Winnix Technologies HYM360 UHF RFID Reader Module User Manual user s manualx
Winnix Technologies Co., Limited UHF RFID Reader Module user s manualx
Manual
UHF RFID Reader Module UHF RFID Reader Module HYM360 Winnix Technologies Co., Limited UHF RFID Reader Module Brief Introduction HYM360 UHF Reader Module complied with EPC C1G2 Protocol, its working frequency is 902.75-927.25MHz, with standard 2dBi antenna, the reading distance can reach 2 meters. With low power consumption, simple power supply and interface circuit, a high-performance and cost-effective RFID system can be established. It is suitable for retail,access control, medical industry, food tracking, anti-counterfeit and so on, especially for small size hand-held UHF RFID reader. Technical Date No. Item Fixed Current Standby Current Frequency Range Default Working Frequency Fixed Power Stepping Interval Label Protocol Starting Time VSWR 10 Max Reading Range Technical Date Unit Remark ≤380 mA 25dBm ≤1 mA EN Pin Low Level 902.75-927.25 Hopping Frequency 25 MHz MHz Frequency Interval 250KHz dBm dBm Max 27dBm 10~25dBm adjustable by soft EPC C1G2 /ISO18000-6C ≤50 ms ≤1.5 2dBi Antenna Characteristics of DC Data Voltage of Power Input High Level Input Low Level Output High Level Output Low Level Enable Current Min Value Typical Value Max Value Unit Remark 3.3 -0.5 2.3 4.2 3.3 3.5 0.5 0.18 3.3 25 uA DC GPIO EN GPIO EN GPIO GPIO VEN≥2V UHF RFID Reader Module Requirement on Antenna Product Features Electrical Properties: It is a general antenna for UHF RFID applications with high gain and low VSWR. Mechanical Properties: The compact and artistic antenna is suitable for all kinds of severe environment for its dual waterproof design with Gasket and silicone and strengthening rib of shell. Performance Specifications Frequency Range:860MHz~960MHz Maximum VSWR: ≤1.3:1 Gain: > 9 dBi H side HPBW: 70° E side HPBW: 70° Polarization: Circular Polarization Relative humidity: 5%~95% Input Impedance: 50 Ω Antenna Connection: N-50KFD (Type N Female) Physical specifications Size: 258mm×258mm×56mm Weight: 0.91kg(without bracket) Material: Engineering Plastic ASA、Aluminums Color: Ivory-white Enclosure Rating: IP67 Operational Temperature: -40℃~+ 85℃ Storage Temperature: -40℃~+ 85℃ Figure 1. The photograph of the antenna UHF RFID Reader Module Installation guide HYN503 antenna can be installed on steal framed structure or bracket by own antenna bracket, and connect with reader with coaxial line. The antenna can be installed horizontally or vertically, it is decided by installation location, the angle can be adjusted after installation according to the real environment. Antenna bracket is an optional accessory, you can choose according to your special requirement. 1. Installation Dimension Figure 2 Dimension of the antenna 2. Installation Steps 2.1 Horizontal Installation Step 1:Use M6 screw, elastic washer and plain washer, to fix the L board on the antenna, please see Figure 3:. 2. L board(Bracket) M6 screw, elastic washer and plain washer Figure 3 The structure for the Step 1 in the first case Step 2:Please use M6 screw, elastic washer and plain washer and “Dog tooth” to fix it on the horizontal and vertical bracket, please see Figure 4. UHF Antenna M6 screw, elastic washer and plain Dog tooth M6 U style screw bolt Figure 4. The structure for the Step 2 in the first case 2.2 Vertical Installation Step 1:Use M6 screw, elastic washer and plain washer, to fix the L board on the antenna, as shown in Figure 5. 2. L board(Bracket) M6 screw, elastic washer and plain washer Figure 5 The structure for the Step 1 in the second case Step 2:Please use M6 screw, elastic washer and plain washer and “Dog tooth” to fix it on the horizontal and vertical bracket, as shown in Figure 6. UHF RFID Reader Module M6 screw, elastic washer and plain washer Dog tooth M6 U style screw bolt Figure 6 The structure for the Step 2 in the second case 6/9 UHF RFID Reader Module Appearance and Structure Drawing 1 Size of Reader Module Interface Definition PIN Signal Name Signal Direction Function/Compatibility Description 1~2 NC 3~6 GND Module Connecting Ground VDD Input Module Supplying power EN Input Module Enabling, GPIO Output 10 GPIO Output 11 UART_RX Input 12 UART_TX Output 13~16 GND Module connecting ground 17 RFOUT Bidirection Module Radio frequency Input and output interface 18~24 GND Module connecting ground NC 7/9 Highly Effective UHF RFID Reader Module Environment Requirement No. Item Working temperature Storage temperature Relative humidity Technical Data Unit -20~+70 ℃ -40~+85 ℃ 10%~90% RH Remark Circuit for Reference Drawing 2 Circuit for reference Warning This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 8/9 UHF RFID Reader Module NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. RF Exposure Statement To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna. If the FCC identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: RVZHYM360” or “Contains FCC ID: RVZHYM360” Please describe the following warning to the manual. This LMA is tested and approved as standalone configuration, additional evaluation may be required for any system integrated this radio module. 9/9
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Joe Create Date : 2015:06:29 10:48:37+08:00 Modify Date : 2015:06:29 10:48:37+08:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Title : Microsoft Word - user's manual.docx Creator : Joe Producer : Acrobat Distiller 11.0 (Windows) Document ID : uuid:8c5a5ef6-263c-4398-9321-4be0f74b9634 Instance ID : uuid:1809f1fd-24cf-4934-a07a-87db8962c972 Page Count : 9EXIF Metadata provided by EXIF.tools