Wave Wireless Networking SLSC5800 Point to Point Spread Spectrum Transceiver User Manual Manual
Wave Wireless Networking Point to Point Spread Spectrum Transceiver Manual
Manual
SC5800 Digital Radio User Manual for 5.725 to 5.850-GHz Frequency Band for Version 2 Document Number: 862-01881: Issue 7.1 Last Revised: September 17, 2001 Wave Wireless Networking Division of SPEEDCOM Wireless 7020 Professional Parkway East Sarasota, FL 34240 941-358-9283 941-355-0219 FAX www.wavewireless.com SPEEDCOM SC5800 User Manual Issue Status THIS MANUAL ADDRESS FEATURES SPECIFIC TO VERSION 2 OF THE SPEEDCOM SC5800. PLEASE IGNORE REFERENCE S TO OTHER VERSIONS. The following sections are new additions to Issue 7: • Added new address on cover page • Update on Reset Button functionality description (see page 15) • Interconnection Cable Wiring Description: corrected third columns for Pins 1 and 2 (see page 32) and added notes on bottom of page • MIB definition additions (see pages 83 through 97) • Product receive sensitivity level adjustment (see page 61) • FCC notice additions and Indoor unit firmware upgrade notice added (throughout manual) • MIB elements deprecated such as ResetALLRFPerformanceData and ResetAllG826 and other modified Groups notified by a “+” (see pages 83 through 97). FEDERAL COMMUNICATIONS COMMISSION NOTICE The equipment has been tested and found to comply with the limits for Class A digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. SPEEDCOM SC5800 User Manual WARNING- To comply with FCC RF exposure limits, the antennas for this transmitter must be fix-mounted to provide a separation distance of 2 meters (6.6 ft) or more from all persons to satisfy RF exposure requirements. This equipment must be professionally installed. Publication Number: 862-01881 Issue 7.1 September 17, 2001 Wave Wireless Networking Copyright Statement Wave Wireless Networking products are manufactured under a quality system certified to ISO 9001 specifications. All trademarks mentioned in this document are the property of their respective owners. Wave Wireless Networking and SPEEDCOM Wireless Corporation do not take responsibility for any damages incurred due to technical inaccuracies in this document. Contents are subject to change without notification. © 2001 Wave Wireless Networking. All rights reserved. Technical Support For more information, contact Wave Wireless Networking at: Wave Wireless Networking 7020 Professional Parkway East Sarasota, FL 34240 Technical Support: 941-358-9283 phone 941-355-0219 fax www.wavewireless.com SPEEDCOM SC5800 User Manual Table of Contents Page INTRODUCTION 1.1 SC5800 Description TECHNICAL DESCRIPTION 11 2.1 System Overview 11 2.2 Outdoor Unit 11 2.2.1 Frequency plans 12 2.2.2 RF Power Output Options 13 2.2.3 SC5800 Outdoor Unit 13 2.3 Indoor Unit 14 2.3.1 Payload Interface Options 14 2.3.2 Service (Wayside) Serial Data Channel 16 2.3.3 Element Manager Port 16 2.3.4 10BaseT Ethernet RJ45 Port 16 2.3.5 IU/OU Link LED 17 2.3.6 IU/OU Data Interconnect RJ45 17 2.3.7 IU/OU Power Interconnect 17 2.3.8 Auxiliary In/Out Port 17 2.3.9 DC Power Input 17 2.3.10 Fuse Holder 17 2.3.11 ON/OFF Switch 18 2.3.12 Ground Terminal 18 PLANNING 19 3.1 System Type Selection 19 3.1.1 Antenna Selection (SC5800) 19 3.2 Site Evaluation 20 3.3 Multipath Effects 20 3.4 Interference Considerations 21 3.5 Micro-cell Backhaul Applications of SC5800 Digital Radios 22 3.5.1 Setting the Transmitted Power Levels 22 3.5.2 Frequency Multiplexing 22 SPEEDCOM SC5800 User Manual 3.5.3 Antenna Isolation 22 INSTALLATION 23 4.1 Customer Furnished Tools and Equipment 24 4.2 Indoor Unit 25 4.2.1 Introduction 25 4.2.2 Installing the Indoor Unit in a Rack 25 4.2.3 Connecting a DC Power Supply 26 4.2.4 Balanced Payload Data 27 4.2.5 Connecting Auxiliary In/Out (Optional) 28 4.2.6 Connecting the Service (Wayside) Serial Channel (Optional) 29 4.2.7 Connecting the Element Manager Port 29 4.3 4.3.1 4.4 4.4.1 Outdoor Unit 30 SC5800 Outdoor Unit 30 Interconnection Cable Installation 31 INTERCONNECTIO N CABLE WIRING DESCRIPTION 32 ANTENNA ALIGNMENT AND SOFTWARE SETUP 33 5.1 Installation Equipment Required 33 5.2 Information Required 33 5.3 Antenna Alignment 33 5.3.1 Introduction 33 5.3.2 Alignment Procedure 34 5.3.3 Set Transmitted Power Level 34 5.4 Software Setup 35 5.5 Functional Test 35 5.5.1 Link Bit Error Rate Performance Test 35 5.6 SC5800 Installation Record 36 5.7 SC5800 Test Record 37 NMS SOFTWARE 39 6.1 Introduction to the Network Management System 39 6.2 General Information 39 6.2.1 6.3 6.3.1 6.4 Microwave Digital Radio 40 Main Screen 41 Link Elements Areas 42 NMS Menus 43 SPEEDCOM SC5800 User Manual 6.4.1 Main Screen Menus 43 6.4.2 Main Screen Short -cut Buttons 45 6.5 Indoor Unit Configuration 45 6.5.1 Controls 45 6.5.2 Menu Items 48 6.6 Outdoor Unit Configuration 52 6.6.1 Controls 52 6.6.2 Menu Items 52 6.6.3 OU Station Info 53 6.6.4 Outdoor Unit Status 53 6.7 RF Link Error Status Monitoring 54 6.7.1 RF Link Status 54 6.7.2 Packet Error Rate Thresholds 54 6.7.3 RF Link Error Monitor 55 MAINTENANCE INFORMATION 57 TECHNICAL DATA 59 8.1 Environmental Requirements 59 8.1.1 Outdoor Equipment 59 8.1.2 Indoor Equipment 59 8.2 8.2.1 Mechanical Information for Outdoor Equipment SC5800 Outdoor Unit 59 59 8.3 Mechanical Information for Indoor Equipment 59 8.4 Power Supply Requirements 59 8.5 Electrical Performance 60 8.5.1 General Characteristics 60 8.5.2 Transceiver Characteristics 60 8.5.3 RF Interface 61 8.5.4 Payload Data Interfaces 61 8.5.5 Auxiliary Input Interface (CONTACT CLOSURE) 62 8.5.6 Auxiliary Output Interface 62 8.5.7 Wayside channel interface 62 8.5.8 Element Manager Port Interface 62 8.5.9 Indoor/Outdoor Unit Interface 62 8.6 Ordering Information 64 SPEEDCOM SC5800 User Manual APPENDIX A: ELEMENT MANAGER PORT POINT-TO-POINT SERIAL COMMUNICATIONS SETUP 67 9.1 Adding a Modem: Windows NT 68 9.2 Adding Dial-up Networking: Windows NT 72 9.2.1 To add dial-up networking 72 9.3 Adding a Modem: Windows 95/98 77 9.4 Adding Dial-up Networking: Windows 95/98 79 10 APPENDIX B: MANAGEMENT OF THE SC5800 81 10.1 SNMP and the SC5800 81 10.2 The MIB Elements – OID (Object ID) DESCRIPTIONS 83 10.3 The MIB elements – TRAP DESCRIPTIONS 97 11 APPENDIX C: SETUP OF A PC (WIN 95, 98, NT) TO ALLOW PINGING OF A ‘REMOTE’-CONFIGURED INDOOR UNIT 101 11.1 IP CONFIGURATION OF THE SC5800 – ROUTING CONFIGURATION 101 11.2 IP CONFIGURATION OF THE SC5800 – BRIDGING AND ROUTING CONFIGURATION 103 12 APPENDIX D: SC5800 HARDWARE VERSION 2.X DIFFERENCES, COMPATIBILITY SUMMARY 105 13 APPENDIX E: FIXED ANTENNAS 106 SPEEDCOM SC5800 User Manual SPEEDCOM SC5800 User Manual List of Abbreviations BIT Built-in-Test AIS Alarm Indication Signal PER Packet (or Block) Error Rate DC Direct Current DCE Data Communications Equipment DRL Digital Radio Link DRS Digital Radio Station DTE Data Terminal Equipment IU Indoor Unit ISM Industrial, Scientific and Medical LED Light Emitting Diode LOS Loss of signal Mbps Megabits per second N.C Normally-closed N.O Normally-open NMS Network Management System OU Outdoor Unit PC Personal Computer RF Radio Frequency RSSI Received Signal Strength Indication SNMP Simple Network Management Protocol SPEEDCOM SC5800 User Manual 1 INTRODUCTION 1.1 SC5800 Description The SC5800 is a 5.8 GHz digital radio system that provides short to medium range, point-to-point digital communication with high data security at rates of E1, 2E1 or 4E1. Alternatively, the radio can be software configured to convey T1, 2T1 or 4T1. The radio can also be configured to bridge or route IP via a 10BaseT Ethernet port. The data rates scale depending on the number of enabled E1/T1 tributaries and whether the data is being bridged or routed. The product makes use of spread spectrum technology and may be operated license-free in the 5.8 GHz ISM band. It is ideal for applications such as: • Telecommunications companies, cellular operators and private carriers. • Cellular/PCS base station interconnects. • Internet distribution. • Video surveillance data distribution. • Rural communications. The SC5800 consists of two main parts: • An Outdoor Unit operating in the 5.8 GHz ISM frequency band. • An Indoor Unit, available with a Telecommunications (1, 2 or 4E1 or 1, 2 or 4T1) interface and a Data interface (10BaseT Ethernet). Interconnection between the Outdoor Unit and Indoor Unit is achieved using a lowcost UV-protected STP (Screened Twisted Pair: 4 pairs) data cable and a UVprotected 2-core power cable. The SC5800 series product uses a split Indoor Unit and Outdoor Unit configuration for lowest loss between the antenna and the transceiver, thereby ensuring optimal long-range performance. SC5800 Outdoor Unit uses a Type-N RF (female) output connector for connection to any 5.8 GHz antenna for applications where long range is required. SPEEDCOM SC5800 User Manual Table 1 lists the SC5800 model variants. Table 1. SC5800 model variants Model Number Interfaces Antenna Coupling Antenna Type SC5801 E1/T1 N-type Female Customer supplied N-type Female Customer supplied N-type Female Customer supplied 10BaseT Ethernet SC5802 2 x E1 / 2 x T1 10BaseT Ethernet SC5804 4 x E1 / 4 x T1 10BaseT Ethernet For information about ordering supplies, see Section 8.6, Ordering Information, page 64. The Network Management System provides control and management of the product. SNMP support via an SNMP agent in the Indoor Unit ensures open network management compatibility. Comprehensive data and RF loop-back functions ensure that the system is easy to install and maintain. 10 SPEEDCOM SC5800 User Manual 2 TECHNICAL DESCRIPTION 2.1 System Overview A SC5800 digital radio link (DRL) consists of a pair of SC5800 radio stations. SC5800 ODU SC5800ODU SC5800 IDU SC5800 IDU User Data User Data The SC5800 radio station consists of two main parts: • An Outdoor Unit operating in the 5.8 GHz ISM frequency band. The Outdoor Unit provides the radio transceiver functionality by accepting radio link data from the Indoor Unit and converting it to the 5.8 GHz ISM frequency band using spread spectrum modulation. The received signal is de-spread and transmitted to the Indoor Unit in a digital format. • An Indoor unit, available with 1, 2 or 4 E1 and 1, 2 or 4 T1 data interfaces (choice of E1 or T1 is software selectable). The Indoor Unit combines nE1 or nT1 data with Wayside Service Channel serial data and link IP data to be transmitted across the radio link. The Indoor Unit also provides power to the Outdoor Unit. Interconnection between Outdoor Unit and Indoor Unit is achieved using low cost data and power cables. 2.2 Outdoor Unit The SC5800 Outdoor Unit makes use of Spread Spectrum modulation technology for license-free operation in the 5.8 GHz ISM band. For SC5800 operation, the 5.8 GHz ISM band is divided into upper and lower frequency sub-bands. An SC5800 ‘High Band’ Outdoor Unit transmits in the higher frequency sub-band and receives in the lower frequency sub-band, while a ‘Low Band’ Outdoor Unit transmits in the lower sub-band and receives in the higher subband. An SC5800 radio link will use a ‘Low Band’ Outdoor Unit on one end of the link to communicate with a ‘High Band’ Outdoor Unit on the other end. The SC5800 Outdoor Unit uses a Type-N RF output connector for connection to any 5.8 GHz antenna for applications where long range is required. 11 SPEEDCOM SC5800 User Manual 2.2.1 Frequency plans The SC5800 Outdoor Units operate in the 5.725 GHz to 5.850 GHz ISM frequency band. The SC5800 has predefined frequency channel plans (termed A, B, C and D). 2.2.1.1 Frequency Channel Plan A, B and C Transmit-to-receive channel spacing for frequency channel plans A, B and C is 69 MHz. The channel spacing is based on the bandwidth occupied by the spread spectrum signal (approximately 17 MHz) and is used to optimize link performance. In the case of plan A, plan B and C, note that both Outdoor Units of a link must be set up to the same frequency channel plan (i.e., A, B or C). LOW BAND TRANSMIT AL 5735 HIGH BAND TRANSMIT BL CL CH BH AH 5753 5771 5804 5822 5840 Frequency (MHz) Figure 1. Frequency channel plans A, B and C 12 SPEEDCOM SC5800 User Manual Frequency Channel Plan D Frequency plan D allows independent control of transmit and receive frequencies. This enables a very flexible frequency plan and can be used to overcome interference in the 5.8 GHz ISM band. The frequencies that can be used in the lower or upper sub-bands can be selected in 1 MHz increments. Performance degradation can be expected when operating using channel plan D mode and the chosen frequencies are close to the sub-band edges, such as a choice of one of the high frequencies in the lower sub-band and one of the lower frequencies in the upper sub-band. The allocation of Channel plan D frequencies is shown in Table 2. Table 2. Channel plan D channel frequencies Sub-band Center Frequency (M Hz) 5735-5771 5804-5840 2.2.2 RF Power Output Options It is possible to adjust the output power on the OU using the supplied NMS software or a SNMP Management application. 2.2.3 SC5800 Outdoor Unit The SC5800 Outdoor Unit transmits and receives RF through a diplexer interfaced via an RF cable to an external antenna. The unit has a type-N connector for connection to the RF cable used between the OU and the antenna. The SC5800 Outdoor Unit houses the following main parts: • Transmit/Receive Modules • Baseband Modulator/Demodulator Circuitry • Microcontroller/Framing & Buffering Circuitry • Power Amplifier • Diplexer 13 SPEEDCOM SC5800 User Manual 2.3 Indoor Unit The Indoor Unit is designed for mounting in a 19” rack, occupying a 1U slot, or can be tabletop standing. The Indoor Unit accepts user nE1/nT1 and combines it with Wayside Service Serial Data and IP data to be transmitted across the radio link. The Indoor Unit is fitted with a DC power supply. An AC Bench Power supply can be purchased separately. 2.3.1 Payload Interface Options The Indoor Unit can be configured for nE1 or nT1 operation. • 1, 2 or 4 x E1 (2.048 Mbps) • 1, 2 or 4 x E1 (1.544 Mbps) For E1 connectivity, bipolar AMI or HDB3 line coding is software selectable. For T1 connectivity, bipolar AMI or B8ZS line coding is software selectable. nE1/nT1 Connector Element Manager Connector Reset/Configuration Button System LED Payload LED 10BaseT RJ45 Socket RF Link LED Ethernet Link LED Figure 2. Indoor Unit Front Panel Wayside Service Serial Channel The Indoor Unit LED functionality is described as follows: SYSTEM Green OK, Orange (OU/IU Comms Error), Red (OU/IU Comms Down) PAYLOAD Green OK, Orange (AIS Detected), Red (LOS Detected) RF LINK Green OK, Orange (FEC Correcting Errors), Red (FEC unable to correct errors) 14 SPEEDCOM SC5800 User Manual Note: In ALL cases flashing red and orange LEDs imply historic alarm conditions (The alarm can be cleared using the front panel button ‘position 1’: see next section). Reset/Configuration Button The Front Panel Button has the following functionality used to set up a radio (as determined by different LEDs lighting up. ‘Position 1’ being RF Link LED (Green), 2 being Payload LED (Green), 3 being System LED (Green), 4 being RF Link LED (Orange), 5 being Payload LED (Orange) and 6 being System LED (Orange) etc. 1. Clear Front Panel LEDs (and associated alarms in IU) 2. Clear Event Log in the Indoor Unit 3. Reset the Indoor Unit (don’t reset the non-volatile memory’s store of the IU’s configuration parameters) 4. Routed Configuration: Reset the IU configuration parameters that are stored in non-volatile memory (BATTERY-BACKED STATIC RAM) and configure as a ‘Far Side IU’: (i.e., for a ROUTED IP configuration), set the Ethernet IP address as 10.11.1.2, Element Manager IP address to 10.12.1.2 5. Routed Configuration: Reset the IU configuration parameters that are stored in non-volatile memory and configure as a ‘Near Side IU’: i.e. for a ROUTED IP configuration set the Ethernet IP address as 10.2.1.2, Element Manager IP address to 10.13.1.2 6. Routed Configuration: If you are not sure how the IU is configured (NEAR or FAR side IU), reset it AS IS i.e. reset the ‘Near Side IU’ or ‘Far Side IU’ configuration parameters depending on how the IU is currently configured. 7. Bridged Configuration: Reset the IU configuration parameters that are stored in non-volatile memory (BATTERY-BACKED STATIC RAM) and configure as a ‘Far Side IU’. For a BRIDGED IP configuration, see Appendix C of this document for a description of the default IP addresses. 8. Bridged Configuration: Reset the IU configuration parameters that are stored in non-volatile memory and configure as a ‘Near Side IU’. For a BRIDGED IP configuration, see Appendix C of this document for a description of the default IP addresses. 9. 9, 10, 11 RESERVED 12. Set up Indoor Unit with E1 tributaries. 13. Set up Indoor Unit with T1 tributaries. 14. Deactivate buttons 4 onwards. 15. NB: All buttons can be REACTIVATED (i.e. undoing a 14 'reset') by doing a power-on reset while holding the front-panel Reset Button in. WARNING! POSITIONS 4, 5, 6, 7 and 8 RESET THE INDOOR UNIT TO FACTORY DEFAULTS – THESE RESETS ARE TYPICALLY ONLY USED ONCE (THESE CHOICES RESET CERTAIN ADJUSTABLE PARAMETERS IN NON-VOLATILE MEMORY IN THE INDOOR UNITS). IF CHANGES ARE MADE TO THE CONFIGURATION PARAMETERS AND THE USER DOES NOT WANT THESE TO CHANGE WHEN A UNIT IS RESET, THE INDOOR UNIT CAN BE POWER-CYCLED OR POSITION ‘3’ MUST BE USED E.G. THIS TECHNIQUE IS USED IF THE IP ADDRESSES ASSOCIATED WITH 15 SPEEDCOM SC5800 User Manual THE NETWORK INTERFACES ARE ADJUSTED – THE PROCESSOR NEEDS TO BE RESET TO ALLOW THE CHANGE/S TO BE IMPLEMENTED. IF YOU OVER-RUN THE SELECTION YOU REQUIRE, CONTINUE UNTIL THE LEDs GO BLANK – THEN, START AGAIN (OPTION AVAILABLE WITH RELEASE 2 OF IU FIRMWARE). 