WIMAN Systems WIMAN2A24 FHSS RF Modem User Manual Introduction to WIMAN technology
WIMAN Systems Inc FHSS RF Modem Introduction to WIMAN technology
Contents
Manual7
Appendix A: WIMAN Hardware 8.2 Antenna systems Different antenna systems can be used with the WIMAN radio modem: Part.-No. 750081 750040 750061 750062 Matchcode AN-242MN360FMEM AN-2416PL24-NF AN-2424PF8-NF AN-2416PL85-NF Type Omni directional Omni directional, 3° downtilt planar planar paraflector Planar Gain [dBi] 8,5 16 24 16.5 Azimuth [degrees] 360 360 75 27 85 Elevation [degrees] > 60 13 60 27 10 Height [cm] 12 43 11 28 61 127 Width [cm] 28 92 Depth [cm] 38 Weight [kg] 0.04 0.2 0.1 0.9 2.4 2.1 N/a n/a 20 40 31 25 1.5 1.5 1.5 1.3 1.5 FME male N female SMA female N female N female N female Front/Back Ratio [dB] VSWR (max.) Connector 750083 750001 AN-24AN-248MN360-NF3 8PL76-SMAF 71 / 90l Appendix A: WIMAN Hardware • Omni directional antennas Typically these antennas are used with WIMAN STAR stations. AN-24-2MN360-FMEM 2 dBi AN-24-8MN360-NF3 8 dBi, 3 deg downtilt 72 / 90 Appendix A: WIMAN Hardware • Planar antennas These antennas are mainly used at the customer side in connection with the WIMAN ACCESS. They can be used also for point-to-point connections with WIMAN LINE units. AN-24-8PL76-SMAF 8.5 dBi Picture Azimuth Pattern Elevation Pattern AN-24-16PL24-NF 16 dBi Picture Azimuth Pattern 73 / 90l Elevation Pattern Appendix A: WIMAN Hardware • Paraflector antennas These antennas were developed mainly for point-to-point connections over long distances. AN-24-24PF8-NF 24 dBi Picture Azimuth Pattern 74 / 90 Elevation Pattern Appendix A: WIMAN Hardware 8.3 Hybrid-cable sets Nachfolgend sind einige Anschlussbeispiele für die verschiedenen Hybridkabel aufgeführt. Eine genaue Beschreibung der einzelnen Hybridkabel ist in Kapitel 8.4 auf Seite 78 nachzulesen. 8.3.1 Standard Connection (Indoor) using Hybrid cable Type 1 Hybrid-cable Type 1 is only used when a WIMAN is directly connected to a Router (e.g. CISCO). This type of connection can be used for devices, which are in close range to the Router (Indoor-Installation). (H1-X21C-37) SubD 15 F SubD 9 F DIN M X.21 Config 24 V WIMAN SubD 37 F Sample: Frame Relay Access Device WIMAN Access (incl. Planarantenna) Hybridcable Power supply LAN 75 / 90l Appendix A: WIMAN Hardware 8.3.2 Outdoor Installation using Hybrid cable Type 2 & 3 and Datacable This connection is used when the WIMAN is installed on a rooftop or a radio tower and is synchronized among other WIMAN devices. In addition a data cable (12x2) is needed. (H2-X21C-25) (H3-X21C-37) SMA F Syncronization SubD 15 F SubD 9 F DIN M X.21 Datacable (max. 100m) Config WIMAN 12 x 2 24 V SubD 25 M SubD 25 F SubD 25 F SubD 25 M SubD 37 F Sample: WIMAN Access Outdoor-Set (incl. Planar-Antenna and Hybrid-Cable) Datacable (max. 100m) Frame Relay Access Device HybridCable Power Supply LAN 76 / 90 Appendix A: WIMAN Hardware 8.3.3 Connection of a remote POP with WIMAN LINE and STAR This link is used for a remote Point Of Presence, if a WIMAN STAR is connected via a WIMAN LINE link. Here the STAR receives the synchronisation impulses likewise via the LINE link. (H4-X21C-37) SMA F Zeromodem X.21 Hybrid Cable Type 4 (NULL-X21C-15) (H4-X21C-37) SMA M Syncronization WIMAN SubD 37 F X.21 SMA M SMA F Syncronization Syncronization RG 316 SubD 15 M SubD 15 F SubD 15 F SubD 15 M X.21 WIMAN X.21 Zeromodem V.24 + 24 V V.24 + 24 V SubD 25 M SubD 25 F V.24 + 24 V Extension cable (max. 100m) SubD 25 F SubD 37 F SubD 25 M Hybrid Cable Type 2 12 x 2 (H2-X21C-25) SubD 15 F (not connectible) Config V.24 + 24 V S 25 F S 25 M S 25 F S 25 M 24 V DIN M SubD 15 F (not connectible) Config 24 V 8.3.4 SubD 9 F SubD 9 F DIN M Connections when using the IP-routing functionality Still being revised 77 / 90l Appendix A: WIMAN Hardware 8.4 Hybridcable In the following, all hybrid cables with their appropriate area of application are described. Note: The 37-pin SubD link (female) is always attached to the 37-pin SubD link (male) of the WIMAN. 