Welltronic Technology SIGMA-S400 Sigma Industrial remote controller User Manual Sigma handbook EN V120 FCC
Welltronic Technology CO. LTD. Sigma Industrial remote controller Sigma handbook EN V120 FCC
user manual
Sigma Industrial Remote Controller OPRATION GUIDE Sigma S300 Sigma S302 Sigma S304 Sigma S306 Sigma S400 Sigma S402 Sigma S404 Sigma S406 Sigma S408 Sigma S40xAB -6 single step buttons - 6 Buttons, 2 double step buttons + 4 single step buttons -6 Buttons, 4 double step buttons + 2 single step buttons - 6 double step buttons -8 single step buttons -8 Buttons, 2 double step buttons + 6 single step buttons -8 Buttons, 4 double step buttons + 4 single step buttons - 8 Buttons, 6 double step buttons + 2 single step buttons - 8 double step buttons -8 Buttons + A/B select function Σ Sigma makes convenience!! STOP Button Status indicator A/B indicatior Function buttons S30x/S40x Transmitter Σ Transmitter specificationFrequence range : 419.2MHz Transmitting power : < 10mW 0.03mW Transmitting mode : F1D Modulation mode : FSK Security codes : 4.2billion sets Power source : 2 x AA (LR6) 1.5V alkaline batteries Power consumption : < 8mA Opration temperature : -10°C ~ + 40°C Enclosure rating: IP60 Size : S30x / S40x 175mm X 70mm X 43mm S50x / S60x 230mm X 70mm X 43mm Weight : S30x / S40x 250g S50x / S60x 310g (batteries included) Σ Indicators of transmittor1. Red ON(2sec ) : When STOP Button is pressed down, the Red LED would light on 2 secs. Now it is in the STOP Mode. : After clockwise turning ON the STOP 2. G reen ON button, press any button(or press the Start-up Button, it depends on the set up) then the Green LED would light on. It is in the Start-up Procedure. 3. G reen flash : During operation, the Green LED would flash every 2 secs. : During operation, if the Red LED flashes 4. R ed flash per sec., it is telling you that the battery power is low. Please renew 2 x AA alkaline batteries. 5. A/B indicator : In the type S40xAB,S50xAB and S60xAB, this indicator can show which hoist (A and/or B) is controlled. S50x/S60x Transmitter Σ Sigma makes convenience!! Σ Receiver specificationFrequence range : 419.2MHz Receive Sensitivity : <- 115dBm Security codes : 4.2billion sets Contacts ability : 5A @ 250VAC Power source : AC 110 V Current rating : 0.5 A Power consumption : < 8 W Opration temperature : -10°C ~ + 40°C Enclosure rating: IP60 Size : S30x / S40x 220mm X 120mm X75mm S50x / S60x 240mm X 120mm X90mm Weight : S30x / S40x 760g S50x / S60x 950g (Cable excluded) S30x/S40x Receiver S50x/S60x Receiver Σ Sigma makes convenience!! Σ Indicators of receiver - 1. PWR (Green ) : Power indicator. It lightens on when the power is fed in. 2. WORK Green ON - The Receiver got the Start-up command, and is in Working Mode, ready for the operation anytime. Green OFF - The Receiver is still in the Stand-by Mode, and it needs to receive the Start-up command to operate. Red Flash - The Receiver is in the Security Code Learning Mode. 3. RF Red ON -The RF signal is received. Red OFF - Non RF signal or low signal. 4 . DATA Red ON - The Receiver is waiting for the RF signal. Red OFF - The RF signal received and decoded correctly. Red fast Flash - 5 times/sec , The RF Signal received, but the Security Code does not match with each other. Red slow Flash - 1 times/sec , The RF signal received, but it is not Sigma's Code. The receiver is interfered by other RF signals. Σ Opration of Sigma- Start up 1. Power on the receiver and check the PWR LED lightening or not. 2. Turn the STOP Button clockwise and release, the STOP will spring up. (Please placed batteries into the transmitters at first,if have't placed batteries) 3. Push any button, or the Start-up Button (if already set by Set-up program ). Wait till the Transmitter indicator Green LED lightenen, and the Transmitter will send the Start-up command to the Receiver. Mean time, if the Receiver got the Start-up command, its WORK LED will lighten. Release the pressed button(s), and the transmitter's Green LED will be off. 4. It is ready, and you can operate Sigma now. Power off 1. Push down the STOP Button anytime, the transmitter will send out the STOP command to the Receiver. The Receiver will cut down any output, and the WORK LED should be shut off. The transmitter's RED LED will still lights on and sending STOP command 2 secs. 2. Now, you may power off the Receiver. Σ Sigma makes convenience!! Σ Cautions- ① If you are not a professional, please do not install or uninstall Sigma . The equipments (or/and Sigma ) would be damaged from your errors. ② The equipments must have the Main Power N.F.B. , Main Power Relay , Limits SW. .... , and other safety protecting equipments. ③ To avoid the influence caused by electromagnetic wave, the location