2.3.2 Service (Wayside) Serial Data Channel This port supports asynchronous full duplex, serial data transfer at a speed of 115200 bps. The interface type is RS -232 configured as DCE (Data Communications Equipment). Handshaking can be None, Hardware. 2.3.3 Element Manager Port This port is used for communication with the NMS software or with an SNMP manager to control the SC5800 system. The port must be connected to a serial port (configured for a speed of 115200 bps) on a personal computer to use the NMS software. The interface type is RS -232 configured as DTE (Data Terminal Equipment). Hardware handshaking is used. 2.3.4 10BaseT Ethernet RJ45 Port This port is used for communication with the NMS software or with an SNMP manager to control the SC5800 system. The interface type is DTE (Data Terminal Equipment). IU/OU Power Interconnect DC In IU/OU Data Interconnect RJ45 IU/OU Link LED Auxiliary IO Fuse Holder ON/OFF Switch Ground Terminal Figure 3. Indoor Unit Rear Panel 16 SPEEDCOM SC5800 User Manual 2.3.5 IU/OU Link LED This LED indicates if there is a suitable electrical connection between the Indoor and Outdoor Units1. 2.3.6 IU/OU Data Interconnect RJ45 This receptacle accepts an RJ45 plug that connects to UV-protected STP (Screened twisted pair) cable used between the IU and the OU. 2.3.7 IU/OU Power Interconnect This connector (socket) is used for power interconnection between the IU and the OU. The connection is made using UV-protected 2-core cable. The cable is connected to a GREEN connector, (i.e., a plug). The polarity sense (labeled) must be maintained between the IU and the OU. 2.3.8 Auxiliary In/Out Port The auxiliary in/out port is used for remote monitoring and control. The following are provided: • Two inputs (for sensing contact closure or opening) are provided to sense site alarm inputs. The states of these alarm inputs can be monitored with NMS, as well as from an SNMP Management Station. • Two relay contact outputs, normally-open and normally-closed contacts, are provided as alarm / auxiliary outputs. Output states are software customized and controlled. The outputs are used to indicate alarm or other states selected by the operator via the NMS or a SNMP Management Station. 2.3.9 DC Power Input This connector (socket) is used for power input to the IU. The connection is made using 2-core cable. The cable is connected to a gray connector, a plug. The polarity-sense (labeled) must be observed and implemented. 2.3.10 Fuse Holder This holder is used to hold a fuse (5A). Note that only the Ethernet Physical interface is checked on V1 hardware with this LED, not the RS232/485 interface. The integrity of the RS232/485 interface is checked using the front panel “System LED”. 17 SPEEDCOM SC5800 User Manual 2.3.11 ON/OFF Switch This switch is used to control power input to the Indoor Unit (and indirectly the Outdoor Unit). 2.3.12 Ground Terminal This is used to accept connection to an earth strap, terminated with a crimped earth lug. For details on wire/earth lug requirements, see Section 4.1, Custom Furnished Tools & Equipment, page 24. 18 SPEEDCOM SC5800 User Manual 3 PLANNING This chapter is aimed at management and planning staff to enable them to assess the requirements for installing an SC5800 digital radio link. 3.1 System Type Selection The SC5800 system uses an Outdoor Unit with a type-N RF output for connec tion to a range of antennas. Antenna polarization can used to co-locate multiple SC5800 systems. Antenna polarization can be used to overcome interference. 3.1.1 Antenna Selection (SC5800) The antenna type must be selected before the SC5800 system is to be installed. The chosen antenna must enable the system to operate with sufficient link fade margin without excessive cost and allow the user’s ‘link availability requirements’ to be met. The main consideration when selecting an antenna is antenna gain measured in dBi. A path loss analysis is highly recommended to determine the antenna gain needed for adequate fade margin. The table below shows antenna selection guidelines for some configurations. The distances are calculated for a 20 dB link fade margin. Ta ble 3 SC25800 Antenna Selection Antenna Type Gain (dBi) Distance (Km) Power level (dBm) 0.15 m Flat panel 18 24 0.3 m Flat panel 24 30 24 0.6 m Flat panel 28 80 24 19 SPEEDCOM SC5800 User Manual 3.2 Site Evaluation When planning a site for a digital radio link, it is of the utmost importance that you take the operational environment of the proposed site into account. The combined effect of atmospheric environmental factors such as rain and lightning, atmospheric attenuation, signal path obstruction, propagation fading, air temperature gradients, ice build-up, wind and solar radiation can contribute towards reducing the level of performance of the system. In the higher frequency bands, rainfall is the main attenuation mechanism that limits error performance. Ice and snow will have a similar effect. Severely cold and excessively warm climatic conditions outside the scope of the operating temperature range can affect the function of the system, especially the outdoor equipment (see Section 8.1, Environmental Characteristics, page 59 of this manual). Also, if masts are not sufficiently rigid, very strong winds can affect the antenna beam alignment and outdoor equipment reliability due to wind force build-up and/or vibration of the mast-mounted equipment. 3.3 Multipath Effects The SC5800 digital radio operates at frequencies close to 5.8 GHz and can be influenced by the effects of multipath propagation. Understanding these effects will help when installing an SC5800 digital radio link and maximize the reliability of the link. Multipath fading occurs when the receiving antenna receives not only the direct signal from the transmitting antenna but also a signal from the transmitting antenna that has reflected off the ground or nearby obstacles. The reflected signal takes a longer path to reach the receiver and acts as interference since it is not in-phase with the direct path signal. The amplitude of the interference can be almost equal to that of the direct path signal, thus degrading the performance of the link . Multipath propagation is dependent on transmit frequency and the specific geometry of the link such as antenna heights, distance between the antennas and the local terrain. To counteract multipath propagation, the installer can change the frequency at which the link operates or adjust the height of one or both of the antennas. Direct RF Path SC5800 OU SC5800 OU Reflection Path SC5800 SC5800 IU User Data User Data Figure 4. Multipath Effects. 20 SPEEDCOM SC5800 User Manual 3.4 Interference Considerations The ISM frequency bands are used by devices that can cause interfe rence to the SC5800 radio system. Interference can be avoided by careful planning of the system installation. The available methods for providing isolation from interfering radiators are the following: • Frequency diversity • Antenna polarization It is recom mended to scan the proposed installation areas (using a spectrum analyzer) to establish the presence of interference. The frequency spectrum should be scanned over a sufficient time period to ensure that periodic transmissions are recorded. Interferers will cause problems if their amplitudes are not more than 20 dB below the intended receive power level. A link path loss calculation should be performed to determine the expected receive power level. The procedure for selecting the optimum antenna polarization and system frequency plan is the following: • Perform a spectral analysis at each site in the link direction using a high gain antenna. • Repeat the spectral analysis for vertical and horizontal polarization. • Select the polarization with the lowest interfering levels as the system antenna polarization. • Consult the SC5800 frequency channel plan as shown in Section 2.2.1, Frequency Plans, page 12. Then, select the frequency plan that would operate in an interference-free band. Give preference to channel plans A, B and C as these are optimized for best receiver sensitivity. • Install the ‘High Band’ and ‘Low Band’ Outdoor Units at the sites where they would experience the lowest interference in their respective receive bands. 21 SPEEDCOM SC5800 User Manual 3.5 Micro-cell Backhaul Applications of SC5800 Digital Radios In applications where more than one independent and separate links, need to radiate from a central site, a number of parameters can be taken advantage of, to provide isolation and minimize interference between these links: • Frequency multiplexing • Antenna polarization • Choice of High Antenna Gain It is important to note that these methods only provide isolation between two radio systems, and that power levels in the separate systems should be balanced to ensure correc t operation. 3.5.1 Setting the Transmitted Power Levels To minimize interference, received power levels should be balanced between separate radio links. This means that transmit power levels should be set to provide similar levels of received power, as indicated by the RSSI values of the adjacent receivers at the central site. 3.5.2 Frequency Multiplexing The SC5800 offers four frequency channel plans. A radio link requires two channels (one for transmit and one to receive) to provide full-duplex operation. Each radio has a high and a low subband, one that it uses for transmission and another for reception. Terminology definition: the ‘High-band Outdoor Unit’ of a system transmits on the higher of the two sub-bands. The ‘Lowband Outdoor Unit’ of a system transmits on the lower of the two sub-bands. A system (link) always has one High Band and one Low Band Outdoor Unit. It is important to note that unwanted transmitted signals in adjacent frequency bands can affect other receivers operating in an adjacent band if insufficient antenna isolation is provided. A solution is to group high-band or lowband Outdoor Units at the central site, rather than group high and low-band Outdoor Units together. 3.5.3 Antenna Isolation Separate links at a central site will have sufficient isolation when radio systems operate outside the radiation beamwidth or side lobes of the system antenna. The achievable isolation can be established by examining the measured radiation patterns of the system antennas. Directional isolation can be used if the antenna radiation is 15 dB or lower relative to the adjacent main beam. Antennas with high directionality will allow reduced angular separation of adjacent systems. Antenna cross-polarization isolation can be used for adjacent radio links, radiating in the same direction. Typical isolation of 30 dB can be achieved using high quality antennas. 22 SPEEDCOM SC5800 User Manual 4 INSTALLATION This section describes a recommended installation procedure for the SC5800. Recommended installation procedure: 1. Install the Indoor Unit. 2. Prepare and connect the cables to the Indoor Unit. 3. Install the Outdoor Unit and antenna. 4. Install the Indoor-to-Outdoor Unit interconnection cables (the power and data cables). 5. Turn the Indoor Unit power on. 6. Perform the initial software setup using the supplied NMS application 7. Repeat items 1-5 for the remote site. 8. Align the antennas (use the RSSI voltage on the OU or the RSSI value from the MIB or the NMS Graphic User Interface to assist with the setup). 9. Perform a functional test and commission the link. 10. Connect to user data. 11. Start the system. Installation of the SC5800 elements is described in the following sections: • Installing the Indoor Unit. • Installing the Outdoor Unit and Antenna. • Installing the interconnection cables. 23 SPEEDCOM SC5800 User Manual 4.1 Customer Furnished Tools and Equipment The following table lists tools and equipment required to install the SC5800 system. General, IU-to-OU Interconnect • Cable cutting and stripping tools. • Earth lug crimp tools. • 3 mm flat screwdriver - IU to OU power cable. • RJ45 crimp tool - IU to OU data cable. • Earth cable or strap rated at 45A with 5 mm earth lug earthing the Indoor and Outdoor Units. • Cable ties, used to secure the cables to the mast at regular intervals. IU • Pozi #2 screwdriver - IU mounting in a 19" rack and the earth lug. • 2.5mm Allen key - To change the position of the IU mounting brackets. • DC power supply cable: minimum 2.5 mm square conductor, rated for 10 A. For connection between the power supply and the Indoor Unit DC connector on the rear panel. • IU earth lug: 10-4 (10 square mm for wire and hole big enough for M4 thread) OU • 13 mm spanner (or Wrench) – used for attachment of OU to mounting bracket. • 13 mm spanner - used for attachment of OU mounting bracket to pole. • 2.5 mm Allen key - used to tighten OU connection box cover fasteners. • OU earth lug: 10-8 (10 square mm for wire and hole big enough for M8 thread) For details on the data and RF cables, which are also customer furnished equipment, see Section 7, Maintenance Information, page 57. 24 SPEEDCOM SC5800 User Manual 4.2 Indoor Unit 4.2.1 Introduction This section describes the recommended installation procedure for the Indoor Unit. The Indoor Unit is designed for mounting in the DIN 41494 (19") racking standard and occupies a 1U high slot. Desktop mounting is also possible. The Indoor Unit’s payload (nE1, nT1 and 10BaseT Ethernet) and Service Channel (‘Wayside serial’) data interfaces and Element Management interface are located on the front panel. Input Power, Auxiliary alarm and ‘IU/OU Interconnect’ interfaces are located on the rear panel, suitable for rack installations. IU/OU Power Interconnect DC In IU/OU Data Interconnect RJ45 Auxiliary IO Fuse Holder IU/OU Link LED ON/OFF Switch Ground Terminal The recommended installation procedure for the Indoor Unit is the following: • Install the Indoor Unit in the rack. • Earth the Indoor Unit. • Connect the DC power supply. • Connect Payload data ports (front panel). • Connect Auxiliary In/Out port (optional). • Connect Service Channel (Wayside) serial port (optional). • Connect the Element Manager port using the supplied cable (front panel). 4.2.2 Installing the Indoor Unit in a Rack 1. Slide the Indoor Unit into the 19" rack and secure to the rack using four M6 x 18 mm screws. 2. Earth the Indoor Unit by connecting the earth cable or strap between the station earth and the earth stud on the Indoor Unit rear panel. 25 SPEEDCOM SC5800 User Manual 4.2.3 Connecting a DC Power Supply WARNING – See Section 8.4, Power Supply Equipments, page 59 for specification of the power supply. 1. Observing the polarity of the supply, wire up the supplied power connector cable plug and connect it to the DC supply (21 to 56 V) through a minimum 5 A circuit breaker. 2. Check the supply voltage using a multimeter. 3. Secure the connector screws to the unit. DC Power Connector Pinouts Indoor unit connector Gray Pin No Signal DC POWER DC POWER RETURN 2-pin Wieland Type 8213 + DC - 26 SPEEDCOM SC5800 User Manual 4.2.4 Balanced Payload Data 1. Assemble the (nE1) / (nT1) payload data input and output cable. See the table below for Indoor Unit connector pin assignments. 2. Connect the payload data cable to the DB25 connector on the front panel of the Indoor Unit. D-Type Payload Data Connector Pin Name Tributary Direction Pin # GND Earth N/A RTIP1 RX + RRING1 RX - GND Earth TTIP1 TX - TRING1 TX + GND Earth N/A GND Earth N/A RRING0 RX + 10 RTIP0 RX - 11 GND Earth 12 TRING0 TX - 13 TTIP0 TX + 14 TRING2 TX - 15 TTIP2 TX + 16 GND Earth 17 RRING2 RX+ 18 RTIP2 RX- 19 GND Earth 20 TTIP3 TX- 21 TRING3 TX+ 22 GND Earth 23 RTIP3 RX+ 24 RRING3 RX- 25 GND Earth N/A N/A N/A N/A N/A N/A 27 SPEEDCOM SC5800 User Manual 4.2.5 Connecting Auxiliary In/Out (Optional) The auxiliary in/out port is used to: • Monitor switch-closure events using two isolated inputs. • Control line connections using normally-open and normally-closed relay outputs. Connect the port: 1. Assemble an auxiliary in/out cable using a High-density 15 way D-type male connector according to connector pin assignments shown in Table 4. 2. Connect to the cable Indoor Unit auxiliary in/out connector. 3. Secure the connector using locking screws. Table 4. Auxiliary In/Out Connector Pin Outs Indoor unit connector Pin No Signal 15-pin High density D-type female OUTPUT 1 COMMON OUTPUT 1 NORMALLY-OPEN OUTPUT 1 NORMALLY-OPEN OUTPUT 1 NORMALLY-CLOSED OUTPUT 1 NORMALLY-CLOSED OUTPUT 1 COMMON OUTPUT 2 COMMON OUTPUT 2 COMMON OUTPUT 2 NORMALLY-OPEN 10 OUTPUT 2 NORMALLY-OPEN 11 OUTPUT 2 NORMALLY-CLOSED 12 INPUT 1 13 INPUT 1 RETURN 14 INPUT 2 15 INPUT 2 RETURN 10 15 11 28 SPEEDCOM SC5800 User Manual 4.2.6 Connecting the Service (Wayside) Serial Channel (Optional) This ‘clear’ serial channel can transport up to 115,200 bps across the radio link. This channel does not interfere with the payload data channels. The port is configured as DCE. 1. Connect the serial data interface cable to the Service channel connector on the Indoor Unit rear panel. The supplied serial data cable can be used to connect to this port after the software setup is completed. 