DESCRIPTION

TECHNICAL GUIDE
GAS-FIRED RESIDENTIAL
TWO STAGE STANDARD ECM
MULTI-POSITION GAS FURNACES
STANDARD & Low NOx MODELS
MODELS: TM8Y

These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized steel tubular
heat exchangers. The units are factory shipped for installation
in upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category I listed and may be common vented
with another gas appliance as allowed by the National Fuel Gas
Code.

FEATURES
•

NATURAL GAS
60 - 120 MBH INPUT
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at

www.upgnet.com and www.york.com
Additional rating information can be found at

www.ahridirectory.org

•
•
•
•

WARRANTY
20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applications.
Standard 5-year limited Parts warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replacement or closing for new home construction.

•

Two stage heating operation includes two stage gas valve,
two stage inducer operation and standard ECM blower
operation. Auto-staging allows two stage operation with a
single stage thermostat.
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Blower-off delay for cooling SEER improvement.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit current requirement for easy replacement
application.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
24V, 40 VA control transformer and integrated control
supplied for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow for
ductblaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation, burner, and blower operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Insulated blower compartment for thermal and acoustic
performance.
Low NOx models have been designed to meet specific
code requirements.
Venting applications may be installed as a common vent
with other gas-fired appliances or use a lined masonry
chimney.
1/4 turn knobs provided for easy independent door
removal.

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

5129592-YTG-A-0815
LEFT SIDE

FRONT

Vent Connection
Outlet
Electrical
Entry
Gas Pipe
Entry

Gas Pipe
Entry

33”

23”
Thermostat
Wiring

Thermostat
Wiring

14”

A

28.5”
29.5”

1”

1.5”

4” Diameter
Vent Connection
Outlet

24.38”

.5”

RIGHT SIDE

Electrical
Entry
Vent
Connection
Outlet

.5”
.5”

B

B

C

.5”

20”

24.25”

RETURN END

SUPPLY END

Cabinet and Duct Dimensions
Nominal

Cabinet Dimensions (Inches)

BTUH (kW)
Input

CFM (m3/min)

Cabinet
Size

A

B

C

TM8Y060A12MP11
TM8Y080B12MP11
TM8Y080C16MP11
TM8Y100C16MP11
TM8Y100C20MP11
TM8Y120C20MP11

1200 (34.0)
1200 (34.0)
1600 (45.3)
1600 (45.3)
2000 (56.6)
2000 (56.6)

A
B
C
C
C
C

14 1/2
17 1/2
21
21
21
21

13 3/8
16 3/8
19 7/8
19 7/8
19 7/8
19 7/8

10.3
11.8
13.6
13.6
13.6
13.6

Ratings & Physical / Electrical Data

Models

High Fire
Input

Low Fire
Input

High Fire
Output

Low Fire
Output

Nominal
Airflow

AFUE

Max
Over-Current
Protection

Max. Outlet
Air Temp

MBH

MBH

MBH

MBH

CFM

TM8Y060A12MP11

60

39

48

31.2

1200

80.0

15

160

°F

TM8Y080B12MP11

80

52

64

41.6

1200

80.0

15

160

TM8Y080C16MP11

80

52

64

41.6

1600

80.0

15

160

TM8Y100C16MP11

100

65

80

52

1600

80.0

15

160

TM8Y100C20MP11

100

65

80

52

2000

80.0

15

160

TM8Y120C20MP11

120

78

96

62.4

2000

80.0

15

160

Models

High Fire Air
Temp. Rise

Low Fire Air
Temp. Rise

°F

°F

HP

Amps

In.

Total Unit
Amps

Min. wire Size
(awg) @ 75 ft
one way

Operating
Weight

TM8Y060A12MP11

30-60

20-50

1/2

6.8

11 x 8

9.3

14

94

TM8Y080B12MP11

35-65

20-50

1/2

6.8

11 x 8

9.3

14

103

TM8Y080C16MP11

30-60

20-50

1/2

6.8

11 x 10

9.3

14

114

TM8Y100C16MP11

30-60

20-50

1/2

6.8

11 x 10

9.3

14

118

TM8Y100C20MP11

30-60

20-50

3/4

8.4

11 x 11

10.9

14

122

TM8Y120C20MP11

35-65

20-50

3/4

8.4

11 x 11

10.9

14

129

Blower
Size

Blower

Lbs.

