Welltronic Technology SIGMA-S400 Sigma Industrial remote controller User Manual Sigma handbook EN V120 FCC

Welltronic Technology CO. LTD. Sigma Industrial remote controller Sigma handbook EN V120 FCC

user manual

Download: Welltronic Technology SIGMA-S400 Sigma Industrial remote controller User Manual Sigma handbook EN V120 FCC
Mirror Download [FCC.gov]Welltronic Technology SIGMA-S400 Sigma Industrial remote controller User Manual Sigma handbook EN V120 FCC
Document ID1907129
Application IDej93bluW2b+66MnsnHB+qA==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize28.55kB (356867 bits)
Date Submitted2013-02-26 00:00:00
Date Available2013-02-26 00:00:00
Creation Date2013-02-23 16:33:53
Producing SoftwareAcrobat Distiller 9.3.3 (Windows)
Document Lastmod2013-02-23 16:33:53
Document TitleSigma handbook_EN V120-FCC.cdr
Document CreatorPScript5.dll Version 5.2
Document Author: David

Sigma
Industrial Remote
Controller
OPRATION GUIDE
Sigma S300
Sigma S302
Sigma S304
Sigma S306
Sigma S400
Sigma S402
Sigma S404
Sigma S406
Sigma S408
Sigma S40xAB
-6 single step buttons
- 6 Buttons, 2 double step buttons + 4 single step buttons
-6 Buttons, 4 double step buttons + 2 single step buttons
- 6 double step buttons
-8 single step buttons
-8 Buttons, 2 double step buttons + 6 single step buttons
-8 Buttons, 4 double step buttons + 4 single step buttons
- 8 Buttons, 6 double step buttons + 2 single step buttons
- 8 double step buttons
-8 Buttons + A/B select function
Σ Sigma makes convenience!!
STOP
Button
Status
indicator
A/B
indicatior
Function
buttons
S30x/S40x
Transmitter
Σ Transmitter specificationFrequence range :
419.2MHz
Transmitting power : < 10mW
0.03mW
Transmitting mode : F1D
Modulation mode : FSK
Security codes : 4.2billion sets
Power source :
2 x AA (LR6) 1.5V alkaline batteries
Power consumption : < 8mA
Opration temperature :
-10°C ~ + 40°C
Enclosure rating: IP60
Size : S30x / S40x
175mm X 70mm X 43mm
S50x / S60x
230mm X 70mm X 43mm
Weight : S30x / S40x 250g
S50x / S60x 310g
(batteries included)
Σ Indicators of transmittor1. Red ON(2sec ) : When STOP Button is pressed down,
the Red LED would light on 2 secs. Now it is in the
STOP Mode.
: After clockwise turning ON the STOP
2. G reen ON
button, press any button(or press the Start-up Button,
it depends on the set up) then the Green LED would
light on. It is in the Start-up Procedure.
3. G reen flash
: During operation, the Green LED would
flash every 2 secs.
: During operation, if the Red LED flashes
4. R ed flash
per sec., it is telling you that the battery power is low.
Please renew 2 x AA alkaline batteries.
5. A/B indicator : In the type S40xAB,S50xAB and
S60xAB, this indicator can show which hoist (A and/or
B) is controlled.
S50x/S60x
Transmitter
Σ Sigma makes convenience!!
Σ Receiver specificationFrequence range :
419.2MHz
Receive Sensitivity : <- 115dBm
Security codes
: 4.2billion sets
Contacts ability
: 5A @ 250VAC
Power source :
AC 110 V
Current rating :
0.5 A
Power consumption : < 8 W
Opration temperature :
-10°C ~ + 40°C
Enclosure rating: IP60
Size : S30x / S40x
220mm X 120mm X75mm
S50x / S60x
240mm X 120mm X90mm
Weight : S30x / S40x 760g
S50x / S60x 950g
(Cable excluded)
S30x/S40x Receiver
S50x/S60x Receiver
Σ Sigma makes convenience!!
Σ Indicators of receiver -
1. PWR (Green ) :
Power indicator. It lightens on when the power is fed in.
2. WORK
Green ON - The Receiver got the Start-up command, and is in Working
Mode, ready for the operation anytime.
Green OFF - The Receiver is still in the Stand-by Mode, and it needs to
receive the Start-up command to operate.
Red Flash - The Receiver is in the Security Code Learning Mode.
3. RF
Red ON
-The RF signal is received.
Red OFF - Non RF signal or low signal.
4 . DATA
Red ON
- The Receiver is waiting for the RF signal.
Red OFF
- The RF signal received and decoded correctly.
Red fast Flash - 5 times/sec , The RF Signal received, but the Security
Code does not match with each other.
Red slow Flash - 1 times/sec , The RF signal received, but it is not Sigma's
Code. The receiver is interfered by other RF signals.
Σ Opration of Sigma-
Start up 1. Power on the receiver and check the PWR LED lightening or not.
2. Turn the STOP Button clockwise and release, the STOP will spring up.
(Please placed batteries into the transmitters at first,if have't placed
batteries)
3. Push any button, or the Start-up Button (if already set by Set-up
program ). Wait till the Transmitter indicator Green LED lightenen,
and the Transmitter will send the Start-up command to the Receiver.
Mean time, if the Receiver got the Start-up command, its WORK LED
will lighten. Release the pressed button(s), and the transmitter's
Green LED will be off.
4. It is ready, and you can operate Sigma now.
Power off 1. Push down the STOP Button anytime, the transmitter will send out the
STOP command to the Receiver. The Receiver will cut down any output,
and the WORK LED should be shut off. The transmitter's RED LED will
still lights on and sending STOP command 2 secs.
2. Now, you may power off the Receiver.
Σ Sigma makes convenience!!
Σ Cautions-
① If you are not a professional, please do not install or uninstall Sigma .
The equipments (or/and Sigma ) would be damaged from your errors.
② The equipments must have the Main Power N.F.B. , Main Power Relay ,
Limits SW. .... , and other safety protecting equipments.
③ To avoid the influence caused by electromagnetic wave, the location of