2. See the table below for Indoor Unit connector pin assignments when a custom cable needs to be assembled. 3. Secure the connector using locking screws. Service Channel Connector Pinouts Indoor Unit connector Pin No Signal 9-pin D-type Female Connector TD RD DTR GROUND DSR RTS CTS 4.2.7 Connecting the Element Manager Port The Element Manager port is used to connect the Indoor Unit to a PC/Laptop serial port. This enables the Indoor Unit to be configured using the supplied NMS software or controlled via a PPP-dialup connection. The port can be connected to using the supplied serial data cable. The port is configured as DTE. 29 SPEEDCOM SC5800 User Manual 4.3 Outdoor Unit Before installing the SC5800 Outdoor Unit, ensure that a suitable mast is used for the antenna and that the Outdoor Unit installation is firmly in position. The pole diameter must be between 50 and 102 mm. CAUTION – ENSURE THAT THE POLE IS GROUNDED FOR LIGHTNING PROTECTION. 4.3.1 SC5800 Outdoor Unit Follow these steps to install the SC5800 Outdoor Unit: 1. Install the system antenna. 2. Adjust the mounting bracket to be slightly bigger than the pole diameter. 3. Secure the mounting bracket to the pole. 4. Secure the Outdoor Unit to the bracket using the screws on each bracket. 5. Connect the Outdoor Unit to the pole electrically by connecting the earth cable or strap between the pole earth and the Outdoor Unit earth point. 6. Connect the type-N RF output connector to the system antenna through an in-line lightning protection unit in areas with lightning activity. 7. Cover the connectors using an ultra violet protective, self-vulcanizing tape. 4.3.1.1 RF Connection 1. 2. 3. 4. 5. The RF port is an N-type female connector. The N-Type connector is used to connect to the antenna, typically using coaxial transmission line. 1/2" or 5/8” coaxial cables are recommended. Coaxial cable that is 7/8” or larger can exhibit moding at 5.8 GHz and is not recommended for 5.8 GHz radios. Do not use right angle N-type connectors with the 5.8 GHz radios: they may present high loss at 5.8 GHz. Do not use low quality cables. Some cable types, such as RG-8, may have too high a loss at 5.8 GHz. 30 SPEEDCOM SC5800 User Manual 4.4 Interconnection Cable Installation Follow these steps to install the Indoor Unit to Outdoor Unit interconnection cables. CAUTION DO NOT OVER TIGHTEN THE CABLE STRAPS ON THE CABLES AND DO NOT FASTEN THE STRAP LOCKING MECHANISM OF THE CABLE STRAP ONTO THE CABLES. 1. On the OU side, connect an RJ45 plug to the data cable. Place the RJ45 plug into the RJ45 socket in the Outdoor Unit connection box. 2. On the OU side, connect the DC power leads within the Outdoor Unit Connection Box. Use the +Ve and Return connections. RJ45 Socket Return +Ve "Chassis" 3. Close the Outdoor Unit Connection Box Cover using a 2.5mm Allen key. Make sure the rubber gaskets seal correctly over the power and data cables. 4. Using cable ties, secure the cable to the pole at regular intervals. 5. On the IU side, connect an RJ45 plug to the data cable. Place the RJ45 plug into the RJ45 socket in the rear of the Indoor Unit. 6. On the IU side, connect the DC power leads to the supplied GREEN Phoenix plug. Insert this plug into the green socket on the rear-panel of the IU. 7. The user can see that there is a suitable IU/OU data interconnection if the ‘IU/OU Link’ LED on the rear-panel of the IU is lit up green. CAUTION UNDO THE SCREWS OF THE “CONNECTION BOX” IN A UNIFORM MANNER. THIS ENSURES THAT THE “CONNECTION BOX” GASKET MATERIAL RELEASES STRESS UNIFORMLY AND DOES NOT LEAD TO THE SECURING SCREWS BEING BENT DUE TO THE PRESSURE PLACED ON THE CONNECTION BOX LID. 31 SPEEDCOM SC5800 User Manual 4.4.1 INTERCONNECTION CABLE WIRING DESCRIPTION TOP VIEW (LOCKING TAB UNDERNEATH) RJ-45 PLUG Pin DTE (on INDOOR UNIT) DCE (on OUTDOOR UNIT) TxD+ RxD-+ TxD- RxD-+ RxD+ TxD+ 4† TxC+ RxC+ 5† TxC- RxC- RxD- TxD- 7† RxC+ TxC+ 8† RxC- TxC- NOTES • • • † Version 2 releases of the hardware (indoor and outdoor units) cannot be used interchangeably. For version 2 IU & OU hardware, use of TxC+, TxC-, RxC+, RxC- falls away and only two (2) twisted pairs are required. The important point is that the interconnect cable is wired as a standard 1-to-1 Ethernet patch cable. Pairs 4/5 and 7/8 are not required or used on Version 2 products. 32 SPEEDCOM SC5800 User Manual 5 ANTENNA ALIGNMENT AND SOFTWARE SETUP This chapter describes the procedure for software setup and antenna alignment. The setup is done with a PC running the supplied NMS software. For more information, see Section 6, NMS Software, page 39. 5.1 Installation Equipment Required The following tools and instruments are required for software setup and aligning the antenna: • RSSI test cable • Voltmeter • Spanner, also called a Wrench, (see appropriate details in installation chapter depending on the antenna being used) • PC with NMS software and supplied serial data cable. • Binoculars (optional) used for locating the far end site. This will assist in the antenna alignment operation. • GPS or Standard Compass (optional) used for locating the far end site. This will assist in the antenna alignment operation. • Bit Error Rate Tester and connecting leads. 5.2 Information Required You should know: • Proposed frequency channel plan for each station. • Expected receive level based on the chosen system configuration and a pathloss analysis. 5.3 Antenna Alignment 5.3.1 Introduction The SC5800 should be installed on both sites before alignment starts. Perform the following steps at both stations: 1. Switch the Indoor Unit power ON. 2. Install and run the SC5800 NMS Software application. 3. Configure the radio channel plan as required. 4. Set the transmitted power to maximum. 5. Perform a RF loopback test at eac h site before starting the alignment procedure. 33 SPEEDCOM SC5800 User Manual 5.3.2 Alignment Procedure 1. Locate the far site and point the antenna to the antenna at the far site, as accurately as possible using binoculars or a compass. 2. Connect the multimeter to the RSSI connector on the Outdoor Unit using the supplied RSSI test cable and set the multimeter to measure volts. 3. Check the RSSI level and refer to the figure below for received power level. 4. Align the antenna until the maximum RSSI is attained. 5. Secure the antenna. 6. Measure the RSSI leve l and record the value (see Section 5.7, SC5800Test Record, page 37). 7. Compare with the value with that calculated for the link (i.e., using the pathloss calculation done when planning the link). Figure 5. Typical Version 2 OU RSSI Voltage as a function of RF input power level -80dBm Average 0.436 ± 0.029 V: MIB RSSI 95 ± 1 dBm (see comment below) -30 dBm Average 1.333 ± 0.047 V: MIB RSSI 54 ± 2 dBm (see comment below) The MIB lists a dBm value representative of the received signal level. The value detected is representative of the level that would be measured should a CW signal be input at the Outdoor Unit's Diplexer RF Port - a Spread Spectrum signal will appear to be 20 dB lower. The NMS makes an adjustment for this by using a 20 dB offset (addition to the Indoor Unit MIB-indicated value). The front panel RF Link LED, the Received Signal Strength Indicators (RSSI : on NMS, via SNMP or as an Electrical signal on the Outdoor Unit), Carrier-detect (NMS, SNMP) and Frame Lock (NMS, SNMP) indicators are available to assist with link installation and alignment. The front panel RF Link LED, the Received Signal Strength Indicators (RSSI: on NMS, via SNMP or as an Electrical signal on the Outdoor Unit), Carrier-detect (NMS, SNMP) and Frame Lock (NMS, SNMP) indicators are available to assist with link installation and alignment. 5.3.3 Set Transmitted Power Level It is good practice to match received power levels by adjusting transmitted powers if co-located systems are being installed. This is important to avoid interference between co-located systems. An attenuator can be fitted between the Outdoor Unit and the antenna if the power level cannot be sufficiently reduced. The dBm output at the OU N-type connector (socket) levels are set via the NMS or using a SNMP Management application. 34 SPEEDCOM SC5800 User Manual 5.4 Software Setup Refer to Section 6, NMS Software, page 39, for setting up the following: • Payload interface. • Service Channel (Wayside) serial port. • Auxiliary in/out port. • General link parameters. 5.5 Functional Test After completing the physical installation of the Indoor Units, antennas, Outdoor Units and the interconnection cables, you need to commission the system. This procedure describes how to set up the minimum requirements for successful SC5800 system operation. 5.5.1 Link Bit Error Rate Performance Test To start: when the link is setup correctly, the RF Link LEDs on both IUs on both sides of the RF link should be GREEN. When the link has been setup and is running error-free: 1. Clear the Indoor Unit Log using Reset Button Position ‘2’ 2. Clear the Indoor Unit Errors using Reset Button Position ‘1’ Perform a link bit error rate performance test as follows: • Connect a bit error rate tester to the payload interface of the link. • Run data over the link for a period of 24 hours. • Record the BER. • Record the LED statuses. Check the Indoor Unit Packet Error Results via the NMS or via SNMP access to the Indoor Unit MIB – for the NMS, right-click on the antennas in the NMS for either side of the link and select the “Diagnostic/Error Monitor” option. Record the results by saving the data to a file. For SNMP access, use a MIB Browser and check the mdrmteRFLinkPerf and mdrmteG826 Performance groups. Record all results on a test record. See Section 5.7, SC5800 Test Record, page 37 for an example. 35 SPEEDCOM SC5800 User Manual 5.6 SC5800 Installation Record Parameter Unit Site A Site B Site Name Antenna Type RF cable length Meters Lightening protection unit Yes/No Interconnecting cable length Meters Outdoor Unit serial number Indoor Unit serial number Outdoor Unit earthed Yes/No Indoor Unit earthed Yes/No Power Supply Volts DC/AC Date Name Signature Performed by Approved by 36 SPEEDCOM SC5800 User Manual 5.7 SC5800 Test Record Parameter Unit Site A Site B Frequency channel plan: Transmit A/B/C/D Receive A/B/C/D If D – List Transmit and Receive Frequencies [MHz] Transmitter output power dBm Receiver input level (ON) Volts Receiver input level (ON) dBm Receiver input level (OFF) Volts Receiver input level (OFF) dBm Calculated input level dBm Fade margin dB Frame Lock indicator Color Fixed attenuator dB BER-test Hours BER Alarm Indicators Clear (Yes/No) Date Name Signature Performed by Approved by 37 SPEEDCOM SC5800 User Manual 38 SPEEDCOM SC5800 User Manual 6 NMS SOFTWARE 6.1 Introduction to the Network Management System The purpose of the Network Management System, hereafter called the NMS, is to allow you to configure, manage or interrogate the following primary functional elements of a Digital Radio Link (Local or Remote Stations within the link): • Indoor Unit • Outdoor Unit The NMS is a PC-based software package that provides you with a graphical interface that is used to perform on-site element management of a Microwave Digital Radio (SC5800) System. It allows you to configure, manage and interrogate the SC5800 System by selecting various menus and options. It provides extensive management functions on site and, via the microwave radio link, can be used to access the remote SC5800 station. The hardware as well as the software constituting the NMS is collectively called the NMS Terminal. The NMS Terminal is the principal system support equipment associated with the SC5800 System for system installation and commissioning. It connects to a designated NMS Terminal port (labeled Element Manager) on the front panel of the Indoor Unit of a SC5800 Station installation, by means of a serial data interface (this cable is supplied in the IU box). The NMS communicates with SNMP agent software that is contained in each SC5800 Indoor Unit. The NMS communicates with the agent’s software: the software enables a unit to interpret MIB (Management Information Base) commands via SNMP (Simple Network Management Protocol). 6.2 General Information 1. To select a button/option, simply click the appropriate button/option. 2. Move the mouse pointer to the different areas of the screen. When the pointer changes into a hand, this indicates that the area can be activated by a left mouse button click. In some cases (opto inputs, relays, payload interfaces), hold the mouse hand cursor over the particular area of the screen and a hint appears indicating the state associated with the selected item. If the pointer changes to vertical bar, then the field may be edited if clicked. 3. The main screen has pull-down menus that are activated by clicking on the words of the menu (menu items). 39 SPEEDCOM SC5800 User Manual 4. A general help facility is available by clicking on the Help button on the Main screen. This opens the help file for the Network Management System. From here, you can search for a particular topic using the Index facility or you can use the Find facility to search for key words connected to the specific information required. 6.2.1 Microwave Digital Radio A SC5800 link consists of at least one complementary pair of SC5800 stations that may be extended over longer distances by linking further station pairs in a multiplehop configuration. A single SC5800 station comprises an Indoor Unit and an Outdoor Unit interconnected by a data cable (CAT5) and a 2-core DC supply cable. 40 SPEEDCOM SC5800 User Manual 6.3 Main Screen Figure 6. RSSI as a function of RF input level This screen displays the names of the stations/sites, their IP addresses and allows you to view or edit the parameters and status for the entire station. Indoor Unit and Outdoor Unit details are accessed by using the mouse to select the Indoor Unit and Outdoor Units of the local or remote sites. Note that if the local Indoor Unit is offline, all controls for both station IUs and OUs are 'grayed out' and thus unavailable. If the Outdoor Unit is offline and the Indoor Unit is online, then only the Outdoor Unit controls are 'grayed out' and unavailable. The Main screen shows a local station on the left hand side of the screen and a remote station on the right hand side of the screen. The Main Menu area provides pull-down menus and controls that allow you to configure and monitor system link parameters and to perform basic tasks. The station elements are displayed initially with no colors, but the controls in the blocks change colors when the NMS attempts to communicate with the link’s primary elements. The control buttons on the screen are short -cuts to MIB elements in the Indoor Units. Move your mouse pointer to the required area of the screen and when the mouse pointer changes into a 'hand', click the right mouse button to display more detailed information. Click the left mouse button to activate relays and loopbacks. 41 SPEEDCOM SC5800 User Manual 6.3.1 Link Elements Areas The Link Elements Areas on the Main Screen show an abbreviated status of the Indoor and Outdoor Unit interfaces. Move your mouse pointer to each block until a hand appears and click the right mouse button (right click) to see more information on each element. If both Stations are online, the status bar at the bottom of the screen shows that the stations are being polled. If there is no communication with the remote side, the remote station will be grayed. If there is no communication with the local side’s Outdoor Unit, it will be gray. Display Indicators • A GREEN status indicator shows that there are no current alarms or errors. • A YELLOW status indicator shows that there was a historic alarm condition. • A RED status indicator shows that there is a current alarm condition. The main screen shows a RSSI (Received Signal Strength Indication) bar graph in dBm. 42 SPEEDCOM SC5800 User Manual 6.4 NMS Menus 6.4.1 Main Screen Menus The following pull-down menus are available from the Main menu: Menu Sub-item Result File Exit Exit from NMS. Options Communications Allows setup of which communications port is used on the PC or Laptop for communication with the Indoor Unit via the front panel Element Manager Serial Port. Local Trib Code It is possible to purchase upgrades for E1/T1 Indoor Units (upgrades to 2E1/T1 or 4E1/T1). The user contacts the factory and provides the Indoor Unit Bar Code number details. The factory then supplies a “Tributary Code”, unique to the Indoor Unit, which is entered using the MIB (Version 2 products) or using the NMS (Version 2 product). Remote Trib Code See above. Local User Configuration Allows the user to set the access control settings for the local station equipment to allow the user to log on as an ‘Administrator’ with full read/write configuration access or with ‘Readonly’ access. (Note: This option is only available if the IU firmware has been supplied with securefeatures activated – the default is NOT to have this feature activated). Remote User Configuration Allows the user to set the access control settings for the remote station equipment to allow the user to log on as an ‘Administrator’ with full read/write configuration access or with ‘Readonly’ access. (Note: This option is only available if the IU firmware has been supplied with securefeatures activated – the default is NOT to have this feature activated). Spectrum Analyzer Allows the user to examine the RF spectrum using a RSSI (received signal strength indicator) value measured in the Outdoor Unit. If interference exists, this feature allows the user to examine the spectrum and decide where to set the transmit and receive frequencies for the local and remote stations. 