Yaesu Musen 20663X20 AMATEUR HANDHELD VHF RADIO - SCANNING RECEIVER User Manual OM

Yaesu Musen Co., Ltd. AMATEUR HANDHELD VHF RADIO - SCANNING RECEIVER OM

Contents

User Manual 3

Download: Yaesu Musen 20663X20 AMATEUR HANDHELD VHF RADIO - SCANNING RECEIVER User Manual OM
Mirror Download [FCC.gov]Yaesu Musen 20663X20 AMATEUR HANDHELD VHF RADIO - SCANNING RECEIVER User Manual OM
Document ID3244131
Application IDwD2YtjzQSs2w37hBLv/6cw==
Document DescriptionUser Manual 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize124.07kB (1550845 bits)
Date Submitted2016-12-30 00:00:00
Date Available2017-06-28 00:00:00
Creation Date2016-12-07 09:40:58
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2016-12-08 09:43:00
Document TitleOM
Document CreatorAdobe InDesign CC 2017 (Windows)
Document Author: YAESU MUSEN CO., LTD.

Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Memory Mode
Memory Recall
1. While operating in the VFO mode, press the [ MR] key to enter the Memory mode.
2. Press the [▲] or [▼] key to select the desired
memory channel.
3. To return to the VFO mode, press the [#VFO]
key.
When the transceiver is already set to the Memory mode, an easy way to
recall a memory channel is to enter the memory channel number using the
numeric keypad.
For example: in the Memory Mode to recall memory channel #002, press
the [2] key.
•To recall Memory Channel #200, enter “200”. To recall Programmable Memory channels “L1/U1” through “L10/U10”
enter “201/202” through “210/220”.
Changing the memory label (tag) name
1. Press the [ MR] key to recall the memory channel that you wish to label
or rename.
2. Press and hold the F key to enter the Set Mode.
3. Press the [▲] or [▼] key to select Set Mode item “20 NAME TAG”.
4. Press the F key to enter (or edit) the channel
name tag.
“NAME-TAG” message will appear.
5. Press the Alphabet / Numeric keys to enter the characters or symbols for
the memory channel “Tag” (label).
• To move the cursor to the next character, press the [▲] key.
• To correct a mistake, press the [▼] key repeatedly until the cursor returns
to the character position.
For more details on character/symbol input, see page 38.
6. Press the PTT switch to save the new setting and return to the memory
channel.
FT-25R/FT-25E Operating Manual
31
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Memory Mode
HOME Channel Memory Recall
A “HOME” channel memory is provided for each operating band, to allow
quick recall of a favorite operating frequency on each band. The default
home channels are below:
Default Home Channels
Band
Frequency
144 MHz Band
FM Radio Band
144.000 MHz
95.000 MHz
1. Press the F key, then press the [P1] key.
The default home channel, as listed above,
is displayed.
2. Press the F key, then press the [P1] key to exit to normal operation.
Repeat this process to recall the HOME channel on any operating band.
Changing the Home Channel Frequency
The home channel frequencies may be changed from the default settings.
1. While operating in the VFO mode, select the desired frequency.
2. Press and hold the [ MR] key.
A blank memory channel will be displayed.
3. Press the [P1] key.
• “HOME-IN” will be displayed, and then exit
to normal operation.
• The home channel frequency is changed and overwriting is complete.
Memory Offset Tuning
Once a particular memory channel is recalled, it is easy to tune off that channel, as though you were in the “VFO” mode.
1. Recall the memory channel.
2. Press the [#VFO] key to activate the “Memory
Channel Tuning” feature.
The Memory Channel number on the LCD
display will be replaced by “tun”.
32
FT-25R/FT-25E Operating Manual
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Memory Mode
When an alpha-numeric Tag is shown in place of the
memory channel operating frequency display, the display
will automatically revert to display the operating frequency along with the “tun” indication. It is not necessary to
enter the Menu and change from the alpha-numeric Tag
display to the operating frequency display.
3. Press the [▲] or [▼] key to tune to the desired frequency.
4. To return to the original memory frequency, just press the [#VFO] key.
The display will revert to a display of the alpha-numeric Tag (if any) that
may have originally appeared on the LCD.
To store the new frequency while using Memory Offset Tuning, press and hold the [ MR] key (per the normal memory
storage procedure). The next-available clear memory location
will be displayed. Then press and hold the [ MR] key again
to save the new frequency the available memory channel.
Deleting Memories
All excerpt the Memory Channel “001” and the Home Channels may be easily deleted.