of receiver should be away from motor/converter/welding machine and so on which may bring it. ④ The Sigma 's receiver should not be mounted inside of any metal box. It will weaken the strength of the RF signals, and may cause bad receiving condition for your operation. The receiver should be mounted outside of any metal box or other safe places that wouldn't cause bad receiving condition. ⑤ If you will not use Sigma for a long time, about a week or more, the batteries should be taken off to prevent the batteries electrolyte leakage to etch the PCB . ⑥ For PERMANENTLY CONNECTED EQUIPMENT, a readily accessible disconnect device shall be incorporated external to the equipment . Σ Sigma makes convenience!! Σ Sigma Functions1. Interlocked Left/ right button is interlocked from each other. 2. Non_Interlocked Left/ right button is not interlocked, and its Two kinds of movements as below. ①Normal - Push down is ON , and release to be OFF . ②Toggle - Push down would output ON . Release and push down again, output OFF . (This function could be set by passing EMS.) 3. ON/OFF In this Function, you can set the Left/ Right Button as ON/ OFF function. The Left Button as O FF , and the Right Button as ON . (This function could be set by passing EMS.) 4. Special 2nd Step This function only supports the Special Two Step Button, and the movement is like the below diagram. Standard Step Step Special 2nd Step Step Relay 1 Relay 1 Relay 2 Relay 2 5. A/B Selector This Function only supports Button H in S40xAB, Button J in S50xAB and Button L in S60 x AB, as the A/B Selector to choose Hoist A , Hoist B , or A + (plus) B to work together. The moves in turns like this, OFF -> A -> A+B -> B -> OFF (Repeatedly). At the transmitter, it has the correspond -ing LED A/ B to indicate which Hoist being controlled. 6. Start Up mode For the safety and convenience, Sigma has 2 kinds of Start-up Mode. ①Any button to start up - More convenience, but less safety. ②Specified button to start up - In S4xx, press G + H at the same time, in S5xx, press I + J , while in S6xx, press K + L to start-up Sigma. This mode could prevent from starting-up by mistake. It provides you more safety. Σ Sigma makes convenience!! 7. Working Mode Sigma has kinds of Working Modes to meet the need of various working places. ①No Auto Stop - During operation, the Transmitter would not be shut down automatically. You need to press the STOP Button for shutting Sigma down. ②Auto Stop - After starting up, the Transmitter could be automatic -ally shut down after the set time-out period. ③Continues Link - After starting up, the Transmitter is set to be continu -ally sending out the RF signals to the Receiver. This function is for below purposes. a. Preventing from any interfering RF signal that may cut-off the regular signal-sending operation. b. The equipment will be automatically stopped and cut-off any Output, if the Receiver moves beyond the effective remote distance. Notes *1 - In the previous ②Auto Stop m ode and ③Continues Link mode: The Transmitter consistently consumes power all the time. You need to additionally set up the Auto Stop time. It can be selected among 3, 1, 2, 5, 10 minute(s) for shutting down the Transmitter. To resume the operation, you can press the STOP Button at first, then release it to spring-up---- if the Auto Stop occurred. *2 - Working Modes are for you to choose among Safety, Power Consum -ption, and Convenience. The below table is for your reference. No Auto Stop Auto Stop Continues Link Safety Low Middle High Power Consumption Low Middle High Convenience High Low Low Σ Sigma makes convenience!! Sigma S300 series installation wiring diagram FUSE 5A FUSE 0.5A A Step 1 B Step 1 A/B Com 18 C Step 1 D Step 1 C/D Com C/D Step 2 19 E Step 1 F Step 1 E/F Com E/F Step 2 10 11 12 A Step 2 B Step 2 A/B Com2 13 14 Main Main 15 16 Power Sigma S300 series wiring Σ Sigma makes convenience!! Sigma S400 series installation wiring diagram FUSE 5A FUSE 0.5A 17 A Step 1 B Step 1 A/B Com A/B Step 2 18 C Step 1 D Step 1 C/D Com C/D Step 2 19 E Step 1 F Step 1 E/F Com E/F Step 2 10 11 12 20 G Step 1 H Step 1 (Hoist A) G/H Com G/H Step 2 (Hoist B) 13 14 Main Main 15 16 Power Sigma S40x series wiring You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : David Create Date : 2013:02:23 16:33:53+08:00 Modify Date : 2013:02:23 16:33:53+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Creator : David Title : Sigma handbook_EN V120-FCC.cdr Creator Tool : PScript5.dll Version 5.2 Metadata Date : 2013:02:23 16:30:42+08:00 Producer : Acrobat Distiller 9.3.3 (Windows) Document ID : uuid:c40e3d86-8a78-4ed7-bebc-ca57bebb3739 Instance ID : uuid:c40ca34b-1283-42bb-bdf8-74903ea32ea3 Page Count : 10EXIF Metadata provided by EXIF.tools