43 SPEEDCOM SC5800 User Manual 6.4.1.1 Exiting from the NMS: File/Exit You can exit from the NMS as follows: Click on the Exit option from the File pull-down menu on the Main screen. You are prompted for confirmation of the shutdown – answer OK or Cancel to this prompt. 6.4.1.2 Communications This menu item allows you to configure the following NMS communications parameters: • Serial Port • Polling Cycle The users can either: Use the Load Defaults option or change to the required settings and then use the Apply Changes button. Use the Exit button to exit without any changes being made. 6.4.1.2.1 Serial Port Configure the serial port as follows: 6.4.1.2.2 1. Select Communications from the menu on the main screen. 2. Select the required port: COM1, COM2, COM3 or COM4. Polling Cycle Set the polling cycle (minimum 3 seconds). This determines how often the information is updated. 6.4.1.3 Local User Configuration Allows the user to set the access control settings for the local station equipment to allow the user to log on as an ‘Administrator’ with full read/write configuration access or with ‘Read-only’ access (only available with “security-enabled” versions of Indoor Unit firmware). The user enters a ‘Username’, ‘Password’, ‘Access level’ and activates the user via an ‘Active’ input field. With ‘Administrator’ access, the user can add new users. Use the Apply Changes button once the changes are to be made in the Indoor Unit. Use the Exit button to exit without any changes being made. 44 SPEEDCOM SC5800 User Manual 6.4.1.4 Remote User Configuration This applies to the same directions above (that is, Section 6.3.1.3, Local User Configuration, page 44) but controls access to the remote station’s MIB. 6.4.2 Main Screen Short-cut Buttons Short-cut buttons are provided to allow quick access to the above menu items. 6.5 Indoor Unit Configuration The Indoor Units have graphical interface controls that allow you to configure the following items: • Payload Data Interface Port • Service Channel Port • ‘Loopback to Line’ and ‘loopback to RF Link’ • Opto Inputs • Relays Payload is from the user’s ‘line’ equipment to the Indoor Unit Payload Data DB25 connector and RF Link is from Antenna to Antenna. Right-click on the Indoor Unit to get the following options • Time/date entry • Station Status • Station Properties • Station Info (Serial number, software version, bootkernel version) • View Event Log • Maintenance 6.5.1 Controls 6.5.1.1 Payload Data Interface Port A label/name can be assigned to any of the payloads. 6.5.1.1.1 E1 Port Line Code Default setting is HDB3. However, it can be set to either HDB3 or AMI. 45 SPEEDCOM SC5800 User Manual 6.5.1.1.2 T1 Port Line Code Default setting is B8ZS. However, it can be set to either B8ZS or AMI. 6.5.1.2 Payload Error Monitoring Term Name Description AIS Alarm Indication Signal This is an all 1’s detection, incoming to the equipment on the payload tributaries. Note that there is independent monitoring for AIS on each of the 4 tributaries. LOS Loss of Signal This is a loss of signal detected on the input to the payload data port tributaries. Note that there is independent monitoring for LOS on each of the 4 tributaries. 6.5.1.3 Service Channel Port The service channel serial port provides a means to send asynchronous data across the link to the far side service channel port. Service channel ports can be connected back-to-back (i.e., Remote to Local) at a remote site so as to extend the channel in a multi-hop network. The service channel data is multiplexed with IP data onto the RF overhead link. Priority is given to IP data. • Use the Load Defaults option or change to the required settings and then use the Apply Changes button. • Use the Exit button to exit without any changes being made. 6.5.1.3.1 Baud Rate Default setting is 115200 bit/s (Ver 1, 2). 6.5.1.3.2 Data Width Default setting is 8 bits. 6.5.1.3.3 Parity Default setting is None. 6.5.1.3.4 Flow Control Default setting is None. 6.5.1.3.5 Stop Bits Default setting is 1 Bit. 6.5.1.4 Relay Scripting (NA for Version 2 releases) Note: THIS MANUAL ADDRESS FEATURES SPECIFIC TO VERSION 2 OF THE SPEEDCOM SC5800 PLEASE IGNORE REFERENCES TO OTHER VERSIONS. 46 SPEEDCOM SC5800 User Manual Configure the various alarms that will switch on Indoor Unit relays as required. There are two relays on each Indoor Unit. Each relay can be programmed to switch on based on the occurrence of Payload or RF Link errors detected in the LOCAL/NEAR and/or REMOTE/FAR Indoor Units. The user can visually select those errors that will trigger the respective relays. The following built-in test status can be monitored on a link: RF Link Link Unavailable Frame Unlock Minor PER Exceeded ESR Exceeded Payload Interface LOS AIS • Use the Apply Changes button to change settings. • Use the Exit button to exit without any changes being made. 6.5.1.5 Indoor Unit Loopback Controls These controls allow you to set the loopbacks on the payload data. • IU Loopback to Line - Used to loopback the data on the payload interface so that incoming user payload data is sent straight back to the user. The payload data does not go out over the RF link. • IU Loopback to RF Link - Used to loopback the payload (Indoor Unit)/Outdoor Unit data so that payload data arriving over the RF link is looped and sent back across the RF link. Perform a loopback as follows: 1. Select the Loopback Type by choice of arrows on the IU being tested. 2. Select the Loopback Timeout Time (in seconds). If enabled, the Loopback state will cancel after Time seconds and the unit will return to normal operation. 3. Click on the Loopback Timeout Enable checkbox. 4. Click on the Apply Changes button. 47 SPEEDCOM SC5800 User Manual 6.5.2 Menu Items 6.5.2.1 Date/Time Entry In this menu, the user has the option of entering the: • Date (change date using the calendar display) • Time (change time using the spin button on the right-hand side of the control or enter manually). • The user had the option of ‘fetching’ the date and time from the PC or Laptop and using this information. • Use the Apply Changes button once the update in the Indoor Unit is to be made. 6.5.2.2 Station Status 6.5.2.3 General Status Indicators These errors occur during the phase of continuous error checking. Errors are latched until the operator clears them on the NMS. The following is a list of possible error indicators as well as the possible faults and corrective actions to solve each error. Error Displayed Possible Faults and Corrective Actions General Faults Outdoor Unit Not Responding • The Outdoor Unit simply doesn't respond to any messages sent to it by the Indoor Unit. The Outdoor Unit could possibly be damaged or the cables to the Outdoor Unit are disconnected from the Indoor Unit or damaged. Outdoor Unit Comms Error • Message from Outdoor Unit too long (data corruption). • Received message frame invalid – the Outdoor Unit messages follow a strict data link layer frame protocol. There could data corruption. • Partial message received from Outdoor Unit - remainder did not arrive in time (Outdoor Unit switched off?). • CRC Error – data corruption. • Software queuing/buffering errors in the Indoor Unit firmware. • Wayside port queue overruns - too high data rates or failed overhead link. • Comms Error - errors caused by Rx Overrun (Indoor Unit processor could not service the received characters fast: too high data rates), parity error if odd or even parity enabled (data corruption or incorrect configuration), framing error (no valid stop bit where one was expected - invalid baud rate or data width or parity configuration or data corruption) or break detected (line shorted causing permanent break or corruption). Wayside Port Comms Error 48 SPEEDCOM SC5800 User Manual Overhead Link Comms Error • Overhead PPP link error: the buffering system of the overhead link cannot process data fast enough and received messages have been discarded (the software cannot process the data fast enough). Ethernet Comms Error • The buffering system of the interface cannot process data fast enough and received messages have been discarded (the software cannot handle the data fast enough). Element Manager Comms Error • Message from PC or laptop too long (data corruption). • Software queuing/buffering errors in the NMS firmware. Alarm 1 on • A digital optically isolated input used for general site alarm monitoring (Auxiliary Input 1). Alarm 2 on • A digital optically isolated input used for general site alarm monitoring (Auxiliary Input 2). 6.5.2.3.1 Power-up Self Test Indicators The following is a list of errors that can occur during the power-up phase of operation. These errors may only be cleared by switching the Indoor Unit off and then on again. The list also describes the possible faults and corrective actions to solve each error. Error Possible Faults and Corrective Actions FLASH The Application FLASH memory test failed. Only a faulty Application Flash device can cause this fault and the Application Flash device will have to be replaced. DRAM Error The DRAM test failed. Only a faulty DRAM device can cause this fault and the DRAM will have to be replaced. SRAM Error The battery-backed up SRAM test failed. Only a faulty SRAM device or battery can cause this fault and the Battery and/or SRAM will have to be replaced. Watchdog Reset Software error. Please contact the supplier. Processor triggered a watchdog restart because watchdog is no longer being toggled by the application. Either the application has become too overloaded or this is a software or design fault. Hard Reset A hardware reset was performed. This is an indication of the last reason for a reset and does not constitute a fault condition. Unknown Reset Another reset detected by the Indoor Unit’s microprocessor (other than Watchdog and Hard Reset) was performed. This is an indication of the last reason for a reset and does not constitute a fault condition. Line Interface Error The line interface transceiver is not responding as expected and is most likely faulty. The transceiver is programmed for operation and then checked to see that the values programmed are valid (read correctly). FPGA The FPGA register interface is not responding correctly and is most likely faulty. The FPGA is programmed for operation and then checked to see that the values programmed are valid (read correctly). Real Time Clock The Real Time Clock (RTC) is not responding correctly and is most likely faulty. The RTC is programmed for operation and then checked to see that the values programmed are valid (read correctly). Note: Use the Clear button to clear alarm indicators. 49 SPEEDCOM SC5800 User Manual 6.5.2.4 Station Properties In this menu, the user has the option of entering the: • Indoor Unit Station name • IP address of the Indoor Unit • Netmask Note: Use the Apply Changes button once the update in the Indoor Unit is to be made. 6.5.2.5 Station Info • This information allows you to view the build state details of the primary hardware and software components of the selected Indoor Unit. Information provided is read from the Indoor Unit microprocessor. • Serial Number (Programmed into the Indoor Unit at time of manufacture), • Software Version (Programmed into the Indoor Unit during any software upgrade) and • Bootkernel Version Number (Programmed into the Indoor Unit at time of manufacture). 6.5.2.6 Indoor Unit Event Log This screen is used for the viewing of the event log file. In the event of a pers istent field fault, it will be useful for you to save the logged data file and send it (with the faulty unit) to the repair department to assist in the repair of the unit. There is a maximum of 100 records stored in the Indoor Unit (one filled, earlier records are discarded in favor of newer records). The event log file is displayed from oldest to youngest (i.e., ascending order by time). The log file columns are: • Date – the date of the event dd-mm-yyyy. • Time – the time of the event in hh:mm:ss. • Type – the type of event. • Event – a text description of the event itself. Notes: • Use the Clear Log button to clear the log in the Indoor Unit. • Use the Refresh button to collect the log from the Indoor Unit. • Use the Save button to save the log on the NMS PC or Laptop platform. • Use the Exit button to exit the Event Log menu. 50 SPEEDCOM SC5800 User Manual 6.5.2.7 Maintenance This screen provides the ability to upgrade the Indoor Unit firmware on the local/near Indoor Unit only. The user selects the file to be uploaded using the Select File button. A file selection dialogue is presented which provides a means to retrieve the file from any directory on any drive. Once the file is selected, the following information is displayed on the screen: • Application version - the Indoor Unit application code software version number as read from the Indoor Unit application). • Date and time - the Indoor Unit application code software date as read from the Indoor Unit application. • Bootkernel version - the Indoor Unit boot kernel code software version number as read from the boot kernel. Upload Status box Used to display the steps being undertaken during the programming and verification process. As the upload process proceeds, the user is informed of progress. Verification of upload is done once the file has been uploaded into DRAM. Thereafter, the data is loaded into ‘Application Flash’. The latest version is uploaded into one ½ of the flash device. The other half maintains the old version. In this way, there is an option to revert to the old version should there be an upload problem. 6.5.2.7.1 Programming an Indoor Unit This procedure allows you to program factory-supplied firmware into the Application Flash IC on the Indoor Unit. Proceed as follows: 1. Switch off the Indoor Unit. Run the NMS application and connect to the Indoor Unit via the Element Manager Port. 2. Select the file to be uploaded into the Indoor Unit. 3. Switch on the Indoor Unit. 4. The upload process will proceed and the user is informed of the progress via the status box. 5. Once complete, the IU verifies the program code is valid. 6. Once verified, the data is transferred into the IU’s Application Flash. 7. Once the code is programmed, the Indoor Unit application is restarted by the boot kernel. 51 SPEEDCOM SC5800 User Manual 6.6 Outdoor Unit Configuration 6.6.1 Controls 6.6.1.1 Loopback Controls These controls allow you to set the loopbacks on the payload data. • OU Baseband Loopback - Used to loopback the data at baseband processor level in the Outdoor Unit so that incoming user payload data is sent back to the user via the IU/OU interconnection data cable. • OU RF Loopback - All RF data sent out of the Local Indoor Unit to the Outdoor Unit is looped back at the output stage of the Outdoor Unit and returned to the Indoor Unit. Perform a loopback as follows: 1. Select the Loopback Type by choice of arrows on the OU being tested. 2. Select the Loopback Timeout Time (in seconds). If enabled, the Loopback state will cancel after Time seconds and the unit will return to normal operation. 3. Click on the Loopback Timeout Enable checkbox. If not enabled, then only the NMS can cancel the loopback condition. 4. Click on the Apply Changes button. 6.6.2 Menu Items 6.6.2.1 Station Configure The current Outdoor Unit parameters for Channel plan, Transmit Power and Autorecovery are displayed. All Outdoor Unit operational parameters are stored in the Indoor Unit. The Outdoor Unit is unaware of what it has been programmed to do. The operational parameters are programmed automatically after a power up. This screen allows you configure the following Operational Outdoor Unit parameters: • Frequency channel Plan. • Transmit Power. 52 SPEEDCOM SC5800 User Manual 6.6.2.1.1 Frequency Channel Plan The SC5800 Radios operate in the 5.725 GHz to 5.850 GHz ISM frequency band. The SC5800 has predefined frequency channel plans (termed A, B, C and D). 6.6.2.1.2 Transmit Power The Transmit power ranges from 2 to 24 dBm. There is also a mute setting. 6.6.2.1.3 Autorecovery This feature is used if the user is installing a link from one side and there is no technical staff assistance on the opposite side of the link. It mitigates against the link failing and not being able to be re-established. If autorecovery is enabled, the required operational RF parameters are programmed into the Outdoor Units by the local and remote Indoor Units. If communication between the two Indoor Units has not reactivated within 5 seconds, the previous (working) ‘default’ RF parameters are programmed into the respective Outdoor Units. 