Wistron NeWeb CB1GI210C Integrate with certified module-End product User Manual UMC I210C Rev 3 0 20150824

Wistron NeWeb Corporation Integrate with certified module-End product UMC I210C Rev 3 0 20150824

Contents

UMC-I210C User Manual_Rev 3.0_20150824

   Subject: UMC-I210C User Manual                                                                       REV: 3.0                                                                                                                                                                               PAGE 1 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document          UMC-I210C User Manual                    The document contains proprietary information which is the property of Wistron NeWeb Corporation and is strictly confidential and shall not be disclosed to others in whole or in part, reproduced, copied, or used as basic for design, manufacturing or sale of apparatus without the written permission of Wistron NeWeb Corporation.
   Subject: UMC-I210C User Manual                                                                       REV: 3.0                                                                                                                                                                               PAGE 2 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document Revision History Issue Date  Version  Description 2015/04/16  0.0  Initial Issued 2015/04/30  0.1  Add freq. mapping table and tx output power setting 2015/05/06  0.2  Modify Zigbee Test Center Frequency Setting (i.e. CH. No.) 2015/05/06  1.0  Change document file name to match FCC application form 2015/05/12  2.0  Add LTE antenna gain table 2015/05/26  2.1  Add FCC Warning Message and Note for LTE antenna gain 2015/05/27  2.2  Correct typo 2015/06/08  2.3  Add required description by FCC Part 15.21 2015/08/24  3.0  Add Secure Shell Access Section for PolicyNet v3.1..0-R requirement in section 3.1
   Subject: UMC-I210C User Manual                                                                       REV: 3.0                                                                                                                                                                               PAGE 3 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document Contents 1. Introduction .......................................................................................................................................... 4 2. Test Setup Configuration ..................................................................................................................... 5 2.1 Power Supply and Debug Console Connection ...................................................................... 5 2.2 Antenna Connection ................................................................................................................. 6 2.3 Hardware Component Introduction ....................................................................................... 7 3. Zigbee Test ............................................................................................................................................ 8 3.1 Secure Shell Setup in a Windows Host PC .............................................................................. 8 3.2 Setup socat Server in CB Device ............................................................................................ 10 3.3 Setup socat Client in a Windows PC host ..............................................................................11 3.4 Zigbee Test Command (Refer to Ember Node Test) ............................................................ 12 4. LTE B4/B13 Test ................................................................................................................................. 13 Appendix-I Example of otp-md5 ............................................................................................................... 14
   Subject: UMC-I210C User Manual                                                                       REV: 3.0                                                                                                                                                                               PAGE 4 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 1.       Introduction This User Manual of Victor CB (Communication Board) module is to describe how to use the  following  sections  for  lab  test  by  specific  qualified  engineers  or  technicians. Furthermore,  this  module  is  NOT  intended  for  commercial  use  but  designed  as  part  of Smart  Meter  product  which  mainly  provides  4G  LTE  WAN  access  and/or  Zigbee  HAN access  capabilities.  For  the  procedure  of  CB  installation  into  electric  meter  and  the operation of CB in assembly factory, that information is described in assembly instruction document.     FCC Interference Statement This module complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This module may not cause harmful interference and (2) this module must accept any interference received, including interference that may cause undesired operation.  Radiation Exposure Statement This  module  complies  with  FCC  radiation  exposure  limits  set  forth  for  an  uncontrolled environment.  This  module  should  be  installed  and  operated  with  minimum  distance  of 20cm between radiator and human body.  Any  changes  or  modifications  not  expressly  approved  by  the  party  responsible  for compliance could void the user’s authority to operate the device.
