Yaesu Musen 20663X20 AMATEUR HANDHELD VHF RADIO - SCANNING RECEIVER User Manual OM
Yaesu Musen Co., Ltd. AMATEUR HANDHELD VHF RADIO - SCANNING RECEIVER OM
Contents
- 1. User Manual 1
- 2. User Manual 2
- 3. User Manual 3
User Manual 3
Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Memory Mode Memory Recall 1. While operating in the VFO mode, press the [ MR] key to enter the Memory mode. 2. Press the [▲] or [▼] key to select the desired memory channel. 3. To return to the VFO mode, press the [#VFO] key. When the transceiver is already set to the Memory mode, an easy way to recall a memory channel is to enter the memory channel number using the numeric keypad. For example: in the Memory Mode to recall memory channel #002, press the [2] key. •To recall Memory Channel #200, enter “200”. To recall Programmable Memory channels “L1/U1” through “L10/U10” enter “201/202” through “210/220”. Changing the memory label (tag) name 1. Press the [ MR] key to recall the memory channel that you wish to label or rename. 2. Press and hold the F key to enter the Set Mode. 3. Press the [▲] or [▼] key to select Set Mode item “20 NAME TAG”. 4. Press the F key to enter (or edit) the channel name tag. “NAME-TAG” message will appear. 5. Press the Alphabet / Numeric keys to enter the characters or symbols for the memory channel “Tag” (label). • To move the cursor to the next character, press the [▲] key. • To correct a mistake, press the [▼] key repeatedly until the cursor returns to the character position. For more details on character/symbol input, see page 38. 6. Press the PTT switch to save the new setting and return to the memory channel. FT-25R/FT-25E Operating Manual 31 Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Memory Mode HOME Channel Memory Recall A “HOME” channel memory is provided for each operating band, to allow quick recall of a favorite operating frequency on each band. The default home channels are below: Default Home Channels Band Frequency 144 MHz Band FM Radio Band 144.000 MHz 95.000 MHz 1. Press the F key, then press the [P1] key. The default home channel, as listed above, is displayed. 2. Press the F key, then press the [P1] key to exit to normal operation. Repeat this process to recall the HOME channel on any operating band. Changing the Home Channel Frequency The home channel frequencies may be changed from the default settings. 1. While operating in the VFO mode, select the desired frequency. 2. Press and hold the [ MR] key. A blank memory channel will be displayed. 3. Press the [P1] key. • “HOME-IN” will be displayed, and then exit to normal operation. • The home channel frequency is changed and overwriting is complete. Memory Offset Tuning Once a particular memory channel is recalled, it is easy to tune off that channel, as though you were in the “VFO” mode. 1. Recall the memory channel. 2. Press the [#VFO] key to activate the “Memory Channel Tuning” feature. The Memory Channel number on the LCD display will be replaced by “tun”. 32 FT-25R/FT-25E Operating Manual Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Memory Mode When an alpha-numeric Tag is shown in place of the memory channel operating frequency display, the display will automatically revert to display the operating frequency along with the “tun” indication. It is not necessary to enter the Menu and change from the alpha-numeric Tag display to the operating frequency display. 3. Press the [▲] or [▼] key to tune to the desired frequency. 