6.6.3 OU Station Info The OU Station Info screen provides a brief report of the build state of the Outdoor Unit: • Serial number – loaded into the Outdoor Unit at time of manufacture. • Software version – loaded into the Outdoor Unit at time of manufacture. • High Band Transmitter – affects the way the channel plan is implemented on the Outdoor Unit. • Low Band Transmitter – affects the way the channel plan is implemented on the Outdoor Unit. • FCC Regulations (None, FCC, Other). 6.6.4 Outdoor Unit Status This screen allows you to view the following Outdoor Unit status information: • Last Restart. This indicates the reason why the Outdoor Unit restarted (e.g., Power On, Watchdog Timeout). • OU Lock Detect Status: indicates if there is a loss of lock of the IF, Transmit or Receive path phase-locked oscillators in the OU. 53 SPEEDCOM SC5800 User Manual 6.7 RF Link Error Status Monitoring Selected by right-clicking the relevant antenna and choosing the Diagnostics/Error option. 6.7.1 RF Link Status Link Unavailable The RF Link is considered not available (see Link Availability definition on next page). Frame Unlock RF link only. It looks at data received from the link. If the link is quality is poor ( i.e., high PER at the RF level, ‘Frame Unlock’ is the result). AIS is sent from the transceiver (from link direction) as long as ‘Frame Unlock’ is true and no reliable data is available. Packet Error Rate Fault The PER Monitoring has been enabled and the Instantaneous PER has exceeded the configured PER Fault Threshold for the RF link. ESR Exceeded RF Errored Second Ratio has been exceeded due to Packet errors on the RF link. SESR Exceeded RF Seriously Errored Second Ratio has been exceeded due to Packet errors on the RF link. BBER Exceeded RF Background Block/Packet Errors Ratio has been exceeded due to block errors on the RF link. Default RF Parameters Activated The Operational RF param eters were programmed into the Outdoor Unit by the local and remote Indoor Units. Communication between the two Indoor Units has not reactivated within 5 seconds. To recover communication the Indoor Unit has selected the ‘Default’ RF parameters and programmed the Outdoor Unit with them. 6.7.2 Packet Error Rate Thresholds Packet error rate (PER) is calculated as the ratio of the number of uncorrectable blocks over the number of blocks transmitted per second. Three PER thresholds are provided for each monitored link, these are: • Minor PER Threshold – this threshold defaults to 0.0002 and triggers an alarm if the calculated PER exceeds this value. • Major PER Threshold – this threshold defaults to 0.02 and triggers an alarm if the calculated PER exceeds this value. • Fault PER Threshold – this threshold defaults to 2.0 and triggers an alarm if the calculated PER exceeds this value. 54 SPEEDCOM SC5800 User Manual 6.7.2.1 G.826 Thresholds Three G.826 thresholds are provided for each monitored link. Each of these ratios is calculated once every second and will trigger a fault condition if the ratios exceed the programmed thresholds that are: • Errored Second Ratio Threshold – this threshold which defaults to 4 X 10-2 triggers an alarm if the calculated ESR exceeds this value over the measurement period (Report Time). • Severely Errored Second Ratio Threshold – this threshold which defaults to 2 X 10-3 triggers an alarm if the calculated SESR exceeds this value over the measurement period (Report Time). • Background Block Error – this threshold which defaults to 6.25 X 10-2 triggers an alarm if the calculated BBER exceeds this value over the measurement period (Report Time). 6.7.2.2 Link Availability A period of unavailable time begins at the onset of ten consecutive SES events. These ten seconds are considered to be part of unavailable time. A new period of available time begins at the onset of ten consecutive non-SES events. These ten seconds are considered to be part of available time. The figure below illustrates this definition. Figure 7. Link Availabity 6.7.3 RF Link Error Monitor The Link Error Monitor screen provides the user with detailed Packet Error Rate (PER), G.826 and link availability monitoring for the RF link. There is a status field, Total Seconds, which applies to the link. Total Seconds is the total number of seconds since the counts were last cleared. It is used to determine available and unavailable seconds on a link. 6.7.3.1 General • Errored Blocks Counter - containing the number of blocks containing errors accumulated until cleared. • Errored Seconds Counter - containing the number of seconds containing errored blocks since the counters were last cleared. 55 SPEEDCOM SC5800 User Manual • Severely Errored Seconds Counter - a counter containing the number of seconds containing more than 30% errored blocks since the counters were last cleared. • Background Block Errors Counter - a counter containing the number of blocks received in error excluding those contributing to severely errored seconds since the counters were last cleared. • Error Second Ratio – a ratio of the number of errored seconds to the total number of seconds since the counters were last reset. • Severely Error Second Ratio – a ratio of the number of Severely errored seconds to the total number of seconds since the counters were last reset. • Background Block Error Ratio – a ratio of the number of Background Blocks in errors to the total number of blocks received since the counters were last reset. • Corrected Symbols field shows the number of symbols that have been corrected by the FEC device within the Indoor Unit. 6.7.3.2 Packet Error Rate • Instantaneous Ratio - This is the number of errored blocks as determined by the FEC on the RF Link, divided by the total number of blocks per second for that link. If the instantaneous PER exceeds the minor or major PER thresholds, a fault is triggered and a RF Link error is indicated on the Indoor Unit Front Panel. • Maximized Ratio - The highest Packet error rate reached since the errors were last cleared. 6.7.3.3 Link Availability • Available Seconds – the number of seconds the link has been available since counts were last cleared. • Unavailable Seconds – the number of seconds the link has been unavailable since counts were last cleared. 56 SPEEDCOM SC5800 User Manual 7 MAINTENANCE INFORMATION 1. The user is advised to refer to the Technical Data section for details on IU/OU interconnection cables (customer-furnished). 2. The “Ordering Information” paragraph in the Technical Data section provides details on part numbers for items that can be ordered. 3. Section 4 of this manual lists customer furnished equipment that should be used for installing the SC5800 product. 4. There are two options to control the SC5800 product via SNMP. a. One uses any open-standard-compliant SNMP Management package (HP OpenView, SNMPc etc): in this case, one has access to the full compliment of the product's MIB elements. b. The NMS application package supplied with the product accesses a subset of the MIB. It has a graphical user interface carefully designed to assist installation and maintenance staff. 57 SPEEDCOM SC5800 User Manual 58 SPEEDCOM SC5800 User Manual 8 TECHNICAL DATA 8.1 Environmental Requirements 8.1.1 Outdoor Equipment Operating temperature: -30°C to +60°C Relative humidity: 8-100% Atmospheric pressure: 0.7 to 1.06 kPa Lightning protection ITU-T K.20 8.1.2 Indoor Equipment Operating temperature: 0°C to +50°C Relative humidity: 5-90% Lightning protection: ITU-T K.20 8.2 Mechanical Information for Outdoor Equipment 8.2.1 SC5800 Outdoor Unit Dimensions (HxWxD): 335mm x 231mm x 124mm Weight: 5.9 Kg 8.3 Mechanical Information for Indoor Equipment Dimensions (HxWxD): 45mm x 480 mm x 265mm Mounting: 19” Rack, 1U high or Table top Weight: 2.9 Kg 8.4 Power Supply Requirements DC power supply: 21 to 56 VDC DC power supply grounding: Positively or negatively grounded Power consumption: 35 W typical, 45 W maximum. 59 SPEEDCOM SC5800 User Manual 8.5 Electrical Performance 8.5.1 General Characteristics Frequency Range: 5725 to 5850 MHz Data Capacity: E1 (2.048 Mbps), T1 (1.544 Mbps/s) 2E1 : 2T1 4E1 : 4T1 RF Channel Bandwidth: 17 MHz Go/Return spacing: Can be adjusted, as fixed go-return spacing is NOT mandatory in the ISM license-free bands. Modulation: CCK Processing Gain: 11 dB Frequency Channel Plan A: 5735 and 5804 MHz Frequency Channel Plan B: 5753 and 5822 MHz Frequency Channel Plan C: 5771 and 5840 MHz Transmission Delay: 600 us maximum for radios only (one-way) 8.5.2 Transceiver Characteristics 8.5.2.1 Frequency Band: Low-band Outdoor Units Transmit band: 5725 – 5787 MHz Receive band: 5787 – 5850 MHz 8.5.2.2 Frequency Band: High-band Outdoor Units Transmit band: 5787 – 5850 MHz Receive band: 5725 – 5787 MHz 60 SPEEDCOM SC5800 User Manual 8.5.3 RF Interface Transmitted Power +2 to +24 dBm, software adjustable (incl. mute) Receiver Sensitivity: 4E1/4T1: -88dBm for PER = 10 -6 Maximum Receive Level: -30dBm 8.5.4 Payload Data Interfaces 8.5.4.1 1, 2 or 4 (i.e., nE1) Interface Data Rate: Full duplex E1 (2.048Mbit/s), 2E1 or 4E 1 Digital Interface: ITU-T G.703 Connectors: Balanced 110 ohm on DB25 Line code: HDB3 or AMI selectable Jitter and Wander: ITU-T G.823 8.5.4.2 1, 2 or 4 (i.e., nT1) Interface Data Rate: Full duplex T1 (1.544Mbit/s), 2T1 or 4T1 Digital Interface: DSX-1, G.703 compliant Connectors: Balanced 110 ohm on DB25 Line code: AMI or B8ZS selectable Jitter and Wander: ITU-T G.823 61 SPEEDCOM SC5800 User Manual 8.5.5 Auxiliary Input Interface (CONTACT CLOSURE) Number of Inputs: Maximum voltage: 12V Logical zero: Short from input to return pin Logical one: Open input to return pin 8.5.6 Auxiliary Output Interface Number of outputs: States: Normally -open and normally-closed Contact rating: DC: 220 V, 1 A, 60 W AC: 250 V, 1 A, 125 VA 8.5.7 Wayside channel interface Interface standard: RS232, DCE Hands haking: None, Hardware Port rate: 115,200 bps 8.5.8 Element Manager Port Interface Interface standard: RS232, DTE Handshaking: Hardware Data rate: 115,200 bps 8.5.9 Indoor/Outdoor Unit Interface The physical interface between the Indoor and Outdoor Unit is IEEE802.3 Ethernet. As such, the same considerations that apply between standard routers/switches/hubs and PC LAN cards should be adhered to when selecting lengths of cables between the OU and the IU. Cable lengths of up to 120 meters have been tested in a laboratory environment. 62 SPEEDCOM SC5800 User Manual The following table lists information to assist the user to select cables to be used between the Indoor and Outdoor Units. Interconnecting cable Data General Requirements STP (FTP) 4 Pairs Solid Cat 5, PVC FR UV protected Polifin H2/J263/904 Outer Black. Outer diameter of cable: 7.3mm ± 0.5mm. (This is an “upjacketed” STP 4 Pair cable.) Examples: 1. 2. 3. 4. 5. Mohawk CAT5 P/N 57041 Superior Essex BBDN CAT 5 cable P/N 04-0010-34 (7.8mm) Superior Essex CAT 5 P/N 18-241-31 18-241-11 (5.1mm) General Cable CAT 5 P/N 2137113 2137114 (5.6mm) Belden CAT 5 P/N BC1002 (6.0mm) For the cables that have diameters less the required OD, one can use one or two pieces of heatshrink on the cable where it passes through the gasket. Interconnecting cable Power General Requirements Power 1.5mm sq stranded PVC Insulated, PVC FR UV protected Polifin H2/J263/904 Outer Black 300/500V Temp -20°C to +85°C. Cable outer diameter: between 7.4mm and 9mm i.e. 8.2mm ± 0.8mm. Examples: Superior Essex type SJOOW flexible cable P/N 441821* (7.4mm) Carol Cable (General Cable) SJOW/SJO P/N 02001 18 gauge 2 conductor (7.8mm) 63 This is a standard FTP Cat 5 cable that is ‘upjacketed’ with suitable plastic for FR/UV (Flame retardant/Ultra Violet) protection. SPEEDCOM SC5800 User Manual 8.6 Ordering Information Terminal Information Terminals* Product Description D1-58-HB-5800 651-03853ET1HB SPEEDCOM SC5800 1x T1/E1 (High Band) D1-58-LB-5801 651-03853ET1LB SPEEDCOM SC5800 1x T1/E1 (Low Band) D2-58-HB-5802 651-03853ET2HB SPEEDCOM SC5800 2x T1/E1 (High Band) D2-58-LB-5803 651-03853ET2LB SPEEDCOM SC5800 2x T1/E1 (Low Band) D4-58-HB-5804 651-03853ET4HB SPEEDCOM SC5800 4x T1/E1 (High Band) D4-58-LB-5805 651-03853ET4LB SPEEDCOM SC5800 4x T1/E1 (Low Band) Notes: • Complete link requires two radios: one must be High Band (HB) and the other a Low Band (LB). • SC5800 operates from 21 - 56 VDC. For operation using AC power, please order item # 651-03864 (Bench AC Power Supply). • Each radio includes a 10Base-T Ethernet interface in addition to the primary payload and provides a 2 Mb wayside Ethernet channel. Accessories & Upgrades Part Number Description 651-03864 Bench Power Supply 110-220VAC to 48VDC 651-03865 SC5800 Upgrade 1xE1/T1 to 2xE1/T1 651-03866 SC5800 Upgrade 2xE1/T1 to 4xE1/T1 651-03867 SC5800 Upgrade 1xE1/T1 to 4xE1/T1 The SC5800 uses standard CAT5 Ethernet cable and RJ-45 connectors for connecting the Indoor Unit to the Outdoor Unit. A two-wire power cable is also required between the Indoor Unit and the Outdoor Unit. Note Screened Cat5 cable and UV resistant cables are recommended for long-term outdoor use. 64 SPEEDCOM SC5800 User Manual Microwave Digital Radio System Spare Parts for SC5800 Part Number Description 651-03810ET1 SC5800 Indoor Unit 1xE1/T1 - Spare Part 651-03810ET2 SC5800 Indoor Unit 2xE1/T1 - Spare Part 651-03810ET4 SC5800 Indoor Unit 4xE1/T1 - Spare Part 651-03806LB SC5800 Low Band Outdoor Unit - Spare Part 651-03806HB SC5800 High Band Outdoor Unit - Spare Part 651-03868 SC5800 NMS Software Disk - Spare Part 651-03809 SC5800 ODU Pole Mounting Kit - Spare Part 862-01881 SC5800 Digital Radio System User Manual - Spare Part 660-03405 SC5800 Cable Assembly: RSSI Test Loom - Spare Part 65 SPEEDCOM SC5800 User Manual SC5800 Ordering Information: Note: For Terminal part numbers, see page 64. Each SC5800 radio includes the following: Part No 651-03810ET1 or Description QTY SC5800 Indoor Unit: 1xE1/T1or 2xE1/T1 or 4xE1/T1 SC5800 Outdoor unit 651-03809 SC5800 ODU Pole Mounting Kit 862-01881 SC5800 Digital Radio System User Manual 651-03868 NMS Software Disks 660-03405 RSSI Cable 651-03810ET2 or 651-03810ET4 651-03806HB or 651-03806LB It is possible to purchase upgrades for E1/T1 Indoor Units (upgrades to 2E1/T1 or 4E1/T1). The user contacts the factory and provides the Indoor Unit Bar Code number details. The factory then supplies a “Tributary Code”, unique to the Indoor Unit, which is entered using the MIB (Version 2 product) or using the NMS (Version 2 product). Note: SC5800 only comes in Version 2. 66 SPEEDCOM SC5800 User Manual 9 APPENDIX A: ELEMENT MANAGER PORT POINT-TOPOINT SERIAL COMMUNICATIONS SETUP This appendix summarizes how to set up a network connection (using PPP) between a computer and the SC5800 Indoor Unit’s Element Manager port. It lists how the connection can be setup and configured to allow data transfer and SNMP-based control of the SC5800 Indoor Unit. Note: For both NT and Win 95 or 98 machines, check that a Network Adapter is installed. The following screen capture shows the Windows help available to assist setting up a serial comms network adapter. This screen appears when the Help function is activated. 67 SPEEDCOM SC5800 User Manual 9.1 Adding a Modem: Windows NT 1. When working with a PC running a Windows NT, add a modem using the following screen as a guideline. Click the Modems icon. 2. Verify your modem, or click Add to include another modem. 68 SPEEDCOM SC5800 User Manual 3. Follow the directions in the screen capture below and click Next. 4. Locate the manufacturer and model of your modem and click Next. 69 SPEEDCOM SC5800 User Manual 5. Windows verifies the modem selected. Select the option on which you want to install the port (i.e., Selected ports option). When the COM port has been selected, click Next. When completed, click Finish. 70 SPEEDCOM SC5800 User Manual 71 SPEEDCOM SC5800 User Manual 9.2 Adding Dial-up Networking: Windows NT 9.2.1 To add dial-up networking 1. From the desktop, double-click the My Computer icon. The following screen will be displayed. Next, double-click the Dial-up Networking icon (as displayed in the screen capture below). 2. The following windows are displayed: 72 SPEEDCOM SC5800 User Manual 3. Whether COM1 or COM2 is selected from the RAS Capable Devices drop-down list (see previous screen, setup the connection using the following screens as a guideline. This allows establishment of a PPP connection between the computer and the SC5800 Indoor Unit’s Element Manager port. 73 SPEEDCOM SC5800 User Manual 74 SPEEDCOM SC5800 User Manual 75 SPEEDCOM SC5800 User Manual 76 SPEEDCOM SC5800 User Manual 9.3 Adding a Modem: Windows 95/98 1. When working with a PC running a Windows 95/98, add a modem using the following screens as a guide. 2. Use the mdmnull.inf to add a serial cable modem connection capability to the PC or laptop. 77 SPEEDCOM SC5800 User Manual 3. Once setup, use the following screens to set up the COM port’s parameters. 78 SPEEDCOM SC5800 User Manual 9.4 Adding Dial-up Networking: Windows 95/98 1. After adding the modem, set up the connection properties using the following screens as a guide. This will allow establishment of a PPP connection between the computer and the SC5800 Indoor Unit’s Element Manager port. A Null_Modem connection option as shown below will be created. If one doesn’t exist, double-click the Make New Connection icon (as circled below). 