Yaesu Musen 50023X20 AIR BAND HT RADIO User Manual 2

Yaesu Musen Co., Ltd. AIR BAND HT RADIO 2

Contents

User Manual 2

Download: Yaesu Musen 50023X20 AIR BAND HT RADIO User Manual 2
Mirror Download [FCC.gov]Yaesu Musen 50023X20 AIR BAND HT RADIO User Manual 2
Document ID3372080
Application IDkPdNNZsG+rNifh81OjpKAw==
Document DescriptionUser Manual 2
Short Term ConfidentialYes
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize211.2kB (2640053 bits)
Date Submitted2017-04-26 00:00:00
Date Available2017-10-23 00:00:00
Creation Date2017-04-20 16:38:30
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2017-04-20 16:38:36
Document TitleUser Manual 2
Document CreatorAdobe InDesign CS6 (Windows)

Advanced Operation
Function Modes
The [FUNC] key provides up to 6 quick access function assignments.
1. Press the [FUNC] key.
2. Select the desired function
by pressing the [◄] or [►]
key, and then press the
[ENT] key.
DUAL WATCH
Activates the dual watch function (see page
21).
RX NOISE
Setting the level of RX noise canceling (see
page 22).
DIM/DISP
Enable/Disable the display lamp illumination.
SCAN MEM
The current channel is marked to be
scanned (see page 33).
SCAN
Activates the scan function (see
page 32).
28
KEY BEEP
Setting the loudness of key beeps (see
page 37).
MEMO
Enters Memory writing mode (see page
30).
LIGHT
The white LED may be used as a flashlight.
To program the function assigned to the function key:
1. [MENU] à “SETUP” à “CONFIG” à “KEY ASSIGNMENT”.
2. Select the assign number (“1” to “6”) to which you
want to assign a function by pressing the [▲] or [▼]
key, and then press the [ENT] key.
3. Select the function you want to assign to the Function Screen by pressing the [◄] or [►] key, and
then press the [ENT] key.
Tip: The default setting:
1: DUAL WATCH
4: RX NOISE
2: SCAN
5: DIM/DISP
3: SCAN MEM
6: LIGHT
4. Press the PTT switch to return to normal operation.
FTA-250L Operating Manual
Memory Operation
The FTA-250L is capable of programming up to 250
user-programmable memory channels with channel
frequency, channel tag (name) up to 7 characters,
and flag (marking for search refinement).
The stored channels can be assigned to ALL or Group
Memory (GP1-GP9), which can be named with up to
8 characters.
The FTA-250L’s memory system allows you to store,
label, and recall channel frequencies you may use
frequently.
Recalling the Memories
1. Press the [ MENU ] key
to display the MENU
screen.
2. Select “MEMORY” on
the screen by pressing
the [◄] or [►] key, and
then press the [ ENT ]
key.
FTA-250L Operating Manual
3. Select a group that the
desired channel belongs
to, by pressing the [ ▲ ]
or [ ▼ ] key followed by
the [ENT] key.
 The memory channels belong to either of the
following groups.
ALL :
Group including all the memory
channels
GP1 to GP9 : Groups of memory channels that
you can set “GP1” to “GP9” when
storing.
The frequency and tag name of the channel listed
will be displayed along with the group name selected in step 3.
4. Select a memory channel
with the [▲] or [▼] key.
5. To exit the Memory mode, press the [MENU] key,
select the mode other than “MEMORY” on the
screen by pressing the [◄] or [►] key, and then
press the [ENT] key.
29
Memory Operation
Instant Storage
1. Select a desired frequency.
2. Press and hold the [ENT]
key.
 The “ADD” selection appears on the
d i s p l a y, w i t h t h e
frequency, channel
name (tag), group
name, and scan
memory already filled
in.
3. Press the [▲] or [▼] key to select the item, then
press the [ENT] key.
4. Input letters and/or numbers with the keypad, or
select a setting with the [▲], [▼], [◄], or [►] key,
then press the [ENT] key.
5. Select “SAVE MEMORY”
by pressing the [▼] key,
and then press the [ENT]
key to store the frequency into the memory.
Note: You cannot store weather channels to the
memory by pressing the [ENT] key during the
WX mode.
30
Maintenance of the Memory
Adding new memory channels, editing the stored
information, and deleting the stored addresses are allowed through the SETUP mode.