4. To return to the original memory frequency, just press the [#VFO] key. The display will revert to a display of the alpha-numeric Tag (if any) that may have originally appeared on the LCD. To store the new frequency while using Memory Offset Tuning, press and hold the [ MR] key (per the normal memory storage procedure). The next-available clear memory location will be displayed. Then press and hold the [ MR] key again to save the new frequency the available memory channel. Deleting Memories All excerpt the Memory Channel “001” and the Home Channels may be easily deleted. Once deleted, the channel data cannot be recovered, so make a note of the information (Memory Channel settings, etc), before deleting the memories. Press and hold the F key to enter the Set Mode. Press the [▲] or [▼] key to select Set Mode item “18 MEM DEL”. Press the F key to enable adjustment of this Item. Press the [▲] or [▼] key to select the memory channel to be “deleted”. 5. Press the F key to delete the selected memory channel. 1. 2. 3. 4. 6. Press the PTT switch to return to normal operation. FT-25R/FT-25E Operating Manual 33 Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Memory Mode Weather Broadcast Channels In the USA, the VHF Weather Broadcast Station Memory Channel Bank has been pre-programmed at the factory for immediate access to NOAA weather information stations. 1. Press and hold the [1] key to recall the Weather Broadcast Memory Bank. 2. Press the [▲] or [▼] key to select the desired Weather Broadcast channel. 3. To scan for additional or stronger CH Frequency CH Frequency Weather stations, just press the PTT 01 162.550 MHz 06 162.500 MHz switch (or press and hold the [▲] or 02 162.400 MHz 07 162.525 MHz 03 162.475 MHz 08 161.650 MHz [▼] key). When the scanner pauses on a sta- 04 162.425 MHz 09 161.775 MHz tion, press the PTT switch once to 05 162.450 MHz 10 163.275 MHz halt the scan, or press it again to restart the scan. 4. To return to normal operation, press the [ MR] key, or press and hold the [1] key again. Severe Weather Alert In the event of extreme weather disturbances, such as severe thunderstorms and hurricanes, the NOAA (National Oceanic and Atmospheric Administration) sends a weather alert accompanied by a 1050 Hz tone and subsequent weather report on one of the NOAA weather channels. 34 FT-25R/FT-25E Operating Manual Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Scanning The FT-25R/E makes available scanning of the stored memory channels, or scanning of the entire operating band, or scanning of a programmable sub band portion. Scanning will halt when signals are encountered, and communication may be initiated on that frequency. Operation is basically the same in each of the above scanning modes. Before beginning, take a moment to select the way the scanning will resume after it halts on a signal. Setting the Scan-Resume Technique Three options for the Scan-Resume mode are available: Display Description In BUSY mode, the scanner will halt on a signal it encounters. Scanning will resume one second after the BUSY other station signal ceases transmitting. In the case (default setting) of constant-carrier signals like Weather Station broadcasts, the scanner will likely remain on this frequency indefinitely. In HOLD mode, the scanner will halt on a signal it encounters. HOLD Scanning will only resume when it is manually re-initiated. In TIME mode, the scanner will halt on a signal it encounters, scanning will resume after five seconds even TIME if a signal is still on the frequency. To cancel scanning, press the the PTT switch, [▲] or [▼] key. Press and hold the F key to enter the Set mode. Press the [▲] or [▼] key to select Set Mode Item “25 RESUME”. Press the F key to enable adjustment of this Set Mode Items. Press the [▲] or [▼] key to select the desired scan-resume mode. 5. Press the PTT switch to save the setting and exit to normal operation. 1. 2. 3. 4. FT-25R/FT-25E Operating Manual 35 Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Scanning VFO Scanning The FT-25R/E provides two VFO scanning functions: “Manual VFO Scanning” and “Programmed Mode (VFO) Scanning.” Manual VFO Scan 1. If necessary, press the [ MR] key to change to the VFO mode. 2. Press and hold the [▲] or [▼] key to initiate upward or downward scanning, respectively. 