79 SPEEDCOM SC5800 User Manual 80 SPEEDCOM SC5800 User Manual 10 APPENDIX B: MANAGEMENT OF THE SC5800 All management of the SC5800 product is implemented using SNMP (Simple Network Management Protocol), an open standard. The SC5800 product can be managed by: 1. Standard SNMP managers such as HP OpenView or SNMPc (i.e., there is Open Network Management compatibility). 2. For rapid product installation, the NMS GUI Application (hereafter referred to as the NMSGA) provides extensive management functions on site and, via the microwave radio link, can be used to access the SC5800 station on the opposite side of the link. The SC5800 NMS-GA is a software application that runs on a PC workstation such as a laptop or notebook computer that is connected to an SC5800 Indoor Unit (IU) serial port (DB9 DTE) or an Ethernet connection (10BaseT DTE) (both accessed via the IU front-panel). 10.1 SNMP and the SC5800 Use of SNMP within the product allows remote: configuration, monitoring of performance, notification of alarms and firmware upgrades via an IP-network. Within an IP network supporting routing of IP data, the radios can be supported from any remote location. The product can be accessed via the Internet if the necessary gateways are provided. A GSM/PCS modem dial-up capability provides another remote management option. The SPEEDCOM (SC) Indoor Units have built-in SNMP agents and an extensive MIB (Management Information Base). The SC5800 product uses SNMP V1 (RFC1155, 1157). The user has access to an Enterprise MIB (obtainable though customer services) and MIB II (RFC 1213). Access to the MIB via the IU SNMP agent is via Ethernet (10BaseT interface on the product's front panel) or PPP (RFC 1661) via the product's serial channel Element Manager port. The use of SNMP provides flexibility for operators with central equipment monitoring. It provides management access to radio configuration (all data interfaces), interface status and statistics, fault and maintenance information. SNMP security (if enabled) is ensured by using a login and password to give the user administrator or basic user rights (a standard user rights option limits the ability to SET MIB variables). The product has threshold-based alarm generation (there is an extensive SNMP trap list with a trap filter that is adjustable via SNMP). Network access (wired or wireless (i.e., GSM/PCS Modem) allows over-the-air remote firmware uploading (FTP) with a load verification (and reversion) capability. 81 SPEEDCOM SC5800 User Manual There are three principle requirements to use SNMP with the SC5800 Radio Stations. 1. A Management Station that runs a SNMP Management Software package that is installed on a networked or stand-alone PC that can be connected to an Indoor Unit either using a serial connection or an Ethernet connection. From the Management station, the agents within the SC5800 Indoor Units can be configured or polled for information. 2. Agent: The agent accepts SNMP GET, SET or GET-NEXT commands from the Management Application software and collects or adjusts information from the Indoor Unit's MIB. 3. Management Information Base (MIB): the MIB is a database that is accessed based on the OID (object ID) the SNMP Manager has chosen. The SPEEDCOM (SC) Indoor Unit used an Enterprise MIB and a standard MIB (MIB II) to store or allow access to information relevant to the SPEEDCOM (SC) Link. 82 SC5800 User Manual 10.2 The MIB Elements – OID (Object ID) DESCRIPTIONS Object ID Group Iso 1.3 Org 1.3.6 dod 1.3.6.1 internet 1.3.6.1.4 private 1.3.6.1.4.1 enterprises 1.3.6.1.4.1.1316 Wave Wireless 1.3.6.1.4.1.1316.1 products 1.3.6.1.4.1.1316.1.1 digitalradio 1.3.6.1.4.1.1316.1.1.1 mdrmte 1.3.6.1.4.1.1316.1.1.1.1 mdrmtePerformance 1.3.6.1.4.1.1316.1.1.1.1.1 mdrmtePayloadPerf Object Type Access Description 1.3.6.1.4.1.1316.1.1.1.1.1.1 mdrmtePpTable SEQUENCE 1.3.6.1.4.1.1316.1.1.1.1.1.1.1 mdrmtePpEntry SYNTAX 1.3.6.1.4.1.1316.1.1.1.1.1.1.1. mdrmtePpIndex INTEGER 1.3.6.1.4.1.1316.1.1.1.1.1.1.1. MdrmtePpLOS INTEGER read-only A Loss of Signal has been detected on the input to a tributary - there are four, one for each tributary. 1.3.6.1.4.1.1316.1.1.1.1.1.1.1. MdrmtePpAIS INTEGER read-only An Alarm Indication Signal has been detected on the input to a tributary - there are four, one for each tributary. 1.3.6.1.4.1.1316.1.1.1.1.1. 2 mdrmteCrcErrors† INTEGER read-only "The number of CRC4 or CRC6 errors seen on the selected tributary since the last time errors were cleared." 1.3.6.1.4.1.1316.1.1.1.1.1.3 mdrmteCrcTribSelect† INTEGER Rd-Write "The tributary selected for CRC checking." 1.3.6.1.4.1.1316.1.1.1.1.1.4 mdrmteCrcLock† INTEGER read-only "Indication of whether the CRC checking algorithm has locked onto a CRC frame signature in the payload data." 1.3.6.1.4.1.1316.1.1.1.1.1.5 MdrmteC rcEbit† INTEGER read-only "Reflects the status of the 'E' bits in the frame." INTEGER read-only Indicates if a RF Carrier has been detected by Outdoor Unit – if so, the header in the RF Packet has been identified as a potential valid packet - note however, that it could be received from another transmitter that uses the same 1.3.6.1.4.1.1316.1.1.1.1.2 mdrmteRFLinkPerf 1.3.6.1.4.1.1316.1.1.1.1.2.1 mdrmteCarrierDetect 83 SC5800 User Manual Object ID Group Object Type Access Description header format. 1.3.6.1.4.1.1316.1.1.1.1.2.2 MdrmteRSSI † 2 Gauge read-only A dBm value representative of the received signal level. The value detected is representative of the level that would be measured should a CW signal be input at the Outdoor Unit's Diplexer RF Port - a Spread Spectrum signal will appear to be 20 dB lower. The NMS makes an adjustment for this by using a 20 dB offset (addition to the Indoor Unit MIBindicated value). 1.3.6.1.4.1.1316.1.1.1.1.2.3 mdrmteCurrentPER DisplayString read-only This is the current Packet Error Rate and is based on the number of uncorrectable packets/blocks being detected by the FEC (Forward Error Correction) circuitry within the Indoor Unit (based on the number of errored packets divided by the total number of packets transmitted in a measurement period of 250msec). 1.3.6.1.4.1.1316.1.1.1.1.2. 4 mdrmteMaximizedPER DisplayString read-only This is the maximum Packet Error Rate detected during the last measurement period, based number of maximum number of uncorrectable packets/blocks detected by the FEC circuitry within the Indoor Unit. 1.3.6.1.4. 1.1316.1.1.1.1.2.5 mdrmteLinkUnavailable INTEGER read-only Based on G.826 criteria, this MIB element indicates RF Link Availability/Non-availability. 1.3.6.1.4.1.1316.1.1.1.1.2.6 mdrmteFrameUnlock INTEGER read-only The data that is transmitted across the RF Link is conveyed in a frame, compiled within the Indoor Unit's FPGA. The received data frame is examined to see that the frame, with a suitable format has been received. 1.3.6.1.4.1.1316.1.1.1.1.2.7 mdrmteRemoteFrameUnlock† INTEGER read-only Frame-lock (mdrmteFrameUnlock) as seen by the other end of the link is fed back here. 1.3.6.1.4.1.1316.1.1.1.1.2.8 MdrmteErrSecRatioExceeded INTEGER read-only The ESR is a ratio of the number of Errored seconds (one second periods within which uncorrectable packets were counted by the FEC IC) to the total time in seconds. 1.3.6.1.4.1.1316.1.1.1.1.2.9 mdrmteSevErrSecRatioExceeded INTEGER read-only The SESR is a ratio of the number of Severely Errored seconds (one second periods within which 30% of packets over the RF Link had uncorrectable errors) to the total time in seconds. † indicates Version 2.00 MIB additions/name changes 84 SC5800 User Manual Object ID Group Object Type Access Description 1.3.6.1.4.1.1316.1.1.1.1.2.10 mdrmteBkgrndBlkErrRatioExceeded INTEGER read-only The BBER is a ratio of the number of uncorrectable blocks/packets received to the total number of packets received. 1.3.6.1.4.1.1316.1.1.1.1.2.11 MdrmteMinorPERExceeded INTEGER read-only This parameter indicates if the minor packet (uncorrectable by FEC) error rate has been exceeded based on the defined threshold listed in the mdrmteFAULT mdrmtePerfTrapThreshold group. A GH filter is applied to the calculation. This GH filter functions as a weighted average where the GH Average Filter Fraction is the proportion of the instantaneous PER used in the current seconds calculation. The remainder (1-Fraction(0.7)) is taken from the previous 250 milli-second calculation. 1.3.6.1.4.1.1316.1.1.1.1.2.12 mdrmteMajorPERExceeded INTEGER read-only This parameter indicates if the major packet (uncorrectable by FEC) error rate has been exceeded based on the defined threshold listed in the mdrmteFAULT mdrmtePerfTrapThreshold group. 1.3.6.1.4.1.1316.1.1.1.1.2.13 mdrmteCriticalPERExceeded INTEGER read-only This parameter indicates if the critical packet (uncorrectable by FEC) error rate has been exceeded based on the defined threshold listed in the mdrmteFAULT mdrmtePerfTrapThreshold group. 1.3.6.1.4.1.1316.1.1.1.1.2.14 mdrmtePrevParamsRestored INTEGER read-only Indicates if “auto recovery” for the Outdoor Unit settings had to be invoked due to an unsuitable choice of frequency or power settings for the RF link. 1.3.6.1.4.1.1316.1.1.1.1.2.15 Deprecated1 INTEGER write-only Deprecated 1.3.6.1.4.1.1316.1.1.1.1.3 mdrmteG826 1.3.6.1.4.1.1316.1.1.1.1.3.1 mdrmteStatus INTEGER read-only Indicates if 'G.826-like' errored, s e v erely errored and unavailable conditions have been monitored on the RF Link. 1.3.6.1.4.1.1316.1.1.1.1.3.2 mdrmteTotalSeconds Counter read-only Indicates the total number of seconds, both available and unavailable. 1.3.6.1.4.1.1316.1.1.1.1.3.3 mdrmteAvailableSeconds Counter read-only A period of unavailable time begins at the onset of ten consecutive SES events. These ten seconds are considered to be part of unavailable time. A new period of available time begins at the onset of ten consecutive nonSES ev ents. These ten seconds are considered to be part of available time. 85 SC5800 User Manual Object ID Group Object Type Access Description 1.3.6.1.4.1.1316.1.1.1.1.3.4 mdrmteUnavailableSeconds Counter read-only A period of unavailable time begins at the onset of ten consecutive SES events. These ten seconds are considered to be part of unavailable time. A new period of available time begins at the onset of ten consecutive nonSES events. These ten seconds are considered to be part of available time. 1.3.6.1.4.1.1316.1.1.1.1.3.5 mdrmteErroredSeconds Counter read-only A one second period with one or more errored packets (uncorrectable packets) or at least one defect. 1.3.6.1.4.1.1316.1.1.1.1.3.6 mdrmteSeverelyErroredSeconds Counter read-only A one-second period which contains > 30% errored blocks or at least one defect. SES is a subset of ES. 1.3.6.1.4.1.1316.1.1.1.1.3.7 mdrmteErroredBlocks Counter read-only A packet that has been identified as containing uncorrectable bits by the FEC circuitry. 1.3.6.1.4.1.1316.1.1.1.1.3.8 mdrmteBackgroundBlockErrors Counter read-only An errored block not occurring as part of a SES. mdrmteErroredSecondsRatio DisplayString read-only The ratio of ES to total seconds in available time during a fixed measurement interval. 1.3.6.1.4.1.1316.1.1.1.1.3.10 mdrmteSeverelyErroredSecondsRatio DisplayString read-only The ratio of SES to total seconds in available time during a fixed measurement interval. 1.3.6.1.4.1.1316.1.1.1.1.3.11 mdrmteBackgroundBlockErrorRatio DisplayString read-only The ratio of Background Block Errors (BBE) to total blocks in the available time during a fixed measurement interval. The count of total blocks excludes all blocks during SESs. 1.3.6.1.4.1.1316.1.1.1.1.3.12 Deprecated2 INTEGER write-only Deprecated 1.3.6.1.4.1.1316.1.1.1.1.3.13 mdrmteCorrectedSymbols INTEGER read-only This parameter lists the number of corrected symbols i.e. those corrected by the FEC. 1.3.6.1.4.1.1316.1.1.1.1.4 Counters† 1.3.6.1.4.1.1316.1.1.1.1.4.1 mdrmteLostEthRxPkts† COUNTER read-only Indicates the total number of times an ethernet packet could not be buffered 1.3.6.1.4.1.1316.1.1.1.1.4.2 MdrmteLostLinkRxPkts† COUNTER read-only Indicates the total number of times a link packet could not be buffered 1.3.6.1.4.1.1316. 1.1.1.1.4.3 MdrmteLostWaySideTxPkts† COUNTER read-only Indicates the total number of times a wayside packet could not be buffered 1.3.6.1.4.1.1316.1.1.1.1.4.4 mdrmteEtherRetries † COUNTER read-only Indicates the total number of (collisions) packets that were retransmitted on Ethernet 1.3.6.1.4.1.1316.1.1.1.1.4.5 mdrmteScc1FullCnt † COUNTER read-only Indicates the total number of times SCC1 was full to capacity 1.3.6.1.4.1.1316.1.1.1.1.3.9 86 SC5800 User Manual Object ID Group Object Type Access Description 1.3.6.1.4.1.1316.1.1.1.1.4.6 mdrmteScc2FullCnt † COUNTER read-only Indicates the total number of times SCC2 was full to capacity 1.3.6.1.4.1.1316.1.1.1.1.4.7 mdrmteScc1UnderrunCnt † COUNTER read-only Indicates the total number of times SCC1 ran out of BDs 1.3.6.1.4.1.1316.1.1.1.1.4.8 mdrmteScc2UnderrunCnt † COU NTER read-only Indicates the total number of times SCC2 ran out of BDs 1.3.6.1.4.1.1316.1.1.1.1.4.9 mdrmteScc2RxBdAbortCnt † COUNTER read-only Indicates the total number of times SCC2 received an aborted frame 1.3.6.1.4.1.1316.1.1.1.1.4.10 mdrmteScc2RxBdNonOctCnt † COUNTER read-only Indicates the total number of times SCC2 received a Non octet aligned frame 1.3.6.1.4.1.1316.1.1.1.1.4.11 mdrmteScc2RxBdCrcCnt † COUNTER read-only Indicates the total number of times SCC2 received 1.3.6.1.4.1. 1316.1.1.1.1.5 mdrmteResetAllPerfData INTEGER write-only Reset all parameters associated with Packet Error and G.826 measurements for the RF Link. 1.3.6.1.4.1.1316.1.1.1.2 mdrmteConfiguration 1.3.6.1.4.1.1316.1.1.1.2.1 MdrmtePayloadConf 1.3.6.1. 4.1.1316.1.1.1.2.1.1 MdrmteDataRate INTEGER read-write Configure the tributary data interface rate - either E1 or T1. 1.3.6.1.4.1.1316.1.1.1.2.1.2 mdrmteLineCodeType INTEGER read-write Defines the line code types for the tributaries, either HDB3 or AMI for E1 tributaries or B8ZS or AMI for T1 tributaries. 1.3.6.1.4.1.1316.1.1.1.2.1.3 mdrmtePcTable SEQUENCE 1.3.6.1.4.1.1316.1.1.1.2.1.3.1 mdrmtePcEntry SYNTAX 1.3.6.1.4.1.1316.1.1.1.2.1.3.1. mdrmtePcIndex INTEGER 1.3.6.1.4.1.1316.1.1.1.2.1.3.1. mdrmtePcLabel DisplayString read-write E1/T1 Payload configuration tributary label. 1.3.6.1.4.1.1316.1.1.1.2.1.3.1. mdrmtePcActive INTEGER read-write Defines whether tributaries are active or inactive. 1.3.6.1.4.1.1316.1.1.1.2.2 mdrmteRFLinkConf 1.3. 6.1.4.1.1316.1.1.1.2.2.1 mdrmteTxPower INTEGER read-write Allows setup of the output power available at the diplexer port of the Outdoor Unit. 1.3.6.1.4.1.1316.1.1.1.2.2.2 mdrmteBandPlan INTEGER read-write The SC5800 Outdoor Units operate in the 5.725 GHz to 5.850 GHz ISM frequency band. The SC5800 has predefined frequency channel plans (termed A, B, C and D). Refer to the User's manual for details on defined frequencies. 1.3.6.1.4.1.1316.1.1.1.2.2.3 mdrmteTxFrequencyPlanD INTEGER read-write Frequency plan D allows independent control of transmit and receive frequencies. This enables a very flexible frequency plan and can be used to overcome interference in the 5.8 GHz ISM band. The frequencies that can be used in the lower or upper sub-bands can be selected in 1 MHz increments. Performance 87 SC5800 User Manual Object ID Group Object Type Access Description degradation can be expected when operating using channel plan D mode and the chosen frequencies are close to the sub-band edges i.e. a choice of one of the high frequencies in the lower sub-band and one of the lower frequencies in the upper sub-band. The allocation of Channel plan D frequencies is Lower Sub-band - 5735-5771 MHz, Upper Sub-band - 58045840 MHz. The user must take note of whether the radio is a high or low band unit before choosing a set of transmit and receive frequencies. Note also that THE TX AND RX FREQUENCIES MUST BE SELECTED BEFORE BAND PLAN D OPTION IS SELECTED VIA THE MIB. 1.3.6.1.4.1.1316.1.1.1.2.2.4 mdrmteRxFrequencyPlanD INTEGER read-write Refer to the mdrmteTxFrequencyPlanD description. 1.3.6.1.4.1.1316.1.1.1.2.2.5 mdrmteTransmitBand INTEGER read-only This value is read from the Outdoor Unit via the Indoor Unit and defines whether it transmits in the Lower Sub-band - 57355771 MHz or Upper Sub-band 5804-5840 MHz. 1.3.6.1.4.1.1316.1.1.1.2.2.6 MdrmteReserved2 INTEGER 1.3.6.1.4.1.1316.1.1.1.2.2.7 mdrmteRegulations INTEGER 1.3.6.1.4.1.1316.1.1.1.2.2.8 mdrmteAutoRecovery INTEGER read-only This feature is used if the user is installing a link from one side and there is no assistance on the opposite side of the link. It mitigates against the link failing and not being able to be reestablished. If “auto recovery” is enabled, the required operational RF parameters are programmed into the Outdoor Units by the local and remote Indoor Units. If communication between the two Indoor Units has not reactivated within 5 seconds, the previous (working) 'default' RF parameters are programmed into the respective Outdoor Units. 