8.4.1 Hybridcable used for X21-configurations Zeromodemcable (NULL-C21-15) Zeromodemcable for direct connection of 2 WIMAN devices. In addition a Hybrid cable Type H4 is needed. female S 15 S 15 female 14 x 0,15 mm², shielded, UV-resistant 1000 mm Hybridcable Type1 (H1-X21C-37) This hybrid cable is used with indoor installations and provides the power connection, a direct link for a Frame Relay capable Router as well as a configuration interface (RS-232). female with nut female with nut 11 x 0,15 mm², shielded S 15 S9 3 x 0,15 mm², shielded male 5 x 0,15 mm² DIN Renk, 3 pin 300 mm 78 / 90 S 37 female Appendix A: WIMAN Hardware Hybridcable Type 2 (H2-X21C-25) This Hybrid cable is being used as an internal termination cable when installing a WIMAN on a readio-tower on on a rooftop. The 25pin SubD-plug (male) is connected to the 12x2 Datacable, which leads from the WIMAN to the Router. All other connectors are the same as on Hybrid cable type 1. SubD 15 female with nuts SubD 9 female with nuts 11 x 0,15 mm², shielded S 15 SubD 25 male 3 x 0,15 mm², shielded S9 S 25 5 x 0,15 mm² 300 mm DIN Renk, 3 pin, 180 degrees, male Hybrid cable Type 3 (H3-X21C-37) This hybrid cable is attached with outdoor installations between the WIMAN and the data cable (12x2). The SMA socket serves for the link to the synchronisation bus, if several WIMAN devices are mounted in direct proximity. 6 mm 2 mm RG 316 SMA female SubD 25 male with nuts SubD 37 female S 37 S 25 23 x 0,15 mm², shielded, paired 400 mm Date: 27. June 2000 79 / 90l Appendix A: WIMAN Hardware Hybrid cable Type 4 (H4-X21C-37) This hybrid cable is used with a Peer to Peer structure of a remote POP. For this an additional NULL-X21C-15 cable, a synchronisation bus, a data cable (12x2) and a hybrid cable Typ2 becomes necessary (schematic structure see further above.) female male with nut SMA RG 316 S 15 13 x 0,15 mm², shielded male with nut S 25 S 37 9 x 0,15 mm², shielded 400 mm 80 / 90 female Appendix A: WIMAN Hardware 8.4.2 Hybrid cable when using the IP-routing-functionality RJ45-Connectionbox (HA-ETH-45) This link box is attached between the Ethernet cable of the local network and the hybrid cable H3-eth-37ext. Into the box the current supply link of the WIMAN, which is connected to the power pack, is integrated. RJ 45 female RJ 45 female Hybrid cable Ethernet 1 (H1-ETH-37) This Ethernet hybrid cable is used for indoor installations and provides the power connection, a direct link to the local network (over Ethernet cable) and a configuration interface (RS-232). 6 mm 2 mm 4 x 0,15 mm², shielded, paired RJ45, female 3 x 0,15 mm², shielded SubD 9 female with nuts SubD 37 female 5 x 0,15 mm² DIN Renk, 3 pin, 180 degrees, male 81 / 90l 300 mm Date: 10. July 2000 Appendix A: WIMAN Hardware Hybrid cable Ethernet 2 (H2-ETH-25) This hybrid cable is used as internal terminal cable with radio tower installations or installation of the WIMAN on a rooftop. The 25-pin SubD (male) link is connected to the data cable (12x2), which leads from the WIMAN (outdoor) to the inward. The further interfaces correspond to those of the hybrid cable Type Ethernet 1. 