3. When scanning encounters a signal strong enough to open the squelch, the scanner will halt temporarily; the decimal point of the frequency display will blink to indicate this “Resuming” condition. 4. The scanning will resume according to the Scan-Resume mode selected in the Set Mode Item “25:RESUME”. 5. To cancel scanning, press the PTT switch, [▲] or [▼] key. Programmed Mode (VFO) Scan 1. Press and hold the [#VFO] key. 2. Press the [▲] or [▼] key to select the bandwidth for Programmed Mode (VFO) scanner. Available selections are ±1 MHz, ±2 MHz, ±5 MHz, ALL, PMS-X, and BAND. Display Description BAND The scanner will sweep frequencies on the current op(default setting) erating band. The scanner will sweep ±1 MHz from the operating fre±1MHz quency. ±2MHz ±5MHz ALL PMS-X The scanner will sweep ±2 MHz from the operating frequency. The scanner will sweep ±5 MHz from the operating frequency. The scanner will sweep all frequencies. The scanner will sweep frequencies designated by the currently selected PMS (Programmable Memory Scan) frequency pair. PMS-X will appear in the [#VFO] selections after setting a PMS frequency pair. 36 FT-25R/FT-25E Operating Manual Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Scanning 3. Press the [#VFO] key to save the new setting and return to normal operation. 4. Press the F key, then press the [#VFO] key to start scanning. 5. When scanning encounters a signal strong enough to open the squelch, the scanning will halt temporarily; the decimal point of the frequency display will blink during this “Pause” condition. 6. The scanner will then resume according to the Scan-Resume mode selected in the “RESUME” setting. 7. To cancel scanning, press the PTT switch, [▲] or [▼] key. FT-25R/FT-25E Operating Manual 37 Input Character/Symbol List Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 On a character inputting display such as the memory mode “tag” display, the characters and symbols may be input as below: Key Key Assignment Key Key Assignment 7PQRSpqrs 2ABCabc 8TUVtuv 3DEFdef 9WXYZwxyz 4GHIghi 0 (blank character) 5JKLjkl Û + - , . / : ; @ (blank character) 6MNOmno 38 FT-25R/FT-25E Operating Manual Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Set (Menu) Mode The FT-25R/E Set Mode, already partially described in the previous chapters, may be activated to select or change various transceiver functions. Many of the useful parameter configurations have not been fully detailed in this manual. Refer to the chart below for a list of the Set Mode Items and their various parameters. Press and hold the F key to enter the Set Mode. Press the [▲] or [▼] key to select the Set Mode Item to be adjusted. Press the F key momentarily to enable adjustment of the Set Mode Item. Press the [▲] or [▼] key to adjust or select the parameter to be changed on the Set Mode Item selected in above step. 5. After completing your selection and adjustment, press the PTT switch momentarily to save the new setting and exit to normal operation. 1. 2. 3. 4. Press and hold the F key to move from the lower menu contents to the upper menu contents in the Set Mode. Item (lower menu item) 1 APO 2 ARTS 3 BATTSAVE 4 B-CH.L/O 5 BEEP 6 BELL 7 COMPANDE (COMPANDER) Function Setting of the Automatic Power-Off feature. Selects the Beep option and the Polling Interval during ARTS™ operation. Selects the Receivemode Battery Saver interval (“sleep” ratio) Enables/Disables the Busy Channel LockOut feature. Beep function Enable/ Disable on presssing the keypad, or stopping the receiver scanning. Select the number of CTCSS/DCS/PAGER/ ARTS™ Bell ringer repetitions. Enables/Disables the Voice Compander feature Values OFF / 0.5H to 12.0H (Step 0.5H) BEEP= INRANG / ALWAYS / OFF INTV= 25SEC / 15SEC Default Value OFF BEEP=OFF INTV= 25SEC 200mS / 300mS / 500mS 200mS / 1SEC / 2SEC / OFF OFF / ON OFF KEY+SC / KEY / OFF KEY+SC OFF / 1Time / 3Times/ 5Times / 