1.3.6.1.4.1.1316.1.1.1.2.2.9 mdrmteOURateOverride INTEGER read-write Deprecated 1.3.6.1.4.1.1316.1.1.1.2.2.10 mdrmteOUDataRate INTEGER read-write A settable rate that allows a reduced transfer data rate over the RF Link. 1.3.6.1.4.1.1316.1.1.1.2.2.11 mdrmteTxFrequencyCurrent INTEGER read-only This value [MHz] is read back from the Outdoor Unit and defines the transmit frequency of the Outdoor Unit. 1.3.6.1.4.1.1316.1.1.1.2.2.12 mdrmteRxFrequencyCurrent INTEGER read-only This value [MHz] is read back from the Outdoor Unit and 88 This parameter is read from the Outdoor Unit via the Indoor Unit and defines regulatory compliance of the Outdoor Unit. SC5800 User Manual Object ID Group Object Type Access Description defines the receive frequency of the Outdoor Unit. 1.3.6.1.4.1.1316.1.1.1.2.2.13 mdrmteNonAutoBandPlan INTEGER read-write Same as mdrMTEBandPlan setting in this MIB group except “auto recovery” is not enabled this allows control of the Outdoor Unit frequencies without the “auto recovery” feature attempting to intervene and re-establish setup of an operational RF Link. 1.3.6.1.4.1.1316.1.1.1.2.2.14 mdrmteNonAutoTxFreqPlanD INTEGER read-write Same as mdrTxFrequencyPlanD setting in this MIB group except “auto recovery” is not enabled this allows control of the Outdoor Unit Plan D frequencies without the “auto recovery” feature attempting to intervene and re-establish setup of an operational RF Link. 1.3.6.1.4.1.1316.1.1.1.2.2.15 mdrmteNonAutoRxFreqPlanD INTEGER read-write Same as mdrTxFrequencyPlanD setting in this MIB group except “auto recovery” is not enabled this allows control of the Outdoor Unit Plan D frequencies without the “auto recovery” feature attempting to intervene and re-establish setup of an operational RF Link. 1.3.6.1.4.1.1316.1.1.1.2.2.16 mdrmteNonAutoTxPower INTEGER read-write Same as mdrTxPower setting in this MIB group except “auto recovery” is not enabled - this allows control of the Outdoor Unit power level setting without the “auto recovery” feature attempting to intervene and reestablish setup of an operational RF Link. 1.3.6.1.4.1.1316.1.1.1.2.3 mdrmteServiceChannel 1.3.6.1.4.1.1316.1.1.1.2.3.1 mdrmteScDataRate† 3 INTEGER read-write Bit rate used across the wayside service channel link. 1.3.6.1.4.1.1316.1.1.1.2.3.2 mdrmteScDataBits† 4 INTEGER read-write The data width - can be 7 or 8 bits. 1.3.6.1.4.1.1316.1.1.1.2.3.3 MdrmteScParity INTEGER read-write Serial channel - set to none, odd or even. 1.3.6.1.4.1.1316.1.1.1.2.3.4 MdrmteScStopBits INTEGER read-write The number of stop bits can be set to 1 or 2. 1.3.6.1.4.1.1316.1.1.1.2.3.5 mdrmteScFlowControl INTEGER read-write Either hardware or no f low control is used. 1.3.6.1.4.1.1316.1.1.1.2.3.6 mdrmteScStatusDump INTEGER read-write Allows the wayside service (serial) channel to be used as a diagnostics port [deprecated]. 1.3.6.1.4.1.1316.1.1.1.2.4 MdrmteGeneral 1.3.6.1.4.1.1316.1.1.1.2.4.1 MdrmteStationName DisplayString read-write The station name is stored in the Indoor Unit in non-volatile Fixed at 115.2kbps in Version 1.00 and 2.00, 2.01, 2.02 IU firmware releases. Serial setting – 8 bits, no parity, 1 stop bit 89 SC5800 User Manual Object ID Group Object Type Access Description memory - limited to 14 characters in length. 1.3.6.1.4.1.1316.1.1.1.2.4.2 mdrmteIUSerialNumber DisplayString read-only An electronic serial number is read from the Indoor Unit - this number is unique for each IU and is derived from an IC that is used within the product. 1.3.6.1.4.1.1316.1.1.1.2.4.3 mdrmteIUFirmwareVersion DisplayString read-only The Indoor Unit firmware version is the version of application firmware that loaded into the product's application Flash. 1.3.6.1.4.1.1316.1.1.1.2.4.4 mdrmteIUBootkernelVersion DisplayString read-only The Indoor Unit bootkernel version is the version of boot firmware that loaded into the product's Boot Flash. 1.3.6.1.4.1.1316.1.1.1.2.4.5 mdrmteOUSerialNumber INTEGER read-only The Outdoor Serial Number is programmed into the OU at time of manufacture and is read via the Indoor Unit. 1.3.6.1.4.1.1316.1.1.1.2.4.6 MdrmteOUPICFirmwareVersion DisplayString read-only The Outdoor Unit PIC firmware number is programmed into the OU at time of manufacture and is read via the Indoor Unit. 1.3.6.1.4.1.1316.1.1.1.2.4.7 mdrmteOUPayloadSupport INTEGER 1.3.6.1.4.1.1316.1.1.1.2.4.8 mdrmteDate DisplayString read-write This is a date record that is recovered from the Indoor Unit's Real Time Clock. 1.3.6.1.4.1.1316.1.1.1.2.4.9 mdrmteTime DisplayString read-write This is a time record that is recovered from the Indoor Unit's Real Time Clock. 1.3.6.1.4.1.1316.1.1.1.2. 4.10 mdrmteNOVRAMInit INTEGER read-write If activated, the Nonvolatile memory is initialised to a set of default parameters. 1.3.6.1.4.1.1316.1.1.1.2.4.11 mdrmteFECBypass INTEGER read-write This is primarily a laboratory test entry used to control whether the FEC circuitry within the Indoor Unit is activated. By default the FEC is not bypassed i.e. FEC is active. 1.3.6.1.4.1.1316.1.1.1.2.4.12 mdrmteFECCorrectableSymbols INTEGER read-write This is primarily a laboratory test entry used to control the FEC correction power - 20 parity symbols are appended to the transmit packet - 10 is the maximum number of symbols the FEC circuitry can correct. At a maximum, 20 symbols in error can be detected but only 10 can be corrected - the higher the correction power selected, the greater the improvement in system gain. 1.3.6.1.4.1.1316.1.1.1.2.4.13 mdrmteTribCode DisplayString read-write This is a text entry code (16 characters) used to allow activation of tributaries on the Indoor Units. It is unique to the Indoor Unit based on a hardware-dependent serial number in the IU. 1.3.6.1.4.1.1316.1.1.1.2.4.14 mdrmteIndoorUnitBarCodeNumber† DisplayString read-write This is a text entry code used to 90 Deprecated. SC5800 User Manual Object ID Group Object Type Access Description allow storage of the Indoor Unit's bar code serial number (as seen on the outside of the on the outside of product's housing). 1.3.6.1.4.1.1316.1.1.1.2.4.15 mdrmteIndoorUnitPCBrevision† DisplayString read-write "This is a numeric entry code used to reflect the PCB revision number and modification status." 1.3.6.1.4.1.1316.1.1.1.2.5 mdrmteFirmware 1.3.6.1.4.1.1316.1.1.1.2.5.1 mdrmteFTPServerStatus † INTEGER read-write This allows activation/deactivation of the FTP server that runs in the Indoor Unit and is used to upload new revisions of firmware via a routed IP network. 1.3.6.1.4.1.1316.1.1.1.2.5.2 mdrmteFlashNewFirmware† INTEGER read-write This entry determines the time when the new version of firmware will be activated. 1.3.6.1.4.1.1316.1.1.1.3 mdrmteFault 1.3.6.1.4.1.1316.1.1.1.3.1 mdrmteInfo 1.3.6.1.4.1.1316.1.1.1.3.1.1 mdrmteLEDTable SEQUENCE A group of LEDs on the front panel of the Indoor Unit. 1.3.6.1.4.1.1316.1.1.1.3.1.1.1 mdrmteLEDEntry SYNTAX A LED entry containing objects describing a particular LED. 1.3.6.1.4.1.1316.1.1.1.3.1.1.1. mdrmteLED Index INTEGER A unique value for each LED in the Indoor Unit. Its value ranges from 1 to the number of LEDs on the front panel of the Indoor Unit. 1.3.6.1.4.1.1316.1.1.1.3.1.1.1. mdrmteLEDLabel DisplayString read-only SYSTEM Green OK, Orange (OU/IU Com ms Error), Red (OU/IU Comms Down) PAYLOAD Green OK, Orange (AIS Detected), Red (LOS Detected)RF LINK Green OK, Orange (FEC Correcting Errors), Red (FEC unable to correct errors)In ALL cases flashing red and orange LEDs imply historic alarm conditions (The alarm can be cleared using the front panel button 'position 1': see next paragraph). 1.3.6.1.4.1.1316.1.1.1.3.1.1.1. mdrmteLEDState INTEGER read-only The current state of the LED for a detailed description of functionality, see the mdrmteLEDLabel entry. 1.3.6.1.4.1.1316.1.1.1.3.1.1.1. mdrmteLEDColour INTEGER read-only The current colour of the LED for a detailed description of functionality, see the mdrmteLEDLabel entry. 1.3.6.1.4.1.1316.1.1.1.3.1.2 mdrmteOutdoorUnitComms INTEGER read-only Describes the state of communication with the Outdoor unit in terms of whether it is up or down completely. Alternatively, if there were errors, these are identified as comms errors (based on a CRC check) or content errors (i.e. 91 SC5800 User Manual Object ID Group Object Type Access Description undeclared, unused messages). 1.3.6.1.4.1.1316.1.1.1.3.1.3 mdrmteOutdoorUnitResetType INTEGER read-only This message is read from the Outdoor Unit and identifies the last reason for a reset within the OU. 1.3.6.1.4.1.1316.1.1.1.3.1.4 mdrmteOutdoorUnitLockDetect INTEGER read-only The transmit RF synthesizer, receive RF synthesizer and IF phased locked loop lock detect signals are monitored and reported via this MIB element. 1.3.6.1.4.1.1316.1.1.1.3.2 mdrmteSelfTest 1.3.6.1.4.1.1316.1.1.1.3.2.1 mdrmteFlash INTEGER read-only Identifies pass/fail status of the Indoor Unit's application flash. 1.3.6.1.4.1.1316.1.1.1.3.2.2 mdrmteDRAM INTEGER read-only Identifies pass/fail status of the Indoor Unit's Dynamic RAM. 1.3.6.1.4.1.1316.1.1.1.3.2.3 mdrmteSRAM INTEGER read-only Identifies pass/fail status of the Indoor Unit's Static RAM. 1.3.6.1.4.1.1316.1.1.1.3.2.4 mdrmteLineInterface INTEGER read-only Identifies pass/fail status of the Indoor Unit's Line Interface IC. 1.3.6.1.4.1.1316.1.1.1.3.2.5 mdrmteFPGA INTEGER read-only Identifies pass/fail status of the Indoor Unit's FPGA interface registers to the microprocessor. 1.3.6.1.4.1.1316.1.1.1.3.2.6 mdrmteFEC INTEGER read-only Identifies pass/fail status of the Indoor Unit's FEC IC electrical interface. 1.3.6.1.4.1.1316.1.1.1.3.2.7 mdrmteRealTimeClock INTEGER read-only Identifies pass/fail status of the Indoor Unit's Real Time Clock. 1.3.6.1.4.1.1316.1.1.1.3.2.8 mdrmteIndoorUnitResetType INTEGER read-only This message is read from the Indoor Unit and identifies the last reason for a reset wi thin the IU. 1.3.6.1.4.1.1316.1.1.1.3.2.9 mdrmteLoopbackMode INTEGER read-write Entry defines the loopback mode of a radio station in terms of loopback at either the payload line interface level, baseband processor level in an OU or RF loopback in the OU. 1.3.6.1.4.1.1316.1.1.1.3.2.10 mdrmteLoopbackTimeOut INTEGER read-write This is the number of seconds the loopback will run for until it times out. 1.3.6.1.4.1.1316.1.1.1.3.3 mdrmteTrapManagement 1.3.6.1.4.1.1316.1.1.1.3.3.1 mdrmteTrapFilter INTEGER read-write Alarms within the MDR product are classified as critical, major, minor or informational. The trap filter allows screening of alarms before they are dispatched as traps. 1.3.6.1.4.1.1316.1.1.1.3.3.2 mdrmteNumberTrapManagers INTEGER read-only This entry shows the number of trap managers allowed. 1.3.6.1.4.1.1316.1.1.1.3.3.3 mdrmteTrapManagerTable SEQUENCE 1.3.6.1.4.1.1316.1.1.1.3.3.3.1 mdrmteTrapManagerEntry SYNTAX 1.3.6.1.4.1.1316.1.1.1.3.3.3.1. mdrmteTrapManagerIndex INTEGER 1.3.6.1.4.1.1316.1.1.1.3.3.3.1. mdrmteTrapManagerIP IpAddress read-write This is the IP address of the management station that is set up to detect and act upon 92 SC5800 User Manual Object ID Group Object Type Access Description received traps. 1.3.6.1.4.1.1316.1.1.1.3.3.3.1. mdrmteTrapManagerComm DisplayString read-write This is the “SNMP community name” used for dispatch of traps. 1.3.6.1.4.1.1316.1.1.1.3.3.3.1. mdrmteTrapManagerActive INTEGER read-write Defines whether a particular Trap Manager is active or inactive. 1.3.6.1.4.1.1316.1.1.1.3.4 mdrmtePerfTrapThreshold 1.3.6.1.4.1.1316.1.1.1.3.4.1 mdrmteMinorPERThreshold DisplayString read-write Defines the threshold used as a checking criterion for the Minor PER (Packet Error Rate). 1.3.6.1.4.1.1316.1.1.1.3.4.2 mdrmteMajorPERThreshold DisplayString read-write Defines the threshold used as a checking criterion for the Major PER (Packet Error Rate). 1.3.6.1.4.1.1316.1.1.1.3.4.3 mdrmteCriticalPERThreshold DisplayString read-write Defines the threshold used as a checking criterion for the Critical PER (Packet Error Rate). 1.3.6.1.4.1.1316.1.1.1.3.4.4 mdrmteErrSecRatioThreshold DisplayString read-write Defines the threshold used as a checking criterion for the Errored Second Ratio. 1.3.6.1.4.1.1316.1.1.1.3.4.5 mdrmteSevErrSecRatioThreshold DisplayString read-write Defines the threshold used as a checking criterion for the Severely Errored Second Ratio. 1.3.6.1.4.1.1316.1.1.1.3.4.6 mdrmteBkgrndBlkErrRatioThreshold DisplayString read-write Defines the threshold used as a checking criterion for the Background Block Error Ratio. 1.3.6.1.4.1.1316.1.1.1.3.5 mdrmteEventLogTable SEQUENCE 1.3.6.1.4.1.1316.1.1.1.3.5.1 mdrmteEventLogEntry SYNTAX 1.3.6.1.4.1.1316.1.1.1.3.5.1.1 mdrmteEventIndex INTEGER 1.3.6.1.4.1.1316.1.1.1.3.5.1.2 mdrmteEventDate DisplayString read-only Lists the date on which the event occurred. 1.3.6.1.4.1.1316.1.1.1.3.5.1.3 mdrmteEventTime DisplayString read-only Lists the time when the event occurred. 1.3.6.1.4.1.1316.1.1.1.3.5.1.4 mdrmteEventType INTEGER read-only Lists the type of event informational, minor, major or critical. 1.3.6.1.4.1.1316.1.1.1.3.5.1.5 mdrmteEventDescription DisplayString read-only Textual description of the logged event. 1.3.6.1.4.1.1316.1.1.1.3.6 mdrmteClearEventLog INTEGER write-only This entry is used to clear the Event Log. 1.3.6.1.4.1.1316.1.1.1.3.7 mdrmteResetAllFaults INTEGER write-only 1.3.6.1.4.1.1316.1.1.1.3.8 mdrmteEnableDebug INTEGER read-write This entry is used to enable test and debugging features 1.3.6.1.4.1.1316.1.1.1.3.9 mdrmteErrorWindow INTEGER read-write This entry is used to set the time period in minutes during which errors are counted, but not logged. 1.3.6.1.4.1.1316.1.1.1.4 mdrmteAccess 1.3.6.1.4.1.1316.1.1.1.4.1 mdrmteEthernetIPAddress IpAddress read-write The IP address associated with product's Ethernet port (NOTE : USE A POWER -ON RESET OR RESET BUTTON POSITION ‘3’ TO ALLOW ACCEPTANCE OF THE NEW IP ADDRESS – I.E. 93 SC5800 User Manual Object ID Group Object Type Access Description IT IS UPDATED IN NON VOLATILE MEMORY AND GETS ACCEPTED BY THE INDOOR UNIT’S IP STACK AS A VALID ADDRESS). 1.3.6.1.4.1.1316.1.1.1.4.2 mdrmteEthernetNetMask IpAddress read-write The netmask associated with the Ethernet port. 1.3.6.1.4.1.1316.1.1.1.4.3 mdrmteMaxNumUsers INTEGER read-only If the firmware is complied with the security feature switched on, users can log into an IU. This value is read back from the IU and indicates the maximum number of users that can connect to an Indoor Unit. 1.3.6.1.4.1.1316.1.1.1.4.4 mdrmteMaxNumActiveUsers INTEGER read-only If the firmware is built with the security feature switched on, users can log into an IU. This entry defines the maximum number of active users that can be connected to an Indoor Unit using IP. 1.3.6.1.4.1.1316.1.1.1.4.5 mdrmteNumActiveUsers Gauge read-only If the firmware is built with the security feature switched on, users can log into an IU. This entry defines the number of active users logged into an IU. 1.3.6.1.4.1.1316.1.1.1.4.6 mdrmteUserTable SEQUENCE 1.3.6.1.4.1.1316.1.1.1.4.6.1 mdrmteUserEntry SYNTAX 1.3.6.1.4.1.1316.1.1.1.4.6.1.1 mdrmteUserIndex INTEGER 1.3.6.1.4.1.1316.1.1.1.4.6.1.2 mdrmteUserName DisplayString read-write If the firmware is built with the security feature switched on, users can log into an IU. This entry allows the user to enter a password associated with their sign-on name. 1.3.6.1.4.1.1316.1.1.1.4.6.1.3 mdrmteUserPassword DisplayString write-only If the firmware is built with the security feature switched on, users can log into an IU – this entry allows password entry. 1.3.6.1.4.1.1316.1.1.1.4.6.1.4 mdrmteUserAccessLevel INTEGER read-write If the firmware is built with the security feature switched on, users can log into an IU. The access entries that are used are “read_only” and “administrator”. An administrator can add and delete new users, assign passwords, initialise NOVRAM via SNMP, enter tributary codes, adjust FTP server status, initiate new flash updates after an FTP upload. Read_only prevents the ability of the user to adjust the SETable variables in the MIB. 1.3.6.1.4.1.1316.1.1.1.4.6.1.5 mdrmteUserActive INTEGER read-write Indicates if a user is active or not based on password entry. 1.3.6.1.4.1.1316.1.1.1.4.6.1.6 mdrmteUserAdd INTEGER write-only In security -enabled mode, allows an administrator to add The default build for firmware DOES NOT include a SECURE LOGIN option. 94 SC5800 User Manual Object ID Group Object Type Access Description users. 1.3.6.1.4.1.1316.1.1.1.4.6.1.7 mdrmteUserDelete INTEGER write-only In security -enabled mode, allows an administrator to delete users. 1.3.6.1.4.1.1316.1.1.1.4.7 mdrmteRFLinkIPAddress IpAddress read-write PPP IP address for the RF Link. The user need not adjust this parameter. 1.3.6.1.4.1.1316.1.1.1. 4.8 mdrmteRFLinkNetMask IpAddress read-write PPP IP netmask for the RF Link. The user need not adjust this parameter. 1.3.6.1.4.1.1316.1.1.1.4.9 mdrmteRemoteIPAddress IpAddress read-write Default PPP IP address for the other end of the RF link. 1.3.6.1. 4.1.1316.1.1.1.4.10 MdrmteElementManagerIPAddress IpAddress read-write Default PPP IP address for the the element manager port 10.13.1.1 for a 'local IU' and 10.12.1.1 for a 'remote IU'. 1.3.6.1.4.1.1316.1.1.1.4.11 MdrmteElementManagerNetMask IpAddress read-write IP netmask for the Element Manager PPP port. 1.3.6.1.4.1.1316.1.1.1.4.12 MdrmteIPNegotiable INTEGER read-write Determines if the local PPP IP address is negotiable or not does not need to be adjusted by the user. 1.3.6.1.4.1.1316.1.1.1.4.13 MdrmtePPPisDefaultRoute INTEGER read-write Determines if PPP interface is the default route - does not need to be adjusted by the user. 1.3.6.1.4.1.1316.1.1.1.4.14 MdrmteStaticRouteTable SEQUENCE 1.3.6.1.4.1.1316.1.1.1.4.14.1 MdrmteStaticRouteEntry SY NTAX 1.3.6.1.4.1.1316.1.1.1.4.14.1.1 MdrmteStaticRouteIndex INTEGER 1.3.6.1.4.1.1316.1.1.1.4.14.1.2 MdrmteStaticRouteIPAddressDestination IpAddress read-write Ultimate destination. 