6 mm 2 mm 4 x 0,15 mm², shielded, paired SubD 25 male RJ45, female SubD 9 female with nuts 3 x 0,15 mm², shielded S9 S 25 5 x 0,15 mm² 300 mm DIN Renk, 3 pin, 180 degrees, male Date: 10. July 2000 Hybrid cable Ethernet 3 (H3-ETH-37EXT) This hybrid cable serves for the link of the WIMAN to the local Ethernet. The current supply lines of the WIMAN are already integrated in this cable. This cable can be used only together with the link port HA-ETH-45. Cat 5, STP S 37 RJ45 male incl. protective cap 25 m 82 / 90 SubD 37 female Appendix B: Technical data Appendix B: Technical data Product outline WIMAN Star, Access high-speed transfer in point-tomulti-point mode WIMAN Line flexible point-to-point transfer Radio Frequency range 2.400 - 2.4835 GHz Type of modulation Spread Spectrum Frequency Hopping 2-FSK, 4-FSK Number of channels 80, non-overlapping Wireless interface 1 Mbps, 2-FSK 2 Mbps, 4-FSK Transmitting power 100 mW (ETSI-Version) (E.I.R.P.) 4 W (FCC-Version) (E.I.R.P.) (650 mW max output-power @ RF-connector) Transfer capacity 256 KBps @ 2-FSK 512 KBps @ 4-FSK Max. input-level 0 dBm Recipientsensitivity -94 dBm @ 2-FSK -88 dBm @ 4-FSK Range up to 5 km (ETSI-Version with planar array antennas) up to 25 mi (FCC-Version) RF-connector SMA plug connector RF interface Configurable block-repetition CRC-based error correction In-slot acknowledgement Device-specific data encryption Data-interface Synchronous 83 / 90l X.21 / V.35 (optional) max. 2 Mbps Appendix B: Technical data Protocols Point-to-point-mode Synchronous Transparent (HDLCframe structure) Point-to-Multipoint-mode Synchronous operation Frame Relay Packet Switching Antennas Mobile antenna Omnidirectional 2 dBi Fixed antennas Omnidirectional 8 dBi Planar 8.5 dBi Planar 16 dBi Paraflector 24 dBi Mass & weights (without antennas) WIMAN-device 176 x 110 x 40 mm, 1050 g Outdoor box 300 x 190 x 85 mm, 2200 g General Voltage supply 12 – 26 V =; max. 10 W 110 – 230 V, 50 -60 Hz~ Temperature range -20°C - +55°C Humidity 100 %, not condensing IP enclosure IP63, mounted in security housing Display 3 LEDs, two-colored Administration Remote looptest SNMP-based status-query and error signaling Network access via TCP / IP, password protected Software-update via TFTP Individual bandwidth management 84 / 90 Appendix C: Pin-allocation of the Datacables 10 Appendix C: Pin-allocation of the Datacables 10.1 WIMAN Datacable (10 x 2) Pin Wire color (1. line) 10 11 12 13 White/Grey White/Yellow Yellow/Brown White Brown Grey/Brown Green Yellow Pink Grey Table 7 Pin 14 15 16 17 18 19 20 21 22 23 24 25 Wire color (2. line) White/Green Brown/Green Pink/Brown White/Pink Grey/Pink Red/Blue Black Purple Red Blue WIMAN data cable (10 x 2), pin assortment Attention: Provide a correct grounding of the data cable screen. Paired-wire 10 Shield Table 8 Wire color Pin number White Green Grey Blue Black Grey/Pink White/Green White/Yellow White/Grey White/Pink 12 25 21 18 14 17 Shield Wire color Brown Yellow Pink Red Purple Red/Blue Brown/Green Yellow/Brown Grey/Brown Pink/Brown Pin number 10 11 24 22 19 15 16 WIMAN data cable (10 x 2) paired-wire assortment 85 / 90l Appendix C: Pin-allocation of the Datacables 10.2 WIMAN Datacable (12 x 2) Pin 10 11 12 13 Wire color (1. line) White/Grey Grey/Brown White/Yellow Yellow/Brown White Brown White/Blue Brown/Blue Green Yellow Pink Grey Table 9 Pin 14 15 16 17 18 19 20 21 22 23 24 25 Wire color (2. line) White/Green Brown/Green Pink/Brown White/Pink Grey/Pink Red/Blue White/Red Black Purple Brown/Red Red Blue WIMAN data cable (12 x 2) pin assortment Attention: Provide a correct grounding of the data cable screen. Paired-wire 10 11 12 Screen Wire color Pin number Wire color Pin number White Green Grey Blue Black Grey/Pink White/Green White/Yellow White/Grey