8Times / CONTINUE OFF OFF / ON OFF FT-25R/FT-25E Operating Manual 39 Set (Menu) Mode Item (lower menu item) 8 CTCSS (CTCSS TONE) 9 CW ID 10 DC VOLT 11 DCS CODE 12 DTMF SET 13 DTMF WRT 14 EDG.BEEP 15 KEY LOCK 16 LAMP 17 LED Function Setting the CTCSS Frequency TX and RX CW Identifier during ARTS™ operation. displays Battery DC Voltage. Setting the DCS CODE TX and RX Selects the MANUAL or AUTO DTMF tones. Setting the DTMF autodialer sending delay time and Speed. Programming to DTMF autodialer. Enables/Disables the Band-edge beeper while selecting the frequency via the [▲] or [▼] key. Keyboard Lock function Selects the LCD/ Keypad Lamp mode. Selects the enable or disable TX/BUSY LED function. Deletes Memory Channel 18 MEM DEL (MEM DELETE) 19 MON/T-CL Selects the MONI (MON/T-CALL) or T.CALL switch function. 20 NAME TAG 40 Renames AlphaNumeric “Tags” for the Memory channels. Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Values 50 CTCSS tones / OFF TX= OFF / ON ID= ------ (6 characters) Default Value TX=100.0Hz RX=100.0Hz TX= OFF ID= blank − − 104 DCS CODEs / OFF TX=023 RX=023 M=MANUAL MODE= MANUAL / D=450mS AUTO DELAY= 50mS / 250mS / S=50mS 450mS / 750mS / 1000mS SPEED= 50mS / 100mS − − BEEP OFF / BEEP ON BEEP OFF KEY / PTT / P+K 5secKey / 10secKey / 30secKey / CONT / OFF TX= ON / OFF BUSY= ON/ OFF KEY 5secKey − TX=ON BUSY=ON − MONITOR / T-CALL1750 MONITOR (*) or T-CALL1750 (*) / T-CALL2100 / T-CALL1000 / T-CALL1450 − − FT-25R/FT-25E Operating Manual Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Set (Menu) Mode Item (lower menu item) 21 PAGER 22 PASSWORD Function Setting the TX CTCSS of 2 tone and the RX CTCSS of 2 tone. Enables/disables the Answer Back function. Enables/disables the Password feature Values Default Value TX: ** ** RX: ** ** ACK : ON / OFF TX=05 47 RX=05 47 ACK=OFF OFF / ON / OFF 23 PRI.RVT Enables/disables the RVT.OFF / RVT. ON Priority Revert feature. 24 REPEATER ARS / MODE / SHIFT function setting ARS=ON ARS= ON / OFF MODE=SIMPLEX / +RTP MODE=SIMPLEX SHIFT=**.**M (*) / -RTP SHIFT= 0.05 MHz - 99.95 MHz (per 50KHz) 25 RESUME Selects the Scan Resume mode. BUSY / HOLD / TIME 26 RF SQL Adjusts the RF Squelch S-1 / S-2 / S-3 / S-4 / S-5 OFF threshold level. / -6 / S-8 / S-FULL / OFF 27 SCN.LAMP Enables/Disables the Scan lamp while paused. Selects the Memory Scan “Skip” channelselection mode. Selects the Tone Encoder and/or Decoder mode. Setting of the frequency steps. 28 SKIP (SKIP SCAN) 29 SQL TYPE 30 STEP 31 TOT Setting of the TOT time. 32 TX PWR Selects TX Power ON / OFF RVT.OFF BUSY ON − − OFF / R-TONE / T-TONE OFF / TSQL / REV TN / DCS / PAGER 5 / 6.25 / 10 / 12.5 / 15 / AUTO 20 / 25 / 50 / 100 kHz, or AUTO 1 min - 30 min (per 1 3min min) or OFF HI(5W) / MID(2.5W) / LOW(0.5W) FT-25R/FT-25E Operating Manual HI(5W) 41 Set (Menu) Mode Item (lower menu item) 33 TX SAVE Function Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Values Default Value Enables/Disables the Transmitter Battery Saver. Enables or disables “VFO Split” operation. SAVE OFF / SAVE ON SAVE OFF VSP.OFF / VSP.ON VSP.OFF 35 VOX Enable / Disable VOX function. VOX OFF / VOX ON VOX OFF 36 WFM.RCV Broadband FM Radio(WFM) function Enables/Disables WFM.ON / WFM.OFF WFM.ON 37 WIDE/NAR Select Wide (±5 kHz) or Narrow (±2.5 kHz) TX Deviation. Enables/Disables the Weather Alert Scan feature. Inversion scrambling (Encryption) WIDE / NARROW WIDE ALT.OFF / ALT. ON ALT.OFF SCRB.OFF/SCRB.ON SCRB.OFF 34 VFO.SPL 38 WX ALERT 39 SCRAMBLE(*) (*) : This function may be displayed, depending on the transceiver version. 