1.3.6.1.4.1.1316.1.1.1.4.14.1.3 MdrmteStaticRouteIPAddressMask IpAddress read-write net mask, 255.255.255.255 if destination is host address. 1.3.6.1.4.1.1316.1.1.1.4.14.1.4 mdrmteStaticRouteIPAddressNextHop IpAddress read-write Where to forward. 1.3.6.1.4.1.1316.1.1.1.4.14.1.5 mdrmteStaticRouteInterfaceForNextHop INTEGER read-write Interface (net) for nexthop. 1.3.6.1.4.1.1316.1.1.1.4.15 mdrmteBridgeEnable† INTEGER read-write Determines if the system is to act as a transparent bridge for all Ethernet packets received. 1.3.6.1.4.1.1316.1.1.1.4.16 mdrmteEthernetFullDuplex† INTEGER read-write Determines if the Ethernet interface is full- or half -duplex. 1.3.6.1.4.1.1316.1.1.1.5 mdrmteRelayOutputs 1.3.6.1.4.1.1316.1.1.1.5.1 mdrmteRelay1 1.3.6.1.4.1.1316.1.1.1.5.1.1 mdrmteRelay1Label DisplayString read-write A short, descriptive name indicating the primary function of the relay, most probably in terms of the equipment connected to it. 1.3.6.1.4.1.1316.1.1.1.5.1.2 mdrmteRelay1OpenStateLabel DisplayString read-write A short, descriptive name indicating the primary function of the relay in the open state, most probably in terms of the equipment connected to it. 1.3.6.1.4.1.1316.1.1.1.5.1.3 mdrmteRelay1ClosedStateLabel DisplayString read-write A short, descriptive name indicating the primary function of the relay in the closed state, most probably in terms of the equipment connected to it. 95 SC5800 User Manual Object ID Group Object Type Access Description 1.3.6.1.4.1.1316.1.1.1.5.1.4 mdrmteRelay1Reserved INTEGER 1.3.6.1.4.1.1316.1.1.1.5.1.5 mdrmteRelay1CurrentState INTEGER read-write The current state of the relay. Used to activate/deactivate a relay. 1.3.6.1.4.1.1316.1.1.1.5.1.6 mdrmteRelay1ScriptTable SEQUENCE 1.3.6.1.4.1.1316.1.1.1.5.1.6.1 mdrmteRelay1ScriptEntry SYNTAX 1.3.6.1.4.1.1316.1.1.1.5.1.6.1. mdrmteRelay1ScriptIndex † 6 INTEGER 1.3.6.1.4.1.1316.1.1.1.5.1.6.1. mdrmteRelay1ScriptID INTEGER read-write Defines which of the listed alarms can cause a relay to activate. 1.3.6.1.4.1.1316.1.1.1.5.1.6.1. mdrmteRelay1ScriptActiveLocal INTEGER read-write Defines if the script is active or not for local relay activation. 1.3.6.1.4.1.1316.1.1.1.5.1.6.1. mdrmteRelay1ScriptActiveRemote INTEGER read-write Defines if the script is active or not for remote relay activation. 1.3.6.1.4.1.1316.1.1.1.5.2 mdrmteRelay2 1.3.6.1.4.1.1316.1.1.1.5.2.1 mdrmteRelay2Label DisplayString read-write A short, descriptive name indicating the primary function of the relay, most probably in terms of the equipment connected to it. 1.3.6.1.4.1.1316.1.1.1.5.2.2 mdrmteRelay2OpenStateLabel DisplayString read-write A short, descriptive name indicat ing the primary function of the relay in the open state, most probably in terms of the equipment connected to it. 1.3.6.1.4.1.1316.1.1.1.5.2.3 mdrmteRelay2ClosedStateLabel DisplayString read-write A short, descriptive name indicating the primary function of the relay in the closed state, most probably in terms of the equipment connected to it. 1.3.6.1.4.1.1316.1.1.1.5.2.4 mdrmteRelay2Reserved INTEGER 1.3.6.1.4.1.1316.1.1.1.5.2.5 mdrmteRelay2CurrentState INTEGER read-write The current state of the relay . Used to activate/deactivate a relay. 1.3.6.1.4.1.1316.1.1.1.5.2.6 mdrmteRelay2ScriptTable SEQUENCE 1.3.6.1.4.1.1316.1.1.1.5.2.6.1 mdrmteRelay2ScriptEntry SYNTAX 1.3.6.1.4.1.1316.1.1.1.5.2.6.1. mdrmteRelay2ScriptIndex INTEGER 1.3.6.1.4.1.1316. 1.1.1.5.2.6.1. mdrmteRelay2ScriptID INTEGER read-write Defines which of the listed alarms can cause a relay to activate. 1.3.6.1.4.1.1316.1.1.1.5.2.6.1. mdrmteRelay2ScriptActiveLocal INTEGER read-write Defines if the script is active or not for local relay activation. 1.3.6.1.4.1.1316.1.1.1.5.2.6.1. mdrmteRelay2ScriptActiveRemote INTEGER read-write Defines if the script is active or not for remote relay activation. 1.3.6.1.4.1.1316.1.1.1.6 mdrmteOptoInputs 1.3.6.1.4.1.1316.1.1.1.6.1 mdrmteOptoInput1 1.3.6.1.4.1.1316.1.1.1.6.1.1 mdrmteOptoInput1Label DisplayString read-write A short, descriptive name indicating the primary function of the contact-closure input in Relay scripting is not activated in Versions 1.00 & 2.00, 01, 02 of the IU firmware release. 96 SC5800 User Manual Object ID Group Object Type Access Description the closed state, most probably in terms of the equipment connected to it. 1.3.6.1.4.1.1316.1.1.1.6.1.2 mdrmteOptoInput1State INTEGER read-only Indicates if the opto input contact-closure input is active (on) or not (off). 1.3.6.1.4.1.1316.1.1.1.6.2 mdrmteOptoInput2 1.3.6.1.4.1.1316.1.1.1.6.2.1 mdrmteOptoInput2Label DisplayString read-write A short, descriptive name indicating the primary function of the contact-closure input in the closed state, most probably in terms of the equipment connected to it. 1.3.6.1.4.1.1316.1.1.1.6.2.2 mdrmteOptoInput2State INTEGER read-only Indicates if the opto input contact-closure input is active (on) or not (off). 10.3 The MIB elements – TRAP DESCRIPTIONS MdrmteTrapUndefined: Informational MdrmteTrapPayloadLOS: Critical Indicates a Loss of Signal identified on the INPUT TO a tributary. MdrmteTrapPayloadAIS: Critical Indicates an Alarm Indication Signal ' all 1's ' identified/sensed on the INPUT TO a tributary. MdrmteTrapLinkUnavailable: Critical Indicates, based on G.826 criteria if the RF Link has become unavailable. MdrmteTrapLinkFrameUnlock: Critical Indicates a Frame Unlock condition identified in the Indoor Unit. MdrmteTrapLinkOuSynthUnlock: Critical Indicates if a synthesizer unlock condition was identified in the Outdoor Unit. MdrmteTrapLinkMinorPERExceeded: Minor Indicates the minor packet error rate threshold was exceeded. MdrmteTrapLinkMajorPERExceeded: Major Indicates the major packet error rate threshold was exceeded. MdrmteTrapLinkCriticalPERExceeded: Critical Indicates the critical packet error rate threshold was exceeded. 10 MdrmteTrapLinkESRExceeded: Minor Indicates the Link Errored Second Ratio Threshold limit was exceeded. 11 MdrmteTrapLinkSESRExceeded: Critical Indicates the Link Severely Errored Second Ratio threshold limit was exceeded. 12 MdrmteTrapLinkBBERExceeded: Minor Indicates the Link Background Block Error Rate threshold limit was exceeded. 13 MdrmteTrapFTPUploadDone: Informational Indicates FTP Upload done. 97 SC5800 User Manual 14 MdrmteTrapFlashEraseFail: Informational Indicates failure to erase Application flash. 15 MdrmteTrapFirmwareUpgradePass: Informational Indicates that firmware was uploaded successfully. 16 MdrmteTrapFirmwareUpgradeFail: Informational Indicates that there was a firmware upload failure. 17 MdrmteTrapInterstationCommsTimeOut: Major Indicates an interstation communications timeout. 18 MdrmteTrapInterstationCommsInvalidRespons e: Minor Indicates a communications error on the interstation overhead link. 19 MdrmteTrapOUCommsTimeOut: Major Indicates an Outdoor Unit communications timeout. 20 MdrmteTrapOUCommsInvalidResponse: Minor Indicates an Outdoor Unit communications error an invalid response was received. 21 MdrmteTrapOUCommsTxFail Indicates Outdoor Unit communications transmit failure. 22 MdrmteTrapSSPCRCError: Minor Simple Serial Protocol CRC error identified. 23 MdrmteTrapSSPLengthError: Minor Simple Serial Protocol Length error identified. 24 mdrmteTrapOptoInput1Off: Major Contact closure input off state detected - Opto 1. 25 mdrmteTrapOptoInput1On: Major Contact closure input off state detected - Opto 1. 26 mdrmteTrapOptoInput2Off: Major Contact closure input off state detected - Opto 2. 27 mdrmteTrapOptoInput2On: Major Contact closure input on state detected - Opto 2. 28 mdrmteTrapUserLoginFailed: Informational With security MODE ON - indicates a user attempted to log on and the attempt failed. 29 mdrmteTrapUserLogoutFailed: Informational With security MODE ON - indicates a user attempted to log out and the attempt failed. 30 MdrmteTrapUserAddFailed: Informational With security MODE ON - indicates there was an attempt to add a user, but the attempt failed. 31 mdrmteTrapUserDeleteFailed: Informational With security MODE ON - indicates there was an attempt to remove/delete a user, but the attempt failed. 32 MdrmteTrapUserLogIn: Informational With security MODE ON - indicates a user logged in. 33 MdrmteTrapUserLogOut: Informational With security MODE ON - indicates a user logged out. 34 MdrmteTrapUserAdd: Informational With security MODE ON - indicates a user was added successfully. 35 MdrmteTrapUserDelete: Informational With security MODE ON - indicates a user was deleted successfully. 36 MdrmteTrapOUSetBandPlan: Informational Indicates the Outdoor Unit channel/band plan was changed. 37 mdrm teTrapOUSetTxChannel: Informational Indicates the Outdoor Unit transmit frequency was changed. 38 mdrmteTrapOUSetRxChannel: Informational Indicates the Outdoor Unit receive frequency was changed. 98 SC5800 User Manual 39 MdrmteTrapOUEepromWrite: Minor Indicates there was an attempt to write to the Outdoor Unit EEPROM. 40 mdrmteTrapOUSetTxPower: Informational Indicates there was an attempt to change the transmit power. 41 MdrmteTrapOUSetPNCode – NA Deprecated. 42 MdrmteTrapOUSetAutoRecovery Indicates there was an attempt to change the “auto recovery” setting. 43 MdrmteTrapOUProgramConfig Deprecated. 44 mdrmteTrapOUChangeRFLoopback: Informational Indicates a change the OU RF Loopback setting was implemented. 45 mdrmteTrapOUChangeBBPLoopback: Informational Indicates a change the Baseband Processor Loopback setting was implemented. 46 MdrmteTrapOUWriteBBP: Minor Indicates there was an attempt to write to the Baseband Processor. 47 MdrmteTrapSetDate: Informational Indicates the Indoor Unit date was adjusted. 48 MdrmteTrapSetTime: Informational Indicates the Indoor Unit time was adjusted. 49 MdrmteTrapSynchronizeSwRTC: Informational Indicates the Indoor Unit's time was synchronized with its real-time clock. 50 MdrmteTrapSetRelayLabel A relay label was changed. 51 MdrmteTrapSetRelayOpenStateLabel A relay open-state label was changed. 52 mdrmteTrapSetRelayClosedStateLabel A relay closed-state label was changed. 53 MdrmteTrapSetRelayDefaultState: NA Deprecated. 54 mdrmteTrapSetRelayCurrentState: Informational Relay's current state has changed. 55 mdrmteTrapRelayScriptEnable Relay scripting is enabled. 56 mdrmteTrapRelayScriptDisable Relay scripting is disabled. 57 MdrmteTrapGetEventLog: Informational Indoor Unit's event log is being accessed. 58 MdrmteTrapClearEventLog: Informational Indoor Unit's event log is being cleared. 59 MdrmteTrapSelfTestFailure: Major Indoor Unit's self test failed. 60 MdrmteTrapProcessorReset: Critical There was an Indoor Unit processor reset. 61 MdrmteTrapEtherRx There was an Indoor Unit Receive Ethernet buffer error. 62 MdrmteTrapTest: Informational Test trap. 63 MdrmteTrapGenericText Test trap. 64 mdrmteTrapGenericText_Data Test trap. 65 mdrmteTrapGenericText_DecData Test trap. 66 mdrmteTrapSocket_Error Test trap. 99 SC5800 User Manual 11 APPENDIX C: SETUP OF A PC (WIN 95, 98, NT) TO ALLOW PINGING OF A ‘REMOTE’-CONFIGURED INDOOR UNIT The following diagram shows the default (factory) network IP addresses assigned to the various network ports on the SC5800 System: ROUTING CONFIGURATION 11.1 IP CONFIGURATION OF SC5800 – ROUTING CONFIGURATION SC5800 - ROUTING CONFIGURATION PPP WIRELESS Ethernet 10-BaseT 10.2.1.2 10.10.9.9 10.10.9.10 10.11.1.2 10.13.1.1 10.12.1.1 PPP RS232 PPP RS232 "NEAR" "FAR" Ethernet 10-BaseT Hub Browser/NMS 10.13.1.2 Laptop computer Browser/NMS 10.12.1.2 Laptop computer Browser/NMS 10.2.1.3 Laptop computer To allow pinging of an IU configured as a "remote unit" (i.e., with an IP address of (10.11.1.2) when the PC has a 10.2.1.3 IP address, 10.2.1.2 default gateway and netmask 255.255.0.0, create batch files). Batch file 1 - addroute.bat route add 10.11.0.0 mask 255.255.0.0 10.2.1.3 Batch file 1 adds a route so that the IP stack on the PC "knows" where to send IP packets destined for the net 10.11.0.0 If you want to delete the route, use Batch file 2 - delroute.bat route delete 10.11.0.0 If you want a screen printout of the routes the PC is using, use the command line entry: route print 101 SC5800 User Manual NOTE DO NOT ALLOW AN RF LINK TO ESTABLISH BEFORE DOING A PING on the remote IU (with 10.11.1.2 as an IP address) - if the RF link was established before, use the front panel button "position 3" to reset the IU before attempting to ping. 102 SC5800 User Manual 11.2 IP CONFIGURATION OF SC5800 – BRIDGING AND ROUTING CONFIGURATION The following diagram shows the default (factory) network IP addresses assigned to the various network ports on the SC5800 System: BRIDGING AND ROUTING CONFIGURATION. SC5800 - BRIDGING OR ROUTING DEFAULT CONFIGURATION PPP WIRELESS Ethernet 10-BaseT 10.2.1.2 R 192.168.1.2 192.168.4.2 10.11.1.2 R 192.168.1.3 192.168.4.3 192.168.2.2 192.168.3.3 PPP RS232 PPP RS232 "NEAR" "FAR" Ethernet 10-BaseT Hub Browser/NMS 192.168.2.3 B Laptop computer Browser/NMS 192.168.3.2 B Laptop computer Browser/NMS 10.2.1.3 R 192.168.1.4 B Laptop computer Notes: The netmask for all the 192.168.x.x addresses is 255.255.255.0 The netmask for all the 10.x.x.x addresses is 255.255.0.0 R above refers to “IP routing” B above refers to “Ethernet bridging” 103 SC5800 User Manual 104 SC5800 User Manual 12 APPENDIX D: SC5800 HARDWARE VERSION 2.X DIFFERENCES, COMPATIBILITY SUMMARY Version 1 hardware (Indoor and Outdoor Units) is incompatible with Version 2.x hardware. Note: THIS MANUAL ADDRESS FEATURES SPECIFIC TO VERSION 2 OF THE SPEEDCOM SC5800 PLEASE IGNORE REFERENCES TO OTHER VERSIONS. • The Indoor Unit /Outdoor Unit Twisted Pair Data Interconnection for Version 2 hardware uses 2 twisted pair cables to convey payload and Outdoor Unit control signals. Notes : • Version 2.x firmware (can be uploaded into the Indoor Unit using the NMS’s Maintenance option). • Updated RSSI and Power control functionality have been added to Version 2.x hardware and firmware. Version 2.x firmware has 1. FTP upload functionality (needs to be activated via the MIB) 2. IP Bridging functionality (half and full duplex – selectable via the MIB) 3. Band Plan C 4. Refer to the MIB section of this manual and look for the † symbol to see what MIB-related functionality is in place/activated/planned for Version 2.x + firmware. 5. Functional RF Loopback built-in test feature. Version 2.x NMS has 1. Ability to allow the user to connect to the Indoor Unit using PPP (via a serial cable interface to the IU’s front panel Element Manager RS232 port) or via Ethernet (via the front panel RJ45 connector: 10BaseT). 2. Graphical Spectrum Analyzer display By default, firmware provided for the Indoor Units does not provide a secure login feature (thereby limiting a user’s ability to ‘set’ MIB variables). Suitably adapted firmware versions (dependent on hardware version) need to be requested from the product manufacturer to allow activation of this feature. INDOOR UNIT FIRMWARE UPGRADE NOTICE • • • • Version 2 hardware Indoor Units are identified as have 200+ serial numbers, Outdoor Units have 250+ serial numbers. If upgrading Indoor Units to use V2.02+ IU firmware, upgrade the IU firmware on BOTH sides of the RF Link. Note that firmware upgrades of Version 1 Indoor Unit hardware do not require setting up of the PCB Issue in the MIB (i.e., mdrmteIndoorUnitPCBrevision element.) Upgrade to IU firmware Version 2+ of Version 1 hardware will NOT give improved RSSI functionality. This is only achieved with Version 2 hardware or modified version 1 hardware. As a standard setting for mdrmteIndoorUnitPCBrevision, use MIB selection Issue_2. HOWEVER, if an appropriate Indoor PCB modification (made at the factory) has been made to allow FullDuplex Ethernet operation, the Issue_2_Mod_A selection option in the MIB MUST be used. 105 SC5800 User Manual 13 APPENDIX E: FIXED ANTENNAS The table below identifies the distances where the 1mW/cm2 exposure limits may be exceeded during continuous transmission using the proposed fixed antennas. Manufacturer Type Model Gain Numeric (dBi) gain Channel Peak Power (mW) Calculated Minimum RF Exposure Separation Distance Distance (m) (m) Gabriel Dish SSSP2 52B 29.0 794.3 239.9 1.2 Gabriel Flat panel DFPD1-52 23.9 245.5 239.9 0.7 MTI Flat panel MT-20004 28.0 631.0 239.9 1.1 WARNING: It is the responsibility of the professional installer to ensure that when using the outdoor antenna kits in the United States (or where FCC rules apply), only these antenna configurations shown in the table in section 1.4 are used. The use of any antenna other than those listed is expressly forbidden in accordance to FCC rules CFR47 part 15.204. FCC Radiation Exposure Statement i) This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment when installed as directed. This equipment should be installed and operated with fix -mounted antennas that are installed with a minimum of 2 meters of separation distance between the antenna and all persons body during normal operation and the antennas as shown above. 106
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Create Date : 2001:09:25 16:06:05 Producer : Acrobat Distiller 4.05 for Windows Modify Date : 2001:09:25 16:06:41-04:00 Page Count : 108EXIF Metadata provided by EXIF.tools