Once deleted, the channel data cannot be recovered, so
make a note of the information (Memory Channel settings,
etc), before deleting the memories.
Press and hold the F key to enter the Set Mode.
Press the [▲] or [▼] key to select Set Mode item “18 MEM DEL”.
Press the F key to enable adjustment of this Item.
Press the [▲] or [▼] key to select the memory channel to be “deleted”.
5. Press the F key to delete the selected memory channel.
1.
2.
3.
4.
6. Press the PTT switch to return to normal operation.
FT-25R/FT-25E Operating Manual
33
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Memory Mode
Weather Broadcast Channels
In the USA, the VHF Weather Broadcast Station Memory Channel Bank has
been pre-programmed at the factory for immediate access to NOAA weather
information stations.
1. Press and hold the [1] key to recall the
Weather Broadcast Memory Bank.
2. Press the [▲] or [▼] key to select the desired
Weather Broadcast channel.
3. To scan for additional or stronger CH Frequency CH Frequency
Weather stations, just press the PTT 01 162.550 MHz 06 162.500 MHz
switch (or press and hold the [▲] or 02 162.400 MHz 07 162.525 MHz
03 162.475 MHz 08 161.650 MHz
[▼] key).
When the scanner pauses on a sta- 04 162.425 MHz 09 161.775 MHz
tion, press the PTT switch once to 05 162.450 MHz 10 163.275 MHz
halt the scan, or press it again to restart the scan.
4. To return to normal operation, press the [ MR] key, or press and hold the
[1] key again.
Severe Weather Alert
In the event of extreme weather disturbances, such as severe thunderstorms
and hurricanes, the NOAA (National Oceanic and Atmospheric Administration) sends a weather alert accompanied by a 1050 Hz tone and subsequent
weather report on one of the NOAA weather channels.
34
FT-25R/FT-25E Operating Manual
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Scanning
The FT-25R/E makes available scanning of the stored memory channels, or
scanning of the entire operating band, or scanning of a programmable sub
band portion. Scanning will halt when signals are encountered, and communication may be initiated on that frequency.
Operation is basically the same in each of the above scanning modes. Before beginning, take a moment to select the way the scanning will resume
after it halts on a signal.
Setting the Scan-Resume Technique
Three options for the Scan-Resume mode are available:
Display
Description
In BUSY mode, the scanner will halt on a signal it encounters. Scanning will resume one second after the
BUSY
other station signal ceases transmitting. In the case
(default setting) of constant-carrier signals like Weather Station broadcasts, the scanner will likely remain on this frequency
indefinitely.
In HOLD mode, the scanner will halt on a signal it encounters.
HOLD
Scanning will only resume when it is manually re-initiated.
In TIME mode, the scanner will halt on a signal it encounters, scanning will resume after five seconds even
TIME
if a signal is still on the frequency. To cancel scanning,
press the the PTT switch, [▲] or [▼] key.
Press and hold the F key to enter the Set mode.
Press the [▲] or [▼] key to select Set Mode Item “25 RESUME”.
Press the F key to enable adjustment of this Set Mode Items.
Press the [▲] or [▼] key to select the desired
scan-resume mode.
5. Press the PTT switch to save the setting and
exit to normal operation.
1.
2.
3.
4.
FT-25R/FT-25E Operating Manual
35
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Scanning
VFO Scanning
The FT-25R/E provides two VFO scanning functions: “Manual VFO Scanning” and “Programmed Mode (VFO) Scanning.”
Manual VFO Scan
1. If necessary, press the [ MR] key to change to the VFO mode.
2. Press and hold the [▲] or [▼] key to initiate upward or downward scanning,
respectively.
3. When scanning encounters a signal strong enough to open the squelch,
the scanner will halt temporarily; the decimal point of the frequency display
will blink to indicate this “Resuming” condition.
4. The scanning will resume according to the Scan-Resume mode selected in
the Set Mode Item “25:RESUME”.
5. To cancel scanning, press the PTT switch, [▲] or [▼] key.
Programmed Mode (VFO) Scan
1. Press and hold the [#VFO] key.
2. Press the [▲] or [▼] key to select the bandwidth for Programmed Mode (VFO) scanner.
Available selections are ±1 MHz, ±2 MHz, ±5 MHz, ALL, PMS-X, and
BAND.
Display
Description
BAND
The scanner will sweep frequencies on the current op(default setting) erating band.
The scanner will sweep ±1 MHz from the operating fre±1MHz
quency.