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.

2

Johnson Controls Unitary Products

5129592-YTG-A-0815

HORIZONTAL SIDEWALL VENTING

NOTICE

For applications where vertical venting is not possible, the only
approved method of horizontal venting is the use of an auxiliary
power vent. Auxiliary power venter's must be approved by CSA,
UL, or other recognized safety agencies. Follow all application
and installation details provided by the manufacturer of the
power vent.

Single side return above 1800 CFM is approved as long as
the filter velocity does not exceed filter manufacturer’s recommendation and a transition is used to allow use on a
20x25 filter.
Recommended Filter Sizes

FILTER PERFORMANCE
The airflow capacity data published in the “Blower Performance” table shown represents blower performance WITHOUT
filters.
All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace.

CFM

Cabinet
Size

Side
(in)

Bottom
(in)

1200

A

16 x 25

14 x 25

1200

B

16 x 25

16 x 25

1600

C

16 x 25

20 x 25

2000

C

(2) 16 x 25

20 x 25

1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters.
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one return with a transition to allow use of a 20x25 filter.

Unit Clearances to Combustibles (All Dimensions in Inches, and All Surfaces Identified with the Unit in an Upflow Configuration)
Application

Top

Front

Rear

In. (cm) In. (cm) In. (cm)

Left Side

Right Side

Flue

In. (cm)

In. (cm)

In. (cm)

Floor/
Bottom

Closet

Alcove

Attic

Line
Contact

Upflow
Upflow B-Vent

1 (2.5)
1 (2.5)

1 (2.5)
1 (2.5)

0 (0.0)
0 (0.0)

0 (0.0)
0 (0.0)

0 (0.0)
0 (0.0)

6 (15.2)
1 (2.5)

Combustible
Combustible

Yes
Yes

Yes
Yes

Yes
Yes

No
No

Downflow

1 (2.5)

1 (2.5)

0 (0.0)

0 (0.0)

0 (0.0)

6 (15.2)

1 (25.4)1

Yes

Yes

Yes

No

Downflow B-Vent

1 (2.5)

1 (2.5)

0 (0.0)

0 (0.0)

0 (0.0)

1 (2.5)

1 (25.4)1

Yes

Yes

Yes

No

Horizontal

1 (2.5)

1 (2.5)

0 (0.0)

0 (0.0)

0 (0.0)

6 (15.2)

Combustible

No

Yes

Yes

Yes2

Horizontal B-Vent

1 (2.5)

1 (2.5)

0 (0.0)

0 (0.0)

0 (0.0)

1 (2.5)

Combustible

No

Yes

Yes

Yes2

1. Combustion floor base accessory or air conditioning coil required for use on combustible floor.
2. Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal position) of the furnace jacket and building
joists, studs or framing.

ACCESSORIES
Propane (LP) Conversion Kit 1NP0347 - All Models
This accessory conversion kit may be used to convert natural
gas units for propane (LP) operation.
Side Return Filter Racks 1SR0200 - All Models
1SR0302 - All Models
1SF0101 - All Models
Bottom Return Filter Racks 1BR0514 or 1BR0614 - For 14-1/2” cabinets
1BR0517 or 1BR0617 - For 17-1/2” cabinets
1BR0521 or 1BR0621 - For 21” cabinets
1BR05xx series are galvanized steel filter racks. 1BR06xx are
pre-painted steel filter racks to match the appearance of the furnace cabinet.
Masonry Chimney Kits For installations where these furnaces are vented using existing
or new lined masonry chimneys.
1CK0603
1CK0604

Johnson Controls Unitary Products

Combustible Floor Base Kit For installation of these furnaces in downflow applications
directly onto combustible flooring material, These kits are
required to prevent potential overheating situations. These kits
are also required in any applications where the furnace in
installed in a downflow configuration without an evaporator coil,
where the combustible floor base kit provides access for combustible airflow.
1CB0514 - For 14-1/2” cabinets
1CB0517 - For 17-1/2” cabinets
1CB0521 - For 21” cabinets
High Altitude Pressure Switches For installation where the altitude is less than 5,000 feet it is not
required that the pressure switch be changed. For altitudes
above 5,000 feet, see kits below.
1PS3309
Thermostats - Compatible thermostat controls are available
through accessory sourcing. For optimum performance and
installation, refer to the UPGNET “Low Voltage Wiring Diagram”
document to select and apply controls.

