York Zf Sunline R410A Users Manual 1056292 XTG A 0613
XTG 1056292-XTG-A-0613
2015-09-09
: York Zf-Sunline-R410A-Users-Manual york-zf-sunline-r410a-users-manual-812386 york pdf
Open the PDF directly: View PDF
.
Page Count: 38
| Download | |
| Open PDF In Browser | View PDF |
1056292-XTG-A-0613 ® TECHNICAL GUIDE R-410A ZF SERIES 15 & 20 TON/53 & 70 KW 50 Hertz Description YORK® ZF Series Sunline™ units are convertible single package high efficiency rooftops. All models have independent refrigeration circuits for efficient part load operation. Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof. All ZF units are self-contained and assembled on rigid full perimeter base rails allowing for overhead rigging. Every unit is completely charged, wired, piped, and tested at the factory to provide a quick and easy field installation. All models (including those with an economizer) are convertible between bottom and horizontal duct connections. ZF units are available in the following configurations: cooling only, cooling with electric heat, and cooling with gas heat. Electric heaters are available as factory-installed options only. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 1056292-XTG-A-0613 Table of Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Capacity Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Airflow Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Sound Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 2 Johnson Controls Unitary Products 1056292-XTG-A-0613 Component Location (ZF shown) 20 GAUGE ALUMINIZED STEEL TUBULAR HEAT EXCHANGERS ELECTRIC HEATER LOCATION (OPTIONAL ELECTRIC/ELECTRIC UNITS) HIGH EFFICIENCY COMPRESSORS COPPER TUBE/ALUMINUM FIN CONDENSER COILS LONG LASTING POWDER PAINT FINISH ELECTRICAL DISCONNECT MOUNTING LOCATION (Field installed) KNOCKOUT FOR SIDE CONTROL WIRING ENTRY KNOCKOUT FOR SIDE POWER WIRING ENTRY SIDE 2" DISPOSABLE FILTERS POWER VENTOR MOTOR WITH POST PURGE CYCLE KNOCKOUTS FOR SIDE GAS SUPPLY ENTRY HOLE FOR BOTTOM GAS SUPPLY ENTRY BELT-DRIVE BLOWER MOTOR 1" NPTI CONDENSATE DRAIN GAS/ELECTRIC UNIT SHOWN FULL PERIMETER 14 GAUGE BASE RAILS WITH LIFTING HOLES Johnson Controls Unitary Products 3 1056292-XTG-A-0613 Nomenclature 15 & 20 Ton Sunline Model Number Nomenclature Z F 180 N24 A 7 A AA 1 0 1 2 4 A Product Category Product Style Z = A/C, Single Pkg. A = Style A Product Identifier Configuration Options (not required for all units) These four digits will not be assigned until a quote is requested, or an order placed. F = R-410A SS Drain Pan CPC Controller, DFS, APS Nominal Cooling Capacity Johnson Controller, DFS, APS Honeywell Controller, DFS, APS 180 = 15 Ton 240 = 20 Ton Novar Controller, DFS, APS Simplicity IntelliComfort Controller Simplicity IntelliComfort Controller w/ModLinc Heat Type and Nominal Heat Capacity 2" Pleated filters C00 = Cooling Only. No field installed electric heat 4" Pleated filters BAS Ready Economizer (2-10 V.D.C. Actuator without a controller) Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned Gas Heat Options N24 = 240 MBH Output Aluminized Steel N32 = 320 MBH Output Aluminized Steel S24 = 240 MBH Output Stainless Steel S32 = 320 MBH Output Stainless Steel Product Generation 1 = First Generation Electric Heat Options Additional Options E18 = 18 KW E36 = 36 KW E54 = 54 KW E72 = 72 KW Airflow A = Hi Static B = Hi Static/Economizer C = Hi Static/Economizer/Power Exhaust (Downflow Only) D = Hi Static/Motorized Damper E = Hi Static/Motorized Damper/Barometric Relief J = Hi Static/Economizer/Barometric Relief Standard Cabinet Hinged Filter Door & Tool Free Access Cabinet AA = None AB = Phase Monitor AC = Coil Guard AD = Dirty Filter Switch AE = Phase Monitor & Coil Guard AF = Phase Monitor & Dirty Filter Switch AG = Coil Guard & Dirty Filter Switch AH = Phase Monitor, Coil Guard & Dirty Filter Switch RC = Coil Guard & American Flag TA = Technicoat Condenser Coil TJ = Technicoat Evaporator Coil TS = Technicoat Evaporator & Condenser Coils BA = Hinged Filter Door & Tool Free Access Panels BB = Phase Monitor, Hinged Filter Door & Tool Free Access Panels BC = Coil Guard, Hinged Filter Door & Tool Free Access Panels BD = Dirty Filter Switch, Hinged Filter Door & Tool Free Access Panels BE = Phase Monitor & Coil Guard, Hinged Filter Door & Tool Free Access Panels BF = Phase Monitor & Dirty Filter Switch, Hinged Filter Door & Tool Free Access Panels BG = Coil Guard & Dirty Filter Switch, Hinged Filter Door & Tool Free Access Panels BH = Phase Monitor, Coil Guard & Dirty Filter Switch, Hinged Filter Door & Tool Free Access Panels Voltage 7 = 380/415-3-50 ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be located in digits 15-18. Installation Options A = No Options Installed B = Option 1 E = Option 3 F = Option 4 G = Options 1 & 3 H = Options 1 & 4 L = Options 1,3 & 4 R = Options 3 & 4 Options 1 = Disconnect 3 = Smoke Detector S.A. 4 = Smoke Detector R.A. 4 Johnson Controls Unitary Products 1056292-XTG-A-0613 Features and Benefits Standard Features • High Efficiency - High efficiency units reach as high as 10.9 EER. Gas/electric units have electronic spark ignition and power vented combustion with steady state efficiencies of 80%. • Balanced Heating • Gas Heat - All gas heat units are built with two heating sections for two equal stages of capacity control. Each section includes a durable heat exchanger with aluminized steel or optional stainless steel tubes, a redundant gas valve, spark ignition, power venting, an ignition module for 100% shut-off and all of the safety controls required to meet the latest ANSI standards. The gas supply piping can be routed into the heating compartment through a hole in the base pan of the unit or through a knockout in the piping panel on the front of the unit. • Electric Heat - All electric heat models (factory installed only) are wired for a single power source and include a bank of nickel chromium elements mounted at the discharge of the supply air blower to provide a high velocity and uniform distribution of air across the heating elements. Every element is fully protected against excessive current and temperature by fuses and two thermal limit switches. The power supply wiring can be routed into the control box through a threaded pipe connection in the base pan of the unit or through a knockout in the wiring panel on the front of the unit. • BAS Controls - York’s Sunline™ series units offer factory mounted BAS controls such as Simplicity ® Intelli-Comfort II ™, Novar, Honeywell, Johnson, York Commercial Comfort System (YCCS) and CPC. • Convertible Airflow Design - All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with factory installed power exhaust are suitable for bottom duct connections only. For bottom duct, you remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, you replace the supply and return air panels on the rear of the unit with a side duct flange accessory. • Factory Mounted Outdoor Air Dampers - All models are available with these "factory mounted" outdoor air damper options: • Single enthalpy economizer with or without power exhaust • BAS-ready economizer with or without power exhaust • Motorized outdoor air damper • Barometric Relief Damper A fixed outdoor air intake assembly will be shipped in the return air compartment of all units ordered without an economizer or motorized outdoor air damper option. The assembly includes a rain hood with a damper that can be set for 10, 15 or 25% outdoor air. With bottom duct connections, the fixed outdoor air intake assembly should be mounted Johnson Controls Unitary Products over the opening in the return air panel. With horizontal ductwork, it should be mounted on the return air duct. • System Protection - Suction line freezestats are supplied on all units to protect against loss of charge and coil frosting when the economizer operates at low outdoor air temperatures while the compressors are running. Every unit has solid-core liquid line filter-driers and high and lowpressure switches. Internal compressor protection is standard on all compressors. Phase Monitors are optional on all units. This accessory monitors the incoming power to the unit and protects the unit from phase loss and reversed phase rotation. • Advanced Controls - Simplicity™ ZF control boards have standardized a number of features previously available only as options or by utilizing additional controls. • Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0F outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temperature is low or when free cooling is available. The Simplicity® control board used in this product will effectively operate the cooling system down to 25°F when this product is applied in a comfort cooling application for people. An economizer is typically included in this type of application. When applying this product for process cooling applications (computer rooms, switchgear, etc.), please reference applications bulletin AE-011-07 or call the applications department for Unitary Products @ 1877-UPG-SERV for guidance. • Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti-short cycle delay can be temporarily overridden with the push of a button. • Lead-Lag - An integrated Lead-Lag option allows equal run time hours on all compressors, thereby extending the life of all compressors. This option is selectable on the unit control board. • Fan Delays - Fan on and fan off delays are fully programmable. Furthermore, the heating and cooling fan delay times are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat. • Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit control board will alarm on ignition failures, compressor lockouts and repeated limit switch trips. • Nuisance Trip Protection and Strikes - To prevent nuisance trouble calls, the control board uses a “three 5 1056292-XTG-A-0613 • • • • • times, you’re out” philosophy. The high and lowpressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the associated compressor. • On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and low-pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power. Reliable - From the beginning - All units undergo computer automated testing before they leave the factory. Units are tested for refrigerant charge and pressure, unit amperage, and 100% functionality. For the long term - All units are painted with a long lasting, powder paint that stands up over the life of the unit. The paint used has been proven by a 1000 hour salt spray test. Full Perimeter Base Rails - The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails offer rigging holes so that an overhead crane can be used to place the units on a roof. Easy Installation - Gas and electric