±2MHz
±5MHz
ALL
PMS-X
The scanner will sweep ±2 MHz from the operating frequency.
The scanner will sweep ±5 MHz from the operating frequency.
The scanner will sweep all frequencies.
The scanner will sweep frequencies designated by the
currently selected PMS (Programmable Memory Scan)
frequency pair.
PMS-X will appear in the [#VFO] selections after setting a
PMS frequency pair.
36
FT-25R/FT-25E Operating Manual
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Scanning
3. Press the [#VFO] key to save the new setting and return to normal operation.
4. Press the F key, then press the [#VFO] key to start scanning.
5. When scanning encounters a signal strong enough to open the squelch,
the scanning will halt temporarily; the decimal point of the frequency display
will blink during this “Pause” condition.
6. The scanner will then resume according to the Scan-Resume mode selected in the “RESUME” setting.
7. To cancel scanning, press the PTT switch, [▲] or [▼] key.
FT-25R/FT-25E Operating Manual
37
Input Character/Symbol List
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
On a character inputting display such as the memory mode “tag” display, the
characters and symbols may be input as below:
Key
Key Assignment
Key
Key Assignment
7PQRSpqrs
2ABCabc
8TUVtuv
3DEFdef
9WXYZwxyz
4GHIghi
0 (blank character)
5JKLjkl
Û + - , . / : ; @ (blank character)
6MNOmno
38
FT-25R/FT-25E Operating Manual
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Set (Menu) Mode
The FT-25R/E Set Mode, already partially described in the previous chapters, may be activated to select or change various transceiver functions.
Many of the useful parameter configurations have not been fully detailed in
this manual. Refer to the chart below for a list of the Set Mode Items and
their various parameters.
Press and hold the F key to enter the Set Mode.
Press the [▲] or [▼] key to select the Set Mode Item to be adjusted.
Press the F key momentarily to enable adjustment of the Set Mode Item.
Press the [▲] or [▼] key to adjust or select the parameter to be changed
on the Set Mode Item selected in above step.
5. After completing your selection and adjustment, press the PTT switch momentarily to save the new setting and exit to normal operation.
1.
2.
3.
4.
Press and hold the F key to move from the lower menu contents to the upper menu contents in the Set Mode.
Item
(lower menu
item)
1 APO
2 ARTS
3 BATTSAVE
4 B-CH.L/O
5 BEEP
6 BELL
7 COMPANDE
(COMPANDER)
Function
Setting of the Automatic
Power-Off feature.
Selects the Beep
option and the Polling
Interval during ARTS™
operation.
Selects the Receivemode Battery Saver
interval (“sleep” ratio)
Enables/Disables the
Busy Channel LockOut feature.
Beep function Enable/
Disable on presssing
the keypad, or stopping
the receiver scanning.
Select the number of
CTCSS/DCS/PAGER/
ARTS™ Bell ringer
repetitions.
Enables/Disables the
Voice Compander
feature
Values
OFF / 0.5H to 12.0H
(Step 0.5H)
BEEP= INRANG /
ALWAYS / OFF
INTV= 25SEC / 15SEC
Default Value
OFF
BEEP=OFF
INTV= 25SEC
200mS / 300mS / 500mS 200mS
/ 1SEC / 2SEC / OFF
OFF / ON
OFF
KEY+SC / KEY / OFF
KEY+SC
OFF / 1Time / 3Times/
5Times / 8Times /
CONTINUE
OFF
OFF / ON
OFF
FT-25R/FT-25E Operating Manual
39
Set (Menu) Mode
Item
(lower menu
item)
8 CTCSS
(CTCSS TONE)
9 CW ID
10 DC VOLT
11 DCS CODE
12 DTMF SET
13 DTMF WRT
14 EDG.BEEP
15 KEY LOCK
16 LAMP
17 LED
Function
Setting the CTCSS
Frequency TX and RX
CW Identifier during
ARTS™ operation.
displays Battery DC
Voltage.
Setting the DCS CODE
TX and RX
Selects the MANUAL
or AUTO DTMF tones.
Setting the DTMF
autodialer sending
delay time and Speed.
Programming to DTMF
autodialer.
Enables/Disables the
Band-edge beeper
while selecting the
frequency via the [▲]
or [▼] key.
Keyboard Lock function
Selects the LCD/
Keypad Lamp mode.
Selects the enable or
disable TX/BUSY LED
function.