3

Blower Performance CFM - Any Position (without filter)
Airflow Data (SCFM)1, 2
Models

Speed

Ext. Static Pressure (in. H2O)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1260

1220

1180

1150

1110

1070

1030

990

940

900

Medium High

1160

1120

1080

1030

990

950

900

850

800

760

Medium

1010

960

920

880

830

780

740

680

640

590

Medium Low

860

810

770

710

670

580

560

510

460

410

Low

800

760

710

650

610

550

500

460

390

350

High

1330

1300

1270

1240

1210

1160

1130

1090

1050

1000

Medium High

1140

1100

1070

1020

990

950

900

850

800

760

Medium

990

960

920

870

830

780

730

680

630

580

Medium Low

920

890

840

790

740

700

640

600

550

510

Low

820

770

730

680

630

580

540

480

430

390

High

1730

1700

1660

1610

1580

1520

1470

1410

1360

1300

Medium High

1560

1530

1490

1450

1400

1350

1310

1270

1220

1170

Medium

1370

1330

1280

1230

1180

1130

1080

1030

970

910

Medium Low

1190

1140

1090

1040

990

930

870

820

750

680

Low

1000

940

880

820

750

680

600

540

460

410

High

1730

1690

1650

1610

1570

1530

1470

1420

1360

1310

Medium High

1570

1530

1490

1440

1400

1360

1320

1270

1220

1170

Medium

1360

1310

1260

1220

1180

1130

1070

1010

950

890

Medium Low

1210

1160

1110

1050

1000

940

880

810

760

700

Low

1010

950

900

820

760

680

610

540

500

430

High

2230

2180

2130

2070

2020

1960

1900

1850

1790

1720

Medium High

1820

1780

1740

1680

1620

1580

1530

1470

1410

1350

Medium

1610

1550

1500

1440

1390

1340

1280

1230

1170

1110

Medium Low

1440

1380

1320

1270

1210

1150

1090

1030

960

890

Low

1210

1150

1080

1020

960

890

820

740

680

640

High

2150

2020

2040

1990

1930

1880

1820

1770

1720

1660

Medium High

1780

1740

1690

1640

1590

1540

1490

1430

1380

1310

Medium

1580

1520

1470

1420

1370

1320

1270

1220

1160

1090

Medium Low

1410

1350

1290

1240

1180

1130

1070

1020

950

890

Low

1190

1130

1060

1000

940

880

820

760

680

630

High
060A12

080B12

080C16

100C16

100C20

120C20

1. Airflow expressed in standard cubic feet per minute (SCFM).
2. Motor voltage at 115 V.
Note: Operation at external static pressure higher than rating on furnace data plate is not recommended.

EXTERNAL STATIC PRESSURE SETUP
Set appropriate airflow per temperature rise for gas heating. Set
appropriate airflow per Table 14 for cooling/heat pump heating
operating based on outdoor unit size and external static pressure.

Supply Duct

To measure external static pressure:
•
Measure the supply air static pressure
•
Record this positive number
•
Measure the return air static pressure
•
Record this negative number
•
Treat the negative number as a positive and add the two
numbers together
•
This is total system static

Return
Duct

Subject to change without notice. Published in U.S.A.
Copyright © 2015 by Johnson Controls, Inc. All rights reserved.

York International Corp.
5005 York Drive
Norman, OK 73069

5129592-YTG-A-0815
Supersedes: Nothing



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Author                          : csardom
Create Date                     : 2015:08:19 14:17:11-05:00
Modify Date                     : 2015:08:19 14:27:59-05:00
XMP Toolkit                     : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15
Format                          : application/pdf
Title                           : 5129592-YTG-A-0815.fm
Creator                         : csardom
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2015:08:19 14:27:59-05:00
Producer                        : Acrobat Distiller 15.0 (Windows)
Document ID                     : uuid:19bd860e-8722-4cb9-ab21-56f8312fff5c
Instance ID                     : uuid:1aa55c0d-fb56-44f4-ab83-c8bf51e0fd0a
Page Layout                     : OneColumn
Page Mode                       : UseThumbs
Page Count                      : 4
EXIF Metadata provided by EXIF.tools

Navigation menu