utility knockouts are supplied in the unit underside as well as the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. All units are shipped with 2" throw-away filters installed. Wide Range of Indoor Airflows - All supply air blowers are equipped with a belt drive that can be adjusted to meet the exact requirements of the job. Warranty - All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements each carry a 5-year warranty. Aluminized steel and stainless steel tubular heat exchangers carry a 10year warranty. Factory Installed Options YORK® offers several equipment options factory installed, for the ZF Series. • Single Input Electronic Enthalpy Economizers Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. The rainhood is painted to match the basic unit and must be field-assembled before installing. • BAS-Ready Economizer - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator with zero to 95-degree rotation capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. Actuator requires 2-10 VDC input from an external source, such as a field-installed or factory-installed BAS 6 controller. BAS-ready actuators have an adjustable auxiliary end-switch for optional power exhaust control. For units with optional VAV or Simplicity® Intelli-Comfort II™ control, a factory-installed, dry bulb sensor determines if outdoor air temperature is low enough to provide free-cooling operation. (Field-installed humidity sensors for either outdoor air or outdoor & return air streams are available for single enthalpy and differential enthalpy configurations, respectively). The rain hood is painted to match the basic unit and must be field-assembled before installing. • Power Exhaust - Our economizer options are available with power exhaust. Whenever the outdoor air intake dampers are opened for free cooling, the exhaust fan will be energized to prevent the conditioned space from being over-pressurized during economizer operation. The exhaust fan, motor and controls are installed and wired at the factory. The rain hood must be assembled and installed in the field. The power exhaust option can only be used on bottom duct configurations. • Motorized Outdoor Air Intake Damper - Includes a slide-in / plug-in damper assembly with a 2- position, spring return motor actuator which opens to a pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. • Barometric Relief Damper - This damper option can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. • Technicoat Condenser Coils - The condenser coils are coated with a phenolic coating for protection against corrosion due to harsh environments. • Technicoat Evaporator Coil - The evaporator coils are coated with a phenolic coating for protection against corrosion due to harsh environments. • Electric Heaters - wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures. • Filter Options - Standard units are shipped with 2" throwaway filters installed. 2" pleated and 4" pleated filters are offered as a factory installed option. • Disconnect Switch - For gas heat units and cooling units with electric heat, a HACR breaker sized to the unit is provided. For cooling only units, a switch sized to the largest electric heat available for the particular unit is provided. Factory installed option only. • York Commercial Comfort System (YCCS) - Provides rooftop system integration for YCCS single zone, changeover bypass and VAV systems. Johnson Controls Unitary Products 1056292-XTG-A-0613 • Smoke Detectors - (supply air & return air) The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. Factory installed smoke detectors in the return air, may be subjected to freezing temperatures during “off” times due to out side air infiltration. these smoke detectors have an operational limit of 32°F to 131°F. smoke detectors installed in areas that could be out side those limitations will have to be moved to prevent having false alarms. • Coil Guard - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. • Stainless Steel Heat Exchanger - For applications in corrosive environments, this option provides a full stainless steel heat exchanger assembly. • Stainless Steel Drain Pan - An optional rustproof stainless steel drain pan is available to provide years of trouble-free operation in corrosive environments. • Phase Monitors - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-of phase condition. • Dirty Filter Switch - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory. • Hinged Filter Door/"Tool Free" Blower And Access Panels (Not Hinged) - This option allows for easy access and maintenance. NOTE: Knobs are shipped separately within the unit to prevent shipping damage. These must be field installed for tool free operation. • Hinged/"Tool Free" Blower, Blower Motor, Filter And Electric Access Panels - This option allows for complete hinged and tool free access to the unit’s blower, blower motor, filters and electrical panel sections. Control Options • BAS - Building Automation System Controls (available on two-system cooling product only). Simplicity™ Intelli-Comfort II™ Control - The York® Simplicity™ INTELLI-CO2 sensor to perform Differential Demand Ventilation. It uses a Patented Comfort Ventilation algorithm to provide comfortable ventilation air temperature. The patented economizer-loading algorithm will protect the equipment when harsh operating conditions exist. It uses the INTELLI-Start™ algorithm to maximize energy savings by recovering the building from the Unoccupied Setpoints to the Occupied Setpoints just in time for the Occupied Time Period to begin. The Simplicity™ Intelli-Comfort II™ balances space temperature, ventilation air temperature, CO2 and humidity for ultimate comfort. Johnson Controls Unitary Products Simplicity™ Intelli-Comfort II™ with Simplicity™LINC Control - The York® Simplicity™ Intelli-Comfort II™ with Simplicity™LINC control is factory installed. It includes all the features of the Intelli-Comfort II™ control with an additional control to translate communications from MODBUS to the BACnet MSTP protocol. Novar® BAS Control - The Novar® building automation system controller is factory installed. Incudes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. Johnson Controls BAS Control - The Johnson Control YK-UNT-1126 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. CPC BAS Control - The Computer Process Controls Model 810-3060 ARTC Advanced Rooftop building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch and air proving switch. Honeywell BAS Control - The Honeywell W7750C building automation system controller is factory installed. Includes air supply sensor, return air sensor, dirty filter indicator switch, and air proving switch. Field Installed Accessories YORK® offers several equipment accessories for field installation, for the ZF Series. • Single Input Electronic Enthalpy Economizers Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. The rain hood is painted to match the basic unit and must be field-assembled before installing. • Motorized Outdoor Air Intake Damper - Includes a slide-in / plug-in damper assembly with a 2-position, spring return motor actuator which opens to some pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. • Roof Curbs - Fourteen-inch high roof curbs provide a water-tight seal between the unit and the finished roof. These full perimeter curbs meet the requirements of the National Roofing Contractors Association (NRCA) and are shipped knocked-down for field assembly. They're designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger supports. • High Altitude Natural Gas - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up to 6,000 feet. • Propane - Burner orifices, pilot orifices and gas valve parts are provided to convert a natural gas furnace to propane. • High Altitude Propane - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up 7 1056292-XTG-A-0613 • • • • • • • • • to 6,000 feet. This accessory supplements the basic propane conversion kit. Side Duct Flanges - One-inch flanges replace the supply and return air panels on the rear of the unit to accommodate horizontal duct connections. These flanges can also be used individually for bottom supply / horizontal return or horizontal supply/bottom return. They cannot be used on units with power exhaust. Barometric Relief Damper - This damper accessory can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. Enthalpy Accessory Control Kit - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy. Burglar Bars - Mount in the supply and return openings to prevent entry into the duct work. Flue Exhaust Extension Kit - In locations with wind or weather conditions which may interfere with proper exhausting of furnace combustion products, this kit can be installed to prevent the flue exhaust from entering nearby fresh air intakes. Wood Skid - Allows unit to be handled with 90" forks. CO2 Sensor - Senses CO2 levels and automatically overrides the economizer when levels rise above the present limits. Coil Guard - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. Phase Monitors - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-of phase condition. Guide Specifications General Units shall be manufactured by Johnson Controls Unitary Products in an ISO 9001 certified facility. ZF models have 2 condenser fan motors and compressors. All compressors include crankcase heat and internal discharge temperature protection. Every refrigerant circuit includes an expansion valve, a liquid line filter-drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch. The unit control circuit includes 75 VA and 150 VA transformers, a 24-volt circuit breaker and a relay board with two compressor lockout circuits, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All units have long lasting powder paint cabinets with 1000 hour salt spray test approval under ASTM-B117 procedures. All models include a 1-year limited warranty on the complete unit. 8 Compressors and electric heater elements carry an additional 4-year warranty. Aluminized steel tubular heat exchangers carry an additional 9-year warranty. Description ZF units shall be factory-assembled, single packaged, ZF***N Electric Cooling/Gas Heat, ZF***C/E Electric Cooling/Optional Electric Heat, designed for outdoor mounted installation. They shall have built-in field convertible duct connections for down discharge supply/return or horizontal discharge supply/ return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R-410A refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units shall be manufactured in a facility certified to ISO 9001 standards and the cooling performance shall be rated in accordance with DOE and AHRI test procedures. Units shall be classified to ANSIZ21.47 standards, UL 1995/CAN/CSA No. 236-M90 conditions. Unit Cabinet Unit cabinet shall be constructed of galvanized steel, with exterior surfaces coated with a non-chalking, powdered paint finish, certified at 1000 hours salt spray test per ASTM-B117 standards. Indoor blower section shall be insulated with a minimum 1/2" thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with rigid fasteners to prevent insulation from entering the air stream. Cabinet panels shall be easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 2" filters shall be furnished and be accessible through a removable access door, sealed airtight. Units filter track shall be designed to accommodate either 2" or 4" filters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air by-pass of the coils. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining standards. Condensate connection shall be a minimum of 1" I.D. female and be a ridged mount connection. Unit shall incorporate a fixed outdoor air damper with an outdoor air intake opening covered with a bird screen and a rain hood painted to match the exterior of the unit. Indoor (Evaporator) Fan Assembly Fan shall be a belt drive assembly and include an adjustablepitch motor pulley. Job site selected (B.H.P.) brake horsepower shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Johnson Controls Unitary Products 1056292-XTG-A-0613 Outdoor (Condenser) Fan Assembly The outdoor fans shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider brackets and shall be dynamically balanced for smooth operation. The 2 outdoor fan motors shall be totally enclosed with permanently lubricated bearings, internally protected against overload conditions and staged independently. Refrigerant Components e. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. f. Unit control board shall have on-board diagnostics and fault code display. g. Standard controls shall include anti-short cycle and low voltage protection, and permit cooling operation down to 25°F. h. Control board shall monitor each refrigerant safety switch independently. Compressors: a. Shall be Scroll compressors internally protected with internal discharge temperature protection over temperature protection. b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Evaporator and condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator and Condenser coils shall be of the direct expansion, draw-thru, design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Balance-port thermostatic expansion independent circuit feed system. d. Unit shall incorporate "AUTO RESET" compressor over temperature, over current protection. valve with i. Control board shall retain last 5 fault codes in non volatile memory, which will not be lost in the event of a power loss. Gas Heating Section (ZF***N Models) Shall be designed with induced draft combustion with post purge logic and energy saving direct spark ignition, redundant main gas valve. Ventor wheel shall be constructed of stainless steel for corrosion resistance. The heat exchanger shall be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 25 °F. Burners shall be of the in-shot type, constructed of aluminum coated steel and contain air mixture adjustments. All gas piping shall enter the unit cabinet at a single location through either the side or curb, without any field modifications. An integrated control board shall provide timed control of evaporator fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: b. Filter drier/strainer to eliminate any moisture or foreign matter. a. Primary and auxiliary high-temperature limit switches. c. Accessible service gage connections on both suction and discharge lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. c. Flame roll out switch (automatic reset). d. The refrigeration system shall provide at least 10° F of sub-cooling at design conditions. e. All models shall have two independent circuits. Unit Controls a. Unit shall be complete with self-contained low-voltage control circuit protected by a resettable circuit breaker on the 24-volt transformer side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor. c. Loss-of-charge/Low-pressure switch. 1. High-pressure switch. 2. Freeze-protection thermostat, evaporator coil. If any of the above safety devices trip, a LED (light-emitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. Johnson Controls Unitary Products b. Induced draft motor speed sensor. d. Flame proving controls. Unit shall have two independent stages of capacity. Electric Heating (ZF***C/E Models) Nickel chromium electric heating elements shall be provided as required by the application with 1 or 2 stage control, as required, from 18 KW to 72 KW nominal capacities. The heating section shall have a primary limit control(s) and automatic reset to prevent the heating element system from operating at an excessive temperature. Units with Electric Heating shall be wired for a single point power supply with branch circuit fusing (where required). Unit Operating Characteristics Unit shall be capable of starting and running at 125° F outdoor temperature, exceeding maximum load criteria of AHRI Standard 340/360. The compressor, with standard controls, shall be capable of operation down to 25° F outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up (Gas heat only). 9 1056292-XTG-A-0613 Electrical Requirements • 100% Barometric Relief Damper - Contains a rain hood, air inlet screen, exhaust damper and mounting hardware. Used to relieve internal air pressure through the unit. All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. • Propane Conversion Kit - Contains new orifices and gas valve parts to convert from natural to L.P. gas. One per unit required. Standard Limited Warranties • High Altitude - Natural Gas - Contains orifices required for applications between 2000 and 6000 feet altitude. • Compressor 5 Years • Heat Exchanger 10 Years • Electric Heat Element 5 Years • Other Parts 1 Year Optional Outdoor Air (Shall be made available by either/or): • Electronic Enthalpy Automatic Economizer - Outdoor and return air dampers that are interlocked and positioned by a fully-modulating, spring-return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in CFM of outdoor air to meet the minimum ventilation requirement of the conditioned space during normal operation. During economizer operation, a mixed-air temperature control shall modulate the outdoor and return air damper assembly to prevent the supply air temperature from dropping below 55°F. Changeover from compressor to economizer operation shall be provided by an integral electronic enthalpy control that feeds input into the basic module. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. • Motorized Outdoor Air Dampers - Outdoor and return air dampers that are interlocked and positioned by a 2position, spring-return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in the design CFM of outdoor air to meet the ventilation requirements of the conditioned space during normal operation. Whenever the indoor fan motor is energized, the dampers open up to one of two pre-selected positions - regardless of the outdoor air enthalpy. Dampers return to the fully closed position when the indoor fan motor is de-energized. Dampers shall fully close on power loss. • High Altitude - Propane Gas - Contains orifices required for applications between 2000 and 6000 feet altitude. Must be used with propane conversion kit. • Burglar Bars - Designed to work with above roof curbs, depending on unit model. Fits duct openings of curb supply and return air openings. • Side Duct Flange - Supply and return air duct flanges for side duct applications. Do not use on units with power exhaust. • Wood Skid - Allows unit to be handled with 90" forks. • Economizer/motorized Damper Rain Hood (ZFN/E/C240 only) - Contains all hood panels and the hardware for assembling. • Anti-Recycle Timer - Assures 5-minute off time between compressor cycles. • Coil Guard Kit - Guard for cooling coil. OTHER FACTORY INSTALLED OPTIONS • Power Exhaust Option - To work in conjunction with economizers. • Stainless Steel Heat Exchanger • Stainless Steel Drain Pan • Technicoat Phenolic Coated Condenser And Evaporator Coil • Electronic Single Enthalpy Economizer • Dirty Filter Switch • Phase Monitor • Coil Guard • Bas Controls - Simplicity ® Intelli-Comfort II ™, CPC, JOHNSON, HONEYWELL, NOVAR, YORK COMMERCIAL COMFORT SYSTEM (YCCS) • BAS Ready Economizer (2-10 V.D.C. Actuator Without a Controller) • Hinged Filter Door Access And Tool Free Access Panels • Hinged Tool Free Blower, Blower Motor, Filter And Electrical Access Panels • 2" Pleated Filters, MERV 7 • 4" Pleated Filters, MERV 13 Other Pre-engineered Accessories Available • Roof Curb - 14" high, full perimeter curb with wood nailer (shipped knocked-down). 10 • Disconnect Switch • Supply Air Smoke Detector • Return Air Smoke Detector Johnson Controls Unitary Products 1056292-XTG-A-0613 Physical Data ZF180-240 Physical Data Models Component ZF180 ZF240 15 20 Gross Capacity @ AHRI A point (K Btu) 204 259 AHRI net capacity (K Btu) 195 246 EER 10.9 10.4 Nominal Tonnage AHRI COOLING PERFORMANCE SEER - - IEER 11.26 10.88 Nominal CFM 6000 8000 System power (KW) 17.9 23.7 R-410A R-410A System 1 22-8 20-4 System 2 21-8 21-4 Refrigerant type Refrigerant charge (lb-oz) AHRI HEATING PERFORMANCE Heating model 24 32 24 32 Heat input (K Btu) 300 400 300 400 Heat output (K Btu) 240 320 240 320 - - - - 80 80 80 80 AFUE% Steady state efficiency (%) No. burners 6 8 6 8 No. stages 2 2 2 2 20-50 35-65 20-50 35-65 195 195 195 195 1 1 1 1 Temperature Rise Range (ºF) Gas Limit Setting (ºF) Gas piping connection (in.) DIMENSIONS (inches) Length 125-1/4 Width 92 92 Height 48-5/8 52-5/8 1680 2400 Scroll Scroll OPERATING WT. (lbs.) 136-1/4 COMPRESSORS Type Quantity Unit Capacity Steps (%) 2 2 50 / 100 50 / 100 36.0 43.3 CONDENSER COIL DATA Face area (Sq. Ft.) Rows Fins per inch Tube diameter (in.) Circuitry Type 3 3 13.5 15 3/8 3/8 Standard Standard 15.5 20.1 EVAPORATOR COIL DATA Face area (Sq. Ft.) Rows 4 4 Fins per inch 14 14 Tube diameter 3/8 3/8 Circuitry Type Intertwined Intertwined TXV TXV Refrigerant control Johnson Controls Unitary Products 11 1056292-XTG-A-0613 ZF180-240 Physical Data (Continued) Models Component Nominal Tonnage ZF180 ZF240 15 20 2 2 CONDENSER FAN DATA Quantity Fan diameter (Inch) 30 30 Type Prop Prop Drive type Direct Direct No. speeds 1 1 Number of motors 2 2 1.25 1.25 Motor HP each RPM 950 950 Nominal total CFM 6000 8000 BELT DRIVE EVAP FAN DATA Quantity Fan Size (Inch) Type 1 1 15 X 15 18 X 15 Centrifugal Centrifugal Motor Sheave 1VP62 1VP75 Blower Sheave BK75 BK100 Belt BX68 BX75 4.0 6.3 Motor HP each RPM 1450 1450 Frame size 184T 213T 5 - (18 x 24 x 2)1,2 12 - (12 x 24 x 2)1,2 FILTERS Quantity - Size - - 5 - (18 x 24 x 4)3 2 - (20 x 24 x 4), - 4 - (24 x 24 x 4)3 1. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 3. 2. 2 In. Pleated, Optional, MERV 7. 3. 4 In. Pleated, Optional, MERV 13. ZF180-240 Unit Limitations Unit Limitations Size (Tons) 12 Unit Voltage Applied Voltage Outdoor DB Temp Min Max Max (°F) / (°C) 180 (15) 380/415-3-50 342 457 125.6 / 52 240 (20) 380/415-3-50 342 457 125.6 / 52 Johnson Controls Unitary Products 1056292-XTG-A-0613 Capacity Performance ZF180-240 Cooling Capacities ZF180 (15 Ton) Imperial Air on Evaporator Coil CFM 3750 4500 5250 6000 6750 3750 4500 5250 6000 6750 WB (°F) Total Capacity1,2 (MBh) Total Input (kW)3 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 236.4 205.4 174.3 162.6 253.8 220.5 187.2 174.6 172.9 271.3 235.7 200.1 186.6 184.8 288.7 250.8 212.9 198.6 196.7 254.9 216.3 201.8 199.9 15.8 15.7 15.5 15.3 16.2 16.1 15.9 15.7 15.7 16.6 16.5 16.3 16.1 16.1 17.0 16.9 16.7 16.5 16.5 17.9 17.8 17.5 17.5 101.2 121.0 140.8 162.6 114.6 136.6 158.7 174.6 172.9 127.9 152.3 176.6 186.6 184.8 141.2 167.9 194.5 198.6 196.7 175.3 202.6 201.8 199.9 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 182.9 167.5 152.2 140.0 197.5 180.9 164.3 151.1 149.4 212.2 194.3 176.4 162.2 160.4 226.8 207.7 188.5 173.4 171.4 210.4 190.9 175.9 173.9 19.0 18.7 18.4 18.3 19.4 19.1 18.8 18.6 18.4 19.7 19.4 19.1 18.9 18.7 20.0 19.7 19.4 19.2 19.0 20.7 20.4 20.0 19.8 84.6 107.7 130.8 140.0 95.1 121.2 147.2 151.1 149.4 105.7 134.6 163.5 162.2 160.4 116.3 148.1 179.9 173.4 171.4 155.1 187.0 175.9 173.9 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1,2 Input (MBh) (kW)3 85 80 75 70 65 85°F 86.6 72.0 204.0 17.5 106.4 91.8 77.1 182.0 17.2 126.2 111.6 96.9 82.3 159.9 16.9 156.0 137.2 122.6 107.9 93.3 146.5 16.8 97.4 80.3 222.1 17.8 119.5 102.4 85.3 198.1 17.5 141.6 124.5 107.4 90.2 174.1 17.3 170.2 153.1 136.0 118.8 101.7 159.5 17.1 172.9 156.4 139.3 122.1 105.0 156.9 16.7 108.3 88.7 240.2 18.1 132.6 113.0 93.4 214.2 17.9 157.0 137.4 117.8 98.2 188.3 17.6 184.4 169.0 149.4 129.7 110.1 172.5 17.4 184.8 172.6 153.0 133.4 113.8 169.7 17.0 119.1 97.0 258.3 18.5 145.8 123.7 101.5 230.4 18.2 172.4 150.3 128.2 106.1 202.5 17.9 198.6 184.9 162.8 140.6 118.5 185.5 17.7 196.7 188.8 166.7 144.6 122.5 182.5 17.3 151.0 126.8 102.5 234.1 19.5 178.4 154.1 129.9 105.6 205.8 19.2 201.8 189.5 165.3 141.0 116.8 188.6 19.0 199.9 193.6 169.4 145.1 120.8 185.5 18.6 105°F 69.9 55.3 161.8 20.6 93.1 78.4 63.8 153.1 20.3 116.2 101.6 86.9 72.3 144.5 19.9 140.0 124.9 110.2 95.6 81.0 133.5 19.9 78.3 61.5 173.0 20.9 104.4 87.6 70.8 163.7 20.6 130.4 113.6 96.8 80.0 154.5 20.3 151.1 138.9 122.1 105.3 88.5 142.7 20.2 149.4 137.0 120.2 103.4 86.6 141.9 20.1 86.8 67.8 184.2 21.2 115.7 96.7 77.7 174.3 20.9 144.5 125.6 106.6 87.6 164.5 20.6 162.2 153.0 134.0 115.0 96.1 151.9 20.5 160.4 150.8 131.9 112.9 93.9 151.1 20.4 95.2 74.1 195.4 21.5 127.0 105.8 84.7 184.9 21.2 158.7 137.6 116.5 95.3 174.5 20.9 173.4 167.0 145.9 124.7 103.6 161.2 20.8 171.4 164.7 143.6 122.4 101.3 160.3 20.7 131.4 107.7 84.1 186.7 21.9 165.0 144.6 117.7 94.1 176.0 21.7 175.9 169.9 146.2 122.6 98.9 163.3 21.1 173.9 166.9 143.3 119.6 96.0 162.4 20.9 90 91.0 112.3 133.7 146.5 103.4 127.4 151.4 159.5 156.9 115.9 142.5 169.1 172.5 169.7 128.4 157.6 186.8 185.5 182.5 167.1 197.9 188.6 185.5 78.2 103.1 128.0 133.5 86.8 114.9 142.9 142.7 141.9 95.5 126.7 157.9 151.9 151.1 104.2 138.6 172.9 161.2 160.3 143.0 176.0 163.3 162.4 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 95°F 76.7 62.5 98.1 83.9 69.6 119.5 105.2 91.0 76.8 146.5 130.7 116.5 102.3 86.8 70.1 110.7 94.1 77.4 134.7 118.0 101.4 84.7 159.5 145.7 129.0 112.3 156.9 145.3 128.7 112.0 96.8 77.7 123.4 104.3 85.2 150.0 130.9 111.8 92.6 172.5 160.6 141.5 122.4 169.7 160.3 141.1 122.0 106.9 85.3 136.1 114.5 93.0 165.2 143.7 122.1 100.6 185.5 175.6 154.1 132.5 182.5 175.2 153.6 132.1 143.4 119.7 96.0 173.9 156.8 126.5 102.9 188.6 183.6 159.9 136.2 185.5 181.8 158.1 134.5 115°F 63.1 48.1 88.0 73.0 57.9 112.9 97.9 82.8 67.8 133.5 119.0 104.0 88.9 69.9 53.0 98.0 81.0 64.1 126.0 109.1 92.2 75.2 142.7 132.1 115.2 98.3 141.9 128.6 111.7 94.8 76.7 57.9 107.9 89.1 70.3 139.1 120.3 101.5 82.6 151.9 145.3 126.4 107.6 151.1 141.4 122.6 103.8 83.5 62.8 117.9 97.1 76.4 152.2 131.5 110.8 90.1 161.2 158.4 137.7 117.0 160.3 154.2 133.5 112.8 119.4 95.8 72.1 156.1 132.5 108.9 85.2 163.3 156.2 132.5 108.9 162.4 152.0 128.4 104.8 65 88.0 95.7 95.3 103.3 102.9 111.0 110.5 112.5 110.8 73.9 81.3 77.9 88.8 85.0 96.2 92.1 85.3 81.1 13 1056292-XTG-A-0613 ZF180 (15 Ton) Imperial (Continued) Air on Evaporator Coil CFM 3750 4500 5250 6000 6750 WB (°F) Total Capacity1,2 (MBh) Total Input (kW)3 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 159.3 152.7 146.1 135.2 169.6 162.6 155.7 144.0 143.6 179.9 172.6 165.2 152.9 152.4 190.2 182.5 174.8 161.8 161.2 184.0 182.2 163.7 163.2 21.1 20.8 20.4 20.4 21.4 21.1 20.8 20.7 20.6 21.7 21.4 21.1 21.0 20.9 22.0 21.7 21.4 21.3 21.2 22.3 22.4 21.4 21.3 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1,2 Input (MBh) (kW)3 90 85 80 75 70 65 118.4°F 75.0 60.8 45.6 140.7 22.1 101.5 86.3 71.1 56.0 138.7 21.8 127.0 111.8 96.6 81.5 65.7 136.7 21.4 131.3 131.3 117.0 101.8 86.7 71.5 126.9 21.4 84.0 67.0 50.1 148.4 22.4 112.8 95.8 78.8 61.8 146.5 22.1 141.5 124.5 107.6 90.6 73.6 144.6 21.8 139.8 139.8 129.8 112.9 95.9 78.9 134.3 21.7 139.4 139.4 125.8 108.8 91.9 74.9 134.4 21.7 93.0 73.3 54.5 156.2 22.7 124.1 105.3 86.5 67.7 154.4 22.4 156.0 137.3 118.5 99.7 80.9 152.5 22.1 148.4 148.4 142.5 123.9 105.1 86.3 141.7 22.0 148.0 148.0 138.2 119.4 100.7 81.9 141.8 22.0 102.0 79.5 59.0 163.9 23.0 135.3 114.8 94.2 73.6 162.2 22.7 168.7 150.0 129.4 108.8 88.3 160.4 22.4 157.0 157.0 155.2 134.9 114.3 93.7 149.0 22.3 156.5 156.5 150.6 130.1 109.5 88.9 149.2 22.3 138.9 115.3 91.7 68.1 163.0 23.0 170.9 153.1 128.4 105.9 82.2 161.1 22.9 159.0 159.0 151.5 127.9 104.3 80.6 150.6 22.1 158.5 158.5 147.0 123.3 99.7 76.1 150.9 22.1 90 69.0 98.4 125.1 126.9 78.5 108.6 138.7 134.3 134.4 88.1 118.8 152.4 141.7 141.8 97.7 129.1 160.4 149.0 149.2 131.0 161.1 150.6 150.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 56.3 40.9 83.0 67.5 52.1 109.7 94.2 78.8 61.7 126.9 113.1 97.7 82.3 61.5 44.4 91.6 74.5 57.5 121.7 104.6 87.6 70.5 134.3 125.4 108.3 91.2 134.4 120.3 103.2 86.2 66.6 48.0 100.2 81.5 62.8 133.7 115.0 96.3 79.2 141.7 137.6 118.9 100.2 141.8 132.0 113.3 94.6 71.8 51.5 108.8 88.5 68.2 145.7 125.4 105.1 84.8 149.0 149.0 129.5 109.2 149.2 143.7 123.4 103.1 107.4 83.8 60.2 147.2 120.4 100.0 76.4 150.6 142.4 118.8 95.2 150.9 137.1 113.5 89.9 65 66.8 74.2 69.1 81.5 76.0 88.9 82.8 71.6 66.3 1. These capacities are gross ratings. For net capacity, deduct air blower motor heat, MBh = 3.415 x kW. 2. Capacity ratings are based on 80°F (26.7°C) Entering Air Dry Bulb Temperature. 3. These ratings are total input kW, thus include the two condenser fan motors, compressor motors, and the supply air blower motor at 0.40" WC. 14 Johnson Controls Unitary Products 1056292-XTG-A-0613 ZF180 (15 Ton) Metric Air on Evaporator Coil M3/sec 1.77 2.12 2.48 2.83 3.19 1.77 2.12 2.48 2.83 3.19 WB (°C) Total Capacity1,2 (kW) Total Input (kW)3 32 25 22 19 17 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 69.3 60.2 51.1 47.6 74.4 64.6 54.8 51.1 50.7 79.5 69.1 58.6 54.7 54.2 84.6 73.5 62.4 58.2 57.6 74.7 63.4 59.1 58.6 15.8 15.7 15.5 15.3 16.2 16.1 15.9 15.7 15.7 16.6 16.5 16.3 16.1 16.1 17.0 16.9 16.7 16.5 16.5 17.9 17.8 17.5 17.5 29.7 35.5 41.3 47.6 33.6 40.0 46.5 51.1 50.7 37.5 44.6 51.8 54.7 54.2 41.4 49.2 57.0 58.2 57.6 51.4 59.4 59.1 58.6 25 22 19 17 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 53.6 49.1 44.6 41.0 57.9 53.0 48.1 44.3 43.8 62.2 56.9 51.7 47.5 47.0 66.5 60.8 55.2 50.8 50.2 61.7 55.9 51.5 51.0 19.0 18.7 18.4 18.3 19.4 19.1 18.8 18.6 18.4 19.7 19.4 19.1 18.9 18.7 20.0 19.7 19.4 19.2 19.0 20.7 20.4 20.0 19.8 24.8 31.6 38.3 41.0 27.9 35.5 43.1 44.3 43.8 31.0 39.4 47.9 47.5 47.0 34.1 43.4 52.7 50.8 50.2 45.4 54.8 51.5 51.0 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°C) Capacity1,2 Input (MBh) (kW)3 29 27 24 21 18 29.4°C 25.4 21.1 59.8 17.5 31.2 26.9 22.6 53.3 17.2 37.0 32.7 28.4 24.1 46.9 16.9 45.7 40.2 35.9 31.6 27.3 42.9 16.8 28.5 23.5 65.1 17.8 35.0 30.0 25.0 58.0 17.5 41.5 36.5 31.5 26.4 51.0 17.3 49.9 44.9 39.8 34.8 29.8 46.7 17.1 50.7 45.8 40.8 35.8 30.8 46.0 16.7 31.7 26.0 70.4 18.1 38.9 33.1 27.4 62.8 17.9 46.0 40.3 34.5 28.8 55.2 17.6 54.0 49.5 43.8 38.0 32.3 50.6 17.4 54.2 50.6 44.8 39.1 33.3 49.7 17.0 34.9 28.4 75.7 18.5 42.7 36.2 29.8 67.5 18.2 50.5 44.0 37.6 31.1 59.3 17.9 58.2 54.2 47.7 41.2 34.7 54.4 17.7 57.6 55.3 48.8 42.4 35.9 53.5 17.3 44.3 37.1 30.0 68.6 19.5 52.3 45.2 38.1 30.9 60.3 19.2 59.1 55.5 48.4 41.3 34.2 55.2 19.0 58.6 56.7 49.6 42.5 35.4 54.3 18.6 40.6°C 20.5 16.2 47.4 20.6 27.3 23.0 18.7 44.9 20.3 34.0 29.8 25.5 21.2 42.3 19.9 41.0 36.6 32.3 28.0 23.7 39.1 19.9 23.0 18.0 50.7 20.9 30.6 25.7 20.7 48.0 20.6 38.2 33.3 28.4 23.4 45.3 20.3 44.3 40.7 35.8 30.9 25.9 41.8 20.2 43.8 40.1 35.2 30.3 25.4 41.6 20.1 25.4 19.9 54.0 21.2 33.9 28.3 22.8 51.1 20.9 42.4 36.8 31.2 25.7 48.2 20.6 47.5 44.8 39.3 33.7 28.1 44.5 20.5 47.0 44.2 38.6 33.1 27.5 44.3 20.4 27.9 21.7 57.2 21.5 37.2 31.0 24.8 54.2 21.2 46.5 40.3 34.1 27.9 51.1 20.9 50.8 48.9 42.7 36.5 30.4 47.2 20.8 50.2 48.3 42.1 35.9 29.7 47.0 20.7 38.5 31.6 24.6 54.7 21.9 48.3 42.4 34.5 27.6 51.6 21.7 51.5 49.8 42.8 35.9 29.0 47.8 21.1 51.0 48.9 42.0 35.0 28.1 47.6 20.9 32 26.6 32.9 39.2 42.9 30.3 37.3 44.4 46.7 46.0 34.0 41.8 49.5 50.6 49.7 37.6 46.2 54.7 54.4 53.5 49.0 58.0 55.2 54.3 22.9 30.2 37.5 39.1 25.4 33.7 41.9 41.8 41.6 28.0 37.1 46.3 44.5 44.3 30.5 40.6 50.7 47.2 47.0 41.9 51.6 47.8 47.6 Sensible Capacity (MBh) Return Dry Bulb (°C) 29 27 24 21 35°C 22.5 18.3 28.7 24.6 20.4 35.0 30.8 26.7 22.5 42.9 38.3 34.1 30.0 25.4 20.5 32.4 27.6 22.7 39.5 34.6 29.7 24.8 46.7 42.7 37.8 32.9 46.0 42.6 37.7 32.8 28.4 22.8 36.2 30.6 25.0 43.9 38.3 32.7 27.1 50.6 47.1 41.5 35.9 49.7 47.0 41.4 35.8 31.3 25.0 39.9 33.5 27.2 48.4 42.1 35.8 29.5 54.4 51.5 45.1 38.8 53.5 51.3 45.0 38.7 42.0 35.1 28.1 51.0 45.9 37.1 30.1 55.2 53.8 46.9 39.9 54.3 53.3 46.3 39.4 46.1°C 18.5 14.1 25.8 21.4 17.0 33.1 28.7 24.3 19.9 39.1 34.9 30.5 26.1 20.5 15.5 28.7 23.7 18.8 36.9 32.0 27.0 22.0 41.8 38.7 33.8 28.8 41.6 37.7 32.7 27.8 22.5 17.0 31.6 26.1 20.6 40.8 35.2 29.7 24.2 44.5 42.6 37.0 31.5 44.3 41.4 35.9 30.4 24.5 18.4 34.5 28.5 22.4 44.6 38.5 32.5 26.4 47.2 46.4 40.3 34.3 47.0 45.2 39.1 33.0 35.0 28.1 21.1 45.7 38.8 31.9 25.0 47.8 45.8 38.8 31.9 47.6 44.5 37.6 30.7 18 25.8 28.0 27.9 30.3 