Adding entries
1. [ MENU ] à “SETUP” à “MEMORY BOOK” à
“ADD”.
2. Select the item, input letters and/or numbers, select a setting, and store the changes in the same
way as the instant storage described previously.
Notes:  You cannot skip the input of “NAME” (channel tag).
 You must input of “FREQ” (channel frequency).
Editing the information
1. [ MENU ] à “SETUP” à “MEMORY BOOK” à
“EDIT”.
2. Press the [▲] or [▼] key to select the group including the entry you want to edit, then press the
[ENT] key.
3. Press the [▲] or [▼] key to select the entry you
want to edit, then press the [ENT] key.
4. Select the item, input letters and/or numbers, select a setting, and then store the changes in the
same way as the instant storage described previously.
FTA-250L Operating Manual
Memory Operation
Deleting the memory
1. [MENU] à “SETUP” à “MEMORY BOOK” à “DELETE”.
2. Press the [▲] or [▼] key to select the group including the entry you want to delete, then press
the [ENT] key.
3. Press the [▲] or [▼] key to select the entry you
want to delete, then press the [ENT] key.
4. S e l e c t “ O K ? ” o n t h e
screen by pressing the [◄]
or [►] key, and then press
the [ENT] key.
5. Press the PTT switch to return to normal operation.
FTA-250L Operating Manual
Setting the group name
1. [ MENU ] à “SETUP” à “MEMORY BOOK” à
“GROUP NAME”.
2. Press the [▲] or [▼] key to select the group including the entry you want to change, and then
press the [ENT] key.
3. Use the keypad to edit the letters and/or numbers
of the group name, then press the [ENT] key.
The cursor will move to the next digit of the group
name.
4. Select “FINISH” by pressing the [◄] or [►] key,
and then press the [ENT] key.
5. Press the PTT switch to return to normal operation.
31
Scanning Operation
The FTA-250L allows you to scan active channels automatically in the COMM (COM band), MR, and WX
modes. It pauses on signals received, so you can talk
to the station(s) on the frequency received.
Scanning Channels
1. Set the transceiver to the COMM mode.
2. Press the [ FUNC ] key
to display the Function
screen.
3. Select “SCAN” on the
screen by pressing the
[◄] or [►] key, and then
press the [ENT] key.
The scanning starts and
the display returns to the
COMM mode screen.
The “SC” icon appears
on the display.
 After the signal disappears, scanning resumes.
 To stop scanning, press the PTT switch or select
“SCAN” again in the Function screen.
Note: When you enable the alarm function at reception of the weather alert signal via the COMM
SETUP menu in the SETUP mode, the last
weather channel will be watched as the every
second frequency during a scan.
Example: When the last weather channel is 162.400
MHz (WX02), the transceiver scans in the
following order.
à
118.000
162.400 à 118.025 à
à 162.400 à 118.050 à 162.400 ...
The frequency of the last weather channel, however,
will not be displayed until the scanner encounters the
weather alert signal.
 The scanner searches signals from the lowest frequency to highest.
 When the scanner encounters a signal, the scanning pauses and the transceiver remains on that
channel until the signal disappears, and the frequency indication on the display blinks.
32
FTA-250L Operating Manual
Scanning Operation
Scanning the Specified Channels
Scanning the marked channels
Marking the channels
The FTA-250L operates in the same way as it does
when scanning all channels described in the previous page, except that it searches marked frequencies
only.
Among the memory and weather channels, you may
scan only those on which you want to see if a signal
exists.
1. Set the transceiver to the MR or WX mode and
tune to the channel that you want to be scanned.
2. Press the [FUNC] key.
3. Select “MEMO MEM” by
pressing the [ ◄ ] or [ ► ]
key, and then press the
[ENT] key.
 The current channel is
marked to be scanned
and the “ ” icon, which
indicates that the channel
is the target of scanning,
will appear at the top side
of the memory name when
the display returns to the
MR or WX mode screen.
4. Repeat steps 1 to 3 above to mark other channels
as well.
FTA-250L Operating Manual
1. Set the transceiver to the MR or WX mode.
2. The scanning starts and the display returns to the
MR or WX mode screen.
Note: When you enable the alarm function of the
weather alert signal via the COMM SETUP
menu in the SETUP mode, the last weather
channel will be watched as the every second
frequency during a scan.
Example: When the last weather channel is WX02
(162.4 MHz), the transceiver scans in the
following order.