Deletes Memory
Channel
18 MEM DEL
(MEM
DELETE)
19 MON/T-CL
Selects the MONI
(MON/T-CALL) or T.CALL switch
function.
20 NAME TAG
40
Renames AlphaNumeric “Tags” for the
Memory channels.
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Values
50 CTCSS tones / OFF
TX= OFF / ON
ID= ------ (6 characters)
Default Value
TX=100.0Hz
RX=100.0Hz
TX= OFF
ID= blank
−
−
104 DCS CODEs / OFF
TX=023
RX=023
M=MANUAL
MODE= MANUAL /
D=450mS
AUTO
DELAY= 50mS / 250mS / S=50mS
450mS / 750mS
/ 1000mS
SPEED= 50mS / 100mS
−
−
BEEP OFF / BEEP ON
BEEP OFF
KEY / PTT / P+K
5secKey / 10secKey /
30secKey / CONT / OFF
TX= ON / OFF
BUSY= ON/ OFF
KEY
5secKey
−
TX=ON
BUSY=ON
−
MONITOR / T-CALL1750 MONITOR (*) or
T-CALL1750 (*)
/ T-CALL2100 /
T-CALL1000 /
T-CALL1450
−
−
FT-25R/FT-25E Operating Manual
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Set (Menu) Mode
Item
(lower menu
item)
21 PAGER
22 PASSWORD
Function
Setting the TX CTCSS
of 2 tone and the RX
CTCSS of 2 tone.
Enables/disables the
Answer Back function.
Enables/disables the
Password feature
Values
Default Value
TX: ** **
RX: ** **
ACK : ON / OFF
TX=05 47
RX=05 47
ACK=OFF
OFF / ON /
OFF
23 PRI.RVT
Enables/disables the
RVT.OFF / RVT. ON
Priority Revert feature.
24 REPEATER
ARS / MODE / SHIFT
function setting
ARS=ON
ARS= ON / OFF
MODE=SIMPLEX / +RTP MODE=SIMPLEX
SHIFT=**.**M (*)
/ -RTP
SHIFT= 0.05 MHz - 99.95
MHz (per 50KHz)
25 RESUME
Selects the Scan
Resume mode.
BUSY / HOLD / TIME
26 RF SQL
Adjusts the RF Squelch S-1 / S-2 / S-3 / S-4 / S-5 OFF
threshold level.
/ -6 / S-8 / S-FULL / OFF
27 SCN.LAMP
Enables/Disables
the Scan lamp while
paused.
Selects the Memory
Scan “Skip” channelselection mode.
Selects the Tone
Encoder and/or
Decoder mode.
Setting of the frequency
steps.
28 SKIP
(SKIP SCAN)
29 SQL TYPE
30 STEP
31 TOT
Setting of the TOT
time.
32 TX PWR
Selects TX Power
ON / OFF
RVT.OFF
BUSY
ON
−
−
OFF / R-TONE / T-TONE OFF
/ TSQL / REV TN / DCS /
PAGER
5 / 6.25 / 10 / 12.5 / 15 / AUTO
20 / 25 / 50 / 100 kHz, or
AUTO
1 min - 30 min (per 1
3min
min) or OFF
HI(5W) / MID(2.5W) /
LOW(0.5W)
FT-25R/FT-25E Operating Manual
HI(5W)
41
Set (Menu) Mode
Item
(lower menu
item)
33 TX SAVE
Function
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Values
Default Value
Enables/Disables the
Transmitter Battery
Saver.
Enables or disables
“VFO Split” operation.
SAVE OFF / SAVE ON
SAVE OFF
VSP.OFF / VSP.ON
VSP.OFF
35 VOX
Enable / Disable VOX
function.
VOX OFF / VOX ON
VOX OFF
36 WFM.RCV
Broadband FM
Radio(WFM) function
Enables/Disables
WFM.ON / WFM.OFF
WFM.ON
37 WIDE/NAR
Select Wide (±5 kHz)
or Narrow (±2.5 kHz)
TX Deviation.
Enables/Disables the
Weather Alert Scan
feature.
Inversion scrambling
(Encryption)
WIDE / NARROW
WIDE
ALT.OFF / ALT. ON
ALT.OFF
SCRB.OFF/SCRB.ON
SCRB.OFF
34 VFO.SPL
38 WX ALERT
39
SCRAMBLE(*)
(*) : This function may be displayed, depending on the transceiver version.
42
FT-25R/FT-25E Operating Manual
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Troubleshooting
If you suspect a malfunction, check the following items before requesting a
repair.