30.2 32.5 32.4 33.0 32.5 21.7 23.8 22.8 26.0 24.9 28.2 27.0 25.0 23.8 15 1056292-XTG-A-0613 ZF180 (15 Ton) Metric Air on Evaporator Coil M3/sec 1.77 2.12 2.48 2.83 3.19 WB (°C) Total Capacity1,2 (kW) Total Input (kW)3 32 25 22 19 17 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 46.7 44.7 42.8 39.6 49.7 47.6 45.6 42.2 42.1 52.7 50.6 48.4 44.8 44.7 55.7 53.5 51.2 47.4 47.2 53.9 53.4 48.0 47.8 21.1 20.8 20.4 20.4 21.4 21.1 20.8 20.7 20.6 21.7 21.4 21.1 21.0 20.9 22.0 21.7 21.4 21.3 21.2 22.3 22.4 21.4 21.3 22.0 29.7 37.2 38.5 24.6 33.0 41.5 41.0 40.8 27.3 36.3 45.7 43.5 43.4 29.9 39.7 49.4 46.0 45.9 40.7 50.1 46.6 46.4 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°C) Capacity1,2 Input (MBh) (kW)3 29 27 24 21 18 48°C 17.8 13.4 41.2 22.1 25.3 20.8 16.4 40.6 21.8 32.8 28.3 23.9 19.3 40.1 21.4 38.5 34.3 29.8 25.4 20.9 37.2 21.4 19.6 14.7 43.5 22.4 28.1 23.1 18.1 42.9 22.1 36.5 31.5 26.5 21.6 42.4 21.8 41.0 38.0 33.1 28.1 23.1 39.3 21.7 40.8 36.9 31.9 26.9 21.9 39.4 21.7 21.5 16.0 45.8 22.7 30.8 25.3 19.8 45.2 22.4 40.2 34.7 29.2 23.7 44.7 22.1 43.5 41.8 36.3 30.8 25.3 41.5 22.0 43.4 40.5 35.0 29.5 24.0 41.6 22.0 23.3 17.3 48.0 23.0 33.6 27.6 21.6 47.5 22.7 43.9 37.9 31.9 25.9 47.0 22.4 46.0 45.5 39.5 33.5 27.5 43.7 22.3 45.9 44.1 38.1 32.1 26.1 43.7 22.3 33.8 26.9 19.9 47.8 23.0 44.9 37.6 31.0 24.1 47.2 22.9 46.6 44.4 37.5 30.5 23.6 44.1 22.1 46.4 43.1 36.1 29.2 22.3 44.2 22.1 32 20.2 28.8 36.7 37.2 23.0 31.8 40.6 39.3 39.4 25.8 34.8 44.6 41.5 41.6 28.6 37.8 47.0 43.7 43.7 38.4 47.2 44.1 44.2 Sensible Capacity (MBh) Return Dry Bulb (°C) 29 27 24 21 51.7°C 16.5 12.0 24.3 19.8 15.3 32.1 27.6 23.1 18.1 37.2 33.2 28.6 24.1 18.0 13.0 26.8 21.8 16.8 35.6 30.7 25.7 20.7 39.3 36.7 31.7 26.7 39.4 35.2 30.2 25.3 19.5 14.1 29.3 23.9 18.4 39.2 33.7 28.2 23.2 41.5 40.3 34.8 29.4 41.6 38.7 33.2 27.7 21.0 15.1 31.9 25.9 20.0 42.7 36.7 30.8 24.8 43.7 43.7 37.9 32.0 43.7 42.1 36.2 30.2 31.5 24.6 17.6 43.1 35.3 29.3 22.4 44.1 41.7 34.8 27.9 44.2 40.2 33.3 26.4 18 19.6 21.7 20.3 23.9 22.3 26.0 24.3 21.0 19.4 1. These capacities are gross ratings. For net capacity, deduct air blower motor heat, MBh = 3.415 x kW. 2. Capacity ratings are based on 80°F (26.7°C) Entering Air Dry Bulb Temperature. 3. These ratings are total input kW, thus include the two condenser fan motors, compressor motors, and the supply air blower motor at 0.40" WC. 16 Johnson Controls Unitary Products 1056292-XTG-A-0613 ZF240 (20 Ton) Imperial Air on Evaporator Coil CFM 5000 6000 7000 8000 8800 5000 6000 7000 8000 8800 WB (°F) Total Capacity1,2 (kW) Total Input (kW)3 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 241.7 236.0 230.2 216.8 254.5 248.4 242.3 228.2 219.9 267.2 260.9 254.5 239.7 230.9 280.0 273.3 266.6 251.1 241.9 289.0 281.5 265.5 255.8 20.5 20.2 20.0 19.6 21.2 20.9 20.6 20.3 20.2 21.8 21.6 21.3 20.9 20.8 22.5 22.2 22.0 21.6 21.4 23.7 23.0 22.4 22.0 114.0 153.9 193.7 216.8 126.1 169.6 213.2 228.2 219.9 138.2 185.4 232.6 239.7 230.9 150.4 201.2 252.1 251.1 241.9 223.2 274.7 265.5 255.8 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 209.3 204.3 199.3 184.0 223.3 218.0 212.7 196.4 193.7 237.4 231.7 226.0 208.7 205.9 251.4 245.4 239.4 221.0 218.1 252.4 243.7 224.6 221.6 24.3 24.0 23.7 23.3 25.0 24.7 24.3 24.0 24.0 25.7 25.4 25.0 24.7 24.8 26.4 26.0 25.7 25.5 25.5 27.2 26.8 26.1 26.0 95.9 137.8 179.7 184.0 111.8 154.8 197.9 196.4 193.7 127.7 171.9 216.1 208.7 205.9 143.6 189.0 234.3 221.0 218.1 204.4 240.7 224.6 221.6 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1,2 Input (MBh) (kW)3 85 80 75 70 65 85°F 93.5 73.0 221.4 22.7 133.3 112.8 92.3 217.3 22.2 173.2 152.6 132.1 111.6 213.1 21.8 214.4 186.2 165.7 145.2 124.7 193.7 21.5 102.9 79.7 237.5 23.4 146.4 123.2 100.0 233.0 22.9 189.9 166.7 143.5 120.3 228.5 22.4 226.6 203.4 180.2 157.0 133.8 207.7 22.1 219.9 206.9 183.7 160.5 137.3 203.4 22.0 112.3 86.4 253.5 24.1 159.5 133.6 107.7 248.7 23.6 206.7 180.8 154.9 129.0 244.0 23.1 238.9 220.6 194.7 168.8 142.9 221.8 22.8 230.9 224.4 198.5 172.6 146.7 217.1 22.8 121.8 93.2 269.5 24.7 172.6 144.0 115.4 264.5 24.2 223.5 194.9 166.3 137.7 259.4 23.7 251.1 237.8 209.2 180.6 152.0 235.8 23.4 241.9 241.9 213.3 184.7 156.1 230.9 23.6 191.0 158.8 126.5 269.4 25.7 247.0 214.8 182.6 150.4 264.2 25.0 265.5 258.9 226.7 194.5 162.2 240.2 24.3 255.8 255.8 223.6 191.4 159.1 235.2 24.2 105°F 79.0 58.8 197.1 25.9 117.6 97.5 77.3 191.3 25.8 156.3 136.1 116.0 95.8 185.4 25.6 184.0 161.3 141.2 121.0 100.9 174.3 25.2 88.8 65.8 209.2 26.6 131.8 108.8 85.8 203.0 26.4 174.9 151.9 128.8 105.8 196.8 26.3 196.4 180.3 157.3 134.3 111.3 185.0 25.9 193.7 180.2 157.1 134.1 111.1 184.1 25.9 98.6 72.7 221.2 27.3 146.0 120.1 94.3 214.7 27.1 193.5 167.6 141.7 115.8 208.1 26.9 208.7 199.3 173.4 147.5 121.6 195.6 26.7 205.9 199.1 173.2 147.4 121.5 194.7 26.7 108.4 79.6 233.3 28.0 160.2 131.5 102.7 226.4 27.8 212.0 183.3 154.6 125.8 219.5 27.6 221.0 218.2 189.5 160.8 132.0 206.3 27.5 218.1 218.1 189.3 160.6 131.8 205.3 27.5 171.9 139.4 106.8 235.4 28.7 228.0 196.3 163.8 131.3 223.2 28.6 224.6 223.2 190.7 158.2 125.7 209.0 27.9 221.6 221.6 189.1 156.6 124.1 207.9 27.9 90 105.3 144.4 183.6 193.7 118.2 161.8 205.5 207.7 203.4 131.1 179.2 227.3 221.8 217.1 144.0 196.6 249.2 235.8 230.9 216.9 259.2 240.2 235.2 86.5 131.1 175.7 174.3 105.4 147.9 190.3 185.0 184.1 124.3 164.6 204.9 195.6 194.7 143.2 181.3 219.5 206.3 205.3 191.8 222.3 209.0 207.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 95°F 84.8 64.4 124.0 103.6 83.2 163.2 142.8 122.3 101.9 193.7 172.1 151.7 131.3 95.0 71.8 138.6 115.4 92.2 182.3 159.1 135.9 112.7 207.7 192.2 169.0 145.9 203.4 190.9 167.7 144.5 105.1 79.1 153.2 127.3 101.3 201.3 175.4 149.4 123.5 221.8 212.4 186.4 160.4 217.1 210.9 184.9 159.0 115.2 86.5 167.8 139.1 110.4 220.4 191.7 163.0 134.3 235.8 232.5 203.8 175.0 230.9 230.9 202.1 173.4 184.3 151.7 119.0 241.6 209.0 176.4 143.8 240.2 238.6 205.9 173.3 235.2 235.2 202.6 170.0 115°F 73.1 53.3 111.3 91.4 71.5 149.4 129.5 109.6 89.7 174.3 150.6 130.7 110.8 82.6 59.8 125.0 102.2 79.4 167.5 144.6 121.8 99.0 185.0 168.4 145.5 122.7 184.1 169.4 146.6 123.7 92.0 66.2 138.8 113.0 87.2 185.6 159.8 134.0 108.2 195.6 186.2 160.4 134.6 194.7 187.3 161.5 135.7 101.5 72.7 152.6 123.8 95.1 203.7 174.9 146.1 117.4 206.3 204.0 175.3 146.5 205.3 205.3 176.5 147.7 159.4 127.0 94.7 214.4 183.6 151.2 118.8 209.0 207.8 175.5 143.1 207.9 207.9 175.6 143.2 65 110.8 122.7 121.3 134.5 133.0 146.3 144.7 140.7 137.4 90.9 99.8 100.9 108.8 109.9 117.7 119.0 110.7 110.8 17 1056292-XTG-A-0613 ZF240 (20 Ton) Imperial (Continued) Air on Evaporator Coil CFM 5000 6000 7000 8000 8800 WB (°F) Total Capacity1,2 (kW) Total Input (kW)3 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 192.2 186.9 180.7 171.0 204.4 197.9 191.4 181.1 180.1 216.6 208.9 202.0 191.2 190.8 228.8 219.9 211.0 201.3 200.2 229.6 221.5 203.7 202.2 26.4 26.4 26.2 25.8 27.2 27.0 26.9 26.6 26.6 28.0 27.7 27.6 27.4 27.4 28.8 28.6 28.4 28.2 28.2 29.4 28.9 28.7 28.6 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1,2 Input (MBh) (kW)3 90 85 80 75 70 65 118.4°F 82.6 71.0 51.4 182.6 27.2 128.9 109.1 89.3 69.5 178.3 27.5 174.3 147.0 127.2 107.5 86.8 171.6 27.5 171.0 171.0 146.9 127.1 107.3 87.5 164.6 27.0 103.9 80.5 57.7 195.0 28.3 145.5 122.7 99.9 77.2 188.0 28.2 187.1 165.0 142.2 119.4 96.6 180.9 28.2 181.1 181.1 164.3 141.5 118.8 96.0 173.6 27.9 180.1 180.1 165.7 143.0 120.2 97.4 172.4 27.8 125.2 89.9 64.1 207.5 29.3 162.1 136.4 110.6 84.8 197.6 28.9 199.9 182.9 157.1 131.3 105.6 190.2 28.9 191.2 191.2 181.7 156.0 130.2 104.4 182.6 28.7 190.8 190.8 183.0 157.6 131.8 106.0 183.4 28.7 146.5 99.4 70.4 220.0 30.3 178.8 150.0 121.2 92.5 207.3 30.1 211.0 200.6 172.0 143.3 114.5 194.7 29.9 201.3 201.3 199.2 170.4 141.6 112.9 191.5 29.6 200.2 200.2 200.2 172.1 143.4 114.6 190.3 29.5 187.6 155.2 122.9 90.5 218.4 30.9 215.7 209.8 179.2 146.9 114.5 202.8 30.8 203.7 203.7 202.6 170.3 137.9 105.6 193.4 30.1 202.2 202.2 202.2 171.0 138.6 106.2 191.0 30.1 90 75.0 124.5 171.6 164.6 100.9 140.9 180.9 173.6 172.4 126.8 157.3 190.2 182.6 183.4 152.8 173.7 194.7 191.5 190.3 179.3 202.8 193.4 191.0 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 67.0 47.7 104.9 85.3 65.7 142.5 122.9 103.3 81.2 164.6 139.8 120.2 100.5 76.4 53.7 118.2 95.6 72.9 160.1 137.4 114.8 92.1 173.6 156.4 133.8 111.1 172.4 158.6 136.0 113.3 85.8 59.8 131.6 105.9 80.2 177.7 152.0 126.2 103.0 182.6 173.1 147.4 121.7 183.4 175.5 149.8 124.1 95.2 65.9 145.0 116.2 87.4 194.7 166.5 137.7 109.0 191.5 189.8 161.0 132.2 190.3 190.3 163.7 134.9 147.0 114.7 82.5 200.8 170.8 138.6 106.3 193.4 192.5 160.2 127.9 191.0 191.0 162.0 129.8 65 80.9 88.4 90.7 95.9 98.4 103.5 106.1 95.7 97.5 1. These capacities are gross ratings. For net capacity, deduct air blower motor heat, MBh = 3.415 x kW. 2. Capacity ratings are based on 80°F (26.7°C) Entering Air Dry Bulb Temperature. 3. These ratings are total input kW, thus include the two condenser fan motors, compressor motors, and the supply air blower motor at 0.40" WC. 18 Johnson Controls Unitary Products 1056292-XTG-A-0613 ZF240 (20 Ton) Metric Air on Evaporator Coil 3 M /sec 2.36 2.83 3.30 3.78 4.15 2.36 2.83 3.30 3.78 4.15 WB (°C) Total Capacity1,2 (kW) Total Input (kW)3 32 25 22 19 17 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 70.8 69.1 67.4 63.5 74.6 72.8 71.0 66.9 64.4 78.3 76.4 74.6 70.2 67.6 82.0 80.1 78.1 73.6 70.9 84.7 82.5 77.8 74.9 20.5 20.2 20.0 19.6 21.2 20.9 20.6 20.3 20.2 21.8 21.6 21.3 20.9 20.8 22.5 22.2 22.0 21.6 21.4 23.7 23.0 22.4 22.0 33.4 45.1 56.8 63.5 37.0 49.7 62.5 66.9 64.4 40.5 54.3 68.2 70.2 67.6 44.1 59.0 73.9 73.6 70.9 65.4 80.5 77.8 74.9 25 22 19 17 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 61.3 59.9 58.4 53.9 65.4 63.9 62.3 57.5 56.8 69.5 67.9 66.2 61.1 60.3 73.7 71.9 70.2 64.8 63.9 74.0 71.4 65.8 64.9 24.3 24.0 23.7 23.3 25.0 24.7 24.3 24.0 24.0 25.7 25.4 25.0 24.7 24.8 26.4 26.0 25.7 25.5 25.5 27.2 26.8 26.1 26.0 28.1 40.4 52.6 53.9 32.8 45.4 58.0 57.5 56.8 37.4 50.4 63.3 61.1 60.3 42.1 55.4 68.7 64.8 63.9 59.9 70.5 65.8 64.9 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°C) Capacity1,2 Input (MBh) (kW)3 29 27 24 21 18 29.4°C 27.4 21.4 64.9 22.7 39.1 33.1 27.0 63.7 22.2 50.7 44.7 38.7 32.7 62.4 21.8 62.8 54.6 48.6 42.5 36.5 56.8 21.5 30.2 23.3 69.6 23.4 42.9 36.1 29.3 68.3 22.9 55.7 48.9 42.0 35.2 67.0 22.4 66.4 59.6 52.8 46.0 39.2 60.9 22.1 64.4 60.6 53.8 47.0 40.2 59.6 22.0 32.9 25.3 74.3 24.1 46.7 39.1 31.6 72.9 23.6 60.6 53.0 45.4 37.8 71.5 23.1 70.0 64.6 57.0 49.5 41.9 65.0 22.8 67.6 65.7 58.2 50.6 43.0 63.6 22.8 35.7 27.3 79.0 24.7 50.6 42.2 33.8 77.5 24.2 65.5 57.1 48.7 40.3 76.0 23.7 73.6 69.7 61.3 52.9 44.5 69.1 23.4 70.9 70.9 62.5 54.1 45.7 67.6 23.6 56.0 46.5 37.1 78.9 25.7 72.4 62.9 53.5 44.1 77.4 