001MEM à WX02 à 002MEM à
à WX02 à 003MEM à WX02 ...
The frequency of the last weather channel, however,
will not be displayed until the scanner encounters the
weather alert signal.
33
SETUP Mode
Note: We do not recommend that any of the default
settings be changed until you are thoroughly
familiar with the operation of the FTA-250L.
Basic Operation
1. Press the [MENU ] key to
display the MENU screen.
2. Select “SETUP” on the
MENU screen by pressing the [◄] or [►] key, and
then press the [ENT] key.
3. Select the desired menu
item by pressing the [ ▲ ]
or [▼] key, and then press
the [ENT] key.
4. Select the desired item by
pressing the [ ▲ ] or [ ▼ ]
key, and then press the
[ENT] key.
5. Select the desired setting
by pressing the [◄] or [►]
key.
Menu items
 MEMORY BOOK
You may store the frequencies with a tag name to
the memory of the transceiver, and maintain the
stored entries.
 COMM SETUP
You may set and adjust the operations of the
transceiver in the COM mode.
 PRIORITY CH
You may set the priority channel for dual watch.
 CONFIG
You may set and adjust the various configurations
of the radio.
 ABOUT...
Confirm the version of software installed in the radio.
6. Press the [ENT] key to store the selected setting.
7. Press the PTT switch to return to normal operation.
34
FTA-250L Operating Manual
SETUP Mode
Yo u m a y e n a b l e o r d i s able the quick access to the
121.500 MHz emergency frequency (see page 16).
Turning on/off the ANL (Automatic Noise Limiter)
You may enable or disable the
ANL (automatic noise limiter)
feature (see page 26).
Turning on/off the scan stop with the PTT
You may lock out the PTT
switch during the scan operation (see page 32).
Setting the scan resume time
You may select a waiting time
till the resuming of scan after
the encountered signal disappears.
The setting changes in the following order.
à2
à
Turning on/off the emergency call
You may enable or disable the
alarm function when receiving
the weather alert signal (see
pages 20).
à3
à
Setting of the COMM SETUP Mode Operation
Turning on/off the weather alert
à4
à
See pages 30 to 31 for details.
à 5 (SEC)
à
Maintenance of the Memory
Tip: The default setting: 3 SEC
Setting the noise cancel
You may cancel background
noise when transmitting and
receiving (see page 22).
FTA-250L Operating Manual
35
SETUP Mode
Setting the operation after stopping a scan
Setting the microphone configuration
You may select the operations
listed below when encountering a signal during a scan.
You may change the assignment of microphone controlled
with the PTT switch.(see page
23).
The setting changes in the following order.
Stays on the frequency and will not
resume the scan.
5 SEC STOP: Stays on the frequency for 5 seconds
and then resume the scan.
10 SEC STOP: Stays on the frequency for 10 seconds and then resume the scan.
Tip: The default setting: BUSY STOP
Setting the side tone operation
Setting the frequency step for tuning
You may select the operation
of the audio filter (see page
19).
BUSY STOP:
You may select the channel
steps of 8.33*/25 kHz per step
(see page 27).
* 8.33 kHz; Europe only
Setting the time-out timer for transmission
You may select a desired
remaining time for the TOT
function (see page 22).
36
You may monitor your own
voice when talking into the
microphone through the headphones (see page 25).
Setting the audio filter of the receiver
Turning on/off the VOX operation
You may enable or disable
the VOX function (see page
24).
FTA-250L Operating Manual
SETUP Mode
Setting the polled frequency for dual watch (see page
21).
You may adjust the loudness
in 5 levels.
The setting changes in the following order.
OFF
à
PRIORITY CH
Setting the loudness of key beeps
à1
à2
à
You may select a VOX delay
time of the VOX function (see
page 24).
à3
à
Setting the sensing time of the VOX system
à4
à
You may select a VOX gain of
the VOX function (see page
24).
Setting of the Operation and
Configuration of the Transceiver
à5
à
Setting the sensitivity of the VOX system
Tip: The default setting: 3
Battery Save
You may select the desired
interval of time for the battery
saver (see page 23).
KEY ASSIGNMENT
You may program the function assigned to the function
screen (see page 28).
FTA-250L Operating Manual
37
SETUP Mode
PTT LOCK
Setting the contrast of the display
You may enable or disable the
PTT lock function (see page
26).
You may adjust the contrast in
30 levels.