The transceiver does not turn on.
• Is the battery depleted?
•	Charge the battery pack after purchase, and when the transceiver has not
been used for a long time.
• Is the battery pack properly attached?
Refer to “Installing the Battery Pack” and securely mount the battery pack.
There is no sound.
• Is the squelch level (or S meter squelch) set too high?
Press the MONI/T.CALL key and verify that you can hear white noise.
	Adjust the squelch level (or S meter squelch) when receiving a weak signal.
• Is the volume low?
Rotate the PWR/VOL knob clockwise to increase the volume.
• Is the tone squelch or DCS on?
	When the tone squelch or DCS is on, the sound is not output until the
transceiver receives a signal containing the same tone frequency or DCS
code set.
For more details on the DCS code, refer to the Advance Manual.
There is no transmission of radio waves.
• Are you pressing the PTT switch properly?
• Is the PTT lock on?
• Is the Busy TX Block (BCLO function) on?
	When the Busy TX Block (BCLO function) is on, transmission is inhibited
when receiving a signal, even if the PTT switch is pressed. Wait until the
signal being received stops and then press the PTT switch.
• Is the transmission frequency on a ham radio band?
	Transmission cannot be performed on the FM Radio Broadcast Band/Information Radio Band.
• Is the voltage of the battery pack correct?
Check the remaining charge on the battery pack.
	In addition, using an inadequate power supply where voltage drops during
transmission will prevent the FT-25R/E from operating at full capability.
The keys or DIAL do not respond.
• Is the Keypad Lock or PTT Lock on?
FT-25R/FT-25E Operating Manual
43
Troubleshooting
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
The battery pack cannot be charged or battery power
depletes immediately after charging.
• Is the battery pack being charged with a charger specified by Yaesu?
	Charge the battery pack using the accessory battery charger (SAD-20B/
C/U/G) or the rapid charge cradle (SBH-22).
• Is the battery pack in use exhausted?
	If the “Charging Error” appears on the desktop charger lamp when
charging, there is a chance the battery pack is over discharged. If the error is repeatedly displayed after charging the battery pack several times,
the battery pack may have reached its service life or be defective. Battery
packs are consumables. Please replace an exhausted battery pack with
a new one immediately. Battery packs can be charged and reused up to
approximately 300 times.
Some specific combinations of signals may cause internal beats (“birdies”)
from
high frequencies, caused by the internal oscillator. This is not a malfunction.
(See the calculation formula below: “n” is for the arbitrary integer). Also, depending on the combination of simultaneously received signals, there may
be fluctuations in receive sensitivity.
• Receive Frequency = 13 MHz × n multiplicative
• Receive Frequency = 19.2 MHz × n multiplicative
44
FT-25R/FT-25E Operating Manual
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Specifications
General
Frequency Ranges: RX
TX
FM Broadcast
Channel Steps:
Frequency Stability:
Repeater Shift:
Emission Type:
Antenna Impedance:
Supply Voltage:
Current Consumption:
(Approx. @7.2V)
136 - 174 MHz
144 - 146 (148) MHz
65-108 MHz
5 / 6.25 / 10 / 12.5 / 15 / 20 / 25 / 50 / 100 kHz
±5 ppm (–10 °C to +60 °C, +14 F to +140F )
±600 kHz (144 MHz), ±1.6 / 5.0 / 7.6 MHz
F2D, F3E
50 Ohms
Nominal: 7.4V DC, Negative Ground
215 mA (Receive) 200 mW Output
110 mA (Standby, Saver Off)
30 mA (Standby, Saver On)
4 mA (Auto Power Off)
1.5 A (5 W Tx , 144 MHz) 7.4 V DC
Operating Temperature: – 4 °F to +14 °F (– 20 °C to + 60 °C)
Case Size:
2.1” (W) x 4.1” (H) x 1.2” (D) (52.5 x 104.5 x 31 mm)
(W/O knob and antenna)
9.17 Oz (260 g) with SBR-25LI and antenna
Weight:
Transmitter
RF Power Output:
5.0 W (High) / 2.5 W (Middle) / 0.5 W (Low)
(@ 7.4 V with SBR-25LI)
Variable Reactance F2D, F3E
Modulation Type:
Maximum Deviation:
±5.0 kHz (F2D, F3E)
At least 60 dB down (@ High and Middle power)
Spurious Emission:
At least 40 dB down (@ Low power)
Microphone Impedance: 2 kOhms
FT-25R/FT-25E Operating Manual
45
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Specifications
Receiver
Circuit Type:
Sensitivity :
Selectivity:
AF Output:
Direct-Conversion
0.2 µV for 12 dB SINAD (140 - 150 MHz, NFM)
0.2 µV for 12 dB SINAD (420 - 470 MHz, NFM)
12 kHz / 35 kHz (–6 dB /–60 dB)
0.8 W @ 16 ohms for 10% THD (@ 7.4 V)
(Internal SP Max Power 1 W)
0.8 W @ 16ohms for 10%THD (@ 7.4 V)
(EXT SP Jack Max Power 1 W)
Specifications are subject to change without notice, and are guaranteed within the 144 MHz amateur band only. Frequency ranges will vary according to
transceiver version; check with your dealer.