   Subject: UMC-I210C User Manual                                                                       REV: 3.0                                                                                                                                                                               PAGE 5 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 2.       Test Setup Configuration 2.1 Power Supply and Debug Console Connection  Power on Sequence: I. Connect 12-pin-to-Jig-baord cable II. Attach AC-DC Adaptor & USB Debug Port Cable III. Wait for 20 seconds when system ready (See Note 1) IV. Plug-in Console Port cable   [Caution] Improper power on sequence might lead to system boot-up failure!   AC-DC 5V Adaptor Interface Board  DUT (CB) USB Debug Port Console
   Subject: UMC-I210C User Manual                                                                       REV: 3.0                                                                                                                                                                               PAGE 6 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 2.2 Antenna Connection     Connect to LTE primary antenna     Connect to LTE diversity antenna      Connect to Zigbee antenna
   Subject: UMC-I210C User Manual                                                                       REV: 3.0                                                                                                                                                                               PAGE 7 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 2.3 Hardware Component Introduction    AC-DC 5V Adaptor  Interface Board     Victor CB
   Subject: UMC-I210C User Manual                                                                       REV: 3.0                                                                                                                                                                               PAGE 8 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 3.       Zigbee Test 3.1 Secure Shell Setup in a Windows Host PC Install PuTTy for connection to DUT, refer to http://www.putty.org/ Host Name: 192.168.0.1 ; Port: 35001 ; Connection Type: SSH  login as : root ; Response : find otp-md5 9994 (See detail in Appendix-I)
   Subject: UMC-I210C User Manual                                                                       REV: 3.0                                                                                                                                                                               PAGE 9 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document Run the command “newrole -t unconfined_t”     Password: “gridnet”  Run the command “iptables -P INPUT ACCEPT”
   Subject: UMC-I210C User Manual                                                                       REV: 3.0                                                                                                                                                                               PAGE 10 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 3.2 Setup socat Server in CB Device Enter the command “socat TCP-LISTEN:6666,fork /dev/ttyS2,raw,b115200,echo=0“ to complete socat server setup
   Subject: UMC-I210C User Manual                                                                       REV: 3.0                                                                                                                                                                               PAGE 11 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 3.3 Setup socat Client in a Windows PC host   Find socat from http://blog.gentilkiwi.com/downloads/socat-1.7.2.1.zip Unpack socat.7z and then install into a Windows host PC Execute the commands in its corresponding directory D:\Test Tool\socat> socat - tcp4:192.168.0.1:6666 (Enter twice)
   Subject: UMC-I210C User Manual                                                                       REV: 3.0                                                                                                                                                                               PAGE 12 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 3.4 Zigbee Test Command (Refer to Ember Node Test) Freq. channel setting:    setchannel 0x0B Channel Low  : 0x0B -> CH11   Channel Mid  : 0x12 -> CH18   Channel High  : 0x19 -> CH25 Antenna selection:      gpioout a 0 Power mode setting:    settxpowmode 1 1 Power level setting:      setTxPower -3 Single tone output:      txTone Modulation signal output:  txStream
   Subject: UMC-I210C User Manual                                                                       REV: 3.0                                                                                                                                                                               PAGE 13 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 4.     LTE B4/B13 Test It is suggested to use Anritsu MT8820C for RF conductive tests.setc For LTE radiation tests, the LTE antenna gain lists below.  LTE Main Antenna    Band 13 Peak Gain: 2.0 dBi ~ 2.5 dBi    Band 4 Peak Gain: 4.5 dBi ~ 5.0 dBi    LTE Diversity Antenna    Band 13 Peak Gain: 2.0 dBi ~ 2.5 dBi    Band 4 Peak Gain: 2.5 dBi ~ 3.0 dBi
   Subject: UMC-I210C User Manual                                                                       REV: 3.0                                                                                                                                                                               PAGE 14 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document   Appendix-I Example of otp-md5 9996: OWNS ITCH NOB GAUR NEST LYLE 9997: LOUD LUGE HART GOT VEAL CRIB 9998: COLD GYM GYP CHIN HUG SAL For other numbering, please see “root-otp-passwords-3.1.0-R.txt “ for detail.

Navigation menu