à
à
à
Setting the brightness of the display
The setting changes in the following order.
..... à LV29 à LV30
LV01 à LV02
You may adjust the backlight
brightness in 5 levels.
Tip: The default setting: LV15
The setting changes in the following order.
You may confirm the version of the software currently
operating on the transceiver.
à LV3
à
à LV2
à LV4
à
à
à LV1
à LV5
à
à
OFF
About the Transceiver
Tip: The default setting: LV5
Setting the lamp of the display
You may select the operation
of the display lighting from the
following 4 types.
OFF:
No lighting at any time
CONTINUOUS: Lights at all time
5 / 10 / 30 / 60 / 120 / 300 (sec)
Lights for selected time when any
key is pressed.
EXT PO/KEY: Lights for 5 seconds only when any
key is pressed, or lights at all time
when the power is supplied through
the EXT DC jack.
38
FTA-250L Operating Manual
SETUP Mode
Summary of the SETUP Menu
Memory Book
Item
ADD
EDIT
DELETE
GROUP NAME
Description
Adding new channels or
destinations
Editing the stored information
Deleting the stored channel or destination
Editing the group name
SC RESUME
SC STOP TYPE
Default Value
GP1 : GROUP-1
GP2 : GROUP-2
GP3 : GROUP-3
GP4 : GROUP-4
GP5 : GROUP-5
GP6 : GROUP-6
GP7 : GROUP-7
GP8 : GROUP-8
GP9 : GROUP-9
COMM SETUP
Item
EMERGENCY
CALL
ANL
NOISE CANCEL
WEATHER
ALERT
PTT SC STOP
Description
Turning on/off the emergency call
Turning on/off the automatic noise limiter
Setting the noise cancel
operation
Turning on/off the weather alert
Turning on/off the scan
stop with the PTT
FTA-250L Operating Manual
Default Value
ON
OFF
FREQ STEP
TX TOT
MIC SELECT
SIDE TONE
AF PITCH
CONT
VOX
VOX LEVEL
VOX DELAY
Setting the scan resume
time
Setting the operation after stopping a scan
Setting the frequency
step for tuning
Setting the time-out timer
for transmission
Setting the microphone
configuration
Setting the side tone operation
Setting the audio filter of
the receiver
Turning on/off the VOX
operation
Setting the sensitivity of
the VOX system
Setting the sensing time
of the VOX system
3 SEC
BUSY STOP
25 kHz
5 MIN
INTERNAL
OFF
NORMAL
OFF
LV2
1.5 SEC
PRIORITY CH
Item
Description
Setting the polled frequency for dual watch
Default Value
TX MODE : OFF
RX MODE : OFF
OFF
ON
39
SETUP Mode
CONFIG
Item
KEY BEEP
BATTERY SAVE
KEY ASSIGNMENT
PTT LOCK
BACKLIT LEVEL
BACKLIT TIMER
CONTRAST
Description
Default Value
Setting the loudness of
key beeps
Setting the power save
50 %
operation
Setting the function as- 1 : DUAL WATCH
signed to the function 2 : SCAN
screen
3 : SCAN MEM
4 : RX NOISE
5 : DIM/DISP
6 : LIGHT
Turning enable or disable
OFF
the PTT Lock function
Setting the brightness
LV5
level of the display
Setting the backlight
EXT PO/KEY
timer of the display
Setting the contrast of the
LV15
display
ABOUT...