42 FT-25R/FT-25E Operating Manual Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Troubleshooting If you suspect a malfunction, check the following items before requesting a repair. The transceiver does not turn on. • Is the battery depleted? • Charge the battery pack after purchase, and when the transceiver has not been used for a long time. • Is the battery pack properly attached? Refer to “Installing the Battery Pack” and securely mount the battery pack. There is no sound. • Is the squelch level (or S meter squelch) set too high? Press the MONI/T.CALL key and verify that you can hear white noise. Adjust the squelch level (or S meter squelch) when receiving a weak signal. • Is the volume low? Rotate the PWR/VOL knob clockwise to increase the volume. • Is the tone squelch or DCS on? When the tone squelch or DCS is on, the sound is not output until the transceiver receives a signal containing the same tone frequency or DCS code set. For more details on the DCS code, refer to the Advance Manual. There is no transmission of radio waves. • Are you pressing the PTT switch properly? • Is the PTT lock on? • Is the Busy TX Block (BCLO function) on? When the Busy TX Block (BCLO function) is on, transmission is inhibited when receiving a signal, even if the PTT switch is pressed. Wait until the signal being received stops and then press the PTT switch. • Is the transmission frequency on a ham radio band? Transmission cannot be performed on the FM Radio Broadcast Band/Information Radio Band. • Is the voltage of the battery pack correct? Check the remaining charge on the battery pack. In addition, using an inadequate power supply where voltage drops during transmission will prevent the FT-25R/E from operating at full capability. The keys or DIAL do not respond. • Is the Keypad Lock or PTT Lock on? FT-25R/FT-25E Operating Manual 43 Troubleshooting Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 The battery pack cannot be charged or battery power depletes immediately after charging. • Is the battery pack being charged with a charger specified by Yaesu? Charge the battery pack using the accessory battery charger (SAD-20B/ C/U/G) or the rapid charge cradle (SBH-22). • Is the battery pack in use exhausted? If the “Charging Error” appears on the desktop charger lamp when charging, there is a chance the battery pack is over discharged. If the error is repeatedly displayed after charging the battery pack several times, the battery pack may have reached its service life or be defective. Battery packs are consumables. Please replace an exhausted battery pack with a new one immediately. Battery packs can be charged and reused up to approximately 300 times. Some specific combinations of signals may cause internal beats (“birdies”) from high frequencies, caused by the internal oscillator. This is not a malfunction. (See the calculation formula below: “n” is for the arbitrary integer). Also, depending on the combination of simultaneously received signals, there may be fluctuations in receive sensitivity. • Receive Frequency = 13 MHz × n multiplicative • Receive Frequency = 19.2 MHz × n multiplicative 44 FT-25R/FT-25E Operating Manual Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Specifications General Frequency Ranges: RX TX FM Broadcast Channel Steps: Frequency Stability: Repeater Shift: Emission Type: Antenna Impedance: Supply Voltage: Current Consumption: (Approx. @7.2V) 136 - 174 MHz 144 - 146 (148) MHz 65-108 MHz 5 / 6.25 / 10 / 12.5 / 15 / 20 / 25 / 50 / 100 kHz ±5 ppm (–10 °C to +60 °C, +14 F to +140F ) ±600 kHz (144 MHz), ±1.6 / 5.0 / 7.6 MHz F2D, F3E 50 Ohms Nominal: 7.4V DC, Negative Ground 215 mA (Receive) 200 mW Output 110 mA (Standby, Saver Off) 30 mA (Standby, Saver On) 4 mA (Auto Power Off) 1.5 A (5 W Tx , 144 MHz) 7.4 V DC Operating Temperature: – 4 °F to +14 °F (– 20 °C to + 60 °C) Case Size: 2.1” (W) x 4.1” (H) x 1.2” (D) (52.5 x 104.5 x 31 mm) (W/O knob and antenna) 9.17 Oz (260 g) with SBR-25LI and antenna Weight: Transmitter RF Power Output: 5.0 W (High) / 2.5 W (Middle) / 0.5 W (Low) (@ 7.4 V with SBR-25LI) Variable Reactance F2D, F3E Modulation Type: Maximum Deviation: ±5.0 kHz (F2D, F3E) At least 60 dB down (@ High and Middle power) Spurious Emission: At least 40 