“AUTO” Mode Preset Operating Parameter
USA Version
Frequency Range (MHz)
Mode
step
136.000-144.000
144.000-148.000
148.000-156.000
156.000-157.450
157.450-160.600
160.600-160.975
160.975-161.500
161.500-162.900
162.900-174.000
65.000-108.000 (RX only)
FM
FM
FM
FM
FM
FM
FM
FM
FM
WFM
12.5 kHz
5k Hz
12.5 kHz
25 kHz
12.5 kHz
25 kHz
12.5 kHz
25 kHz
12.5 kHz
100kHz
Asian/European Version
Frequency Range (MHz)
Mode
step
136.000-160.600
160.600-162.025
162.025-174.000
65.000-108.000 (RX only)
FM
FM
FM
WFM
12.5 kHz
25 kHz
12.5 kHz
100 kHz
46
FT-25R/FT-25E Operating Manual
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
1. Changes or modifications to this device that are not expressly
approved by YAESU MUSEN could void the user’s authorization
to operate this device.
2. This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept
any interference including received, interference that may cause
undesired operation.
3. The scanning receiver in this equipment is incapable of tuning,
or readily being altered, by the User to operate within the
frequency bands allocated to the Domestic public Cellular
Telecommunications Service in Part 22.
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes : (1) l’appareil ne
doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage
est susceptible d’en compromettre le fonctionnement.
DECLARATION BY MANUFACTURER
The Scanner receiver is not a digital scanner and is incapable of
being converted or modified to a digital scanner receiver by any
user.
WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE
CELLULAR RADIOTELEPHONE SERVICE SIGNALS IS
PROHIBITED UNDER FCC RULES AND FEDERAL LAW.
FT-25R/FT-25E Operating Manual
47
Note
48
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
FT-25R/FT-25E Operating Manual
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Note
FT-25R/FT-25E Operating Manual
49
Application for FCC / IC
FCC ID: K6620663X20, IC: 511B-20663X20
Copyright 2016
YAESU MUSEN CO., LTD.
All rights reserved.
No portion of this manual
may be reproduced
without the permission of
YAESU MUSEN CO., LTD.
YAESU MUSEN CO., LTD.
Tennozu Parkside Building
2-5-8 Higashi-Shinagawa, Shinagawa-ku, Tokyo 140-0002 Japan
YAESU USA
6125 Phyllis Drive, Cypress, CA 90630, U.S.A.
YAESU UK
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
1612H-XX
Printed in Japan

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : YAESU MUSEN CO., LTD.
Create Date                     : 2016:12:07 09:40:58+09:00
Modify Date                     : 2016:12:08 09:43:00+09:00
Has XFA                         : No
Language                        : ja-JP
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2016:12:08 09:43+09:00
Creator Tool                    : Adobe InDesign CC 2017 (Windows)
Instance ID                     : uuid:3362ba75-a174-40be-8859-f32b0ef760d7
Original Document ID            : xmp.did:861FCEFA1159E6119C28902184FFE727
Document ID                     : xmp.id:5e33098c-341b-724e-b8a2-ec0253a1c185
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:e25c9b63-0924-8f4e-b881-1b946c6631df
Derived From Document ID        : xmp.did:c9ec6d99-752c-aa4f-b970-9a9e8da1d7cd
Derived From Original Document ID: xmp.did:861FCEFA1159E6119C28902184FFE727
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Windows)
History Changed                 : /
History When                    : 2016:12:07 09:40:58+09:00
Format                          : application/pdf
Title                           : OM
Creator                         : YAESU MUSEN CO., LTD.
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Layout                     : SinglePage
Page Count                      : 20
EXIF Metadata provided by EXIF.tools
FCC ID Filing: K6620663X20

Navigation menu