25.0 77.8 75.9 66.4 57.0 47.5 70.4 24.3 74.9 74.9 65.5 56.1 46.6 68.9 24.2 40.6°C 23.1 17.2 57.8 25.9 34.5 28.6 22.7 56.0 25.8 45.8 39.9 34.0 28.1 54.3 25.6 53.9 47.3 41.4 35.5 29.6 51.1 25.2 26.0 19.3 61.3 26.6 38.6 31.9 25.1 59.5 26.4 51.2 44.5 37.7 31.0 57.7 26.3 57.5 52.8 46.1 39.3 32.6 54.2 25.9 56.8 52.8 46.0 39.3 32.6 53.9 25.9 28.9 21.3 64.8 27.3 42.8 35.2 27.6 62.9 27.1 56.7 49.1 41.5 33.9 61.0 26.9 61.1 58.4 50.8 43.2 35.6 57.3 26.7 60.3 58.3 50.8 43.2 35.6 57.0 26.7 31.8 23.3 68.4 28.0 46.9 38.5 30.1 66.3 27.8 62.1 53.7 45.3 36.9 64.3 27.6 64.8 63.9 55.5 47.1 38.7 60.4 27.5 63.9 63.9 55.5 47.0 38.6 60.1 27.5 50.4 40.8 31.3 69.0 28.7 66.8 57.5 48.0 38.5 65.4 28.6 65.8 65.4 55.9 46.4 36.8 61.2 27.9 64.9 64.9 55.4 45.9 36.4 60.9 27.9 32 30.8 42.3 53.8 56.8 34.6 47.4 60.2 60.9 59.6 38.4 52.5 66.6 65.0 63.6 42.2 57.6 73.0 69.1 67.6 63.5 75.9 70.4 68.9 25.4 38.4 51.5 51.1 30.9 43.3 55.8 54.2 53.9 36.4 48.2 60.0 57.3 57.0 42.0 53.1 64.3 60.4 60.1 56.2 65.1 61.2 60.9 Sensible Capacity (MBh) Return Dry Bulb (°C) 29 27 24 21 35°C 24.9 18.9 36.3 30.4 24.4 47.8 41.8 35.8 29.9 56.8 50.4 44.4 38.5 27.8 21.0 40.6 33.8 27.0 53.4 46.6 39.8 33.0 60.9 56.3 49.5 42.7 59.6 55.9 49.1 42.3 30.8 23.2 44.9 37.3 29.7 59.0 51.4 43.8 36.2 65.0 62.2 54.6 47.0 63.6 61.8 54.2 46.6 33.8 25.3 49.2 40.8 32.3 64.6 56.2 47.8 39.3 69.1 68.1 59.7 51.3 67.6 67.6 59.2 50.8 54.0 44.4 34.9 70.8 61.2 51.7 42.1 70.4 69.9 60.3 50.8 68.9 68.9 59.4 49.8 46.1°C 21.4 15.6 32.6 26.8 20.9 43.8 37.9 32.1 26.3 51.1 44.1 38.3 32.5 24.2 17.5 36.6 29.9 23.2 49.1 42.4 35.7 29.0 54.2 49.3 42.6 35.9 53.9 49.6 42.9 36.2 27.0 19.4 40.7 33.1 25.6 54.4 46.8 39.3 31.7 57.3 54.6 47.0 39.4 57.0 54.9 47.3 39.8 29.7 21.3 44.7 36.3 27.9 59.7 51.2 42.8 34.4 60.4 59.8 51.3 42.9 60.1 60.1 51.7 43.3 46.7 37.2 27.7 62.8 53.8 44.3 34.8 61.2 60.9 51.4 41.9 60.9 60.9 51.4 41.9 18 32.5 35.9 35.6 39.4 39.0 42.9 42.4 41.2 40.2 26.6 29.3 29.6 31.9 32.2 34.5 34.9 32.4 32.5 19 1056292-XTG-A-0613 ZF240 (20 Ton) Metric (Continued) Air on Evaporator Coil M3/sec 2.36 2.83 3.30 3.78 4.15 WB (°C) Total Capacity1,2 (kW) Total Input (kW)3 32 25 22 19 17 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 56.3 54.8 53.0 50.1 59.9 58.0 56.1 53.1 52.8 63.5 61.2 59.2 56.0 55.9 67.0 64.4 61.8 59.0 58.6 67.3 64.9 59.7 59.2 26.4 26.4 26.2 25.8 27.2 27.0 26.9 26.6 26.6 28.0 27.7 27.6 27.4 27.4 28.8 28.6 28.4 28.2 28.2 29.4 28.9 28.7 28.6 24.2 37.8 51.1 50.1 30.4 42.6 54.8 53.1 52.8 36.7 47.5 58.6 56.0 55.9 42.9 52.4 61.8 59.0 58.6 55.0 63.2 59.7 59.2 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°C) Capacity1,2 Input (MBh) (kW)3 29 27 24 21 18 48°C 20.8 15.0 53.5 27.2 32.0 26.2 20.4 52.2 27.5 43.1 37.3 31.5 25.4 50.3 27.5 50.1 43.0 37.2 31.4 25.6 48.2 27.0 23.6 16.9 57.1 28.3 36.0 29.3 22.6 55.1 28.2 48.3 41.7 35.0 28.3 53.0 28.2 53.1 48.1 41.5 34.8 28.1 50.9 27.9 52.8 48.6 41.9 35.2 28.5 50.5 27.8 26.3 18.8 60.8 29.3 40.0 32.4 24.8 57.9 28.9 53.6 46.0 38.5 30.9 55.7 28.9 56.0 53.3 45.7 38.1 30.6 53.5 28.7 55.9 53.6 46.2 38.6 31.1 53.7 28.7 29.1 20.6 64.4 30.3 43.9 35.5 27.1 60.7 30.1 58.8 50.4 42.0 33.6 57.0 29.9 59.0 58.4 49.9 41.5 33.1 56.1 29.6 58.6 58.6 50.4 42.0 33.6 55.7 29.5 45.5 36.0 26.5 64.0 30.9 61.5 52.5 43.0 33.6 59.4 30.8 59.7 59.4 49.9 40.4 30.9 56.7 30.1 59.2 59.2 50.1 40.6 31.1 56.0 30.1 32 22.0 36.5 50.3 48.2 29.6 41.3 53.0 50.9 50.5 37.2 46.1 55.7 53.5 53.7 44.8 50.9 57.0 56.1 55.7 52.5 59.4 56.7 56.0 Sensible Capacity (MBh) Return Dry Bulb (°C) 29 27 24 21 51.7°C 19.6 14.0 30.7 25.0 19.2 41.7 36.0 30.3 23.8 48.2 41.0 35.2 29.5 22.4 15.7 34.6 28.0 21.4 46.9 40.3 33.6 27.0 50.9 45.8 39.2 32.6 50.5 46.5 39.8 33.2 25.1 17.5 38.6 31.0 23.5 52.1 44.5 37.0 30.2 53.5 50.7 43.2 35.6 53.7 51.4 43.9 36.4 27.9 19.3 42.5 34.0 25.6 57.0 48.8 40.4 31.9 56.1 55.6 47.2 38.7 55.7 55.7 48.0 39.5 43.1 33.6 24.2 58.8 50.1 40.6 31.1 56.7 56.4 46.9 37.5 56.0 56.0 47.5 38.0 18 23.7 25.9 26.6 28.1 28.8 30.3 31.1 28.0 28.6 1. These capacities are gross ratings. For net capacity, deduct air blower motor heat, MBh = 3.415 x kW. 2. Capacity ratings are based on 80°F (26.7°C) Entering Air Dry Bulb Temperature. 3. These ratings are total input kW, thus include the two condenser fan motors, compressor motors, and the supply air blower motor at 0.40" WC. 20 Johnson Controls Unitary Products 1056292-XTG-A-0613 Airflow Performance ZF180-240 Side Duct Application ZF180 (15 Ton) Side Duct Imperial Air Flow (CFM) 4400 4800 5200 5600 6000 6400 6800 7200 Available External Static Pressure - IWG1 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 760 786 815 845 877 911 946 982 High Static 4.0 HP & Field Supplied Drive 1.56 798 1.90 835 2.20 878 2.47 1.93 824 2.27 861 2.57 904 2.84 2.34 853 2.68 890 2.98 933 3.25 2.79 883 3.13 920 3.43 963 3.70 3.28 915 3.62 952 3.92 995 4.19 3.81 949 4.15 986 4.45 1029 4.72 4.38 984 4.72 1021 5.02 1064 5.29 4.98 1020 5.32 1057 5.62 - High Static 4.0 HP & OEM Supplied Drive 950 2.81 1014 3.11 1069 3.38 1115 3.61 976 3.18 1040 3.48 1095 3.75 1142 3.98 1005 3.59 1068 3.89 1123 4.16 1170 4.39 1035 4.04 1099 4.34 1154 4.61 1200 4.84 1067 4.53 1131 4.83 1186 5.10 1232 5.33 1101 5.06 1164 5.36 1219 5.63 Field Supplied Motor & Drive 1154 1180 1208 1239 1271 - 3.81 4.18 4.59 5.04 5.53 - 1184 1210 1238 1269 - 3.97 4.34 4.75 5.20 - 1205 1231 1260 1290 - 4.09 4.46 4.87 5.32 - 1218 1244 1273 1303 - 4.18 4.55 4.96 5.41 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.838. ZF180 (15 Ton) Side Duct Metric Air Flow M3/sec. 2.08 2.27 2.45 2.64 2.83 3.02 3.21 3.40 Available External Static Pressure - Pa1 100 149 199 249 299 349 399 448 498 548 598 648 RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM Kw RPM kW 760 786 815 845 877 911 946 982 High Static 4.0 HP & Field Supplied Drive 1.16 798 1.42 835 1.64 878 1.84 1.44 824 1.69 861 1.92 904 2.12 1.75 853 2.00 890 2.22 933 2.42 2.08 883 2.33 920 2.56 963 2.76 2.45 915 2.70 952 2.92 995 3.12 2.84 949 3.10 986 3.32 1029 3.52 3.27 984 3.52 1021 3.74 1064 3.94 3.71 1020 3.97 1057 4.19 - 950 976 1005 1035 1067 1101 - High Static 4.0 HP & OEM Drive 2.09 1014 2.32 1069 2.52 1115 2.37 1040 2.60 1095 2.80 1142 2.68 1068 2.90 1123 3.10 1170 3.01 1099 3.24 1154 3.44 1200 3.38 1131 3.60 1186 3.80 1232 3.77 1164 4.00 1219 4.20 Field Supplied Motor & Drive 2.69 2.97 3.27 3.61 3.97 - 1154 1180 1208 1239 1271 - 2.84 3.12 3.42 3.76 4.12 - 1184 1210 1238 1269 - 2.96 3.24 3.54 3.88 - 1205 1231 1260 1290 - 3.50 3.33 3.63 3.97 - 1218 1244 1273 1303 - 3.12 2.39 3.70 4.03 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. Johnson Controls Unitary Products 21 1056292-XTG-A-0613 ZF240 (20 Ton) Side Duct Imperial Air Flow (CFM) 5200 5600 6000 6400 6800 7200 7600 8000 8400 8800 9200 9600 10000 Available External Static Pressure - IWG1 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 678 697 717 740 763 789 815 844 873 904 936 969 1003 High Static 6.3 HP & Field Supplied Drive 1.35 715 1.83 751 2.28 787 2.70 823 3.09 858 3.43 892 3.74 925 1.74 733 2.22 770 2.67 806 3.09 842 3.48 876 3.82 911 4.13 944 2.17 754 2.65 790 3.10 826 3.52 862 3.90 897 4.25 931 4.55 964 2.64 776 3.11 812 3.57 848 3.99 884 4.37 919 4.72 953 5.02 986 3.15 800 3.63 836 4.08 872 4.50 908 4.88 943 5.23 977 5.53 1010 3.71 825 4.18 861 4.63 898 5.05 933 5.44 968 5.79 1002 6.09 1035 4.31 852 4.79 888 5.24 924 5.66 960 6.04 995 6.39 1029 6.69 1062 4.96 880 5.44 916 5.89 952 6.31 988 6.70 1023 7.04 1057 7.34 1090 5.66 909 6.13 946 6.59 982 7.01 1018 7.39 1053 7.74 1087 8.04 1120 6.40 940 6.88 977 7.33 1013 7.75 1048 8.14 1083 8.48 1117 8.79 7.19 972 7.67 1009 8.12 1045 8.54 1080 8.93 8.03 1005 8.50 1042 8.96 8.91 Field Supplied Motor & Drive High Static 6.3 HP & OEM Drive 3.99 957 4.19 987 4.33 1015 4.38 975 4.58 1005 4.72 1034 4.81 996 5.01 1026 5.15 1054 5.28 1018 5.48 1048 5.62 1076 5.79 1042 5.99 1072 6.13 1100 6.34 1067 6.55 1097 6.69 1126 6.95 1094 7.15 1124 7.29 1152 7.60 1122 7.80 1152 7.94 1180 8.30 1151 8.50 1182 8.64 - 4.41 4.80 5.23 5.70 6.21 6.77 7.37 8.02 - 1042 1060 1081 1103 1127 1152 1179 - 4.42 4.82 5.24 5.71 6.22 6.78 7.38 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.838. ZF240 (20 Ton) Side Duct Metric Available External Static Pressure - Pa1 Air Flow 100 149 199 249 299 349 399 448 498 548 598 648 M3/sec. RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW 2.45 2.64 2.83 3.02 3.21 3.40 3.59 3.78 3.96 4.15 4.34 4.53 4.72 678 697 717 740 763 789 815 844 873 904 936 969 1003 1.01 715 1.30 733 1.62 754 1.97 776 2.35 800 2.77 825 3.21 852 3.70 880 4.22 909 4.77 940 5.36 972 5.99 1005 6.64 - High Static 6.3 HP & Field Supplied Drive 1.36 751 1.70 787 2.01 823 2.30 858 2.56 892 2.79 925 1.66 770 1.99 806 2.30 842 2.60 876 2.85 911 3.08 944 1.98 790 2.31 826 2.62 862 2.91 897 3.17 931 3.39 964 2.32 812 2.66 848 2.98 884 3.26 919 3.52 953 3.74 986 2.71 836 3.04 872 3.36 908 3.64 943 3.90 977 4.12 1010 3.12 861 3.45 898 3.77 933 4.06 968 4.32 1002 4.54 1035 3.57 888 3.91 924 4.22 960 4.50 995 4.77 1029 4.99 1062 4.06 916 4.39 952 4.71 988 5.00 1023 5.25 1057 5.47 1090 4.57 946 4.91 982 5.23 1018 5.51 1053 5.77 1087 6.00 1120 5.13 977 5.47 1013 5.78 1048 6.07 1083 6.32 1117 6.55 5.70 1009 6.06 1045 6.37 1080 6.66 6.34 1042 6.68 Field Supplied Motor & Drive High Static 6.3 HP & OEM Drive 2.98 957 3.12 987 3.23 1015 3.27 975 3.42 1005 3.52 1034 3.59 996 3.74 1026 3.84 1054 3.94 1018 4.09 1048 4.19 1076 4.32 1042 4.47 1072 4.57 1100 4.73 1067 4.88 1097 4.99 1126 5.18 1094 5.33 1124 5.44 1152 5.67 1122 8.82 1152 5.92 1180 6.19 1151 6.34 1182 6.44 1210 - 3.29 3.58 3.90 4.25 4.63 5.05 5.50 5.98 6.50 - 1042 1060 1081 1103 1127 1152 1179 1207 - 3.30 3.59 3.91 4.26 4.64 5.06 5.50 5.99 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 22 Johnson Controls Unitary Products 1056292-XTG-A-0613 ZF180-240 Bottom Duct Application ZF180 (15 Ton) Bottom Duct Imperial Air Flow (CFM) 4400 4800 5200 5600 6000 6400 6800 7200 Available External Static Pressure - IWG1 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 803 832 863 896 930 965 1002 1040 1.70 2.11 2.55 3.03 3.54 4.09 4.67 5.28 High Static 4.0 HP & Field Supplied Drive 841 2.00 877 2.28 870 2.42 906 2.69 900 2.86 936 3.14 933 3.34 969 3.62 967 3.86 1003 4.13 1002 4.41 1038 4.68 1039 4.99 1075 5.27 1077 5.60 - High Static 4.0 HP & OEM Drive 919 948 979 1011 1045 1081 1117 - 2.52 2.93 3.38 3.86 4.38 4.93 5.51 - 991 1020 1051 1084 1118 1153 - 2.84 3.25 3.70 4.19 4.70 5.25 - 1055 1084 1115 1147 1181 1217 - 3.13 3.54 3.99 4.47 4.99 5.54 - 1110 1139 1169 1202 1236 - 3.38 3.79 4.24 4.73 5.24 - Field Supplied Motor & Drive 1155 1185 1215 1248 1282 - 3.59 4.01 4.46 4.94 5.46 - 1193 1222 1253 1285 - 3.78 4.19 4.64 5.13 - 1221 1250 1281 1314 - 3.93 4.34 4.79 5.27 - 1242 1271 1301 1334 - 4.04 4.45 4.90 5.39 - 1253 1282 1313 