............................................................................................34
Frame Relay connections with the WIMAN ..........................................58
Simple WIMAN Network with CISCO-Router........................................62
front side of the WIMAN radio modem..................................................70
rear side of the WIMAN radio modem ..................................................70
Figure 10
Figure 11
Figure 12
Figure 13
89 / 90l
14 Index of tables
14
Index of tables
Table 1
Table 2
Table 3
Table 4
Table 5
Table 6
Table 7
Table 8
Table 9
Table 10
Table 11
parameters of an extended point-to-point connection (connection 1) ..... 54
parameter of an extended point-to-point connection (connection 2) ....... 54
Structure of the 2 Byte long address array.............................................. 59
NodeId with 2-Byte-Frame Relay address array ..................................... 60
DLCI allocation in connection with 2-Byte-address array........................ 61
bit sequence for different DLCI identifiers ............................................... 61
WIMAN data cable (10 x 2), pin assortment............................................ 85
WIMAN data cable (10 x 2) paired-wire assort-ment .............................. 85
WIMAN data cable (12 x 2) pin assortment............................................. 86
WIMAN data cable (12 x 2) Paired-wire assortment ............................ 86
alphabetical list of instructions ............................................................. 87
90 / 90

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Modify Date                     : 2001:01:16 09:18:06+01:00
Create Date                     : 2001:01:16 09:17:37+01:00
Title                           : Introduction to WIMAN technology.
Creator                         : 
Producer                        : Acrobat Distiller 4.05 for Windows
Page Count                      : 20
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NB9WIMAN2A24

Navigation menu