receiver should be away from motor/converter/welding machine and so
on which may bring it.
④ The Sigma 's receiver should not be mounted inside of any metal box. It
will weaken the strength of the RF signals, and may cause bad receiving
condition for your operation. The receiver should be mounted outside of
any metal box or other safe places that wouldn't cause bad receiving
condition.
⑤ If you will not use Sigma for a long time, about a week or more, the
batteries should be taken off to prevent the batteries electrolyte leakage
to etch the PCB .
⑥ For PERMANENTLY CONNECTED EQUIPMENT, a readily accessible
disconnect device shall be incorporated external to the equipment .
Σ Sigma makes convenience!!
Σ Sigma Functions1. Interlocked Left/ right button is interlocked from each other.
2. Non_Interlocked Left/ right button is not interlocked, and its Two kinds of movements as
below.
①Normal - Push down is ON , and release to be OFF .
②Toggle - Push down would output ON . Release and push down again,
output OFF . (This function could be set by passing EMS.)
3. ON/OFF In this Function, you can set the Left/ Right Button as ON/ OFF function.
The Left Button as O FF , and the Right Button as ON . (This function
could be set by passing EMS.)
4. Special 2nd Step This function only supports the Special Two Step Button, and the
movement is like the below diagram.
Standard Step
Step
Special 2nd Step
Step
Relay 1
Relay 1
Relay 2
Relay 2
5. A/B Selector This Function only supports Button H in S40xAB, Button J in S50xAB
and Button L in S60 x AB, as the A/B Selector to choose Hoist A , Hoist B ,
or A + (plus) B to work together. The moves in turns like this, OFF -> A ->
A+B -> B -> OFF (Repeatedly). At the transmitter, it has the correspond
-ing LED A/ B to indicate which Hoist being controlled.
6. Start Up mode For the safety and convenience, Sigma has 2 kinds of Start-up Mode.
①Any button to start up
- More convenience, but less safety.
②Specified button to start up - In S4xx, press G + H at the same time, in
S5xx, press I + J , while in S6xx, press K + L to start-up Sigma.
This mode could prevent from starting-up by mistake. It provides you
more safety.
Σ Sigma makes convenience!!
7. Working Mode Sigma has  kinds of Working Modes to meet the need of various working
places.
①No Auto Stop - During operation, the Transmitter would not be shut
down automatically. You need to press the STOP
Button for shutting Sigma down.
②Auto Stop
- After starting up, the Transmitter could be automatic
-ally shut down after the set time-out period.
③Continues Link - After starting up, the Transmitter is set to be continu
-ally sending out the RF signals to the Receiver. This
function is for below purposes.
a. Preventing from any interfering RF signal that may
cut-off the regular signal-sending operation.
b. The equipment will be automatically stopped and
cut-off any Output, if the Receiver moves beyond
the effective remote distance.
Notes *1 - In the previous ②Auto Stop m ode and ③Continues Link mode:
The Transmitter consistently consumes power all the time. You need
to additionally set up the Auto Stop time. It can be selected among
3, 1, 2, 5, 10 minute(s) for shutting down the Transmitter. To resume
the operation, you can press the STOP Button at first, then release
it to spring-up---- if the Auto Stop occurred.
*2 - Working Modes are for you to choose among Safety, Power Consum
-ption, and Convenience. The below table is for your reference.
No
Auto Stop
Auto Stop
Continues
Link
Safety
Low
Middle
High
Power
Consumption
Low
Middle
High
Convenience
High
Low
Low
Σ Sigma makes convenience!!
Sigma S300 series installation wiring diagram
FUSE 5A
FUSE 0.5A
A Step 1
B Step 1
A/B Com
18
C Step 1
D Step 1
C/D Com
C/D Step 2
19
E Step 1
F Step 1
E/F Com
E/F Step 2
10
11
12
A Step 2
B Step 2
A/B Com2
13
14
Main
Main
15
16
Power
Sigma S300 series wiring
Σ Sigma makes convenience!!
Sigma S400 series installation wiring diagram
FUSE 5A
FUSE 0.5A
17
A Step 1
B Step 1
A/B Com
A/B Step 2
18
C Step 1
D Step 1
C/D Com
C/D Step 2
19
E Step 1
F Step 1
E/F Com
E/F Step 2
10
11
12
20
G Step 1
H Step 1 (Hoist A)
G/H Com
G/H Step 2 (Hoist B)
13
14
Main
Main
15
16
Power
Sigma S40x series wiring
You are cautioned that changes or modifications not expressly approved by the
party responsible for compliance could void your authority to operate the
equipment.
This device complies with part 15 of the FCC rules. Operation is subject to the
following two conditions
(1) This device may not cause harmful interference and
(2) this device must accept any interference received, including interference
that may cause undesired operation.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : David
Create Date                     : 2013:02:23 16:33:53+08:00
Modify Date                     : 2013:02:23 16:33:53+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Creator                         : David
Title                           : Sigma handbook_EN V120-FCC.cdr
Creator Tool                    : PScript5.dll Version 5.2
Metadata Date                   : 2013:02:23 16:30:42+08:00
Producer                        : Acrobat Distiller 9.3.3 (Windows)
Document ID                     : uuid:c40e3d86-8a78-4ed7-bebc-ca57bebb3739
Instance ID                     : uuid:c40ca34b-1283-42bb-bdf8-74903ea32ea3
Page Count                      : 10
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RCI-SIGMA-S400

Navigation menu