1345 - 4.12 4.53 4.98 5.47 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.838. ZF180 (15 Ton) Bottom Duct Metric Air Flow M3/sec. 2.08 2.27 2.45 2.64 2.83 3.02 3.21 3.40 Available External Static Pressure - Pa1 100 149 199 249 299 349 399 448 498 548 598 648 RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW High Static 4.0 HP & Field Supplied Drive 803 1.27 841 1.49 877 1.70 919 1.88 832 1.57 870 1.80 906 2.01 948 2.18 863 1.90 900 2.13 936 2.34 979 2.52 896 2.26 933 2.49 969 2.70 1011 2.88 930 2.64 967 2.88 1003 3.08 1045 3.27 965 3.05 1002 3.29 1038 3.49 1081 3.68 1002 3.48 1039 3.72 1075 3.93 1117 4.11 1040 3.94 1077 4.18 - High Static 4.0 HP & OEM Drive 991 2.12 1055 2.33 1110 2.52 1020 2.42 1084 2.64 1139 2.83 1051 2.76 1115 2.98 1169 3.16 1084 3.12 1147 3.33 1202 3.53 1118 3.50 1181 3.72 1236 3.91 1153 3.91 1217 4.13 - 1155 1185 1215 1248 1282 - 2.68 2.99 3.33 3.68 4.07 - Field Supplied Motor & Drive 1193 2.82 1221 2.93 1242 3.01 1222 3.12 1250 3.24 1271 3.32 1253 3.46 1281 3.57 1301 3.65 1285 3.83 1314 3.93 1334 4.02 - 1253 1282 1313 1345 - 3.07 3.38 3.71 4.08 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. Johnson Controls Unitary Products 23 1056292-XTG-A-0613 ZF240 (20 Ton) Bottom Duct Imperial Air Flow (CFM) 5200 5600 6000 6400 6800 7200 7600 8000 8400 8800 9200 9600 10000 Available External Static Pressure - IWG1 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 711 732 754 779 804 832 860 890 921 954 987 1021 546 High Static 6.3 HP & Field Supplied Drive 1.47 747 1.92 782 2.34 818 2.73 853 1.89 768 2.33 803 2.76 839 3.15 874 2.35 790 2.79 826 3.21 862 3.61 897 2.85 814 3.29 850 3.71 886 4.11 921 3.39 840 3.84 876 4.26 912 4.65 947 3.98 868 4.43 903 4.85 939 5.24 974 4.62 896 5.06 932 5.49 967 5.88 1002 5.30 926 5.74 962 6.17 997 6.56 1032 6.02 957 6.47 993 6.89 1028 7.28 1064 6.79 989 7.24 1025 7.66 1061 8.05 1096 7.60 1023 8.05 1059 8.47 1094 8.86 8.45 1057 8.90 4.89 564 5.11 - High Static 6.3 HP & OEM Drive 3.09 887 3.42 921 3.70 953 3.94 985 4.13 1014 3.51 908 3.84 942 4.12 974 4.36 1005 4.54 1035 3.97 931 4.29 965 4.58 997 4.81 1028 5.00 1058 4.47 955 4.79 989 5.08 1021 5.31 1052 5.50 1082 5.01 981 5.34 1015 5.62 1047 5.86 1078 6.05 1108 5.60 1008 5.93 1042 6.21 1074 6.45 1105 6.64 1135 6.24 1037 6.56 1070 6.85 1103 7.09 1134 7.27 1164 6.92 1067 7.24 1100 7.53 1133 7.77 1164 7.95 1194 7.64 1098 7.97 1131 8.25 1164 8.49 1195 8.68 8.41 1130 8.74 Field Supplied Motor & Drive 4.26 4.68 5.14 5.64 6.18 6.77 7.41 8.09 - 1042 1063 1086 1110 1136 1163 1192 - 4.34 4.75 5.21 5.71 6.26 6.85 7.48 - 1068 1089 1112 1136 1162 1189 - 4.35 4.76 5.22 5.72 6.27 6.86 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.838. ZF240 (20 Ton) Bottom Duct Metric Available External Static Pressure - Pa1 Air FlowM3/ 100 149 199 249 299 349 399 498 548 598 648 448 sec. RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW 2.45 2.64 2.83 3.02 3.21 3.40 3.59 3.78 3.96 4.15 4.34 4.53 711 732 754 779 804 832 860 890 921 954 987 1021 High Static 6.3 HP & Field Supplied Drive 1.10 747 1.43 782 1.75 818 2.04 853 1.41 768 1.74 803 2.06 839 2.35 874 1.75 790 2.08 826 2.39 862 2.69 897 2.13 814 2.45 850 2.77 886 3.07 921 2.53 840 2.86 876 3.18 912 3.47 947 2.97 868 3.30 903 3.62 939 3.91 974 3.45 896 3.77 932 4.09 967 4.39 1002 3.95 926 4.28 962 4.6 997 4.89 1032 4.49 957 4.82 993 5.14 1028 5.43 1064 5.06 989 5.40 1025 5.71 1061 6.00 1096 5.67 1023 6.00 1059 6.32 1094 6.61 6.30 1057 6.64 - High Static 6.3 HP & OEM Drive 2.30 887 2.55 921 2.76 953 2.94 985 3.08 1014 2.62 908 2.86 942 3.07 974 3.25 1005 3.39 1035 2.82 931 3.20 965 3.42 997 3.59 1028 3.72 1058 3.33 955 3.57 989 3.79 1021 3.96 1052 4.10 1082 3.74 981 3.98 1015 4.19 1047 4.37 1078 4.51 1108 4.18 1008 4.42 1042 4.63 1074 4.81 1105 4.95 1135 4.65 1037 4.89 1070 5.11 1103 5.29 1134 5.42 1164 5.16 1067 5.40 1100 5.62 1133 5.79 1164 5.93 1194 5.70 1098 5.94 1131 6.15 1164 6.33 1195 6.47 6.27 1130 6.52 Field Supplied Motor & Drive 3.18 3.49 3.83 4.21 4.61 5.05 5.53 6.03 - 1042 1063 1086 1110 1136 1163 1192 - 3.24 3.54 3.89 4.26 4.67 5.11 5.58 - 1068 1089 1112 1136 1162 1189 - 3.24 3.55 3.89 4.27 4.68 5.12 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.838. 24 Johnson Controls Unitary Products 1056292-XTG-A-0613 RPM Selection Motor Blower 6 Turns Size Model HP Max BHP Sheave Sheave Open (Tons) 180 ZF 4.0 4.72 1VP62 BK75 925 (15) 240 ZF 6.3 7.13 1VP75 BK100 895 (20) * Maximum blower speed is 1400 RPM for ZF180 and 1200 RPM for ZF240 5 Turns Open 4 Turns Open 3 Turns Open 2 Turns Open 1 Turn Open Fully Closed 967 1009 1051 1093 1135 N/A 926 956 987 1018 1049 N/A Additional Static Resistance Size (Tons) Model 180 (15) ZF 240 (20) ZF CFM Cooling Only1 Economizer2 3 4500 6000 7500 6000 7500 9000 10500 12000 0.10 0.10 0.10 0.10 0.10 0.15 0.15 0.20 0.10 0.10 0.10 0.10 0.10 0.15 0.15 0.20 18 0.10 0.10 0.10 0.10 0.10 0.10 0.20 0.30 Electric Heat kW2 36 54 0.10 0.20 0.20 0.30 0.30 0.40 0.10 0.20 0.20 0.30 0.30 0.40 0.40 0.60 0.50 0.70 72 0.20 0.40 0.60 0.20 0.40 0.60 0.80 0.90 1. Add these values to the available static resistance in the respective Blower Performance Tables. 2. Deduct these values from the available external static pressure shown in the respective Blower Performance Tables. 3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. Johnson Controls Unitary Products 25 1056292-XTG-A-0613 Drive Selection 1. Determine side or bottom supply duct application. 2. Determine desired airflow 3. Calculate or measure the amount of external static pressure. 4. Using the operating point determined from steps 1, 2 & 3, locate this point on the appropriate supply air blower performance table. (Linear interpolation may be necessary.) 5. Noting the RPM and BHP from step 4, locate the appropriate motor and/or drive on the RPM selection table. 6. Review the BHP compared to the motor options available. Select the appropriate motor and/or drive. 7. Review the RPM range for the motor options available. Select the appropriate drive if multiple drives are available for the chosen motor. 8. Determine turns open to obtain the desired operation point. Example 1. 6800 CFM 2. 2.0 iwg 3. Using the supply air blower performance table below, the following data point was located: 1020 RPM & 5.92 BHP. 4. Using the RPM selection table below, Size X and Model Y is found. 5. 5.92 BHP exceeds the maximum continuous BHP rating of the 5.0 HP motor. The 7.5 HP motor is required. 6. 1020 RPM is within the range of the 7.5 HP drives. 7. Using the 7.5 HP motor and drive, 3.5 turns open will achieve 1020 RPM. Example Supply Air Blower Performance Air Flow (CFM) 6400 6800 7200 7600 Available External Static Pressure - IWG 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Standard 5 HP & Field Supplied Drive 719 2.55 742 3.02 765 3.54 790 4.11 Standard 5 HP & Drive 756 778 802 827 3.03 3.51 4.03 4.60 792 814 838 863 3.49 3.97 4.49 5.06 828 850 874 899 3.92 4.40 4.92 5.49 864 886 910 935 High Static 7.5 HP & Drive 4.32 4.79 5.32 5.88 899 921 945 970 4.67 933 5.15 955 5.67 979 6.24 1004 4.98 966 5.24 998 5.45 1028 5.46 988 5.72 1020 5.92 1050 5.98 1012 6.24 1044 6.44 1074 6.55 1037 6.81 1069 7.01 1099 5.59 6.07 6.59 7.16 1056 5.67 1083 5.68 1078 6.15 1105 6.16 1102 6.67 1129 6.68 1127 7.24 1154 7.25 7.5 HP & Field Supplied Drive Table X: RPM Selection Size (Tons) Model HP X Y 5 7.5 26 Max BHP 5.75 8.63 Motor Sheave 1VP60 1VP60 Blower Sheave BK110 BK090 6 Turns Open 730 905 5 Turns Open 765 950 4 Turns Open 800 990 3 Turns Open 835 1035 2 Turns Open 870 1075 1 Turn Open 905 1120 Fully Closed N/A N/A Johnson Controls Unitary Products 1056292-XTG-A-0613 Altitude/Temperature Correction Factors Imperial Air Temp. F 40 50 60 70 80 90 100 0 1.060 1.039 1.019 1.000 0.982 0.964 0.946 1000 1.022 1.002 0.982 0.964 0.947 0.929 0.912 2000 0.986 0.966 0.948 0.930 0.913 0.897 0.880 3000 0.950 0.931 0.913 0.896 0.880 0.864 0.848 4000 0.916 0.898 0.880 0.864 0.848 0.833 0.817 Altitude (Ft.) 5000 0.882 0.864 0.848 0.832 0.817 0.802 0.787 6000 0.849 0.832 0.816 0.801 0.787 0.772 0.758 7000 0.818 0.802 0.787 0.772 0.758 0.744 0.730 8000 0.788 0.772 0.757 0.743 0.730 0.716 0.703 9000 0.758 0.743 0.729 0.715 0.702 0.689 0.676 10000 0.729 0.715 0.701 0.688 0.676 0.663 0.651 1219 0.916 0.898 0.880 0.864 0.848 0.833 0.817 Altitude (Meter) 1524 0.882 0.864 0.848 0.832 0.817 0.802 0.787 1829 0.849 0.832 0.816 0.801 0.787 0.772 0.758 2134 0.818 0.802 0.787 0.772 0.758 0.744 0.730 2438 0.788 0.772 0.757 0.743 0.730 0.716 0.703 2743 0.758 0.743 0.729 0.715 0.702 0.689 0.676 3048 0.729 0.715 0.701 0.688 0.676 0.663 0.651 Altitude/Temperature Correction Factors Metric Air Temp. C 4.4 10.0 15.5 21.0 26.6 32.0 38.0 0 1.060 1.039 1.019 1.000 0.982 0.964 0.946 305 1.022 1.002 0.982 0.964 0.947 0.929 0.912 610 0.986 0.966 0.948 0.930 0.913 0.897 0.880 914 0.950 0.931 0.913 0.896 0.880 0.864 0.848 1.100 1.050 Correction Factor 1.000 Sea Level 0.950 1000 ft 0.900 2000 ft 0.850 3000 ft 0.800 5000 ft 0.750 6000 ft 7000 ft 4000 ft 8000 ft 0.700 9000 ft 10000 ft 0.650 0.600 40 50 60 70 80 90 100 Air Temperature (ºF) Altitude/Temperature Correction Factors Imperial Johnson Controls Unitary Products 27 1056292-XTG-A-0613 1.100 1.050 Correction Factor 1.000 Sea Level 0.950 305 Meter 0.900 610 Meter 914 Meter 0.850 1219 Meter 0.800 1524 Meter 0.750 1829 Meter 2134 Meter 2430 Meter 0.700 2743 Meter 3048 Meter 0.650 0.600 4.4 10 15.5 21 26.6 Air Temperature (ºC) 32 38 Altitude/Temperature Correction Factors Metric Gas Heat Minimum Supply Air Imperial Supply Air (CFM) Size (Tons) Heat Size 180 (15) 240 (20) 24 32 24 32 Cooling Min 4500 4500 6000 6000 Heating Max 7000 7000 9400 9400 Min 4500 4500 6000 6000 Max 7000 7000 9400 9400 Gas Heat Minimum Supply Air Metric Supply Air (M3/S) Size (Tons) Heat Size 180 (15) 240 (20) 24 32 24 32 Cooling Min 2.13 2.13 2.83 2.83 Heating Max 3.3 3.3 4.44 4.44 Min 2.13 2.13 2.83 2.83 Max 3.3 3.3 4.44 4.44 Electric Heat Minimum Supply Air Imperial Minimum Supply Air (CFM) Size (Tons) Voltage Heater kW 18 36 54 72 180 (15) 380/415-3-50 4500 4500 5000 5000 240 (20) 380/415-3-50 6000 6000 6000 6000 Electric Heat Minimum Supply Air Metric Size (Tons) Voltage 180 (15) 240 (20) 380/415-3-50 380/415-3-50 28 18 2.12 2.83 Minimum Supply Air (M3/S) Heater kW 36 54 2.12 2.36 2.83 2.83 72 2.36 2.83 Johnson Controls Unitary Products 1056292-XTG-A-0613 Indoor Blower Specifications Motor Size (Tons) Model 180 (15) 240 (20) HP RPM Eff. SF ZF 4.0 1450 0.89 1.15 ZF 6.3 1450 0.91 1.15 Motor Sheave Blower Sheave Datum Dia. Datum Dia. Bore (in.) Model Bore (in.) Model Frame (in.) (in.) 184T 4.4 - 5.4 1 1/8 1VP62 6.9 1 BK75 213T 5.8 - 6.8 1 3/8 Motor FLA 2.2 MCA 2.75 1VP75 9.4 1 3/16 BK100 Belt BX68 BX81 Power Exhaust