White/Pink White/Blue White/Red 12 25 21 18 14 17 Brown Yellow Pink Red Purple Red/Blue Brown/Green Yellow/Brown Grey/Brown Pink/Brown Brown/Blue Brown/Red 10 11 24 22 19 15 16 Screen Table 10 WIMAN data cable (12 x 2) Paired-wire assortment 86 / 90 Fehler! Verweisquelle konnte nicht gefunden werden. Appendix D: Alphabetical list of instructions 11 Appendix D: Alphabetical list of instructions InstructionCheckcfg Clear Clear stat Config Del config Del Del passwd console Enable Exit Export Help Help Passwd console Passwd console crypt Passwd enable Passwd enable crypt Reset Reset config Restore Save Show Show Stat Swupdate Applicable in command mode starting from authorization level Applicable in configuration mode starting from authorization level 1 (configuration password) Remarks No help available No help available No help available No help available No help available Table 11 alphabetical list of instructions 87 / 90l 12 Index 12 Index Will be created later 88 / 90 13 Index of figures 13 Index of figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 6 Figure 7 Figure 8 Figure 9 Point-to-Point connection using WIMAN LINE.........................................10 wireless access networks with WIMAN STAR and WIMAN ACCESS .....11 Standard Frame Relay applications.........................................................12 Diagram of the different operating modes ...............................................15 exported configuration file .......................................................................28 Help display output ..................................................................................30 the statistics assistance display...............................................................31 arrangement of equipment for the configuration of the WIMAN radio modem .............................................................................................34 Frame Relay connections with the WIMAN ..........................................58 Simple WIMAN Network with CISCO-Router........................................62 front side of the WIMAN radio modem..................................................70 rear side of the WIMAN radio modem ..................................................70 Figure 10 Figure 11 Figure 12 Figure 13 89 / 90l 14 Index of tables 14 Index of tables Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Table 10 Table 11 parameters of an extended point-to-point connection (connection 1) ..... 54 parameter of an extended point-to-point connection (connection 2) ....... 54 Structure of the 2 Byte long address array.............................................. 59 NodeId with 2-Byte-Frame Relay address array ..................................... 60 DLCI allocation in connection with 2-Byte-address array........................ 61 bit sequence for different DLCI identifiers ............................................... 61 WIMAN data cable (10 x 2), pin assortment............................................ 85 WIMAN data cable (10 x 2) paired-wire assort-ment .............................. 85 WIMAN data cable (12 x 2) pin assortment............................................. 86 WIMAN data cable (12 x 2) Paired-wire assortment ............................ 86 alphabetical list of instructions ............................................................. 87 90 / 90
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Modify Date : 2001:01:16 09:18:06+01:00 Create Date : 2001:01:16 09:17:37+01:00 Title : Introduction to WIMAN technology. Creator : Producer : Acrobat Distiller 4.05 for Windows Page Count : 20EXIF Metadata provided by EXIF.tools