Item
40
Description
Confirming the version of
the software
Default Value
FTA-250L Operating Manual
Specifications
General
Frequency Range:
TX: 118.000 to 136.975 MHz
RX: 118.000 to 136.975 MHz
161.650 to 163.275 MHz (Weather Channels; USA/Canada only)
Channel Spacing:
25 kHz/8.33 kHz (Europe only)
Emission Type:
TX: AM
RX: AM & FM (FM: for receiving the Weather Channels)
Supply Voltage:
6.0 to 9.5 VDC (Battery Terminal)
9.0 to 10.5 VDC (EXT DC JACK with Charging)
Current Consumption (approx.): 300 µA (power off),
70 mA (battery saver on, saver ratio 50%)
90 mA (squelch on), 300 mA (receive), 900 mA (transmit 1.5 W Carrier)
Temperature Range:
+14 ºF to + 140 ºF (–10 ºC to +60 ºC)
Case Size (W x H x D):
2.1 x 4.1 x 1.2 inches (52 x 105 x 30 mm) with SBR-25LI
Weight (approx.):
10.6 oz (300 g) with SBR-25LI, antenna and belt clip
Receiver
Circuit Type:
IFs:
Sensitivity:
Selectivity:
Adjacent CH. Selectivity:
AF Output (@7.4 V):
Transmitter
Power Output (@ 7.4 V):
Frequency Stability:
Modulation System:
Spurious Emission:
Int. Microphone Type:
Ext Mic. Impedance:
Double-conversion superheterodyne
47.25 MHz & 450 kHz
Better than 0.8 µV (for 6 dB S/N with 1 kHz, 30 % modulation)
Better than 8 kHz/–6 dB
Less than 25 kHz/–60 dB
0.7 W @ 16 Ohms, 10 % THD
5.0 W (PEP), 1.5 W (Carrier Power)
Better than ±1 ppm (+14 ºF to + 140 ºF [–10 ºC to +60 ºC])
Low Level Amplitude Modulation
>70 dB below carrier
Condenser
150 Ohms
Specifications are subject to change without notice or obligation.
FTA-250L Operating Manual
41
Troubleshooting For Headset Connection
Question
Answer
When connecting the SCU-15 headset adapter cable
” icon apbetween the radio and a headset, the “
pears on the display and the radio cannot be operated.
This happens when the plug on the SCU-15 headset adapter cable is not properly inserted into the MIC/SP jack. To make proper contact within the radio, the
plug must be pushed all the way into the MIC/SP jack and be fixed with the two
screws.
Can I purchase the optional PTT Switch from Yaesu?
Contact your Aviation dealer for details regarding purchasing an aftermarket
Push-To-Talk switch.
Will my headset work with this radio?
The SCU-15 headset adapter cable is made to operate with most headsets; however to be concretely sure check with the headset manufacturer using the wiring
shown below. Please confirm the connections and connector sizes are correct.
3.5mm plug
Speaker
PTT
Microphone
Ground
Speaker
PJ-055
(accepts 0.25” phone plug)
SCU-15
Microphone
PJ-068
(accepts 0.206” phone plug)
Headset specification requirements for SCU-15
Earphone (speaker) impedance:
Microphone impedance:
PTT pressed:
PTT not pressed:
42
8 Ω or above
150 Ω ±20%
Ground
Open
FTA-250L Operating Manual
Note
FTA-250L Operating Manual
43
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should
be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un
gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée quivalente (p.i.r.e.) ne dépassepas l’intensité nécessaire à l’établissement d’une communication satisfaisante.
This radio transmitter (identify the device by certification number, or model number if Category II) has been approved by Industry Canada
to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna
type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly
prohibited for use with this device.
Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de modèle s’il fait partie du matériel de
catégorie I) a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste, ou dont le gain est
supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.
Part 15.21: Changes or modifications to this device not expressly approved by YAESU MUSEN could void the user’s authorization to operate this device.
44
Attention in case of use
Disposal of your Electronic and Electric Equipment
This transceiver works on frequencies which are not
generally permitted. For frequency allocation, apply for a
license at your local spectrum management authority. For
actual usage contact
List of national codes
AT
BE BG CY CZ DE
your dealer or sales
DK ES
EE
FI
FR GB
shop in order to get
GR HR HU
IE
IT
LT
your transceiver adLU
LV
MT NL
PL
PT
justed to the allocated
RO SK
SI
SE CH
IS
LI
NO
–
–
–
–
frequency range.
Products with the symbol (crossed-out wheeled bin) cannot be disposed as household waste.
Electronic and Electric Equipment should be recycled at a
facility capable of handling these items and their waste by
products.
In EU countries, please contact your local
equipment supplier representative or service
center for information about the waste collection system in your country.
FTA-250L Operating Manual
Copyright 2017
YAESU MUSEN CO., LTD.
All rights reserved.
No portion of this manual may be
reproduced without the permission of
YAESU MUSEN CO., LTD.
YAESU MUSEN CO., LTD.
Tennozu Parkside Building
2-5-8 Higashi-Shinagawa, Shinagawa-ku, Tokyo
140-0002 Japan
YAESU USA
6125 Phyllis Drive, Cypress, CA 90630, U.S.A.
YAESU UK
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
1703-AS
Printed in Japan

Source Exif Data:

EXIF Metadata provided by EXIF.tools
FCC ID Filing: K6650023X20

Navigation menu