dB down (@ Low power) Microphone Impedance: 2 kOhms FT-25R/FT-25E Operating Manual 45 Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Specifications Receiver Circuit Type: Sensitivity : Selectivity: AF Output: Direct-Conversion 0.2 µV for 12 dB SINAD (140 - 150 MHz, NFM) 0.2 µV for 12 dB SINAD (420 - 470 MHz, NFM) 12 kHz / 35 kHz (–6 dB /–60 dB) 0.8 W @ 16 ohms for 10% THD (@ 7.4 V) (Internal SP Max Power 1 W) 0.8 W @ 16ohms for 10%THD (@ 7.4 V) (EXT SP Jack Max Power 1 W) Specifications are subject to change without notice, and are guaranteed within the 144 MHz amateur band only. Frequency ranges will vary according to transceiver version; check with your dealer. “AUTO” Mode Preset Operating Parameter USA Version Frequency Range (MHz) Mode step 136.000-144.000 144.000-148.000 148.000-156.000 156.000-157.450 157.450-160.600 160.600-160.975 160.975-161.500 161.500-162.900 162.900-174.000 65.000-108.000 (RX only) FM FM FM FM FM FM FM FM FM WFM 12.5 kHz 5k Hz 12.5 kHz 25 kHz 12.5 kHz 25 kHz 12.5 kHz 25 kHz 12.5 kHz 100kHz Asian/European Version Frequency Range (MHz) Mode step 136.000-160.600 160.600-162.025 162.025-174.000 65.000-108.000 (RX only) FM FM FM WFM 12.5 kHz 25 kHz 12.5 kHz 100 kHz 46 FT-25R/FT-25E Operating Manual Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 1. Changes or modifications to this device that are not expressly approved by YAESU MUSEN could void the user’s authorization to operate this device. 2. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference including received, interference that may cause undesired operation. 3. The scanning receiver in this equipment is incapable of tuning, or readily being altered, by the User to operate within the frequency bands allocated to the Domestic public Cellular Telecommunications Service in Part 22. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. DECLARATION BY MANUFACTURER The Scanner receiver is not a digital scanner and is incapable of being converted or modified to a digital scanner receiver by any user. WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE CELLULAR RADIOTELEPHONE SERVICE SIGNALS IS PROHIBITED UNDER FCC RULES AND FEDERAL LAW. FT-25R/FT-25E Operating Manual 47 Note 48 Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 FT-25R/FT-25E Operating Manual Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Note FT-25R/FT-25E Operating Manual 49 Application for FCC / IC FCC ID: K6620663X20, IC: 511B-20663X20 Copyright 2016 YAESU MUSEN CO., LTD. All rights reserved. No portion of this manual may be reproduced without the permission of YAESU MUSEN CO., LTD. YAESU MUSEN CO., LTD. Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku, Tokyo 140-0002 Japan YAESU USA 6125 Phyllis Drive, Cypress, CA 90630, U.S.A. YAESU UK Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO23 0LB, U.K. 1612H-XX Printed in Japan
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : YAESU MUSEN CO., LTD. Create Date : 2016:12:07 09:40:58+09:00 Modify Date : 2016:12:08 09:43:00+09:00 Has XFA : No Language : ja-JP XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2016:12:08 09:43+09:00 Creator Tool : Adobe InDesign CC 2017 (Windows) Instance ID : uuid:3362ba75-a174-40be-8859-f32b0ef760d7 Original Document ID : xmp.did:861FCEFA1159E6119C28902184FFE727 Document ID : xmp.id:5e33098c-341b-724e-b8a2-ec0253a1c185 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:e25c9b63-0924-8f4e-b881-1b946c6631df Derived From Document ID : xmp.did:c9ec6d99-752c-aa4f-b970-9a9e8da1d7cd Derived From Original Document ID: xmp.did:861FCEFA1159E6119C28902184FFE727 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Windows) History Changed : / History When : 2016:12:07 09:40:58+09:00 Format : application/pdf Title : OM Creator : YAESU MUSEN CO., LTD. Producer : Adobe PDF Library 15.0 Trapped : False Page Layout : SinglePage Page Count : 20EXIF Metadata provided by EXIF.tools