Specifications Voltage Motor RPM1 1075 HP 3/4 460-1-60 QTY 1 LRA 4.1 CFM @ 0.2 ESP 5250 1. Motors are multi-tapped and factory wired for high speed. Electric Heat Multipliers Voltage kW Capacity Multipliers1 Nominal Applied 480 415 0.75 480 380 0.63 1. Electric heaters are rated at nominal voltage. Use this table to determine the electric heat capacity for heaters applied at lower voltages. Sound Performance ZF Indoor Sound Power Levels Size (Tons) CFM 180 (15) 6000 240 (20) 8000 Sound Power, dB (10-12) Watts Blower ESP (IWG) 1 Octave Band Centerline Frequency (Hz) RPM BHP Sound Rating dB (A) 63 125 250 500 1000 2000 4000 1.0 1,080 4.6 91 88 90 90 87 85 81 81 76 1.0 1,020 6.6 86 85 85 83 82 82 78 75 70 8000 1. These values have been accessed using a model of sound propagation from a point source into the hemispheric/free field. The dBA values provided are to be used for reference only. Calculation of dBA values cover matters of system design and the fan manufacturer has no way of knowing the details of each system. This constitutes an exception to any specification or guarantee requiring a dBA value of sound data in any other form than sound power level ratings. ZF Outdoor Sound Power Levels Size (Tons) Sound Rating1 dB (A) 180 (15) 240 (20) Sound Power, dB (10-12) Watts Octave Band Centerline Frequency (Hz) 63 125 250 500 1000 2000 4000 8000 92 90 93 91 89 86 83 80 75 92 91 94 92 89 87 83 81 76 1. Rated in accordance with AHRI 270 standard. Johnson Controls Unitary Products 29 1056292-XTG-A-0613 Electrical Data ZF180 - 240 ZF180-240 - High Static Drive Size (Tons) Compressors (each) Volt RLA C1 C2 LRA C1 C2 MCC C1 C2 OD Fan Motors (each) Supply Blower Motor FLA FLA 380-3-50 18.6 14.5 100.0 90.5 26.0 20.3 2.1 6.3 415-3-50 18.6 14.5 111.0 101.0 26.0 20.3 2.1 6.7 380-3-50 20.7 20.0 110.0 110.0 29.0 28.0 2.1 8.2 415-3-50 20.7 20.0 118.0 118.0 29.0 28.0 2.1 9.1 180 (15) 240 (20) Electric Heat Option Model kW Stages Amps None E18 E36 E54 E72 None E18 E36 E54 E72 None E18 E36 E54 E72 None E18 E36 E54 E72 -11.3 22.6 33.8 45.1 -13.5 26.9 40.0 53.8 -11.3 22.6 33.8 45.1 -13.5 26.9 40.0 53.8 -1 2 2 2 -1 2 2 2 -1 2 2 2 -1 2 2 2 -17.1 34.3 51.4 68.6 -18.7 37.4 56.2 74.9 -17.1 34.3 51.4 68.6 -18.7 37.4 56.2 74.9 MCA1 (Amps) Max Fuse2/ Breaker3 Size (Amps) 49 49 51 73 90 49 49 56 79 84 60 60 60 75 96 60 60 60 82 87 60 60 60 80 100 60 60 60 80 90 70 70 70 80 100 70 70 70 80 90 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. 30 Johnson Controls Unitary Products 1056292-XTG-A-0613 ZF180-240 Wiring Diagrams ZF180-240 Typical Control Diagram THERMOSTAT TERMINALS CONTROL TERMINAL BLOCK W1 W1 W2 1 W2 Y1 Y1 Y2 G 2 OCC P G P1 R Y2 Smoke Detector X C R 4 SD RC OCC X 5 C R 3 SD SD 6 Jumper C 24 VAC Class 2 TERMINALS ON A LIMITED NUMBER OF THERMOSTATS 1 Second stage heating not required on single stage heating units. 2 Second stage cooling not required on single stage cooling units. 3 Jumper is required if there is no Smoke Detector circuit. 4 Jumper is required for any combination of R, RC, or RH. 5 OCC is an output from the thermostat to indicate the Occupied condition. 6 X is an input to the thermostat to display Error Status conditions. Johnson Controls Unitary Products 31 1056292-XTG-A-0613 Weights and Dimensions Y X FRONT LEFT ZF Unit 4 Point Load Weight ZF Unit 6 Point Load Weight B C B D C A A FRONT E ) 80 (1 40) ) 4” 2 (6 9”) ( 4 2 6 16 58 ( 7 1 FRONT D F ZF180-240 Unit Weights Imperial Size (Tons) 180 (15) 240 (20) Model ZF ZF Weight (lbs.) Center of Gravity 4 Point Load Location (lbs.) Shipping Operating X Y A B C D 1685 1680 66.5 45.7 391 443 449 397 2405 2400 70 44 558 590 643 609 6 Point Load Location (lbs.) B C D E 277 302 306 281 382 397 433 417 A 256 369 F 259 402 ZF180-240 Unit Weights Metric Weight (kg.) Center of Gravity (mm) 4 point Load Location (kg.) 6 point Load Location (kg.) Size (Tons) Model 180 (15) ZF 766 764 1689 1161 178 202 204 180 116 126 137 139 128 118 240 (20) ZF 1093 1091 1778 1118 254 268 292 277 168 174 180 197 189 183 Shipping Operating X Y ZF180-240 Unit Accessory Weights Imperial Unit Accessory B C D A B C D E F ZF180-240 Unit Accessory Weights Metric Weight (lbs.) Weight (kg.) Unit Accessory Shipping Operating Economizer 165 160 Economizer 74.8 72.6 Power Exhaust 90 85 Power Exhaust 40.8 40.8 Electric Heat1 40 40 Electric Heat1 18.1 18.1 240 240 Gas Heat2 108.9 108.9 Motorized Damper 150 150 Motorized Damper 68 68 Barometric Damper 50 45 Barometric Damper 22.7 22.7 Gas Heat 2 Shipping Operating Econ./Motorized Damper Rain Hood 60 55 Econ./Motorized Damper Rain Hood 27.2 27.2 Econ./Power Exhaust Rain Hood 95 90 Econ./Power Exhaust Rain Hood 43.1 43.1 Wood Skid 220 220 Wood Skid 99.8 99.8 Roof Curb 190 185 Roof Curb 86.2 86.2 1. Weight given is for the maximum heater size available (54KW). 2. Weight given is for the maximum number of tube heat exchangers available (8 tube). 32 A 1. Weight given is for the maximum heater size available (54KW). 2. Weight given is for the maximum number of tube heat exchangers available (8 tube). Johnson Controls Unitary Products 1056292-XTG-A-0613 Unit Dimensions 1235 (48-5/8") (180) 1337 (52-5/8") (240) 3181 (125-1/4") (180) 3461 (136-1/4") (240) 616 (24-1/4") (180) 895 (35-1/4") (240) RETURN AIR SUPPLY AIR OUTDOOR AIR (Discharge) OUTDOOR AIR (Economizer) Unit Dimensions - ZF Cool & Cool/electric Heat Johnson Controls Unitary Products 33 1056292-XTG-A-0613 1235 (48-5/8") (180) 1337 (52-5/8") (240) 3181 (125-1/4") (180) 3461 (136-1/4") (240) 616 (24-1/4") (180) 895 (35-1/4") (240) RETURN AIR SUPPLY AIR OUTDOOR AIR (Discharge) OUTDOOR AIR (Economizer) Unit Dimensions - ZF Gas Heat 34 Johnson Controls Unitary Products 1056292-XTG-A-0613 Utilities Entry Data HOLE A B OPENING SIZE (DIA.) (MM/IN.) 29/1-1/8” KO 19/3/4” NPS (Fem.) 92/3-5/8” KO 76/3” NPS (Fem.) C 60/2-3/8” KO D 43/1-11/16” Hole USED FOR Side Control Wiring Bottom Side Power Wiring Bottom Gas Piping (Front)1 Gas Piping (Bottom)1, 2 1. One-inch gas piping NPT required. 2. Opening in the bottom of the unit can be located by the slice in the insulation. NOTE: All entry holes should be field sealed to prevent rain water entry into the building. EVAPORATOR SECTION DOT PLUG (For pressure drop reading) 1026 (40-3/8") FILTER ACCESS SUPPLY AIR RETURN AIR COMPRESSOR ACCESS OUTDOOR AIR 1029 (40-1/2") SUPPLY AIR ACCESS Dimensions listed are for side duct flange openings; see Field Accessories for Side Duct Flange Kit. 474 (18-5/8") RETURN AIR ACCESS 130 (5-1/8") REAR VIEW 1" NPT FEMALE COND. DRAIN CONNECTION 705 (27-3/4") ZF180 727 (28-5/8”) ZF240 1006 (39-5/8") OUTDOOR AIR COMPARTMENT ACCESS Rear View Dimensions NOTE: Units are shipped with the bottom duct openings covered. An accessory flange kit is available for connecting side ducts. For bottom duct applications: 1. 2. 3. Remove the side panels from the supply and return air compartments to gain access to the bottom supply and return air duct covers. Remove and discard the bottom duct covers. Duct openings are closed with sheet metal covers except when the unit includes a power exhaust option. The covering consists of a heavy black paper composition. Replace the side supply and return air compartment panels. For side duct applications: 1. Replace the side panels on the supply and return air compartments with the side duct flange accessory kit panels. 2. Connect ductwork to the flanges on those panels. Johnson Controls Unitary Products Minimum Clearances (MM/IN.) LOCATION CLEARANCE Front 914/36” Rear 610/24” (Less Economizer) 1245/49” (With Economizer) Left Side (Filter Access) 610/24” (Less Economizer) 914/36” (With Economizer)3 Right Side (Cond. Coil) 914/36” Below Unit1 0/0” Above Unit2 1829/72” With 914/36” Maximum Horizontal Overhang (For Condenser Air Discharge) 1. Units may be installed on combustible floors made from wood or class A, B, or C roof covering material. 2. Units must be installed outdoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. 3. If economizer is factory installed, the unassembled rain hood must be removed from its ride along position in front of evaporator coil, or in the outdoor air compartment, prior to final installation. 35 1056292-XTG-A-0613 Locate unit so that the vent air outlet hood is at least: NOTE: ELEC / ELEC Models: Units and ductwork are approved for zero clearance to combustible material when equipped with electric heaters. GAS / ELEC Models: A 25mm/1” clearance must be provided between any combustible material and the supply air ductwork for a distance of .9 meter/3 feet from the unit. The products of combustion must not be allowed to accumulate within a confined space and recirculate. SUPPLY AIR COMPARTMENT POWER EXHAUST RAIN HOOD (on Return Air Compartment) ECONOMIZER MOTORIZED DAMPER RAIN HOOD (on Outdoor Air Compartment) • .9 meters/3 feet above any force air inlet located within 3.0 meters/10 horizontal feet (excluding those integral to the unit). • 1.2 meters/4 feet below, four horizontal feet from, or one foot above any door or gravity air inlet into the building. • 1.2 meters/4 feet from electric and gas meters, regulators and relief equipment. ECONOMIZER / MOTORIZED DAMPER AND POWER EXHAUST RAIN HOODS FIXED OUTDOOR AIR INTAKE HOOD (located on Return Air Compartment) 930 (36-5/8”) 25 (1“) CONDENSATE DRAIN (Must be trapped) 410 (16-1/8”) 127 (5”) 716 (28-3/16”) REAR VIEW 2337 (92”) LH VIEW DETAIL “Y” UNIT WITH RAIN HOODS Unit Clearances And Rainhood Dimensions (15 & 20 Ton) 36 Johnson Controls Unitary Products 1056292-XTG-A-0613 * Supply and Return air (including duct support rails) as shown, are typical for Downflow duct applications For location of Sideflow duct applications (on back of unit), refer to Unit Dimension details. Roof Curb Dimensions (All Models) Roof Curb Benefits Johnson Controls Unitary Products Unit Curb And Applications 37 Typical Application Typical Roof-top Installation (Gas/electric Unit Shown) Subject to change without notice. Printed in U.S.A. Copyright © 2014 by Johnson Controls, Inc. All rights reserved. York International Corporation 5005 York Drive Norman, OK 73069 1056292-XTG-A-0613 Supersedes: Nothing
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : clarchd Create Date : 2004:07:21 16:14:32Z Modify Date : 2014:02:13 08:36:38-06:00 Language : en Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Creator Tool : FrameMaker 11.0.2 Metadata Date : 2014:02:13 08:36:38-06:00 Format : application/pdf Title : 1056292-XTG-A-0613.fm Creator : clarchd Producer : Acrobat Distiller 11.0 (Windows) Document ID : uuid:9a6cb2e1-1d4b-4ef0-bbcc-431411ece18b Instance ID : uuid:174f2fb3-0302-49f6-876d-14acb8d4b0f7 Page Mode : UseOutlines Page Count : 38EXIF Metadata provided by EXIF.tools